Sample records for cava ivc diameter

  1. Computational Simulations of Inferior Vena Cava (IVC) Filter Placement and Hemodynamics in Patient-Specific Geometries

    NASA Astrophysics Data System (ADS)

    Aycock, Kenneth; Sastry, Shankar; Kim, Jibum; Shontz, Suzanne; Campbell, Robert; Manning, Keefe; Lynch, Frank; Craven, Brent

    2013-11-01

    A computational methodology for simulating inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and tested on two patient-specific IVC geometries: a left-sided IVC, and an IVC with a retroaortic left renal vein. Virtual IVC filter placement was performed with finite element analysis (FEA) using non-linear material models and contact modeling, yielding maximum vein displacements of approximately 10% of the IVC diameters. Blood flow was then simulated using computational fluid dynamics (CFD) with four cases for each patient IVC: 1) an IVC only, 2) an IVC with a placed filter, 3) an IVC with a placed filter and a model embolus, all at resting flow conditions, and 4) an IVC with a placed filter and a model embolus at exercise flow conditions. Significant hemodynamic differences were observed between the two patient IVCs, with the development of a right-sided jet (all cases) and a larger stagnation region (cases 3-4) in the left-sided IVC. These results support further investigation of the effects of IVC filter placement on a patient-specific basis.

  2. Estimation and tracking of AP-diameter of the inferior vena cava in ultrasound images using a novel active circle algorithm.

    PubMed

    Karami, Ebrahim; Shehata, Mohamed S; Smith, Andrew

    2018-05-04

    Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Flat inferior vena cava: indicator of poor prognosis in trauma and acute care surgery patients.

    PubMed

    Ferrada, Paula; Vanguri, Poornima; Anand, Rahul J; Whelan, James; Duane, Therese; Wolfe, Luke; Ivatury, Rao

    2012-12-01

    Flat inferior vena cava (IVC) on ultrasound examination has been shown to correlate with hypovolemic status. We hypothesize that a flat IVC on limited echocardiogram (LTTE) performed in the emergency room (ER) correlates with poor prognosis in acutely ill surgical patients. We conducted a retrospective review of all patients undergoing LTTE in the ER from September 2010 until June 2011. IVC diameter was estimated by subxiphoid window. Flat IVC was defined as diameter less than 2 cm. Fat IVC was defined as diameter greater than 2 cm. Need for intensive care unit admission, blood transfusion requirement, mortality, and need for emergent operation between patients with flat versus Fat IVC were compared. One hundred one hypotensive patients had LTTE performed in the ER. Average age was 38 years. Admission diagnosis was blunt trauma (n = 80), penetrating trauma (n = 13), acute care surgery pathology (n = 7), and burn (n = 1). Seventy-four patients had flat IVC on initial LTTE. Compared with those with fat IVC, flat patients were found have higher rates of intensive care unit admission (51.3 vs 14.8%; P = 0.001), blood transfusion requirement (12.2 vs 3.7%), and mortality (13.5 vs 3.7%). This population also underwent emergent surgery on hospital Day 1 more often (16.2 vs 0%; P = 0.033). Initial flat IVC on LTTE is an indicator of hypovolemia and a predictor of poor outcome.

  4. Renal cell carcinoma with venous extension: prediction of inferior vena cava wall invasion by MRI.

    PubMed

    Adams, Lisa C; Ralla, Bernhard; Bender, Yi-Na Y; Bressem, Keno; Hamm, Bernd; Busch, Jonas; Fuller, Florian; Makowski, Marcus R

    2018-05-03

    Renal cell carcinoma (RCC) are accompanied by inferior vena cava (IVC) thrombus in up to 10% of the cases, with surgical resection remaining the only curative option. In case of IVC wall invasion, the operative procedure is more challenging and may even require IVC resection. This study aims to determine the diagnostic performance of contrast-enhanced magnetic resonance imaging (MRI) for the assessment of wall invasion by IVC thrombus in patients with RCC, validated with intraoperative findings. Data were collected on 81 patients with RCC and IVC thrombus, who received a radical nephrectomy and vena cava thrombectomy between February 2008 and November 2017. Forty eight patients met the inclusion criteria. Sensitivity and specificity as well as the positive and negative predictive values were calculated for preoperative MRI, based on the assessments of the two readers for visual wall invasion. Furthermore, a logistic regression model was used to determine if there was an association between intraoperative wall adherence and IVC diameter. Complete occlusion of the IVC lumen or vessel breach could reliably assess IVC wall invasion with a sensitivity of 92.3% (95%-CI: 0.75-0.99) and a specificity of 86.4% (95%-CI: 0.65-0.97) (Fisher-test: p-value< 0.001). The positive predictive value (PPV) was 88.9% (95%-CI: 0.71-0.98) and the negative predictive value reached 90.5% (95%-CI: 0.70-0.99). There was an excellent interobserver agreement for determining IVC wall invasion with a kappa coefficient of 0.90 (95%CI: 0.79-1.00). The present study indicates that standard preoperative MR imaging can be used to reliably assess IVC wall invasion, evaluating morphologic features such as the complete occlusion of the IVC lumen or vessel breach. Increases in IVC diameter are associated with a higher probability of IVC wall invasion.

  5. [Leiomyosarcoma of the inferior vena cava: a case report and review].

    PubMed

    Yo, Toeki; Taoka, Rikiya; Hanasaki, Takeshi; Nakanishi, Yukako; Togo, Yoshikazu; Suzuki, Toru; Higuchi, Yoshihide; Zozumi, Masataka; Hirota, Seiichi; Kanematsu, Akihiro; Nojima, Michio; Yamamoto, Shingo

    2014-03-01

    A 37-year-old woman with an incidentally found abdominal mass was referred to our hospital. A fixed, non-tender mass was palpated in the right upper quadrum of her abdomen. There was no elevation of tumor markers. Computed tomography revealed a mass extending from the hepatic vein level to renal hilar level. The tumor completely obstructed the inferior vena cava (IVC). T1-weighted magnetic resonance imaging (MRI) showed that the mass was isointense with muscles. T2-weighted MRI image with contrast medium demonstrated collateral circulation. Upon diagnosis of the IVC tumor, we removed the right kidney and the tumor en bloc without reconstructing IVC. The tumor diameter was 11.6 × 5.5 × 4.7 cm. Pathological examination established a diagnosis of IVC leiomyosarcoma. She is alive without sign of recurrence after operation for seven months. There were 143 reports of IVC leiomyosarcoma in Japan. In 31% of them, IVC was not reconstructed.

  6. Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration.

    PubMed

    Chen, Lei; Kim, Yunie; Santucci, Karen A

    2007-10-01

    Bedside ultrasonography (US) measurement of the inferior vena cava (IVC) and aorta (Ao) may be useful in objectively assessing children with dehydration. The objectives of this study were 1) to compare the IVC and Ao diameters (IVC/Ao) ratio of dehydrated children with controls and 2) to compare the IVC/Ao ratio before and after intravenous (i.v.) rehydration in children with dehydration. This prospective observational study was performed in an urban pediatric emergency department. Children between 6 months and 16 years of age with clinical evidence of dehydration were enrolled. Bedside US measurements of the IVC and Ao were taken before and immediately after i.v. fluids were administered. An age-, gender-, and weight-matched control without dehydration was enrolled for each subject. The IVC/Ao ratios of subjects and controls were compared using Wilcoxon signed rank test, as were the ratios before and after i.v. hydration for each subject. Thirty-six pairs of subjects and matched controls were enrolled. The IVC/Ao ratios in the subjects were lower as compared with controls (mean of 0.75 vs. 1.01), with a mean difference of 0.26 (95% confidence interval = 0.18 to 0.35). In subjects, the IVC/Ao ratios were significantly lower before i.v. hydration (mean of 0.75 vs. 1.09), with a mean difference of 0.34 (95% confidence interval = 0.29 to 0.39). As measured by bedside US measurement, the IVC/Ao ratio is lower in children clinically assessed to be dehydrated. Furthermore, it increases with administration of i.v. fluid boluses.

  7. Chemoembolization and stenting combined with iodine-125 seed strands for the treatment of hepatocellular carcinoma with inferior vena cava obstruction

    PubMed Central

    LI, WENHUI; DAI, ZHENYU; YAO, LIZHENG; LUO, JIANJUN; YAN, ZHIPING

    2015-01-01

    The aim of the present study was to investigate the efficacy and safety of stenting combined with radioactive iodine-125 seed strands following chemoembolization for the treatment of patients with hepatocellular carcinoma and inferior vena cava (IVC) obstruction. A retrospective analysis was conducted of 52 hepatocellular carcinoma patients with IVC obstruction. All patients received chemoembolization of tumor-supplying arteries and IVC stents, and 18 patients additionally received iodine-125 seed strands, which were fixed to the stents. Improvement of IVC obstruction and the tumor response rates were compared between the two groups with a median follow-up time of 2.5 months. In both groups the stents were successfully deployed. At the 2-month post-procedural follow-up, the mean diameter of the IVC obstruction site, the mean pressure difference between the distal IVC obstructive segment and the right atrium as well as the obstruction scoring did not differ significantly between the two groups. By contrast, the tumor response rate of the iodine-125 seed strand group was 94.4%, whereas for the group without iodine-125 seed strands it was 35.3% (P<0.001). The combination of stent and iodine-125 seed strands was effective and safe for the treatment of hepatocellular carcinoma with IVC obstruction. PMID:26622424

  8. A Retrospective Evaluation of Echocardiograms to Establish Normative Inferior Vena Cava and Aortic Measurements for Children Younger Than 6 Years.

    PubMed

    Stenson, Erin K; Punn, Rajesh; Ramsi, Musaab; Kache, Saraswati

    2018-02-26

    The ability to plot the inferior vena cava (IVC) size on a normal curve for pediatric patients may prove beneficial. First, in patients with normal cardiac anatomy who present in shock, assessing IVC size may be valuable for evaluating the degree of dehydration. Second, in children with heart disease, understanding how a child's IVC size compares to normal could be particularly beneficial for patients with right heart disease. We sought to create normal curves for the IVC and aorta in children younger than 6 years. Data were gathered from 347 echocardiograms of healthy children younger than 6 years in a retrospective study at a quaternary care children's hospital. From the subcostal long- and short-axis images, maximum diameters in the transverse and longitudinal views were obtained for both the IVC and the aorta. Both IVC and aortic dimensions increased in a linear fashion and had excellent correlations with the body surface area, body mass, and height (IVC, r = 0.78-0.81; P < .0001; aorta, r = 0.82-0.86; P < .0001). In children younger than 6 years, the IVC and aorta increase linearly as the children grow. Such normal curves will be beneficial for assessing a pediatric patient's hydration status or right heart function in patients with congenital heart disease. © 2018 by the American Institute of Ultrasound in Medicine.

  9. Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters.

    PubMed

    Charbonneau, Hélène; Riu, Béatrice; Faron, Matthieu; Mari, Arnaud; Kurrek, Matt M; Ruiz, Jean; Geeraerts, Thomas; Fourcade, Olivier; Genestal, Michèle; Silva, Stein

    2014-09-05

    Echocardiographic indices based on respiratory variations of superior and inferior vena cavae diameters (ΔSVC and ΔIVC, respectively) have been proposed as predictors of fluid responsiveness in mechanically ventilated patients, but they have never been compared simultaneously in the same patient sample. The aim of this study was to compare the predictive value of these echocardiographic indices when concomitantly recorded in mechanically ventilated septic patients. Septic shock patients requiring hemodynamic monitoring were prospectively enrolled over a 1-year period in a mixed medical surgical ICU of a university teaching hospital (Toulouse, France). All patients were mechanically ventilated. Predictive indices were obtained by transesophageal and transthoracic echocardiography and were calculated as follows: (Dmax - Dmin)/Dmax for ΔSVC and (Dmax - Dmin)/Dmin for ΔIVC, where Dmax and Dmin are the maximal and minimal diameters of SVC and IVC. Measurements were performed at baseline and after a 7-ml/kg volume expansion using a plasma expander. Patients were separated into responders (increase in cardiac index ≥15%) and nonresponders (increase in cardiac index <15%). Among 44 included patients, 26 (59%) patients were responders (R). ΔSVC was significantly more accurate than ΔIVC in predicting fluid responsiveness. The areas under the receiver operating characteristic curves for ΔSVC and ΔIVC regarding assessment of fluid responsiveness were significantly different (0.74 (95% confidence interval (CI): 0.59 to 0.88) and 0.43 (95% CI: 0.25 to 0.61), respectively (P = 0.012)). No significant correlation between ΔSVC and ΔIVC was found (r = 0.005, P = 0.98). The best threshold values for discriminating R from NR was 29% for ΔSVC, with 54% sensitivity and 89% specificity, and 21% for ΔIVC, with 38% sensitivity and 61% specificity. ΔSVC was better than ΔIVC in predicting fluid responsiveness in our cohort. It is worth noting that the sensitivity and specificity values of ΔSVC and ΔIVC for predicting fluid responsiveness were lower than those reported in the literature, highlighting the limits of using these indices in a heterogeneous sample of medical and surgical septic patients.

  10. Ultrasound measurement of inferior vena cava diameters by emergency department nurses.

    PubMed

    De Lorenzo, Robert A; Holbrook-Emmons, Victoria L

    2014-01-01

    Sonographic measurement of the inferior vena cava (IVC) diameter is a potentially important noninvasive estimate of fluid status. We researched whether nurses without prior ultrasonography experience could accurately obtain vena cava diameter measurements on models and subjects in comparison with those obtained by an expert sonographer. The design was a prospective educational study using a pre- and posttest of knowledge and a comparison of imaging performance between a subject and an expert sonographer. The setting was an urban teaching medical center with emergency nurses and a convenience sample of volunteer patients selected from the emergency department (ED). Nurses completed a written survey and a pretest to document prior training and experience in ultrasonography and assess baseline knowledge. A structured training program (3.5 hr in length) was provided over three sessions. Training consisted of didactic presentations, practice on phantoms (manikin models designed to provide the sonographic image of the human body when scanned by a trainee) and classmates, and one volunteer patient in the ED. Each nurse then measured IVC diameters on three different volunteer patients in transverse and longitudinal orientations using frozen images. An expert sonographer, blinded to subject results, performed the same examination. Correlations were determined, and a posttraining written examination was completed and results compared with the pretest using a pair-wise t test. Fourteen nurses, with a mean of 8 years' nursing experience (range = 2-18 years), participated. Nurse-expert R value correlation for the longitudinal orientation was 0.68 (95% confidence interval [CI] [0.35, 0.76]) and 0.59 (95% CI [0.47, 0.81]) for the transverse orientation. Posttest scores improved 8.2 percentage points (95% CI [4.0, 12.4]) from 83.3% to 91.5%. Following a brief training course, nurses with no prior sonography experience show moderately good correlation measuring the IVC diameter as compared with expert measurements, with better performance demonstrated in the longitudinal orientation.

  11. A rare congenital extrahepatic portosystemic shunt affecting the inferior mesenteric vein, inferior vena cava, and left ovarian vein.

    PubMed

    Takeuchi, Hajime; Takeda, Yoko; Takahashi, Miyo; Hayashi, Shogo; Fukuzawa, Yoshitaka; Nakano, Takashi

    2014-09-01

    To observe a case of congenital extrahepatic portosystemic shunt and discuss it from the embryological and clinical viewpoints. An 85-year-old female cadaver was employed for a dissection course at Aichi Medical University in 2009. There was no evidence of liver cirrhosis macroscopically or microscopically. A portosystemic shunt was observed that involved communication between the inferior mesenteric vein, inferior vena cava (IVC), and left ovarian vein by a single Y-shaped shunt vessel. To the best of our knowledge, this is the first reported case of the above-mentioned three veins being connected by a single Y-shaped shunt vessel. Considering the other venous diameters, the shunt appeared to flow into the splenic vein and IVC. It cannot be denied that this shunt may have led to hepatic encephalopathy, although the shunt effect may have been minimal. Embryological development of IVC appears to occur close to the plexus of anastomosing vitelline veins, forming the portal vein.

  12. Complications of Celect, Günther tulip, and Greenfield inferior vena cava filters on CT follow-up: a single-institution experience.

    PubMed

    McLoney, Eric D; Krishnasamy, Venkatesh P; Castle, Jordan C; Yang, Xiangyu; Guy, Gregory

    2013-11-01

    To evaluate and compare the rates of complications on follow-up computed tomography (CT) studies of patients with Celect, Günther Tulip, and Greenfield inferior vena cava (IVC) filters. Retrospective review of CT studies obtained 0-1,987 days after infrarenal placement of an IVC filter identified 255 Celect, 160 Tulip, and 50 Greenfield filters. Follow-up CT studies were independently evaluated by two observers for IVC perforation, contact with adjacent organs, and filter fracture. Multivariate analysis was performed to identify factors associated with higher rates of IVC perforation, including age, IVC diameter, sex, and history of malignancy. IVC perforation was observed in 126 of 255 Celect filters (49%) with a mean follow-up of 277 days, 69 of 160 Tulip filters (43%) with a mean follow-up of 437 days, and one of 50 Greenfield filters (2%) with a mean follow-up of 286 days. A significantly higher IVC perforation rate was observed in women (45.5%) compared with men (30.8%; P = .002) and in patients with a history of malignancy (43.7%) compared with patients with no history of malignancy (29.9%; P < .001). Filter fracture was rare, observed in two of 255 Celect filters (0.8%), one of 160 Tulip filters (0.6%), and none of 50 Greenfield filters. No significant difference was observed in IVC perforation rate between Celect and Tulip filters. Greenfield filters had a significantly lower rate of IVC perforation than Celect and Tulip filters. Higher IVC perforation rates were observed in women and patients with a history of malignancy. © SIR, 2013.

  13. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    PubMed

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  14. Differences in radial expansion force among inferior vena cava filter models support documented perforation rates.

    PubMed

    Robins, J Eli; Ragai, Ihab; Yamaguchi, Dean J

    2018-05-01

    Inferior vena cava (IVC) filters are used in patients at risk for pulmonary embolism who cannot be anticoagulated. Unfortunately, these filters are not without risk, and complications include perforation, migration, and filter fracture. The most prevalent complication is filter perforation of the IVC, with incidence varying among filter models. To our knowledge, the mechanical properties of IVC filters have not been evaluated and are not readily available through the manufacturer. This study sought to determine whether differences in mechanical properties are similar to differences in documented perforation rates. The radial expansion forces of Greenfield (Boston Scientific, Marlborough, Mass), Cook Celect (Cook Medical, Bloomington, Ind), and Cook Platinum filters were analyzed with three replicates per group. The intrinsic force exerted by the filter on the measuring device was collected in real time during controlled expansion. Replicates were averaged and significance was determined by calculating analysis of covariance using SAS software (SAS Institute, Cary, NC). Each filter model generated a significantly different radial expansion force (P < .001), and force was distributed at significantly different rates (P < .001) during expansion. The largest radial expansion force at minimal caval diameter was seen in the Cook Platinum filter, followed by the Cook Celect and Greenfield filters. Radial force dispersion during expansion was greatest in the Cook Celect, followed by the Cook Platinum and Greenfield filters. Differences in radial expansion forces among IVC filter models are consistent with documented perforation rates. Cook Celect IVC filters have a higher incidence of perforation compared with Greenfield filters when they are left in place for >90 days. Evaluation of Cook Celect filters yielded a significantly higher radial expansion force at minimum caval diameter, with greater force dispersion during expansion. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Vena cava thrombectomy and primary repair after radical nephrectomy for renal cell carcinoma: single-center experience.

    PubMed

    Helfand, Brian T; Smith, Norm D; Kozlowski, James M; Eskandari, Mark K

    2011-01-01

    Inferior vena cava (IVC) reconstruction for locally advanced renal cell carcinoma (RCC) includes resection with and without interposition grafting, patch graft, or primary repair. The proposed benefits of lateral venorrhaphy and primary repair are avoidance of foreign material, a more expeditious repair, and preservation of lower extremity venous outflow. A single-center retrospective review of 22 patients with RCC and IVC tumor thrombus treated with radical nephrectomy, lateral venorrhaphy, thrombectomy, and primary vena cava repair between July 2002 and June 2009 was carried out. Demographic data, diagnostic information, radiographic cross-sectional imaging, and procedural outcomes were examined. Among the 13 men and nine women, the mean age was 62.1 years (42-83); mean tumor size was 9.8 cm (3-17 cm), and 90% (n = 18) of the cases with RCC were identified pathologically as clear cell adenocarcinoma; on the basis of the classification system adopted by Neves, level I was for 50% (n = 11), level II for 32% (n = 7), level III for 9% (n = 2), and level IV for 9% (n = 2) of the patients. All patients underwent en bloc radical nephrectomy with tumor thrombus removal and primary IVC repair. Mean total operative time was 547.9 ± 138.5 minutes, whereas mean IVC cross-clamp time was 10.8 minutes (6-29 minutes). There were no intraoperative deaths or pulmonary embolism and all IVC margins were found to be pathologically negative. Postoperative complications included one pulmonary embolism, one exacerbation of chronic lymphedema, and two cases of new onset erectile dysfunction. Mean follow-up was 36.4 ± 23.2 months (6-92 months). There were no radiographic or clinically significant changes in mean IVC diameter during follow-up. Five late deaths (23%) occurred as a result of metastatic RCC over a mean period of 24 months (range, 12-48), but without any local recurrences. For advanced RCC with tumor thrombus extension into the IVC, lateral venorrhaphy and primary IVC repair avoids complicated caval reconstructions and results in high patency rates with a low local tumor recurrence rate. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  16. Prognostic significance of dilated inferior vena cava in advanced decompensated heart failure.

    PubMed

    Lee, Hsin-Fu; Hsu, Lung-An; Chang, Chi-Jen; Chan, Yi-Hsin; Wang, Chun-Li; Ho, Wan-Jing; Chu, Pao-Hsien

    2014-10-01

    Dilated inferior vena cava (IVC) is prevalent among patients with heart failure (HF), but whether its presence predicts worsening renal function (WRF) or adverse outcomes is unclear. This cohort study analyzed patients with left ventricular ejection fraction <40 % and repeated hospitalizations (≥2 times) for HF between August 2009 and August 2011. The study endpoints were death and HF re-hospitalization. Among baseline parameters, IVC diameter was the most powerful predictor for the development of WRF (area under the curve = 0.795, cut-off value = 20.5 mm). During the 2-year follow-up, 36 patients (49 %) were re-hospitalized for HF and 14 patients (19 %) died. The event rates were significantly greater in the WRF group than in the non-WRF group (71 vs. 30 %, P < 0.001 for HF re-hospitalization; 29 vs. 10 %, P = 0.03 for death). In Cox regression model, the risk of combined end-points was increased in patients with aging, elevated blood urine nitrogen, IVC >21 mm, and WRF. When adjusted for confounding factors, IVC >21 mm [hazard ratio (HR) 3.73, 95 % confidence interval (CI) 1.66-8.34] and WRF (HR 2.68, 95 % CI 1.07-6.75) were significant predictors for adverse outcomes. In patients with advanced decompensated HF, dilated IVC (>21 mm) predicted the development of WRF and could be a predictor for adverse outcomes.

  17. Prophylactic Placement of an Inferior Vena Cava Filter During Aspiration Thrombectomy for Acute Deep Venous Thrombosis of the Lower Extremity.

    PubMed

    Kwon, Se Hwan; Park, So Hyun; Oh, Joo Hyeong; Song, Myung Gyu; Seo, Tae-Seok

    2016-05-01

    To evaluate the effect of an inferior vena cava (IVC) filter during aspiration thrombectomy for acute deep vein thrombosis (DVT) in the lower extremity. From July 2004 to December 2013, a retrospective analysis of 106 patients with acute DVT was performed. All patients received an IVC filter and were treated initially with aspiration thrombectomy. Among the 106 patients, DVT extension into the IVC was noted in 27 but was not evident in 79. We evaluated the presence of trapped thrombi in the filters after the procedure. The sizes of the trapped thrombi were classified into 2 grades based on the ratio of the maximum transverse length of the trapped thrombus to the diameter of the IVC (Grades I [≤ 50%] and II [> 50%]). A trapped thrombus in the filter was detected in 46 (43%) of 106 patients on final venograms. The sizes of the trapped thrombi were grade I in 12 (26.1%) patients and grade II in 34 (73.9%). Among the 27 patients with DVT extension into the IVC, 20 (74.1%) showed a trapped thrombus in the filter, 75% (15 of 20) of which were grade II. Among the 79 patients without DVT extension into the IVC, 26 (32.9%) showed a trapped thrombus in the IVC filter, 73% (19 of 26) of which were grade II. Thrombus migration occurred frequently during aspiration thrombectomy of patients with acute DVT in the lower extremity. However, further studies are needed to establish a standard protocol for the prophylactic placement of an IVC filter during aspiration thrombectomy. © The Author(s) 2016.

  18. Procedural and Indwelling Complications with Inferior Vena Cava Filters: Frequency, Etiology, and Management

    PubMed Central

    Milovanovic, Lazar; Kennedy, Sean A.; Midia, Mehran

    2015-01-01

    Inferior vena cava (IVC) filters are commonly used in select high-risk patients for the prevention of pulmonary embolism. Potentially serious complications can arise from the use of IVC filters, including thrombosis of the filter itself and filter fragment embolization. This article discusses the utility of IVC filters and reviews the management of two cases of filter-related complications. PMID:25762846

  19. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  20. Inferior Vena Cava Filter Placement and Removal

    MedlinePlus

    ... Professions Site Index A-Z Inferior Vena Cava Filter Placement and Removal During Inferior Vena Cava (IVC) ... benefits vs. risks? What is Inferior Vena Cava Filter Placement and Removal? In an inferior vena cava ...

  1. Successful balloon dilatation for postoperative caval stenosis caused by primary venorrhaphy for traumatic retro-hepatic caval injury in a three-year-old child: Report of a case.

    PubMed

    Masui, Daisuke; Iinuma, Yasushi; Hirayama, Yutaka; Nitta, Kohju; Iida, Hisataka; Otani, Tetsuya; Yokoyama, Naoyuki; Sato, Seiichi; Numano, Fujito; Yagi, Minoru

    2015-09-01

    Inferior vena cava injuries are highly lethal. We experienced a case of retrohepatic inferior vena cava injury as a result of blunt trauma in a three-year-old female. Because the site of bleeding of the IVC was identified, we repaired it with running sutures. An attempt at primary repair resulted in postoperative narrowing of the vena cava. There was pressure gradient of the right atrium and inferior vena cava, and collateral circulation developed. Since it was also found that the haemodynamics was unstable, the child underwent another intervention before the stenosis of the IVC was fixed. To the best of our knowledge, there have been no previous reports of therapeutic radiological intervention for stenosis that developed after treatment of a traumatic IVC injury. The IVC in the present case recovered enough patency so that the collateral venous flow could be decreased after balloon dilatation angioplasty. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Inferior vena cava filters.

    PubMed

    Duffett, L; Carrier, M

    2017-01-01

    Use of inferior vena cava (IVC) filters has increased dramatically in recent decades, despite a lack of evidence that their use has impacted venous thromboembolism (VTE)-related mortality. This increased use appears to be primarily driven by the insertion of retrievable filters for prophylactic indications. A growing body of evidence, however, suggests that IVC filters are frequently associated with clinically important adverse events, prompting a closer look at their role. We sought to narratively review the current evidence on the efficacy and safety of IVC filter placements. Inferior vena cava filters remain the only treatment option for patients with an acute (within 2-4 weeks) proximal deep vein thrombosis (DVT) or pulmonary embolism and an absolute contraindication to anticoagulation. In such patients, anticoagulation should be resumed and IVC filters removed as soon as the contraindication has passed. For all other indications, there is insufficient evidence to support the use of IVC filters and high-quality trials are required. In patients where an IVC filter remains, regular follow-up to reassess removal and screen for filter-related complications should occur. © 2016 International Society on Thrombosis and Haemostasis.

  3. Patients with inferior vena cava thrombosis frequently present with lower back pain and bilateral lower-extremity deep vein thrombosis.

    PubMed

    Kraft, Christiane; Hecking, Carola; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit

    2013-07-01

    Inferior vena cava (IVC) thrombosis is rare, and data about the clinical presentation of patients are scarce. Therefore, we reviewed all cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described patients’ characteristics in terms of their clinical presentations in the acute setting of IVC thrombosis. From the MAISTHRO registry, which enrolled 1470 consecutive patients with documented histories of venous thromboembolism, we identified 60 patients (0,4 %; females 60 %) with IVC thrombosis and 888 patients (60.4 %; females 55 %) with isolated lower-extremity deep vein thrombosis (LE-DVT). The median age at the time of IVC thrombosis manifestation was 36.5 years (9 to 83). IVC thrombosis was the initial VTE event in 47 patients (78 %). In the majority of cases, IVC thrombosis extended to the lower-extremity veins, and both lower extremities were affected in 17 cases (28 %). The initial clinical symptom of IVC thrombosis was lower back or abdominal pain which preceded typical symptoms of LE-DVT in 29 (48 %) patients. Symptomatic pulmonary embolism was more frequently observed in IVC thrombosis patients when compared to a sex- and age-matched subgroup of LE-DVT patients, although the difference was not significant (27 % vs. 12 %; p = 0.064). Malignant disease was the only established VTE risk factor with a higher prevalence among IVC thrombosis patients than patients with isolated LE-DVT (27 % vs. 9 %; p = 0.015). Congenital IVC anomalies were identified in another eight IVC thrombosis patients (13 %). IVC thrombosis should be considered a differential diagnosis for inexplicable lower back or abdominal pain especially in young patients. Malignant disease and congenital IVC anomalies seem to be predisposing factors for thrombosis involving the inferior vena cava.

  4. Atrophic inferior vena cava is a marker of chronicity of intra-filter and inferior vena cava thrombosis: based on CT findings.

    PubMed

    Chen, Liang; Shi, Wanyin; Gu, Jianping; He, Xu; Lou, Wensheng

    2018-04-11

    A permanently indwelling filter in the inferior vena cava (IVC) may induce caval thrombosis, which could develop and evolve from an acute to a chronic phase. The differential diagnosis of acute and chronic thromboses determines the treatment strategy. The role of computed tomography (CT) in diagnosing acute and chronic intra-filter and IVC thromboses has not been well established. This retrospective study summarizes the CT signs that indicate acute and chronic phases of intra-filter and IVC thromboses. This study included eight patients who developed a lower-extremity deep venous thrombosis (DVT) and were treated with intracaval filter placement as an alternative to anticoagulation and thrombolysis. During the follow-up, all patients developed an intra-filter thrombosis in the IVC confirmed by CT and/or CT venography (CTV). Demographic and CT data of all patients during the follow-up period were collected for analysis. All patients had normal-appearing IVCs prior to filter placement, as shown on trans-femoral venography. Eight filters (five TrapEase, three OptEase) were placed in the eight IVCs, respectively. Subsequently, IVC-CT or CTV revealed acute intra-filter or IVC thrombosis in all eight patients, manifesting as an intracaval filling defect and thickened IVC wall. Filter protrusion and secondary caval atrophy seen on CT indicated a chronically occluded IVC. IVC thrombosis may result from filter placement. The chronicity of caval thrombotic occlusion is likely to be associated with filter protrusion and secondary IVC atrophy revealed on CT scans.

  5. Hospitalists' ability to use hand-carried ultrasound for central venous pressure estimation after a brief training intervention: a pilot study.

    PubMed

    Martin, L David; Ziegelstein, Roy C; Howell, Eric E; Martire, Carol; Hellmann, David B; Hirsch, Glenn A

    2013-12-01

    Access to hand-carried ultrasound technology for noncardiologists has increased significantly, yet development and evaluation of training programs are limited. We studied a focused program to teach hospitalists image acquisition of inferior vena cava (IVC) diameter and IVC collapsibility index with interpretation of estimated central venous pressure (CVP). Ten hospitalists completed an online educational module prior to attending a 1-day in-person training session that included directly supervised IVC imaging on volunteer subjects. In addition to making quantitative assessments, hospitalists were also asked to visually assess whether the IVC collapsed more than 50% during rapid inspiration or a sniff maneuver. Skills in image acquisition and interpretation were assessed immediately after training on volunteer patients and prerecorded images, and again on volunteer patients at least 6 weeks later. Eight of 10 hospitalists acquired adequate IVC images and interpreted them correctly on 5 of the 5 volunteer subjects and interpreted all 10 prerecorded images correctly at the end of the 1-day training session. At 7.4 ± 0.7 weeks (range, 6.9-8.6 weeks) follow-up, 9 of 10 hospitalists accurately acquired and interpreted all IVC images in 5 of 5 volunteers. Hospitalists were also able to accurately determine whether the IVC collapsibility index was more than 50% by visual assessment in 180 of 198 attempts (91% of the time). After a brief training program, hospitalists acquired adequate skills to perform and interpret hand-carried ultrasound IVC images and retained these skills in the near term. Though calculation of the IVC collapsibility index is more accurate, coupling a qualitative assessment with the IVC maximum diameter measurement may be acceptable in aiding bedside estimation of CVP. © 2013 Society of Hospital Medicine.

  6. Application of an Adaptive Control Grid Interpolation Technique to Morphological Vascular Reconstruction: A Component of a Comprehensive Surgical Planning and Evaluation Tool

    DTIC Science & Technology

    2001-10-25

    a lateral tunnel through the right atrium connecting the inferior vena cava with the RPA. The procedure results in a complete bypass of the right...IVC SVC RPA LPA SVC: superior vena cava IVC: inferior vena cava RPA: right pulmonary artery LPA: left pulmonary artery...Abstract – The total cavopulmonary connection (TCPC) is a palliative surgical repair performed on children with a single ventricle (SV

  7. The Effects of Adaptation to a Low Carbohydrate/High Fat Diet and Pre-Exercise Feeding on Exercise Endurance, Metabolism, and Cardiovascular Dynamics in Swine

    DTIC Science & Technology

    1988-01-01

    were obtained when initially (INITIAL) connected to the Inferior Vena Cava (IVC) or Hepatic Portal Vein (PV) catheters and just prior to feeding the...for metabolic measurements from the inferior vena cava (IVC) and the hepatic portal vein (PV) or for cardiovascular measurements (CV) from the...pulmonary artery and descending aorta with the ability to inject substances into the left atrium . Two pigs were initially instrumented for IVC and PV

  8. Use of a Trellis Device for Endovascular Treatment of Venous Thrombosis Involving a Duplicated Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saettele, Megan R., E-mail: SaetteleM@umkc.edu; Morelli, John N., E-mail: dr.john.morelli@gmail.com; Chesis, Paul

    Congenital anomalies of the inferior vena cava (IVC) are increasingly recognized with CT and venography techniques. Although many patients with IVC anomalies are asymptomatic, recent studies have suggested an association with venous thromboembolism. We report the case of a 62-year-old woman with extensive venous clot involving the infrarenal segment of a duplicated left IVC who underwent pharmacomechanical thrombectomy and tissue plasminogen activator catheter-directed thrombolysis with complete deep venous thrombosis resolution. To our knowledge this is the first reported case in the English literature of the use of a Trellis thrombectomy catheter in the setting of duplicated IVC.

