Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.
Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok
2016-09-01
Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%). Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.
Maternal bradycardia occurring prior to onset of HELLP syndrome in a woman with pre-eclampsia.
Hosokawa, Ami; Umazume, Takeshi; Yamada, Takahiro; Minakami, Hisanori
2017-05-13
A 36-year-old nulliparous woman developed pre-eclampsia at gestational week (GW) 28 -6/7 Cardiac status was checked regularly. Heart rate of 93 beats per minute (bpm) with left atrial diameter (LAD) of 35 mm, left ventricular hypertrophy and inferior vena cava diameter (IVCD) of 8 mm at GW 32 -0/7 decreased to 48 bpm with an expanded IVCD to 25 mm, dilated left atrium (LAD to 39 mm), increased pulmonary arterial pressure, increased systemic vascular resistance (approximate 3000 dyn s/cm 5 ) and biphasic intrarenal venous flow pattern 3.5 hours prior to childbirth at GW 32 -3/7 Epigastralgia, tachycardia (160 bpm) and marked hypertension (201/111 mm Hg) occurring 2 hours after echocardiography necessitated caesarean section, with subsequent development of HELLP syndrome. Acute fluid shift from the splanchnic vasculature to central vasculature may have occurred causing HELLP syndrome as a result from vasospasm associated with sympathetic hyperactivity. The cause of bradycardia prior to tachycardia remains unclear. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Pastore, Gianni; Maines, Massimiliano; Marcantoni, Lina; Zanon, Francesco; Noventa, Franco; Corbucci, Giorgio; Baracca, Enrico; Aggio, Silvio; Picariello, Claudio; Lanza, Daniela; Rigatelli, Gianluca; Carraro, Mauro; Roncon, Loris; Barold, S Serge
2016-12-01
Estimating left ventricular electrical delay (Q-LV) from a 12-lead ECG may be important in evaluating cardiac resynchronization therapy (CRT). The purpose of this study was to assess the impact of Q-LV interval on ECG configuration. One hundred ninety-two consecutive patients undergoing CRT implantation were divided electrocardiographically into 3 groups: left bundle branch block (LBBB), right bundle branch block (RBBB), and nonspecific intraventricular conduction delay (IVCD). The IVCD group was further subdivided into 81 patients with left (L)-IVCD and 15 patients with right (R)-IVCD (resembling RBBB, but without S wave in leads I and aVL). The Q-LV interval in the different groups and the relationship between ECG parameters and the maximum Q-LV interval were analyzed. Patients with LBBB presented a long Q-LV interval (147.7 ± 14.6 ms, all exceeding cutoff value of 110 ms), whereas RBBB patients presented a very short Q-LV interval (75.2 ± 16.3 ms, all <110 ms). Patients with an IVCD displayed a wide range of Q-LV intervals. In L-IVCD, mid-QRS notching/slurring showed the strongest correlation with a longer Q-LV interval, followed, in decreasing order, by QRS duration >150 ms and intrinsicoid deflection >60 ms. Isolated mid-QRS notching/slurring predicted Q-LV interval >110 ms in 68% of patients. The R-IVCD group presented an unexpectedly longer Q-LV interval (127.0 ± 12.5 ms; 13/15 patients had Q-LV >110 ms). Patients with LBBB have a very prolonged Q-LV interval. Mid-QRS notching in lateral leads strongly predicts a longer Q-LV interval in L-IVCD patients. Patients with R-IVCD constitute a subgroup of patients with a long Q-LV interval. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Cinca, Juan; Mendez, Ana; Puig, Teresa; Ferrero, Andreu; Roig, Eulalia; Vazquez, Rafael; Gonzalez-Juanatey, Jose R; Alonso-Pulpon, Luis; Delgado, Juan; Brugada, Josep; Pascual-Figal, Domingo
2013-08-01
Intraventricular conduction defects (IVCDs) can impair prognosis of heart failure (HF), but their specific impact is not well established. This study aimed to analyse the clinical profile and outcomes of HF patients with LBBB, right bundle branch block (RBBB), left anterior fascicular block (LAFB), and no IVCDs. Clinical variables and outcomes after a median follow-up of 21 months were analysed in 1762 patients with chronic HF and LBBB (n = 532), RBBB (n = 134), LAFB (n = 154), and no IVCDs (n = 942). LBBB was associated with more marked LV dilation, depressed LVEF, and mitral valve regurgitation. Patients with RBBB presented overt signs of congestive HF and depressed right ventricular motion. The LAFB group presented intermediate clinical characteristics, and patients with no IVCDs were more often women with less enlarged left ventricles and less depressed LVEF. Death occurred in 332 patients (interannual mortality = 10.8%): cardiovascular in 257, extravascular in 61, and of unknown origin in 14 patients. Cardiac death occurred in 230 (pump failure in 171 and sudden death in 59). An adjusted Cox model showed higher risk of cardiac death and pump failure death in the LBBB and RBBB than in the LAFB and the no IVCD groups. LBBB and RBBB are associated with different clinical profiles and both are independent predictors of increased risk of cardiac death in patients with HF. A more favourable prognosis was observed in patients with LAFB and in those free of IVCDs. Further research in HF patients with RBBB is warranted.
Involvement of DPP IV/CD26 in cutaneous wound healing process in mice.
Baticic Pucar, Lara; Pernjak Pugel, Ester; Detel, Dijana; Varljen, Jadranka
2017-01-01
Dipeptidyl peptidase IV (DPP IV/CD26) is a widely distributed multifunctional protein that plays a significant role in different physiological as well as pathological processes having a broad spectrum of bioactive substrates and immunomodulative properties. It has potential influence on different processes crucial for wound healing, including cell adhesion, migration, apoptosis, and extracellular matrix degradation. However, despite its known enzymatic and immunomodulative functions, limited data characterize the role of DPP IV/CD26 in cutaneous wound healing mechanisms. The aim of this study was to investigate the process of wound healing in conditions of CD26 deficiency in order to obtain better insights on the role of DPP IV/CD26 in cutaneous regeneration. Experimental wounds were made on the dorsal part of CD26 deficient (CD26 -/- ) and wild-type mice (C57BL/6). The process of cutaneous wound healing was monitored on defined time schedule postwounding by macroscopic, microscopic, and biochemical analyses. Obtained results revealed a better rate of wound closure, revascularization and cell proliferation in CD26 -/- mice, with enhanced local expression of hypoxia-inducible factor 1α and vascular endothelial growth factor. CD26 deficiency induced prompt macrophage recruitment at the site of skin damage but did not influence mobilization of T-cells in comparison with wild-type mice. CD26 -/- mice have significantly higher values of IP-10 in serum and control skins compared with wild-type mice but values in wounds did not differ significantly on days 2, 4, and 7 of wound healing. DPP IV/CD26 activity was found to be decreased 4 days postwounding in serum and 2, 4, and 7 days postwounding in wounds of wild-type animals compared with control skins. These findings contribute to better understanding of wound healing mechanisms and could give a support in finding new therapeutic approaches for wound healing and tissue regeneration. © 2016 by the Wound Healing Society.
Persistent left superior vena cava
Tyrak, Kamil W; Hołda, Mateusz K; Koziej, Mateusz; Piątek, Katarzyna; Klimek-Piotrowska, Wiesława
2017-01-01
Summary Persistent left superior vena cava (PLSVC) is the most common congenital malformation of thoracic venous return and is present in 0.3 to 0.5% of individuals in the general population. This heart specimen was dissected from a 35-yearold male cadaver whose cause of death was determined as non-cardiac. The heart was examined and we found a PLSVC draining into the coronary sinus. The right superior vena cava was present with a small-diameter ostium. An anomalous pulmonary vein pattern was observed; there was a common trunk to the left superior and left inferior pulmonary veins (diameter 17.8 mm) and an additional middle right pulmonary vein (diameter 2.7 mm) with two classic right pulmonary veins. The PLSVC draining into the coronary sinus had led to its enlargement, which could have altered the cardiac haemodynamics by significantly reducing the size of the left atrium and impeding its outflow via the mitral valve. PMID:28759082
Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.
Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech
2016-06-01
Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buecker, Arno; Neuerburg, Joerg; Schmitz-Rode, Thomas
1997-11-15
Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombusmore » were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.« less
Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew
2018-05-04
Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.
Lee, Jeong-Won; Seok, Jin Kyung; Boo, Yong Chool
2018-01-01
Airborne particulate matter can cause oxidative stress, inflammation, and premature skin aging. Marine plants such as Ecklonia cava Kjellman contain high amounts of polyphenolic antioxidants. The purpose of this study was to examine the antioxidative effects of E. cava extract in cultured keratinocytes exposed to airborne particulate matter with a diameter of <10 μ m (PM10). After the exposure of cultured HaCaT keratinocytes to PM10 in the absence and presence of E. cava extract and its constituents, cell viability and cellular lipid peroxidation were assessed. The effects of eckol and dieckol on cellular lipid peroxidation and cytokine expression were examined in human epidermal keratinocytes exposed to PM10. The total phenolic content of E. cava extract was the highest among the 50 marine plant extracts examined. The exposure of HaCaT cells to PM10 decreased cell viability and increased lipid peroxidation. The PM10-induced cellular lipid peroxidation was attenuated by E. cava extract and its ethyl acetate fraction. Dieckol more effectively attenuated cellular lipid peroxidation than eckol in both HaCaT cells and human epidermal keratinocytes. Dieckol and eckol attenuated the expression of inflammatory cytokines such as tumor necrosis factor- (TNF-) α , interleukin- (IL-) 1 β , IL-6, and IL-8 in human epidermal keratinocytes stimulated with PM10. This study suggested that the polyphenolic constituents of E. cava , such as dieckol, attenuated the oxidative and inflammatory reactions in skin cells exposed to airborne particulate matter.
Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.
Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek
2003-05-01
Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.
Ultrasound measurement of inferior vena cava diameters by emergency department nurses.
De Lorenzo, Robert A; Holbrook-Emmons, Victoria L
2014-01-01
Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.
Anatomical basis of the liver hanging maneuver.
Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija
2005-01-01
The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).
Ultrasonography of the liver, spleen, and urinary tract of the cheetah (Acinonyx jubatus).
Carstens, Ann; Kirberger, Robert M; Spotswood, Tim; Wagner, Wencke M; Grimbeek, Richard J
2006-01-01
Diseases of the abdomen of the cheetah (Acinonyx jubatus) include those affecting the liver, spleen, and urinary tract. The most common diseases of captive-bred cheetah are gastritis, gastric ulceration, glomerulosclerosis, and hepatic veno-occlusive disease, and are the most frequent causes of mortality in these animals. The purpose of this study was to describe the ultrasonographic anatomy of the normal liver, spleen, kidney, and urinary bladder of the anesthetized captive-bred cheetah. Twenty-one cheetahs were examined. Eight of the 21 animals had subclinical evidence of either gastritis or chronic renal disease. The ultrasonographic appearances of the liver, gall bladder, common bile duct, and spleen were evaluated and various measurements made. Statistical analyses of the measurements were performed on all the healthy and subclinically ill animals taking sex, age, mass, and anesthetic protocol into account. There were no significant differences in any parameters between the healthy and subclinically ill animals (P > 0.25) and data were combined for statistical analyses. The mean mass was 41.1kg ( +/- 8.8) and the mean age was 5.0 years (+/- 2.2). The mean thickness of the liver medial to the gall bladder was 67.0 mm (+/- 14.8) and the liver was within the left costal arch in 75% of animals, extended caudal to the right costal arch in 50% of animals for an average of 30 mm, and extended caudal to the sternum in 63% of animals for an average of 32.5 mm. The maximum mean hepatic vein diameter at the entrance to the caudal vena cava was 8.6 +/- 2.8 mm; the mean diameters of the portal vein at the hilus and that of the caudal vena cava as it entered the liver were 7.5 +/- 1.6 and 9.9 +/- 4.1 mm, respectively. The mean diameter of the caudal vena cava was significantly affected by the type of anesthetic used (P < 0.10). The mass of the animals was significant in explaining the variance in maximum portal vein diameters (P < 0.10). The mean maximum velocity of the hepatic vein flow at the entrance to the caudal vena cava was 25.3 +/- 2.8 cm/s (n=4), the hilar portal vein was 11.7 +/- 3.3 cm/s (n=7), and the caudal vena cava was 33.8 +/- 19.8 cm/s (n=5). The mean maximum gall bladder length and width, and the mean common bile duct diameters were 44.6 mm (+/- 10.4), 23.3 mm (+/- 5.0), and 8.1 mm (+/- 2.4), respectively. Age was significant in explaining the variance in gall bladder lengths (P<0.10). Urinary tract ultrasonography was performed only in animals that had normal urea and creatinine levels (n=13). Renal cortico-medullary distinction was present in all kidneys and a cortico-medullary rim sign was seen in 21 of 26 kidneys. Mean kidney length, height, and width was 63.9 +/- 5.7, 38.1 +/- 5.2, and 42.1 +/- 5 mm, respectively. The average resistivity index was 0.58 (n=5). Mean urinary bladder length, height, and width were 57.0, 19.2, and 34.9 mm, respectively.
Liver hanging maneuver for right hemiliver in situ donation--anatomical considerations.
Trotovsek, B; Gadzijev, E M; Ravnik, D; Hribernik, M
2006-01-01
An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4-6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7+/-3.4 mm and to the entrance of segment 9 veins was 5.0+/-0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7+/-2.3 mm (range 2-15 mm). The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%).
Oiwa, H; Kawauchi, M; Chikada, M; Yagyu, K; Kotsuka, Y; Furuse, A
1995-01-01
A pulsatile total cavopulmonary shunt was successfully performed on a 5-year-old girl with hypoplastic right heart syndrome associated with abnormal systemic venous return; at the same time, modified mitral valve replacement was performed for mitral regurgitation. The right atrium, tricuspid valve and right ventricle were all extremely dimunitive. The diameter of the tricuspid valve was 50% of normal and the volume of the right ventricle was 8.6% of normal. In addition, there were severe subpumonary stenosis, a restrictive ventricular septal defect (VSD) and an atrial septal defect (ASD). The bilateral superior venae cavae (SVCs) and the hepatic vein drained to the left atrium, and the inferior vena cava was infrahepatically interrupted with a hemiazygos connection to the left superior vena cava. At the operation, each SVC was anastomosed end-to-side to each branch of the pulmonary artery (PA). The restrictive ventricular septal defect and stenotic subpulmonary lesion were left. The diameter of the ASD was reduced from 12 mm to 7 mm. The main PA was neither divided nor banded. The pulsatile blood flow from the left heart to the PA was regurated by a native restrictive VSD and stenotic subpulmonary lesion, and that from the right heart via the ASD was limited by reducing the size of the ASD. These described anatomic arrangements produced adequate antegrade pulsatile flow in the PA, which might prevent the development of pulmonary arteriovenous fistulae and, besides permit transfer of drainage of the hepatic vein from the left to the right atrium via the ASD in future.
Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N
2013-09-01
A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.
Liver hanging maneuver for right hemiliver in situ donation – anatomical considerations
Gadžijev, E.M.; Ravnik, D.; Hribernik, M.
2006-01-01
Background. An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4–6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. Materials and methods. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. Results. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7±3.4 mm and to the entrance of segment 9 veins was 5.0±0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7±2.3 mm (range 2–15 mm). Discussion. The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%). PMID:18333236
Flat inferior vena cava: indicator of poor prognosis in trauma and acute care surgery patients.
Ferrada, Paula; Vanguri, Poornima; Anand, Rahul J; Whelan, James; Duane, Therese; Wolfe, Luke; Ivatury, Rao
2012-12-01
Flat inferior vena cava (IVC) on ultrasound examination has been shown to correlate with hypovolemic status. We hypothesize that a flat IVC on limited echocardiogram (LTTE) performed in the emergency room (ER) correlates with poor prognosis in acutely ill surgical patients. We conducted a retrospective review of all patients undergoing LTTE in the ER from September 2010 until June 2011. IVC diameter was estimated by subxiphoid window. Flat IVC was defined as diameter less than 2 cm. Fat IVC was defined as diameter greater than 2 cm. Need for intensive care unit admission, blood transfusion requirement, mortality, and need for emergent operation between patients with flat versus Fat IVC were compared. One hundred one hypotensive patients had LTTE performed in the ER. Average age was 38 years. Admission diagnosis was blunt trauma (n = 80), penetrating trauma (n = 13), acute care surgery pathology (n = 7), and burn (n = 1). Seventy-four patients had flat IVC on initial LTTE. Compared with those with fat IVC, flat patients were found have higher rates of intensive care unit admission (51.3 vs 14.8%; P = 0.001), blood transfusion requirement (12.2 vs 3.7%), and mortality (13.5 vs 3.7%). This population also underwent emergent surgery on hospital Day 1 more often (16.2 vs 0%; P = 0.033). Initial flat IVC on LTTE is an indicator of hypovolemia and a predictor of poor outcome.
Orso, Daniele; Guglielmo, Nicola; Federici, Nicola; Cugini, Francesco; Ban, Alessio; Mearelli, Filippo; Copetti, Roberto
2016-09-01
Dehydration is a very common condition among elderly people. Till date there is not yet a fast and easy method to determine a state of dehydration in the emergency department. In the literature there are some exploratory studies that have tried to establish the relationship between some widely used laboratory values and ultrasound for the purpose of diagnosing dehydration. The primary aim of this study is to verify the correlation between two measures derived by ultrasound (caval index and expiratory diameter of inferior vena cava) and blood urea nitrogen (BUN)/creatinine ratio. The relationship between vital signs and BUN/creatinine ratio has also been explored. An observational cohort study of patients aged 70 years or more, all examined in our ED. The population was divided on the basis of the BUN/creatinine ratio greater or lower than 20. A total of 270 patients have been considered. No vital sign correlated with an increased BUN/creatinine ratio. Both the diameter of the inferior vena cava in expiratory and the percentage of its collapsibility in inspiratory (caval index) have revealed a correlation with a BUN/creatinine ratio greater than 20. Areas under the curve are, respectively, 76 % (95 % CI 70-82) and 80 % (95 % CI 75-86). Sensitivity, specificity, positive predictive value and negative predictive value are, respectively, 85.5 % (95 % CI 79.4-90.4); 100 % (95 % CI 97-100); 100 % (95 % CI 97.5-100); 82.9 % (95 % CI 75.9-88.7) and 99.3 % (95 % CI 96.3-99.9); 100 % (95 % CI 97-100); 100 % (95 % CI 97.5-100); 99.2 % (95 % CI 95.6-99.9). Ultrasound has proved to be useful to diagnose dehydration in elderly people while in the emergency department. Vice versa the vital signs have shown to be unrelated to the hydration state of elderly patients.
Staudenmayer, Herman; Christopher, Kent L; Repsher, Lawrence; Hill, Ronald H
2011-06-01
A multidisciplinary team assessed five patients who alleged chronic medically unexplained multiorgan system symptoms described by idiopathic environmental intolerance allegedly triggered by exposure to solvents used in membrane roofing repair work on an office building. The event precipitated an incident of mass psychogenic illness (MPI). Treating physicians diagnosed irritant-associated vocal cord dysfunction (IVCD) and reactive airways disease syndrome (RADS) resulting from exposure. The authors conducted medical, psychological, and industrial hygiene evaluations. Air monitoring data for total volatile organic compounds obtained during the 2-day exposure period, measurements of emissions during membrane roofing repair at a similar site, mathematical modeling of air contaminant concentrations, and injection of tracer gas into the incident building revealed exposure levels well below those doses anticipated to cause clinical symptoms. There was no objective medical evidence validating symptoms. Review of the medical records indicated that the video laryngoscopy data, pulmonary function tests, and medical examinations relied upon by the treating physicians were inconsistent with published criteria for IVCD and RADS. Psychological evaluation identified defensiveness and self-serving misrepresentations of exaggerated health concerns associated with somatization and malingering. Each case had personality traits associated with at least one personality disorder. Social histories identified premorbid life events and stressors associated with distress. This is the first study to assess psychological predisposition, social interaction among the plaintiffs, and iatrogenic reinforcement of beliefs by diagnoses of pseudo-disorders associated with patient misrepresentation of exaggerated health concerns in an incident of MPI.
Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701
Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.
Liu, Ning; Wang, Zhen; Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei
2016-01-01
To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18-45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis.
Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei
2016-01-01
To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18–45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis. PMID:27893792
Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.
Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R
2018-05-03
Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.
Khanmoradi, Kamran; Defaria, Werviston; Nishida, Seigo; Levi, David; Kato, Tomoaki; Moon, Jang; Selvaggi, Gennaro; Tzakis, Andreas
2009-05-01
We describe our experience with a modification of the piggyback (PB) technique for orthotopic liver transplantation in which the donor infrahepatic vena cava is used as the venous outflow tract. From May 1997 to January 2006, a total of 109 cases using this technique were performed in 101 patients. Collected data included recipient demographics and diagnosis, warm ischemia time, use of venovenous bypass or temporary portacaval shunt and complications related to the venous outflow and graft, and patient survival. Data were compared with the patients undergoing standard PB technique during the same period. The reasons for using the technique were grouped according to whether there was a problem with the recipient hepatic veins or a concern about the length or diameter of the donor suprahepatic vena cava. These included the presence of a transjugular intrahepatic portosystemic shunt (eight cases), retransplantation (22 cases), thin-walled, friable hepatic veins (32 cases), Budd-Chiari syndrome (two cases), domino liver procurement (six cases), reduced or split liver grafts (five cases), and graft inferior vena cava to recipient hepatic veins size discrepancy (34 cases). There was no graft loss. The warm ischemia time was 39.65 minutes compared with 37 minutes in the standard PB group. The long-term graft and patient survival rates were similar in the two groups. Infrahepatic vena cavocavostomy is a useful variation of the standard PB technique.
Inferior Vena Cava Filter Placement and Removal
... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...
Yusof, Mohd Imran; Nadarajan, Eswaran; Abdullah, Mohd Shafie
2014-06-15
Cross-sectional study on the measurement of relevant magnetic resonance imaging parameters in 100 patients presented for lumbar spine assessment. To determine anatomical position of lumbar plexus and major blood vessels in relation to vertebral body and anterior edge of psoas muscle at L3-L4 and L4-L5 and to define the safe working zone for transpsoas approach for lumbar fusion. Lateral transpsoas lumbar interbody fusion has been shown to be safe and provides alternative for lumbar fusion. However, proximity of neurovascular structures may not allow a safe passage for this procedure in the Asian population. Relevant parameters were measured from axial magnetic resonance images and analyzed, including the psoas muscle and vertebrae endplate diameters, lumbar plexus and psoas muscle distance, lumbar plexus and vertebra body distance, and vena cava to the anterior vertebrae body diameters. The mean anteroposterior diameters of the right and left psoas muscle ranged from 44.0 to 58.6 mm and 44.8 to 54.0 mm, respectively. The mean anteroposterior diameters of vertebra endplate of L3, L4, and L5 were 38.2 mm, 39.3 mm, and 41.4 mm, respectively. The mean distance of posterior border of vena cava from the vertebra body was 4.5 mm at L3-L4 and 14.1 mm at L4-L5. L3-L4 fusion is feasible at both sides in both sexes; however, at L4-L5 level, the procedure is feasible only on the left side. The safe working zone for transpsoas approach to lumbar spine is significantly narrower at L4-L5 in both sexes. Anterior edge of psoas muscle can be used as a reliable guide to locate lumbar plexus within psoas muscle. N/A.
[Leiomyosarcoma of the inferior vena cava: a case report and review].
Yo, Toeki; Taoka, Rikiya; Hanasaki, Takeshi; Nakanishi, Yukako; Togo, Yoshikazu; Suzuki, Toru; Higuchi, Yoshihide; Zozumi, Masataka; Hirota, Seiichi; Kanematsu, Akihiro; Nojima, Michio; Yamamoto, Shingo
2014-03-01
A 37-year-old woman with an incidentally found abdominal mass was referred to our hospital. A fixed, non-tender mass was palpated in the right upper quadrum of her abdomen. There was no elevation of tumor markers. Computed tomography revealed a mass extending from the hepatic vein level to renal hilar level. The tumor completely obstructed the inferior vena cava (IVC). T1-weighted magnetic resonance imaging (MRI) showed that the mass was isointense with muscles. T2-weighted MRI image with contrast medium demonstrated collateral circulation. Upon diagnosis of the IVC tumor, we removed the right kidney and the tumor en bloc without reconstructing IVC. The tumor diameter was 11.6 × 5.5 × 4.7 cm. Pathological examination established a diagnosis of IVC leiomyosarcoma. She is alive without sign of recurrence after operation for seven months. There were 143 reports of IVC leiomyosarcoma in Japan. In 31% of them, IVC was not reconstructed.
Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi
2014-09-01
To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr
To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less
Inferior Vena Cava Filter from Left-Sided Superior Vena Cava
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nair, Sujit, E-mail: drsnnair@hotmail.com; Ettles, Duncan; Robinson, Graham
We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.
Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Henshaw, W D; Wang, S L
To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flowmore » in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating/stagnant flow with very low shear stress that may be thrombogenic.« less
Du Plessis, Lodewyk E; Mol, Ben W; Svigos, John M
2016-09-01
Pregnant women with venous thromboembolism are traditionally managed with anticoagulation, but inferior vena cava filters are an alternative. We balanced risks and benefits of an inferior vena cava filter in a decision analysis. We constructed a decision model to compare in pregnant women with VTE the outcome of (1) inferior vena cava filter and anticoagulant treatment versus (2) anticoagulant treatment only. Assuming a 63% risk reduction from an inferior vena cava filter (baseline mortality rate of venous thromboembolism of 0.5%), 318 women would need to be treated with inferior vena cava filters to prevent one venous thromboembolism related maternal death. Sensitivity analyses indicated that at a mortality rate of 0.5% the risk reduction from inferior vena cava filters needed to be 80%, while at a mortality rate of 2% a risk reduction of 20% would justify inferior vena cava filters. In view of their potential morbidity, inferior vena cava filters should be restricted to pregnant woman at strongly increased risk of recurrent venous thromboembolism.
NASA Astrophysics Data System (ADS)
Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent
2013-11-01
A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.
Combat Surgery: Medical Decision Trees for Treatment of Naval Combat Casualties
1991-02-01
inferior vena cava ? NO Is there a hole or tear of left atrium and/or pulmonary veins? NO l ** HEART INJURY ASSESSMENT MODULE T027 2...from holes in either superior or inferior vena cava ? YES NO See Pericardial Vena Cava Injury Module See Bleeding Into Pericardium Module T018...MODULE T018 1/1 Is blood coming from area of superior vena cava ? YES NO See Superior Vena Cava Wound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauter, Alexander; Triller, Juergen; Schmidt, Felix
Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less
Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J
1995-12-01
With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.
Heart Transplant in Patient With Isolated Left Superior Vena Cava by Atrial Appendage Rotation.
Reyes, Karl M; Gupta, Dipankar; Fricker, Frederick Jay; Cooke, Susan; Bleiweis, Mark S
2018-06-01
Orthotopic heart transplantation in patients with an isolated persistent left superior vena cava is extremely rare, and the anastomotic connection between a right-sided donor superior vena cava and left-sided recipient superior vena cava can be challenging to perform. We present a novel technique used in an infant female, using the left atrial appendage to extend the superior vena cava anastomosis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Endovascular management of inferior vena cava filter thrombotic occlusion.
Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R
2018-01-01
Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.
Cho, Y K; Chang, N-K; Ma, J S
2009-05-01
Patent ductus venosus is a rare form of congenital portosystemic shunt from the fetal umbilical vein to the inferior vena cava. The reported surgical treatments include ligation, banding, and liver transplantation. In addition, transcatheter closure with a coil, stent, or original Amplatzer vascular plug (AVP) has been reported. The AVP II, a redesigned version of the original vascular plug with a finer more densely woven nitinol wire and a large diameter (up to 22 mm) is available. This reported case is the first successful occlusion of a large patent ductus venosus with the new AVP II.
Guide wire entrapment by inferior vena cava filters: an experimental study.
Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F
2005-09-01
In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.
Chen, Qiang; Chen, Liang-Wan; Cao, Hua; Zhang, Gui-Can; Chen, Dao-Zhong; Zhang, Hui
2011-03-01
Our objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency. From January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect. The procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001). Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging. Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.
Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William
2018-06-01
The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.
Complications of inferior vena cava filters.
Sella, David M; Oldenburg, W Andrew
2013-03-01
With the introduction of retrievable inferior vena cava filters, the number being placed for protection from pulmonary embolism is steadily increasing. Despite this increased usage, the true incidence of complications associated with inferior vena cava filters is unknown. This article reviews the known complications associated with these filters and suggests recommendations and techniques for inferior vena cava filter removal. Copyright © 2013. Published by Elsevier Inc.
Peachey, Tom; Tang, Andrew; Baker, Elinor C; Pott, Jason; Freund, Yonathan; Harris, Tim
2016-09-02
Assessment of circulating volume and the requirement for fluid replacement are fundamental to resuscitation but remain largely empirical. Passive leg raise (PLR) may determine fluid responders while avoiding potential fluid overload. We hypothesised that inferior vena cava collapse index (IVCCI) and carotid artery blood flow would change predictably in response to PLR, potentially providing a non-invasive tool to assess circulating volume and identifying fluid responsive patients. We conducted a prospective proof of concept pilot study on fasted healthy volunteers. One operator measured IVC diameter during quiet respiration and sniff, and carotid artery flow. Stroke volume (SV) was also measured using suprasternal Doppler. Our primary endpoint was change in IVCCI after PLR. We also studied changes in IVCCI after "sniff", and correlation between carotid artery flow and SV. Passive leg raise was associated with significant reduction in the mean inferior vena cava collapsibility index from 0.24 to 0.17 (p < 0.01). Mean stroke volume increased from 56.0 to 69.2 mL (p < 0.01). There was no significant change in common carotid artery blood flow. Changes in physiology consequent upon passive leg raise normalised rapidly. Passive leg raise is associated with a decrease of IVCCI and increase in stroke volume. However, the wide range of values observed suggests that factors other than circulating volume predominate in determining the proportion of collapse with respiration. In contrast to other studies, we did not find that carotid blood flow increased with passive leg raise. Rapid normalisation of post-PLR physiology may account for this.
Congenital anomalies of the inferior vena cava revealed on CT in patients with deep vein thrombosis.
Gayer, G; Luboshitz, J; Hertz, M; Zissin, R; Thaler, M; Lubetsky, A; Bass, A; Korat, A; Apter, S
2003-03-01
We describe a possible relationship between inferior vena cava anomalies and extensive thrombosis of the inferior vena cava and the iliac and femoral veins. An anomaly of the inferior vena cava should be considered in young patients who present with deep vein thrombosis of the femoral and iliac veins. Coagulation abnormalities, frequently found in these patients, may be a contributory factor.
Lambeir, A M; Durinx, C; Proost, P; Van Damme, J; Scharpé, S; De Meester, I
2001-11-02
Dipeptidyl-peptidase IV (DPPIV/CD26) metabolizes neuropeptides regulating insulin secretion. We studied the in vitro steady-state kinetics of DPPIV/CD26-mediated truncation of vasoactive intestinal peptide (VIP), pituitary adenylyl cyclase-activating peptide (PACAP27 and PACAP38), gastrin-releasing peptide (GRP) and neuropeptide Y (NPY). DPPIV/CD26 sequentially cleaves off two dipeptides of VIP, PACAP27, PACAP38 and GRP. GRP situates between the best DPPIV/CD26 substrates reported, comparable to NPY. Surprisingly, the C-terminal extension of PACAP38, distant from the scissile bond, improves both PACAP38 binding and turnover. Therefore, residues remote from the scissile bond can modulate DPPIV/CD26 substrate selectivity as well as residues flanking it.
Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten
2011-02-01
Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.
The fenestrated Kawashima operation for single ventricle with interrupted inferior vena cava.
Hannan, Robert L; Rossi, Anthony F; Nykanen, David G; Lopez, Leo; Alonso, Francisco; White, Jeffrey A; Burke, Redmond P
2003-01-01
An 8-month-old boy with double outlet right ventricle with hypoplastic left ventricle, heterotaxy, left atrial isomerism, bilateral superior vena cavae without bridging vein, and interruption of the inferior vena cava with azygous continuation to the left superior cava underwent a bilateral bidirectional cavopulmonary anastomosis. A calibrated 3-mm connection between the right pulmonary artery and the common atrium was constructed with the proximal right superior vena cava to allow right to left shunting, analogous to a fenestration in a Fontan operation. We hypothesize that in small young patients undergoing the Kawashima operation a fenestration may improve postoperative hemodynamics.
Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.
Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo
2006-07-01
Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.
Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J
2018-05-01
Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P < .001), and force was distributed at significantly different rates (P < .001) during expansion. The largest radial expansion force at minimal caval diameter was seen in the Cook Platinum filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Chen, Lei; Kim, Yunie; Santucci, Karen A
2007-10-01
Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.
2013-01-01
inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory
Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco
2014-01-01
Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.
Meng, Max
2017-05-01
Level III inferior vena cava tumor thrombectomy for renal cancer is one of the most challenging open urologic surgeries. We present the initial series of completely intracorporeal robotic level III inferior vena cava tumor thrombectomy. Nine patients underwent robotic level III inferior vena cava thrombectomy and 7 patients underwent level II thrombectomy. The entire operation (high intrahepatic inferior vena cava control, caval exclusion, tumor thrombectomy, inferior vena cava repair, radical nephrectomy, and retroperitoneal lymphadenectomy) was performed exclusively robotically. To minimize the chances of intraoperative inferior vena cava thrombus embolization, an "inferior vena cava-first, kidney-last" robotic technique was developed. Data were accrued prospectively. All 16 robotic procedures were successful, without open conversion or mortality. For level III cases (9), median primary kidney (right 6, left 3) cancer size was 8.5cm (range: 5.3-10.8) and inferior vena cava thrombus length was 5.7cm (range: 4-7). Median operative time was 4.9 hours (range: 4.5-6.3), estimated blood loss was 375ml (range: 200-7,000), and hospital stay was 4.5 days. All surgical margins were negative. There were no intraoperative complications and 1 postoperative complication (Clavien 3b). At a median 7 months of follow-up (range: 1-18) all patients are alive. Compared to level II thrombi the level III cohort trended toward greater inferior vena cava thrombus length (3.3 vs 5.7cm), operative time (4.5 vs 4.9h) and blood loss (290 vs 375ml). With appropriate patient selection, surgical planning and robotic experience, completely intracorporeal robotic level III inferior vena cava thrombectomy is feasible and can be performed efficiently. Larger experience, longer follow-up and comparison with open surgery are needed to confirm these initial outcomes. Copyright © 2017. Published by Elsevier Inc.
Wiles, H B
1991-01-01
The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125
Ecklonia cava promotes hair growth.
Bak, S S; Ahn, B N; Kim, J A; Shin, S H; Kim, J C; Kim, M K; Sung, Y K; Kim, S K
2013-12-01
Previous studies have reported the protective effects on skin elasticity of the edible marine seaweed Ecklonia cava, which acts through regulation of both antioxidative and anti-inflammatory responses. We evaluated the effect of E. cava and one of its components, dioxinodehydroeckol, on hair-shaft growth in cultured human hair follicles and on hair growth in mice. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to check cell viability of human dermal papilla cells (DPCs) and outer root sheath (ORS) cells after treatment with E. cava and its metabolite, dioxinodehydroeckol. Hair-shaft growth was measured using the in vitro hair-follicle organ-culture system, in the presence or absence of E. cava and dioxinodehydroeckol. Anagen induction activity was examined by topical application of E. cava to the dorsal skin of C57BL/6 mice. Insulin-like growth factor (IGF)-1 expression was measured by reverse transcriptase PCR and ELISA. The proliferation activity was found to be highest for the ethyl acetate-soluble fraction of E. cava (EAFE) in DPCs and in ORS cells. Treatment with EAFE resulted in elongation of the hair shaft in cultured human hair follicles, and promoted transition of the hair cycle from the telogen to the anagen phase in the dorsal skin of C57BL/6 mice. In addition, EAFE induced an increase in IGF-1 expression in DPCs. Dioxinodehydroeckol, a component of E. cava, induced elongation of the hair shaft, an increase in proliferation of DPCs and ORS cells, and an increase in expression of IGF-1 in DPCs. These results suggest that E. cava containing dioxinodehydroeckol promotes hair growth through stimulation of DPCs and ORS cells. © 2013 British Association of Dermatologists.
Ramman, Tarun Raina; Dutta, Nilanjan; Chowdhuri, Kuntal Roy; Agrawal, Sunny; Girotra, Sumir; Azad, Sushil; Radhakrishnan, Sitaraman; Iyer, Parvathi Unninayar; Iyer, Krishna Subramony
2018-01-01
Persistent left superior vena cava is a common congenital anomaly of the thoracic venous system. Left superior vena cava draining into left atrium is a malformation of sinus venosus and caval system. The anomaly may be a cause of unexplained hypoxia even in adults. It may give rise to various diagnostic and technical challenges during cardiac catheterization and open-heart surgery. It is often detected serendipitously during diagnostic workup. Isolated left superior vena cava opening into left atrium is very commonly associated with other congenital heart defects. But tetralogy of Fallot is very rarely associated with persistent left superior vena cava which drains into left atrium. We report four such cases who underwent surgical correction successfully.
Impact of Chronic Rheumatic Valve Diseases on Large Vessels.
Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet
2016-01-01
BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.
Cross-sectional echocardiographic diagnosis of azygos continuation of the inferior vena cava.
Huhta, J C; Smallhorn, J F; Macartney, F J
1984-01-01
Azygos continuation of the inferior vena cava has importance for both the invasive diagnosis of congenital heart disease by catheterization and for surgical treatment. Cross-sectional echocardiography was used to examine 1,000 patients (1 day to 16 years, mean 3.3 years) who also had angiographic or surgical confirmation. Twenty-eight patients (3%) had azygos continuation (left 13, right 14, bilateral 1) and, in 26 patients, the hepatic portion of the inferior vena cava was absent. Azygos continuation was prospectively detected in all and was directly visualized in subcostal scans as a venous structure posterior to the aorta coursing behind the heart and not entering the inferior aspect of either atrium in 26/28 (93%). Azygos connection to the ipsilateral superior vena cava or atrium was correctly predicted in all. The inferior vena cava was visualized in all patients without azygos continuation, except one neonate with omphalocele. We conclude that cross-sectional echocardiography can accurately detect azygos continuation of the inferior vena cava and predict its side and connection.
Cross-sectional echocardiographic diagnosis of systemic venous return.
Huhta, J C; Smallhorn, J F; Macartney, F J; Anderson, R H; de Leval, M
1982-01-01
To determine the sensitivity and specificity of cross-sectional echocardiography in diagnosing anomalous systemic venous return we used the technique in 800 consecutive children with congenital heart disease and whom the diagnosis was ultimately confirmed by angiography. Cross-sectional echocardiography was performed without prior knowledge of the diagnosis in all but 11 patients, who were recalled because of a known abnormality of atrial situs. The sensitivity of cross-sectional echocardiographic detection of various structures was as follows: right superior vena cava 792/792 (100%); left superior vena cava 46/48 (96%); bilateral superior vena cava 38/40 (95%); bridging innominate vein with bilateral superior vena cava 13/18 (72%); connection of superior caval segment to heart (coronary sinus or either atrium) (100%); absence of suprarenal inferior vena cava 23/23 (100%); azygos continuation of the inferior vena cava 31/33 (91%); downstream connection of azygos continuation, once seen, 21/21 (100%); partial anomalous hepatic venous connection (one hepatic vein not connected to the inferior vena cava) 1/1 (100%); total anomalous hepatic venous connection (invariably associated with left isomerism) 23/23 (100%). The specificity of each above diagnoses was 100% except in one infant with exomphalos in whom absence of the suprarenal inferior vena cava was incorrectly diagnosed. Thus cross-sectional echocardiography is an extremely specific and highly sensitive method of recognizing anomalous systemic venous return. It is therefore of great value of planning both cardiac catheterisation and cannulation for open heart surgery. Images PMID:6751361
Charbonneau, Hélène; Riu, Béatrice; Faron, Matthieu; Mari, Arnaud; Kurrek, Matt M; Ruiz, Jean; Geeraerts, Thomas; Fourcade, Olivier; Genestal, Michèle; Silva, Stein
2014-09-05
Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients. Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%). Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity. ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veerapong, Jula; Wahlgren, Carl Magnus, E-mail: carl.wahlgren@karolinska.s; Jolly, Neeraj
The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.
1999-04-01
atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava
LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING
2015-01-01
The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424
Innervation of the sinu-atrial node and neighbouring regions in two human embryos.
Orts Llorca, F; Domenech Mateu, J M; Puerta Fonolla, J
1979-01-01
In human embryos of 20 to 23 mm (36 to 40 days) it is possible to identify on the right side a nerve that we may call the sinusal, which originates by several roots from the nervus vagus dexter (Figs. 1A, B, D), descending through the right ventrolateral face of the primary trachea and right bronchus (Fig. 2, arrows). Beaded in appearance, it gives a fine anastomotic branch which, passing in front of the arteria pulmonalis dextra, passes to the left side (Figs. 2B, C, D; AN). At this level it gives the large branch for the nodus sinoatrialis which, penetrating through the wall of the superior vena cava, provides a rich innervation for the nodus sinoatrialis which is already in an advanced stage of differentiation (Fig. 3, 2; Cy, D, AN). Afterwards it gives fine branches which, following the atrial fold, are distributed throughout the posterior face of the atrium dextrum (Fig. 3). It increases in diameter and, passing through the angle formed by the right pulmonary veins with the atrium dextrum, reaches the intrapericardial portion of the inferior vena cava in the vicinity of its outlet from the atrium (Fig. 3, arrows). The whole innervation is parasympathetic at the stages studied. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:438095
Anomalies of the systemic venous return: a review.
Mazzucco, A; Bortolotti, U; Stellin, G; Gallucci, V
1990-06-01
Congenital anomalies of the systemic venous connection to the heart represent a rather wide and heterogeneous group of malformations, whose physiological consequences may vary from nil to the most severe form of systemic arterial desaturation. The malformations may be summarized as follows: (1) Left superior vena cava connected to the coronary sinus, interrupted inferior vena cava and absent right superior vena cava that do not indicate surgical repair 'per se', but require some technical attention during open heart surgery performed for other anomalies; (2) Left superior vena cava connected to the left atrium, due to incorporation of the coronary sinus into the left atrial cavity, resulting in a right-to-left-shunt; (3) Right superior vena cava or inferior vena cava draining into the left atrium, both are extremely rare and require treatment for the ensuing right-to-left shunt; (4) Total anomalous systemic venous connection to the left atrium, usually combined with atrial isomerism and other very complex heart malformations; (5) Cor triatriatum dexter, which has been frequently diagnosed as an anomalous venous connection for its similar hemodynamic consequences. Such anomalies are reviewed with particular respect to their surgical implications.
Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.
Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel
2015-12-01
We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.
Unusual presentation of total anomalous systemic venous connection.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Pradhan, Priya M; Agarwal, Ravi
2017-07-01
A 9-year-old girl who presented with dyspnea on exertion was diagnosed with total anomalous systemic venous connection to the left atrium (both venae cavae), no left superior vena cava, and a moderate-sized atrial septal defect with severe pulmonary arterial hypertension and ectopic atrial rhythm. She underwent septation of the common atrium using autologous pericardium, thereby rerouting the superior vena cava, inferior vena cava, and coronary sinus to the right atrium. Her postoperative course was uneventful. This case is reported for its rarity of presentation with severe pulmonary arterial hypertension and ectopic atrial rhythm.
NASA Astrophysics Data System (ADS)
Pan, Boan; Liu, Weichao; Fang, Xiang; Zhao, Ke; Li, Ting
2018-02-01
Deep vein thrombosis (DVT), happening in inpatients usually and especially with the postoperative population, is a serious disease characterized by an increased incidence. The venography is the golden standard to diagnose DVT. However, it involves invasive contrast agent injection and give patients physical and mental pressure. Functional nearinfrared spectroscopy (fNIRS) has been reported recently to diagnose DVT. Thrombolytic therapy activates the dissolution system with an exogenous activator that dissolves coronary thrombosis. The vena cava filter is a medical filter used for the treatment of thrombosis and the prevention of pulmonary embolism. Here we attempt to use portable NIRS for the DVT monitoring in the whole process of vena cava filter implantation and thrombolytic treatment, and contrast the patients of untreated, vena cava filter implantation and thrombolytic treatment. 19 DVT patients and 12 normal subjects were recruited. Thereinto, 7 patients have taken vena cava filter implantation, and 6 patients have taken the thrombolytic treatment. It was found that deoxyhemoglobins (Δ[Hb]) fluctuates and even increases in DVT. After vena cava filter implantation, Δ[Hb] increases first, then decreases. However, it emerges the rising trend and converge to the curves of normal subjects in thrombolytic treatment. The oxyhemoglobins (Δ[HbO2]) emerges opposite trend in most paradigms. The findings reveal the potential of fNIRS for monitoring DVT and therapeutic effect evaluation of thrombolysis and vena cava filters.
Kaul, D K; Roth, E F; Nagel, R L; Howard, R J; Handunnetti, S M
1991-08-01
The occurrence of rosetting of Plasmodium falciparum-infected human red blood cells (IRBC) with uninfected red blood cells (RBC) and its potential pathophysiologic consequences were investigated under flow conditions using the perfused rat mesocecum vasculature. Perfusion experiments were performed using two knobby (K+) lines of P falciparum, ie, rosetting positive (K+R+) and rosetting negative (K+R-). The infusion of K+R+ IRBC resulted in higher peripheral resistance (PRU) than K+R- IRBC (P less than .0012). Video microscopy showed that under conditions of flow, in addition to cytoadherence of K+R+ IRBC to the venular endothelium, rosette formation was also restricted to venules, especially in the areas of slow flow. Rosettes were absent in arterioles and were presumably dissociated by higher wall shear rates. The presence of rosettes in the venules must therefore reflect their rapid reformation after disruption. Cytoadherence of K+R+ IRBC was characterized by formation of focal clusters along the venular wall. In addition, large aggregates of RBC were frequently observed at venular junctions, probably as a result of interaction between flowing rosettes, free IRBC, and uninfected RBC. In contrast, the infusion of K+R+ IRBC resulted in diffuse cytoadherence of these cells exclusively to the venular endothelium but not in rosetting or large aggregate formation. The cytoadherence of K+R+ IRBC showed strong inverse correlation with the venular diameter (r = -.856, P less than .00001). Incubation of K+R+ IRBC with heparin and with monoclonal antibodies to glycoprotein IV/CD36 abolished the rosette formation and resulted in decreased PRU and microvascular blockage. These findings demonstrate that rosetting of K+R+ IRBC with uninfected RBC enhances vasocclusion, suggesting an important in vivo role for rosetting in the microvascular sequestration of P falciparum-infected RBC.
Course of the inferior vena cava on lateral films exposed in different positions.
Lien, H H; Bakke, S J
1981-01-01
The distance from the posterior border of the inferior vena cava to the anterior vertebral margin was measured in 100 presumably normal patients in the supine position. Seventeen of these were also examined in the right and left lateral positions and the changes in course of the vena cava compared with the supine position.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz
2009-05-01
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less
A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions
Montgomery, Jennifer P.; Kaufman, John A.
2016-01-01
Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration. PMID:27247475
A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions.
Montgomery, Jennifer P; Kaufman, John A
2016-06-01
Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration.
Jiang, Jun; Jiao, Yuanyong; Zhang, Xiwei
2017-10-01
Objectives To perform a meta-analysis of randomized controlled trials assessing the effectiveness of inferior vena cava filters in patients with deep vein thrombosis for preventing pulmonary embolism. Method Relevant randomized controlled trials of inferior vena cava filters for the prevention of pulmonary embolism were identified by searching electronic databases updated in February 2016. Relative risks of recurrent pulmonary embolism, recurrent deep vein thrombosis, and mortality at three months were analyzed. Results Three published randomized controlled trials were included involving a total of 863 deep vein thrombosis patients. No significant differences were detected with inferior vena cava filters placement with regard to the incidence of recurrent pulmonary embolism or fatal pulmonary embolism. There were also no significant differences in the incidence of recurrent deep vein thrombosis or mortality with inferior vena cava filters placement at three months. Conclusions Inferior vena cava filter in addition to anticoagulation was not associated with a reduction in the incidence of recurrent pulmonary embolism as compared with anticoagulation alone in patients with deep vein thrombosis in the short term.
Zhou, Yu-Qing; Cahill, Lindsay S; Wong, Michael D; Seed, Mike; Macgowan, Christopher K; Sled, John G
2014-08-15
This study used high-frequency ultrasound to evaluate the flow distribution in the mouse fetal circulation at late gestation. We studied 12 fetuses (embryonic day 17.5) from 12 pregnant CD1 mice with 40 MHz ultrasound to assess the flow in 11 vessels based on Doppler measurements of blood velocity and M-mode measurements of diameter. Specifically, the intrahepatic umbilical vein (UVIH), ductus venosus (DV), foramen ovale (FO), ascending aorta (AA), main pulmonary artery (MPA), ductus arteriosus (DA), descending thoracic aorta (DTA), common carotid artery (CCA), inferior vena cava (IVC), and right and left superior vena cavae (RSVC, LSVC) were examined, and anatomically confirmed by micro-CT. The mouse fetal circulatory system was found to be similar to that of the humans in terms of the major circuit and three shunts, but characterized by bilateral superior vena cavae and a single umbilical artery. The combined cardiac output (CCO) was 1.22 ± 0.05 ml/min, with the left ventricle (flow in AA) contributing 47.8 ± 2.3% and the right ventricle (flow in MPA) 52.2 ± 2.3%. Relative to the CCO, the flow percentages were 13.6 ± 1.0% for the UVIH, 10.4 ± 1.1% for the DV, 35.6 ± 2.4% for the DA, 41.9 ± 2.6% for the DTA, 3.8 ± 0.3% for the CCA, 29.5 ± 2.2% for the IVC, 12.7 ± 1.0% for the RSVC, and 9.9 ± 0.9% for the LSVC. The calculated flow percentage was 16.6 ± 3.4% for the pulmonary circulation and 31.2 ± 5.3% for the FO. In conclusion, the flow in mouse fetal circulation can be comprehensively evaluated with ultrasound. The baseline data of the flow distribution in normal mouse fetus serve as the reference range for future studies. Copyright © 2014 the American Physiological Society.
Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.
Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F
2003-11-01
To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.
Indications, complications and outcomes of inferior vena cava filters: A retrospective study.
Wassef, Andrew; Lim, Wendy; Wu, Cynthia
2017-05-01
Inferior vena cava filters are used to prevent embolization of a lower extremity deep vein thrombosis when the risk of pulmonary embolism is thought to be high. However, evidence is lacking for their benefit and guidelines differ on the recommended indications for filter insertion. The study aim was to determine the reasons for inferior vena cava filter placement and subsequent complication rate. A retrospective cohort of patients receiving inferior vena cava filters in Edmonton, Alberta, Canada from 2007 to 2011. Main outcome was the indication of inferior vena cava filter insertion. Other measures include baseline demographic and medical history of patients, clinical outcomes and filter retrieval rates. 464 patients received inferior vena cava filters. An acute deep vein thrombosis with a contraindication to anticoagulation was the indication for 206 (44.4%) filter insertions. No contraindication to anticoagulation could be identified in 20.7% of filter placements. 30.6% were placed in those with active cancer, in which mortality was significantly higher. Only 38.9% of retrievable filters were successfully retrieved. Inferior vena cava filters were placed frequently in patients with weak or no guideline-supported indications for filter placement and in up to 20% of patients with no contraindication to anticoagulation. The high rates of cancer and the high mortality rate of the cohort raise the possibility that some filters are placed inappropriately in end of life settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
1995 Toxic Hazards Research Unit Annual Report.
1996-07-01
cabinet, the bile duct is cannulated using PE-10 tubing, the portal vein and inferior vena cava (above the diaphragm) are both cannulated with 16...homogenate in saline. Rats used to determine partition coefficients were euthanatized with C02. Blood was collected from the posterior vena cava ...sampled for histopathologic examination. Blood was sampled via the vena cava for clinical chemistry evaluations and whole livers were weighed at
Non-Invasive Methods of Cardiovascular Exploration in Aerospace Medicine.
1983-12-01
inferior vena cava Aorta right atrium filling chamber of right ventricle. Trunk of pulmonary art cry Posterior border: almost vertical AP lower arch left ... left ventricle. Inferior Vena cava infundihbulum L Upper border aortic arch Lower border superimposed borders of the RV LV right and left ventricles...iliac aneurisms is possible. isotopic phlebography is useful in the investigation of the permeability of the inferior vena cava
Baggett, Charles; Skeen, Shawn J.; Gantt, D. Scott; Trotter, Bradley R.; Birkemeier, Krista L.
2009-01-01
Isolated right superior vena cava drainage into the left atrium is an extremely rare cardiac anomaly, especially in the absence of other cardiac abnormalities. Only 28 of 5,127 reported consecutive congenital cardiac cases involved superior vena cava drainage into the left atrium, and all were associated with other cardiac anomalies. Of 19 reported cases of right superior vena cava drainage into the left atrium, most patients have been children who were experiencing mild hypoxemia and cyanosis. Herein, we describe the case of a 34-year-old woman who presented with asymptomatic hypoxemia in the peripartum period. She was diagnosed to have isolated drainage of the right superior vena cava into the left atrium. To the best of our knowledge, this is the 1st reported instance of such diagnosis by use of noninvasive imaging only, without cardiac catheterization. We also review the medical literature that pertains to our patient's anomaly. PMID:20069093
Wijesinghe, W A J P; Jeon, You-Jin
2012-03-01
Seaweeds are rich in vitamins, minerals, dietary fibres, proteins, polysaccharides and various functional polyphenols. Many researchers have focused on brown algae as a potential source of bioactive materials in the past few decades. Ecklonia cava is a brown seaweed that is abundant in the subtidal regions of Jeju Island in the Republic of Korea. This seaweed attracted extensive interest due to its multiple biological activities. E. cava has been identified as a potential producer of wide spectrum of natural substances such as carotenoids, fucoidans and phlorotannins showing different biological activities in vital industrial applications including pharmaceutical, nutraceutical, cosmeceutical and functional food. This review focuses on biological activities of the brown seaweed E. cava based on latest research results, including antioxidant, anticoagulative, antimicrobial, antihuman immunodeficiency virus, anti-inflammatory, immunomodulatory, antimutagenic, antitumour and anticancer effects. The facts summarized here may provide novel insights into the functions of E. cava and its derivatives and potentially enable their use as functional ingredients in potential industrial applications.
NASA Technical Reports Server (NTRS)
Schrier, R. W.; Humphreys, M. H.; Ufferman, R. C.
1971-01-01
Study of the differential characteristics of hepatic congestion and decreased cardiac output in terms of potential afferent stimuli in the antinatriuretic effect of acute thoracic inferior vena cava (TIVC) constriction. An attempt is made to see if the autonomic nervous system is involved in the antinatriuretic effect of acute TIVC or thoracic superior vena cava constriction.
Liu, Yunqi; Liu, Yanqiu; Xiong, Mai; Li, Hanzhao; Liu, Donghong; Zhang, Xi
2017-04-01
The left circumflex coronary artery associated with a fistula to superior vena cava is a rare entity. We describe a 7-year-old girl who presented with a cardiac murmur and was diagnosed with a coronary artery fistula between the left circumflex artery and superior vena cava by echocardiography. The surgical occlusion of the fistula was successful. © 2017, Wiley Periodicals, Inc.
Boutayeb, Alaae; Marmade, Lahcen; Bensouda, Adil; Moughil, Said
2012-01-01
The left superior vena cava is the most common congenital venous anomaly in the chest; however, its drainage into the left atrium is exceptional. The aim of the paper is to describe our novel technique to connect the left superior vena cava to the right cavities using the left atrial appendage, without cardiopulmonary bypass. PMID:22802356
Annual Progress Report Fiscal Year 1989
1989-09-30
thopaedics, Las Vegas, NV, February, 1989 clusion of the common iliac veins and inferior vena cava H following vaginal hysterectomy. A case report...The aorta and inferior vena cava will be transected and cannulated. Using techniques prescribed in the Microill product literature the aorta and both...via the inferior vena cava . At that point the animals will be refrigerated to allow overnight curing of the Microfil. As each animal has had only one
The Use of Hypertonic Solutions to Resuscitate Animals from Hypovolemic Shock.
1986-03-18
halothane/nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed...and on skeletal muscle inferior vena cava . Heart rate was recorded resting transmembrane potentials. These ef- and blood press.ure was monitored with...nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed through a
Radical robot-assisted laparoscopic nephrectomy with thrombectomy in the vena cava.
Estébanez Zarranz, J; Belloso Loidi, J; Gutierrez García, M A; Rubio Calaveras, V; Morales Higelmo, G; Melendo Tercilla, P; Busto Leis, L; Sanz Jaka, J P
2018-04-23
Renal cell carcinoma has a natural tendency to extend through the renal vein. When the thrombus reaches the vena cava, thrombectomy and the necessary reconstruction of the vena cava are typically performed by open pathway. Robot-assisted technology provides advantages for performing this complex technique, using a minimally invasive access. We present the technique we employed in the first case performed in our department. After performing renal artery embolisation, we conducted the surgery with the Vinci S robotic system. The main steps of the surgery are as follows: detachment and Kocher manoeuvre; release of the lower renal pole; clamping and sectioning of the renal artery; endocavitary ultrasound to locate the thrombus; placement of tourniquets in the vena cava below and above the renal veins and in the left renal vein; closure of the 3 tourniquets; opening of the vena cava; resection and extraction of the thrombus; suture of the vena cava; opening of the tourniquets; complete release of the kidney; bagging and extraction of the specimen. The surgery was performed without complications. The patient required a transfusion of 2 units of packed red blood cells and was discharged with modest renal failure (creatinine level of 1.60mg/dl). Radical nephrectomy with thrombectomy in the vena cava is a technique susceptible to severe complications and has, to date, been performed in few centres. We believe that the technique is reproducible and has clear advantages for our patients. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Choi, Yohan; Hosseindoust, Abdolreza; Goel, Akshat; Lee, Suhyup; Jha, Pawan Kumar; Kwon, Ill Kyong; Chae, Byung-Jo
2017-01-01
In the present study, role of increasing levels of Ecklonia cava (seaweed) supplementation in diets was investigated on growth performance, coefficient of total tract apparent digestibility (CTTAD) of nutrients, serum immunoglobulins, cecal microflora and intestinal morphology of weanling pigs. A total of 200 weaned pigs (Landrace×Yorkshire×Duroc; initial body weight 7.08±0.15 kg) were randomly allotted to 4 treatments on the basis of body weight. There were 5 replicate pens in each treatment including 10 pigs of each. Treatments were divided by dietary Ecklonia cava supplementation levels (0%, 0.05%, 0.1%, or 0.15%) in growing-finishing diets. There were 2 diet formulation phases throughout the experiment. The pigs were offered the diets ad libitum for the entire period of experiment in meal form. The pigs fed with increasing dietary concentrations of Ecklonia cava had linear increase (p<0.05) in the overall average daily gain, however, there were no significant differences in gain to feed ratio, CTTAD of dry matter and crude protein at both phase I and phase II. Digestibility of gross energy was linearly improved (p<0.05) in phase II. At day 28, pigs fed Ecklonia cava had greater (linear, p<0.05) Lactobacillus spp., fewer Escherichia coli ( E. coli ) spp. (linear, p<0.05) and a tendency to have fewer cecal Clostridium spp. (p = 0.077). The total anaerobic bacteria were not affected with supplementation of Ecklonia cava in diets. Polynomial contrasts analysis revealed that villus height of the ileum exhibited a linear increase (p<0.05) in response with the increase in the level of dietary Ecklonia cava . However, villus height of duodenum and jejunum, crypt depth, villus height to crypt depth ratio of different segments of the intestine were not affected. The results suggest that Ecklonia cava had beneficial effects on the growth performance, cecal microflora, and intestinal morphology of weanling pigs.
Prognostic significance of dilated inferior vena cava in advanced decompensated heart failure.
Lee, Hsin-Fu; Hsu, Lung-An; Chang, Chi-Jen; Chan, Yi-Hsin; Wang, Chun-Li; Ho, Wan-Jing; Chu, Pao-Hsien
2014-10-01
Dilated inferior vena cava (IVC) is prevalent among patients with heart failure (HF), but whether its presence predicts worsening renal function (WRF) or adverse outcomes is unclear. This cohort study analyzed patients with left ventricular ejection fraction <40 % and repeated hospitalizations (≥2 times) for HF between August 2009 and August 2011. The study endpoints were death and HF re-hospitalization. Among baseline parameters, IVC diameter was the most powerful predictor for the development of WRF (area under the curve = 0.795, cut-off value = 20.5 mm). During the 2-year follow-up, 36 patients (49 %) were re-hospitalized for HF and 14 patients (19 %) died. The event rates were significantly greater in the WRF group than in the non-WRF group (71 vs. 30 %, P < 0.001 for HF re-hospitalization; 29 vs. 10 %, P = 0.03 for death). In Cox regression model, the risk of combined end-points was increased in patients with aging, elevated blood urine nitrogen, IVC >21 mm, and WRF. When adjusted for confounding factors, IVC >21 mm [hazard ratio (HR) 3.73, 95 % confidence interval (CI) 1.66-8.34] and WRF (HR 2.68, 95 % CI 1.07-6.75) were significant predictors for adverse outcomes. In patients with advanced decompensated HF, dilated IVC (>21 mm) predicted the development of WRF and could be a predictor for adverse outcomes.
Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati
2018-02-26
The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P < .0001; aorta, r = 0.82-0.86; P < .0001). In children younger than 6 years, the IVC and aorta increase linearly as the children grow. Such normal curves will be beneficial for assessing a pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.
Vena caval impalement: an unusual lawn mower injury in a child.
Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P
1998-06-01
Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.
Design Optimization of Vena Cava Filters: An application to dual filtration devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Wang, S L; Diachin, D P
Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped modelmore » thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.« less
Richardson, James V.; Doty, Donald B.
1979-03-01
This report describes a rare case of isolated anomalous connection of the inferior vena cava to the left atrium. Patching of a surgically-created atrial septal defect and rerouting of caval drainage ino the right atrium effected a successful correction. This case brings to 18 the total number of reported cases in the literature in which the inferior vena cava was connected to the left atrium.
Clinical Investigation Program.
1979-10-01
It has been established by a series of dog experiments using the-e-e-ctromagnetic flow meter that the blood flow in the inferior vena cava between...by thermodilution. Hepatic vein blood flow could be estimated by subtraction of the blood flow in the vena cava at the level of the renal veins from...the vena cava blood flow at the level of the diaphragm. This should be liver blood flow. It should be possible to sample pure hepatic vein blood by
2001-10-25
a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV
Cardiac Ischemia Model for +Gz Using Miniature Swine and Baboons
2008-04-01
VAP was tunneled subcutaneously to an incision in the ventral neck and placed in the superior vena cava just craniad to the right atrium through...was passed transcutaneously to the su- perior vena cava from the arm or to the inferior vena cava from the lower leg, using fl uoroscopy. The...Five control swine were maintained on a standard swine diet. Also, nine male baboons had a constrictor placed around the left anterior descending
Structural and Functional Differences Between Porcine Aorta and Vena Cava.
Mattson, Jeffrey M; Zhang, Yanhang
2017-07-01
Elastin and collagen fibers are the major load-bearing extracellular matrix (ECM) constituents of the vascular wall. Arteries function differently than veins in the circulatory system; however as a result from several treatment options, veins are subjected to sudden elevated arterial pressure. It is thus important to recognize the fundamental structure and function differences between a vein and an artery. Our research compared the relationship between biaxial mechanical function and ECM structure of porcine thoracic aorta and inferior vena cava. Our study suggests that aorta contains slightly more elastin than collagen due to the cyclical extensibility, but vena cava contains almost four times more collagen than elastin to maintain integrity. Furthermore, multiphoton imaging of vena cava showed longitudinally oriented elastin and circumferentially oriented collagen that is recruited at supraphysiologic stress, but low levels of strain. However in aorta, elastin is distributed uniformly, and the primarily circumferentially oriented collagen is recruited at higher levels of strain than vena cava. These structural observations support the functional finding that vena cava is highly anisotropic with the longitude being more compliant and the circumference stiffening substantially at low levels of strain. Overall, our research demonstrates that fiber distributions and recruitment should be considered in addition to relative collagen and elastin contents. Also, the importance of accounting for the structural and functional differences between arteries and veins should be taken into account when considering disease treatment options.
Inferior Vena Cava Filters in Patients with Acute Pulmonary Embolism and Cancer.
Stein, Paul D; Matta, Fadi; Lawrence, Frank R; Hughes, Mary J
2018-04-01
Administrative data have shown a lower mortality in hospitalized patients with pulmonary embolism and cancer who receive a vena cava filter. In the absence of a randomized controlled trial of vena cava filters in such patients, further investigation is necessary. Therefore, we performed this investigation using administrative data from a different database than used previously, and we investigate patients hospitalized in more recent years. We analyzed administrative data from the Premier Healthcare Database, 2010-2014, in patients hospitalized with pulmonary embolism and solid malignant tumors. Patients were identified on the basis of International Classification of Disease, Ninth Revision, Clinical Modification codes. Patients aged >60 years had a lower in-hospital all-cause mortality with vena cava filters than those who did not have filters, 346 of 4648 (7.4%) compared with 2216 of 19,847 (11.2%) (P < .0001) (relative risk 0.67). Among patients aged >60 years who received an inferior vena cava, all-cause mortality within 3 months was 704 of 4648 (15.1%), compared with 3444 of 19,847 (17.4%) among those who did not receive a filter (P < .0001) (relative risk 0.86). Elderly patients with pulmonary embolism and cancer may be a special population in whom inferior vena cava filters reduce in-hospital and 3-month all-cause mortality. Further investigation is needed, particularly in younger patients. Copyright © 2018. Published by Elsevier Inc.
Vena Cava 3D Contrast-Enhanced MR Venography: A Pictorial Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin Jiang; Zhou Kangrong; Chen Zuwang
Three-dimensional contrast-enhanced magnetic resonance venography (CE MRV) is a sensitive and accurate method for diagnosing vena cava pathologies. The commonly used indirect approach involves a nondiluted gadolinium contrast agent injected into an upper limb vein or, occasionally, a pedal vein for assessment of the superior or inferior vena cava. In our studies, a coronal 3D fast multi-planar spoiled gradient-echo acquisition was used. A pre-contrast scan was obtained to ensure correct coverage of the region of interest. We initiated contrast-enhanced acquisition 15 sec after the start of contrast agent injection and performed the procedure twice. The image sets were obtained duringmore » two 20-30-sec breath hold, with a breathing rest of 5-6 sec, to obtain the first-pass and delayed arteriovenous phases. For patients with Budd-Chiari syndrome, a third acquisition coinciding with late venous phase was collected to visualize the hepatic veins, which was carried out by one additional acquisition after a 5-6-sec breathing time. This review describes the clinical application of 3D CE MRV in vena cava congenital anomalies, superior and inferior vena cava syndrome, Budd-Chiari syndrome, peripheral vein thrombosis extending to the vena cava, pre-operational evaluation in portosystemic shunting and post-surgical follow-up, and road-mapping for the placement and evaluation of complications of central venous devices.« less
Madjarov, Jeko M; Katz, Michael G; Madjarova, Sophia; Madzharov, Svetozar; Arko, Frank R; Miller, David W; Robicsek, Francis
2018-05-21
An anomalous muscle bundle crossing the right atrial cavity represents a pathological finding with unproved clinical significance. This congenital anomaly may be difficult to recognize via echocardiography and could be confused with other intra-cavitary lesions. We report a case of a 53-year-old female presented to the cardio-vascular service with acute superior vena cava syndrome and sub-massive pulmonary embolism. The patient underwent venography confirming superior vena cava stenosis. A ventilation/perfusion lung scan showed two sizable perfusion defects due to pulmonary embolism. MRI and echocardiography imaging demonstrated right atrium mass. Surgery was then carried out using standard cardiopulmonary bypass; right atrial muscle bundle was excised and superior vena cava reconstruction was performed. The patient was discharged uneventfully and remains symptom-free at two years follow-up. In cases of nonmalignant pathology of superior vena cava syndrome, appropriate studies should be conducted to exclude potential congenital abnormalities such as this anomalous muscle bundle in the right atrium. Open heart surgery is a viable treatment option in select cases. Published by Elsevier Inc.
Nath, Ranjit Kumar; Soni, Dheeraj Kumar
2015-12-01
A 22-year-old woman with severe mitral stenosis was referred to us for further evaluation and management. She was found to have severe mitral stenosis, severe tricuspid regurgitation with dilated right atrium and right ventricle with persistent left superior vena cava and hugely dilated coronary sinus. Valve was suitable for balloon mitral valvotomy. Cardiac catheterization showed interrupted inferior vena cava with azygos continuation to right atrium and large left superior vena cava draining to coronary sinus which was very much dilated. Right trans-jugular approach was tried for balloon mitral valvotomy, but was unsuccessful due to a very large right atrium and coronary sinus. Retrograde non trans-septal approach was used and balloon valvotomy was done successfully using a 24 mm × 40 mm TYSHAK balloon without any major complication. Reduction in the transmitral pressure gradient on cardiac catheterization data and transthoracic echocardiography confirmed successful procedure. Balloon mitral valvotomy can be done successfully in patients with the above unusual cardiac anatomy with no major procedural complications. © 2015 Wiley Periodicals, Inc.
Sabzi, Feridoun
2016-01-01
Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261
Tansel, T; Harmandar, B; Dayioglu, E; Onursal, E
2006-02-01
The majority of patients with partial anomalous drainage of pulmonary veins are asymptomatic during infancy and childhood. Patients with significant left-to-right shunt develop symptoms and benefit from early corrective surgery. Anomalous pulmonary veins draining into inferior vena cava is very rare and frequently encountered in association with scimitar syndrome. The purpose of this case report is to describe a non-scimitar patient with cor triatriatum who had anomalous dual drainage of right pulmonary veins into inferior vena cava/left atrium and anomalous connection of persistent left superior vena cava with a common pulmonary venous chamber. The patient underwent an operation with redirection of anomalous pulmonary venous drainage into left atrium and ligation of persistent left superior vena cava.
Mediastinal fibrosis and superior vena cava syndrome.
Novella Sánchez, Laura; Sanz Herrero, Francisco; Berraondo Fraile, Javier; Fernández Fabrellas, Estrella
2013-08-01
Superior vena cava syndrome is a clear sign for clinicians of infiltrative mediastinal involvement, usually caused by neoplasms in this location, and it is an indicator of poor prognosis. However, other diseases of benign origin can also cause these alterations. We present the case of a 34-year-old patient who debuted with symptoms of superior vena cava syndrome due to idiopathic mediastinal fibrosis, which presented a torpid evolution and few therapeutic alternatives. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.
[Superior vena cava syndrome--clinical aspects, etiology and case reports].
Serdarevic, M; Löhr, E; Reidemeister, J C
1984-06-01
The so-called superior-Cava Syndrome is caused by obstructions by centrally localized tumors by thrombosis or by inflammations of the mediastinum. In cases of tumorous infiltration a graft can be inserted. The different phenomena of thrombosis caused by nutritial catheters and pace makers are of clinical importance. Acute thrombosis of the brachio-cervical veins and the Vena Cava can be treated successfully by means of thrombolysis. Besides CT bilateral brachial phlebography communicates optimal information concerning localization of vascular obstruction and collateral circuits.
Kovac, Jason R; Luke, Patrick P
2010-01-01
Excision of renal cell carcinoma (RCC) with corresponding vena cava thrombus is a technical challenge requiring open resection and vascular clamping. A 58 year old male with a right kidney tumor presented with a thrombus extending 1 cm into the vena cava. Using a hand-assisted transperitoneal approach through a 7 cm gel-port, the right kidney was dissected and the multiple vascular collaterals supplying the tumor were identified and isolated. The inferior vena cava was mobilized 4 cm cephalad and 4 cm caudal to the right renal vein. Lateral manual traction was applied to the right kidney allowing the tumor thrombus to be retracted into the renal vein, clear of the vena cava. After laparoscopic ultrasonographic confirmation of the location of the tip of the tumor thrombus, an articulating laparoscopic vascular stapler was used to staple the vena cava at the ostium of the right renal vein. This allowed removal of the tumor thrombus without the need for a Satinsky clamp. The surgery was completed in 243 minutes with no intra-operative complications. The entire kidney and tumor thrombus was removed with negative surgical margins. Estimated blood loss was 300 cc. We present a laparoscopic resection of a renal mass with associated level II thrombus using a hand-assisted approach. In patients with minimal caval involvement, our surgical approach presents an option to the traditional open resection of a renal mass.
Köcher, Martin; Krcova, Vera; Cerna, Marie; Prochazka, Martin
2009-04-01
To evaluate the feasibility and efficacy of the retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep vein thrombosis in the perinatal period and to discuss the technical demands associated with the filter's implantation and retrieval. Between 1996 until 2007, eight women (mean age 27.4 years, range 20-42 years) with acute deep iliofemoral venous thrombosis in the perinatal period of pregnancy and increased risk of pulmonary embolism during delivery were indicated for retrievable Günther Tulip Vena Cava Filter implantation. All filters were inserted and removed under local anesthesia from the jugular approach. The Günther Tulip Vena Cava Filter was implanted suprarenally in all patients on the day of caesarean delivery. In follow-up cavograms performed just before planned filter removal, no embolus was seen in the filter in any patient. In all patients the filter was retrieved without complications on the 12th day after implantation. Retrievable Günther Tulip Vena Cava Filters can be inserted and removed in patients during the perinatal period without major complications.
GdnHCl-induced unfolding intermediate in the mitochondrial carbonic anhydrase VA.
Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Hassan, Md Imtaiyaz; Ahmad, Faizan
2016-10-01
Carbonic anhydrase VA (CAVA) is a mitochondrial enzyme belonging to the α-family of CAs, which is involved in several physiological processes including ureagenesis, lipogenesis, gluconeogenesis and neuronal transmission. Here, we have tried to understand the folding mechanism of CAVA using guanidine hydrochloride (GdnHCl)-induced denaturation at pH 8.0 and 25°C. The conformational stability was measured from the GdnHCl-induced denaturation study of CAVA monitored by circular dichroism (CD) and fluorescence measurements. On increasing the concentration of GdnHCl up to 5.0, a stable intermediate was observed between the concentrations 3.25M to 3.40M of the denaturant. However, CAVA gets completely denatured at 4.0M GdnHCl. The existence of a stable intermediate state was validated by 1-anilinonaphthalene-8-sulfonic acid (ANS binding) fluorescence and near-UV CD measurements. In silico studies were also performed to analyse the effect of GdnHCl on the structure and stability of CAVA under explicit conditions. Molecular dynamics simulations for 40ns were carried out and a well-defined correlation was established for both in vitro and in silico studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines.
Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel
2016-10-27
Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na⁺, K⁺, Ca 2+ , Cl - , and CO₃ 2- , one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.
Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines
Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel
2016-01-01
Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions. PMID:27801796
DOE Office of Scientific and Technical Information (OSTI.GOV)
McConville, R. M., E-mail: richard_mcconville@hotmail.com; Kennedy, P. T.; Collins, A. J.
Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standardmore » anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.« less
Noji, S; Kitamura, N; Yamaguchi, A; Otaki, M; Miki, T; Tamura, H
1991-08-01
We present a surgical case of 41-year-old woman with Scimitar syndrome. Preoperative catheterization showed azygos connection and L-R shunt ratio of 45% without intracardiac malformations. To our knowledge, this combination has not been previously reported. At operation the right single pulmonary vein was found and drained into the inferior vena cava below the diaphragm. Because of counter clockwise rotation of the heart the distance of the scimitar vein and the left atrium was too long for direct anastomosis, a polytetrafluoroethylene tube (10 mm in diameter) was utilized for an extracardiac conduit using cardiopulmonary bypass. Postoperative course was uneventful. We conclude that this technique is effective for this syndrome with a large amount of L-R shunt and a sufficient patency is expected.
Helfand, Brian T; Smith, Norm D; Kozlowski, James M; Eskandari, Mark K
2011-01-01
Inferior vena cava (IVC) reconstruction for locally advanced renal cell carcinoma (RCC) includes resection with and without interposition grafting, patch graft, or primary repair. The proposed benefits of lateral venorrhaphy and primary repair are avoidance of foreign material, a more expeditious repair, and preservation of lower extremity venous outflow. A single-center retrospective review of 22 patients with RCC and IVC tumor thrombus treated with radical nephrectomy, lateral venorrhaphy, thrombectomy, and primary vena cava repair between July 2002 and June 2009 was carried out. Demographic data, diagnostic information, radiographic cross-sectional imaging, and procedural outcomes were examined. Among the 13 men and nine women, the mean age was 62.1 years (42-83); mean tumor size was 9.8 cm (3-17 cm), and 90% (n = 18) of the cases with RCC were identified pathologically as clear cell adenocarcinoma; on the basis of the classification system adopted by Neves, level I was for 50% (n = 11), level II for 32% (n = 7), level III for 9% (n = 2), and level IV for 9% (n = 2) of the patients. All patients underwent en bloc radical nephrectomy with tumor thrombus removal and primary IVC repair. Mean total operative time was 547.9 ± 138.5 minutes, whereas mean IVC cross-clamp time was 10.8 minutes (6-29 minutes). There were no intraoperative deaths or pulmonary embolism and all IVC margins were found to be pathologically negative. Postoperative complications included one pulmonary embolism, one exacerbation of chronic lymphedema, and two cases of new onset erectile dysfunction. Mean follow-up was 36.4 ± 23.2 months (6-92 months). There were no radiographic or clinically significant changes in mean IVC diameter during follow-up. Five late deaths (23%) occurred as a result of metastatic RCC over a mean period of 24 months (range, 12-48), but without any local recurrences. For advanced RCC with tumor thrombus extension into the IVC, lateral venorrhaphy and primary IVC repair avoids complicated caval reconstructions and results in high patency rates with a low local tumor recurrence rate. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Heart block and cardiac embolization of fractured inferior vena cava filter.
Abudayyeh, Islam; Takruri, Yessar; Weiner, Justin B
2016-01-01
A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures. The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process. This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation. Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.
Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna
2014-01-01
Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.
[Syndrome of vena cava obstruction in oncology].
Kohútek, F; Litvin, I; Tamášová, M; Bystrický, B
2013-01-01
Superior vena cava syndrome (SVCO) is caused by compression of superior vena cava and restriction of blood flow to the heart. The most common underlying condition in cancer patients is lung cancer or other malignancy expanding in the upper mediastinum. SVCO belongs to oncological emergencies and requires a prompt dia-gnostic work up and treatment. A 79year old man with a history of right sided stage IIIB nonsmall cell lung cancer, after two cycles of chemotherapy, was admitted to hospital with clinical signs of SVCO. The initial radiotherapy brought no relief of symptoms and due to deterioration of patients status during the treatment we proceeded to self expanding caval stent insertion. This was followed by immediate resolution of SVCO symptoms. In the second case we describe a 56year old female with a newly dia-gnosed diffuse large B cell lymphoma who presented with SVCO symptoms when referred to our outpatient chemotherapy department. She had no history of previous treatment and she complained of a rapid face and eyelid edema and intractable cough in the last two days. CT scan revealed mediastinal mass compressing the superior vena cava. Urgent antilymphoma chemotherapy (RCHOP schedule) was commenced and yielded quick resolution of her symp-toms. Superior vena cava syndrome is a medical emergency in oncological patients usually caused by external compression of cava by lung cancer, lymphoma, other tumors, less frequently, from a thrombosis of indwelling central venous catheter. Multidiscip-linary cooperation among radiation and medical oncologists and interventional radiologists is needed in order to provide an early treatment without an undue delay.
Human aortic allograft: an excellent conduit choice for superior vena cava reconstruction
2014-01-01
Superior vena cava (SVC) reconstruction is occasionally required in the treatment of benign and malignant conditions. We report a patient with symptomatic SVC obstruction secondary to mediastinal fibrosis successfully reconstructed with an aortic allograft. PMID:24428914
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fretz, V.; Binkert, C. A., E-mail: Christoph.Binkert@ksw.c
May-Thurner syndrome is known as compression of the left common iliac vein by the right common iliac artery. We describe a case of an atypical compression of the inferior vena cava by the right common iliac artery secondary to a high aortic bifurcation. Despite an extensive collateral network, there was a significant venous gradient between the iliac veins and the inferior vena cava above the compression. After stenting the venous pressure gradient disappeared. Follow-up 4 months later revealed a good clinical response with a patent stent.
Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.
Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca
2006-09-01
Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.
Lee, Ji-Hyeok; Ko, Ju-Young; Oh, Jae-Young; Kim, Chul-Young; Lee, Hee-Ju; Kim, Jaeil; Jeon, You-Jin
2014-09-01
Various bioactive phlorotannins of Ecklonia cava (e.g., dieckol, eckol, 6,6-bieckol, phloroglucinol, phloroeckol, and phlorofucofuroeckol-A) are reported. However, their isolation and purification are not easy. Centrifugal partition chromatography (CPC) can be used to efficiently purify the various bioactive-compounds efficiently from E. cava. Phlorotannins are successfully isolated from the ethyl acetate (EtOAc) fraction of E. cava by CPC with a two-phase solvent system comprising n-hexane:EtOAc:methanol:water (2:7:3:7, v/v) solution. The dieckol (fraction I, 40.2mg), phlorofucofuroeckol-A (fraction III, 31.1mg), and fraction II (34.1mg) with 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are isolated from the crude extract (500 mg) by a one-step CPC system. The purities of the isolated dieckol and phlorofucofuroeckol-A are ⩾90% according to high performance liquid chromatography (HPLC) and electrospray ionization multi stage tandem mass spectrometry analyses. The purified 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are collected from fraction II by recycle-HPLC. Thus, the CPC system is useful for easy and simple isolation of phlorotannins from E. cava. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chessa, Massimo; Carminati, Mario; Cinteză, Eliza Elena; Butera, Gianfranco; Giugno, Luca; Arcidiacono, Carmelo; Piazza, Luciane; Bulescu, Nicolae Cristian; Pome, Giuseppe; Frigiola, Alessandro; Giamberti, Alessandro
2016-01-01
Abnormal connection of the right superior caval vein to the left atrium is an uncommon systemic vein drainage anomaly, with only a few cases reported among congenital heart disease (CHD), around 20 cases published in the medical literature. The inferior vena cava connection with the left atrium, also very rare, can appear directly or in heterotaxy. Clinical suspicion arises due to the presence of cyanosis in the absence of other specific clinical signs (without other associated CHD). We present the cases of two children with abnormal superior and inferior systemic venous return. The first case is an abnormal connection of right superior vena cava to the left atrium associated with persistent left superior vena cava draining into the right atrium through the coronary sinus. The second case is an interruption of the inferior vena cava with hemiazygos continuation, drained into the left superior vena cava, which drained into the left atrium. The diagnosis was imagistic - echocardiography and angiography. Surgical treatment solutions vary from one case to another, usually following anatomic correction. Hypoxia accompanied by cyanosis must bring into question the pathology of systemic venous drainage anomaly, after other common causes have been excluded. Surgery is indicated in all cases due to the risk associated with the presence of right-to-left shunt.
Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz
2016-09-01
Carbonic anhydrase VA (CAVA) is primarily expressed in the mitochondria and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis and neuronal transmission. To understand the biophysical properties of CAVA, we carried out a reversible urea-induced isothermal denaturation at pH 7.0 and 25°C. Spectroscopic probes, [θ]222 (mean residue ellipticity at 222 nm), F344 (Trp-fluorescence emission intensity at 344 nm) and Δε280 (difference absorption at 280 nm) were used to monitor the effect of urea on the structure and stability of CAVA. The urea-induced reversible denaturation curves were used to estimate [Formula: see text], Gibbs free energy in the absence of urea; Cm, the mid-point of the denaturation curve, i.e. molar urea concentration ([urea]) at which ΔGD = 0; and m, the slope (=∂ΔGD/∂[urea]). Coincidence of normalized transition curves of all optical properties suggests that unfolding/refolding of CAVA is a two-state process. We further performed 40 ns molecular dynamics simulation of CAVA to see the dynamics at different urea concentrations. An excellent agreement was observed between in silico and in vitro studies.
Allen, Todd L; Carter, Jody L; Morris, Brad J; Harker, Colleen P; Stevens, Mark H
2005-06-01
Venous thromboembolic (VTE) disease remains a significant cause of morbidity for trauma patients because many patients have injuries that may preclude effective VTE prevention and treatment. Retrievable vena cava filters may prove beneficial in this subset of trauma patients. Trauma patients at risk for VTE were identified and managed by institutional protocol. Patients who required a vena cava filter were managed with a device that could be retrieved or left in situ. A retrospective review of medical records was used to identify the use, indications, and complications associated with a retrievable filter. Fifty-three retrievable filters were placed in 51 patients. Two of these patients received a second filter, and 1 received a filter in the superior vena cava. Thirty-two filters were placed prophylactically, whereas 21 were placed for demonstrated venous thromboembolism (VTE). Retrieval was successful in 24 of 25 attempts. Twenty-nine filters became permanent: 10 for continued contraindications to anticoagulation without known VTE, 12 for known VTE and continued contraindications to anticoagulation, 1 for technical reasons, and 6 because of patient death. There were no complications of bleeding, device migration or thrombosis, infection, or pulmonary embolism. A retrievable vena cava filter appears safe and effective for the prevention of pulmonary embolism in the high-risk trauma patient who cannot receive anticoagulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu; Wagner, Daniel, E-mail: Daniel.Wagner@osumc.edu; Elliott, Eric, E-mail: Eric.Elliott@osumc.edu
PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15more » females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.« less
Komatsu, Shohei; Kido, Masahiro; Asari, Sadaki; Toyama, Hirochika; Ajiki, Tetsuo; Demizu, Yusuke; Terashima, Kazuki; Okimoto, Tomoaki; Sasaki, Ryohei; Fukumoto, Takumi
2017-12-01
Hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus carries a dismal prognosis, and the feasibility of local treatment has remained controversial. The present study aimed to compare the outcomes of particle radiotherapy and liver resection in patients with hepatocellular carcinoma with inferior vena cava tumor thrombus. Thirty-one and 19 patients, respectively, underwent particle radiotherapy and liver resection for hepatocellular carcinoma with inferior vena cava tumor thrombus. A matched-pair analysis was undertaken to compare the short- and long-term outcomes according to tumor stage determined using the tumor-node-metastasis classification. Both stages IIIB and IV (IVA and IVB) patients were well-matched for 12 factors, including treatment policy and patient and tumor characteristics. The median survival time of matched patients with stage IIIB tumors in the particle radiotherapy group was greater than that in the liver resection group (748 vs 272 days, P = .029), whereas no significant difference was observed in the median survival times of patients with stage IV tumors (239 vs 311 days, respectively). There were significantly fewer treatment-related complications of grade 3 or greater in the particle radiotherapy group (0%) than in the liver resection group (26%). Particle radiotherapy is potentially preferable in hepatocellular carcinoma patients with stage IIIB inferior vena cava tumor thrombus and at least equal in efficiency to liver resection in those with stage IV disease, while causing significantly fewer complications. Considering the relatively high survival and low invasiveness of particle radiotherapy when compared to liver resection, this approach may represent a novel treatment modality for hepatocellular carcinoma with inferior vena cava tumor thrombus. Copyright © 2017 Elsevier Inc. All rights reserved.
OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onat, Levent, E-mail: levonat2@yahoo.com; Ganiyusufoglu, Ali Kursat; Mutlu, Ayhan
We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9).more » Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.« less
Ikai, Akio; Shirai, Mikiyasu; Nishimura, Kazunobu; Ikeda, Tadashi; Kameyama, Takayuki; Ueyama, Koji; Komeda, Masashi
2005-01-01
After cavopulmonary shunt in which the superior vena cava is anastomosed to the right pulmonary artery, the right lung is in a unique condition without flow pulsatility and hepatic venous effluent. In a previous study, we reported that hypoxic pulmonary vasoconstriction disappeared in the pulmonary circulation after cavopulmonary shunt. In this study, however, to investigate the influence of pulsatility and hepatic venous effluent on hypoxic pulmonary vasoconstriction in the pulmonary circulation, we developed an alternative cavopulmonary shunt rabbit model that included hepatic venous effluent in the pulmonary circulation and reduced the pulsatility of the pulmonary arterial blood flow. We then observed the physiologic characteristics of the peripheral pulmonary artery after cavopulmonary shunt, specifically the disappearance of hypoxic pulmonary vasoconstriction. Sixteen Japanese white rabbits (12-16 weeks old) were used in this study. With general anesthesia, a cavopulmonary shunt was established by anastomosing the right superior vena cava to the right pulmonary artery in an end-to-side fashion. Of the 16 rabbits for the study, the proximal right pulmonary artery was completely ligated in 5 (atresia group) and partially ligated in 6 (stenosis group). Sham operation was performed in the remaining 5 rabbits. Two weeks later, we analyzed the response of the pulmonary artery (which was divided into three categories: segmental, lobular, and acinar level artery) to hypoxia (8% oxygen inhalation) with a specially designed video radiographic system. Morphometric analysis of the resistance pulmonary artery was done in each group after angiography. Mean pressure and pulse pressure in the right pulmonary artery were not significantly different between the atresia and stenosis groups. The mean pulmonary artery pressures in the atresia and stenosis groups were 8 and 11 mm Hg, respectively. However, the pulse pressure was less than 2 mm Hg in both groups. The baseline internal diameter of the resistance pulmonary artery of the atresia group was significantly different from those of the stenosis and sham groups. In the atresia group, the resistance pulmonary arteries did not respond to hypoxia. In contrast, significant constriction (as assessed by percentage change of internal diameter of the resistance pulmonary arteries in the acinar and lobular level arteries) was observed in the pulmonary arteries of the sham and stenosis groups (atresia vs stenosis vs sham 0.4% vs - 19.0% vs - 18.8%, P = .01). In our morphometric study, we observed vasodilation of the resistance pulmonary artery with a thinner medial layer in the atresia group, consistent with the result of microangiography. We developed a cavopulmonary shunt rabbit model in which the inferior vena caval blood was derived from the right ventricle. Hypoxic pulmonary vasoconstriction was maintained in the model with the blood flow from the right ventricle. When the blood flow was not maintained, however, hypoxic pulmonary vasoconstriction disappeared. This phenomenon strongly suggests that a substance in hepatic venous effluent partially regulates the physiological pulmonary vascular function in the rabbit lung.
Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru
2015-09-01
Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.
Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm
2018-01-01
A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.
Mizuno, A; Nakamura, Y; Takayasu, H; Saitoh, H
1993-05-01
Successful repair of a 8-month-old girl with polysplenia was reported. The cardiovascular anomalies were TAPVC (II b), incomplete ECD, interruption of inferior vena cava with hemiazygos continuation, bilateral superior vena cava, and left superior vena cava draining into the coronary sinus. Cardiopulmonary bypass was established with ascending aortic perfusion and caval cannulation. A left superior vena cava was directly cannulated after establishing partial bypass. In this case the left pulmonary vein drained into the right atrium near the orifice of the coronary sinus, so the atrial septal flap was made and sutured between the orifice of the left pulmonary vein and the coronary sinus in order to avoid late pulmonary vein obstruction. Then, atrium was separated by an intraatrial baffle which was sutured to the atrial septal flap. Recently, it becomes possible to surgical repair of polysplenia syndrome according to the advancements of the diagnostic methods, cardiopulmonary bypass, and the technique of the open heart surgery.
Truman, A T; Rao, P S; Kulangara, R J
1980-01-01
A 4-month-old infant with cyanosis but without other abnormal cardiac findings is presented in whom the diagnosis of anomalous systemic venous connection to the left atrium was made by contrast echocardiography. The diagnosis was later confirmed by cardiac catheterisation and selective cineangiography. When saline was injected into a vein on the dorsum of each hand while echocardiographically recording the cardiac structures, the left atrium, left ventricle, and aorta were opacified without visualisation of the right ventricle. Similar study with injection into the right foot produced opacification of the right ventricle without visualisation of the left-sided structures. These data suggested normal drainage of the inferior vena cava with anomalous connection of the superior vena cava to the left atrium. A review of the previously reported cases of anomalous connection of the right superior vena cava to the left atrium is presented together with the possible embryological origin of this anomaly. Images PMID:7459157
Construction of Continental Crust at the Central American and Philippines Arc Systems
NASA Astrophysics Data System (ADS)
Whattam, S. A.; Stern, R. J.
2016-12-01
Whether or not magmatic arcs evolve compositionally with time and the processes responsible remain controversial. Resolution of this question requires reconstructing arc geochemical evolution at the level of discrete arc systems, as has been done for IBM, Central America, and the Greater Antilles. Emphasis should be on arcs built on oceanic crust because interaction with continental crust complicates interpretations. The Philippines are a particularly attractive target because this may be the best example where proto-continental crust has been generated and processed in Cretaceous and younger time. Here, we show how this question could be addressed for the Philippines using the well-studied Central American Volcanic Arc System (CAVAS) as an example. For the CAVAS, we avoided the northern arc segment because these are (Guatemala) or maybe (El Salvador) sections built on continental crust. Geochemical and isotopic data were compiled for 1031 samples of lavas and intrusive rocks from the 1100 km-long segment built on thickened, initially plume-derived oceanic crust over its 75 million year lifespan (Panama, Costa Rica, Nicaragua) . The most striking observation is the overall evolution of the CAVAS to more incompatible element enriched and ultimately continental-like compositions with time. Models entailing progressive arc magmatic enrichment are generally supported by the CAVAS record. Progressive enrichment of the oceanic CAVAS with time reflects changes in mantle wedge composition and decreased melting due to arc crust thickening, which was kick-started by the involvement of enriched plume mantle. Progressive crustal thickening and associated changes in the sub-arc thermal regime resulted in decreasing degrees of partial melting over time, which allowed for progressive enrichment of the CAVAS and ultimately the production of continental-like crust in Panama and Costa Rica by 16-10 Ma. Our similar study of the Philippine Arc system is in its infancy but earlier studies have shown that older magmatic rocks are tholeiitic and MORB-like whereas younger ones are invariably calc-alkaline and arc-like. Results of the Philippines Arc study will be compared with the CAVAS and other magmatic arc systems comprised of continental crust.
Nicolas, M; Malvé, M; Peña, E; Martínez, M A; Leask, R
2015-02-05
In this study, the trapping ability of the Günther Tulip and Celect inferior vena cava filters was evaluated. Thrombus capture rates of the filters were tested in vitro in horizontal position with thrombus diameters of 3 and 6mm and tube diameter of 19mm. The filters were tested in centered and tilted positions. Sets of 30 clots were injected into the model and the same process was repeated 20 times for each different condition simulated. Pressure drop experienced along the system was also measured and the percentage of clots captured was recorded. The Günther Tulip filter showed superiority in all cases, trapping almost 100% of 6mm clots both in an eccentric and tilted position and trapping 81.7% of the 3mm clots in a centered position and 69.3% in a maximum tilted position. The efficiency of all filters tested decreased as the size of the embolus decreased and as the filter was tilted. The injection of 6 clots raised the pressure drop to 4.1mmHg, which is a reasonable value that does not cause the obstruction of blood flow through the system. Copyright © 2014 Elsevier Ltd. All rights reserved.
Intraatrial baffle repair of isolated ventricular inversion with left atrial isomerism.
McElhinney, D B; Reddy, V M; Silverman, N H; Hanley, F L
1996-11-01
Isolated ventricular inversion with left atrial isomerism, partial anomalous pulmonary venous connection, and interruption of the inferior vena cava with azygos continuation to a right superior vena cava was diagnosed by echocardiography in a neonate. At 48 days of age, the patient underwent successful anatomic correction with redirection of flow from the superior vena cava and hepatic veins to the left-sided tricuspid valve, and flow from the pulmonary veins to the right-sided mitral valve. In the present report, the surgical techniques of this case are described, along with a survey of the surgical literature covering anatomic repair of isolated ventricular inversion.
Nutcracker syndrome and deep venous thrombosis in a patient with duplicated inferior vena cava.
Yoshida, Ricardo de Alvarenga; Yoshida, Winston Bonetti; Costa, Renato Fanchiotti; Nacif, Marcelo Souto; Sobreira, Marcone Lima; Jaldin, Rodrigo Gibin
2016-04-01
Duplicated inferior vena cava is a rare anomaly, and thrombosis in one or both segments is even less frequent. We present a case of deep venous thrombosis of the left lower limb involving the popliteal, femoral, and iliac veins as well as the left segment of the duplicated vena cava and nutcracker syndrome. After catheter-directed thrombolysis complemented by mechanical thrombolysis, the compromised veins had complete revascularization; the nutcracker syndrome was treated with stent placement, followed by the use of anticoagulants. There was technical success and complete recovery of the patient. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Janssen, S; van Donselaar-van der Pant, K A M I; van der Weerd, N C; Develter, W; Bemelman, F J; Grobusch, M P; Idu, M M; Ten Berge, I J M
2013-02-01
Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous collateral veins of the abdominal wall contra-laterally to the renal transplant. Cultures from abdominal wall micro-abscesses yielded Prevotella bivia as the causative agent. This complication has not been described before in the context of renal transplantation. The pathogenesis and management of this serious complication are discussed in this paper.
Higutchi, C; Sarraf, Y S; Nardino, É P; Pereira, W M G; Daboin, B E G; Carvalho, L E W; Correa, J A
2017-01-01
This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins) who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC) and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis.
Ait-Oufella, Hafid; Boelle, Pierre-Yves; Galbois, Arnaud; Baudel, Jean-Luc; Margetis, Dimitri; Alves, Mikael; Offenstadt, Georges; Maury, Eric; Guidet, Bertrand
2012-06-28
Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.
Rüter, Jens; Hoffmann, Torsten; Demuth, Hans-Ulrich; Moschansky, Petra; Klapp, Burghard F; Hildebrandt, Martin
2004-06-01
We assessed changes of the enzyme dipeptidyl peptidase IV (DPP IV, CD26) in the context of leptin or leptin receptor deficiency. C57BL/6 mice, Leptin-deficient mice (ob/ob mice, B6.V-Lep
[How efficient and safe are Vena-cava-filters?].
Kluge, Stefan
2015-08-01
In the last 30 years patients with pulmonary embolism have increasingly often been implanted with a vena cava filter. Evidence of safety and efficacy in comparison to pure anticoagulation are in short supply. Re-removable filter reduces neither the risk of recurrence nor mortality, according to a study now revealed.
