Inferior Vena Cava Filter Placement and Removal
... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...
Endovascular management of inferior vena cava filter thrombotic occlusion.
Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R
2018-01-01
Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.
Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz
2009-05-01
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen
The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less
Indications, complications and outcomes of inferior vena cava filters: A retrospective study.
Wassef, Andrew; Lim, Wendy; Wu, Cynthia
2017-05-01
Inferior vena cava filters are used to prevent embolization of a lower extremity deep vein thrombosis when the risk of pulmonary embolism is thought to be high. However, evidence is lacking for their benefit and guidelines differ on the recommended indications for filter insertion. The study aim was to determine the reasons for inferior vena cava filter placement and subsequent complication rate. A retrospective cohort of patients receiving inferior vena cava filters in Edmonton, Alberta, Canada from 2007 to 2011. Main outcome was the indication of inferior vena cava filter insertion. Other measures include baseline demographic and medical history of patients, clinical outcomes and filter retrieval rates. 464 patients received inferior vena cava filters. An acute deep vein thrombosis with a contraindication to anticoagulation was the indication for 206 (44.4%) filter insertions. No contraindication to anticoagulation could be identified in 20.7% of filter placements. 30.6% were placed in those with active cancer, in which mortality was significantly higher. Only 38.9% of retrievable filters were successfully retrieved. Inferior vena cava filters were placed frequently in patients with weak or no guideline-supported indications for filter placement and in up to 20% of patients with no contraindication to anticoagulation. The high rates of cancer and the high mortality rate of the cohort raise the possibility that some filters are placed inappropriately in end of life settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
TrapEase inferior vena cava filter placement: use of the subclavian vein.
Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A
2004-01-01
The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access and where combined long-term central venous catheter placement using the subclavian vein is desirable.
Heart block and cardiac embolization of fractured inferior vena cava filter.
Abudayyeh, Islam; Takruri, Yessar; Weiner, Justin B
2016-01-01
A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures. The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process. This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation. Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.
Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications
DeYoung, Elliot; Minocha, Jeet
2016-01-01
Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472
Inferior Vena Cava Filter from Left-Sided Superior Vena Cava
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nair, Sujit, E-mail: drsnnair@hotmail.com; Ettles, Duncan; Robinson, Graham
We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veerapong, Jula; Wahlgren, Carl Magnus, E-mail: carl.wahlgren@karolinska.s; Jolly, Neeraj
The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.
Jiang, Jun; Jiao, Yuanyong; Zhang, Xiwei
2017-10-01
Objectives To perform a meta-analysis of randomized controlled trials assessing the effectiveness of inferior vena cava filters in patients with deep vein thrombosis for preventing pulmonary embolism. Method Relevant randomized controlled trials of inferior vena cava filters for the prevention of pulmonary embolism were identified by searching electronic databases updated in February 2016. Relative risks of recurrent pulmonary embolism, recurrent deep vein thrombosis, and mortality at three months were analyzed. Results Three published randomized controlled trials were included involving a total of 863 deep vein thrombosis patients. No significant differences were detected with inferior vena cava filters placement with regard to the incidence of recurrent pulmonary embolism or fatal pulmonary embolism. There were also no significant differences in the incidence of recurrent deep vein thrombosis or mortality with inferior vena cava filters placement at three months. Conclusions Inferior vena cava filter in addition to anticoagulation was not associated with a reduction in the incidence of recurrent pulmonary embolism as compared with anticoagulation alone in patients with deep vein thrombosis in the short term.
Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk
Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauter, Alexander; Triller, Juergen; Schmidt, Felix
Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less
A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions
Montgomery, Jennifer P.; Kaufman, John A.
2016-01-01
Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration. PMID:27247475
A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions.
Montgomery, Jennifer P; Kaufman, John A
2016-06-01
Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration.
Osteodiskitis of Lumbar Spine Due to Migrated Fractured Inferior Vena Cava Filter.
Aoun, Salah G; Bedros, Nicole; El Ahmadieh, Tarek Y; Kreck, Jake; Mehta, Nikhil; Al Tamimi, Mazin
2018-05-01
Venous thromboembolism can be a significant cause of morbidity in the trauma population. Medical and surgical specialties have been pushing the indication for prophylactic filter placement. A 36-year-old man presented with axial lower back pain with a radicular right L2 component after lifting a heavy object. He had a history of penetrating brain trauma 3 years prior, with placement of a prophylactic inferior vena cava filter. His radiograph, computed tomography, and magnetic resonance imaging of the lumbar spine showed fracture of his filter, with migration of the fractured fragment through the inferior vena cava and into the L2-L3 disk space, and surrounding bony lysis and severe osteodiskitis. He was treated medically with intravenous and then oral antibiotics and improved clinically and radiographically. Conservative use of filter devices and early retrieval once their indication expires are paramount to avoid unnecessary complications. Copyright © 2018 Elsevier Inc. All rights reserved.
Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef
2017-10-01
The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P < 0.001). Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.
Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.
Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C
2018-04-01
To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent
2013-11-01
A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.
Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R
2017-01-01
Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.
Makary, Mina S; Kapke, Jordan; Yildiz, Vedat; Pan, Xueliang; Dowell, Joshua D
2018-02-01
To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P < .01). Fluoroscopy time was similar for IR and OR filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Retrievable Inferior Vena Cava Filters for Venous Thromboembolism
Win, Lei Lei
2013-01-01
Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-01-01
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665
Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng
2018-04-11
A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.
Neill, Matthew; Charles, Hearns W; Pflager, Daniel; Deipolyi, Amy R
2017-01-01
We sought to delineate factors of inferior vena cava filter placement associated with increased radiation and cost and difficult subsequent retrieval. In total, 299 procedures from August 2013 to December 2014, 252 in a fluoroscopy suite (FS) and 47 in the operating room (OR), were reviewed for radiation exposure, fluoroscopy time, filter type, and angulation. The number of retrieval devices and fluoroscopy time needed for retrieval were assessed. Multiple linear regression assessed the impact of filter type, procedure location, and patient and procedural variables on radiation dose, fluoroscopy time, and filter angulation. Logistic regression assessed the impact of filter angulation, type, and filtration duration on retrieval difficulty. Access site and filter type had no impact on radiation exposure. However, placement in the OR, compared to the FS, entailed more radiation (156.3 vs 71.4 mGy; P = 0.001), fluoroscopy time (6.1 vs 2.8 min; P < 0.001), and filter angulation (4.8° vs 2.6°; P < 0.001). Angulation was primarily dependent on filter type ( P = 0.02), with VenaTech and Denali filters associated with decreased angulation (2.2°, 2.4°) and Option filters associated with greater angulation (4.2°). Filter angulation, but not filter type or filtration duration, predicted cases requiring >1 retrieval device ( P < 0.001) and >30 min fluoroscopy time ( P = 0.02). Cost savings for placement in the FS vs OR were estimated at $444.50 per case. In conclusion, increased radiation and cost were associated with placement in the OR. Filter angulation independently predicted difficult filter retrieval; angulation was determined by filter type. Performing filter placement in the FS using specific filters may reduce radiation and cost while enabling future retrieval.
Stavropoulos, S William; Chen, James X; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Abdel Aal, Ahmed Kamel; Lansky, Alexandra; Muhs, Bart E
2016-10-01
To report the final 2-year data on the efficacy and safety of a nitinol retrievable inferior vena cava (IVC) filter for protection against pulmonary embolism (PE). This was a prospective multicenter trial of 200 patients with temporary indications for caval filtration who underwent implantation of the Denali IVC filter. After filter placement, all patients were followed for 2 years after placement or 30 days after filter retrieval. The primary endpoints were technical success of filter implantation in the intended location and clinical success of filter placement and retrieval. Secondary endpoints were incidence of clinically symptomatic recurrent PE, new or propagating deep vein thrombosis (DVT), and filter-related complications including migration, fracture, penetration, and tilt. Filter placement was technically successful in 199 patients (99.5%). Filters were clinically successful in 190 patients (95%). The rate of PE was 3% (n = 6), with 5 patients having a small subsegmental PE and 1 having a lobar PE. New or worsening DVT was noted in 26 patients (13%). Filter retrieval was attempted 125 times in 124 patients and was technically successful in 121 patients (97.6%). The mean filter dwell time at retrieval was 200.8 days (range, 5-736 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of filter retrieval or during follow-up. The Denali IVC filter exhibited high success rates for filter placement and retrieval while maintaining a low complication rate in this clinical trial. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Kuo, William T; Robertson, Scott W
2015-01-01
A 46-year-old woman underwent inferior vena cava filter placement before bariatric surgery and returned within 6 months for routine removal. She complained of a 1-week history of severe chest pain, and during retrieval, two fractured filter components were identified including one arm in the right ventricle. The filter body and one fragment were successfully retrieved, but the fragment in the right ventricle was refractory to percutaneous retrieval. During open-heart surgery, the fragment was found traversing through the ventricular wall resulting in cardiac tamponade. Electron microscopic fragment analysis revealed high-cycle metal fatigue indicating the filter design failed to withstand this patient's natural inferior vena cava biomechanical motions. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Everhart, Damian; Vaccaro, Jamieson; Worley, Karen; Rogstad, Teresa L; Seleznick, Mitchel
2017-08-01
The role of inferior vena cava filter (IVC) filters for prevention of pulmonary embolism (PE) is controversial. This study evaluated outcomes of IVC filter placement in a managed care population. This retrospective cohort study evaluated data for individuals with Humana healthcare coverage 2013-2014. The study population included 435 recipients of prophylactic IVC filters, 4376 recipients of therapeutic filters, and two control groups, each matched to filter recipients. Patients were followed for up to 2 years. Post-index anticoagulant use, mortality, filter removal, device-related complications, and all-cause utilization. Adjusted regression analyses showed a positive association between filter placement and anticoagulant use at 3 months: odds ratio (ORs) 3.403 (95% CI 1.912-6.059), prophylactic; OR, 1.356 (95% CI 1.164-1.58), therapeutic. Filters were removed in 15.67% of prophylactic and 5.69% of therapeutic filter cases. Complication rates were higher with prophylactic procedures than with therapeutic procedures and typically exceeded 2% in the prophylactic group. Each form of filter placement was associated with increases in all-cause hospitalization (regression coefficient 0.295 [95% CI 0.093-0.498], prophylactic; 0.673 [95% CI 0.547-0.798], therapeutic) and readmissions (OR 2.444 [95% CI 1.298-4.602], prophylactic; 2.074 [95% CI 1.644-2.616], therapeutic). IVC filter placement in this managed care population was associated with increased use of anticoagulants and greater healthcare utilization compared to controls, low rates of retrieval, and notable rates of device-related complications, with effects especially pronounced in assessments of prophylactic filters. These findings underscore the need for appropriate use of IVC filters.
The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ray, Charles E.; Prochazka, Allan
Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less
British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross; Chalmers, Nicholas
Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertionmore » and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.« less
Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele
2018-03-01
The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.
Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael
2018-06-04
Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Perforation of the heart by an inferior vena cava filter.
Bolton, J W; Aldea, G S
1994-04-01
The use of vena caval filters to prevent pulmonary emboli has become routine. Although the complications have been well described, we present the first reported case of perforation of the heart and subsequent cardiac tamponade several months following placement of a Gintureo-Roehm "bird's nest" filter.
Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana
Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less
Charalel, Resmi A; Durack, Jeremy C; Mao, Jialin; Ross, Joseph S; Meltzer, Andrew J; Sedrakyan, Art
2018-03-01
Public awareness of inferior vena cava (IVC) filter-related controversies has been elevated by the Food and Drug Administration (FDA) safety communication in 2010. To examine population level trends in IVC filter utilization, complications, retrieval rates, and subsequent pulmonary embolism (PE) risk. A retrospective cohort study. Patients receiving IVC filters during 2005-2014 in New York State. IVC filter-specific complications, new PE occurrences and IVC filter retrievals were evaluated as time-to-event data using Kaplan-Meier analysis. Estimated cumulative risks were obtained at various timepoints during follow-up. There were 91,873 patients receiving IVC filters between 2005 and 2014 in New York State included in the study. The average patient age was 67 years and 46.6% were male. Age-adjusted rates of IVC filter placement increased from 48 cases/100,000 in 2005 to 52 cases/100,000 in 2009, and decreased afterwards to 36 cases/100,000 in 2014. The estimated risks of having an IVC filter-related complication and filter retrieval within 1 year was 1.5% [95% confidence interval (CI), 1.4%-1.6%] and 3.5% (95% CI, 3.4%-3.6%). One-year retrieval rate was higher post-2010 when compared with pre-2010 years (hazard ratio, 2.70; 95% CI, 2.50-2.91). Among the 58,176 patients who did not have PE events before or at the time of IVC filter placement, the estimated risk of developing subsequent PE at 1 year was 2.0% (95% CI, 1.9%-2.1%). Our findings suggest that FDA communications may be effective in modifying statewide clinical practices. Given the 2% observed PE rate following prophylactic IVC filter placement, large scale pragmatic studies are needed to determine contemporary safety and effectiveness of IVC filters.
Yamashita, Yugo; Unoki, Takashi; Takagi, Daisuke; Hamatani, Yasuhiro; Ishii, Mitsuru; Iguchi, Moritake; Ogawa, Hisashi; Masunaga, Nobutoyo; Wada, Hiromichi; Hasegawa, Koji; Abe, Mitsuru; Akao, Masaharu
2016-07-01
A recent multicenter registry study of venous thromboembolism (VTE) patients in Japan demonstrated a high prevalence of inferior vena cava (IVC) filter placement. However, data regarding indications, applications, and outcomes of IVC filters in Japanese patients are quite limited. This study was an observational, single-center, retrospective cohort study of all consecutive patients with acute VTE treated between March 2006 and February 2014. Data extracted included patient demographics, indications, applications, and complications of IVC filters, as well as VTE recurrence and death. A total of 257 consecutive patients were analyzed. Seventy-eight patients (30 %) received IVC filters. The proportions of IVC filter placement were 26 % for deep-vein thrombosis (DVT) alone, 10 % for pulmonary embolism (PE) alone, and 46 % for both DVT and PE. There was no significant difference in patient demographics between the IVC filter group and no-IVC filter group. Stated indications for filter placement were 24 cases (30 %) of DVT in intrapelvic veins, 16 cases (20 %) of DVT in proximal veins, and 11 cases (14 %) of contraindication to anticoagulant therapy. In the IVC filter group, cases of class I indication (guidelines: JCS 75:1258-1281, 2009) numbered only 6 (8 %). Many of the retrievable IVC filters were not removed and placed permanently and the retrieval rate was 42 %. We found complications of IVC filters in 8 cases (10 %). IVC filter placement was significantly associated with a better survival rate and a higher incidence of DVT recurrence during a mean observation period of 541 days. Our research suggests the frequent use of IVC filters for VTE treatment, combined with a low retrieval rate. Most of the stated indications of IVC filter placement for VTE in Japanese patients were cases of DVT in intrapelvic veins or proximal veins, not cases of contraindication to anticoagulant therapy.
Duffett, L; Carrier, M
2017-01-01
Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.
Olorunsola, Olufoladare G; Kohi, Maureen P; Fidelman, Nicholas; Westphalen, Antonio C; Kolli, Pallav K; Taylor, Andrew G; Gordon, Roy L; LaBerge, Jeanne M; Kerlan, Robert K
2013-04-01
To compare the frequency of vena caval penetration by the struts of the Option and Günther Tulip cone filters on postplacement computed tomography (CT) imaging. All patients who had an Option or Günther Tulip inferior vena cava (IVC) filter placed between January 2010 and May 2012 were identified retrospectively from medical records. Of the 208 IVC filters placed, the positions of 58 devices (21 Option filters, 37 Günther Tulip filters [GTFs]) were documented on follow-up CT examinations obtained for reasons unrelated to filter placement. In cases when multiple CT studies were obtained after placement, each study was reviewed, for a total of 80 examinations. Images were assessed for evidence of caval wall penetration by filter components, noting the number of penetrating struts and any effect on pericaval tissues. Penetration of at least one strut was observed in 17% of all filters imaged by CT between 1 and 447 days following placement. Although there was no significant difference in the overall prevalence of penetration when comparing the Option filter and GTF (Option, 10%; GTF, 22%), only GTFs showed time-dependent penetration, with penetration becoming more likely after prolonged indwelling times. No patient had damage to pericaval tissues or documented symptoms attributed to penetration. Although the Günther Tulip and Option filters exhibit caval penetration at CT imaging, only the GTF exhibits progressive penetration over time. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.
Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jha, V. M., E-mail: vjha@mfa.gwu.ed; Lee-Llacer, J.; Williams, J.
Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not anmore » IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.« less
Doshi, Mehul Harshad; Narayanan, Govindarajan
2016-12-01
Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.
Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results.
Reis, Stephen P; Kovoor, Jerry; Sutphin, Patrick D; Toomay, Seth; Trimmer, Clayton; Pillai, Anil; Reddick, Mark; Kalva, Sanjeeva P
2016-08-01
The purpose of the study is to evaluate the clinical safety and effectiveness of the Denali (Bard, Tempe, Arizona) retrievable inferior vena cava (IVC) filter. In this retrospective study, authors reviewed the data of Denali IVC filters placed at their institution between 2013 and 2015. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. The frequency of post filter pulmonary embolism (PE) and filter-related complications was assessed. Denali filters were placed in 87 patients (47 males; mean age: 56 years). Twenty patients presented with PE, 45 with deep vein thrombosis (DVT), and 21 with both PE and DVT, 1 filter was placed prophylactically before surgery. Indications for filter placement included contraindications to anticoagulation (AC; n = 80), failure of AC (n = 4), and complications of AC (n = 3). No patients had PE on follow-up imaging after filter placement. Retrieval was attempted in 31 patients after a mean period of 125 days (range: 34-324 days). The filter was successfully removed in 31 (100%) patients. Follow-up imaging, available in 71 (82%) patients (range: 2-538 days), demonstrated penetration of 15 legs in 5 patients, caval thrombus in 3, 1 resulting in caval occlusion, <15° filter tilt in 5, and no leg fractures or crossed legs. The Denali filter is safe during deployment and readily retrievable. The overall safety following deployment is similar to those reported in the literature, and the incidence of filter fractures and migration appears to be less than the previous generation of Bard devices. © The Author(s) 2016.
OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onat, Levent, E-mail: levonat2@yahoo.com; Ganiyusufoglu, Ali Kursat; Mutlu, Ayhan
We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9).more » Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.« less
Stavropoulos, S William; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Aal, Ahmed Kamel Abdel; Lansky, Alexandra J; Settlage, Richard A; Muhs, Bart E
2014-10-01
To assess safety and effectiveness of a nitinol retrievable inferior vena cava (IVC) filter in patients who require caval interruption to protect against pulmonary embolism (PE). Two hundred patients with temporary indications for an IVC filter were enrolled in this prospective, multicenter clinical study. Patients undergoing filter implantation were to be followed for 2 years or for 30 days after filter retrieval. At the time of the present interim report, all 200 patients had been enrolled in the study, and 160 had undergone a retrieval attempt or been followed to 6 months with their filter in place. Primary study endpoints included technical and clinical success of filter placement and retrieval. Patients were also evaluated for recurrent PE, new or worsening deep vein thrombosis, and filter migration, fracture, penetration, and tilt. Clinical success of placement was achieved in 94.5% of patients (172 of 182), with a one-sided lower limit of the 95% confidence interval of 90.1%. Technical success rate of filter placement was 99.5%. Technical success rate of retrieval was 97.3%; 108 filters were retrieved in 111 attempts. In two cases, the filter apex could not be engaged with a snare, and one device was engaged but could not be removed. Filter retrievals occurred at a mean indwell time of 165 days (range, 5-632 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of retrieval or 6-month follow-up. In this interim report, the nitinol retrievable IVC filter provided protection against pulmonary embolism, and the device could be retrieved with a low rate of complications. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.
Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin
2016-12-01
Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
It all unraveled from there: case report of a central venous catheter guidewire unraveling.
Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc
2014-12-01
Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.
Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.
Hoffer, Eric K; Mueller, Rebecca J; Luciano, Marcus R; Lee, Nicole N; Michaels, Anne T; Gemery, John M
2013-08-01
To evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter. A retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59% were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86% of patients; 14% were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records. Mean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3%). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4%). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8%) at a mean of 731 days revealed a single (0.3%) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5%), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4%) at a mean 757 days. The Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.
Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.org; Mueller, Rebecca J.; Luciano, Marcus R.
PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinicalmore » follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.« less
Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geisbuesch, Philipp, E-mail: philippgeisbuesch@gmx.de; Benenati, James F.; Pena, Constantino S.
Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11-95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients hadmore » an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.« less
Complications of inferior vena cava filters
Grewal, Simer; Chamarthy, Murthy R.
2016-01-01
Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983
Inferior vena cava filter retrievals, standard and novel techniques.
Kuyumcu, Gokhan; Walker, T Gregory
2016-12-01
The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques.
Inferior vena cava filter retrievals, standard and novel techniques
Walker, T. Gregory
2016-01-01
The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques. PMID:28123984
Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data
Molvar, Christopher
2012-01-01
Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414
Case of a Misplaced IVC Filter: A Lesson to Learn
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharma, Sanjay, E-mail: drssharma@hotmail.com; Mukund, Amar, E-mail: dramarmukund@gmail.co; Agarwal, Sandeep, E-mail: sandeep_aiims@yahoo.co.i
2010-08-15
The inferior vena cava (IVC) filter insertion is a well established procedure to prevent significant pulmonary embolism in selected situations. It is generally considered straight forward without significant complications. We report an interesting case of a young postpartum woman in whom an IVC filter was misplaced in the right gonadal vein. This complication is only rarely reported. Presence of prominent right gonadal vein must always be kept in mind during trans-jugular placement of infra renal filter in the IVC in post partum women.
Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M
2016-12-01
To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
The role of interventional radiology in management of benign and malignant gynecologic diseases.
Yu, Hyeon; Stavas, Joseph M
2013-10-01
This article focuses on the role of interventional radiology in the therapeutic and diagnostic management of benign and malignant gynecologic conditions. The subspecialty of interventional radiology utilizes minimally invasive advanced image-guided percutaneous techniques in gynecology that include central venous catheter placement, fluid aspiration, drainage catheter placement, tissue biopsy, inferior vena cava filter placement, and pelvic arterial embolization. Central venous catheters, such as ports, peripherally inserted central catheters, and tunneled catheters, are placed for intermediate to long-term intravenous chemotherapy or total parental nutrition or antibiotics. Patients with refractory malignant ascites or pleural effusion from seeding of advanced gynecologic cancers may benefit by percutaneous aspiration of fluid collections or placement of drainage catheters. Postoperative fluid collections including abscess, seroma, or lymphocele are managed by percutaneous drainage catheter insertion. Pelvic, peritoneal, or retroperitoneal masses can be sampled by image-guided percutaneous biopsy or aspiration of fluid to determine a pathologic diagnosis. Certain patients are at risk for deep venous thrombosis with pulmonary embolism and may benefit from an inferior vena cava filter. Patients with uncontrolled postoperative or postpartum bleeding can be effectively managed with emergent transarterial pelvic embolization. Each of the aforementioned interventions with indications, expected benefits, and complications is described including a published literature.
Wadhwa, Vibhor; Trivedi, Premal S; Ali, Sumera; Ryu, Robert K; Pezeshkmehr, Amir
2018-02-01
Inferior vena cava (IVC) filter placement in children has been described in literature, but there is variability with regard to their indications. No nationally representative study has been done to compare practice patterns of filter placements at adult and children's hospitals. To perform a nationally representative comparison of IVC filter placement practices in children at adult and children's hospitals. The 2012 Kids' Inpatient Database was searched for IVC filter placements in children <18 years of age. Using the International Classification of Diseases, 9th Revision (ICD-9) code for filter insertion (38.7), IVC filter placements were identified. A small number of children with congenital cardiovascular anomalies codes were excluded to improve specificity of the code used to identify filter placement. Filter placements were further classified by patient demographics, hospital type (children's and adult), United States geographic region, urban/rural location, and teaching status. Statistical significance of differences between children's or adult hospitals was determined using the Wilcoxon rank sum test. A total of 618 IVC filter placements were identified in children <18 years (367 males, 251 females, age range: 5-18 years) during 2012. The majority of placements occurred in adult hospitals (573/618, 92.7%). Significantly more filters were placed in the setting of venous thromboembolism in children's hospitals (40/44, 90%) compared to adult hospitals (246/573, 43%) (P<0.001). Prophylactic filters comprised 327/573 (57%) at adult hospitals, with trauma being the most common indication (301/327, 92%). The mean length of stay for patients receiving filters was 24.5 days in children's hospitals and 18.4 days in adult hospitals. The majority of IVC filters in children are placed in adult hospital settings. Children's hospitals are more likely to place therapeutic filters for venous thromboembolism, compared to adult hospitals where the prophylactic setting of trauma predominates.
Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ha, Thuong G. Van; Chien, Andy S.; Funaki, Brian S.
The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonarymore » embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.« less
SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitcham, T; Bouchard, R; Melancon, A
Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic amore » human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.« less
Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K
2015-04-01
To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.
Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F
2018-05-03
To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.
Huang, Steven Y; Eggers, Mitchell; McArthur, Mark J; Dixon, Katherine A; McWatters, Amanda; Dria, Stephen; Hill, Lori R; Melancon, Marites P; Steele, Joseph R; Wallace, Michael J
2017-12-01
Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3). Autologous thrombus was administered from below the filter in seven swine from 0 to 35 days after filter placement. Fluoroscopy and computed tomography follow-up was performed after filter deployment from weeks 1-6 (weekly), weeks 7-20 (biweekly), and weeks 21-32 (monthly). The infrarenal IVC, lungs, heart, liver, kidneys, and spleen were harvested at necropsy. Continuous variables were evaluated with a Student t test. Results There was no evidence of IVC thrombosis, device migration, caval penetration, or pulmonary embolism. Gross pathologic analysis showed gradual device resorption until 32 weeks after deployment. Histologic assessment demonstrated neointimal hyperplasia around the IVC filter within 2 weeks after IVC filter deployment with residual microscopic fragments of polydioxanone suture within the caval wall at 32 weeks. Each iatrogenic-administered thrombus was successfully captured by the filter until resorbed (range, 1-4 weeks). Conclusion An absorbable IVC filter can be safely deployed in swine and resorbs gradually over the 32-week testing period. The device is effective for the prevention of pulmonary embolism for at least 5 weeks after placement in swine. © RSNA, 2017.
Glocker, Roan J; Awonuga, Oluwafunmi; Novak, Zdenek; Pearce, Benjamin J; Patterson, Mark; Matthews, Thomas C; Jordan, William D; Passman, Marc A
2014-10-01
Bedside inferior vena cava filter (IVCF) placement by intravascular ultrasound (IVUS) guidance has previously been shown to be a safe and effective technique, especially for critically ill patients, with initial experience of a prospectively implemented algorithm. The purpose of this study was to evaluate the effectiveness of IVUS-guided filter placement in critically ill patients with experience now extending out 5 years from implementation. All patients undergoing bedside IVUS-guided IVCF placement from 2008 to 2012 were identified. Records were reviewed on the basis of IVCF reporting standards. Outcomes data including technical success, complications, and mortality were analyzed at 30 days. During the 5-year period, 398 patients underwent attempted bedside IVCF placement by IVUS. Technical feasibility was possible in 396 cases (99.5%); two bedside procedures were aborted because of inadequate IVUS visualization. Overall technical success was achieved in 393 of 396 (99.2%), with malpositioned IVCF in three cases. An optional IVCF was used in 372 (93.9%) and a permanent IVCF in 24 (6.1%). Single-puncture technique was performed in 388 (97.4%); additional dual access was required in 10 (2.6%). Periprocedural complications were rare (3.0%) and included malpositioning that required retrieval and repositioning or an additional IVCF (3), filter tilt ≥20 degrees (4), arteriovenous fistulas (2), insertion site thrombosis (2), and hematoma (1). Comparison of the first 100 procedures performed within the sample population with the last 100 procedures revealed an overall success rate of 96% in the first 100 compared with 100% in the last 100 (P = .043). There were no deaths related to pulmonary embolism or IVCF-related problems. On the basis of 5 years of experience with bedside IVCF placement in critically ill patients, the IVUS-guided IVCF technique continues to be a safe and effective option in this high-risk population, with a time-dependent improvement in outcome measures. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R
2015-10-01
Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.
Glocker, Roan J; TerBush, Matthew J; Hill, Elaine L; Guido, Joseph J; Doyle, Adam; Ellis, Jennifer L; Raman, Kathleen; Morrow, Gary R; Stoner, Michael C
2017-01-01
On January 1, 2012, reimbursement for inferior vena cava filters (IVCFs) became bundled by the Centers for Medicare and Medicaid Services. This resulted in ICVF placement (CPT code 37191) now yielding 4.71 relative value units (RVUs), a decrease from 15.6 RVUs for placement and associated procedures (CPT codes 37620, 36010, 75825-26, 75940-26). Our hypothesis was that IVCF utilization would decrease in response to this change as other procedures had done once they had become bundled. Including data from 2010 to 2011 (before bundling) and 2012 to 2014 (after bundling), we utilized 5% inpatient, outpatient, and carrier files of Medicare limited data sets and analyzed IVCF utilization before and after bundling across specialty types, controlling for total diagnosis of deep vein thrombosis (DVT) and pulmonary embolism (PE) (ICD-9 codes 453.xx and 415.xx, respectively) and placement location. In 2010 and 2011, the rates/10,000 DVT/PE diagnoses were 918 and 1,052, respectively (average 985). In 2012, 2013, and 2014, rates were 987, 877, and 605, respectively (average 823). Comparing each year individually, there is a significant difference (P < 0.0001) with 2012, 2013, and 2014 having lower rates of ICVF utilization. Comparing averages in the 2010-2011 and 2012-2014 groups, there is also a significant decrease in utilization after bundling (P < 0.0001). Following the bundling of reimbursement for IVCF placement, procedural utilization decreased significantly. More data from subsequent years will be needed to show if this decrease utilization continues to persist. Copyright © 2016 Elsevier Inc. All rights reserved.
Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach
Inagaki, Elica; Farber, Alik; Eslami, Mohammad H.; Siracuse, Jeffrey J.; Rybin, Denis V.; Sarosiek, Shayna; Sloan, J. Mark; Kalish, Jeffrey
2017-01-01
Objective The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. Methods All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. Results In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). Conclusions The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. PMID:27318045
Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok
2016-05-01
To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.
Coombs, Catherine; Kuk, Deborah; Devlin, Sean; Siegelbaum, Robert H; Durack, Jeremy C; Parameswaran, Rekha; Mantha, Simon; Deng, Kathy; Soff, Gerald
2017-11-01
Venous thromboembolism (VTE) is a common complication in cancer patients and anticoagulation (AC) remains the standard of care for treatment. Inferior vena cava (IVC) filters may also used to reduce the risk of pulmonary embolism, either alone or in addition to AC. Although widely used, data are limited on the safety and efficacy of IVC filters in cancer patients. We performed a retrospective review of outcomes after IVC filter insertion in a database of 1270 consecutive patients with cancer-associated pulmonary embolism (PE) at our institution between 2008 and 2009. Outcomes measured included rate of all recurrent VTE, recurrent PE, and overall survival within 12 months. 317 (25%) of the 1270 patients with PE had IVC filters placed within 30 days of the index PE event or prior to the index PE in the setting of prior DVT. Patients with IVC filters had markedly lower overall survival (7.3 months) than the non-IVC filter patients (13.2 months). Filter patients also had a lower rate of AC use at time of initial PE. There was a trend towards higher recurrent VTE in patients with IVC filters (11.9%) compared to non-filter patients (7.7%), but this was not significant (p = 0.086). The risk of recurrent PE was similar between the IVC filter cohort (3.5%) and non-filter group (3.5%, p = 0.99). Cancer patients receiving IVC filters had a similar risk of recurrent PE, but a trend towards more overall recurrent VTE. The filter patients had poorer overall survival, which may reflect a poorer cancer prognosis, and had greater contraindication to AC; therefore these patients likely had a higher inherent risk for recurrent VTE. A prospective study would be helpful for further clarification on the partial reduction in the recurrent PE risk by IVC filter placement in cancer patients.
Complications and Retrieval Data of Vena Cava Filters Based on Specific Infrarenal Location.
Tullius, Thomas G; Bos, Aaron S; Patel, Mikin V; Funaki, Brian; Van Ha, Thuong G
2018-02-01
Although recommended placement of IVC filters is with their tips positioned at the level of the renal vein inflow, in practice, adherence is limited due to clinical situation or IVC anatomy. We seek to evaluate the indwelling and retrieval complications of IVC filters based on their specific position within the infrarenal IVC. Retrospective, single institution study of 333 consecutive infrarenal vena cava filters placed by interventional radiologists in patients with an average age of 62.2 ± 15.7 years was performed between 2013 and 2015. Primary indication was venous thromboembolic disease (n = 320, 96.1%). Filters were classified based on location of the apex below the lowest renal vein inflow on the procedural venogram: less than 1 cm (n = 180, 54.1%), 1-2 cm (n = 96, 28.8%), and greater than 2 cm (n = 57, 17.1%). Denali (n = 171, 51.4%) and Celect (n = 162, 48.6%) filters were evaluated. CT follow-up, indwelling complications, and retrieval data were obtained. Follow-up CT imaging performed for symptomatic indications occurred for 38.3% of filters placed < 1 cm below the lowest renal vein, 27.1% of filters placed 1-2 cm, and 36.8% placed > 2 cm (p = .16). There was no difference in caval strut penetration, penetration of adjacent viscera, time to penetration, filter migration, or tilt (p = .15, .27, .41, .57, .93). No filter fractures occurred. There was no difference in the incidence of breakthrough PE or complex filter retrieval (p = .83, .59). Only one retrieval failure occurred. This study suggests filter apex location within the infrarenal IVC, including placement > 2 cm below the level of the renal vein inflow, is not associated with differences in indwelling or retrieval complications. Level 3 non-randomized controlled follow-up study.
Du Plessis, Lodewyk E; Mol, Ben W; Svigos, John M
2016-09-01
Pregnant women with venous thromboembolism are traditionally managed with anticoagulation, but inferior vena cava filters are an alternative. We balanced risks and benefits of an inferior vena cava filter in a decision analysis. We constructed a decision model to compare in pregnant women with VTE the outcome of (1) inferior vena cava filter and anticoagulant treatment versus (2) anticoagulant treatment only. Assuming a 63% risk reduction from an inferior vena cava filter (baseline mortality rate of venous thromboembolism of 0.5%), 318 women would need to be treated with inferior vena cava filters to prevent one venous thromboembolism related maternal death. Sensitivity analyses indicated that at a mortality rate of 0.5% the risk reduction from inferior vena cava filters needed to be 80%, while at a mortality rate of 2% a risk reduction of 20% would justify inferior vena cava filters. In view of their potential morbidity, inferior vena cava filters should be restricted to pregnant woman at strongly increased risk of recurrent venous thromboembolism.
Factors affecting Cook Gunther Tulip and Cook Celect inferior vena cava filter retrieval success.
Glocker, Roan J; Novak, Zdenek; Matthews, Thomas C; Patterson, Mark A; Jordan, William D; Pearce, Benjamin J; Passman, Marc A
2014-01-01
Success rates vary for the retrieval of inferior vena cava filters (IVCFs). The optimal retrieval time and factors influencing retrieval success remain unproven. This study aims to determine optimal time and evaluate factors related to successful IVCF retrieval. An institutional prospectively maintained database was reviewed for all IVCF retrieval attempts from 2006 to 2012. Patient demographics, comorbidities, indications for procedure, placement technique, IVCF type, presence of angulation, and time to retrieval were evaluated with respect to success or failure of retrieval. Statistical analyses (t-test, χ(2), correlations, and Kaplan-Meier plots) were performed comparing successful and unsuccessful retrievals. Of 121 attempted IVCF retrievals, 92 (76%) were successful and 29 (24%) were unsuccessful. There were no significant differences between the successful and unsuccessful attempts in terms of patient demographics, comorbidities, indications for procedure, placement technique, or IVCF type, which included 93 Celect (77%) and 28 Gunther Tulip (23%). Time since IVCF placement was significantly different (P = .025) between the successful and unsuccessful retrieval groups (medians were 105 [7-368] and 162 [43-379] days, respectively). Time since IVCF placement greater than 117 days correlated significantly with unsuccessful IVCF retrieval (R = 0.218; P = .017; odds ratio, 2.88; P = .02). Angulation greater than 20 degrees on anteroposterior radiograph was noted in seven of 29 (24%) unsuccessful retrievals compared with seven of 92 (8%) successful retrievals and was significant (P = .012). Cook Gunther Tulip and Celect IVCF retrieval is most likely to be successful within 3 to 4 months of placement. Unsuccessful retrieval attempts are more likely to occur when IVCF position is angulated. Copyright © 2014 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Rajasekhar, Anita; Lottenberg, Lawrence; Lottenberg, Richard; Feezor, Robert J; Armen, Scott B; Liu, Huazhi; Efron, Philip A; Crowther, Mark; Ang, Darwin
2011-08-01
Placement of prophylactic inferior vena cava filters (pIVCFs) for the prevention of pulmonary embolism (PE) in high-risk trauma patients (HRTPs) are widely practiced despite the lack of Level I data supporting this use. We report the 2-year interim analysis of the Filters in Trauma pilot study. This is a single institution, prospective randomized controlled pilot feasibility study in a Level I trauma center. HRTPs were identified for pIVCF placement by the Eastern Association for the Surgery of Trauma guidelines. From November 2008 to November 2010, HRTPs were enrolled and randomized to either pIVCF or no pIVCF. All patients received pharmacologic prophylaxis when safe. Primary outcomes included feasibility objectives and secondary outcomes were incidence of PE, deep vein thrombosis (DVT), and death. Thirty-four of 38 enrolled patients were eligible for analysis. The baseline sociodemographic characteristics were balanced between the both groups. Results of the feasibility objectives included: time from admission to enrollment (mean, 47.4 hours ± 22.0 hours), time from enrollment to randomization (mean, 4.8 hours ± 9.1 hours), time from randomization to IVCF placement (mean, 16.9 hours ± 9.2 hours), adherence to weekly compression ultrasound within first month (IVCF group = 44.4%; non-IVCF group = 62.5%), and 1-month clinical follow-up (IVCF group = 83.3%; non-IVCF group = 100%). At 6-month follow-up, one PE in the nonfilter group and one DVT in the filter group had occurred. One non-PE-related death occurred in the filter group. Barriers to enrollment included inability to obtain informed consent due to patient refusal or no next of kin identified and delayed notification of eligibility status. Our pilot study demonstrates for the first time that a randomized controlled trial evaluating the efficacy of pIVCFs in trauma patients is feasible. This pilot data will be used to inform the design of a multicenter randomized controlled trial to determine the incidence of PE and DVT in HRTPs receiving pIVCFs versus no pIVCF.
Jiang, Jianguang; Tu, Jianfei; Jia, Zhongzhi; Chen, Jiezhong; Cao, Haitao; Meng, Qingli; Fuller, Tyler A; Tian, Feng
2017-01-01
The aim of the study was to retrospectively evaluate the incidence and outcomes of inferior vena cava (IVC) filter thrombus during catheter-directed thrombolysis (CDT) for acute proximal deep venous thrombosis (DVT). From October 2006 to June 2015, patients diagnosed with acute proximal DVT and received CDT after a retrievable IVC filter was placed were included. The incidence, treatment, and outcomes of IVC filter thrombus during CDT were recorded and analyzed. A total of 189 patients (91 women, 98 men; mean age, 57.6 ± 9.8 years; range, 24-85 years) were included in this study. Among the 189 cases, the DVTs involved popliteal iliofemoral veins in 54 patients, iliofemoral veins in 113 patients, and iliac veins in 22 patients, of which 18 patients had thrombus extended into the IVC. Of the 189 patients, a total of 8 (4.2%, 8 of 189) patients were identified with IVC filter thrombus during CDT. The IVC filter thrombus was detected on a median of 2 days (range, 2-4 days) of CDT therapy, including small-size (n = 6) and large-size (n = 2) filter thrombus. Of the 8 patients, CDTs were performed with a mean 7.6 ± 1.1 days (range, 6-11 days) after the presence of symptoms for the treatment of proximal DVT, and all the IVC filter thrombi were lysed during CDT for the proximal DVT. All the IVC filters were removed successfully with a mean of 12.8 ± 0.93 days from placement. There were no procedure- or thrombolysis-related major complications, and no symptomatic pulmonary embolism breakthrough was seen in any of the patients after the filter placement. IVC filter thrombus during CDT for the acute proximal DVT is uncommon, and all of them did not need any additional treatment. Copyright © 2016 Elsevier Inc. All rights reserved.
Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A
2010-05-01
Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively implemented algorithm, thereby limiting the need for transport in this high-risk population. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Falatko, John M; Dalal, Bhavinkumar; Qu, Lihua
2017-12-01
Anticoagulation is the primary treatment for pulmonary embolism (PE). Inferior vena cava (IVC) filters are an adjunctive intervention to prevent recurrent pulmonary embolism. Long-term outcomes in elderly patients with contraindications to anticoagulation after IVC filter placement for prevention of recurrent pulmonary embolism have yet to be assessed. Patients ≥60years of age, that had an IVC filter placed between 1 January, 2008 and 2 February, 2013, with a primary diagnosis of pulmonary embolism, were included. Patients that died during index hospitalisation, were discharged to hospice, or had active malignancy were excluded. The primary endpoint was overall survival. Patients were divided depending on whether they were treated with an approved anticoagulant for VTE or had no anticoagulant. Of the 152 patients identified, 55 were not anti-coagulated after IVC filter placement. The incidence of death was 0.4 per 1000 filter days and 0.7 per 1000 filter days in the anti-coagulated and untreated groups respectively (p-value=0.06). After statistical correction for co-morbid conditions, the effect of anticoagulation was not significant (HR 0.82 CI 0.49-1.37, p-value 0.46). Age was a significant confounder that was associated with death. Increased BMI was protective. Indications for IVC filter placement were numerous, but similar between the two groups. Treatment with an approved anticoagulant is recommended after IVC filter placement for prevention of recurrent PE, however its effect may be attenuated by advanced age. In elderly patients that have undergone IVC filter placement for prevention of recurrent PE, survival may be more dependent on age and co-morbid conditions than exposure to anticoagulation. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach.
Inagaki, Elica; Farber, Alik; Eslami, Mohammad H; Siracuse, Jeffrey J; Rybin, Denis V; Sarosiek, Shayna; Sloan, J Mark; Kalish, Jeffrey
2016-07-01
The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Inferior vena cava filters in trauma patients: efficacy, morbidity, and retrievability.
Smoot, Rory L; Koch, Cody A; Heller, Stephanie F; Sabater, Enrique A; Cullinane, Daniel C; Bannon, Michael P; Thomsen, Kristine M; Harmsen, William S; Baerga-Varela, Yvonne; Schiller, Henry J
2010-04-01
Thromboembolic events are potentially devastating sources of morbidity in trauma patients. With increasing experience and the introduction of retrievable devices, there has been a renewed interest in inferior vena cava (IVC) filters in trauma patients. The records for consecutive trauma patients undergoing IVC filter placement during the years 2001 to 2005 were reviewed, and clinical, demographic, and procedural data were evaluated for associations with thromboembolic events and device complications. During the study years, 226 trauma patients had IVC filters inserted, and 140 of these patients (62%) had retrievable IVC filters placed. Six patients (3%) had a pulmonary embolism with the filter in place, and two patients (1%) had a pulmonary embolism after filter removal. The most common complication was thrombosis in 27 patients (12%), with clinically significant thrombus occurring in 15 patients (7%). There was no association between the type of filter (permanent or retrievable) or the brand of retrievable filter and thrombosis. Specific risk factors for thrombosis could not be identified. Retrievable filters were successfully removed in 61% of patients with retrievable filters. Technical success rate was 97% in those patients who underwent attempted removal. Removal was completed at a median of 21 days (range, 2-292 days). Retrievable IVC filters in trauma patients are safe, but complications do occur with thrombosis being the most common. Retrieval has a high technical success rate when attempted. However, a significant number of trauma patients are lost to follow-up and this may impact the utilization of retrievable filters in this patient population.
Complications of inferior vena cava filters.
Sella, David M; Oldenburg, W Andrew
2013-03-01
With the introduction of retrievable inferior vena cava filters, the number being placed for protection from pulmonary embolism is steadily increasing. Despite this increased usage, the true incidence of complications associated with inferior vena cava filters is unknown. This article reviews the known complications associated with these filters and suggests recommendations and techniques for inferior vena cava filter removal. Copyright © 2013. Published by Elsevier Inc.
Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William
2018-06-01
The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.
Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli
2016-02-01
Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.
Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping
2014-01-01
Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Litwin, Robert J; Huang, Steven Y; Sabir, Sharjeel H; Hoang, Quoc B; Ahrar, Kamran; Ahrar, Judy; Tam, Alda L; Mahvash, Armeen; Ensor, Joe E; Kroll, Michael; Gupta, Sanjay
2017-09-01
Our primary purpose was to assess the impact of an inferior vena cava filter retrieval algorithm in a cancer population. Because cancer patients are at persistently elevated risk for development of venous thromboembolism (VTE), our secondary purpose was to assess the incidence of recurrent VTE in patients who underwent filter retrieval. Patients with malignant disease who had retrievable filters placed at a tertiary care cancer hospital from August 2010 to July 2014 were retrospectively studied. A filter retrieval algorithm was established in August 2012. Patients and referring physicians were contacted in the postintervention period when review of the medical record indicated that filter retrieval was clinically appropriate. Patients were classified into preintervention (August 2010-July 2012) and postintervention (August 2012-July 2014) study cohorts. Retrieval rates and clinical pathologic records were reviewed. Filter retrieval was attempted in 34 (17.4%) of 195 patients in the preintervention cohort and 66 (32.8%) of 201 patients in the postintervention cohort (P < .01). The median time to filter retrieval in the preintervention and postintervention cohorts was 60 days (range, 20-428 days) and 107 days (range, 9-600 days), respectively (P = .16). In the preintervention cohort, 49 of 195 (25.1%) patients were lost to follow-up compared with 24 of 201 (11.9%) patients in the postintervention cohort (P < .01). Survival was calculated from the date of filter placement to death, when available. The overall survival for patients whose filters were retrieved was longer compared with the overall survival for patients whose filters were not retrieved (P < .0001). Of the 80 patients who underwent successful filter retrieval, two patients (2.5%) suffered from recurrent VTE (n = 1 nonfatal pulmonary embolism; n = 1 deep venous thrombosis). Both patients were treated with anticoagulation without filter replacement. Inferior vena cava filter retrieval rates can be significantly increased in patients with malignant disease with a low rate (2.5%) of recurrent VTE after filter retrieval. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Mechanisms of Günther Tulip filter tilting during transfemoral placement.
Matsui, Y; Horikawa, M; Ohta, K; Jahangiri Noudeh, Y; Kaufman, J A; Farsad, K
The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Huang, Steven Y; Odisio, Bruno C; Sabir, Sharjeel H; Ensor, Joe E; Niekamp, Andrew S; Huynh, Tam T; Kroll, Michael; Gupta, Sanjay
2017-07-01
Our purpose was to develop a predictive model for short-term survival (i.e. <6 months) following inferior vena cava filter placement in patients with venous thromboembolism (VTE) and solid malignancy. Clinical and laboratory parameters were retrospectively reviewed for patients with solid malignancy who received a filter between January 2009 and December 2011 at a tertiary care cancer center. Multivariate Cox proportional hazards modeling was used to assess variables associated with 6 month survival following filter placement in patients with VTE and solid malignancy. Significant variables were used to generate a predictive model. 397 patients with solid malignancy received a filter during the study period. Three variables were associated with 6 month survival: (1) serum albumin [hazard ratio (HR) 0.496, P < 0.0001], (2) recent or planned surgery (<30 days) (HR 0.409, P < 0.0001), (3) TNM staging (stage 1 or 2 vs. stage 4, HR 0.177, P = 0.0001; stage 3 vs. stage 4, HR 0.367, P = 0.0002). These variables were used to develop a predictive model to estimate 6 month survival with an area under the receiver operating characteristic curve of 0.815, sensitivity of 0.782, and specificity of 0.715. Six month survival in patients with VTE and solid malignancy requiring filter placement can be predicted from three patient variables. Our predictive model could be used to help physicians decide whether a permanent or retrievable filter may be more appropriate as well as to assess the risks and benefits for filter retrieval within the context of survival longevity in patients with cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, Richard A.; Teitelbaum, George P.; Stanley, Philip
Purpose: To report our experience with inferior vena cava (IVC) filters in pediatric patients. Methods: Over a 19-month period, eight low-profile percutaneously introducible IVC filters were placed in four male and four female patients aged 6-16 years (mean 11 years). Indications were contraindication to heparin in six patients, anticoagulation failure in one, and idiopathic infrarenal IVC thrombosis in one. Six of the eight devices placed were titanium Greenfield filters. One LGM and one Bird's Nest filter were also placed. Two of the filters were introduced via the right internal jugular vein by cutdown, and the remainder were placed percutaneously viamore » the right internal jugular vein or the right common femoral vein. Patients received follow-up abdominal radiographs from 2 to 13 months after IVC filter placement. Results: All filters were inserted successfully without complication. Three of the patients died during the follow-up period: two due to underlying brain tumors at 2 and 12 months and a third at 6 weeks due to progressive idiopathic renal vein and IVC thrombosis. The remaining five patients were all alive and well at follow-up without evidence of IVC thrombosis, pulmonary emboli, or filter migration. Conclusion: IVC filter placement using available devices for percutaneous delivery is technically feasible, safe, and effective in children.« less
Durack, Jeremy C; Westphalen, Antonio C; Kekulawela, Stephanie; Bhanu, Shiv B; Avrin, David E; Gordon, Roy L; Kerlan, Robert K
2012-04-01
This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Günther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Günther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Günther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Longer indwelling times usually result in vena caval perforation by retrievable Günther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durack, Jeremy C., E-mail: jeremy.durack@ucsf.edu; Westphalen, Antonio C.; Kekulawela, Stephanie
Purpose: This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Guenther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Methods: Guenther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Guenther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissuemore » injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Results: Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Conclusions: Longer indwelling times usually result in vena caval perforation by retrievable Guenther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu; Wagner, Daniel, E-mail: Daniel.Wagner@osumc.edu; Elliott, Eric, E-mail: Eric.Elliott@osumc.edu
PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15more » females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.« less
McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory
2013-11-01
To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.
Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ahmad, Iftikhar; Yeddula, Kalpana; Wicky, Stephan
The purpose of this study was to assess the long-term clinical sequelae of inferior vena cava (IVC) filter thrombus and the effect of anticoagulation on filter thrombus. Of 1,718 patients who had IVC filters placed during 2001-2008, 598 (34.8%) had follow-up abdominal CT. Filter thrombus was seen in 111 of the 598 (18.6%). There were 44 men (39.6%). The mean age at filter placement was 64 years. The medical diseases included cancer in 64, trauma in 15, stroke in 12, and others in 20. The frequency of filter thrombus on CT and asymptomatic filter thrombus on CT was calculated. Themore » frequency of pulmonary embolism (PE) in patients with filter thrombus was calculated. The frequency of thrombus progression or regression (on CT, available in 56) was calculated. The effect of anticoagulation on filter thrombus regression/progression was evaluated using the Fisher exact test by comparing the group of patients who received anticoagulants versus those who did not. A P-value of <0.05 was considered significant. The overall frequency of filter thrombus was 18.6%. Total occlusion of the IVC filter was seen in 12 of 598 (2%). The filter thrombus was asymptomatic in 110 (18.3%). Filter thrombus was detected after a median of 35 days (range, 0-2082) following filter placement. Thrombus extended above the filter in 4 (3.6%); IVC thrombus below the filter was seen in 35(31.5%). Thrombus in the filter occluded <25% of the filter volume in 58 (52.3%), 25-50% in 21 (18.9%), and 50-75% in 20 (18%). Total IVC occlusion was seen in 12 (10.8%). Eighty-three patients received anticoagulation. Sixteen patients developed symptoms of PE. PE was confirmed on CT in 3 of 15 (2.7%). On follow-up, filter thrombus regressed completely in 19 (33.9%) after a median of 6 months. Filter thrombus decreased in size in 13 (23.2%) and it progressed without IVC occlusion in 7 (12.6%). In one (1.7%), filter thrombus progressed to IVC occlusion. Filter thrombus remained stable in 16 (28.6%). There was no significant difference in thrombus regression or progression rates whether or not the patients received anticoagulation for filter thrombus. In conclusion, asymptomatic thrombus in the filter is common and it rarely progresses to complete caval occlusion. Anticoagulation has little effect on the resolution of filter thrombosis and future occurrence of PE.« less
Novel and Advanced Techniques for Complex IVC Filter Retrieval.