  9. Focal Atrial Tachycardia Arising from the Inferior Vena Cava

    PubMed Central

    Lim, Yeong-Min; Uhm, Jae-Sun

    2017-01-01

    The inferior vena cava (IVC) is a rare site of focal atrial tachycardia (AT). Here, we report a 20-year-old woman who underwent catheter ablation for anti-arrhythmic drug-resistant AT originating from the IVC. She had undergone open-heart surgery for patch closure of an atrial septal defect 17 years previously and permanent pacemaker implantation for sinus node dysfunction 6 years previously. The AT focus was at the anterolateral aspect of the IVC-right atrial junction, and it was successfully ablated under three-dimensional electroanatomical-mapping guidance. We suspect that the mechanism of this tachycardia was associated with previous IVC cannulation for open-heart surgery. PMID:28541006

  10. Inferior Vena Cava Filters: Guidelines, Best Practice, and Expanding Indications

    PubMed Central

    DeYoung, Elliot; Minocha, Jeet

    2016-01-01

    Vena caval interruption, currently accomplished by percutaneous image-guided insertion of an inferior vena cava (IVC) filter, is an important therapeutic option in the management of selected patients with venous thromboembolism. The availability of optional (or retrievable) filters, in particular, has altered the practice patterns for IVC filters, with a shift to these devices and expansion of indications for filter placement. As new devices have become available and clinicians have become more familiar and comfortable with IVC filters, the indications for filter placement have continued to evolve and expand. This article reviews current guidelines and expanding indications for IVC filter placement. PMID:27247472

  11. Liver and Vena Cava En Bloc Resection for an Invasive Leiomyosarcoma Causing Budd-Chiari Syndrome, Under Veno-Venous Bypass and Liver Hypothermic Perfusion : Liver Hypothermic Perfusion and Veno-Venous Bypass for Inferior Vena Cava Leiomyosarcoma.

    PubMed

    Ravaioli, Matteo; Serenari, Matteo; Cescon, Matteo; Savini, Carlo; Cucchetti, Alessandro; Ercolani, Giorgio; Del Gaudio, Massimo; Casati, Alberto; Pinna, Antonio Daniele

    2017-02-01

    Leiomyosarcoma of vascular origin is a rare tumor, occurring mainly in the inferior vena cava (IVC). When involving the hepatic vein confluence, it often causes Budd-Chiari syndrome, and IVC removal with a complex hepatectomy is required (Mingoli in J Am Coll Surg 211:145-146, 2010; Griffin in J Surg Oncol 34:53-60, 1987; Heaney in Ann Surg 163:237-241, 1966; Fortner in Ann Surg 180:644-652, 1974). A 57-year-old male, without previous oncological history, presented with Budd-Chiari syndrome due to a leiomyosarcoma extending to the supra-diaphragmatic IVC and involving the right and middle hepatic veins. The patient did not receive neoadjuvant treatment. A femoral to superior vena cava veno-venous bypass was inserted, and both a median sternotomy and phreno-laparotomy with right subcostal extension were performed. A hemi-portocaval shunt was created between the right portal branch and the IVC, while a catheter was connected to the left portal branch for cold perfusion. Under extracorporeal circulation, the IVC was sectioned after infrahepatic and supra-diaphragmatic cross-clamping. The left liver was flushed with Celsior solution and packed with ice. A right trisectionectomy extended to the caudate lobe with en bloc vena cava removal was performed. The IVC was replaced by a cryopreserved aortic homograft, to which the stump of the left hepatic vein was anastomosed. Bypass duration, warm and cold liver ischemia, and operation time were 280 min, 8 min, 112 min, and 11 h, respectively. Duct-to-duct biliary anastomosis tutored by a T-tube was performed, and the patient was discharged on postoperative day 29, without major complications. After 16 months free of disease, the patient developed bilateral lung metastases. After 4 years the patient is still alive and receiving systemic chemotherapy. Leiomyosarcoma of the IVC involving the hepatic veins can be treated with extended hepatectomy and removal of the IVC through extracorporeal circulation.

  12. Catheter-Directed Thrombolysis of Inferior Vena Cava Thrombosis in a 13-Day-Old Neonate and Review of Literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Jawad U.; Takemoto, Clifford M.; Casella, James F.

    Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.

  13. A Novel Technique for Inferior Vena Cava Filter Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn

    Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

  14. Impact of Physician Education and a Dedicated Inferior Vena Cava Filter Tracking System on Inferior Vena Cava Filter Use and Retrieval Rates Across a Large US Health Care Region.

    PubMed

    Wang, Stephen L; Cha, Hsien-Hwa A; Lin, James R; Francis, Bolanos; Elizabeth, Wakley; Martin, Porras; Rajan, Sudhir

    2016-05-01

    To evaluate the effects of physician familiarity with current evidence and guidelines on inferior vena cava (IVC) filter use and the availability of IVC filter tracking infrastructure on retrieval rates. Fourteen continuing medical education-approved in-hospital grand rounds covering evidence-based review of the literature on IVC filter efficacy, patient-centered outcomes, guidelines for IVC filter indications, and complications were performed across a large United States (US) health care region serving more than 3.5 million members. A computer-based IVC filter tracking system was deployed simultaneously. IVC filter use, rates of attempted retrieval, and fulfillment of guidelines for IVC filter indications were retrospectively evaluated at each facility for 12 months before intervention (n = 427) and for 12 months after intervention (n = 347). After education, IVC filter use decreased 18.7%, with a member enrollment-adjusted decrease of 22.2%, despite an increasing IVC filter use trend for 4 years. Reduction in IVC filter use at each facility strongly correlated with physician attendance at grand rounds (r = -0.69; P = .007). Rates of attempted retrieval increased from 38.9% to 54.0% (P = .0006), with similar rates of successful retrieval (82.3% before education and 85.8% after education on first attempt). Improvement in IVC filter retrieval attempts correlated with physician attendance at grand rounds (r = 0.51; P = .051). IVC filter dwell times at first retrieval attempt were similar (10.2 wk before and 10.8 wk after). Physician education dramatically reduced IVC filter use across a large US health care region, and represents a learning opportunity for physicians who request and place them. Education and a novel tracking system improved rates of retrieval for IVC filter devices. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  15. Sonographic aorta/IVC cross-sectional area index for evaluation of dehydration in children.

    PubMed

    Kwon, Hyuksool; Jung, Jae Yun; Lee, Jin Hee; Kwak, Young Ho; Kim, Do Kyun; Jung, Jin Hee; Chang, Ik Wan; Kim, Kyuseok

    2016-09-01

    Current studies have not found sufficient evidence to encourage the use of ultrasound for assessing dehydration in children. We introduce a new sonographic parameter, the "aorta/inferior vena cava (IVC) cross-sectional area index" (Ao/IVCA) measured just inferior to the xiphoid process, for the effective evaluation of dehydration in children. This is a prospective, observational study. We enrolled children who presented to the pediatric emergency department (PED) between May 2014 and January 2015. We measured the maximum diameter of the aorta from inner wall to inner wall, and the long and short axis diameters of IVC using a convex array transducer. Ao/IVCA was calculated and compared with aorta/IVC maximal diameter index (Ao/IVCD) and the clinical dehydration scale (CDS). A total of 34 children were enrolled. We found a statistically significant correlation between Ao/IVCA and CDS (R(2) = 0.30; P <.001). Ao/IVCD did not correlate significantly with CDS (R(2) = 0.08; P =.11). The ability of Ao/IVCA and Ao/IVCD to predict CDS ≥1 was assessed using the receiver operating characteristic analysis. The area under the receiver operating characteristic curve for Ao/IVCA was larger than that for Ao/IVCD (0.87 vs 0.75, P= .04). The cut-off value of Ao/IVCA that yielded the maximum value of Youden index was 1.81 (sensitivity: 72%, specificity: 89%). Ao/IVCA might be a promising index for the assessment of dehydration. The diagnostic performance of Ao/IVCA for dehydration might be higher than that of the method that uses the maximum diameter of IVC and the aorta. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Are too many inferior vena cava filters used? Controversial evidences in different clinical settings: a narrative review.

    PubMed

    Dalla Vestra, Michele; Grolla, Elisabetta; Bonanni, Luca; Pesavento, Raffaele

    2018-03-01

    The use of inferior vena cava filters to prevent pulmonary embolism is increasing mainly because of indications that appear to be unclearly codified and recommended. The evidence supporting this approach is often heterogeneous, and mainly based on observational studies and consensus opinions, while the insertion of an IVC filter exposes patients to the risk of complications and increases health care costs. Thus, several proposed indications for an IVC filter placement remain controversial. We attempt to review the proof on the efficacy and safety of IVC filters in several "special" clinical settings, and assess the robustness of the available evidence for any specific indication to place an IVC filter.

  17. Case report on the non-operative management of a retrievable inferior vena cava filter perforating the duodenum.

    PubMed

    Fernandez-Moure, Joseph S; Kim, Keemberly; Zubair, M Haseeb; Rosenberg, Wade R

    2017-01-01

    Deep vein thrombosis (DVT) continues to be a significant source of morbidity for surgical patients. Placement of a retrievable inferior vena cava (IVC) filter is used when patients have contraindications to anticoagulation or recurrent pulmonary embolism despite therapeutic anticoagulation. Although retrievable IVC filters are often used, they carry a unique set of risks. A 67-year-old man presents to the Emergency Room (ER) following large volume melena and complaining of syncope. One year prior, the patient had been diagnosed with Glioblastoma multiforme, for which he underwent a craniotomy with near-total resection of the mass. He subsequently developed a deep vein thrombosis and underwent placement of a retrievable inferior vena cava (IVC) filter. Computerized tomography (CT) and esophagogastroduodenoscopy showed duodenal perforation by the retrievable IVC filter. The filter was successfully retrieved through an endovascular approach. Retrievable IVC filter placement is the preferred method of pulmonary embolism prevention in patients with significant risk for bleeding. Duodenal perforation by a retrievable IVC filter is a rare and serious complication. It is usually managed surgically, but can also be managed non-operatively. For patients with significant comorbidities or patients who are poor surgical candidates, non-operative management with close monitoring can serve as an initial approach to the patient with a caval enteric perforation secondary to a retrievable IVC filter. Copyright © 2017. Published by Elsevier Ltd.

  18. Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.

    PubMed

    Chen, Lei; Hsiao, Allen; Langhan, Melissa; Riera, Antonio; Santucci, Karen A

    2010-10-01

    Prospectively identifying children with significant dehydration from gastroenteritis is difficult in acute care settings. Previous work by our group has shown that bedside ultrasound (US) measurement of the inferior vena cava (IVC) and the aorta (Ao) diameter ratio is correlated with intravascular volume. This study was designed to validate the use of this method in the prospective identification of children with dehydration by investigating whether the IVC/Ao ratio correlated with dehydration in children with acute gastroenteritis. Another objective was to investigate the interrater reliability of the IVC/Ao measurements. A prospective observational study was carried out in a pediatric emergency department (PED) between November 2007 and June 2009. Children with acute gastroenteritis were enrolled as subjects. A pair of investigators obtained transverse images of the IVC and Ao using bedside US. The ratio of IVC and Ao diameters (IVC/Ao) was calculated. Subjects were asked to return after resolution of symptoms. The difference between the convalescent weight and ill weight was used to calculate the degree of dehydration. Greater than or equal to 5% difference was judged to be significant. Linear regression was performed with dehydration as the dependent variable and the IVC/Ao as the independent variable. Pearson's correlation coefficient was calculated to assess the degree of agreement between observers. A total of 112 subjects were enrolled. Seventy-one subjects (63%) completed follow-up. Twenty-eight subjects (39%) had significant dehydration. The linear regression model resulted in an R² value of 0.21 (p < 0.001) and a slope (B) of 0.11 (95% confidence interval [CI] = 0.08 to 0.14). An IVC/Ao cutoff of 0.8 produced a sensitivity of 86% and a specificity of 56% for the diagnosis of significant dehydration. Forty-eight paired measurements of IVC/Ao ratios were made. The Pearson correlation coefficient was 0.76.   In this pilot study the ratio of IVC to Ao diameters, as measured by bedside US, was a marginally accurate measurement of acute weight loss in children with dehydration from gastroenteritis. The technique demonstrated good interrater reliability. © 2010 by the Society for Academic Emergency Medicine.

  19. Treatment of Superior Vena Cava (SVC) Syndrome and Inferior Vena Cava (IVC) Thrombosis in a Patient with Colorectal Cancer: Combination of SVC Stenting and IVC Filter Placement to Palliate Symptoms and Pave the Way for Port Implantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sauter, Alexander; Triller, Juergen; Schmidt, Felix

    Thrombosis of the inferior vena cava is a life-threatening complication in cancer patients leading to pulmonary embolism. These patients can also be affected by superior vena cava syndrome causing dyspnea followed by trunk or extremity swelling. We report the case of a 61-year-old female suffering from an extended colorectal tumor who became affected by both of the mentioned complications. Due to thrombus formation within the right vena jugularis interna, thrombosis of the inferior vena cava, and superior vena cava syndrome, a combined interventional procedure via a left jugular access with stenting of the superior vena cava and filter placement intomore » the inferior vena cava was performed As a consequence, relief of the patient's symptoms, prevention of pulmonary embolism, and paving of the way for further venous chemotherapy were achieved.« less

  20. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdel-Aal, Ahmed Kamel, E-mail: akamel@uabmc.edu; Saddekni, Souheil; Hamed, Maysoon Farouk

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of anmore » IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.« less

  1. Techniques of adrenal venous sampling in patients with inferior vena cava or renal vein anomalies.

    PubMed

    Endo, Kenji; Morita, Satoru; Suzaki, Shingo; Yamazaki, Hiroshi; Nishina, Yu; Sakai, Shuji

    2018-06-01

    To review the techniques and technical success rate of adrenal venous sampling (AVS) in patients with inferior vena cava (IVC) or renal vein anomalies. The techniques and success rate of AVS in 15 patients with anomalies [8 with double IVC (dIVC), 3 with left IVC (ltIVC), 2 with retroaortic left renal vein (LRV), and 2 with circumaortic LRV] underwent AVS was retrospectively reviewed. Among 11 patients with IVC anomalies, the success rates for sampling the right and left adrenal veins (RAV and LAV) were 81.8 and 90.9%, respectively. In dIVC, the LAV was selected using the following four methods: approaching through the right IVC from the right femoral vein, flipping the LAV catheter tip in the LRV (n = 4) or the interiliac-communicating vein (n = 1), or through the ltIVC from the right (n = 1) or left (n = 2) femoral vein. Among the four patients with LRV anomalies, the success rate was 100% for each adrenal vein. AVS can be successfully performed in patients with anomalies. The key to technical success is understanding the venous anatomy based on pre-procedural CT images and choosing appropriate methods.

  2. Adult Wilms tumor with inferior vena cava thrombus and distal deep vein thrombosis - a case report and literature review.

    PubMed

    Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel

    2018-02-23

    Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.

  3. Vena Cava Filter Retrieval with Aorto-Iliac Arterial Strut Penetration.

    PubMed

    Holly, Brian P; Gaba, Ron C; Lessne, Mark L; Lewandowski, Robert J; Ryu, Robert K; Desai, Kush R; Sing, Ronald F

    2018-05-03

    To evaluate the safety and technical success of inferior vena cava (IVC) filter retrieval in the setting of aorto-iliac arterial strut penetration. IVC filter registries from six large United States IVC filter retrieval practices were retrospectively reviewed to identify patients who underwent IVC filter retrieval in the setting of filter strut penetration into the adjacent aorta or iliac artery. Patient demographics, implant duration, indication for placement, IVC filter type, retrieval technique and technical success, adverse events, and post procedural clinical outcomes were identified. Arterial penetration was determined based on pre-procedure CT imaging in all cases. The IVC filter retrieval technique used was at the discretion of the operating physician. Seventeen patients from six US centers who underwent retrieval of an IVC filter with at least one strut penetrating either the aorta or iliac artery were identified. Retrieval technical success rate was 100% (17/17), without any major adverse events. Post-retrieval follow-up ranging from 10 days to 2 years (mean 4.6 months) was available in 12/17 (71%) patients; no delayed adverse events were encountered. Findings from this series suggest that chronically indwelling IVC filters with aorto-iliac arterial strut penetration may be safely retrieved.

  4. Two cases of the double inferior venae cavae.

    PubMed

    Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S

    2000-10-01

    Two cases of the double inferior venae cavae (IVC) were found during the student dissection practice in 1997 in Gifu University School of Medicine. On the first case (70-year-old male), the calibers of the right and left IVC were 15 mm and 13 mm, respectively. An anastomosis (4-mm caliber) ran obliquely from the left internal iliac vein to the right IVC. On the second case (86-year-old male), the calibers of the right and left IVC were 15 mm and 10 mm, respectively. We found no anastomosis between the right and left IVC. Each IVC was observed behind the ureter. Both cases belong to Type BC of the classification of McClure and Butler (1925), that is based on the combinations of the right and left IVC, and on their location to the ureters. Both cases also belong to Type II-b-2 of the classification of Takemoto et al. (1978), that is based on the calibers of the right and left IVC and on the running course of the interiliac vein. These are the first and second cases among 808 cadavers in Gifu University School of Medicine and the 93rd and 94th cases in Japan since 1901.

  5. Surgical Resection and Inferior Vena Cava Reconstruction for Treatment of the Malignant Tumor: Technical Success and Outcomes

    PubMed Central

    2014-01-01

    Objective: The purpose of this study was to review patients who underwent inferior vena cava (IVC) resection with concomitant malignant tumor resection and to consider the operative procedures and the outcomes. Materials and Methods: Between 2000 and 2012, 41 patients underwent resection of malignant tumors concomitant with surgical resection of the IVC at our institute. The records of these patients were retrospectively reviewed. Results: Primary tumor resections included nephrectomy, hepatectomy, retroperitoneal tumor extirpation, lymph node dissection, and pancreaticoduodenectomy. The IVC interventions were partial resection in 23 patients and total resection in 18 patients. Four patients underwent IVC replacement. Operation-related complications included pulmonary embolism, acute myocardial infarction, deep vein thrombosis, leg edema and temporary hemodialysis. There were no operative deaths. The mean follow-up period was 24.9 months (range: 2–98 months). The prognosis depended on the type and stage of the tumor. Conclusion: Resection and reconstruction of the IVC can be performed safely if the preoperative evaluations and surgical procedures are performed properly. The IVC resection without reconstruction was permissive if the IVC was completely obstructed preoperatively, but it may also be considered in cases where the IVC is not completely obstructed. PMID:24995055

  6. Etiology and VTE risk factor distribution in patients with inferior vena cava thrombosis.

    PubMed

    Linnemann, Birgit; Schmidt, Henriette; Schindewolf, Marc; Erbe, Matthias; Zgouras, Dimitrios; Grossmann, Ralf; Schambeck, Christian; Lindhoff-Last, Edelgard

    2008-01-01

    Inferior vena cava (IVC) thrombosis is a rare event and data detailing the underlying etiology are scarce. Therefore, we reviewed all available cases of IVC thrombosis consecutively registered in the MAISTHRO (MAin-ISar-THROmbosis) database and described the prevalence of VTE risk factors and other conditions contributing to IVC thrombosis development. 53 patients (35 F, 18 M) with IVC thrombosis aged 12 to 79 years were identified. 40 patients (75.5%) developed thrombosis under the age of 45. Local problems, such as IVC anomalies or external venous compression, contributed to the development of thrombosis in 12 cases (22.6%). Lupus anticoagulants (10.9 vs. 2.3%, p=0.013) and malignoma (17.0 vs. 6.4%, p=0.023) were more prevalent in IVC thrombosis patients compared to 265 age and sex matched controls with isolated lower extremity DVT. No difference was identified with regard to inherited thrombophilia or other known VTE risk factors. Symptomatic pulmonary embolism (PE) occurred in 32.1% of IVC thrombosis patients compared to 15.2% of controls (p=0.005). Local problems such as IVC anomalies and external venous compression, malignancy and the presence of lupus anticoagulants contribute to the risk of IVC thrombosis. The risk of symptomatic pulmonary embolism in the acute setting is high.

  7. A resolved two-way coupled CFD/6-DOF approach for predicting embolus transport and the embolus-trapping efficiency of IVC filters.

    PubMed

    Aycock, Kenneth I; Campbell, Robert L; Manning, Keefe B; Craven, Brent A

    2017-06-01

    Inferior vena cava (IVC) filters are medical devices designed to provide a mechanical barrier to the passage of emboli from the deep veins of the legs to the heart and lungs. Despite decades of development and clinical use, IVC filters still fail to prevent the passage of all hazardous emboli. The objective of this study is to (1) develop a resolved two-way computational model of embolus transport, (2) provide verification and validation evidence for the model, and (3) demonstrate the ability of the model to predict the embolus-trapping efficiency of an IVC filter. Our model couples computational fluid dynamics simulations of blood flow to six-degree-of-freedom simulations of embolus transport and resolves the interactions between rigid, spherical emboli and the blood flow using an immersed boundary method. Following model development and numerical verification and validation of the computational approach against benchmark data from the literature, embolus transport simulations are performed in an idealized IVC geometry. Centered and tilted filter orientations are considered using a nonlinear finite element-based virtual filter placement procedure. A total of 2048 coupled CFD/6-DOF simulations are performed to predict the embolus-trapping statistics of the filter. The simulations predict that the embolus-trapping efficiency of the IVC filter increases with increasing embolus diameter and increasing embolus-to-blood density ratio. Tilted filter placement is found to decrease the embolus-trapping efficiency compared with centered filter placement. Multiple embolus-trapping locations are predicted for the IVC filter, and the trapping locations are predicted to shift upstream and toward the vessel wall with increasing embolus diameter. Simulations of the injection of successive emboli into the IVC are also performed and reveal that the embolus-trapping efficiency decreases with increasing thrombus load in the IVC filter. In future work, the computational tool could be used to investigate IVC filter design improvements, the effect of patient anatomy on embolus transport and IVC filter embolus-trapping efficiency, and, with further development and validation, optimal filter selection and placement on a patient-specific basis.

  8. Late endovascular removal of Günther-Tulip inferior vena cava filter and stent reconstruction of chronic post-thrombotic iliocaval obstruction after 4753 days of filter dwell time: a case report with review of literature.

    PubMed

    Doshi, Mehul Harshad; Narayanan, Govindarajan

    2016-12-01

    Chronic post-thrombotic obstruction of the inferior vena cava (IVC) or iliocaval junction is an uncommon complication of long indwelling IVC filter. When such an obstruction is symptomatic, endovascular treatment options include stent placement with or without filter retrieval. Filter retrieval becomes increasingly difficult with longer dwell times. We present a case of symptomatic post-thrombotic obstruction of the iliocaval junction related to Günther-Tulip IVC filter (Cook Medical Inc, Bloomington, IN) with dwell time of 4753 days, treated successfully with endovascular filter removal and stent reconstruction. Filter retrieval and stent reconstruction may be a treatment option in symptomatic patients with filter-related chronic IVC or iliocaval junction obstruction, even after prolonged dwell time.

  9. Pheochromocytoma with inferior vena cava thrombosis: An unusual association.

    PubMed

    Kota, Sunil K; Kota, Siva K; Jammula, Sruti; Meher, Lalit K; Modi, Kirtikumar D

    2012-04-01

    Pheochromocytomas have been described in association with vascular abnormalities like renal artery stenosis. A 48-year-old man was admitted to our hospital with the complaints of headache, sweating, anxiety, dizziness, nausea, vomiting and hypertension. For last several days, he was having a dull aching abdominal pain. Abdominal computed tomography (CT) revealed the presence of a left adrenal pheochromocytoma. An inferior vena cava (IVC) venogram via the right jugular vein demonstrated occlusion of the IVC inferior to the right atrium. Surgical removal of pheochromocytoma was done, followed by anticoagulant treatment for IVC thrombosis, initially with subcutaneous low molecular weight heparin, and then with oral warfarin, resulting in restoration of patency. To the best of our knowledge, the occurrence of pheochromocytoma in IVC thrombosis has not been reported so far from India. Possible mechanisms of such an involvement are discussed.

  10. CT of inferior vena cava filters: normal presentations and potential complications.

    PubMed

    Georgiou, Nicholas A; Katz, Douglas S; Ganson, George; Eng, Kaitlin; Hon, Man

    2015-12-01

    With massive pulmonary embolism (PE) being the first or second leading cause of unexpected death in adults, protection against PE is critical in appropriately selected patients. The use of inferior vena cava (IVC) filters has increased over the years, paralleling the increased detection of deep venous thrombosis (DVT) and PE by improved and more available imaging techniques. The use of IVC filters has become very common as an alternative and/or as a supplement to anticoagulation, and these filters are often seen on routine abdominal CT, including in the emergency setting; therefore, knowledge of the normal spectrum of findings of IVC filters by the radiologist on CT is critical. Additionally, CT can be used specifically to identify complications related to IVC filters, and CT may alternatively demonstrate IVC filter-related problems which are not specifically anticipated clinically. With multiple available IVC filters on the US market, and even more available outside of the USA, it is important for the emergency and the general radiologist to recognize the different models and various appearances and positioning on CT, as well as their potential complications. These complications may be related to venous access, but also include thrombosis related to the filter, filter migration and penetration, and problems associated with filter deployment. With the increasing number of inferior vena cava filters placed and their duration within patients increasing over time, it is critical for emergency and other radiologists to be aware of these findings on CT.

  11. Inferior vena cava collapsibility detects fluid responsiveness among spontaneously breathing critically-ill patients.

    PubMed

    Corl, Keith A; George, Naomi R; Romanoff, Justin; Levinson, Andrew T; Chheng, Darin B; Merchant, Roland C; Levy, Mitchell M; Napoli, Anthony M

    2017-10-01

    Measurement of inferior vena cava collapsibility (cIVC) by point-of-care ultrasound (POCUS) has been proposed as a viable, non-invasive means of assessing fluid responsiveness. We aimed to determine the ability of cIVC to identify patients who will respond to additional intravenous fluid (IVF) administration among spontaneously breathing critically-ill patients. Prospective observational trial of spontaneously breathing critically-ill patients. cIVC was obtained 3cm caudal from the right atrium and IVC junction using POCUS. Fluid responsiveness was defined as a≥10% increase in cardiac index following a 500ml IVF bolus; measured using bioreactance (NICOM™, Cheetah Medical). cIVC was compared with fluid responsiveness and a cIVC optimal value was identified. Of the 124 participants, 49% were fluid responders. cIVC was able to detect fluid responsiveness: AUC=0.84 [0.76, 0.91]. The optimum cutoff point for cIVC was identified as 25% (LR+ 4.56 [2.72, 7.66], LR- 0.16 [0.08, 0.31]). A cIVC of 25% produced a lower misclassification rate (16.1%) for determining fluid responsiveness than the previous suggested cutoff values of 40% (34.7%). IVC collapsibility, as measured by POCUS, performs well in distinguishing fluid responders from non-responders, and may be used to guide IVF resuscitation among spontaneously breathing critically-ill patients. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature

    PubMed Central

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-01-01

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon. We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. PMID:29866665

  13. Complications of inferior vena cava filters

    PubMed Central

    Grewal, Simer; Chamarthy, Murthy R.

    2016-01-01

    Inferior vena cava (IVC) filter placement is a relatively low risk alternative for prophylaxis against pulmonary embolism in patients with pelvic or lower extremity deep venous thrombosis who are not suitable for anticoagulation. There is an increasing trend in the number of IVC filter implantation procedures performed every year. There are many device types in the market and in the early 2000s, the introduction of retrievable filters brought an additional subset of complications to consider. Modern filter designs have led to decreased morbidity and mortality, however, a thorough understanding of the limitations and complications of IVC filters is necessary to weight the risks and benefits of placing IVC filters. In this review, the complications associated with IVC filters are divided into procedure related, post-procedure, and retrieval complications. Differences amongst the device types and retrievable filters are described, though this is limited by a significant lack of prospective studies. Additionally, the clinical presentation as well as prevention and treatment strategies are outlined with each complication type. PMID:28123983

  14. Indications, retrieval rate, and complications of inferior vena cava filters: Single-center experience in Saudi Arabia.

    PubMed

    Shabib, Abdullah Bin; Alsayed, Fahad; Aldughaythir, Saad; Habeeb, Hanan; Al Tamimi, Sumayyah; Masuadi, Emad; Alzahrani, Mohsen; Alaklabi, Ali; Alotaibi, Azzam; Rajendram, Rajkumar; Almegren, Mosaad

    2018-01-01

    Inferior vena cava (IVC) filter is indicated in patients with acute venous thromboembolism (VTE) in whom therapeutic anticoagulation is contraindicated. While prophylactic insertion of an IVC filter may be considered for patients at high risk of VTE, there are significant differences between clinical guidelines on the role of IVC filters. These discrepancies have arisen predominantly because of the paucity of data on the efficacy and safety of IVC filters. We, therefore, evaluated the indications for filter insertion, the rate of filter retrieval and complications in patients who received IVC filters at King Abdulaziz Medical City (KAMC), Riyadh, Saudi Arabia. A descriptive, retrospective review of electronic- and paper-based medical records was performed. Consecutive sampling was used to study all adult patients who received an IVC filter at KAMC between 2007 and 2016 and met the inclusion criteria. A total of 382 IVC filters were inserted. 113 patients (30%) had an acute VTE and a contraindication to anticoagulation while 53 patients (14%) received an IVC filter in the absence of VTE (i.e., prophylactic). Only 124 (32.5%) IVC filters were eventually retrieved. The most common reason for nonretrieval was the need for permanent filtration (155, 60%). Thrombotic complications developed in 72 (19%) patients; nine patients had fatal pulmonary embolism. The insertion of IVC filters in this cohort was associated with low retrieval rate and relatively high incidence of thrombotic complications. Follow-up of patients is required to detect IVC filter-related complications and to increase retrieval rate.

  15. A case of huge colon carcinoma and right renal angiomyolipoma accompanied by proximal deep venous thrombosis, pulmonary embolism and tumor thrombus in the renal vein.

    PubMed

    Ban, Daisuke; Yamamoto, Seiichiro; Kuno, Hirofumi; Fujimoto, Hiroyuki; Fujita, Shin; Akasu, Takayuki; Moriya, Yoshihiro

    2008-10-01

    A preoperative inferior vena cava (IVC) filter is reported to be effective in surgical cases with proximal deep venous thrombosis (DVT) or in which pulmonary embolism (PE) has already developed, and considered to be at high risk of developing secondary fatal PE during or after surgery. However, guidelines for using an IVC filter have yet to be established. The patient in the present report had two huge tumors, ascending colon cancer and renal angiomyolipoma, which occupied the entire right half of the abdomen, coexisting PE, DVT and tumor thrombus in the right renal vein. Secondary PE is fatal in the perioperative period, therefore, the vena cava filters were preoperatively inserted into the supra- and the infrarenal IVC. We successfully removed the tumors without complications. The patient is alive without tumor recurrence and PE or recurrent DVT 1 year and 6 months after surgery. The coexistence of two huge abdominal tumors as potential causes of PE and DVT is extremely rare, and we could have safely undergone the operation, using two vena cava filters in the supra- and infrarenal IVC.

  16. Comparison of right atrial pressure and central venous pressures measured at various anatomical locations in children.

    PubMed

    Lin, Ming-Chih; Fu, Yun-Ching; Jan, Sheng-Ling; Chen, Ying-Tsung; Chi, Ching-Shiang

    2005-01-01

    To compare the right atrial pressure to the central venous pressures measured at different points in spontaneously breathing children and try to find a formula to estimate right atrial pressure by central venous pressure measurement. Fifty-one children, aged 5 +/- 4.7 years, who underwent right heart catheterization were studied. All patients were sedated and breathed naturally. The mean pressure was the electronic mean of nine heart beats calculated by Philips BC4000 digital angiographic system. Mean pressure of the right atrium was compared to those measured at the high superior vena cava (SVC), low SVC, high inferior vena cava (IVC) (T10-11), middle IVC (L1-2), low IVC (L3-4), and iliac vein (L5-S1). Mean pressures of central veins were significantly higher than that of the right atrium (all p<0.01). Adjusted central venous pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) had a good agreement with the right atrial pressure. Central venous pressures are significantly higher than the right atrial pressure in spontaneously breathing children. Adjusted pressures of SVC-0.5, high IVC-1.5, middle IVC-2, low IVC-2.5, and iliac vein-3 (mmHg) can accurately reflect the right atrial pressure.

  17. CT Appearance of Traumatic Inferior Vena Cava Injury.

    PubMed

    Tsai, Richard; Raptis, Constantine; Schuerer, Douglas J; Mellnick, Vincent M

    2016-07-19

    CT plays a crucial role in the evaluation of stable patients with blunt and penetrating trauma in the emergency department. Among the more severe injuries that may occur in penetrating and blunt trauma are those to the inferior vena cava (IVC). The purpose of this study was to evaluate and differentiate the CT findings associated with penetrating versus blunt trauma to the IVC to aid the radiologist in diagnosing IVC injuries. Cases of blunt and penetrating IVC injury were retrospectively identified using search queries. Criteria for inclusion were preoperative contrast-enhanced CT and surgically confirmed caval injury or direct findings of caval injury on CT with patient death before surgical confirmation could be obtained. Twelve cases of traumatic IVC injury were identified over a 9-year period: six blunt and six penetrating. The most common finding was a retroperitoneal hematoma, seen in 75% of cases. Eighty-three percent of blunt injuries were associated with hepatic lacerations and contrast material extravasation. Thirty-three percent of penetrating IVC injuries were associated with extravasation. Contour abnormalities were seen in 50% of blunt and 17% of penetrating injuries to the IVC. All three cases of IVC injury resulting in mortality occurred in the retrohepatic segment. Injury to the IVC is frequently fatal in patients with penetrating or blunt trauma. The CT appearance of IVC injury is dichotomous between the two causes, with blunt IVC injury more likely to show extravasation, contour abnormality, and associated hepatic laceration. Injury of the retrohepatic IVC portends a poor outcome. With the continued use of CT for evaluation of trauma patients, the radiologist should be familiar with IVC injury and its different CT appearances.