Vohra, H A; Phillips, N J; Nel, L; Diprose, P; Ohri, S K
2010-06-01
We report a unilateral right atrial familial myxoma with a multicentric nature discovered during cardiac surgery. After the patient was weaned off cardiopulmonary bypass, an inferior vena cava myxoma was discovered with intra-operative trans-oesophageal echocardiogram (TOE) which had been missed preoperatively and during surgery.
Biofouling attractants from a brown marine alga Ecklonia cava.
Sidharthan, M; Viswanadh, G S; Kim, Kyoung Ho; Kim, Hyuk Jun; Shin, H W
2007-04-01
In recent years, industrial pollutants and the mountain forest fire ashes released into seawater cause damage to the marine environment, mainly it reduces the algal productivity in the inter tidal region. To get recover from the stress due to pollutants and to increase the growth and development of biofouling algae (benthic organisms), Ecklonia cava extract was investigated for its biofouling attracting efficiency. Bioactive guided fractions of E. cava extract derived from column chromatography were tested against spore attachment of a fouling alga, Ulva pertusa. Fraction B showed increased spore attachment rate with a maximum of 92 +/- 5%. This fraction was further analysed on HPLC, GC-Mass and NMR, deduced as pentadecanoic acid.
Percutaneous retrieval of a right atrioventricular embolus.
Davies, R P; Harding, J; Hassam, R
1998-01-01
Percutaneous retrieval of a 12-cm-long serpiginous clot lodged in the right atrium and ventricle is reported. Following bilateral common femoral vein puncture, a Bird's Nest cava filter was first positioned ready to deploy immediately below the renal veins via the right femoral vein. From the left femoral vein, a Cook intravascular retrieval basket was advanced to the right atrium. Under transthoracic echocardiographic visualization, the basket was used to engage, trap, and gently withdraw the clot in a single long strand below the prepositioned inferior vena cava filter. The filter was immediately deployed, leaving the clot trapped inferior to the renal veins, in the cava and left iliac vein. The patient remained well and asymptomatic at discharge.
Parsaee, Mozhgan; Pouraliakbar, Hamidreza; Ghadrdoost, Behshid; Moosavi, Jamal; Behjati, Mohaddeseh
2018-06-10
The most commonly reported collateral systems in the setting of superior vena cava obstruction are azygos venous system, vertebral venous system, external and internal thoracic venous system based on McLntire and Sykes classification. A 49-year-old female with renal disease complained dyspnea on exertion. Transesophageal echocardiography showed significant mitral annular calcification, large multi-lobulated mass at posterior aspect of RA, and complete obstruction of superior vena cava by thrombus formation. Computed tomography angiography showed a collateral vein to the left atrium (LA) roof. This case report is the first one which shows development of collateral vein from right subclavian to LA. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br; Santos, Aline Cristine Barbosa; Tannuri, Uenis
We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge ofmore » the stent.« less
Günal, N; Bilgiç, A; Lenk, M K; Yurdakul, Y; Sarigül, A; Ispir, S
1996-03-01
A 4-year-old boy with abnormal connection of the inferior vena cava to the left atrium and double outlet right ventricle and right atrial isomerism is presented. The anomalies were detected by echocardiography and angiography, and later verified through surgical intervention.
Scimitar sign with normal pulmonary venous drainage and anomalous inferior vena cava.
Herer, B; Jaubert, F; Delaisements, C; Huchon, G; Chretien, J
1988-01-01
A case of the scimitar sign due to an anomaly of the right sided pulmonary vein with normal drainage into the left atrium was associated with an azygos continuation of the inferior vena cava. Digital subtraction angiography allows the identification of these rare congenital vascular malformations. Images PMID:3175980
Inferior Vena Cava Filters: Current and Future Concepts.
Kaufman, John Andrew
2018-01-01
The inferior vena cava filter clinical environment is notable for the degree of controversy, uncertainty, and fear associated with these devices by both physicians and the public. This article reviews some of the more important current issues with these devices as well as emerging and future trends. Copyright © 2017 Elsevier Inc. All rights reserved.
Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei
2004-08-01
A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.
Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing
2013-06-04
To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.
Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun
2017-01-01
Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908
Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel
2018-02-23
Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.
Appropriate donor size for porcine liver xenotransplant.
Soleimani, Mehrdad; Fonouni, Hamidreza; Esmaeilzadeh, Majid; Kashfi, Arash; Fani Yazdi, Seyed Hashem; Golriz, Mohammad; Hafezi, Mohammadreza; Rahbari, Nuh N; Schmidt, Jan; Mehrabi, Arianeb
2012-04-01
Owing to an imbalance between demand and supply, which is more prominent in pediatric transplant, every year more patients lose their lives on waiting lists. In addition to the use of deceased-donor split and living-donor organs, xenotransplant could provide a solution if associated problems, such as immunologic and physiologic ones, are solved. This study sought to analyze the surgical aspects for liver xenotransplant in a porcine model. Landrace pigs (n=22, 23 to 37 kg) underwent a laparotomy under general anesthesia. The hepatic hilum was prepared and the common bile ducts, common hepatic artery, portal vein, supra- and infrahepatic inferior vena cava were identified. The length and diameter of each vessel and bile duct and the weight of the liver were measured. Pearson tests showed a clear correlation between the increase of the pigs' weight and the livers' weight, and the length of the vessels and the bile ducts. We did not find a clear correlation between the increase of the pigs' liver weight and the diameters of the vessels and the bile duct. As the first reporting, this study on xenotransplants from the surgical point of view, we postulate that it could be possible to estimate the size of the liver and the proper length of its vessels and bile duct by weighing only the pigs. It was not feasible to match the diameter of mentioned structures by the livers' weight. However, the weight of pig's liver as well as vascular anatomy of pigs appeared to be suitable alternative for the human liver.
Anatomy of the patent foramen ovale for the interventionalist.
McKenzie, Jeff A; Edwards, William D; Hagler, Donald J
2009-05-01
Patent foramen ovale (PFO) is an interatrial communication whose management is controversial. Several manufacturers have submitted protocols for Food and Drug Administration (FDA) approval of their PFO closure device. The purpose of this study was to define anatomy relevant to percutaneous PFO closure, validate the clinical observation that most PFOs contain little tissue rim at the aorta, comment on proposed closure guidelines, and to discuss approaches to PFO closure. From the Mayo Clinic Tissue Registry, five normal hearts with PFO were selected from each sex from the first 10 decades of life (n = 100). Measurements (mm) included PFO length, diameter, and distance from FO-superior vena cava (SVC) and FO-aortic annulus (AoAn). Patient age, weight, and height were obtained from autopsy reports, and body surface area (BSA) was calculated. PFO length and diameter increased with age (P = 0.029 and 0.001, respectively), and FO-SVC and FO-AoAn increased with BSA (P
TrapEase inferior vena cava filter placement: use of the subclavian vein.
Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A
2004-01-01
The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access and where combined long-term central venous catheter placement using the subclavian vein is desirable.
Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo
2016-01-01
OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898
Serial cardiac MRIs in adult Fontan patients detect progressive hepatic enlargement and congestion.
Lewis, Matthew J; Hecht, Elizabeth; Ginns, Jonathan; Benton, Joshua; Prince, Martin; Rosenbaum, Marlon S
2017-03-01
The progression of hepatic disease in adult Fontan patients is not well understood. They reviewed the experience with serial cardiac MRIs (CMR) in adult Fontan patients to determine if hepatic anatomic markers of prolonged Fontan exposure were present and if clinical predictors of progressive hepatic congestion could be identified. A retrospective cohort study of all adult Fontan patients who had undergone at least two CMRs was performed. Hepatic dimensions, inferior vena cava (IVC) size, right hepatic vein (RHV) size and spleen diameter were determined from images acquired at the time of clinically guided CMR. Two radiologists with expertise in hepatic imaging graded congestion and liver size independently using post-gadolinium contrast sequences. Twenty-seven patients met inclusion criteria. Over a mean time of 5.1 years between CMRs, there was a significant increase in mean lateral-medial hepatic dimension (P = .005), mean RHV diameter (P = .004), and mean splenic diameter (P = .001). Serial post-gadolinium imaging was available in 25/27 (93%) patients of which 15/27 (55%) showed evidence of progressive hepatic congestion across serial studies. Progressive hepatic congestion was associated with single ventricle ejection fraction (SVEF) less than 50% (P = .008), and larger indexed end-diastolic (EDVI) and end-systolic volume (ESVI). RHV diameter was the only anatomic variable significantly correlated with time from Fontan completion (P = .004). Serial CMRs detected progressive liver and hepatic vein enlargement in our cohort of adult Fontan patients over a mean time of 5.2 years. Progressive hepatic congestion occurs in a significant number of adult Fontan patients and may be associated with ventricular enlargement and decreased ventricular function by CMR. © 2016 Wiley Periodicals, Inc.
Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.
Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée
2012-10-01
We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.
Transection of the inferior vena cava from blunt thoracic trauma: case reports.
Peitzman, A B; Udekwu, A O; Pevec, W; Albrink, M
1989-04-01
Blunt thoracic trauma is a frequent cause of death in multiple trauma victims. Myocardial rupture may occur in up to 65% of patients who die with thoracic injuries. Two cases are presented with intrapericardial transection of the inferior vena cava, pericardial rupture, and myocardial rupture from blunt thoracic trauma. Both patients died.
Retrieval of Cement Embolus from Inferior Vena Cava After Percutaneous Vertebroplasty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athreya, S., E-mail: sathreya@stjoes.c; Mathias, N.; Rogers, P.
Percutaneous vertebroplasty is an accepted treatment for painful vertebral compression fractures caused by osteoporosis and malignant disease. Venous leakage of cement and pulmonary cement embolism have been reported complications. We describe a paravertebral venous cement leak resulting in the deposition of a cement cast in the inferior vena cava and successful retrieval of the cement embolus.
Latchana, Nicholas; Dowell, Joshua D.; Taani, Jamal Al; Michaels, Anthony; Elkhammas, Elmadhi; Black, Sylvester M.
2015-01-01
Inferior vena cava thrombosis is a rare occurrence after an orthotopic liver transplant that is associated with a high rate of retransplant and mortality. There is no consensus regarding the optimal therapeutic strategy. Surgical management, including thrombectomy with revision of the cavocaval anastomosis, has been described. With the use of endovascular therapies, several minimally invasive approaches are available that are effective and avoid the high morbidity associated with reoperative surgery. We describe our successful experience using an approach after a liver transplant in which the inferior vena cava thrombosis in a patient presenting with acute renal failure, anorexia, weight loss, and fatigue using an ultrasound-accelerated, catheter-directed thrombolysis platform in conjunction with systemic anticoagulation. PMID:24918871
Partial anomalous pulmonary venous connection to the superior vena cava.
Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto
2011-04-01
We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn
2015-08-01
Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.
Effect of pH on structure, function, and stability of mitochondrial carbonic anhydrase VA.
Idrees, Danish; Shahbaaz, Mohd; Bisetty, Krishna; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz
2017-02-01
Mitochondrial carbonic anhydrase VA (CAVA) catalyzes the hydration of carbon dioxide to produce proton and bicarbonate which is primarily expressed in the mitochondrial matrix of liver, and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis, and neuronal transmission. To understand the effect of pH on the structure, function, and stability of CAVA, we employed spectroscopic techniques such as circular dichroism, fluorescence, and absorbance measurements in wide range of pH (from pH 2.0 to pH 11.5). CAVA showed an aggregation at acidic pH range from pH 2.0 to pH 5.0. However, it remains stable and maintains its secondary structure in the pH range, pH 7.0-pH 11.5. Furthermore, this enzyme has an appreciable activity at more than pH 7.0 (7.0 < pH ≤ 11.5) with maximum activity at pH 9.0. The maximal values of k cat and k cat /K m at pH 9.0 are 3.7 × 10 6 s -1 and 5.5 × 10 7 M -1 s -1 , respectively. However, this enzyme loses its activity in the acidic pH range. We further performed 20-ns molecular dynamics simulation of CAVA to see the dynamics at different pH values. An excellent agreement was observed between in silico and in vitro studies. This study provides an insight into the activity of CAVA in the pH range of subcellular environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaber, Mohammad R., E-mail: raffatj@msn.co; Thomson, Matthew J.; Smith, Douglas C.
We describe percutaneous, translumbar placement of a 14-Fr dialysis catheter into an ascending lumbar vein to achieve tip position in an enlarged azygos vein. The patient had thrombosis of all traditional vascular sites, as well as the inferior vena cava. This catheter functioned well for 7 months before fatal catheter-related infection developed.
Quantum Material Properties of 4d and 5d Transition Metal Oxides and Potential Applications
2015-05-26
11 2009): 0. doi: 10.1103/PhysRevB.80.184505 Y. Liu, I. G. Deac, P. Khalifah, R. J. Cava, Y. A. Ying, P. Schiffer , K. D. Nelson. Possible observation...Yiqun A. Ying, Karl Nelson, Iosef G. Deac, Peter Schiffer , Peter Khalifah, Robert J. Cava, and Ying Liu, "Magneto electrical transport properties and
Morphology of splenocaval congenital portosystemic shunts in dogs and cats.
White, R N; Parry, A T
2016-01-01
To describe the anatomy of congenital portosystemic shunts involving the splenic vein communicating with the caudal vena cava at the level of the epiploic foramen. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Ninety-eight dogs and eight cats met the inclusion criteria of a congenital portosystemic shunt involving the splenic vein communicating with the prehepatic caudal vena cava plus recorded intra-operative mesenteric portovenography or computed tomography angiography and gross observations at surgery. All cases (both dogs and cats) had a highly consistent shunt that involved a distended gastrosplenic vein that communicated with the caudal vena cava at the level of the epiploic foramen via an anomalous left gastric vein. The morphology of the shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava and the subsequent development of preferential blood flow through an essentially normal portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the splenic vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory
2013-11-01
To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.
Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok
2016-05-01
To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.
Baumann, S; Becher, T; Giannakopoulos, K; Jabbour, C; Fastner, C; El-Battrawy, I; Ansari, U; Lossnitzer, D; Behnes, M; Alonso, A; Kirschning, T; Dissmann, R; Kueck, O; Stern, D; Michels, G; Borggrefe, M; Akin, I
2018-04-01
Pulmonary embolism (PE) is a frequently occurring complication in critically ill patients, and the simultaneous occurrence of PE and life-threatening bleeding is a therapeutic dilemma. Inferior vena cava filters (IVCF) may represent an important therapeutic alternative in these cases. The Angel® catheter (Bio2 Medical Inc., San Antonio, TX, USA) is a novel IVCF that provides temporary protection from PE and is implanted at bedside without fluoroscopy. The European Angel® Catheter Registry is an observational, multicenter study. In our German substudy, we investigated patients from three German hospitals and four intensive care units, who underwent Angel® catheter implantation between February 2016 and December 2016. A total of 23 critically ill patients (68 ± 9 years, 43% male) were included. The main indication for implantation was a high risk for or an established PE, combined with contraindications for prophylactic or therapeutic anticoagulation due to either an increased risk of bleeding (81%) or active bleeding (13%). The Angel® catheter was successfully inserted in all patients at bedside. No PE occurred in patients with an indwelling Angel® catheter. Clots with a diameter larger the 20 mm, indicating clot migration, were detected in 5% of the patients by cavography before filter retrieval. Filter retrieval was uneventful in all of our cases, while filter dislocation occurred in 3% of the patients. The German data from the multicenter European Angel® Catheter Registry show that the Angel® catheter is a safe and effective approach for critically ill patients with a high risk for the development of PE or an established PE, when an anticoagulation therapy is contraindicated.
Petridis, Ioannis; Miraglia, Roberto; Marrone, Gianluca; Gruttadauria, Salvatore; Luca, Angelo; Vizzini, Giovanni Battista; Gridelli, Bruno
2010-03-07
Transjugular intrahepatic portosystemic shunt (TIPSS) is considered a valid therapeutic option for the treatment of portal hypertension and its complications. The guidelines for this procedure have already been established on the basis of the normal vascular anatomy and of various technical radiological aspects. In some few rare cases, diagnosis of a congenital vascular anomaly can be made accidentally by interventional radiologists, making the procedure of the TIPSS placement extremely difficult or in some cases technically impossible. This report describes a rare vascular malformation characterized by the absence of the right superior vena cava and persistence of the left superior vena cava in a patient with a diagnosis of advanced liver cirrhosis who needed a TIPSS placement in order to control refractory ascites.
Archundia García, A; Gómez Alvarez, E; Ixcamparij Rosales, C; Blanco Canto, M; Hernández Ruiz, M A
2000-01-01
This is the diagnostic experiences as well as the surgical mode of treatment used in a 31 years old women suffering diversion of the inferior vena cava into the left atrium associated with atrial septal defect. The patient had been previously studied and operated thrice under conventional circumstances at different institutions in order to solve the septal defect. The hemodynamic solution had not been reached due to a missing pathological definition. The cineangiogram through the saphenous vein specified the left atrium form the inferior vena cava. Some considerations are made on the surgical methods used for the fourth operation, and in regard of the fact that the patient refused blood transfusion because of religious convictions (Jehova Witness).
Modified repair of mixed anomalous pulmonary venous connection.
van Son, J A; Hambsch, J; Mohr, F W
1998-05-01
A modified repair technique is reported for mixed total or partial anomalous pulmonary venous connection with the right superior pulmonary vein connecting to the superior vena cava, the right inferior pulmonary vein to the right atrium or left atrium, and the left pulmonary veins to the coronary sinus. The superior vena cava is transected above the highest right superior pulmonary vein, its cephalad end is anastomosed to the right atrial appendage, and a pericardial baffle is constructed between the cardiac ostium of the superior vena cava, the ostium of the right inferior pulmonary vein, and the left atrium, including the coronary sinus, which is unroofed. The reported technique may be valuable to avoid pulmonary venous obstruction in complex mixed forms of total or partial anomalous pulmonary venous connection.
Kuo, William T; Robertson, Scott W
2015-01-01
A 46-year-old woman underwent inferior vena cava filter placement before bariatric surgery and returned within 6 months for routine removal. She complained of a 1-week history of severe chest pain, and during retrieval, two fractured filter components were identified including one arm in the right ventricle. The filter body and one fragment were successfully retrieved, but the fragment in the right ventricle was refractory to percutaneous retrieval. During open-heart surgery, the fragment was found traversing through the ventricular wall resulting in cardiac tamponade. Electron microscopic fragment analysis revealed high-cycle metal fatigue indicating the filter design failed to withstand this patient's natural inferior vena cava biomechanical motions. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Duebener, Lennart F; Hagino, Ikuo; Schmitt, Katharina; Sakamoto, Takahiko; Stamm, Christof; Zurakowski, David; Schäfers, Hans-Joachim; Jonas, Richard A
2003-04-01
Retrograde cerebral perfusion (RCP) is used in some centers during aortic arch surgery for brain protection during hypothermic circulatory arrest. It is still unclear however whether RCP provides adequate microcirculatory blood flow at a capillary level. We used intravital microscopy to directly visualize the cerebral capillary blood flow in a piglet model of RCP. Twelve pigs (weight 9.7 +/- 0.9 kg) were divided into two groups (n = 6 each): deep hypothermic circulatory arrest (DHCA) and RCP. After the creation of a window over the parietal cerebral cortex, pigs underwent 10 minutes of normothermic bypass and 40 minutes of cooling to 15 degrees C on cardiopulmonary bypass ([CPB] pH-stat, hemocrit 30%, pump flow 100 mL x kg(-1) x min(-1)). This was followed by 45 minutes of DHCA and rewarming on CPB to 37 degrees C. In the RCP group the brain was retrogradely perfused (pump flow 30 mL x kg(-1) x min(-1)) during DHCA through the superior vena cava after inferior vena cava occlusion. Plasma was labeled with fluorescein-isothiocyanate-dextran for assessing microvascular diameter and functional capillary density (FCD), defined as total length of erythrocyte-perfused capillaries per observation area. Cerebral tissue oxygenation was determined by nicotinamide adenine dinucleotide hydrogen (NADH) autofluorescence, which increases during tissue ischemia. During normothermic and hypothermic antegrade cerebral perfusion the FCD did not significantly change from base line (97% +/- 14% and 96% +/- 12%, respectively). During retrograde cerebral perfusion the FCD decreased highly significantly to 2% +/- 2% of base line values (p < 0.001). Thus there was no evidence of significant capillary blood flow during retrograde cerebral perfusion. The microvascular diameter of cerebral arterioles that were slowly perfused significantly decreased to 27% +/- 6% of base line levels during RCP. NADH fluorescence progressively and significantly increased during RCP, indicating poorer tissue oxygenation. At the end of retrograde cerebral perfusion there was macroscopic evidence of significant brain edema. RCP does not provide adequate cerebral capillary blood flow and does not prevent cerebral ischemia. Prolonged RCP induces brain edema. However, there might be a role for a short period of RCP to remove air and debris from the cerebral circulation after DHCA because retrograde flow could be detected in cerebral arterioles.
Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound
2017-10-01
AWARD NUMBER: W81XWH-15-1-0709 TITLE: Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound PRINCIPAL INVESTIGATOR: Donald...No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for... information . Send comments regarding this burden estimate or any other aspect of this collection of information , including suggestions for reducing this
Nephroblastoma with right atrial extension: preoperative diagnosis and management.
Vaughan, E D; Crosby, I K; Tegtmeyer, C J
1977-04-01
A 14-year-old black boy, with a large nephroblastoma of the right kidney, had preoperative identification of inferior vena cava and right atrial involvement. Renal arteriography revealed linear arterial channels in the anatomic distribution of the inferior vena cava and venography revealed total caval occlusion and a right atrial mass. Radical excision, using a cardiopulmonary bypass, resulted in a 6-month postoperative survival.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goo, Dong Erk, E-mail: degoo@hosp.sch.ac.kr; Kim, Yong Jae; Choi, Deuk Lin
2011-02-15
A 67-year-old woman with end-stage renal disease presented with profound edema of both breasts. The presence of a patent hemodialysis basilic transposition fistula and superior vena cava obstruction (SVC), due to fibrosing mediastinitis, was demonstrated by the use of fistulography. Endovascular treatment with a balloon and stent caused immediate resolution of the breast edema.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.
2004-01-15
We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.
Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran
2015-01-01
Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846
Nyakas, Csaba; Felszeghy, Klára; Szabó, Róbert; Keijser, Jan N; Luiten, Paul G M; Szombathelyi, Zsolt; Tihanyi, Károly
2009-01-01
Vinpocetine (ethyl-apovincaminate, Cavinton), a synthetic derivative of the Vinca minor alkaloid vincamine, has been used now for decades for prevention and treatment of cerebrovascular diseases predisposing to development of dementia. Both vinpocetine and its main metabolite cis-apovincaminic acid (cAVA) exert a neuroprotective type of action. Bilateral N-methyl-D-aspartate (NMDA)-induced neurodegeneration in the entorhinal cortex of rat was used as a dementia model to confirm the neuroprotective action of these compounds in vivo. NMDA-lesioned rats were treated 60 min before lesion and throughout 3 postoperative days with a 10 mg/kg intraperitoneal dose of vinpocetine or cAVA. Behavioral tests started after termination of drug treatment and consisted of novel object recognition, social discrimination, and spontaneous alternation in a Y-maze, and spatial learning in the Morris water maze. At the end of behavioral testing brains were perfused with fixative and the size of the excitotoxic neuronal lesion and that of microglial activation around the lesion were assayed quantitatively on brain sections immunostained for neuron-specific nuclear protein (NeuN) and integrin CD11b, respectively. Entorhinal NMDA lesions impaired recognition of novel objects and the new social partner, and suppressed spontaneous alternation and spatial learning performance in the Morris maze. Both vinpocetine and cAVA effectively attenuated the behavioral deficits, and significantly decreased lesion size and the region of microglia activation. Both lesion-induced attention deficit and learning disabilities were markedly alleviated by vinpocetine and cAVA. The morphological findings corroborated the behavioral observations and indicated reduced lesion size and microglia activation especially after vinpocetine treatment which supports an in vivo neuroprotective mode of action of vinpocitine and a less potent action of cAVA.
Inferior Vena Cava Filters in Elderly Patients with Stable Acute Pulmonary Embolism.
Stein, Paul D; Matta, Fadi; Hughes, Mary J
2017-03-01
Patients aged >60 years with pulmonary embolism who were stable and did not require thrombolytic therapy were shown to have a somewhat lower in-hospital all-cause mortality with vena cava filters. In this investigation we further assess mortality with filters in stable elderly patients. In-hospital all-cause mortality according to use of inferior vena cava filters was assessed from the National (Nationwide) Inpatient Sample, 2003-2012, in: 1) All patients with pulmonary embolism; 2) All with pulmonary embolism who had none of the comorbid conditions listed in the Charlson Comorbidity Index; 3) Patients with a primary (first-listed) diagnosis of pulmonary embolism, and 4) Patients with a primary diagnosis of pulmonary embolism and none of the comorbid conditions listed in the Charlson Comorbidity Index. From 2003-2012, 2,621,575 stable patients with pulmonary embolism were hospitalized in the US. Patients aged >80 years showed lower mortality with vena cava filters (all pulmonary embolism, 6.1% vs 10.5%; all pulmonary embolism with no comorbid conditions, 3.3% vs 6.3%; primary pulmonary embolism, 4.1% vs 5.7%; primary pulmonary embolism with no comorbid conditions, 2.1% vs 3.7%; all P <.0001). In the all-patient category, patients aged 71-80 years showed somewhat lower mortality with filters, 6.3% vs 7.4% (P <.0001), and those without comorbid conditions, 2.5% vs 2.8% (P = .04). Those aged 71-80 years with primary pulmonary embolism, irrespective of comorbid conditions, did not show lower mortality with filters. At present, in the absence of a randomized controlled trial, it seems prudent to consider a vena cava filter in very elderly (aged >80 years) stable patients with acute pulmonary embolism. Copyright © 2016 Elsevier Inc. All rights reserved.
Modeling Flow Past a Tilted Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Wang, S L
Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside amore » model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.« less
ENDO, Natsumi; NAGAI, Kiyosuke; TANAKA, Tomomi; KAMOMAE, Hideo
2012-01-01
Abstract The present study was designed to assess progesterone profiles at the secreted (caudal vena cava) and circulating levels (jugular vein) and luteinizing hormone (LH) secretion pattern in lactating and non-lactating cows with reference to feeding. Four lactating and four non-lactating cycling Holstein cows were examined. Blood samples were collected simultaneously from the caudal vena cava (via a catheter inserted from the coccygeal vein) and the jugular vein every 15 min for 12 h (0500–1700 h) during the functional luteal phase. Cows were fed 50% of the daily diet 6 h after the start of blood sampling. During the 12-h sampling period, mean progesterone concentrations in the caudal vena cava did not differ between lactating and non-lactating cows (49.0 ± 2.9 and 53.3 ± 3.7 ng/ml; mean ± SE), whereas mean progesterone concentrations in the jugular vein in lactating cows were higher than those in non-lactating cows (6.4 ± 0.1 and 5.6 ± 0.1 ng/ml, P < 0.001). Lactating cows had a higher frequency of LH pulses than non-lactating cows (7.0 ± 0.7 and 4.3 ± 0.9 pulses/12 h, P<0.05). The influence of feeding was not observed on LH profiles but was observed on progesterone profiles in both veins. Progesterone concentrations in the caudal vena cava increased after feeding in both groups. Progesterone concentrations in the jugular vein decreased after feeding in lactating cows but not in non-lactating cows. These results indicate the difference in feeding-related changes in progesterone dynamics between lactating and non-lactating cows. PMID:23171608
A case of residual inferior sinus venosus defect after ineffective surgical closure.
Uga, Sayuri; Hidaka, Takayuki; Takasaki, Taiichi; Kihara, Yasuki
2014-10-03
A 38-year-old woman presented with cyanosis and heart failure 34 years after patch closure of an atrial septal defect and partial anomalous pulmonary venous connection. CT and cardiac catheterisation showed a residual defect that caused right-to-left shunting. The patch almost blocked the inferior vena cava from the right atrium, resulting in uncommon drainage of the inferior vena cava into the left atrium. Other anomalies included the coronary-to-pulmonary artery fistula and duplicate inferior vena cava with dilated azygos venous system. A second surgery was performed, and we confirmed an inferior sinus venosus defect, which is rare and can be misdiagnosed. The ineffective patch closure had caused a haemodynamic status that rarely occurs. We describe the diagnostic process and emphasise the importance of correctly understanding the entity. 2014 BMJ Publishing Group Ltd.
Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk
Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less
Meandering Right Pulmonary Vein to the Left Atrium and Inferior Vena Cava
Tortoriello, Tia A.; Vick, G. Wesley; Chung, Taylor; Bezold, Louis I.; Vincent, Julie A.
2002-01-01
We report a case of a healthy, asymptomatic 6-year-old boy in whom an anomalous right pulmonary vein was noted to drain into both the inferior vena cava and left atrium in association with findings consistent with scimitar syndrome. The anomalous pulmonary vein took a very circuitous route through the lungs before draining into the left atrium, a condition previously termed “meandering pulmonary vein.” To aid in the diagnosis, cardiovascular magnetic resonance imaging and magnetic resonance angiography were used to delineate this complex course and the connection of the anomalous pulmonary vein. To our knowledge, this is the 1st reported case of a meandering pulmonary vein with dual drainage to the inferior vena cava and left atrium in association with other anomalies. (Tex Heart Inst J 2002;29:319–23) PMID:12484618
Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R
2007-03-01
Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.
Blood Oxygen Conservation in Diving Sea Lions: How Low Does Oxygen Really Go
2015-09-30
5 6 7 0 20 40 60 80 100 % H b Sa tu ra tio n (S O2 ) Time into Dive (min) Arterial SO2 PostVenaCava SO2 AntVenaCava SO2 3 Figure 2. Rate of...change in posterior venacaval hemoglobin saturation ( SO2 ) in relation to stroke rate during descent, bottom phase, and ascent of all dives of sea
Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dursun, Memduh, E-mail: memduhdursun@yahoo.com; Sarvar, Sadik; Cekrezi, Bledi
2008-07-15
Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.
Venous outflow obstruction and portopulmonary hypertension after orthotopic liver transplantation
Aguirre-Avalos, Guadalupe; Covarrubias-Velasco, Marco Antonio; Rojas-Sánchez, Antonio Gerardo
2013-01-01
Patient: Female, 54 Final Diagnosis: Suprahepatic inferior vena cava anastomosis stricture Symptoms: Ascites • fatigue • lower limb edema • hepatomegaly Medication: — Clinical Procedure: — Specialty: Transplantology • Critical Care Medicine Objective: Unusual clinical course Background: Suprahepatic inferior vena cava anastomosis stricture is an unusual vascular complication after orthotopic liver transplantation with the “piggyback” technique. Clinical manifestations are dependent upon the severity of the stenosis. Portopulmonary hypertension after orthotopic liver transplantation is a complication that carries high mortality due to cardiopulmonary dysfunction. The pathogenesis of pulmonary vascular disorders after orthotopic liver transplantation remains uncertain. Case Report: We report a case of acute right heart pressure overload after surgical correction of the suprahepatic inferior vena cava anastomotic stricture in a 54-year-old woman who had preexisting pulmonary arterial hypertension associated with portal hypertension after orthotopic liver transplantation. Twenty months posttransplantation, she developed fatigue and progressive ascites. On admission, the patient had hepatomegaly, ascites, and lower limb edema. Symptoms in the patient developed gradually over time. Conclusions: Recurrent portal hypertension by vascular complications is a cause of pulmonary arterial hypertension after orthotopic liver transplantation. Clinical manifestations of suprahepatic inferior vena cava anastomotic stenosis are dependent upon their severity. Sildenafil is an effective drug for treatment of pulmonary arterial hyper-tension after portal hypertension by vascular complications. PMID:24046802
Guo, Zhe; He, Wei; Hou, Jing; Li, Tong; Zhou, Hua; Xu, Yuan; Xi, Xiuming
2014-09-01
To approach the evaluative effect of respiratory variation of superior vena cava peak flow velocity measured using transthoracic echocardiography (TTE) on fluid responsiveness in patients with mechanical ventilation. A prospective cohort study was conducted. All mechanical ventilated critically ill patients whose fluid therapy was planned due to hypovolemia in Department of Critical Care Medicine of Beijing Tongren Hospital of Capital Medical University from April 2011 to April 2013 were enrolled. Volume expansion was performed with 500 mL Linger solution within 30 minutes. Patients were classified as responders if pulse pressure variation (PPV) increased ≥ 13% before volume expansion. The respiratory variation in superior vena cava peak velocity was calculated as the difference between maximum and minimum values of velocity in peak A, peak S and peak D over a single respiratory circle, and their variations (ΔA, ΔS, ΔD) were also calculated. The receiver operating characteristic curve (ROC curve) was plotted to assess the evaluative effect of respiratory variation of superior vena cava peak velocity on fluid responsiveness. Twenty-seven patients were enrolled in this study. Volume expansion increased PPV ≥ 13% happened in 14 patients (responders). The velocity of superior vena cava in peak A, peak S, peak D was significantly increased after volume expansion compared with that before volume expansion in responders [peak A (cm/s): 34.6 ± 2.2 vs. 31.3 ± 2.1, t=-2.493, P=0.027; peak S (cm/s): 39.1 ± 1.3 vs. 35.3 ± 2.1, t=-2.564, P=0.024; peak D (cm/s): 28.1 ± 1.2 vs. 23.3 ± 1.4, t=-4.995, P=0.000], but there was no significant difference in ΔA, ΔS and ΔD between before and after volume expansion. The ΔA, ΔS and ΔD were positively correlated with PPV (r=0.040, P=0.854; r=0.350, P=0.074; r=0.749, P=0.000). The area under ROC curve (AUC) of peak S was 0.36 [95% confidence interval (95%CI): 0.11-0.52], but the AUC of ΔS was 0.68 (95%CI 0.47-0.89), the AUC of peak D was 0.41 (95%CI 0.19-0.63), but the AUC of ΔD was 0.95 (95%CI 0.86-1.00), so the aberration rate of superior vena cava in respiration was better than the flow rate in superior vena cava. When the cut-off value of ΔS was 20.7% for predicting fluid responsiveness, the sensitivity was 78.6% and the specificity was 61.5%. When the cut-off value of ΔD was 12.7% for predicting fluid responsiveness, the sensitivity was 92.0% and the specificity was 92.3%. Respiratory variations in superior vena cava peak velocity measured by TTE could assess fluid responsiveness in patients with mechanical ventilation.
Characterization and Utilization of Opiate-Like Hibernation Factors.
1993-12-08
duodenum, and both kidneys were dissected free, along with the abdominal aorta and the inferior vena cava . The chest was then opened, and the heart, and...lungs along with the aorta and the superior and inferior vena cava (IVC), were dissected free. The trachea was transected and an endotracheal tube was...pericardial incision was extended inferiorly, exposing the anterior aspect of the left atrium and the left -Page 36 - inferior pulmonary vein. The
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.
Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.
Masi, Marco; Moeini, Seyed Arash; Boari, Angela; Cimmino, Alessio; Vurro, Maurizio; Evidente, Antonio
2018-07-01
Cavoxin is a tetrasubstituted phytotoxic chalcone and cavoxone is the corresponding chroman-4-one, both produced in vitro by Phoma cava, a fungus isolated from chestnut. Cavoxin showed biofungicide potential against fungal species responsible for food moulding. Therefore, cavoxin has potential to be incorporated into biopolymer to generate 'intelligent food packaging'. To reach this objective, large-scale production of cavoxin by P. cava fermentation needs to be optimized. A rapid and efficient method for cavoxin analysis, as well as of cavoxone, in the fungal culture filtrates and the corresponding organic extracts is the first experimental step. Thus, a HPLC method was developed and applied to quantify cavoxin and cavoxone production in two different fungal culture conditions. The analysis proved that cavoxin production in stirred culture filtrates is significantly higher than in static ones.
Situs ambiguous in a schoolchild
Tortajada, Miguel; Moreno, Miriam; Gracia, Miguel; Sanchis, Amparo
2010-01-01
We report the case of a 9-year-old child with asthma, atopic dermatitis and allergic rhinoconjunctivitis due to house dust mites, in whom a routine chest x-ray identified by chance abnormal organ position, such as the stomach located on the right side. Abdominal ultrasonography indicated a centralised liver, with polysplenia on the right side and an inferior cava vein located to the left of the aorta with no interruption. Ultrasonography did not show heart defects. Magnetic resonance imaging (MRI) of the abdomen was performed that showed a short pancreas, with no neck, body and tail in it, and a left inferior vena cava with normal outlet of the renal veins, and absence of the intrahepatic part of the inferior vena cava, that was replaced by the left hemiazygos vein. Spinal cord MRI revealed dorsal syringomelia. In view of the results obtained, the diagnosis of situs ambiguous was established. PMID:22121394
Jain, Ankur
2014-01-01
We report a case of a 60-year-old lady who presented with bilateral lower limb swelling and a thyroid swelling with clinical features consistent with thyrotoxicosis. Investigations revealed the presence of a thrombus in bilateral external, internal iliac veins, and inferior vena cava extending up to its infrahepatic part. Hormone profile and radioiodine uptake scan confirmed the diagnosis of Graves’ disease. Further workup revealed the presence of antiphospholipid antibodies (confirmed after a repeat test at 12 weeks). The patient was treated with antithyroid drugs and anticoagulants. The patient improved with normalization of thyroid function and partial recanalization of the infrahepatic part of inferior vena cava. Hyperthyroidism has been implicated as a potential hypercoagulable state; however, the association of Graves’ disease with antiphospholipid antibody syndrome is limited to isolated case reports. This case highlights a new mechanism underlying hypercoagulability associated with Graves’ disease. PMID:24812529
Osteodiskitis of Lumbar Spine Due to Migrated Fractured Inferior Vena Cava Filter.
Aoun, Salah G; Bedros, Nicole; El Ahmadieh, Tarek Y; Kreck, Jake; Mehta, Nikhil; Al Tamimi, Mazin
2018-05-01
Venous thromboembolism can be a significant cause of morbidity in the trauma population. Medical and surgical specialties have been pushing the indication for prophylactic filter placement. A 36-year-old man presented with axial lower back pain with a radicular right L2 component after lifting a heavy object. He had a history of penetrating brain trauma 3 years prior, with placement of a prophylactic inferior vena cava filter. His radiograph, computed tomography, and magnetic resonance imaging of the lumbar spine showed fracture of his filter, with migration of the fractured fragment through the inferior vena cava and into the L2-L3 disk space, and surrounding bony lysis and severe osteodiskitis. He was treated medically with intravenous and then oral antibiotics and improved clinically and radiographically. Conservative use of filter devices and early retrieval once their indication expires are paramount to avoid unnecessary complications. Copyright © 2018 Elsevier Inc. All rights reserved.
Double aortic arch and persistent left vena cava in a white lion cub (Panthera leo).
Goldin, J P; Lambrechts, N E
1999-03-01
A 4-mo-old female white lion (Panthera leo) cub was presented with a 2-wk history of persistent postprandial regurgitation, mild dyspnea, and poor weight gain. The cub was weak and thin but otherwise alert. Survey and contrast radiography revealed a large dilated esophagus cranial to the heart base, with an esophageal filling defect present at the level of the fourth thoracic vertebra. A vascular ring anomaly was tentatively diagnosed. Exploratory thoracotomy revealed a double aortic arch and a persistent left vena cava. The left aortic arch was ligated and divided, and recovery was uneventful. A single episode of regurgitation occurred within the first postoperative month, and the cub gained 5.5 kg in weight during the same time period. Neither double aortic arch nor persistent left vena cava has been reported in a nondomestic felid.
[Surgical treatment of partial anomalous pulmonary venous drainage].
Cabrera, A; Idígoras, G; Sarrionandía, M J; Martínez, P; Rumoroso, J R; Alcíbar, J
1996-02-01
We studied all patients operated for partial anomalous pulmonary venous drainage and half-time follow-up. Twenty-eight patients with a mean age of 5 +/- 5 years (5 patients were less than 1 year old). There were sixteen male and twelve female patients. Thirteen patients were symptomatic (47%). The drainage was to the superior vena cava in thirteen cases, to the inferior vena cava in eight cases, to the right atrium in five cases, mixed (to the superior vena cava and to the inferior vena cava) in one case and to the innominate vein in one patient. The diagnosis was made through echocardiography and catheterization in 25 patients, whereas nuclear magnetic resonance was performed in the last five patients. All cases were corrected through medium thoracotomy, except for the single case in which the drainage was to the innominate vein). In 27 patients, the pulmonary veins were guided to the left atrium through an enlarged present atrial septal defect or through a created atrial septal defect. In one case a direct connection was performed from the veins to the left atrium. After the surgical correction, all patients underwent a color-coded Doppler echocardiography study and a nuclear magnetic resonance study was performed in five patients. Twenty-seven patients survived after surgical correction. The patient with a mixed drainage developed an obstruction of the superior vena cava, the pressure gradient was 9 mmHg. He required a second surgical procedure followed with angioplasty on two occasions during a six month period. Two patients showed an ectopic atrial rhythm at some late time. The patient who died was one month old and had an associated pulmonary parenchymal sequestration. Partial anomalous venous connection is a congenital heart disease which has an easy surgical correction. Complications may arise after the surgical correction, among them obstruction of the superior vena cava and arrythmias are most frequently found. Obstruction is present when 50% of the caval area is occupied by the patch. The arrythmias occur following all surgical techniques. In order to decrease the arrythmias it is necessary to perform a good hemosthasis at the site of the patch, to leave the sinus node free of compression and to perform the atrial incision at the posterior wall. The diagnosis and the follow-up can be performed with non-invasive procedures.
[Value of x-ray computed tomography in the study of the inferior vena cava in urologic practice].
Barré, C; Vialle, M; Rieux, D; Caron-Poitreau, C; Soret, J Y; Rognon, M
1985-01-01
The CT scan provides a reliable evaluation of the inferior vena cava, especially since the development of second and third generation scanners. It can readily detect congenital malformations and obstructive anomalies complicating renal cancer and it is also able to determine the tumoral or thrombotic nature of the venous obstruction. This excellent definition of the vessel reduces the indications for caval angiography to a few exceptional cases.
Cardiac Pressure Changes with Venous Gas Embolism and Decompression
1994-04-01
inferior vena cava via the left femoral vein for venous access. Airway pressure was measured from a connector at the proximal end of the endotracheal...Hartley), mount- ed in a 7-9 m acrylic cuff was surgically placed around the inferior vena cava via laparotomy, approximately 1-2 cm above the renal...pressure and decreasing cardiac output which in return may cause the left atrial pressure to fall below that of the right atrium . Recent studies have
Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact
2001-03-01
inferior vena cava to the right auricle. From the right auricle, the blood is passed into the right ventricle. The right ventricle pumps the blood...the rib and vertebrae is modeled with two beam elements. To create the subcoastal angle, vertical cartilaginous connections at the inferior edge of...brachiocephalic aorta, the aorta, pulmonary arteries and veins, internal jugular veins, brachial veins, and superior vena cava . These vessels are modeled
Permanent right ventricular pacing through an anomalous left superior vena cava.
Amikam, S; Lemer, J; Riss, E
1977-01-01
A persistent left superior vena cava can complicate the implantation of a transvenous pacemaker. In a patient who required a permanent pacemaker, this venous anomaly was discovered during the insertion of the electrode but it did not prevent long-term right ventricular pacing. This was achieved after the electrode had been manipulated through the coronary sinus and right atrium. A plan of management is proposed for dealing with this unexpected problem. Images PMID:601745
Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.
Hoffer, Eric K; Mueller, Rebecca J; Luciano, Marcus R; Lee, Nicole N; Michaels, Anne T; Gemery, John M
2013-08-01
To evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter. A retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59% were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86% of patients; 14% were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records. Mean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3%). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4%). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8%) at a mean of 731 days revealed a single (0.3%) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5%), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4%) at a mean 757 days. The Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.
Morphology of congenital portosystemic shunts involving the right gastric vein in dogs.
White, R N; Parry, A T
2015-07-01
To describe the anatomy of congenital portosystemic shunts involving the right gastric vein in dogs. Retrospective review of a consecutive series of dogs managed for congenital portosystemic shunt. Twenty-two dogs met the inclusion criteria of a congenital portosystemic shunt involving the right gastric vein with recorded intraoperative mesenteric portovenography or computed tomography angiography and gross observations at the time of surgery. Of these, 20 (91%) had a shunt that entered the pre-hepatic caudal vena cava at the level of the epiploic foramen and two (9%) had a shunt that entered the post-hepatic caudal vena cava at the level of the diaphragm. Shunts entering the pre-hepatic caudal vena cava could be further classified into three consistent subdivisions. The morphology of each shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava, the presence or absence of an abnormal communication between the splenic, left gastric and portal veins and the subsequent development of preferential blood flow through essentially normal portal vessels within the portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the right gastric vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.org; Mueller, Rebecca J.; Luciano, Marcus R.
PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinicalmore » follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.« less
Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.
2013-01-01
Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880
Levin, D L; Mills, L J; Weinberg, A G
1979-08-01
The prostaglandin synthetase inhibitor indomethacin was given orally or intravenously to pregnant ewes. This resulted in a significant rise in the fetal pulmonary-to-systemic arterial mean blood pressure difference across the ductus arteriosus, presumably secondary to constriction of the ductus arteriosus. In five experiments the pressure difference could be promptly but temporarily reversed by the administration of prostaglandin E1 (PGE1) into the fetal inferior vena cava. Fetal lungs from study and control animals were fixed by perfusion at measured pulmonary arterial mean blood pressure, and fifth-generation resistance vessels were studied. The medial width/external diameter ratio was significantly increased in the study vs the control lungs due to increased smooth muscle and decreased external diameter. In addition, study fetuses had acute degenerative myocardial changes in the tricuspid valve papillary muscles, the right ventricular free wall and the interventricular septum. Similar changes were not seen in control fetuses. Indomethacin administration during pregnancy causes constriction of the fetal ductus arteriosus, fetal pulmonary arterial hypertension, and right ventricular damage. If severe, this may cause rapid fetal death. If less severe, in the newborn infant, this mechanism may be one cause of persistent pulmonary hypertension due to vasoconstriction and increased pulmonary arterial smooth muscle and/or tricuspid insufficiency due to papillary muscle infarction.
Karahan, Oguz; Kutas, H Barıs; Gurbuz, Orcun; Tezcan, Orhan; Caliskan, Ahmet; Yavuz, Celal; Demirtas, Sinan; Mavitas, Binali
2016-10-01
Deep venous thrombosis (DVT) is a life-threatening and morbid pathology. This study aimed to investigate the efficacy of an early thrombolysis procedure using a rotator thrombolysis device. Sixty-seven patients with acute proximal DVT were enrolled in the study. Patients' data were recorded retrospectively. Initially, an infrarenal retrievable vena cava filter was placed through the femoral vein. Then, a rotator thrombolysis device and a thrombolytic agent injection were applied to the occluded segments of the deep veins by puncturing the popliteal vein. The identified reasons were trauma (43.3%), pregnancy (20.9%), undiagnosed (11.9%), major surgical operation (10.5%), immobilization (7.5%), and malignancy (5.9%). Immediate total recanalization was conducted in all patients, and the leg diameters returned to normal ranges in the early postoperative period. Hospital mortality or severe complications were not detected. New thrombolytic devices seem to reduce in-hospital mortality risks and may potentially decrease post-thrombotic morbidity. © The Author(s) 2015.
Thakali, Keshari; Galligan, James J; Fink, Gregory D; Gariepy, Cheryl E; Watts, Stephanie W
2008-07-01
Heterodimerization of G-protein coupled receptors can alter receptor pharmacology. ET A and ET B receptors heterodimerize when co-expressed in heterologous expression lines. We hypothesized that ET A and ET B receptors heterodimerize and pharmacologically interact in vena cava from wild-type (WT) but not ET B receptor deficient (sl/sl) rats. Pharmacological endothelin receptor interaction was assessed by comparing ET-1-induced contraction in rings of rat thoracic aorta and thoracic vena cava from male Sprague Dawley rats under control conditions, ET A receptor blockade (atrasentan, 10 nM), ET B receptor blockade (BQ-788, 100 nM) or ET B receptor desensitization (Sarafotoxin 6c, 100 nM) and ET A plus ET B receptor blockade or ET A receptor blockade plus ET B receptor desensitization. In addition, similar pharmacological ET receptor antagonism experiments were performed in rat thoracic aorta and vena cava from WT and sl/sl rats. ET A but not ET B receptor blockade or ET B receptor desensitization inhibited aortic and venous ET-1-induced contraction. In vena cava but not aorta, when ET B receptors were blocked (BQ-788, 100 nM) or desensitized (S6c, 100 nM), atrasentan caused a greater inhibition of ET-1-induced contraction. Vena cava from WT but not sl/sl rats exhibited similar pharmacological ET receptor interaction. Immunocytochemistry was performed on freshly dissociated aortic and venous vascular smooth muscle cells to determine localization of ET A and ET B receptors. ET A and ET B receptors qualitatively co-localized more strongly to the plasma membrane of aortic compared to venous vascular smooth muscle cells. Our data suggest that pharmacological ET A and ET B receptor interaction may be dependent on the presence of functional ET B receptors and independent of receptor location.
Patterns of anomalous pulmonary venous drainage.