Daye, Dania; Walker, T Gregory
2017-04-01
Inferior vena cava (IVC) filter placement is indicated for the treatment of venous thromboembolism (VTE) in patients with a contraindication to or a failure of anticoagulation. With the advent of retrievable IVC filters and their ease of placement, an increasing number of such filters are being inserted for prophylaxis in patients at high risk for VTE. Available data show that only a small number of these filters are retrieved within the recommended period, if at all, prompting the FDA to issue a statement on the need for their timely removal. With prolonged dwell times, advanced techniques may be needed for filter retrieval in up to 60% of the cases. In this article, we review standard and advanced IVC filter retrieval techniques including single-access, dual-access, and dissection techniques. Complicated filter retrievals carry a non-negligible risk for complications such as filter fragmentation and resultant embolization of filter components, venous pseudoaneurysms or stenoses, and breach of the integrity of the caval wall. Careful pre-retrieval assessment of IVC filter position, any significant degree of filter tilting or of hook, and/or strut epithelialization and caval wall penetration by filter components should be considered using dedicated cross-sectional imaging for procedural planning. In complex cases, the risk for retrieval complications should be carefully weighed against the risks of leaving the filter permanently indwelling. The decision to remove an embedded IVC filter using advanced techniques should be individualized to each patient and made with caution, based on the patient's age and existing comorbidities.
NASA Astrophysics Data System (ADS)
Pan, Boan; Liu, Weichao; Fang, Xiang; Zhao, Ke; Li, Ting
2018-02-01
Deep vein thrombosis (DVT), happening in inpatients usually and especially with the postoperative population, is a serious disease characterized by an increased incidence. The venography is the golden standard to diagnose DVT. However, it involves invasive contrast agent injection and give patients physical and mental pressure. Functional nearinfrared spectroscopy (fNIRS) has been reported recently to diagnose DVT. Thrombolytic therapy activates the dissolution system with an exogenous activator that dissolves coronary thrombosis. The vena cava filter is a medical filter used for the treatment of thrombosis and the prevention of pulmonary embolism. Here we attempt to use portable NIRS for the DVT monitoring in the whole process of vena cava filter implantation and thrombolytic treatment, and contrast the patients of untreated, vena cava filter implantation and thrombolytic treatment. 19 DVT patients and 12 normal subjects were recruited. Thereinto, 7 patients have taken vena cava filter implantation, and 6 patients have taken the thrombolytic treatment. It was found that deoxyhemoglobins (Δ[Hb]) fluctuates and even increases in DVT. After vena cava filter implantation, Δ[Hb] increases first, then decreases. However, it emerges the rising trend and converge to the curves of normal subjects in thrombolytic treatment. The oxyhemoglobins (Δ[HbO2]) emerges opposite trend in most paradigms. The findings reveal the potential of fNIRS for monitoring DVT and therapeutic effect evaluation of thrombolysis and vena cava filters.
Aycock, Kenneth I; Campbell, Robert L; Manning, Keefe B; Craven, Brent A
2017-06-01
Inferior vena cava (IVC) filters are medical devices designed to provide a mechanical barrier to the passage of emboli from the deep veins of the legs to the heart and lungs. Despite decades of development and clinical use, IVC filters still fail to prevent the passage of all hazardous emboli. The objective of this study is to (1) develop a resolved two-way computational model of embolus transport, (2) provide verification and validation evidence for the model, and (3) demonstrate the ability of the model to predict the embolus-trapping efficiency of an IVC filter. Our model couples computational fluid dynamics simulations of blood flow to six-degree-of-freedom simulations of embolus transport and resolves the interactions between rigid, spherical emboli and the blood flow using an immersed boundary method. Following model development and numerical verification and validation of the computational approach against benchmark data from the literature, embolus transport simulations are performed in an idealized IVC geometry. Centered and tilted filter orientations are considered using a nonlinear finite element-based virtual filter placement procedure. A total of 2048 coupled CFD/6-DOF simulations are performed to predict the embolus-trapping statistics of the filter. The simulations predict that the embolus-trapping efficiency of the IVC filter increases with increasing embolus diameter and increasing embolus-to-blood density ratio. Tilted filter placement is found to decrease the embolus-trapping efficiency compared with centered filter placement. Multiple embolus-trapping locations are predicted for the IVC filter, and the trapping locations are predicted to shift upstream and toward the vessel wall with increasing embolus diameter. Simulations of the injection of successive emboli into the IVC are also performed and reveal that the embolus-trapping efficiency decreases with increasing thrombus load in the IVC filter. In future work, the computational tool could be used to investigate IVC filter design improvements, the effect of patient anatomy on embolus transport and IVC filter embolus-trapping efficiency, and, with further development and validation, optimal filter selection and placement on a patient-specific basis.
Pilot in vivo study of an absorbable polydioxanone vena cava filter.
Eggers, Mitchell D; McArthur, Mark J; Figueira, Tomas A; Abdelsalam, Mohamed E; Dixon, Katherine P; Pageon, Laura R; Wallace, Michael J; Huang, Steven Y
2015-10-01
The objectives of this study were to evaluate tensile strength retention of polydioxanone as a function of time in a swine venous system and to assess the feasibility of an absorbable inferior vena cava (IVC) filter made from polydioxanone in a pilot swine study. Twenty strands (60 cm each) of size 1 polydioxanone absorbable suture (Ethicon, Somerville, NJ) were placed in the central venous system of domestic swine. Strands were harvested at weekly intervals during 10 weeks for tensile strength testing. Results were compared with control samples obtained from an in vitro engineered circulation system containing sodium phosphate buffer solution. Three IVC filters braided from polydioxanone suture were also catheter deployed in three swine to assess absorbable IVC filter feasibility. Polydioxanone retained 82% tensile strength in vitro vs 79% in vivo at 35 days (P > .22), the desired prophylactic duration. For IVC filters made from polydioxanone, technical success of placement was achieved in all three filters deployed (100%). Autologous thrombus deployed inferior to the filter remained trapped in the filter until thrombus resorption, with no evidence of pulmonary emboli on follow-up computed tomography. There were no instances of caval penetration, filter-induced IVC thrombosis, filter migration, or tilt >15 degrees with imaging and clinical follow-up carried out to 32 weeks. Strength retention of polydioxanone suture placed in the venous system of swine is similar to earlier in vitro studies out to 10 weeks (P > .06 for all weeks) and is more than sufficient (8.20 ± 0.37 kg mean load at break for size 1) to trap thrombus. Pilot animal study suggests that an absorbable polydioxanone IVC filter can be catheter deployed to capture and to hold iatrogenically administered autologous thrombus through resorption. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.
Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel
2015-12-01
We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.
Impact of consensus statements and reimbursement on vena cava filter utilization.
Desai, Sapan S; Naddaf, Abdallah; Pan, James; Hood, Douglas; Hodgson, Kim J
2016-08-01
Pulmonary embolism is the third most common cause of death in hospitalized patients. Vena cava filters (VCFs) are indicated in patients with venous thromboembolism with a contraindication to anticoagulation. Prophylactic indications are still controversial. However, the utilization of VCFs during the past 15 years may have been affected by societal recommendations and reimbursement rates. The aim of this study was to evaluate the impact of societal guidelines and reimbursement on national trends in VCF placement from 1998 to 2012. The National Inpatient Sample was used to identify patients who underwent VCF placement between 1998 and 2012. VCF placement yearly rates were evaluated. Societal guidelines and consensus statements were identified using a PubMed search. Reimbursement rates for VCF were determined on the basis of published Medicare reports. Statistical analysis was completed using descriptive statistics, Fisher exact test, and trend analysis using the Mann-Kendall test and considered significant for P < .05. The use of VCFs increased 350% between January 1998 and January 2008. Consensus statements in favor of VCFs published by the Eastern Association for the Surgery of Trauma (July 2002) and the Society of Interventional Radiology (March 2006) were temporally associated with a significant 138% and 122% increase in the use of VCFs, respectively (P = .014 and P = .023, respectively). The American College of Chest Physicians guidelines (February 2008 and 2012) discouraging the use of VCFs were preceded by an initial stabilization in the use of VCFs between 2008 and 2012, followed by a 16% decrease in use starting in March 2012 (P = .38). Changes in Medicare reimbursement were not followed by a change in VCF implantation rates. There is a temporal association between the societal guidelines' recommendations regarding VCF placement and the actual rates of insertion. More uniform consensus statements from multiple societies along with the use of level I evidence may be required to lead to a definitive change in practice. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Köcher, Martin; Krcova, Vera; Cerna, Marie; Prochazka, Martin
2009-04-01
To evaluate the feasibility and efficacy of the retrievable Günther Tulip Vena Cava Filter in the prevention of pulmonary embolism in patients with acute deep vein thrombosis in the perinatal period and to discuss the technical demands associated with the filter's implantation and retrieval. Between 1996 until 2007, eight women (mean age 27.4 years, range 20-42 years) with acute deep iliofemoral venous thrombosis in the perinatal period of pregnancy and increased risk of pulmonary embolism during delivery were indicated for retrievable Günther Tulip Vena Cava Filter implantation. All filters were inserted and removed under local anesthesia from the jugular approach. The Günther Tulip Vena Cava Filter was implanted suprarenally in all patients on the day of caesarean delivery. In follow-up cavograms performed just before planned filter removal, no embolus was seen in the filter in any patient. In all patients the filter was retrieved without complications on the 12th day after implantation. Retrievable Günther Tulip Vena Cava Filters can be inserted and removed in patients during the perinatal period without major complications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Looby, S.; Given, M.F.; Geoghegan, T.
Purpose. We evaluated the Gunther Tulip (GT) retrievable inferior vena cava (IVC) filter with regard to indications, filtration efficacy, complications, retrieval window, and use of anticoagulation. Method. A retrospective study was performed of 147 patients (64 men, 83 women; mean age 58.8 years) who underwent retrievable GT filter insertion between 2001 and 2005. The indications for placement included a diagnosis of pulmonary embolism or deep venous thrombosis with a contraindication to anticoagulation (n = 68), pulmonary embolism or deep venous thrombosis while on anticoagulation (n = 49), prophylactic filter placement for high-risk surgical patients with a past history of pulmonarymore » embolism or deep venous thrombosis (n = 20), and a high risk of pulmonary embolism or deep venous thrombosis (n = 10). Forty-nine of the 147 patients did not receive anticoagulation (33.7%) while 96 of 147 patients did, 82 of these receiving warfarin (56.5%), 11 receiving low-molecular weight heparins (7.58%), and 3 receiving antiplatelet agents alone (2.06%). Results. Filter placement was successful in 147 patients (100%). Two patients had two filters inserted. Of the 147 patients, filter deployment was on a permanent basis in 102 and with an intention to retrieve in 45 patients. There were 36 (80%) successful retrievals and 9 (20%) failed retrievals. The mean time to retrieval was 33.6 days. The reasons for failed retrieval included filter struts tightly adherent to the IVC wall (5/9), extreme filter tilt (2/9), and extensive filter thrombus (2/9). Complications included pneumothorax (n = 4), failure of filter expansion (n = 1), and breakthrough pulmonary embolism (n = 1). No IVC thrombotic episodes were recorded. Discussion. The Gunther Tulip retrievable filter can be used as a permanent or a retrievable filter. It is safe and efficacious. GT filters can be safely retrieved at a mean time interval of 33.6 days. The newly developed Celect filter may extend the retrieval interval.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buecker, Arno; Neuerburg, Joerg; Schmitz-Rode, Thomas
1997-11-15
Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombusmore » were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.« less
Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.
Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M
2017-08-01
Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.
Allen, Todd L; Carter, Jody L; Morris, Brad J; Harker, Colleen P; Stevens, Mark H
2005-06-01
Venous thromboembolic (VTE) disease remains a significant cause of morbidity for trauma patients because many patients have injuries that may preclude effective VTE prevention and treatment. Retrievable vena cava filters may prove beneficial in this subset of trauma patients. Trauma patients at risk for VTE were identified and managed by institutional protocol. Patients who required a vena cava filter were managed with a device that could be retrieved or left in situ. A retrospective review of medical records was used to identify the use, indications, and complications associated with a retrievable filter. Fifty-three retrievable filters were placed in 51 patients. Two of these patients received a second filter, and 1 received a filter in the superior vena cava. Thirty-two filters were placed prophylactically, whereas 21 were placed for demonstrated venous thromboembolism (VTE). Retrieval was successful in 24 of 25 attempts. Twenty-nine filters became permanent: 10 for continued contraindications to anticoagulation without known VTE, 12 for known VTE and continued contraindications to anticoagulation, 1 for technical reasons, and 6 because of patient death. There were no complications of bleeding, device migration or thrombosis, infection, or pulmonary embolism. A retrievable vena cava filter appears safe and effective for the prevention of pulmonary embolism in the high-risk trauma patient who cannot receive anticoagulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaber, Mohammad R., E-mail: raffatj@msn.co; Thomson, Matthew J.; Smith, Douglas C.
We describe percutaneous, translumbar placement of a 14-Fr dialysis catheter into an ascending lumbar vein to achieve tip position in an enlarged azygos vein. The patient had thrombosis of all traditional vascular sites, as well as the inferior vena cava. This catheter functioned well for 7 months before fatal catheter-related infection developed.
Inferior Vena Cava Filters in Patients with Acute Pulmonary Embolism and Cancer.
Stein, Paul D; Matta, Fadi; Lawrence, Frank R; Hughes, Mary J
2018-04-01
Administrative data have shown a lower mortality in hospitalized patients with pulmonary embolism and cancer who receive a vena cava filter. In the absence of a randomized controlled trial of vena cava filters in such patients, further investigation is necessary. Therefore, we performed this investigation using administrative data from a different database than used previously, and we investigate patients hospitalized in more recent years. We analyzed administrative data from the Premier Healthcare Database, 2010-2014, in patients hospitalized with pulmonary embolism and solid malignant tumors. Patients were identified on the basis of International Classification of Disease, Ninth Revision, Clinical Modification codes. Patients aged >60 years had a lower in-hospital all-cause mortality with vena cava filters than those who did not have filters, 346 of 4648 (7.4%) compared with 2216 of 19,847 (11.2%) (P < .0001) (relative risk 0.67). Among patients aged >60 years who received an inferior vena cava, all-cause mortality within 3 months was 704 of 4648 (15.1%), compared with 3444 of 19,847 (17.4%) among those who did not receive a filter (P < .0001) (relative risk 0.86). Elderly patients with pulmonary embolism and cancer may be a special population in whom inferior vena cava filters reduce in-hospital and 3-month all-cause mortality. Further investigation is needed, particularly in younger patients. Copyright © 2018. Published by Elsevier Inc.
Chow, Felix Che-Lok; Chan, Yiu-Che; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung
2015-07-01
Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE), especially in patients with active contraindication to systemic anticoagulation. The aim of this study is to examine the outcomes of patients who received permanent IVC filters at our institution. This is a single-center retrospective observational study with review of a prospectively collected database for patients who had permanent IVC filters. Patient demographics, indications of filter placement, postprocedure clinical outcome and complications, as well as use of anticoagulant therapy were documented. Chi-squared test was used to test for statistically significant differences (IBM SPSS version 21; IBM Corp., Armonk, NY), while survival was calculated using Kaplan-Meier survival curves analysis. Between February 1998 and December 2013, a total of 109 patients with a median age of 65 (47 men, range 19-97) years had IVC filters inserted at our institution. All of them had documented venous thromboembolism (VTE) before filter placement: 99 (90.8%) had lower extremity deep vein thrombosis (DVT) (including 34 iliac, 65 infrainguinal), 9 (8.3%) had massive PE without evidence of lower limb DVT, and 1 (0.9%) had isolated IVC thrombosis. Forty-seven (43.1%) patients had PE before filter insertion. There were 2 serious procedure-related complications: one access site thrombosis and one right ventricular perforation. With a mean follow-up of 36 ± 33 months, no patient had further symptomatic PE or paradoxical embolism. There were a total of 54 (49.5%) deaths, with a 30-day mortality of 8.3%; none of them was device or procedure related. Among the 92 patients followed up, 27 (29.3%) had further VTE-either DVT in the index or the contralateral lower limb (20 patients, 21.7%), or thrombus inside the filter or the IVC (14 patients, 15.2%). Forty-one (44.6%) patients reported post-thrombotic syndrome (PTS) symptoms. Anticoagulant therapy was given to 39 (42.4%) and 55 (59.8%) patients in the periprocedural period and at any time during the study period, respectively. It did not reduce the rate of postfilter VTE or PTS in both instances. None of the filters in this series was retrieved. This observational study showed that IVC filters were effective in the prevention of PE, although symptomatic postfilter VTE and PTS were common, leading to significant morbidity. Patients who received permanent filters have high mortality on follow-up; however, none were procedure or device related. Copyright © 2015 Elsevier Inc. All rights reserved.
Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran
2015-01-01
Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846
Multicenter Trial of the VenaTech Convertible Vena Cava Filter.
Hohenwalter, Eric J; Stone, James R; O'Moore, Paul V; Smith, Steven J; Selby, J Bayne; Lewandowski, Robert J; Samuels, Shaun; Kiproff, Paul M; Trost, David W; Madoff, David C; Handel, Jeremy; Gandras, Eric J; Vlahos, Athanasios; Rilling, William S
2017-10-01
To demonstrate rates of successful filter conversion and 6-month major device-related adverse events in subjects with converted caval filters. An investigational device exemption multicenter, prospective, single-arm study was performed at 11 sites enrolling 149 patients. The VenaTech Convertible Vena Cava Filter (B. Braun Interventional Systems, Inc, Bethlehem, Pennsylvania) was implanted in 149 patients with venous thromboembolism and contraindication to or failure of anticoagulation (n = 119), with high-risk trauma (n = 14), and for surgical prophylaxis (n = 16). When the patient was no longer at risk for pulmonary embolism as determined by clinical assessment, an attempt at filter conversion was made. Follow-up of converted patients (n = 93) was conducted at 30 days, 3 months, and 6 months after conversion. Patients who did not undergo a conversion attempt (n = 53) had follow-up at 6 months after implant. All implants were successful. One 7-day migration to the right atrium required surgical removal. Technical success rate for filter conversion was 92.7% (89/96). Mean time from placement to conversion was 130.7 days (range, 15-391 d). No major conversion-related events were reported. The mean conversion procedure time was 30.7 minutes (range, 7-135 min). There were 89 converted and 32 unconverted patients who completed 6-month follow-up with no delayed complications. The VenaTech Convertible filter has a high conversion rate and low 6-month device-related adverse event rate. Further studies are necessary to determine long-term safety and efficacy in both converted and unconverted patients. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Are retrievable vena cava filters placed in trauma patients really retrievable?
Leeper, W R; Murphy, P B; Vogt, K N; Leeper, T J; Kribs, S W; Gray, D K; Parry, N G
2016-08-01
Concerns have arisen regarding the use of retrievable inferior vena cava filters (rIVCFs) in trauma patients due to increasing reports of low retrieval rates. We hypothesized that complete follow-up with a dedicated trauma nurse practitioner would be associated with a higher rate of retrievability. This study was undertaken to determine the rate of retrievability of rIVCFs placed in a Canadian Lead Trauma Centre, and to compare the rate of retrievability in our trauma population to our non-trauma patients. We performed a retrospective cohort study of all patients with rIVCF placed between Jan 1 2000 and June 30 2014. Data were collected on demographics, indication for filter placement, retrieval status, and reasons for non-retrieval. Comparison was made between trauma patients and non-trauma patients. A total of 374 rIVCFs were placed (61 in trauma patients and 313 in non-trauma patients) and follow-up was complete for the entire cohort. Filter retrieval was achieved in 86.9 % of trauma patients. Reasons for non-retrieval were technical in two patients, and death before retrieval in six patients. Retrieval was successful in 48.9 % of non-trauma patients. This study demonstrates that rIVCFs can be successfully retrieved amongst trauma patients. We demonstrated a higher rate of successful retrieval amongst trauma patients than non-trauma patients in our institution. Careful patient follow-up may play a role in successful retrieval of rIVCFs.
Carlin, Margo Nicole; Daneshpajouh, Alireza; Catino, Joseph; Bukur, Marko
2017-12-01
Inferior vena cava filters (IVCF) for venous thromboembolic prophylaxis in high-risk trauma patients is a controversial practice. Utilization of IVCF prophylaxis was evaluated at a level 1 trauma center. Daily cost of IVCF prophylaxis, time to IVCF, duration between IVCF and chemoprophylaxis, and number of patients needed to treat (NNT) to prevent pulmonary embolism (PE) was calculated. A retrospective review of prophylactic IVCF over a 5-year period (2010-2014). Demographic, physiologic, injury, procedural, and outcome data were abstracted from the administrative trauma database. Medicare fees and days without chemoprophylaxis were used to determine daily IVCF cost. NNT was calculated using PE events in a cohort without IVCF. Over the 5-year period, 146 patients with mean age 56.3 y (SD ± 24.2), 67.8% male, underwent prophylactic IVCF. Predominant mechanisms of injuries were falls (45.9%) and motor vehicle accidents (20.5%) with median Injury Severity Score of 25 (intraquartile range [IQR] 16-29) and head Abbreviated Injury Score of 3 (IQR 3-5). Most common operative interventions required in 24.7% were orthopedic (25.3%) and neurosurgical (21.9%). Median time to IVCF was 78 h (IQR 48-144). Most common IVCF indications were closed head injury (48.6%) and spinal injuries (30.8%). Median time to administration of chemoprophylaxis was 96 h after IVCF (IQR 24-192) in 57.5%. Median IVCF cost was $759/d (IQR $361-$1897) compared with $4.32 for chemoprophylaxis. PE occurred in 0.26% without IVCF. PE did not occur with prophylactic IVCF. Estimated NNT was 379 (95% CI 265, 661). Prophylactic IVCF placement is a costly practice with relatively low benefit. Anticipated time without chemoprophylaxis and patient criteria should be considered before routine IVCF placement. Copyright © 2017 Elsevier Inc. All rights reserved.
Charlton-Ouw, Kristofer M; Leake, Samuel S; Sola, Cristina N; Sandhu, Harleen K; Albarado, Rondel; Holcomb, John B; Miller, Charles C; Safi, Hazim J; Azizzadeh, Ali
2015-01-01
Considering new guidelines for retrievable inferior vena cava filters (IVCFs), we examine our initial experience after establishing a comprehensive filter removal program in our level 1 trauma center. We evaluated the technical and financial feasibility of this program and barriers to IVCF retrieval, including insurance status and costs, in trauma patients. Trauma patients receiving IVCFs from May 2011 to 2013 were consented and prospectively enrolled in the study program. Retrieval rates were assessed for the years before study initiation. Primary outcome was IVCF retrieval. Hospital financial data for retrieval were examined and univariate analysis performed. Hospital cost-to-charge and payment-to-charge ratios were assessed. Before study initiation from April 2009 to 2011, 66 IVCFs were placed in trauma patients with only 2 retrievals in 2 years. During the study period, 247 trauma patients had IVCF placement of which 111 (45%) were enrolled. The main reason for nonenrollment was lack of referral by the implanting team. Retrieval was attempted in 100 outpatients with success in 85 (85%). Patients enrolled in the program were more likely to have their filters removed (73% vs. 18%; odds ratio, 12.6; 95% confidence interval, 6.6-24.3; P < 0.001). Mean time from placement to attempt was 6.2 ± 4.0 months (range, 0.5-31.8). Of the total attempts, 29% were nonresource patients, 11% had Medicaid, and 60% had commercial insurance including Medicare patients. Chances of successful retrieval were higher if performed later during the study (P = 0.03). Successful retrieval was not related to insurance status (P = not significant). The mean total hospital charges related to retrieval were $4,493 (range, $2,510-$9,106). Successful retrieval contributed to lower total charges (P < 0.01). Factors contributing to higher total charges were retrieval attempt later in study period (P = 0.01) and commercial insurance status (P = 0.04). The rate of IVCF placement in trauma patients increased 4-fold over 4 years. The rate of IVCF retrieval increased more than 14-fold during the same period after establishment of the retrieval program. Elective outpatient retrieval of IVCFs in all eligible trauma patients is financially feasible without loss to the health care system even in regions with high rates of uninsured. A major barrier to successful filter retrieval was lack of patient referral into the program by implanting physicians. Hospital administration and physician outreach are important determinants of successful IVCF retrieval in trauma patients. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.
2004-01-15
We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.
Modeling Flow Past a Tilted Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Wang, S L
Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside amore » model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.« less
[How efficient and safe are Vena-cava-filters?].
Kluge, Stefan
2015-08-01
In the last 30 years patients with pulmonary embolism have increasingly often been implanted with a vena cava filter. Evidence of safety and efficacy in comparison to pure anticoagulation are in short supply. Re-removable filter reduces neither the risk of recurrence nor mortality, according to a study now revealed.
Sabharwal, Samir; Fox, Adam D; Vives, Michael J
2018-05-07
Objective To determine the prevalence and variation of inferior vena cava filter (IVCF) use in the spine trauma population and evaluate patient and facility level factors associated with their use. Study Design Retrospective cohort. Participants/Outcome Measures Patients with spinal injuries were identified by ICD-9 codes from the National Trauma Data Bank (NTDB), the best validated national trauma database. Patients whose spine injuries were operatively treated and those who received IVCF were identified from procedure description fields. Additional information compiled included patient demographics, injury severity score (ISS), time until surgery, concomitant fractures, and facility level information. Multivariate logistic regression analyses were conducted to examine the relationship of associated factors for IVCF use. Results Of the 120,920 patients identified with spinal injuries, 2.4% received prophylactic IVCF. Of the 13,273 patients with operatively treated spinal injuries, 8.2% received prophylactic IVCF. Of the 7,770 patients with spinal cord injury (SCI), 10.8% received prophylactic IVCF. The interquartile ranges of placement rates among centers demonstrated greater than 10 fold variation. Based on multivariate logistic regression, ISS score >12 demonstrated the strongest association with prophylactic IVCF (adjusted OR = 4.908). Concomitant pelvic and lower extremity fractures (adj OR 2.573 and 2.522) were also associated with their use. Conclusions Currently the only data regarding existing IVCF use in the spine trauma population amounts to surveys. The present study provides the most detailed and objective information regarding their use in this setting. Even in the operatively treated and SCI subgroups, prophylactic filters were used in only a small percentage of cases but placement rates varied widely among centers. More severely injured patients (ISS >12) had highest odds of receiving prophylactic IVCF. Further study is needed to clarify their role in this vulnerable population.
Jia, Zhongzhi; Fuller, Tyler A; McKinney, J Mark; Paz-Fumagalli, Ricardo; Frey, Gregory T; Sella, David M; Van Ha, Thuong; Wang, Weiping
2018-05-01
To investigate the use of retrievable inferior vena cava (IVC) filters in the current practice and analyze the causes of filter left in situ despite initial plans for retrieval. A systematic search of all English-language studies of retrievable IVC filters was conducted, including clinical trials and observational studies published between January 1984 and March 2016. A total of 103 studies were identified, including 10 filter models in 20,319 patients. Placement indications were reported for 11,128 (54.8%) patients, including therapeutic (n = 6270; 56.3%) and prophylactic (n = 4858; 43.7%) indications. A total of 13,224 (65.1%) filters were left as permanent devices; 7095 (34.9%) filters were removed. The reasons for filter nonretrieval among the 5308 (40.1%) reported cases were primary permanent indication (21.2%; 1127/5308), death (19.4%; 1031/5308), ongoing pulmonary embolism (PE) protection (19.0%; 1011/5308), failed retrieval (13.7%; 725/5308), loss to follow-up (13.0%; 689/5308), discontinued care (4.4%; 235/5308), physician oversight (4.0%; 213/5308), patient morbidity (2.8%; 149/5308), and patient refusal (2.4%; 128/5308). A total of 7820 patients presented for filter retrieval, and 7095 filters (90.7%) were successfully removed, with a mean indwelling time of 106.6 ± 47.3 days. Breakthrough PE was reported in 2.1% (191/9169) of patients. Filter tilt, recurrent deep vein thrombosis, penetration, IVC thrombosis, migration, and fracture occurred in 7.7% (798/10,348), 7.1% (362/5092), 5.4% (379/7001), 3.9% (345/8788), 1.4% (160/11,679), and 0.5% (50/9509) of patients, respectively. Approximately two-thirds of retrievable filters were not retrieved even though more than 85% of the filters were initially intended for temporary use. The major reasons for filter left in situ despite initial plans for retrieval were death, need for ongoing PE protection, failed retrieval, loss to follow-up, discontinued care, and physician oversight.
Inferior vena cava filters in pulmonary embolism: A historic controversy.
Jerjes-Sanchez, Carlos; Rodriguez, David; Navarrete, Aline; Parra-Cantu, Carolina; Joya-Harrison, Jorge; Vazquez, Eduardo; Ramirez-Rivera, Alicia
Rationale for non-routine use of inferior venous cava filters (IVCF) in pulmonary embolism (PE) patients. Thrombosis mechanisms involved with IVCF placement and removal, the blood-contacting medical device inducing clotting, and the inorganic polyphosphate in the contact activation pathway were analyzed. In addition, we analyzed clinical evidence from randomized trials, including patients with and without cancer. Furthermore, we estimated the absolute risk reduction (ARR), the relative risk reduction (RRR), and the number needed to treat (NNT) based on the results of each study using a frequency table. Finally, we analyzed the outcome of our PE patients that were submitted to thrombolysis with short and long term follow-up. IVCF induces thrombosis by several mechanisms including placement and removal, rapid protein adsorption, and simultaneous surface-induced activation via the contact activation pathway. Also, inorganic polyphosphate has an important role as a procoagulant, reversing the effect of anticoagulants. Randomized control trials included 904 cancer and non-cancer PE patients. In terms of ARR, RRR, and NNT, there is no evidence for routine use of IVCF. In 290 patients with proved PE, extensive thrombotic burden and right ventricular dysfunction under thrombolysis and oral anticoagulation, we observed a favorable outcome in a short- and long-term follow-up; additionally, IVCF was only used in 5% of these patients. Considering the complex mechanisms of thrombosis related with IVCF, the evidence from randomized control trials and ARR, RRR, and NNT obtained from venous thromboembolism patients with and without cancer, non-routine use of IVCF is recommended. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Design Optimization of Vena Cava Filters: An application to dual filtration devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Wang, S L; Diachin, D P
Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped modelmore » thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.« less
Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com
Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less
A Novel Technique for Inferior Vena Cava Filter Extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn
Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.
Petridis, Ioannis; Miraglia, Roberto; Marrone, Gianluca; Gruttadauria, Salvatore; Luca, Angelo; Vizzini, Giovanni Battista; Gridelli, Bruno
2010-03-07
Transjugular intrahepatic portosystemic shunt (TIPSS) is considered a valid therapeutic option for the treatment of portal hypertension and its complications. The guidelines for this procedure have already been established on the basis of the normal vascular anatomy and of various technical radiological aspects. In some few rare cases, diagnosis of a congenital vascular anomaly can be made accidentally by interventional radiologists, making the procedure of the TIPSS placement extremely difficult or in some cases technically impossible. This report describes a rare vascular malformation characterized by the absence of the right superior vena cava and persistence of the left superior vena cava in a patient with a diagnosis of advanced liver cirrhosis who needed a TIPSS placement in order to control refractory ascites.
Inferior Vena Cava Filters in Elderly Patients with Stable Acute Pulmonary Embolism.
Stein, Paul D; Matta, Fadi; Hughes, Mary J
2017-03-01
Patients aged >60 years with pulmonary embolism who were stable and did not require thrombolytic therapy were shown to have a somewhat lower in-hospital all-cause mortality with vena cava filters. In this investigation we further assess mortality with filters in stable elderly patients. In-hospital all-cause mortality according to use of inferior vena cava filters was assessed from the National (Nationwide) Inpatient Sample, 2003-2012, in: 1) All patients with pulmonary embolism; 2) All with pulmonary embolism who had none of the comorbid conditions listed in the Charlson Comorbidity Index; 3) Patients with a primary (first-listed) diagnosis of pulmonary embolism, and 4) Patients with a primary diagnosis of pulmonary embolism and none of the comorbid conditions listed in the Charlson Comorbidity Index. From 2003-2012, 2,621,575 stable patients with pulmonary embolism were hospitalized in the US. Patients aged >80 years showed lower mortality with vena cava filters (all pulmonary embolism, 6.1% vs 10.5%; all pulmonary embolism with no comorbid conditions, 3.3% vs 6.3%; primary pulmonary embolism, 4.1% vs 5.7%; primary pulmonary embolism with no comorbid conditions, 2.1% vs 3.7%; all P <.0001). In the all-patient category, patients aged 71-80 years showed somewhat lower mortality with filters, 6.3% vs 7.4% (P <.0001), and those without comorbid conditions, 2.5% vs 2.8% (P = .04). Those aged 71-80 years with primary pulmonary embolism, irrespective of comorbid conditions, did not show lower mortality with filters. At present, in the absence of a randomized controlled trial, it seems prudent to consider a vena cava filter in very elderly (aged >80 years) stable patients with acute pulmonary embolism. Copyright © 2016 Elsevier Inc. All rights reserved.
Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sofue, Keitaro, E-mail: keitarosofue@yahoo.co.jp; Takeuchi, Yoshito, E-mail: yotake62@qg8.so-net.ne.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp
A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wildberger, Joachim Ernst, E-mail: wildberg@rad.rwth-aachen.de; Haage, Patrick; Bovelander, Jan
2005-04-15
Purpose. To evaluate the size and quantity of downstream emboli after thrombectomy using the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with or without temporary filtration for extensive iliofemoral and iliocaval thrombi in an in vitro flow model. Methods. Iliocaval thrombi were simulated by clotted bovine blood in a flow model (semilucent silicone tubings, diameter 12-16 mm). Five experimental set-ups were performed 10 times each; thrombus particles and distribution were measured in the effluent. First, after retrograde insertion, mechanical thrombectomy was performed using the PTD alone. Then a modified self-expanding tulip-shaped temporary vena cava stent filter was inserted additionally at the beginningmore » of each declotting procedure and removed immediately after the intervention without any manipulation within or at the filter itself. In a third step, the filter was filled with thrombus only. Here, two experiments were performed: Careful closure within the flow circuit without any additional fragmentation procedure and running the PTD within the filter lumen, respectively. In the final set-up, mechanical thrombectomy was performed within the thrombus-filled tubing as well as in the filter lumen. The latter was closed at the end of the procedure and both devices were removed from the flow circuit. Results. Running the PTD in the flow circuit without filter protection led to a fragmentation of 67.9% ({+-}7.14%) of the clot into particles {<=}500 {mu}m; restoration of flow was established in all cases. Additional placement of the filter safely allowed maceration of 82.9% ({+-}5.59%) of the thrombus. Controlled closure of the thrombus-filled filter within the flow circuit without additional mechanical treatment broke up 75.2% ({+-}10.49%), while additional mechanical thrombectomy by running the PTD within the occluded filter led to dissolution of 90.4% ({+-}3.99%) of the initial clot. In the final set-up, an overall fragmentation rate of 99.6% ({+-}0.44%) was achieved. Conclusions. The combined use of the Arrow-Trerotola PTD and a temporary vena cava stent filter proved to be effective for even large clot removal in this experimental set-up.« less
Kang, Jieun; Kim, Seon Ok; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2018-05-17
Malignancy is associated with an increased risk of venous thromboembolism. Inferior vena cava filters are a viable alternative when anticoagulation is infeasible because of the risk of bleeding. Although the current guidelines recommend that all patients with a vena cava filter be treated with anticoagulation treatment when the risk of bleeding is reduced, studies concerning the role of concomitant anticoagulation after vena cava filter insertion in high-risk patients are scarce. Since many cancer patients suffer from a high risk of hemorrhagic complications, we aimed to determine the effect of post-filter anticoagulation on mortality in patients with a malignant solid tumor. A retrospective cohort study of patients with pulmonary embolism was performed between January 2010 and May 2016. Patients with a solid tumor and vena cava filter inserted because of pulmonary embolism were included. Using Cox proportional hazards model, the prognostic effect of clinical variables was analyzed. A total of 180 patients were analyzed, with 143 patients receiving and 37 patients not receiving post-filter anticoagulation treatment. Mortality was not significantly different between the two groups. The presence of metastatic cancer and that of pancreatobiliary cancer were significant risk factors for mortality. However, post-filter anticoagulation did not show significant effect on mortality regardless of the stage of cancer. In patients with cancer-associated pulmonary embolism, the effect of post-filter anticoagulation on mortality may not be critical, especially in patients with a short life expectancy.
Percutaneous retrieval of a right atrioventricular embolus.
Davies, R P; Harding, J; Hassam, R
1998-01-01
Percutaneous retrieval of a 12-cm-long serpiginous clot lodged in the right atrium and ventricle is reported. Following bilateral common femoral vein puncture, a Bird's Nest cava filter was first positioned ready to deploy immediately below the renal veins via the right femoral vein. From the left femoral vein, a Cook intravascular retrieval basket was advanced to the right atrium. Under transthoracic echocardiographic visualization, the basket was used to engage, trap, and gently withdraw the clot in a single long strand below the prepositioned inferior vena cava filter. The filter was immediately deployed, leaving the clot trapped inferior to the renal veins, in the cava and left iliac vein. The patient remained well and asymptomatic at discharge.
Inferior Vena Cava Filters: Current and Future Concepts.
Kaufman, John Andrew
2018-01-01
The inferior vena cava filter clinical environment is notable for the degree of controversy, uncertainty, and fear associated with these devices by both physicians and the public. This article reviews some of the more important current issues with these devices as well as emerging and future trends. Copyright © 2017 Elsevier Inc. All rights reserved.
Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahrer, Arie; Zippel, Douglas; Garniek, Alexander
The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavographymore » prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.« less
Son, Joohyung; Bae, Miju; Chung, Sung Woon; Lee, Chung Won; Huh, Up; Song, Seunghwan
2017-12-01
The inferior vena cava filter (IVCF) is very effective for preventing pulmonary embolism in patients who cannot undergo anticoagulation therapy. However, if a filter is placed in the body permanently, it may lead to other complications. A retrospective study was performed of 159 patients who underwent retrievable Cook Celect IVCF implantation between January 2007 and April 2015 at a single center. Baseline characteristics, indications, and complications caused by the filter were investigated. The most common underlying disease of patients receiving the filter was cancer (24.3%). Venous thrombolysis or thrombectomy was the most common indication for IVCF insertion in this study (47.2%). The most common complication was inferior vena cava penetration, the risk of which increased the longer the filter remained in the body (p=0.032, Exp(B)=1.004). If the patient is able to retry anticoagulation therapy and the filter is no longer needed, the filter should be removed, even if a long time has elapsed since implantation. If the filter cannot be removed, it is recommended that follow-up computed tomography be performed regularly to monitor the progress of venous thromboembolisms as well as any filter-related complications.
Can Patients Comprehend the Educational Materials that Hospitals Provide about Common IR Procedures?
Sadigh, Gelareh; Hawkins, C Matthew; O'Keefe, John J; Khan, Ramsha; Duszak, Richard
2015-08-01
To assess the readability of online education materials offered by hospitals describing commonly performed interventional radiology (IR) procedures. Online patient education materials from 402 hospitals selected from the Medicare Hospital Compare database were assessed. The presence of an IR service was determined by representation in the Society of Interventional Radiology physician finder directory. Patient online education materials about (i) uterine artery embolization for fibroid tumors, (ii) liver cancer embolization, (iii) varicose vein treatment, (iv) central venous access, (v) inferior vena cava (IVC) filter placement, (vi) nephrostomy tube insertion, (vii) gastrostomy tube placement, and (viii) vertebral augmentation were targeted and assessed by using six validated readability scoring systems. Of 402 hospitals sampled, 156 (39%) were presumed to offer IR services. Of these, 119 (76%) offered online patient education material for one or more of the eight service lines. The average readability scores corresponding to grade varied between the ninth- and 12th-grade levels. All were higher than the recommended seventh-grade level (P < .05) except for nephrostomy and gastrostomy tube placement. Average Flesch-Kincaid Reading Ease scores ranged from 42 to 69, corresponding with fairly difficult to difficult readability for all service lines except IVC filter and gastrostomy tube placement, which corresponded with standard readability. A majority of hospitals offering IR services provide at least some online patient education material. Most, however, are written significantly above the reading comprehension level of most Americans. More attention to health literacy by hospitals and IR physicians is warranted. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalva, Sanjeeva P., E-mail: skalva@partners.org; Athanasoulis, Christos A.; Fan, C.-M.
The purpose of the study was to assess the clinical safety and efficacy of the 'Recovery{sup TM}' (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a 'Recovery{sup TM}' IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. 'Recovery' filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean:more » 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following 'Recovery' filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.« less
Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A
2017-06-01
This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
CT of inferior vena cava filters: normal presentations and potential complications.
Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man
2015-12-01
With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.
Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, M A; Henshaw, W D; Wang, S L
To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flowmore » in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating/stagnant flow with very low shear stress that may be thrombogenic.« less
Guide wire entrapment by inferior vena cava filters: an experimental study.
Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F
2005-09-01
In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.
The Mid-Term Efficacy and Safety of a Permanent Nitinol IVC Filter (TrapEase)
Liu, Wei Chiang; Choo, Sung Wook; Kim, Dong-Ik; Kim, Young Wook; Kim, Duk-Kyung; Shin, Sung Wook; Park, Kwang Bo; Jeon, Yong Hwan; Choo, In-Wook
2005-01-01
Objective 1) To evaluate the mid-term efficacy and safety of a permanent nitinol inferior vena cava (IVC) filter; 2) to evaluate filter effectiveness, filter stability and caval occlusion. Materials and Methods A prospective evaluation of the TrapEase IVC filter was performed on 42 patients (eight men, 34 women) ranging in age from 22 to 78 years (mean age 66 years). All patients were ill with a high risk of pulmonary embolism (PE). Indications for filter placement were: 1) deep vein thrombosis with recurrent thromboembolism; 2) and/or free-floating thrombus with contraindication to anticoagulation; and 3) complications in achieving adequate anticoagulation. Follow-up evaluations (mean: 15.4 months, range: 2 to 28 months) were performed at 6- and 12-month intervals after the procedure and included clinical histories, chart reviews, plain film, Doppler ultrasounds, and contrasted abdominal CT scans. Results In follow-up evaluations, the data analysis revealed no cases of symptomatic PE. There were no cases of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study, there was one case of filter thrombosis; early symptomatic thrombosis that was successfully treated in the hospital. Of the 42 subjects, eight died. These deaths were not related to the filter device or the implantation procedure, but to the underlying disease. Conclusion This study demonstrates that the TrapEase permanent IVC filter is a safe and an effective device with low complication rates and is best used in patients with thromboembolic disease with a high risk of PE. PMID:15968150
Nutcracker syndrome and deep venous thrombosis in a patient with duplicated inferior vena cava.
Yoshida, Ricardo de Alvarenga; Yoshida, Winston Bonetti; Costa, Renato Fanchiotti; Nacif, Marcelo Souto; Sobreira, Marcone Lima; Jaldin, Rodrigo Gibin
2016-04-01
Duplicated inferior vena cava is a rare anomaly, and thrombosis in one or both segments is even less frequent. We present a case of deep venous thrombosis of the left lower limb involving the popliteal, femoral, and iliac veins as well as the left segment of the duplicated vena cava and nutcracker syndrome. After catheter-directed thrombolysis complemented by mechanical thrombolysis, the compromised veins had complete revascularization; the nutcracker syndrome was treated with stent placement, followed by the use of anticoagulants. There was technical success and complete recovery of the patient. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laborda, Alicia, E-mail: alaborda@unizar.es; Kuo, William T., E-mail: wkuo@stanford.edu; Ioakeim, Ignatios, E-mail: ignacio.ioakim@hotmail.es
2015-10-15
PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava weremore » measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.« less
Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika
The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%)more » had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).« less
Braile vena cava filter and greenfield filter in terms of centralization.
de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon
2013-01-01
The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry.
Histology of Tissue Adherent to OptEase Inferior Vena Cava Filters Regarding Indwelling Time
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Volkov, Alexander; Garniek, Alexander
The purpose of this paper is to report on the histology of tissues found on retrieved filters with regard to indwelling time. Between February 2006 and January 2007, 28 Optease inferior vena cava filters (Cordis Europa, Roden, The Netherlands) were retrieved from 27 patients. Twenty-two filters were inserted prophylactically for trauma patients and six for patients with venous thromboembolism. Cavography was performed both before and after filter removal to evaluate the presence of thrombi or wall damage. Filters were retrieved with the snare and sheath method. All material adherents to the filters were examined histologically.The mean indwelling time of themore » filters was 24.9 days (range, 6-69 days). Red tissue fragments were seen on all the filters, consistent microscopically with clots and fibrin. On five filters (18%; mean indwelling time, 45.4 days) white tissue consistent with vascular intima was found. All postprocedure cavographies were normal. We conclude that most material adherent to the retrieved filters is thrombi, while vascular intima can be found in the minority of filters with a longer indwelling time.« less
Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701
Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W
2013-01-01
The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.
Braile Vena Cava Filter and Greenfield Filter in Terms of Centralization
de Godoy, José Maria Pereira; Menezes da Silva, Adinaldo A; Reis, Luis Fernando; Miquelin, Daniel; Torati, José Luis Simon
2013-01-01
The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter’s symmetry during implantation and complications experienced during the procedure. All the angiographic examinations performed during the implantation of the filters were analyzed in respect to the following parameters: migration of the filter, non-opening or difficulties in the implantation and centralization of the filter. A total of 112 Braile CVFs were implanted and there were no reports of filter opening difficulties or in respect to migration. Asymmetry was observed in 1/112 (0.9%) cases. A statistically significant difference was seen on comparing historical data on decentralization of the Greenfield filter with the data of this study. The Braile Biomédico filter is an evolution of the Greenfield filter providing improved embolus capture and better implantation symmetry. PMID:23459189
Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro
2008-10-01
A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.
Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir
2016-05-01
To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dutta, Usha; Garg, Pramod K.; Agarwal, Rajeev
1999-11-15
A 31-year-old man presented with idiopathic membranous obstruction of the suprahepatic inferior vena cava (IVC) and was treated by balloon dilation and placement of a Wallstent. The patient improved markedly. However, he developed obstruction of the hepatic vein outflow secondary to neointima formation over the stent that covered the hepatic vein ostia. The patient died of liver failure and septicemia. We believe that this is the first report of such a serious complication.
Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung
2017-12-01
Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cookson, Daniel, E-mail: danielthomascookson@yahoo.co.uk; Caldwell, Stuart, E-mail: stuart.caldwell@middlemore.co.nz
Phlegmasia caerulea dolens (PCD) is a potentially disastrous complication of inferior vena cava filter insertion, and its optimum management has not been clearly established. We present a case report of a patient with pulmonary embolism and acute adrenal haemorrhage who developed PCD secondary to massive iliocaval thrombosis after insertion of a Cook Celect removable filter. Local intravenous catheter-directed thrombolysis (CDT), followed by systemic anticoagulation, achieved limb salvage and virtual resolution of symptoms at 3 months without complications. CDT can be a successful primary treatment of filter-associated PCD and can be safe in selected patients with acute nontraumatic haemorrhage. Systemic anticoagulationmore » may subsequently restore complete venous patency and may therefore be a useful approach to postthrombolysis management of residual iliocaval thrombus when filter removal is indicated.« less
Tam, Matthew D; Spain, James; Lieber, Michael; Geisinger, Michael; Sands, Mark J; Wang, Weiping
2012-02-01
To report the occurrence of fracture of the Recovery filter and incidence of potentially life-threatening complications associated with fractured fragment migration. A retrospective study of images obtained after placement of Recovery inferior vena cava (IVC) filters from 2003 to 2006 was conducted at a single tertiary-care center. Images were reevaluated for fracture and migration; complications related to filter fracture were investigated. Kaplan-Meier survival analysis was performed to investigate the relationship between time in situ and fracture. A total of 363 Recovery filters were placed; 97 were retrieved, leaving 266 filters in situ (135 patients subsequently died of other causes). The following images were evaluated: 130 chest computed tomography (CT) scans, 153 abdominal CT scans, 254 chest radiographs, 148 radiographs of the abdomen/pelvis, and 106 cavagrams. Mean imaging follow-up interval was 18.4 months (maximum, 81.3 mo). No en bloc migration occurred outside the IVC. Twenty-six limb fractures (all short limbs) were identified in 20 patients; the earliest occurred at 4.1 months. Eight fragment migrations occurred into pulmonary arteries, seven into iliac/femoral veins, one into the right ventricle, and one into the renal vein. Seven fragments were intracaval near the filter, one was extracaval, and one could not be located. Kaplan-Meier survival estimates predicted a fracture rate of 40% at 5.5 years. Of the 20 patients with filter fractures, three died of unrelated causes and 17 remain asymptomatic. Recovery filter fractures occurred at the short limb only, with a suggested 5.5-year fracture risk of 40%. No life-threatening events occurred in patients with filter fracture. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.
The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less
Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.
Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H
2018-05-01
This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.
Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki
2014-02-01
Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doody, Orla, E-mail: orla_doody@hotmail.com; Noe, Geertje; Given, Mark F.
Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range,more » 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.« less
Brountzos, Elias N; Binkert, Christoph A; Panagiotou, Irene E; Petersen, Bryan D; Timmermans, Hans; Lakin, Paul C
2004-01-01
We evaluated the clinical outcome of malignant inferior vena cava (IVC) syndrome after intrahepatic IVC stent placement by retrospective analysis of 50 consecutive patients (25 men, 25 women, age 32-83 years) with malignant IVC syndrome who were treated with intrahepatic stent placement. Gianturco-Rosch-Z (GRZ) stents (n = 45), and Wallstents (n = 5) were inserted. Clinical outcome was assessed from patients' records using a score based on leg swelling, scrotal/vulvar edema, ascites and anasarca before and after stent placement, as well as at last follow-up visit before death. Clinical follow-up was supplemented by duplex sonography in 36 patients. Inferior venocavography was performed in 5 patients prior to re- intervention. Follow-up time ranged from 1 to 932 days (mean 62 days). Mean pressure gradient in the IVC was reduced from 14 +/- 4.1 mmHg before to 2.9 +/- 3.2 mmHg after stent placement (p < 0.001). Four patients had stent occlusion, 2 of whom were successfully re-stented. Primary and secondary patency was 59% and 100%, respectively at 540 days. Immediate clinical data were available in 44 patients: 38 improved; 6 did not respond. Last follow-up visit data were available in 36 patients: 24 showed persistent symptom relief till death. All symptom scores were significantly improved after stent placement (p < 0.001) and with the exception of ascites, remained significantly improved (p < 0.05) until the last follow-up. Increased serum bilirubin was a common characteristic of clinical failures and recurrences. Intrahepatic IVC stent placement resulted in significant symptomatic relief in patients with malignant IVC syndrome. Palliation was effective even in patients with a very short life expectancy.
Robotic-Assisted Inferior Vena Cava Filter Retrieval.
Owji, Shahin; Lu, Tony; Loh, Thomas M; Schwein, Adeline; Lumsden, Alan B; Bismuth, Jean
2017-01-01
Although anticoagulation remains the mainstay of therapy for patients with venous thromboembolism, guidelines recommend the use of inferior vena cava (IVC) filters in those who fail anticoagulation or have contraindications to its use. Short-term use of filters has proven effective in reducing the rate of pulmonary embolism. However, their extended use is associated with a variety of complications such as thrombosis, filter migration, or caval perforation, thus making a case for timely filter retrieval. This is the case of a 68-year-old female with a history of chronic oral anticoagulation use for multiple deep venous thrombi (DVT) and pulmonary emboli (PE) who required cervical and thoracic spinal intervention for spondylosis and foramina stenosis. Given her increased risk of recurrent DVT and PE perioperatively, we elected to place a Cook Celect ™ IVC filter (Cook Medical, Bloomington, IN) after oral anticoagulation was stopped for the procedure. Her treatment course was prolonged due to wound-healing complications. We elected to use the Magellan Robotic Catheter System (Hansen Medical, Mountain View, CA) for filter retrieval when she presented 6 months later with caval perforation from the filter struts. With its ease of use, superior mechanical stability, and maneuverability, robot-assisted IVC filter retrieval may be a safer and more reliable substitute for traditional navigation techniques when presented with challenging filter retrievals.
Tasse, Jordan; Borge, Marc; Pierce, Kenneth; Brems, John
2011-01-01
To describe the safety and efficacy of percutaneous transluminal angioplasty and stent placement in patients presenting with suprahepatic inferior vena cava (IVC) outflow compromise in the early postoperative period following orthotopic liver transplantation. Between October 2002 and April 2009, 3 patients presented with IVC outflow compromise in the first 2 months following orthotopic liver transplantation. All 3 underwent percutaneous transluminal angioplasty and stent placement without complication and showed significant clinical improvement at short and intermediate term follow-up. Percutaneous transluminal angioplasty and Gianturco stent placement is a safe and effective treatment for IVC outflow compromise in the early postoperative period following orthotopic liver transplantation.