  18. Inferior Vena Cava Filter Placement and Retrieval Rates among Radiologists and Nonradiologists.

    PubMed

    Guez, David; Hansberry, David R; Eschelman, David J; Gonsalves, Carin F; Parker, Laurence; Rao, Vijay M; Levin, David C

    2018-04-01

    To evaluate inferior vena cava (IVC) filter placement and retrieval rates among radiologists, vascular surgeons, cardiologists, other surgeons, and all other health care providers for Medicare fee-for-service beneficiaries in the years 2012-2015. The nationwide Medicare Physician/Supplier Procedure Summary Master Files were used to determine the volume and utilization rate of IVC filter placement, IVC filter repositioning, and IVC filter retrieval, which correspond to procedure codes 37191, 37192, and 37193, respectively. Procedural code 37193 was not available before 2012, so data were reviewed for the years 2012-2015. The total volume of Medicare IVC filter placement decreased from 57,785 in 2012 to 44,378 in 2015, with radiologists responsible for 60% of all filter placements. Volume of IVC filter placement declined across all specialties, including radiologists, who placed 33,744 in 2012 and 27,957 in 2015. In contrast, total retrieval of IVC filters increased from 4,060 removals in 2012 to 6,166 in 2015. Retrieval rate per 100,000 Medicare beneficiaries increased from 11 in 2012 to 16 in 2015. Radiologists removed the bulk of the filters: 64% in both 2012 and 2015. Vascular surgeons, cardiologists, and other surgeons retrieved, respectively, 20%, 10%, and 5% of all IVC filters in 2012 and 22%, 9%, and 5% in 2015. From 2012 to 2015, IVC filter placement steadily decreased across all specialties. Retrieval rate of IVC filters continued to rise over the same period. Radiologists were responsible for the majority of IVC filter placements and retrievals. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  19. Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Qingqiao, E-mail: 1427286069@qq.com; Huang, Qianxin, E-mail: 18705206105@163.com; Shen, Bin, E-mail: 753021357@qq.com

    PurposeThis study was designed to investigate the safety and efficacy of endovascular intervention for the treatment of primary entire-inferior vena cava (IVC) occlusion.MethodsEndovascular interventions were performed in six patients for the treatment of primary entire-IVC occlusion. IVC and hepatic venography were performed via the jugular and femoral veins. Balloon angioplasty was used to revascularize the hepatic vein and IVC and a stent was placed in the IVC to maintain patency. Postoperative color Doppler ultrasonography was performed at 1, 3, 6, and 12 months, and then annually, to monitor the patency of the hepatic vein and IVC.ResultsThe IVC and one or twomore » hepatic veins were successfully revascularized in five patients. Revascularization was successful in the right and left hepatic veins in one patient; however, IVC patency could not be established in this patient. Eleven Z-type, self-expanding stents were placed into the IVCs of five patients (three stents in two patients, two stents in two patients, and one stent in one patient). There were no instances of postoperative bleeding or mortality. Follow-up was conducted for 18–90 months (42.8 ± 26.5 months). None of the five patients suffered restenosis of the IVC or hepatic veins. However, there was one of the six cases of right hepatic vein restenosis at 18 months postprocedure that was revascularized after a second balloon dilatation.ConclusionsEndovascular intervention is safe and efficacious for the treatment of primary entire-IVC occlusion.« less

  20. A case of left inferior vena cava.

    PubMed

    Yano, R; Hayakawa, D; Emura, S; Chen, H; Ozawa, Y; Taguchi, H; Shoumura, S

    2001-12-01

    A case of left inferior vena cava (IVC) was found in a 72-year-old male cadaver during student dissection practice in 1999 at Gifu University School of Medicine. It was formed by junction of the left and right common iliac veins at the lower left corner of the 5th lumbar vertebra. This IVC (15-mm caliber) ascended 82 mm along the left side of the abdominal aorta dorsally to the ureter. Receiving the left renal vein, it became 21 mm in caliber and ran obliquely upward for 43 mm across the abdominal aorta. As soon as it received two right renal veins at the level of the 2nd lumbar vertebra, the IVC (25-mm caliber) turned directly above. The present case belongs to Type C of the classification of McClure and Butler (1925), which is based on the combinations of the left and right IVCs, and on their location relative to the ureters. The present case also belongs to Type 1 of the classification of Yoshida et al. (1981). We consider that left IVC in the present case is mainly caused by disappearance of the right supracardinal vein and persistence of the left one during the embryological development of the IVC.

  1. Left-sided and duplicate inferior vena cava: a case series and review.

    PubMed

    Ang, Wee Choen; Doyle, Terry; Stringer, Mark D

    2013-11-01

    Left-sided and duplicate inferior vena cava (IVC) are two major anatomical variants within the spectrum of IVC malformations, both of which are developmental abnormalities of the supracardinal veins. Four clinical cases are described to highlight the computed tomographic appearances of these vascular malformations and provide novel data on venous dimensions. A systematic review of the recent literature (2000-2011) was conducted focusing on the anatomy, demographics, and associated pathology (congenital and acquired) of isolated left-sided and duplicate IVC. A total of 73 relevant articles were retrieved, consisting of case reports and small case series. The prevalence of left-sided IVC is about 0.1-0.4% and that for duplicate IVC about 0.3-0.4%; both anomalies show a slight male preponderance. In each condition, there are documented variations in the course and tributaries of the IVC. The clinical importance of these anomalies lies in three principal areas: the potential for misdiagnosis on imaging; technical difficulties during retroperitoneal surgery (particularly abdominal aortic aneurysm repair and live donor nephrectomy); and their significance in relation to the etiology and management of venous thromboembolism. Copyright © 2012 Wiley Periodicals, Inc.

  2. Proposal for a new classification of variations in the iliac venous system based on internal iliac veins: a case series and a review of double and left inferior vena cava.

    PubMed

    Hayashi, Shogo; Naito, Munekazu; Hirai, Shuichi; Terayama, Hayato; Miyaki, Takayoshi; Itoh, Masahiro; Fukuzawa, Yoshitaka; Nakano, Takashi

    2013-09-01

    There are many reports on variations in the inferior vena cava (IVC), particularly double IVC (DIVC) and left IVC (LIVC). However, no systematic report has recorded iliac vein (IV) flow patterns in the DIVC and LIVC. In this study, we examined IV flow patterns in both DIVC and LIVC observed during gross anatomy courses conducted for medical students and in previously reported cases. During the gross anatomy courses, three cases of DIVC and one case of LIVC were found in 618 cadavers. The IV flow pattern from these four cases and all other previously reported cases can be classified into one of the following three types according to the vein into which the internal iliac vein drained: the ipsilateral external IV; confluence of the ipsilateral external IV and IVC; and the communicating vein, which connects the IVC and the contralateral IVC or its iliac branch. This classification, which is based on the internal IV course, is considered to be useful because IV variations have the potential to cause clinical problems during related retroperitoneal surgery, venous interventional radiology, and diagnostic procedures for pelvic cancer.

  3. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass.

    PubMed

    Kumar, Santosh; Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-03-16

    A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour.

  4. Perivascular epithelioid cell tumour (PEComa) of the inferior vena cava presenting as an adrenal mass

    PubMed Central

    Lal, Anupam; Acharya, Naveen; Sharma, Varun

    2010-01-01

    Abstract A 54-year-old woman had a mass located in the right suprarenal area. On imaging, this mass appeared to be infiltrating the inferior vena cava (IVC). Exploratory laparotomy was undertaken and excision of the tumour was done with the sleeve of the involved IVC. The mass turned out to be a perivascular epithelioid cell tumour (PEComa) on histopathological examination. This report describes previously reported cases of PEComa in brief and highlights the problems associated with the management of this tumour. PMID:20233679

  5. Retrievable Inferior Vena Cava Filters for Venous Thromboembolism

    PubMed Central

    Win, Lei Lei

    2013-01-01

    Inferior vena cava (IVC) filters are used as an alternative to anticoagulants for prevention of fatal pulmonary embolism (PE) in venous thromboembolic disorders. Retrievable IVC filters have become an increasingly attractive option due to the long-term risks of permanent filter placement. These devices are shown to be technically feasible in insertion and retrieval percutaneously while providing protection from PE. Nevertheless, there are complications and failed retrievals with these retrievable filters. The aim of the paper is to review the retrievable filters and their efficacy, safety, and retrievability. PMID:24967292

  6. Case of a Misplaced IVC Filter: A Lesson to Learn

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Sanjay, E-mail: drssharma@hotmail.com; Mukund, Amar, E-mail: dramarmukund@gmail.co; Agarwal, Sandeep, E-mail: sandeep_aiims@yahoo.co.i

    2010-08-15

    The inferior vena cava (IVC) filter insertion is a well established procedure to prevent significant pulmonary embolism in selected situations. It is generally considered straight forward without significant complications. We report an interesting case of a young postpartum woman in whom an IVC filter was misplaced in the right gonadal vein. This complication is only rarely reported. Presence of prominent right gonadal vein must always be kept in mind during trans-jugular placement of infra renal filter in the IVC in post partum women.

  7. Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience.

    PubMed

    Cohoon, Kevin P; McBride, Joseph; Friese, Jeremy L; McPhail, Ian R

    2015-10-01

    Evaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice. Retrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short-term protection against pulmonary embolism. All patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. During a three-year-period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus. Retrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.

  8. Experimental investigation of the effects of inserting a bovine venous valve in the inferior vena cava of Fontan circulation

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Johnson, Jacob; Kotz, Monica; Tang, Elaine; Khiabani, Reza; Yoganathan, Ajit; Maher, Kevin

    2012-11-01

    The Fontan procedure is a palliative surgery performed on patients with single ventricle (SV) congenital heart defects. The SV is used for systemic circulation and the venous return from the inferior vena cava (IVC) and superior vena cava (SVC) is routed to the pulmonary arteries (PA), resulting in a total cavopulmonary connection (TCPC). Hepatic venous hypertension is commonly manifested in the Fontan circulation, leading to long-term complications including liver congestion and cirrhosis. Respiratory intrathoracic pressure changes affect the venous return from the IVC to the PA. Using a physical model of an idealized TCPC, we examine placement of a unidirectional bovine venous valve within the IVC as a method of alleviating hepatic venous hypertension. A piston pump is used to provide pulsatility in the internal flow through the TCPC, while intrathoracic pressure fluctuations are imposed on the external walls of the model using a pair of linear actuators. When implanted in the extrathoracic position, the hepatic venous pressure is lowered from baseline condition. The effects of changing caval flow distribution and intrathoracic pressure on TCPC hemodynamics will be examined.

  9. Statewide Inferior Vena Cava Filter Placement, Complications, and Retrievals: Epidemiology and Recent Trends.

    PubMed

    Charalel, Resmi A; Durack, Jeremy C; Mao, Jialin; Ross, Joseph S; Meltzer, Andrew J; Sedrakyan, Art

    2018-03-01

    Public awareness of inferior vena cava (IVC) filter-related controversies has been elevated by the Food and Drug Administration (FDA) safety communication in 2010. To examine population level trends in IVC filter utilization, complications, retrieval rates, and subsequent pulmonary embolism (PE) risk. A retrospective cohort study. Patients receiving IVC filters during 2005-2014 in New York State. IVC filter-specific complications, new PE occurrences and IVC filter retrievals were evaluated as time-to-event data using Kaplan-Meier analysis. Estimated cumulative risks were obtained at various timepoints during follow-up. There were 91,873 patients receiving IVC filters between 2005 and 2014 in New York State included in the study. The average patient age was 67 years and 46.6% were male. Age-adjusted rates of IVC filter placement increased from 48 cases/100,000 in 2005 to 52 cases/100,000 in 2009, and decreased afterwards to 36 cases/100,000 in 2014. The estimated risks of having an IVC filter-related complication and filter retrieval within 1 year was 1.5% [95% confidence interval (CI), 1.4%-1.6%] and 3.5% (95% CI, 3.4%-3.6%). One-year retrieval rate was higher post-2010 when compared with pre-2010 years (hazard ratio, 2.70; 95% CI, 2.50-2.91). Among the 58,176 patients who did not have PE events before or at the time of IVC filter placement, the estimated risk of developing subsequent PE at 1 year was 2.0% (95% CI, 1.9%-2.1%). Our findings suggest that FDA communications may be effective in modifying statewide clinical practices. Given the 2% observed PE rate following prophylactic IVC filter placement, large scale pragmatic studies are needed to determine contemporary safety and effectiveness of IVC filters.

  10. Comparison of retrievable stents and permanent stents for Budd-Chiari syndrome due to obstructive inferior vena cava.

    PubMed

    Bi, Yonghua; Chen, Hongmei; Ding, Penxu; Ren, Jianzhuang; Han, Xinwei

    2018-05-30

    To compare long-term outcomes of retrievable stents and permanent stents for BCS due to long-segment obstructive IVC. Between July 2000 and August 2016, 42 patients with BCS due to long-segment obstructive IVC were treated with retrievable stents (RS) and 41 patients were treated with permanent stents (PS). The retrievable stents was removed eventually after thrombus disappeared. Patients were subsequently followed-up by color Doppler sonography or CT scanning. All retrievable stent placements were successfully, and 37 retrievable stents were retrieved 8 to 29 days later. Forty-two stents were implanted in PS Group. One failure retrieval of retrievable stents occurred, and two failures of cannulations were found in PS Group. Two deaths may procedure-related and died from acute pulmonary thromboembolism perioperatively. One patient developed acute cerebral infarction and recovered after treatment. In PS Group, minor complications were found in 3 patients. The length of IVC lesion segment, length and thickness of IVC thrombus decreased significantly, and diameter of retrocaval IVC and diaphragm IVC increased significantly in both groups. During follow up, 3 patients died from liver failure in RS Group and 2 patients died in PS Group. RS Group showed a significantly higher primary patency rate than PS Group. Cumulative 1-, 3-, and 5-year secondary patency rates were 95.2%, 89.6%, 89.6% in RS Group, and 100%, 96.6%, 96.6% in PS Group (p= 0.7109). Retrievable stents is effective for BCS due to long-segment obstructive IVC, with a higher primary patency rate. This article is protected by copyright. All rights reserved.

  11. Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type

    PubMed Central

    Deso, Steven E.; Idakoji, Ibrahim A.; Kuo, William T.

    2016-01-01

    Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90–100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30–50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters. PMID:27247477

  12. A case of double inferior vena cava with renal, ovarian and iliac vein variation.

    PubMed

    Ito, Taro; Ikeda, Yayoi

    2018-01-01

    We encountered a rare case of an anatomic variant of inferior vena cava (IVC) duplication with renal, ovarian and iliac vein variation in an 81-year-old Japanese female cadaver during a student dissection course of anatomy at Aichi Gakuin University School of Dentistry. The two IVCs ran upwards bilaterally to the abdominal aorta. The left IVC joined with the left renal vein (RV) to form a common trunk that crossed anterior to the aorta and ended at the right IVC. We detected a vein [interiliac vein (IiV)] connecting the two IVCs at the level of the aortic bifurcation. The IiV was formed by the union of two tributaries from the left IVC and a tributary from the left internal iliac vein (IIV) and ran obliquely upwards from left to right. Two right ovarian veins, arising separately from the ipsilateral pampiniform plexus, ran vertically in parallel to each other, and each one independently terminated at the right IVC and the right RV. Two right IIVs, connecting each other with small branches, ascended and separately joined the right external iliac vein. The right and left IIVs were connected to each other. These variations cause abnormal drainage, which could lead to clinical symptoms associated with the dysfunction of the vascular and urogenital systems. Here we describe the detailed anatomical features of the area and discuss the related anatomical and developmental aspects.

  13. Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach

    PubMed Central

    Inagaki, Elica; Farber, Alik; Eslami, Mohammad H.; Siracuse, Jeffrey J.; Rybin, Denis V.; Sarosiek, Shayna; Sloan, J. Mark; Kalish, Jeffrey

    2017-01-01

    Objective The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. Methods All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. Results In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). Conclusions The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. PMID:27318045

  14. Embolization of Inferior Vena Cava Filter Tyne and Right Ventricular Perforation: A Cardiac Missile.

    PubMed

    Ollila, Thomas; Naeem, Syed; Poppas, Athena; McKendall, George; Ehsan, Afshin

    2016-12-01

    Inferior vena cava (IVC) filter is a medical device placed in patients with proven pulmonary embolism or those with risk of embolization. Although many IVC filters are designed for removal after patient recovery, in many instances they are never retrieved. We present a case of a 22-year-old woman who underwent placement of an IVC filter as a prophylactic measure following a C-6 spinal injury that rendered her a quadriplegic. A tyne from the filter later fractured and embolized to the right ventricle, leading to perforation and subsequent large symptomatic pericardial effusion. The tyne was retrieved through a subxiphoid pericardial window, and the patient had an uneventful recovery. She later underwent retrieval of the entire filter. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Management of acute lower extremity deep venous thrombosis in a patient with duplicated inferior vena cava and contraindication to anticoagulation: case and review of the literature.

    PubMed

    Patel, Shrinil; Cheema, Anmol; Karawadia, Tejas; Carson, Michael

    2018-06-04

    Duplication of the inferior vena cava (DIVC) is an uncommon embryological anatomic phenomenon.We report a 63-year-old woman with extensive right leg deep vein thrombosis who required an IVC filter due to contraindications for anticoagulation, but was found to have DIVC which required the placement of two IVC filters with good result. This report will review and summarise past reports of DIVC management to provide a guide for future clinicians, and review the embryological development, diagnosis and IVC filter placement options as they are based on the type of anatomic malformation encountered. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Creation of an iOS and Android Mobile Application for Inferior Vena Cava (IVC) Filters: A Powerful Tool to Optimize Care of Patients with IVC Filters

    PubMed Central

    Deso, Steven E.; Idakoji, Ibrahim A.; Muelly, Michael C.; Kuo, William T.

    2016-01-01

    Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board–approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters. PMID:27247483

  17. Creation of an iOS and Android Mobile Application for Inferior Vena Cava (IVC) Filters: A Powerful Tool to Optimize Care of Patients with IVC Filters.

    PubMed

    Deso, Steven E; Idakoji, Ibrahim A; Muelly, Michael C; Kuo, William T

    2016-06-01

    Owing to a myriad of inferior vena cava (IVC) filter types and their potential complications, rapid and correct identification may be challenging when encountered on routine imaging. The authors aimed to develop an interactive mobile application that allows recognition of all IVC filters and related complications, to optimize the care of patients with indwelling IVC filters. The FDA Premarket Notification Database was queried from 1980 to 2014 to identify all IVC filter types in the United States. An electronic search was then performed on MEDLINE and the FDA MAUDE database to identify all reported complications associated with each device. High-resolution photos were taken of each filter type and corresponding computed tomographic and fluoroscopic images were obtained from an institutional review board-approved IVC filter registry. A wireframe and storyboard were created, and software was developed using HTML5/CSS compliant code. The software was deployed using PhoneGap (Adobe, San Jose, CA), and the prototype was tested and refined. Twenty-three IVC filter types were identified for inclusion. Safety data from FDA MAUDE and 72 relevant peer-reviewed studies were acquired, and complication rates for each filter type were highlighted in the application. Digital photos, fluoroscopic images, and CT DICOM files were seamlessly incorporated. All data were succinctly organized electronically, and the software was successfully deployed into Android (Google, Mountain View, CA) and iOS (Apple, Cupertino, CA) platforms. A powerful electronic mobile application was successfully created to allow rapid identification of all IVC filter types and related complications. This application may be used to optimize the care of patients with IVC filters.

  18. Establishment of an inferior vena cava filter database and interventional radiology led follow-up - retrieval rates and patients lost to follow-up.

    PubMed

    Klinken, Sven; Humphries, Charlotte; Ferguson, John

    2017-10-01

    To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = < 0.001). There was a non-significant reduction in IVC filter dwell time in the post-database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.

  19. Indications, applications, and outcomes of inferior vena cava filters for venous thromboembolism in Japanese patients.

    PubMed

    Yamashita, Yugo; Unoki, Takashi; Takagi, Daisuke; Hamatani, Yasuhiro; Ishii, Mitsuru; Iguchi, Moritake; Ogawa, Hisashi; Masunaga, Nobutoyo; Wada, Hiromichi; Hasegawa, Koji; Abe, Mitsuru; Akao, Masaharu

    2016-07-01

    A recent multicenter registry study of venous thromboembolism (VTE) patients in Japan demonstrated a high prevalence of inferior vena cava (IVC) filter placement. However, data regarding indications, applications, and outcomes of IVC filters in Japanese patients are quite limited. This study was an observational, single-center, retrospective cohort study of all consecutive patients with acute VTE treated between March 2006 and February 2014. Data extracted included patient demographics, indications, applications, and complications of IVC filters, as well as VTE recurrence and death. A total of 257 consecutive patients were analyzed. Seventy-eight patients (30 %) received IVC filters. The proportions of IVC filter placement were 26 % for deep-vein thrombosis (DVT) alone, 10 % for pulmonary embolism (PE) alone, and 46 % for both DVT and PE. There was no significant difference in patient demographics between the IVC filter group and no-IVC filter group. Stated indications for filter placement were 24 cases (30 %) of DVT in intrapelvic veins, 16 cases (20 %) of DVT in proximal veins, and 11 cases (14 %) of contraindication to anticoagulant therapy. In the IVC filter group, cases of class I indication (guidelines: JCS 75:1258-1281, 2009) numbered only 6 (8 %). Many of the retrievable IVC filters were not removed and placed permanently and the retrieval rate was 42 %. We found complications of IVC filters in 8 cases (10 %). IVC filter placement was significantly associated with a better survival rate and a higher incidence of DVT recurrence during a mean observation period of 541 days. Our research suggests the frequent use of IVC filters for VTE treatment, combined with a low retrieval rate. Most of the stated indications of IVC filter placement for VTE in Japanese patients were cases of DVT in intrapelvic veins or proximal veins, not cases of contraindication to anticoagulant therapy.

  20. Practice patterns of retrievable inferior vena cava filters and predictors of filter retrieval in patients with pulmonary embolism.

    PubMed

    Kang, Jieun; Ko, Heung-Kyu; Shin, Ji Hoon; Ko, Gi-Young; Jo, Kyung-Wook; Huh, Jin Won; Oh, Yeon-Mok; Lee, Sang-Do; Lee, Jae Seung

    2017-12-01

    Retrievable inferior vena cava (IVC) filters are increasingly used in patients with venous thromboembolism (VTE) who have contraindications to anticoagulant therapy. However, previous studies have shown that many retrievable filters are left permanently in patients. This study aimed to identify the common indications for IVC filter insertion, the filter retrieval rate, and the predictive factors for filter retrieval attempts. To this end, a retrospective cohort study was performed at a tertiary care center in South Korea between January 2010 and May 2016. Electronic medical charts were reviewed for patients with pulmonary embolism (PE) who underwent IVC filter insertion. A total of 439 cases were reviewed. The most common indication for filter insertion was a preoperative/procedural aim, followed by extensive iliofemoral deep vein thrombosis (DVT). Retrieval of the IVC filter was attempted in 44.9% of patients. The retrieval success rate was 93.9%. History of cerebral hemorrhage, malignancy, and admission to a nonsurgical department were the significant predictive factors of a lower retrieval attempt rate in multivariate analysis. With the increased use of IVC filters, more issues should be addressed before placing a filter and physicians should attempt to improve the filter retrieval rate.

  1. "Passing loop" technique: a new modification of the piggyback technique tailored to voluminous liver grafts--case report.

    PubMed

    Eldeen, F Z; Lee, C-F; Lee, C-S; Chan, K-M; Lee, W-C

    2013-03-01

    The modified piggyback technique with side-to-side cavocavostomy decreases the risk of outflow obstruction compared with the standard piggyback method. However, this modification is not ideal for recipients who receive a graft that is voluminous or bears an enlarged caudate lobe. We modified the inferior vena cava (IVC) preservation technique against deleterious complications of compression by using a passing loop. A 49-year-old woman, who underwent orthotopic liver transplantation for hepatic failure, was allocated a large-size liver. In anticipation of serious caval compression due to the voluminous grafts, we kept the suprahepatic or infrahepatic donor caval cuffs open for an anastomosis. The first anastomosis was performed between suprahepatic donor IVC cuff and recipient middle-left hepatic vein common channel; the second anastomosis was a terminolateral cavocavostomy between infrahepatic donor IVC cuff and the anterior wall of the recipient's IVC. When the liver circulation was restored, the donor retrohepatic vena cava served as a passing loop for both hepatic venous outflow and infra-diaphragmatic venous return to bypass possible IVC compression. Our technique may solve a dilemna for patients receiving voluminous liver grafts. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Oncological outcomes after cytoreductive nephrectomy for patients with metastatic renal cell carcinoma with inferior vena caval tumor thrombus.

    PubMed

    Miyake, Hideaki; Sugiyama, Takayuki; Aki, Ryota; Matsushita, Yuto; Tamura, Keita; Motoyama, Daisuke; Ito, Toshiki; Otsuka, Atsushi

    2018-06-01

    To evaluate the oncological outcomes of patients with metastatic renal cell carcinoma (mRCC) involving the inferior vena cava (IVC) who received cytoreductive nephrectomy. This study included 75 consecutive metastatis renal cell carcinoma (mRCC) patients with inferior vena cava (IVC) tumor thrombus undergoing cytoreductive nephrectomy and tumor thrombectomy followed by systemic therapy. Of the 75 patients, 11, 33, 24 and 7 had level I, II, III and IV IVC thrombus, respectively. Following surgical treatment, 25 (group A), 27 (group B) and 23 (group C) received cytokine therapy alone, molecular-targeted therapy alone and both therapies, respectively, as management for metastatic diseases. The median overall survival (OS) of the 75 patients was 16.2 months. No significant differences in OS were noted according to the level of the IVC tumor thrombus. There were no significant differences in OS among groups A, B and C; however, OS in groups B and C was significantly superior to that in group A. Furthermore, multivariate analysis of several parameters identified the following independent predictors of poor OS-elevated C-reactive protein, liver metastasis and postoperative treatment with cytokine therapy alone. The prognosis of mRCC patients with IVC thrombus undergoing cytoreductive nephrectomy may be significantly affected by the type of postoperative systemic therapy rather than the level of the IVC tumor thrombus. Accordingly, cytoreductive nephrectomy should be considered as a major therapeutic option for patients with mRCC involving the IVC, particularly in the era of targeted therapy.

  3. Validation of a computerized technique for automatically tracking and measuring the inferior vena cava in ultrasound imagery.

    PubMed

    Bellows, Spencer; Smith, Jordan; Mcguire, Peter; Smith, Andrew

    2014-01-01

    Accurate resuscitation of the critically-ill patient using intravenous fluids and blood products is a challenging, time sensitive task. Ultrasound of the inferior vena cava (IVC) is a non-invasive technique currently used to guide fluid administration, though multiple factors such as variable image quality, time, and operator skill challenge mainstream acceptance. This study represents a first attempt to develop and validate an algorithm capable of automatically tracking and measuring the IVC compared to human operators across a diverse range of image quality. Minimal tracking failures and high levels of agreement between manual and algorithm measurements were demonstrated on good quality videos. Addressing problems such as gaps in the vessel wall and intra-lumen speckle should result in improved performance in average and poor quality videos. Semi-automated measurement of the IVC for the purposes of non-invasive estimation of circulating blood volume poses challenges however is feasible.

  4. CT-guided percutaneous fine-needle aspiration biopsy of the inferior vena cava wall: a posterior coaxial approach.

    PubMed

    Kos, Sebastian; Bilecen, Deniz; Baumhoer, Daniel; Guillaume, Nicolas; Jacob, Augustinus L

    2010-02-01

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of the patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.

  5. CT-Guided Percutaneous Fine-Needle Aspiration Biopsy of the Inferior Vena Cava Wall: A Posterior Coaxial Approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.de; Bilecen, Deniz; Baumhoer, Daniel

    A 72-year-old man was referred to our department with an incidentally diagnosed bronchogenic carcinoma of the right upper lobe. Positron emission tomography (PET) combined with computed tomography (PET-CT) revealed an unexpected hot spot in the ventral wall of the infrarenal segment of the inferior vena cava (IVC). Diagnostic biopsy of this lesion was performed under CT guidance with semiautomated 20G fine-needle aspiration (FNA) through a 19G coaxial needle. Cytology revealed few carcinoma cells, which led to the remarkable diagnosis of a distant metastasis to the IVC wall. Both the immediate postinterventional CT control and the further surveillance period of themore » patient were unremarkable; in particular, no signs of bleeding complications were detected. We conclude that coaxial FNA of an IVC wall lesion is technically feasible and may even help diagnose distant metastasis.« less

  6. Perforation of the IVC: rule rather than exception after longer indwelling times for the Günther Tulip and Celect retrievable filters.

    PubMed

    Durack, Jeremy C; Westphalen, Antonio C; Kekulawela, Stephanie; Bhanu, Shiv B; Avrin, David E; Gordon, Roy L; Kerlan, Robert K

    2012-04-01

    This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Günther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Günther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Günther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissue injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Longer indwelling times usually result in vena caval perforation by retrievable Günther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.

  7. Perforation of the IVC: Rule Rather Than Exception After Longer Indwelling Times for the Guenther Tulip and Celect Retrievable Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durack, Jeremy C., E-mail: jeremy.durack@ucsf.edu; Westphalen, Antonio C.; Kekulawela, Stephanie

    Purpose: This study was designed to assess the incidence, magnitude, and impact upon retrievability of vena caval perforation by Guenther Tulip and Celect conical inferior vena cava (IVC) filters on computed tomographic (CT) imaging. Methods: Guenther Tulip and Celect IVC filters placed between July 2007 and May 2009 were identified from medical records. Of 272 IVC filters placed, 50 (23 Guenther Tulip, 46%; 27 Celect, 54%) were retrospectively assessed on follow-up abdominal CT scans performed for reasons unrelated to the filter. Computed tomography scans were examined for evidence of filter perforation through the vena caval wall, tilt, or pericaval tissuemore » injury. Procedure records were reviewed to determine whether IVC filter retrieval was attempted and successful. Results: Perforation of at least one filter component through the IVC was observed in 43 of 50 (86%) filters on CT scans obtained between 1 and 880 days after filter placement. All filters imaged after 71 days showed some degree of vena caval perforation, often as a progressive process. Filter tilt was seen in 20 of 50 (40%) filters, and all tilted filters also demonstrated vena caval perforation. Transjugular removal was attempted in 12 of 50 (24%) filters and was successful in 11 of 12 (92%). Conclusions: Longer indwelling times usually result in vena caval perforation by retrievable Guenther Tulip and Celect IVC filters. Although infrequently reported in the literature, clinical sequelae from IVC filter components breaching the vena cava can be significant. We advocate filter retrieval as early as clinically indicated and increased attention to the appearance of IVC filters on all follow-up imaging studies.« less

  8. Lymphatic pump treatment increases thoracic duct lymph flow in conscious dogs with edema due to constriction of the inferior vena cava.

    PubMed

    Prajapati, Parna; Shah, Pankhil; King, Hollis H; Williams, Arthur G; Desai, Pratikkumar; Downey, H Fred

    2010-09-01

    Osteopathic lymphatic pump treatments (LPT) are used to treat edema, but their direct effects on lymph flow have not been studied. In the current study, we examined the effects of LPT on lymph flow in the thoracic duct of instrumented conscious dogs in the presence of edema produced by constriction of the inferior vena cava (IVC). Six dogs were surgically instrumented with an ultrasonic flow transducer on the thoracic lymph duct and catheters in the descending thoracic aorta and in IVC. After postoperative recovery, lymph flow and hemodynamic variables were measured 1) pre-LPT, 2) during 4 min LPT, 3) post-LPT, in the absence and presence of edema produced by IVC constriction. This constriction increased abdominal girth from 60 +/-2.6 to 75 +/- 2.9 cm. Before IVC constriction, LPT increased lymph flow (P < 0.05) from 1.9 +/- 0.2 ml/min to a maximum of 4.7 +/-1.2 ml/min, whereas after IVC constriction, LPT increased lymph flow (P < 0.05) from 7.9 +/-2.2 to a maximum of 11.7 +/-2.2 ml/min. The incremental lymph flow mobilized by 4 min of LPT (ie, the flow that exceeded 4 min of baseline flow), was 10.6 ml after IVC constriction. This incremental flow was not significantly greater than that measured before IVC constriction. Edema caused by IVC constriction markedly increased lymph flow in the thoracic duct. LPT increased thoracic duct lymph flow before and after IVC constriction. The lymph flow mobilized by 4 min of LPT in presence of edema was not significantly greater than that mobilized prior to edema.

  9. Disintegration of the 'waterfall phenomenon' in the inferior vena cava due to right heart failure.

    PubMed

    Kira, S; Dambara, T; Mieno, T; Tamaki, S; Natori, H

    1996-03-01

    The concept of the waterfall phenomenon in Zone 2 in the pulmonary vasculature is well known from West's lung model. It is believed that the flow through this zone is determined by the pressure difference between the pulmonary artery and alveoli, and the left atrial pressure is not transmissible to the alveolar capillaries. However, it is impossible to see whether alveolar capillaries are really displaying the waterfall phenomenon or not. In this review, the interrelation between the flow and geometry of the alveolar capillaries in the waterfall phenomenon is analyzed based on physiological studies using a model system and isolated lung lobe experiments. Further, extending the concept to the analysis of ventilatory changes of the inferior vena cava (IVC) configuration, it is ascertained that the waterfall phenomenon normally occurs in the IVC during inspiration just before it enters the thorax and the waterfall phenomenon in the IVC disintegrates with elevation of the central venous pressure. Because these configurations of the IVC in normal and abnormal conditions are visible with ultrasonography, the technique is very useful as a noninvasive approach to diagnose right heart failure.

  10. Thrombus just beneath a retrievable inferior vena cava filter in a pregnant woman with deep vein thrombosis: its removal requiring catheter thrombus fragmentation with fibrinolysis.

    PubMed

    Horie, Kenji; Suzuki, Hirotada; Ohkuchi, Akihide; Matsubara, Shigeki; Ikemoto, Tomokazu; Suzuki, Mitsuaki

    2014-02-01

    Recently, transient inferior vena cava (IVC) filters have been employed to protect against pulmonary embolism (PE) in pregnant women with deep vein thrombosis. A 34-year-old primiparous Japanese woman with a history of myomectomy was diagnosed with deep vein thrombosis by ultrasound at 27 weeks of gestation. Unfractionated heparin was administered, which soon ameliorated swelling in the right thigh. A transient IVC filter was implanted just before cesarean section. An enhanced computed tomography scan 2 days after cesarean section revealed a wide thrombus just distal to the filter. We performed catheter thrombus fragmentation with fibrinolysis just before the removal of the IVC filter, resulting in re-canalization of blood flow. No significant PE occurred. Although a transient IVC filter may work well for the prophylaxis of PE during labor and delivery, catheter fragmentation with fibrinolysis may become necessary at removal of the filter. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.

  11. Three-Dimensional Rotational Angiography of the Inferior Vena Cava as an Adjunct to Inferior Vena Cava Filter Retrieval

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bozlar, Ugur; Edmunds, J. Stewart; Turba, Ulku C.