Snellen, H A; van Ingen, H C; Hoefsmit, E C
1968-07-01
All of our cases of abnormal pulmonary venous connections collected to the middle of 1965 and verified at surgery or autopsy have been reviewed by means of diagrams and tabulations, using a specially devised code to facilitate the survey. The material consisted of 52 autopsy cases (half of them obtained after surgery) and the cases of 72 patients who survived operation. The postmortem group was much younger than the surgical group and differed also from the latter by showing male preponderance as well as relatively many instances of total abnormal pulmonary venous connection and frequently associated cardiac anomalies. Partial anomalous connection of right pulmonary veins was 10 times more frequent than that of the left pulmonary veins. This was caused by (1) the frequent drainage of some of the right pulmonary veins into the junctional area between right atrium and superior vena cava in the presence of normal left pulmonary veins, and (2) the complete absence of isolated left pulmonary venous connection to the right atrium. Abnormal connection of solitary pulmonary veins was always effected to the most proximal venous structure among the four possible ones which are derived from the main embryonic channels (superior vena cava and inferior vena cava on the right side, and left superior vena cava and coronary sinus on the left side). Common pulmonary veins from one lung also drained in accordance with this proximity rule, if this may be taken to apply also to the drainage of right pulmonary veins into the right atrium. The one exception in our material was the drainage of all right pulmonary veins into the portal venous system. Total abnormal pulmonary venous connection may be found with all structures mentioned, but most frequently with the left superior vena cava, or coronary sinus, or both, usually by way of a common pulmonary vein. In a few cases however, drainage into different sites, all of them abnormal, did occur. Then again the proximity rule seemed to apply. A tentative embryological explanation is given for the patterns described.
Lu, Hou Tee; Chong, Jen Lim; Othman, Norliza; Vendargon, Simon; Omar, Shamsuddin
2016-05-03
Renal cell carcinoma is a potentially lethal cancer with aggressive behavior and it tends to metastasize. Renal cell carcinoma involves the inferior vena cava in approximately 15% of cases and it rarely extends into the right atrium. A majority of renal cell carcinoma are detected as incidental findings on imaging studies obtained for unrelated reasons. At presentation, nearly 25% of patients either have distant metastases or significant local-regional disease with no symptoms that can be attributed to renal cell carcinoma. A 64-year-old Indian male with a past history of coronary artery bypass graft surgery, congestive heart failure, and diabetes mellitus complained of worsening shortness of breath for 2 weeks. Incidentally, a transthoracic echocardiography showed a "thumb-like" mass in his right atrium extending into his right ventricle through the tricuspid valve with each systole. Abdomen magnetic resonance imaging revealed a heterogenous lobulated mass in the upper and mid-pole of his right kidney with a tumor extending into his inferior vena cava and right atrium, consistent with our diagnosis of advanced renal cell carcinoma which was later confirmed by surgical excision and histology. Radical right nephrectomy, lymph nodes clearance, inferior vena cava cavatomy, and complete tumor thrombectomy were performed successfully. Perioperatively, he did not require cardiopulmonary bypass or deep hypothermic circulatory arrest. He had no recurrence during the follow-up period for more than 2 years after surgery. Advanced extension of renal cell carcinoma can occur with no apparent symptoms and be detected incidentally. In rare circumstances, atypical presentation of renal cell carcinoma should be considered in a patient presenting with right atrial mass detected by echocardiography. Renal cell carcinoma with inferior vena cava and right atrium extension is a complex surgical challenge, but excellent results can be obtained with proper patient selection, meticulous surgical techniques, and close perioperative patient care.
Shen, O; Valsky, D V; Messing, B; Cohen, S M; Lipschuetz, M; Yagel, S
2011-02-01
Agenesis of the ductus venosus (ADV) is a rare condition in which there are two variants of umbilical vein drainage: intrahepatic shunt or extrahepatic (portosystemic) shunt. It has been posited that the extrahepatic variant carries a poorer prognosis. However, in the absence of associated anomalies there is still a wide variation in outcome. We evaluated the portal system in cases of ADV and aimed to identify parameters that might predict outcome. We conducted a retrospective study of cases of ADV with extrahepatic shunt that had been examined in two centers, and collected new cases prospectively. The route of the shunt was depicted using two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. In an attempt to characterize portal system and shunt developmental variations and their possible impact on outcome, the diameter of the shunt was compared with the diameter of the umbilical vein and the entire portal vasculature was assessed. Poor outcome was defined as persistent morbidity or fetal or neonatal death. Twenty-two cases of ADV were identified: nine retrospectively and 13 prospectively. Aberrant shunts from the umbilical vein were identified to the right atrium, coronary sinus, inferior vena cava (IVC) and iliac vein. In seven of 22 cases (32%) a wide connection was observed. In six of these seven cases (86%) the outcome was poor, including four with severe associated anomalies and two with hepatic dysfunction. In five of these cases, cardiomegaly with tricuspid regurgitation was observed, as well as underdevelopment of the portal system. In only five of 15 cases with a narrow shunt (33%) was the outcome poor, and in all five cases the poor outcome was related to associated anomalies. In cases of ADV with extrahepatic shunt, portal system development is impacted by the diameter of the shunt. If the shunt is narrow, the portal system will have developed normally. A wide shunt is associated with underdevelopment or absence of the portal system. In cases of ADV with extrahepatic shunt, prognosis is determined by the severity of associated anomalies, the diameter of the shunt and development of the portal system. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.
Common iliac vein stenosis and risk of symptomatic pulmonary embolism: an inverse correlation.
Chan, Keith T; Popat, Rita A; Sze, Daniel Y; Kuo, William T; Kothary, Nishita; Louie, John D; Hovsepian, David M; Hwang, Gloria L; Hofmann, Lawrence V
2011-02-01
To test the hypothesis that a common iliac vein (CIV) stenosis may impair embolization of a large deep venous thrombosis (DVT) to the lungs, decreasing the incidence of a symptomatic pulmonary embolism (PE). Between January 2002 and August 2007, 75 patients diagnosed with unilateral DVT were included in a single-institution case-control study. Minimum CIV diameters were measured 1 cm below the inferior vena cava (IVC) bifurcation on computed tomography (CT) images. A significant stenosis in the CIV ipsilateral to the DVT was defined as having either a diameter 4 mm or less or a greater than 70% reduction in lumen diameter. A symptomatic PE was defined as having symptoms and imaging findings consistent with a PE. The odds of symptomatic PE versus CIV stenosis were assessed using logistic regression models. The associations between thrombus location, stenosis, and symptomatic PE were assessed using a stratified analysis. Of 75 subjects, 49 (65%) presented with symptomatic PE. There were 17 (23%) subjects with a venous lumen 4 mm or less and 12 (16%) subjects with a greater than 70% stenosis. CIV stenosis of 4 mm or less resulted in a decreased odds of a symptomatic PE compared with a lumen greater than 4 mm (odds ratio [OR] 0.17, P = .011), whereas a greater than 70% stenosis increased the odds of DVT involving the CIV (OR 7.1, P = .047). Among patients with unilateral DVT, those with an ipsilateral CIV lumen of 4 mm or less have an 83% lower risk of developing symptomatic PE compared with patients with a CIV lumen greater than 4 mm. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Ding, Xue-Yan; Chen, Feng; Zhao, Xian-Xian; Wu, Hong; Chen, Shao-Ping; Qin, Yong-Wen
2011-01-01
A 19-year-old male patient presented cyanosis and dyspnoea because of the presence of multiple pulmonary arteriovenous fistulas resulting in oxygen desaturation. The CTA revealed that intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. This is the first reported case of hepatopulmonary syndrome caused by congenital extrahepatic portosystemic shunt in which intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. PMID:22937464
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taneja, Manish; Lath, Narayan, E-mail: lath_narayan@yahoo.com; Soo, Tan Bien
Fistulous communication between the renal artery stump and inferior vena cava following nephrectomy is rare. We describe the case of a 52-year-old man with a fistula detected on investigation for hemolytic anemia in the postoperative period. The patient had had a nephrectomy performed 2 weeks prior to presentation for blunt abdominal trauma. The fistula was successfully occluded percutaneously using an Amplatzer vascular plug. The patient recovered completely and was discharged 2 weeks later.
1987-10-01
demonstrated that endotoxin shock is associated with a decrease in compliance of the superior and inferior vena cavae and probably £ Abstracts 17 central...site of a burn wound. METHODS: Anesthetized 350 gram male Long Evans rats were prepared by intrarenal inferior vena cava (IVC) ligation. The rats...elastase has been investigated in the superior vena caval and left atrium blood collected from 167 patients who underwent open heart surgery. The effect
1988-01-01
were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutta, Usha; Garg, Pramod K.; Agarwal, Rajeev
1999-11-15
A 31-year-old man presented with idiopathic membranous obstruction of the suprahepatic inferior vena cava (IVC) and was treated by balloon dilation and placement of a Wallstent. The patient improved markedly. However, he developed obstruction of the hepatic vein outflow secondary to neointima formation over the stent that covered the hepatic vein ostia. The patient died of liver failure and septicemia. We believe that this is the first report of such a serious complication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali
Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.
Nanbu, Patricia Naomi; Hosoe, Takahiro; Hamai, Yuko; Shigematsu, Akiyo
2007-01-01
A marked difference in the healing process of the inferior vena cava in rats following a stab with a 17-G (1.48 mm phi) ultrahard zirconium ceramic (Zr) needle and with a common stainless steel (St) needle (also 1.48 mm phi was observed. This was investigated in vivo by histological imaging and biochemical micro-autoradiographic imaging using [2-(14)C]-thymidine as a biomarker in vivo. On the first day after the stab with either, the Zr or the St injection needle, the tunica adventitia showed the most pronounced damage, as evidenced by a large puncture wound characterized by blood congestion, but with few inflammatory cells being observed. A marked contraction of the tunica media was observed. The depth of the injury reached the tunica layer, but amounted to less than 1/3 of the needle diameter. Loose fragments of the endothelial lining were detected, together with scattered red corpuscles. The survival rate of the experimental animals amounted to less than 40% on the 3rd day after the stab by either the Zr or St needle, due to the large needle diameter. In addition, histological imaging of the wound area in the endothelial layer and tunica media showed considerable congestion and inflammation, which limited the evaluation of the regeneration status of the inferior vena cava of the surviving animals. Results were obtained from a few animals that displayed satisfactory recovery status. On the 3rd day after the stab by either the Zr or St injection needle, a relatively large proportion of the hemostatic clots became incorporated into the collagenous tissue, i.e. the tunica adventitia. A marked contraction of the tunica media was also observed, similar to that on the 1st day, following the needle injury. In the case of the endothelium (tunica intima), the injury caused by the Zr needle was reinfiltrated by adult stem cells 3 days after the stab, but the tunica media, composed of endothelial cells, still contained relatively contracted collagenous material. In addition, several interesting cell colonies were observed in the medial layer at the short distance from the boundary of the damaged tissue. It was assumed that these colonies produced medial tissue composed of collagenous supporting tissue or smooth muscle cells. In the experiment using the St needle, the incorporation of [2-(14)C]-thymidine into the nucleus of the stem cells was observed in the small capillaries of the tunica media, but not in the support cells of the latter.
Neonatal venous cerebral hemorrhage. Report of two cases.
Misra, Sanjay N; Misra, Ashish K
2003-10-15
Intracranial pathological changes can occur as a result of impaired craniocervical venous return. Thrombosis of central venous access catheters was demonstrated in two neonates born at 38 and 27 weeks' gestation. Neither infant developed hemorrhage of prematurity as confirmed on cranial ultrasonography. Clinical evidence of vena cava thrombosis and associated spontaneous intraventricular hemorrhage developed on Day 24 and 36, respectively, and these findings were confirmed on imaging studies. In one infant the hemorrhage was accompanied by communicating hydrocephalus. The cause of the intracranial disease was attributable to the retrograde cerebral venous congestion. This, together with the primitive venous bed developing in the periventricular region, was associated with the spontaneous hemorrhage in the region of the foramen of Monro. To the authors' knowledge, this is the first report in the English-language literature of spontaneous neonatal intracerebral hemorrhage, due to thrombosis of the superior or inferior vena cava. The natural history of this condition is resolution without sequelae after appropriate therapeutic intervention for the vena cava thrombosis.
Eo, Hyeyoon; Jeon, You-jin; Lee, Myoungsook; Lim, Yunsook
2015-01-14
Obesity is considered to be a metaflammatory condition. Ecklonia cava, brown algae rich in polyphenols, has shown strong antioxidant activity in vitro. This study investigated the effect of E. cava polyphenol extract (ECPE) on the regulation of fat metabolism, inflammation, and the antioxidant defense system in high fat diet-induced obese mice. After obesity was induced by a high-fat diet (HFD), the mice were administered ECPE by gavage for 5 days/12 weeks. ECPE supplementation reduced body weight gain, adipose tissue mass, plasma lipid profiles, hepatic fat deposition, insulin resistance, and the plasma leptin/adiponectin ratio derived from HFD-induced obesity. Moreover, ECPE supplementation selectively ameliorated hepatic protein levels associated with lipogenesis, inflammation, and the antioxidant defense system as well as activation of AMPK and SIRT1. Collectively, ECPE supplement might have potential antiobesity effects via regulation of AMPK and SIRT1 in HFD-induced obesity.
Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave
2015-11-04
We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.
Kang, Jieun; Kim, Seon Ok; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2018-05-17
Malignancy is associated with an increased risk of venous thromboembolism. Inferior vena cava filters are a viable alternative when anticoagulation is infeasible because of the risk of bleeding. Although the current guidelines recommend that all patients with a vena cava filter be treated with anticoagulation treatment when the risk of bleeding is reduced, studies concerning the role of concomitant anticoagulation after vena cava filter insertion in high-risk patients are scarce. Since many cancer patients suffer from a high risk of hemorrhagic complications, we aimed to determine the effect of post-filter anticoagulation on mortality in patients with a malignant solid tumor. A retrospective cohort study of patients with pulmonary embolism was performed between January 2010 and May 2016. Patients with a solid tumor and vena cava filter inserted because of pulmonary embolism were included. Using Cox proportional hazards model, the prognostic effect of clinical variables was analyzed. A total of 180 patients were analyzed, with 143 patients receiving and 37 patients not receiving post-filter anticoagulation treatment. Mortality was not significantly different between the two groups. The presence of metastatic cancer and that of pancreatobiliary cancer were significant risk factors for mortality. However, post-filter anticoagulation did not show significant effect on mortality regardless of the stage of cancer. In patients with cancer-associated pulmonary embolism, the effect of post-filter anticoagulation on mortality may not be critical, especially in patients with a short life expectancy.
Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solar, Miroslav; Ceral, Jiri, E-mail: ceral.jiri@fnhk.c; Krajina, Antonin
Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutivemore » patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.« less
Yu, C; Liu, Y; Zhu, X; Li, Y; Li, Y
2000-03-01
To compare the hemodynamic effect and energy loss of atrio-ventricular and total cavo-pulmonary connections versus atrio-pulmonary anastomosis for modified Fontan in dogs. Fifteen adult mongrel dogs were divided into three groups. Group I underwent right atrium to right ventricle (using 50% and 25% right ventricular chamber, respectively) connection with the flap of valved homo-pulmonary artery (modified Bjoerk procedure). Group II underwent total cavo-pulmonary connection. Group III received atrio-pulmonary anastomosis. Right atrium pressure, pulmonary artery pressure, and cardiac output were measured by Swan-Ganz catheter. The volumes of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured by electromagnetic flowmeter. The flow-rate of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured echocardiographically. The fluid energy loss was calculated. The postoperative right atrium pressure in group I was lower than in group III (P < 0.05). The postoperative stroke index in group I and group II was higher than in group III (P < 0.01). The fluid energy loss was decreased when 50% or 25% right ventricle chamber was used (P < 0.01) and the fluid energy less in group II was less than in group III. Our experience suggested that atrio-ventricular connection and total cavo-pulmonary connection would be better than atrio-pulmonary anastomosis for modified Fontan repair of tricuspid valve atresia.
Functional roles of cell surface peptidases in reproductive organs
2004-01-01
A number of biologically active peptides have been proposed to regulate function and differentiation of reproductive organs in an autocrine and/or paracrine fashion. Regulation of the local concentrations of these peptides is one of the important factors influencing their physiological effects on target cells. Membrane‐bound cell surface peptidases can activate or inactivate biologically active peptides before peptide factors access their receptors on the cell surface. Aminopeptidase A (EC 3.4.11.7), placental leucine aminopeptidase (EC 3.4.11.3), aminopeptidase‐N/CD13 (EC 3.4.11.2), dipeptidyl peptidases IV/CD26 (EC.3.4.14.5), carboxypeptidase‐M (EC 3.4.17.12), neutral endopeptidase/CD10 (EC 3.4.24.11) and endothelin converting enzyme‐1 (EC 3.4.23) are differentially expressed on the ovary, endometrium and placenta. The inhibition of enzyme activity affects steroid hormone production by granulosa and thecal cells, decidualization of endometrium and migration of extravillous trophoblasts. These findings suggest that membrane‐bound cell surface peptidases are local regulators for cellular growth and differentiation in reproductive organs by controlling extracellular concentration of peptide factors. (Reprod Med Biol 2004; 3: 165 –176) PMID:29662383
Yuki, Hideo; Kamai, Takao; Kubota, Keiichi; Abe, Hideyuki; Nishihara, Daisaku; Mizuno, Tomoya; Masuda, Akinori; Betsunoh, Hironori; Yashi, Masahiro; Fukabori, Yoshitatsu; Yoshida, Ken-Ichiro
2014-01-01
Background Renal cell carcinoma (RCC) with sarcomatoid differentiation is invasive, refractory to treatment, and has a higher mortality. Therefore, systemic therapy is still challenging, and the curative resection of localized or locally advanced RCC with sarcomatoid differentiation is very important. Axitinib is a potent and selective second-generation vascular endothelial growth factor receptor tyrosine kinase inhibitor with improved safety and tolerability. Axitinib is generally recommended as second-line therapy for advanced RCC because the phase III axitinib versus sorafenib in advanced RCC (AXIS) trial demonstrated that it achieved longer progression-free survival than sorafenib in patients with metastatic RCC after failure of an approved first-line regimen. Methods We present a 73-year-old man who had a large (13 cm in diameter) right RCC with sarcomatoid differentiation that directly invaded the duodenum and inferior vena cava. The patient presented with gastrointestinal bleeding, was unable to eat solid food, and had become emaciated. Thus, his classification was poor risk with anemia, hypercalcemia, and poor performance status, according to the Memorial Sloan-Kettering Cancer Center criteria. He seemed unlikely to survive if radical nephrectomy, cavotomy with thrombectomy, and pancreatoduodenectomy were performed. To reduce the tumor burden and potential operative complications, we administered axitinib as first-line neoadjuvant therapy. Results Six weeks of treatment reduced the tumor burden without causing severe toxicities. Subsequently, radical right nephrectomy, cavotomy with thrombectomy, and pancreatoduodenectomy were performed successfully. The pathological treatment effect of axitinib was grade 2 (two-thirds necrosis). The resected tumor showed a heterogeneous reaction for phosphorylated Akt (Ser-473) by Western blotting and immunohistochemistry, indicating that parts of the tumor were sensitive to axitinib and other parts were not. Conclusion Axitinib might be promising as preoperative or neoadjuvant therapy for locally advanced RCC (>cT3b or >cTanyN1). PMID:24627641
Bridging the gap: Hybrid cardiac echo in the critically ill.
Glaser, Jacob J; Cardarelli, Cassandra; Galvagno, Samuel; Scalea, Thomas M; Murthi, Sarah B
2016-11-01
Point-of-care ultrasound often includes cardiac ultrasound. It is commonly used to evaluate cardiac function in critically ill patients but lacks the specific quantitative anatomic assessment afforded by standard transthoracic echocardiography (TTE). We developed the Focused Rapid Echocardiographic Examination (FREE), a hybrid between a cardiac ultrasound and TTE that places an emphasis on cardiac function rather than anatomy. We hypothesized that data obtained from FREE correlate well with TTE while providing actionable information for clinical decision making. FREE examinations evaluating cardiac function (left ventricular ejection fraction), diastolic dysfunction (including early mitral Doppler flow [E] and early mitral tissue Doppler [E']), right ventricular function, cardiac output, preload (left ventricular internal dimension end diastole), stroke volume, stroke volume variation, inferior vena cava diameter, and inferior vena cava collapse were performed. Patients who underwent both a TTE and FREE on the same day were identified as the cohort, and quantitative measurements were compared. Correlation analyses were performed to assess levels of agreement. A total of 462 FREE examinations were performed, in which 69 patients had both a FREE and TTE. FREE ejection fraction was strongly correlated with TTE (r = 0.89, 95% confidence interval). Left ventricular outflow tract, left ventricular internal dimension end diastole, E, and lateral E' derived from FREE were also strongly correlated with TTE measurements (r = 0.83, r = 0.94, r = 0.77, and r = 0.88, respectively). In 82% of the patients, right ventricular function for FREE was the same as that reported for TTE; pericardial effusion was detected on both examinations in 94% of the cases. No significant valvular anatomy was missed with the FREE examination. Functionally rather than anatomically based hybrid ultrasound examinations, like the FREE, facilitate decision making for critically ill patients. The FREE's functional assessment correlates well with TTE measurements and may be of significant clinical value in critically ill patients, especially when used in remote operating environments where resources are limited. Diagnostic test, level III.
In vitro evaluation of clot capture efficiency of an absorbable vena cava filter.
Dria, Stephen J; Eggers, Mitchell D
2016-10-01
The purpose of this study was to determine the in vitro clot capture efficiency (CCE) of an investigational absorbable inferior vena cava filter (IVCF) vs the Greenfield IVCF. Investigational absorbable and Greenfield filters were challenged with polyacrylamide clot surrogates ranging from 3 × 5 to 10 × 24 mm (diameter × length) in a flow loop simulating the venous system. Filters were challenged with clots until CCE standard error of 5% or less was achieved under binomial statistics. Pressure gradients across the filters were measured for the largest size clot, enabling calculation of forces on the filter. The in vitro CCE of the absorbable IVCF was statistically similar to that of the Greenfield filter for all clot sizes apart from the 3 × 10-mm clot, for which there was statistically significant difference between filter CCEs (absorbable filter, 59%; Greenfield filter, 31%; P = .0001). CCE ranged from an average 32% for the 3 × 5-mm clot to 100% for 7 × 10-mm and larger clots for the absorbable IVCF. Pressure gradient across the absorbable filter with 10 × 24-mm clot averaged 0.14 mm Hg, corresponding to a net force on the filter of 2.1 × 10(-3) N, compared with 0.39 mm Hg or 5.8 × 10(-3) N (P < .001) for the Greenfield filter. CCE of the absorbable filter was statistically similar to or an improvement on that of the Greenfield stainless steel filter for all clot sizes tested. CCE of the Greenfield filter in this study aligned with data from previous studies. Given the efficacy of the Greenfield filter in attenuating the risk of pulmonary embolism, the current study suggests that the absorbable filter may be a viable candidate for subsequent human testing. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-03-16
A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.
Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-01-01
Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679
Retrievable Inferior Vena Cava Filters for Venous Thromboembolism
Win, Lei Lei
2013-01-01
Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.
Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.
Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp
A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.
Needle versus Tube Thoracostomy in a Swine Model of Traumatic Tension Hemopneumothorax
2009-03-01
jugular vein, through the right atrium , and into the inferior vena cava . Serial digital C-arm chest x-rays allowed mea- surement of the shift from midline...wire in the inferior vena cava 1.34 cm to the right of the spinous processes. B: Insufflation resulted in a mediastinal shift of 2.15 cm to the left of...Received April 26, 2008, from the U.S. Army Institute of Surgical Re- search (JBH, JGM), Fort Sam Houston, Texas; the Naval Medical Cen- ter (STK), San Diego
A Novel Technique for Inferior Vena Cava Filter Extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn
Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.
Agematsu, Kouta; Naito, Yuji; Aoki, Mitsuru; Fujiwara, Tadashi
2008-04-01
The presented case was a 3-year-old boy diagnosed with asplenia (SLL), double outlet right ventricle, pulmonary stenosis, atrioventricular septal defect, hypoplastic left ventricle and partial anomalous pulmonary venous connection to the superior vena cava. Partial anomalous pulmonary venous connection was repaired by translocation of pulmonary artery to avoid pulmonary venous obstruction when Glenn anastomosis was performed. Total cavo-pulmonary connection was established by re-routing the inferior vena cava to pulmonary artery using the atrial septal remnant and the left atrium free wall flap.
Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele
2017-02-01
Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.
Sanders, Barbara P.; de los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G.; Song, Yutong; Cooper, Gillian; Crawt, Laura E.; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H. H. V.; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana
2016-01-01
The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4–9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV. PMID:27032093
Mechanical support of total cavopulmonary connection with an axial flow pump.
Riemer, R Kirk; Amir, Gabriel; Reichenbach, Steven H; Reinhartz, Olaf
2005-08-01
Even under optimal circumstances, total cavopulmonary connection is associated with a continuous late risk of death. Hemodynamics are distinctly abnormal, with increased systemic venous pressures and frequent low cardiac output. Our study uses a sheep model of total cavopulmonary connection to test the response to axial flow pump (Thoratec HeartMate II; Thoratec Corporation (Pleasanton, Calif)) support of total cavopulmonary connection, which might be suitable to treat patients with failing Fontan circulation. Eight sheep (42-48 kg) were studied. After pilot studies in 3 animals, 5 underwent both pump-supported and nonsupported total cavopulmonary connection in alternating sequence for up to 2 hours. This was achieved with a 12-mm polytetrafluoroethylene graft from the (distally ligated) superior vena cava to the main pulmonary artery and a cannula placed in the inferior vena cava with an attached 16-mm Dacron graft to the main pulmonary artery. Pressures (arterial, inferior vena cava, left atrium, and pulmonary artery) and flows (ascending aorta and inferior vena cava) were recorded over 1 hour both with unsupported total cavopulmonary connection and after placing an axial flow pump (Thoratec HeartMate II) between the inferior vena caval inflow cannula and the main pulmonary artery. Under nonsupported total cavopulmonary connection circulation, inferior vena caval and aortic blood flow decreased by nearly 50%. Inferior vena caval pressure nearly doubled, whereas arterial pressure decreased by one third. Pulmonary artery pressure became nonpulsatile; however, mean pulmonary artery pressure and left atrial pressure did not change significantly. With pump-supported Fontan circulation, cardiac output, inferior vena caval flow, and arterial pressure returned to baseline. Inferior vena caval pressure decreased to below baseline levels. Mean pulmonary artery pressure and left atrial pressure again remained unchanged. Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.
Sanders, Barbara P; de Los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G; Song, Yutong; Cooper, Gillian; Crawt, Laura E; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H H V; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana
2016-03-01
The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4-9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV.
Kalicki, Boleslaw; Sadecka, Monika; Wawrzyniak, Agata; Kozinski, Piotr; Dziekiewicz, Miroslaw; Jung, Anna
2015-04-14
Absence of the inferior vena cava is a rare vascular anomaly, which usually remains asymptomatic in childhood. It is recognized as the risk factor for deep venous thrombosis, since the collateral circulation does not provide adequate drainage of the lower limbs. Mycoplasma pneumoniae is a common cause of community-acquired pneumonia in school-aged children and adolescents. Mycoplasma pneumoniae infection might be associated with deep venous thrombosis but its pathophysiology remains unknown. According to previous reports, deep venous thrombosis due to Mycoplasma pneumoniae infection is associated with positive serum anticardiolipin antibodies. To our knowledge, we describe the first case of deep venous thrombosis associated with Mycoplasma pneumoniae serum antibodies indicating early stage of infection with negative anticardiolipin serum antibodies in adolescent with absence of inferior vena cava. 14-year old boy was admitted to the pediatric unit few days after the appendectomy complaining with pain of the left hip that caused him unable to walk. The pain was accompanied with subfebrile temperature. After clinical examination and additional tests, the boy was diagnosed with a deep venous thrombosis. Computed tomography revealed absence of the vena cava inferior distally to the hepatic veins and varices of the collateral circulation in the pelvis. Anticardiolipin IgM and IgG antibodies and antinuclear antibodies were not detected. Additionally, the Mycoplasma pneumoniae antibodies in classes IgM, IgA and IgG were detected in serum as another risk factor of thrombosis. After the initial treatment with low-molecular-weight heparin in combination with clarithromycin the clinical condition of the patient improved. The patient became a candidate for life-long anticoagulation therapy. In this case Mycoplasma pneumoniae antibodies were associated with deep venous thrombosis in child with congenital absence of inferior vena cava. Uncommonly for deep venous thrombosis due to Mycoplasma pneumoniae infection, anticardiolipin antibodies were not detected in serum. It is important to remember in clinical practice that Mycoplasma pneumoniae affects coagulability and may trigger thrombosis, especially in the presence of other risk factors. The pathophysiology of this process remains unknown.
Lee, WonWoo; Oh, Jae Young; Kim, Eun-A; Kang, Nalae; Kim, Kil-Nam; Ahn, Ginnae; Jeon, You-Jin
2016-07-01
In this study, the beneficial prebiotic roles of Ecklonia cava (E. cava, EC) were evaluated on the growth of lactic acid bacteria (LAB) and pathogen bacteria and the mortality of pathogen-bacteria infected zebrafish model. The result showed that the original E. cava (EC) led to the highest growth effects on three LABs (Lactobacillus brevis, L. brevis; Lactobacillus pentosus, L. pentosus; Lactobacillus plantarum; L. plantarum) and it was dose-dependent manners. Also, EC, its Celluclast enzymatic (ECC) and 100% ethanol extracts (ECE) showed the anti-bacterial activities on the fish pathogenic bacteria such as (Edwardsiella tarda; E. tarda, Streptococcus iniae; S. iniae, and Vibrio harveyi; V. harveyi). Interestingly, EC induced the higher production of the secondary metabolites from L. plantarum in MRS medium. The secondary metabolites produced by EC significantly inhibited the growth of pathogen bacteria. In further in vivo study, the co-treatment of EC and L. plantarum improved the growth and mortality of E. tarda-infected zebrafish as regulating the expression of inflammatory molecules such as iNOS and COX2. Taken together, our present study suggests that the EC plays an important role as a potential prebiotic and has a protective effect against the infection caused by E. tarda injection in zebrafish. Also, our conclusion from this evidence is that EC can be used and applied as a useful prebiotic. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pak, Kyoungjune; Kim, Keunyoung; Kim, Mi-Hyun; Eom, Jung Seop; Lee, Min Ki; Cho, Jeong Su; Kim, Yun Seong; Kim, Bum Soo; Kim, Seong Jang; Kim, In Joo
2018-01-01
We aimed to develop a decision tree model to improve diagnostic performance of positron emission tomography/computed tomography (PET/CT) to detect metastatic lymph nodes (LN) in non-small cell lung cancer (NSCLC). 115 patients with NSCLC were included in this study. The training dataset included 66 patients. A decision tree model was developed with 9 variables, and validated with 49 patients: short and long diameters of LNs, ratio of short and long diameters, maximum standardized uptake value (SUVmax) of LN, mean hounsfield unit, ratio of LN SUVmax and ascending aorta SUVmax (LN/AA), and ratio of LN SUVmax and superior vena cava SUVmax. A total of 301 LNs of 115 patients were evaluated in this study. Nodular calcification was applied as the initial imaging parameter, and LN SUVmax (≥3.95) was assessed as the second. LN/AA (≥2.92) was required to high LN SUVmax. Sensitivity was 50% for training dataset, and 40% for validation dataset. However, specificity was 99.28% for training dataset, and 96.23% for validation dataset. In conclusion, we have developed a new decision tree model for interpreting mediastinal LNs. All LNs with nodular calcification were benign, and LNs with high LN SUVmax and high LN/AA were metastatic Further studies are needed to incorporate subjective parameters and pathologic evaluations into a decision tree model to improve the test performance of PET/CT.
Ochiai, Toshiya; Komiyama, Sosuke; Ikoma, Hisashi; Kubota, Takeshi; Nakanishi, Masayoshi; Ichikawa, Daisuke; Kikuchi, Shojiro; Fujiwara, Hitoshi; Sakakura, Chohei; Kokuba, Yukihito; Sonoyama, Teruhisa; Otsuji, Eigo
2010-08-01
Poorly differentiated neuroendocrine carcinoma has a poor prognosis, especially when associated with distant metastasis. A 60-year-old man was admitted to a private hospital because of dyspnea at work in 2007. Computed tomography revealed lung infarction and a right adrenal tumor sized 12 cm in diameter that was tightly compressed against the inferior vena cava (IVC). Moreover, multiple lymph node metastases around the celiac axis and a solitary liver metastasis at the lateral segment were observed. Thus, we planned chemotherapy without surgery. We selected a combination therapy of irinotecan (CPT-11) and cisplatin (CDDP) (i.e., IP therapy): administration of CDDP [60 mg/m(2) body surface area (BSA)] on day 1 plus CPT-11 (80 mg/m(2)) BSA on days 1 and 8. Thereafter, this protocol was repeated at 3-week intervals. After 15 months of this chemotherapy strategy, the whole lesions showed a partial response by RECIST. The primary tumor had shrunk to 4.2 cm in diameter. In November 2008, we planned surgery to perform resection of the whole lesions. Histological diagnosis of the specimen was a poorly differentiated neuroendocrine carcinoma based on the immunostaining features, i.e., synaptophysin- and chromogranin positive. There were no viable tumor cells at the dissected lymph nodes or at the liver tumor. After surgery, CPT-11 administration was continued. The patient has remained well for 9 months without recurrence.
NASA Astrophysics Data System (ADS)
Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin
2012-11-01
The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.
Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com
Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less
Duffett, L; Carrier, M
2017-01-01
Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.
Strategies for the Management of SVC Stent Migration into the Right Atrium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, J. D., E-mail: drjeremytaylor@yahoo.co.uk; Lehmann, E. D.; Belli, A.-M.
Purpose. Stent migration into the right atrium is a potentially fatal complication of stenting in the venous system and is most likely to occur during the treatment of superior vena cava obstruction. Endovascular approaches that can salvage this hazardous situation are described and the keys to successful treatment are highlighted. Materials and Methods. Four different strategies are reviewed: (1) snaring the stent directly, (2) angioplasty balloon-assisted snaring of the stent, (3) guide wire-assisted snaring of the stent, and (4) superior vena cava-to-inferior vena cava bridging stent. Results. These techniques have been employed in the successful management of four cases. Nomore » short- or long-term complications as a result of these maneuvers have been identified. Additional treatment of the underlying disease was possible at the same time in each case. Conclusion. We conclude that prompt management of right atrial stent migration is essential and can be successfully achieved by a variety of 'bale-out' techniques which are within the technical range of most interventional radiologists.« less
Calcified inferior vena cava and right atrial myxoma in an 18-month-old male: A case report.
Chen, Renwei; Deng, Xicheng; Luo, Jinwen; Huang, Peng
2018-06-01
Cardiac myxomas are the most frequent primary cardiac tumor in adults. The incidence in pediatric patients is extremely low. Heavy calcification of an atrial myxoma is uncommon in children. An 18-month-old boy was admitted for a significant precordial systolic murmur. Transthoracic echocardiography revealed a cardiac mass extending from the inferior vena cava across the right atrium and tricuspid valve into the right ventricle with severe tricuspid regurgitation. According to the echocardiography result, the patient was diagnosed with an inferior vena cava and right atrial tumor with tricuspid regurgitation. After the diagnosis, the patient underwent removal of the tumor via median sternotomy. The mass was removed under cardiopulmonary bypass with deep hypothermia circulatory arrest. The tricuspid valve was repaired by valvuloplasty and annuloplasty. The postoperative recovery was unremarkable. Follow-up echocardiogram at 1 month revealed moderate tricuspid regurgitation without myxoma recurrence. Heavy calcification of an atrial myxoma is uncommon especially in children. Definitive therapy for myxomas requires prompt surgical excision and long-term follow-up is recommended in children although recurrence after excision is rare.
Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz
2010-08-01
A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.
Superior Vena Cava Stent Migration into the Pulmonary Artery Causing Fatal Pulmonary Infarction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, Girija, E-mail: gijanandm@hotmail.com; Lewanski, Conrad R.; Cowman, Steven A.
2011-02-15
Migration of superior vena cava (SVC) stents is a well-recognised complication of their deployment, and numerous strategies exist for their retrieval. To our knowledge, only three cases of migration of an SVC stent to the pulmonary vasculature have previously been reported. None of these patients developed complications that resulted in death. We report a case of SVC stent migration to the pulmonary vasculature with delayed pulmonary artery thrombosis and death from pulmonary infarction. We conclude that early retrieval of migrated stents should be performed to decrease the risk of serious complications.
Extreme premature with persistent left superior vena cava.
Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin
2017-10-01
Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.
Jacobi, C A; Junghans, T; Peter, F; Naundorf, D; Ordemann, J; Müller, J M
2000-11-01
Injury of venous vessels during elevated intraperitoneal pressure is thought to cause possible fatal gas embolism, and helium may be dangerous because of its low solubility. Twenty pigs underwent laparoscopy with either CO2 (n=10) or helium (n=10) with a pressure of 15 mm Hg and standardized laceration (1 cm) of the vena cava inferior. After 30 s, the vena cava was clamped, closed endoscopically by a running suture and unclamped again. During the procedure changes of cardiac output (CO), heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), pulmonary artery pressure (PAP), pulmonary artery wedge pressure (PAWP), end tidal CO2 pressure (PETCO2), and arterial blood gas analyses (pH, pO2 and pCO2) were investigated. No animal died during the experimental course (mean blood loss during laceration: CO2, 157+/-50 ml; helium, 173+/-83 ml). MAP and CO values showed a decrease after laceration of the vena cava in both groups that had already been completely compensated for before suturing. PETCO2 increased significantly after CO2 insufflation (P<0.01), while helium showed no effect. Laceration of the vena cava caused no significant changes in PETCO2 values in either group. Significant acidosis and an increase of pCO2 were only found in the CO2 group. The incidence of gas embolism during laparoscopy and accidental vessel injury seems to be very low. With the exception of acidosis and an increase of PETCO2 in the CO2 group, there were no differences in cardiopulmonary function between insufflation of CO2 and helium.
Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin
2014-01-01
Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418
NASA Astrophysics Data System (ADS)
Alonso-Henar, Jorge; Alvarez-Gomez, José Antonio; Jesús Martinez-Diaz, José
2017-04-01
The Central American Volcanic Arc (CAVA) is located at the western margin of the Caribbean plate, over the Chortís Block, spanning from Guatemala to Costa Rica. The CAVA is associated to the subduction of the Cocos plate under the Caribbean plate at the Middle America Trench. Our study is focused in the Salvadorian CAVA segment, which is tectonically characterized by the presence of the El Salvador Fault Zone (ESFZ), part of the western boundary of a major block forming the Caribbean plate (the Chortis Block). The structural evolution of the western boundary of the Chortis Block, particularly in the CAVA crossing El Salvador remains unknown. We have done a kinematic analysis from seismic and fault slip data and combined our results with a review of regional previous studies. This approach allowed us to constrain the tectonic evolution and the forces that control the deformation in northern Central America. Along the active volcanic arc we identified active transtensional deformation. On the other hand, we have identified two deformation phases in the back arc region: A first one of transpressional wrenching close to simple shearing (Miocene); and a second one characterized by almost E-W extension. Our results reveal a change from transpressional to transtensional shearing coeval with a migration of the volcanism towards the trench in Late Miocene times. This strain change could be related with a coupled to decoupled transition on the Cocos - Caribbean subduction interface, which could be related to a slab roll-back of the Cocos Plate beneath the Chortis Block. The combination of different degrees of coupling on the subduction interface, together with a constant relative eastward drift of the Caribbean Plate, control the deformation style along the western boundary of the Chortis Block.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com; Akdogan, Meral, E-mail: akdmeral@yahoo.com; Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com
PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture andmore » traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.« less
Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma
2016-09-01
A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul
Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.
Perri, Gianluigi; Filippelli, Sergio; Kirk, Richard; Hasan, Asif; Griselli, Massimo
2012-05-01
Anomalies of the pulmonary venous drainage vary widely in their anatomic spectrum and clinical presentation. We describe an unusual case of supra-cardiac total anomalous pulmonary venous connection (TAPVC), where the pulmonary veins drained directly in the posterior aspect of proximal right superior vena cava (SVC) through separate ostia. The veins were re-routed with a patch to the left atrium via the secundum atrial septal defect (ASD). The continuity between distal SVC and right atrium was re-established by re-implanting the SVC to the right atrial appendage (Warden Procedure). © 2012 Wiley Periodicals, Inc.
Focal Atrial Tachycardia Arising from the Inferior Vena Cava
Lim, Yeong-Min; Uhm, Jae-Sun
2017-01-01
The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006
Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM
Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi
2017-01-01
Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027
Tashi, Sonam; Ng, Keng Sin
2015-01-01
Cushing’s syndrome is known to have a wide spectrum of clinical presentation with debilitating consequences and morbidity if not diagnosed and treated in time. Sometimes the diagnosis of Cushing’s syndrome can be challenging to the endocrinologist, especially when the usual battery of biochemical tests and advanced cross-sectional imaging is negative or inconclusive. We described a case in which the use of bilateral inferior petrosal sinus sampling (BIPSS) was conclusive albeit being technically challenging (due to a rare incidental finding of double superior vena cava) and invasive in nature. PMID:26629301
Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay
2015-04-01
Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.
Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications
DeYoung, Elliot; Minocha, Jeet
2016-01-01
Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472
Ko, Seok-Chun; Lee, Myoungsook; Lee, Ji-Hyeok; Lee, Seung-Hong; Lim, Yunsook; Jeon, You-Jin
2013-11-01
In this study, we assessed the potential inhibitory effect of 5 species of brown seaweeds on adipogenesis the differentiation of 3T3-L1 preadipocytes into mature adipocytes by measuring Oil-Red O staining. The Ecklonia cava extract tested herein evidenced profound adipogenesis inhibitory effect, compared to that exhibited by the other four brown seaweed extracts. Thus, E. cava was selected for isolation of active compounds and finally the three polyphenol compounds of phlorotannins were obtained and their inhibitory effect on adipogenesis was observed. Among the phlorotannins, dieckol exhibited greatest potential adipogenesis inhibition and down-regulated the expression of peroxisome proliferator-activated receptor-γ (PPARγ), CCAAT/enhancer-binding proteins (C/EBPα), sterol regulatory element-binding protein 1 (SREBP1) and fatty acid binding protein 4 (FABP4) in a dose-dependent manner. The specific mechanism mediating the effects of dieckol was confirmed by AMP-activated protein kinase (AMPK) activation. These results demonstrate inhibitory effect of dieckol compound on adipogenesis through the activation of the AMPK signal pathway. Copyright © 2013 Elsevier B.V. All rights reserved.
Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan
2017-12-01
The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.
Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.
White, R N; Parry, A T
2016-05-01
To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.
Zhu, Guanchen; Qiu, Xuefeng; Chen, Xianchen; Liu, Guangxiang; Zhang, Gutian; Gan, Weidong; Guo, Hongqian
2015-12-01
Renal cell carcinoma (RCC) accounts for 85-90% of kidney cancers, which in turn account for 2-3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7-10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC.
ZHU, GUANCHEN; QIU, XUEFENG; CHEN, XIANCHEN; LIU, GUANGXIANG; ZHANG, GUTIAN; GAN, WEIDONG; GUO, HONGQIAN
2015-01-01
Renal cell carcinoma (RCC) accounts for 85–90% of kidney cancers, which in turn account for 2–3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7–10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC. PMID:26788164
Inferior vena cava tumor thrombus after partial nephrectomy for renal cell carcinoma.
Akatsuka, Jun; Suzuki, Yasutomo; Hamasaki, Tsutomu; Shindo, Takao; Yanagi, Masato; Kimura, Go; Yamamoto, Yoichiro; Kondo, Yukihiro
2014-03-29
Partial nephrectomy is now the gold standard treatment for small renal tumors. Local recurrence is a major problem after partial nephrectomy, and local recurrence in the remnant kidney after partial nephrectomy is common. A 77-year-old man underwent right partial nephrectomy for a T1 right renal cell carcinoma. Microscopic examination revealed a clear cell renal carcinoma, grade 2, stage pT3a. Although the surgical margin was negative, the carcinoma invaded the perirenal fat, and vascular involvement was strongly positive. Thirty months after partial nephrectomy, an enhanced computed tomographic scan showed local recurrence of the renal cell carcinoma extending into the inferior vena cava without renal mass. Hence, we performed right radical nephrectomy and intracaval thrombectomy. Microscopic examination revealed a clear cell carcinoma grade 2, stage pT3a + b. The patient is still alive with no evidence of recurrence 10 months post-procedure. To our knowledge, local recurrence of renal cell carcinoma extending into the inferior vena cava after partial nephrectomy has not been reported in the literature. Our case report emphasizes the importance of strict surveillance of patients after partial nephrectomy, especially for those with renal cell carcinoma positive for microvessel involvement.
Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro
2008-10-01
A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.
Lauten, Alexander; Figulla, Hans R; Unbehaun, Axel; Fam, Neil; Schofer, Joachim; Doenst, Torsten; Hausleiter, Joerg; Franz, Marcus; Jung, Christian; Dreger, Henryk; Leistner, David; Alushi, Brunilda; Stundl, Anja; Landmesser, Ulf; Falk, Volkmar; Stangl, Karl; Laule, Michael
2018-02-01
Transcatheter caval valve implantation is under evaluation as a treatment option for inoperable patients with severe tricuspid regurgitation (TR). The procedure involves the catheter-based implantation of bioprosthetic valves in the inferior vena cava and superior vena cava to treat symptoms associated with TR. This study is the first to evaluate the feasibility, safety, and efficacy of this interventional concept. Twenty-five patients (mean age, 73.9±7.6 years; women, 52.0%) with severe symptomatic TR despite optimal medical treatment deemed unsuitable for surgery were treated with caval valve implantation under a compassionate clinical use program. Technical feasibility defined as procedural success, hemodynamic effect defined as venous pressure reduction, and safety defined as periprocedural adverse events were evaluated, with clinical follow-up at discharge and up to 12 months. The functional impact was evaluated by assessment of New York Heart Association class at the time of hospital discharge. The total number of valves implanted in the caval position was 31. Patients were treated with single (inferior vena cava-only; n=19; 76.0%) or bicaval valve implantation (inferior vena cava+superior vena cava; n=6; 24.0%). Either balloon-expandable valves (Sapien XT/3: n=18; 72.0%) or self-expandable valves (TricValve: n=6; 24.0%; Directflow: n=1; 4.0%) were used. Procedural success was achieved in 96% (n=24). Early and late valve migration requiring surgical intervention occurred in 1 patient each. Thirty-day and in-hospital mortality were 8% (2 of 25) and 16% (4 of 25). Causes of in-hospital mortality included respiratory (n=1) or multiple organ failure (n=3) and were not linked to the procedure. Mean overall survival in the study cohort was 316±453 days (14-1540 days). Caval valve implantation for the treatment of severe TR and advanced right ventricular failure is associated with a high procedural success rate and seems safe and feasible in an excessive-risk cohort. The study demonstrates hemodynamic efficacy with consistent elimination of TR-associated venous backflow and initial clinical improvement. These results encourage further trials to determine which patients benefit most from this interventional approach. © 2018 American Heart Association, Inc.
Large thoracic tumor without superior vena cava syndrome.
Garmpis, Nikolaos; Damaskos, Christos; Patelis, Nikolaos; Dimitroulis, Dimitrios; Spartalis, Eleftherios; Tomos, Ioannis; Garmpi, Anna; Spartalis, Michael; Antoniou, Efstathios A; Kontzoglou, Konstantinos; Tomos, Periklis
2017-04-10
A 62 year-old male with long-standing smoking history presented with hemoptysis. Plain chest x-ray showed abnormal findings proximate to the right pulmonary hilum. Bronchoscopy revealed a fragile exophytic tumor of the right wall of the lower third of the trachea, infiltrating the right main bronchus (75% stenosis) and the right upper lobar bronchus (near total occlusion). Contrast-enhanced chest CT demonstrated a 7.2x4.9 cm tumor contiguous to the above-mentioned structures, mediastinal lymph node pathology, and a vessel coursing inferiorly to the left of the aortic arch and anterior to the left hilum. Despite the tumor constricting the right superior vena cava, no signs of superior vena cava syndrome were present. In this case, the patient does not present with Superior Vena Cava (SVC) syndrome, as expected due to the constriction of the (right) SVC caused by the tumor, since head and neck veins drain through the Persistent Left Superior Vena Cava (PLSVC). PLSVC is the most common thoracic venous anomaly with an incidence of 0.3% to 0.5% of the general population and it is a congenital anomaly caused by the failure of the left anterior cardinal vein to regress and to consequently form the ligament of Marshall during fetal development. It is associated with absence of the left brachiocephalic vein and in 10 to 20% of cases the right SVC is absent. Two potential draining points of the PLSVC have been previously reported. In the majority of cases PLSVC drains directly into the coronary sinus, but less frequently it drains into the left atrium or the left superior pulmonary vein. In cases where the PLSVC drains into the coronary sinus, congenital heart defects are rare. The patient usually remains asymptomatic and PLSVC is an incidental finding during radiographic imaging or medical procedures. When the PLSVC drains into the left atrium or the left superior pulmonary vein, a right-to-left shunt is formed; a condition usually asymptomatic. In some reported cases this PLSVC variant presents with persistent, unexplained hypoxia or cyanosis and embolisation causing recurrent transient ischemic attacks and/or cerebral abscesses. This PLSVC variant is more often associated with absence of the right SVC and congenital heart abnormalities.