Extreme premature with persistent left superior vena cava.
Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin
2017-10-01
Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.
Vena Cava 3D Contrast-Enhanced MR Venography: A Pictorial Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin Jiang; Zhou Kangrong; Chen Zuwang
Three-dimensional contrast-enhanced magnetic resonance venography (CE MRV) is a sensitive and accurate method for diagnosing vena cava pathologies. The commonly used indirect approach involves a nondiluted gadolinium contrast agent injected into an upper limb vein or, occasionally, a pedal vein for assessment of the superior or inferior vena cava. In our studies, a coronal 3D fast multi-planar spoiled gradient-echo acquisition was used. A pre-contrast scan was obtained to ensure correct coverage of the region of interest. We initiated contrast-enhanced acquisition 15 sec after the start of contrast agent injection and performed the procedure twice. The image sets were obtained duringmore » two 20-30-sec breath hold, with a breathing rest of 5-6 sec, to obtain the first-pass and delayed arteriovenous phases. For patients with Budd-Chiari syndrome, a third acquisition coinciding with late venous phase was collected to visualize the hepatic veins, which was carried out by one additional acquisition after a 5-6-sec breathing time. This review describes the clinical application of 3D CE MRV in vena cava congenital anomalies, superior and inferior vena cava syndrome, Budd-Chiari syndrome, peripheral vein thrombosis extending to the vena cava, pre-operational evaluation in portosystemic shunting and post-surgical follow-up, and road-mapping for the placement and evaluation of complications of central venous devices.« less
Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type
Deso, Steven E.; Idakoji, Ibrahim A.; Kuo, William T.
2016-01-01
Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90–100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30–50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters. PMID:27247477
Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pellerin, O., E-mail: olivier.pellerin@egp.aphp.f; Barral, F. G.; Lions, C.
Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days)more » through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.« less
IVC filter retrieval in adolescents: experience in a tertiary pediatric center.
Guzman, Anthony K; Zahra, Mahmoud; Trerotola, Scott O; Raffini, Leslie J; Itkin, Maxim; Keller, Marc S; Cahill, Anne Marie
2016-04-01
Inferior vena cava (IVC) filters are commonly implanted with the intent to prevent life-threatening pulmonary embolism in at-risk patients with contraindications to anticoagulation. Various studies have reported increases in the rate of venous thromboembolism within the pediatric population. The utility and safety of IVC filters in children has not yet been fully defined. To describe the technique and adjunctive maneuvers of IVC filter removal in children, demonstrate its technical success and identify complications. A retrospective 10-year review was performed of 20 children (13 male, 7 female), mean age: 15.1 years (range: 12-19 years), who underwent IVC filter retrieval. Eleven of 20 (55%) were placed in our institution. Electronic medical records were reviewed for filter characteristics, retrieval technique, technical success and complications. The technical success rate was 100%. Placement indications included: deep venous thrombosis with a contraindication to anticoagulation (10/20, 50%), free-floating thrombus (4/20, 20%), post-trauma pulmonary embolism prophylaxis (3/20, 15%) and pre-thrombolysis pulmonary patient (1/20, 5%). The mean implantation period was 63 days (range: 20-270 days). Standard retrieval was performed in 17/20 patients (85%). Adjunctive techniques were performed in 3/20 patients (15%) and included the double-snare technique, balloon assistance and endobronchial forceps retrieval. Median procedure time was 60 min (range: 45-240 min). Pre-retrieval cavogram demonstrated filter tilt in 5/20 patients (25%) with a mean angle of 17° (range: 8-40). Pre-retrieval CT demonstrated strut wall penetration and tip embedment in one patient each. There were two procedure-related complications: IVC mural dissection noted on venography in one patient and snare catheter fracture requiring retrieval in one patient. There were no early or late complications. In children, IVC filter retrieval can be performed safely but may be challenging, especially in cases of filter tilt or embedding. Adjunctive techniques may increase filter retrieval rates.
Radical robot-assisted laparoscopic nephrectomy with thrombectomy in the vena cava.
Estébanez Zarranz, J; Belloso Loidi, J; Gutierrez García, M A; Rubio Calaveras, V; Morales Higelmo, G; Melendo Tercilla, P; Busto Leis, L; Sanz Jaka, J P
2018-04-23
Renal cell carcinoma has a natural tendency to extend through the renal vein. When the thrombus reaches the vena cava, thrombectomy and the necessary reconstruction of the vena cava are typically performed by open pathway. Robot-assisted technology provides advantages for performing this complex technique, using a minimally invasive access. We present the technique we employed in the first case performed in our department. After performing renal artery embolisation, we conducted the surgery with the Vinci S robotic system. The main steps of the surgery are as follows: detachment and Kocher manoeuvre; release of the lower renal pole; clamping and sectioning of the renal artery; endocavitary ultrasound to locate the thrombus; placement of tourniquets in the vena cava below and above the renal veins and in the left renal vein; closure of the 3 tourniquets; opening of the vena cava; resection and extraction of the thrombus; suture of the vena cava; opening of the tourniquets; complete release of the kidney; bagging and extraction of the specimen. The surgery was performed without complications. The patient required a transfusion of 2 units of packed red blood cells and was discharged with modest renal failure (creatinine level of 1.60mg/dl). Radical nephrectomy with thrombectomy in the vena cava is a technique susceptible to severe complications and has, to date, been performed in few centres. We believe that the technique is reproducible and has clear advantages for our patients. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Shabib, Abdullah Bin; Alsayed, Fahad; Aldughaythir, Saad; Habeeb, Hanan; Al Tamimi, Sumayyah; Masuadi, Emad; Alzahrani, Mohsen; Alaklabi, Ali; Alotaibi, Azzam; Rajendram, Rajkumar; Almegren, Mosaad
2018-01-01
Inferior vena cava (IVC) filter is indicated in patients with acute venous thromboembolism (VTE) in whom therapeutic anticoagulation is contraindicated. While prophylactic insertion of an IVC filter may be considered for patients at high risk of VTE, there are significant differences between clinical guidelines on the role of IVC filters. These discrepancies have arisen predominantly because of the paucity of data on the efficacy and safety of IVC filters. We, therefore, evaluated the indications for filter insertion, the rate of filter retrieval and complications in patients who received IVC filters at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. A descriptive, retrospective review of electronic- and paper-based medical records was performed. Consecutive sampling was used to study all adult patients who received an IVC filter at KAMC between 2007 and 2016 and met the inclusion criteria. A total of 382 IVC filters were inserted. 113 patients (30%) had an acute VTE and a contraindication to anticoagulation while 53 patients (14%) received an IVC filter in the absence of VTE (i.e., prophylactic). Only 124 (32.5%) IVC filters were eventually retrieved. The most common reason for nonretrieval was the need for permanent filtration (155, 60%). Thrombotic complications developed in 72 (19%) patients; nine patients had fatal pulmonary embolism. The insertion of IVC filters in this cohort was associated with low retrieval rate and relatively high incidence of thrombotic complications. Follow-up of patients is required to detect IVC filter-related complications and to increase retrieval rate.
Günther Tulip inferior vena cava filter retrieval using a bidirectional loop-snare technique.
Ross, Jordan; Allison, Stephen; Vaidya, Sandeep; Monroe, Eric
2016-01-01
Many advanced techniques have been reported in the literature for difficult Günther Tulip filter removal. This report describes a bidirectional loop-snare technique in the setting of a fibrin scar formation around the filter leg anchors. The bidirectional loop-snare technique allows for maximal axial tension and alignment for stripping fibrin scar from the filter legs, a commonly encountered complication of prolonged dwell times.
A Comparison of Retrievability: Celect versus Option Filter.
Ryu, Robert K; Desai, Kush; Karp, Jennifer; Gupta, Ramona; Evans, Alan Emerson; Rajeswaran, Shankar; Salem, Riad; Lewandowski, Robert J
2015-06-01
To compare the retrievability of 2 potentially retrievable inferior vena cava filter devices. A retrospective, institutional review board-approved study of Celect (Cook, Inc, Bloomington, Indiana) and Option (Rex Medical, Conshohocken, Pennsylvania) filters was conducted over a 33-month period at a single institution. Fluoroscopy time, significant filter tilt, use of adjunctive retrieval technique, and strut perforation in the inferior vena cava were recorded on retrieval. Fisher exact test and Mann-Whitney-Wilcoxon test were used for comparison. There were 99 Celect and 86 Option filters deployed. After an average of 2.09 months (range, 0.3-7.6 mo) and 1.94 months (range, 0.47-9.13 mo), respectively, 59% (n = 58) of patients with Celect filters and 74.7% (n = 65) of patients with Option filters presented for filter retrieval. Retrieval failure rates were 3.4% for Celect filters versus 7.7% for Option filters (P = .45). Median fluoroscopy retrieval times were 4.25 minutes for Celect filters versus 6 minutes for Option filters (P = .006). Adjunctive retrieval techniques were used in 5.4% of Celect filter retrievals versus 18.3% of Option filter retrievals (P = .045). The incidence of significant tilting was 8.9% for Celect filters versus 16.7% for Option filters (P = .27). The incidence of strut perforation was 43% for Celect filters versus 0% for Option filters (P < .0001). Retrieval rates for the Celect and Option filters were not significantly different. However, retrieval of the Option filter required a significantly increased amount of fluoroscopy time compared with the Celect filter, and there was a significantly greater usage of adjunctive retrieval techniques for the Option filter. The Celect filter had a significantly higher rate of strut perforation. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Denali, Tulip, and Option Inferior Vena Cava Filter Retrieval: A Single Center Experience.
Ramaswamy, Raja S; Jun, Emily; van Beek, Darren; Mani, Naganathan; Salter, Amber; Kim, Seung K; Akinwande, Olaguoke
2018-04-01
To compare the technical success of filter retrieval in Denali, Tulip, and Option inferior vena cava filters. A retrospective analysis of Denali, Gunther Tulip, and Option IVC filters was conducted. Retrieval failure rates, fluoroscopy time, sedation time, use of advanced retrieval techniques, and filter-related complications that led to retrieval failure were recorded. There were 107 Denali, 43 Option, and 39 Tulip filters deployed and removed with average dwell times of 93.5, 86.0, and 131 days, respectively. Retrieval failure rates were 0.9% for Denali, 11.6% for Option, and 5.1% for Tulip filters (Denali vs. Option p = 0.018; Denali vs. Tulip p = 0.159; Tulip vs. Option p = 0.045). Median fluoroscopy time for filter retrieval was 3.2 min for the Denali filter, 6.75 min for the Option filter, and 4.95 min for the Tulip filter (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p = 0.67). Advanced retrieval techniques were used in 0.9% of Denali filters, 21.1% in Option filters, and 10.8% in Tulip filters (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p < 0.01). Filter retrieval failure rates were significantly higher for the Option filter when compared to both the Denali and Tulip filters. Retrieval of the Denali filter required significantly less amount of fluoroscopy time and use of advanced retrieval techniques when compared to both the Option and Tulip filters. The findings of this study indicate easier retrieval of the Denali and Tulip IVC filters when compared to the Option filter.
Stavropoulos, S William; Ge, Benjamin H; Mondschein, Jeffrey I; Shlansky-Goldberg, Richard D; Sudheendra, Deepak; Trerotola, Scott O
2015-06-01
To evaluate the use of endobronchial forceps to retrieve tip-embedded inferior vena cava (IVC) filters. This institutional review board-approved, HIPAA-compliant retrospective study included 114 patients who presented with tip-embedded IVC filters for removal from January 2005 to April 2014. The included patients consisted of 77 women and 37 men with a mean age of 43 years (range, 18-79 years). Filters were identified as tip embedded by using rotational venography. Rigid bronchoscopy forceps were used to dissect the tip or hook of the filter from the wall of the IVC. The filter was then removed through the sheath by using the endobronchial forceps. Statistical analysis entailed calculating percentages, ranges, and means. The endobronchial forceps technique was used to successfully retrieve 109 of 114 (96%) tip-embedded IVC filters on an intention-to-treat basis. Five failures occurred in four patients in whom the technique was attempted but failed and one patient in whom retrieval was not attempted. Filters were in place for a mean of 465 days (range, 31-2976 days). The filters in this study included 10 Recovery, 33 G2, eight G2X, 11 Eclipse, one OptEase, six Option, 13 Günther Tulip, one ALN, and 31 Celect filters. Three minor complications and one major complication occurred, with no permanent sequelae. The endobronchial forceps technique can be safely used to remove tip-embedded IVC filters. © RSNA, 2014.
The high-risk polytrauma patient and inferior vena cava filter use.
Berber, Onur; Vasireddy, Aswin; Nzeako, Obi; Tavakkolizadeh, Adel
2017-07-01
The aim of this study was to assess the impact on practice of vena cava filter insertion guidelines (Eastern Association for the Surgery of Trauma: practice management guidelines). The study was performed at a level 1 trauma centre with data from the 'Trauma Audit and Research Network' cross-referenced to hospital data. A total of 1138 specific 'high-risk' major trauma patients were identified over a 6-year period. The mean age was 46 years (18-102) and the male to female ratio was 3.3:1. The average Injury Severity Score was 23.6 (4-75). The overall DVT rate was 2.6% and the PE rate was 1.8%. A retrievable IVC filter was inserted in 42 cases (3.8%). The filter retrieval rate was 23.8% at a mean of 68.5days (4-107). Only one complication was reported of a breakthrough PE despite filter. Applying the EAST guidelines to this cohort would have suggested filter insertion in 279 (24.6%) cases. The kappa concordance value between observed practice and the 'EAST filter group' was 0.103 (poor). The PE rate in the 'EAST filter group' was 2.2% vs 1.6% in the 'no filter group' (p=0.601, no statistical difference) and the observed odds ratio was 0.814 (95% CI 0.413, 1.602). The EAST guidelines are useful but may be overestimating the need for filter insertion. Copyright © 2017 Elsevier Ltd. All rights reserved.
Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J
2018-05-01
Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P < .001), and force was distributed at significantly different rates (P < .001) during expansion. The largest radial expansion force at minimal caval diameter was seen in the Cook Platinum filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Smith, S Christian; Shanks, Candace; Guy, Gregory; Yang, Xiangyu; Dowell, Joshua D
2015-10-01
Retrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care. Seven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval. Of the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024). The retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates.
Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo
2016-01-01
PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713
Gotra, A; Doucet, C; Delli Fraine, P; Bessissow, A; Dey, C; Gallix, B; Boucher, L-M; Valenti, D
2018-05-14
To compare changes in inferior vena cava (IVC) filter positional parameters from insertion to removal and examine how they affect retrievability amongst various filter types. A total of 447 patients (260 men, 187 women) with a mean age of 55 years (range: 13-91 years) who underwent IVC filter retrieval between 2007-2014 were retrospectively included. Post-insertion and pre-retrieval angiographic studies were assessed for filter tilt, migration, strut wall penetration and retrieval outcomes. ANCOVA and multiple logistic regression models were used to analyze factors affecting retrieval success. Pairwise comparisons between filter types were performed. Of 488 IVC filter retrieval attempts, 94.1% were ultimately successful. The ALN filter had the highest mean absolute value of tilt (5.6 degrees), the Optease filter demonstrated the largest mean migration (-8.0mm) and the Bard G2 filter showed highest mean penetration (5.2mm). Dwell time of 0-90 days (OR, 11.1; P=0.01) or 90-180 days (OR, 2.6; P=0.02), net tilt of 10-15 degrees (OR 8.9; P=0.05), caudal migration of -10 to 0mm (OR, 3.46; P=0.03) and penetration less than 3mm (OR, 2.6; P=0.01) were positive predictors of successful retrievability. Higher odds of successful retrieval were obtained for the Bard G2X, Bard G2 and Cook Celect when compared to the ALN and Cordis Optease filters. Shorter dwell time, lower mean tilt, caudal migration and less caval wall penetration are positive predictors of successful IVC filter retrieval. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Indwelling and Retrieval Complications of Denali and Celect Infrarenal Vena Cava Filters.
Bos, Aaron S; Tullius, Thomas; Patel, Mikin; Leef, Jeffrey A; Navuluri, Rakesh; Lorenz, Jonathan M; Van Ha, Thuong G
2016-07-01
To compare indwelling and retrieval complications of Denali and Celect filters placed in the infrarenal inferior vena cava (IVC). A retrospective study was conducted over 2 years at a single institution in which 171 Denali and 162 Celect filters were placed in 333 patients with a mean age of 62.3 years ± 15.7 (161 men; 48.3%). Filter indications included venous thromboembolic disease (n = 320; 96.1%) and surgical prophylaxis (n = 13; 3.9%). A jugular approach was used to place 303 filters (91.0%). Computed tomography (CT) follow-up, complications, and retrieval data were obtained. Follow-up CT imaging was performed on 58 filters from each group with lower incidences of caval strut penetration (one vs 12) and filter tilt (one vs 15) in the Denali filter group (P = .002 and P < .001, respectively). There was no difference in incidences of breakthrough pulmonary embolism (P = .68). Retrieval attempts were performed on 43 Denali and 53 Celect filters with mean indwelling times at retrieval of 128.2 and 144.1 days, respectively (P = .40). Mean fluoroscopy time at retrieval was lower in the Denali group (3.1 min vs 6.0 min; P = .01). There were fewer cases of complex retrieval in the Denali group (n = 2 vs 10; P = .06). Tilt, fluoroscopy time, and air kerma were associated with complex retrieval (P = .04, P < .001, and P < .001, respectively). There was one Denali filter deployment complication that led to retrieval failure. This study suggests that Denali filters are associated with lower incidences of strut penetration and filter tilt as well as shorter fluoroscopy time at retrieval compared with Celect filters when placed in the infrarenal IVC. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Management of Fractured Inferior Vena Cava Filters: Outcomes by Fragment Location.
Trerotola, Scott O; Stavropoulos, S William
2017-09-01
Purpose To inform the management of fractured inferior vena cava filters on the basis of results from a tertiary referral center specializing in complex filter retrieval. Materials and Methods This study had institutional review board approval and was HIPAA compliant. Retrospective analysis of all patients with fractured filters and/or filter fragments evaluated for removal in a complex filter removal program was performed. Removal was attempted when fragments were intravascular or immediately extravascular by using primarily endobronchial forceps for caval fragments and snares for cardiac and pulmonary fragments. Data collected included success rate and complications of filter and fragment removal, symptoms relating to the filter or fragment, techniques used for removal, and follow-up of retained fragments. Results Sixty-five patients (12 men, 53 women) of a total of 222 patients referred for complex retrieval had fractured filters. Of these patients, two had undergone filter removal elsewhere and had retained fragments. All 63 filters were removed successfully with forceps (n = 61), a cone (n = 1), or a snare (n = 1). There were 116 separate filter fragments; removal was attempted for 78 fragments. Removal was successful for 63 (81%) of 78 fragments and varied by location. All extravascular fragments except one were retained. In all, 63 (54%) of 116 fragments were removed percutaneously, rendering 34 (54%) of 63 patients fragment free. Five minor (7.7% [five of 65]) and four major (6.2% [four of 65]) complications occurred. Conclusion Intravascular filter fragments can be removed safely with success rates that vary according to location. Because extravascular fragments are not readily accessible for removal, many patients are not rendered fragment free. © RSNA, 2017 Online supplemental material is available for this article.
Retrieval characteristics of the Bard Denali and Argon Option inferior vena cava filters.
Dowell, Joshua D; Semaan, Dominic; Makary, Mina S; Ryu, John; Khayat, Mamdouh; Pan, Xueliang
2017-11-01
The purpose of this study was to compare the retrieval characteristics of the Option Elite (Argon Medical, Plano, Tex) and Denali (Bard, Tempe, Ariz) retrievable inferior vena cava filters (IVCFs), two filters that share a similar conical design. A single-center, retrospective study reviewed all Option and Denali IVCF removals during a 36-month period. Attempted retrievals were classified as advanced if the routine "snare and sheath" technique was initially unsuccessful despite multiple attempts or an alternative endovascular maneuver or access site was used. Patient and filter characteristics were documented. In our study, 63 Option and 45 Denali IVCFs were retrieved, with an average dwell time of 128.73 and 99.3 days, respectively. Significantly higher median fluoroscopy times were experienced in retrieving the Option filter compared with the Denali filter (12.18 vs 6.85 minutes; P = .046). Use of adjunctive techniques was also higher in comparing the Option filter with the Denali filter (19.0% vs 8.7%; P = .079). No significant difference was noted between these groups in regard to gender, age, or history of malignant disease. Option IVCF retrieval procedures required significantly longer retrieval fluoroscopy time compared with Denali IVCFs. Although procedure time was not analyzed in this study, as a surrogate, the increased fluoroscopy time may also have an impact on procedural direct costs and throughput. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Temporary Inferior Vena Cava Filters: How Do We Move Forward?
Arous, Edward J; Messina, Louis M
2016-05-01
Despite their widespread use, the indications for the selective use of temporary inferior vena cava (IVC) filters remains uncertain with few trials supporting their use. Additionally, the risks of long-term temporary IVC filter insertion are being increasingly discussed amongst the mainstream media and through multiple class action lawsuits. Retrievable IVC filters were specifically designed to have a less secure implantation in order to facilitate retrieval. However, multiple reports have demonstrated significant filter-related complications, most commonly related to duration of implantation. Furthermore, the risk is not isolated to one manufacturer alone. The incidence of filter-related complications is linearly related to its duration of time on the market. Currently, the FDA recommends that IVC filters be removed within 25-54 days of their implantation. Unfortunately, little evidence exists to show that this recommendation is followed routinely. Recently, the PRESERVE Trial (NCT02381509) was initiated as a multicenter non-randomized open label study to determine the safety and effectiveness of commercially available IVC filters (both temporary and permanent) in individuals who require mechanical prophylaxis against pulmonary embolism. Until such evidence is developed, temporary IVC filters should be implanted based on best available evidence and routinely removed within the guidelines of the FDA of 25-54 days. A fair question at this point is whether the design features themselves that are required to manufacture a low profile removable IVC filter can achieve effective prophylaxis against pulmonary embolism at a low rate of short and long-term complications. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Deso, Steven E.; Idakoji, Ibrahim A.; Muelly, Michael C.; Kuo, William T.
2016-01-01
Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board–approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters. PMID:27247483
Deso, Steven E; Idakoji, Ibrahim A; Muelly, Michael C; Kuo, William T
2016-06-01
Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.
Klinken, Sven; Humphries, Charlotte; Ferguson, John
2017-10-01
To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = < 0.001). There was a non-significant reduction in IVC filter dwell time in the post-database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.
2D array transducers for real-time 3D ultrasound guidance of interventional devices
NASA Astrophysics Data System (ADS)
Light, Edward D.; Smith, Stephen W.
2009-02-01
We describe catheter ring arrays for real-time 3D ultrasound guidance of devices such as vascular grafts, heart valves and vena cava filters. We have constructed several prototypes operating at 5 MHz and consisting of 54 elements using the W.L. Gore & Associates, Inc. micro-miniature ribbon cables. We have recently constructed a new transducer using a braided wiring technology from Precision Interconnect. This transducer consists of 54 elements at 4.8 MHz with pitch of 0.20 mm and typical -6 dB bandwidth of 22%. In all cases, the transducer and wiring assembly were integrated with an 11 French catheter of a Cook Medical deployment device for vena cava filters. Preliminary in vivo and in vitro testing is ongoing including simultaneous 3D ultrasound and x-ray fluoroscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, S. Christian, E-mail: csmith@aemrc.arizona.edu; Shanks, Candace, E-mail: Candace.Shanks@osumc.edu; Guy, Gregory, E-mail: Gregory.Guy@osumc.edu
PurposeRetrievable inferior vena cava filters (IVCFs) are associated with long-term adverse events that have increased interest in improving filter retrieval rates. Determining the influential patient social and demographic factors affecting IVCF retrieval is important to personalize patient management strategies and attain optimal patient care.Materials and MethodsSeven-hundred and sixty-two patients were retrospectively studied who had a filter placed at our institution between January 2011 and November 2013. Age, gender, race, cancer history, distance to residence from retrieval institution, and insurance status were identified for each patient, and those receiving retrievable IVCFs were further evaluated for retrieval rate and time to retrieval.ResultsOfmore » the 762 filters placed, 133 were permanent filters. Of the 629 retrievable filters placed, 406 met the inclusion criteria and were eligible for retrieval. Results revealed patients with Medicare were less likely to have their filters retrieved (p = 0.031). Older age was also associated with a lower likelihood of retrieval (p < 0.001) as was living further from the medical center (p = 0.027). Patients who were white and had Medicare were more likely than similarly insured black patients to have their filters retrieved (p = 0.024).ConclusionsThe retrieval rate of IVCFs was most influenced by insurance status, distance from the medical center, and age. Race was statistically significant only when combined with insurance status. The results of this study suggest that these patient groups may need closer follow-up in order to obtain optimal IVCF retrieval rates.« less
A comparative CFD study of four inferior vena cava filters.
López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc
2018-03-30
Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of 4 different filter models in this realistic IVC geometry. We considered different blood flow rates in the range between V in =20 and V in =80 cm 3 /s, and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models, and we paid a special attention to the total drag force, F d , exerted by the blood flow on the filter surface. This force is the sum of 2 contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The F d force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest V in value investigated, the variation in F d among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, ie, if the patient with a filter implanted is treated with anticoagulant therapy. Copyright © 2018 John Wiley & Sons, Ltd.
In vitro evaluation of clot capture efficiency of an absorbable vena cava filter.
Dria, Stephen J; Eggers, Mitchell D
2016-10-01
The purpose of this study was to determine the in vitro clot capture efficiency (CCE) of an investigational absorbable inferior vena cava filter (IVCF) vs the Greenfield IVCF. Investigational absorbable and Greenfield filters were challenged with polyacrylamide clot surrogates ranging from 3 × 5 to 10 × 24 mm (diameter × length) in a flow loop simulating the venous system. Filters were challenged with clots until CCE standard error of 5% or less was achieved under binomial statistics. Pressure gradients across the filters were measured for the largest size clot, enabling calculation of forces on the filter. The in vitro CCE of the absorbable IVCF was statistically similar to that of the Greenfield filter for all clot sizes apart from the 3 × 10-mm clot, for which there was statistically significant difference between filter CCEs (absorbable filter, 59%; Greenfield filter, 31%; P = .0001). CCE ranged from an average 32% for the 3 × 5-mm clot to 100% for 7 × 10-mm and larger clots for the absorbable IVCF. Pressure gradient across the absorbable filter with 10 × 24-mm clot averaged 0.14 mm Hg, corresponding to a net force on the filter of 2.1 × 10(-3) N, compared with 0.39 mm Hg or 5.8 × 10(-3) N (P < .001) for the Greenfield filter. CCE of the absorbable filter was statistically similar to or an improvement on that of the Greenfield stainless steel filter for all clot sizes tested. CCE of the Greenfield filter in this study aligned with data from previous studies. Given the efficacy of the Greenfield filter in attenuating the risk of pulmonary embolism, the current study suggests that the absorbable filter may be a viable candidate for subsequent human testing. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin
2012-11-01
The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.
Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing
2013-06-04
To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.
Quintini, Cristiano; Miller, Charles M; Hashimoto, Koji; Philip, Ding; Uso, Teresa Diago; Aucejo, Federico; Kelly, Dympna; Winans, Charles; Eghtesad, Bijan; Vogt, David; Fung, John
2009-01-01
Venous outflow obstruction is a rare but potentially lethal complication after orthotopic liver transplantation (OLT) with the "piggyback" technique. Therapeutic options include angioplasty with or without stent placement, surgical reconstruction of the venous anastomosis, and retransplantation. Surgical options are technically very challenging and the outcomes discouraging. We describe here two cases of venous outflow obstruction in recipients of piggyback liver grafts, one involving both the vena cava and hepatic veins and the other affecting only hepatic vein outflow. Both patients were treated successfully with side-to-side cavo-cavostomy using an endovascular (endo-GIA) stapler. This novel technique is fast and effective in resolving the outflow obstruction. Copyright 2008 AASLD.
Robot-assisted laparoscopic reconstruction of retrocaval ureter: description and video of technique.
LeRoy, Timothy J; Thiel, David D; Igel, Todd C
2011-05-01
Ureteral obstruction secondary to retrocaval ureter is rarely reported in the urologic literature. Symptomatic retrocaval ureters usually present in the 3rd and 4th decade of life. Standard treatment involves ureteroureterostomy approximating the ureter anterior to the vena cava. We describe the initial presentation, imaging, port placement, and operative technique including video presentation of a robot-assisted laparoscopic repair of a retrocaval ureter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McConville, R. M., E-mail: richard_mcconville@hotmail.com; Kennedy, P. T.; Collins, A. J.
Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standardmore » anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lorenz, Jonathan M., E-mail: jlorenz@radiology.bsd.uchicago.edu; Beek, Darren van; Funaki, Brian
PurposeEvaluation of long-term outcomes of venoplasty and Gianturco stents to treat inferior vena cava (IVC) obstruction after liver transplantation.MethodsWe retrospectively analyzed records from 33 consecutive adult patients referred with the intent to treat suspected IVC obstruction after liver transplantation. Treatment was performed for occlusion or stenosis with a gradient exceeding 3 mmHg. The primary treatment was venoplasty and, if refractory, Gianturco stent placement. Recurrence prompted repeat venoplasty or stent placement.ResultsOf the 33 patients, 25 (aged 46.9 ± 12.2 years) required treatment at a mean of 2.3 years (14 days to 20.3 years) after transplantation. For technically successful cases, primary treatment was venoplasty alone (14) or with stentmore » placement (10). Technical success was 96 % (24 of 25) reflecting failure to cross one occlusion. Clinical success was 88 % (22 of 25) reflecting the technical failure and two that died of unrelated complications within 5 weeks. Cumulative primary patencies were 57.1 % at 6 months (n = 21) and 51.4 % at 1 (n = 10), 3 (n = 7), 5 (n = 6), and 7 (n = 5) years. Cumulative primary assisted patency was 95.2 % at 6 months (n = 21) and at 1 (n = 15), 3 (n = 9), 5 (n = 8), and 7 (n = 8) years. The 17 patients stented for refractory (n = 10) or recurrent (n = 7) stenosis had cumulative primary and primary assisted patencies of 86.0 and 100 %, respectively, from 6 months (n = 14) to 7 years (n = 3). No major complications occurred; one fractured stent was observed after 11.6 years.ConclusionFor IVC obstruction following liver transplantation, excellent long-term outcomes can be achieved by venoplasty and Gianturco stent placement.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scheffer, Hester J., E-mail: hj.scheffer@vumc.nl; Melenhorst, Marleen C. A. M., E-mail: m.melenhorst@vumc.nl; Vogel, Jantien A., E-mail: j.a.vogel@amc.uva.nl
Irreversible electroporation (IRE) is a novel image-guided ablation technique that is increasingly used to treat locally advanced pancreatic carcinoma (LAPC). We describe a 67-year-old male patient with a 5 cm stage III pancreatic tumor who was referred for IRE. Because the ventral approach for electrode placement was considered dangerous due to vicinity of the tumor to collateral vessels and duodenum, the dorsal approach was chosen. Under CT-guidance, six electrodes were advanced in the tumor, approaching paravertebrally alongside the aorta and inferior vena cava. Ablation was performed without complications. This case describes that when ventral electrode placement for pancreatic IRE is impaired,more » the dorsal approach could be considered alternatively.« less
Birkmeyer, Nancy J; Finks, Jonathan F; English, Wayne J; Carlin, Arthur M; Hawasli, Abdelkader A; Genaw, Jeffrey A; Wood, Michael H; Share, David A; Birkmeyer, John D
2013-04-01
The United States Food and Drug Administration recently issued a warning about adverse events in patients receiving inferior vena cava (IVC) filters. To assess relationships between IVC filter insertion and complications while controlling for differences in baseline patient characteristics and medical venous thromboembolism prophylaxis. Propensity-matched cohort study. The prospective, statewide, clinical registry of the Michigan Bariatric Surgery Collaborative. Bariatric surgery patients (n=35,477) from 32 hospitals during the years 2006 through 2012. Prophylactic IVC filter insertion. Outcomes included the occurrence of complications (pulmonary embolism, deep vein thrombosis, and overall combined rates of complications by severity) within 30 days of bariatric surgery. There were no significant differences in baseline characteristics among the 1,077 patients with IVC filters and in 1,077 matched control patients. Patients receiving IVC filters had higher rates of pulmonary embolism (0.84% vs 0.46%; odds ratio [OR], 2.0; 95% confidence interval [CI], 0.6-6.5; P=0.232), deep vein thrombosis (1.2% vs 0.37%; OR, 3.3; 95% CI, 1.1-10.1; P=0.039), venous thromboembolism (1.9% vs 0.74%; OR, 2.7; 95% CI, 1.1-6.3, P=0.027), serious complications (5.8% vs 3.8%; OR, 1.6; 95% CI, 1.0-2.4; P=0.031), permanently disabling complications (1.2% vs 0.37%; OR, 4.3; 95% CI, 1.2-15.6; P=0.028), and death (0.7% vs 0.09%; OR, 7.0; 95% CI, 0.9-57.3; P=0.068). Of the 7 deaths among patients with IVC filters, 4 were attributable to pulmonary embolism and 2 to IVC thrombosis/occlusion. We have identified no benefits and significant risks to the use of prophylactic IVC filters among bariatric surgery patients and believe that their use should be discouraged. Copyright © 2013 Society of Hospital Medicine.
Thromboembolic diseases and the use of vena cava filters.
De Silva, Samanthi
2017-04-01
Mr GW is a 77-year-old gentleman who is hoping to have a total knee replacement of his left knee. He underwent a knee replacement on the right in 2011 under spinal anaesthetic, where his postoperative period was complicated by a saddle pulmonary embolus (PE). Copyright the Association for Perioperative Practice.
Inferior Vena Cava Filters to Prevent Pulmonary Embolism: Systematic Review and Meta-Analysis.
Bikdeli, Behnood; Chatterjee, Saurav; Desai, Nihar R; Kirtane, Ajay J; Desai, Mayur M; Bracken, Michael B; Spencer, Frederick A; Monreal, Manuel; Goldhaber, Samuel Z; Krumholz, Harlan M
2017-09-26
Inferior vena cava (IVC) filters are widely used for prevention of pulmonary embolism (PE). However, uncertainty persists about their efficacy and safety. The authors conducted a systematic review and meta-analysis of the published reports on the efficacy and safety of IVC filters. The authors searched PubMed, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov through October 3, 2016, for randomized controlled trials (RCTs) or prospective controlled observational studies of IVC filters versus none in patients at risk of PE. Inverse variance fixed-effects models with odds ratio (OR) as the effect measure were used for primary analyses. Main outcomes included subsequent PE, PE-related mortality, all-cause mortality, and subsequent deep vein thrombosis (DVT). The authors' search retrieved 1,986 studies, of which 11 met criteria for inclusion (6 RCTs and 5 prospective observational studies). Quality of evidence for RCTs was low to moderate. Overall, patients receiving IVC filters had lower risk for subsequent PE (OR: 0.50; 95% confidence interval [CI]: 0.33 to 0.75); increased risk for DVT (OR: 1.70; 95% CI: 1.17 to 2.48); nonsignificantly lower PE-related mortality (OR: 0.51; 95% CI: 0.25 to 1.05); and no change in all-cause mortality (OR: 0.91; 95% CI: 0.70 to 1.19). Limiting the results to RCTs showed similar results. Findings were substantively similar across a wide range of sensitivity analyses. Very few prospective controlled studies, with limited quality of evidence, exist regarding the efficacy and safety of IVC filters. Overall, filters appear to reduce the risk of subsequent PE, increase the risk for DVT, and have no significant effect on overall mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Baumann, S; Becher, T; Giannakopoulos, K; Jabbour, C; Fastner, C; El-Battrawy, I; Ansari, U; Lossnitzer, D; Behnes, M; Alonso, A; Kirschning, T; Dissmann, R; Kueck, O; Stern, D; Michels, G; Borggrefe, M; Akin, I
2018-04-01
Pulmonary embolism (PE) is a frequently occurring complication in critically ill patients, and the simultaneous occurrence of PE and life-threatening bleeding is a therapeutic dilemma. Inferior vena cava filters (IVCF) may represent an important therapeutic alternative in these cases. The Angel® catheter (Bio2 Medical Inc., San Antonio, TX, USA) is a novel IVCF that provides temporary protection from PE and is implanted at bedside without fluoroscopy. The European Angel® Catheter Registry is an observational, multicenter study. In our German substudy, we investigated patients from three German hospitals and four intensive care units, who underwent Angel® catheter implantation between February 2016 and December 2016. A total of 23 critically ill patients (68 ± 9 years, 43% male) were included. The main indication for implantation was a high risk for or an established PE, combined with contraindications for prophylactic or therapeutic anticoagulation due to either an increased risk of bleeding (81%) or active bleeding (13%). The Angel® catheter was successfully inserted in all patients at bedside. No PE occurred in patients with an indwelling Angel® catheter. Clots with a diameter larger the 20 mm, indicating clot migration, were detected in 5% of the patients by cavography before filter retrieval. Filter retrieval was uneventful in all of our cases, while filter dislocation occurred in 3% of the patients. The German data from the multicenter European Angel® Catheter Registry show that the Angel® catheter is a safe and effective approach for critically ill patients with a high risk for the development of PE or an established PE, when an anticoagulation therapy is contraindicated.
Gohbara, Masaomi; Hayakawa, Keigo; Hayakawa, Azusa; Akazawa, Yusuke; Yamaguchi, Yukihiro; Furihata, Shuta; Kondo, Ai; Fukushima, Yusuke; Tomari, Sakie; Mitsuhashi, Takayuki; Endo, Tsutomu; Kimura, Kazuo
2018-03-01
Objective The admission glucose level is a predictor of mortality even in patients with acute pulmonary embolism (APE). However, whether or not the admission glucose level is associated with the severity of APE itself or the underlying disease of APE is unclear. Methods This study was a retrospective observational study. A pulmonary artery (PA) catheter was used to accurately evaluate the severity of APE. The percentage changes in the mean PA pressure (PAPm) upon placement and removal of the inferior vena cava filter (IVCF) were evaluated. We hypothesized that the admission glucose level was associated with the improvement in the PA pressure in patients with APE. Patients A total of consecutive 22 patients with submassive APE who underwent temporary or retrievable IVCF insertion on admission and repetitive PA catheter measurements upon placement and removal of IVCFs were enrolled. Results There was a significant positive correlation between the admission glucose levels and the percentage changes in the PAPm (r=0.543, p=0.009). A univariate linear regression analysis showed that the admission glucose level was the predictor of the percentage change in PAPm (β coefficient=0.169 per 1 mg/dL; 95% confidence interval, 0.047-0.291; p=0.009). A multivariate linear regression analysis with the forced inclusion model showed that the admission glucose level was the predictor of the percentage change in PAPm independent of diabetes mellitus, PAPm on admission, troponin positivity, and brain natriuretic peptide level (all p<0.05). Conclusion The admission glucose level was associated with the improvement in the PAPm in patients with submassive-type APE.
Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T
2018-06-01
To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.
Outcome and management of pacemaker-induced superior vena cava syndrome.
Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei
2014-11-01
We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.
Cunningham, Suzanne M; Ames, Marisa K; Rush, John E; Rozanski, Elizabeth A
2009-12-15
2 castrated male Labrador Retrievers (dogs 1 and 2) were evaluated 3 to 4 years after placement of a permanent pacemaker. Dog 1 was evaluated because of a large volume of chylous pleural effusion. Dog 2 was admitted for elective replacement of a pacemaker. Dog 1 had mild facial swelling and a rapidly recurring pleural effusion. Previously detected third-degree atrioventricular block had resolved. Cranial vena cava (CVC) syndrome secondary to pacemaker-induced thrombosis and stricture of the CVC was diagnosed on the basis of results of ultrasonography, computed tomography, and venous angiography. Dog 2 had persistent third-degree atrioventricular block. Intraluminal caval stricture and thrombosis were diagnosed at the time of pacemaker replacement. Radiographic evidence of pleural effusion consistent with CVC syndrome also was detected at that time. Dog 1 improved after treatment with unfractionated heparin and a local infusion of recombinant tissue-plasminogen activator. Balloon venoplasty was performed subsequently to relieve the persistent caval stricture. In dog 2, balloon dilatation of the caval stricture was necessary to allow for placement of a new pacing lead. Long-term anticoagulant treatment was initiated in both dogs. Long-term (> 6 months) resolution of clinical signs was achieved in both dogs. Thrombosis and stricture of the CVC are possible complications of a permanent pacemaker in dogs. Findings suggested that balloon venoplasty and anticoagulation administration with or without thrombolytic treatment can be effective in the treatment of dogs with pacemaker-induced CVC syndrome.
Kalinin, R E; Suchkov, I A; Pshennikov, A S; Agapov, A B
2016-01-01
To assess the effectiveness of anticoagulant therapy (ACT) for the treatment of patients with deep venous thrombosis (DVT) of the lower extremities. The study considered ultrasonic characteristics of lysis of the proximal part of thrombus: localization and nature of venous thrombosis, the length and diameter of the proximal floating part of the thrombus, and duration of the venous thrombosis. Depending on the ACT options patients were divided into 3 groups: Group 1 (18 patients) received rivaroxaban, group 2 (19 patients) received enoxaparin sodium with subsequent transition to warfarin, and 3 group (19 patietns) received enoxaparin sodium, followed by administration of rivaroxaban. Treatment with rivaroxaban was preferable over standard ACT with enoxaparin/warfarin with regards to the lysis of thrombus when duration of thrombosis did not exceed 10 days. In 10.5% of patients who received warfarin flotation of thrombi remained for 14 days; the length of the floating part of the thrombi did not exceed 3 cm. Such circumstances and inability to reach a therapeutic INR value required cava filter placement. Treatment with enoxaparin sodium followed by the administration of rivaroxaban was found to be the most efficient ACT regimen as there was no negative dynamics of ultrasound characteristics of lysis of thrombi at any duration of the disease.
Technical considerations in percutaneous hepatic perfusion--a multi-center experience.
Antoine, Radcliffe A
2011-03-01
Patients diagnosed with primary or metastatic liver cancer face a daunting future that is complicated by limited treatment options. Percutaneous hepatic perfusion is a novel approach to chemotherapy delivery that offers significant benefits over contemporary modalities. Percutaneous hepatic perfusion is a procedure in which a chemotherapeutic agent is administered at high doses via the hepatic artery where it perfuses the liver, is extracted and filtered using a veno-veno bypass circuit, a fenestrated multi-lumen double-balloon catheter, and two biocompatible hemoperfusion filters. Venous access is gained at the groin through the femoral vein after which the catheter is advanced and positioned in the inferior vena cava just below the right atrium.The catheter's proximal and distal balloons are inflated to occlude the inferior vena cava above and below the hepatic veins. The occlusion isolated the chemo-rich venous outflow of the liver from the systemic venous circulation. This maneuver also diverts venous blood returning to the heart from lower extremities of the azygos vein. Once the patient is on bypass, the agent is infused through the hepatic artery where it saturates the liver. The chemo-rich venous outflow is extracted through the double-balloon catheter by the bypass circuit. The blood is continuously filtered and cleared of the agent as it passes through the filters and returned to the patient through a catheter placed in the right internal jugular vein. A phase I study demonstrated efficacy with an overall radiographic response rate of 30% observed in treated patients. In 10 patients with ocular melanoma, a 50% overall response rate was observed, including two complete responses. The technique is minimally invasive and can be performed safely by a well-trained multi-disciplinary team. It offers significant benefits including multiple procedures without risks commonly associated with open abdominal surgery.
Technical Considerations in Percutaneous Hepatic Perfusion—A Multi-Center Experience
Antoine, Radcliffe A.
2011-01-01
Abstract: Patients diagnosed with primary or metastatic liver cancer face a daunting future that is complicated by limited treatment options. Percutaneous hepatic perfusion is a novel approach to chemotherapy delivery that offers significant benefits over contemporary modalities. Percutaneous hepatic perfusion is a procedure in which a chemotherapeutic agent is administered at high doses via the hepatic artery where it perfuses the liver, is extracted and filtered using a veno-veno bypass circuit, a fenestrated multi-lumen double-balloon catheter, and two biocompatible hemoperfusion filters. Venous access is gained at the groin through the femoral vein after which the catheter is advanced and positioned in the inferior vena cava just below the right atrium. The catheter’s proximal and distal balloons are inflated to occlude the inferior vena cava above and below the hepatic veins. The occlusion isolated the chemo-rich venous outflow of the liver from the systemic venous circulation. This maneuver also diverts venous blood returning to the heart from lower extremities of the azygos vein. Once the patient is on bypass, the agent is infused through the hepatic artery where it saturates the liver. The chemorich venous outflow is extracted through the double-balloon catheter by the bypass circuit. The blood is continuously filtered and cleared of the agent as it passes through the filters and returned to the patient through a catheter placed in the right internal jugular vein. A phase I study demonstrated efficacy with an overall radiographic response rate of 30% observed in treated patients. In 10 patients with ocular melanoma, a 50% overall response rate was observed, including two complete responses. The technique is minimally invasive and can be performed safely by a well-trained multi-disciplinary team. It offers significant benefits including multiple procedures without risks commonly associated with open abdominal surgery. PMID:21449232
Tapson, Victor F; Hazelton, Joshua P; Myers, John; Robertson, Claudia; Gilani, Ramyar; Dunn, Julie A; Bukur, Marko; Croce, Martin A; Peick, Ann; West, Sonlee; Lottenberg, Lawrence; Doucet, Jay; Miller, Preston R; Crookes, Bruce; Gandhi, Rajesh R; Croft, Chasen A; Manasia, Anthony; Hoey, Brian A; Lieberman, Howard; Guillamondegui, Oscar D; Novack, Victor; Piazza, Gregory; Goldhaber, Samuel Z
2017-09-01
To evaluate efficacy and safety of a novel device that combines an inferior vena cava (IVC) filter and central venous catheter (CVC) for prevention of pulmonary embolism (PE) in critically ill patients. In a multicenter, prospective, single-arm clinical trial, the device was inserted at the bedside without fluoroscopy and subsequently retrieved before transfer from the intensive care unit (ICU). The primary efficacy endpoint was freedom from clinically significant PE or fatal PE 72 hours after device removal or discharge, whichever occurred first. Secondary endpoints were incidence of acute proximal deep venous thrombosis (DVT), catheter-related thrombosis, catheter-related bloodstream infections, major bleeding events, and clinically significant thrombus (occupying > 25% of volume of filter) detected by cavography before retrieval. The device was placed in 163 critically ill patients with contraindications to anticoagulation; 151 (93%) were critically ill trauma patients, 129 (85%) had head or spine trauma, and 102 (79%) had intracranial bleeding. The primary efficacy endpoint was achieved for all 163 (100%) patients (95% confidence interval [CI], 97.8%-100%, P < .01). Diagnosis of new or worsening acute proximal DVT was time dependent with 11 (7%) occurring during the first 7 days. There were no (0%) catheter-related bloodstream infections. There were 5 (3.1%) major bleeding events. Significant thrombus in the IVC filter occurred in 14 (8.6%) patients. Prophylactic anticoagulation was not initiated for a mean of 5.5 days ± 4.3 after ICU admission. This novel device prevented clinically significant and fatal PE among critically ill trauma patients with low risk of complications. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Brown, Joshua; Talbert, Jeffery; Pennington, Ryan; Han, Qiong; Raissi, Driss
2018-01-01
Retrieval of inferior vena cava filters (IVCFs) is important to decrease the long-term risk of complications associated with indwelling devices. Our hospital experienced low retrieval rates and implemented a low-cost intervention and evaluation for quality improvement. The working hypothesis was that a simple, mailed letter intervention could increase retrieval rates by increasing patient and primary care provider knowledge of the need for retrieval. For all prospective patients who received a retrievable IVCF during the intervention period from January 1, 2014 to February 29, 2016, patients and their primary care providers were mailed letters encouraging contact with the clinic for evaluation of eligibility for retrieval. The main outcome was retrieval of the IVCF if clinically indicated with a secondary outcome of time-to-retrieval. A pre-intervention control group from October 1, 2011 to December 31, 2013 was used to evaluate the impact of the intervention. Competing risks, time-to-event analysis was used to compare the pre- and post-intervention period retrieval rates correcting for patients who died during follow-up. Between the pre- and post-intervention periods, crude retrieval rates increased from 4.4% to 8.1% with a 12-fold change at comparable time points. The time-to-retrieval in the pre-intervention period was a mean (SD) of 503 (207) days with a median (IQR) of 505 (301-742). In the post-intervention period, time-to-retrieval was a mean (SD) of 119 (83) days and with median (IQR) of 128 (38-164) days. This low-cost intervention significantly increased retrieval rates in a single clinic. However, retrieval rates remain low and can be further improved. Ongoing interventions, including improved patient follow-up and physician education, are being implemented to further improve retrieval and use of inferior vena cava filters. Implanting clinics should implement quality improvement initiatives to improve patient care and follow-up with IVCFs to ensure retrievals occur once clinically relevant in order to minimize long-term complications.
Helling, Thomas S; Kaswan, Sumesh; Miller, S Lee; Tretter, James F
2009-12-01
The use of permanent inferior vena cava filters (IVCFs) offers protection against pulmonary embolism (PE) but increases the long-term risk of deep vein thrombosis (DVT) and does not affect long-term mortality. The use of retrievable IVCFs in trauma patients offers the dual advantage of protection against PE during the risk period and the option of filter removal thus avoiding complications of DVT. Despite the safety of removal, it is likely that many of these retrievable filters are not removed. This was a retrospective, single-center, observational cohort study at a rural level I trauma center. We sought to investigate the number of patients and the circumstances under which retrievable IVCFs were placed and removed. During a 4-year period, 3,455 trauma patients were admitted and 125 patients had retrievable IVCFs placed (71 therapeutic and 54 prophylactic). The most common indications were traumatic brain and spinal cord injuries (66%). During in-hospital filter use, there were 36 new incidences (29%) of PE (1) and DVT (35). Nine patients died before removal. In 40 patients (32%), removal was attempted, and 32 (26%) retrievable IVCFs were successfully removed and in most patients (76%) within 180 days of insertion. Seventeen patients were transferred out of the area for extended care and lost to follow-up. In 55 patients, the filters were not removed. In 20 patients, the surgeon decided against removal. Thirty patients were transferred to extended care or rehabilitation within the community, but they did not return for removal. Thus, of 108/125 patients with follow-up, 76 patients (70%) did not have their IVCFs removed, and 50 patients did not have their IVCFs removed because of the choice of the surgeon, extended care, or rehabilitation. The use of retrievable IVCFs, when necessary, produced predictable protection against PE and DVT complications. Despite the opportunity for removal, most patients, in fact, did not have their filters removed, even when posthospital care could be tracked. The practices of the surgeon, the transfer to extended-care facilities, near or far, and the reluctance to remove long-standing IVCFs contributed to the high-retention rate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr
To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Juszkat, Robert, E-mail: radiologiamim@wp.p; Pukacki, Fryderyk; Zarzecka, Anna
We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The proceduremore » was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.« less
Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu
We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationshipmore » correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.« less
Nicolas, M; Malvé, M; Peña, E; Martínez, M A; Leask, R
2015-02-05
In this study, the trapping ability of the Günther Tulip and Celect inferior vena cava filters was evaluated. Thrombus capture rates of the filters were tested in vitro in horizontal position with thrombus diameters of 3 and 6mm and tube diameter of 19mm. The filters were tested in centered and tilted positions. Sets of 30 clots were injected into the model and the same process was repeated 20 times for each different condition simulated. Pressure drop experienced along the system was also measured and the percentage of clots captured was recorded. The Günther Tulip filter showed superiority in all cases, trapping almost 100% of 6mm clots both in an eccentric and tilted position and trapping 81.7% of the 3mm clots in a centered position and 69.3% in a maximum tilted position. The efficiency of all filters tested decreased as the size of the embolus decreased and as the filter was tilted. The injection of 6 clots raised the pressure drop to 4.1mmHg, which is a reasonable value that does not cause the obstruction of blood flow through the system. Copyright © 2014 Elsevier Ltd. All rights reserved.
Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?
Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette
2018-03-01
Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study shows that the filter appears to protect against PE in pregnancy but the numbers are small. Complications such as filter thrombosis and IVC penetration appear to be higher in pregnancy but this difference is not statistically significant. It is not possible to retrieve the device in one out of every four pregnant women. This has implications in terms of long term risk of lower limb thrombosis and post thrombotic syndrome. The decision to use an IVC filter in pregnancy needs careful consideration by a multidisciplinary team. The benefit and risk assessment should be individualised and clearly outlined to the patient. Copyright © 2017 Elsevier B.V. All rights reserved.