    The objective of this study was to explore the role of three-dimensional (3-D) rotational angiography (RA) of the inferior vena cava (IVC; 3-D CV) before filter retrieval and its impact on treatment planning compared with standard anteroposterior cavography (sCV). Thirty patients underwent sCV and 3-D CV before IVC filter retrieval. Parameters assessed were: projection of filter arms or legs beyond the caval lumen, thrombus burden within the filter and IVC, and orientation of the filter within IVC. Skin and effective radiation doses were calculated. Statistical analysis was performed using paired Student t test and nonparametric McNemar's test. Standard anteroposterior cavographymore » detected 49 filter arms or legs projecting beyond the caval lumen in 25 patients. Three-dimensional CV demonstrated 89 filter arms or legs projecting beyond the caval lumen in 28 patients. Twenty-two patients had additional filter arms or legs projecting beyond the caval lumen detected on 3-D CV that were not detected on sCV (p < 0.001). Filter apex tilt detection differed significantly (p < 0.001) between sCV and 3-D CV, with 3-D CV being more accurate. The filter apex abutted the IVC wall in 10 patients (33%) on 3-D CV, but this was diagnosed in only 3 patients (10%) with sCV. Thrombus was detected in 8 patients (27%), 1 thrombus of which was seen only on 3-D CV, and treatment was changed in this patient because of thrombus size. Mean effective radiation doses for 3-D CV were approximately two times higher than for sCV (1.68 vs. 0.86 mSv), whereas skin doses were three times lower (12.87 vs. 35.86 mGy). Compared with sCV, performing 3-D CV before optional IVC filter retrieval has the potential to improve assessment of filter arms or legs projecting beyond the caval lumen, filter orientation, and thrombus burden.« less

  12. Improving the retrieval rate of inferior vena cava filters with a multidisciplinary team approach.

    PubMed

    Inagaki, Elica; Farber, Alik; Eslami, Mohammad H; Siracuse, Jeffrey J; Rybin, Denis V; Sarosiek, Shayna; Sloan, J Mark; Kalish, Jeffrey

    2016-07-01

    The option to retrieve inferior vena cava (IVC) filters has resulted in an increase in the utilization of these devices as stopgap measures in patients with relative contraindications to anticoagulation. These retrievable IVC filters, however, are often not retrieved and become permanent. Recent data from our institution confirmed a historically low retrieval rate. Therefore, we hypothesized that the implementation of a new IVC filter retrieval protocol would increase the retrieval rate of appropriate IVC filters at our institution. All consecutive patients who underwent an IVC filter placement at our institution between September 2003 and July 2012 were retrospectively reviewed. In August 2012, a multidisciplinary task force was established, and a new IVC filter retrieval protocol was implemented. Prospective data were collected using a centralized interdepartmental IVC filter registry for all consecutive patients who underwent an IVC filter placement between August 2012 and September 2014. Patients were chronologically categorized into preimplementation (PRE) and postimplementation (POST) groups. Comparisons of outcome measures, including the retrieval rate of IVC filters along with rates of retrieval attempt and technical failure, were made between the two groups. In the PRE and POST groups, a total of 720 and 74 retrievable IVC filters were implanted, respectively. In the POST group, 40 of 74 filters (54%) were successfully retrieved compared with 82 of 720 filters (11%) in the PRE group (P < .001). Furthermore, a greater number of IVC filter retrievals were attempted in the POST group than in the PRE group (66% vs 14%; P < .001). No significant difference was observed between the PRE and POST groups for technical failure (17% vs 18%; P = .9). The retrieval rate of retrievable IVC filters at our institution was significantly increased with the implementation of a new IVC filter retrieval protocol with a multidisciplinary team approach. This improved retrieval rate is possible with minimal dedication of resources and can potentially lead to a decrease in IVC filter-related complications in the future. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  13. Computational Modeling of Blood Flow in the TrapEase Inferior Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Henshaw, W D; Wang, S L

    To evaluate the flow hemodynamics of the TrapEase vena cava filter using three dimensional computational fluid dynamics, including simulated thrombi of multiple shapes, sizes, and trapping positions. The study was performed to identify potential areas of recirculation and stagnation and areas in which trapped thrombi may influence intrafilter thrombosis. Computer models of the TrapEase filter, thrombi (volumes ranging from 0.25mL to 2mL, 3 different shapes), and a 23mm diameter cava were constructed. The hemodynamics of steady-state flow at Reynolds number 600 was examined for the unoccluded and partially occluded filter. Axial velocity contours and wall shear stresses were computed. Flowmore » in the unoccluded TrapEase filter experienced minimal disruption, except near the superior and inferior tips where low velocity flow was observed. For spherical thrombi in the superior trapping position, stagnant and recirculating flow was observed downstream of the thrombus; the volume of stagnant flow and the peak wall shear stress increased monotonically with thrombus volume. For inferiorly trapped spherical thrombi, marked disruption to the flow was observed along the cava wall ipsilateral to the thrombus and in the interior of the filter. Spherically shaped thrombus produced a lower peak wall shear stress than conically shaped thrombus and a larger peak stress than ellipsoidal thrombus. We have designed and constructed a computer model of the flow hemodynamics of the TrapEase IVC filter with varying shapes, sizes, and positions of thrombi. The computer model offers several advantages over in vitro techniques including: improved resolution, ease of evaluating different thrombus sizes and shapes, and easy adaptation for new filter designs and flow parameters. Results from the model also support a previously reported finding from photochromic experiments that suggest the inferior trapping position of the TrapEase IVC filter leads to an intra-filter region of recirculating/stagnant flow with very low shear stress that may be thrombogenic.« less

  14. Effective control of massive venous bleeding by "multioverlapping therapy" using polysaccharide nanosheets in a rabbit inferior vena cava injury model.

    PubMed

    Hagisawa, Kohsuke; Saito, Akihiro; Kinoshita, Manabu; Fujie, Toshinori; Otani, Naoki; Shono, Satoshi; Park, Young-Kwang; Takeoka, Shinji

    2013-07-01

    To investigate the efficacy of multioverlapping therapy using a polysaccharide nanosheet having 75-nm thickness for sealing and stopping massive venous hemorrhage. The hydrostatic durability of the polysaccharide nanosheet was evaluated in vitro when secured to an incised silicon tube. For in vivo studies, the inferior vena cava (IVC) of rabbits was cut longitudinally, and multiple polysaccharide nanosheets were overlapped onto the injured IVC. The mechanical hydrostatic durability of the nanosheets was gradually augmented by an increasing number of multilayered nanosheets in vitro. This durability was saturated at 80 ± 6 mm Hg by four layers of nanosheets, which was robust enough to seal injured vessel walls of the large IVC. Multioverlapping therapy using nanosheets effectively sealed and stopped bleeding from the injured IVC in vivo. One month later, no inflammatory tissue response was observed around the nanosheet attachment sites of the IVC, while conventional suturing repair in control rabbits showed a severe inflammatory response around the sutured area. The multioverlapping therapy using the polysaccharide nanosheets will effectively stop massive venous bleeding without adverse effects in the immediate or chronic postoperative setting. Copyright © 2013 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Congenital Vitelline Band Causing Intestinal Obstruction in an Adult with a Double Inferior Vena Cava

    PubMed Central

    Pussepitiya, Kumari; Samarasinghe, Bandula; Wickramasinghe, Nuwan

    2016-01-01

    Introduction. Vitelline artery remnants are rare causes of intra-abdominal bands leading to bowel obstruction. These bands may be associated with Meckel's diverticulum. Double inferior vena cava (IVC) is a rare presentation and is usually identified incidentally. Case Presentation. A sixty-year-old male presented with progressive vomiting for five days and he was clinically diagnosed with intestinal obstruction. Plain X-ray abdomen showed evidence of small bowel obstruction. CT scan of the abdomen revealed dilated small bowel loops with a small outpouching in the distal ileum with a band like structure attached to it. In the CT, left sided patent IVC draining into the left renal vein was identified. Left external iliac vein was in continuity with the left IVC. Left internal iliac vein was draining into the right IVC. Exploratory laparotomy revealed a Meckel's diverticulum with a band identified as the vitelline remnant attached to its apex and inserting at the anterior abdominal wall near the umbilicus. Discussion. Meckel's diverticulum with vitelline bands, although rare, should be borne in mind in adult patients with intestinal obstruction. Identification of this anomaly can be difficult in imaging studies. Presence of double IVC should be mentioned in the imaging findings to prevent possible catastrophic complications during surgery. PMID:27843667

  16. Congenital abnormalities of the inferior vena cava presenting clinically in adolescent males.

    PubMed

    Halparin, Jessica; Monagle, Paul; Newall, Fiona

    2015-04-01

    Congenital anatomic abnormality of the inferior vena cava (IVC) is an important risk factor for the development of spontaneous proximal lower extremity deep vein thrombosis (DVT) in young adults. The incidence of DVT associated with congenital IVC anomalies in paediatric populations has not been described, and the implications of IVC anomalies for treatment and outcomes of DVT are unknown. This study reports a series of five adolescent males with spontaneous lower extremity DVTs and underlying congenital IVC abnormalities. Cases were identified by searching the institutional database of patients treated with anticoagulation for venous thromboembolism at a tertiary children's hospital. The demographics, clinical presentations, imaging findings, treatment courses, and outcomes are described. All cases occurred in males, and accounted for approximately twenty percent of adolescent males presenting with DVT. IVC abnormality is likely an under-recognized risk factor for DVT in this age group, and detailed vascular imaging should be pursued in adolescents with spontaneous proximal lower extremity DVT when initial ultrasonography does not delineate the proximal clot extent. Management requires individual risk-benefit assessment in the context of providing developmentally appropriate care. Further research is required to establish long-term outcomes and determine optimal treatment strategies. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Renal cell carcinoma with inferior vena cava thrombus extending to the right atrium diagnosed during pregnancy.

    PubMed

    Ghanney, Efe C; Cavallo, Jaime A; Levin, Matthew A; Reddy, Ramachandra; Bander, Jeffrey; Mella, Maria; Stone, Joanne; Schwartz, Myron; Haines, Kenneth; Gidwani, Umesh; Mehrazin, Reza

    2017-12-01

    Only one case of renal cell carcinoma (RCC) with inferior vena cava (IVC) tumor thrombus diagnosed and treated during pregnancy has been reported in the literature. In that report, the tumor thrombus extended to the infrahepatic IVC (level II tumor thrombus). In the present case, a 37-year-old woman with lupus anticoagulant antibodies was diagnosed with RCC and IVC tumor thrombus extending to the right atrium (level IV tumor thrombus) at 24 weeks of pregnancy. The fetus was safely delivered by cesarean section at 30 weeks of gestation. At 4 days later, an open right radical nephrectomy and IVC and right atrial thrombectomy were performed on cardiopulmonary bypass (CPB) once the patient's hemodynamic status had been optimized. Fetal and maternal concerns included the risk of a thromboembolic event (due to increased hypercoagulability from pregnancy, active malignancy, and lupus anticoagulant), intraoperative hemorrhage risk (due to extensive venous collaterals and anticoagulation), and fetal morbidity and mortality (due to fetal lung immaturity). Standardized guidelines for treatment of RCC with or without IVC tumor thrombus during pregnancy are unavailable due to the infrequency of such cases. Treatment decisions are therefore individualized and this case report may inform the management of future patients diagnosed with RCC with level IV tumor thrombus during pregnancy.

  18. Congenital portosystemic venous connections and other abdominal venous abnormalities in patients with polysplenia and functionally univentricular heart disease: a case series and literature review.

    PubMed

    McElhinney, Doff B; Marx, Gerald R; Newburger, Jane W

    2011-01-01

    Published case reports suggest that congenital portosystemic venous connections (PSVC) and other abdominal venous anomalies may be relatively frequent and potentially important in patients with polysplenia syndrome. Our objective was to investigate the frequency and range of portal and other abdominal systemic venous anomalies in patients with polysplenia and inferior vena cava (IVC) interruption who underwent a cavopulmonary anastomosis procedure at our center, and to review the published literature on this topic and the potential clinical importance of such anomalies. Retrospective cohort study and literature review were used. Among 77 patients with heterotaxy, univentricular heart disease, and IVC interruption who underwent a bidirectional Glenn and/or modified Fontan procedure, pulmonary arteriovenous malformations were diagnosed in 33 (43%). Bilateral superior vena cavas were present in 42 patients (55%). Despite inadequate imaging in many patients, a partial PSVC, dual IVCs, and/or renal vein anomalies were detected in 15 patients (19%). A PSVC formed by a tortuous vessel running from the systemic venous system to the extrahepatic portal vein was found in six patients (8%). Abdominal venous anomalies other than PSVC were documented in 13 patients (16%), including nine (12%) with some form of duplicated IVC system, with a large azygous vein continuing to the superior vena cava and a parallel, contralateral IVC of similar or smaller size, and seven with renal vein anomalies. In patients with a partial PSVC or a duplicate IVC that connected to the atrium, the abnormal connection allowed right-to-left shunting. PSVC and other abdominal venous anomalies may be clinically important but under-recognized in patients with IVC interruption and univentricular heart disease. In such patients, preoperative evaluation of the abdominal systemic venous system may be valuable. More data are necessary to determine whether there is a pathophysiologic connection between the polysplenia variant of heterotaxy, PSVC, and cavopulmonary anastomosis-associated pulmonary arteriovenous malformations. © 2011 Copyright the Authors. Congenital Heart Disease © 2011 Wiley Periodicals, Inc.

  19. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters

    PubMed Central

    Robinson, Ronald A; Herbertson, Luke H; Das, Srilekha Sarkar; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W

    2013-01-01

    The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body. PMID:23690701

  20. Limitations of using synthetic blood clots for measuring in vitro clot capture efficiency of inferior vena cava filters.

    PubMed

    Robinson, Ronald A; Herbertson, Luke H; Sarkar Das, Srilekha; Malinauskas, Richard A; Pritchard, William F; Grossman, Laurence W

    2013-01-01

    The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.

  1. Abnormal location of umbilical venous catheter due to Scimitar syndrome

    PubMed Central

    Mart, Christopher R; Van Dorn, Charlotte S

    2014-01-01

    Scimitar syndrome is a rare congenital anomaly where the right pulmonary veins return to the inferior vena cava (IVC) just below the diaphragm. On chest X-ray (CXR), an IVC catheter will be in a bizarre location outside the heart if it inadvertently passes into the scimitar vein rather than into the right atrium. PMID:25298705

  2. British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uberoi, Raman, E-mail: raman.Uberoi@orh.nhs.uk; Tapping, Charles Ross; Chalmers, Nicholas

    Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertionmore » and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.« less

  3. Safety and Efficacy of an Absorbable Filter in the Inferior Vena Cava to Prevent Pulmonary Embolism in Swine.

    PubMed

    Huang, Steven Y; Eggers, Mitchell; McArthur, Mark J; Dixon, Katherine A; McWatters, Amanda; Dria, Stephen; Hill, Lori R; Melancon, Marites P; Steele, Joseph R; Wallace, Michael J

    2017-12-01

    Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3). Autologous thrombus was administered from below the filter in seven swine from 0 to 35 days after filter placement. Fluoroscopy and computed tomography follow-up was performed after filter deployment from weeks 1-6 (weekly), weeks 7-20 (biweekly), and weeks 21-32 (monthly). The infrarenal IVC, lungs, heart, liver, kidneys, and spleen were harvested at necropsy. Continuous variables were evaluated with a Student t test. Results There was no evidence of IVC thrombosis, device migration, caval penetration, or pulmonary embolism. Gross pathologic analysis showed gradual device resorption until 32 weeks after deployment. Histologic assessment demonstrated neointimal hyperplasia around the IVC filter within 2 weeks after IVC filter deployment with residual microscopic fragments of polydioxanone suture within the caval wall at 32 weeks. Each iatrogenic-administered thrombus was successfully captured by the filter until resorbed (range, 1-4 weeks). Conclusion An absorbable IVC filter can be safely deployed in swine and resorbs gradually over the 32-week testing period. The device is effective for the prevention of pulmonary embolism for at least 5 weeks after placement in swine. © RSNA, 2017.

  4. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution

    PubMed Central

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-01-01

    Background Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Methods Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. Results A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. Conclusions The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. PMID:23458108

  5. The use of biological grafts for reconstruction of the inferior vena cava is a safe and valid alternative: results in 32 patients in a single institution.

    PubMed

    Pulitanó, Carlo; Crawford, Michael; Ho, Phong; Gallagher, James; Joseph, David; Stephen, Michael; Sandroussi, Charbel

    2013-08-01

    Resection and reconstruction of the inferior vena cava (IVC) is occasionally required in the surgical treatment of intra-abdominal tumours. IVC reconstruction can be performed with biological or synthetic graft material, with most centres preferring synthetic grafts. In spite of the potential advantages of biological grafts in terms of handling characteristics, and safety, very limited data are available about their use in patients requiring an IVC resection. Medical records of 32 patients who underwent an IVC resection and reconstruction from 1990 and 2011 with autogenous peritoneo-fascial (N = 22) and bovine pericardial (N = 10) grafts were reviewed. A tangential resection with patch repair was performed in 10 patients, whereas in the remaining 22 it was necessary to resect and replace a segment or all of the retrohepatic IVC. A concomitant liver resection was performed in 14 patients, nephrectomy in 10 and pancreaticoduodenectomy in 2 patients. There were no acute or late complications related to graft thrombosis or infection. Three patients died as a consequence of multi-organ failure. Overall survival at 1 and 5 years was 78% and 48%, respectively. The preferential use of synthetic grafts in IVC replacement is not evidence based. Selection of an appropriate prosthetic graft for IVC reconstruction should be based on the safety and its handling features. The use of biological grafts for IVC repair is a valid alternative to current synthetic materials and may in fact be superior in terms of biocompatability, ease of handling, reduced rate of infection and improved long-term patency without permanent anticoagulation. © 2013 International Hepato-Pancreato-Biliary Association.

  6. Detection and characterization of Budd-Chiari syndrome with inferior vena cava obstruction: Comparison of fixed and flexible delayed scan time of computed tomography venography.

    PubMed

    Zhou, Peng-Li; Wu, Gang; Han, Xin-Wei; Bi, Yong-Hua; Zhang, Wen-Guang; Wu, Zheng-Yang

    2017-06-01

    To compare the results of computed tomography venography (CTV) with a fixed and a flexible delayed scan time for Budd-Chiari syndrome (BCS) with inferior vena cava (IVC) obstruction. A total of 209 consecutive BCS patients with IVC obstruction underwent either a CTV with a fixed delayed scan time of 180s (n=87) or a flexible delayed scan time for good image quality according to IVC blood flow in color Doppler ultrasonography (n=122). The IVC blood flow velocity was measured using a color Doppler ultrasound prior to CT scan. Image quality was classified as either good, moderate, or poor. Image quality, surrounding structures and the morphology of the IVC obstruction were compared between the two groups using a χ 2 -test or paired or unpaired t-tests as appropriate. Inter-observer agreement was assessed using Kappa statistics. There was no significant difference in IVC blood flow velocity between the two groups. Overall image quality, surrounding structures and IVC obstruction morphology delineation on the flexible delayed scan time of CTV images were rated better relative to those obtained by fixed delayed scan time of CTV images (p<0.001). Evaluation of CTV data sets was significantly facilitated with flexible delayed scan time of CTV. There were no significant differences in Kappa statistics between Group A and Group B. The flexible delayed scan time of CTV was associated with better detection and more reliable characterization of BCS with IVC obstruction compared to a fixed delayed scan time. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Improving inferior vena cava filter retrieval rates with the define, measure, analyze, improve, control methodology.

    PubMed

    Sutphin, Patrick D; Reis, Stephen P; McKune, Angie; Ravanzo, Maria; Kalva, Sanjeeva P; Pillai, Anil K

    2015-04-01

    To design a sustainable process to improve optional inferior vena cava (IVC) filter retrieval rates based on the Define, Measure, Analyze, Improve, Control (DMAIC) methodology of the Six Sigma process improvement paradigm. DMAIC, an acronym for Define, Measure, Analyze, Improve, and Control, was employed to design and implement a quality improvement project to increase IVC filter retrieval rates at a tertiary academic hospital. Retrievable IVC filters were placed in 139 patients over a 2-year period. The baseline IVC filter retrieval rate (n = 51) was reviewed through a retrospective analysis, and two strategies were devised to improve the filter retrieval rate: (a) mailing of letters to clinicians and patients for patients who had filters placed within 8 months of implementation of the project (n = 43) and (b) a prospective automated scheduling of a clinic visit at 4 weeks after filter placement for all new patients (n = 45). The effectiveness of these strategies was assessed by measuring the filter retrieval rates and estimated increase in revenue to interventional radiology. IVC filter retrieval rates increased from a baseline of 8% to 40% with the mailing of letters and to 52% with the automated scheduling of a clinic visit 4 weeks after IVC filter placement. The estimated revenue per 100 IVC filters placed increased from $2,249 to $10,518 with the mailing of letters and to $17,022 with the automated scheduling of a clinic visit. Using the DMAIC methodology, a simple and sustainable quality improvement intervention was devised that markedly improved IVC filter retrieval rates in eligible patients. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  8. Pre-Clinical Model to Study Recurrent Venous Thrombosis in the Inferior Vena Cava.

    PubMed

    Andraska, Elizabeth A; Luke, Catherine E; Elfline, Megan A; Henke, Samuel P; Madapoosi, Siddharth S; Metz, Allan K; Hoinville, Megan E; Wakefield, Thomas W; Henke, Peter K; Diaz, Jose A

    2018-06-01

     Patients undergoing deep vein thrombosis (VT) have over 30% recurrence, directly increasing their risk of post-thrombotic syndrome. Current murine models of inferior vena cava (IVC) VT model host one thrombosis event.  We aimed to develop a murine model to study IVC recurrent VT in mice.  An initial VT was induced using the electrolytic IVC model (EIM) with constant blood flow. This approach takes advantage of the restored vein lumen 21 days after a single VT event in the EIM demonstrated by ultrasound. We then induced a second VT 21 days later, using either EIM or an IVC ligation model for comparison. The control groups were a sham surgery and, 21 days later, either EIM or IVC ligation. IVC wall and thrombus were harvested 2 days after the second insult and analysed for IVC and thrombus size, gene expression of fibrotic markers, histology for collagen and Western blot for citrullinated histone 3 (Cit-H3) and fibrin.  Ultrasound confirmed the first VT and its progressive resolution with an anatomical channel allowing room for the second thrombus by day 21. As compared with a primary VT, recurrent VT has heavier walls with significant up-regulation of transforming growth factor-β (TGF-β), elastin, interleukin (IL)-6, matrix metallopeptidase 9 (MMP9), MMP2 and a thrombus with high citrullinated histone-3 and fibrin content.  Experimental recurrent thrombi are structurally and compositionally different from the primary VT, with a greater pro-fibrotic remodelling vein wall profile. This work provides a VT recurrence IVC model that will help to improve the current understanding of the biological mechanisms and directed treatment of recurrent VT. Schattauer GmbH Stuttgart.

  9. Temporary Inferior Vena Cava Filters: How Do We Move Forward?

    PubMed

    Arous, Edward J; Messina, Louis M

    2016-05-01

    Despite their widespread use, the indications for the selective use of temporary inferior vena cava (IVC) filters remains uncertain with few trials supporting their use. Additionally, the risks of long-term temporary IVC filter insertion are being increasingly discussed amongst the mainstream media and through multiple class action lawsuits. Retrievable IVC filters were specifically designed to have a less secure implantation in order to facilitate retrieval. However, multiple reports have demonstrated significant filter-related complications, most commonly related to duration of implantation. Furthermore, the risk is not isolated to one manufacturer alone. The incidence of filter-related complications is linearly related to its duration of time on the market. Currently, the FDA recommends that IVC filters be removed within 25-54 days of their implantation. Unfortunately, little evidence exists to show that this recommendation is followed routinely. Recently, the PRESERVE Trial (NCT02381509) was initiated as a multicenter non-randomized open label study to determine the safety and effectiveness of commercially available IVC filters (both temporary and permanent) in individuals who require mechanical prophylaxis against pulmonary embolism. Until such evidence is developed, temporary IVC filters should be implanted based on best available evidence and routinely removed within the guidelines of the FDA of 25-54 days. A fair question at this point is whether the design features themselves that are required to manufacture a low profile removable IVC filter can achieve effective prophylaxis against pulmonary embolism at a low rate of short and long-term complications. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  10. Outcomes after inferior vena cava filter placement in cancer patients diagnosed with pulmonary embolism: risk for recurrent venous thromboembolism.

    PubMed

    Coombs, Catherine; Kuk, Deborah; Devlin, Sean; Siegelbaum, Robert H; Durack, Jeremy C; Parameswaran, Rekha; Mantha, Simon; Deng, Kathy; Soff, Gerald

    2017-11-01

    Venous thromboembolism (VTE) is a common complication in cancer patients and anticoagulation (AC) remains the standard of care for treatment. Inferior vena cava (IVC) filters may also used to reduce the risk of pulmonary embolism, either alone or in addition to AC. Although widely used, data are limited on the safety and efficacy of IVC filters in cancer patients. We performed a retrospective review of outcomes after IVC filter insertion in a database of 1270 consecutive patients with cancer-associated pulmonary embolism (PE) at our institution between 2008 and 2009. Outcomes measured included rate of all recurrent VTE, recurrent PE, and overall survival within 12 months. 317 (25%) of the 1270 patients with PE had IVC filters placed within 30 days of the index PE event or prior to the index PE in the setting of prior DVT. Patients with IVC filters had markedly lower overall survival (7.3 months) than the non-IVC filter patients (13.2 months). Filter patients also had a lower rate of AC use at time of initial PE. There was a trend towards higher recurrent VTE in patients with IVC filters (11.9%) compared to non-filter patients (7.7%), but this was not significant (p = 0.086). The risk of recurrent PE was similar between the IVC filter cohort (3.5%) and non-filter group (3.5%, p = 0.99). Cancer patients receiving IVC filters had a similar risk of recurrent PE, but a trend towards more overall recurrent VTE. The filter patients had poorer overall survival, which may reflect a poorer cancer prognosis, and had greater contraindication to AC; therefore these patients likely had a higher inherent risk for recurrent VTE. A prospective study would be helpful for further clarification on the partial reduction in the recurrent PE risk by IVC filter placement in cancer patients.

  11. Outcome of inferior vena cava and noncaval venous leiomyosarcomas.

    PubMed

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco; Pacilè, Maria Antonietta; Masci, Federica; Vietri, Francesco

    2016-02-01

    Leiomyosarcoma (LMS) is a rare tumor arising from the smooth muscle cells of arteries and veins. LMS may affect both the inferior vena cava (IVC) and non-IVC veins. Because of its rarity, the experience with the outcome of the disease originating from the IVC compared with that with non-IVC offspring is overall limited. In this study, we compared the clinical features and outcomes after operative resection of IVC and non-IVC LMS to detect possible significant differences that could affect treatment and prognosis. Twenty-seven patients undergoing operative resection of a venous LMS at a single tertiary care center and one secondary care hospital were reviewed retrospectively and divided into 2 groups: IVC-LMS (Group A, n = 18) and non-IVC LMS (Group B, n = 9). As primary end points, postoperative mortality and morbidity, disease-specific survival and, if applicable, patency of venous reconstruction were considered. Bivariate differences were compared with the χ(2) test. Disease-specific survival was expressed by a life-table analysis and compared using the log-rank test. No postoperative mortality was observed in either group. Postoperative morbidity was 28% in group A and 11% in group B (P = .33). The mean duration of follow-up was 60 months (range, 13-140). Disease-specific survival was 60% in group A and 75% in group B at 3 years (P = .48), and it was 54% in group A and 62% in group B at 5 years (P = .63). Seven grafts were occluded in group A (39%) and 1of 3 were occluded in group B (33%) (P = .85). IVC and non-IVC LMS exhibit similar outcomes in terms of postoperative course and survival. Operative resection associated with vascular reconstruction, if applicable, eventually followed by radiation and chemotherapy may be curative and is associated with good functional results. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Inferior Vena Cava Filtration in the Management of Venous Thromboembolism: Filtering the Data

    PubMed Central

    Molvar, Christopher

    2012-01-01

    Venous thromboembolism (VTE) is a common cause of morbidity and mortality. This is especially true for hospitalized patients. Pulmonary embolism (PE) is the leading preventable cause of in-hospital mortality. The preferred method of both treatment and prophylaxis for VTE is anticoagulation. However, in a subset of patients, anticoagulation therapy is contraindicated or ineffective, and these patients often receive an inferior vena cava (IVC) filter. The sole purpose of an IVC filter is prevention of clinically significant PE. IVC filter usage has increased every year, most recently due to the availability of retrievable devices and a relaxation of thresholds for placement. Much of this recent growth has occurred in the trauma patient population given the high potential for VTE and frequent contraindication to anticoagulation. Retrievable filters, which strive to offer the benefits of permanent filters without time-sensitive complications, come with a new set of challenges including methods for filter follow-up and retrieval. PMID:23997414

  13. Incidence and Outcomes of Inferior Vena Cava Filter Thrombus during Catheter-directed Thrombolysis for Proximal Deep Venous Thrombosis.

    PubMed

    Jiang, Jianguang; Tu, Jianfei; Jia, Zhongzhi; Chen, Jiezhong; Cao, Haitao; Meng, Qingli; Fuller, Tyler A; Tian, Feng

    2017-01-01

    The aim of the study was to retrospectively evaluate the incidence and outcomes of inferior vena cava (IVC) filter thrombus during catheter-directed thrombolysis (CDT) for acute proximal deep venous thrombosis (DVT). From October 2006 to June 2015, patients diagnosed with acute proximal DVT and received CDT after a retrievable IVC filter was placed were included. The incidence, treatment, and outcomes of IVC filter thrombus during CDT were recorded and analyzed. A total of 189 patients (91 women, 98 men; mean age, 57.6 ± 9.8 years; range, 24-85 years) were included in this study. Among the 189 cases, the DVTs involved popliteal iliofemoral veins in 54 patients, iliofemoral veins in 113 patients, and iliac veins in 22 patients, of which 18 patients had thrombus extended into the IVC. Of the 189 patients, a total of 8 (4.2%, 8 of 189) patients were identified with IVC filter thrombus during CDT. The IVC filter thrombus was detected on a median of 2 days (range, 2-4 days) of CDT therapy, including small-size (n = 6) and large-size (n = 2) filter thrombus. Of the 8 patients, CDTs were performed with a mean 7.6 ± 1.1 days (range, 6-11 days) after the presence of symptoms for the treatment of proximal DVT, and all the IVC filter thrombi were lysed during CDT for the proximal DVT. All the IVC filters were removed successfully with a mean of 12.8 ± 0.93 days from placement. There were no procedure- or thrombolysis-related major complications, and no symptomatic pulmonary embolism breakthrough was seen in any of the patients after the filter placement. IVC filter thrombus during CDT for the acute proximal DVT is uncommon, and all of them did not need any additional treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Leiomyosarcoma of the Inferior Vena Cava - Radical Resection, Vascular Reconstruction and Challenges: A Case Report and Review of Relevant Literature

    PubMed Central

    Biswas, Saptarshi; Amin, Arpit; Chaudry, Suhaib; Joseph, Saju

    2013-01-01

    Leiomyosarcomas of the inferior Vena Cava (IVC) are rare soft tissue sarcomas accounting for only 0.5% of all soft tissue sarcomas in adults with fewer than 300 cases reported. Extraluminal tumor growth along the adventitia of the IVC seems to be the common presentation. Intraluminal tumor growth is rare. The origin of the tumor is divided into three levels in relation to the hepatic and renal veins. The presentations and surgical modalities vary accordingly. Retroperitoneal tumors are often not diagnosed until the disease is at an advanced stage with large tumor growth and involvement of surrounding structures. This is partly because of the nonspecific clinical presentation as well as absence of early symptoms. Most patients present with abdominal or flank pain. Symptoms vary according to the dimensions of the tumor, growth pattern and localization of the tumor. Radical en bloc resection of the affected venous segment remains the only therapeutic option associated with prolonged survival. The goals of surgical management of these tumors include the achievement of local tumor control, maintenance of caval flow, and the prevention of recurrence. The involvement of renal or hepatic veins determines the strategy for vascular reconstruction. Reconstruction of the IVC is not always required, because gradual occlusion of the IVC allows the development of venous collaterals. However, when pararenal leiomyosarcoma of the IVC is present, reconstruction of the IVC and the renal vein is necessary to prevent transient or permanent renal dysfunction. Recent study has shown that radical surgery combined with adjuvant multimodal therapy has improved the cumulative survival rate. We report a case of IVC leiomyosarcoma in a young healthy woman along with details of its diagnostic workup and discussion of the surgical options and reconstruction of caval continuity. PMID:29147340

  15. Use of Cardiac Magnetic Resonance Imaging Based Measurements of Inferior Vena Cava Cross-Sectional Area in the Diagnosis of Pericardial Constriction.

    PubMed

    Hanneman, Kate; Thavendiranathan, Paaladinesh; Nguyen, Elsie T; Moshonov, Hadas; Wald, Rachel; Connelly, Kim A; Paul, Narinder S; Wintersperger, Bernd J; Crean, Andrew M

    2015-08-01

    To evaluate the value of cardiac magnetic resonance imaging (MRI)-based measurements of inferior vena cava (IVC) cross-sectional area in the diagnosis of pericardial constriction. Patients who had undergone cardiac MRI for evaluation of clinically suspected pericardial constriction were identified retrospectively. The diagnosis of pericardial constriction was established by clinical history, echocardiography, cardiac catheterization, intraoperative findings, and/or histopathology. Cross-sectional areas of the suprahepatic IVC and descending aorta were measured on a single axial steady-state free-precession (SSFP) image at the level of the esophageal hiatus in end-systole. Logistic regression and receiver-operating curve (ROC) analyses were performed. Thirty-six patients were included; 50% (n = 18) had pericardial constriction. Mean age was 53.9 ± 15.3 years, and 72% (n = 26) were male. IVC area, ratio of IVC to aortic area, pericardial thickness, and presence of respirophasic septal shift were all significantly different between patients with constriction and those without (P < .001 for all). IVC to aortic area ratio had the highest odds ratio for the prediction of constriction (1070, 95% confidence interval [8.0-143051], P = .005). ROC analysis illustrated that IVC to aortic area ratio discriminated between those with and without constriction with an area under the curve of 0.96 (95% confidence interval [0.91-1.00]). In patients referred for cardiac MRI assessment of suspected pericardial constriction, measurement of suprahepatic IVC cross-sectional area may be useful in confirming the diagnosis of constriction when used in combination with other imaging findings, including pericardial thickness and respirophasic septal shift. Copyright © 2015 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Infra-renal angles, entry into inferior vena cava and vertebral levels of renal veins.