Primary Pulmonary Ewing's Sarcoma: Rare Cause of Superior Vena Cava Syndrome in Children.
Mehra, Shibani; Atwal, Swapndeep Singh; Garga, Umesh Chandra
2014-08-01
Ewing's sarcoma is a common malignant bone tumour presenting in children and young adults. Rarely extra- skeletal soft tissues and visceral organs can also be the site of origin of Ewing's sarcoma. Primary pulmonary Ewing's sarcoma is an extremely rare malignancy which occurs in the paediatric population. We report an unusual case of primary pulmonary Ewing's sarcoma in a nine year old girl who presented with features of superior vena cava syndrome in the emergency department. The diagnosis was confirmed pathologically both by light microscopy and immunohistochemistry. The patient was put on chemotherapy and surgery was planned but the patient expired within three days of starting chemotherapy.
Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra
2014-01-01
Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC. PMID:25506021
Acar, Turker; Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra
2014-01-01
Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erol, Ilknur; Cetin, I. Ilker; Alehan, Fuesun
A previously healthy 12-year-old girl presented with severe headache for 2 weeks. On physical examination, there was finger clubbing without apparent cyanosis. Neurological examination revealed only papiledema without focal neurologic signs. Cerebral magnetic resonance imaging showed the characteristic features of brain abscess in the left frontal lobe. Cardiologic workup to exclude a right-to-left shunt showed an abnormality of the systemic venous drainage: presence of isolated left superior vena cava draining into the left atrium in the absence of coronary sinus and atrial septal defect. This anomaly is rare, because only a few other cases have been reported.
Wu, Yuan; Xu, Shuangyue; Guo, Hongwei; Yan, Guoliang; Qi, Zhongquan; Shan, Zhonggui
2014-07-01
We report a case of a 44-year-old male patient with ectopic drainage from the inferior vena cava to the left atrium accompanied by partial anomalous pulmonary venous drainage. After the patient was hospitalized, his diagnosis was confirmed by Doppler echocardiography and angiography. A pericardial patch was used to divert the blood to the atrium. The surgical procedure was successful, and the patient began a rehabilitation program 8 days later. This type of ectopic drainage pattern is an unusual and infrequent clinical finding. The definitive diagnosis should be made by Doppler ultrasound combined with angiography. Copyright © 2014 Elsevier Inc. All rights reserved.
Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele
2018-03-01
The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-01-01
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wildberger, Joachim Ernst, E-mail: wildberg@rad.rwth-aachen.de; Haage, Patrick; Bovelander, Jan
2005-04-15
Purpose. To evaluate the size and quantity of downstream emboli after thrombectomy using the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with or without temporary filtration for extensive iliofemoral and iliocaval thrombi in an in vitro flow model. Methods. Iliocaval thrombi were simulated by clotted bovine blood in a flow model (semilucent silicone tubings, diameter 12-16 mm). Five experimental set-ups were performed 10 times each; thrombus particles and distribution were measured in the effluent. First, after retrograde insertion, mechanical thrombectomy was performed using the PTD alone. Then a modified self-expanding tulip-shaped temporary vena cava stent filter was inserted additionally at the beginningmore » of each declotting procedure and removed immediately after the intervention without any manipulation within or at the filter itself. In a third step, the filter was filled with thrombus only. Here, two experiments were performed: Careful closure within the flow circuit without any additional fragmentation procedure and running the PTD within the filter lumen, respectively. In the final set-up, mechanical thrombectomy was performed within the thrombus-filled tubing as well as in the filter lumen. The latter was closed at the end of the procedure and both devices were removed from the flow circuit. Results. Running the PTD in the flow circuit without filter protection led to a fragmentation of 67.9% ({+-}7.14%) of the clot into particles {<=}500 {mu}m; restoration of flow was established in all cases. Additional placement of the filter safely allowed maceration of 82.9% ({+-}5.59%) of the thrombus. Controlled closure of the thrombus-filled filter within the flow circuit without additional mechanical treatment broke up 75.2% ({+-}10.49%), while additional mechanical thrombectomy by running the PTD within the occluded filter led to dissolution of 90.4% ({+-}3.99%) of the initial clot. In the final set-up, an overall fragmentation rate of 99.6% ({+-}0.44%) was achieved. Conclusions. The combined use of the Arrow-Trerotola PTD and a temporary vena cava stent filter proved to be effective for even large clot removal in this experimental set-up.« less
Murthi, Sarah B; Fatima, Syeda; Menne, Ashely R; Glaser, Jacob J; Galvagno, Samuel M; Biederman, Stephen; Fang, Raymond; Chen, Hegang; Scalea, Thomas M
2017-03-01
The intended physiologic response to a fluid bolus is an increase in stroke volume (SV). Several ultrasound (US) measures have been shown to be predictive. The best measure(s) in critically ill surgical patients remains unclear. This is a prospective observational study in critically ill surgical patients receiving a bolus of crystalloid, colloid or blood. A transthoracic echocardiogram was performed before (pre-transthoracic echocardiogram) and after. A positive volume response (+VR) was defined as a ≥15% increase in SV. Predictive measures were: left ventricular velocity time integral (VTI), respiratory SV variation (rSVV), passive leg raise SVV (plr SVV), positional internal jugular (IJ) vein change (0-90 degrees) and respiratory variation in the IJ sitting upright (90 degrees IJ). For each measure the area under the receiver operating curve (AUROC) was assessed and the best measure(s) determined. Between November 2013 and November 2015, 199 patients completed the study. After the pilot analyses, plr SVV was abandoned because it could not be reliably assessed. VTI, rv 90 degrees IJ, 0 degree to 90 degrees IJ, were all significantly associated with VR (p < 0.05), rSVV and rv inferior vena cava were not. For VTI AUROC was 0.71 (95% confidence interval [CI], 0.64-0.77). For rv 90 degrees, it was 0.65 (95% CI, 0.57-0.71), and 0.61 (95% CI, 0.54-0.69) for 0 degrees to 90 degrees IJ. When VTI and rv 90 degrees were considered together, the AUROC rose to 0.76 (95% CI, 0.69-0.82) for the population as a whole and 0.78 (95% CI, 0.69-0.85) in mechanically ventilated patients. The positive predictive value for combined assessment was 80% and the negative 70%. In a clinically relevant heterogeneous population, US is moderately predictive of VR. Inferior vena cava diameter change is not predictive. IJ change and VTI are the best measures, especially when used together. Future work should focus on combination metrics and the IJ. Diagnostic test, level II.
Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahrer, Arie; Zippel, Douglas; Garniek, Alexander
The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavographymore » prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.« less
Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K
2016-12-01
The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.
Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli
NASA Technical Reports Server (NTRS)
Butler, B. D.; Morris, W. P.
1995-01-01
Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.
NASA Astrophysics Data System (ADS)
Schindlbeck, J. C.; Kutterolf, S.; Hemming, S. R.; Wang, K. L.
2015-12-01
Including the recently drilled CRISP sites (IODP Exp. 334&344) the deep sea drilling programs have produced 69 drill holes at 29 Sites during 9 Legs at the Central American convergent margin, where the Cocos plate subducts beneath the Caribbean plate. The CAVA produced numerous plinian eruptions in the past. Although abundant in the marine sediments, information and data regarding large late Cenozoic explosive eruptions from Costa Rica, Nicaragua, Honduras, El Salvador, and Guatemala remain very sparse and discontinuous on land. We have established a tephrostratigraphy from recent through Miocene times from the unique archive of ODP/IODP sites offshore Central America in which we identify tephra source regions by geochemical fingerprinting using major and trace element glass shard compositions. Here we present first order correlations of ~500 tephra layers between multiple holes at a single site as well as between multiple sites. We identified ashes supporting Costa Rican (~130), Nicaraguan (17) and Guatemalan (27) sources as well as ~150 tephra layers from the Galápagos hotspot. Within our marine record we also identified well-known marker beds such as the Los Chocoyos tephra from Atitlán Caldera in Guatemala and the Tiribi Tuff from Costa Rica but also correlations to 15 distinct deposits from known Costa Rican and Nicaraguan eruptions within the last 4.1 Ma. These correlations, together with new radiometric age dates, provide the base for an improved tephrochronostratigraphy in this region. Finally, the new marine record of explosive volcanism offshore southern CAVA provides insights into the eruptive history of long-living volcanic complexes (e.g., Barva, Costa Rica) and into the distribution and frequency of large explosive eruptions from the Galápagos hotspot. The integrated approach of Ar/Ar age dating, correlations with on land deposits from CAVA, biostratigraphic ages and sediment accumulation rates improved the age models for the drilling sites.
Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef
2017-10-01
The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P < 0.001). Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.
Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy
Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.
2004-01-01
Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular reconstructions were patent at last follow-up. With median follow-up of 26 months, 5 patients have died of recurrent malignancy at 44, 40, 32, 26, and 24 months, while an additional patient is alive with disease at 31 months. Actuarial 1-, 3-, and 5-year survivals were 85%, 60%, and 33%, respectively. Conclusions: IVC involvement by hepatic malignancy does not necessarily preclude resection. Liver resection with reconstruction of the inferior vena cava can be performed in selected cases. The increased risk associated with the procedure appears to be balanced by the possible benefits, particularly when the lack of alternative curative approaches is considered. PMID:15082976
Corrosion cast study of the canine hepatic veins.
Uršič, M; Vrecl, M; Fazarinc, G
2014-11-01
This study presents a detailed description of the distribution, diameters and drainage patterns of hepatic veins on the basis of the corrosion cast analysis in 18 dogs. We classified the hepatic veins in three main groups: the right hepatic veins of the caudate process and right lateral liver lobe, the middle hepatic veins of the right medial and quadrate lobes and the left hepatic veins of both left liver lobes and the papillary process. The corrosion cast study showed that the number of the veins in the Nomina Anatomica Veterinaria and most anatomical textbooks is underestimated. The number of various-sized hepatic veins of the right liver division ranged from 3 to 5 and included 1 to 4 veins from the caudate process and 2 to 4 veins from the right lateral liver lobe. Generally, in all corrosion casts, one middle-sized vein from the right part of the right medial lobe, which emptied separately in the caudal vena cava, was established. The other vein was a large-sized vein from the remainder of the central division, which frequently joined the common left hepatic vein from the left liver lobes. The common left hepatic vein was the largest of all the aforementioned hepatic veins.
Kaoutzanis, Christodoulos; Evangelakis, Erotokritos; Kokkinos, Chrysostomos; Kaoutzanis, Gavriel
2011-01-01
Traumatic injury to the retrohepatic veins continues to carry high mortality rates. In the last few decades various management strategies have been proposed. However, treatment of such injuries still remains highly variable and technically challenging due to the surgically inaccessible location of these vessels and the consequent difficulty controlling bleeding. We report a successful repair of complete transection of the two main extraparenchymal hepatic veins and laceration of the retrohepatic inferior vena cava using cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA) following blunt abdominal trauma. Immediate CPB with or without HCA can be life-saving and should be considered for patients with complex isolated retrohepatic venous injuries.
Harbuzova, V Iu
2002-01-01
The intensity of the lipid peroxydation (LPO) and the antioxidant enzyme activity (superoxide dismutase, glutathione peroxydase and catalase) on injecting vitamin D in high doses (10,000 U/kg) was examined in the arterial and venous walls of rabbits. The increase in the amount of the intermediate and final LPO products has been found in the vessels of all types. The lowest intensity of LPO was noted in the vena cava. The decrease in the antioxidant activity has been revealed. But vena cava inferior was the exception because the activity of all studied antioxidant enzymes grew in its wall. This increase is likely to be one of the reasons for vena resistance to the action of damaging factors.
RADIOGRAPHIC THORACIC ANATOMY OF THE RED PANDA (AILURUS FULGENS).
Makungu, Modesta; du Plessis, Wencke M; Barrows, Michelle; Groenewald, Hermanus B; Koeppel, Katja N
2016-09-01
The red panda ( Ailurus fulgens ) is classified as an endangered species by the International Union for Conservation of Nature and Natural Resources. The natural distribution of the red panda is in the Himalayas and southern China. Thoracic diseases such as dirofilariasis, hypertrophic cardiomyopathy, tracheal obstruction, lung worm infestation, and pneumonia have been reported in the red panda. The aim of this study was to describe the normal radiographic thoracic anatomy of captive red pandas as a species-specific reference for routine health examinations and clinical cases. Right lateral (RL) and dorsoventral (DV) inspiratory phase views of the thorax were obtained in 11 adult captive red pandas. Measurements were made and ratios calculated to establish reference ranges for the mean vertebral heart score on the RL (8.34 ± 0.25) and DV (8.78 ± 0.34) views and the mean ratios of the caudal vena cava diameter to the vertebral body length above tracheal bifurcation (0.67 ± 0.05) and tracheal diameter to the width of the third rib (2.75 ± 0.24). The majority of animals (10/11) had 14 thoracic vertebrae, except for one animal that had 15 thoracic vertebrae. Rudimentary clavicles were seen in 3/11 animals. The ovoid, oblique cardiac silhouette was more horizontally positioned and elongated in older animals. A redundant aortic arch was seen in the oldest animal. The trachea was seen with mineralized cartilage rings in all animals. The carina was clearly seen in the majority of animals (10/11). Variations exist in the normal radiographic thoracic anatomy of different species. Knowledge of the normal radiographic thoracic anatomy of the red panda should prove useful for routine health examinations and in the diagnosis of thoracic diseases.
Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A
2013-12-01
Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.
Aiyagari, Ranjit; Rhodes, John F.; Shrader, Peter; Radtke, Wolfgang A.; Bandisode, Varsha M.; Bergersen, Lisa; Gillespie, Matthew J.; Gray, Robert G.; Guey, Lin T.; Hill, Kevin D.; Hirsch, Russel; Kim, Dennis W.; Lee, Kyong-Jin; Pelech, Andrew N.; Ringewald, Jeremy; Takao, Cheryl; Vincent, Julie A.; Ohye, Richard G.
2014-01-01
Objective To compare interstage cardiac catheterization hemodynamic and angiographic findings between shunt types for Single Ventricle Reconstruction (SVR) trial. Background The SVR trial, which randomized subjects to modified Blalock-Taussig shunt (MBTS) or right ventricle-to-pulmonary artery shunt (RVPAS) for the Norwood procedure, demonstrated RVPAS was associated with smaller pulmonary artery diameter, but superior 12-month transplant-free survival. Methods We analyzed pre-stage II catheterization data for SVR trial subjects. Hemodynamic variables and shunt and pulmonary angiography were compared between shunt types; their association with 12-month transplant-free survival was also evaluated. Results Of 549 randomized subjects, 389 underwent pre-stage II catheterization. Smaller size, lower aortic and superior vena cava saturation, and higher ventricular end-diastolic pressure (EDP) were associated with worse 12-month transplant-free survival. MBTS subjects had lower coronary perfusion pressure (27mmHg vs. 32mmHg, P<0.001) and higher Qp:Qs ratio (1.1 vs. 1.0, P=0.009). Higher Qp:Qs ratio increased the risk of death or transplant only in the RVPAS group (P=0.01). MBTS subjects had fewer shunt (14% vs. 28%, P=0.004) and severe left pulmonary artery stenoses (0.7% vs. 9.2%, P=0.003), larger mid-main branch pulmonary artery diameters and higher Nakata index (164 vs. 134, P<0.001). Conclusions Compared with RVPAS subjects, MBTS subjects had more hemodynamic abnormalities related to shunt physiology, while RVPAS subjects had more shunt or pulmonary obstruction of a severe degree, and inferior pulmonary artery growth at pre-stage II catheterization. Lower BSA, higher ventricular EDP, and lower SVC saturation were associated with worse 12-month transplant-free survival. PMID:24332668
Pellicori, Pierpaolo; Kallvikbacka-Bennett, Anna; Khaleva, Olga; Carubelli, Valentina; Costanzo, Pierluigi; Castiello, Teresa; Wong, Kenneth; Zhang, Jufen; Cleland, John G F; Clark, Andrew L
2014-01-01
Many patients have clinical, structural or bio-marker evidence of heart failure (HF) but a normal left ventricular ejection fraction (LVEF; HeFNEF). Measurement of global longitudinal strain (GLS) may add diagnostic and prognostic information. Patients with symptoms suggesting heart failure and LVEF ≥50% were studied: 76 had no substantial cardiac dysfunction (left atrial diameter (LAD) <40 mm and amino-terminal pro-brain natriuretic peptide (NTproBNP) <400 ng/l); 99 had "possible HeFNEF" (LAD ≥40 mm or NTproBNP ≥400 ng/l); and 138 had "definite HeFNEF" (LAD ≥40 mm and NTproBNP ≥400 ng/L). Mean LVEF was 58% in each subgroup. Patients with definite HeFNEF were older, more likely to have atrial fibrillation, had more symptoms and signs of fluid retention, were more likely to have right ventricular dysfunction and had higher pulmonary pressures than other groups. Mean GLS (SD) was less negative in patients with definite HeFNEF (-13.6 (3.0)% vs. possible HeFNEF: -15.2 (3.1)% vs. no substantial cardiac dysfunction: -15.9 (2.4)%; p < 0.001). GLS was -19.1 (2.1)% in 20 controls. During a median follow up of 647 days, cardiovascular death or an unplanned hospitalisation for heart failure occurred in 62 patients. In univariable analysis, GLS but not LVEF predicted events. However, in a multi-variable analysis, only urea, NTproBNP, left atrial volume, inferior vena cava diameter and atrial fibrillation independently predicted adverse outcome. GLS is abnormal in patients who have other evidence of HeFNEF, is associated with a worse prognosis in this population but is not a powerful independent predictor of outcome.
Gul, Enes Elvin; Can, Ilknur; Guler, Ibrahim; Yesildag, Ahmet; Abdulhalikov, Turyan; Kayrak, Mehmet; Ozdemir, Kurtulus; Gok, Hasan
2012-01-01
Heart-type fatty acid binding protein (H-FABP) is a sensitive marker of myocardial injury and predictor of worse prognosis in patients with pulmonary embolism (PE). Assessment of right ventricular dysfunction and pulmonary artery obstruction index (PAOI) with computed tomography (CT) has been reported as a predictor of mortality in PE. Therefore, we aimed to assess the correlation between H-FABP and CT angiographic PAOI in PE patients at intermediate risk. Sixty-one patients (28 males; mean age, 62 ± 17 years) with diagnosis of PE were included in this study. CT was performed in all patients, and the following parameters were evaluated: right ventricle/left ventricle ratio (RV/LV), pulmonary artery axial diameter, superior vena cava axial diameter, and PAOI determined with Qanadli score. Blood samples were assessed for H-FABP and troponin levels. Patients were followed for 30 days after discharge. Mean PAOI was 57 ± 18%. Eleven patients died during the follow-up period due to PE (18% mortality rate). H-FABP was positive in 21 patients (35%). There was no difference in CT parameters between patients with positive H-FABP and negative H-FABP. In addition, CT parameters were similar between patients who survived and those who did not. RV/LV ratio correlated with PAOI score. Among the biomarkers, troponin levels correlated with both RV/LV ratio and PAOI. H-FABP was an independent predictor of mortality. PAOI and RV/LV ratio did not predict 30-day mortality. Although H-FABP positivity confers a bad prognosis on PE patients at intermediate risk, PAOI did not predict mortality in this group.
Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R
2017-01-01
Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.
Sharp Central Venous Recanalization by Means of a TIPS Needle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Honnef, Dagmar, E-mail: honnef@rad.rwth-aachen.de; Wingen, Markus; Guenther, Rolf W.
The purpose of this study was to perform an alternative technique for recanalization of a chronic occlusion of the left brachiocephalic vein that could not be traversed with a guidewire. Restoration of a completely thrombosed left brachiocephalic vein was attempted in a 76-year-old male hemodialysis patient with massive upper inflow obstruction, massive edema of the face, neck, shoulder, and arm, and occlusion of the stented right brachiocephalic vein/superior vena cava. Vessel negotiation with several guidewires and multipurpose catheters proved unsuccessful. The procedure was also non-viable using a long, 21G puncture needle. Puncture of the superior vena cava (SVC) at themore » distal circumference of the stent in the right brachiocephalic vein/superior vena cava, however, was feasible with a transjugular intrahepatic portosystemic shunt (TIPS) set under biplanar fluoroscopy using the distal end of the right brachiocephalic vein as a target, followed by balloon dilatation and partial extraction of thrombotic material of the left brachiocephalic vein with a wire basket. Finally, two overlapping stents were deployed to avoid early re-occlusion. Venography demonstrated complete vessel patency with free contrast media flow via the stents into the SVC, which was reconfirmed in follow-up examinations. Immediate clinical improvement was observed. Venous vascular recanalization of chronic venous occlusion by means of a TIPS needle is feasible as a last resort under certain precautions.« less
Quintini, Cristiano; Miller, Charles M; Hashimoto, Koji; Philip, Ding; Uso, Teresa Diago; Aucejo, Federico; Kelly, Dympna; Winans, Charles; Eghtesad, Bijan; Vogt, David; Fung, John
2009-01-01
Venous outflow obstruction is a rare but potentially lethal complication after orthotopic liver transplantation (OLT) with the "piggyback" technique. Therapeutic options include angioplasty with or without stent placement, surgical reconstruction of the venous anastomosis, and retransplantation. Surgical options are technically very challenging and the outcomes discouraging. We describe here two cases of venous outflow obstruction in recipients of piggyback liver grafts, one involving both the vena cava and hepatic veins and the other affecting only hepatic vein outflow. Both patients were treated successfully with side-to-side cavo-cavostomy using an endovascular (endo-GIA) stapler. This novel technique is fast and effective in resolving the outflow obstruction. Copyright 2008 AASLD.
Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A
2017-06-01
This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Bromine release during Plinian eruptions along the Central American Volcanic Arc
NASA Astrophysics Data System (ADS)
Hansteen, T. H.; Kutterolf, S.; Appel, K.; Freundt, A.; Perez-Fernandez, W.; Wehrmann, H.
2010-12-01
Volcanoes of the Central American Volcanic Arc (CAVA) have produced at least 72 highly explosive eruptions within the last 200 ka. The eruption columns of all these “Plinian” eruptions reached well into the stratosphere such that their released volatiles may have influenced atmospheric chemistry and climate. While previous research has focussed on the sulfur and chlorine emissions during such large eruptions, we here present measurements of the heavy halogen bromine by means of synchrotron radiation induced micro-XRF microanalysis (SR-XRF) with typical detection limits at 0.3 ppm (in Fe rich standard basalt ML3B glass). Spot analyses of pre-eruptive glass inclusions trapped in minerals formed in magma reservoirs were compared with those in matrix glasses of the tephras, which represent the post-eruptive, degassed concentrations. The concentration difference between inclusions and matrix glasses, multiplied by erupted magma mass determined by extensive field mapping, yields estimates of the degassed mass of bromine. Br is probably hundreds of times more effective in destroying ozone than Cl, and can accumulate in the stratosphere over significant time scales. Melt inclusions representing deposits of 22 large eruptions along the CAVA have Br contents between 0.5 and 13 ppm. Br concentrations in matrix glasses are nearly constant at 0.4 to 1.5 ppm. However, Br concentrations and Cl/Br ratios vary along the CAVA. The highest values of Br contents (>8 ppm) and lowest Cl/Br ratios (170 to 600) in melt inclusions occur across central Nicaragua and southern El Salvador, and correlate with bulk-rock compositions of high Ba/La > 85 as well as low La/Yb <5. Thus we observe the maximum magmatic Br-concentrations in the segements of the arc. where the input of sediment and water into the subduction system is largest and the melting column is longest. The largest eruptive emissions of Br into the atmosphere, however, occurred in Guatemala due to the large magnitude of eruptions. The most prominent example is the 84 ka Los Chocoyos eruption from Atitlán Caldera, which discharged 700 kilotons of Br. On average, each of the remaining 21 CAVA eruptions studied have discharged c.100 kilotons of bromine. During the past 200 ka, CAVA volcanoes have emitted a cumulative mass of 3.2 Mt of Br through highly explosive eruptions. There are six periods in the past (c. 2ka, 6ka, 25ka, 40ka, 60ka, 75ka) when up to four larger eruptions occurred within only several hundred years. The heavy halogen release of these eruptions may have had a cumulative effect on the atmosphere which is presently investigated by climate/atmosphere models based on our analyses as input data.
Cardiopulmonary Syndromes (PDQ®)—Health Professional Version
Cardiopulmonary syndromes (dyspnea, chronic cough, pleural and pericardial effusion, and superior vena cava syndrome) can occur in certain cancers. Get comprehensive information about these syndromes in this summary for clinicians.
Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.
Chen, Lei; Hsiao, Allen; Langhan, Melissa; Riera, Antonio; Santucci, Karen A
2010-10-01
Prospectively identifying children with significant dehydration from gastroenteritis is difficult in acute care settings. Previous work by our group has shown that bedside ultrasound (US) measurement of the inferior vena cava (IVC) and the aorta (Ao) diameter ratio is correlated with intravascular volume. This study was designed to validate the use of this method in the prospective identification of children with dehydration by investigating whether the IVC/Ao ratio correlated with dehydration in children with acute gastroenteritis. Another objective was to investigate the interrater reliability of the IVC/Ao measurements. A prospective observational study was carried out in a pediatric emergency department (PED) between November 2007 and June 2009. Children with acute gastroenteritis were enrolled as subjects. A pair of investigators obtained transverse images of the IVC and Ao using bedside US. The ratio of IVC and Ao diameters (IVC/Ao) was calculated. Subjects were asked to return after resolution of symptoms. The difference between the convalescent weight and ill weight was used to calculate the degree of dehydration. Greater than or equal to 5% difference was judged to be significant. Linear regression was performed with dehydration as the dependent variable and the IVC/Ao as the independent variable. Pearson's correlation coefficient was calculated to assess the degree of agreement between observers. A total of 112 subjects were enrolled. Seventy-one subjects (63%) completed follow-up. Twenty-eight subjects (39%) had significant dehydration. The linear regression model resulted in an R² value of 0.21 (p < 0.001) and a slope (B) of 0.11 (95% confidence interval [CI] = 0.08 to 0.14). An IVC/Ao cutoff of 0.8 produced a sensitivity of 86% and a specificity of 56% for the diagnosis of significant dehydration. Forty-eight paired measurements of IVC/Ao ratios were made. The Pearson correlation coefficient was 0.76. In this pilot study the ratio of IVC to Ao diameters, as measured by bedside US, was a marginally accurate measurement of acute weight loss in children with dehydration from gastroenteritis. The technique demonstrated good interrater reliability. © 2010 by the Society for Academic Emergency Medicine.
Cardiopulmonary Syndromes (PDQ®)—Patient Version
Expert-reviewed information summary about common conditions that produce chest symptoms. The cardiopulmonary syndromes addressed in this summary are cancer-related dyspnea, malignant pleural effusion, pericardial effusion, and superior vena cava syndrome.
Cardiopulmonary Syndromes (PDQ®)—Health Professional Version
Expert-reviewed information summary about common conditions that produce chest symptoms. The cardiopulmonary syndromes addressed in this summary are cancer-related dyspnea, malignant pleural effusion, pericardial effusion, and superior vena cava syndrome.
Doshi, Mehul Harshad; Narayanan, Govindarajan
2016-12-01
Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.
Pheochromocytoma with inferior vena cava thrombosis: An unusual association.
Kota, Sunil K; Kota, Siva K; Jammula, Sruti; Meher, Lalit K; Modi, Kirtikumar D
2012-04-01
Pheochromocytomas have been described in association with vascular abnormalities like renal artery stenosis. A 48-year-old man was admitted to our hospital with the complaints of headache, sweating, anxiety, dizziness, nausea, vomiting and hypertension. For last several days, he was having a dull aching abdominal pain. Abdominal computed tomography (CT) revealed the presence of a left adrenal pheochromocytoma. An inferior vena cava (IVC) venogram via the right jugular vein demonstrated occlusion of the IVC inferior to the right atrium. Surgical removal of pheochromocytoma was done, followed by anticoagulant treatment for IVC thrombosis, initially with subcutaneous low molecular weight heparin, and then with oral warfarin, resulting in restoration of patency. To the best of our knowledge, the occurrence of pheochromocytoma in IVC thrombosis has not been reported so far from India. Possible mechanisms of such an involvement are discussed.
2D array transducers for real-time 3D ultrasound guidance of interventional devices
NASA Astrophysics Data System (ADS)
Light, Edward D.; Smith, Stephen W.
2009-02-01
We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.
Kleber, E; Schneider, W; Schäfer, H L; Elstner, E F
1995-02-01
Aqueous-alcoholic extracts from Eschscholtzia californica inhibit the enzymatic degradation of catecholamines as well as the synthesis of adrenaline, whereas aqueous-ethanolic extracts from Corydalis cava enhance the chemical oxidation of adrenaline and the synthesis of melanine from dihydroxyphenylalanine (DOPA). Both extracts dramatically shorten the lag phase in the catalysis of phenolase probably due to their o-diphenol content, where the Corydalis extracts are 10 times more active than the Eschscholtzia preparations. Dopamine beta-hydroxylase and monoamine oxidase (MAO-B) are especially inhibited by Eschscholtzia extracts. Diamine oxidases are inhibited by both preparations to a similar extent. The results of this study may be interpreted as a cooperative function of the two preparations in establishing and preserving high catecholamine levels thus explaining their sedative, antidepressive and hypnotic activities.
Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.
Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin
2016-12-01
Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Atar, İlyas; Karaçağlar, Emir; Özçalık, Emre; Özin, Bülent; Müderrisoğlu, Haldun
2015-06-01
Presence of a persistent left superior vena cava (PLSVC) is generally clinically asymptomatic and discovered incidentally during central venous catheterization. However, PLSVC may cause technical difficulties during cardiac device implantation. An 82-year-old man with heart failure symptoms and an ejection fraction (EF) of 20% was scheduled for resynchronization therapy-defibrillator device (CRT-D) implantation. A PLSVC draining via a dilated coronary sinus into an enlarged right atrium was diagnosed. First, an active-fixation right ventricular lead was inserted into the right atrium through the PLSVC. The stylet was preshaped to facilitate its passage to the right ventricular apex. An atrial lead was positioned on the right atrium free wall, and an over-the-wire coronary sinus lead deployed to a stable position. CRT-D implantation procedure was successfully completed.
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-06-04
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
CT of inferior vena cava filters: normal presentations and potential complications.
Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man
2015-12-01
With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.
Kaul, Pankaj; Adluri, Krishna; Javangula, Kalyana; Baig, Wasir
2009-01-01
A 59 year old man underwent mechanical tricuspid valve replacement and removal of pacemaker generator along with 4 pacemaker leads for pacemaker endocarditis and superior vena cava obstruction after an earlier percutaneous extraction had to be abandoned, 13 years ago, due to cardiac arrest, accompanied by silent, unsuspected right atrial perforation and exteriorisation of lead. Postoperative course was complicated by tricuspid valve thrombosis and secondary pulmonary embolism requiring TPA thrombolysis which was instantly successful. A review of literature of pacemaker endocarditis and tricuspid thrombosis along with the relevant management strategies is presented. We believe this case report is unusual on account of non operative management of right atrial lead perforation following an unsuccessful attempt at percutaneous removal of right sided infected pacemaker leads and the incidental discovery of the perforated lead 13 years later at sternotomy, presentation of pacemaker endocarditis with a massive load of vegetations along the entire pacemaker lead tract in superior vena cava, right atrial endocardium, tricuspid valve and right ventricular endocardium, leading to a functional and structural SVC obstruction, requirement of an unusually large dose of warfarin postoperatively occasioned, in all probability, by antibiotic drug interactions, presentation of tricuspid prosthetic valve thrombosis uniquely as vasovagal syncope and isolated hypoxia and near instantaneous resolution of tricuspid prosthetic valve thrombosis with Alteplase thrombolysis. PMID:19239701
Kim, Sang; Kunkel, Scott; Browske, Kristin
2018-01-01
Anomalies of the inferior vena cava (AIVC) are rare but well-recognized anatomic abnormalities that can lead to clinically significant deep vein thrombosis (DVT) in a subset of otherwise healthy patients. This report illustrates an uncommon congenital anomaly that military clinicians should consider when evaluating unprovoked DVT in young patients. Single case report and literature review. We describe a case of a 24-yr-old United States Marine who presented with abdominal pain for 2 wk. After conservative therapy failed, a contrast-enhanced abdominal computed tomography (CT) scan was performed. The CT scan revealed an absent inferior vena cava with evidence of right venous thrombophlebitis. We include four contrast-enhanced helical CT scans that illustrate this phenomenon. Due to the lack of available studies and data, we do not know the relative risk of DVT in patients with AIVC. However, the literature review suggests that there is a pro-thrombogenic effect of this congenital anomaly. Clinicians should include AIVC in their differential when treating young, otherwise healthy patients with unprovoked DVT. This population is much more likely to have an AIVC than the general population. In addition to thrombophilia markers, a contrast-enhanced CT scan should be considered as part of the initial workup. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Paffenholz, P; Pfister, D; Heidenreich, A
2016-05-01
Postchemotherapy residual tumour resection (PC-RTR) is an integral part of the multimodal therapy for advanced testicular germ cell tumours. Depending on the extent and localisation of the residual mass, PC-RTR may necessitate a multidisciplinary procedure (which should be planned preoperatively), to resolve even complex situations in an oncologically sound manner, with lower treatment-related morbidity The aim of article is to report on the interdisciplinary management of complex residual masses. Of a total of 162 patients who underwent PC-RTR, 24 (17.8 %) patients underwent, in addition to a bilateral postchemotherapy retroperitoneal lymphadenectomy (PC-RPLND), complex adjunctive resections including the abdominal aorta, the inferior vena cava, or the thoracic/lumbar spine, and the neighbouring vessels (n = 15). We performed a retrospective analysis of treatment-associated complications according to the Clavien-Dindo classification and of progression-free, cancer-specific and overall survival. Median patient age was 24.5 (18-52) years. All patients had an intermediate or poor prognosis according to the International Germ Cell Cancer Collaboration Group (IGCCCG). Median tumour diameter at the time of surgery was 18.6 (9.0-35) cm. In 5 patients 1-2 metastatic lumbar vertebral bodies were completely resected, stabilised and replaced by means of a cage. In 6 patients resection of the abdominal aorta/inferior vena cava with vascular prosthesis replacement was required owing to infiltration. In 2 patients the common iliac artery or vein was resected and replaced. In addition, retrocrural lymph nodes had to be resected in 5 patients and 3 patients required adjunctive nephrectomy. In another 4 patients the Whipple procedure was required owing to infiltration into the pancreas and/or duodenum. The median operating time was 7.8 (6-15) h, the median blood loss was around 1,450 (900-3,400) ml, and 2 Clavien-Dindo grade IVa complications occurred. Pathohistology revealed teratoma/vital cancer in 16/24 patients and scarring/necrosis in 8 patients. After a median follow-up of 2.5 years, 1 patient developed recurrent disease and 1 patient died of the disease. Postchemotherapy, a few patients with advanced nonseminomas (NS) need complex residual tumour resection in an interdisciplinary setting, with a good functional and oncological outcome. Even the involvement of vascular vertebral structures does not constitute a contraindication for complete resection.
Validation of semi-automatic segmentation of the left atrium
NASA Astrophysics Data System (ADS)
Rettmann, M. E.; Holmes, D. R., III; Camp, J. J.; Packer, D. L.; Robb, R. A.
2008-03-01
Catheter ablation therapy has become increasingly popular for the treatment of left atrial fibrillation. The effect of this treatment on left atrial morphology, however, has not yet been completely quantified. Initial studies have indicated a decrease in left atrial size with a concomitant decrease in pulmonary vein diameter. In order to effectively study if catheter based therapies affect left atrial geometry, robust segmentations with minimal user interaction are required. In this work, we validate a method to semi-automatically segment the left atrium from computed-tomography scans. The first step of the technique utilizes seeded region growing to extract the entire blood pool including the four chambers of the heart, the pulmonary veins, aorta, superior vena cava, inferior vena cava, and other surrounding structures. Next, the left atrium and pulmonary veins are separated from the rest of the blood pool using an algorithm that searches for thin connections between user defined points in the volumetric data or on a surface rendering. Finally, pulmonary veins are separated from the left atrium using a three dimensional tracing tool. A single user segmented three datasets three times using both the semi-automatic technique as well as manual tracing. The user interaction time for the semi-automatic technique was approximately forty-five minutes per dataset and the manual tracing required between four and eight hours per dataset depending on the number of slices. A truth model was generated using a simple voting scheme on the repeated manual segmentations. A second user segmented each of the nine datasets using the semi-automatic technique only. Several metrics were computed to assess the agreement between the semi-automatic technique and the truth model including percent differences in left atrial volume, DICE overlap, and mean distance between the boundaries of the segmented left atria. Overall, the semi-automatic approach was demonstrated to be repeatable within and between raters, and accurate when compared to the truth model. Finally, we generated a visualization to assess the spatial variability in the segmentation errors between the semi-automatic approach and the truth model. The visualization demonstrates the highest errors occur at the boundaries between the left atium and pulmonary veins as well as the left atrium and left atrial appendage. In conclusion, we describe a semi-automatic approach for left atrial segmentation that demonstrates repeatability and accuracy, with the advantage of significant time reduction in user interaction time.
NASA Astrophysics Data System (ADS)
Verma, Aekaansh; Shang, Jessica; Esmaily-Moghadam, Mahdi; Wong, Kwai; Marsden, Alison
2016-11-01
Babies born with a single functional ventricle typically undergo three open-heart surgeries starting as neonates. The first of these stages (BT shunt or Norwood) has the highest mortality rates of the three, approaching 30%. Proceeding directly to a stage-2 Glenn surgery has historically demonstrated inadequate pulmonary flow (PF) & high mortality. Recently, the Assisted Bi-directional Glenn (ABG) was proposed as a promising means to achieve a stable physiology by assisting the PF via an 'ejector pump' from the systemic circulation. We present preliminary parametrization and optimization results for the ABG geometry, with the goal of increasing PF. To limit excessive pressure increases in the Superior Vena Cava (SVC), the SVC pressure is included as a constraint. We use 3-D finite element flow simulations coupled with a single ventricle lumped parameter network to evaluate PF & the pressure constraint. We employ a derivative free optimization method- the Surrogate Management Framework, in conjunction with the OpenDIEL framework to simulate multiple simultaneous evaluations. Results show that nozzle diameter is the most important design parameter affecting ABG performance. The application of these results to patient specific situations will be discussed. This work was supported by an NSF CAREER award (OCI1150184) and by the XSEDE National Computing Resource.
Anatomic Suitability for Transcaval Access Based on Computed Tomography.
Lederman, Robert J; Greenbaum, Adam B; Rogers, Toby; Khan, Jaffar M; Fusari, Melissa; Chen, Marcus Y
2017-01-09
Transcaval access has been used successfully for over 200 transcatheter aortic valve replacements, large-bore percutaneous left ventricular assist devices, and thoracic endovascular aortic aneurysm repairs. This review teaches how to plan transcaval access and closure based on computed tomography. The main planning goals are to: 1) identify calcium-free crossing targets in the abdominal aorta along with optimal fluoroscopic projection angles and level with respect to lumbar vertebrae; 2) identify obstacles such as interposed bowel or pedunculated aortic atheroma; 3) plan covered stent bailout; and 4) identify jeopardized vascular branches such as renal arteries that might be obstructed by bailout covered stents if employed. The aorta and inferior vena cava are segmented (sculpted) using an image reconstruction workstation and crossing targets are highlighted. Important measurements such as aortic lumen diameter and target distance from renal arteries, aortoiliac bifurcation, and right femoral vein puncture site are reported to assist the operator. The proposed classification for transcaval feasibility has been revised, making some previously unfavorable candidates now feasible or favorable based on procedural success to date. Transcaval access allows percutaneous introduction of large devices into the aorta despite small or diseased iliofemoral arteries. By following these simplified procedures, both operators and imaging specialists can easily prepare comprehensive treatment plans. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.
Kalinin, R E; Suchkov, I A; Pshennikov, A S; Agapov, A B
2016-01-01
To assess the effectiveness of anticoagulant therapy (ACT) for the treatment of patients with deep venous thrombosis (DVT) of the lower extremities. The study considered ultrasonic characteristics of lysis of the proximal part of thrombus: localization and nature of venous thrombosis, the length and diameter of the proximal floating part of the thrombus, and duration of the venous thrombosis. Depending on the ACT options patients were divided into 3 groups: Group 1 (18 patients) received rivaroxaban, group 2 (19 patients) received enoxaparin sodium with subsequent transition to warfarin, and 3 group (19 patietns) received enoxaparin sodium, followed by administration of rivaroxaban. Treatment with rivaroxaban was preferable over standard ACT with enoxaparin/warfarin with regards to the lysis of thrombus when duration of thrombosis did not exceed 10 days. In 10.5% of patients who received warfarin flotation of thrombi remained for 14 days; the length of the floating part of the thrombi did not exceed 3 cm. Such circumstances and inability to reach a therapeutic INR value required cava filter placement. Treatment with enoxaparin sodium followed by the administration of rivaroxaban was found to be the most efficient ACT regimen as there was no negative dynamics of ultrasound characteristics of lysis of thrombi at any duration of the disease.
Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew
2014-01-01
Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.
Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L
2010-02-01
A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.
2014-01-01
Endocarditis is a type of infection that is common in internal medicine wards and in haemodialysis clinics. The location that is most affected are the heart valves. Herein, we report a case of an uncommon abscess, a sub-endothelial abscess between the transition of the superior vena cava and the right atrium. There were several emboli to the lung and foot, and the agent was related to Staphylococcus aureus and a double-lumen catheter. Usually, this type of abscess is located in valves, either the tricuspid valve if related to catheters or injection drug use or the mitral valve if related to other causes. An exhaustive review was made, but we found no information about the location of this abscess and the rarity of the event motivating the report of infection. PMID:25110520
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Ozkan, Ugur; Tercan, Fahri
2007-04-15
We present the case of a 14-year-old girl who developed acute deep vein thrombosis (DVT) in her right lower extremity. Laboratory testing revealed protein S deficiency, and the patient's father also had this abnormality with a history of lower extremity DVT. Manual thromboaspiration followed by catheter-directed thrombolysis resulted in total clearance of all thrombi. Computed tomography and later venography revealed an interrupted inferior vena cava. Catheter-directed thrombolysis is an established treatment for adults with acute DVT. To the best of our knowledge, this report is the first to describe catheter-directed thrombolysis in a pediatric patient with lower extremity DVT. Ourmore » results suggest that catheter-directed thrombolysis is safe and effective for use in selected older children and adolescents with acute DVT in the lower extremity.« less
Congenital cardiac malformations in relation to central venous access.
Thompson, Christine
During the third and seventh weeks of gestation, teratogenic exposure may lead to fetal abnormality such as congenital heart defects or intrauterine death. Congenital heart defects are present from birth, but may appear at any time, or only revealed postmortem. Often defects are present by degree. Some defects are life-threatening, while other, less severe conditions, may have minimal physiological impact. Left superior vena cava exists in early embryonic development, but the vessel degenerates as the cardiovascular system matures. When not associated with other malformations, an incidence of persistent left-sided superior vena cava (PLSVC) has no clinical signs or symptoms. However, it may not be as innocuous as it appears due to its association with the cyanotic defect, tetralogy of Fallot (TOF). Using a case history as an illustration it can be shown that all cases of defect or chromosomal suspicion should be documented as there may be implications for future interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel
A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less
Intravenous leiomyomatosis of the uterus with extension to the right heart
2011-01-01
A 42-year-old woman admitted with debilitation and engorgement both lower extremities. Transthoracic two-dimensional echocardiography, abdominal ultrasound and computerized tomography revealed a lobulated pelvic mass, a mass within right internal iliac vein, both common iliac vein, as well as the inferior vena cava, extending into the right atrium. In addition, echocardiography and abdominal ultrasound showed the tumor of right atrium and inferior vena cave has no stalk and has well-demarcated borders with the wall of right atrium and inferior vena cave. Hence, the presumptive diagnosis of IVL was made by echocardiography and abdominal ultrasound and the presumptive diagnosis of sarcoma with invasion in right internal iliac vein, both common iliac vein, the inferior vena cava, as well as the right atrium was made by multi-detector-row computerized tomography. The patient underwent a one-stage combined multidisciplinary thoraco-abdominal operation under general anaesthetic. Subsequently the pathologic report confirmed IVL. PMID:21943238
Partial anomalous pulmonary venous drainage. A novel approach to repair.
Hanhan, U A; Moodie, D S; Gill, C C; Sterba, R; Currie, P; Stewart, R
1989-01-01
Isolated partial anomalous pulmonary venous drainage with an intact atrial septum is a rare finding. The authors describe their experience with three patients (ages 9, 37, and 54 years), with partial anomalous pulmonary venous connection to the superior vena cava, right atrium, and inferior vena cava, who underwent extracardiac conduit repair of this anomaly. In all three patients, a synthetic Gortex graft was used for reconstruction of the venous pathways to the left atrium. The follow-up period ranged from 10 to 82 months (mean, 42 months). All three patients were evaluated with intravenous digital angiography, transesophageal echocardiography, or both at 10, 33, and 82 months postoperatively. Patency of the grafts with no evidence of obstruction and excellent pulmonary venous flow was shown. This surgical technique is an excellent option for correction of this anomaly, and intravenous digital subtraction angiography is a useful diagnostic tool during the postoperative period to evaluate patency of the repair.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel, E-mail: danielthomascookson@yahoo.co.uk; Caldwell, Stuart, E-mail: stuart.caldwell@middlemore.co.nz
Phlegmasia caerulea dolens (PCD) is a potentially disastrous complication of inferior vena cava filter insertion, and its optimum management has not been clearly established. We present a case report of a patient with pulmonary embolism and acute adrenal haemorrhage who developed PCD secondary to massive iliocaval thrombosis after insertion of a Cook Celect removable filter. Local intravenous catheter-directed thrombolysis (CDT), followed by systemic anticoagulation, achieved limb salvage and virtual resolution of symptoms at 3 months without complications. CDT can be a successful primary treatment of filter-associated PCD and can be safe in selected patients with acute nontraumatic haemorrhage. Systemic anticoagulationmore » may subsequently restore complete venous patency and may therefore be a useful approach to postthrombolysis management of residual iliocaval thrombus when filter removal is indicated.« less
Abu Akar, Firas Emad; Yang, Chenlu; Zhou, Yiming; Lin, Lei; Gonzalez-Rivas, Diego
2017-01-01
Interrupted IVC (also known as Azygos continuation of the inferior vena cava) is a relatively uncommon congenital condition with prevalence 1.5% (0.2–3%) of the general population (Bass et al.). Although it’s usually asymptomatic condition, splenic or cardiac abnormalities could be associated (Hardwick et al.). Incidental diagnosis during prenatal ultrasound screening or by routine imaging is the most common scenario. Special attention is required during right side thoracic procedures surgical resections in order to avoid scarifying the azygos vein that could lead to fatal results (Effler et al.). We herein report a video documented case of right upper lobectomy and mediastinal lymph node dissection for non-small cell carcinoma of lung in a patient who had interrupted hepatic segmental branch of the IVC. The procedure was performed via the subxiphoid uniportal VATS approach. PMID:29078654
Bangash, Sohail Khan; Pathan, Iqbal Hussain; Zaki, Saad Bader
2016-10-01
A heart with two atriums but one ventricle, an anatomy with a unique physiology, is responsible for many creative surgical and interventional approaches in history. Different surgical techniques have been used to address this strange physiology of parallel circulation. All these attempts met with failure till the concept of Fontan circulation was described. Currently, controversy exists between multistage vs. single stage total cavopulmonary connections. Total cavopulmonary connection is the only definitive procedure performed to provide palliation for patients with complex congenital heart defects which cannot support a biventricular circulation. We report a case with tricuspid atresia with transposition of great arteries and pulmonary stenosis with persistant left-sided superior vena cava and functionally single ventricle. Patient successfully underwent single stage extra-cardiac total cavopulmonary connection. In this case, bilateral Glenn with extra-cardiac inferior vena cava to main pulmonary artery shunt was performed off-pump.
Cor triatriatum dexter: A rare cause of cyanosis during neonatal period.
Alghamdi, Mohammed Hussien
2016-01-01
Cor-triatriatum dexter is an extremely rare congenital heart defect in which there is complete persistence of the right valve of embryonic sinus venosus that results in partitioning of the right atrium into a smooth and trabeculated portion. The smooth portion receives venous blood from inferior vena cava, superior vena cava, and coronary sinus while the trabeculated portion contains the right atrial appendage and the opening of tricuspid valve. We report a 1-week-old child who presented with intermittent episodes of central cyanosis. Echocardiography, established, and bubble contrast study confirmed the diagnosis of an isolated cor-triatriatum dexter. The baby initially underwent an intervention by cardiac catheterization, which was unsuccessful in disrupting the membrane and re-direct the systemic venous flow to the right heart chambers. She subsequently had the cor-triatriatum dexter membrane resected via an uncomplicated open-heart surgery.