Kwon, Hyun-Jung; Jeong, Young-Il; Jun, In-Gu; Moon, Young-Jin; Lee, Yu-Mi
2018-01-01
Abstract Subclavian central venous catheterization is a common procedure for which misplacement of the central venous catheter (CVC) is a frequent complication that can potentially be fatal. The carina is located in the mid-zone of the superior vena cava (SVC) and is considered a reliable landmark for CVC placement in chest radiographs. The C-length, defined as the distance from the edge of the right transverse process of the first thoracic spine to the carina, can be measured in posteroanterior chest radiographs using a picture archiving and communication system. To evaluate the placement of the tip of the CVC in subclavian central venous catheterizations using the C-length, we reviewed the medical records and chest radiographs of 122 adult patients in whom CVC catheterization was performed (from January 2012 to December 2014) via the right subclavian vein using the C-length. The tips of all subclavian CVCs were placed in the SVC using the C-length. No subclavian CVC entered the right atrium. Tip placement was not affected by demographic characteristics such as age, sex, height, weight, and body mass index. The evidence indicates that the C-length on chest radiographs can be used to determine the available insertion length and place the right subclavian CVC tip into the SVC. PMID:29480861
Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.
Ozmen, Evrim; Algin, Oktay
2016-07-12
Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.
Denitrifying woodchip bioreactor and phosphorus filter pairing to minimize pollution swapping
USDA-ARS?s Scientific Manuscript database
Pairing denitrifying woodchip bioreactors and phosphorus-sorbing filters provides a unique, engineered approach for dual nutrient removal from waters impaired with both nitrogen (N) and phosphorus (P). This column study aimed to test placement of two P-filter media (acid mine drainage treatment resi...
Vena cava filter retrieval in therapeutically anticoagulated patients.
Schmelzer, Thomas M; Christmas, A Britton; Taylor, Dennis A; Heniford, B Todd; Sing, Ronald F
2008-12-01
Vena cava filters (VCFs) are indicated in patients with active venous thromboembolism and are a contraindication to therapeutic anticoagulation. When patients can be anticoagulated, VCFs can be removed; however, patients often have anticoagulation discontinued during the retrieval procedure, leaving them at risk for pulmonary embolism (PE). The authors evaluated their experience with retrieving VCFs in therapeutically anticoagulated patients. Data from a prospectively collected database of patients with VCFs placed between January 2005 and September 2007 were reviewed. The retrievals in therapeutically anticoagulated patients (international normalized ratio, 2.0-3.4) were performed using a strict protocol, including preretrieval and postretrieval cavograms. All retrievals were performed in the operating room, and patients were discharged home the same day and examined within 7 to 14 days. Descriptive statistics including means and counts were calculated. One hundred thirteen VCF removals occurred during the study period; 62 were attempted on anticoagulated patients (42 male and 20 female patients; mean age, 36.5 years). Thirty-five patients (56%) had VCFs placed for prophylaxis, 22 (35%) had deep venous thromboses or PEs but had contraindications to anticoagulation, and 5 (8%) were on anticoagulation, which was discontinued perioperatively for major surgical operations. The mean time the filters were in place was 153.7 days (range, 22-684 days). No extravasation was seen on postretrieval cavography. Eight of 62 removal attempts in anticoagulated patients were unsuccessful. One patient had a postoperative pneumothorax that was successfully managed without intervention. There were no operative bleeding complications, and no hematomas or contusions were seen at follow-up. The retrieval of VCFs in therapeutically anticoagulated patients can be performed without complication. Given the perioperative risk for PE, anticoagulation should not be discontinued for VCF retrieval.
Design-of-Experiments Approach to Improving Inferior Vena Cava Filter Retrieval Rates.
Makary, Mina S; Shah, Summit H; Warhadpande, Shantanu; Vargas, Ivan G; Sarbinoff, James; Dowell, Joshua D
2017-01-01
The association of retrievable inferior vena cava filters (IVCFs) with adverse events has led to increased interest in prompt retrieval, particularly in younger patients given the progressive nature of these complications over time. This study takes a design-of-experiments (DOE) approach to investigate methods to best improve filter retrieval rates, with a particular focus on younger (<60 years) patients. A DOE approach was executed in which combinations of variables were tested to best improve retrieval rates. The impact of a virtual IVCF clinic, primary care physician (PCP) letters, and discharge instructions was investigated. The decision for filter retrieval in group 1 was determined solely by the referring physician. Group 2 included those patients prospectively followed in an IVCF virtual clinic in which filter retrieval was coordinated by the interventional radiologist when clinically appropriate. In group 3, in addition to being followed through the IVCF clinic, each patient's PCP was faxed a follow-up letter, and information regarding IVCF retrieval was added to the patient's discharge instructions. A total of 10 IVCFs (8.4%) were retrieved among 119 retrievable IVCFs placed in group 1. Implementation of the IVCF clinic in group 2 significantly improved the retrieval rate to 25.3% (23 of 91 retrievable IVCFs placed, P < .05). The addition of discharge instructions and PCP letters to the virtual clinic (group 3) resulted in a retrieval rate of 33.3% (17 of 51). The retrieval rates demonstrated more pronounced improvement when examining only younger patients, with retrieval rates of 11.3% (7 of 62), 29.5% (13 of 44, P < .05), and 45.2% (14 of 31) for groups 1, 2, and 3, respectively. DOE methodology is not routinely executed in health care, but it is an effective approach to evaluating clinical practice behavior and patient quality measures. In this study, implementation of the combination of a virtual clinic, PCP letters, and discharge instructions improved retrieval rates compared with a virtual clinic alone. Quality improvement strategies such as these that augment patient and referring physician knowledge on interventional radiologic procedures may ultimately improve patient safety and personalized care. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Percutaneous Retrieval of Permanent Inferior Vena Cava Filters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu; Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Holly, Brian, E-mail: bholly3@jhmi.edu
PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filtersmore » was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanche, Alain F.; Pautas, Eric; Gouin, Isabelle
Purpose. To evaluate routine use of access sites in the arm for percutaneous caval filter placement (PCFP) in elderly patients. Neck arthritis, patient anxiety, access site thrombosis or fecal/urinary incontinence complicating jugular or femoral access may require alternative access sites in this population. Methods. Access via the right arm was chosen for PCFP (VenaTech LP). The indication for PCFP was deep vein thrombosis, a history of pulmonary embolism, and a contraindication to anticoagulant therapy. Ultrasound-guided puncture was performed after diameter measurement of the arm veins (O{sub AV}). The filter was inserted with standard imaging procedures. Procedural difficulty was graded andmore » compared with O{sub AV} and the angle from the arm vein to the superior vena cava ({alpha}{sub AV/SVC}). Results. Over 2 years, 16 patients (14 women, 2 men) with an average age of 90 years (range 79-97 years) were included in the study. The average O{sub AV} value of the basilic or brachial veins was 4.2 mm (range 3.0-5.1 mm). The minimal O{sub AV} for successful access was determined after the first 15 patients. No hematoma occurred at the puncture sites. The average {alpha}{sub AV/SVC} value was 62 deg. (range 29 deg. - 90 deg.). Arm access was possible in 12 of 16 patients (75%) with O{sub AV} {>=} 3.5 mm and {alpha}{sub AV/SVC} {>=} 29 deg. Every procedure via the arm was graded 'easy' by the operator, regardless of angulation values. Femoral access was used in one case due to the impossibility of traversing the heart (patient no. 2), and jugular access was used in 3 of 16 (19%) patients due to puncture failure (patient no. 4), small O{sub AV} (3 mm) (patient no. 6), and stenosis of the distal right subclavian vein (patient no.16), respectively. Conclusion. PCFP via the arm can be routinely accomplished in patients older than 75 years, provided O{sub AV} {>=} 3.5 mm, and {alpha}{sub AV/SVC} {>=} 200119 d.« less
Central Vein Dilatation Prior to Concomitant Port Implantation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian
2010-04-15
Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker andmore » occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.« less
Roy, Venkat; Simonetto, Andrea; Leus, Geert
2018-06-01
We propose a sensor placement method for spatio-temporal field estimation based on a kriged Kalman filter (KKF) using a network of static or mobile sensors. The developed framework dynamically designs the optimal constellation to place the sensors. We combine the estimation error (for the stationary as well as non-stationary component of the field) minimization problem with a sparsity-enforcing penalty to design the optimal sensor constellation in an economic manner. The developed sensor placement method can be directly used for a general class of covariance matrices (ill-conditioned or well-conditioned) modelling the spatial variability of the stationary component of the field, which acts as a correlated observation noise, while estimating the non-stationary component of the field. Finally, a KKF estimator is used to estimate the field using the measurements from the selected sensing locations. Numerical results are provided to exhibit the feasibility of the proposed dynamic sensor placement followed by the KKF estimation method.
Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.
Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John
2015-06-01
Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Le Blanche, Alain F., E-mail: le_blanche.alain@chu-amiens.fr; Ricco, Jean-Baptiste; Bonneau, Michel
Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately aftermore » deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter's stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter's stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.« less
Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Basheer, Mamoun Ahmad, E-mail: drbasheer30@yahoo.co; Hamilton, Mark; Holdaway, Chris
2008-07-15
AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump tomore » more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.« less
A Rare Case of Ileocecal Tuberculosis with Pulmonary Embolism and Deep Vein Thrombosis
Henry, Tan Chor Lip; Ho, Choon Aik; Mohamad, Yuzaidi
2017-01-01
Venous thromboembolism in tuberculosis is not a well recognised entity. It is a less frequently reported complication of severe pulmonary tuberculosis. It is exceedingly rare when it complicates extrapulmonary tuberculosis. Here, we present a case of 22-year-old young female with abdominal tuberculosis complicated with reverse ileocecal intussusception, deep vein thrombosis and pulmonary embolism. An emergency vena cava filter was inserted prior to a limited right hemicolectomy. In this article, we discuss the rare association of venous thromboembolism with ileocecal tuberculosis. PMID:28892968
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiefer, Ryan M., E-mail: rkiefer11@gmail.com; Pandey, Nirnimesh; Trerotola, Scott O.
PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tipmore » embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.« less
Totally laparoscopic caudate lobe resection: technical aspects and literature review.
Gringeri, Enrico; Boetto, Riccardo; Bassi, Domenico; D'Amico, Francesco E; Polacco, Marina; Romano, Maurizio; Barbieri, Stefania; Feltracco, Paolo; Spampinato, Marcello; Zanus, Giacomo; Cillo, Umberto
2014-12-01
The particular anatomic location of the hepatic caudate lobe between the hilar plate and inferior vena cava means that it is still considered unsuitable for laparoscopic measures and a difficult site even for conventional surgery. Here we describe the first case to be reported in the literature of caudate lobe resection for a single metastasis from breast adenocarcinoma that was completed using an exclusively laparoscopic procedure and a simplified scheme involving the placement of 4 trocars, without any need for conversion or the Pringle maneuver. The patient was 31 years old with a history of radical right mastectomy and chemotherapy. The patient's postoperative course was uneventful and she was discharged 4 days after the surgery. Twelve months on, she is currently alive and disease free.
Mumoli, Nicola; Barco, Stefano; Cei, Marco; Giorgi-Pierfranceschi, Matteo; Campanini, Mauro; Fontanella, Andrea; Ageno, Walter; Dentali, Francesco
2017-06-01
The decision concerning the introduction of primary and secondary prophylaxis of venous thromboembolism (VTE) in patients with solid brain neoplasms and brain metastases is often challenging due to the concomitant increased risk of intracranial hemorrhage and to limited evidence from available literature. A standardized questionnaire composed of nine multiple-choice questions regarding primary VTE prevention in non-surgical patients during high-risk conditions and VTE secondary prevention in patients with a solid brain neoplasm or cerebral metastases was sent via electronic mail to all the members (n = 2420) of the Italian Federation of the Internal Medicine Hospital Executives' Associations (FADOI) in June 2015. Three hundred and fifty two physicians (14.5%) returned it (participants' median age 51 years; females 46.9%). The majority of respondents prescribe primary thromboprophylaxis (usually with heparin) in non-surgical patients with solid brain neoplasms and brain metastases in concomitance with high-risk conditions. Full-dose anticoagulation with either low-molecular-weight heparin or fondaparinux is the preferred option for acute VTE (69.6%), while a reduced dose is chosen by 21.0% of physicians. The presence of a highly vascular brain neoplasm histotype mandates the prescription of a reduced-dose antithrombotic regimen in a minority of respondents. Vena cava filter placement is an option for the treatment of acute VTE in more than 6% of respondents. Anticoagulants are often prescribed for both VTE primary prevention and treatment. In conclusion, physicians' managements are partially in contrast to recent guidelines, reinforcing the need for educational programs and other studies in this setting.
Badjatia, Neeraj; O'Donnell, Joan; Baker, John R; Huang, David; Ayata, Cenk; Greer, David M; Carter, Bob S; Ogilvy, Christopher S; McDonald, Colin T
2004-01-01
Fever is common and difficult to control in patients with subarachnoid hemorrhage (SAH). We have previously shown an inverse relationship between fever and outcome in patients with SAH. This was a prospective, single-arm, feasibility trial in which nine patients with SAH underwent temperature management using an intravascular cooling catheter (ICC) to restore and maintain 24 hours of normothermia (36.5 degrees+/-0.2 degrees C). Enrollment occurred after development of a fever of at least 38.3 degrees C within 7 days of SAH that was refractory to acetaminophen treatment. The ICC was placed at the bedside through an introducer sheath via the femoral vein into the inferior vena cava (IVC). Portable X-ray confirmed placement. Normothermia was achieved in seven of the nine patients treated (78%); it was achieved in 100% of the patients with a 14F catheter (n=4) and in 60% of the patients with a 9F catheter (n=5). The two patients not reaching normothermia were not adequately treated for shivering. All other patients reached normothermia irrespective of intubation status. Overall, normothermia was well tolerated and not discontinued because of discomfort or adverse events. Two incidences of deep vein thrombosis were diagnosis by ultrasound that were not associated with clinical sequelae, and IVC filters were placed. No unanticipated adverse events occurred. We have demonstrated that fever can be safely and effectively controlled in patients with SAH for at least 24 hours using an ICC. Future studies are needed to assess the effect of such sustained therapy on outcome in patients with SAH.
Radiology-led Follow-up System for IVC Filters: Effects on Retrieval Rates and Times
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, L.; Taylor, J.; Munneke, G.
Purpose: Successful IVC filter retrieval rates fall with time. Serious complications have been reported following attempts to remove filters after 3-18 months. Failed retrieval may be associated with adverse clinical sequelae. This study explored whether retrieval rates are improved if interventional radiologists organize patient follow-up, rather than relying on the referring clinicians. Methods: Proactive follow-up of patients who undergo filter placement was implemented in May 2008. At the time of filter placement, a report was issued to the referring consultant notifying them of the advised timeframe for filter retrieval. Clinicians were contacted to arrange retrieval within 30 days. We comparedmore » this with our practice for the preceding year. Results: The numbers of filters inserted during the two time periods was similar, as were the numbers of retrieval attempts and the time scale at which they occurred. The rate of successful retrievals increased but not significantly. The major changes were better documentation of filter types and better clinical follow-up. After the change in practice, only one patient was lost to follow-up compared with six the preceding year. Conclusions: Although there was no significant improvement in retrieval rates, the proactive, radiology-led approach improved follow-up and documentation, ensuring that a clinical decision was made about how long the filter was required and whether retrieval should be attempted and ensuring that patients were not lost to follow-up.« less
Post traumatic inferior vena cava thrombosis: A case report and review of literature.
Chakroun, Amine; Nakhli, Mohamed Said; Kahloul, Mohamed; Harrathi, Mohamed Amine; Naija, Walid
2017-01-01
Post traumatic inferior vena cava (IVC) thrombosis is a rare and not well described entity with nonspecific clinical presentation. It remains a therapeutic challenge in traumatic context because of haemorrhagic risk due to anticoagulation. We report a case of IVC thrombosis in an 18 year-old man who presented with liver injury following a traffic crash. The thrombosis was incidentally diagnosed on admission by computed tomography. The patient was managed conservatively without anticoagulation initially considering the increasing haemorrhagic risk. IVC filter placing was not possible because of the unusual localization of the thrombus. Unfractionated heparin was started on the third day after CT scan control showing stability of hepatic lesions with occurrence of a pulmonary embolism. The final outcome was good. The management of post traumatic IVC thrombosis is not well described. Medical approach consists in conservative management with anticoagulation which requires the absence of active bleeding lesions. Surgical treatment is commonly based on thrombectomy under extracorporeal circulation. Interventional vascular techniques have become an important alternative approach for the treatment of many vessel lesions. Their main advantages are the relative ease and speed with which they can be performed. Post traumatic IVC thrombosis is a rare condition. Its management is not well defined. Early anticoagulation should be discussed on a case-by-case basis. Other alternatives such IVC filter or surgical thrombectomy may be used when the bleeding risk is increased. The most serious risk is pulmonary embolism. Outcome can be favorable even with non surgical approaches. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Combat Surgery: Medical Decision Trees for Treatment of Naval Combat Casualties
1991-02-01
inferior vena cava ? NO Is there a hole or tear of left atrium and/or pulmonary veins? NO l ** HEART INJURY ASSESSMENT MODULE T027 2...from holes in either superior or inferior vena cava ? YES NO See Pericardial Vena Cava Injury Module See Bleeding Into Pericardium Module T018...MODULE T018 1/1 Is blood coming from area of superior vena cava ? YES NO See Superior Vena Cava Wound
Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz
PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chibamore » needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.« less
Pan, Y; Zhao, J; Mei, J; Shao, M; Zhang, J; Wu, H
2016-12-01
The incidence of thrombus was investigated within retrievable filters placed in trauma patients with confirmed DVT at the time of retrieval and the optimal treatment for this clinical scenario was assessed. A technique called "filter retrieval with manual negative pressure aspiration thrombectomy" for management of filter thrombus was introduced and assessed. The retrievable filters referred for retrieval between January 2008 and December 2015 were retrospectively reviewed to determine the incidence of filter thrombus on a pre-retrieval cavogram. The clinical outcomes of different managements for thrombus within filters were recorded and analyzed. During the study 764 patients having Aegisy Filters implanted were referred for filter removal, from which 236 cases (134 male patients, mean age 50.2 years) of thrombus within the filter were observed on initial pre-retrieval IVC venogram 12-39 days after insertion (average 16.9 days). The incidence of infra-filter thrombus was 30.9%, and complete occlusion of the filter bearing IVC was seen in 2.4% (18) of cases. Retrieval was attempted in all 121 cases with small clots using a regular snare and sheath technique, and was successful in 120. A total of 116 cases with massive thrombus and IVC occlusion by thrombus were treated by CDT and/or the new retrieval technique. Overall, 213 cases (90.3%) of thrombus in the filter were removed successfully without PE. A small thrombus within the filter can be safely removed without additional management. CDT for reduction of the clot burden in filters was effective and safe. Filter retrieval with manual negative pressure aspiration thrombectomy seemed reasonable and valuable for management of massive thrombus within filters in some patients. Full assessment of the value and safety of this technique requires additional studies. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Heart Transplant in Patient With Isolated Left Superior Vena Cava by Atrial Appendage Rotation.
Reyes, Karl M; Gupta, Dipankar; Fricker, Frederick Jay; Cooke, Susan; Bleiweis, Mark S
2018-06-01
Orthotopic heart transplantation in patients with an isolated persistent left superior vena cava is extremely rare, and the anastomotic connection between a right-sided donor superior vena cava and left-sided recipient superior vena cava can be challenging to perform. We present a novel technique used in an infant female, using the left atrial appendage to extend the superior vena cava anastomosis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Using a new device to prevent pulmonary embolisms during pharmacomechanical thrombectomy.
Calleja, E; Ciampi, J J; Puche, J J; Lanciego, C
2018-04-20
We have used a new device to prevent pulmonary embolism during pharmacomechanical thrombectomy in a 25-year-old postpartum woman. The Angel® catheter (BiO2 Medical Inc., Golden, CO, USA) is a temporary device that combines the functions of a vena cava filter (VCF) with those of a triple-lumen central venous catheter. Normally, a VCF is implanted to prevent pulmonary embolism during pharmacomechanical thrombectomy. However, the complications associated with VCFs increase with time, not all of the filter can always be retrieved, and there can be iatrogenic effects both during implantation and retrieval. In our experience, this new device is much simpler to deploy and to retrieve. As is shown in this case, this temporary device can be an interesting alternative to a VCF for preventing pulmonary embolisms during pharmacomechanical thrombectomy. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Iramina, Hiraku; Hamaguchi, Takumi; Nakamura, Mitsuhiro; Mizowaki, Takashi; Kanno, Ikuo
2018-04-30
We evaluated two dual-energy cone-beam computed tomography (DE-CBCT) methodologies for a bench-top micro-CBCT system to reduce metal artifacts on reconstructed images. Two filter-based DE-CBCT methodologies were tested: (i) alternative spectral switching and (ii) simultaneous beam splitting. We employed filters of 0.6-mm-thick tin and 0.1-mm-thick tungsten to generate high- and low-energy spectra from 120 kVp X-rays, respectively. The spectral switching method was imitated by two half scans with different filters (pseudo-switching). Filters were placed and between the X-ray tube and a phantom ('1-u,' '2-u'), a phantom and a flat panel detector ('1-d,' '2-d'), and compared with (iii) two half scans at 80 and 140 kVp [pseudo-(80,140)]. For the splitting method, two half-width filters were aligned along a rotating axis. Projections were separated into halves and merged with corresponding areas of opposed projections after one full rotation. A solid 30-mm-diameter acrylic phantom and an acrylic phantom with four 5-mm-diameter titanium rods were used. DE images were generated by weighted summation of the high- and low-energy images. The blending factor was changed from 0 to +5 in increments of 0.01. Relative errors (REs) of the linear attenuation coefficients of the two phantoms and the contrast-to-noise ratios (CNRs) between the titanium and acrylic regions were compared. All methods showed zero REs except for the method (2-d). CNRs for pseudo-switching with upstream placement were 1.4-fold larger than CNRs for the pseudo-(80,140) method. CNRs for the downstream placements were small. It was concluded that the pseudo-switching method with upstream placement is appropriate for reducing metal artifacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu
Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less
Hosseinian, Leila; Levin, Matthew A; Fischer, Gregory W; Anyanwu, Anelechi C; Torregrossa, Gianluca; Evans, Adam S
2015-01-01
The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharifi, Mohsen, E-mail: seyedmohsensharifi@yahoo.com; Bay, Curt; Skrocki, Laura
Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receivemore » an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.« less
Salimi, Fereshte; Imani, Mohammad Reza; Ghasemi, Navab; Keshavarzian, Amir; Jazi, Amir Hosein Davarpanah
2013-01-01
Background: Long-term tunneled catheters are used for the hemodialysis or chemotherapy in many patients. Proper placement of the catheter tip could reduce early and late catheter related complications. Aim of the present study was to evaluate a new formula for proper placement of tunneled hemodialysis or infusion port device by using an external anatomic landmark. Materials and Methods: A total of 64 adult patients undergoing elective placement of tunneled Central Venous Catheter (CVC) requiring hemodialysis or chemotherapy were enrolled in this prospective study during 2011-2012 in the university hospital. The catheter length to be inserted in the right internal jugular vein (IJV) was calculated by adding two measurements (the shortest straight length between the insertion point of the needle and the suprasternal notch plus and half of sternal length). The catheter position was considered correct if the tip was positioned in the right atrium (RA) or Superior vena cava (SVC)-RA junction. Results: The patients were 55.28 ± 19.85 years of age, weighed 5.78 ± 16.62 kg and were 166.07 ± 10.27 cm tall. Catheters were inserted successfully in 88% of patients (n = 56). Catheter tip positions in the failures were SVC (n = 5), tricuspid valve (n = 2), and right ventricle (n = 1) in our patients. Conclusion: Long-term hemodialysis or port CVC could easily insert in the right IJV by using half of the sternal length as an external land marks among adult patients. PMID:24174941
Puerperal ovarian vein thrombosis: two case reports.
Angelini, Marta; Barillari, Giovanni; Londero, Ambrogio P; Bertozzi, Serena; Bernardi, Sergio; Petri, Roberto; Driul, Lorenza; Marchesoni, Diego
2013-02-01
Ovarian vein thrombosis (OVT) is an uncommon but potentially serious complication in the early postpartum. Two case studies seem to prove the point: Case 1 A 24-year-old woman was transferred to our hospital with the chief complaint of abdominal pain radiating to the right thigh, vomit, diarrhea, and a slight pyrexia (37.6 °C rectal). Five days earlier, she had a spontaneous vaginal delivery after labor induction. The woman appeared slightly distressed because of pain; vital signs were found to be normal and the CRP elevated (129.9 mg/L). Abdominal examination was remarkable for tenderness by palpation in the right lower quadrant with no rebound tenderness or guarding. Pelvic examination was remarkable for mild right adnexal tenderness. Abdominal-pelvic computer tomography with contrast medium revealed a 2.5-cm OVT having extended into the inferior vena cava for 14 cm with a slight peripheral edema. The patient was treated with nadroparin 0.6 cc (5700 IU) bid and warfarin 5 mg since the attainment of the therapeutic INR range. Case 2 A 31-year-old twin-pregnant woman had an emergency cesarean section at 35 gestational weeks because of hypertension complicated by increased liver enzymes, diuresis contraction, and continuous lower back pain bilaterally radiating to the groins. One day after delivery, CT scan that was performed because of onward anemia showed a pelvic, perihepatic, and perisplenic blood effusion, and a 1-cm right OVT extended to the inferior vena cava below renal veins for 28 mm. She underwent exploratory laparotomy and blood transfusion, and because of respiratory insufficiency she was transferred to a second level center with ICU facility, where she was placed under a suprarenal inferior vena cava filter, and AngioJet Rheolytic Thrombectomy for acute pulmonary embolism was performed.
Real time microcontroller implementation of an adaptive myoelectric filter.
Bagwell, P J; Chappell, P H
1995-03-01
This paper describes a real time digital adaptive filter for processing myoelectric signals. The filter time constant is automatically selected by the adaptation algorithm, giving a significant improvement over linear filters for estimating the muscle force and controlling a prosthetic device. Interference from mains sources often produces problems for myoelectric processing, and so 50 Hz and all harmonic frequencies are reduced by an averaging filter and differential process. This makes practical electrode placement and contact less critical and time consuming. An economic real time implementation is essential for a prosthetic controller, and this is achieved using an Intel 80C196KC microcontroller.
Zacharia, Brad E; Kahn, Sweena; Bander, Evan D; Cederquist, Gustav Y; Cope, William P; McLaughlin, Lily; Hijazi, Alexa; Reiner, Anne S; Laufer, Ilya; Bilsky, Mark
2017-08-01
OBJECTIVE The authors of this study aimed to identify the incidence of and risk factors for preoperative deep venous thrombosis (DVT) in patients undergoing surgical treatment for spinal metastases. METHODS Univariate analysis of patient age, sex, ethnicity, laboratory values, comorbidities, preoperative ambulatory status, histopathological classification, spinal level, and surgical details was performed. Factors significantly associated with DVT univariately were entered into a multivariate logistic regression model. RESULTS The authors identified 314 patients, of whom 232 (73.9%) were screened preoperatively for a DVT. Of those screened, 22 (9.48%) were diagnosed with a DVT. The screened patients were older (median 62 vs 55 years, p = 0.0008), but otherwise similar in baseline characteristics. Nonambulatory status, previous history of DVT, lower partial thromboplastin time, and lower hemoglobin level were statistically significant and independent factors associated with positive results of screening for a DVT. Results of screening were positive in only 6.4% of ambulatory patients in contrast to 24.4% of nonambulatory patients, yielding an odds ratio of 4.73 (95% CI 1.88-11.90). All of the patients who had positive screening results underwent preoperative placement of an inferior vena cava filter. CONCLUSIONS Patients requiring surgery for spinal metastases represent a population with unique risks for venous thromboembolism. This study showed a 9.48% incidence of DVT in patients screened preoperatively. The highest rates of preoperative DVT were identified in nonambulatory patients, who were found to have a 4-fold increase in the likelihood of harboring a DVT. Understanding the preoperative thrombotic status may provide an opportunity for early intervention and risk stratification in this critically ill population.
Congenital anomalies of the inferior vena cava revealed on CT in patients with deep vein thrombosis.
Gayer, G; Luboshitz, J; Hertz, M; Zissin, R; Thaler, M; Lubetsky, A; Bass, A; Korat, A; Apter, S
2003-03-01
We describe a possible relationship between inferior vena cava anomalies and extensive thrombosis of the inferior vena cava and the iliac and femoral veins. An anomaly of the inferior vena cava should be considered in young patients who present with deep vein thrombosis of the femoral and iliac veins. Coagulation abnormalities, frequently found in these patients, may be a contributory factor.
Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten
2011-02-01
Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.
The fenestrated Kawashima operation for single ventricle with interrupted inferior vena cava.
Hannan, Robert L; Rossi, Anthony F; Nykanen, David G; Lopez, Leo; Alonso, Francisco; White, Jeffrey A; Burke, Redmond P
2003-01-01
An 8-month-old boy with double outlet right ventricle with hypoplastic left ventricle, heterotaxy, left atrial isomerism, bilateral superior vena cavae without bridging vein, and interruption of the inferior vena cava with azygous continuation to the left superior cava underwent a bilateral bidirectional cavopulmonary anastomosis. A calibrated 3-mm connection between the right pulmonary artery and the common atrium was constructed with the proximal right superior vena cava to allow right to left shunting, analogous to a fenestration in a Fontan operation. We hypothesize that in small young patients undergoing the Kawashima operation a fenestration may improve postoperative hemodynamics.
Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.
Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo
2006-07-01
Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk
PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less
Interatrial septum pacing guided by three-dimensional intracardiac echocardiography.
Szili-Torok, Tamas; Kimman, Geert Jan P; Scholten, Marcoen F; Ligthart, Jurgen; Bruining, Nico; Theuns, Dominic A M J; Klootwijk, Peter J; Roelandt, Jos R T C; Jordaens, Luc J
2002-12-18
Currently, the interatrial septum (IAS) pacing site is indirectly selected by fluoroscopy and P-wave analysis. The aim of the present study was to develop a novel approach for IAS pacing using intracardiac echocardiography (ICE). Interatrial septum pacing may be beneficial for the prevention of paroxysmal atrial fibrillation. Cross-sectional images are acquired during a pull-back of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. Both atria are then reconstructed using three-dimensional (3D) imaging. Using an "en face" view of the IAS, the desired pacing site is selected. Following lead placement and electrical testing, another 3D reconstruction is performed to verify the final lead position. Twelve patients were included in this study. The IAS pacing was achieved in all patients including six suprafossal (SF) and six infrafossal (IF) lead locations all confirmed by 3D imaging. The mean duration times of atrial lead implantation and fluoroscopy were 70 +/- 48.9 min and 23.7 +/- 20.6 min, respectively. The IAS pacing resulted in a significant reduction of the P-wave duration as compared to sinus rhythm (98.9 +/- 19.3 ms vs. 141.3 +/- 8.6 ms; p < 0.002). The SF pacing showed a greater reduction of the P-wave duration than IF pacing (59.4 +/- 6.6 ms vs. 30.2 +/- 13.6 ms; p < 0.004). Three-dimensional ICE is a feasible tool for guiding IAS pacing.
2013-01-01
inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory
Denitrifying woodchip bioreactor and phosphorus filter pairing to minimize pollution swapping
Christianson, Laura E.; Lepine, Christine; Sibrell, Philip; Penn, Chad J.; Summerfelt, Steven T.
2017-01-01
Pairing denitrifying woodchip bioreactors and phosphorus-sorbing filters provides a unique, engineered approach for dual nutrient removal from waters impaired with both nitrogen (N) and phosphorus (P). This column study aimed to test placement of two P-filter media (acid mine drainage treatment residuals and steel slag) relative to a denitrifying system to maximize N and P removal and minimize pollution swapping under varying flow conditions (i.e., woodchip column hydraulic retention times (HRTs) of 7.2, 18, and 51 h; P-filter HRTs of 7.6–59 min). Woodchip denitrification columns were placed either upstream or downstream of P-filters filled with either medium. The configuration with woodchip denitrifying systems placed upstream of the P-filters generally provided optimized dissolved P removal efficiencies and removal rates. The P-filters placed upstream of the woodchip columns exhibited better P removal than downstream-placed P-filters only under overly long (i.e., N-limited) retention times when highly reduced effluent exited the woodchip bioreactors. The paired configurations using mine drainage residuals provided significantly greater P removal than the steel slag P-filters (e.g., 25–133 versus 8.8–48 g P removed m−3 filter media d−1, respectively), but there were no significant differences in N removal between treatments (removal rates: 8.0–18 g N removed m−3 woodchips d−1; N removal efficiencies: 18–95% across all HRTs). The range of HRTs tested here resulted in various undesirable pollution swapping by-products from the denitrifying bioreactors: nitrite production when nitrate removal was not complete and sulfate reduction, chemical oxygen demand production and decreased pH during overly long retention times. The downstream P-filter placement provided a polishing step for removal of chemical oxygen demand and nitrite.
Denitrifying woodchip bioreactor and phosphorus filter pairing to minimize pollution swapping.
Christianson, Laura E; Lepine, Christine; Sibrell, Philip L; Penn, Chad; Summerfelt, Steven T
2017-09-15
Pairing denitrifying woodchip bioreactors and phosphorus-sorbing filters provides a unique, engineered approach for dual nutrient removal from waters impaired with both nitrogen (N) and phosphorus (P). This column study aimed to test placement of two P-filter media (acid mine drainage treatment residuals and steel slag) relative to a denitrifying system to maximize N and P removal and minimize pollution swapping under varying flow conditions (i.e., woodchip column hydraulic retention times (HRTs) of 7.2, 18, and 51 h; P-filter HRTs of 7.6-59 min). Woodchip denitrification columns were placed either upstream or downstream of P-filters filled with either medium. The configuration with woodchip denitrifying systems placed upstream of the P-filters generally provided optimized dissolved P removal efficiencies and removal rates. The P-filters placed upstream of the woodchip columns exhibited better P removal than downstream-placed P-filters only under overly long (i.e., N-limited) retention times when highly reduced effluent exited the woodchip bioreactors. The paired configurations using mine drainage residuals provided significantly greater P removal than the steel slag P-filters (e.g., 25-133 versus 8.8-48 g P removed m -3 filter media d -1 , respectively), but there were no significant differences in N removal between treatments (removal rates: 8.0-18 g N removed m -3 woodchips d -1 ; N removal efficiencies: 18-95% across all HRTs). The range of HRTs tested here resulted in various undesirable pollution swapping by-products from the denitrifying bioreactors: nitrite production when nitrate removal was not complete and sulfate reduction, chemical oxygen demand production and decreased pH during overly long retention times. The downstream P-filter placement provided a polishing step for removal of chemical oxygen demand and nitrite. Copyright © 2017 The Conservation Fund. Published by Elsevier Ltd.. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.
2006-10-15
Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to themore » azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved.« less
Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco
2014-01-01
Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.
Selective Attachment of Nucleic Acid Molecules to Patterned Self-Assembled Surfaces.
1994-12-01
of different sequence is accomplished by placement of 8 liquid portions of nucleic acids at the desired position on the 9 filter. This method is...acids are selectively 24 bound from regions to which nucleic acids are excluded, other than 25 by placement of liquid aliquots (generally >1 Al) of...is typically non-covalent (i.e., ionic 16 bonding, or, less often, hydrogen bonding). Advantageously, non- 17 covalent bonding of nucleic acid
Robust failure detection filters. M.S. Thesis
NASA Technical Reports Server (NTRS)
Sanmartin, A. M.
1985-01-01
The robustness of detection filters applied to the detection of actuator failures on a free-free beam is analyzed. This analysis is based on computer simulation tests of the detection filters in the presence of different types of model mismatch, and on frequency response functions of the transfers corresponding to the model mismatch. The robustness of detection filters based on a model of the beam containing a large number of structural modes varied dramatically with the placement of some of the filter poles. The dynamics of these filters were very hard to analyze. The design of detection filters with a number of modes equal to the number of sensors was trivial. They can be configured to detect any number of actuator failure events. The dynamics of these filters were very easy to analyze and their robustness properties were much improved. A change of the output transformation allowed the filter to perform satisfactorily with realistic levels of model mismatch.
Meng, Max
2017-05-01
Level III inferior vena cava tumor thrombectomy for renal cancer is one of the most challenging open urologic surgeries. We present the initial series of completely intracorporeal robotic level III inferior vena cava tumor thrombectomy. Nine patients underwent robotic level III inferior vena cava thrombectomy and 7 patients underwent level II thrombectomy. The entire operation (high intrahepatic inferior vena cava control, caval exclusion, tumor thrombectomy, inferior vena cava repair, radical nephrectomy, and retroperitoneal lymphadenectomy) was performed exclusively robotically. To minimize the chances of intraoperative inferior vena cava thrombus embolization, an "inferior vena cava-first, kidney-last" robotic technique was developed. Data were accrued prospectively. All 16 robotic procedures were successful, without open conversion or mortality. For level III cases (9), median primary kidney (right 6, left 3) cancer size was 8.5cm (range: 5.3-10.8) and inferior vena cava thrombus length was 5.7cm (range: 4-7). Median operative time was 4.9 hours (range: 4.5-6.3), estimated blood loss was 375ml (range: 200-7,000), and hospital stay was 4.5 days. All surgical margins were negative. There were no intraoperative complications and 1 postoperative complication (Clavien 3b). At a median 7 months of follow-up (range: 1-18) all patients are alive. Compared to level II thrombi the level III cohort trended toward greater inferior vena cava thrombus length (3.3 vs 5.7cm), operative time (4.5 vs 4.9h) and blood loss (290 vs 375ml). With appropriate patient selection, surgical planning and robotic experience, completely intracorporeal robotic level III inferior vena cava thrombectomy is feasible and can be performed efficiently. Larger experience, longer follow-up and comparison with open surgery are needed to confirm these initial outcomes. Copyright © 2017. Published by Elsevier Inc.
Wu, Chun-Yu; Lin, Feng-Sheng; Wang, Yi-Chia; Chou, Wei-Han; Lin, Wen-Ying; Sun, Wei-Zen; Lin, Chih-Peng
2015-01-01
The role of ultrasound examination in detection of postprocedure complications from totally implantable venous access devices (TIVAD) placement is still uncertain. In a cohort of 665 cancer outpatients, we assessed a quick ultrasound examination protocol in early detection of mechanical complications of catheterization. Immediately after TIVAD placement, an ultrasound examination and chest radiography were performed to detect hemothorax, pneumothorax, and catheter malposition. The two methods were compared. Of the 668 catheters inserted, 628 were placed into axillary veins and 40 into internal jugular veins. The ultrasound examination took 2.5 ± 1.1 min. No hemothorax was detected, and neither pneumothorax nor catheter malposition was evident among the 40 internal jugular vein cannulations. Ultrasound and chest radiography examinations of the 628 axillary vein cannulations detected five and four instances of pneumothorax, respectively. Ultrasound detected all six catheter malpositions into the internal jugular vein. However, ultrasound failed to detect two out of three malpositions in the contralateral brachiocephalic vein and one kinking inside the superior vena cava. Without revision surgery, the operating time was 34.1 ± 15.6 min. With revision surgery, the operating time was shorter when ultrasound detected catheter malposition than when chest radiography was used (96.8 ± 12.9 vs. 188.8 ± 10.3 min, p < 0.001). Postprocedure ultrasound examination is a quick and sensitive method to detect TIVAD-related pneumothorax. It also precisely detects catheter malposition to internal jugular vein thus reduces time needed for revision surgery while chest radiography remains necessary to confirm catheter final position.
Wiles, H B
1991-01-01
The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125
Ecklonia cava promotes hair growth.
Bak, S S; Ahn, B N; Kim, J A; Shin, S H; Kim, J C; Kim, M K; Sung, Y K; Kim, S K
2013-12-01
Previous studies have reported the protective effects on skin elasticity of the edible marine seaweed Ecklonia cava, which acts through regulation of both antioxidative and anti-inflammatory responses. We evaluated the effect of E. cava and one of its components, dioxinodehydroeckol, on hair-shaft growth in cultured human hair follicles and on hair growth in mice. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to check cell viability of human dermal papilla cells (DPCs) and outer root sheath (ORS) cells after treatment with E. cava and its metabolite, dioxinodehydroeckol. Hair-shaft growth was measured using the in vitro hair-follicle organ-culture system, in the presence or absence of E. cava and dioxinodehydroeckol. Anagen induction activity was examined by topical application of E. cava to the dorsal skin of C57BL/6 mice. Insulin-like growth factor (IGF)-1 expression was measured by reverse transcriptase PCR and ELISA. The proliferation activity was found to be highest for the ethyl acetate-soluble fraction of E. cava (EAFE) in DPCs and in ORS cells. Treatment with EAFE resulted in elongation of the hair shaft in cultured human hair follicles, and promoted transition of the hair cycle from the telogen to the anagen phase in the dorsal skin of C57BL/6 mice. In addition, EAFE induced an increase in IGF-1 expression in DPCs. Dioxinodehydroeckol, a component of E. cava, induced elongation of the hair shaft, an increase in proliferation of DPCs and ORS cells, and an increase in expression of IGF-1 in DPCs. These results suggest that E. cava containing dioxinodehydroeckol promotes hair growth through stimulation of DPCs and ORS cells. © 2013 British Association of Dermatologists.
Ramman, Tarun Raina; Dutta, Nilanjan; Chowdhuri, Kuntal Roy; Agrawal, Sunny; Girotra, Sumir; Azad, Sushil; Radhakrishnan, Sitaraman; Iyer, Parvathi Unninayar; Iyer, Krishna Subramony
2018-01-01
Persistent left superior vena cava is a common congenital anomaly of the thoracic venous system. Left superior vena cava draining into left atrium is a malformation of sinus venosus and caval system. The anomaly may be a cause of unexplained hypoxia even in adults. It may give rise to various diagnostic and technical challenges during cardiac catheterization and open-heart surgery. It is often detected serendipitously during diagnostic workup. Isolated left superior vena cava opening into left atrium is very commonly associated with other congenital heart defects. But tetralogy of Fallot is very rarely associated with persistent left superior vena cava which drains into left atrium. We report four such cases who underwent surgical correction successfully.
IIR digital filter design for powerline noise cancellation of ECG signal using arduino platform
NASA Astrophysics Data System (ADS)
Rahmatillah, Akif; Ataulkarim
2017-05-01
Powerline noise has been one of significant noises of Electrocardiogram (ECG) signal measurement. This noise is characterized by a sinusoidal signal which has 50 Hz of noise and 0.3 mV of maximum amplitude. This paper describes the design of IIR Notch filter design to reject a 50 Hz power line noise. IIR filter coefficients were calculated using pole placement method with three variations of band stop cut off frequencies of (49-51)Hz, (48 - 52)Hz, and (47 - 53)Hz. The algorithm and coefficients of filter were embedded to Arduino DUE (ARM 32 bit microcontroller). IIR notch filter designed has been able to reject power line noise with average square of error value of 0.225 on (49-51) Hz filter design and 0.2831 on (48 - 52)Hz filter design.
Cross-sectional echocardiographic diagnosis of azygos continuation of the inferior vena cava.
Huhta, J C; Smallhorn, J F; Macartney, F J
1984-01-01
Azygos continuation of the inferior vena cava has importance for both the invasive diagnosis of congenital heart disease by catheterization and for surgical treatment. Cross-sectional echocardiography was used to examine 1,000 patients (1 day to 16 years, mean 3.3 years) who also had angiographic or surgical confirmation. Twenty-eight patients (3%) had azygos continuation (left 13, right 14, bilateral 1) and, in 26 patients, the hepatic portion of the inferior vena cava was absent. Azygos continuation was prospectively detected in all and was directly visualized in subcostal scans as a venous structure posterior to the aorta coursing behind the heart and not entering the inferior aspect of either atrium in 26/28 (93%). Azygos connection to the ipsilateral superior vena cava or atrium was correctly predicted in all. The inferior vena cava was visualized in all patients without azygos continuation, except one neonate with omphalocele. We conclude that cross-sectional echocardiography can accurately detect azygos continuation of the inferior vena cava and predict its side and connection.
Cross-sectional echocardiographic diagnosis of systemic venous return.
Huhta, J C; Smallhorn, J F; Macartney, F J; Anderson, R H; de Leval, M
1982-01-01
To determine the sensitivity and specificity of cross-sectional echocardiography in diagnosing anomalous systemic venous return we used the technique in 800 consecutive children with congenital heart disease and whom the diagnosis was ultimately confirmed by angiography. Cross-sectional echocardiography was performed without prior knowledge of the diagnosis in all but 11 patients, who were recalled because of a known abnormality of atrial situs. The sensitivity of cross-sectional echocardiographic detection of various structures was as follows: right superior vena cava 792/792 (100%); left superior vena cava 46/48 (96%); bilateral superior vena cava 38/40 (95%); bridging innominate vein with bilateral superior vena cava 13/18 (72%); connection of superior caval segment to heart (coronary sinus or either atrium) (100%); absence of suprarenal inferior vena cava 23/23 (100%); azygos continuation of the inferior vena cava 31/33 (91%); downstream connection of azygos continuation, once seen, 21/21 (100%); partial anomalous hepatic venous connection (one hepatic vein not connected to the inferior vena cava) 1/1 (100%); total anomalous hepatic venous connection (invariably associated with left isomerism) 23/23 (100%). The specificity of each above diagnoses was 100% except in one infant with exomphalos in whom absence of the suprarenal inferior vena cava was incorrectly diagnosed. Thus cross-sectional echocardiography is an extremely specific and highly sensitive method of recognizing anomalous systemic venous return. It is therefore of great value of planning both cardiac catheterisation and cannulation for open heart surgery. Images PMID:6751361
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
21 CFR 870.3260 - Vena cava clip.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...
1999-04-01
atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karuppasamy, Karunakaravel, E-mail: karuppk@ccf.org; Al-Natour, Mohammed, E-mail: mnatour85@msn.com; Gurajala, Ram Kishore, E-mail: gurajar@ccf.org
This report describes a stenting technique used to anatomically reconstruct superior vena cava (SVC) bifurcation in a patient with benign SVC syndrome. After recanalizing the SVC bifurcation, we exchanged two 0.035-in. wires for two 0.018-in. wires, deployed the SVC stent over these two wires (“train-track” technique), and stented each innominate vein over one wire. However, our decisions to recanalize both innominate veins, use the “buddy-wire” technique for SVC dilation, and dilate the SVC to 16 mm before stent deployment likely contributed to SVC tear, which was managed by resuscitation, SVC stent placement, and pericardial drainage. Here, we describe the steps ofmore » the train-track technique, which can be adopted to reconstruct other bifurcations; we also discuss the controversial aspects of this case.« less
A rare case of renal vein thrombosis due to urinary obstruction.
Jana, Tanima; Orlander, Philip R; Molony, Donald A
2015-08-01
Renal vein thrombosis (RVT) is an uncommon condition in adults and may be caused by endothelial damage, stasis, or hypercoagulable states. RVT is commonly identified in patients with nephrotic syndrome or malignancy. We present the case of a 57-yearold man with no past medical history who presented with a 1-month history of abdominal pain, dysuria, and hematuria. Initial laboratory studies were consistent with acute kidney injury (AKI). Imaging revealed bladder distension, enlargement of the prostate, bilateral hydronephrosis, and left renal vein thrombosis extending into the inferior vena cava. His renal failure and presenting symptoms resolved with placement of a Foley catheter and ureteral stent. The patient was discharged on anticoagulation. Here, we report a rare case of RVT that appears to have occurred as a consequence of obstructive uropathy causing massive bladder distention resulting in compression of the renal vein.
Anomalies of the systemic venous return: a review.
Mazzucco, A; Bortolotti, U; Stellin, G; Gallucci, V
1990-06-01
Congenital anomalies of the systemic venous connection to the heart represent a rather wide and heterogeneous group of malformations, whose physiological consequences may vary from nil to the most severe form of systemic arterial desaturation. The malformations may be summarized as follows: (1) Left superior vena cava connected to the coronary sinus, interrupted inferior vena cava and absent right superior vena cava that do not indicate surgical repair 'per se', but require some technical attention during open heart surgery performed for other anomalies; (2) Left superior vena cava connected to the left atrium, due to incorporation of the coronary sinus into the left atrial cavity, resulting in a right-to-left-shunt; (3) Right superior vena cava or inferior vena cava draining into the left atrium, both are extremely rare and require treatment for the ensuing right-to-left shunt; (4) Total anomalous systemic venous connection to the left atrium, usually combined with atrial isomerism and other very complex heart malformations; (5) Cor triatriatum dexter, which has been frequently diagnosed as an anomalous venous connection for its similar hemodynamic consequences. Such anomalies are reviewed with particular respect to their surgical implications.
Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis
2015-01-01
Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.
Mora, Guillermo
2014-03-01
Locating pacemaker electrodes can become complicated by congenital abnormalities such as persistent left superior vena cava (LSVC). To evaluate a technique for the implanting of ventricular electrode in patients with persistent LSVC. The study was carried out from June 2001 to June 2010 involving all patients who were admitted to the Hospital Universitario Mayor, Instituto de Corazon de Bogota and Hospital Universitario Clinica San Rafael (Bogota-Colombia) for implanting pacemakers or cardiac defibrillators. LSVC was diagnosed by fluoroscopic observation (anterior-posterior view) of the course of the stylet. Four steps were followed: 1) Move the electrode with a straight stylet to the right atrium. 2) Change the straight stylet by a conventional J stylet and push the electrode to the lateral or anterolateral wall of the right atrium. 3) Remove the guide 3-5 cm and 4) Push the electrode which crosses the tricuspid valve into the right ventricle and finally deploy the active fixation mechanism. A total of 1198 patients were admitted for pacemaker or cardiac defibrillator implant during the 9-year study period, 1114 received a left subclavian venous approach. There were 573 males and 541 females. Persistent LSVC was found in five patients (0.45%) Fluoroscopy time for implanting the ventricular electrode ranged from 60 to 250 seconds, 40 to 92 minutes being taken to complete the whole procedure. We present a simple and rapid technique for electrode placement in patients with LSVC using usual J guide and active fixation electrodes with high success.
Effects of septal pacing on P wave characteristics: the value of three-dimensional echocardiography.
Szili-Torok, Tamas; Bruining, Nico; Scholten, Marcoen; Kimman, Geert-Jan; Roelandt, Jos; Jordaens, Luc
2003-01-01
Interatrial septum (IAS) pacing has been proposed for the prevention of paroxysmal atrial fibrillation. IAS pacing is usually guided by fluoroscopy and P wave analysis. The authors have developed a new approach for IAS pacing using intracardiac echocardiography (ICE), and examined its effects on P wave characteristics. Cross-sectional images are acquired during pullback of the ICE transducer from the superior vena cava into the inferior vena cava by an electrocardiogram- and respiration-gated technique. The right atrium and IAS are then three-dimensionally reconstructed, and the desired pacing site is selected. After lead placement and electrical testing, another three-dimensional reconstruction is performed to verify the final lead position. The study included 14 patients. IAS pacing was achieved at seven suprafossal (SF) and seven infrafossal (IF) lead locations, all confirmed by three-dimensional imaging. IAS pacing resulted in a significant reduction of P wave duration as compared to sinus rhythm (99.7 +/- 18.7 vs 140.4 +/- 8.8 ms; P < 0.01). SF pacing was associated with a greater reduction of P wave duration than IF pacing (56.1 +/- 9.9 vs 30.2 +/- 13.6 ms; P < 0.01). P wave dispersion remained unchanged during septal pacing as compared to sinus rhythm (21.4 +/- 16.1 vs 13.5 +/- 13.9 ms; NS). Three-dimensional intracardiac echocardiography can be used to guide IAS pacing. SF pacing was associated with a greater decrease in P wave duration, suggesting that it is a preferable location to decrease interatrial conduction delay.
Unusual presentation of total anomalous systemic venous connection.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Pradhan, Priya M; Agarwal, Ravi
2017-07-01
A 9-year-old girl who presented with dyspnea on exertion was diagnosed with total anomalous systemic venous connection to the left atrium (both venae cavae), no left superior vena cava, and a moderate-sized atrial septal defect with severe pulmonary arterial hypertension and ectopic atrial rhythm. She underwent septation of the common atrium using autologous pericardium, thereby rerouting the superior vena cava, inferior vena cava, and coronary sinus to the right atrium. Her postoperative course was uneventful. This case is reported for its rarity of presentation with severe pulmonary arterial hypertension and ectopic atrial rhythm.
Vertebral artery origin stent placement with distal protection: technical and clinical results.
Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N
2006-05-01
To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.
Artifact Noise Removal Techniques on Seismocardiogram Using Two Tri-Axial Accelerometers
Luu, Loc; Dinh, Anh
2018-01-01
The aim of this study is on the investigation of motion noise removal techniques using two-accelerometer sensor system and various placements of the sensors on gentle movement and walking of the patients. A Wi-Fi based data acquisition system and a framework on Matlab are developed to collect and process data while the subjects are in motion. The tests include eight volunteers who have no record of heart disease. The walking and running data on the subjects are analyzed to find the minimal-noise bandwidth of the SCG signal. This bandwidth is used to design filters in the motion noise removal techniques and peak signal detection. There are two main techniques of combining signals from the two sensors to mitigate the motion artifact: analog processing and digital processing. The analog processing comprises analog circuits performing adding or subtracting functions and bandpass filter to remove artifact noises before entering the data acquisition system. The digital processing processes all the data using combinations of total acceleration and z-axis only acceleration. The two techniques are tested on three placements of accelerometer sensors including horizontal, vertical, and diagonal on gentle motion and walking. In general, the total acceleration and z-axis acceleration are the best techniques to deal with gentle motion on all sensor placements which improve average systolic signal-noise-ratio (SNR) around 2 times and average diastolic SNR around 3 times comparing to traditional methods using only one accelerometer. With walking motion, ADDER and z-axis acceleration are the best techniques on all placements of the sensors on the body which enhance about 7 times of average systolic SNR and about 11 times of average diastolic SNR comparing to only one accelerometer method. Among the sensor placements, the performance of horizontal placement of the sensors is outstanding comparing with other positions on all motions. PMID:29614821
Course of the inferior vena cava on lateral films exposed in different positions.
Lien, H H; Bakke, S J
1981-01-01
The distance from the posterior border of the inferior vena cava to the anterior vertebral margin was measured in 100 presumably normal patients in the supine position. Seventeen of these were also examined in the right and left lateral positions and the changes in course of the vena cava compared with the supine position.
Dai, Bingyang; Li, Lan; Li, Qiangqiang; Song, Xiaoxiao; Chen, Dongyang; Dai, Jin; Yao, Yao; Yan, Wenjin; Teng, Huajian; Yang, Fang; Xu, Zhihong; Jiang, Qing
2017-07-01
: L-Arginine (L-arg), widely known as a substrate for endogenous nitric oxide synthesis, can improve endothelial function associated with the vasculature, inhibit platelet aggregation, and alter the activity of vascular smooth muscle cells. P-selectin is a membrane component of the platelet alpha-granule and the endothelial cell-specific Wiebel-Palade body that plays a central role in mediating interactions between platelets and both leukocytes and the endothelium. The experiment was designed to evaluate the effect of novel microspheres with L-arg targeting P-selectin on the formation of deep vein thrombosis and repair of vascular wall in a rat model. Thrombosis of the inferior vena cava was induced by applying a piece of filter paper (5 mm × 10 mm) saturated with 10% FeCl3 solution for 5 min. Targeted microspheres with L-arg, targeted microspheres with water, and saline were injected into the tail veins of the rats after 30 min of applying the filter paper saturated with 10% FeCl3 solution. The dry weight and length of the thrombus isolated from the inferior vena cava were significantly decreased in the group with L-arg in microsphere after 24 h. No significant differences in prothrombin time, activated partial thromboplastin time, thrombin time, and fibrinogen among the groups were indicated. Images revealed that apoptosis in the vascular wall was less in the group injected with targeted microspheres with L-arg than in the other two groups at 1 and 8 d postsurgery. Meanwhile, cell proliferation was considerably excessive in the group injected with L-arg wrapped in targeted microspheres. Therefore, these novel microspheres could decrease the formation of thrombus in the early stages and in the subsequent periods of thrombosis. The microspheres can also enhance the vitality of impaired endothelial cells and reduce cell apoptosis.
Dai, Bingyang; Li, Lan; Li, Qiangqiang; Song, Xiaoxiao; Chen, Dongyang; Dai, Jin; Yao, Yao; Yan, Wenjin; Teng, Huajian; Yang, Fang; Xu, Zhihong; Jiang, Qing
2017-01-01
L-Arginine (L-arg), widely known as a substrate for endogenous nitric oxide synthesis, can improve endothelial function associated with the vasculature, inhibit platelet aggregation, and alter the activity of vascular smooth muscle cells. P-selectin is a membrane component of the platelet alpha-granule and the endothelial cell-specific Wiebel–Palade body that plays a central role in mediating interactions between platelets and both leukocytes and the endothelium. The experiment was designed to evaluate the effect of novel microspheres with L-arg targeting P-selectin on the formation of deep vein thrombosis and repair of vascular wall in a rat model. Thrombosis of the inferior vena cava was induced by applying a piece of filter paper (5 mm × 10 mm) saturated with 10% FeCl3 solution for 5 min. Targeted microspheres with L-arg, targeted microspheres with water, and saline were injected into the tail veins of the rats after 30 min of applying the filter paper saturated with 10% FeCl3 solution. The dry weight and length of the thrombus isolated from the inferior vena cava were significantly decreased in the group with L-arg in microsphere after 24 h. No significant differences in prothrombin time, activated partial thromboplastin time, thrombin time, and fibrinogen among the groups were indicated. Images revealed that apoptosis in the vascular wall was less in the group injected with targeted microspheres with L-arg than in the other two groups at 1 and 8 d postsurgery. Meanwhile, cell proliferation was considerably excessive in the group injected with L-arg wrapped in targeted microspheres. Therefore, these novel microspheres could decrease the formation of thrombus in the early stages and in the subsequent periods of thrombosis. The microspheres can also enhance the vitality of impaired endothelial cells and reduce cell apoptosis. PMID:28306627
Robotic inferior vena cava surgery.
Davila, Victor J; Velazco, Cristine S; Stone, William M; Fowl, Richard J; Abdul-Muhsin, Haidar M; Castle, Erik P; Money, Samuel R
2017-03-01
Inferior vena cava (IVC) surgery is uncommon and has traditionally been performed through open surgical approaches. Renal cell carcinoma with IVC extension generally requires vena cavotomy and reconstruction. Open removal of malpositioned IVC filters (IVCF) is occasionally required after endovascular retrieval attempts have failed. As our experience with robotic surgery has advanced, we have applied this technology to surgery of the IVC. We reviewed our institution's experience with robotic surgical procedures involving the IVC to determine its safety and efficacy. All patients undergoing robotic surgery that included cavotomy and repair from 2011 to 2014 were retrospectively reviewed. Data were obtained detailing preoperative demographics, operative details, and postoperative morbidity and mortality. Ten patients (6 men) underwent robotic vena caval procedures at our institution. Seven patients underwent robotic nephrectomy with removal of IVC tumor thrombus and retroperitoneal lymph node dissection. Three patients underwent robotic explantation of an IVCF after multiple endovascular attempts at removal had failed. The patients with renal cell carcinoma were a mean age of was 65.4 years (range, 55-74 years). Six patients had right-sided malignancy. All patients had T3b lesions at time of diagnosis. Mean tumor length extension into the IVC was 5 cm (range, 1-8 cm). All patients underwent robotic radical nephrectomy, with caval tumor thrombus removal and retroperitoneal lymph node dissection. The average operative time for patients undergoing surgery for renal cell carcinoma was 273 minutes (range, 137-382 minutes). Average intraoperative blood loss was 428 mL (range, 150-1200 mL). The patients with IVCF removal were a mean age of 33 years (range, 24-41 years). Average time from IVCF placement until robotic removal was 35.5 months (range, 4.3-57.3 months). Before robotic IVCF removal, a minimum of two endovascular retrievals were attempted. Average operative time for patients undergoing IVCF removal was 163 minutes (range, 131-202 minutes). Intraoperative blood loss averaged 250 mL (range, 150-350 mL). All procedures were completed robotically. The mean length of stay for all patients was 3.5 days (range, 1-8 days). All patients resumed ambulation on postoperative day 1. Nine patients resumed a regular diet on postoperative day 2. One patient with a renal tumor sustained a colon injury during initial adhesiolysis, before robotic radical nephrectomy, which was recognized at the initial operation and repaired robotically. Robotic radical nephrectomy and caval tumor removal were then completed. No blood transfusions were required intraoperatively, but three patients required blood transfusions postoperatively. Although robotic IVC surgery is uncommon, our initial limited experience demonstrates it is safe and efficacious. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oguzkurt, Levent, E-mail: loguzkurt@yahoo.com; Ozkan, Ugur; Demirturk, Orhan S.
Purpose: Our purpose was to report the outcome of endovascular treatment with manual aspiration thrombectomy as the first-line thromboablative method for phlegmasia cerulea dolens. Methods: Between October 2006 and May 2010, seven consecutive patients (5 women, 2 men; age range, 31-80 years) with the diagnosis of phlegmasia cerulea dolens secondary to acute iliofemoral deep venous thrombosis had endovascular treatment with manual aspiration thrombectomy. Catheter-directed thrombolysis and stent placement were used as adjunctive procedures. Phlegmasia was left-sided in five and right-sided in two patients. Results: All patients had associated great saphenous vein thrombosis in addition to iliofemoral deep vein thrombosis (DVT).more » Aspiration thrombectomy completely removed the thrombus from the popliteal vein to the inferior vena cava (IVC) in all cases. Three patients with May-Thurner syndrome had stent placement in the left common iliac vein. Two patients had early recurrences. Repeated aspiration thrombectomy was unsuccessful in one patient. There were no complications related to the procedure. One patient who had been successfully treated died of sepsis and another patient who had unsuccessful repeated interventions had below-the-knee amputation. Overall, the clinical success and survival rates of patients in this study were 86%. On follow-up, three patients with successful treatment were asymptomatic with no deep venous insufficiency. One of these patients died during the 4-month follow-up period. Two patients had mild ankle swelling with deep venous insufficiency. Conclusions: Manual aspiration thrombectomy with adjunctive use of catheter-directed thrombolysis and stent placement is an effective endovascular treatment method with high clinical success and survival rates for phlegmasia cerulean dolens.« less
Chiari, D; Bissolati, M; Gazzetta, P G; Guarneri, G; Tomanin, D; Maffi, P; Secchi, A; Rosati, R; Socci, C
2016-03-01
The gap between the number of diabetic patients on the waiting list for transplantation and the number of pancreas donors is growing and it is mandatory to extend criteria for donor eligibility. Several reports showed the feasibility of pancreas transplantation from pediatric donors with comparable outcomes to adult donors in terms of long-term β-cell function. However, there is no consensus about donor age and weight limits. We present two cases of pancreas transplantation alone (PTA) from very small pediatric donors: a 2-year-old female (weight 13 kg, height 88 cm) and a 6-year-old male (weight 29 kg, height 122 cm). We used a novel "cephalic placement" technique. The pancreas was placed upon the aortic carrefour with cephalic pole upward with 3 anchorage points: the left common iliac vein (or the inferior cava vein), the right common iliac artery, and an ileal loop. No postoperative thrombosis occurred and the patients gained insulin independence instantaneously. CT scan performed on postoperative day 3 showed regular organ perfusion in both cases. Graft volume and surface calculated by CT reconstruction were, respectively, 25 cc and 89 cm(2) in the first case, and 46.5 cc and 123 cm(2) in the second case. Postoperative mixed meal tolerance tests showed normal glycemic profile. Patients are actually insulin independent at 4 years and 8 months. Pancreases from very young pediatric donors are adequate to restore insulin independence after PTA in adult patients. The "cephalic placement" technique is feasible and effective using very small pancreases. Copyright © 2016 Elsevier Inc. All rights reserved.
Xiao, Liang; Huang, De-sheng; Shen, Jing; Tong, Jia-jie
2012-01-01
To determine whether the introducer curving technique is useful in decreasing the degree of tilting of transfemoral Tulip filters. The study sample group consisted of 108 patients with deep vein thrombosis who were enrolled and planned to undergo thrombolysis, and who accepted transfemoral Tulip filter insertion procedure. The patients were randomly divided into Group C and Group T. The introducer curving technique was Adopted in Group T. The post-implantation filter tilting angle (ACF) was measured in an anteroposterior projection. The retrieval hook adhering to the vascular wall was measured via tangential cavogram during retrieval. The overall average ACF was 5.8 ± 4.14 degrees. In Group C, the average ACF was 7.1 ± 4.52 degrees. In Group T, the average ACF was 4.4 ± 3.20 degrees. The groups displayed a statistically significant difference (t = 3.573, p = 0.001) in ACF. Additionally, the difference of ACF between the left and right approaches turned out to be statistically significant (7.1 ± 4.59 vs. 5.1 ± 3.82, t = 2.301, p = 0.023). The proportion of severe tilt (ACF ≥ 10°) in Group T was significantly lower than that in Group C (9.3% vs. 24.1%, χ(2) = 4.267, p = 0.039). Between the groups, the difference in the rate of the retrieval hook adhering to the vascular wall was also statistically significant (2.9% vs. 24.2%, χ(2) = 5.030, p = 0.025). The introducer curving technique appears to minimize the incidence and extent of transfemoral Tulip filter tilting.
Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.
Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F
2003-11-01
To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.
Lee, Jeong-Won; Seok, Jin Kyung; Boo, Yong Chool
2018-01-01
Airborne particulate matter can cause oxidative stress, inflammation, and premature skin aging. Marine plants such as Ecklonia cava Kjellman contain high amounts of polyphenolic antioxidants. The purpose of this study was to examine the antioxidative effects of E. cava extract in cultured keratinocytes exposed to airborne particulate matter with a diameter of <10 μ m (PM10). After the exposure of cultured HaCaT keratinocytes to PM10 in the absence and presence of E. cava extract and its constituents, cell viability and cellular lipid peroxidation were assessed. The effects of eckol and dieckol on cellular lipid peroxidation and cytokine expression were examined in human epidermal keratinocytes exposed to PM10. The total phenolic content of E. cava extract was the highest among the 50 marine plant extracts examined. The exposure of HaCaT cells to PM10 decreased cell viability and increased lipid peroxidation. The PM10-induced cellular lipid peroxidation was attenuated by E. cava extract and its ethyl acetate fraction. Dieckol more effectively attenuated cellular lipid peroxidation than eckol in both HaCaT cells and human epidermal keratinocytes. Dieckol and eckol attenuated the expression of inflammatory cytokines such as tumor necrosis factor- (TNF-) α , interleukin- (IL-) 1 β , IL-6, and IL-8 in human epidermal keratinocytes stimulated with PM10. This study suggested that the polyphenolic constituents of E. cava , such as dieckol, attenuated the oxidative and inflammatory reactions in skin cells exposed to airborne particulate matter.
Experimental Measurement of Small Scale Multirotor Flows
NASA Astrophysics Data System (ADS)
Connors, Jacob; Weiner, Joseph; Velarde, John-Michael; Glauser, Mark
2017-11-01
Work is being done to create a multirotor Unmanned Air Vehicle (UAV) based anemometer system that would allow for measurement of velocity and spectra in the atmospheric boundary layer. The flow from the UAV's rotors will impact such measurements and hence must be filtered. This study focuses on measuring the fluctuations of the velocity field in the flow both above and below various UAVs to determine first, the feasibility of the creation of the filter, and second, the optimal placement of the system on the body of the UAV. These measurements are taking place in both Syracuse University's subsonic wind tunnel and Skytop Turbulence Lab's Indoor Flow Lab. Constant Temperature Anemometry is being used to measure these velocity field fluctuations across a variety of UAVs with differing characteristics such as size, number of propellers, and rotor blade type. The data from these experiments is being used to define a method to estimate the filter band required to isolate noise from wake effects, and determine ideal sensor placement based on characteristics of the vehicle's design alone. The authors would like to thank The Center for Advanced Systems and Engineering (CASE) at Syracuse University for funding and supporting this work.
Guimaraes, Marcelo; Schonholz, Claudio; Hannegan, Christopher; Anderson, Michael Bret; Shi, June; Selby, Bayne
2012-08-01
To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
1995 Toxic Hazards Research Unit Annual Report.
1996-07-01
cabinet, the bile duct is cannulated using PE-10 tubing, the portal vein and inferior vena cava (above the diaphragm) are both cannulated with 16...homogenate in saline. Rats used to determine partition coefficients were euthanatized with C02. Blood was collected from the posterior vena cava ...sampled for histopathologic examination. Blood was sampled via the vena cava for clinical chemistry evaluations and whole livers were weighed at
Non-Invasive Methods of Cardiovascular Exploration in Aerospace Medicine.
1983-12-01
inferior vena cava Aorta right atrium filling chamber of right ventricle. Trunk of pulmonary art cry Posterior border: almost vertical AP lower arch left ... left ventricle. Inferior Vena cava infundihbulum L Upper border aortic arch Lower border superimposed borders of the RV LV right and left ventricles...iliac aneurisms is possible. isotopic phlebography is useful in the investigation of the permeability of the inferior vena cava
Baggett, Charles; Skeen, Shawn J.; Gantt, D. Scott; Trotter, Bradley R.; Birkemeier, Krista L.
2009-01-01
Isolated right superior vena cava drainage into the left atrium is an extremely rare cardiac anomaly, especially in the absence of other cardiac abnormalities. Only 28 of 5,127 reported consecutive congenital cardiac cases involved superior vena cava drainage into the left atrium, and all were associated with other cardiac anomalies. Of 19 reported cases of right superior vena cava drainage into the left atrium, most patients have been children who were experiencing mild hypoxemia and cyanosis. Herein, we describe the case of a 34-year-old woman who presented with asymptomatic hypoxemia in the peripartum period. She was diagnosed to have isolated drainage of the right superior vena cava into the left atrium. To the best of our knowledge, this is the 1st reported instance of such diagnosis by use of noninvasive imaging only, without cardiac catheterization. We also review the medical literature that pertains to our patient's anomaly. PMID:20069093
Wijesinghe, W A J P; Jeon, You-Jin
2012-03-01
Seaweeds are rich in vitamins, minerals, dietary fibres, proteins, polysaccharides and various functional polyphenols. Many researchers have focused on brown algae as a potential source of bioactive materials in the past few decades. Ecklonia cava is a brown seaweed that is abundant in the subtidal regions of Jeju Island in the Republic of Korea. This seaweed attracted extensive interest due to its multiple biological activities. E. cava has been identified as a potential producer of wide spectrum of natural substances such as carotenoids, fucoidans and phlorotannins showing different biological activities in vital industrial applications including pharmaceutical, nutraceutical, cosmeceutical and functional food. This review focuses on biological activities of the brown seaweed E. cava based on latest research results, including antioxidant, anticoagulative, antimicrobial, antihuman immunodeficiency virus, anti-inflammatory, immunomodulatory, antimutagenic, antitumour and anticancer effects. The facts summarized here may provide novel insights into the functions of E. cava and its derivatives and potentially enable their use as functional ingredients in potential industrial applications.
NASA Technical Reports Server (NTRS)
Schrier, R. W.; Humphreys, M. H.; Ufferman, R. C.
1971-01-01
Study of the differential characteristics of hepatic congestion and decreased cardiac output in terms of potential afferent stimuli in the antinatriuretic effect of acute thoracic inferior vena cava (TIVC) constriction. An attempt is made to see if the autonomic nervous system is involved in the antinatriuretic effect of acute TIVC or thoracic superior vena cava constriction.
Liu, Yunqi; Liu, Yanqiu; Xiong, Mai; Li, Hanzhao; Liu, Donghong; Zhang, Xi
2017-04-01
The left circumflex coronary artery associated with a fistula to superior vena cava is a rare entity. We describe a 7-year-old girl who presented with a cardiac murmur and was diagnosed with a coronary artery fistula between the left circumflex artery and superior vena cava by echocardiography. The surgical occlusion of the fistula was successful. © 2017, Wiley Periodicals, Inc.
Boutayeb, Alaae; Marmade, Lahcen; Bensouda, Adil; Moughil, Said
2012-01-01
The left superior vena cava is the most common congenital venous anomaly in the chest; however, its drainage into the left atrium is exceptional. The aim of the paper is to describe our novel technique to connect the left superior vena cava to the right cavities using the left atrial appendage, without cardiopulmonary bypass. PMID:22802356
Annual Progress Report Fiscal Year 1989
1989-09-30
thopaedics, Las Vegas, NV, February, 1989 clusion of the common iliac veins and inferior vena cava H following vaginal hysterectomy. A case report...The aorta and inferior vena cava will be transected and cannulated. Using techniques prescribed in the Microill product literature the aorta and both...via the inferior vena cava . At that point the animals will be refrigerated to allow overnight curing of the Microfil. As each animal has had only one
The Use of Hypertonic Solutions to Resuscitate Animals from Hypovolemic Shock.
1986-03-18
halothane/nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed...and on skeletal muscle inferior vena cava . Heart rate was recorded resting transmembrane potentials. These ef- and blood press.ure was monitored with...nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed through a
2011-03-01
protocol. Unfortunately for this grant project, this approval has come too late to acquire human subjects. Nonetheless, the MMI Lab will continue to...Gaussian filter ) of 10X clinical activity concentration (0.36 µCi/mL) images acquired on Day 1 with (LEFT) VAOR, (CENTER) TPB and (RIGHT) PROJSINE...trajectories. (ROW 3) Coronal and (ROW 4) transverse slices (smoothed with a Gaussian filter ) showing the placement and size of the VOI used to
Choi, Yohan; Hosseindoust, Abdolreza; Goel, Akshat; Lee, Suhyup; Jha, Pawan Kumar; Kwon, Ill Kyong; Chae, Byung-Jo
2017-01-01
In the present study, role of increasing levels of Ecklonia cava (seaweed) supplementation in diets was investigated on growth performance, coefficient of total tract apparent digestibility (CTTAD) of nutrients, serum immunoglobulins, cecal microflora and intestinal morphology of weanling pigs. A total of 200 weaned pigs (Landrace×Yorkshire×Duroc; initial body weight 7.08±0.15 kg) were randomly allotted to 4 treatments on the basis of body weight. There were 5 replicate pens in each treatment including 10 pigs of each. Treatments were divided by dietary Ecklonia cava supplementation levels (0%, 0.05%, 0.1%, or 0.15%) in growing-finishing diets. There were 2 diet formulation phases throughout the experiment. The pigs were offered the diets ad libitum for the entire period of experiment in meal form. The pigs fed with increasing dietary concentrations of Ecklonia cava had linear increase (p<0.05) in the overall average daily gain, however, there were no significant differences in gain to feed ratio, CTTAD of dry matter and crude protein at both phase I and phase II. Digestibility of gross energy was linearly improved (p<0.05) in phase II. At day 28, pigs fed Ecklonia cava had greater (linear, p<0.05) Lactobacillus spp., fewer Escherichia coli ( E. coli ) spp. (linear, p<0.05) and a tendency to have fewer cecal Clostridium spp. (p = 0.077). The total anaerobic bacteria were not affected with supplementation of Ecklonia cava in diets. Polynomial contrasts analysis revealed that villus height of the ileum exhibited a linear increase (p<0.05) in response with the increase in the level of dietary Ecklonia cava . However, villus height of duodenum and jejunum, crypt depth, villus height to crypt depth ratio of different segments of the intestine were not affected. The results suggest that Ecklonia cava had beneficial effects on the growth performance, cecal microflora, and intestinal morphology of weanling pigs.
Vena caval impalement: an unusual lawn mower injury in a child.
Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P
1998-06-01
Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.
Hakemi, Emad U; Alyousef, Tareq; Dang, Geetanjali; Hakmei, Jalal; Doukky, Rami
2015-03-01
Elevated cardiac troponin levels have been shown to be associated with adverse outcomes in patients with acute pulmonary embolism (PE). However, few data address the management implications of undetectable cardiac troponin I (cTnI) using a highly sensitive assay. We hypothesized that undetectable cTnI predicts very low in-hospital adverse event rates. In a retrospective cohort study, we classified patients with confirmed acute PE according to cTnI detectability into cTnI+ (≥ 0.012 ng/mL) and cTnI- (< 0.012 ng/mL) groups. The Pulmonary Embolism Severity Index (PESI) was used for clinical risk determination. The primary outcome was a composite of hard events defined as in-hospital death, CPR, or thrombolytic therapy. The secondary outcome was a composite of soft events defined as ICU admission or inferior vena cava filter placement. Among 298 consecutive patients with confirmed acute PE, 161 (55%) were cTnI+ and 137 (45%) cTnI-. No deaths occurred in the cTnI- group vs nine (6%) in the cTnI+ group (P = .004). No hard events were observed in the cTnI- group vs 15 (9%) in the cTnI+ group (P < .001). Soft events were observed at a lower rate in the cTnI- group (21[15%] vs 69 [43%], P < .001). Patients in the cTnI- group had a higher survival rate free of hard (P = .001) or soft (P < .001) events, irrespective of clinical risk. Furthermore, cTnI provided incremental prognostic value beyond clinical, ECG, and imaging data (P < .001). Highly sensitive cTnI assay provides an excellent prognostic negative predictive value; thus, it plays a role in identifying candidates for out-of-hospital treatment of acute PE.
Prevention of VTE in Orthopedic Surgery Patients
Francis, Charles W.; Johanson, Norman A.; Curley, Catherine; Dahl, Ola E.; Schulman, Sam; Ortel, Thomas L.; Pauker, Stephen G.; Colwell, Clifford W.
2012-01-01
Background: VTE is a serious, but decreasing complication following major orthopedic surgery. This guideline focuses on optimal prophylaxis to reduce postoperative pulmonary embolism and DVT. Methods: The methods of this guideline follow those described in Methodology for the Development of Antithrombotic Therapy and Prevention of Thrombosis Guidelines: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines in this supplement. Results: In patients undergoing major orthopedic surgery, we recommend the use of one of the following rather than no antithrombotic prophylaxis: low-molecular-weight heparin; fondaparinux; dabigatran, apixaban, rivaroxaban (total hip arthroplasty or total knee arthroplasty but not hip fracture surgery); low-dose unfractionated heparin; adjusted-dose vitamin K antagonist; aspirin (all Grade 1B); or an intermittent pneumatic compression device (IPCD) (Grade 1C) for a minimum of 10 to 14 days. We suggest the use of low-molecular-weight heparin in preference to the other agents we have recommended as alternatives (Grade 2C/2B), and in patients receiving pharmacologic prophylaxis, we suggest adding an IPCD during the hospital stay (Grade 2C). We suggest extending thromboprophylaxis for up to 35 days (Grade 2B). In patients at increased bleeding risk, we suggest an IPCD or no prophylaxis (Grade 2C). In patients who decline injections, we recommend using apixaban or dabigatran (all Grade 1B). We suggest against using inferior vena cava filter placement for primary prevention in patients with contraindications to both pharmacologic and mechanical thromboprophylaxis (Grade 2C). We recommend against Doppler (or duplex) ultrasonography screening before hospital discharge (Grade 1B). For patients with isolated lower-extremity injuries requiring leg immobilization, we suggest no thromboprophylaxis (Grade 2B). For patients undergoing knee arthroscopy without a history of VTE, we suggest no thromboprophylaxis (Grade 2B). Conclusions: Optimal strategies for thromboprophylaxis after major orthopedic surgery include pharmacologic and mechanical approaches. PMID:22315265
Günther Tulip and Celect IVC filters in multiple-trauma patients.
Rosenthal, David; Kochupura, Paul V; Wellons, Eric D; Burkett, Allison B; Methodius-Rayford, Walaya C
2009-08-01
To evaluate results with the retrievable Günther Tulip (GT) and Celect inferior vena cava filters (IVCFs) placed at the intensive care unit (ICU) bedside under "real-time" intravascular ultrasound (IVUS) guidance in multiple-trauma patients. Between December 2004 and December 2008, 187 multiple-trauma patients (109 men; mean age 44+/-2 years, range 17-71) with contraindications to low-dose anticoagulation therapy or sequential compression devices had Günther Tulip (n = 97) or Celect (n = 90) retrievable IVCFs placed under real-time IVUS guidance. Günther Tulip filters were inserted using a "double-puncture" technique. The Celect IVCFs were placed with a simplified single-puncture technique in which the filter introducer sheath was advanced until the radiopaque tip "covered" the IVUS image of the renal vein, indicating that the filter sheath was in position for filter deployment. The 2 filter groups were compared on the endpoints of technical implantation success, retrievability, prevention of PE, and procedure-related deep vein thrombosis (DVT). As verified by abdominal radiography, 93.1% (174/187) of IVCFs were placed without complications; 6 IVCFs (all GT; p = 0.03 versus Celect) were misplaced in the iliac vein but uneventfully retrieved and replaced in the IVC within 24 hours. Two insertion site femoral vein DVTs (both in the dual puncture group; p>0.2) and 5 groin hematomas occurred during follow-up. GT filters were in place a mean of 107 days and Celect 97 days. In this time, 2 pulmonary embolisms occurred (1 in each group; p>0.2). Of the 115 filters scheduled for retrieval (50 Günther Tulip, 65 Celect), 33 (23 Günther Tulip, 10 Celect) could not be retrieved (p = 0.0004). Vena cavography identified filter tilting (>20 degrees ) in 21 cases (15 GT, 6 Celect), while 12 filters (8 GT, 4 Celect) had extended indwell times (mean 187 days) and excessive tissue ingrowth covering the retrieval hook. Subjectively, the Celect filters were clinically "easier" to retrieve; they also had fewer cases of significant tilt (>20%) than the GT filters, but the difference was not statistically significant. GT and Celect IVCFs placed at the ICU bedside under IVUS guidance in multiple-trauma patients was simple, safe, and avoided transporting critically ill patients out of the ICU. Further investigation of the single sheath IVUS technique and the role of retrievable IVCFs in multi-trauma patients is warranted.
A Novel Approach to the Design of Passive Filters in Electric Grids
NASA Astrophysics Data System (ADS)
Filho da Costa Castro, José; Lima, Lucas Ramalho; Belchior, Fernando Nunes; Ribeiro, Paulo Fernando
2016-12-01
The design of shunt passive filters has been a topic of constant research since the 70's. Due to the lower cost, passive shunt filters are still considered a preferred option. This paper presents a novel approach for the placement and sizing of passive filters through ranking solutions based on the minimization of the total harmonic distortion (THDV) of the supply system rather than one specific bus, without neglecting the individual harmonic distortions. The developed method was implemented using Matlab/Simulink and applied to a test system. The results shown that is possible to minimize the total voltage harmonic distortion using a system approach during the filter selection. Additionally, since the method is mainly based on a heurist approach, it avoids the complexity associated with of use of advanced mathematical tools such as artificial intelligence techniques. The analyses contemplate a sinusoidal voltage utility and also the condition with background distortion utility.
Home interventions are effective at decreasing indoor nitrogen dioxide concentrations.
Paulin, L M; Diette, G B; Scott, M; McCormack, M C; Matsui, E C; Curtin-Brosnan, J; Williams, D L; Kidd-Taylor, A; Shea, M; Breysse, P N; Hansel, N N
2014-08-01
Nitrogen dioxide (NO2 ), a by-product of combustion produced by indoor gas appliances such as cooking stoves, is associated with respiratory symptoms in those with obstructive airways disease. We conducted a three-armed randomized trial to evaluate the efficacy of interventions aimed at reducing indoor NO2 concentrations in homes with unvented gas stoves: (i) replacement of existing gas stove with electric stove; (ii) installation of ventilation hood over existing gas stove; and (iii) placement of air purifiers with high-efficiency particulate air (HEPA) and carbon filters. Home inspection and NO2 monitoring were conducted at 1 week pre-intervention and at 1 week and 3 months post-intervention. Stove replacement resulted in a 51% and 42% decrease in median NO2 concentration at 3 months of follow-up in the kitchen and bedroom, respectively (P = 0.01, P = 0.01); air purifier placement resulted in an immediate decrease in median NO2 concentration in the kitchen (27%, P < 0.01) and bedroom (22%, P = 0.02), but at 3 months, a significant reduction was seen only in the kitchen (20%, P = 0.05). NO2 concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation. Replacing unvented gas stoves with electric stoves or placement of air purifiers with HEPA and carbon filters can decrease indoor NO2 concentrations in urban homes. Several combustion sources unique to the residential indoor environment, including gas stoves, produce nitrogen dioxide (NO2), and higher NO2 concentrations, are associated with worse respiratory morbidity in people with obstructive lung disease. A handful of studies have modified the indoor environment by replacing unvented gas heaters; this study, to our knowledge, is the first randomized study to target unvented gas stoves. The results of this study show that simple home interventions, including replacement of an unvented gas stove with an electric stove or placement of HEPA air purifiers with carbon filters, can significantly decrease indoor NO2 concentrations. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Richardson, James V.; Doty, Donald B.
1979-03-01
This report describes a rare case of isolated anomalous connection of the inferior vena cava to the left atrium. Patching of a surgically-created atrial septal defect and rerouting of caval drainage ino the right atrium effected a successful correction. This case brings to 18 the total number of reported cases in the literature in which the inferior vena cava was connected to the left atrium.
Clinical Investigation Program.
1979-10-01
It has been established by a series of dog experiments using the-e-e-ctromagnetic flow meter that the blood flow in the inferior vena cava between...by thermodilution. Hepatic vein blood flow could be estimated by subtraction of the blood flow in the vena cava at the level of the renal veins from...the vena cava blood flow at the level of the diaphragm. This should be liver blood flow. It should be possible to sample pure hepatic vein blood by
2001-10-25
a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV
Cardiac Ischemia Model for +Gz Using Miniature Swine and Baboons
2008-04-01
VAP was tunneled subcutaneously to an incision in the ventral neck and placed in the superior vena cava just craniad to the right atrium through...was passed transcutaneously to the su- perior vena cava from the arm or to the inferior vena cava from the lower leg, using fl uoroscopy. The...Five control swine were maintained on a standard swine diet. Also, nine male baboons had a constrictor placed around the left anterior descending
Structural and Functional Differences Between Porcine Aorta and Vena Cava.
Mattson, Jeffrey M; Zhang, Yanhang
2017-07-01
Elastin and collagen fibers are the major load-bearing extracellular matrix (ECM) constituents of the vascular wall. Arteries function differently than veins in the circulatory system; however as a result from several treatment options, veins are subjected to sudden elevated arterial pressure. It is thus important to recognize the fundamental structure and function differences between a vein and an artery. Our research compared the relationship between biaxial mechanical function and ECM structure of porcine thoracic aorta and inferior vena cava. Our study suggests that aorta contains slightly more elastin than collagen due to the cyclical extensibility, but vena cava contains almost four times more collagen than elastin to maintain integrity. Furthermore, multiphoton imaging of vena cava showed longitudinally oriented elastin and circumferentially oriented collagen that is recruited at supraphysiologic stress, but low levels of strain. However in aorta, elastin is distributed uniformly, and the primarily circumferentially oriented collagen is recruited at higher levels of strain than vena cava. These structural observations support the functional finding that vena cava is highly anisotropic with the longitude being more compliant and the circumference stiffening substantially at low levels of strain. Overall, our research demonstrates that fiber distributions and recruitment should be considered in addition to relative collagen and elastin contents. Also, the importance of accounting for the structural and functional differences between arteries and veins should be taken into account when considering disease treatment options.
Madjarov, Jeko M; Katz, Michael G; Madjarova, Sophia; Madzharov, Svetozar; Arko, Frank R; Miller, David W; Robicsek, Francis
2018-05-21
An anomalous muscle bundle crossing the right atrial cavity represents a pathological finding with unproved clinical significance. This congenital anomaly may be difficult to recognize via echocardiography and could be confused with other intra-cavitary lesions. We report a case of a 53-year-old female presented to the cardio-vascular service with acute superior vena cava syndrome and sub-massive pulmonary embolism. The patient underwent venography confirming superior vena cava stenosis. A ventilation/perfusion lung scan showed two sizable perfusion defects due to pulmonary embolism. MRI and echocardiography imaging demonstrated right atrium mass. Surgery was then carried out using standard cardiopulmonary bypass; right atrial muscle bundle was excised and superior vena cava reconstruction was performed. The patient was discharged uneventfully and remains symptom-free at two years follow-up. In cases of nonmalignant pathology of superior vena cava syndrome, appropriate studies should be conducted to exclude potential congenital abnormalities such as this anomalous muscle bundle in the right atrium. Open heart surgery is a viable treatment option in select cases. Published by Elsevier Inc.
Nath, Ranjit Kumar; Soni, Dheeraj Kumar
2015-12-01
A 22-year-old woman with severe mitral stenosis was referred to us for further evaluation and management. She was found to have severe mitral stenosis, severe tricuspid regurgitation with dilated right atrium and right ventricle with persistent left superior vena cava and hugely dilated coronary sinus. Valve was suitable for balloon mitral valvotomy. Cardiac catheterization showed interrupted inferior vena cava with azygos continuation to right atrium and large left superior vena cava draining to coronary sinus which was very much dilated. Right trans-jugular approach was tried for balloon mitral valvotomy, but was unsuccessful due to a very large right atrium and coronary sinus. Retrograde non trans-septal approach was used and balloon valvotomy was done successfully using a 24 mm × 40 mm TYSHAK balloon without any major complication. Reduction in the transmitral pressure gradient on cardiac catheterization data and transthoracic echocardiography confirmed successful procedure. Balloon mitral valvotomy can be done successfully in patients with the above unusual cardiac anatomy with no major procedural complications. © 2015 Wiley Periodicals, Inc.
Sabzi, Feridoun
2016-01-01
Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261
Tansel, T; Harmandar, B; Dayioglu, E; Onursal, E
2006-02-01
The majority of patients with partial anomalous drainage of pulmonary veins are asymptomatic during infancy and childhood. Patients with significant left-to-right shunt develop symptoms and benefit from early corrective surgery. Anomalous pulmonary veins draining into inferior vena cava is very rare and frequently encountered in association with scimitar syndrome. The purpose of this case report is to describe a non-scimitar patient with cor triatriatum who had anomalous dual drainage of right pulmonary veins into inferior vena cava/left atrium and anomalous connection of persistent left superior vena cava with a common pulmonary venous chamber. The patient underwent an operation with redirection of anomalous pulmonary venous drainage into left atrium and ligation of persistent left superior vena cava.
Mediastinal fibrosis and superior vena cava syndrome.
Novella Sánchez, Laura; Sanz Herrero, Francisco; Berraondo Fraile, Javier; Fernández Fabrellas, Estrella
2013-08-01
Superior vena cava syndrome is a clear sign for clinicians of infiltrative mediastinal involvement, usually caused by neoplasms in this location, and it is an indicator of poor prognosis. However, other diseases of benign origin can also cause these alterations. We present the case of a 34-year-old patient who debuted with symptoms of superior vena cava syndrome due to idiopathic mediastinal fibrosis, which presented a torpid evolution and few therapeutic alternatives. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.
[Superior vena cava syndrome--clinical aspects, etiology and case reports].
Serdarevic, M; Löhr, E; Reidemeister, J C
1984-06-01
The so-called superior-Cava Syndrome is caused by obstructions by centrally localized tumors by thrombosis or by inflammations of the mediastinum. In cases of tumorous infiltration a graft can be inserted. The different phenomena of thrombosis caused by nutritial catheters and pace makers are of clinical importance. Acute thrombosis of the brachio-cervical veins and the Vena Cava can be treated successfully by means of thrombolysis. Besides CT bilateral brachial phlebography communicates optimal information concerning localization of vascular obstruction and collateral circuits.
Home interventions are effective at decreasing indoor nitrogen dioxide concentrations
Paulin, L. M.; Diette, G. B.; Scott, M.; McCormack, M. C.; Matsui, E. C.; Curtin-Brosnan, J.; Williams, D. L.; Kidd-Taylor, A.; Shea, M.; Breysse, P. N.; Hansel, N. N.
2016-01-01
Nitrogen dioxide (NO2), a by-product of combustion produced by indoor gas appliances such as cooking stoves, is associated with respiratory symptoms in those with obstructive airways disease. We conducted a three-armed randomized trial to evaluate the efficacy of interventions aimed at reducing indoor NO2 concentrations in homes with unvented gas stoves: (i) replacement of existing gas stove with electric stove; (ii) installation of ventilation hood over existing gas stove; and (iii) placement of air purifiers with high-efficiency particulate air (HEPA) and carbon filters. Home inspection and NO2 monitoring were conducted at 1 week pre-intervention and at 1 week and 3 months post-intervention. Stove replacement resulted in a 51% and 42% decrease in median NO2 concentration at 3 months of follow-up in the kitchen and bedroom, respectively (P = 0.01, P = 0.01); air purifier placement resulted in an immediate decrease in median NO2 concentration in the kitchen (27%, P < 0.01) and bedroom (22%, P = 0.02), but at 3 months, a significant reduction was seen only in the kitchen (20%, P = 0.05). NO2 concentrations in the kitchen and bedroom did not significantly change following ventilation hood installation. Replacing unvented gas stoves with electric stoves or placement of air purifiers with HEPA and carbon filters can decrease indoor NO2 concentrations in urban homes. PMID:24329966
NASA Astrophysics Data System (ADS)
Roy, Soumen; Sengupta, Anand S.; Thakor, Nilay
2017-05-01
Astrophysical compact binary systems consisting of neutron stars and black holes are an important class of gravitational wave (GW) sources for advanced LIGO detectors. Accurate theoretical waveform models from the inspiral, merger, and ringdown phases of such systems are used to filter detector data under the template-based matched-filtering paradigm. An efficient grid over the parameter space at a fixed minimal match has a direct impact on the overall time taken by these searches. We present a new hybrid geometric-random template placement algorithm for signals described by parameters of two masses and one spin magnitude. Such template banks could potentially be used in GW searches from binary neutron stars and neutron star-black hole systems. The template placement is robust and is able to automatically accommodate curvature and boundary effects with no fine-tuning. We also compare these banks against vanilla stochastic template banks and show that while both are equally efficient in the fitting-factor sense, the bank sizes are ˜25 % larger in the stochastic method. Further, we show that the generation of the proposed hybrid banks can be sped up by nearly an order of magnitude over the stochastic bank. Generic issues related to optimal implementation are discussed in detail. These improvements are expected to directly reduce the computational cost of gravitational wave searches.
Optimal multi-type sensor placement for response and excitation reconstruction
NASA Astrophysics Data System (ADS)
Zhang, C. D.; Xu, Y. L.
2016-01-01
The need to perform dynamic response reconstruction always arises as the measurement of structural response is often limited to a few locations, especially for a large civil structure. Besides, it is usually very difficult, if not impossible, to measure external excitations under the operation condition of a structure. This study presents an algorithm for optimal placement of multi-type sensors, including strain gauges, displacement transducers and accelerometers, for the best reconstruction of responses of key structural components where there are no sensors installed and the best estimation of external excitations acting on the structure at the same time. The algorithm is developed in the framework of Kalman filter with unknown excitation, in which minimum-variance unbiased estimates of the generalized state of the structure and the external excitations are obtained by virtue of limited sensor measurements. The structural responses of key locations without sensors can then be reconstructed with the estimated generalized state and excitation. The asymptotic stability feature of the filter is utilized for optimal sensor placement. The number and spatial location of the multi-type sensors are determined by adding the optimal sensor which gains the maximal reduction of the estimation error of reconstructed responses. For the given mode number in response reconstruction and the given locations of external excitations, the optimal multi-sensor placement achieved by the proposed method is independent of the type and time evolution of external excitation. A simply-supported overhanging steel beam under multiple types of excitation is numerically studied to demonstrate the feasibility and superiority of the proposed method, and the experimental work is then carried out to testify the effectiveness of the proposed method.
Kovac, Jason R; Luke, Patrick P
2010-01-01
Excision of renal cell carcinoma (RCC) with corresponding vena cava thrombus is a technical challenge requiring open resection and vascular clamping. A 58 year old male with a right kidney tumor presented with a thrombus extending 1 cm into the vena cava. Using a hand-assisted transperitoneal approach through a 7 cm gel-port, the right kidney was dissected and the multiple vascular collaterals supplying the tumor were identified and isolated. The inferior vena cava was mobilized 4 cm cephalad and 4 cm caudal to the right renal vein. Lateral manual traction was applied to the right kidney allowing the tumor thrombus to be retracted into the renal vein, clear of the vena cava. After laparoscopic ultrasonographic confirmation of the location of the tip of the tumor thrombus, an articulating laparoscopic vascular stapler was used to staple the vena cava at the ostium of the right renal vein. This allowed removal of the tumor thrombus without the need for a Satinsky clamp. The surgery was completed in 243 minutes with no intra-operative complications. The entire kidney and tumor thrombus was removed with negative surgical margins. Estimated blood loss was 300 cc. We present a laparoscopic resection of a renal mass with associated level II thrombus using a hand-assisted approach. In patients with minimal caval involvement, our surgical approach presents an option to the traditional open resection of a renal mass.
GdnHCl-induced unfolding intermediate in the mitochondrial carbonic anhydrase VA.
Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Hassan, Md Imtaiyaz; Ahmad, Faizan
2016-10-01
Carbonic anhydrase VA (CAVA) is a mitochondrial enzyme belonging to the α-family of CAs, which is involved in several physiological processes including ureagenesis, lipogenesis, gluconeogenesis and neuronal transmission. Here, we have tried to understand the folding mechanism of CAVA using guanidine hydrochloride (GdnHCl)-induced denaturation at pH 8.0 and 25°C. The conformational stability was measured from the GdnHCl-induced denaturation study of CAVA monitored by circular dichroism (CD) and fluorescence measurements. On increasing the concentration of GdnHCl up to 5.0, a stable intermediate was observed between the concentrations 3.25M to 3.40M of the denaturant. However, CAVA gets completely denatured at 4.0M GdnHCl. The existence of a stable intermediate state was validated by 1-anilinonaphthalene-8-sulfonic acid (ANS binding) fluorescence and near-UV CD measurements. In silico studies were also performed to analyse the effect of GdnHCl on the structure and stability of CAVA under explicit conditions. Molecular dynamics simulations for 40ns were carried out and a well-defined correlation was established for both in vitro and in silico studies. Copyright © 2016 Elsevier B.V. All rights reserved.
Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines.
Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel
2016-10-27
Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na⁺, K⁺, Ca 2+ , Cl - , and CO₃ 2- , one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.
Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines
Giménez-Gómez, Pablo; Escudé-Pujol, Roger; Capdevila, Fina; Puig-Pujol, Anna; Jiménez-Jorquera, Cecilia; Gutiérrez-Capitán, Manuel
2016-01-01
Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions. PMID:27801796
Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna
2014-01-01
Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.
[Syndrome of vena cava obstruction in oncology].
Kohútek, F; Litvin, I; Tamášová, M; Bystrický, B
2013-01-01
Superior vena cava syndrome (SVCO) is caused by compression of superior vena cava and restriction of blood flow to the heart. The most common underlying condition in cancer patients is lung cancer or other malignancy expanding in the upper mediastinum. SVCO belongs to oncological emergencies and requires a prompt dia-gnostic work up and treatment. A 79year old man with a history of right sided stage IIIB nonsmall cell lung cancer, after two cycles of chemotherapy, was admitted to hospital with clinical signs of SVCO. The initial radiotherapy brought no relief of symptoms and due to deterioration of patients status during the treatment we proceeded to self expanding caval stent insertion. This was followed by immediate resolution of SVCO symptoms. In the second case we describe a 56year old female with a newly dia-gnosed diffuse large B cell lymphoma who presented with SVCO symptoms when referred to our outpatient chemotherapy department. She had no history of previous treatment and she complained of a rapid face and eyelid edema and intractable cough in the last two days. CT scan revealed mediastinal mass compressing the superior vena cava. Urgent antilymphoma chemotherapy (RCHOP schedule) was commenced and yielded quick resolution of her symp-toms. Superior vena cava syndrome is a medical emergency in oncological patients usually caused by external compression of cava by lung cancer, lymphoma, other tumors, less frequently, from a thrombosis of indwelling central venous catheter. Multidiscip-linary cooperation among radiation and medical oncologists and interventional radiologists is needed in order to provide an early treatment without an undue delay.
Very long stripe-filters for a multispectral detector
NASA Astrophysics Data System (ADS)
Laubier, D.; Mercier Ythier, Renaud
2017-11-01
In order to simplify instrument design, a new linear area CCD sensor has been developed under CNES responsibility. This detector has four lines 6000 13-μm square pixels long with four stripe filters, one in front of each of them. The detector itself was manufactured and mounted by ATMEL, and the filters were made by SAGEM/REOSC. Assembly was done in two ways, one by ATMEL, the other by SESO. CNES was responsible for the overall design and mechanical/optical interfaces. This paper reports the optical part of this work, including filters placement strategy and line spacing. It will be shown how these two features are closely linked to straylight performance. First, a trade-off study was conducted between several concepts: the results of this study will be presented, as well as the filter design and manufacturing results. They show good transmission and excellent rejection. Final performance of the complete prototypes has been measured, and it will be compared to theoretical models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izaki, Kenta, E-mail: izaki@med.kobe-u.ac.jp; Yamaguchi, Masato; Matsumoto, Ippei
2011-06-15
A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our techniquemore » for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.« less
Two-mode elliptical-core weighted fiber sensors for vibration analysis
NASA Technical Reports Server (NTRS)
Vengsarkar, Ashish M.; Murphy, Kent A.; Fogg, Brian R.; Miller, William V.; Greene, Jonathan A.; Claus, Richard O.
1992-01-01
Two-mode, elliptical-core optical fibers are demonstrated in weighted, distributed and selective vibration-mode-filtering applications. We show how appropriate placement of optical fibers on a vibrating structure can lead to vibration mode filtering. Selective vibration-mode suppression on the order of 10 dB has been obtained using tapered two-mode, circular-core fibers with tapering functions that match the second derivatives of the modes of vibration to be enhanced. We also demonstrate the use of chirped, two-mode gratings in fibers as spatial modal sensors that are equivalents of shaped piezoelectric sensors.
Human aortic allograft: an excellent conduit choice for superior vena cava reconstruction
2014-01-01
Superior vena cava (SVC) reconstruction is occasionally required in the treatment of benign and malignant conditions. We report a patient with symptomatic SVC obstruction secondary to mediastinal fibrosis successfully reconstructed with an aortic allograft. PMID:24428914
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fretz, V.; Binkert, C. A., E-mail: Christoph.Binkert@ksw.c
May-Thurner syndrome is known as compression of the left common iliac vein by the right common iliac artery. We describe a case of an atypical compression of the inferior vena cava by the right common iliac artery secondary to a high aortic bifurcation. Despite an extensive collateral network, there was a significant venous gradient between the iliac veins and the inferior vena cava above the compression. After stenting the venous pressure gradient disappeared. Follow-up 4 months later revealed a good clinical response with a patent stent.
Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.
Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca
2006-09-01
Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.
Lee, Ji-Hyeok; Ko, Ju-Young; Oh, Jae-Young; Kim, Chul-Young; Lee, Hee-Ju; Kim, Jaeil; Jeon, You-Jin
2014-09-01
Various bioactive phlorotannins of Ecklonia cava (e.g., dieckol, eckol, 6,6-bieckol, phloroglucinol, phloroeckol, and phlorofucofuroeckol-A) are reported. However, their isolation and purification are not easy. Centrifugal partition chromatography (CPC) can be used to efficiently purify the various bioactive-compounds efficiently from E. cava. Phlorotannins are successfully isolated from the ethyl acetate (EtOAc) fraction of E. cava by CPC with a two-phase solvent system comprising n-hexane:EtOAc:methanol:water (2:7:3:7, v/v) solution. The dieckol (fraction I, 40.2mg), phlorofucofuroeckol-A (fraction III, 31.1mg), and fraction II (34.1mg) with 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are isolated from the crude extract (500 mg) by a one-step CPC system. The purities of the isolated dieckol and phlorofucofuroeckol-A are ⩾90% according to high performance liquid chromatography (HPLC) and electrospray ionization multi stage tandem mass spectrometry analyses. The purified 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are collected from fraction II by recycle-HPLC. Thus, the CPC system is useful for easy and simple isolation of phlorotannins from E. cava. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chessa, Massimo; Carminati, Mario; Cinteză, Eliza Elena; Butera, Gianfranco; Giugno, Luca; Arcidiacono, Carmelo; Piazza, Luciane; Bulescu, Nicolae Cristian; Pome, Giuseppe; Frigiola, Alessandro; Giamberti, Alessandro
2016-01-01
Abnormal connection of the right superior caval vein to the left atrium is an uncommon systemic vein drainage anomaly, with only a few cases reported among congenital heart disease (CHD), around 20 cases published in the medical literature. The inferior vena cava connection with the left atrium, also very rare, can appear directly or in heterotaxy. Clinical suspicion arises due to the presence of cyanosis in the absence of other specific clinical signs (without other associated CHD). We present the cases of two children with abnormal superior and inferior systemic venous return. The first case is an abnormal connection of right superior vena cava to the left atrium associated with persistent left superior vena cava draining into the right atrium through the coronary sinus. The second case is an interruption of the inferior vena cava with hemiazygos continuation, drained into the left superior vena cava, which drained into the left atrium. The diagnosis was imagistic - echocardiography and angiography. Surgical treatment solutions vary from one case to another, usually following anatomic correction. Hypoxia accompanied by cyanosis must bring into question the pathology of systemic venous drainage anomaly, after other common causes have been excluded. Surgery is indicated in all cases due to the risk associated with the presence of right-to-left shunt.