    PubMed

    Satyapal, K S

    1999-10-01

    Current norms for renal vasculature hold true in only half the population. Standard textbooks perpetuate old misconceptions regarding renal venous anatomy. This study is aimed to determine left and right infra-renal angles (L-IRA, R-IRA); entry level of renal veins into the inferior vena cava (IVC), and height of IVC under renal vein influence; and their vertebral level. One hundred morphologically normal en-bloc renal specimens randomly selected from post-mortem examinations were dissected and resin casted. IRA were also measured from venograms of 32 adult and 11 foetal cadavers, as were vertebral entry levels. IRA measurements (degrees) were as follows: left, 55 degrees +/- 16 degrees (20 degrees -102 degrees ); right, 60 degrees +/- 17 degrees (10 degrees -93 degrees ). Left vein entered IVC higher than right 54%, lower 36%, and opposite each other 10%. Vertical distance between lower borders of veins was 1.0 +/- 0.9 cm. Vertical distance of IVC under renal vein influence was 2.3 +/- 1.0 cm. Vertebral level of veins in adults lies between TI2-L2. In foetuses, IRA was as follows: left, 65 degrees +/- 12 degrees (45 degrees -90 degrees ); right, 58 degrees +/- 7 degrees (40 degrees -70 degrees ); vertebral level between T12 and L3. Similar IRA values from literature noted on right, 51 degrees (26 degrees -100 degrees ); differences on left, 77 degrees (43 degrees -94 degrees ), clearly differing from Williams et al. (Gray's Anatomy, 37(th) ed, 1989) statement that renal veins "open into the inferior vena cava almost at right angles." Large variations of IRA are not surprising since kidneys are considered normally "floating viscera," varying position with posture and respiratory movement as well as in live vs. cadaveric subjects. The entry level into the IVC also differs from Williams et al. This study uniquely quantitated actual height difference between lower borders of left and right veins. The data presented appears to be the first documentation of vertebral level of entry of renal veins into IVC in foetuses. These findings are clinically important for the angiographer, catheter design, and planning porto-renal shunt procedures. Copyright 1999 Wiley-Liss, Inc.

  17. Inferior vena cava filter retrievals, standard and novel techniques.

    PubMed

    Kuyumcu, Gokhan; Walker, T Gregory

    2016-12-01

    The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques.

  18. Inferior vena cava filter retrievals, standard and novel techniques

    PubMed Central

    Walker, T. Gregory

    2016-01-01

    The placement of an inferior vena cava (IVC) filter is a well-established management strategy for patients with venous thromboembolism (VTE) disease in whom anticoagulant therapy is either contraindicated or has failed. IVC filters may also be placed for VTE prophylaxis in certain circumstances. There has been a tremendous growth in placement of retrievable IVC filters in the past decade yet the majority of the devices are not removed. Unretrieved IVC filters have several well-known complications that increase in frequency as the filter dwell time increases. These complications include caval wall penetration, filter fracture or migration, caval thrombosis and an increased risk for lower extremity deep vein thrombosis (DVT). Difficulty is sometimes encountered when attempting to retrieve indwelling filters, mainly because of either abnormal filter positioning or endothelization of filter components that are in contact with the IVC wall, thereby causing the filter to become embedded. The length of time that a filter remains indwelling also impacts the retrieval rate, as increased dwell times are associated with more difficult retrievals. Several techniques for difficult retrievals have been described in the medical literature. These techniques range from modifications of standard retrieval techniques to much more complex interventions. Complications related to complex retrievals are more common than those associated with standard retrieval techniques. The risks of complex filter retrievals should be compared with those of life-long anticoagulation associated with an unretrieved filter, and should be individualized. This article summarizes current techniques for IVC filter retrieval from a clinical point of view, with an emphasis on advanced retrieval techniques. PMID:28123984

  19. Post traumatic inferior vena cava thrombosis: A case report and review of literature.

    PubMed

    Chakroun, Amine; Nakhli, Mohamed Said; Kahloul, Mohamed; Harrathi, Mohamed Amine; Naija, Walid

    2017-01-01

    Post traumatic inferior vena cava (IVC) thrombosis is a rare and not well described entity with nonspecific clinical presentation. It remains a therapeutic challenge in traumatic context because of haemorrhagic risk due to anticoagulation. We report a case of IVC thrombosis in an 18 year-old man who presented with liver injury following a traffic crash. The thrombosis was incidentally diagnosed on admission by computed tomography. The patient was managed conservatively without anticoagulation initially considering the increasing haemorrhagic risk. IVC filter placing was not possible because of the unusual localization of the thrombus. Unfractionated heparin was started on the third day after CT scan control showing stability of hepatic lesions with occurrence of a pulmonary embolism. The final outcome was good. The management of post traumatic IVC thrombosis is not well described. Medical approach consists in conservative management with anticoagulation which requires the absence of active bleeding lesions. Surgical treatment is commonly based on thrombectomy under extracorporeal circulation. Interventional vascular techniques have become an important alternative approach for the treatment of many vessel lesions. Their main advantages are the relative ease and speed with which they can be performed. Post traumatic IVC thrombosis is a rare condition. Its management is not well defined. Early anticoagulation should be discussed on a case-by-case basis. Other alternatives such IVC filter or surgical thrombectomy may be used when the bleeding risk is increased. The most serious risk is pulmonary embolism. Outcome can be favorable even with non surgical approaches. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Risks and benefits of prophylactic inferior vena cava filters in patients undergoing bariatric surgery.

    PubMed

    Birkmeyer, Nancy J; Finks, Jonathan F; English, Wayne J; Carlin, Arthur M; Hawasli, Abdelkader A; Genaw, Jeffrey A; Wood, Michael H; Share, David A; Birkmeyer, John D

    2013-04-01

    The United States Food and Drug Administration recently issued a warning about adverse events in patients receiving inferior vena cava (IVC) filters. To assess relationships between IVC filter insertion and complications while controlling for differences in baseline patient characteristics and medical venous thromboembolism prophylaxis. Propensity-matched cohort study. The prospective, statewide, clinical registry of the Michigan Bariatric Surgery Collaborative. Bariatric surgery patients (n=35,477) from 32 hospitals during the years 2006 through 2012. Prophylactic IVC filter insertion. Outcomes included the occurrence of complications (pulmonary embolism, deep vein thrombosis, and overall combined rates of complications by severity) within 30 days of bariatric surgery. There were no significant differences in baseline characteristics among the 1,077 patients with IVC filters and in 1,077 matched control patients. Patients receiving IVC filters had higher rates of pulmonary embolism (0.84% vs 0.46%; odds ratio [OR], 2.0; 95% confidence interval [CI], 0.6-6.5; P=0.232), deep vein thrombosis (1.2% vs 0.37%; OR, 3.3; 95% CI, 1.1-10.1; P=0.039), venous thromboembolism (1.9% vs 0.74%; OR, 2.7; 95% CI, 1.1-6.3, P=0.027), serious complications (5.8% vs 3.8%; OR, 1.6; 95% CI, 1.0-2.4; P=0.031), permanently disabling complications (1.2% vs 0.37%; OR, 4.3; 95% CI, 1.2-15.6; P=0.028), and death (0.7% vs 0.09%; OR, 7.0; 95% CI, 0.9-57.3; P=0.068). Of the 7 deaths among patients with IVC filters, 4 were attributable to pulmonary embolism and 2 to IVC thrombosis/occlusion. We have identified no benefits and significant risks to the use of prophylactic IVC filters among bariatric surgery patients and believe that their use should be discouraged. Copyright © 2013 Society of Hospital Medicine.

  1. Predictors of Mortality in Patients with Penetrating Inferior Vena Cava Injuries Surviving to the Operating Room.

    PubMed

    Maciel, James D; Plurad, David; Gifford, Edward; deVirgilio, Christian; Koopmann, Matt; Neville, Angela; Putnam, Brant; Kim, Dennis Y

    2015-10-01

    Inferior vena cava (IVC) injuries are associated with significant morbidity and mortality. To identify clinical factors associated with mortality in patients undergoing operative intervention for penetrating IVC injuries, a retrospective review of 98 patients was performed, excluding blunt injuries (n = 20) and deaths before surgery (n = 16). The overall mortality was 58 per cent. Nonsurvivors more commonly presented with hypotension (50% vs 23%, P = 0.03) and underwent resuscitative thoracotomy more frequently (42% vs 4%, P = 0.01). Retrohepatic injuries were more common among nonsurvivors (P = 0.04). There was no difference in the use of ligation (7% vs 17%, P = 0.29) or the massive transfusion protocol (35% vs 25%, P = 0.41). On multivariate analysis, after controlling for mechanism of injury, admission hypotension, Glasgow Coma Scale score , preoperative cumulative fluids, resuscitative thoracotomy , absence of spontaneous tamponade, and location of IVC injury, the only independent predictor of mortality was the absence of spontaneous tamponade at the time of laparotomy (odds ratio = 5.4, 95% confidence interval: 1.11-25.95; P = 0.04). Penetrating IVC injuries continue to be associated with a high mortality, particularly among patients with free intraabdominal hemorrhage at laparotomy. Large multicenter studies are required to define the optimal resuscitative and operative management techniques in these severely injured patients.

  2. Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stacey, C.S., E-mail: cheika@doctors.org.uk; Manhire, A.R.; Rose, D.H.

    2004-01-15

    We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously.

  3. Successful operative treatment of uterine leiomyoma with extensive intravenous extension to the IVC, right heart, and pulmonary arteries.

    PubMed

    Brar, Ranjeet; Skervin, Alicia; El-Sakka, Karim; Fish, Andrew; Lewis, Michael

    2018-01-17

    Intravenous extension of benign uterine leiomyomata ('fibroids'), in the absence of discrete metastatic disease has rarely been reported. 'Fibroids' remain one of the most common premenopausal uterine pathologies. We report the diagnosis and multidisciplinary led operative management of a 52-year-old woman with a histologically benign, but biologically aggressive, uterine leiomyoma with intravenous extension to the inferior vena cava (IVC), right heart and pulmonary arteries. Total abdominal hysterectomy and bilateral salpingo-oophorectomy combined with exploration of the sub-hepatic IVC and heart under deep hypothermic circulatory arrest achieved its successful macroscopic clearance.

  4. Two cases of scimitar variant.

    PubMed

    Takeda, S; Imachi, T; Arimitsu, K; Minami, M; Hayakawa, M

    1994-01-01

    The scimitar sign is characteristic of partial anomalous pulmonary venous drainage into the inferior vena cava (IVC). We encountered two variant cases of scimitar sign. In one case, the scimitar vein entered both the IVC and the left atrium (LA) without any intracardiac shunts. Surgical repair was made by simple ligation of the scimitar vein to correct the left to right shunt. Retrograde balloon occlusion angiography of the scimitar vein was diagnostic. In the other case, the scimitar vein showed a meandering course, and then drained into the LA without any connection with the IVC, and surgical intervention was not required.

  5. Transfemoral Filter Eversion Technique following Unsuccessful Retrieval of Option Inferior Vena Cava Filters: A Single Center Experience.

    PubMed

    Posham, Raghuram; Fischman, Aaron M; Nowakowski, Francis S; Bishay, Vivian L; Biederman, Derek M; Virk, Jaskirat S; Kim, Edward; Patel, Rahul S; Lookstein, Robert A

    2017-06-01

    This report describes the technical feasibility of using the filter eversion technique after unsuccessful retrieval attempts of Option and Option ELITE (Argon Medical Devices, Inc, Athens, Texas) inferior vena cava (IVC) filters. This technique entails the use of endoscopic forceps to evert this specific brand of IVC filter into a sheath inserted into the common femoral vein, in the opposite direction in which the filter is designed to be removed. Filter eversion was attempted in 25 cases with a median dwell time of 134 days (range, 44-2,124 d). Retrieval success was 100% (25/25 cases), with an overall complication rate of 8%. This technique warrants further study. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  6. Retrieval of Tip-embedded Inferior Vena Cava Filters by Using the Endobronchial Forceps Technique: Experience at a Single Institution.

    PubMed

    Stavropoulos, S William; Ge, Benjamin H; Mondschein, Jeffrey I; Shlansky-Goldberg, Richard D; Sudheendra, Deepak; Trerotola, Scott O

    2015-06-01

    To evaluate the use of endobronchial forceps to retrieve tip-embedded inferior vena cava (IVC) filters. This institutional review board-approved, HIPAA-compliant retrospective study included 114 patients who presented with tip-embedded IVC filters for removal from January 2005 to April 2014. The included patients consisted of 77 women and 37 men with a mean age of 43 years (range, 18-79 years). Filters were identified as tip embedded by using rotational venography. Rigid bronchoscopy forceps were used to dissect the tip or hook of the filter from the wall of the IVC. The filter was then removed through the sheath by using the endobronchial forceps. Statistical analysis entailed calculating percentages, ranges, and means. The endobronchial forceps technique was used to successfully retrieve 109 of 114 (96%) tip-embedded IVC filters on an intention-to-treat basis. Five failures occurred in four patients in whom the technique was attempted but failed and one patient in whom retrieval was not attempted. Filters were in place for a mean of 465 days (range, 31-2976 days). The filters in this study included 10 Recovery, 33 G2, eight G2X, 11 Eclipse, one OptEase, six Option, 13 Günther Tulip, one ALN, and 31 Celect filters. Three minor complications and one major complication occurred, with no permanent sequelae. The endobronchial forceps technique can be safely used to remove tip-embedded IVC filters. © RSNA, 2014.

  7. Inferior vena cava filters in trauma patients: efficacy, morbidity, and retrievability.

    PubMed

    Smoot, Rory L; Koch, Cody A; Heller, Stephanie F; Sabater, Enrique A; Cullinane, Daniel C; Bannon, Michael P; Thomsen, Kristine M; Harmsen, William S; Baerga-Varela, Yvonne; Schiller, Henry J

    2010-04-01

    Thromboembolic events are potentially devastating sources of morbidity in trauma patients. With increasing experience and the introduction of retrievable devices, there has been a renewed interest in inferior vena cava (IVC) filters in trauma patients. The records for consecutive trauma patients undergoing IVC filter placement during the years 2001 to 2005 were reviewed, and clinical, demographic, and procedural data were evaluated for associations with thromboembolic events and device complications. During the study years, 226 trauma patients had IVC filters inserted, and 140 of these patients (62%) had retrievable IVC filters placed. Six patients (3%) had a pulmonary embolism with the filter in place, and two patients (1%) had a pulmonary embolism after filter removal. The most common complication was thrombosis in 27 patients (12%), with clinically significant thrombus occurring in 15 patients (7%). There was no association between the type of filter (permanent or retrievable) or the brand of retrievable filter and thrombosis. Specific risk factors for thrombosis could not be identified. Retrievable filters were successfully removed in 61% of patients with retrievable filters. Technical success rate was 97% in those patients who underwent attempted removal. Removal was completed at a median of 21 days (range, 2-292 days). Retrievable IVC filters in trauma patients are safe, but complications do occur with thrombosis being the most common. Retrieval has a high technical success rate when attempted. However, a significant number of trauma patients are lost to follow-up and this may impact the utilization of retrievable filters in this patient population.

  8. Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volume.

    PubMed

    Nakamura, Kensuke; Tomida, Makoto; Ando, Takehiro; Sen, Kon; Inokuchi, Ryota; Kobayashi, Etsuko; Nakajima, Susumu; Sakuma, Ichiro; Yahagi, Naoki

    2013-07-01

    Evaluation of the intravascular blood volume is an important assessment in emergency and critical care medicine. Measurement of the inferior vena cava (IVC) respiratory variation by ultrasound echography is useful, but it entails subjective problems. We have hypothesized that IVC cardiac variation is also correlated with intravascular blood volume and analyzed it automatically using computer software of two kinds, later comparing the results. Snakes, software to track boundaries by curve line continuity, and template matching software were incorporated into a computer with an ultrasound machine to track the short-axis view of IVC automatically and analyze it with approximation by ellipse. Eight healthy volunteers with temporary mild hypovolemia underwent echography before and after passive leg raising and while wearing medical anti-shock trousers. IVC cardiac variation was visually decreased by both leg raising and medical anti-shock trousers. The collapse index (maximum - minimum/maximum) of area during three cardiac beats was decreased showing a good relationship to fluid load simulations; 0.24 ± 0.03 at baseline versus 0.11 ± 0.01 with leg raising and 0.12 ± 0.01 with medical anti-shock trousers. In conclusion, IVC cardiac variation has the potential to provide an evaluation of water volume. It presents some advantages in mechanical analysis over respiratory variation. At the very least, we need to exercise some caution with cardiac variation when evaluating respiratory variation.

  9. Inferior Vena Cava Oxygen Saturation during the First Three Postnatal Days in Preterm Newborns with and without Patent Ductus Arteriosus

    PubMed Central

    Yapakçı, Ece; Ecevit, Ayşe; İnce, Deniz Anuk; Gökdemir, Mahmut; Tekindal, M. Agah; Gülcan, Hande; Tarcan, Aylin

    2014-01-01

    Background: Inferior vena cava (IVC) oxygen saturation as an indicator of mixed venous oxygenation may be valuable for understanding postnatal adaptations in newborn infants. It is unknown how this parameter progresses in critically ill premature infants. Aims: To investigate IVC oxygen saturation during the first three days of life in preterm infants with and without patent ductus arteriosus (PDA). Study Design: Case-control study. Methods: Twenty-seven preterm infants were admitted to the Neonatal Intensive Care. Preterm infants with umbilical venous catheterization were included in the study. Six umbilical venous blood gas values were obtained from each infant during the first 72 hours of life. Preterm infants in the study were divided into two groups. Haemodynamically significant PDA was diagnosed by echocardiography in 11 (41%) infants before the 72nd hour of life in the study group and ibuprofen treatment was started, whereas 16 (59%) infants who didn’t have haemodynamically significant PDA were included in the control group. Results: In the entire group, the highest value of mean IVC oxygen saturation was 79.9% at the first measurement and the lowest was 64.8% at the 72nd hour. Inferior vena cava oxygen saturations were significantly different between the study and control groups. Post-hoc analysis revealed that the first and 36th hour measurements made the difference (p=0.01). Conclusion: Inferior vena cava oxygen saturation was found to be significantly different between preterm infants with and without PDA. Further studies are needed to understand the effect of foetal shunts on venous oxygenation during postnatal adaptation in newborn infants. PMID:25337418

  10. Percutaneous closure of a hemodynamically significant connection between the inferior vena cava and the left atrium.

    PubMed

    Wiebe, Jens; Rixe, Johannes; Nef, Holger

    2015-10-01

    A connection between the inferior vena cava (IVC) and the left atrium (LA) can occur as a rare complication after surgical atrial septum defect (ASD) repair. We demonstrate the first case of a percutaneous closure of this connection. A 67-year-old female was admitted to hospital due to exertional dyspnea. A history of a surgical ASD repair in 1960 and 1966 with a residual shunt was already known. Transesophageal echocardiography and a CT scan revealed a hemodynamically significant drainage of the IVC into the LA. This connection was successfully closed percutaneously with an AMPLATEZR Duct Occluder I (St. Jude Medical, St. Paul, MN). Post-procedural CT-scan and transthoracic echocardiography demonstrated a stable position and there was also no evidence of a residual shunt. The patient reported a significant reduction of exertional dyspnea. Percutaneous closure of an IVC to LA connection in this case was safe and feasible. The decision about which device is optimal must be made on an individual basis. © 2015 Wiley Periodicals, Inc.

  11. Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharifi, Mohsen, E-mail: seyedmohsensharifi@yahoo.com; Bay, Curt; Skrocki, Laura

    Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receivemore » an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.« less

  12. Retrospective analysis of outcomes following inferior vena cava (IVC) filter placement in a managed care population.

    PubMed

    Everhart, Damian; Vaccaro, Jamieson; Worley, Karen; Rogstad, Teresa L; Seleznick, Mitchel

    2017-08-01

    The role of inferior vena cava filter (IVC) filters for prevention of pulmonary embolism (PE) is controversial. This study evaluated outcomes of IVC filter placement in a managed care population. This retrospective cohort study evaluated data for individuals with Humana healthcare coverage 2013-2014. The study population included 435 recipients of prophylactic IVC filters, 4376 recipients of therapeutic filters, and two control groups, each matched to filter recipients. Patients were followed for up to 2 years. Post-index anticoagulant use, mortality, filter removal, device-related complications, and all-cause utilization. Adjusted regression analyses showed a positive association between filter placement and anticoagulant use at 3 months: odds ratio (ORs) 3.403 (95% CI 1.912-6.059), prophylactic; OR, 1.356 (95% CI 1.164-1.58), therapeutic. Filters were removed in 15.67% of prophylactic and 5.69% of therapeutic filter cases. Complication rates were higher with prophylactic procedures than with therapeutic procedures and typically exceeded 2% in the prophylactic group. Each form of filter placement was associated with increases in all-cause hospitalization (regression coefficient 0.295 [95% CI 0.093-0.498], prophylactic; 0.673 [95% CI 0.547-0.798], therapeutic) and readmissions (OR 2.444 [95% CI 1.298-4.602], prophylactic; 2.074 [95% CI 1.644-2.616], therapeutic). IVC filter placement in this managed care population was associated with increased use of anticoagulants and greater healthcare utilization compared to controls, low rates of retrieval, and notable rates of device-related complications, with effects especially pronounced in assessments of prophylactic filters. These findings underscore the need for appropriate use of IVC filters.

  13. Inferior Vena Cava Filter Limb Fracture with Embolization to the Right Ventricle.

    PubMed

    Jackson, Bradley S; Sepula, Mykel; Marx, Jared T; Cannon, Chad M

    2017-08-01

    Inferior vena cava (IVC) filter and filter limb embolization is a known phenomenon, with a prevalence of up to 25% for certain filter types. Most commonly, the site of embolization is to the heart. Point-of-care ultrasound is an easily accessible imaging modality that should be utilized when considering IVC filter complications. A 28-year-old woman with a history of metastatic sarcoma and IVC filter placement for deep venous thrombosis presented to the Emergency Department (ED) for chest pain. Chest radiography was reviewed and originally thought to have no abnormalities. Chest computed tomography angiography was negative for filling defects or foreign bodies. A possible foreign body in the heart was noted by a radiologist's over-read of the original chest radiograph. An echocardiogram done by Cardiology was negative for foreign bodies or other abnormalities. Next, an emergency physician performed a bedside echocardiogram, with focused attention to the right side of the heart. An echogenic foreign body was visualized in the right ventricle. The patient was subsequently taken to the cardiac catheterization laboratory, where fluoroscopic visualization of a limb wire of an IVC filter within the right ventricle was obtained. That foreign body was subsequently removed successfully, along with removal of the broken IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case report highlights the utility of point-of-care ultrasound in the work-up of a patient with an embolized IVC filter wire. Chest pain patients frequently receive point-of-care echocardiography in the ED, and these ultrasound findings should be recognized and used to guide further treatment and consultation. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jha, V. M., E-mail: vjha@mfa.gwu.ed; Lee-Llacer, J.; Williams, J.

    Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not anmore » IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.« less

  15. Clinical outcome after intrahepatic venous stent placement for malignant inferior vena cava syndrome.

    PubMed

    Brountzos, Elias N; Binkert, Christoph A; Panagiotou, Irene E; Petersen, Bryan D; Timmermans, Hans; Lakin, Paul C

    2004-01-01

    We evaluated the clinical outcome of malignant inferior vena cava (IVC) syndrome after intrahepatic IVC stent placement by retrospective analysis of 50 consecutive patients (25 men, 25 women, age 32-83 years) with malignant IVC syndrome who were treated with intrahepatic stent placement. Gianturco-Rosch-Z (GRZ) stents (n = 45), and Wallstents (n = 5) were inserted. Clinical outcome was assessed from patients' records using a score based on leg swelling, scrotal/vulvar edema, ascites and anasarca before and after stent placement, as well as at last follow-up visit before death. Clinical follow-up was supplemented by duplex sonography in 36 patients. Inferior venocavography was performed in 5 patients prior to re- intervention. Follow-up time ranged from 1 to 932 days (mean 62 days). Mean pressure gradient in the IVC was reduced from 14 +/- 4.1 mmHg before to 2.9 +/- 3.2 mmHg after stent placement (p < 0.001). Four patients had stent occlusion, 2 of whom were successfully re-stented. Primary and secondary patency was 59% and 100%, respectively at 540 days. Immediate clinical data were available in 44 patients: 38 improved; 6 did not respond. Last follow-up visit data were available in 36 patients: 24 showed persistent symptom relief till death. All symptom scores were significantly improved after stent placement (p < 0.001) and with the exception of ascites, remained significantly improved (p < 0.05) until the last follow-up. Increased serum bilirubin was a common characteristic of clinical failures and recurrences. Intrahepatic IVC stent placement resulted in significant symptomatic relief in patients with malignant IVC syndrome. Palliation was effective even in patients with a very short life expectancy.

  16. Pilot in vivo study of an absorbable polydioxanone vena cava filter.

    PubMed

    Eggers, Mitchell D; McArthur, Mark J; Figueira, Tomas A; Abdelsalam, Mohamed E; Dixon, Katherine P; Pageon, Laura R; Wallace, Michael J; Huang, Steven Y

    2015-10-01

    The objectives of this study were to evaluate tensile strength retention of polydioxanone as a function of time in a swine venous system and to assess the feasibility of an absorbable inferior vena cava (IVC) filter made from polydioxanone in a pilot swine study. Twenty strands (60 cm each) of size 1 polydioxanone absorbable suture (Ethicon, Somerville, NJ) were placed in the central venous system of domestic swine. Strands were harvested at weekly intervals during 10 weeks for tensile strength testing. Results were compared with control samples obtained from an in vitro engineered circulation system containing sodium phosphate buffer solution. Three IVC filters braided from polydioxanone suture were also catheter deployed in three swine to assess absorbable IVC filter feasibility. Polydioxanone retained 82% tensile strength in vitro vs 79% in vivo at 35 days (P > .22), the desired prophylactic duration. For IVC filters made from polydioxanone, technical success of placement was achieved in all three filters deployed (100%). Autologous thrombus deployed inferior to the filter remained trapped in the filter until thrombus resorption, with no evidence of pulmonary emboli on follow-up computed tomography. There were no instances of caval penetration, filter-induced IVC thrombosis, filter migration, or tilt >15 degrees with imaging and clinical follow-up carried out to 32 weeks. Strength retention of polydioxanone suture placed in the venous system of swine is similar to earlier in vitro studies out to 10 weeks (P > .06 for all weeks) and is more than sufficient (8.20 ± 0.37 kg mean load at break for size 1) to trap thrombus. Pilot animal study suggests that an absorbable polydioxanone IVC filter can be catheter deployed to capture and to hold iatrogenically administered autologous thrombus through resorption. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  17. Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.

    PubMed

    Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro

    2017-10-01

    Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.

  18. Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com

    Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful,more » with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.« less

  19. Assessment of flow distribution in the mouse fetal circulation at late gestation by high-frequency Doppler ultrasound.

    PubMed

    Zhou, Yu-Qing; Cahill, Lindsay S; Wong, Michael D; Seed, Mike; Macgowan, Christopher K; Sled, John G

    2014-08-15

    This study used high-frequency ultrasound to evaluate the flow distribution in the mouse fetal circulation at late gestation. We studied 12 fetuses (embryonic day 17.5) from 12 pregnant CD1 mice with 40 MHz ultrasound to assess the flow in 11 vessels based on Doppler measurements of blood velocity and M-mode measurements of diameter. Specifically, the intrahepatic umbilical vein (UVIH), ductus venosus (DV), foramen ovale (FO), ascending aorta (AA), main pulmonary artery (MPA), ductus arteriosus (DA), descending thoracic aorta (DTA), common carotid artery (CCA), inferior vena cava (IVC), and right and left superior vena cavae (RSVC, LSVC) were examined, and anatomically confirmed by micro-CT. The mouse fetal circulatory system was found to be similar to that of the humans in terms of the major circuit and three shunts, but characterized by bilateral superior vena cavae and a single umbilical artery. The combined cardiac output (CCO) was 1.22 ± 0.05 ml/min, with the left ventricle (flow in AA) contributing 47.8 ± 2.3% and the right ventricle (flow in MPA) 52.2 ± 2.3%. Relative to the CCO, the flow percentages were 13.6 ± 1.0% for the UVIH, 10.4 ± 1.1% for the DV, 35.6 ± 2.4% for the DA, 41.9 ± 2.6% for the DTA, 3.8 ± 0.3% for the CCA, 29.5 ± 2.2% for the IVC, 12.7 ± 1.0% for the RSVC, and 9.9 ± 0.9% for the LSVC. The calculated flow percentage was 16.6 ± 3.4% for the pulmonary circulation and 31.2 ± 5.3% for the FO. In conclusion, the flow in mouse fetal circulation can be comprehensively evaluated with ultrasound. The baseline data of the flow distribution in normal mouse fetus serve as the reference range for future studies. Copyright © 2014 the American Physiological Society.

  20. It all unraveled from there: case report of a central venous catheter guidewire unraveling.

    PubMed

    Zerkle, Samuel; Emdadi, Vanessa; Mancinelli, Marc

    2014-12-01

    Inferior vena cava (IVC) filters can present challenges to emergency physicians in the process of central venous catheter (CVC) placement. A 68-year-old woman presented to the emergency department with severe shortness of breath and was intubated. A central line was placed after the intubation to facilitate peripheral access. A CVC guidewire unraveled during placement after getting caught on an IVC filter. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Emergency physicians should be aware of the complications that IVC filters can cause in the placement of CVCs. Imaging and identification of IVC filters beforehand will allow for proper planning of how to manage the case in which a filter catches on the guidewire. Simple anecdotal techniques, such as advancing the guidewire and spinning the guidewire between the fingers, can facilitate the removal of the guide wire from the IVC filter. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Cardiac transplantation in situs inversus: two cases reports.

    PubMed

    Chang, Y L; Wei, J; Chang, C-Y; Chuang, Y-C; Sue, S-H

    2008-10-01

    The challenge of heart transplantation in patients with situs inversus is reconstruction of the systemic venous return. Herein we have presented 2 cases of complex congenital heart disease with atriovisceral situs inversus. Both of the patients shared many common cardiac anomalies, such as a single ventricle, a single AV valve with severe regurgitation, and severe pulmonary stenosis. We completed the venous connection in 2 different ways. In the first case, the donor inferior vena cava (IVC) was anastomosed to the recipient left-sided IVC directly, making the heart slightly counterclockwise rotated. In the second case, the IVC venous reconnection was accomplished by a composite conduit made of recipient right atrium.

  2. Identifying diversion of inferior vena cava after repair of atrial septal defect.

    PubMed

    Lee, Yi Wei; Lee, Wei Chieh; Chua, Sarah

    2015-10-01

    Inadvertent IVC diversion into left atrium is a rare morbidity following ASD repair. Reported risk factors included a large secundum, or low-lying ASD, or inferior sinus venosus defect, and anomalous pulmonary connection into the RA. In our case, transesophageal echocardiogram showed abnormal connection of IVC to LA, but could not be identified owing to limited window. Cardiac CT could offer better anatomic clarification. On contrast transesophageal echocardiogram with agitated saline injected via right femoral vein, an abnormal right-to-left shunt was demonstrated by transit of microbubbles from IVC into LA, while majority of rest entered into the RA. Therefore, we confirm the IVC diversion into LA. Detection of such unusual condition is a challenge due to the fact that special echocardiographic windows are often needed.

  3. Thrombosis of the inferior vena cava and malignant disease.

    PubMed

    Kraft, Christiane; Schuettfort, Gundolf; Weil, Yvonne; Tirneci, Vanessa; Kasper, Alexander; Haberichter, Barbara; Schwonberg, Jan; Schindewolf, Marc; Lindhoff-Last, Edelgard; Linnemann, Birgit

    2014-09-01

    Inferior vena cava thrombosis (IVCT) is a rare event, and studies detailing its underlying aetiologies are scarce. One hundred and forty-one IVCT patients (57% females, median age 47 years) were analysed with a focus on malignancy-related thrombosis and compared with 141 age- and sex-matched control patients with isolated lower-extremity deep vein thrombosis. Malignancies were more prevalent among IVCT patients compared with the control group (39% vs. 7.8%; P<0.001). Malignancy-related IVCT more frequently involved the suprarenal and hepatic segments of the IVC and extended more often to the right atrium than IVCT did in non-cancer patients. Among IVCT patients with malignancies, renal cell carcinoma (38%) and other malignancies of the genitourinary tract (25%) were the most common tumours. Analysis of the underlying pathological mechanisms of malignancy-related thrombosis identified external compression of the IVC by tumour masses in 9 cases (16%), and progression of malignancy into the IVC (so-called "tumour thrombosis") in 24 cases (44%). The remaining 22 cases (40%) were attributed to malignancy-related hypercoagulability and the presence of additional venous thromboembolism risk factors, such as previous surgery, immobilisation, or chemotherapy. Malignancies substantially contribute to the risk of thrombosis involving the IVC. Tumour invasion, especially in cases of renal cell cancer and malignancy-related hypercoagulability are major triggering factors for thrombogenesis. Copyright © 2014. Published by Elsevier Ltd.

  4. Inferior vena cava thrombosis and its relationship with the JAK2V617F mutation and chronic myeloproliferative disease.

    PubMed

    Linnemann, Birgit; Kraft, Christiane; Roskos, Martin; Zgouras, Dimitrios; Lindhoff-Last, Edelgard

    2012-06-01

    Splanchnic vein thrombosis (SVT) is a typical manifestation of polycythaemia vera (PV) or essential thrombocythaemia (ET). The recently discovered JAK2V617F somatic mutation is closely associated with chronic myeloproliferative disease (CMD). We investigated whether thrombosis involving the inferior vena cava (IVC) is also related to the JAK2V617F mutation or CMD. Blood samples were obtained from 40 IVC thrombosis patients. Fifty-three patients with isolated lower extremity deep vein thrombosis (LE-DVT) and 20 SVT patients served as controls. The presence of the JAK2V617F mutation was assessed by real-time polymerase chain reaction (RT-PCR). The JAK2V617F allele was not detected in any of the IVC thrombosis patients but was detected in one patient (2%) with isolated LE-DVT. However, the mutation-carrying patient did not exhibit symptoms of CMD. Even after an observation period of 30months, the patient's complete blood cell count did not exhibit any pathology. In contrast, the JAK2V617F allele was detected in four patients with SVT (20%) and CMD. According to our data, there is no evidence that IVC thrombosis is associated with the JAK2V617F mutation or the presence of chronic myeloproliferative disease. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Characterization and Utilization of Opiate-Like Hibernation Factors.