González, Javier; Angulo, J; Ciancio, G
2011-04-01
Renal cell cancer with tumor thrombus is present in 4-15% of cases. The prognostic significance of this entity has been object of intense debate. Nowadays, it is considered, that the presence of thrombus itself does not have a negative prognostic impact on survival rates if the thrombus could be excised satisfactorily. Complete removal of renal malignant tissue is the only curative strategy for the treatment of this kind of tumors. During the last three decades, there has been steady improvements in surgical technique and preoperative care fields that have favorably modified the surgeons' ability to safely excise these tumors. In this sense, the experience provided by multiorgan, kidney-pancreas and liver procurement and transplantation techniques led the urologists reexamine their approaches to the inferior vena cava and retroperitoneum, thus they could result useful in the always challenging resection of these complex tumors with neoplasic extension into the vena cava.
Morphological study of the innervation pattern of the rabbit sinoatrial node
NASA Technical Reports Server (NTRS)
Roberts, L. A.; Slocum, G. R.; Riley, D. A.
1989-01-01
The pattern of sinoatrial (SA) node innervations in rabbit was elucidated using a newly developed highly reproducible cholinesterase/silver impregnation staining procedure which made it possible to delineate large nerves, fine processes, and ganglion cells. The SA node and dominant pacemaker sites were identified by microelectrode recording. A generalized pattern of innnervation was recognized, which includes a large ganglionic complex inferior to the SA node; two or more moderately large nerves traversing the SA node parallel to the crista terminalis; nerves entering the intercaval region from the septum, the superior vena cava, and the inferior vena cava to impinge on the SA node; and a fine network of nerve processes, which was particularly dense in the SA node. From the location and distribution of the nerves and ganglionic branches, it can be inferred that the neural network in the intercaval region is capable of performing complex modulatory and integrative functions among the structures within this region.
Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng
2018-04-11
A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.
Smodlaka, H; Henry, R W; Reed, R B
2009-06-01
The ringed seal [Pusa (Phoca) hispida], as well as other seals, exhibits unique anatomical properties when compared to its terrestrial counterparts. In the ringed seal, the most conspicuous marine adaptation is the aortic bulb. This large dilatation of the ascending aorta is comparable to that found in other seal species and marine mammals. The branches of the ascending aorta (brachiocephalic trunk, left common carotid artery and left subclavian artery) are similar to those of higher primates and man. The peculiarities of the venous system are: three pulmonary veins, a pericardial venous plexus, a caval sphincter, a hepatic sinus with paired caudal vena cavae and a large extradural venous plexus. Generally, three common pulmonary veins (right, left and caudal) empty into the left atrium. The pericardial venous plexus lies deep to the mediastinal pericardial pleura (pleura pericardica) on the auricular (ventral) surface of the heart. The caval sphincter surrounds the caudal vena cava as it passes through the diaphragm. Caudal to the diaphragm, the vena cava is dilated (the hepatic sinus), and near the cranial extremity of the kidneys, it becomes biphid. The azygos vein is formed from the union of the right and left azygos veins at the level of the 5th thoracic vertebra. Cardiovascular physiological studies show some of these anatomical variations, especially of the venous system and the ascending aorta, to be modifications for diving. This investigation documents the large blood vessels associated with the heart and related structures in the ringed seal.
Management and outcome of cardiac and endovascular cystic echinococcosis.
Díaz-Menéndez, Marta; Pérez-Molina, José Antonio; Norman, Francesca Florence; Pérez-Ayala, Ana; Monge-Maillo, Begoña; Fuertes, Pilar Zamarrón; López-Vélez, Rogelio
2012-01-01
Cystic echinococcosis (CE) can affect the heart and the vena cava but few cases are reported. A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995-2009) is reported. Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4-93 months). One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE) and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas. © 2012 Díaz-Menéndez et al.
Management and Outcome of Cardiac and Endovascular Cystic Echinococcosis
Díaz-Menéndez, Marta; Pérez-Molina, José Antonio; Norman, Francesca Florence; Pérez-Ayala, Ana; Monge-Maillo, Begoña; Fuertes, Pilar Zamarrón; López-Vélez, Rogelio
2012-01-01
Background Cystic echinococcosis (CE) can affect the heart and the vena cava but few cases are reported. Methods A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995–2009) is reported. Results Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4–93 months). One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE) and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. Conclusions Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas. PMID:22235354
The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ray, Charles E.; Prochazka, Allan
Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less
Abnormal gel flotation caused by contrast media during adrenal vein sampling.
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare
2016-10-15
During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to confirm the catheter's position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm 3 of density, was used close to the right adrenal vein due to some difficulty to access it. The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays.
Cardiopulmonary Syndrome Overview
... to Cancer Off-Label Drug Use Access to Experimental Drugs Complementary & Alternative Medicine (CAM) CAM for Patients ... pressure on the heart. Treatment may be to control the symptoms of ... vena cava syndrome (SVCS) is a group of signs and symptoms that occur when the ...
Differential regulation of cell functions by CSD peptide subdomains
2013-01-01
Background In fibrotic lung diseases, expression of caveolin-1 is decreased in fibroblasts and monocytes. The effects of this deficiency are reversed by treating cells or animals with the caveolin-1 scaffolding domain peptide (CSD, amino acids 82–101 of caveolin-1) which compensates for the lack of caveolin-1. Here we compare the function of CSD subdomains (Cav-A, Cav-B, Cav-C, Cav-AB, and Cav-BC) and mutated versions of CSD (F92A and T90A/T91A/F92A). Methods Migration toward the chemokine CXCL12 and the associated expression of F-actin, CXCR4, and pSmad 2/3 were studied in monocytes from healthy donors and SSc patients. Fibrocyte differentiation was studied using PBMC from healthy donors and SSc patients. Collagen I secretion and signaling were studied in fibroblasts derived from the lung tissue of healthy subjects and SSc patients. Results Cav-BC and CSD at concentrations as low as 0.01 μM inhibited the hypermigration of SSc monocytes and TGFβ-activated Normal monocytes and the differentiation into fibrocytes of SSc and Normal monocytes. While CSD also inhibited the migration of poorly migrating Normal monocytes, Cav-A (and other subdomains to a lesser extent) promoted the migration of Normal monocytes while inhibiting the hypermigration of TGFβ-activated Normal monocytes. The effects of versions of CSD on migration may be mediated in part via their effects on CXCR4, F-actin, and pSmad 2/3 expression. Cav-BC was as effective as CSD in inhibiting fibroblast collagen I and ASMA expression and MEK/ERK signaling. Cav-C and Cav-AB also inhibited collagen I expression, but in many cases did not affect ASMA or MEK/ERK. Cav-A increased collagen I expression in scleroderma lung fibroblasts. Full effects on fibroblasts of versions of CSD required 5 μM peptide. Conclusions Cav-BC retains most of the anti-fibrotic functions of CSD; Cav-A exhibits certain pro-fibrotic functions. Results obtained with subdomains and mutated versions of CSD further suggest that the critical functional residues in CSD depend on the cell type and readout being studied. Monocytes may be more sensitive to versions of CSD than fibroblasts and endothelial cells because the baseline level of caveolin-1 in monocytes is much lower than in these other cell types. PMID:24011378
Differential regulation of cell functions by CSD peptide subdomains.
Reese, Charles; Dyer, Shanice; Perry, Beth; Bonner, Michael; Oates, James; Hofbauer, Ann; Sessa, William; Bernatchez, Pascal; Visconti, Richard P; Zhang, Jing; Hatfield, Corey M; Silver, Richard M; Hoffman, Stanley; Tourkina, Elena
2013-09-08
In fibrotic lung diseases, expression of caveolin-1 is decreased in fibroblasts and monocytes. The effects of this deficiency are reversed by treating cells or animals with the caveolin-1 scaffolding domain peptide (CSD, amino acids 82-101 of caveolin-1) which compensates for the lack of caveolin-1. Here we compare the function of CSD subdomains (Cav-A, Cav-B, Cav-C, Cav-AB, and Cav-BC) and mutated versions of CSD (F92A and T90A/T91A/F92A). Migration toward the chemokine CXCL12 and the associated expression of F-actin, CXCR4, and pSmad 2/3 were studied in monocytes from healthy donors and SSc patients. Fibrocyte differentiation was studied using PBMC from healthy donors and SSc patients. Collagen I secretion and signaling were studied in fibroblasts derived from the lung tissue of healthy subjects and SSc patients. Cav-BC and CSD at concentrations as low as 0.01 μM inhibited the hypermigration of SSc monocytes and TGFβ-activated Normal monocytes and the differentiation into fibrocytes of SSc and Normal monocytes. While CSD also inhibited the migration of poorly migrating Normal monocytes, Cav-A (and other subdomains to a lesser extent) promoted the migration of Normal monocytes while inhibiting the hypermigration of TGFβ-activated Normal monocytes. The effects of versions of CSD on migration may be mediated in part via their effects on CXCR4, F-actin, and pSmad 2/3 expression. Cav-BC was as effective as CSD in inhibiting fibroblast collagen I and ASMA expression and MEK/ERK signaling. Cav-C and Cav-AB also inhibited collagen I expression, but in many cases did not affect ASMA or MEK/ERK. Cav-A increased collagen I expression in scleroderma lung fibroblasts. Full effects on fibroblasts of versions of CSD required 5 μM peptide. Cav-BC retains most of the anti-fibrotic functions of CSD; Cav-A exhibits certain pro-fibrotic functions. Results obtained with subdomains and mutated versions of CSD further suggest that the critical functional residues in CSD depend on the cell type and readout being studied. Monocytes may be more sensitive to versions of CSD than fibroblasts and endothelial cells because the baseline level of caveolin-1 in monocytes is much lower than in these other cell types.
Cardiopulmonary Syndromes (PDQ®)—Patient Version
Cardiopulmonary syndromes are conditions of the heart and lung and can occur in some cancers. They include shortness of breath (dyspnea), chronic cough, pleural and pericardial effusion, and superior vena cava syndrome. Learn more about these conditions in this expert-reviewed summary.
Dyspnea during Advanced Cancer
... to Cancer Off-Label Drug Use Access to Experimental Drugs Complementary & Alternative Medicine (CAM) CAM for Patients ... pressure on the heart. Treatment may be to control the symptoms of ... vena cava syndrome (SVCS) is a group of signs and symptoms that occur when the ...
Kraft, Christiane; Hecking, Carola; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit
2013-07-01
Inferior vena cava (IVC) thrombosis is rare, and data about the clinical presentation of patients are scarce. Therefore, we reviewed all cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described patients characteristics in terms of their clinical presentations in the acute setting of IVC thrombosis. From the MAISTHRO registry, which enrolled 1470 consecutive patients with documented histories of venous thromboembolism, we identified 60 patients (0,4 %; females 60 %) with IVC thrombosis and 888 patients (60.4 %; females 55 %) with isolated lower-extremity deep vein thrombosis (LE-DVT). The median age at the time of IVC thrombosis manifestation was 36.5 years (9 to 83). IVC thrombosis was the initial VTE event in 47 patients (78 %). In the majority of cases, IVC thrombosis extended to the lower-extremity veins, and both lower extremities were affected in 17 cases (28 %). The initial clinical symptom of IVC thrombosis was lower back or abdominal pain which preceded typical symptoms of LE-DVT in 29 (48 %) patients. Symptomatic pulmonary embolism was more frequently observed in IVC thrombosis patients when compared to a sex- and age-matched subgroup of LE-DVT patients, although the difference was not significant (27 % vs. 12 %; p = 0.064). Malignant disease was the only established VTE risk factor with a higher prevalence among IVC thrombosis patients than patients with isolated LE-DVT (27 % vs. 9 %; p = 0.015). Congenital IVC anomalies were identified in another eight IVC thrombosis patients (13 %). IVC thrombosis should be considered a differential diagnosis for inexplicable lower back or abdominal pain especially in young patients. Malignant disease and congenital IVC anomalies seem to be predisposing factors for thrombosis involving the inferior vena cava.
Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R
2015-10-01
Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.
Veronesi, Marco; Mancini, Elena; Salvati, Filippo; Santoro, Antonio
2011-01-01
A 67-year-old woman with end-stage renal disease (polycystic kidney disease) who had been on dialysis for 10 years came to our department for a second opinion about upper left arm edema homolateral to the arteriovenous fistula (AVF). Because of the suspicion of venous stenosis she had already been submitted to angiographic examination of the AVF which, however, did not show any occlusive process. In addition to the kidney problem, the clinical history included dilated cardiomyopathy, and 2 years earlier a biventricular implantable cardioverter defibrillator (ICD) had been placed. The patient had never had a central venous catheter (CVC). She presented a typical superior vena cava syndrome picture with arm, neck and hemifacial edema and superficial cutaneous venous reticulum. The venous pressure during extracoroporeal circulation was high and blood recirculation was documented. Angio-CT was performed to look for a compressive process in the chest, but this was excluded. We then performed a new trans-AVF angiography to study extensively the axillary-subclavian-superior vena cava district. At first, no stenosis or thrombosis was observed, but the presence of ICD and its leads (left-sided implanted) in the anonymous vein created obstacles to diagnosis. Repeated injections of contrast medium and focusing imaging on the leads route allowed us to highlight a venous stenosis in the anonymous vein. Transluminal angioplasty was successfully carried out during the same procedure. 1) In hemodialysis patients the appearance of signs of intrathoracic vein drainage obstacles is not always associated with previous CVC implantation; 2) in the hemodialysis patient, any device (PM, ICD) should be implanted contralaterally to the fistula arm in order to avoid the risk that a venous stenosis may cause AVF dysfunction.
Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsunaga, Tadao; Haga, Yoichi; Saiki, Yoshikatsu
2014-10-01
The aim of our study was to develop a novel monitoring system for spinal cord blood flow (SCBF) to test the efficacy of the SCBF sensor in an animal model. The sensor system consisted of 2 optical fibers, a pedestal for fiber fixation, and a mirror for the laser reflection and was incorporated into a cerebrospinal fluid drainage catheter. In vivo studies were performed in a swine model (n=10) to measure SCBF during spinal cord ischemia induced by clamping the descending thoracic aorta and supra-aortic neck vessels, when necessary. A temporary low cardiac output model was also created by inflow clamping of the inferior vena cava to analyze the quantitative changes in SCBF during this maneuver. The developed SCBF monitoring catheter placed intrathecally could detect SCBF in all the swine. The SCBF after aortic crossclamping at the fourth intercostal level exhibited diverse changes reproducibly among the swine, with a >25% reduction in SCBF in 5 pigs, an increase in 3, and no significant changes in 2. Consistent reductions were recorded during inferior vena cava occlusion. The mean SCBF decreased by 32% after inferior vena cava occlusion when the cardiac output had decreased by 27%. We have developed a novel SCBF sensor that could detect real-time changes in spinal cord perfusion in a swine model. The device holds promise to detect imminent ischemia or ensure acceptable blood perfusion in the spinal cord and could further enhance our understanding of spinal cord circulation. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Gatzoulis, M A; Shinebourne, E A; Redington, A N; Rigby, M L; Ho, S Y; Shore, D F
1995-02-01
To show that abnormal systemic venous channels in patients who undergo cavopulmonary anastomoses can become manifest and haemodynamically important only after surgery despite detailed preoperative investigation. Descriptive study of patients fulfilling the above criteria selected from hospital records over the past three years. A tertiary referral centre. Of the three cases identified, two were isomeric, one with left atrial isomerism and hemiazygos continuation of the inferior vena cava who underwent bilateral bidirectional Glenn anastomoses and one with right isomerism who underwent total cavopulmonary anastomosis. Case 3 had absent left atrioventricular connection with a hypoplastic left lung and underwent a classic right Glenn procedure. All three cases presented with progressive cyanosis in the early postoperative period. Postoperative angiography in case 1 showed a remnant of a left inferior vena cava draining to the atrium to have become grossly dilated causing cyanosis, which resolved after redirection of this vessel and of the hepatic veins into the right pulmonary artery with an intra-atrial baffle. Cyanosis in case 2 was caused by intra-hepatic shunting to a hepatic vein draining to the left of the intra-atrial baffle. The diagnosis was made at necropsy, being overlooked on postoperative angiography. Repeat angiography in case 3 showed progressive dilatation of a small left superior vena cava to coronary sinus. Test occlusion with a view to embolisation revealed hitherto an undemonstrated hemiazygos continuation of inferior caval to brachiocephalic vein. The patient underwent surgical ligation of these two venous channels. Despite appropriate investigation some "abnormal" venous pathways manifest themselves, dilate, and become haemodynamically important only after surgical cavopulmonary anastomoses. In the presence of early postoperative cyanosis "new" systemic venous collateral channels should be considered as a possible cause, which may require reintervention.
Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika
The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%)more » had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).« less
Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana
Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less
Oppermann, Marc; Padberg, Stephanie; Kayser, Angela; Weber-Schoendorfer, Corinna; Schaefer, Christof
2013-03-01
Angiotensin-II receptor 1 antagonists (AT₁-antagonists) may cause severe and even lethal fetopathy in late pregnancy. However, exposure still occurs in spite of warnings in package leaflets. This study aimed to assess the risk of fetopathy, the sensitive time window, and possible new symptoms in prospective as well as retrospective cases with AT₁-antagonist treatment during the second or third trimester of pregnancy. Patients were enrolled by the Berlin Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy between 1999 and 2011 through risk consultation. Symptoms defined as indicative of AT₁-antagonist fetopathy were: oligo-/anhydramnios, renal insufficiency, lung hypoplasia, joint contractures, skull hypoplasia and fetal/neonatal death. In 5/29 (17%) prospectively enrolled cases with AT₁-antagonist exposure beyond the first trimester oligo-/anhydramnios was diagnosed. Two infants showed additional symptoms of fetopathy. The risk is more than 30% if treatment continues beyond the 20th week of pregnancy. Oligo-/anhydramnios was reversible after AT₁-antagonist withdrawal. Among 16 retrospective case reports, three infants presented with a thrombosis of the inferior vena cava in the vicinity of the renal veins. Four out of 13 live births did not survive. Our survey suggests that the risk increases with duration of AT₁-antagonist treatment into late pregnancy and oligo-/anhydramnios may be reversible after AT₁-antagonist discontinuation. Thrombosis of inferior vena cava may be a new feature of AT₁-antagonist fetopathy. AT₁-antagonist medication during pregnancy constitutes a considerable risk and must be discontinued immediately. In case of indicative diagnostic findings in either the fetus or newborn, previous maternal AT₁-antagonist exposure should be considered. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.
Rioja Zuazu, J; Rodríguez-Rubio Cortadillas, F; Zudaire Bergera, J J; Saiz Sansi, A; Rosell Costa, D; Robles García, J E; Rábago, G; Berián Polo, J M
2008-04-01
We present our 20 years experience treating patients with vena cava extension in whom an extracorporeal circulation, hypothermia, cardio circulatory arrest (ECC-H-CCA) in order to perform, together with a tumoral resection, a thrombus resection. From 1985 to 2005 a total of 28 retroperitoneal tumor were treated: 25 renal cancers, a Wilms tumor, a paratesticular rabdomiosarcoma, and a pheocromocitoma. All of them had an extension by means of thrombus above the suprahepatics veins. All of them were treated by means of ECC-H-CCA for thrombus extraction. A descriptive study of the serie is performed as well as a Kaplan Meyer survival study. Surgical complications were present within 10 patients (35%), with a surgical mortality of two patients (7%): one intra-operatively because a massive embolism of the lungs and the other because of a lung embolism on the 4th post-operative day. Global actuarial survival was 29.1+/-10% at three years and 17.5+/-8% at five years. Analyzing only who do not have metastatic lesions, nor lymph nodes at diagnosis their three year survival was 50.9+/-16.3% and 32.2+/-16% at five years. Mean while those who have any metastatic lesion at diagnosis their three and five years survival was 20.8+/-12% and 10.4+/-9% respectively. The employ of surgical techniques with ECC-H-CCA with in oncological pathology associated with vena cava thrombus is justified and its employment does not worsen the survival; it is indicated because its results, allowing a complete tumoral resection in a safe and reproducible fashion.
Ruiz-Delgado, Ana; Arrebola-Liébanas, Francisco Javier; Romero-González, Roberto; López-Ruiz, Rosalía; Garrido Frenich, Antonia
2016-10-01
A highly sensitive analytical method was developed to determine 2,4,6-trichloroanisole (TCA), 2,3,4,6-tetrachloroanisole (TeCA), 2,4,6-tribromoanisole (TBA) and 2,3,4,5,6-pentachloroanisole (PCA) in sparkling alcoholic beverages. The method was based on the use of headspace solid-phase microextraction (HS-SPME) using a polydimethylsiloxane (PDMS) fibre. It was coupled to gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) for the detection and quantification of the target haloanisoles. The method was fully automated and no sample preparation was needed. The method was validated for alcoholic beverages. The influence of CO 2 on the extraction efficiency was also evaluated for the studied sparkling drinks (cava and cider). All the calibration curves showed good linearity (R 2 > 0.98) within the tested range (1-50 ng l -1 ). Recoveries were evaluated at three different levels (1, 5 and 50 ng l -1 ) and were always between 71% and 119%. Precision was expressed as relative standard deviation (RSD), and was evaluated as intra- and inter-day precisions, with values ≤ 22% in both cases. Limits of quantitation (LOQs) were ≤ 0.91 ng l -1 , which are below the sensory threshold levels for such compounds in humans. The validated method was applied to commercial samples, 10 cavas and 10 ciders, but it was also used for the analysis of nine red wines and four white wines, demonstrating the further applicability of the proposed method to non-sparkling beverages. TCA was detected in most samples at up to 0.45 ng l -1 .
Effects of Ecklonia cava polyphenol in individuals with hypercholesterolemia: a pilot study.
Lee, Dong Hyeon; Park, Mi Yeon; Shim, Byung Joo; Youn, Ho Joong; Hwang, Hye Jeong; Shin, Hyeon Cheol; Jeon, Hui Kyung
2012-11-01
We evaluated the efficacy and safety of Ecklonia cava polyphenol (Seapolynol™, a polyphenol antioxidant and anti-inflammatory agent purified from E. cava) during a 12-week treatment period (400 mg orally once daily) in individuals with hypercholesterolemia and performed subgroup analysis for metabolic syndrome (MetS). As a noncomparative study, forty-six individuals (M:F=22:24, mean age=54±11 years) with fasting total cholesterol concentration >240 mg/dL or low-density lipoprotein cholesterol (LDL-C) concentration >130 mg/dL were enrolled. Hip circumference (100±7 cm vs. 98±7 cm, P<.01), total cholesterol (244±25 mg/dL vs. 225±37 mg/dL, P<.01), LDL-C (161±24 mg/dL vs. 146±34 mg/dL, P<.01), and C-reactive protein (2.51±3.55 mg/L vs. 1.37±1.32 mg/L, P<.05) were significantly decreased without significant adverse effect. A differential assessment according to the presence [MetS(+) group, n=18] and absence [MetS(-) group, n=28] of MetS showed that Hb(A1c) decreased significantly following 12-week Seapolynol treatment in the MetS(+) compared with the MetS(-) group (-0.3%±0.5% vs. 0.1%±0.3%, P<.01). In conclusion, although our results showed that Seapolynol treatment is effective and safe without significant adverse events or abnormal laboratory findings during a 12-week period in individuals with hypercholesterolemia, more research in a larger population with a longer-term follow-up period in a randomized placebo-controlled study is needed to confirm the results.
Abnormal gel flotation caused by contrast media during adrenal vein sampling
Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Gelati, Matteo; Bassi, Antonella; Contro, Alberto; Pizzolo, Francesca; Guidi, Gian Cesare
2016-01-01
Introduction During adrenal venous sampling (AVS) procedure, radiologists administer a contrast agent via the catheter to visualize the proper catheter position. Materials and methods A patient with primary aldosteronism diagnostic-hypothesis was admitted for AVS. A venogram was performed to confirm the catheter’s position with 2mL of Iopamidol 300 mg/mL. Samples were collected with syringe connected to a hydrophilic coated catheter by low-pressure aspiration from each of the four collection sites: inferior vena cava in the suprarenal portion, inferior vena cava in the infrarenal portion, left adrenal vein, and right adrenal vein; then immediately transferred from syringe to tubes with gel separator. All tubes were centrifuged at 1200 x g for 10 minutes. Results At the end of centrifugation process, primary blood tubes containing blood from inferior vena cava and left adrenal vein exhibited the standard gel separator barrier, while tubes from right adrenal vein showed abnormal flotation of gel separator. The radiologist confirmed the usage of 2.6 mL instead of 2.0 mL of Iopamidol 300 mg/mL. This iodinated contrast media, with 1.33 g/cm3 of density, was used close to the right adrenal vein due to some difficulty to access it. Conclusion The abnormal flotation of gel separator in samples taken from right adrenal vein can be explained by the usage of the iodinated contrast media. We suggest using plain-tubes (without gel separator) for AVS in order to avoid preanalytical nonconformities. Moreover, a blood volume equivalent to twice the catheter extension should be discarded to eliminate residual contrast media before collection of samples for laboratory assays. PMID:27812311
Loudin, Michael; Anderson, Sharon; Schlansky, Barry
2016-10-24
Proximal or 'downhill' esophageal varices are a rare cause of upper gastrointestinal hemorrhage. Unlike the much more common distal esophageal varices, which are most commonly a result of portal hypertension, downhill esophageal varices result from vascular obstruction of the superior vena cava (SVC). While SVC obstruction is most commonly secondary to malignant causes, our review of the literature suggests that benign causes of SVC obstruction are the most common cause actual bleeding from downhill varices. Given the alternative pathophysiology of downhill varices, they require a unique approach to management. Variceal band ligation may be used to temporize acute variceal bleeding, and should be applied on the proximal end of the varix. Relief of the underlying SVC obstruction is the cornerstone of definitive treatment of downhill varices. A young woman with a benign superior vena cava stenosis due to a tunneled internal jugular vein dialysis catheter presented with hematemesis and melena. Urgent upper endoscopy revealed multiple 'downhill' esophageal varices with stigmata of recent hemorrhage. As there was no active bleeding, no endoscopic intervention was performed. CT angiography demonstrated stenosis of the SVC surrounding the distal tip of her indwelling hemodialysis catheter. The patient underwent balloon angioplasty of the stenotic SVC segment with resolution of her bleeding and clinical stabilization. Downhill esophageal varices are a distinct entity from the more common distal esophageal varices. Endoscopic therapies have a role in temporizing active variceal bleeding, but relief of the underlying SVC obstruction is the cornerstone of treatment and should be pursued as rapidly as possible. It is unknown why benign, as opposed to malignant, causes of SVC obstruction result in bleeding from downhill varices at such a high rate, despite being a less common etiology of SVC obstruction.
Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli
2016-02-01
Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.
Puerperal ovarian vein thrombosis: two case reports.
Angelini, Marta; Barillari, Giovanni; Londero, Ambrogio P; Bertozzi, Serena; Bernardi, Sergio; Petri, Roberto; Driul, Lorenza; Marchesoni, Diego
2013-02-01
Ovarian vein thrombosis (OVT) is an uncommon but potentially serious complication in the early postpartum. Two case studies seem to prove the point: Case 1 A 24-year-old woman was transferred to our hospital with the chief complaint of abdominal pain radiating to the right thigh, vomit, diarrhea, and a slight pyrexia (37.6 °C rectal). Five days earlier, she had a spontaneous vaginal delivery after labor induction. The woman appeared slightly distressed because of pain; vital signs were found to be normal and the CRP elevated (129.9 mg/L). Abdominal examination was remarkable for tenderness by palpation in the right lower quadrant with no rebound tenderness or guarding. Pelvic examination was remarkable for mild right adnexal tenderness. Abdominal-pelvic computer tomography with contrast medium revealed a 2.5-cm OVT having extended into the inferior vena cava for 14 cm with a slight peripheral edema. The patient was treated with nadroparin 0.6 cc (5700 IU) bid and warfarin 5 mg since the attainment of the therapeutic INR range. Case 2 A 31-year-old twin-pregnant woman had an emergency cesarean section at 35 gestational weeks because of hypertension complicated by increased liver enzymes, diuresis contraction, and continuous lower back pain bilaterally radiating to the groins. One day after delivery, CT scan that was performed because of onward anemia showed a pelvic, perihepatic, and perisplenic blood effusion, and a 1-cm right OVT extended to the inferior vena cava below renal veins for 28 mm. She underwent exploratory laparotomy and blood transfusion, and because of respiratory insufficiency she was transferred to a second level center with ICU facility, where she was placed under a suprarenal inferior vena cava filter, and AngioJet Rheolytic Thrombectomy for acute pulmonary embolism was performed.
SvO2 Trigger in Transfusion Strategy After Cardiac Surgery
2018-03-27
Undergoing Nonemergent Cardiac Surgery; Central Venous Catheter on the Superior Vena Cava (to Perform ScVO2 Measure); Anemia (<9g/dL) Requiring Blood Transfusion; Hemodynamic and Respiratory Stability; Bleeding Graded as Insignificant, Mild, Moderate of Universal Definition of Perioperative Bleeding
Three-Dimensional Reconstruction of Thoracic Structures: Based on Chinese Visible Human
Luo, Na; Tan, Liwen; Fang, Binji; Li, Ying; Xie, Bing; Liu, Kaijun; Chu, Chun; Li, Min
2013-01-01
We managed to establish three-dimensional digitized visible model of human thoracic structures and to provide morphological data for imaging diagnosis and thoracic and cardiovascular surgery. With Photoshop software, the contour line of lungs and mediastinal structures including heart, aorta and its ramus, azygos vein, superior vena cava, inferior vena cava, thymus, esophagus, diaphragm, phrenic nerve, vagus nerve, sympathetic trunk, thoracic vertebrae, sternum, thoracic duct, and so forth were segmented from the Chinese Visible Human (CVH)-1 data set. The contour data set of segmented thoracic structures was imported to Amira software and 3D thorax models were reconstructed via surface rendering and volume rendering. With Amira software, surface rendering reconstructed model of thoracic organs and its volume rendering reconstructed model were 3D reconstructed and can be displayed together clearly and accurately. It provides a learning tool of interpreting human thoracic anatomy and virtual thoracic and cardiovascular surgery for medical students and junior surgeons. PMID:24369489
Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data
Molvar, Christopher
2012-01-01
Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414
Ennaifer, Rym; B'chir Hamzaoui, Saloua; Larbi, Thara; Romdhane, Hayfa; Abdallah, Maya; Bel Hadj, Najet; M'rad, Sander
2015-03-01
Behçet's disease (BD) is a multisystemic disorder that involves vessels of all sizes. Superior vena cava (SVC) thrombosis is a rare complication that can lead to the development of various collateral pathways. A 31-year-old man presented with SVC syndrome. He had a history of recurrent genital aphthosis. Computed tomography revealed extensive thrombosis of the right internal jugular, axillary, and subclavian veins with collateral circulation. The patient was diagnosed with BD, and he was started on anticoagulation and immunosuppressive therapy. One week later, he presented with haematemesis. Upper gastrointestinal endoscopy disclosed varices in the upper third of the oesophagus with stigmata of recent bleeding. Portal hypertension was ruled out. Anticoagulation therapy was discontinued. He was discharged on immunosuppressive therapy. Bleeding from downhill oesophageal varices should be suspected in any patient presenting with upper gastrointestinal bleeding and a history of SVC syndrome due to BD. Copyright © 2015 Arab Journal of Gastroenterology. Published by Elsevier B.V. All rights reserved.
Complications of inferior vena cava filters
Grewal, Simer; Chamarthy, Murthy R.
2016-01-01
Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983
Morphology of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats.
White, R N; Parry, A T
2013-09-01
To describe the anatomy of congenital portosystemic shunts emanating from the left gastric vein in dogs and cats. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Forty-six dogs and 27 cats met the inclusion criteria of a congenital portosystemic shunt emanating from the left gastric vein. Of the 46 dogs, 28 (61%) had a shunt that entered the left phrenic vein, 10 (22%) had a shunt that entered the post hepatic caudal vena cava and in 8 (17%) the shunt entered the azygos vein. Of the 27 cats, 19 (70%) had a shunt that entered the left phrenic vein and 8 (30%) had a shunt that entered the post hepatic caudal vena cava. The systemic vein into which the shunt entered was consistent showing three common presentations: left gastro-phrenic, left gastro-caval and left gastro-azygos. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2013 British Small Animal Veterinary Association.
Successful laparoscopic division of a patent ductus venosus: report of a case.
Hara, Yoshiaki; Sato, Yoshinobu; Yamamoto, Satoshi; Oya, Hiroshi; Igarashi, Masato; Abe, Satoshi; Kokai, Hidenaka; Miura, Kohei; Suda, Takeshi; Nomoto, Minoru; Aoyagi, Yutaka; Hatakeyama, Katsuyoshi
2013-04-01
Patent ductus venosus (PDV) is a rare condition of a congenital portosystemic shunt from the umbilical vein to the inferior vena cava. This report presents the case of an adult patient with PDV, who was successfully treated with laparoscopic shunt division. A 69-year-old male was referred with hepatic encephalopathy. Contrast-enhanced CT revealed a large connection between the left portal vein and the inferior vena cava, which was diagnosed as PDV. The safety of a shunt disconnection was confirmed using a temporary balloon occlusion test for the shunt, and the shunt division was performed laparoscopically. The shunt was carefully separated from the liver parenchyma with relative ease, and then divided using a vascular stapler. Portal flow was markedly increased after the operation, and the liver function of the patient improved over the 3-month period after surgery. Although careful interventional evaluation for portal flow is absolutely imperative prior to surgery, a minimally invasive laparoscopic approach can be safely used for treating PDV.
PROTEIN METABOLISM AND EXCHANGE AS INFLUENCED BY CONSTRICTION OF THE VENA CAVA
McKee, Frank W.; Schloerb, Paul R.; Schilling, John A.; Tishkoff, Garson H.; Whipple, George H.
1948-01-01
Constriction of inferior vena cava above the diaphragm is used to produce experimental ascites in the dog. This type of experimental ascites drains the body protein reserves, reduces the level of circulating plasma proteins, and in effect is an internal plasmapheresis. As the ascitic fluid is withdrawn and the proteins measured, we observe a production of ascitic protein (80–90 gm. per week) comparable to that removed by plasmapheresis (bleeding and replacement of red cells in saline). High protein diet tends to decrease the ascites but the protein content of the ascitic fluid may increase. Sodium chloride increases notably the volume of the ascites which accumulates and the total ascitic protein output increases. Sodium-free salt mixtures have a negative influence. High protein diet low in sodium salts gives minimal ascitic accumulation under these conditions. The question of circulation of the ascitic fluid is raised—how rapid is the absorption and the related accumulation? PMID:18858638
Lluis Pons, Laia; Chahri Vizcarro, Nadia; Llaverias Borrell, Silvia; Miquel Abbad, Carlos
2017-06-01
Splenoportal axis thrombosis not associated with cirrhosis or neoplasms has a prevalence lower than 5 per 10,000 people. An etiologic factor responsible for portal thrombosis is finally identified in most cases, usually systemic thrombogenic factors or predisposing local factors. However, despite a detailed study of all etiologic factors, up to 30% of cases are eventually considered as idiopathic in origin. We report the case of a 41-year-old patient who presented with abdominal pain and lower extremity edema. The patient was diagnosed with portal and mesenteric-portal confluence thrombosis, bilateral deep venous thrombosis and right lumbar vein thrombosis based on an abdominal CT scan. This was associated with a likely congenital inferior vena cava agenesis. This malformation is present in approximately 5% of patients with deep vein thrombosis even though it represents a rare cause of portal thrombosis. The fact that several thromboses developed simultaneously makes this a unique and isolated case in the current literature as no similar cases have been reported thus far.
Patterson, K.A.; Zhang, X.; Wrobleski, S.K.; Hawley, A.E.; Lawrence, D. A.; Wakefield, T.W.; Myers, D.D.; Diaz, J.A.
2013-01-01
Introduction Statins, particularly rosuvastatin, have recently become relevant in the setting of venous thrombosis. The objective of this study was to study the non-lipid lowering effects of rosuvastatin in venous thrombosis in mice with hyperlipidemia. Materials and Methods An inferior vena cava ligation model of venous thrombosis in mice was utilized. Saline or 5mg/kg of rosuvastatin was administered by gavage 48hs previous thrombosis. Blood, the inferior vena cava, thrombus, and liver were harvested 3, 6 hours, and 2 days post-thrombosis. Thrombus weight, inflammatory markers, and plasminogen activator inhibitor-1 expression and plasma levels were measured and neutrophil migration to the IVC was assessed. Results Rosuvastatin significantly decreased thrombus weight, plasminogen activator inhibitor-1 expression and plasma levels, expression of molecules related to the interleukin-6 pathway, and neutrophil migration into the vein wall. Conclusions This work supports the beneficial effects of rosuvastatin on venous thrombosis in mice with hyperlipidemia due to its non-lipid lowering effects. PMID:23276528
KAWAKAMI, MANRI; KODA, MASAHIKO; MANDAI, MARI; HOSHO, KEIKO; MURAWAKI, YOSHIKAZU; ODA, WAKAKO; HAYASHI, KAZUHIKO
2013-01-01
The aim of this study was to clarify the clinical features of patients with isolated HCC metastases to the heart. A 66-year-old female hospitalized with a hepatocellular carcinoma (HCC) ranging from the right to the left lobe and with a tumor thrombus in the main portal vein, was treated with intraarterial cisplatin, 5-fluouracil, adriamycin and mitomycin. Computed tomography (CT) one month later revealed that the HCC had progressed with multiple lung metastases and moderate ascites. The patient had no symptoms. Magnetic resonance imaging (MRI) and echocardiography revealed a round, movable tumor with a diameter of 2 cm in the right atrium (RA). The patient succumbed to HCC five months later. An autopsy revealed HCC with portal tumor thrombi and metastases to the lungs, inferior vena cava (IVC) and RA. The metastases in the RA and IVC were not continous with the intrahepatic tumor and were histologically attached to the endocardium and endothelium, respectively. An isolated metastasis of a HCC of the RA and IVC is extremely rare. In conclusion, although the majority of isolated metastases of HCC to the heart were diagnosed by echocardiography and were treated with mainly surgery, they had poor prognosis. The echocardiography should be performed for patients with advanced HCC. A novel treatment including molecular targeted drugs is required. PMID:23760591
Bleeding Duodenal: Varices Treatment by TIPS and Transcatheter Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopera, Jorge E.; Arthurs, Blain; Scheuerman, Christian
2008-03-15
We describe our clinical experience in 4 patients with portal hypertension who presented with bleeding mesenteric varices originating from the superior mesenteric vein with retrograde filling of collaterals draining into the inferior vena cava. The clinical presentation, imaging findings, and potential therapeutic management are discussed.
Constraints from Water on Mantle Melting and Slab Fluid Composition
NASA Astrophysics Data System (ADS)
Plank, T.; Wade, J.
2005-12-01
Water drives mantle melting and fluid migration in subduction zones, but most models for these phenomena have been developed without constraints from water measurements in arc magmas. For example, the Central American volcanic arc (CAVA) records systematic variations in La/Yb, Ba/La and d18O, and these proxies have been used to predict the extent of mantle melting during decompression [1] and water-addition [2]. Here we use water concentrations in olivine-hosted melt inclusions from arc tephra, along with estimates derived from a clinopyroxene hygrometer [3], to test different models for mantle melting and slab fluid composition along the CAVA (from Nicaragua to Costa Rica). We use Ti as a proxy for mantle melt fraction (F) and invert H2O concentrations in CAVA magmas to obtain those in the mantle source (H2Oo), as in [4]. The relationship between F and H2Oo is nominally linear for Costa Rica mantle, with wet melting productivity dF/dH2O = 30 (wt%/wt%), higher than that used in [2], but consistent with experimentally-determined and MELTS-calculated productivity at 50 degrees above the dry solidus. This predicts mantle temperature beneath Costa Rica of at least 1350°C, and allows for a small (1-2% F) decompression-melting contribution, relative to the wet melting contribution (8-20% F). The percent of wet melting correlates locally with Ba/La, but not regionally, and so the use of Ba/La as a wet melting proxy [1] should be limited to single volcanoes or clusters. The water content of the CAVA melting region varies from 2500-9000 ppm H2O but does not decrease monotonically from Nicaragua to Costa Rica as does Ba/La. The relationship between H2Oo and Ba/La is thus complex, and requires a large along-strike decrease in Ba/La and H2O/La in the slab fluids towards the southeast. Such variation appears to be driven largely by La concentration, reflecting more dilute fluids (higher H2O/La) beneath Nicaragua and more solute-rich fluids (e.g., sediment melts with high La/ H2O) beneath Costa Rica. [1] Walker, J.A., M.J. Carr, L.C. Patino, C.M. Johnson, M.D. Feigenson, R.L. Ward Contrib. Mineral. Petrol. [2] Eiler, J.M., M.J. Carr, M. Reagan, E. Stolper, 2005. Geochem. Geophys. Geosyst. [3] Plank, T., Benjamin, E., Wade, J., Grove, T.L. 2004. Fall Mtg, AGU. [4] Kelley, K., Plank, T., Newman, S., Stolper, E.M., Grove, TL, Hauri, E. 2005. JGR.
Sperry, Brett W; Vranian, Michael N; Hachamovitch, Rory; Joshi, Hariom; McCarthy, Meghann; Ikram, Asad; Hanna, Mazen
2016-07-01
Low voltage electrocardiography (ECG) coupled with increased ventricular wall thickness is the hallmark of cardiac amyloidosis. However, patient characteristics influencing voltage in the general population, including bundle branch block, have not been evaluated in amyloid heart disease. A retrospective analysis was performed of patients with newly diagnosed cardiac amyloidosis from 2002 to 2014. ECG voltage was calculated using limb (sum of QRS complex in leads I, II and III) and precordial (Sokolow: S in V1 plus R in V5-V6) criteria. The associations between voltage and clinical variables were tested using multivariable linear regression. A Cox model assessed the association of voltage with mortality. In 389 subjects (transthyretin ATTR 186, light chain AL 203), 30% had conduction delay (QRS >120ms). In those with narrow QRS, 68% met low limb, 72% low Sokolow and 57% both criteria, with lower voltages found in AL vs ATTR. LV mass index as well as other typical factors that impact voltage (age, sex, race, hypertension, BSA, and smoking) in the general population were not associated with voltage in this cardiac amyloidosis cohort. Patients with LBBB and IVCD had similar voltages when compared to those with narrow QRS. Voltage was significantly associated with mortality (p<0.001 for both criteria) after multivariable adjustment. Classic predictors of ECG voltage in the general population are not valid in cardiac amyloidosis. In this cohort, the prevalence estimates of ventricular conduction delay and low voltage are higher than previously reported. Voltage predicts mortality after multivariable adjustment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Which echocardiographic parameter is a better marker of volume status in hemodialysis patients?
Sabaghian, Tahereh; Hajibaratali, Bahareh; Samavat, Shiva
2016-11-01
Bio-impedance analysis (BIA) is a preferred method for estimating the volume status. However, it cannot be utilized in daily practice. Since the assessment of the volume status is important and challenging for hemodialysis (HD) patients, the aim of study was to determine the volume status in chronic HD patients using echocardiographic parameters and assess its correlation with BIA. In this cross-sectional analysis, echocardiography and BIA were performed on 30 chronic HD patients 30 min before and 30 min after dialysis. All the cases of dialysis were performed in the middle of the week. This study also assessed the correlation between echocardiographic parameters and BIA parameters. There were significant differences between ECW, TBW, and TBW% (TBW/W) before and after HD. Significant differences were observed between echocardiographic parameters of IVCD, IVCDi min , IVCDi max before and after the HD. LVEDD, LVESD, LA area, mitral valve inflow, E/E', and IVRT, were improved after dialysis, too. There was a significant correlation between IVCDi min as an index of volume status, ECW% and TBW% before HD and IVCDi min change after dialysis had a significant correlation with %ECW change after dialysis. Comparison between hypertensive and non-hypertensive groups indicated IVCDi min was significantly lower in non-hypertensive group after dialysis. Our results showed a correlation between IVCDi min and BIA parameters before HD. So, it seems that IVCDi min can be a good parameter for determining the volume status of HD patients. However, further studies, with larger sample size and with a prospective study design, are required to confirm these results.
Perforation of the heart by an inferior vena cava filter.
Bolton, J W; Aldea, G S
1994-04-01
The use of vena caval filters to prevent pulmonary emboli has become routine. Although the complications have been well described, we present the first reported case of perforation of the heart and subsequent cardiac tamponade several months following placement of a Gintureo-Roehm "bird's nest" filter.
Gerlach, Trevor J; de Wit, Martine; Landolfi, Jennifer A
2012-10-01
Postmortem evaluation of a Florida manatee (Trichechus manatus latirostris) revealed cold stress lesions and previous watercraft trauma that included broken ribs, a diaphragmatic hernia, an enlarged vena cava, and right-sided cardiomegaly. We discuss these findings and present a possible pathogenesis for the cardiomegaly.
Astarcıoğlu, Mehmet Ali; Yaymacı, Mehmet; Şen, Taner; Kilit, Celal; Amasyalı, Basri
2015-10-01
Arrhythmogenic right ventricular cardiomyopathy (ARVC) is an inherited cardiomyopathy characterized histologically by fibro-fatty replacement of heart muscle, and clinically by ventricular arrhythmias and right ventricular dysfunction. This report presents monozygotic twins with ARVC, suggesting a genetic abnormality as the most probable cause.
Characterization of Human Torso Vascular Morphometry in Normotensive and Hypotensive Trauma Patients
2015-07-01
Aorta Wall Measures Merged for Analysis Landmarks & User-aided Segmentation 5cm Volume...with Centerline Measures AORTA PROCESSING VENA CAVA PROCESSING Basic Morphomics Scan Identification Aorta Centerline Segmented Aorta and Vena...Analysis 49 Data Presentation Aorta Radius Popula/on Normotensive Hypotensive
Total anomalous systemic with partial anomalous pulmonary venous connections.
Vallath, Gopakumar; Gajjar, Trushar; Desai, Neelam
2013-12-01
A 9-year-old girl with cyanosis, dyspnea, and grade II clubbing was diagnosed by contrast transthoracic echocardiography and angiocardiography to have an anomalous connection of the venae cavae to the physiologic left atrium with partial anomalous pulmonary venous connection. Successful surgical correction was achieved, and the patient's recovery was uneventful.
Thromboembolic diseases and the use of vena cava filters.
De Silva, Samanthi
2017-04-01
Mr GW is a 77-year-old gentleman who is hoping to have a total knee replacement of his left knee. He underwent a knee replacement on the right in 2011 under spinal anaesthetic, where his postoperative period was complicated by a saddle pulmonary embolus (PE). Copyright the Association for Perioperative Practice.
Braile Vena Cava Filter and Greenfield Filter in Terms of Centralization
de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon
2013-01-01
The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter’s symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry. PMID:23459189
Braile vena cava filter and greenfield filter in terms of centralization.
de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon
2013-01-01
The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.
Cement pulmonary embolism after vertebroplasty.
Sifuentes Giraldo, Walter Alberto; Lamúa Riazuelo, José Ramón; Gallego Rivera, José Ignacio; Vázquez Díaz, Mónica
2013-01-01
In recent years, the use of vertebral cementing techniques for vertebroplasty and kyphoplasty has spread for the treatment of pain associated with osteoporotic vertebral compression fractures. This is also associated with the increased incidence of complications related with these procedures, the most frequent being originated by leakage of cementation material. Cement can escape into the vertebral venous system and reach the pulmonary circulation through the azygous system and cava vein, producing a cement embolism. This is a frequent complication, occurring in up to 26% of patients undergoing vertebroplasty but, since most patients have no clinical or hemodynamical repercussion, this event usually goes unnoticed. However, some serious, and even fatal cases, have been reported. We report the case of a 74-year-old male patient who underwent vertebroplasty for persistent pain associated with osteoporotic L3 vertebral fracture and who developed a cement leak into the cava vein and right pulmonary artery during the procedure. Although he developed a pulmonary cement embolism, the patient remained asymptomatic and did not present complications during follow-up. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Disha, Bansal; Prakashini, Koteshwara; Shetty, Ranjan K
2014-01-01
The most common venous abnormality of the thorax is persistent left superior vena cava (PLSVC), incidence being less than 0.5%. However, with congenital heart disease, it is about 6.1%. When the coronary sinus is dilated always search for PLSVC. The coronary sinus may communicate with the left atrium. This is known as an unroofed coronary sinus (UCS) and preoperatively documenting it is important. Of all the congenital cardiac anomalies, the sinus venosus defect (SVD) type of atrial septal defect (ASD) is most commonly associated with PLSVC and accounts for 4–11% of all ASDs. Multidetector CT can easily show all these abnormalities along with haemodynamics. On transoesophageal echocardiography it is difficult to characterise SVD and visualise a coronary sinus because of a limited window, contrast resolution and poor patient compliance. The complex of UCS and PLSVC is one such abnormality and its treatment requires careful assessment of other concomitant cardiac abnormalities to prevent post-treatment haemodynamic complications. PMID:24850552
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juszkat, Robert, E-mail: radiologiamim@wp.p; Pukacki, Fryderyk; Zarzecka, Anna
We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The proceduremore » was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.« less
Wiebe, Jens; Rixe, Johannes; Nef, Holger
2015-10-01
A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.
Accessory hepatic vein complicating extra-cardiac total cavopulmonary connection.