Idrees, Danish; Prakash, Amresh; Haque, Md Anzarul; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz
2016-09-01
Carbonic anhydrase VA (CAVA) is primarily expressed in the mitochondria and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis and neuronal transmission. To understand the biophysical properties of CAVA, we carried out a reversible urea-induced isothermal denaturation at pH 7.0 and 25°C. Spectroscopic probes, [θ]222 (mean residue ellipticity at 222 nm), F344 (Trp-fluorescence emission intensity at 344 nm) and Δε280 (difference absorption at 280 nm) were used to monitor the effect of urea on the structure and stability of CAVA. The urea-induced reversible denaturation curves were used to estimate [Formula: see text], Gibbs free energy in the absence of urea; Cm, the mid-point of the denaturation curve, i.e. molar urea concentration ([urea]) at which ΔGD = 0; and m, the slope (=∂ΔGD/∂[urea]). Coincidence of normalized transition curves of all optical properties suggests that unfolding/refolding of CAVA is a two-state process. We further performed 40 ns molecular dynamics simulation of CAVA to see the dynamics at different urea concentrations. An excellent agreement was observed between in silico and in vitro studies.
NASA Astrophysics Data System (ADS)
Jeong, Junho; Kim, Seungkeun; Suk, Jinyoung
2017-12-01
In order to overcome the limited range of GPS-based techniques, vision-based relative navigation methods have recently emerged as alternative approaches for a high Earth orbit (HEO) or deep space missions. Therefore, various vision-based relative navigation systems use for proximity operations between two spacecraft. For the implementation of these systems, a sensor placement problem can occur on the exterior of spacecraft due to its limited space. To deal with the sensor placement, this paper proposes a novel methodology for a vision-based relative navigation based on multiple position sensitive diode (PSD) sensors and multiple infrared beacon modules. For the proposed method, an iterated parametric study is used based on the farthest point optimization (FPO) and a constrained extended Kalman filter (CEKF). Each algorithm is applied to set the location of the sensors and to estimate relative positions and attitudes according to each combination by the PSDs and beacons. After that, scores for the sensor placement are calculated with respect to parameters: the number of the PSDs, number of the beacons, and accuracy of relative estimates. Then, the best scoring candidate is determined for the sensor placement. Moreover, the results of the iterated estimation show that the accuracy improves dramatically, as the number of the PSDs increases from one to three.
Komatsu, Shohei; Kido, Masahiro; Asari, Sadaki; Toyama, Hirochika; Ajiki, Tetsuo; Demizu, Yusuke; Terashima, Kazuki; Okimoto, Tomoaki; Sasaki, Ryohei; Fukumoto, Takumi
2017-12-01
Hepatocellular carcinoma accompanied with inferior vena cava tumor thrombus carries a dismal prognosis, and the feasibility of local treatment has remained controversial. The present study aimed to compare the outcomes of particle radiotherapy and liver resection in patients with hepatocellular carcinoma with inferior vena cava tumor thrombus. Thirty-one and 19 patients, respectively, underwent particle radiotherapy and liver resection for hepatocellular carcinoma with inferior vena cava tumor thrombus. A matched-pair analysis was undertaken to compare the short- and long-term outcomes according to tumor stage determined using the tumor-node-metastasis classification. Both stages IIIB and IV (IVA and IVB) patients were well-matched for 12 factors, including treatment policy and patient and tumor characteristics. The median survival time of matched patients with stage IIIB tumors in the particle radiotherapy group was greater than that in the liver resection group (748 vs 272 days, P = .029), whereas no significant difference was observed in the median survival times of patients with stage IV tumors (239 vs 311 days, respectively). There were significantly fewer treatment-related complications of grade 3 or greater in the particle radiotherapy group (0%) than in the liver resection group (26%). Particle radiotherapy is potentially preferable in hepatocellular carcinoma patients with stage IIIB inferior vena cava tumor thrombus and at least equal in efficiency to liver resection in those with stage IV disease, while causing significantly fewer complications. Considering the relatively high survival and low invasiveness of particle radiotherapy when compared to liver resection, this approach may represent a novel treatment modality for hepatocellular carcinoma with inferior vena cava tumor thrombus. Copyright © 2017 Elsevier Inc. All rights reserved.
Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru
2015-09-01
Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.
Aydın, Kutlay; Tokur, Murat Emre; Ergan, Begüm
2018-01-01
A persistent left-sided superior vena cava (PLSVC) is the most frequent abnormality of the venous system; however, it is not a very well-known variation among physicians. Herein we report the case of a patient with a PLSVC who was diagnosed after central venous catheterization (CVC). An 80-year-old man was admitted to the emergency room with cardiopulmonary arrest. After the return of spontaneous circulation, CVC was blindly performed from the left jugular vein without any complications. However, routine chest X-ray after catheterization revealed that the catheter was moving down directly to the left heart. Thoracic computed tomography showed the right brachiocephalic vein draining into the left brachiocephalic vein and forming the left superior vena cava in front of the aortic arch. The left superior vena cava merged into the right atrium after crossing the left pulmonary artery. CVC is widely used in clinical practice, and therefore clinicians should be aware of possible variations in central veins, particularly during blind catheterization.
Mizuno, A; Nakamura, Y; Takayasu, H; Saitoh, H
1993-05-01
Successful repair of a 8-month-old girl with polysplenia was reported. The cardiovascular anomalies were TAPVC (II b), incomplete ECD, interruption of inferior vena cava with hemiazygos continuation, bilateral superior vena cava, and left superior vena cava draining into the coronary sinus. Cardiopulmonary bypass was established with ascending aortic perfusion and caval cannulation. A left superior vena cava was directly cannulated after establishing partial bypass. In this case the left pulmonary vein drained into the right atrium near the orifice of the coronary sinus, so the atrial septal flap was made and sutured between the orifice of the left pulmonary vein and the coronary sinus in order to avoid late pulmonary vein obstruction. Then, atrium was separated by an intraatrial baffle which was sutured to the atrial septal flap. Recently, it becomes possible to surgical repair of polysplenia syndrome according to the advancements of the diagnostic methods, cardiopulmonary bypass, and the technique of the open heart surgery.
Truman, A T; Rao, P S; Kulangara, R J
1980-01-01
A 4-month-old infant with cyanosis but without other abnormal cardiac findings is presented in whom the diagnosis of anomalous systemic venous connection to the left atrium was made by contrast echocardiography. The diagnosis was later confirmed by cardiac catheterisation and selective cineangiography. When saline was injected into a vein on the dorsum of each hand while echocardiographically recording the cardiac structures, the left atrium, left ventricle, and aorta were opacified without visualisation of the right ventricle. Similar study with injection into the right foot produced opacification of the right ventricle without visualisation of the left-sided structures. These data suggested normal drainage of the inferior vena cava with anomalous connection of the superior vena cava to the left atrium. A review of the previously reported cases of anomalous connection of the right superior vena cava to the left atrium is presented together with the possible embryological origin of this anomaly. Images PMID:7459157
Construction of Continental Crust at the Central American and Philippines Arc Systems
NASA Astrophysics Data System (ADS)
Whattam, S. A.; Stern, R. J.
2016-12-01
Whether or not magmatic arcs evolve compositionally with time and the processes responsible remain controversial. Resolution of this question requires reconstructing arc geochemical evolution at the level of discrete arc systems, as has been done for IBM, Central America, and the Greater Antilles. Emphasis should be on arcs built on oceanic crust because interaction with continental crust complicates interpretations. The Philippines are a particularly attractive target because this may be the best example where proto-continental crust has been generated and processed in Cretaceous and younger time. Here, we show how this question could be addressed for the Philippines using the well-studied Central American Volcanic Arc System (CAVAS) as an example. For the CAVAS, we avoided the northern arc segment because these are (Guatemala) or maybe (El Salvador) sections built on continental crust. Geochemical and isotopic data were compiled for 1031 samples of lavas and intrusive rocks from the 1100 km-long segment built on thickened, initially plume-derived oceanic crust over its 75 million year lifespan (Panama, Costa Rica, Nicaragua) . The most striking observation is the overall evolution of the CAVAS to more incompatible element enriched and ultimately continental-like compositions with time. Models entailing progressive arc magmatic enrichment are generally supported by the CAVAS record. Progressive enrichment of the oceanic CAVAS with time reflects changes in mantle wedge composition and decreased melting due to arc crust thickening, which was kick-started by the involvement of enriched plume mantle. Progressive crustal thickening and associated changes in the sub-arc thermal regime resulted in decreasing degrees of partial melting over time, which allowed for progressive enrichment of the CAVAS and ultimately the production of continental-like crust in Panama and Costa Rica by 16-10 Ma. Our similar study of the Philippine Arc system is in its infancy but earlier studies have shown that older magmatic rocks are tholeiitic and MORB-like whereas younger ones are invariably calc-alkaline and arc-like. Results of the Philippines Arc study will be compared with the CAVAS and other magmatic arc systems comprised of continental crust.
Intraatrial baffle repair of isolated ventricular inversion with left atrial isomerism.
McElhinney, D B; Reddy, V M; Silverman, N H; Hanley, F L
1996-11-01
Isolated ventricular inversion with left atrial isomerism, partial anomalous pulmonary venous connection, and interruption of the inferior vena cava with azygos continuation to a right superior vena cava was diagnosed by echocardiography in a neonate. At 48 days of age, the patient underwent successful anatomic correction with redirection of flow from the superior vena cava and hepatic veins to the left-sided tricuspid valve, and flow from the pulmonary veins to the right-sided mitral valve. In the present report, the surgical techniques of this case are described, along with a survey of the surgical literature covering anatomic repair of isolated ventricular inversion.
Janssen, S; van Donselaar-van der Pant, K A M I; van der Weerd, N C; Develter, W; Bemelman, F J; Grobusch, M P; Idu, M M; Ten Berge, I J M
2013-02-01
Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous collateral veins of the abdominal wall contra-laterally to the renal transplant. Cultures from abdominal wall micro-abscesses yielded Prevotella bivia as the causative agent. This complication has not been described before in the context of renal transplantation. The pathogenesis and management of this serious complication are discussed in this paper.
Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N
2013-09-01
A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.
Right Site, Wrong Route - Cannulating the Left Internal Jugular Vein.
Paik, Peter; Arukala, Sanjay K; Sule, Anupam A
2018-01-09
Central venous catheters are placed in approximately five million patients annually in the US. The preferred site of insertion is one with fewer risks and easier access. Although the right internal jugular vein is preferred, on occasion, the left internal jugular may have to be accessed. A patient was admitted for septic shock, cerebrovascular accident, and non-ST-segment elevation myocardial infarction. A central venous line was needed for antibiotic and vasopressor administration. Due to trauma from a fall to the right side and previously failed catheterization attempts at the left subclavian and femoral veins, the left internal jugular vein was accessed. On chest radiography for confirmation, the left internal jugular central venous catheter was seen projecting down the left paraspinal region. It did not take the expected course across the midline toward the right and into the superior vena cava (SVC). A review of a computed tomography (CT) scan of the chest with contrast done on a prior admission revealed a duplicated SVC on the left side that had not been reported in the original CT scan interpretation. A left-sided SVC is present in approximately 0.3% to 0.5% of the population, with 90% of these draining into the coronary sinus. During placements of central venous lines and pacemakers, irritation of the coronary sinus may result in hypotension, arrhythmia, myocardial ischemia, or cardiac arrest. A widened mediastinum can be an indication of a duplicated SVC. When attempting a left internal jugular vein central venous catheter placement, it is important to be aware of venous anomalies in order to prevent complications.
Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu
2018-04-25
To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P < .001). The primary patency rate of the contralateral CIV stent was 70% at 20 months. Contralateral DVT after CIV stent implantation has a relatively high incidence and often occurs late during follow-up. Overextension of the CIV stent to the IVC is associated with development of contralateral DVT, and VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.
Higutchi, C; Sarraf, Y S; Nardino, É P; Pereira, W M G; Daboin, B E G; Carvalho, L E W; Correa, J A
2017-01-01
This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins) who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC) and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis.
Ait-Oufella, Hafid; Boelle, Pierre-Yves; Galbois, Arnaud; Baudel, Jean-Luc; Margetis, Dimitri; Alves, Mikael; Offenstadt, Georges; Maury, Eric; Guidet, Bertrand
2012-06-28
Previous studies have shown a good agreement between central venous pressure (CVP) measurements from catheters placed in superior vena cava and catheters placed in the abdominal cava/common iliac vein. However, the influence of intra-abdominal pressure on such measurements remains unknown. We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure. A total of 30 patients were enrolled (age 62 ± 14 years; SAPS II 62 (52-76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2-5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14 mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P = 0.002). We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14 mmHg.
Vohra, H A; Phillips, N J; Nel, L; Diprose, P; Ohri, S K
2010-06-01
We report a unilateral right atrial familial myxoma with a multicentric nature discovered during cardiac surgery. After the patient was weaned off cardiopulmonary bypass, an inferior vena cava myxoma was discovered with intra-operative trans-oesophageal echocardiogram (TOE) which had been missed preoperatively and during surgery.
Ulloa-Ricardez, Alfredo; Romero-Espinoza, Lizett; Estrada-Loza, María de Jesús; González-Cabello, Héctor Jaime; Núñez-Enríquez, Juan Carlos
2016-08-01
Central venous catheter (CVC) installation is essential for the treatment of critically ill neonates; however, it is associated with the development of neonatal intracardiac thrombosis, which is a complication that is associated with a poor prognosis. We aimed to identify specific risk factors for the development of intracardiac thrombosis in the right atrium (RA) and superior vena cava (SVC) related to the use of CVC in critically ill neonates. A case-control study was conducted at the tertiary referral neonatal intensive care unit of the Pediatric Hospital Siglo XXI in Mexico City, Mexico from 2008 to 2013. The included cases (n = 43) were de novo patients with intracardiac thrombosis in the RA and SVC diagnosed by echocardiography. The controls (n = 43) were neonates without intracardiac thrombosis or thrombosis at other sites. A logistic regression analysis was conducted, and odds ratios (ORs) and 95% confidence intervals (95% CIs) were calculated. The independent risk factors for intracardiac thrombosis in the RA and SVC were the surgical cut-down insertion technique (OR = 2.98; 95% CI: 1.18-9.10), a maternal history of gestational diabetes/diabetes mellitus (OR = 10.64; 95% CI: 1.13-121.41), Staphylococcus epidermidis infection (OR = 7.09; 95% CI: 1.09-45.92), and CVC placement in the SVC (OR = 5.77; 95% CI: 1.10-30.18). This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study. Copyright © 2015. Published by Elsevier B.V.
A rare nidus for pulmonary thromboembolism after vertebroplasty.
Vallabhajosyula, Saraschandra; Sundaragiri, Pranathi Rao; Bansal, Ojas; Townley, Theresa A
2013-10-23
Percutaneous vertebroplasty is used to treat osteoporotic compression fractures and bone loss due to malignancy. The cement used can serve as a potential nidus for pulmonary thromboembolism (PTE). An 87-year-old woman with recent L2 vertebroplasty presented with abdominal pain and shortness of breath. Thoracoabdominal CT scan revealed extensive bilateral pulmonary emboli associated with a 9 cm cement fragment in the inferior vena cava (IVC) extending proximally from the level of the right superior renal vein, likely secondary to cement leak from the vertebral plexus into the IVC. She refused catheter extraction was managed conservatively. There are 51 reported cases of cement pulmonary embolism. IVC foreign bodies serving as a nidus for PTE have been reported with IVC filters with an incidence of 6.2%. This is the second reported case of vertebroplasty cement serving as a nidus for PTE. Treatment depends on time interval between the procedure and the symptom onset.
Risk-adapted management of pulmonary embolism.
Barco, Stefano; Konstantinides, Stavros V
2017-03-01
The presence and severity of right ventricular (RV) dysfunction is a key determinant of prognosis in the acute phase of pulmonary embolism (PE). Risk-adapted treatment strategies continue to evolve, tailoring initial management to the clinical presentation and the functional status of the RV. Beyond pharmacological and, if necessary, mechanical circulatory support, systemic thrombolysis remains the mainstay of treatment for hemodynamically unstable patients; in contrast, it is not routinely recommended for intermediate-risk PE. Catheter-directed pharmacomechanical reperfusion treatment represents a promising option for minimizing bleeding risk; for reduced-dose intravenous thrombolysis, the data are still preliminary. Non-vitamin K-dependent oral anticoagulants, directly inhibiting factor Xa (rivaroxaban, apixaban, edoxaban) or thrombin (dabigatran), have simplified initial and long-term anticoagulation for PE while reducing major bleeding risk. Use of vena cava filters should be restricted to selected patients with absolute contraindications to anticoagulation, or PE recurrence despite adequately dosed anticoagulants. © 2017 Elsevier Ltd. All rights reserved.
Interaction of platelets, fibrinogen and endothelial cells with plasma deposited PEO-like films
NASA Astrophysics Data System (ADS)
Yang, Zhilu; Wang, Jin; Li, Xin; Tu, Qiufen; Sun, Hong; Huang, Nan
2012-02-01
For blood-contacting biomedical implants like retrievable vena cava filters, surface-based diagnostic devices or in vivo sensors, limiting thrombosis and cell adhesion is paramount, due to a decrease even failure in performance. Plasma deposited PEO-like films were investigated as surface modifications. In this work, mixed gas composed of tetraethylene glycol dimethyl ether (tetraglyme) vapor and oxygen was used as precursor. It was revealed that plasma polymerization under high ratio of oxygen/tetraglyme led to deposition of the films that had high content of ether groups. This kind of PEO-like films had good stability in phosphate buffer solution. In vitro hemocompatibility and endothelial cell (EC) adhesion revealed low platelet adhesion, platelet activation, fibrinogen adhesion, EC adhesion and proliferation on such plasma deposited PEO-like films. This made it a potential candidate for the applications in anti-fouling surfaces of blood-contacting biomedical devices.
Engineering fabrics in transportation construction
NASA Astrophysics Data System (ADS)
Herman, S. C.
1983-11-01
The following areas are discussed: treatments for reduction of reflective cracking of asphalt overlays on jointed-concrete pavements in Georgia; laboratory testing of fabric interlayers for asphalt concrete paving: interim report; reflection cracking models: review and laboratory evaluation of engineering fabrics; optimum-depth method for design of fabric-reinforced unsurfaced roads; dynamic test to predict field behavior of filter fabrics used in pavement subdrains; mechanism of geotextile performance in soil-fabric systems for drainage and erosion control; permeability tests of selected filter fabrics for use with a loess-derived alluvium; geotextile filter criteria; use of fabrics for improving the placement of till on peat foundation; geotextile earth-reinforced retaining wall tests: Glenwood Canyon, Colorado; New York State Department of Transportation's experience and guidelines for use of geotextiles; evaluation of two geotextile installations in excess of a decade old; and, long-term in situ properties of geotextiles.
Biofouling attractants from a brown marine alga Ecklonia cava.
Sidharthan, M; Viswanadh, G S; Kim, Kyoung Ho; Kim, Hyuk Jun; Shin, H W
2007-04-01
In recent years, industrial pollutants and the mountain forest fire ashes released into seawater cause damage to the marine environment, mainly it reduces the algal productivity in the inter tidal region. To get recover from the stress due to pollutants and to increase the growth and development of biofouling algae (benthic organisms), Ecklonia cava extract was investigated for its biofouling attracting efficiency. Bioactive guided fractions of E. cava extract derived from column chromatography were tested against spore attachment of a fouling alga, Ulva pertusa. Fraction B showed increased spore attachment rate with a maximum of 92 +/- 5%. This fraction was further analysed on HPLC, GC-Mass and NMR, deduced as pentadecanoic acid.
Parsaee, Mozhgan; Pouraliakbar, Hamidreza; Ghadrdoost, Behshid; Moosavi, Jamal; Behjati, Mohaddeseh
2018-06-10
The most commonly reported collateral systems in the setting of superior vena cava obstruction are azygos venous system, vertebral venous system, external and internal thoracic venous system based on McLntire and Sykes classification. A 49-year-old female with renal disease complained dyspnea on exertion. Transesophageal echocardiography showed significant mitral annular calcification, large multi-lobulated mass at posterior aspect of RA, and complete obstruction of superior vena cava by thrombus formation. Computed tomography angiography showed a collateral vein to the left atrium (LA) roof. This case report is the first one which shows development of collateral vein from right subclavian to LA. © 2018 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carnevale, Francisco Cesar, E-mail: fcarnevale@uol.com.br; Santos, Aline Cristine Barbosa; Tannuri, Uenis
We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge ofmore » the stent.« less
Optimized Multi-Spectral Filter Array Based Imaging of Natural Scenes.
Li, Yuqi; Majumder, Aditi; Zhang, Hao; Gopi, M
2018-04-12
Multi-spectral imaging using a camera with more than three channels is an efficient method to acquire and reconstruct spectral data and is used extensively in tasks like object recognition, relighted rendering, and color constancy. Recently developed methods are used to only guide content-dependent filter selection where the set of spectral reflectances to be recovered are known a priori. We present the first content-independent spectral imaging pipeline that allows optimal selection of multiple channels. We also present algorithms for optimal placement of the channels in the color filter array yielding an efficient demosaicing order resulting in accurate spectral recovery of natural reflectance functions. These reflectance functions have the property that their power spectrum statistically exhibits a power-law behavior. Using this property, we propose power-law based error descriptors that are minimized to optimize the imaging pipeline. We extensively verify our models and optimizations using large sets of commercially available wide-band filters to demonstrate the greater accuracy and efficiency of our multi-spectral imaging pipeline over existing methods.
Optimized Multi-Spectral Filter Array Based Imaging of Natural Scenes
Li, Yuqi; Majumder, Aditi; Zhang, Hao; Gopi, M.
2018-01-01
Multi-spectral imaging using a camera with more than three channels is an efficient method to acquire and reconstruct spectral data and is used extensively in tasks like object recognition, relighted rendering, and color constancy. Recently developed methods are used to only guide content-dependent filter selection where the set of spectral reflectances to be recovered are known a priori. We present the first content-independent spectral imaging pipeline that allows optimal selection of multiple channels. We also present algorithms for optimal placement of the channels in the color filter array yielding an efficient demosaicing order resulting in accurate spectral recovery of natural reflectance functions. These reflectance functions have the property that their power spectrum statistically exhibits a power-law behavior. Using this property, we propose power-law based error descriptors that are minimized to optimize the imaging pipeline. We extensively verify our models and optimizations using large sets of commercially available wide-band filters to demonstrate the greater accuracy and efficiency of our multi-spectral imaging pipeline over existing methods. PMID:29649114
Günal, N; Bilgiç, A; Lenk, M K; Yurdakul, Y; Sarigül, A; Ispir, S
1996-03-01
A 4-year-old boy with abnormal connection of the inferior vena cava to the left atrium and double outlet right ventricle and right atrial isomerism is presented. The anomalies were detected by echocardiography and angiography, and later verified through surgical intervention.
Scimitar sign with normal pulmonary venous drainage and anomalous inferior vena cava.
Herer, B; Jaubert, F; Delaisements, C; Huchon, G; Chretien, J
1988-01-01
A case of the scimitar sign due to an anomaly of the right sided pulmonary vein with normal drainage into the left atrium was associated with an azygos continuation of the inferior vena cava. Digital subtraction angiography allows the identification of these rare congenital vascular malformations. Images PMID:3175980
Shin, Hankei; Mori, Mitsuharu; Matayoshi, Toru; Suzuki, Ryo; Yozu, Ryohei
2004-08-01
A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cannulation via the right atrial wall and placing a snare around the inferior vena cava were impossible. With a cardiopulmonary bypass using vacuum-assisted venous drainage, the tumor was successfully resected and the tricuspid valve was replaced with a bioprosthetic valve without snaring the inferior vena cava. Postoperative histological examination demonstrated the tumor to be a large B-cell non-Hodgkin type malignant lymphoma. When the tumor is large and it is difficult to establish total cardiopulmonary bypass, the vacuum-assisted cardiopulmonary bypass is a useful option. This can achieve a bloodless operative field and is not blocked by the incoming air, due to the venous drainage being continually pressure-regulated.
Guo, Gongliang; Yang, Lili; Wu, Jinyi; Sun, Liqun
2017-01-01
Abstract Background: Dextrocardia, or right-lying heart, is an uncommon congenital heart disease in which the apex of the heart is located on the right side of chest. Persistent left superior vena cava (PLSVA) is a rare venous anomaly that is often associated with the abnormalities of cardiac transduction system. A case with combination of dextrocardia, persistent left superior vena cava, and sick sinus syndrome has not been reported. Methods: We used different techniques including cardiac color Doppler echocardiography, 24-hour Holter monitoring, and abdominal ultrasound to make a diagnosis and treated the patient by implanting a VVI pacemaker. Results: A 50-year-old woman was admitted with a syncope. Angiography of the right atrium and superior vena cava, echocardiography, electrocardiography, and abdominal ultrasound revealed the presence of the combination of mirror image dextrocardia, PLSVA, and sick sinus syndrome. The complex structural anomalies presented great technical challenges for interventional treatments. After thorough examination and understanding of the structural anatomy and anomalies of the superior and inferior vena cava and cardiac chambers, we successfully treated this patient by implanting a VVI pacemaker. Conclusion: Physicians must be aware of the complexity of the morphological and anatomical structures of dextrocardia accompanying PLSVC. Given that the diagnosis of situs inversus was performed at a relatively advanced age, it is therefore important to make such a correct diagnosis followed by appropriate therapeutic intervention. PMID:28151908
Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel
2018-02-23
Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Melancon, A; Jacobsen, M; Salatan, F
Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GEmore » Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.« less
Ito, Hiroki; Murata, Masaya; Ide, Yujiro; Sugano, Mikio; Kanno, Kazuyoshi; Imai, Kenta; Ishido, Motonori; Fukuba, Ryohei; Sakamoto, Kisaburo
2016-01-01
OBJECTIVES Fontan candidates with mixed totally anomalous pulmonary venous connection often have postoperative pulmonary venous obstruction after cavopulmonary anastomosis. Because some pulmonary venous obstructions have no intimal hypertrophy at reoperation, we considered such pulmonary venous obstructions to be caused by 3D deformities arising from dissection or mobilization of the vessels, and hypothesized that keeping the pulmonary venous branches in a natural position could avoid such obstruction. Here, we evaluated a modified hemi-Fontan strategy consisting of minimal dissection with no division of vessels and patch separation between systemic and pulmonary venous flow. METHODS We retrospectively reviewed clinical records of infants with a functional single ventricle and supracardiac anomalous pulmonary venous connection who had undergone this procedure between 2002 and 2012. RESULTS Nine infants underwent this procedure (median age, 5.6 months; range 3.2–30), all with right atrial isomerism and several pulmonary venous branches directly and separately connecting to the superior vena cava. In 5 patients, all pulmonary veins drained into the superior vena cava; in 1, the right pulmonary veins drained into the superior vena cava and in 3, a pulmonary venous branch drained into the superior vena cava. The median follow-up was 6.9 years (0.8–13 years). Three patients underwent reoperation for postoperative pulmonary venous obstruction caused by intimal hypertrophy; however, we confirmed no pulmonary venous obstruction caused by 3D deformities on the pulmonary venous branches connecting separately to the superior vena cava. Although 2 patients were effectively relieved from pulmonary venous obstruction, 1 died due to recurrent pulmonary venous obstruction. There was no late death and no sinus-node dysfunction. Eight patients underwent successful Fontan operation and catheterization. The median interval from the Fontan operation to the latest catheterization was 3.7 years (0.9–3.7 years). The median arterial oxygen saturation was 94% (91–97%) and the central venous pressure was 12 mmHg (8–14 mmHg); no deficiency of pulmonary arteries and veins was noted. CONCLUSIONS For patients with functional single ventricle and anomalous pulmonary venous connections to the superior vena cava, our novel strategy of second-stage palliation could avoid postoperative pulmonary venous obstruction caused by 3D deformities, but may not eliminate pulmonary venous obstruction caused by intimal hypertrophy. PMID:26860898
Linear variable narrow bandpass optical filters in the far infrared (Conference Presentation)
NASA Astrophysics Data System (ADS)
Rahmlow, Thomas D.
2017-06-01
We are currently developing linear variable filters (LVF) with very high wavelength gradients. In the visible, these filters have a wavelength gradient of 50 to 100 nm/mm. In the infrared, the wavelength gradient covers the range of 500 to 900 microns/mm. Filter designs include band pass, long pass and ulta-high performance anti-reflection coatings. The active area of the filters is on the order of 5 to 30 mm along the wavelength gradient and up to 30 mm in the orthogonal, constant wavelength direction. Variation in performance along the constant direction is less than 1%. Repeatable performance from filter to filter, absolute placement of the filter relative to a substrate fiducial and, high in-band transmission across the full spectral band is demonstrated. Applications include order sorting filters, direct replacement of the spectrometer and hyper-spectral imaging. Off-band rejection with an optical density of greater than 3 allows use of the filter as an order sorting filter. The linear variable order sorting filters replaces other filter types such as block filters. The disadvantage of block filters is the loss of pixels due to the transition between filter blocks. The LVF is a continuous gradient without a discrete transition between filter wavelength regions. If the LVF is designed as a narrow band pass filter, it can be used in place of a spectrometer thus reducing overall sensor weight and cost while improving the robustness of the sensor. By controlling the orthogonal performance (smile) the LVF can be sized to the dimensions of the detector. When imaging on to a 2 dimensional array and operating the sensor in a push broom configuration, the LVF spectrometer performs as a hyper-spectral imager. This paper presents performance of LVF fabricated in the far infrared on substrates sized to available detectors. The impact of spot size, F-number and filter characterization are presented. Results are also compared to extended visible LVF filters.
Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.
Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée
2012-10-01
We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.
Transection of the inferior vena cava from blunt thoracic trauma: case reports.
Peitzman, A B; Udekwu, A O; Pevec, W; Albrink, M
1989-04-01
Blunt thoracic trauma is a frequent cause of death in multiple trauma victims. Myocardial rupture may occur in up to 65% of patients who die with thoracic injuries. Two cases are presented with intrapericardial transection of the inferior vena cava, pericardial rupture, and myocardial rupture from blunt thoracic trauma. Both patients died.
Retrieval of Cement Embolus from Inferior Vena Cava After Percutaneous Vertebroplasty
DOE Office of Scientific and Technical Information (OSTI.GOV)
Athreya, S., E-mail: sathreya@stjoes.c; Mathias, N.; Rogers, P.
Percutaneous vertebroplasty is an accepted treatment for painful vertebral compression fractures caused by osteoporosis and malignant disease. Venous leakage of cement and pulmonary cement embolism have been reported complications. We describe a paravertebral venous cement leak resulting in the deposition of a cement cast in the inferior vena cava and successful retrieval of the cement embolus.
Latchana, Nicholas; Dowell, Joshua D.; Taani, Jamal Al; Michaels, Anthony; Elkhammas, Elmadhi; Black, Sylvester M.
2015-01-01
Inferior vena cava thrombosis is a rare occurrence after an orthotopic liver transplant that is associated with a high rate of retransplant and mortality. There is no consensus regarding the optimal therapeutic strategy. Surgical management, including thrombectomy with revision of the cavocaval anastomosis, has been described. With the use of endovascular therapies, several minimally invasive approaches are available that are effective and avoid the high morbidity associated with reoperative surgery. We describe our successful experience using an approach after a liver transplant in which the inferior vena cava thrombosis in a patient presenting with acute renal failure, anorexia, weight loss, and fatigue using an ultrasound-accelerated, catheter-directed thrombolysis platform in conjunction with systemic anticoagulation. PMID:24918871
Partial anomalous pulmonary venous connection to the superior vena cava.
Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto
2011-04-01
We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Effectiveness of in-room air filtration and dilution ventilation for tuberculosis infection control.
Miller-Leiden, S; Lobascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
Effectiveness of In-Room Air Filtration and Dilution Ventilation for Tuberculosis Infection Control.
Miller-Leiden, S; Lohascio, C; Nazaroff, W W; Macher, J M
1996-09-01
Tuberculosis (TB) is a public health problem that may pose substantial risks to health care workers and others. TB infection occurs by inhalation of airborne bacteria emitted by persons with active disease. We experimentally evaluated the effectiveness of in-room air filtration systems, specifically portable air filters (PAFs) and ceiling-mounted air filters (CMAFs), in conjunction with dilution ventilation, for controlling TB exposure in high-risk settings. For each experiment, a test aerosol was continuously generated and released into a full-sized room. With the in-room air filter and room ventilation system operating, time-averaged airborne particle concentrations were measured at several points. The effectiveness of in-room air filtration plus ventilation was determined by comparing particle concentrations with and without device operation. The four PAFs and three CMAFs we evaluated reduced room-average particle concentrations, typically by 30% to 90%, relative to a baseline scenario with two air-changes per hour of ventilation (outside air) only. Increasing the rate of air flow recirculating through the filter and/or air flow from the ventilation did not always increase effectiveness. Concentrations were generally higher near the emission source than elsewhere in the room. Both the air flow configuration of the filter and its placement within the room were important, influencing room air flow patterns and the spatial distribution of concentrations. Air filters containing efficient, but non-high efficiency particulate air (HEPA) filter media were as effective as air filters containing HEPA filter media.
An approach for using soil surveys to guide the placement of water quality buffers
M.G. Dosskey; M.J. Helmers; D.E. Eisenhauer
2006-01-01
Vegetative buffers may function better for filtering agricultural runoff in some locations than in others because of intrinsic characteristics of the land on which they are placed. The objective of this study was to develop a method based on soil survey attributes that can be used to compare soil map units for how effectively a buffer installed in them could remove...
Regan, John Frederick
2014-09-09
Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.
Hall, David R.; Fox, Joe; Garner, Kory
2007-01-23
A drilling fluid filter for placement within a bore wall of a tubular drill string component comprises a perforated receptacle with an open end and a closed end. A hanger for engagement with the bore wall is mounted at the open end of the perforated receptacle. A mandrel is adjacent and attached to the open end of the perforated receptacle. A linkage connects the mandrel to the hanger. The linkage may be selected from the group consisting of struts, articulated struts and cams. The mandrel operates on the hanger through the linkage to engage and disengage the drilling fluid filter from the tubular drill string component. The mandrel may have a stationary portion comprising a first attachment to the open end of the perforated receptacle and a telescoping adjustable portion comprising a second attachment to the linkage. The mandrel may also comprise a top-hole interface for top-hole equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossi, Plinio; Arata, Flaminia Marcella; Bonaiuti, Paola
Purpose: To report the risk of fatal atrial migration with the Tempofilter. Methods: Among temporary filters, the high safety profile Tempofilter has been marketed as offering protection for up to 6 weeks. We implanted about 60 Tempofilters to prevent pulmonary embolism. The main indications were temporary thromboembolic risk, recurrent pulmonary embolism, and contraindication to or failure of anticoagulant therapy. Follow-up was performed regularly by plain abdominal film and Doppler ultrasound. Filters were removed about 4 weeks after placement. Results: We encountered three cases (5%) of atrial migration and one case of 5-cm cephalad displacement of the filter. Of the threemore » patients with atrial migration, two died within 3 days of implantation, one from a massive pulmonary embolism and the other with cardiac tamponade. One patient did not show any serious complications. Conclusions: The Tempofilter may actively migrate cranially and become dangerous in the case of migration within the heart.« less
Flatness-based control and Kalman filtering for a continuous-time macroeconomic model
NASA Astrophysics Data System (ADS)
Rigatos, G.; Siano, P.; Ghosh, T.; Busawon, K.; Binns, R.
2017-11-01
The article proposes flatness-based control for a nonlinear macro-economic model of the UK economy. The differential flatness properties of the model are proven. This enables to introduce a transformation (diffeomorphism) of the system's state variables and to express the state-space description of the model in the linear canonical (Brunowsky) form in which both the feedback control and the state estimation problem can be solved. For the linearized equivalent model of the macroeconomic system, stabilizing feedback control can be achieved using pole placement methods. Moreover, to implement stabilizing feedback control of the system by measuring only a subset of its state vector elements the Derivative-free nonlinear Kalman Filter is used. This consists of the Kalman Filter recursion applied on the linearized equivalent model of the financial system and of an inverse transformation that is based again on differential flatness theory. The asymptotic stability properties of the control scheme are confirmed.
Ari, Arzu; Dang, Truong; Al Enazi, Fahad H; Alqahtani, Mohammed M; Alkhathami, Abdulrahman; Qoutah, Rowaida; Almamary, Ahmad S; Fink, James B
2018-02-01
Placement of a heat moisture exchanger (HME) between aerosol generator and patient has been associated with greatly reduced drug delivery. The purpose of this study was to evaluate the effect of filtered and nonfiltered HMEs placed between nebulizer and patient on aerosol deposition and airway resistance (Raw) in simulated ventilator-dependent adults. An in vitro lung model was developed to simulate a mechanically ventilated adult (Vt 500 mL, RR 15/min, and PEEP 5 cmH 2 O, using two inspiratory flow rates 40 and 50 L/min) using an intubated adult manikin with an endotracheal tube (8 mmID). The bronchi of the manikin were connected to a Y-adapter through a collecting filter (Respirgard II) attached to a test lung through a heated humidifier (37°C producing 100% relative humidity) to simulate exhaled humidity. For treatment conditions, a nonfiltered HME (ThermoFlo™ 6070; ARC Medical) and filtered HMEs (ThermoFlo™ Filter; ARC Medical and PALL Ultipor; Pall Medical) were placed between the ventilator circuit at the endotracheal tube and allowed to acclimate to the exhaled heat and humidity for 30 minutes before aerosol administration. Airway resistance (cmH 2 O/L/s) was taken at 0, 10, 20, and 30 minutes after HME placement and after each of four aerosol treatments. Albuterol sulfate (2.5 mg/3 mL) was administered with jet (Misty Max 10; Airlife) and mesh (Aerogen Solo; Aerogen) nebulizers positioned in the inspiratory limb proximal to the Y-adapter. Control consisted of nebulization with no HME. Drug was eluted from filter at the end of the trachea and measured using spectrophotometry (276 nm). Greater than 60% of the control dose was delivered through the ThermoFlo. No significant difference was found between the first four treatments given by the jet (p = 0.825) and the mesh (p = 0.753) nebulizers. There is a small increase in Raw between pre- and post-four treatments with the jet (p = 0.001) and mesh (p = 0.015) nebulizers. Aerosol delivery through filtered HMEs was similar (<0.5%) across the four treatments. Airway resistance was similar using the ThermoFlo Filter. With the PALL Ultipor, changes in Raw increased with mesh nebulizer after treatment (p = 0.005). Changes in resistance pre- and post-treatment were similar with both filtered HMEs. The ThermoFlo™ nonfilter HME allowed the majority of the control dose to be delivered to the airway. Increases in Raw would likely not be outside of a tolerable range in ventilated patients. In contrast, filtered HMEs should not be placed between nebulizers and patient airways. Further research with other HMEs and materials is warranted.
Dalen, Havard; Gundersen, Guri H; Skjetne, Kyrre; Haug, Hilde H; Kleinau, Jens O; Norekval, Tone M; Graven, Torbjorn
2015-08-01
Routine assessment of volume state by ultrasound may improve follow-up of heart failure patients. We aimed to study the feasibility and reliability of focused pocket-size ultrasound examinations of the pleural cavities and the inferior vena cava performed by nurses to assess volume state at an outpatient heart failure clinic. Ultrasound examinations were performed in 62 included heart failure patients by specialized nurses with a pocket-size imaging device (PSID). Patients were then re-examined by a cardiologist with a high-end scanner for reference within 1 h. Specialized nurses were able to obtain and interpret images from both pleural cavities and the inferior vena cava and estimate the volume status in all patients. Time consumption for focused ultrasound examination was median 5 min. In total 26 patients had any kind of pleural effusion (in 39 pleural cavities) by reference. The sensitivity, specificity, positive and negative predictive values were high, all ≥ 92%. The correlations with reference were high for all measurements, all r ≥ 0.79. Coefficients of variation for end-expiratory dimension of inferior vena cava and quantification of pleural effusion were 10.8% and 12.7%, respectively. Specialized nurses were, after a dedicated training protocol, able to obtain reliable recordings of both pleural cavities and the inferior vena cava by PSID and interpret the images in a reliable way. Implementing focused ultrasound examinations to assess volume status by nurses in an outpatient heart failure clinic may improve diagnostics, and thus improve therapy. © The European Society of Cardiology 2014.
Effect of pH on structure, function, and stability of mitochondrial carbonic anhydrase VA.
Idrees, Danish; Shahbaaz, Mohd; Bisetty, Krishna; Islam, Asimul; Ahmad, Faizan; Hassan, Md Imtaiyaz
2017-02-01
Mitochondrial carbonic anhydrase VA (CAVA) catalyzes the hydration of carbon dioxide to produce proton and bicarbonate which is primarily expressed in the mitochondrial matrix of liver, and involved in numerous physiological processes including lipogenesis, insulin secretion from pancreatic cells, ureagenesis, gluconeogenesis, and neuronal transmission. To understand the effect of pH on the structure, function, and stability of CAVA, we employed spectroscopic techniques such as circular dichroism, fluorescence, and absorbance measurements in wide range of pH (from pH 2.0 to pH 11.5). CAVA showed an aggregation at acidic pH range from pH 2.0 to pH 5.0. However, it remains stable and maintains its secondary structure in the pH range, pH 7.0-pH 11.5. Furthermore, this enzyme has an appreciable activity at more than pH 7.0 (7.0 < pH ≤ 11.5) with maximum activity at pH 9.0. The maximal values of k cat and k cat /K m at pH 9.0 are 3.7 × 10 6 s -1 and 5.5 × 10 7 M -1 s -1 , respectively. However, this enzyme loses its activity in the acidic pH range. We further performed 20-ns molecular dynamics simulation of CAVA to see the dynamics at different pH values. An excellent agreement was observed between in silico and in vitro studies. This study provides an insight into the activity of CAVA in the pH range of subcellular environment.
Quantum Material Properties of 4d and 5d Transition Metal Oxides and Potential Applications
2015-05-26
11 2009): 0. doi: 10.1103/PhysRevB.80.184505 Y. Liu, I. G. Deac, P. Khalifah, R. J. Cava, Y. A. Ying, P. Schiffer , K. D. Nelson. Possible observation...Yiqun A. Ying, Karl Nelson, Iosef G. Deac, Peter Schiffer , Peter Khalifah, Robert J. Cava, and Ying Liu, "Magneto electrical transport properties and
Morphology of splenocaval congenital portosystemic shunts in dogs and cats.
White, R N; Parry, A T
2016-01-01
To describe the anatomy of congenital portosystemic shunts involving the splenic vein communicating with the caudal vena cava at the level of the epiploic foramen. A retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. Ninety-eight dogs and eight cats met the inclusion criteria of a congenital portosystemic shunt involving the splenic vein communicating with the prehepatic caudal vena cava plus recorded intra-operative mesenteric portovenography or computed tomography angiography and gross observations at surgery. All cases (both dogs and cats) had a highly consistent shunt that involved a distended gastrosplenic vein that communicated with the caudal vena cava at the level of the epiploic foramen via an anomalous left gastric vein. The morphology of the shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava and the subsequent development of preferential blood flow through an essentially normal portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the splenic vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
Anatomical basis of the liver hanging maneuver.
Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija
2005-01-01
The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).
Use of Nitinol Stents Following Recanalization of Central Venous Occlusions in Hemodialysis Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca; Saluja, Jasdeep S.
2007-07-15
Purpose. To retrospectively review the patency of endovascular interventions with nitinol stent placement for symptomatic central venous occlusions in hemodialysis patients. Methods. A retrospective review of all patients who underwent endovascular interventions for dysfunctional hemodialysis grafts and fistulas was performed from April 2004 to August 2006. A total of 6 patients presented with arm and/or neck and facial swelling and left brachiocephalic vein occlusion. The study group consisted of 3 men and 3 women with a mean age of 79.5 years (SD 11.2 years). Of these 6 patients, 1 had a graft and 5 had fistulas in the left arm.more » The primary indication for nitinol stent placement was technical failure of angioplasty following successful traversal of occluded central venous segments. Patency was assessed from repeat fistulograms and central venograms performed when patients redeveloped symptoms or were referred for access dysfunction determined by the ultrasound dilution technique. No patients were lost to follow-up. Results. Nitinol stent placement to obtain technically successful recanalization of occluded venous segments was initially successful in 5 of 6 patients (83%). In 1 patient, incorrect stent positioning resulted in partial migration to the superior vena cava requiring restenting to prevent further migration. Clinical success was observed in all patients (100%). Over the follow-up period, 2 patients underwent repeat intervention with angioplasty alone. Primary patency was 83.3% (95% CI 0.5-1.2) at 3 months, and 66.7% at 6 and 12 months (0.2-1.1, 0.1-1.2). Secondary patency was 100% at 12 months with 3 patients censored over that time period. Mean primary patency was 10.4 months with a mean follow-up of 12.4 months. No complications related to recanalization of the occluded central venous segments were observed. Conclusion. Our initial experience has demonstrated that use of nitinol stents for central venous occlusion in hemodialysis patients is associated with good mid-term patency and may exceed historical observations with prior use of Wallstents.« less
Archundia García, A; Gómez Alvarez, E; Ixcamparij Rosales, C; Blanco Canto, M; Hernández Ruiz, M A
2000-01-01
This is the diagnostic experiences as well as the surgical mode of treatment used in a 31 years old women suffering diversion of the inferior vena cava into the left atrium associated with atrial septal defect. The patient had been previously studied and operated thrice under conventional circumstances at different institutions in order to solve the septal defect. The hemodynamic solution had not been reached due to a missing pathological definition. The cineangiogram through the saphenous vein specified the left atrium form the inferior vena cava. Some considerations are made on the surgical methods used for the fourth operation, and in regard of the fact that the patient refused blood transfusion because of religious convictions (Jehova Witness).
Modified repair of mixed anomalous pulmonary venous connection.
van Son, J A; Hambsch, J; Mohr, F W
1998-05-01
A modified repair technique is reported for mixed total or partial anomalous pulmonary venous connection with the right superior pulmonary vein connecting to the superior vena cava, the right inferior pulmonary vein to the right atrium or left atrium, and the left pulmonary veins to the coronary sinus. The superior vena cava is transected above the highest right superior pulmonary vein, its cephalad end is anastomosed to the right atrial appendage, and a pericardial baffle is constructed between the cardiac ostium of the superior vena cava, the ostium of the right inferior pulmonary vein, and the left atrium, including the coronary sinus, which is unroofed. The reported technique may be valuable to avoid pulmonary venous obstruction in complex mixed forms of total or partial anomalous pulmonary venous connection.
Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound
2017-10-01
AWARD NUMBER: W81XWH-15-1-0709 TITLE: Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound PRINCIPAL INVESTIGATOR: Donald...No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for... information . Send comments regarding this burden estimate or any other aspect of this collection of information , including suggestions for reducing this
Nephroblastoma with right atrial extension: preoperative diagnosis and management.
Vaughan, E D; Crosby, I K; Tegtmeyer, C J
1977-04-01
A 14-year-old black boy, with a large nephroblastoma of the right kidney, had preoperative identification of inferior vena cava and right atrial involvement. Renal arteriography revealed linear arterial channels in the anatomic distribution of the inferior vena cava and venography revealed total caval occlusion and a right atrial mass. Radical excision, using a cardiopulmonary bypass, resulted in a 6-month postoperative survival.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goo, Dong Erk, E-mail: degoo@hosp.sch.ac.kr; Kim, Yong Jae; Choi, Deuk Lin
2011-02-15
A 67-year-old woman with end-stage renal disease presented with profound edema of both breasts. The presence of a patent hemodialysis basilic transposition fistula and superior vena cava obstruction (SVC), due to fibrosing mediastinitis, was demonstrated by the use of fistulography. Endovascular treatment with a balloon and stent caused immediate resolution of the breast edema.
Nyakas, Csaba; Felszeghy, Klára; Szabó, Róbert; Keijser, Jan N; Luiten, Paul G M; Szombathelyi, Zsolt; Tihanyi, Károly
2009-01-01
Vinpocetine (ethyl-apovincaminate, Cavinton), a synthetic derivative of the Vinca minor alkaloid vincamine, has been used now for decades for prevention and treatment of cerebrovascular diseases predisposing to development of dementia. Both vinpocetine and its main metabolite cis-apovincaminic acid (cAVA) exert a neuroprotective type of action. Bilateral N-methyl-D-aspartate (NMDA)-induced neurodegeneration in the entorhinal cortex of rat was used as a dementia model to confirm the neuroprotective action of these compounds in vivo. NMDA-lesioned rats were treated 60 min before lesion and throughout 3 postoperative days with a 10 mg/kg intraperitoneal dose of vinpocetine or cAVA. Behavioral tests started after termination of drug treatment and consisted of novel object recognition, social discrimination, and spontaneous alternation in a Y-maze, and spatial learning in the Morris water maze. At the end of behavioral testing brains were perfused with fixative and the size of the excitotoxic neuronal lesion and that of microglial activation around the lesion were assayed quantitatively on brain sections immunostained for neuron-specific nuclear protein (NeuN) and integrin CD11b, respectively. Entorhinal NMDA lesions impaired recognition of novel objects and the new social partner, and suppressed spontaneous alternation and spatial learning performance in the Morris maze. Both vinpocetine and cAVA effectively attenuated the behavioral deficits, and significantly decreased lesion size and the region of microglia activation. Both lesion-induced attention deficit and learning disabilities were markedly alleviated by vinpocetine and cAVA. The morphological findings corroborated the behavioral observations and indicated reduced lesion size and microglia activation especially after vinpocetine treatment which supports an in vivo neuroprotective mode of action of vinpocitine and a less potent action of cAVA.
ENDO, Natsumi; NAGAI, Kiyosuke; TANAKA, Tomomi; KAMOMAE, Hideo
2012-01-01
Abstract The present study was designed to assess progesterone profiles at the secreted (caudal vena cava) and circulating levels (jugular vein) and luteinizing hormone (LH) secretion pattern in lactating and non-lactating cows with reference to feeding. Four lactating and four non-lactating cycling Holstein cows were examined. Blood samples were collected simultaneously from the caudal vena cava (via a catheter inserted from the coccygeal vein) and the jugular vein every 15 min for 12 h (0500–1700 h) during the functional luteal phase. Cows were fed 50% of the daily diet 6 h after the start of blood sampling. During the 12-h sampling period, mean progesterone concentrations in the caudal vena cava did not differ between lactating and non-lactating cows (49.0 ± 2.9 and 53.3 ± 3.7 ng/ml; mean ± SE), whereas mean progesterone concentrations in the jugular vein in lactating cows were higher than those in non-lactating cows (6.4 ± 0.1 and 5.6 ± 0.1 ng/ml, P < 0.001). Lactating cows had a higher frequency of LH pulses than non-lactating cows (7.0 ± 0.7 and 4.3 ± 0.9 pulses/12 h, P<0.05). The influence of feeding was not observed on LH profiles but was observed on progesterone profiles in both veins. Progesterone concentrations in the caudal vena cava increased after feeding in both groups. Progesterone concentrations in the jugular vein decreased after feeding in lactating cows but not in non-lactating cows. These results indicate the difference in feeding-related changes in progesterone dynamics between lactating and non-lactating cows. PMID:23171608
A case of residual inferior sinus venosus defect after ineffective surgical closure.
Uga, Sayuri; Hidaka, Takayuki; Takasaki, Taiichi; Kihara, Yasuki
2014-10-03
A 38-year-old woman presented with cyanosis and heart failure 34 years after patch closure of an atrial septal defect and partial anomalous pulmonary venous connection. CT and cardiac catheterisation showed a residual defect that caused right-to-left shunting. The patch almost blocked the inferior vena cava from the right atrium, resulting in uncommon drainage of the inferior vena cava into the left atrium. Other anomalies included the coronary-to-pulmonary artery fistula and duplicate inferior vena cava with dilated azygos venous system. A second surgery was performed, and we confirmed an inferior sinus venosus defect, which is rare and can be misdiagnosed. The ineffective patch closure had caused a haemodynamic status that rarely occurs. We describe the diagnostic process and emphasise the importance of correctly understanding the entity. 2014 BMJ Publishing Group Ltd.
Meandering Right Pulmonary Vein to the Left Atrium and Inferior Vena Cava
Tortoriello, Tia A.; Vick, G. Wesley; Chung, Taylor; Bezold, Louis I.; Vincent, Julie A.