    DTIC Science & Technology

    1993-12-08

    duodenum, and both kidneys were dissected free, along with the abdominal aorta and the inferior vena cava . The chest was then opened, and the heart, and...lungs along with the aorta and the superior and inferior vena cava (IVC), were dissected free. The trachea was transected and an endotracheal tube was...pericardial incision was extended inferiorly, exposing the anterior aspect of the left atrium and the left -Page 36 - inferior pulmonary vein. The

  6. Isolated metastases of hepatocellular carcinoma in the right atrium: Case report and review of the literature

    PubMed Central

    KAWAKAMI, MANRI; KODA, MASAHIKO; MANDAI, MARI; HOSHO, KEIKO; MURAWAKI, YOSHIKAZU; ODA, WAKAKO; HAYASHI, KAZUHIKO

    2013-01-01

    The aim of this study was to clarify the clinical features of patients with isolated HCC metastases to the heart. A 66-year-old female hospitalized with a hepatocellular carcinoma (HCC) ranging from the right to the left lobe and with a tumor thrombus in the main portal vein, was treated with intraarterial cisplatin, 5-fluouracil, adriamycin and mitomycin. Computed tomography (CT) one month later revealed that the HCC had progressed with multiple lung metastases and moderate ascites. The patient had no symptoms. Magnetic resonance imaging (MRI) and echocardiography revealed a round, movable tumor with a diameter of 2 cm in the right atrium (RA). The patient succumbed to HCC five months later. An autopsy revealed HCC with portal tumor thrombi and metastases to the lungs, inferior vena cava (IVC) and RA. The metastases in the RA and IVC were not continous with the intrahepatic tumor and were histologically attached to the endocardium and endothelium, respectively. An isolated metastasis of a HCC of the RA and IVC is extremely rare. In conclusion, although the majority of isolated metastases of HCC to the heart were diagnosed by echocardiography and were treated with mainly surgery, they had poor prognosis. The echocardiography should be performed for patients with advanced HCC. A novel treatment including molecular targeted drugs is required. PMID:23760591

  7. Current US Military Operations and Implications for Military Surgical Training

    DTIC Science & Technology

    2010-11-01

    with most procedures encountered except nephrectomy (1.5 proce- dures per resident [PPR]), craniotomy (1.1 PPRs), inferior vena cava injury (1.1 PPRs... craniotomy , IVC injury, duodenal injury, and bladder re- pair. Residents had minimal experience with external fixa- tion of skeletal injury and...vascular injury 3.5 NR Nephrectomy 3.5 1.5 Pancreatic drainage 2.8 1.9 IVC injury 2.4 1.1 Duodenal injury 2.2 0.6 NR, procedure frequency not captured

  8. Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.

    PubMed

    Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel

    2015-12-01

    We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.

  9. Unusual case of subxiphoid uniportal VATS right upper lobectomy in a patient with interrupted inferior vena cava with azygous continuation

    PubMed Central

    Abu Akar, Firas Emad; Yang, Chenlu; Zhou, Yiming; Lin, Lei; Gonzalez-Rivas, Diego

    2017-01-01

    Interrupted IVC (also known as Azygos continuation of the inferior vena cava) is a relatively uncommon congenital condition with prevalence 1.5% (0.2–3%) of the general population (Bass et al.). Although it’s usually asymptomatic condition, splenic or cardiac abnormalities could be associated (Hardwick et al.). Incidental diagnosis during prenatal ultrasound screening or by routine imaging is the most common scenario. Special attention is required during right side thoracic procedures surgical resections in order to avoid scarifying the azygos vein that could lead to fatal results (Effler et al.). We herein report a video documented case of right upper lobectomy and mediastinal lymph node dissection for non-small cell carcinoma of lung in a patient who had interrupted hepatic segmental branch of the IVC. The procedure was performed via the subxiphoid uniportal VATS approach. PMID:29078654

  10. Safe and effective treatment of early suprahepatic inferior vena caval outflow compromise following orthotopic liver transplantation using percutaneous transluminal angioplasty and stent placement.

    PubMed

    Tasse, Jordan; Borge, Marc; Pierce, Kenneth; Brems, John

    2011-01-01

    To describe the safety and efficacy of percutaneous transluminal angioplasty and stent placement in patients presenting with suprahepatic inferior vena cava (IVC) outflow compromise in the early postoperative period following orthotopic liver transplantation. Between October 2002 and April 2009, 3 patients presented with IVC outflow compromise in the first 2 months following orthotopic liver transplantation. All 3 underwent percutaneous transluminal angioplasty and stent placement without complication and showed significant clinical improvement at short and intermediate term follow-up. Percutaneous transluminal angioplasty and Gianturco stent placement is a safe and effective treatment for IVC outflow compromise in the early postoperative period following orthotopic liver transplantation.

  11. Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

    PubMed Central

    Kim, Hyoung Ook; Kim, Jae Kyu; Park, Jin Gyoon; Yim, Nam Yeol; Kang, Yang Jun; Jung, Hye Doo

    2016-01-01

    PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention. PMID:27559713

  12. Predicting inferior vena cava (IVC) filter retrievability using positional parameters: A comparative study of various filter types.

    PubMed

    Gotra, A; Doucet, C; Delli Fraine, P; Bessissow, A; Dey, C; Gallix, B; Boucher, L-M; Valenti, D

    2018-05-14

    To compare changes in inferior vena cava (IVC) filter positional parameters from insertion to removal and examine how they affect retrievability amongst various filter types. A total of 447 patients (260 men, 187 women) with a mean age of 55 years (range: 13-91 years) who underwent IVC filter retrieval between 2007-2014 were retrospectively included. Post-insertion and pre-retrieval angiographic studies were assessed for filter tilt, migration, strut wall penetration and retrieval outcomes. ANCOVA and multiple logistic regression models were used to analyze factors affecting retrieval success. Pairwise comparisons between filter types were performed. Of 488 IVC filter retrieval attempts, 94.1% were ultimately successful. The ALN filter had the highest mean absolute value of tilt (5.6 degrees), the Optease filter demonstrated the largest mean migration (-8.0mm) and the Bard G2 filter showed highest mean penetration (5.2mm). Dwell time of 0-90 days (OR, 11.1; P=0.01) or 90-180 days (OR, 2.6; P=0.02), net tilt of 10-15 degrees (OR 8.9; P=0.05), caudal migration of -10 to 0mm (OR, 3.46; P=0.03) and penetration less than 3mm (OR, 2.6; P=0.01) were positive predictors of successful retrievability. Higher odds of successful retrieval were obtained for the Bard G2X, Bard G2 and Cook Celect when compared to the ALN and Cordis Optease filters. Shorter dwell time, lower mean tilt, caudal migration and less caval wall penetration are positive predictors of successful IVC filter retrieval. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. Inferior vena cava segmentation with parameter propagation and graph cut.

    PubMed

    Yan, Zixu; Chen, Feng; Wu, Fa; Kong, Dexing

    2017-09-01

    The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of [Formula: see text], an MSD of [Formula: see text] mm, and a MaxD of [Formula: see text] mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.

  14. The Clinical Presentation, Survival Outcomes, and Management of Patients With Renal Cell Carcinoma and Cardiac Metastasis Without Inferior Vena Cava Involvement: Results From a Pooled Clinical Trial Database and Systematic Review of Reported Cases.

    PubMed

    Viteri Malone, Mariuxi A; Ares, Gustavo Ruiz; De Velasco, Guillermo; Brandão, Raphael; Lin, Xun; Norton, Craig; Simantov, Ronit; Moslehi, Javid; Krajewski, Katherine M; Choueiri, Toni K; McKay, Rana R

    2018-04-01

    Cardiac metastases from renal cell carcinoma (RCC) are uncommon and there are limited data regarding the presentation and outcomes of this population. The objective of this study was to evaluate the characteristics and outcomes of patients with RCC with cardiac metastasis without inferior vena cava (IVC) involvement. We conducted a pooled retrospective analysis of metastatic RCC patients treated in 4 clinical trials. Additionally, we conducted a systematic review of cases reported in the literature from 1973 to 2015. Patients with cardiac metastases from RCC without IVC involvement were included. Patient and disease characteristics were described. Additionally, treatments, response to therapy, and survival outcomes were summarized. Of 1765 metastatic RCC patients in the clinical trials database, 10 had cardiac metastases without IVC involvement. All patients received treatment with targeted therapy. There was 1 observed partial response (10%) and 6 patients showed stable disease (60%). The median progression-free survival was 6.9 months. The systematic review of reported clinical cases included 39 patients. In these patients, the most common cardiac site of involvement was the right ventricle (51%; n = 20). Patients were treated with medical (28%; n = 11) and/or surgical treatment (49%; n = 19) depending on whether disease was isolated (n = 13) or multifocal (n = 26). To our knowledge, this is the first series to report on the presentation and outcomes of patients with cardiac metastasis without IVC involvement in RCC. We highlight that although the frequency of patients with cardiac metastases without IVC involvement is low, these patients have a unique clinical presentation and warrant special multidisciplinary management. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Comparison of the effect of bone marrow cells infusion through the portal vein and inferior vena cava combined with short-term rapamycin on allogeneic islet grafts in diabetic rats.

    PubMed

    Gao, Qingzhen; Wang, Xiaoping; Zhang, Ruibin; Wang, Pu; Jing, Yongsheng; Ren, Wanjun; Zhu, Bin

    2016-07-01

    The study aimed to compare the impact of allogeneic bone marrow cells (BMCs) infusion through the inferior vena cava (IVC) and portal vein (PV) combined with rapamycin on allogeneic islet grafts in diabetic rats. Recipient diabetic Wistar rats were infused with islets from Sprague-Dawley rats through the PV. PKH26-labeled BMCs of Sprague-Dawley rats were infused to recipients through the PV or IVC, followed by administration of rapamycin for 4 days. Blood glucose level was measured to evaluate the survival time of the islets. Lymphocytes separated from blood, BMCs, thymus, liver, spleen and lymph node were analyzed by flow cytometry. The peripheral blood smear, BMCs smear and frozen sections of tissues were observed by a fluorescence microscope. The survival time of the islets was significantly prolonged by the BMCs infusion combined with rapamycin. The rats receiving BMCs infusion through the PV induced a significantly longer survival time of the islets, and increased mixed chimeras of allogeneic BMCs in the thymus, liver, spleen and lymph node compared with the rats receiving BMCs infusion through the IVC. The amount of the mixed chimeras on day 14 was lower than that on day 7 after islet transplantation. Furthermore, PV transplantation had significantly more mixed chimera than IVC transplantation in all analyzed organs or tissues. BMCs infusion combined with rapamycin prolongs the islets survival and induces mixed chimeras of BMCs. PV infusion of BMCs might be a more effective strategy than IVC infusion of BMCs. © 2015 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  16. Comparison of superior vena caval and inferior vena caval access using a radioisotope technique during normal perfusion and cardiopulmonary resuscitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.

    1984-10-01

    Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flowmore » or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery.« less

  17. The internal anatomy of the inferior vena cava with specific emphasis on the entrance of the renal, gonadal and lumbar veins.

    PubMed

    Bubb, Kathleen; du Plessis, Maira; Hage, Robert; Tubbs, R Shane; Loukas, Marios

    2016-01-01

    Major tributaries such as the renal and adrenal veins have been studied extensively; however, tributaries of the infra-renal segment of the inferior vena cava (IVC) have not been given much attention. Accurate knowledge of the anatomy of these veins is necessary for improved efficacy of surgical interventions in the retroperitoneum. The aim of this study therefore was to provide a comprehensive picture of the internal anatomy of the tributaries of the infra-renal segment of the IVC. Dissection of the posterior abdominal wall was performed on 30 formalin-fixed cadavers. Endoscopic study was carried out followed by a midline venotomy on the anterior wall of the isolated IVC, the location and orientation of its tributaries and their ostia were observed and measurements taken. The results showed that while there was great variation in the drainage pattern of the lumbar veins, most lumbar veins had ostia located between L2 and L3 vertebrae irrespective of the location of renal and gonadal tributaries. Valves were found in 81.81 % of gonadal veins, in 56.60 % of all lumbar veins and discrete ostial valves in 14.81 % of renal veins. The location of the tributaries of the IVC was correlated with the vertebral levels. Empirical data regarding their ostio-valvular complexes were established, which put into question widely accepted concept of valveless tributaries. Our results may implicate surgical procedures in and around the retroperitoneal region.

  18. International Shock Congress (1st) and Annual Society Meeting (10th) Held in Montreal, Canada on 7-11 June 1987

    DTIC Science & Technology

    1987-10-01

    demonstrated that endotoxin shock is associated with a decrease in compliance of the superior and inferior vena cavae and probably £ Abstracts 17 central...site of a burn wound. METHODS: Anesthetized 350 gram male Long Evans rats were prepared by intrarenal inferior vena cava (IVC) ligation. The rats...elastase has been investigated in the superior vena caval and left atrium blood collected from 167 patients who underwent open heart surgery. The effect

  19. Blocking of the Hepatic Vein Outflow by Neointima Covering a Wallstent Across a Membranous Stenosis of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dutta, Usha; Garg, Pramod K.; Agarwal, Rajeev

    1999-11-15

    A 31-year-old man presented with idiopathic membranous obstruction of the suprahepatic inferior vena cava (IVC) and was treated by balloon dilation and placement of a Wallstent. The patient improved markedly. However, he developed obstruction of the hepatic vein outflow secondary to neointima formation over the stent that covered the hepatic vein ostia. The patient died of liver failure and septicemia. We believe that this is the first report of such a serious complication.

  20. Combined liver resection and reconstruction of the supra-renal vena cava: the Paul Brousse experience.

    PubMed

    Azoulay, Daniel; Andreani, Paola; Maggi, Umberto; Salloum, Chadi; Perdigao, Fabiano; Sebagh, Mylène; Lemoine, Antoinette; Adam, René; Castaing, Denis

    2006-07-01

    Liver tumors with inferior vena cava (IVC) involvement may require combined resection of the liver and IVC. This approach, with its high surgical risks and poor long-term prognosis, was precluded until the development of neoadjuvant chemotherapy, portal vein embolization, reinforced vascular prostheses, and technical advances in liver transplantation. We reviewed 22 cases of hepatectomy with retrohepatic IVC resection and reconstruction. The patients had a median age of 51.5 years (range, 32.8-75.3 years). Indications for resection were: liver metastases (n = 9), cholangiocarcinoma (n = 8), hepatocellular carcinoma (n = 2), other cancers (n = 3). The liver resections carried out included 18 first, 3 second, and one third hepatectomy. Segment 1 (caudate lobe) was included in the specimen in 19 cases (86%). Resection concerned 1 to 6 liver segments (median = 5.0). Vascular control was achieved by vascular exclusion of the liver preserving the caval flow (n = 1), standard vascular exclusion of the liver (n = 12), in situ cold perfusion of the liver (n = 9). Ex situ surgery was not necessary in any case. Venovenous bypass was used in 12 cases. The IVC was reconstructed with a ringed Gore-Tex tube graft (n = 10), primarily (n = 8), or by caval plasty (n = 4). A main hepatic vein was reimplanted in 6 cases: into the native IVC (n = 4) or into a Gore-Tex tube graft (n = 2). One patient died (4.5%) due to catheter infection, 7 days after in situ cold perfusion with replacement of the vena cava. Eight patients (36%) had no complications and 14 patients (64%) had 23 complications. In all but 1 case, the complications were transient and successfully controlled. The patients stayed in intensive care for 3.3 +/- 2.0 days and in the hospital for 17.7 +/- 7.8 days. All vascular reconstructions were patent at last follow-up. With median follow-up of 19 months, 10 patients died of tumor recurrence and eleven were alive with (n = 5) or without (n = 6) disease. Actuarial 1-, 3-, and 5-year survival rates were 81.8%, 38.3%, and 38.3%, respectively. IVC resection and reconstruction combined with liver resection can be safely performed in selected patients. The lack of alternative treatments and the spontaneous poor prognosis justify this approach, provided that surgery is carried out at a center specialized in both liver surgery and liver transplantation. The development of adjuvant chemotherapy regimens is required to improve the long-term results of this salvage surgery.

  1. A rare nidus for pulmonary thromboembolism after vertebroplasty.

    PubMed

    Vallabhajosyula, Saraschandra; Sundaragiri, Pranathi Rao; Bansal, Ojas; Townley, Theresa A

    2013-10-23

    Percutaneous vertebroplasty is used to treat osteoporotic compression fractures and bone loss due to malignancy. The cement used can serve as a potential nidus for pulmonary thromboembolism (PTE). An 87-year-old woman with recent L2 vertebroplasty presented with abdominal pain and shortness of breath. Thoracoabdominal CT scan revealed extensive bilateral pulmonary emboli associated with a 9 cm cement fragment in the inferior vena cava (IVC) extending proximally from the level of the right superior renal vein, likely secondary to cement leak from the vertebral plexus into the IVC. She refused catheter extraction was managed conservatively. There are 51 reported cases of cement pulmonary embolism. IVC foreign bodies serving as a nidus for PTE have been reported with IVC filters with an incidence of 6.2%. This is the second reported case of vertebroplasty cement serving as a nidus for PTE. Treatment depends on time interval between the procedure and the symptom onset.

  2. Robotic-Assisted Inferior Vena Cava Filter Retrieval.

    PubMed

    Owji, Shahin; Lu, Tony; Loh, Thomas M; Schwein, Adeline; Lumsden, Alan B; Bismuth, Jean

    2017-01-01

    Although anticoagulation remains the mainstay of therapy for patients with venous thromboembolism, guidelines recommend the use of inferior vena cava (IVC) filters in those who fail anticoagulation or have contraindications to its use. Short-term use of filters has proven effective in reducing the rate of pulmonary embolism. However, their extended use is associated with a variety of complications such as thrombosis, filter migration, or caval perforation, thus making a case for timely filter retrieval. This is the case of a 68-year-old female with a history of chronic oral anticoagulation use for multiple deep venous thrombi (DVT) and pulmonary emboli (PE) who required cervical and thoracic spinal intervention for spondylosis and foramina stenosis. Given her increased risk of recurrent DVT and PE perioperatively, we elected to place a Cook Celect ™ IVC filter (Cook Medical, Bloomington, IN) after oral anticoagulation was stopped for the procedure. Her treatment course was prolonged due to wound-healing complications. We elected to use the Magellan Robotic Catheter System (Hansen Medical, Mountain View, CA) for filter retrieval when she presented 6 months later with caval perforation from the filter struts. With its ease of use, superior mechanical stability, and maneuverability, robot-assisted IVC filter retrieval may be a safer and more reliable substitute for traditional navigation techniques when presented with challenging filter retrievals.

  3. Experimental measurements of energy augmentation for mechanical circulatory assistance in a patient-specific Fontan model.

    PubMed

    Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L

    2014-09-01

    A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  4. SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melancon, A; Jacobsen, M; Salatan, F

    Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GEmore » Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.« less

  5. Long-Term Safety and Effectiveness of the 'OptEase' Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalva, Sanjeeva P., E-mail: skalva@partners.org; Marentis, Theodore C.; Yeddula, Kalpana

    Purpose: To assess the long-term safety and effectiveness of the OptEase inferior vena cava (IVC) filter. Materials and Methods: In this Institutional Review Board-approved, retrospective study, we reviewed data of 71 patients who received an OptEase filter at our institution from 2002 to 2007. Thirty-nine (55%) patients had symptoms of venous thromboembolism before filter placement. The indications for filter included contraindication to anticoagulation in 31 (44%) patients, prophylaxis against pulmonary embolism (PE) in 29 (41%) patients, and failure of anticoagulation in 11 (15%) patients. Procedure-related complications, such as symptomatic post-filter PE, deep venous thrombosis (DVT), IVC occlusion, and incidental imaging-evidentmore » filter-related complications, were recorded. Safety was assessed by the occurrence of filter-related complications during placement and follow-up. Effectiveness was assessed by the occurrence of post-filter PE. Results: Sixty-five (92%) filters were placed under fluoroscopy, and 6 (8%) were placed using intravascular ultrasound guidance. Seventy (99%) filters were placed successfully. Seven (10%) filters were placed in the suprarenal cava. Retrieval was attempted in 14 (20%) patients, and 12 filters were successfully retrieved. Clinical follow-up was available for 20 {+-} 21 months. Symptoms of postfilter PE and DVT occurred in 15% (n = 11) and 10% (n = 7) patients, respectively. None of these patients had computed tomography (CT)-proven PE, and only one had ultrasound-proven new DVT. One patient had symptomatic IVC occlusion. Follow-up abdominal CT in 20 patients showed thrombus in the filter in two of them. There were no instances of filter migration, filter tilt, or caval wall penetration. Conclusion: The OptEase filter appears to have an acceptable long-term safety profile. The filter was effective against PE.« less

  6. Peroperative electrocardiographic control of catheter tip position during implantation of femoral venous ports.

    PubMed

    Gibault, Pierre; Desruennes, Eric; Bourgain, Jean-Louis

    2015-01-01

    Electrocardiographic (ECG) guidance has been shown to be as effective than fluoroscopy to position the tip of central venous devices close to the superior vena cava (SVC)-right atrium (RA) junction. When SVC access is contraindicated, a femoral access may be used. The aim of this prospective study is to evaluate the effectiveness of ECG guidance to position the tip of femoral ports at inferior vena cava (IVC)-RA junction. Inclusion criterion was the need for femoral port implantation. After insertion of the dilator in the femoral vein, the catheter with the guide wire inside was introduced and the ECG signal collected at the tip of the guide (Celsite™ ECG, B. Braun, Germany) or via saline injected in the catheter (Nautilus™, Perouse, France). Fluoroscopy was performed at each change of the P-wave from IVC to RA. A final X-ray was performed after withdrawing the catheter 2 cm below the first P-wave change. A total of 18 patients were included between December 2011 and June 2013. The P-wave was most often negative in IVC, biphasic when the catheter entered RA and giant and positive at the top of RA. When the catheter was withdraw 2 cm below the first biphasic P-wave the tip was just below the IVC-RA junction in 17 patients. In one patient P-wave changes were not significant and the final position was adjusted under fluoroscopy. ECG guidance is effective to assess catheter tip position during femoral port placement and avoids the need for radiological methods.

  7. Outcome of Resection and Chemotherapy versus Chemotherapy Alone for Retroperitoneal Recurrence of Testicular Cancer Involving the Inferior Vena Cava: A Retrospective Cohort Study of 22 Consecutive Patients.

    PubMed

    Illuminati, Giulio; Calio, Francesco G; Angelici, Alberto M; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Vietri, Francesco

    2016-07-01

    Optimal treatment strategy for retroperitoneal recurrence of testicular cancer involving the inferior vena cava (IVC) is uncertain. The purpose of this study was to validate the hypothesis that surgical resection, en-bloc with the involved segment of IVC and its subsequent reconstruction followed by chemotherapy, would yield better oncologic results than chemotherapy alone. Two consecutive series of patients with retroperitoneal recurrence of testicular cancer involving the IVC, treated with surgical resection plus chemotherapy (group A, n=14) or chemotherapy alone (group B, n=8) were retrospectively reviewed. The mean duration of follow-up was was 65 months (range=8-184). Operative mortality and morbidity in group A, response to chemotherapy in group B, disease-specific survival and quality adjusted life-years (QALY) for both groups, were primary end-points of the study. Postoperative mortality and morbidity (group A) were, respectively, nil and 14%. In group B, two patients (25%) fully responded to chemotherapy and remained free from disease progression. Disease-specific survival at 3 and 5 years was 81% and 54% in group A and 36% in group B both at 3 and 5 years, respectively (p=0.02). QALY was 3.92 in group A and 0.77 for both 3 and 5 years in group B, respectively, (p=0.031). En bloc resection of retroperitoneal recurrence of testicular tumors invading the IVC, followed by chemotherapy, allows a better survival rate compared to chemotherapy alone. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  8. Strategies for prevention of iatrogenic inferior vena cava filter entrapment and dislodgement during central venous catheter placement.

    PubMed

    Wu, Alex; Helo, Naseem; Moon, Eunice; Tam, Matthew; Kapoor, Baljendra; Wang, Weiping

    2014-01-01

    Iatrogenic migration of inferior vena cava (IVC) filters is a potentially life-threatening complication that can arise during blind insertion of central venous catheters when the guide wire becomes entangled with the filter. In this study, we reviewed the occurrence of iatrogenic migration of IVC filters in the literature and assessed methods for preventing this complication. A literature search was conducted to identify reports of filter/wire entrapment and subsequent IVC filter migration. Clinical outcomes and complications were identified. A total of 38 cases of filter/wire entrapment were identified. All of these cases involved J-tip guide wires. Filters included 23 Greenfield filters, 14 VenaTech filters, and one TrapEase filter. In 18 cases of filter/wire entrapment, there was migration of the filter to the heart and other central venous structures. Retrieval of the migrated filter was successful in only four of the 18 cases, and all of these cases were complicated by strut fracture and distant embolization of fragments. One patient required resuscitation during retrieval. Successful disengagement was possible in 20 cases without filter migration. Iatrogenic migration of an IVC filter is an uncommon complication related to wire/filter entrapment. This complication can be prevented with knowledge of the patient's history, use of proper techniques when placing a central venous catheter, identification of wire entrapment at an early stage, and use of an appropriate technique to disengage an entrapped wire. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, Richard A.; Teitelbaum, George P.; Stanley, Philip

    Purpose: To report our experience with inferior vena cava (IVC) filters in pediatric patients. Methods: Over a 19-month period, eight low-profile percutaneously introducible IVC filters were placed in four male and four female patients aged 6-16 years (mean 11 years). Indications were contraindication to heparin in six patients, anticoagulation failure in one, and idiopathic infrarenal IVC thrombosis in one. Six of the eight devices placed were titanium Greenfield filters. One LGM and one Bird's Nest filter were also placed. Two of the filters were introduced via the right internal jugular vein by cutdown, and the remainder were placed percutaneously viamore » the right internal jugular vein or the right common femoral vein. Patients received follow-up abdominal radiographs from 2 to 13 months after IVC filter placement. Results: All filters were inserted successfully without complication. Three of the patients died during the follow-up period: two due to underlying brain tumors at 2 and 12 months and a third at 6 weeks due to progressive idiopathic renal vein and IVC thrombosis. The remaining five patients were all alive and well at follow-up without evidence of IVC thrombosis, pulmonary emboli, or filter migration. Conclusion: IVC filter placement using available devices for percutaneous delivery is technically feasible, safe, and effective in children.« less

  10. Outcomes of Stent Placement for Chronic Occlusion of a Filter-bearing Inferior Vena Cava in Patients with Severe Post-thrombotic Syndrome.

    PubMed

    Ye, K; Lu, X; Li, W; Yin, M; Liu, X; Qin, J; Liu, G; Jiang, M

    2016-12-01

    To evaluate the technical aspects and short-term clinical results of stent placement for chronic occlusion of a filter-bearing inferior vena cava (IVC) in patients with severe post-thrombotic syndrome (PTS). A retrospective analysis of 24 patients with severe PTS associated with occlusion of a filter-bearing IVC treated by stent placement was conducted at a single institution from January 2010 to December 2014. Patient-reported quality of life and limb Villalta scores were evaluated before and after treatment by questionnaire and clinical examination, respectively. Stent patency was evaluated by duplex Doppler ultrasound, venography, or venous computed tomographic (CT) angiography. All patients tolerated the procedure well. Nineteen patients with filter-bearing IVC and bilateral iliofemoral occlusions were treated with "double-barrel" stents, two were treated with fenestrated stents, and the remaining three patients were treated by unilateral stent placement of the iliofemoral vein and filter-bearing IVC. Quality of life and Villalta scores were significantly improved (p < .001) after the procedure. The 1-year, and 2-year cumulative primary and secondary stent patency rates were 67% and 91%, and 45% and 77%, respectively. During a median follow-up period of 27 months (range 3-55 months), the cumulative rates of complete relief of pain (visual analog scale >5) and swelling (grade 3) were 77% (13 of 17 limbs at risk) and 75% (24 of 32 limbs at risk), respectively. There were 23 limbs with active ulcers and the cumulative rate of ulcer healing at 2 years was 73%. There were no cases of clinical bleeding, symptomatic pulmonary embolism, or mortality. Recanalization of an occluded IVC filter and stent placement through the filter is a feasible and safe method for management of PTS associated with filter-bearing IVC occlusions, with acceptable short-term stent patency and clinical results. However, close follow-up after procedure is necessary because of a relatively high re-occlusion rate. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  11. Complications and Retrieval Data of Vena Cava Filters Based on Specific Infrarenal Location.

    PubMed

    Tullius, Thomas G; Bos, Aaron S; Patel, Mikin V; Funaki, Brian; Van Ha, Thuong G

    2018-02-01

    Although recommended placement of IVC filters is with their tips positioned at the level of the renal vein inflow, in practice, adherence is limited due to clinical situation or IVC anatomy. We seek to evaluate the indwelling and retrieval complications of IVC filters based on their specific position within the infrarenal IVC. Retrospective, single institution study of 333 consecutive infrarenal vena cava filters placed by interventional radiologists in patients with an average age of 62.2 ± 15.7 years was performed between 2013 and 2015. Primary indication was venous thromboembolic disease (n = 320, 96.1%). Filters were classified based on location of the apex below the lowest renal vein inflow on the procedural venogram: less than 1 cm (n = 180, 54.1%), 1-2 cm (n = 96, 28.8%), and greater than 2 cm (n = 57, 17.1%). Denali (n = 171, 51.4%) and Celect (n = 162, 48.6%) filters were evaluated. CT follow-up, indwelling complications, and retrieval data were obtained. Follow-up CT imaging performed for symptomatic indications occurred for 38.3% of filters placed < 1 cm below the lowest renal vein, 27.1% of filters placed 1-2 cm, and 36.8% placed > 2 cm (p = .16). There was no difference in caval strut penetration, penetration of adjacent viscera, time to penetration, filter migration, or tilt (p = .15, .27, .41, .57, .93). No filter fractures occurred. There was no difference in the incidence of breakthrough PE or complex filter retrieval (p = .83, .59). Only one retrieval failure occurred. This study suggests filter apex location within the infrarenal IVC, including placement > 2 cm below the level of the renal vein inflow, is not associated with differences in indwelling or retrieval complications. Level 3 non-randomized controlled follow-up study.

  12. Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pellerin, O., E-mail: olivier.pellerin@egp.aphp.f; Barral, F. G.; Lions, C.

    Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 {+-} 15 days (range, 6-722 days)more » through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.« less

  13. The electrolytic inferior vena cava model (EIM) to study thrombogenesis and thrombus resolution with continuous blood flow in the mouse

    PubMed Central

    Diaz, Jose A.; Alvarado, Christine M.; Wrobleski, Shirley K.; Slack, Dallas W.; Hawley, Angela E.; Farris, Diana M.; Henke, Peter K.; Wakefield, Thomas W.; Myers, Daniel D.

    2016-01-01

    Summary Previously, we presented the electrolytic inferior vena cava (IVC) model (EIM) during acute venous thrombosis (VT). Here, we present our evaluation of the EIM for chronic VT time points in order to determine whether this model allows for the study of thrombus resolution. C57BU6 mice (n=191) were utilised. In this model a copper-wire, inserted into a 25-gauge needle, is placed in the distal IVC and another subcutaneously. An electrical current (250 µAmp/15 minutes) activates the endothelial cells, inducing thrombogenesis. Ultrasound, thrombus weight (TW), vein wall leukocyte counts, vein wall thickness/fibrosis scoring, thrombus area and soluble P-selectin (sP-sel) were performed at baseline, days 1, 2, 4, 6, 9, 11 and 14, post EIM. A correlation between TW and sP-sel was also determined. A thrombus formed in each mouse undergoing EIM. Blood flow was documented by ultrasound at all time points. IVC thrombus size increased up to day 2 and then decreased over time, as shown by ultrasound, TW, and sP-sel levels. TW and sP-sel showed a strong positive correlation (r=0.48, p<0.0002). Vein wall neutrophils were the most common cell type present in acute VT (up to day 2) with monocytes becoming the most prevalent in chronic VT (from day 6 to day 14). Thrombus resolution was demonstrated by ultrasound, TW and thrombus area. In conclusion, the EIM produces a non-occlusive and consistent IVC thrombus, in the presence of constant blood flow, allowing for the study of VT at both acute and chronic time points. Thrombus resolution was demonstrated by all modalities utilised in this study. PMID:23571406

  14. Thrombogenesis with continuous blood flow in the inferior vena cava. A novel mouse model.

    PubMed

    Diaz, José A; Hawley, Angela E; Alvarado, Christine M; Berguer, Alexandra M; Baker, Nichole K; Wrobleski, Shirley K; Wakefield, Thomas W; Lucchesi, Benedict R; Myers, Daniel D

    2010-08-01

    Several rodent models have been used to study deep venous thrombosis (DVT). However, a model that generates consistent venous thrombi in the presence of continuous blood flow, to evaluate therapeutic agents for DVT, is not available. Mice used in the present study were wild-type C57BL/6 (WT), plasminogen activator inhibitor-1 (PAI-1) knock out (KO) and Delta Cytoplasmic Tail (DCT). An electrolytic inferior vena cava (IVC) model (EIM) was used. A 25G stainless-steel needle, attached to a silver coated copper wire electrode (anode), was inserted into the exposed caudal IVC. Another electrode (cathode) was placed subcutaneously. A current of 250 muAmps over 15 minutes was applied. Ultrasound imaging was used to demonstrate the presence of IVC blood flow. Analyses included measurement of plasma soluble P-selectin (sP-Sel), thrombus weight (TW), vein wall morphometrics, P-selectin and Von Willebrand factor (vWF) staining, transmission electron microscopy (TEM), scanning electron microscopy (SEM); and the effect of enoxaparin on TW was evaluated. A current of 250 muAmps over 15 minutes consistently promoted thrombus formation in the IVC. Plasma sP-Sel was decreased in PAI-1 KO and increased in DCT vs. WT (WT/PAI-1: p=0.003, WT/DCT: p=0.0002). Endothelial activation was demonstrated by SEM, TEM, P-selectin and vWF immunohistochemistry and confirmed by inflammatory cell counts. Ultrasound imaging demonstrated thrombus formation in the presence of blood flow. Enoxaparin significantly reduced the thrombus size by 61% in this model. This EIM closely mimics clinical venous disease and can be used to study endothelial cell activation, leukocyte migration, thrombogenesis and therapeutic applications in the presence of blood flow.