Yoshii, Shinpei; Suzuki, Shoji; Osawa, Hiroshi; Hosaka, Shigeru; Honda, Yoshihiro; Abraham, Samuel J K; Tada, Yusuke; Sugiyama, Hisashi; Tan, Tetsushi; Kadono, Toshie; Hoshiai, Minako; Komai, Takayuki
2002-04-01
We encountered unexpected, severe hypoxia after the right heart bypass operation in a patient with isomerism. A 2-year-old girl with polysplenia had a complex cardiac anomaly consisting of a single atrium, single ventricle, pulmonary stenosis, absence of the right superior vena cava, hemiazygos continuation of the left inferior vena cava, and d-malposition of the great arteries. After a total cavopulmonary shunt, we performed an extra-cardiac total cavo-pulmonary connection with a 14 mm tube graft. The postoperative course was complicated by severe hypoxia. Angiography performed 20 days after the operation showed that contrast medium in the conduit poured into the hepatic vein, and through the intrahepatic communications, it passed into a left-sided accessory hepatic vein, which was connected directly to the left side of the aspect of the atrium. As the intrahepatic communication was adequate, we ligated the accessory hepatic vein within the pericardial cavity. The SpO2 returned to normal and no hepatic dysfunction was detected. We conclude that surgeons performing extra-cardiac total cavopulmonary connection need to pay closer attention to the possibility that an accessory hepatic vein might exist.
Histology of Tissue Adherent to OptEase Inferior Vena Cava Filters Regarding Indwelling Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Volkov, Alexander; Garniek, Alexander
The purpose of this paper is to report on the histology of tissues found on retrieved filters with regard to indwelling time. Between February 2006 and January 2007, 28 Optease inferior vena cava filters (Cordis Europa, Roden, The Netherlands) were retrieved from 27 patients. Twenty-two filters were inserted prophylactically for trauma patients and six for patients with venous thromboembolism. Cavography was performed both before and after filter removal to evaluate the presence of thrombi or wall damage. Filters were retrieved with the snare and sheath method. All material adherents to the filters were examined histologically.The mean indwelling time of themore » filters was 24.9 days (range, 6-69 days). Red tissue fragments were seen on all the filters, consistent microscopically with clots and fibrin. On five filters (18%; mean indwelling time, 45.4 days) white tissue consistent with vascular intima was found. All postprocedure cavographies were normal. We conclude that most material adherent to the retrieved filters is thrombi, while vascular intima can be found in the minority of filters with a longer indwelling time.« less
Mediastinal germ cell tumour causing superior vena cava tumour thrombosis.
Karanth, Suman S; Vaid, Ashok K; Batra, Sandeep; Sharma, Devender
2015-03-25
We report a rare case of a 35-year-old man who presented with a 1-week history of retrosternal chest pain of moderate intensity. A positron emission tomography CT (PET-CT) showed a large fluorodeoxy-glucose (FDG)-avid heterogeneously enhancing necrotic mass in the anterosuperior mediastinum with a focal FDG-avid thrombosis of the superior vena cava (SVC) suggestive of tumour thrombus and vascular invasion. α-Fetoprotein levels were raised (5690 IU/L). Image guided biopsy of the mediastinal mass was suggestive of non-seminomatous germ cell tumour (NSGCT). The patient received four cycles of BEP (bleomycin, etoposide and cisplatin) along with therapeutic anticoagulation with low-molecular-weight heparin. Follow-up whole body PET-CT revealed complete resolution of mediastinal mass and SVC tumour thrombosis. The documentation of FDG-PET-avid tumour thrombus resolving with chemotherapy supports the concept of circulating tumour cells being important not only in common solid tumours such as breast and colon cancer but also in relatively less common tumours such as NSGCT. The detection of circulating tumour cells could help deploy aggressive regimens upfront. 2015 BMJ Publishing Group Ltd.
Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.
Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H
1996-03-01
The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.
Amin, Parth; Sharafuddin, Mel J; Laurich, Chad; Nicholson, Rachael M; Sun, Raphael C; Roh, Simon; Kresowik, Timothy F; Sharp, William J
2012-02-01
This article presents the case of a 42-year-old man who presented with superior vena cava (SVC) syndrome due to fibrosing mediastinitis with multiple failed attempts at recanalization. We initially treated him with unilateral sharp needle recanalization of the right innominate vein into the SVC stump followed by stenting. Although his symptoms improved immediately, they did not completely resolve. Six months later, he returned with worsening symptoms, and venography revealed in-stent restenosis. The patient requested simultaneous treatment on the left side. The right stent was dilated, and a 3-cm-long occlusion of the left innominate vein was recanalized, again using sharp needle technique, homing into the struts of the right-sided stent. Following fenestration of the stent, a second stent was deployed from the left side into the SVC, and the two Y limbs were sequentially dilated to allow a true bifurcation anatomy (figure). The patient had complete resolution of his symptoms and continues to do well 6 months later. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.
Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki
2014-02-01
Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Park, Jin-Sung; Kim, Jaedong; Lee, Yonggu; Gwon, Jun-Gyo; Park, Ye-Soo
2018-05-07
Percutaneous vertebroplasty (PVP) is a minimally invasive surgical treatment for patients with osteoporotic vertebral compression fracture (OVCF) and can rapidly alleviate pain, improve mobility, and stabilize the vertebrae. However, it has the potential to cause complications such as cement embolism. A 55-year-old female presented with pain in the lumbar region as a chief complaint. PVP was performed after diagnosis of acute OVCFs at L4 and L5. No abnormal symptoms were reported after surgery, but a large cement embolism was observed in her right atrium and ventricle. After discussion in a multi-disciplinary team, the large cement embolism was successfully removed by a combination of endovascular procedure and an inferior vena cava exploration. Surgeons must consider the possibility of intra-cardiac cement embolism after PVP. A hybrid approach of an endovascular procedure and a vascular surgery may be a reasonable treatment option to minimize the surgical procedure in cases of a large intra-cardiac cement embolism.
Use of ultrasound in altitude decompression modeling
NASA Technical Reports Server (NTRS)
Olson, Robert M.; Pilmanis, Andrew A.
1993-01-01
A model that predicts the probability of developing decompression sickness (DCS) with various denitrogenation schedules is being developed by the Armstrong Laboratory, using human data from previous exposures. It was noted that refinements are needed to improve the accuracy and scope of the model. A commercially developed ultrasonic echo imaging system is being used in this model development. Using this technique, bubbles images from a subject at altitude can be seen in the gall bladder, hepatic veins, vena cava, and chambers of the heart. As judged by their motion and appearance in the vena cava, venous bubbles near the heart range in size from 30 to 300 M. The larger bubbles skim along the top, whereas the smaller ones appear as faint images near the bottom of the vessel. Images from growing bubbles in a model altitude chamber indicate that they grow rapidly, going from 20 to 100 M in 3 sec near 30,000 ft altitude. Information such as this is valuable in verifying those aspects of the DCS model dealing with bubble size, their growth rate, and their site of origin.
Lin, Wei-Ching; Chen, Jeon-Hor; Westphalen, Antonio; Chang, Han; Chiang, I-Ping; Chen, Cheng-Hong; Wu, Hsi-Chin; Lin, Chien-Heng
2016-05-01
Although the second peak of the age distribution of rhabdomyosarcoma (RMS) is at adolescence, renal RMS is extremely rare at this age group. This tumor is indistinguishable from other renal tumors based on clinical and imaging findings, and the diagnosis relies on histology and immunohistochemical staining. We report a unique case of adolescent renal RMS associated with tumor thrombus extending into the inferior vena cava (IVC) and right atrium.An 18-year-old female adolescent presented with shortness of breath and palpitations, associated with right flank discomfort, and hematuria. A pleomorphic-type renal RMS with Budd-Chiari syndrome and arrhythmia induced by IVC and RA thrombosis was diagnosed. Despite complete tumor resection, the patient developed multiple lung metastases a month after surgery. Chemotherapy was recommended, but the patient declined. She died within a year of the initial operation.Adolescent renal RMS is rare and associated with poor outcome. Early aggressive multimodal therapy seems to be appropriate, in particular, in the presence of tumor thrombosis.
Takamatsu, Manabu; Matsuda, Takeru; Kawaguchi, Katsunori; Ku, Yonson
2007-11-01
A 61-year-old male was admitted for advanced hepatocellular carcinoma (HCC) with multiple lung metastases and tumor thrombus in the portal vein and superior vena cava. At first, we planned to perform transcatheter arterial embolization (TAE) to avoid the rupture of the liver tumor. But, due to the severe liver dysfunction, ie Child-Pugh C and 36% ICG R15, hepatic arterial infusion (HAI) of epirubicin 40 mg was performed. After that, the patient was followed at the outpatient ward and his general condition has gradually improved without a special treatment. At the present, one year and ten month after HAI, the serum alpha-fetoprotein (AFP) is almost within normal limits and CT scans show that HCC with multiple lung metastases, and tumor thrombus in the portal vein and superior vena cava almost disappeared. Although, spontaneous regression of HCC was a rare phenomenon, it might have played a major role in the good anticancer efficacy of this patient as well as high anti-cancer agent sensitivity of his liver tumor.
Gadzijev, E M; Ravnik, D; Stanisavljevic, D; Trotovsek, B
1997-01-01
The aim of this study was to determine the venous drainage of the dorsal sector of the liver in order to define the differences between segments I and IX and their implications for sectorially and segmentally oriented hepatic surgery. The study was based on corrosion casts of 61 macroscopically healthy livers. The drainage pathways of veins at least 10 mm long and 1 mm wide were evaluated and statistically analysed. On average, 9 veins drained the two segments and three veins from both segments entered the inferior vena cava. In 95% of cases the veins from segment I drained predominantly into the inferior vena cava, whereas in segment IX this pathway was dominant in only 30% of cases. In 64% of cases a vein originating in segment IX entered the right hepatic v. The difference in the venous drainage of the two segments suggests that segment IX partly belongs to the neighbouring segments and may thus be only a paracaval region of the right liver.
Pulmonary endothelial pavement patterns.
Kibria, G; Heath, D; Smith, P; Biggar, R
1980-01-01
The appearance of the endothelial pavement pattern was studied in the pulmonary trunk, pulmonary veins, aorta, and inferior vena cava of the rat by means of silver staining of the cell borders. The endothelial cell in each of the four blood vessels was found to have its own distinctive shape, fusiform and pointed in the direction of blood flow in the case of the aorta and larger and more rectangular in the pulmonary trunk and pulmonary veins. Detailed quantitation of the dimensions and surface area of the endothelial cells in each blood vessel was carried out by a photographic technique. Pulmonary hypertension was induced in one group of rats by feeding them on Crotalaria spectabilis seeds. The endothelial pavement pattern in their pulmonary trunks became disrupted with many of the cells assuming a fusiform shape reminiscent of aortic endothelium. Many small, new endothelial cells formed in the pulmonary trunk suggesting division of cells to line the enlarging blood vessels. In contrast the endothelial cells of the inferior vena cava merely increased in size to cope with the dilatation of this vein. Images PMID:7385090
Sandhu, Harpreet Singh; Mahendrakar, Sampath Kumar Mahadevappa; Ladhani, Sulaiman Sadruddin; Khan, Azizullah Hafizullah; Loya, Yunus Shafi
2017-07-01
Breast carcinoma is the most common invasive cancer in women worldwide. It metastasizes commonly to bone, lungs, regional lymph nodes and brain. Cardiac metastasis of lung and breast cancers is a known but rare complication of advanced disease with tumour metastasising to pericardium via the locoregional lymphatic system. Here we present a case of 59-year-old female presenting with right upper limb oedema, facial puffiness and features of Superior Vena Cava (SVC) syndrome 15 years after mastectomy and adjuvant chemotherapy, radiotherapy for carcinoma of the right breast. Further evaluation revealed extensive thrombus invading the right internal jugular vein, subclavian vein, SVC with intraluminal extension into right atrium causing ball in a loop obstruction at tricuspid valve. Whole body Positron emission tomography scan confirmed the diagnosis of extensive metastatic disease and patient was managed on palliative therapy. Haematogenous spread and intraluminal growth of metastatic deposits from breast carcinoma 15 years ago is rare and clinical presentation as SVC obstruction has not been reported in our review of literature.
2012-01-01
Background Rapid and accurate diagnosis and management can be lifesaving for patients with acute dyspnea. However, making a differential diagnosis and selecting early treatment for patients with acute dyspnea in the emergency setting is a clinical challenge that requires complex decision-making in order to achieve hemodynamic balance, improve functional capacity, and decrease mortality. In the present study, we examined the screening potential of rapid evaluation by lung-cardiac-inferior vena cava (LCI) integrated ultrasound for differentiating acute heart failure syndromes (AHFS) from primary pulmonary disease in patients with acute dyspnea in the emergency setting. Methods Between March 2011 and March 2012, 90 consecutive patients (45 women, 78.1 ± 9.9 years) admitted to the emergency room of our hospital for acute dyspnea were enrolled. Within 30 minutes of admission, all patients underwent conventional physical examination, rapid ultrasound (lung-cardiac-inferior vena cava [LCI] integrated ultrasound) examination with a hand-held device, routine laboratory tests, measurement of brain natriuretic peptide, and chest X-ray in the emergency room. Results The final diagnosis was acute dyspnea due to AHFS in 53 patients, acute dyspnea due to pulmonary disease despite a history of heart failure in 18 patients, and acute dyspnea due to pulmonary disease in 19 patients. Lung ultrasound alone showed a sensitivity, specificity, negative predictive value, and positive predictive value of 96.2, 54.0, 90.9, and 75.0%, respectively, for differentiating AHFS from pulmonary disease. On the other hand, LCI integrated ultrasound had a sensitivity, specificity, negative predictive value, and positive predictive value of 94.3, 91.9, 91.9, and 94.3%, respectively. Conclusions Our study demonstrated that rapid evaluation by LCI integrated ultrasound is extremely accurate for differentiating acute dyspnea due to AHFS from that caused by primary pulmonary disease in the emergency setting. PMID:23210515
Shi, Yuan; Zhang, Wei; Deng, Yong-lin; Zhang, Ya-min; Zhang, Quan-sheng; Zhang, Wei-ye; Zheng, Hong; Pan, Cheng; Shen, Zhong-Yang
2015-01-01
To improve the technique of suprahepatic vena cava (SHVC) reconstruction in rat OLT, novel magnetic rings were designed and manufactured to facilitate reconstruction of SHVC and shorten the anhepatic time. One-hundred and twenty adult male Wistar rats were randomly divided into two groups: rings group (n = 30), using magnetic rings for SHVC reconstruction; suture group (n = 30), 7/0 prolene suture was used for SHVC running anastomosis as control. Cuff techniques were used for portal vein and infrahepatic vena cava reconstruction as Kamada and Calne described. The bile duct was reconnected with a stent. The hepatic re-arterialization was omitted. In the rings group, the SHVC reconstruction took 0.91 ± 0.24 (mean ± SD) min; the anhepatic phase and the recipient operation time were 5.63 ± 0.65 min and 36.02 ± 8.02 min, respectively. In suture group, the anastomotic time of SHVC was 10.40 ± 2.11 min; the anhepatic phase and the recipient operation time were 17.76 ± 2.51 and 49.38 ± 12.06 min, respectively, and there was statistically significant difference between the two groups. The ALT levels reached peak at 24 h post-OLT (186.2 ± 32.5 IU/l) and restored to normal level at 96 h gradually. In the rings group, 29 of 30 rats survived at day 7 and 28 of 30 rats survived at day 30. In contrast, only 25 of 30 recipients in suture group remained alive at day 7 and 22 of 30 remained alive at day 30 (P < 0.05). Better anastomotic healing was founded in rings group by pathology and scanning electron microscope. The magnetic rings technique provides a novel, simple method for SHVC reconstruction of OLT in rat. It significantly shortens anhepatic phase, while the success rate of the operation is satisfactory. © 2014 Steunstichting ESOT.
Wang, Chih-Wei; Liu, Yi-Jui; Lee, Yi-Hsiung; Hueng, Dueng-Yuan; Fan, Hueng-Chuen; Yang, Fu-Chi; Hsueh, Chun-Jen; Kao, Hung-Wen; Juan, Chun-Jung; Hsu, Hsian-He
2014-01-01
Purpose To investigate the performance of hematoma shape, hematoma size, Glasgow coma scale (GCS) score, and intracerebral hematoma (ICH) score in predicting the 30-day mortality for ICH patients. To examine the influence of the estimation error of hematoma size on the prediction of 30-day mortality. Materials and Methods This retrospective study, approved by a local institutional review board with written informed consent waived, recruited 106 patients diagnosed as ICH by non-enhanced computed tomography study. The hemorrhagic shape, hematoma size measured by computer-assisted volumetric analysis (CAVA) and estimated by ABC/2 formula, ICH score and GCS score was examined. The predicting performance of 30-day mortality of the aforementioned variables was evaluated. Statistical analysis was performed using Kolmogorov-Smirnov tests, paired t test, nonparametric test, linear regression analysis, and binary logistic regression. The receiver operating characteristics curves were plotted and areas under curve (AUC) were calculated for 30-day mortality. A P value less than 0.05 was considered as statistically significant. Results The overall 30-day mortality rate was 15.1% of ICH patients. The hematoma shape, hematoma size, ICH score, and GCS score all significantly predict the 30-day mortality for ICH patients, with an AUC of 0.692 (P = 0.0018), 0.715 (P = 0.0008) (by ABC/2) to 0.738 (P = 0.0002) (by CAVA), 0.877 (P<0.0001) (by ABC/2) to 0.882 (P<0.0001) (by CAVA), and 0.912 (P<0.0001), respectively. Conclusion Our study shows that hematoma shape, hematoma size, ICH scores and GCS score all significantly predict the 30-day mortality in an increasing order of AUC. The effect of overestimation of hematoma size by ABC/2 formula in predicting the 30-day mortality could be remedied by using ICH score. PMID:25029592
Outcomes following the Kawashima procedure for single-ventricle palliation in left atrial isomerism.
Vollebregt, Anne; Pushparajah, Kuberan; Rizvi, Maleeha; Hoschtitzky, Andreas; Anderson, David; Austin, Conal; Tibby, Shane M; Simpson, John
2012-03-01
Patients with left atrial isomerism and interrupted inferior vena cava palliated with a superior cavopulmonary connection or Kawashima procedure (KP) have a high incidence of developing pulmonary arteriovenous malformations. The necessity for hepatic vein redirection (HVR) and its timing remains a controversy. We aimed to assess the clinical outcome of patients with left atrial isomerism following a KP. The main end points were death, requirement for HVR and the impact of HVR on oxygen saturation. Retrospective review of 21 patients with a diagnosis of left atrial isomerism, interruption of the inferior vena cava and single-ventricle physiology managed with a KP at a single centre between January 1990 and March 2010. Twenty-one patients had a KP, with 12 subsequently undergoing HVR. There was relatively a constant monthly decrement in the proportion of patients who were free from death or HVR up until 60 months following the KP, with a dramatic increase in the hazard after this time. The Cox proportional hazards regression model demonstrated a reduced early risk for HVR or death in patients who underwent pulmonary artery banding versus arterial shunt as the primary procedure (hazard ratio: 0.10; P = 0.01), and an increased risk with bilateral superior vena cavas (SVCs) (hazard ratio: 3.4; P = 0.04) and age at KP (hazard ratio: 1.02 per month increase in age at KP; P = 0.02). HVR mortality was relatively high with 3 of 12 patients dying in the early postoperative period with profound cyanosis. The timing of HVR after the KP did not influence the postoperative rate of increase in oxygen saturation. These findings confirm that the majority of patients who undergo a KP will require HVR. Patients who are older at the time of the KP or having an initial arterial shunt or bilateral SVCs are at higher risk of HVR or death. The relatively high mortality at HVR was characterized by severe postoperative cyanosis.
Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir
2016-05-01
To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
A Life-Threatening Mediastinal Hematoma After Central Venous Port System Implantation
Sarach, Janine; Zschokke, Irin; Melcher, Gian A.
2015-01-01
Patient: Female, 68 Final Diagnosis: Mediastinal hematoma Symptoms: Agitation • severe hemodynamic instability • severe respiratory distress Medication: — Clinical Procedure: Cardiopulmonary resuscitation • reintubation • thoracic drain Specialty: Surgery Objective: Diagnostic/therapeutic accidents Background: We report a case of surgical central venous port system implantation using Seldinger’s technique with a life-threatening mediastinal hematoma due to the perforation of the superior vena cava. Case Report: A 68-year-old woman was admitted to our institution for port implantation. Open access to the cephalic vein and 2 punctures of the right subclavian vein were unsuccessful. Finally, the port catheter could be placed into the superior vena cava using Seldinger’s technique. As blood aspiration via the port catheter was not possible, fluoroscopy was performed, revealing mediastinal contrast extravasation without contrasting the venous system. A new port system could be placed in the correct position without difficulties. After extubation, the patient presented with severe respiratory distress and required consecutive cardiopulmonary resuscitation and reintubation. The CT scan showed a significant hematoma in the lower neck and posterior mediastinum with tracheal compression. We assumed a perforation of the superior vena cava with the tip of the guidewire using Seldinger’s technique. Long-term intensive treatment with prolonged ventilation and tracheotomy was necessary. The port system had to be subsequently explanted due to infection. Conclusions: Mediastinal hematoma is a rare but life-threatening complication associated with central venous catheterization using Seldinger’s technique. Perforation occurs most often during central venous catheterization in critical care. Mediastinal hematoma is an example of a mechanical complication occurring after central venous catheterization, which has been described only a few times in the literature to date. This case highlights the importance of awareness of possible, rare, life-threatening complications during port implantation, mostly performed in multimorbid patients by surgeons in training. PMID:26703924
Model of complete separation of the hepatic veins from the systemic venous system.
Brizard, C P; Goussef, N; Chachques, J C; Carpentier, A F
2000-12-01
In patients undergoing a Fontan operation, partial diversion of the hepatic veins to the pulmonary venous atrium has been tried with various techniques. They failed because of the development of intrahepatic collaterals leading to an unacceptable right-to-left shunting. We postulate that to avoid the formation of intrahepatic collaterals, the totality of the liver has to be drained into the same pressure compartment. We have designed a model of cavopulmonary anastomosis in which a prosthetic conduit reproduces an azygos continuation, associated with the diversion of the totality of the hepatic venous return. This article reports on the early hemodynamics and the fate of the separation of the two venous compartments in long-term survivors. Eighteen goats were operated on; the pulmonary artery and hepatic vein pressures were recorded. During month 2, an opacification of the inferior vena cava and the cavopulmonary connection was performed. Between months 6 and 14, another opacification was performed, together with pressure recording at both ends of the conduit. Postoperatively the pulmonary artery pressure was pulsatile with a mean of 10 mm Hg and the hepatic vein pressure was 0 mm Hg. The first angiogram showed patent tubes with fast progression of the contrast. Throughout the inferior vena cava injection, there was no opacification of the portal or hepatic veins. The late study showed a narrowed conduit in all animals. During the injection, a collateral was injected, feeding into the inferior mesenteric vein. No collateral circulation could be seen draining directly into the liver. The median gradient between the two ends of the conduit was 11 mm Hg. The isolation of the entire hepatic venous drainage is feasible and efficient for the separation of two pressure compartments. No intrahepatic collaterals are observed with this model at short- or long-term follow-up. The separation of the hepatic venous drainage should persist without collateral circulation as long as the inferior vena cava pressure stays at the levels observed in Fontan circulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less
Ohta, Mineto; Nakanishi, Chikashi; Kawagishi, Naoki; Hara, Yasuyuki; Maida, Kai; Kashiwadate, Toshiaki; Miyazawa, Koji; Yoshida, Satoru; Miyagi, Shigehito; Hayatsu, Yukihiro; Kawamoto, Shunsuke; Matsuda, Yasushi; Okada, Yoshinori; Saiki, Yoshikatsu; Ohuchi, Noriaki
2016-12-01
Recurrent hepatocellular carcinoma accompanied by a right atrial tumor thrombus is rare. No standard treatment modality has been established. Surgical treatment may be the only curative treatment; however, surgery has been considered high risk. We herein describe a patient who underwent resection of a recurrent right atrial tumor thrombus under normothermic cardiopulmonary bypass on a beating heart. A 60-year-old man underwent a right hepatectomy for hepatocellular carcinoma with diaphragm invasion. During the preoperative cardiac screening, he was diagnosed with an old myocardial infarction with triple-vessel coronary disease. Percutaneous coronary intervention was performed for the left anterior descending artery and left circumflex coronary artery. High-grade stenosis remained in his right coronary artery. Nine months later, computed tomography showed recurrent hepatocellular carcinoma in the diaphragm and a tumor thrombus extending from the suprahepatic inferior vena cava into the right atrium. Surgical resection of the recurrent tumor was performed through a right subcostal incision with xiphoid extension and median sternotomy. The recurrent tumor was incised with the diaphragm and pericardium. Intraoperative ultrasonography revealed that the tumor thrombus was free from right atrium wall invasion and that the right atrium could be clamped just proximal to the tumor thrombus. The right atrium, infrahepatic vena cava, left and middle hepatic veins, and hepatoduodenal ligament were encircled. Cardiopulmonary bypass was performed to prevent ischemic heart disease caused by intraoperative hypotension. Total hepatic vascular exclusion was then performed under normothermic cardiopulmonary bypass on heart beating. The inferior vena cava wall was incised. The tumor thrombus with the diaphragmatic recurrent tumor was resected en bloc. The patient had a favorable clinical course without any complications. The recurrent hepatocellular carcinoma in the diaphragm and the right atrial tumor thrombus were safely resected using normothermic cardiopulmonary bypass on heart beating.
NASA Astrophysics Data System (ADS)
Geldmacher, J.; Hoernle, K.; Gill, J. B.; Hauff, F.; Heydolph, K.
2016-12-01
It is generally accepted that subducted oceanic crust and sediments contribute to the composition of arc magmas. Systematic variations of input parameters (including age, subduction angle, and chemical composition of the subducting material) make the Central American Volcanic Arc (CAVA), which extends from Guatemala in the northwest through El Salvador, Honduras, Nicaragua, Costa Rica and Panama to the southeast, a prime study object. We present a comprehensive (major and trace element and Sr-Nd-Pb-Hf isotope data) and consistent (all data generated in the same labs using the same methods and data reduction procedures) compilation of published and unpublished Holocene mafic volcanic rocks sampled along the entire arc. New data include Sr and, for the first time, Hf isotope data from the entire CAVA as well as major and trace element data for 43 samples from southern Nicaragua and central Costa Rica from which only isotopic compositions were previously published. The combined elemental and isotopic data confirm the influence of distinct subduction components on the composition of CAVA magmas. Along-arc geochemical variations (especially delta 208Pb/204Pb) of volcanic front magmas in Costa Rica and Panama have been explained by the different compositions of seamounts/ridges of the isotopically zoned Galápagos hotspot track that covers the subducting Cocos Plate in this sector of the arc (Hoernle et al. 2008, Nature 451). Our new data confirm this relationship with arc lavas from Costa Rica having higher 87Sr/86Sr ratios than those from western Panama reflecting a similar spatial-compositional distinction in the subducting hotspot track beneath them. In contrast, 176Hf/177Hf shows no comparable variations in this sector of the arc, indicating that the Hf is primarily derived from the mantle wedge rather than the subducting slab. Although small degree hydrous melts are believed to fertilize the mantle wedge beneath Costa Rica, residual zircon may hold back the Hf.
The caudate lobe of the liver: implications of embryology and anatomy for surgery.
Abdalla, Eddie K; Vauthey, Jean-Nicolas; Couinaud, Claude
2002-10-01
The anatomy of the caudate lobe has technical and possibly oncologic implications for surgeons. The complex anatomy of the lobe is clarified by embryologic and anatomic analysis. This posterior sector is embryonically and anatomically independent of the right and left liver and the main portal fissure. The caudate lobe represents the only part of the liver that is in contact with the vena cava, except at the entrance of the main hepatic veins into the vena cava, and provides an anastomosis between the hepatic veins and vena cava. The entire caudate lobe is a single anatomic segment that is defined by the presence of portal venous and hepatic arterial branches, which supply the lobe, draining biliary ducts, and hepatic veins. Because no separate veins, arteries, or ducts can be defined for the right paracaval portion of the posterior liver and because pedicles cross the proposed division between the right and left caudate, the concept of segment IX is abandoned. The significance of caudate anatomy is reflected in the increase in the frequency and safety of major hepatic resection for primary and metastatic tumors in the liver. Right hepatic lobectomy routinely involves resection of the right portion of the caudate lobe (C. Couinaud, unpublished data, 1999). In the case of hilar bile duct cancer, which may extend into the dorsal ducts (especially the right lateral duct), partial or total caudate lobectomy is often necessary for complete extirpation of the tumor. Isolated caudate lobectomy can be performed for hepatocellular carcinoma that arises in the caudate lobe or for other tumors that arise in the lobe. The caudate lobe can be resected as part of the donor liver in preparation for a living related donor transplantation. Knowledge of the surgical anatomy of the caudate lobe is an essential part of the repertoire for surgeons who perform liver transplants or treat hepatobiliary cancer.
Oppermann, Marc; Padberg, Stephanie; Kayser, Angela; Weber‐Schoendorfer, Corinna; Schaefer, Christof
2013-01-01
Aims Angiotensin‐II receptor 1 antagonists (AT1‐antagonists) may cause severe and even lethal fetopathy in late pregnancy. However, exposure still occurs in spite of warnings in package leaflets. This study aimed to assess the risk of fetopathy, the sensitive time window, and possible new symptoms in prospective as well as retrospective cases with AT1‐antagonist treatment during the second or third trimester of pregnancy. Methods Patients were enrolled by the Berlin Institute for Clinical Teratology and Drug Risk Assessment in Pregnancy between 1999 and 2011 through risk consultation. Symptoms defined as indicative of AT1‐antagonist fetopathy were: oligo‐/anhydramnios, renal insufficiency, lung hypoplasia, joint contractures, skull hypoplasia and fetal/neonatal death. Results In 5/29 (17%) prospectively enrolled cases with AT1‐antagonist exposure beyond the first trimester oligo‐/anhydramnios was diagnosed. Two infants showed additional symptoms of fetopathy. The risk is more than 30% if treatment continues beyond the 20th week of pregnancy. Oligo‐/anhydramnios was reversible after AT1‐antagonist withdrawal. Among 16 retrospective case reports, three infants presented with a thrombosis of the inferior vena cava in the vicinity of the renal veins. Four out of 13 live births did not survive. Conclusions Our survey suggests that the risk increases with duration of AT1‐antagonist treatment into late pregnancy and oligo‐/anhydramnios may be reversible after AT1‐antagonist discontinuation. Thrombosis of inferior vena cava may be a new feature of AT1‐antagonist fetopathy. AT1‐antagonist medication during pregnancy constitutes a considerable risk and must be discontinued immediately. In case of indicative diagnostic findings in either the fetus or newborn, previous maternal AT1‐antagonist exposure should be considered. PMID:22816796
Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P
2018-06-01
The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.
VizieR Online Data Catalog: Dynamics of A3266. I. An Optical View. (Dehghan+, 2017)
NASA Astrophysics Data System (ADS)
Dehghan, S.; Johnston-Hollitt, M.; Colless, M.; Miller, R.
2017-03-01
Spectroscopic redshifts for 1303 galaxies within a 2-degree field around Abell 3266. Redshifts are listed for 880 galaxies observed with the 2dF instrument on the Anglo-Australian Telescope (Dehghan et al., 2017, this paper), 391 objects from the compilation of Quintana et al. (1996, Cat. J/AJ/112/36), 264 objects from the WIde-field Nearby Galaxy-cluster Survey (WINGS; Cava et al., 2009, Cat. J/A+A/495/707), and an additional 39 objects from various works in the literature within one degree of the nominal centre of A3266. The 880 galaxies from the 2dF sample were observed on 29 December 1997 and 5 October 1999. Four fibre configurations were observed, all covering a single 2-degree-diameter field around the nominal cluster centre of RA=04:31:09.7, DE=-61:28:40 (J2000). The data were reduced with the 2dfdr pipeline reduction software for 2dF, and redshifts were measured using a modified version of the program used for the 2dF Galaxy Redshift Survey (Colless et al., 2001MNRAS.328.1039C, Cat. VII/226). The positions of the AAO catalogue come from the UK Schmidt Telescope southern sky survey plate for field F118, scanned with the Automated Plate Measuring machine (Maddox et al., 1990MNRAS.243..692M). Full details can be found in the paper. (1 data file).
Dundie, A; Hayes, G; Scrivani, P; Campoy, L; Fletcher, D; Ash, K; Oxford, E; Moïse, N S
2017-04-01
A 10 week old female intact Staffordshire terrier was presented with a total of five congenital cardio-thoracic vascular anomalies consisting of a patent ductus arteriosus (PDA) with an aneurysmic dilation, pulmonic stenosis, persistent right aortic arch, aberrant left subclavian artery and persistent left cranial vena cava. These abnormalities were identified with a combination of echocardiogram and computed tomography angiography (CTA). The abnormalities were associated with esophageal entrapment, regurgitation, and volume overload of the left heart with left atrial and ventricular enlargement. A 2 cm diameter aneurysmic dilation at the junction of the PDA, right aortic arch and aberrant left subclavian artery presented an unusual surgical challenge and precluded simple circumferential ligation and transection of the structure. A full scale three dimensional model of the heart and vasculature was constructed from the CTA and plasma sterilized. The model was used preoperatively to facilitate surgical planning and enhance intraoperative communication and coordination between the surgical and anesthesia teams. Intraoperatively the model facilitated spatial orientation, atraumatic vascular dissection, instrument sizing and positioning. A thoracoabdominal stapler was used to close the PDA aneurysm prior to transection. At the four-month postoperative follow-up the patient was doing well. This is the first reported application of new imaging and modeling technology to enhance surgical planning when approaching correction of complex cardiovascular anomalies in a dog. Copyright © 2016 Elsevier B.V. All rights reserved.
[Portal perfusion with right gastroepiploic vein flow in liver transplant].
Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde
Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Congenital absence of the portal vein in a cat.
Holloway, Andrew; Groot, Louise; van der Schaaf, Klaartje
2018-01-01
A 9-month-old female neutered domestic shorthair cat presented with a history of episodic ptyalism, lethargy and abnormal behaviour. The clinical signs together with elevated pre- and post-prandial bile acid concentrations were consistent with hepatic encephalopathy (HE). In the absence of a portosystemic shunt (PSS) on abdominal ultrasound, medical management of HE was established with a protein-restricted diet and lactulose and the neurological signs resolved. Following an episode of acute vomiting and haemorrhagic diarrhoea at 19 months of age abdominal ultrasonography was repeated. The portal vein could not be demonstrated ultrasonographically; instead, portal vein tributaries were tortuous and communicated with the caudal vena cava (CdVC) at the level of the left kidney. CT angiography (CTA) confirmed the absence of the portal vein. CTA demonstrated the tortuous terminations of the portal tributaries, and several systemic veins, draining into the CdVC via a large-diameter paracaval vessel at the level of the left kidney. Gastrointestinal signs were stabilised and medical management for HE of a protein-restricted diet and lactulose was re-established. Congenital absence of the portal vein has not been described previously in the cat and should be considered in cats presenting with signs suggestive of a PSS and HE. The portal vein in the cat can be demonstrated using ultrasound, but complex congenital vascular malformations of the portal or systemic abdominal veins should be characterised using CTA and further distinguished from other vascular anomalies that may present with similar ultrasonographic features.
Factors associated with severity of sleep apnoea syndrome in patients with chronic kidney disease.
Tanaka, Akihito; Inaguma, Daijo; Ito, Eri; Kamegai, Naoki; Kato, Akiko; Mizutani, Minami; Shimogushi, Hiroya; Shinjo, Hibiki; Otsuka, Yasuhiro; Takeda, Asami
2017-08-01
Background In patients with chronic kidney disease (CKD), prevalence of sleep apnoea syndrome (SAS) is reported to be markedly high. However, the factors associated with severity of SAS in such patients rarely have been reported. Methods This was a cross-sectional study of 100 stable non-dialysis patients with CKD who attended a CKD educational programme from April 2014 to August 2015. Diagnosis of SAS and its severity were assessed using a type-3 portable monitor. Results Eighty-six men and 14 women with a mean age of 71.6 ± 9.7 years were included. Mean apnoea-hypopnoea index (AHI) was 26.0 ± 13.8. Severe SAS was seen in 39 patients. Significant differences in brain natriuretic peptide (BNP) level (213.6 ± 329.6 pg/mL vs 107.8 ± 141.3 pg/mL, P < 0.05) and cardiothoracic ratio (CTR, 52.4% ± 6.3% vs 49.6% ± 5.7%, P < 0.05) were seen between patients with and without severe SAS. After adjusting for various parameters, BNP level, CTR, and diameter of the inferior vena cava at the end of inhalation were found to correlate with AHI. Conclusions In patients with CKD, prevalence of severe SAS is extremely high. In these patients, fluid retention, rather than systolic or diastolic function, correlates with severity of SAS.
ERIC Educational Resources Information Center
Jordon, Kelly J.
2014-01-01
Our nation's schools are faced with numerous critical challenges and problems; meeting federal and state mandates, state standards, elevating academic achievement, increasing parental involvement, and violence in the schools (Gould, 2011; Kowalski & Cangemi, 2011; Simpson, LaCava, & Graner, 2004). Violence in many U.S. schools continues to…
Side-to-side cavo-cavostomy: a useful aid in "complicated" piggy-back liver transplantation.
Lerut, J; Gertsch, P
1993-01-01
Piggy-back liver transplantation is a useful technical variant of orthotopic liver transplantation. Its success can, however, be compromised by severe stenosis or obstruction of the recipient's inferior vena cava at the level of the anastomosis. A technique is described--side-to-side cavocavostomy--to resolve this difficult intraoperative situation.
Abnormal location of umbilical venous catheter due to Scimitar syndrome
Mart, Christopher R; Van Dorn, Charlotte S
2014-01-01
Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705
Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound
2016-10-01
with this study, Dr. Doucet has produced “Protocol Video USA-IVC Study (Version 5)” that is posted on youtube : https://youtu.be/54-Z6fiJpPY This video... youtube : https://youtu.be/54-Z6fiJpPY This video contains study design, procedures, inclusion/exclusion criteria and a demonstration to train clinical
Two cases of retroperitoneal haematoma caused by interaction between antibiotics and warfarin
Phillips, S; Barr, A; Wilson, E; Rockall, T A; Stebbing, J F
2006-01-01
Several commonly prescribed antibiotics are known to interact with warfarin, increasing its anticoagulant effect by different mechanisms. Retroperitoneal bleeding with consequent haematoma is recognised as a complication of over‐anticoagulation. Consequences, which are potentially fatal, include hypovolaemic shock and compression of retroperitoneal structures such as the ureter and inferior vena cava. PMID:16373793
Aycock, Kenneth I; Campbell, Robert L; Manning, Keefe B; Craven, Brent A
2017-06-01
Inferior vena cava (IVC) filters are medical devices designed to provide a mechanical barrier to the passage of emboli from the deep veins of the legs to the heart and lungs. Despite decades of development and clinical use, IVC filters still fail to prevent the passage of all hazardous emboli. The objective of this study is to (1) develop a resolved two-way computational model of embolus transport, (2) provide verification and validation evidence for the model, and (3) demonstrate the ability of the model to predict the embolus-trapping efficiency of an IVC filter. Our model couples computational fluid dynamics simulations of blood flow to six-degree-of-freedom simulations of embolus transport and resolves the interactions between rigid, spherical emboli and the blood flow using an immersed boundary method. Following model development and numerical verification and validation of the computational approach against benchmark data from the literature, embolus transport simulations are performed in an idealized IVC geometry. Centered and tilted filter orientations are considered using a nonlinear finite element-based virtual filter placement procedure. A total of 2048 coupled CFD/6-DOF simulations are performed to predict the embolus-trapping statistics of the filter. The simulations predict that the embolus-trapping efficiency of the IVC filter increases with increasing embolus diameter and increasing embolus-to-blood density ratio. Tilted filter placement is found to decrease the embolus-trapping efficiency compared with centered filter placement. Multiple embolus-trapping locations are predicted for the IVC filter, and the trapping locations are predicted to shift upstream and toward the vessel wall with increasing embolus diameter. Simulations of the injection of successive emboli into the IVC are also performed and reveal that the embolus-trapping efficiency decreases with increasing thrombus load in the IVC filter. In future work, the computational tool could be used to investigate IVC filter design improvements, the effect of patient anatomy on embolus transport and IVC filter embolus-trapping efficiency, and, with further development and validation, optimal filter selection and placement on a patient-specific basis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melancon, A; Jacobsen, M; Salatan, F
Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GEmore » Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.« less
Taniguchi, Tatsunori; Ohtani, Tomohito; Kioka, Hidetaka; Tsukamoto, Yasumasa; Onishi, Toshinari; Nakamoto, Kei; Katsimichas, Themistoklis; Sengoku, Kaoruko; Chimura, Misato; Hashimoto, Haruko; Yamaguchi, Osamu; Sawa, Yoshiki; Sakata, Yasushi
2018-01-12
This study sought to investigate whether elevated liver stiffness (LS) values at discharge reflect residual liver congestion and are associated with worse outcomes in patients with heart failure (HF). Transient elastography is a newly developed, noninvasive method for assessing LS, which can be highly reflective of right-sided filling pressure associated with passive liver congestion in patients with HF. LS values were determined for 171 hospitalized patients with HF before discharge using a Fibroscan device. The median LS value was 5.6 kPa (interquartile range: 4.4 to 8.1; range 2.4 to 39.7) and that of right-sided filling pressure, which was estimated based on LS, was 5.7 mm Hg (interquartile range: 4.1 to 8.2 mm Hg; range 0.1 to 18.9 mm Hg). The patients in the highest LS tertile (>6.9 kPa, corresponding to an estimated right-sided filling pressure of >7.1 mm Hg) had advanced New York Heart Association functional class, high prevalence of jugular venous distention and moderate/severe tricuspid regurgitation, large inferior vena cava (IVC) diameter, low hemoglobin and hematocrit levels, high serum direct bilirubin level, and a similar left ventricular ejection fraction compared with the lower tertiles. During follow-up periods (median: 203 days), 8 (5%) deaths and 33 (19%) hospitalizations for HF were observed. The patients in the highest LS group had a significantly higher mortality rate and HF rehospitalization (hazard ratio: 3.57; 95% confidence interval: 1.93 to 6.83; p < 0.001) compared with the other tertiles. Although LS correlated with IVC diameter and serum direct bilirubin and brain natriuretic peptide levels, LS values were predictive of worse outcomes, even after adjustment for these indices. These data suggest that LS is a useful index for assessing systemic volume status and predicting the severity of HF, and that the presence of liver congestion at discharge is associated with worse outcomes in patients with HF. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Toib, Amir; Goldstein, Seth B; Khanna, Geetika; Canter, Charles E; Lee, Caroline K; Balzer, David T; Singh, Gautam K
2012-01-01
We describe a case of an infant with a single ventricle physiology, who presented with spontaneous microbubbles originating from her inferior vena cava. Imaging revealed a persistent patent ductus venosus, leading to a portosystemic shunt, streaming the microbubbles into the heart. We discuss the possible mechanisms for this rare phenomenon in a child. © 2011 Wiley Periodicals, Inc.
Anesthesia in a Combat Environment
1981-09-25
infusion in those patients where disruption of iliac vei~ns or inferior vena cava is a possibility (pelvic, abdominal, or chest trauima), A cathetor...minimal or no decrease in cardiac output, stroke volume, left -ventricular work, stroke work, and mean arterial pressure (5). Halothane, fluroxene, and...healthy young male volunteers to preserve cardiac output unchanged, decrease stroke volume, arterial pressure, peripheral resistance, 02 and left
Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.
Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F
2018-05-03
To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.
Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2017-12-01
Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.
Eldeen, F Z; Lee, C-F; Lee, C-S; Chan, K-M; Lee, W-C
2013-03-01
The modified piggyback technique with side-to-side cavocavostomy decreases the risk of outflow obstruction compared with the standard piggyback method. However, this modification is not ideal for recipients who receive a graft that is voluminous or bears an enlarged caudate lobe. We modified the inferior vena cava (IVC) preservation technique against deleterious complications of compression by using a passing loop. A 49-year-old woman, who underwent orthotopic liver transplantation for hepatic failure, was allocated a large-size liver. In anticipation of serious caval compression due to the voluminous grafts, we kept the suprahepatic or infrahepatic donor caval cuffs open for an anastomosis. The first anastomosis was performed between suprahepatic donor IVC cuff and recipient middle-left hepatic vein common channel; the second anastomosis was a terminolateral cavocavostomy between infrahepatic donor IVC cuff and the anterior wall of the recipient's IVC. When the liver circulation was restored, the donor retrohepatic vena cava served as a passing loop for both hepatic venous outflow and infra-diaphragmatic venous return to bypass possible IVC compression. Our technique may solve a dilemna for patients receiving voluminous liver grafts. Copyright © 2013 Elsevier Inc. All rights reserved.
Kinaci, Erdem; Kayaalp, Cuneyt; Yilmaz, Sezai; Otan, Emrah
2014-01-01
Hepatic venous outflow obstruction following liver transplantation is rare but disastrous. Here we described a 14-year-old boy who underwent a split right lobe liver transplantation with modified (side-to-side) piggyback technique which resulted in hepatic venous outflow obstruction. When the liver graft was lifted up, the outflow drainage returned to normal but when it was placed back into the abdomen, the outflow obstruction recurred. Because reanastomosis would have resulted in hepatic reischemia, alternatively, a second infrahepatic cavocavostomy was planned without requiring hepatic reischemia. During this procedure, the first assistant hung the liver up to provide sufficient outflow and the portal inflow of the graft continued as well. We only clamped the recipient's infrahepatic vena cava and the caudal cuff of the graft cava. After the second end-to-side cavocaval anastomosis, the graft was placed in its orthotopic position and there was no outflow problem anymore. The patient tolerated the procedure well and there were no problems after three months of follow-up. A second cavocavostomy can provide an extra bypass for some hepatic venous outflow problems after piggyback anastomosis by avoiding hepatic reischemia.
Kinaci, Erdem; Kayaalp, Cuneyt; Yilmaz, Sezai; Otan, Emrah
2014-01-01
Hepatic venous outflow obstruction following liver transplantation is rare but disastrous. Here we described a 14-year-old boy who underwent a split right lobe liver transplantation with modified (side-to-side) piggyback technique which resulted in hepatic venous outflow obstruction. When the liver graft was lifted up, the outflow drainage returned to normal but when it was placed back into the abdomen, the outflow obstruction recurred. Because reanastomosis would have resulted in hepatic reischemia, alternatively, a second infrahepatic cavocavostomy was planned without requiring hepatic reischemia. During this procedure, the first assistant hung the liver up to provide sufficient outflow and the portal inflow of the graft continued as well. We only clamped the recipient's infrahepatic vena cava and the caudal cuff of the graft cava. After the second end-to-side cavocaval anastomosis, the graft was placed in its orthotopic position and there was no outflow problem anymore. The patient tolerated the procedure well and there were no problems after three months of follow-up. A second cavocavostomy can provide an extra bypass for some hepatic venous outflow problems after piggyback anastomosis by avoiding hepatic reischemia. PMID:24959369
A case of left inferior vena cava.
Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S
2001-12-01
A case of left inferior vena cava (IVC) was found in a 72-year-old male cadaver during student dissection practice in 1999 at Gifu University School of Medicine. It was formed by junction of the left and right common iliac veins at the lower left corner of the 5th lumbar vertebra. This IVC (15-mm caliber) ascended 82 mm along the left side of the abdominal aorta dorsally to the ureter. Receiving the left renal vein, it became 21 mm in caliber and ran obliquely upward for 43 mm across the abdominal aorta. As soon as it received two right renal veins at the level of the 2nd lumbar vertebra, the IVC (25-mm caliber) turned directly above. The present case belongs to Type C of the classification of McClure and Butler (1925), which is based on the combinations of the left and right IVCs, and on their location relative to the ureters. The present case also belongs to Type 1 of the classification of Yoshida et al. (1981). We consider that left IVC in the present case is mainly caused by disappearance of the right supracardinal vein and persistence of the left one during the embryological development of the IVC.
Two cases of the double inferior venae cavae.
Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S
2000-10-01
Two cases of the double inferior venae cavae (IVC) were found during the student dissection practice in 1997 in Gifu University School of Medicine. On the first case (70-year-old male), the calibers of the right and left IVC were 15 mm and 13 mm, respectively. An anastomosis (4-mm caliber) ran obliquely from the left internal iliac vein to the right IVC. On the second case (86-year-old male), the calibers of the right and left IVC were 15 mm and 10 mm, respectively. We found no anastomosis between the right and left IVC. Each IVC was observed behind the ureter. Both cases belong to Type BC of the classification of McClure and Butler (1925), that is based on the combinations of the right and left IVC, and on their location to the ureters. Both cases also belong to Type II-b-2 of the classification of Takemoto et al. (1978), that is based on the calibers of the right and left IVC and on the running course of the interiliac vein. These are the first and second cases among 808 cadavers in Gifu University School of Medicine and the 93rd and 94th cases in Japan since 1901.
Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike
2018-02-24
To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.
The clinical anatomy of congenital portosystemic venous shunts.