2002-01-01
We report a case of a healthy, asymptomatic 6-year-old boy in whom an anomalous right pulmonary vein was noted to drain into both the inferior vena cava and left atrium in association with findings consistent with scimitar syndrome. The anomalous pulmonary vein took a very circuitous route through the lungs before draining into the left atrium, a condition previously termed “meandering pulmonary vein.” To aid in the diagnosis, cardiovascular magnetic resonance imaging and magnetic resonance angiography were used to delineate this complex course and the connection of the anomalous pulmonary vein. To our knowledge, this is the 1st reported case of a meandering pulmonary vein with dual drainage to the inferior vena cava and left atrium in association with other anomalies. (Tex Heart Inst J 2002;29:319–23) PMID:12484618
Guijarro Escribano, J F; Antón, R F; Colmenarejo Rubio, A; Sáenz Cascos, L; Sainz González, F; Alguacil Rodríguez, R
2007-03-01
Recently, there has been an increase in the number of cases of superior vena cava (SVC) syndrome associated with chronic indwelling central venous catheters. Fibrinolytic therapy and endovascular treatment are currently achieving good results. We present a case history of a patient with SVC with a catheter used for chemotherapy, which was successfully treated with catheter-directed (intraclot) infusion thrombolytic therapy with urokinase.
Blood Oxygen Conservation in Diving Sea Lions: How Low Does Oxygen Really Go
2015-09-30
5 6 7 0 20 40 60 80 100 % H b Sa tu ra tio n (S O2 ) Time into Dive (min) Arterial SO2 PostVenaCava SO2 AntVenaCava SO2 3 Figure 2. Rate of...change in posterior venacaval hemoglobin saturation ( SO2 ) in relation to stroke rate during descent, bottom phase, and ascent of all dives of sea
Cardiac Metastasis from Invasive Thymoma Via the Superior Vena Cava: Cardiac MRI Findings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dursun, Memduh, E-mail: memduhdursun@yahoo.com; Sarvar, Sadik; Cekrezi, Bledi
2008-07-15
Cardiac tumors are rare, and metastatic deposits are more common than primary cardiac tumors. We present cardiac magnetic resonance imaging (MRI) findings of a 50-year-old woman with invasive thymoma. Cardiac MRI revealed a heterogeneous, lobulated anterior mediastinal mass invading the superior vena cava and extending to the right atrium. In cine images there was no invasion to the right atrial wall.
Venous outflow obstruction and portopulmonary hypertension after orthotopic liver transplantation
Aguirre-Avalos, Guadalupe; Covarrubias-Velasco, Marco Antonio; Rojas-Sánchez, Antonio Gerardo
2013-01-01
Patient: Female, 54 Final Diagnosis: Suprahepatic inferior vena cava anastomosis stricture Symptoms: Ascites • fatigue • lower limb edema • hepatomegaly Medication: — Clinical Procedure: — Specialty: Transplantology • Critical Care Medicine Objective: Unusual clinical course Background: Suprahepatic inferior vena cava anastomosis stricture is an unusual vascular complication after orthotopic liver transplantation with the “piggyback” technique. Clinical manifestations are dependent upon the severity of the stenosis. Portopulmonary hypertension after orthotopic liver transplantation is a complication that carries high mortality due to cardiopulmonary dysfunction. The pathogenesis of pulmonary vascular disorders after orthotopic liver transplantation remains uncertain. Case Report: We report a case of acute right heart pressure overload after surgical correction of the suprahepatic inferior vena cava anastomotic stricture in a 54-year-old woman who had preexisting pulmonary arterial hypertension associated with portal hypertension after orthotopic liver transplantation. Twenty months posttransplantation, she developed fatigue and progressive ascites. On admission, the patient had hepatomegaly, ascites, and lower limb edema. Symptoms in the patient developed gradually over time. Conclusions: Recurrent portal hypertension by vascular complications is a cause of pulmonary arterial hypertension after orthotopic liver transplantation. Clinical manifestations of suprahepatic inferior vena cava anastomotic stenosis are dependent upon their severity. Sildenafil is an effective drug for treatment of pulmonary arterial hyper-tension after portal hypertension by vascular complications. PMID:24046802
Karahan, Oguz; Kutas, H Barıs; Gurbuz, Orcun; Tezcan, Orhan; Caliskan, Ahmet; Yavuz, Celal; Demirtas, Sinan; Mavitas, Binali
2016-10-01
Deep venous thrombosis (DVT) is a life-threatening and morbid pathology. This study aimed to investigate the efficacy of an early thrombolysis procedure using a rotator thrombolysis device. Sixty-seven patients with acute proximal DVT were enrolled in the study. Patients' data were recorded retrospectively. Initially, an infrarenal retrievable vena cava filter was placed through the femoral vein. Then, a rotator thrombolysis device and a thrombolytic agent injection were applied to the occluded segments of the deep veins by puncturing the popliteal vein. The identified reasons were trauma (43.3%), pregnancy (20.9%), undiagnosed (11.9%), major surgical operation (10.5%), immobilization (7.5%), and malignancy (5.9%). Immediate total recanalization was conducted in all patients, and the leg diameters returned to normal ranges in the early postoperative period. Hospital mortality or severe complications were not detected. New thrombolytic devices seem to reduce in-hospital mortality risks and may potentially decrease post-thrombotic morbidity. © The Author(s) 2015.
Guo, Zhe; He, Wei; Hou, Jing; Li, Tong; Zhou, Hua; Xu, Yuan; Xi, Xiuming
2014-09-01
To approach the evaluative effect of respiratory variation of superior vena cava peak flow velocity measured using transthoracic echocardiography (TTE) on fluid responsiveness in patients with mechanical ventilation. A prospective cohort study was conducted. All mechanical ventilated critically ill patients whose fluid therapy was planned due to hypovolemia in Department of Critical Care Medicine of Beijing Tongren Hospital of Capital Medical University from April 2011 to April 2013 were enrolled. Volume expansion was performed with 500 mL Linger solution within 30 minutes. Patients were classified as responders if pulse pressure variation (PPV) increased ≥ 13% before volume expansion. The respiratory variation in superior vena cava peak velocity was calculated as the difference between maximum and minimum values of velocity in peak A, peak S and peak D over a single respiratory circle, and their variations (ΔA, ΔS, ΔD) were also calculated. The receiver operating characteristic curve (ROC curve) was plotted to assess the evaluative effect of respiratory variation of superior vena cava peak velocity on fluid responsiveness. Twenty-seven patients were enrolled in this study. Volume expansion increased PPV ≥ 13% happened in 14 patients (responders). The velocity of superior vena cava in peak A, peak S, peak D was significantly increased after volume expansion compared with that before volume expansion in responders [peak A (cm/s): 34.6 ± 2.2 vs. 31.3 ± 2.1, t=-2.493, P=0.027; peak S (cm/s): 39.1 ± 1.3 vs. 35.3 ± 2.1, t=-2.564, P=0.024; peak D (cm/s): 28.1 ± 1.2 vs. 23.3 ± 1.4, t=-4.995, P=0.000], but there was no significant difference in ΔA, ΔS and ΔD between before and after volume expansion. The ΔA, ΔS and ΔD were positively correlated with PPV (r=0.040, P=0.854; r=0.350, P=0.074; r=0.749, P=0.000). The area under ROC curve (AUC) of peak S was 0.36 [95% confidence interval (95%CI): 0.11-0.52], but the AUC of ΔS was 0.68 (95%CI 0.47-0.89), the AUC of peak D was 0.41 (95%CI 0.19-0.63), but the AUC of ΔD was 0.95 (95%CI 0.86-1.00), so the aberration rate of superior vena cava in respiration was better than the flow rate in superior vena cava. When the cut-off value of ΔS was 20.7% for predicting fluid responsiveness, the sensitivity was 78.6% and the specificity was 61.5%. When the cut-off value of ΔD was 12.7% for predicting fluid responsiveness, the sensitivity was 92.0% and the specificity was 92.3%. Respiratory variations in superior vena cava peak velocity measured by TTE could assess fluid responsiveness in patients with mechanical ventilation.
Rodrigues, A F; van Mourik, I D M; Sharif, K; Barron, D J; de Giovanni, J V; Bennett, J; Bromley, P; Protheroe, S; John, P; de Ville de Goyet, J; Beath, S V
2006-04-01
The 3-year survival after small bowel transplantation (SBTx) has improved to between 73% and 88%. Impaired venous access for parenteral nutrition can be an indication for SBTx in children with chronic intestinal failure. To report our experience in management of children with extreme end-stage venous access. The study consisted of 6 children (all boys), median age of assessment 27 months (range, 13-52 months), diagnosed with total intestinal aganglionosis (1), protracted diarrhea (1), and short bowel syndrome (4), of which gastroschisis (2) and malrotation with midgut volvulus (2) were the causes. All had a documented history of more than 10 central venous catheter insertions previously. All had venograms, and 1 child additionally had a magnetic resonance angiogram to evaluate venous access. Five of 6 presented with thrombosis of the superior vena cava (SVC) and/or inferior vena cava. Venous access was reestablished as follows: transhepatic venous catheters (5), direct intra-atrial catheter via midline sternotomy (4), azygous venous catheters (2), dilatation of left subclavian vein after passage of a guide wire and then placing a catheter to reach the right atrium (1), radiological recanalization of the SVC and placement of a central venous catheter in situ (1), and direct puncture of SVC stump(1). Complications included serous pleural effusion after direct intra-atrial line insertion, which resolved after chest drain insertion (1), displacement of transhepatic catheter needing repositioning (2), and SVC stent narrowing requiring repeated balloon dilatation. Four children with permanent intestinal failure on assessment were offered SBTx, 3 of which were transplanted and were established on full enteral nutrition; the family of 1 child declined the procedure. In the remaining 2 children in whom bowel adaptation was still a possibility, attempts were made to provide adequate central venous access as feeds and drug manipulations were undertaken. One of them received liver and SBTx nearly 3 years after presenting with end-stage central venous access, because attempts to achieve independence from parenteral nutrition had failed. The other child died immediately after a transhepatic venous catheter placement, possibly from a nutritional depletion syndrome as no physical cause of death was found. Direct intra-atrial catheters in transplanted children proved to be adequate for the management of uncomplicated transplantation, although the usual infusion protocol had to be modified considerably, and the lack of access would have been critical if massive blood transfusion had been required during the transplant procedure. It was possible to reestablish central venous access in all cases. However, this was time consuming and difficult to assemble a skilled team consisting of one of more: surgeon, cardiologist, interventional radiologist, and transplant anesthetist. Small bowel transplantation is easier and safer with adequate central venous access, and we advocate liaison with an SBTx center at an early stage.
Characterization and Utilization of Opiate-Like Hibernation Factors.
1993-12-08
duodenum, and both kidneys were dissected free, along with the abdominal aorta and the inferior vena cava . The chest was then opened, and the heart, and...lungs along with the aorta and the superior and inferior vena cava (IVC), were dissected free. The trachea was transected and an endotracheal tube was...pericardial incision was extended inferiorly, exposing the anterior aspect of the left atrium and the left -Page 36 - inferior pulmonary vein. The
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Robert M.; David, Elizabeth; Pugash, Robyn A.
Fibrotic central venous occlusions in patients with thoracic malignancy and prior radiotherapy can be impassable with standard catheters and wires, including the trailing or stiff end of a hydrophilic wire. We report two patients with superior vena cava syndrome in whom we successfully utilized a radiofrequency guide wire (PowerWire, Baylis Medical, Montreal, Quebec, Canada) to perforate through the occlusion and recanalize the occluded segment to alleviate symptoms.
Masi, Marco; Moeini, Seyed Arash; Boari, Angela; Cimmino, Alessio; Vurro, Maurizio; Evidente, Antonio
2018-07-01
Cavoxin is a tetrasubstituted phytotoxic chalcone and cavoxone is the corresponding chroman-4-one, both produced in vitro by Phoma cava, a fungus isolated from chestnut. Cavoxin showed biofungicide potential against fungal species responsible for food moulding. Therefore, cavoxin has potential to be incorporated into biopolymer to generate 'intelligent food packaging'. To reach this objective, large-scale production of cavoxin by P. cava fermentation needs to be optimized. A rapid and efficient method for cavoxin analysis, as well as of cavoxone, in the fungal culture filtrates and the corresponding organic extracts is the first experimental step. Thus, a HPLC method was developed and applied to quantify cavoxin and cavoxone production in two different fungal culture conditions. The analysis proved that cavoxin production in stirred culture filtrates is significantly higher than in static ones.
Situs ambiguous in a schoolchild
Tortajada, Miguel; Moreno, Miriam; Gracia, Miguel; Sanchis, Amparo
2010-01-01
We report the case of a 9-year-old child with asthma, atopic dermatitis and allergic rhinoconjunctivitis due to house dust mites, in whom a routine chest x-ray identified by chance abnormal organ position, such as the stomach located on the right side. Abdominal ultrasonography indicated a centralised liver, with polysplenia on the right side and an inferior cava vein located to the left of the aorta with no interruption. Ultrasonography did not show heart defects. Magnetic resonance imaging (MRI) of the abdomen was performed that showed a short pancreas, with no neck, body and tail in it, and a left inferior vena cava with normal outlet of the renal veins, and absence of the intrahepatic part of the inferior vena cava, that was replaced by the left hemiazygos vein. Spinal cord MRI revealed dorsal syringomelia. In view of the results obtained, the diagnosis of situs ambiguous was established. PMID:22121394
Jain, Ankur
2014-01-01
We report a case of a 60-year-old lady who presented with bilateral lower limb swelling and a thyroid swelling with clinical features consistent with thyrotoxicosis. Investigations revealed the presence of a thrombus in bilateral external, internal iliac veins, and inferior vena cava extending up to its infrahepatic part. Hormone profile and radioiodine uptake scan confirmed the diagnosis of Graves’ disease. Further workup revealed the presence of antiphospholipid antibodies (confirmed after a repeat test at 12 weeks). The patient was treated with antithyroid drugs and anticoagulants. The patient improved with normalization of thyroid function and partial recanalization of the infrahepatic part of inferior vena cava. Hyperthyroidism has been implicated as a potential hypercoagulable state; however, the association of Graves’ disease with antiphospholipid antibody syndrome is limited to isolated case reports. This case highlights a new mechanism underlying hypercoagulability associated with Graves’ disease. PMID:24812529
Persistent left superior vena cava
Tyrak, Kamil W; Hołda, Mateusz K; Koziej, Mateusz; Piątek, Katarzyna; Klimek-Piotrowska, Wiesława
2017-01-01
Summary Persistent left superior vena cava (PLSVC) is the most common congenital malformation of thoracic venous return and is present in 0.3 to 0.5% of individuals in the general population. This heart specimen was dissected from a 35-yearold male cadaver whose cause of death was determined as non-cardiac. The heart was examined and we found a PLSVC draining into the coronary sinus. The right superior vena cava was present with a small-diameter ostium. An anomalous pulmonary vein pattern was observed; there was a common trunk to the left superior and left inferior pulmonary veins (diameter 17.8 mm) and an additional middle right pulmonary vein (diameter 2.7 mm) with two classic right pulmonary veins. The PLSVC draining into the coronary sinus had led to its enlargement, which could have altered the cardiac haemodynamics by significantly reducing the size of the left atrium and impeding its outflow via the mitral valve. PMID:28759082
Double aortic arch and persistent left vena cava in a white lion cub (Panthera leo).
Goldin, J P; Lambrechts, N E
1999-03-01
A 4-mo-old female white lion (Panthera leo) cub was presented with a 2-wk history of persistent postprandial regurgitation, mild dyspnea, and poor weight gain. The cub was weak and thin but otherwise alert. Survey and contrast radiography revealed a large dilated esophagus cranial to the heart base, with an esophageal filling defect present at the level of the fourth thoracic vertebra. A vascular ring anomaly was tentatively diagnosed. Exploratory thoracotomy revealed a double aortic arch and a persistent left vena cava. The left aortic arch was ligated and divided, and recovery was uneventful. A single episode of regurgitation occurred within the first postoperative month, and the cub gained 5.5 kg in weight during the same time period. Neither double aortic arch nor persistent left vena cava has been reported in a nondomestic felid.
[Surgical treatment of partial anomalous pulmonary venous drainage].
Cabrera, A; Idígoras, G; Sarrionandía, M J; Martínez, P; Rumoroso, J R; Alcíbar, J
1996-02-01
We studied all patients operated for partial anomalous pulmonary venous drainage and half-time follow-up. Twenty-eight patients with a mean age of 5 +/- 5 years (5 patients were less than 1 year old). There were sixteen male and twelve female patients. Thirteen patients were symptomatic (47%). The drainage was to the superior vena cava in thirteen cases, to the inferior vena cava in eight cases, to the right atrium in five cases, mixed (to the superior vena cava and to the inferior vena cava) in one case and to the innominate vein in one patient. The diagnosis was made through echocardiography and catheterization in 25 patients, whereas nuclear magnetic resonance was performed in the last five patients. All cases were corrected through medium thoracotomy, except for the single case in which the drainage was to the innominate vein). In 27 patients, the pulmonary veins were guided to the left atrium through an enlarged present atrial septal defect or through a created atrial septal defect. In one case a direct connection was performed from the veins to the left atrium. After the surgical correction, all patients underwent a color-coded Doppler echocardiography study and a nuclear magnetic resonance study was performed in five patients. Twenty-seven patients survived after surgical correction. The patient with a mixed drainage developed an obstruction of the superior vena cava, the pressure gradient was 9 mmHg. He required a second surgical procedure followed with angioplasty on two occasions during a six month period. Two patients showed an ectopic atrial rhythm at some late time. The patient who died was one month old and had an associated pulmonary parenchymal sequestration. Partial anomalous venous connection is a congenital heart disease which has an easy surgical correction. Complications may arise after the surgical correction, among them obstruction of the superior vena cava and arrythmias are most frequently found. Obstruction is present when 50% of the caval area is occupied by the patch. The arrythmias occur following all surgical techniques. In order to decrease the arrythmias it is necessary to perform a good hemosthasis at the site of the patch, to leave the sinus node free of compression and to perform the atrial incision at the posterior wall. The diagnosis and the follow-up can be performed with non-invasive procedures.
[Value of x-ray computed tomography in the study of the inferior vena cava in urologic practice].
Barré, C; Vialle, M; Rieux, D; Caron-Poitreau, C; Soret, J Y; Rognon, M
1985-01-01
The CT scan provides a reliable evaluation of the inferior vena cava, especially since the development of second and third generation scanners. It can readily detect congenital malformations and obstructive anomalies complicating renal cancer and it is also able to determine the tumoral or thrombotic nature of the venous obstruction. This excellent definition of the vessel reduces the indications for caval angiography to a few exceptional cases.
Cardiac Pressure Changes with Venous Gas Embolism and Decompression
1994-04-01
inferior vena cava via the left femoral vein for venous access. Airway pressure was measured from a connector at the proximal end of the endotracheal...Hartley), mount- ed in a 7-9 m acrylic cuff was surgically placed around the inferior vena cava via laparotomy, approximately 1-2 cm above the renal...pressure and decreasing cardiac output which in return may cause the left atrial pressure to fall below that of the right atrium . Recent studies have
Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact
2001-03-01
inferior vena cava to the right auricle. From the right auricle, the blood is passed into the right ventricle. The right ventricle pumps the blood...the rib and vertebrae is modeled with two beam elements. To create the subcoastal angle, vertical cartilaginous connections at the inferior edge of...brachiocephalic aorta, the aorta, pulmonary arteries and veins, internal jugular veins, brachial veins, and superior vena cava . These vessels are modeled
Permanent right ventricular pacing through an anomalous left superior vena cava.
Amikam, S; Lemer, J; Riss, E
1977-01-01
A persistent left superior vena cava can complicate the implantation of a transvenous pacemaker. In a patient who required a permanent pacemaker, this venous anomaly was discovered during the insertion of the electrode but it did not prevent long-term right ventricular pacing. This was achieved after the electrode had been manipulated through the coronary sinus and right atrium. A plan of management is proposed for dealing with this unexpected problem. Images PMID:601745
Morphology of congenital portosystemic shunts involving the right gastric vein in dogs.
White, R N; Parry, A T
2015-07-01
To describe the anatomy of congenital portosystemic shunts involving the right gastric vein in dogs. Retrospective review of a consecutive series of dogs managed for congenital portosystemic shunt. Twenty-two dogs met the inclusion criteria of a congenital portosystemic shunt involving the right gastric vein with recorded intraoperative mesenteric portovenography or computed tomography angiography and gross observations at the time of surgery. Of these, 20 (91%) had a shunt that entered the pre-hepatic caudal vena cava at the level of the epiploic foramen and two (9%) had a shunt that entered the post-hepatic caudal vena cava at the level of the diaphragm. Shunts entering the pre-hepatic caudal vena cava could be further classified into three consistent subdivisions. The morphology of each shunt type described appeared to be a result of an abnormal communication between the left gastric vein and the caudal vena cava, the presence or absence of an abnormal communication between the splenic, left gastric and portal veins and the subsequent development of preferential blood flow through essentially normal portal vessels within the portal venous system. The abnormal communication (shunt) was through the left gastric vein and not the right gastric vein, as might have been expected. This information may help with surgical planning in cases undergoing shunt closure surgery. © 2015 British Small Animal Veterinary Association.
Chandra, Dinesh; Gupta, Anubhav; Nath, Ranjit K.; kazmi, Aamir; Grover, Vijay; Gupta, Vijay K.
2013-01-01
Background The anatomical variability in patients with anomalous pulmonary venous connection to superior vena cava presents a surgical challenge. The problem is further compounded by the common occurrence of postoperative complications like arrhythmias and obstruction of the superior vena cava or pulmonary veins. We present our experience of managing this subset using the two patch and Warden's techniques. Patients and methods Between June 2011 and September 2012, 7 patients with APVC to the SVC were operated in our institute. After delineating the anatomy, five of them had a two patch repair and two were managed with Warden's technique. Results There was no in-hospital mortality or early mortality over a mean follow-up of 9.66 ± 3.88 months (range 6–15 months). All the patients on follow-up had unobstructed pulmonary venous and SVC drainage on echocardiography and all of them were in normal sinus rhythm. Conclusions Anomalous pulmonary venous connection to superior vena cava is a challenging subset of patients in whom the surgical management needs to be individualized. The detailed anatomy must be delineated using echocardiography with or without CT angiography before deciding the surgical plan. This entity can be repaired with excellent immediate and early results. However, these patients must be closely followed up for complications like systemic and pulmonary venous obstruction and sinus node dysfunction. PMID:24206880
[Medical image segmentation based on the minimum variation snake model].
Zhou, Changxiong; Yu, Shenglin
2007-02-01
It is difficult for traditional parametric active contour (Snake) model to deal with automatic segmentation of weak edge medical image. After analyzing snake and geometric active contour model, a minimum variation snake model was proposed and successfully applied to weak edge medical image segmentation. This proposed model replaces constant force in the balloon snake model by variable force incorporating foreground and background two regions information. It drives curve to evolve with the criterion of the minimum variation of foreground and background two regions. Experiments and results have proved that the proposed model is robust to initial contours placements and can segment weak edge medical image automatically. Besides, the testing for segmentation on the noise medical image filtered by curvature flow filter, which preserves edge features, shows a significant effect.
Human Engineering Design Criteria for Modern Control/Display Components and Standard Parts.
1980-05-01
to identify changes required to achieve the stated program objectives. The effort concentrated or the following factors: " Type and degree of change...greatest viewing angle) other than that actually forming the image ( nonimage brightness); i.e., I BR = n Contrast - The difference in brightness between...placement of the scope relative to the light source, through the use of a hood or shield; by optical coatings or filters over the light source; or by
Stimulus and recording variables and their effects on mammalian vestibular evoked potentials
NASA Technical Reports Server (NTRS)
Jones, Sherri M.; Subramanian, Geetha; Avniel, Wilma; Guo, Yuqing; Burkard, Robert F.; Jones, Timothy A.
2002-01-01
Linear vestibular evoked potentials (VsEPs) measure the collective neural activity of the gravity receptor organs in the inner ear that respond to linear acceleration transients. The present study examined the effects of electrode placement, analog filtering, stimulus polarity and stimulus rate on linear VsEP thresholds, latencies and amplitudes recorded from mice. Two electrode-recording montages were evaluated, rostral (forebrain) to 'mastoid' and caudal (cerebellum) to 'mastoid'. VsEP thresholds and peak latencies were identical between the two recording sites; however, peak amplitudes were larger for the caudal recording montage. VsEPs were also affected by filtering. Results suggest optimum high pass filter cutoff at 100-300 Hz, and low pass filter cutoff at 10,000 Hz. To evaluate stimulus rate, linear jerk pulses were presented at 9.2, 16, 25, 40 and 80 Hz. At 80 Hz, mean latencies were longer (0.350-0.450 ms) and mean amplitudes reduced (0.8-1.8 microV) for all response peaks. In 50% of animals, late peaks (P3, N3) disappeared at 80 Hz. The results offer options for VsEP recording protocols. Copyright 2002 Elsevier Science B.V.
Thakali, Keshari; Galligan, James J; Fink, Gregory D; Gariepy, Cheryl E; Watts, Stephanie W
2008-07-01
Heterodimerization of G-protein coupled receptors can alter receptor pharmacology. ET A and ET B receptors heterodimerize when co-expressed in heterologous expression lines. We hypothesized that ET A and ET B receptors heterodimerize and pharmacologically interact in vena cava from wild-type (WT) but not ET B receptor deficient (sl/sl) rats. Pharmacological endothelin receptor interaction was assessed by comparing ET-1-induced contraction in rings of rat thoracic aorta and thoracic vena cava from male Sprague Dawley rats under control conditions, ET A receptor blockade (atrasentan, 10 nM), ET B receptor blockade (BQ-788, 100 nM) or ET B receptor desensitization (Sarafotoxin 6c, 100 nM) and ET A plus ET B receptor blockade or ET A receptor blockade plus ET B receptor desensitization. In addition, similar pharmacological ET receptor antagonism experiments were performed in rat thoracic aorta and vena cava from WT and sl/sl rats. ET A but not ET B receptor blockade or ET B receptor desensitization inhibited aortic and venous ET-1-induced contraction. In vena cava but not aorta, when ET B receptors were blocked (BQ-788, 100 nM) or desensitized (S6c, 100 nM), atrasentan caused a greater inhibition of ET-1-induced contraction. Vena cava from WT but not sl/sl rats exhibited similar pharmacological ET receptor interaction. Immunocytochemistry was performed on freshly dissociated aortic and venous vascular smooth muscle cells to determine localization of ET A and ET B receptors. ET A and ET B receptors qualitatively co-localized more strongly to the plasma membrane of aortic compared to venous vascular smooth muscle cells. Our data suggest that pharmacological ET A and ET B receptor interaction may be dependent on the presence of functional ET B receptors and independent of receptor location.
Patterns of anomalous pulmonary venous drainage.
Snellen, H A; van Ingen, H C; Hoefsmit, E C
1968-07-01
All of our cases of abnormal pulmonary venous connections collected to the middle of 1965 and verified at surgery or autopsy have been reviewed by means of diagrams and tabulations, using a specially devised code to facilitate the survey. The material consisted of 52 autopsy cases (half of them obtained after surgery) and the cases of 72 patients who survived operation. The postmortem group was much younger than the surgical group and differed also from the latter by showing male preponderance as well as relatively many instances of total abnormal pulmonary venous connection and frequently associated cardiac anomalies. Partial anomalous connection of right pulmonary veins was 10 times more frequent than that of the left pulmonary veins. This was caused by (1) the frequent drainage of some of the right pulmonary veins into the junctional area between right atrium and superior vena cava in the presence of normal left pulmonary veins, and (2) the complete absence of isolated left pulmonary venous connection to the right atrium. Abnormal connection of solitary pulmonary veins was always effected to the most proximal venous structure among the four possible ones which are derived from the main embryonic channels (superior vena cava and inferior vena cava on the right side, and left superior vena cava and coronary sinus on the left side). Common pulmonary veins from one lung also drained in accordance with this proximity rule, if this may be taken to apply also to the drainage of right pulmonary veins into the right atrium. The one exception in our material was the drainage of all right pulmonary veins into the portal venous system. Total abnormal pulmonary venous connection may be found with all structures mentioned, but most frequently with the left superior vena cava, or coronary sinus, or both, usually by way of a common pulmonary vein. In a few cases however, drainage into different sites, all of them abnormal, did occur. Then again the proximity rule seemed to apply. A tentative embryological explanation is given for the patterns described.
Lu, Hou Tee; Chong, Jen Lim; Othman, Norliza; Vendargon, Simon; Omar, Shamsuddin
2016-05-03
Renal cell carcinoma is a potentially lethal cancer with aggressive behavior and it tends to metastasize. Renal cell carcinoma involves the inferior vena cava in approximately 15% of cases and it rarely extends into the right atrium. A majority of renal cell carcinoma are detected as incidental findings on imaging studies obtained for unrelated reasons. At presentation, nearly 25% of patients either have distant metastases or significant local-regional disease with no symptoms that can be attributed to renal cell carcinoma. A 64-year-old Indian male with a past history of coronary artery bypass graft surgery, congestive heart failure, and diabetes mellitus complained of worsening shortness of breath for 2 weeks. Incidentally, a transthoracic echocardiography showed a "thumb-like" mass in his right atrium extending into his right ventricle through the tricuspid valve with each systole. Abdomen magnetic resonance imaging revealed a heterogenous lobulated mass in the upper and mid-pole of his right kidney with a tumor extending into his inferior vena cava and right atrium, consistent with our diagnosis of advanced renal cell carcinoma which was later confirmed by surgical excision and histology. Radical right nephrectomy, lymph nodes clearance, inferior vena cava cavatomy, and complete tumor thrombectomy were performed successfully. Perioperatively, he did not require cardiopulmonary bypass or deep hypothermic circulatory arrest. He had no recurrence during the follow-up period for more than 2 years after surgery. Advanced extension of renal cell carcinoma can occur with no apparent symptoms and be detected incidentally. In rare circumstances, atypical presentation of renal cell carcinoma should be considered in a patient presenting with right atrial mass detected by echocardiography. Renal cell carcinoma with inferior vena cava and right atrium extension is a complex surgical challenge, but excellent results can be obtained with proper patient selection, meticulous surgical techniques, and close perioperative patient care.
Outbreak of giardiasis associated with a community drinking-water source.
Daly, E R; Roy, S J; Blaney, D D; Manning, J S; Hill, V R; Xiao, L; Stull, J W
2010-04-01
Giardiasis is a common waterborne gastrointestinal illness. In 2007, a community giardiasis outbreak occurred in New Hampshire, USA. We conducted a cohort study to identify risk factors for giardiasis, and stool and environmental samples were analysed. Consuming tap water was significantly associated with illness (risk ratio 4.7, 95% confidence interval 1.5-14.4). Drinking-water samples were coliform-contaminated and a suspect Giardia cyst was identified in a home water filter. One well was coliform-contaminated, and testing indicated that it was potentially under the influence of surface water. The well was located 12.5 m from a Giardia-contaminated brook, although the genotype differed from clinical specimens. Local water regulations require well placement at least 15 m from surface water. This outbreak, which caused illness in 31 persons, represents the largest community drinking-water-associated giardiasis outbreak in the USA in 10 years. Adherence to well placement regulations might have prevented this outbreak.
Piezoceramic Actuator Placement for Acoustic Control of Panels
NASA Technical Reports Server (NTRS)
Bevan, Jeffrey S.; Turner, Travis L. (Technical Monitor)
2001-01-01
Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibits enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.
Piezoceramic Actuator Placement for Acoustic Control of Panels
NASA Technical Reports Server (NTRS)
Bevan, Jeffrey S.
2000-01-01
Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibit enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.
Ding, Xue-Yan; Chen, Feng; Zhao, Xian-Xian; Wu, Hong; Chen, Shao-Ping; Qin, Yong-Wen
2011-01-01
A 19-year-old male patient presented cyanosis and dyspnoea because of the presence of multiple pulmonary arteriovenous fistulas resulting in oxygen desaturation. The CTA revealed that intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. This is the first reported case of hepatopulmonary syndrome caused by congenital extrahepatic portosystemic shunt in which intestinal and splenic venous blood bypasses the liver and drains into the inferior vena cava. PMID:22937464
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taneja, Manish; Lath, Narayan, E-mail: lath_narayan@yahoo.com; Soo, Tan Bien
Fistulous communication between the renal artery stump and inferior vena cava following nephrectomy is rare. We describe the case of a 52-year-old man with a fistula detected on investigation for hemolytic anemia in the postoperative period. The patient had had a nephrectomy performed 2 weeks prior to presentation for blunt abdominal trauma. The fistula was successfully occluded percutaneously using an Amplatzer vascular plug. The patient recovered completely and was discharged 2 weeks later.
1987-10-01
demonstrated that endotoxin shock is associated with a decrease in compliance of the superior and inferior vena cavae and probably £ Abstracts 17 central...site of a burn wound. METHODS: Anesthetized 350 gram male Long Evans rats were prepared by intrarenal inferior vena cava (IVC) ligation. The rats...elastase has been investigated in the superior vena caval and left atrium blood collected from 167 patients who underwent open heart surgery. The effect
1988-01-01
were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali
Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.
Comparison of Covered Versus Uncovered Stents for Benign Superior Vena Cava (SVC) Obstruction.
Haddad, Mustafa M; Simmons, Benjamin; McPhail, Ian R; Kalra, Manju; Neisen, Melissa J; Johnson, Matthew P; Stockland, Andrew H; Andrews, James C; Misra, Sanjay; Bjarnason, Haraldur
2018-05-01
To identify whether long-term symptom relief and stent patency vary with the use of covered versus uncovered stents for the treatment of benign SVC obstruction. We retrospectively identified all patients with benign SVC syndrome treated to stent placement between January 2003 and December 2015 (n = 59). Only cases with both clinical and imaging follow-up were included (n = 47). In 33 (70%) of the patients, the obstruction was due to a central line or pacemaker wires, and in 14 (30%), the cause was fibrosing mediastinitis. Covered stents were placed in 17 (36%) of the patients, and 30 (64%) patients had an uncovered stent. Clinical and treatment outcomes, complications, and the percent stenosis of each stent were evaluated. Technical success was achieved in all cases at first attempt. Average clinical and imaging follow-up in years was 2.7 (range 0.1-11.1) (covered) and 1.7 (range 0.2-10.5) (uncovered), respectively. There was a significant difference (p = 0.044) in the number of patients who reported a return of symptoms between the covered (5/17 or 29.4%) and uncovered (18/30 or 60%) groups. There was also a significant difference (p = < 0.001) in the mean percent stenosis after stent placement between the covered [17.9% (range 0-100) ± 26.2] and uncovered [48.3% (range 6.8-100) ± 33.5] groups. No significant difference (p = 0.227) was found in the time (days) between the date of the procedure and the date of clinical follow-up where a return of symptoms was reported [covered: 426.6 (range 28-1554) ± 633.9 and uncovered 778.1 (range 23-3851) ± 1066.8]. One patient in the uncovered group had non-endovascular surgical intervention (innominate to right atrial bypass), while none in the covered group required surgical intervention. One major complication (SIR grade C) occurred that consisted of a pericardial hemorrhagic effusion after angioplasty that required covered stent placement. There were no procedure-related deaths. Both covered and uncovered stents can be used for treating benign SVC syndrome. Covered stents, however, may be a more effective option at providing symptom relief and maintaining stent patency if validated by further studies.
Neonatal venous cerebral hemorrhage. Report of two cases.
Misra, Sanjay N; Misra, Ashish K
2003-10-15
Intracranial pathological changes can occur as a result of impaired craniocervical venous return. Thrombosis of central venous access catheters was demonstrated in two neonates born at 38 and 27 weeks' gestation. Neither infant developed hemorrhage of prematurity as confirmed on cranial ultrasonography. Clinical evidence of vena cava thrombosis and associated spontaneous intraventricular hemorrhage developed on Day 24 and 36, respectively, and these findings were confirmed on imaging studies. In one infant the hemorrhage was accompanied by communicating hydrocephalus. The cause of the intracranial disease was attributable to the retrograde cerebral venous congestion. This, together with the primitive venous bed developing in the periventricular region, was associated with the spontaneous hemorrhage in the region of the foramen of Monro. To the authors' knowledge, this is the first report in the English-language literature of spontaneous neonatal intracerebral hemorrhage, due to thrombosis of the superior or inferior vena cava. The natural history of this condition is resolution without sequelae after appropriate therapeutic intervention for the vena cava thrombosis.
Eo, Hyeyoon; Jeon, You-jin; Lee, Myoungsook; Lim, Yunsook
2015-01-14
Obesity is considered to be a metaflammatory condition. Ecklonia cava, brown algae rich in polyphenols, has shown strong antioxidant activity in vitro. This study investigated the effect of E. cava polyphenol extract (ECPE) on the regulation of fat metabolism, inflammation, and the antioxidant defense system in high fat diet-induced obese mice. After obesity was induced by a high-fat diet (HFD), the mice were administered ECPE by gavage for 5 days/12 weeks. ECPE supplementation reduced body weight gain, adipose tissue mass, plasma lipid profiles, hepatic fat deposition, insulin resistance, and the plasma leptin/adiponectin ratio derived from HFD-induced obesity. Moreover, ECPE supplementation selectively ameliorated hepatic protein levels associated with lipogenesis, inflammation, and the antioxidant defense system as well as activation of AMPK and SIRT1. Collectively, ECPE supplement might have potential antiobesity effects via regulation of AMPK and SIRT1 in HFD-induced obesity.
Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave
2015-11-04
We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharifi, Mohsen, E-mail: seyedmohsensharifi@yahoo.com; Bay, Curt; Nowroozi, Sasan
2013-12-15
Purpose: Catheter-directed thrombolysis (CDT) is a highly effective approach in the treatment of deep venous thrombosis (DVT). There are no data on the primary use of CDT with argatroban and tissue plasminogen activator (tPA) in patients without heparin-induced thrombocytopenia (HIT). The aim of this study was to evaluate the efficacy and safety of the combined administration of argatroban and tPA during CDT for massive DVT in patients without HIT. Methods: Thirty-three patients with massive symptomatic iliac and femoropopliteal DVT underwent CDT with tPA and argatroban within 28 {+-} 6 h of presentation. The dose of tPA was 0.75-1 mg/h throughmore » the infusion port and that of argatroban at 0.3-1 {mu}g/kg/min through the side port of the sheath. The patients were evaluated for the efficacy and safety of CDT and recurrent symptomatic venous thromboembolism (VTE) at a mean follow-up of 22 months. Results: There was no bleeding or iatrogenic pulmonary embolism with the CDT regimen we used. Grade III lysis (complete resolution of thrombus on venography) was achieved in 30 patients (91 %). In 3 patients with additional inferior vena cava filter thrombosis, further thrombectomy of the filter was required. No patient developed recurrent VTE. Conclusion: Concomitant administration of argatroban and tPA is a highly safe and effective regimen for CDT for massive DVT.« less
LOFT. Mobile test building (TAN624) is recycled from ANP program ...
LOFT. Mobile test building (TAN-624) is recycled from ANP program for placement before LOFT containment building door. It has not yet been connected to containment building. Note borated water tank at right of dome. Narrow, vertical structure at right of door is shroud is shroud for air exhaust duct. Filter vaults lie between duct shroud and stack. Camera facing westerly. Date: 1974. INEEL negative no. 74-1072 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Adrenal Venous Sampling: Where Is the Aldosterone Disappearing to?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Solar, Miroslav; Ceral, Jiri, E-mail: ceral.jiri@fnhk.c; Krajina, Antonin
Adrenal venous sampling (AVS) is generally considered to be the gold standard in distinguishing unilateral and bilateral aldosterone hypersecretion in primary hyperaldosteronism. However, during AVS, we noticed a considerable variability in aldosterone concentrations among samples thought to have come from the right adrenal glands. Some aldosterone concentrations in these samples were even lower than in samples from the inferior vena cava. We hypothesized that the samples with low aldosterone levels were unintentionally taken not from the right adrenal gland, but from hepatic veins. Therefore, we sought to analyze the impact of unintentional cannulation of hepatic veins on AVS. Thirty consecutivemore » patients referred for AVS were enrolled. Hepatic vein sampling was implemented in our standardized AVS protocol. The data were collected and analyzed prospectively. AVS was successful in 27 patients (90%), and hepatic vein cannulation was successful in all procedures performed. Cortisol concentrations were not significantly different between the hepatic vein and inferior vena cava samples, but aldosterone concentrations from hepatic venous blood (median, 17 pmol/l; range, 40-860 pmol/l) were markedly lower than in samples from the inferior vena cava (median, 860 pmol/l; range, 460-4510 pmol/l). The observed difference was statistically significant (P < 0.001). Aldosterone concentrations in the hepatic veins are significantly lower than in venous blood taken from the inferior vena cava. This finding is important for AVS because hepatic veins can easily be mistaken for adrenal veins as a result of their close anatomic proximity.« less
Yu, C; Liu, Y; Zhu, X; Li, Y; Li, Y
2000-03-01
To compare the hemodynamic effect and energy loss of atrio-ventricular and total cavo-pulmonary connections versus atrio-pulmonary anastomosis for modified Fontan in dogs. Fifteen adult mongrel dogs were divided into three groups. Group I underwent right atrium to right ventricle (using 50% and 25% right ventricular chamber, respectively) connection with the flap of valved homo-pulmonary artery (modified Bjoerk procedure). Group II underwent total cavo-pulmonary connection. Group III received atrio-pulmonary anastomosis. Right atrium pressure, pulmonary artery pressure, and cardiac output were measured by Swan-Ganz catheter. The volumes of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured by electromagnetic flowmeter. The flow-rate of the right pulmonary artery, left pulmonary artery, superior vena cava and inferior vena cava were measured echocardiographically. The fluid energy loss was calculated. The postoperative right atrium pressure in group I was lower than in group III (P < 0.05). The postoperative stroke index in group I and group II was higher than in group III (P < 0.01). The fluid energy loss was decreased when 50% or 25% right ventricle chamber was used (P < 0.01) and the fluid energy less in group II was less than in group III. Our experience suggested that atrio-ventricular connection and total cavo-pulmonary connection would be better than atrio-pulmonary anastomosis for modified Fontan repair of tricuspid valve atresia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fujimori, Masashi, E-mail: fujimorim@clin.medic.mie-u.ac.jp; Yamakado, Koichiro, E-mail: yamakado47@gmail.com; Takaki, Haruyuki, E-mail: takaki-h@clin.medic.mie-u.ac.jp
PurposeTo evaluate long-term results of stent placement retrospectively in patients with outflow block after living-donor-liver transplantation (LDLT).Materials and MethodsFor this institutional review board approved retrospective study conducted during 2002–2012, stents were placed in outflow veins in 15 patients (11.3 %, 15/133) (12 men; 3 female) in whom outflow block developed after LDLT. Their mean age was 52.3 years ± 15.3 (SD) (range, 4–69 years). Venous stenosis with a pressure gradient ≥5 mmHg (outflow block) was observed in the inferior vena cava in seven patients, hepatic vein in seven patients, and both in one patient. Technical success, change in a pressure gradient and clinical manifestations, and complicationsmore » were evaluated. Overall survival of 15 patients undergoing outflow block stenting was compared with that of 116 patients without outflow block after LDLT.ResultsStents were placed across the outflow block veins without complications, lowering the pressure gradient ≤ 3 mmHg in all patients (100 %, 15/15). Clinical manifestations improved in 11 patients (73.3 %, 11/15), and all were discharged from the hospital. However, they did not improve in the other 4 patients (26.7 %, 4/15) who died in the hospital 1.0–3.7 months after stenting (mean, 2.0 ± 1.2 months). No significant difference in 5-year survival rates was found between patients with and without outflow block after LDLT (61.1 vs. 72.2 %, p = .405).ConclusionStenting is a feasible, safe, and useful therapeutic option to resolve outflow block following LDLT, providing equal survival to that of patients without outflow block.« less
Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-03-16
A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.
Lal, Anupam; Acharya, Naveen; Sharma, Varun
2010-01-01
Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.
Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.
Needle versus Tube Thoracostomy in a Swine Model of Traumatic Tension Hemopneumothorax
2009-03-01
jugular vein, through the right atrium , and into the inferior vena cava . Serial digital C-arm chest x-rays allowed mea- surement of the shift from midline...wire in the inferior vena cava 1.34 cm to the right of the spinous processes. B: Insufflation resulted in a mediastinal shift of 2.15 cm to the left of...Received April 26, 2008, from the U.S. Army Institute of Surgical Re- search (JBH, JGM), Fort Sam Houston, Texas; the Naval Medical Cen- ter (STK), San Diego
Agematsu, Kouta; Naito, Yuji; Aoki, Mitsuru; Fujiwara, Tadashi
2008-04-01
The presented case was a 3-year-old boy diagnosed with asplenia (SLL), double outlet right ventricle, pulmonary stenosis, atrioventricular septal defect, hypoplastic left ventricle and partial anomalous pulmonary venous connection to the superior vena cava. Partial anomalous pulmonary venous connection was repaired by translocation of pulmonary artery to avoid pulmonary venous obstruction when Glenn anastomosis was performed. Total cavo-pulmonary connection was established by re-routing the inferior vena cava to pulmonary artery using the atrial septal remnant and the left atrium free wall flap.
Internal jugular thrombophlebitis caused by dermal infection.
Yoshikawa, Hisao; Suzuki, Makoto; Nemoto, Naohiko; Hara, Hidehiko; Hashimoto, Go; Otsuka, Takenori; Moroi, Masao; Nakamura, Masato; Sugi, Kaoru
2011-01-01
A 29-year-old man presented with complaints of fever and pain and itching of his left neck with atopic dermatitis and abrasion. These symptoms had persisted for two days and dullness and fever developed, but the patient did not consult a physician. On the following day, he had a fever of 40°C and redness and swelling of the left neck. He visited a local clinic and was hospitalized with suspected cellulitis. A thrombus was detected in the internal jugular vein on MRI, and he was referred to our hospital. Neck ultrasonography showed the presence of an immovable thrombus in the area from the left internal jugular vein to the left brachiocephalic peripheral vein. Blood analysis indicated a major inflammatory response and juvenile idiopathic thrombophlebitis was suspected. A filter was carefully inserted into the superior vena cava, and anticoagulant therapy and medication with antibiotics led to remission. We present this case as a rare example of a condition mimicking Lemierre syndrome that was caused by dermal infection, and we include a review of the literature.
NASA Astrophysics Data System (ADS)
Hashemi-Dezaki, Hamed; Mohammadalizadeh-Shabestary, Masoud; Askarian-Abyaneh, Hossein; Rezaei-Jegarluei, Mohammad
2014-01-01
In electrical distribution systems, a great amount of power are wasting across the lines, also nowadays power factors, voltage profiles and total harmonic distortions (THDs) of most loads are not as would be desired. So these important parameters of a system play highly important role in wasting money and energy, and besides both consumers and sources are suffering from a high rate of distortions and even instabilities. Active power filters (APFs) are innovative ideas for solving of this adversity which have recently used instantaneous reactive power theory. In this paper, a novel method is proposed to optimize the allocation of APFs. The introduced method is based on the instantaneous reactive power theory in vectorial representation. By use of this representation, it is possible to asses different compensation strategies. Also, APFs proper placement in the system plays a crucial role in either reducing the losses costs and power quality improvement. To optimize the APFs placement, a new objective function has been defined on the basis of five terms: total losses, power factor, voltage profile, THD and cost. Genetic algorithm has been used to solve the optimization problem. The results of applying this method to a distribution network illustrate the method advantages.
Liu, Derek; Sloboda, Ron S
2014-05-01
Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.
Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele
2017-02-01
Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.
Sanders, Barbara P.; de los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G.; Song, Yutong; Cooper, Gillian; Crawt, Laura E.; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H. H. V.; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana
2016-01-01
The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4–9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV. PMID:27032093
Mechanical support of total cavopulmonary connection with an axial flow pump.
Riemer, R Kirk; Amir, Gabriel; Reichenbach, Steven H; Reinhartz, Olaf
2005-08-01
Even under optimal circumstances, total cavopulmonary connection is associated with a continuous late risk of death. Hemodynamics are distinctly abnormal, with increased systemic venous pressures and frequent low cardiac output. Our study uses a sheep model of total cavopulmonary connection to test the response to axial flow pump (Thoratec HeartMate II; Thoratec Corporation (Pleasanton, Calif)) support of total cavopulmonary connection, which might be suitable to treat patients with failing Fontan circulation. Eight sheep (42-48 kg) were studied. After pilot studies in 3 animals, 5 underwent both pump-supported and nonsupported total cavopulmonary connection in alternating sequence for up to 2 hours. This was achieved with a 12-mm polytetrafluoroethylene graft from the (distally ligated) superior vena cava to the main pulmonary artery and a cannula placed in the inferior vena cava with an attached 16-mm Dacron graft to the main pulmonary artery. Pressures (arterial, inferior vena cava, left atrium, and pulmonary artery) and flows (ascending aorta and inferior vena cava) were recorded over 1 hour both with unsupported total cavopulmonary connection and after placing an axial flow pump (Thoratec HeartMate II) between the inferior vena caval inflow cannula and the main pulmonary artery. Under nonsupported total cavopulmonary connection circulation, inferior vena caval and aortic blood flow decreased by nearly 50%. Inferior vena caval pressure nearly doubled, whereas arterial pressure decreased by one third. Pulmonary artery pressure became nonpulsatile; however, mean pulmonary artery pressure and left atrial pressure did not change significantly. With pump-supported Fontan circulation, cardiac output, inferior vena caval flow, and arterial pressure returned to baseline. Inferior vena caval pressure decreased to below baseline levels. Mean pulmonary artery pressure and left atrial pressure again remained unchanged. Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.
Sanders, Barbara P; de Los Rios Oakes, Isabel; van Hoek, Vladimir; Bockstal, Viki; Kamphuis, Tobias; Uil, Taco G; Song, Yutong; Cooper, Gillian; Crawt, Laura E; Martín, Javier; Zahn, Roland; Lewis, John; Wimmer, Eckard; Custers, Jerome H H V; Schuitemaker, Hanneke; Cello, Jeronimo; Edo-Matas, Diana
2016-03-01
The poliovirus vaccine field is moving towards novel vaccination strategies. Withdrawal of the Oral Poliovirus Vaccine and implementation of the conventional Inactivated Poliovirus Vaccine (cIPV) is imminent. Moreover, replacement of the virulent poliovirus strains currently used for cIPV with attenuated strains is preferred. We generated Cold-Adapted Viral Attenuation (CAVA) poliovirus strains by serial passage at low temperature and subsequent genetic engineering, which contain the capsid sequences of cIPV strains combined with a set of mutations identified during cold-adaptation. These viruses displayed a highly temperature sensitive phenotype with no signs of productive infection at 37°C as visualized by electron microscopy. Furthermore, decreases in infectious titers, viral RNA, and protein levels were measured during infection at 37°C, suggesting a block in the viral replication cycle at RNA replication, protein translation, or earlier. However, at 30°C, they could be propagated to high titers (9.4-9.9 Log10TCID50/ml) on the PER.C6 cell culture platform. We identified 14 mutations in the IRES and non-structural regions, which in combination induced the temperature sensitive phenotype, also when transferred to the genomes of other wild-type and attenuated polioviruses. The temperature sensitivity translated to complete absence of neurovirulence in CD155 transgenic mice. Attenuation was also confirmed after extended in vitro passage at small scale using conditions (MOI, cell density, temperature) anticipated for vaccine production. The inability of CAVA strains to replicate at 37°C makes reversion to a neurovirulent phenotype in vivo highly unlikely, therefore, these strains can be considered safe for the manufacture of IPV. The CAVA strains were immunogenic in the Wistar rat potency model for cIPV, inducing high neutralizing antibody titers in a dose-dependent manner in response to D-antigen doses used for cIPV. In combination with the highly productive PER.C6 cell culture platform, the stably attenuated CAVA strains may serve as an attractive low-cost and (bio)safe option for the production of a novel next generation IPV.