  15. Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI

    PubMed Central

    Jarvis, Kelly; Schnell, Susanne; Barker, Alex J.; Garcia, Julio; Lorenz, Ramona; Rose, Michael; Chowdhary, Varun; Carr, James; Robinson, Joshua D.; Rigsby, Cynthia K.; Markl, Michael

    2016-01-01

    Background Asymmetrical caval to pulmonary blood flow is suspected to cause complications in patients with Fontan circulation. The aim of this study was to test the feasibility of 4-D flow MRI for characterizing the relationship between 3-D blood flow distribution and vascular geometry. Objective We hypothesized that both flow distribution and geometry can be calculated with low interobserver variability and will detect a direct relationship between flow distribution and Fontan geometry. Materials and methods Four-dimensional flow MRI was acquired in 10 Fontan patients (age: 16±4 years [mean ± standard deviation; range 9–21 years]). The Fontan connection was isolated by 3-D segmentation to evaluate flow distribution from the inferior vena cava (IVC) and superior vena cava (SVC) to the left and right pulmonary arteries (LPA, RPA) and to characterize geometry (cross-sectional area, caval offset, vessel angle). Results Flow distribution results indicated SVC flow tended toward the RPA while IVC flow was more evenly distributed (SVC to RPA: 78%±28 [9–100], IVC to LPA: 54%±28 [4–98]). There was a significant relationship between pulmonary artery cross-sectional area and flow distribution (IVC to RPA: R2=0.50, P=0.02; SVC to LPA: R2=0.81, P=0.0004). Good agreement was found between observers and for flow distribution when compared to net flow values. Conclusion Four-dimensional (4-D) flow MRI was able to detect relationships between flow distribution and vessel geometry. Future studies are warranted to investigate the potential of patient specific hemodynamic analysis to improve diagnostic capability. PMID:27350377

  16. Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Izaki, Kenta, E-mail: izaki@med.kobe-u.ac.jp; Yamaguchi, Masato; Matsumoto, Ippei

    2011-06-15

    A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas-kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor's portal vein was anastomosed to the recipient's inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our techniquemore » for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.« less

  17. Percutaneous Retrieval of Permanent Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu; Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu; Holly, Brian, E-mail: bholly3@jhmi.edu

    PurposeTo evaluate the feasibility, risks, and techniques of percutaneous removal of permanent TrapEase and Simon Nitinol IVC filters.Materials and MethodsBetween August 2011 and August 2015, 12 patients (5 women, 7 men; age range, 26–75 years) underwent an attempt at percutaneous removal of permanent TrapEase (10) and Simon Nitinol (2) IVC filters due to a history of IVC filter complications or need for lifelong anticoagulation due to the filter. Medical records were reviewed for filter dwell time, presence of iliocaval deep venous thrombosis, procedural technique, and complications.ResultsFilter dwell times ranged from 7 days to 15 years (mean 5.1 years). Successful removal of permanent IVC filtersmore » was possible in 11 of 12 patients (91.6 %). In 1 patient, a chronically thrombosed IVC filter could not be removed despite laser sheath assistance, but was successfully recanalized with the PowerWire RF guidewire. In the failed retrieval attempt, a stent was placed through the chronically thrombosed IVC filter with restoration of in-line flow. One major complication of large venous groin hematoma was encountered.ConclusionsIn carefully selected patients, percutaneous removal of permanent IVC filters can be performed safely despite prolonged filter dwell times. Extraction of chronically embedded permanent IVC filters may be facilitated by jugular and femoral approaches, often with laser sheath assistance. Chronic filter thrombosis and caval scarring may increase the risk of retrieval failure.« less

  18. Twin Valve Caval Stent for Functional Replacement of Incompetent Tricuspid Valve: A Feasibility Animal Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sochman, Jan, E-mail: jan.sochman@medicon.cz; Peregrin, Jan H., E-mail: jape@medicon.cz; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu

    Objective: To evaluate feasibility of a twin valve caval stent (TVCS) for functional replacement of an incompetent tricuspid valve (TV) in an acute animal study. Methods: One swine and three sheep were used in the study. TVCS placement was tested in a swine with a normal TV. TVCS function was tested in three sheep with TV regurgitation created by papillary muscle avulsion. Cardiac angiograms and pressure measurements were used to evaluate TVCS function. Two sheep were studied after fluid overload. Results: TVCS was percutaneously placed properly at the central portions of the superior vena cava (SVC) and inferior vena cavamore » (IVC) in the swine. Papillary muscle avulsion in three sheep caused significant tricuspid regurgitation with massive reflux into the right atrium (RA) and partial reflux into the SVC and IVC. TVCS placement eliminated reflux into the SVC and IVC. After fluid overload, there was enlargement of the right ventricle and RA and significant increase in right ventricle, RA, SVC, and IVC pressures, but no reflux into the IVC and SVC. Conclusion: The results of this feasibility study justify detailed evaluation of TVCS insertion for functional chronic replacement of incompetent TV.« less

  19. Primary Renal Rhabdomyosarcoma in an Adolescent With Tumor Thrombosis in the Inferior Vena Cava and Right Atrium: A Case Report and Review of the Literature.

    PubMed

    Lin, Wei-Ching; Chen, Jeon-Hor; Westphalen, Antonio; Chang, Han; Chiang, I-Ping; Chen, Cheng-Hong; Wu, Hsi-Chin; Lin, Chien-Heng

    2016-05-01

    Although the second peak of the age distribution of rhabdomyosarcoma (RMS) is at adolescence, renal RMS is extremely rare at this age group. This tumor is indistinguishable from other renal tumors based on clinical and imaging findings, and the diagnosis relies on histology and immunohistochemical staining. We report a unique case of adolescent renal RMS associated with tumor thrombus extending into the inferior vena cava (IVC) and right atrium.An 18-year-old female adolescent presented with shortness of breath and palpitations, associated with right flank discomfort, and hematuria. A pleomorphic-type renal RMS with Budd-Chiari syndrome and arrhythmia induced by IVC and RA thrombosis was diagnosed. Despite complete tumor resection, the patient developed multiple lung metastases a month after surgery. Chemotherapy was recommended, but the patient declined. She died within a year of the initial operation.Adolescent renal RMS is rare and associated with poor outcome. Early aggressive multimodal therapy seems to be appropriate, in particular, in the presence of tumor thrombosis.

  20. KILT (Kidney and IVC Abnormalities with Leg Thrombosis) Syndrome in a 41-Years-Old Man with Loin Pain and Fever.

    PubMed

    Fung, James Kiujing; Yeung, Victor Hip Wo; Chu, Sau Kwan; Man, Chi Wan

    2017-05-01

    KILT syndrome is a rare condition composing the triad of kidney and inferior vena cava anomaly and extensive venous thrombosis. We present a case of newly diagnosed KILT syndrome in a 41-years-old gentleman presenting with loin pain and fever. Reviewing previous case reports, KILT syndrome is usually an incidental finding on imaging studies and there is a wide scope of initial clinical presentations. However, recent evidence suggests IVC anomaly may have caused subsequent renal hypoplasia. Identification of the underlying etiology may be helpful in planning early vascular intervention to treat the condition.

  1. Severe cyanosis after Kawashima operation resulting from congenital portosystemic shunt.

    PubMed

    Nakamura, Yuki; Aoki, Mitsuru; Hagino, Ikuo; Nakajima, Hiromichi

    2012-04-01

    We describe an unusual case of a patient with polysplenia, inferior vena cava (IVC) interruption, and unrecognized congenital portosystemic venous connection (CPVC) in whom severe cyanosis developed in the acute postoperative stage after a Kawashima operation and required urgent surgical division of the CPVC. It has been stressed recently that CPVCs and other abdominal venous abnormalities have been underdiagnosed in patients with polysplenia and IVC interruption, and we think that a routine evaluation of abdominal venous connections should be mandatory before considering the Kawashima operation for these patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Combined Resection of the Liver and Inferior Vena Cava for Hepatic Malignancy

    PubMed Central

    Hemming, Alan W.; Reed, Alan I.; Langham, Max R.; Fujita, Shiro; Howard, Richard J.

    2004-01-01

    Objective: The objective of this paper is to review the results of combined resection of the liver and inferior vena cava for hepatic malignancy. The morbidity and mortality along with preliminary survival data are assessed in order to determine the utility of this aggressive approach to otherwise unresectable tumors. Summary Background Data: Involvement of the inferior vena cava has traditionally been considered a contraindication to resection for advanced tumors of the liver because the surgical risks are high and the long-term prognosis is poor. Progress in liver surgery allows resection in some cases. Methods: Twenty-two patients undergoing hepatic resection from 1997 to 2003, that also required resection and reconstruction of the inferior vena cava (IVC), were reviewed. The median age was 49 years (range 2 to 68 years). Resections were carried out for: hepatocellular carcinoma (n = 6), colorectal metastases (n = 6), cholangiocarcinoma (n = 5), gastrointestinal stromal tumor (n = 2), hepatoblastoma (n = 2), and squamous cell carcinoma in 1 patient. Liver resections performed included 13 right trisegmentectomies, 6 right lobectomies extended to include the caudate lobe, and 3 left trisegmentectomies. Complex ex vivo procedures were performed in 2 cases using venovenous bypass while the other 20 cases were performed using varying degrees of vascular isolation. In situ cold perfusion of the liver was used in 1 case. The IVC was reconstructed with ringed Gore-Tex tube graft (n = 14), primarily (n = 6), or with Gore-Tex patches (n = 2). Results: There were 2 perioperative deaths (9%). One cirrhotic patient died of liver failure 3 weeks post operatively and 1 patient with cholangiocarcinoma died of pulmonary hemorrhage secondary to a cavitating pulmonary infection after aspiration pneumonia 6 weeks after resection. Six patients had evidence of postoperative liver failure that resolved with supportive management and 2 patients required temporary dialysis. All vascular reconstructions were patent at last follow-up. With median follow-up of 26 months, 5 patients have died of recurrent malignancy at 44, 40, 32, 26, and 24 months, while an additional patient is alive with disease at 31 months. Actuarial 1-, 3-, and 5-year survivals were 85%, 60%, and 33%, respectively. Conclusions: IVC involvement by hepatic malignancy does not necessarily preclude resection. Liver resection with reconstruction of the inferior vena cava can be performed in selected cases. The increased risk associated with the procedure appears to be balanced by the possible benefits, particularly when the lack of alternative curative approaches is considered. PMID:15082976

  3. Supra hepatic inferior vena cava and right atrial thrombosis following a traffic car crash.

    PubMed

    Sabzi, Feridoun; Karim, Hosein; Haghi, Marjan

    2016-07-01

    We present a case of nephrotic syndrome associated with right atrial and supra hepatic vein part of inferior vena caval thrombosis. This patient presented with dyspena, lower extremity edema and back pain after a vehicle accident and blunt trauma to the abdomen. Trauma should be considered not only as a thrombophilic pre-disposition, but also as a predisposing factor to IVC endothelium injury and thrombosis formation. Echocardiography revealed supra hepatic vein IVC thrombosis floating to the right atrium. A C-T scan with contrast also showed pulmonary artery emboli to the left upper lobe. With open heart surgery, the right atrial and IVC clot were extracted and the main left and right pulmonary arteries were evaluated for possible clot lodging. The patient had an uneventful postoperative recovery and thrombosis has not reoccurred with periodical follow-up examinations. © 2016 KUMS, All rights reserved.

  4. Cannulation for veno-venous extracorporeal membrane oxygenation

    PubMed Central

    2018-01-01

    Extracorporeal membrane oxygenation (ECMO) is described as a modified, smaller cardiopulmonary bypass circuit. The veno-venous (VV) ECMO circuit drains venous blood, oxygenate the blood, and pump the blood back into the same venous compartment. Draining and reinfusing in the same compartment means there are a risk of recirculation. The draining position within the venous system, ECMO pump flow, return flow position within the venous system and the patients cardiac output (CO) all have an impact on recirculation. Using two single lumen cannulas or one dual lumen cannula, but also the design of the venous cannula, can have an impact on where within the venous system the cannula is draining blood and will affect the efficiency of the ECMO circuit. VV ECMO can be performed with different cannulation strategies. The use of two single lumen cannulas draining in inferior vena cava (IVC) and reinfusing in superior vena cava (SVC) or draining in SVC and reinfusing in IVC, or one dual lumen cannula inserted in right jugular vein is all possible cannulation strategies. Independent of cannulation strategy there will be a risk of recirculation. Efficiency can be reasonable in either strategy if the cannulas are carefully positioned and monitored during the dynamic procedure of pulmonary disease. The disadvantage draining from IVC only occurs when there is a need for converting from VV to veno-arterial (VA) ECMO, reinfusing in the femoral artery. Then draining from SVC is the most efficient strategy, draining low saturated venous blood, and also means low risk of dual circulation. PMID:29732177

  5. Topographic anatomy of the fetal inferior vena cava, coronary sinus, and pulmonary veins: Variations in Chiari's network.

    PubMed

    Naito, Michiko; Yu, Hee Chul; Kim, Ji Hyun; Rodríguez-Vázquez, José Francisco; Murakami, Gen; Cho, Baik Hwan

    2015-07-01

    To understand anomalies in Chiari's network better, we assessed the topographical anatomy of the fetal inferior vena cava (IVC), coronary sinus, and atria. We examined sagittal serial paraffin sections of 15 human fetuses of crown-rump length 24-36 mm, corresponding to a gestational age of 8 weeks. Although their outflow tract morphologies were similar, these 15 specimens could be classified into two groups. In eight specimens, the left common cardinal vein reached the body wall, whereas in the other seven the vein was obliterated near the left pulmonary vein. Irrespective of the group in which the specimen was included, the anteroposterior arrangement of the coronary sinus, the sinus septum (septum), and the right sinus valve (right valve) could be classified into three types: the right valve-septum-coronary sinus arrangement in seven specimens; the right valve-coronary sinus-septum arrangement in five; and the coronary sinus-right valve-septum arrangement in three. Depending on differences in topographical anatomy, the sinus septum separated the coronary sinus opening from either the right or the left atrium. Likewise, the coronary sinus opening was either adjacent to or distant from the IVC terminal. Rather than the counter-side position of the right valve being at the IVC terminal, the left sinus valve protruded leftward, forming an incomplete interatrial septum. Fetal variations seemed to be closely connected with individual variations and a high frequency of Chiari's network anomalies in adults. © 2014 Wiley Periodicals, Inc.

  6. 48-hours administration of fenoterol in spontaneous preterm labor - does it affect fetal preload?

    PubMed

    Grzesiak, Mariusz; Forys, Sebastian; Sobczak, Malgorzata; Ahmed, Rehana B; Wilczynski, Jan

    2013-01-01

    to investigate whether any changes in the preload index (PLI) occur within the first 48 hours of fenoterol intravenous tocolysis. Doppler evaluation of placental and fetal circulation was performed in 36 pregnant women prior to fenoterol administration and after 24/48 hours. Measurements were obtained from a longitudinal section of the inferior vena cava (IVC) and preload index was calculated. To determine changes over time, an all study variable analysis of variance (ANOVA) for repeated measurements, followed by Tukey-Kramer's multiple comparison test was used. The effects of additional clinical covariates were checked. The maternal heart rate values were significantly increased after 24 hours and 48 hours in comparison to pre-treatment values. No significant changes in fetal heart rate were observed during treatment. The fetal IVC PLI values were significantly reduced after 24 hours and 48 hours of treatment. The increase in PLI values when comparing 24 and 48 hours results were not statistically significant. These observations were consistent with ANOVA post-hoc analysis. 48 hours intravenous administration of fenoterol appears not to alter inferior vena cava blood flow by itself. The reduction in PLI values may reflect lower fetal preload conditions during the course of successful tocolytic treatment. Therefore, Doppler IVC PLI measurement should be considered as a possible additional assessment method of effectiveness of treatment. However, other Doppler venous blood flow parameters should be assessed to confirm the results and clarify whether maternal corticosteroids administration may be interfering with the results.

  7. Effects of abdominal pressure on venous return: abdominal vascular zone conditions.

    PubMed

    Takata, M; Wise, R A; Robotham, J L

    1990-12-01

    The effects of changes in abdominal pressure (Pab) on inferior vena cava (IVC) venous return were analyzed using a model of the IVC circulation based on a concept of abdominal vascular zone conditions analogous to pulmonary vascular zone conditions. We hypothesized that an increase in Pab would increase IVC venous return when the IVC pressure at the level of the diaphragm (Pivc) exceeds the sum of Pab and the critical closing transmural pressure (Pc), i.e., zone 3 conditions, but reduce IVC venous return when Pivc is below the sum of Pab and Pc, i.e., zone 2 conditions. The validity of the model was tested in 12 canine experiments with an open-chest IVC bypass. An increase in Pab produced by phrenic stimulation increased the IVC venous return when Pivc-Pab was positive but decreased the IVC venous return when Pivc - Pab was negative. The value of Pivc - Pab that separated net increases from decreases in venous return was 1.00 +/- 0.72 (SE) mmHg (n = 6). An increase in Pivc did not influence the femoral venous pressure when Pivc was lower than the sum of Pab and a constant, 0.96 +/- 0.70 mmHg (n = 6), consistent with presence of a waterfall. These results agreed closely with the predictions of the model and its computer simulation. The abdominal venous compartment appears to function with changes in Pab either as a capacitor in zone 3 conditions or as a collapsible Starling resistor with little wall tone in zone 2 conditions.

  8. Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.

    PubMed

    Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John

    2015-06-01

    Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.

  9. Management of Noncompressible Hemorrhage Using Vena Cava Ultrasound

    DTIC Science & Technology

    2016-10-01

    with this study, Dr. Doucet has produced “Protocol Video USA-IVC Study (Version 5)” that is posted on youtube : https://youtu.be/54-Z6fiJpPY This video... youtube : https://youtu.be/54-Z6fiJpPY This video contains study design, procedures, inclusion/exclusion criteria and a demonstration to train clinical

  10. A marked proportional rise in IVC aldosterone following cosyntropin administration during AVS is a signal to the presence of adrenal hyperplasia in primary aldosteronism.

    PubMed

    Kline, G A; Pasieka, J L; Harvey, A; So, B; Dias, V C

    2014-05-01

    We hypothesized aldosteronoma responsiveness to cosyntropin may be a characterizing feature that could be determined in addition to standard adrenal vein sampling (AVS) data. We reviewed an AVS database from June 2005 to October 2011 including 65 patients with confirmed primary aldosteronism (PA) who underwent AVS and, if applicable, unilateral adrenalectomy. Patients were divided into confirmed lateralized and non-lateralized groups and subgrouped by histology. Plasma aldosterone in inferior vena cava (IVC) pre- and post-cosyntropin infusion during AVS was measured. Peak aldosterone and proportional change was compared between groups. Baseline and peak IVC aldosterone was higher in lateralized patients but incremental aldosterone rise was much greater in subjects with bilateral hyperplasia. From receiver operator characteristics (ROC) analysis, the optimized diagnostic cut point of peak IVC aldosterone of >649 pmol l(-1) would have a sensitivity of 94% for surgical disease although specificity of just 59%. A 250% increase in IVC aldosterone following cosyntropin would be specific enough to exclude 87% of surgical/lateralized disease. These diagnostic capabilities are similar to other results with non-AVS tests performed for diagnosis of lateralization. Although not specific enough to replace standard AVS interpretation, a marked IVC aldosterone increase after cosyntropin during AVS is a useful additional test to diagnose non-lateralizing forms of PA. Such a calculation requires no additional expense or tests.

  11. Mid- and long-term outcome of patients with permanent inferior vena cava filters: a single center review.

    PubMed

    Chow, Felix Che-Lok; Chan, Yiu-Che; Cheung, Grace Chung-Yan; Cheng, Stephen Wing-Keung

    2015-07-01

    Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE), especially in patients with active contraindication to systemic anticoagulation. The aim of this study is to examine the outcomes of patients who received permanent IVC filters at our institution. This is a single-center retrospective observational study with review of a prospectively collected database for patients who had permanent IVC filters. Patient demographics, indications of filter placement, postprocedure clinical outcome and complications, as well as use of anticoagulant therapy were documented. Chi-squared test was used to test for statistically significant differences (IBM SPSS version 21; IBM Corp., Armonk, NY), while survival was calculated using Kaplan-Meier survival curves analysis. Between February 1998 and December 2013, a total of 109 patients with a median age of 65 (47 men, range 19-97) years had IVC filters inserted at our institution. All of them had documented venous thromboembolism (VTE) before filter placement: 99 (90.8%) had lower extremity deep vein thrombosis (DVT) (including 34 iliac, 65 infrainguinal), 9 (8.3%) had massive PE without evidence of lower limb DVT, and 1 (0.9%) had isolated IVC thrombosis. Forty-seven (43.1%) patients had PE before filter insertion. There were 2 serious procedure-related complications: one access site thrombosis and one right ventricular perforation. With a mean follow-up of 36 ± 33 months, no patient had further symptomatic PE or paradoxical embolism. There were a total of 54 (49.5%) deaths, with a 30-day mortality of 8.3%; none of them was device or procedure related. Among the 92 patients followed up, 27 (29.3%) had further VTE-either DVT in the index or the contralateral lower limb (20 patients, 21.7%), or thrombus inside the filter or the IVC (14 patients, 15.2%). Forty-one (44.6%) patients reported post-thrombotic syndrome (PTS) symptoms. Anticoagulant therapy was given to 39 (42.4%) and 55 (59.8%) patients in the periprocedural period and at any time during the study period, respectively. It did not reduce the rate of postfilter VTE or PTS in both instances. None of the filters in this series was retrieved. This observational study showed that IVC filters were effective in the prevention of PE, although symptomatic postfilter VTE and PTS were common, leading to significant morbidity. Patients who received permanent filters have high mortality on follow-up; however, none were procedure or device related. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Physiologic Effect of Stent Therapy for Inferior Vena Cava Obstruction Due to Malignant Liver Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kishi, Kazushi; Sonomura, Tetsuo; Fujimoto, Hisashi

    Purpose. To understand systemic the influence of stent therapy for inferior vena cava (IVC) obstruction due to advanced liver tumor. Methods. Seven patients with symptomatic IVC obstruction due to advanced primary (n 4) or secondary (n = 3) liver tumor were subjected to stent therapy. Enrollment criteria included high IVC pressure over 15 mmHg and the presence of edema and ascites. Z-stents were deployed using coaxial sheath technique via femoral venous puncture. Physiologic and hematobiochemical parameters were analyzed. Results. All procedures were successful, and the stents remained patent until patient death. Promptly after stent placement, the IVC flow recovered, andmore » the venous blood pressure in the IVC below the obstruction level showed a significant decrease from 20.8 {+-} 1.2 mmHg (mean {+-} SE) to 10.7 {+-} 0.7 mmHg (p < 0.01). Transient mild increase of right atrial pressure was observed in 1 patient. During the following week prominent diuresis was observed in all patients. Mean urine output volume in the 3 days before the stent therapy was 0.81 {+-} 0.09 l/day compared with 2.1 {+-} 0.2 l/day (p < 0.01) in the 3 days after. The edema and ascites decreased in all patients. The caval pressure change correlated well (r > 0.6) with the urine volume increase, and with the decreased volume of edema and ascites. The urine volume increase correlated well with the decrement of edema, but not with that of ascites. Improvements for various durations in the levels of blood urea nitrogen, serum creatinine, lactate dehydrogenase, fibrinogen, and platelet count were found (p < 0.05). These hematobiochemical changes were well correlated with each other and with the decrement of ascites. Two patients showed a low blood sodium level of 128.5 mEq/l after intensive natriuresis, and one of them died on day 21 with hepatic failure, which was interpreted as maladaptation aggravation. The mean survival time was 94.1 {+-} 34.1 days (mean {+-} SD), ranging from 21 to 140 days after stent treatment. Conclusion. The stent therapy for IVC obstruction due to malignant liver tumors was followed by a series of physiologic and hematobiochemical consequences, most of them favorable but some possibly unfavorable. Rational interpretations and predictions of sequelae based on physiologic science including cardiology, hepatology, and nephrology would facilitate the best management of stent therapy for malignant IVC obstruction.« less

  13. Clinical Sequelae of Thrombus in an Inferior Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmad, Iftikhar; Yeddula, Kalpana; Wicky, Stephan

    The purpose of this study was to assess the long-term clinical sequelae of inferior vena cava (IVC) filter thrombus and the effect of anticoagulation on filter thrombus. Of 1,718 patients who had IVC filters placed during 2001-2008, 598 (34.8%) had follow-up abdominal CT. Filter thrombus was seen in 111 of the 598 (18.6%). There were 44 men (39.6%). The mean age at filter placement was 64 years. The medical diseases included cancer in 64, trauma in 15, stroke in 12, and others in 20. The frequency of filter thrombus on CT and asymptomatic filter thrombus on CT was calculated. Themore » frequency of pulmonary embolism (PE) in patients with filter thrombus was calculated. The frequency of thrombus progression or regression (on CT, available in 56) was calculated. The effect of anticoagulation on filter thrombus regression/progression was evaluated using the Fisher exact test by comparing the group of patients who received anticoagulants versus those who did not. A P-value of <0.05 was considered significant. The overall frequency of filter thrombus was 18.6%. Total occlusion of the IVC filter was seen in 12 of 598 (2%). The filter thrombus was asymptomatic in 110 (18.3%). Filter thrombus was detected after a median of 35 days (range, 0-2082) following filter placement. Thrombus extended above the filter in 4 (3.6%); IVC thrombus below the filter was seen in 35(31.5%). Thrombus in the filter occluded <25% of the filter volume in 58 (52.3%), 25-50% in 21 (18.9%), and 50-75% in 20 (18%). Total IVC occlusion was seen in 12 (10.8%). Eighty-three patients received anticoagulation. Sixteen patients developed symptoms of PE. PE was confirmed on CT in 3 of 15 (2.7%). On follow-up, filter thrombus regressed completely in 19 (33.9%) after a median of 6 months. Filter thrombus decreased in size in 13 (23.2%) and it progressed without IVC occlusion in 7 (12.6%). In one (1.7%), filter thrombus progressed to IVC occlusion. Filter thrombus remained stable in 16 (28.6%). There was no significant difference in thrombus regression or progression rates whether or not the patients received anticoagulation for filter thrombus. In conclusion, asymptomatic thrombus in the filter is common and it rarely progresses to complete caval occlusion. Anticoagulation has little effect on the resolution of filter thrombosis and future occurrence of PE.« less

  14. Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?

    PubMed

    Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette

    2018-03-01

    Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study shows that the filter appears to protect against PE in pregnancy but the numbers are small. Complications such as filter thrombosis and IVC penetration appear to be higher in pregnancy but this difference is not statistically significant. It is not possible to retrieve the device in one out of every four pregnant women. This has implications in terms of long term risk of lower limb thrombosis and post thrombotic syndrome. The decision to use an IVC filter in pregnancy needs careful consideration by a multidisciplinary team. The benefit and risk assessment should be individualised and clearly outlined to the patient. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Robotic inferior vena cava surgery.

    PubMed

    Davila, Victor J; Velazco, Cristine S; Stone, William M; Fowl, Richard J; Abdul-Muhsin, Haidar M; Castle, Erik P; Money, Samuel R

    2017-03-01

    Inferior vena cava (IVC) surgery is uncommon and has traditionally been performed through open surgical approaches. Renal cell carcinoma with IVC extension generally requires vena cavotomy and reconstruction. Open removal of malpositioned IVC filters (IVCF) is occasionally required after endovascular retrieval attempts have failed. As our experience with robotic surgery has advanced, we have applied this technology to surgery of the IVC. We reviewed our institution's experience with robotic surgical procedures involving the IVC to determine its safety and efficacy. All patients undergoing robotic surgery that included cavotomy and repair from 2011 to 2014 were retrospectively reviewed. Data were obtained detailing preoperative demographics, operative details, and postoperative morbidity and mortality. Ten patients (6 men) underwent robotic vena caval procedures at our institution. Seven patients underwent robotic nephrectomy with removal of IVC tumor thrombus and retroperitoneal lymph node dissection. Three patients underwent robotic explantation of an IVCF after multiple endovascular attempts at removal had failed. The patients with renal cell carcinoma were a mean age of was 65.4 years (range, 55-74 years). Six patients had right-sided malignancy. All patients had T3b lesions at time of diagnosis. Mean tumor length extension into the IVC was 5 cm (range, 1-8 cm). All patients underwent robotic radical nephrectomy, with caval tumor thrombus removal and retroperitoneal lymph node dissection. The average operative time for patients undergoing surgery for renal cell carcinoma was 273 minutes (range, 137-382 minutes). Average intraoperative blood loss was 428 mL (range, 150-1200 mL). The patients with IVCF removal were a mean age of 33 years (range, 24-41 years). Average time from IVCF placement until robotic removal was 35.5 months (range, 4.3-57.3 months). Before robotic IVCF removal, a minimum of two endovascular retrievals were attempted. Average operative time for patients undergoing IVCF removal was 163 minutes (range, 131-202 minutes). Intraoperative blood loss averaged 250 mL (range, 150-350 mL). All procedures were completed robotically. The mean length of stay for all patients was 3.5 days (range, 1-8 days). All patients resumed ambulation on postoperative day 1. Nine patients resumed a regular diet on postoperative day 2. One patient with a renal tumor sustained a colon injury during initial adhesiolysis, before robotic radical nephrectomy, which was recognized at the initial operation and repaired robotically. Robotic radical nephrectomy and caval tumor removal were then completed. No blood transfusions were required intraoperatively, but three patients required blood transfusions postoperatively. Although robotic IVC surgery is uncommon, our initial limited experience demonstrates it is safe and efficacious. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Endovascular Removal of Fractured Inferior Vena Cava Filter Fragments: 5-Year Registry Data with Prospective Outcomes on Retained Fragments.

    PubMed

    Kesselman, Andrew J; Hoang, Nam Sao; Sheu, Alexander Y; Kuo, William T

    2018-06-01

    To evaluate the safety and efficacy of attempted percutaneous filter fragment removal during retrieval of fractured inferior vena cava (IVC) filters and to report outcomes associated with retained filter fragments. Over a 5-year period, 82 consecutive patients presenting with a fractured IVC filter were prospectively enrolled into an institutional review board-approved registry. There were 27 men and 55 women (mean, 47 y; range, 19-85 y). After main filter removal, percutaneous removal of fragments was attempted if they were deemed intravascular and accessible on preprocedural computed tomography (CT), cone-beam CT, and/or intravascular ultrasound; distal pulmonary artery (PA) fragments were left alone. A total of 185 fragments were identified (81 IVC, 33 PA, 16 cardiac, 2 hepatic vein, 1 renal vein, 1 aorta, 51 retroperitoneal). Mean filter dwell time was 2,183 days (range, 59-9,936 d). Eighty-seven of 185 fragments (47%) were deemed amenable to attempted removal: 65 IVC, 11 PA, 8 cardiac, 2 hepatic, and 1 aortic. Primary safety outcomes were major procedure-related complications. Fragment removal was successful in 78 of 87 cases (89.7%; 95% confidence interval [CI], 81.3-95.2). There were 6 minor complications with no consequence (6.9%; 95% CI, 2.6-14.4) involving intraprocedural fragment embolization and 1 major complication (1.1%; 95% CI, 0.0-6.2), a cardiac tamponade that was successfully treated. The complication rate from attempted cardiac fragment removal was 12.5% (1 of 8; 95% CI, 0.3-52.7). Among patients with retained cardiopulmonary fragments (n = 19), 81% remained asymptomatic during long-term clinical follow-up of 845 days (range, 386-2,071 d). Percutaneous removal of filter fragments from the IVC and proximal PAs is safe and effective overall, but attempted intracardiac fragment removal carries a higher risk of complication. Most residual filter fragments not amenable to percutaneous removal remain asymptomatic and may be monitored clinically. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  17. Outcomes of endovascular reconstruction of the inferior vena cava with self-expanding nitinol stents.

    PubMed

    Sebastian, Tim; Dopheide, Jörn F; Engelberger, Rolf P; Spirk, David; Kucher, Nils

    2018-05-01

    Occlusion of the inferior vena cava (IVC) often causes venous claudication, leg swelling, or skin changes. We hypothesized that the outcome of nitinol stents for endovascular reconstruction of the IVC is similar to the outcome reported for steel alloy stents. From the prospective Bern Venous Stent Registry, we investigated technical success, patency rates, and clinical outcome in consecutive patients with endovascular IVC reconstruction. During routine follow-up visits, stent patency was assessed by duplex ultrasound. Clinical outcomes were evaluated using the Bozkaya score, Villalta score, and revised Venous Clinical Severity Score. Of the 62 patients (mean age, 46 ± 18 years), 33 (53%) patients were treated for the post-thrombotic syndrome, 17 (27%) for acute thrombosis, and 12 (19%) for nonthrombotic IVC occlusion. Technical success was achieved in 61 (98%) patients, with a mean of 4.5 ± 1.9 stents (iliac kissing stents in 84%). During follow-up (mean, 21 months), 22 (36%) underwent endovascular reintervention for symptomatic stent stenosis (13 [21%] with complete stent occlusion). Primary, primary assisted, and secondary patency rates at 24 months were 57% (95% confidence interval [CI], 50%-73%), 76% (95% CI, 65%-86%), and 87% (95% CI, 80%-95%), respectively. None developed new ulcers, and all eight patients with venous ulcers at baseline had complete healing. Twenty-nine (48%) patients showed significant clinical improvement, and another 26 (43%) were free from any symptoms or signs of venous hypertension. Patients with post-thrombotic venographic changes of the femoral veins at baseline or a history of thrombosis were more likely to lose primary patency compared with patients with normal leg inflow veins and no history of thrombosis (19 [48%] vs 3 [16%]; P = .02). The clinical outcome of endovascular reconstruction of the IVC with nitinol stents was favorable. However, approximately one-third of the patients required reintervention to maintain stent patency, most likely because of the impaired venous inflow. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Early ultrasonographic evaluation of tumor thrombus level during sunitinib therapy for renal cell carcinoma.

    PubMed

    Sano, Futoshi; Fusayasu, Syusei; Otake, Shinji; Yamanaka, Hiroyuki; Tatenuma, Tomoyuki; Sakata, Ryoko; Makiyama, Kazuhide; Nakaigawa, Noboru; Yao, Masahiro; Kubota, Yoshinobu

    2013-10-01

    A 72-year-old man presenting with a 14-cm left renal mass, an inferior vena cava (IVC) tumor thrombus, and pulmonary metastases underwent renal mass biopsy that revealed clear cell renal cell carcinoma. Because of metastases and the extent of the tumor thrombus, sunitinib was administered, which resulted in a marked reduction in the tumor thrombus (from level III to level II after 11 weeks of treatment). Ultrasonography, preceding computed tomography, showed a slight shrinkage of the tumor thrombus level in the first 2 weeks. Therefore, ultrasound may be advantageous to monitor the IVC tumor thrombus level during the early phase of targeted therapy.

  19. Chronic Pain Syndrome Caused by a Bird's Nest Filter: First Case Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Basheer, Mamoun Ahmad, E-mail: drbasheer30@yahoo.co; Hamilton, Mark; Holdaway, Chris

    2008-07-15

    AimTo report the first case of a Bird's Nest IVC filter causing a chronic pain syndrome lasting 13 years through IVC wall penetration and subsequent break off of one of the filter struts.Materials and ResultsA 43-year-old female presented with a 13-year history of abdominal pain following uneventful insertion of a Bird's Nest vena cava filter through a right internal jugular percutanous approach. A year following the procedure, CT scan revealed one arm of the filter to be outside IVC borders. Nine years from the date of insertion the nature of the pain changed acutely following a five feet jump tomore » more localized RUQ pain worse with twisting movements. A CT scan showed the strut to have pierced the IVC wall and penetrated the Unicate process of pancreas. Plain x-rays taken at different times in February 2006 showed one of the struts to be free floating in the peritoneal cavity. The floating strut was removed surgically from the wall of the Ileum. Postoperative recovery was uneventful and the patient was discharged pain free three days later.ConclusionChronic pain is an added complication of BNF devices. Although rare, it further emphasizes the need for long-term follow up of patients with IVC filters.« less

  20. The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kiefer, Ryan M., E-mail: rkiefer11@gmail.com; Pandey, Nirnimesh; Trerotola, Scott O.