Stringer, Mark D
2008-03-01
Congenital portosystemic venous shunts are rare. Their gross anatomy has not been well defined. Four different varieties of congenital portosystemic venous shunts are described in six children seen during a 10-year period, focusing on the anatomy of the shunt as determined by imaging studies and surgery. A detailed review of the literature indicates that congenital portosystemic venous shunts are best classified as: extrahepatic or intrahepatic. Extrahepatic shunts may be further subdivided into portocaval shunts (type 1 end-to-side and type 2 side-to-side) and others. Intrahepatic shunts are due to an abnormal intrahepatic connection between the portal vein and hepatic vein/inferior vena cava or a persistent patent ductus venosus. Additional congenital anomalies, particularly cardiac malformations, may be associated with any type. Some congenital intrahepatic portosystemic venous shunts close spontaneously in infancy; all other congenital portosystemic venous shunts tend to remain patent. To a variable extent, depending largely on the volume and duration of the shunt, affected individuals are at risk of developing hepatic encephalopathy and/or an intrahepatic tumor. The key to understanding the pathogenesis of these shunts lies in the normal developmental mechanisms underlying the formation of the portal vein and inferior vena cava in the embryo. Copyright 2008 Wiley-Liss, Inc.
Van Praagh, S; Geva, T; Lock, J E; Nido, P J; Vance, M S; Van Praagh, R
2003-01-01
Since the posterior wall of the right superior vena cava (RSVC) is contiguous with the anterior wall of the right upper pulmonary veins, a localized defect in this common wall may create a cavopulmonary venous confluence without eliminating the normal connection of the same right pulmonary veins with the left atrium (LA). Through this defect, blood of the unroofed right pulmonary veins will drain into the RSVC and right atrium (RA), and blood from the RSVC may shunt into the right pulmonary veins and LA. Hemodynamically, the RSVC will become biatrial. If the RSVC blood flows preferentially into the LA, its right atrial orifice will become stenotic or even atretic. If atretic, the normally positioned RSVC will drain entirely into the LA. In this report, we present the clinical and anatomical findings of two postmortem cases with biatrial drainage of the RSVC. We also document the clinical, echocardiographic, angiocardiographic, and surgical data of a living patient with left atrial drainage of the RSVC and tetralogy of Fallot with pulmonary atresia. The relevant literature and surgical treatment are reviewed, and the morphogenesis of the biatrial and left atrial RSVC is considered.
Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doody, Orla, E-mail: orla_doody@hotmail.com; Noe, Geertje; Given, Mark F.
Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range,more » 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.« less
2014-01-01
Objective: The purpose of this study was to review patients who underwent inferior vena cava (IVC) resection with concomitant malignant tumor resection and to consider the operative procedures and the outcomes. Materials and Methods: Between 2000 and 2012, 41 patients underwent resection of malignant tumors concomitant with surgical resection of the IVC at our institute. The records of these patients were retrospectively reviewed. Results: Primary tumor resections included nephrectomy, hepatectomy, retroperitoneal tumor extirpation, lymph node dissection, and pancreaticoduodenectomy. The IVC interventions were partial resection in 23 patients and total resection in 18 patients. Four patients underwent IVC replacement. Operation-related complications included pulmonary embolism, acute myocardial infarction, deep vein thrombosis, leg edema and temporary hemodialysis. There were no operative deaths. The mean follow-up period was 24.9 months (range: 2–98 months). The prognosis depended on the type and stage of the tumor. Conclusion: Resection and reconstruction of the IVC can be performed safely if the preoperative evaluations and surgical procedures are performed properly. The IVC resection without reconstruction was permissive if the IVC was completely obstructed preoperatively, but it may also be considered in cases where the IVC is not completely obstructed. PMID:24995055
Stipe Length as an Indicator of Reproductive Maturity in the Kelp Ecklonia cava
NASA Astrophysics Data System (ADS)
Kim, Sangil; Youn, Suk Hyun; Oh, Hyun-Ju; Choi, Sun Kyeong; Kang, Yun Hee; Kim, Tae-Hoon; Lee, Hyuk Je; Choi, Kwang-Sik; Park, Sang Rul
2018-05-01
We conducted testing to determine whether stipe length is a useful indicator of reproductive maturity in the kelp Ecklonia cava, a species that plays a pivotal role in ecosystem functioning and services in subtidal areas. Approximately 100 sporophytes with stipes of various lengths were collected during the fertile period (July-November, 2013). We investigated the relationships between stipe length and other morphological characteristics to determine whether stipe length could indicate the age of reproductive maturity. Primary blade length, longest blade length, thallus height, and total length showed significant relationships with stipe length. The length of the primary and longest blades gradually declined as stipe length increased above 125 mm. Zoosporangial sori were found on the blades of more than 70% of individuals with stipes longer than 125 mm, but on only 8% of individuals with stipes less than 125 mm long. Stipe length therefore seems to be an acceptable proxy for reproductive maturity. Another factor to consider, however, is that all specimens with zoosporangial sori, regardless of stipe length, had a dry weight of 80 g or more; thus, individual biomass may also be an important parameter influencing the initiation of reproduction.
Budd-Chiari syndrome and liver transplantation
Akamatsu, Nobuhisa; Sugawara, Yasuhiko; Kokudo, Norihiro
2015-01-01
Summary Budd-Chiari syndrome involves obstruction of hepatic venous outflow tracts at various levels from small hepatic veins to the inferior vena cava and is the result of thrombosis or its fibrous sequelae. There is a conspicuous difference in its etiology in the West and the East. Myeloproliferative disease predominates in the West and obstruction of the vena cava predominates in the East. The clinical presentation and clinical manifestations are so varied that it should be suspected in any patient with acute or chronic liver dysfunction. It should be treated with step-wise management. First-line therapy should be anticoagulation with medical treatment of the underlying illness, and interventional revascularization and TIPS are indicated in the event of a lack of response to medical therapy. Liver transplantation may be indicated as a rescue treatment or for fulminant cases with promising results. This step-by-step strategy has achieved a 5-year transplant-free survival rate of 70% and a 5-year overall survival rate of 90%. Living donor liver transplantation can also be used for patients with Budd-Chiari syndrome if deceased donor livers are scarce, but it requires a difficult procedure particularly with regard to venous outflow reconstruction. PMID:25674385
Massive retroperitoneal haemorrhage after extracorporeal shock wave lithotripsy (ESWL).
Inoue, Hiromasa; Kamphausen, Thomas; Bajanowski, Thomas; Trübner, Kurt
2011-01-01
A 76-year-old male suffering from nephrolithiasis developed a shock syndrome 5 days after extracorporal shock wave lithotripsy (ESWL). CT scan of the abdomen showed massive haemorrhage around the right kidney. Although nephrectomy was performed immediately, the haemorrhage could not be controlled. Numerous units of erythrocytes were transfused, but the patient died. The autopsy revealed massive retroperitoneal haemorrhage around the right kidney. The kidney showed a subcapsular haematoma and a rupture of the capsule. The right renal artery was dissected. The inferior vena cava was lacerated. Accordingly, a hemorrhagic shock as the cause of death was determined, which might mainly have resulted from the laceration of the inferior vena cava due to ESWL. ESWL seems to be a relatively non-invasive modality, but one of its severe complications is perirenal hematoma. The injuries of the blood vessels might have been caused by excessive shock waves. Subsequently, anticoagulation therapy had been resumed 3 days after EWSL, which might have triggered the haemorrhage. Physicians should note that a haemorrhage after an ESWL can occur and they should pay attention to the postoperative management in aged individuals especially when they are under anticoagulation therapy.
Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.
Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji
2018-06-01
To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.
Left-sided and duplicate inferior vena cava: a case series and review.
Ang, Wee Choen; Doyle, Terry; Stringer, Mark D
2013-11-01
Left-sided and duplicate inferior vena cava (IVC) are two major anatomical variants within the spectrum of IVC malformations, both of which are developmental abnormalities of the supracardinal veins. Four clinical cases are described to highlight the computed tomographic appearances of these vascular malformations and provide novel data on venous dimensions. A systematic review of the recent literature (2000-2011) was conducted focusing on the anatomy, demographics, and associated pathology (congenital and acquired) of isolated left-sided and duplicate IVC. A total of 73 relevant articles were retrieved, consisting of case reports and small case series. The prevalence of left-sided IVC is about 0.1-0.4% and that for duplicate IVC about 0.3-0.4%; both anomalies show a slight male preponderance. In each condition, there are documented variations in the course and tributaries of the IVC. The clinical importance of these anomalies lies in three principal areas: the potential for misdiagnosis on imaging; technical difficulties during retroperitoneal surgery (particularly abdominal aortic aneurysm repair and live donor nephrectomy); and their significance in relation to the etiology and management of venous thromboembolism. Copyright © 2012 Wiley Periodicals, Inc.
Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi
2013-09-01
There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.
Endovascular recanalization of a port catheter-associated superior vena cava syndrome.
Tonak, Julia; Fetscher, Sebastian; Barkhausen, Jörg; Goltz, Jan Peter
2015-01-01
Superior vena cava (SVC) syndrome owing to benign etiology is rare and endovascular techniques have been advocated as the treatment of choice. We report a case of endovascular revascularization of a port catheter-associated complete occlusion of the SVC with reversed flow in the azygos vein. In this setting using a sheath in combination with its dilatator to pass the occlusion of the SVC after neither a diagnostic catheter nor a PTA balloon would pass the lesion may be a valid option. A dual venous approach was established using the right common femoral vein and an indwelling port catheter in the right cephalic vein to dilate and stent the lesion. Finally, a port may be implanted after the revascularization had been successful. Passage through the port catheter-associated occlusion of the SVC was only possible by use of the sheath in combination with its dilatator. A dual venous access by the femoral approach and the indwelling central catheter is helpful in treating a SVC occlusion. Long-term central venous catheters may cause SVC syndrome, especially with a catheter tip located too far cranially. An endovascular revascularization of a complete occlusion of the SVC represents the therapy of choice.
Advanced Technologies in Trauma Critical Care Management
2012-01-01
CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is
Thoracoscopic Surgery for Partial Anomalous Pulmonary Venous Connection with Dual Drainage.
Fuchigami, Tai; Gabe, Atsushi; Takahashi, Kazuhiro; Nishioka, Masahiko; Akashige, Toru; Nagata, Nobuhiro
2015-10-01
We report our technique for thoracoscopic surgery for a 15-year-old female (body weight, 59 kg) diagnosed with partial anomalous pulmonary venous connection with dual drainage. A large anomalous right lower pulmonary vein (RLPV) was drained into the inferior vena cava and left atrium, along with thoracoscopic ligation and clipping of RLPV and some anomalous hepatic veins. © 2015 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Hill, Brent J. F.; Goodman, Ian; Moran, William M.
2011-01-01
Most undergraduate physiology texts describe veins simply as reservoirs for blood and conduits for return of blood to the heart. This article describes a laboratory exercise that can be performed by students to demonstrate that veins are much more than reservoirs and conduits for blood flow: they possess a dynamic rhythmic contraction. In this…
Ferrada, Paula; Vanguri, Poornima; Anand, Rahul J; Whelan, James; Duane, Therese; Aboutanos, Michel; Malhotra, Ajai; Ivatury, Rao
2013-01-01
Limited transthoracic echocardiogram (LTTE) has been introduced as a technique to direct resuscitation in intensive care unit (ICU) patients. Our hypothesis is that LTTE can provide meaningful information to guide therapy for hypotension in the trauma bay. LTTE was performed on hypotensive patients in the trauma bay. Views obtained included parasternal long and short, apical, and subxyphoid. Results were reported regarding contractility (good vs. poor), fluid status (flat inferior vena cava [hypovolemia] vs. fat inferior vena cava [euvolemia]), and pericardial effusion (present vs. absent). Need for surgery, ICU admission, Focused Assessment with Sonography for Trauma examination results, and change in therapy as a consequence of LTTE findings were examined. Data were collected prospectively to evaluate the utility of this test. A total of 148 LTTEs were performed in consecutive patients from January to December 2011. Mean age was 46 years. Admission diagnosis was 80% blunt trauma, 16% penetrating trauma, and 4% burn. Subxyphoid window was obtained in all patients. Parasternal and apical windows were obtained in 96.5% and 11%, respectively. Flat inferior vena cava was associated with an increased incidence of ICU admission (p < 0.0076) and therapeutic operation (p < 0.0001). Of the 148 patients, 27 (18%) had LTTE results indicating euvolemia. The diagnosis in these cases was head injury (n = 14), heart dysfunction (n = 5), spinal shock (n = 4), pulmonary embolism (n = 3), and stroke (n = 1). Of the patients, 121 had LTTE results indicating hypovolemia. Twenty-eight hypovolemic patients had a negative or inconclusive Focused Assessment with Sonography for Trauma examination finding (n = 18 penetrating, n = 10 blunt), with 60% having blood in the abdomen confirmed by surgical exploration or computed tomographic scan. Therapy was modified as a result of LTTE in 41% of cases. Strikingly, in patients older than 65 years, LTTE changed therapy in 96% of cases. LTTE is a useful tool to guide therapy in hypotensive patients in the trauma bay. Diagnostic study, level III.
Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.
Satyapal, K S
1999-10-01
Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral level of entry of renal veins into IVC in foetuses. These findings are clinically important for the angiographer, catheter design, and planning porto-renal shunt procedures. Copyright 1999 Wiley-Liss, Inc.
SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitcham, T; Bouchard, R; Melancon, A
Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic amore » human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.« less
McElhinney, Doff B; Marx, Gerald R; Newburger, Jane W
2011-01-01
Published case reports suggest that congenital portosystemic venous connections (PSVC) and other abdominal venous anomalies may be relatively frequent and potentially important in patients with polysplenia syndrome. Our objective was to investigate the frequency and range of portal and other abdominal systemic venous anomalies in patients with polysplenia and inferior vena cava (IVC) interruption who underwent a cavopulmonary anastomosis procedure at our center, and to review the published literature on this topic and the potential clinical importance of such anomalies. Retrospective cohort study and literature review were used. Among 77 patients with heterotaxy, univentricular heart disease, and IVC interruption who underwent a bidirectional Glenn and/or modified Fontan procedure, pulmonary arteriovenous malformations were diagnosed in 33 (43%). Bilateral superior vena cavas were present in 42 patients (55%). Despite inadequate imaging in many patients, a partial PSVC, dual IVCs, and/or renal vein anomalies were detected in 15 patients (19%). A PSVC formed by a tortuous vessel running from the systemic venous system to the extrahepatic portal vein was found in six patients (8%). Abdominal venous anomalies other than PSVC were documented in 13 patients (16%), including nine (12%) with some form of duplicated IVC system, with a large azygous vein continuing to the superior vena cava and a parallel, contralateral IVC of similar or smaller size, and seven with renal vein anomalies. In patients with a partial PSVC or a duplicate IVC that connected to the atrium, the abnormal connection allowed right-to-left shunting. PSVC and other abdominal venous anomalies may be clinically important but under-recognized in patients with IVC interruption and univentricular heart disease. In such patients, preoperative evaluation of the abdominal systemic venous system may be valuable. More data are necessary to determine whether there is a pathophysiologic connection between the polysplenia variant of heterotaxy, PSVC, and cavopulmonary anastomosis-associated pulmonary arteriovenous malformations. © 2011 Copyright the Authors. Congenital Heart Disease © 2011 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Wen, E-mail: wenzhangxiao@126.com; Yan, Zhiping, E-mail: Yan.zhiping@zs-hospital.sh.cn; Luo, Jianjun, E-mail: luo.jianjun@zs-hospital.sh.cn
Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy,more » and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model.« less
Litwin, Robert J; Huang, Steven Y; Sabir, Sharjeel H; Hoang, Quoc B; Ahrar, Kamran; Ahrar, Judy; Tam, Alda L; Mahvash, Armeen; Ensor, Joe E; Kroll, Michael; Gupta, Sanjay
2017-09-01
Our primary purpose was to assess the impact of an inferior vena cava filter retrieval algorithm in a cancer population. Because cancer patients are at persistently elevated risk for development of venous thromboembolism (VTE), our secondary purpose was to assess the incidence of recurrent VTE in patients who underwent filter retrieval. Patients with malignant disease who had retrievable filters placed at a tertiary care cancer hospital from August 2010 to July 2014 were retrospectively studied. A filter retrieval algorithm was established in August 2012. Patients and referring physicians were contacted in the postintervention period when review of the medical record indicated that filter retrieval was clinically appropriate. Patients were classified into preintervention (August 2010-July 2012) and postintervention (August 2012-July 2014) study cohorts. Retrieval rates and clinical pathologic records were reviewed. Filter retrieval was attempted in 34 (17.4%) of 195 patients in the preintervention cohort and 66 (32.8%) of 201 patients in the postintervention cohort (P < .01). The median time to filter retrieval in the preintervention and postintervention cohorts was 60 days (range, 20-428 days) and 107 days (range, 9-600 days), respectively (P = .16). In the preintervention cohort, 49 of 195 (25.1%) patients were lost to follow-up compared with 24 of 201 (11.9%) patients in the postintervention cohort (P < .01). Survival was calculated from the date of filter placement to death, when available. The overall survival for patients whose filters were retrieved was longer compared with the overall survival for patients whose filters were not retrieved (P < .0001). Of the 80 patients who underwent successful filter retrieval, two patients (2.5%) suffered from recurrent VTE (n = 1 nonfatal pulmonary embolism; n = 1 deep venous thrombosis). Both patients were treated with anticoagulation without filter replacement. Inferior vena cava filter retrieval rates can be significantly increased in patients with malignant disease with a low rate (2.5%) of recurrent VTE after filter retrieval. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kutterolf, S.; Schindlbeck, J. C.; Anselmetti, F. S.; Ariztegui, D.; Brenner, M.; Curtis, J.; Schmid, D.; Hodell, D. A.; Mueller, A.; Pérez, L.; Pérez, W.; Schwalb, A.; Frische, M.; Wang, K.-L.
2016-10-01
Lake Petén Itzá, northern Guatemala, lies within a hydrologically closed basin in the south-central area of the Yucatán Peninsula, and was drilled under the auspices of the International Continental Scientific Drilling Program (ICDP) in 2006. At 16°55‧N latitude, the lake is ideally located for study of past climate and environmental conditions in the Neotropical lowlands. Because of its great depth (>160 m), Lake Petén Itzá has a record of continuous sediment accumulation that extends well into the late Pleistocene. A key obstacle to obtaining long climate records from the region is the difficulty of establishing a robust chronology beyond ∼40 ka, the limit of 14C dating. Tephra layers within the Lake Petén Itzá sediments, however, enable development of age/depth relations beyond 40 ka. Ash beds from large-magnitude, Pleistocene-to-Holocene silicic eruptions of caldera volcanoes along the Central American Volcanic Arc (CAVA) were found throughout drill cores collected from Lake Petén Itzá. These ash beds were used to establish a robust chronology extending back 400 ka. We used major- and trace-element glass composition to establish 12 well-constrained correlations between the lacustrine tephra layers in Lake Petén Itzá sediments and dated deposits at the CAVA source volcanoes, and with their marine equivalents in eastern Pacific Ocean sediments. The data also enabled revision of eight previous determinations of erupted volumes and masses, and initial estimates for another four eruptions, as well as the designation of source areas for 14 previously unknown eruptions. The new and revised sedimentation rates for the older sediment successions identify the interglacial of MIS5a between 84 and 72 ka, followed by a stadial between 72 and 59 ka that corresponds to MIS4. We modified the age models for the Lake Petén Itzá sediment sequences, extended the paleoclimate and paleoecological record for this Neotropical region to ∼400 ka, and determined the magnitude and timing of CAVA eruptions.
Brown, Joshua; Talbert, Jeffery; Pennington, Ryan; Han, Qiong; Raissi, Driss
2018-01-01
Retrieval of inferior vena cava filters (IVCFs) is important to decrease the long-term risk of complications associated with indwelling devices. Our hospital experienced low retrieval rates and implemented a low-cost intervention and evaluation for quality improvement. The working hypothesis was that a simple, mailed letter intervention could increase retrieval rates by increasing patient and primary care provider knowledge of the need for retrieval. For all prospective patients who received a retrievable IVCF during the intervention period from January 1, 2014 to February 29, 2016, patients and their primary care providers were mailed letters encouraging contact with the clinic for evaluation of eligibility for retrieval. The main outcome was retrieval of the IVCF if clinically indicated with a secondary outcome of time-to-retrieval. A pre-intervention control group from October 1, 2011 to December 31, 2013 was used to evaluate the impact of the intervention. Competing risks, time-to-event analysis was used to compare the pre- and post-intervention period retrieval rates correcting for patients who died during follow-up. Between the pre- and post-intervention periods, crude retrieval rates increased from 4.4% to 8.1% with a 12-fold change at comparable time points. The time-to-retrieval in the pre-intervention period was a mean (SD) of 503 (207) days with a median (IQR) of 505 (301-742). In the post-intervention period, time-to-retrieval was a mean (SD) of 119 (83) days and with median (IQR) of 128 (38-164) days. This low-cost intervention significantly increased retrieval rates in a single clinic. However, retrieval rates remain low and can be further improved. Ongoing interventions, including improved patient follow-up and physician education, are being implemented to further improve retrieval and use of inferior vena cava filters. Implanting clinics should implement quality improvement initiatives to improve patient care and follow-up with IVCFs to ensure retrievals occur once clinically relevant in order to minimize long-term complications.
Lei, Wenjia; Fan, Miao; Wang, Meilian; Wang, Yu; Sun, Wei; Sun, Xue; Zhang, Ying
2018-05-02
Foramen ovale (FO) valve with a shape or motion abnormality is frequently detected during routine obstetric ultrasonic examinations. However, the hemodynamics mechanism of this entity remains unclear. The purpose of the study is to determine the relevance of interatrial communication restriction and resultant morphological modifications. We reviewed the echocardiographic records of fetuses with isolated abnormal FO valve evaluated between January of 2010 and december of 2016. The size (DFO) of the FO orifice, opening angle (α) of the FO valve, and dimensions of cardiac chambers, FO channel outlet (DOUT) and inferior vena cava (DIVC) were measured. We evaluated their (DFO, DOUT, α) relationships to the diameters of RA and DIVC. Five hundred and seventy normal fetuses were selected to establish the normal range of the DOUT/DIVC ratio so as to provide a criterion for restriction. An abnormal FO valve was identified in 89 fetuses without congenital heart disease, with restriction noted in 62 fetuses (45 fetuses with RA dilatation, 12 fetuses with RA and RV dilatation, and 5 fetuses with no RA dilatation). There were no significant correlations between RA/LA and DFO/DIVC, RA/ LA and α. RA/LA was negatively correlated with DOUT/DIVC (R2=0.97, p<0.01). For a fetus with an abnormal FO valve, right heart dilatation could be considered as an indicator of interatrial communication restriction, which could be assessed by evaluating the FO channel outlet. The degree of right atrium dilatation indicates the severity of the restriction.
Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei
2018-05-30
To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.
Paganini, Matteo; Bondì, Michela; Rubini, Alessandro
2017-12-01
Ultrasound imaging is a widely used diagnostic technique, whose integration in medical education is constantly growing. The aim of this study was to evaluate chest ultrasound usefulness in teaching respiratory system physiology, students' perception of chest ultrasound integration into a traditional lecture in human physiology, and short-term concept retention. A lecture about respiratory physiology was integrated with ultrasound and delivered to third-year medical students. It included basic concepts of ultrasound imaging and the physiology of four anatomic sectors of the body of a male volunteer, shown with a portable ultrasound device (pleural sliding, diaphragmatic movement, inferior vena cava diameter variations, cardiac movements). Students' perceptions of the integrated lecture were assessed, and attendance recorded. After 4 mo, four multiple-choice questions about respiratory physiology were administered during the normal human physiology examinations, and the results of students who attended the lesson and those of who did not were compared. One hundred thirty-four students attended the lecture. Most of them showed encouragement for the study of the subject and considered the ultrasound integrated lecture more interesting than a traditional one and pertinent to the syllabus. Exposed students achieved a better score at the examination and committed less errors than did nonexposed students. The chest ultrasound integrated lecture was appreciated by students. A possible association between the exposure to the lecture and short-term concept retention is shown by better performances of the exposed cohort at the examination. A systematic introduction of ultrasound into physiology traditional teaching will be promoted by the Ultrasound-Based Medical Education movement. Copyright © 2017 the American Physiological Society.
Congenital absence of the portal vein in a cat
Holloway, Andrew; Groot, Louise; van der Schaaf, Klaartje
2018-01-01
Case summary A 9-month-old female neutered domestic shorthair cat presented with a history of episodic ptyalism, lethargy and abnormal behaviour. The clinical signs together with elevated pre- and post-prandial bile acid concentrations were consistent with hepatic encephalopathy (HE). In the absence of a portosystemic shunt (PSS) on abdominal ultrasound, medical management of HE was established with a protein-restricted diet and lactulose and the neurological signs resolved. Following an episode of acute vomiting and haemorrhagic diarrhoea at 19 months of age abdominal ultrasonography was repeated. The portal vein could not be demonstrated ultrasonographically; instead, portal vein tributaries were tortuous and communicated with the caudal vena cava (CdVC) at the level of the left kidney. CT angiography (CTA) confirmed the absence of the portal vein. CTA demonstrated the tortuous terminations of the portal tributaries, and several systemic veins, draining into the CdVC via a large-diameter paracaval vessel at the level of the left kidney. Gastrointestinal signs were stabilised and medical management for HE of a protein-restricted diet and lactulose was re-established. Relevance and novel information Congenital absence of the portal vein has not been described previously in the cat and should be considered in cats presenting with signs suggestive of a PSS and HE. The portal vein in the cat can be demonstrated using ultrasound, but complex congenital vascular malformations of the portal or systemic abdominal veins should be characterised using CTA and further distinguished from other vascular anomalies that may present with similar ultrasonographic features. PMID:29372068
Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas
2010-01-01
This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.
Günther Tulip inferior vena cava filter retrieval using a bidirectional loop-snare technique.
Ross, Jordan; Allison, Stephen; Vaidya, Sandeep; Monroe, Eric
2016-01-01
Many advanced techniques have been reported in the literature for difficult Günther Tulip filter removal. This report describes a bidirectional loop-snare technique in the setting of a fibrin scar formation around the filter leg anchors. The bidirectional loop-snare technique allows for maximal axial tension and alignment for stripping fibrin scar from the filter legs, a commonly encountered complication of prolonged dwell times.
Deformation Cycling of a Ti - Ni Alloy with Superelasticity Effect Applied in Cardiology
NASA Astrophysics Data System (ADS)
Kaputkin, D. E.; Morozova, T. V.
2014-07-01
The study concerns the effect of the conditions and of the force of loading experienced by an implanted device from a Ti - Ni alloy during its transfer to the working zone, for example, in endoscopic implantation into the coronary sinus of the greater vena cava of heart. It is shown that preliminary deformation cycling (10 - 15 cycles) stabilizes the set of mechanical properties of the alloy.
Persistent Organic Pollutants in Serum and Several Different Fat Compartments in Humans
2011-01-01
vena cava; A: aorta; P: pancreas; K: kidney; L: liver; S: stomach and spleen; C: colon; U: uterus; B: bladder; P: prostate. flame retardants , and...such as dioxins/furans, polychlori- nated biphenyls (PCBs), chlorinated pesticides, brominated Report Documentation Page Form ApprovedOMB No. 0704...perfluorinated compounds. Because of chlorine, bromine , or fluoride groups on the hydrocarbon rings or chains, these substances are resistant to degradation
Journal of Special Operations Medicine. Volume 9, Edition 3, Summer 2009
2009-01-01
consist of a central venous catheter placed within the in- ferior vena cava. Cooled saline is pushed through the catheter balloons, which are in...water immersion has both cardio- vascular and pulmonary effects. Increased venous re- turn leads to central pooling of blood, which thereby...Induced Pulmonary Edema (SIPE) 49 11. Norsk P, Bonde-Petersen F, Warberg J. (1986). Central venous pressure and plasma arginine vasopressin in man
Medical Simulation for Trauma Management.
1997-10-01
the inferior mesenteric vein and identify the aorta. Indications for surgical exploration of major trauma (McAninch and Carroll (1989...aorta. (5) Vascular control is obtained by clamping the renal vein and artery at their origins from the vena cava and the aorta, (mistake possible...as if they are being miniaturized and injected into the heart’s left atrium . Their mission, in Page 21 order to save the patient, is to maneuver
USAFSAM Review and Analysis of Radiofrequency Radiation Bioeffects Literature. Fifth Report.
1985-03-01
exteriorized between the scapulae. The tip of the catheter was positioned at the juncture between the superior and inferior venae cavae . With this preparation...other than in connection with a definitely Government-related procure- ment, the United States Government incurs no responsibility or any obligation...Between experimental sessions, Frey and Seifert measured the power density with a quarter-wave dipole connected to a commercial thermistor and power meter
2007-10-01
The atrial chamber that is connected to the inferior vena cava is typically the right atrium . The pulmonary veins typically empty into the left ...only “a left chest wall 6 cm scar consistent with surgical history.” The screening chest x-ray is presented below (Fig 1A). Technical limitations...Cardiac MRI images further define the internal cardiac anatomy. On a coronal bright blood MRI image (Fig. 1B; LA = left atrium ; LPA = left
Robot-assisted laparoscopic reconstruction of retrocaval ureter: description and video of technique.
LeRoy, Timothy J; Thiel, David D; Igel, Todd C
2011-05-01
Ureteral obstruction secondary to retrocaval ureter is rarely reported in the urologic literature. Symptomatic retrocaval ureters usually present in the 3rd and 4th decade of life. Standard treatment involves ureteroureterostomy approximating the ureter anterior to the vena cava. We describe the initial presentation, imaging, port placement, and operative technique including video presentation of a robot-assisted laparoscopic repair of a retrocaval ureter.
Venous obstruction in permanent pacemaker patients: an isotopic study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pauletti, M.; Di Ricco, G.; Solfanelli, S.
1981-01-01
Isotope venography was used to study the venous circulation proximal to the superior vena cava in two groups of pacemaker patients, one with a single endocavitary electrode and the other with multiple pacing catheters. A control group of patients without pacemakers was also studied. Numerous abnormalities were found, especially in the group with multiple electrodes. These findings suggest that venous obstruction is a common complication of endocardial pacing.
Hagisawa, Kohsuke; Saito, Akihiro; Kinoshita, Manabu; Fujie, Toshinori; Otani, Naoki; Shono, Satoshi; Park, Young-Kwang; Takeoka, Shinji
2013-07-01
To investigate the efficacy of multioverlapping therapy using a polysaccharide nanosheet having 75-nm thickness for sealing and stopping massive venous hemorrhage. The hydrostatic durability of the polysaccharide nanosheet was evaluated in vitro when secured to an incised silicon tube. For in vivo studies, the inferior vena cava (IVC) of rabbits was cut longitudinally, and multiple polysaccharide nanosheets were overlapped onto the injured IVC. The mechanical hydrostatic durability of the nanosheets was gradually augmented by an increasing number of multilayered nanosheets in vitro. This durability was saturated at 80 ± 6 mm Hg by four layers of nanosheets, which was robust enough to seal injured vessel walls of the large IVC. Multioverlapping therapy using nanosheets effectively sealed and stopped bleeding from the injured IVC in vivo. One month later, no inflammatory tissue response was observed around the nanosheet attachment sites of the IVC, while conventional suturing repair in control rabbits showed a severe inflammatory response around the sutured area. The multioverlapping therapy using the polysaccharide nanosheets will effectively stop massive venous bleeding without adverse effects in the immediate or chronic postoperative setting. Copyright © 2013 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Maciel, James D; Plurad, David; Gifford, Edward; deVirgilio, Christian; Koopmann, Matt; Neville, Angela; Putnam, Brant; Kim, Dennis Y
2015-10-01
Inferior vena cava (IVC) injuries are associated with significant morbidity and mortality. To identify clinical factors associated with mortality in patients undergoing operative intervention for penetrating IVC injuries, a retrospective review of 98 patients was performed, excluding blunt injuries (n = 20) and deaths before surgery (n = 16). The overall mortality was 58 per cent. Nonsurvivors more commonly presented with hypotension (50% vs 23%, P = 0.03) and underwent resuscitative thoracotomy more frequently (42% vs 4%, P = 0.01). Retrohepatic injuries were more common among nonsurvivors (P = 0.04). There was no difference in the use of ligation (7% vs 17%, P = 0.29) or the massive transfusion protocol (35% vs 25%, P = 0.41). On multivariate analysis, after controlling for mechanism of injury, admission hypotension, Glasgow Coma Scale score , preoperative cumulative fluids, resuscitative thoracotomy , absence of spontaneous tamponade, and location of IVC injury, the only independent predictor of mortality was the absence of spontaneous tamponade at the time of laparotomy (odds ratio = 5.4, 95% confidence interval: 1.11-25.95; P = 0.04). Penetrating IVC injuries continue to be associated with a high mortality, particularly among patients with free intraabdominal hemorrhage at laparotomy. Large multicenter studies are required to define the optimal resuscitative and operative management techniques in these severely injured patients.
Robotic-Assisted Inferior Vena Cava Filter Retrieval.
Owji, Shahin; Lu, Tony; Loh, Thomas M; Schwein, Adeline; Lumsden, Alan B; Bismuth, Jean
2017-01-01
Although anticoagulation remains the mainstay of therapy for patients with venous thromboembolism, guidelines recommend the use of inferior vena cava (IVC) filters in those who fail anticoagulation or have contraindications to its use. Short-term use of filters has proven effective in reducing the rate of pulmonary embolism. However, their extended use is associated with a variety of complications such as thrombosis, filter migration, or caval perforation, thus making a case for timely filter retrieval. This is the case of a 68-year-old female with a history of chronic oral anticoagulation use for multiple deep venous thrombi (DVT) and pulmonary emboli (PE) who required cervical and thoracic spinal intervention for spondylosis and foramina stenosis. Given her increased risk of recurrent DVT and PE perioperatively, we elected to place a Cook Celect ™ IVC filter (Cook Medical, Bloomington, IN) after oral anticoagulation was stopped for the procedure. Her treatment course was prolonged due to wound-healing complications. We elected to use the Magellan Robotic Catheter System (Hansen Medical, Mountain View, CA) for filter retrieval when she presented 6 months later with caval perforation from the filter struts. With its ease of use, superior mechanical stability, and maneuverability, robot-assisted IVC filter retrieval may be a safer and more reliable substitute for traditional navigation techniques when presented with challenging filter retrievals.
Colon perforation and Budd-Chiari syndrome in Behçet's disease.
Baş, Yılmaz; Güney, Güven; Uzbay, Pınar; Zobacı, Ethem; Ardalı, Selin; Özkan, Ayşegül Taylan
2015-05-02
Behçet's disease is a chronic inflammatory disease involving multiple systems, with vasculitis being the most important pathological feature. Multiple colon perforations are thought to be secondary to vasculitis and they occur in patients with ulcers. These may be encountered within the entire colon but most commonly in the ileocecal region. Intestinal perforation and Budd-Chiari syndrome are infrequent in Behçet's disease, and are associated with high mortality and morbidity. Budd-Chiari syndrome results from occlusion of either hepatic veins or adjacent inferior vena cava, or both. We report a patient with Behçet's disease having multiple perforations in the transverse colon, descending colon, and sigmoid colon. The patient also had Budd-Chiari syndrome due to inferior vena cava thrombosis extending into the right and middle hepatic vein. Our observations are presented with a review of the literature. In Behçet's disease, treatment of colon perforation necessitates urgent surgery, whereas management of Budd-Chiari syndrome is directed towards the underlying cause. Behçet's disease, as a chronic multisystemic disease with various forms of vasculitis, is resistant to medical and surgical treatment. Prognosis is worse in Behçet's disease with colon perforation than that in Budd-Chiari syndrome alone.
Prenatal diagnosis of atrial isomerism in the Korean population
Lee, Mi-Young; Shim, Jae-Yoon; Lee, Pil-Ryang; Lee, Byong Sop; Kim, Ellen Ai-Rhan; Kim, Young-Hwue; Park, Jeong-Jun; Yun, Tae-Jin; Kim, Ahm
2014-01-01
Objective To report our experiences in the prenatal diagnosis of atrial isomerism and postnatal outcomes. Methods A total of 80 fetuses prenatally diagnosed with atrial isomerism were retrospectively analyzed between 1999 and 2011 at a single institution. Results Of 43 fetuses with prenatally diagnosed right atrial isomerism (RAI), 40 cases were analyzed. The diagnostic accuracy was 93%. The main intracardiac anomalies in RAI were atrioventricular septal defect (AVSD), abnormal pulmonary venous connection, bilateral superior vena cava (BSVC), and pulmonary atresia. Among 28 live births, three infants were lost to follow up, and the overall survival rate was 60%. Of 37 fetuses with prenatally diagnosed left atrial isomerism (LAI), 35 were evaluated. The diagnostic accuracy was 97%. The main intracardiac anomalies in LAI were ventricular septal defect, BSVC, AVSD, double outlet right ventricle, and bradyarrhythmia. Among seven patients with bradyarrhythmia, only one showed a complete atrioventricular block. All fetuses had an interrupted inferior vena cava with azygous continuation. The overall survival rate was 90%. Conclusion Our study confirms the previous findings of fetal atrial isomerism. We also demonstrates a much lower prevalence of AVSD and complete heart block in LAI and a better survival rate in RAI. Although the postnatal outcomes for RAI were worse than those for LAI, successful postnatal surgery with active management improved the survival rate. PMID:24883290
Pussepitiya, Kumari; Samarasinghe, Bandula; Wickramasinghe, Nuwan
2016-01-01
Introduction. Vitelline artery remnants are rare causes of intra-abdominal bands leading to bowel obstruction. These bands may be associated with Meckel's diverticulum. Double inferior vena cava (IVC) is a rare presentation and is usually identified incidentally. Case Presentation. A sixty-year-old male presented with progressive vomiting for five days and he was clinically diagnosed with intestinal obstruction. Plain X-ray abdomen showed evidence of small bowel obstruction. CT scan of the abdomen revealed dilated small bowel loops with a small outpouching in the distal ileum with a band like structure attached to it. In the CT, left sided patent IVC draining into the left renal vein was identified. Left external iliac vein was in continuity with the left IVC. Left internal iliac vein was draining into the right IVC. Exploratory laparotomy revealed a Meckel's diverticulum with a band identified as the vitelline remnant attached to its apex and inserting at the anterior abdominal wall near the umbilicus. Discussion. Meckel's diverticulum with vitelline bands, although rare, should be borne in mind in adult patients with intestinal obstruction. Identification of this anomaly can be difficult in imaging studies. Presence of double IVC should be mentioned in the imaging findings to prevent possible catastrophic complications during surgery. PMID:27843667
Etiology and VTE risk factor distribution in patients with inferior vena cava thrombosis.
Linnemann, Birgit; Schmidt, Henriette; Schindewolf, Marc; Erbe, Matthias; Zgouras, Dimitrios; Grossmann, Ralf; Schambeck, Christian; Lindhoff-Last, Edelgard
2008-01-01
Inferior vena cava (IVC) thrombosis is a rare event and data detailing the underlying etiology are scarce. Therefore, we reviewed all available cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described the prevalence of VTE risk factors and other conditions contributing to IVC thrombosis development. 53 patients (35 F, 18 M) with IVC thrombosis aged 12 to 79 years were identified. 40 patients (75.5%) developed thrombosis under the age of 45. Local problems, such as IVC anomalies or external venous compression, contributed to the development of thrombosis in 12 cases (22.6%). Lupus anticoagulants (10.9 vs. 2.3%, p=0.013) and malignoma (17.0 vs. 6.4%, p=0.023) were more prevalent in IVC thrombosis patients compared to 265 age and sex matched controls with isolated lower extremity DVT. No difference was identified with regard to inherited thrombophilia or other known VTE risk factors. Symptomatic pulmonary embolism (PE) occurred in 32.1% of IVC thrombosis patients compared to 15.2% of controls (p=0.005). Local problems such as IVC anomalies and external venous compression, malignancy and the presence of lupus anticoagulants contribute to the risk of IVC thrombosis. The risk of symptomatic pulmonary embolism in the acute setting is high.
Yap, Shook H; Anania, Nicole; Alboliras, Ernerio T; Lilien, Lawrence D
2009-04-01
The newborn can experience two types of differential cyanosis (DC). The common type of DC occurs when oxygen saturation in the right hand is greater than in the foot. The second type of DC, reversed differential cyanosis (RDC), occurs when oxygen saturation is lower in the right hand than in the foot. This phenomenon is observed in transposition of the great arteries (TGA) with patent ductus arteriosis (PDA) and elevated pulmonary vascular resistance or in TGA with PDA and preductal aortic interruption or coarctation. This report describes a case of RDC not previously described involving an infant with supracardiac total anomalous pulmonary venous connection (TAPVC). In supracardiac TAPVC, RDC results from streaming of highly saturated superior vena cava (SVC) blood into the right ventricle, out the main pulmonary artery, through a PDA, and to the descending aorta, with streaming of more desaturated blood from the inferior vena cava (IVC) into the left atrium across the atrial septal defect (ASD)/foramen ovale. Therefore, as part of a neonatal examination to rule out congenital heart disease (CHD), simultaneous pre- and postductal oxygen saturations should be documented. The presence of RDC should initiate immediate full cardiac evaluation for CHD. Supracardiac TAPVC should be included in the differential diagnosis if RDC is observed.
Congenital abnormalities of the inferior vena cava presenting clinically in adolescent males.
Halparin, Jessica; Monagle, Paul; Newall, Fiona
2015-04-01
Congenital anatomic abnormality of the inferior vena cava (IVC) is an important risk factor for the development of spontaneous proximal lower extremity deep vein thrombosis (DVT) in young adults. The incidence of DVT associated with congenital IVC anomalies in paediatric populations has not been described, and the implications of IVC anomalies for treatment and outcomes of DVT are unknown. This study reports a series of five adolescent males with spontaneous lower extremity DVTs and underlying congenital IVC abnormalities. Cases were identified by searching the institutional database of patients treated with anticoagulation for venous thromboembolism at a tertiary children's hospital. The demographics, clinical presentations, imaging findings, treatment courses, and outcomes are described. All cases occurred in males, and accounted for approximately twenty percent of adolescent males presenting with DVT. IVC abnormality is likely an under-recognized risk factor for DVT in this age group, and detailed vascular imaging should be pursued in adolescents with spontaneous proximal lower extremity DVT when initial ultrasonography does not delineate the proximal clot extent. Management requires individual risk-benefit assessment in the context of providing developmentally appropriate care. Further research is required to establish long-term outcomes and determine optimal treatment strategies. Copyright © 2015 Elsevier Ltd. All rights reserved.
Cho, Suengmok; Han, Daeseok; Kim, Seon-Bong; Yoon, Minseok; Yang, Hyejin; Jin, Young-Ho; Jo, Jinho; Yong, Hyeim; Lee, Sang-Hoon; Jeon, You-Jin; Shimizu, Makoto
2012-01-01
Marine plants have been reported to possess various pharmacological properties; however, there have been few reports on their neuropharmacological effects. Terrestrial plants have depressive effects on the central nervous system (CNS) because of their polyphenols which make them effective as anticonvulsants and sleep inducers. We investigated in this study the depressive effects of the polyphenol-rich brown seaweed, Ecklonia cava (EC), on CNS. An EC enzymatic extract (ECEE) showed significant anticonvulsive (>500 mg/kg) and sleep-inducing (>500 mg/kg) effects on the respective mice seizure induced by picrotoxin and on the mice sleep induced by pentobarbital. The phlorotannin-rich fraction (PTRF) from ECEE significantly potentiated the pentobarbital-induced sleep at >50 mg/kg. PTRF had binding activity to the gamma aminobutyric acid type A (GABA(A))-benzodiazepine (BZD) receptors. The sleep-inducing effects of diazepam (DZP, a well-known GABA(A)-BZD agonist), ECEE, and PTRF were completely blocked by flumazenil, a well-known antagonist of GABA(A)-BZD receptors. These results imply that ECEE produced depressive effects on CNS by positive allosteric modulation of its phlorotannins on GABA(A)-BZD receptors like DZP. Our study proposes EC as a candidate for the effective treatment of neuropsychiatric disorders such as anxiety and insomnia.
Ghanney, Efe C; Cavallo, Jaime A; Levin, Matthew A; Reddy, Ramachandra; Bander, Jeffrey; Mella, Maria; Stone, Joanne; Schwartz, Myron; Haines, Kenneth; Gidwani, Umesh; Mehrazin, Reza
2017-12-01
Only one case of renal cell carcinoma (RCC) with inferior vena cava (IVC) tumor thrombus diagnosed and treated during pregnancy has been reported in the literature. In that report, the tumor thrombus extended to the infrahepatic IVC (level II tumor thrombus). In the present case, a 37-year-old woman with lupus anticoagulant antibodies was diagnosed with RCC and IVC tumor thrombus extending to the right atrium (level IV tumor thrombus) at 24 weeks of pregnancy. The fetus was safely delivered by cesarean section at 30 weeks of gestation. At 4 days later, an open right radical nephrectomy and IVC and right atrial thrombectomy were performed on cardiopulmonary bypass (CPB) once the patient's hemodynamic status had been optimized. Fetal and maternal concerns included the risk of a thromboembolic event (due to increased hypercoagulability from pregnancy, active malignancy, and lupus anticoagulant), intraoperative hemorrhage risk (due to extensive venous collaterals and anticoagulation), and fetal morbidity and mortality (due to fetal lung immaturity). Standardized guidelines for treatment of RCC with or without IVC tumor thrombus during pregnancy are unavailable due to the infrequency of such cases. Treatment decisions are therefore individualized and this case report may inform the management of future patients diagnosed with RCC with level IV tumor thrombus during pregnancy.
Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L
2014-09-01
A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
The role of interventional radiology in management of benign and malignant gynecologic diseases.
Yu, Hyeon; Stavas, Joseph M
2013-10-01
This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.
NASA Technical Reports Server (NTRS)
Elliott, Morgan; Martin, David
2015-01-01
For my summer internship project, I organized a pilot study to analyze the effects of a cephalic fluid shift on venous return and right ventricular mechanics to increase right ventricular and venous knowledge. To accomplish this pilot study, I wrote a testing protocol, obtained Institutional Review Board (IRB) approval, completed subject payment forms, lead testing sessions, and analyzed the data. This experiment used -20deg head down tilt (20 HDT) as the ground based simulation for the fluid shift that occurs during spaceflight and compared it to data obtained from the seated and supine positions. Using echocardiography, data was collected for the right ventricle, hepatic vein, internal jugular vein, external jugular vein, and inferior vena cava. Additionally, non-invasive venous pressure measurements, similar to those soon to be done in-orbit, were collected. It was determined that the venous return from below the heard is increased during 20 HDT, which was supported by increased hepatic vein velocities, increased right ventricular inflow, and increased right ventricular strain at 20 HDT relative to seated values. Jugular veins in the neck undergo an increase in pressure and area, but no significant increase in flow, relative to seated values when a subject is tilted 20 HDT. Contrary to the initial expectations based on this jugular flow, there was no significant increase in central venous pressure, as evidenced by no change in Doppler indices for right arterial pressure or inferior vena cava diameter. It is suspected that these differences in pressure are due to the hydrostatic pressure indifference point shifting during tilt; there is a potential for a similar phenomenon with microgravity. This data will hopefully lead to a more in-depth understanding of the response of the body to microgravity and how those relate to the previously mentioned cardiovascular risk of fluid shift that is associated with spaceflight. These results were presented in greater detail to the Cardiovascular Laboratory and the Space Life Science Summer Institute, which helped me prepare for future graduate school research presentations. This internship allowed me to apply and expand the anatomy, physiology, and mechanics information I learned during my undergraduate degree in Biomedical Engineering to the cardiovascular system with the unique zero gravity perspective. Additionally, I was able to develop skills with data analysis techniques involving speckle tracking for ventricular strain and Doppler waveforms for blood velocities. Additionally, I was able to expand upon my previous work in the Cardiovascular Laboratory by writing a literature review on a data analysis project I completed last summer. Ultimately, this internship and venous relationship comparison project provided me with a significant learning experience and additional skill sets, which are applicable to my goals of attaining a Ph.D. in biomedical engineering with a focus on tissue engineering and the cardiovascular system.
[Two-stage hepatectomy for hepatic metastasis and supra renal vena cava reconstruction].
Nicoluzzi, João Eduardo
2012-12-01
Two-stage hepatectomy uses compensatory liver regeneration after a first noncurative hepatectomy to enable a second curative resection. Herein we report the tecnical aspects of the management of a thirty-seven years-old woman with colorectal metastasis to the liver eligible because single resection could not achieve complete treatment, even in combination with chemotherapy, portal embolization, or radiofrequency, but tumors could be totally removed by two sequential resections.
Retro-aortic left renal vein--an anatomic variation description and review of literature.
Suma, H Yekappa; Roopa, Kulkarni
2011-01-01
This study reports the presence of a retro-aortic renal vein on the left side draining into the inferior vena cava. This variation was observed during routine dissection in a female cadaver aged about 55 years. This variation is of importance because of its implications in renal transplantation, renal surgery, vascular surgery, uroradiology and gonadal surgeries. The knowledge of such variations can help the clinicians for its recognition and protection.
Neuropeptides in Experimental Head Injury.
1987-02-28
Harvard Apparatus, Milton, MA). Drugs were administered through a cannula placed in the inferior vena cava via the femoral vein, The femoral artery was...with a slightly flared end was placed in the left atrium via a thoracotomy (see reference 6), and the chest was sutured closed. Page 10 For each CBF...a vortex mixer, microspheres were injected into the left atrium over approximately 30 sec. The injection of this number of microspheres insured that