Kalicki, Boleslaw; Sadecka, Monika; Wawrzyniak, Agata; Kozinski, Piotr; Dziekiewicz, Miroslaw; Jung, Anna
2015-04-14
Absence of the inferior vena cava is a rare vascular anomaly, which usually remains asymptomatic in childhood. It is recognized as the risk factor for deep venous thrombosis, since the collateral circulation does not provide adequate drainage of the lower limbs. Mycoplasma pneumoniae is a common cause of community-acquired pneumonia in school-aged children and adolescents. Mycoplasma pneumoniae infection might be associated with deep venous thrombosis but its pathophysiology remains unknown. According to previous reports, deep venous thrombosis due to Mycoplasma pneumoniae infection is associated with positive serum anticardiolipin antibodies. To our knowledge, we describe the first case of deep venous thrombosis associated with Mycoplasma pneumoniae serum antibodies indicating early stage of infection with negative anticardiolipin serum antibodies in adolescent with absence of inferior vena cava. 14-year old boy was admitted to the pediatric unit few days after the appendectomy complaining with pain of the left hip that caused him unable to walk. The pain was accompanied with subfebrile temperature. After clinical examination and additional tests, the boy was diagnosed with a deep venous thrombosis. Computed tomography revealed absence of the vena cava inferior distally to the hepatic veins and varices of the collateral circulation in the pelvis. Anticardiolipin IgM and IgG antibodies and antinuclear antibodies were not detected. Additionally, the Mycoplasma pneumoniae antibodies in classes IgM, IgA and IgG were detected in serum as another risk factor of thrombosis. After the initial treatment with low-molecular-weight heparin in combination with clarithromycin the clinical condition of the patient improved. The patient became a candidate for life-long anticoagulation therapy. In this case Mycoplasma pneumoniae antibodies were associated with deep venous thrombosis in child with congenital absence of inferior vena cava. Uncommonly for deep venous thrombosis due to Mycoplasma pneumoniae infection, anticardiolipin antibodies were not detected in serum. It is important to remember in clinical practice that Mycoplasma pneumoniae affects coagulability and may trigger thrombosis, especially in the presence of other risk factors. The pathophysiology of this process remains unknown.
Lee, WonWoo; Oh, Jae Young; Kim, Eun-A; Kang, Nalae; Kim, Kil-Nam; Ahn, Ginnae; Jeon, You-Jin
2016-07-01
In this study, the beneficial prebiotic roles of Ecklonia cava (E. cava, EC) were evaluated on the growth of lactic acid bacteria (LAB) and pathogen bacteria and the mortality of pathogen-bacteria infected zebrafish model. The result showed that the original E. cava (EC) led to the highest growth effects on three LABs (Lactobacillus brevis, L. brevis; Lactobacillus pentosus, L. pentosus; Lactobacillus plantarum; L. plantarum) and it was dose-dependent manners. Also, EC, its Celluclast enzymatic (ECC) and 100% ethanol extracts (ECE) showed the anti-bacterial activities on the fish pathogenic bacteria such as (Edwardsiella tarda; E. tarda, Streptococcus iniae; S. iniae, and Vibrio harveyi; V. harveyi). Interestingly, EC induced the higher production of the secondary metabolites from L. plantarum in MRS medium. The secondary metabolites produced by EC significantly inhibited the growth of pathogen bacteria. In further in vivo study, the co-treatment of EC and L. plantarum improved the growth and mortality of E. tarda-infected zebrafish as regulating the expression of inflammatory molecules such as iNOS and COX2. Taken together, our present study suggests that the EC plays an important role as a potential prebiotic and has a protective effect against the infection caused by E. tarda injection in zebrafish. Also, our conclusion from this evidence is that EC can be used and applied as a useful prebiotic. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development and evaluation of evidence-based nursing (EBN) filters and related databases*
Lavin, Mary A.; Krieger, Mary M.; Meyer, Geralyn A.; Spasser, Mark A.; Cvitan, Tome; Reese, Cordie G.; Carlson, Judith H.; Perry, Anne G.; McNary, Patricia
2005-01-01
Objectives: Difficulties encountered in the retrieval of evidence-based nursing (EBN) literature and recognition of terminology, research focus, and design differences between evidence-based medicine and nursing led to the realization that nursing needs its own filter strategies for evidence-based practice. This article describes the development and evaluation of filters that facilitate evidence-based nursing searches. Methods: An inductive, multistep methodology was employed. A sleep search strategy was developed for uniform application to all filters for filter development and evaluation purposes. An EBN matrix was next developed as a framework to illustrate conceptually the placement of nursing-sensitive filters along two axes: horizontally, an adapted nursing process, and vertically, levels of evidence. Nursing diagnosis, patient outcomes, and primary data filters were developed recursively. Through an interface with the PubMed search engine, the EBN matrix filters were inserted into a database that executes filter searches, retrieves citations, and stores and updates retrieved citations sets hourly. For evaluation purposes, the filters were subjected to sensitivity and specificity analyses and retrieval set comparisons. Once the evaluation was complete, hyperlinks providing access to any one or a combination of completed filters to the EBN matrix were created. Subject searches on any topic may be applied to the filters, which interface with PubMed. Results: Sensitivity and specificity for the combined nursing diagnosis and primary data filter were 64% and 99%, respectively; for the patient outcomes filter, the results were 75% and 71%, respectively. Comparisons were made between the EBN matrix filters (nursing diagnosis and primary data) and PubMed's Clinical Queries (diagnosis and sensitivity) filters. Additional comparisons examined publication types and indexing differences. Review articles accounted for the majority of the publication type differences, because “review” was accepted by the CQ but was “NOT'd” by the EBN filter. Indexing comparisons revealed that although the term “nursing diagnosis” is in Medical Subject Headings (MeSH), the nursing diagnoses themselves (e.g., sleep deprivation, disturbed sleep pattern) are not indexed as nursing diagnoses. As a result, abstracts deemed to be appropriate nursing diagnosis by the EBN filter were not accepted by the CQ diagnosis filter. Conclusions: The EBN filter capture of desired articles may be enhanced by further refinement to achieve a greater degree of filter sensitivity. Retrieval set comparisons revealed publication type differences and indexing issues. The EBN matrix filter “NOT'd” out “review,” while the CQ filter did not. Indexing issues were identified that explained the retrieval of articles deemed appropriate by the EBN filter matrix but not included in the CQ retrieval. These results have MeSH definition and indexing implications as well as implications for clinical decision support in nursing practice. PMID:15685282
Strategies for the Management of SVC Stent Migration into the Right Atrium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, J. D., E-mail: drjeremytaylor@yahoo.co.uk; Lehmann, E. D.; Belli, A.-M.
Purpose. Stent migration into the right atrium is a potentially fatal complication of stenting in the venous system and is most likely to occur during the treatment of superior vena cava obstruction. Endovascular approaches that can salvage this hazardous situation are described and the keys to successful treatment are highlighted. Materials and Methods. Four different strategies are reviewed: (1) snaring the stent directly, (2) angioplasty balloon-assisted snaring of the stent, (3) guide wire-assisted snaring of the stent, and (4) superior vena cava-to-inferior vena cava bridging stent. Results. These techniques have been employed in the successful management of four cases. Nomore » short- or long-term complications as a result of these maneuvers have been identified. Additional treatment of the underlying disease was possible at the same time in each case. Conclusion. We conclude that prompt management of right atrial stent migration is essential and can be successfully achieved by a variety of 'bale-out' techniques which are within the technical range of most interventional radiologists.« less
Calcified inferior vena cava and right atrial myxoma in an 18-month-old male: A case report.
Chen, Renwei; Deng, Xicheng; Luo, Jinwen; Huang, Peng
2018-06-01
Cardiac myxomas are the most frequent primary cardiac tumor in adults. The incidence in pediatric patients is extremely low. Heavy calcification of an atrial myxoma is uncommon in children. An 18-month-old boy was admitted for a significant precordial systolic murmur. Transthoracic echocardiography revealed a cardiac mass extending from the inferior vena cava across the right atrium and tricuspid valve into the right ventricle with severe tricuspid regurgitation. According to the echocardiography result, the patient was diagnosed with an inferior vena cava and right atrial tumor with tricuspid regurgitation. After the diagnosis, the patient underwent removal of the tumor via median sternotomy. The mass was removed under cardiopulmonary bypass with deep hypothermia circulatory arrest. The tricuspid valve was repaired by valvuloplasty and annuloplasty. The postoperative recovery was unremarkable. Follow-up echocardiogram at 1 month revealed moderate tricuspid regurgitation without myxoma recurrence. Heavy calcification of an atrial myxoma is uncommon especially in children. Definitive therapy for myxomas requires prompt surgical excision and long-term follow-up is recommended in children although recurrence after excision is rare.
Liver hanging maneuver for right hemiliver in situ donation--anatomical considerations.
Trotovsek, B; Gadzijev, E M; Ravnik, D; Hribernik, M
2006-01-01
An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4-6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7+/-3.4 mm and to the entrance of segment 9 veins was 5.0+/-0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7+/-2.3 mm (range 2-15 mm). The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%).
NASA Technical Reports Server (NTRS)
Siwakosit, W.; Hess, R. A.; Bacon, Bart (Technical Monitor); Burken, John (Technical Monitor)
2000-01-01
A multi-input, multi-output reconfigurable flight control system design utilizing a robust controller and an adaptive filter is presented. The robust control design consists of a reduced-order, linear dynamic inversion controller with an outer-loop compensation matrix derived from Quantitative Feedback Theory (QFT). A principle feature of the scheme is placement of the adaptive filter in series with the QFT compensator thus exploiting the inherent robustness of the nominal flight control system in the presence of plant uncertainties. An example of the scheme is presented in a pilot-in-the-loop computer simulation using a simplified model of the lateral-directional dynamics of the NASA F18 High Angle of Attack Research Vehicle (HARV) that included nonlinear anti-wind up logic and actuator limitations. Prediction of handling qualities and pilot-induced oscillation tendencies in the presence of these nonlinearities is included in the example.
Trends in vena cava filter insertions and "prophylactic" use.
Power, John R; Nakazawa, Kenneth R; Vouyouka, Ageliki G; Faries, Peter L; Egorova, Natalia N
2018-04-17
Prophylactic vena cava filter (VCF) use in patients without venous thromboembolism is common practice despite ongoing controversy. Thorough analysis of the evolution of this practice is lacking. We describe trends in VCF use and identify events associated with changes in practice. Using the National Inpatient Sample, we conducted a retrospective observational study of U.S. adult hospitalizations from 2000 to 2014. Trends in prophylactic VCF insertion were analyzed both across the entire study population and within subgroups according to trauma status and type of concurrent surgery. Annual percentage change (APC) was calculated, and trends were analyzed using Poisson regression. Among 461,904,314 adult inpatients (median [interquartile range] age, 58.1 [38.5-74.3] years; 39.6% male), the incidence of VCF insertion increased rapidly at first (from 0.19% to 0.35%; APC, 11.2%; 95% confidence interval [CI], 10.3%-12.2%; P < .001), then at a slower rate after the publication of the Prévention du Risque d'Embolie Pulmonaire par Interruption Cave 2 (PREPIC2) trial in 2005 (from 0.35% to 0.42%; APC, 4.4%; 95% CI, 2.8%-6.0%; P < .001), and it began decreasing after the 2010 Food and Drug Administration (FDA) safety alert (from 0.42% to 0.32%; APC, -5.5%; 95% CI, -6.5% to -4.6%; P < .001). The percentage of total VCFs that had a prophylactic indication increased quickly before publication of the PREPIC2 trial (APC, 19.5%; 95% CI, 17.9%-21.0%; P < .001), increased at a slower rate after publication in 2005 (APC, 4.4%; 95% CI, 2.6%-6.2%; P < .001), and dropped after the FDA safety alert, stabilizing at 18.5% for the last 3 years (APC, -0.3%; 95% CI, -2.2% to 1.7%; P = .8). Subgroups most associated with prophylactic VCF insertion were operative trauma (odds ratio [OR], 10.9; 95% CI, 10.2-11.7), orthopedic surgery (OR, 4.7; 95% CI, 4.3-5.2), and neurosurgical procedures (OR, 3.9; 95% CI, 3.6-4.2). All groups except orthopedic surgery experienced a deceleration in prophylactic VCF growth after the publication of PREPIC2. Meanwhile, the FDA safety alert was associated with a decrease in prophylactic VCF insertions for all groups except other major surgery. Whereas publication of the PREPIC2 trial led to a deceleration in prophylactic VCF insertion growth, the FDA alert had a bigger impact, leading to declining rates of prophylactic VCF use. Further investigations of prophylactic insertion of VCF in trauma, orthopedic, and neurosurgical patients are needed to determine whether current levels of use are justified. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Turkoz, Riza; Ayabakan, Canan; Vuran, Can; Omay, Oğuz
2010-08-01
A 7-month-old boy with heterotaxy syndrome had partial atrioventricular septal defect and interrupted inferior vena cava with hemiazygos continuation to a left superior vena cava. The left side of the common atrium receiving all the venous drainage was in connection with the left ventricle and the aorta. The small atrium and the proximity of the pulmonary and hepatic vein orifices precluded complete baffling. This report describes an intraatrial baffle repair of anomalous systemic venous return without hepatic venous drainage. This resulted in good oxygenation postoperatively, with oxygen saturation ranging from 93% to 98%.
Superior Vena Cava Stent Migration into the Pulmonary Artery Causing Fatal Pulmonary Infarction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anand, Girija, E-mail: gijanandm@hotmail.com; Lewanski, Conrad R.; Cowman, Steven A.
2011-02-15
Migration of superior vena cava (SVC) stents is a well-recognised complication of their deployment, and numerous strategies exist for their retrieval. To our knowledge, only three cases of migration of an SVC stent to the pulmonary vasculature have previously been reported. None of these patients developed complications that resulted in death. We report a case of SVC stent migration to the pulmonary vasculature with delayed pulmonary artery thrombosis and death from pulmonary infarction. We conclude that early retrieval of migrated stents should be performed to decrease the risk of serious complications.
Jacobi, C A; Junghans, T; Peter, F; Naundorf, D; Ordemann, J; Müller, J M
2000-11-01
Injury of venous vessels during elevated intraperitoneal pressure is thought to cause possible fatal gas embolism, and helium may be dangerous because of its low solubility. Twenty pigs underwent laparoscopy with either CO2 (n=10) or helium (n=10) with a pressure of 15 mm Hg and standardized laceration (1 cm) of the vena cava inferior. After 30 s, the vena cava was clamped, closed endoscopically by a running suture and unclamped again. During the procedure changes of cardiac output (CO), heart rate (HR), mean arterial pressure (MAP), central venous pressure (CVP), pulmonary artery pressure (PAP), pulmonary artery wedge pressure (PAWP), end tidal CO2 pressure (PETCO2), and arterial blood gas analyses (pH, pO2 and pCO2) were investigated. No animal died during the experimental course (mean blood loss during laceration: CO2, 157+/-50 ml; helium, 173+/-83 ml). MAP and CO values showed a decrease after laceration of the vena cava in both groups that had already been completely compensated for before suturing. PETCO2 increased significantly after CO2 insufflation (P<0.01), while helium showed no effect. Laceration of the vena cava caused no significant changes in PETCO2 values in either group. Significant acidosis and an increase of pCO2 were only found in the CO2 group. The incidence of gas embolism during laparoscopy and accidental vessel injury seems to be very low. With the exception of acidosis and an increase of PETCO2 in the CO2 group, there were no differences in cardiopulmonary function between insufflation of CO2 and helium.
Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin
2014-01-01
Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418
NASA Astrophysics Data System (ADS)
Alonso-Henar, Jorge; Alvarez-Gomez, José Antonio; Jesús Martinez-Diaz, José
2017-04-01
The Central American Volcanic Arc (CAVA) is located at the western margin of the Caribbean plate, over the Chortís Block, spanning from Guatemala to Costa Rica. The CAVA is associated to the subduction of the Cocos plate under the Caribbean plate at the Middle America Trench. Our study is focused in the Salvadorian CAVA segment, which is tectonically characterized by the presence of the El Salvador Fault Zone (ESFZ), part of the western boundary of a major block forming the Caribbean plate (the Chortis Block). The structural evolution of the western boundary of the Chortis Block, particularly in the CAVA crossing El Salvador remains unknown. We have done a kinematic analysis from seismic and fault slip data and combined our results with a review of regional previous studies. This approach allowed us to constrain the tectonic evolution and the forces that control the deformation in northern Central America. Along the active volcanic arc we identified active transtensional deformation. On the other hand, we have identified two deformation phases in the back arc region: A first one of transpressional wrenching close to simple shearing (Miocene); and a second one characterized by almost E-W extension. Our results reveal a change from transpressional to transtensional shearing coeval with a migration of the volcanism towards the trench in Late Miocene times. This strain change could be related with a coupled to decoupled transition on the Cocos - Caribbean subduction interface, which could be related to a slab roll-back of the Cocos Plate beneath the Chortis Block. The combination of different degrees of coupling on the subduction interface, together with a constant relative eastward drift of the Caribbean Plate, control the deformation style along the western boundary of the Chortis Block.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com; Akdogan, Meral, E-mail: akdmeral@yahoo.com; Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com
PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture andmore » traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.« less
Experimental Evaluation of UWB Indoor Positioning for Sport Postures
Defraye, Jense; Steendam, Heidi; Gerlo, Joeri; De Clercq, Dirk; De Poorter, Eli
2018-01-01
Radio frequency (RF)-based indoor positioning systems (IPSs) use wireless technologies (including Wi-Fi, Zigbee, Bluetooth, and ultra-wide band (UWB)) to estimate the location of persons in areas where no Global Positioning System (GPS) reception is available, for example in indoor stadiums or sports halls. Of the above-mentioned forms of radio frequency (RF) technology, UWB is considered one of the most accurate approaches because it can provide positioning estimates with centimeter-level accuracy. However, it is not yet known whether UWB can also offer such accurate position estimates during strenuous dynamic activities in which moves are characterized by fast changes in direction and velocity. To answer this question, this paper investigates the capabilities of UWB indoor localization systems for tracking athletes during their complex (and most of the time unpredictable) movements. To this end, we analyze the impact of on-body tag placement locations and human movement patterns on localization accuracy and communication reliability. Moreover, two localization algorithms (particle filter and Kalman filter) with different optimizations (bias removal, non-line-of-sight (NLoS) detection, and path determination) are implemented. It is shown that although the optimal choice of optimization depends on the type of movement patterns, some of the improvements can reduce the localization error by up to 31%. Overall, depending on the selected optimization and on-body tag placement, our algorithms show good results in terms of positioning accuracy, with average errors in position estimates of 20 cm. This makes UWB a suitable approach for tracking dynamic athletic activities. PMID:29315267
Karls, Shawn; Hassoun, Hani; Derbekyan, Vilma
2016-09-01
A 67-year-old male presented with dyspnea for which lung scintigraphy was ordered to rule out pulmonary embolus. Planar images demonstrated abnormal midline uptake of Tc-99m macroaggregated albumin, which SPECT/CT localized to several thoracic vertebrae. Thoracic vertebral uptake on perfusion lung scintigraphy was previously described on planar imaging. Radionuclide venography and contrast-enhanced CT subsequently demonstrated superior vena cava (SVC) obstruction with collateralization through the azygous/hemiazygous system and vertebral venous plexus. SPECT/CT differentiated residual esophageal/tracheal ventilation activity, a clinically insignificant finding, from vertebral uptake indicative of SVC obstruction, a potentially life-threatening condition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul
Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.
Perri, Gianluigi; Filippelli, Sergio; Kirk, Richard; Hasan, Asif; Griselli, Massimo
2012-05-01
Anomalies of the pulmonary venous drainage vary widely in their anatomic spectrum and clinical presentation. We describe an unusual case of supra-cardiac total anomalous pulmonary venous connection (TAPVC), where the pulmonary veins drained directly in the posterior aspect of proximal right superior vena cava (SVC) through separate ostia. The veins were re-routed with a patch to the left atrium via the secundum atrial septal defect (ASD). The continuity between distal SVC and right atrium was re-established by re-implanting the SVC to the right atrial appendage (Warden Procedure). © 2012 Wiley Periodicals, Inc.
Focal Atrial Tachycardia Arising from the Inferior Vena Cava
Lim, Yeong-Min; Uhm, Jae-Sun
2017-01-01
The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006
Temporary bypass for superior vena cava reconstruction with Anthron bypass tubeTM
Yamasaki, Naoya; Tsuchiya, Tomoshi; Miyazaki, Takuro; Kamohara, Ryotaro; Hatachi, Go; Nagayasu, Takeshi
2017-01-01
Total superior vena cava (SVC) clamping for SVC replacement or repair can be used in thoracic surgery. A bypass technique is an option to avoid hemodynamic instability and cerebral venous hypertension and hypoperfusion. The present report describes a venous bypass technique using Anthron bypass tubeTM for total SVC clamping. Indications for this procedure include the need for a temporary bypass between the brachiocephalic vein and atrium for complete tumor resection. This procedure allows the surgeons sufficient time to complete replacement of SVC or partial resection of SVC without adverse effects. Further, it is a relatively simple procedure requiring minimal time. PMID:28840027
Tashi, Sonam; Ng, Keng Sin
2015-01-01
Cushing’s syndrome is known to have a wide spectrum of clinical presentation with debilitating consequences and morbidity if not diagnosed and treated in time. Sometimes the diagnosis of Cushing’s syndrome can be challenging to the endocrinologist, especially when the usual battery of biochemical tests and advanced cross-sectional imaging is negative or inconclusive. We described a case in which the use of bilateral inferior petrosal sinus sampling (BIPSS) was conclusive albeit being technically challenging (due to a rare incidental finding of double superior vena cava) and invasive in nature. PMID:26629301
Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay
2015-04-01
Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.
Ko, Seok-Chun; Lee, Myoungsook; Lee, Ji-Hyeok; Lee, Seung-Hong; Lim, Yunsook; Jeon, You-Jin
2013-11-01
In this study, we assessed the potential inhibitory effect of 5 species of brown seaweeds on adipogenesis the differentiation of 3T3-L1 preadipocytes into mature adipocytes by measuring Oil-Red O staining. The Ecklonia cava extract tested herein evidenced profound adipogenesis inhibitory effect, compared to that exhibited by the other four brown seaweed extracts. Thus, E. cava was selected for isolation of active compounds and finally the three polyphenol compounds of phlorotannins were obtained and their inhibitory effect on adipogenesis was observed. Among the phlorotannins, dieckol exhibited greatest potential adipogenesis inhibition and down-regulated the expression of peroxisome proliferator-activated receptor-γ (PPARγ), CCAAT/enhancer-binding proteins (C/EBPα), sterol regulatory element-binding protein 1 (SREBP1) and fatty acid binding protein 4 (FABP4) in a dose-dependent manner. The specific mechanism mediating the effects of dieckol was confirmed by AMP-activated protein kinase (AMPK) activation. These results demonstrate inhibitory effect of dieckol compound on adipogenesis through the activation of the AMPK signal pathway. Copyright © 2013 Elsevier B.V. All rights reserved.
Morphology of congenital portosystemic shunts involving the left colic vein in dogs and cats.
White, R N; Parry, A T
2016-05-01
To describe the anatomy of congenital portosystemic shunts involving the left colic vein in dogs and cats. Retrospective review of a consecutive series of dogs and cats managed for congenital portosystemic shunts. For inclusion a shunt involving the left colic vein with recorded intraoperative mesenteric portovenography or computed tomography angiography along with direct gross surgical observations at the time of surgery was required. Six dogs and three cats met the inclusion criteria. All cases had a shunt which involved a distended left colic vein. The final communication with a systemic vein was variable; in seven cases (five dogs, two cats) it was via the caudal vena cava, in one cat it was via the common iliac vein and in the remaining dog it was via the internal iliac vein. In addition, two cats showed caudal vena cava duplication. The morphology of this shunt type appeared to be a result of an abnormal communication between either the left colic vein or the cranial rectal vein and a pelvic systemic vein (caudal vena cava, common iliac vein or internal iliac vein). This information may help with surgical planning in cases undergoing shunt closure surgery. © 2016 British Small Animal Veterinary Association.
Zhu, Guanchen; Qiu, Xuefeng; Chen, Xianchen; Liu, Guangxiang; Zhang, Gutian; Gan, Weidong; Guo, Hongqian
2015-12-01
Renal cell carcinoma (RCC) accounts for 85-90% of kidney cancers, which in turn account for 2-3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7-10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC.
ZHU, GUANCHEN; QIU, XUEFENG; CHEN, XIANCHEN; LIU, GUANGXIANG; ZHANG, GUTIAN; GAN, WEIDONG; GUO, HONGQIAN
2015-01-01
Renal cell carcinoma (RCC) accounts for 85–90% of kidney cancers, which in turn account for 2–3% of all malignant tumors in adults. Xp11.2 translocation/TFE3 gene fusion RCC is currently classified as a distinct type of RCC. RCC is capable of invading the renal vein and inferior vena cava to form a tumor thrombus. The incidence of RCC with tumor thrombi within the renal vein or inferior vena cava is 7–10% in China. In the present case report, the patient underwent radical resection of the renal tumor and removal of the tumor thrombus, assisted by cardiopulmonary bypass, for the treatment of Xp11.2 translocation/TFE3 gene fusion RCC. The patient was followed-up for 12 months subsequent to treatment. The patient's renal function remained within the normal range, and computed tomography examination revealed no evidence of disease recurrence or metastases. The present case report aimed to provide a reference for the development of guidelines for the diagnosis and treatment of Xp11.2 translocation/TFE3 gene fusion RCC. PMID:26788164
Inferior vena cava tumor thrombus after partial nephrectomy for renal cell carcinoma.
Akatsuka, Jun; Suzuki, Yasutomo; Hamasaki, Tsutomu; Shindo, Takao; Yanagi, Masato; Kimura, Go; Yamamoto, Yoichiro; Kondo, Yukihiro
2014-03-29
Partial nephrectomy is now the gold standard treatment for small renal tumors. Local recurrence is a major problem after partial nephrectomy, and local recurrence in the remnant kidney after partial nephrectomy is common. A 77-year-old man underwent right partial nephrectomy for a T1 right renal cell carcinoma. Microscopic examination revealed a clear cell renal carcinoma, grade 2, stage pT3a. Although the surgical margin was negative, the carcinoma invaded the perirenal fat, and vascular involvement was strongly positive. Thirty months after partial nephrectomy, an enhanced computed tomographic scan showed local recurrence of the renal cell carcinoma extending into the inferior vena cava without renal mass. Hence, we performed right radical nephrectomy and intracaval thrombectomy. Microscopic examination revealed a clear cell carcinoma grade 2, stage pT3a + b. The patient is still alive with no evidence of recurrence 10 months post-procedure. To our knowledge, local recurrence of renal cell carcinoma extending into the inferior vena cava after partial nephrectomy has not been reported in the literature. Our case report emphasizes the importance of strict surveillance of patients after partial nephrectomy, especially for those with renal cell carcinoma positive for microvessel involvement.
Liver hanging maneuver for right hemiliver in situ donation – anatomical considerations
Gadžijev, E.M.; Ravnik, D.; Hribernik, M.
2006-01-01
Background. An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4–6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. Materials and methods. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. Results. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7±3.4 mm and to the entrance of segment 9 veins was 5.0±0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7±2.3 mm (range 2–15 mm). Discussion. The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%). PMID:18333236
Been, Ken; Daiches, Eli; Yap, Chee
2006-01-01
We address the problem of filtering, selecting and placing labels on a dynamic map, which is characterized by continuous zooming and panning capabilities. This consists of two interrelated issues. The first is to avoid label popping and other artifacts that cause confusion and interrupt navigation, and the second is to label at interactive speed. In most formulations the static map labeling problem is NP-hard, and a fast approximation might have O(nlogn) complexity. Even this is too slow during interaction, when the number of labels shown can be several orders of magnitude less than the number in the map. In this paper we introduce a set of desiderata for "consistent" dynamic map labeling, which has qualities desirable for navigation. We develop a new framework for dynamic labeling that achieves the desiderata and allows for fast interactive display by moving all of the selection and placement decisions into the preprocessing phase. This framework is general enough to accommodate a variety of selection and placement algorithms. It does not appear possible to achieve our desiderata using previous frameworks. Prior to this paper, there were no formal models of dynamic maps or of dynamic labels; our paper introduces both. We formulate a general optimization problem for dynamic map labeling and give a solution to a simple version of the problem. The simple version is based on label priorities and a versatile and intuitive class of dynamic label placements we call "invariant point placements". Despite these restrictions, our approach gives a useful and practical solution. Our implementation is incorporated into the G-Vis system which is a full-detail dynamic map of the continental USA. This demo is available through any browser.
Lauten, Alexander; Figulla, Hans R; Unbehaun, Axel; Fam, Neil; Schofer, Joachim; Doenst, Torsten; Hausleiter, Joerg; Franz, Marcus; Jung, Christian; Dreger, Henryk; Leistner, David; Alushi, Brunilda; Stundl, Anja; Landmesser, Ulf; Falk, Volkmar; Stangl, Karl; Laule, Michael
2018-02-01
Transcatheter caval valve implantation is under evaluation as a treatment option for inoperable patients with severe tricuspid regurgitation (TR). The procedure involves the catheter-based implantation of bioprosthetic valves in the inferior vena cava and superior vena cava to treat symptoms associated with TR. This study is the first to evaluate the feasibility, safety, and efficacy of this interventional concept. Twenty-five patients (mean age, 73.9±7.6 years; women, 52.0%) with severe symptomatic TR despite optimal medical treatment deemed unsuitable for surgery were treated with caval valve implantation under a compassionate clinical use program. Technical feasibility defined as procedural success, hemodynamic effect defined as venous pressure reduction, and safety defined as periprocedural adverse events were evaluated, with clinical follow-up at discharge and up to 12 months. The functional impact was evaluated by assessment of New York Heart Association class at the time of hospital discharge. The total number of valves implanted in the caval position was 31. Patients were treated with single (inferior vena cava-only; n=19; 76.0%) or bicaval valve implantation (inferior vena cava+superior vena cava; n=6; 24.0%). Either balloon-expandable valves (Sapien XT/3: n=18; 72.0%) or self-expandable valves (TricValve: n=6; 24.0%; Directflow: n=1; 4.0%) were used. Procedural success was achieved in 96% (n=24). Early and late valve migration requiring surgical intervention occurred in 1 patient each. Thirty-day and in-hospital mortality were 8% (2 of 25) and 16% (4 of 25). Causes of in-hospital mortality included respiratory (n=1) or multiple organ failure (n=3) and were not linked to the procedure. Mean overall survival in the study cohort was 316±453 days (14-1540 days). Caval valve implantation for the treatment of severe TR and advanced right ventricular failure is associated with a high procedural success rate and seems safe and feasible in an excessive-risk cohort. The study demonstrates hemodynamic efficacy with consistent elimination of TR-associated venous backflow and initial clinical improvement. These results encourage further trials to determine which patients benefit most from this interventional approach. © 2018 American Heart Association, Inc.
Large thoracic tumor without superior vena cava syndrome.
Garmpis, Nikolaos; Damaskos, Christos; Patelis, Nikolaos; Dimitroulis, Dimitrios; Spartalis, Eleftherios; Tomos, Ioannis; Garmpi, Anna; Spartalis, Michael; Antoniou, Efstathios A; Kontzoglou, Konstantinos; Tomos, Periklis
2017-04-10
A 62 year-old male with long-standing smoking history presented with hemoptysis. Plain chest x-ray showed abnormal findings proximate to the right pulmonary hilum. Bronchoscopy revealed a fragile exophytic tumor of the right wall of the lower third of the trachea, infiltrating the right main bronchus (75% stenosis) and the right upper lobar bronchus (near total occlusion). Contrast-enhanced chest CT demonstrated a 7.2x4.9 cm tumor contiguous to the above-mentioned structures, mediastinal lymph node pathology, and a vessel coursing inferiorly to the left of the aortic arch and anterior to the left hilum. Despite the tumor constricting the right superior vena cava, no signs of superior vena cava syndrome were present. In this case, the patient does not present with Superior Vena Cava (SVC) syndrome, as expected due to the constriction of the (right) SVC caused by the tumor, since head and neck veins drain through the Persistent Left Superior Vena Cava (PLSVC). PLSVC is the most common thoracic venous anomaly with an incidence of 0.3% to 0.5% of the general population and it is a congenital anomaly caused by the failure of the left anterior cardinal vein to regress and to consequently form the ligament of Marshall during fetal development. It is associated with absence of the left brachiocephalic vein and in 10 to 20% of cases the right SVC is absent. Two potential draining points of the PLSVC have been previously reported. In the majority of cases PLSVC drains directly into the coronary sinus, but less frequently it drains into the left atrium or the left superior pulmonary vein. In cases where the PLSVC drains into the coronary sinus, congenital heart defects are rare. The patient usually remains asymptomatic and PLSVC is an incidental finding during radiographic imaging or medical procedures. When the PLSVC drains into the left atrium or the left superior pulmonary vein, a right-to-left shunt is formed; a condition usually asymptomatic. In some reported cases this PLSVC variant presents with persistent, unexplained hypoxia or cyanosis and embolisation causing recurrent transient ischemic attacks and/or cerebral abscesses. This PLSVC variant is more often associated with absence of the right SVC and congenital heart abnormalities.
Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.
Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G
2013-04-01
This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.
Miessau, J; Yang, Q; Unai, S; Entwistle, J W C; Cavarocchi, N C; Hirose, H
2015-07-01
We report a unique utilization of a double-lumen, bi-caval Avalon cannula for veno-venous (VV) extracorporeal membrane oxygenation (ECMO) during placement of a total artificial heart (TAH, SynCardia, Tucson, AZ). A 22-year-old female with post-partum cardiomyopathy was rescued on veno-arterial (VA) ECMO because of cardiogenic shock. The inability to wean ECMO necessitated implantation of the TAH as a bridge to transplant. In addition, the patient continued to have respiratory failure and concomitant VV ECMO was planned with the implant. During TAH implantation, the Avalon cannula was placed percutaneously from the right internal jugular vein into the inferior vena cava (IVC) under direct vision while the right atrium was open. During VV ECMO support, adequate flows on both ECMO and TAH were maintained without adverse events. VV ECMO was discontinued, without reopening the chest, once the patient's respiratory failure improved. However, the patient subsequently developed a profound respiratory acidosis and required VV ECMO for CO2 removal. The Avalon cannula was placed in the femoral vein to avoid accessing the internal jugular vein and risking damage to the TAH. The patient's oxygenation eventually improved and the cannula was removed at the bedside. The patient was supported for 22 days on VV ECMO and successfully weaned from the ventilator prior to her orthotropic heart transplantation. © The Author(s) 2014.
Mold contamination of automobile air conditioner systems.
Kumar, P; Lopez, M; Fan, W; Cambre, K; Elston, R C
1990-02-01
Eight cars belonging to patients who were found to have exacerbation of allergic rhinitis and bronchial asthma after turning on the air conditioner in their cars were examined. Mold concentrations inside the passenger compartment with the a/c turned off and at different climate control settings were lower than concentrations in the outside air. After turning on the air conditioner to "Max", cultures obtained at various intervals revealed that mold concentrations decreased significantly with time. Furthermore, placement of a filter at the portal of entry of outside air significantly reduced the mold concentration in the passenger compartment.
Sustained-release subconjunctival 5-fluorouracil.
Smith, T J; Ashton, P
1996-09-01
The purpose of this research was to obtain preliminary safety and efficacy data on a novel sustained-release 5-fluorouracil (5-FU) implant in high-risk glaucoma surgical patients. The implants were placed subconjunctivally in four patients undergoing high-risk trabeculectomy. The patients have been observed for approximately 2.5 years. In three of the four patients intraocular pressure was controlled at less than 21 mm Hg, with stabilization of the visual field. One patient had early failure. No untoward events were linked to the placement of the implant. Sustained-release systems for subconjunctival 5-FU may be useful in filter maintenance.
Prevention of venous thromboembolism in patients undergoing bariatric surgery
Bartlett, Matthew A; Mauck, Karen F; Daniels, Paul R
2015-01-01
Bariatric surgical procedures are now a common method of obesity treatment with established effectiveness. Venous thromboembolism (VTE) events, which include deep vein thrombosis and pulmonary embolism, are an important source of postoperative morbidity and mortality among bariatric surgery patients. Due to an understanding of the frequency and seriousness of these complications, bariatric surgery patients typically receive some method of VTE prophylaxis with lower extremity compression, pharmacologic prophylaxis, or both. However, the optimal approach in these patients is unclear, with multiple open questions. In particular, strategies of adjusted-dose heparins, postdischarge anticoagulant prophylaxis, and the role of vena cava filters have been evaluated, but only to a limited extent. In contrast to other types of operations, the literature regarding VTE prophylaxis in bariatric surgery is notable for a dearth of prospective, randomized clinical trials, and current professional guidelines reflect the uncertainties in this literature. Herein, we summarize the available evidence after systematic review of the literature regarding approaches to VTE prevention in bariatric surgery. Identification of risk factors for VTE in the bariatric surgery population, analysis of the effectiveness of methods used for prophylaxis, and an overview of published guidelines are presented. PMID:26316771
Primary Pulmonary Ewing's Sarcoma: Rare Cause of Superior Vena Cava Syndrome in Children.
Mehra, Shibani; Atwal, Swapndeep Singh; Garga, Umesh Chandra
2014-08-01
Ewing's sarcoma is a common malignant bone tumour presenting in children and young adults. Rarely extra- skeletal soft tissues and visceral organs can also be the site of origin of Ewing's sarcoma. Primary pulmonary Ewing's sarcoma is an extremely rare malignancy which occurs in the paediatric population. We report an unusual case of primary pulmonary Ewing's sarcoma in a nine year old girl who presented with features of superior vena cava syndrome in the emergency department. The diagnosis was confirmed pathologically both by light microscopy and immunohistochemistry. The patient was put on chemotherapy and surgery was planned but the patient expired within three days of starting chemotherapy.
Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra
2014-01-01
Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC. PMID:25506021
Acar, Turker; Harman, Mustafa; Guneyli, Serkan; Sen, Sait; Elmas, Nevra
2014-01-01
Epithelioid angiomyolipoma (E-AML), accounting for 8% of renal angiomyolipoma, is usually associated with tuberous sclerosis (TS) and demonstrates aggressive behavior. E-AML is macroscopically seen as a large infiltrative necrotic tumor with occasional extension into renal vein and/or inferior vena cava. However, without history of TS, renal sinus and venous invasion E-AML would be a challenging diagnosis, which may lead radiologists to misinterpret it as a renal cell carcinoma (RCC). In this case presentation, we aimed to report cross-sectional imaging findings of two cases diagnosed as E-AML and pathological correlation of these aforementioned masses mimicking RCC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erol, Ilknur; Cetin, I. Ilker; Alehan, Fuesun
A previously healthy 12-year-old girl presented with severe headache for 2 weeks. On physical examination, there was finger clubbing without apparent cyanosis. Neurological examination revealed only papiledema without focal neurologic signs. Cerebral magnetic resonance imaging showed the characteristic features of brain abscess in the left frontal lobe. Cardiologic workup to exclude a right-to-left shunt showed an abnormality of the systemic venous drainage: presence of isolated left superior vena cava draining into the left atrium in the absence of coronary sinus and atrial septal defect. This anomaly is rare, because only a few other cases have been reported.
Wu, Yuan; Xu, Shuangyue; Guo, Hongwei; Yan, Guoliang; Qi, Zhongquan; Shan, Zhonggui
2014-07-01
We report a case of a 44-year-old male patient with ectopic drainage from the inferior vena cava to the left atrium accompanied by partial anomalous pulmonary venous drainage. After the patient was hospitalized, his diagnosis was confirmed by Doppler echocardiography and angiography. A pericardial patch was used to divert the blood to the atrium. The surgical procedure was successful, and the patient began a rehabilitation program 8 days later. This type of ectopic drainage pattern is an unusual and infrequent clinical finding. The definitive diagnosis should be made by Doppler ultrasound combined with angiography. Copyright © 2014 Elsevier Inc. All rights reserved.
Wang, Yishan; Doleschel, Sammy; Wunderlich, Ralf; Heinen, Stefan
2015-03-01
This paper presents a wearable wireless ECG monitoring system based on novel 3-Lead electrode placements for long-term homecare. The experiment for novel 3-Lead electrode placements is carried out, and the results show that the distance between limb electrodes can be significantly reduced. Based on the new electrode position, a small size sensor node, which is powered by a rechargeable battery, is designed to detect, amplify, filter and transmit the ECG signals. The coordinator receives the data and sends it to PC. Finally the signals are displayed on the GUI. In order to control the power consumption of sensor node, a dynamic power adjustment method is applied to automatically adjust the transmission power of the sensor node according to the received signal strength indicator (RSSI), which is related to the distance and obstacle between sensor node and coordinator. The system is evaluated when the user, who wears the sensor, is walking and running. A promising performance is achieved even under body motion. The power consumption can be significantly reduced with this dynamic power adjustment method.
Ensemble-based data assimilation and optimal sensor placement for scalar source reconstruction
NASA Astrophysics Data System (ADS)
Mons, Vincent; Wang, Qi; Zaki, Tamer
2017-11-01
Reconstructing the characteristics of a scalar source from limited remote measurements in a turbulent flow is a problem of great interest for environmental monitoring, and is challenging due to several aspects. Firstly, the numerical estimation of the scalar dispersion in a turbulent flow requires significant computational resources. Secondly, in actual practice, only a limited number of observations are available, which generally makes the corresponding inverse problem ill-posed. Ensemble-based variational data assimilation techniques are adopted to solve the problem of scalar source localization in a turbulent channel flow at Reτ = 180 . This approach combines the components of variational data assimilation and ensemble Kalman filtering, and inherits the robustness from the former and the ease of implementation from the latter. An ensemble-based methodology for optimal sensor placement is also proposed in order to improve the condition of the inverse problem, which enhances the performances of the data assimilation scheme. This work has been partially funded by the Office of Naval Research (Grant N00014-16-1-2542) and by the National Science Foundation (Grant 1461870).
Rationale of cerebral protection devices in left atrial appendage occlusion.
Meincke, Felix; Spangenberg, Tobias; Kreidel, Felix; Frerker, Christian; Virmani, Renu; Ladich, Elena; Kuck, Karl-Heinz; Ghanem, Alexander
2017-01-01
Aims of this case-series were to assess the feasibility of cerebral protection devices in interventional left atrial appendage occlusion (iLAAO) procedures and to yield insight into the pathomorphological correlate of early, procedural cerebral embolization during iLAAO. Five consecutive patients underwent iLLO flanked by the Sentinel CPS® (Claret Medical, Inc., Santa Rosa, CA) cerebral protection system. Placement and recapture of the Sentinel ® device as well as the iLAAO were successful and safe in all cases. Histomorphometric analysis of the collected filters showed embolized debris in all patients. Acute thrombus was found in three patients, organizing thrombus in four. Interestingly, two patients had endocardial or myocardial tissue in their filters. Cerebral protection during iLAAO with the Sentinel CPS ® device is feasible. Furthermore, this dataset identifies the formation and embolization of thrombus and cardiac tissue as emboligeneic sources and potential future targets to reduce procedural complications. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Pratschke, Sebastian; Rauch, Alexandra; Albertsmeier, Markus; Rentsch, Markus; Kirschneck, Michaela; Andrassy, Joachim; Thomas, Michael; Hartwig, Werner; Figueras, Joan; Del Rio Martin, Juan; De Ruvo, Nicola; Werner, Jens; Guba, Markus; Weniger, Maximilian; Angele, Martin K
2016-12-01
The value of temporary intraoperative porto-caval shunts (TPCS) in cava-sparing liver transplantation is discussed controversially. Aim of this meta-analysis was to analyze the impact of temporary intraoperative porto-caval shunts on liver injury, primary non-function, time of surgery, transfusion of blood products and length of hospital stay in cava-sparing liver transplantation. A systematic search of MEDLINE/PubMed, EMBASE and PsycINFO retrieved a total of 909 articles, of which six articles were included. The combined effect size and 95 % confidence interval were calculated for each outcome by applying the inverse variance weighting method. Tests for heterogeneity (I 2 ) were also utilized. Usage of a TPCS was associated with significantly decreased AST values, significantly fewer transfusions of packed red blood cells and improved postoperative renal function. There were no statistically significant differences in primary graft non-function, length of hospital stay or duration of surgery. This meta-analysis found that temporary intraoperative porto-caval shunts in cava-sparing liver transplantation reduce blood loss as well as hepatic injury and enhance postoperative renal function without prolonging operative time. Randomized controlled trials investigating the use of temporary intraoperative porto-caval shunts are needed to confirm these findings.
Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli
NASA Technical Reports Server (NTRS)
Butler, B. D.; Morris, W. P.
1995-01-01
Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.
Rubartelli, Paolo; Brusa, Giulia; Arrigo, Alessandro; Abbadessa, Francesco; Giachero, Corinna; Vischi, Massimo; Ricca, Maria Maddalena; Ottonello, Gian Andrea
2006-08-01
To compare the efficacy of 2 emboli protection devices in preventing embolization during carotid artery stenting (CAS). The GuardWire distal occlusion system (n=19) and the distal FilterWire EX (n=12) were compared in 31 consecutive patients (24 men; mean age 71+/-10 years) monitored with transcranial Doppler for microembolic signals before, during, and after CAS. The choice of the protection device was based on availability and on the patency of the contralateral carotid artery. The baseline characteristics were similar in the patients treated under protection from either device. Placement and retrieval of the protection device, stenting, and postdilation were technically successful in all patients. Two patients suffered a transient ischemic attack shortly after the procedure; no other adverse cardiovascular events occurred at 30 days. Compared to the GuardWire, the use of the FilterWire was associated with more microembolic signals during stent deployment (77.4+/-33.5 versus 1.07+/-1.94, p<0.0001), postdilation (63.9+/-21.0 versus 2.06+/-2.58, p<0.0001), and retrieval of the protection device (21.4+/-15.4 versus 10.9+/-8.3, p=0.051). Consequently, the total amount of microembolic signals during the procedure was higher when the filter device was employed (183.0+/-42.1 versus 31.7+/-12.0, p<0.0001). The distal occlusion device appears to be more effective than the filter in reducing distal embolization detected by transcranial Doppler monitoring.
NASA Astrophysics Data System (ADS)
Schindlbeck, J. C.; Kutterolf, S.; Hemming, S. R.; Wang, K. L.
2015-12-01
Including the recently drilled CRISP sites (IODP Exp. 334&344) the deep sea drilling programs have produced 69 drill holes at 29 Sites during 9 Legs at the Central American convergent margin, where the Cocos plate subducts beneath the Caribbean plate. The CAVA produced numerous plinian eruptions in the past. Although abundant in the marine sediments, information and data regarding large late Cenozoic explosive eruptions from Costa Rica, Nicaragua, Honduras, El Salvador, and Guatemala remain very sparse and discontinuous on land. We have established a tephrostratigraphy from recent through Miocene times from the unique archive of ODP/IODP sites offshore Central America in which we identify tephra source regions by geochemical fingerprinting using major and trace element glass shard compositions. Here we present first order correlations of ~500 tephra layers between multiple holes at a single site as well as between multiple sites. We identified ashes supporting Costa Rican (~130), Nicaraguan (17) and Guatemalan (27) sources as well as ~150 tephra layers from the Galápagos hotspot. Within our marine record we also identified well-known marker beds such as the Los Chocoyos tephra from Atitlán Caldera in Guatemala and the Tiribi Tuff from Costa Rica but also correlations to 15 distinct deposits from known Costa Rican and Nicaraguan eruptions within the last 4.1 Ma. These correlations, together with new radiometric age dates, provide the base for an improved tephrochronostratigraphy in this region. Finally, the new marine record of explosive volcanism offshore southern CAVA provides insights into the eruptive history of long-living volcanic complexes (e.g., Barva, Costa Rica) and into the distribution and frequency of large explosive eruptions from the Galápagos hotspot. The integrated approach of Ar/Ar age dating, correlations with on land deposits from CAVA, biostratigraphic ages and sediment accumulation rates improved the age models for the drilling sites.
Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.
Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech
2016-06-01
Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.
Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy
Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.
2004-01-01
Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular reconstructions were patent at last follow-up. With median follow-up of 26 months, 5 patients have died of recurrent malignancy at 44, 40, 32, 26, and 24 months, while an additional patient is alive with disease at 31 months. Actuarial 1-, 3-, and 5-year survivals were 85%, 60%, and 33%, respectively. Conclusions: IVC involvement by hepatic malignancy does not necessarily preclude resection. Liver resection with reconstruction of the inferior vena cava can be performed in selected cases. The increased risk associated with the procedure appears to be balanced by the possible benefits, particularly when the lack of alternative curative approaches is considered. PMID:15082976
Kalman filter-based EM-optical sensor fusion for needle deflection estimation.
Jiang, Baichuan; Gao, Wenpeng; Kacher, Daniel; Nevo, Erez; Fetics, Barry; Lee, Thomas C; Jayender, Jagadeesan
2018-04-01
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle's tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects. In this paper, measurements data from an optical sensor at the needle base and a magnetic resonance (MR) gradient field-driven electromagnetic (EM) sensor placed 10 cm from the needle tip are used within a model-integrated Kalman filter-based sensor fusion scheme. Bending model-based estimations and EM-based direct estimation are used as the measurement vectors in the Kalman filter, thus establishing an online estimation approach. Static tip bending experiments show that the fusion method can reduce the mean error of the tip position estimation from 29.23 mm of the optical sensor-based approach to 3.15 mm of the fusion-based approach and from 39.96 to 6.90 mm, at the MRI isocenter and the MRI entrance, respectively. This work established a novel sensor fusion scheme that incorporates model information, which enables real-time tracking of needle deflection with MRI compatibility, in a free-hand operating setup.
Kaoutzanis, Christodoulos; Evangelakis, Erotokritos; Kokkinos, Chrysostomos; Kaoutzanis, Gavriel
2011-01-01
Traumatic injury to the retrohepatic veins continues to carry high mortality rates. In the last few decades various management strategies have been proposed. However, treatment of such injuries still remains highly variable and technically challenging due to the surgically inaccessible location of these vessels and the consequent difficulty controlling bleeding. We report a successful repair of complete transection of the two main extraparenchymal hepatic veins and laceration of the retrohepatic inferior vena cava using cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA) following blunt abdominal trauma. Immediate CPB with or without HCA can be life-saving and should be considered for patients with complex isolated retrohepatic venous injuries.
Harbuzova, V Iu
2002-01-01
The intensity of the lipid peroxydation (LPO) and the antioxidant enzyme activity (superoxide dismutase, glutathione peroxydase and catalase) on injecting vitamin D in high doses (10,000 U/kg) was examined in the arterial and venous walls of rabbits. The increase in the amount of the intermediate and final LPO products has been found in the vessels of all types. The lowest intensity of LPO was noted in the vena cava. The decrease in the antioxidant activity has been revealed. But vena cava inferior was the exception because the activity of all studied antioxidant enzymes grew in its wall. This increase is likely to be one of the reasons for vena resistance to the action of damaging factors.
Physiologic Effect of Stent Therapy for Inferior Vena Cava Obstruction Due to Malignant Liver Tumor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kishi, Kazushi; Sonomura, Tetsuo; Fujimoto, Hisashi
Purpose. To understand systemic the influence of stent therapy for inferior vena cava (IVC) obstruction due to advanced liver tumor. Methods. Seven patients with symptomatic IVC obstruction due to advanced primary (n 4) or secondary (n = 3) liver tumor were subjected to stent therapy. Enrollment criteria included high IVC pressure over 15 mmHg and the presence of edema and ascites. Z-stents were deployed using coaxial sheath technique via femoral venous puncture. Physiologic and hematobiochemical parameters were analyzed. Results. All procedures were successful, and the stents remained patent until patient death. Promptly after stent placement, the IVC flow recovered, andmore » the venous blood pressure in the IVC below the obstruction level showed a significant decrease from 20.8 {+-} 1.2 mmHg (mean {+-} SE) to 10.7 {+-} 0.7 mmHg (p < 0.01). Transient mild increase of right atrial pressure was observed in 1 patient. During the following week prominent diuresis was observed in all patients. Mean urine output volume in the 3 days before the stent therapy was 0.81 {+-} 0.09 l/day compared with 2.1 {+-} 0.2 l/day (p < 0.01) in the 3 days after. The edema and ascites decreased in all patients. The caval pressure change correlated well (r > 0.6) with the urine volume increase, and with the decreased volume of edema and ascites. The urine volume increase correlated well with the decrement of edema, but not with that of ascites. Improvements for various durations in the levels of blood urea nitrogen, serum creatinine, lactate dehydrogenase, fibrinogen, and platelet count were found (p < 0.05). These hematobiochemical changes were well correlated with each other and with the decrement of ascites. Two patients showed a low blood sodium level of 128.5 mEq/l after intensive natriuresis, and one of them died on day 21 with hepatic failure, which was interpreted as maladaptation aggravation. The mean survival time was 94.1 {+-} 34.1 days (mean {+-} SD), ranging from 21 to 140 days after stent treatment. Conclusion. The stent therapy for IVC obstruction due to malignant liver tumors was followed by a series of physiologic and hematobiochemical consequences, most of them favorable but some possibly unfavorable. Rational interpretations and predictions of sequelae based on physiologic science including cardiology, hepatology, and nephrology would facilitate the best management of stent therapy for malignant IVC obstruction.« less