    PurposeAccurately detecting inferior vena cava (IVC) filter complications is important for safe and successful retrieval as tip-embedded filters require removal with non-standard techniques. Venography prior to IVC filter retrieval has traditionally used a single anterior–posterior (AP) projection. This study compares the utility of rotational venography to AP venography prior to IVC filter removal.Materials and MethodsThe rotational venograms from 100 consecutive IVC filter retrievals over a 35-month period were evaluated retrospectively. The AP view of the rotational venogram was examined separately from the full series by a radiologist blinded to alternative imaging and operative findings. The venograms were evaluated for tipmore » embedding, filter fracture, filter thrombus, and IVC thrombus. Statistical analysis was performed.ResultsUsing operative findings and peri-procedural imaging as the reference standard, tip embedding occurred in 59 of the 100 filters (59 %). AP venography was used to correctly identify 31 tip-embedded filters (53 % sensitivity) with two false positives (95 % specificity) for an accuracy of 70 %. Rotational venography was used to correctly identify 58 tip-embedded filters (98 % sensitivity) with one false positive (98 % specificity) for an accuracy of 98 %. A significant difference was found in the sensitivities of the two diagnostic approaches (P < .01). Other findings of thrombus and filter fracture were not significantly different between the two groups.ConclusionRotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.« less

  1. Ultrasound assessment of severe dehydration in children with diarrhea and vomiting.

    PubMed

    Levine, Adam C; Shah, Sachita P; Umulisa, Irenee; Munyaneza, Richard B Mark; Dushimiyimana, Jean Marie; Stegmann, Katrina; Musavuli, Juvenal; Ngabitsinze, Protogene; Stulac, Sara; Epino, Henry M; Noble, Vicki E

    2010-10-01

    The objective of this study was to determine the test characteristics for two different ultrasound (US) measures of severe dehydration in children (aorta to inferior vena cava [IVC] ratio and IVC inspiratory collapse) and one clinical measure of severe dehydration (the World Health Organization [WHO] dehydration scale). The authors enrolled a prospective cohort of children presenting with diarrhea and/or vomiting to three rural Rwandan hospitals. Children were assessed clinically using the WHO scale and then underwent US of the IVC by a second clinician. All children were weighed on admission and then fluid-resuscitated according to standard hospital protocols. A percent weight change between admission and discharge of greater than 10% was considered the criterion standard for severe dehydration. Receiver operating characteristic (ROC) curves were created for each of the three tests of severe dehydration compared to the criterion standard. Children ranged in age from 1 month to 10 years; 29% of the children had severe dehydration according to the criterion standard. Of the three different measures of dehydration tested, only US assessment of the aorta/IVC ratio had an area under the ROC curve statistically different from the reference line. At its best cut-point, the aorta/IVC ratio had a sensitivity of 93% and specificity of 59%, compared with 93% and 35% for IVC inspiratory collapse and 73% and 43% for the WHO scale. Ultrasound of the aorta/IVC ratio can be used to identify severe dehydration in children presenting with acute diarrhea and may be helpful in guiding clinical management. © 2010 by the Society for Academic Emergency Medicine.

  2. Inferior Vena Cava Filters to Prevent Pulmonary Embolism: Systematic Review and Meta-Analysis.

    PubMed

    Bikdeli, Behnood; Chatterjee, Saurav; Desai, Nihar R; Kirtane, Ajay J; Desai, Mayur M; Bracken, Michael B; Spencer, Frederick A; Monreal, Manuel; Goldhaber, Samuel Z; Krumholz, Harlan M

    2017-09-26

    Inferior vena cava (IVC) filters are widely used for prevention of pulmonary embolism (PE). However, uncertainty persists about their efficacy and safety. The authors conducted a systematic review and meta-analysis of the published reports on the efficacy and safety of IVC filters. The authors searched PubMed, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov through October 3, 2016, for randomized controlled trials (RCTs) or prospective controlled observational studies of IVC filters versus none in patients at risk of PE. Inverse variance fixed-effects models with odds ratio (OR) as the effect measure were used for primary analyses. Main outcomes included subsequent PE, PE-related mortality, all-cause mortality, and subsequent deep vein thrombosis (DVT). The authors' search retrieved 1,986 studies, of which 11 met criteria for inclusion (6 RCTs and 5 prospective observational studies). Quality of evidence for RCTs was low to moderate. Overall, patients receiving IVC filters had lower risk for subsequent PE (OR: 0.50; 95% confidence interval [CI]: 0.33 to 0.75); increased risk for DVT (OR: 1.70; 95% CI: 1.17 to 2.48); nonsignificantly lower PE-related mortality (OR: 0.51; 95% CI: 0.25 to 1.05); and no change in all-cause mortality (OR: 0.91; 95% CI: 0.70 to 1.19). Limiting the results to RCTs showed similar results. Findings were substantively similar across a wide range of sensitivity analyses. Very few prospective controlled studies, with limited quality of evidence, exist regarding the efficacy and safety of IVC filters. Overall, filters appear to reduce the risk of subsequent PE, increase the risk for DVT, and have no significant effect on overall mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Efficacy of Lower-Extremity Venous Thrombolysis in the Setting of Congenital Absence or Atresia of the Inferior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ganguli, Suvranu, E-mail: sganguli@partners.org; Kalva, Sanjeeva; Oklu, Rahmi

    Purpose: A rare but described risk factor for deep venous thrombosis (DVT), predominately in the young, is congenital agenesis or atresia of the inferior vena cava (IVC). The optimal management for DVT in this subset of patients is unknown. We evaluated the efficacy of pharmacomechanical catheter-directed thrombolysis (PCDT) followed by systemic anticoagulation in the treatment of acute lower-extremity DVT in the setting of congenital IVC agenesis or atresia. Materials and Methods: Between November of 2005 and May of 2010, six patients (three women [average age 21 years]) were referred to our department with acute lower-extremity DVT and subsequently found tomore » have IVC agenesis or atresia on magnetic resonance imaging. A standardized technique for PCDT (the Angiojet Rheolytic Thrombectomy System followed by the EKOS Microsonic Accelerated Thrombolysis System) was used for all subjects. Successful thrombolysis was followed by systemic heparinization with transition to Coumadin or low molecular-weight heparin and compression stockings. Subjects were followed-up at 1, 3, and then every 6 months after the procedure with clinical assessment and bilateral lower-extremity venous ultrasound. Results: All PCDT procedures were technically successful. No venous stenting or angioplasty was performed. The average thrombolysis time was 28.6 h (range 12-72). Two patients experienced heparin-induced thrombocytopenia, and one patient developed a self-limited knee hemarthrosis, No patients were lost to follow-up. The average length of follow-up was 25.8 {+-} 20.2 months (range 3.8-54.8). No incidence of recurrent DVT was identified. There were no manifestations of postthrombotic syndrome. Conclusions: PCDT followed by systemic anticoagulation and the use of compression stockings appears to be safe and effective in relatively long-term follow-up treatment of patients who present with acute DVT and IVC agenesis or atresia.« less

  4. Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans.

    PubMed

    Neuzil, Petr; Reddy, Vivek Y; Merkely, Bela; Geller, Laszlo; Molnar, Levente; Bednarek, Jacek; Bartus, Krzysztof; Richey, Mark; Bsee, T J Ransbury; Sanders, William E

    2014-02-01

    A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). The intravascular defibrillator has DFTs similar to those of commercially available ICDs. Published by Heart Rhythm Society on behalf of Heart Rhythm Society.

  5. Transcatheter Arterial Chemoembolization for Advanced Hepatocellular Carcinoma with Inferior Vena Cava and Right Atrial Tumors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chern, M. C., E-mail: mcchern@yahoo.com; Chuang, V. P., E-mail: vpc@mail.kfcc.org.tw; Cheng, T., E-mail: ticheng@mail.kfcc.org.tw

    Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groupsmore » based on their size: (A) >180 {mu}m, N = 9; and (B) 47-180 {mu}m, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/9 patients) for group A and 76.5% for group B (13/17 patients) (p < 0.02). No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 {mu}m) are superior to large ones (>180 {mu}m).« less

  6. A comparative CFD study of four inferior vena cava filters.

    PubMed

    López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc

    2018-03-30

    Computational fluid dynamics was used to simulate the flow of blood within an inferior vena cava (IVC) geometry model that was reconstructed from computed tomography images obtained from a real patient. The main novelty of the present work is that we simulated the implantation of 4 different filter models in this realistic IVC geometry. We considered different blood flow rates in the range between V in =20 and V in =80 cm 3 /s, and all simulations were performed with both the Newtonian and a non-Newtonian model for the blood viscosity. We compared the hemodynamics performance of the different filter models, and we paid a special attention to the total drag force, F d , exerted by the blood flow on the filter surface. This force is the sum of 2 contributions: the viscous skin friction force, which was found to be roughly proportional to the filter surface area, and the pressure force, which depended on the particular filter geometry design. The F d force is relevant because it must be balanced by the total force exerted by the filter hooks/struts on the IVC wall at the attachment locations. For the highest V in value investigated, the variation in F d among filters was from 116 to 308 dyne. We also showed how the present results can be extrapolated to obtain good estimates of the drag forces if the blood viscosity levels change, ie, if the patient with a filter implanted is treated with anticoagulant therapy. Copyright © 2018 John Wiley & Sons, Ltd.

  7. Transcatheter arterial chemoembolization for advanced hepatocellular carcinoma with inferior vena cava and right atrial tumors.

    PubMed

    Chern, M C; Chuang, V P; Cheng, T; Lin, Z H; Lin, Y M

    2008-01-01

    Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groups based on their size: (A) >180 microm, N = 9; and (B) 47-180 microm, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/8 [corrected] patients) for group A and 72.2% [corrected] for group B (13/18 [corrected] patients) (p < 0.01). [corrected] No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 microm) are superior to large ones (>180 microm).

  8. Analysis of the Final DENALI Trial Data: A Prospective, Multicenter Study of the Denali Inferior Vena Cava Filter.

    PubMed

    Stavropoulos, S William; Chen, James X; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Abdel Aal, Ahmed Kamel; Lansky, Alexandra; Muhs, Bart E

    2016-10-01

    To report the final 2-year data on the efficacy and safety of a nitinol retrievable inferior vena cava (IVC) filter for protection against pulmonary embolism (PE). This was a prospective multicenter trial of 200 patients with temporary indications for caval filtration who underwent implantation of the Denali IVC filter. After filter placement, all patients were followed for 2 years after placement or 30 days after filter retrieval. The primary endpoints were technical success of filter implantation in the intended location and clinical success of filter placement and retrieval. Secondary endpoints were incidence of clinically symptomatic recurrent PE, new or propagating deep vein thrombosis (DVT), and filter-related complications including migration, fracture, penetration, and tilt. Filter placement was technically successful in 199 patients (99.5%). Filters were clinically successful in 190 patients (95%). The rate of PE was 3% (n = 6), with 5 patients having a small subsegmental PE and 1 having a lobar PE. New or worsening DVT was noted in 26 patients (13%). Filter retrieval was attempted 125 times in 124 patients and was technically successful in 121 patients (97.6%). The mean filter dwell time at retrieval was 200.8 days (range, 5-736 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of filter retrieval or during follow-up. The Denali IVC filter exhibited high success rates for filter placement and retrieval while maintaining a low complication rate in this clinical trial. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  9. Novel and Advanced Techniques for Complex IVC Filter Retrieval.

    PubMed

    Daye, Dania; Walker, T Gregory

    2017-04-01

    Inferior vena cava (IVC) filter placement is indicated for the treatment of venous thromboembolism (VTE) in patients with a contraindication to or a failure of anticoagulation. With the advent of retrievable IVC filters and their ease of placement, an increasing number of such filters are being inserted for prophylaxis in patients at high risk for VTE. Available data show that only a small number of these filters are retrieved within the recommended period, if at all, prompting the FDA to issue a statement on the need for their timely removal. With prolonged dwell times, advanced techniques may be needed for filter retrieval in up to 60% of the cases. In this article, we review standard and advanced IVC filter retrieval techniques including single-access, dual-access, and dissection techniques. Complicated filter retrievals carry a non-negligible risk for complications such as filter fragmentation and resultant embolization of filter components, venous pseudoaneurysms or stenoses, and breach of the integrity of the caval wall. Careful pre-retrieval assessment of IVC filter position, any significant degree of filter tilting or of hook, and/or strut epithelialization and caval wall penetration by filter components should be considered using dedicated cross-sectional imaging for procedural planning. In complex cases, the risk for retrieval complications should be carefully weighed against the risks of leaving the filter permanently indwelling. The decision to remove an embedded IVC filter using advanced techniques should be individualized to each patient and made with caution, based on the patient's age and existing comorbidities.

  10. Quantification of hepatic flow distribution using particle tracking for patient specific virtual Fontan surgery

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Vignon-Clementel, Irene; Troianowski, Guillaume; Shadden, Shawn; Mohhan Reddy, V.; Feinstein, Jeffrey; Marsden, Alison

    2010-11-01

    The Fontan surgery is the third and final stage in a palliative series to treat children with single ventricle heart defects. In the extracardiac Fontan procedure, the inferior vena cava (IVC) is connected to the pulmonary arteries via a tube-shaped Gore-tex graft. Clinical observations have shown that the absence of a hepatic factor, carried in the IVC flow, can cause pulmonary arteriovenous malformations. Although it is clear that hepatic flow distribution is an important determinant of Fontan performance, few studies have quantified its relation to Fontan design. In this study, we virtually implanted three types of grafts (T-junction, offset and Y-graft) into 5 patient specific models of the Glenn (stage 2) anatomy. We then performed 3D time-dependent simulations and systematically compared the IVC flow distribution, energy loss, and pressure levels in different surgical designs. A robustness test is performed to evaluate the sensitivity of hepatic distribution to pulmonary flow split. Results show that the Y-graft design effectively improves the IVC flow distribution, compared to traditional designs and that surgical designs could be customized on a patient-by-patient basis.

  11. The Need for Anticoagulation Following Inferior Vena Cava Filter Placement: Systematic Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, Charles E.; Prochazka, Allan

    Purpose. To perform a systemic review to determine the effect of anticoagulation on the rates of venous thromboembolism (pulmonary embolus, deep venous thrombosis, inferior vena cava (IVC) filter thrombosis) following placement of an IVC filter. Methods. A comprehensive computerized literature search was performed to identify relevant articles. Data were abstracted by two reviewers. Studies were included if it could be determined whether or not subjects received anticoagulation following filter placement, and if follow-up data were presented. A meta-analysis of patients from all included studies was performed. A total of 14 articles were included in the final analysis, but the datamore » from only nine articles could be used in the meta-analysis; five studies were excluded because they did not present raw data which could be analyzed in the meta-analysis. A total of 1,369 subjects were included in the final meta-analysis. Results. The summary odds ratio for the effect of anticoagulation on venous thromboembolism rates following filter deployment was 0.639 (95% CI 0.351 to 1.159, p = 0.141). There was significant heterogeneity in the results from different studies [Q statistic of 15.95 (p = 0.043)]. Following the meta-analysis, there was a trend toward decreased venous thromboembolism rates in patients with post-filter anticoagulation (12.3% vs. 15.8%), but the result failed to reach statistical significance. Conclusion. Inferior vena cava filters can be placed in patients who cannot receive concomitant anticoagulation without placing them at significantly higher risk of development of venous thromboembolism.« less

  12. Advanced Technologies in Trauma Critical Care Management

    DTIC Science & Technology

    2012-01-01

    CVL, central venous line; DVT, deep venous thrombosis; FAST, focused assessment with sonography for trauma; IVC, inferior vena cava; PIV, peripheral...either for a 1-time view of the target vein or in real time using a 1- or 2-person technique. Recently, ultrasound-guided subclavian central venous ...technologies such as bedside echocardiography, central venous pressure monitoring, and cardiac electrical velocimetry. These limitations aside, it is

  13. The assessment of circulating volume using inferior vena cava collapse index and carotid Doppler velocity time integral in healthy volunteers: a pilot study.

    PubMed

    Peachey, Tom; Tang, Andrew; Baker, Elinor C; Pott, Jason; Freund, Yonathan; Harris, Tim

    2016-09-02

    Assessment of circulating volume and the requirement for fluid replacement are fundamental to resuscitation but remain largely empirical. Passive leg raise (PLR) may determine fluid responders while avoiding potential fluid overload. We hypothesised that inferior vena cava collapse index (IVCCI) and carotid artery blood flow would change predictably in response to PLR, potentially providing a non-invasive tool to assess circulating volume and identifying fluid responsive patients. We conducted a prospective proof of concept pilot study on fasted healthy volunteers. One operator measured IVC diameter during quiet respiration and sniff, and carotid artery flow. Stroke volume (SV) was also measured using suprasternal Doppler. Our primary endpoint was change in IVCCI after PLR. We also studied changes in IVCCI after "sniff", and correlation between carotid artery flow and SV. Passive leg raise was associated with significant reduction in the mean inferior vena cava collapsibility index from 0.24 to 0.17 (p < 0.01). Mean stroke volume increased from 56.0 to 69.2 mL (p < 0.01). There was no significant change in common carotid artery blood flow. Changes in physiology consequent upon passive leg raise normalised rapidly. Passive leg raise is associated with a decrease of IVCCI and increase in stroke volume. However, the wide range of values observed suggests that factors other than circulating volume predominate in determining the proportion of collapse with respiration. In contrast to other studies, we did not find that carotid blood flow increased with passive leg raise. Rapid normalisation of post-PLR physiology may account for this.

  14. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    PubMed

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Respiratory-Induced Haemodynamic Changes: A Contributing Factor to IVC Filter Penetration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laborda, Alicia, E-mail: alaborda@unizar.es; Kuo, William T., E-mail: wkuo@stanford.edu; Ioakeim, Ignatios, E-mail: ignacio.ioakim@hotmail.es

    2015-10-15

    PurposeThe purpose of the study is to evaluate the influence of respiratory-induced vena caval hemodynamic changes on filter migration/penetration.Materials and MethodsAfter placement of either a Gunther Tulip or Celect IVC filter, 101 consecutive patients scheduled for filter retrieval were prospectively enrolled in this study. Pre-retrieval CT scans were used to assess filter complications and to calculate cross-sectional area in three locations: at level of filter strut fixation, 3 cm above and 3 cm below. A 3D finite element simulation was constructed on these data and direct IVC pressure was recorded during filter retrieval. Cross-sectional areas and pressures of the vena cava weremore » measured during neutral breathing and in Valsalva maneuver and identified filter complications were recorded. A statistical analysis of these variables was then performed.ResultsDuring Valsalva maneuvers, a 60 % decrease of the IVC cross-sectional area and a fivefold increase in the IVC pressure were identified (p < 0.001). There was a statistically significant difference in the reduction of the cross-sectional area at the filter strut level (p < 0.001) in patient with filter penetration. Difficulty in filter retrieval was higher in penetrated or tilted filters (p < 0.001; p = 0.005). 3D computational models showed significant IVC deformation around the filter during Valsalva maneuver.ConclusionCaval morphology and hemodynamics are clearly affected by Valsalva maneuvers. A physiological reduction of IVC cross-sectional area is associated with higher risk of filter penetration, despite short dwell times. Physiologic data should be used to improve future filter designs to remain safely implanted over longer dwell times.« less

  16. A Multi-institutional Comparison of Adrenal Venous Sampling in Patients with Primary Aldosteronism: Caution Advised if Successful Bilateral Adrenal Vein Sampling is Not Achieved.

    PubMed

    Wang, Tracy S; Kline, Greg; Yen, Tina W; Yin, Ziyan; Liu, Ying; Rilling, William; So, Benny; Findling, James W; Evans, Douglas B; Pasieka, Janice L

    2018-02-01

    In patients with primary aldosteronism (PA), adrenal venous sampling (AVS) is recommended to differentiate between unilateral (UNI) or bilateral (BIL) adrenal disease. A recent study suggested that lateralization could be predicted, based on the ratio of aldosterone/cortisol levels (A/C) between the left adrenal vein (LAV) and inferior vena cava (IVC), with a 100% positive predictive value (PPV). This study aimed to validate those findings utilizing a larger, multi-institutional cohort. A retrospective review was performed of patients with PA who underwent AVS from 2 tertiary-care institutions. Laterality was predicted by an A/C ratio of >3:1 between the dominant and non-dominant adrenal. AVS results were compared to LAV/IVC ratios utilizing the published criteria (Lt ≥ 5.5; Rt ≤ 0.5). Of 222 patients, 124 (57%) had UNI and 98 (43%) had BIL disease based on AVS. AVS and LAV/IVC findings were concordant for laterality in 141 (64%) patients (69 UNI, 72 BIL). Using only the LAV/IVC ratio, 54 (24%) patients with UNI disease on AVS who underwent successful surgery would have been assumed to have BAH unless AVS was repeated, and 24 (11%) patients with BIL disease on AVS may have been incorrectly offered surgery (PPV 70%). Based on median LAV/IVC ratios (left 5.26; right 0.31; BIL 2.84), no LAV/IVC ratio accurately predicted laterality. This multi-institutional study of patients with both UNI and BIL PA failed to validate the previously reported PPV of LAV/IVC ratio for lateralization. Caution should be used in interpreting incomplete AVS data to differentiate between UNI versus BIL disease and strong consideration given to repeat AVS prior to adrenalectomy.

  17. Outcomes and Direct Costs of Inferior Vena Cava Filter Placement and Retrieval within the IR and Surgical Settings.

    PubMed

    Makary, Mina S; Kapke, Jordan; Yildiz, Vedat; Pan, Xueliang; Dowell, Joshua D

    2018-02-01

    To compare the outcomes and costs of inferior vena cava (IVC) filter placement and retrieval in the interventional radiology (IR) and surgical departments at a tertiary-care center. Retrospective review was performed of 142 sequential outpatient IVC filter placements and 244 retrievals performed in the IR suite and operating room (OR) from 2013 to 2016. Patient demographic data, procedural characteristics, outcomes, and direct costs were compared between cohorts. Technical success rates of 100% were achieved for both IR and OR filter placements, and 98% of filters were successfully retrieved by IR means, compared with 83% in the OR (P < .01). Fluoroscopy time was similar for IR and OR filter insertions, but IR retrievals required half the fluoroscopy time, with an average of 9 minutes vs 18 minutes in the OR (P = .02). There was no significant difference between cohorts in the incidences of complications for filter retrievals, but more postprocedural complications were observed for OR placements (8%) vs IR placements (1%; P = .05). The most severe complication occurred during an OR filter retrieval, resulting in entanglement of the snare device and conversion to an emergent open filter removal by vascular surgery. Direct costs were approximately 20% higher for OR vs IR IVC filter placements ($2,246 vs $2,671; P = .01). Filter placements are equally successfully performed in IR and OR settings, but OR patients experienced significantly higher postprocedural complication rates and incurred higher costs. In contrast, higher technical success rates and shorter fluoroscopy times were observed for IR filter retrievals compared with those performed in the OR. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  18. Management of inferior vena cava aneurysm.

    PubMed

    Montero-Baker, M F; Branco, B C; Leon, L L; Labropoulos, N; Echeverria, A; Mills, J L

    2015-10-01

    Inferior vena cava (IVC) aneurysm is an infrequent but potentially lethal abnormality. We have seen one such case in our group practice. We have added this case to a review of 53 previously reported cases in order to develop a management algorithm for this entity. We conducted a MedLine search of all English-language articles from the first reported case in 1950 through August 2013. Patient demographics, clinical data, management and outcomes were extracted. IVC aneurysms were categorized in 4 types as per Gradman and Steinberg classification. The mean patient age was 27.1 years (range 5-89) and 57.4% were male. A total of 11 (20.3%) had associated vascular anomalies and iliocaval thrombosis was found in 10 (18.5%). There were 23 type I aneurysms, 8 type IIs, 21 type IIIs and 2 type IVs. All but 1 type I was successfully managed conservatively without complications. For type IIs, only 3 patients were managed conservatively with 1 death related to stroke from paradoxical embolus. For type IIIs, resection was the most common management option (14 patients). One patient was treated endovascularly with aneurysm embolization. A total of 6 asymptomatic patients were treated conservatively with 1 death due to thromboembolism. For type IVs, all cases underwent expectant management with 1 death due to aneurysm rupture. IVC aneurysms are rare with only 54 cases reported in the literature. Associated vascular anomalies and iliocaval thrombosis should be expected in approximately 20% of cases. Type I aneurysms can be managed expectantly with close surveillance unless symptomatic. For type II-IV, surgical consideration should be given based on high rates of thromboembolic complications and non-negligible risk of rupture.

  19. The DENALI Trial: an interim analysis of a prospective, multicenter study of the Denali retrievable inferior vena cava filter.

    PubMed

    Stavropoulos, S William; Sing, Ronald F; Elmasri, Fakhir; Silver, Mitchell J; Powell, Alex; Lynch, Frank C; Aal, Ahmed Kamel Abdel; Lansky, Alexandra J; Settlage, Richard A; Muhs, Bart E

    2014-10-01

    To assess safety and effectiveness of a nitinol retrievable inferior vena cava (IVC) filter in patients who require caval interruption to protect against pulmonary embolism (PE). Two hundred patients with temporary indications for an IVC filter were enrolled in this prospective, multicenter clinical study. Patients undergoing filter implantation were to be followed for 2 years or for 30 days after filter retrieval. At the time of the present interim report, all 200 patients had been enrolled in the study, and 160 had undergone a retrieval attempt or been followed to 6 months with their filter in place. Primary study endpoints included technical and clinical success of filter placement and retrieval. Patients were also evaluated for recurrent PE, new or worsening deep vein thrombosis, and filter migration, fracture, penetration, and tilt. Clinical success of placement was achieved in 94.5% of patients (172 of 182), with a one-sided lower limit of the 95% confidence interval of 90.1%. Technical success rate of filter placement was 99.5%. Technical success rate of retrieval was 97.3%; 108 filters were retrieved in 111 attempts. In two cases, the filter apex could not be engaged with a snare, and one device was engaged but could not be removed. Filter retrievals occurred at a mean indwell time of 165 days (range, 5-632 d). There were no instances of filter fracture, migration, or tilt greater than 15° at the time of retrieval or 6-month follow-up. In this interim report, the nitinol retrievable IVC filter provided protection against pulmonary embolism, and the device could be retrieved with a low rate of complications. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  20. Impact of Anticoagulation in Elderly Patients With Pulmonary Embolism That Undergo IVC Filter Placement: A Retrospective Cohort Study.

    PubMed

    Falatko, John M; Dalal, Bhavinkumar; Qu, Lihua

    2017-12-01

    Anticoagulation is the primary treatment for pulmonary embolism (PE). Inferior vena cava (IVC) filters are an adjunctive intervention to prevent recurrent pulmonary embolism. Long-term outcomes in elderly patients with contraindications to anticoagulation after IVC filter placement for prevention of recurrent pulmonary embolism have yet to be assessed. Patients ≥60years of age, that had an IVC filter placed between 1 January, 2008 and 2 February, 2013, with a primary diagnosis of pulmonary embolism, were included. Patients that died during index hospitalisation, were discharged to hospice, or had active malignancy were excluded. The primary endpoint was overall survival. Patients were divided depending on whether they were treated with an approved anticoagulant for VTE or had no anticoagulant. Of the 152 patients identified, 55 were not anti-coagulated after IVC filter placement. The incidence of death was 0.4 per 1000 filter days and 0.7 per 1000 filter days in the anti-coagulated and untreated groups respectively (p-value=0.06). After statistical correction for co-morbid conditions, the effect of anticoagulation was not significant (HR 0.82 CI 0.49-1.37, p-value 0.46). Age was a significant confounder that was associated with death. Increased BMI was protective. Indications for IVC filter placement were numerous, but similar between the two groups. Treatment with an approved anticoagulant is recommended after IVC filter placement for prevention of recurrent PE, however its effect may be attenuated by advanced age. In elderly patients that have undergone IVC filter placement for prevention of recurrent PE, survival may be more dependent on age and co-morbid conditions than exposure to anticoagulation. Copyright © 2017 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Automated implantable cardioverter defibrillator lead infection in a patient with previous superior vena cava thrombosis.

    PubMed

    Connelly, Tara; Siddiqui, Sadiq; Kolcow, Walenty; Veerasingam, Dave

    2015-11-04

    We present a case of a 44-year-old woman who presented with cough, pleuritic chest pain and fever leading to a diagnosis of pneumonia±pulmonary embolism. She had a history of familial hypertrophic obstructive cardiomyopathy (HOCM), for which an automated implantable cardioverter defibrillator (AICD) had been implanted, and a subsequent superior vena cava (SVC) thrombus, for which she was anticoagulated with warfarin. On admission, blood cultures grew a coagulase-negative Staphylococcus. CT pulmonary angiogram and transoesophageal echocardiography (TOE) were performed and revealed large vegetations adherent to the AICD leads with complete occlusion of the SVC. The infected leads were the source of sepsis. Open surgery was planned. For cardiopulmonary bypass, the venous cannula was inserted in the inferior vena cava (IVC) and a completely bloodless field was obtained in the right atrium allowing for the extraction of the AICD leads completely, along with the adherent vegetations from within. 2015 BMJ Publishing Group Ltd.

  2. Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika

    The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%)more » had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).« less

  3. Retrievable Inferior Vena Cava Filters: Indications, Indwelling Time, Removal, Success and Complication Rates.

    PubMed

    Tashbayev, Alisher; Belenky, Alexander; Litvin, Sergey; Knizhnik, Michael; Bachar, Gil N; Atar, Eli

    2016-02-01

    Various vena cava filters (VCF) are designed with the ability to be retrieved percutaneously. Yet, despite this option most of them remain in the inferior vena cava (IVC). To report our experience in the placement and retrieval of three different types of VCFs, and to compare the indications for their insertion and retrieval as reported in the literature. During a 5 year period three types of retrievable VCF (ALN, OptEase, and Celect) were inserted in 306 patients at the Rabin Medical Center (Beilinson and Hasharon hospitals). Indications, retrieval rates, median time to retrieval, success and complication rates were viewed and assessed in the three groups of filter types and were compared with the data of similar studies in the literature. Of the 306 VCFs inserted, 31 (10.1%) were retrieved with equal distribution in the three groups. In most patients the reason for filter insertion was venous thromboembolic events (VTE) and contraindications to anticoagulant therapy. Mean age was 68.38 ± 17.5 years (range 18-99) and was noted to be significantly higher compared to similar studies (53-56 years) (P < 0.0001). Multi-trauma patients were significantly older (71.11 ± 14.99 years) than post-pulmonary embolism patients (48.03 ± 20.98 years, P < 0.0001) and patients with preventive indication (26.00 ± 11.31, P < 0.0001). The mean indwelling time was 100.6 ± 103.399 days. Our results are comparable with the results of other studies, and there was no difference in percentage of retrieval or complications between patients in each of the three groups. In 1 of 10 patients filters should be removed after an average of 3.5 months. All three IVC filter types used are safe to insert and retrieve.

  4. Control of respiration-driven retrograde flow in the subdiaphragmatic venous return of the Fontan circulation

    PubMed Central

    Vukicevic, M; Conover, T; Jaeggli, M; Zhou, J; Pennati, G; Hsia, TY; Figliola, RS

    2014-01-01

    Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only while the valve leaflets were closed while cycle-averaged pressures improved only slightly (italic>1 mm Hg). Increased pulmonary vascular resistance raised mean circulation pressures but the valve functioned and cardiac output improved and stabilized. Power loss across the TCPC improved by 12–15% (pbold>0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance. PMID:24814833

  5. Fontan completion in patients with atrial isomerism and separate hepatic venous drainage.

    PubMed

    Nakata, Tomohiro; Fujimoto, Yoshifumi; Hirose, Keiichi; Osaki, Masaki; Tosaka, Yuko; Ide, Yujiro; Tachi, Maiko; Sakamoto, Kisaburo

    2010-06-01

    Fontan completion in patients with atrial isomerism, in which the inferior vena cava (IVC) and the hepatic vein (HV) drain separately, is technically challenging. Herein, we review our surgical approach to these patients. The medical records of 50 consecutive patients with atrial isomerism who underwent Fontan completion between 1998 and 2008 were reviewed retrospectively. Separate HV drainage was present in 17 patients. Patients with interrupted IVC were excluded. Patient characteristics were as follows: median age, 26 months (range 15-149); median weight, 9.6 kg (range 8.1-47.2); right atrial isomerism, 16 patients; and left atrial isomerism, one. The IVC and the separate HV at the level of diaphragm were contralateral in 16 patients, and ipsilateral in one. The surgical procedures for directing blood flow from the IVC and the separate HV to the pulmonary arteries were as follows: en bloc resection of the IVC and the HV and anastomosing these veins to an extracardiac conduit in 10 patients; connecting the IVC to the HV in a side-to-side fashion before anastomosing them to an extracardiac conduit in one; and lateral tunnel in another. When the IVC and the HV were widely separated by the vertebrae, we chose an intra-extracardiac conduit (intra-atrial septation) in four patients and an extracardiac conduit for the IVC and the right HV and lateral tunnel for the separate left HV in one. There was no mortality. Five re-operations were performed (pacemaker in two patients; one each of fenestration, release of outflow obstruction and ligation of collateral arteries). Sixteen patients underwent follow-up catheterisation, which revealed central venous pressure of 12.0 + or - 2.0 mmHg and arterial oxygen saturation of 92% + or - 6%. The mid-term results of the Fontan completion in patients with atrial isomerism and separate HV drainage were excellent. The distance between the IVC and the separate HV and the position of the vertebrae should be considered when choosing a surgical technique. Copyright 2010. Published by Elsevier B.V.

  6. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings.

    PubMed

    Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Chowa, Erika P; Dvor, Nathan; Dworkis, Daniel A; Oh, Michael; Silvestri, David M; Strasberg, Stephen; Rege, Soham; Noble, Vicki E; Alam, Nur H; Levine, Adam C

    2016-01-01

    Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having "some dehydration" with weight change 3-9% or "severe dehydration" with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting.

  7. Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings

    PubMed Central

    Modi, Payal; Glavis-Bloom, Justin; Nasrin, Sabiha; Guy, Allysia; Rege, Soham; Noble, Vicki E.; Alam, Nur H.; Levine, Adam C.

    2016-01-01

    Introduction Although dehydration from diarrhea is a leading cause of morbidity and mortality in children under five, existing methods of assessing dehydration status in children have limited accuracy. Objective To assess the accuracy of point-of-care ultrasound measurement of the aorta-to-IVC ratio as a predictor of dehydration in children. Methods A prospective cohort study of children under five years with acute diarrhea was conducted in the rehydration unit of the International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b). Ultrasound measurements of aorta-to-IVC ratio and dehydrated weight were obtained on patient arrival. Percent weight change was monitored during rehydration to classify children as having “some dehydration” with weight change 3–9% or “severe dehydration” with weight change > 9%. Logistic regression analysis and Receiver-Operator Characteristic (ROC) curves were used to evaluate the accuracy of aorta-to-IVC ratio as a predictor of dehydration severity. Results 850 children were enrolled, of which 771 were included in the final analysis. Aorta to IVC ratio was a significant predictor of the percent dehydration in children with acute diarrhea, with each 1-point increase in the aorta to IVC ratio predicting a 1.1% increase in the percent dehydration of the child. However, the area under the ROC curve (0.60), sensitivity (67%), and specificity (49%), for predicting severe dehydration were all poor. Conclusions Point-of-care ultrasound of the aorta-to-IVC ratio was statistically associated with volume status, but was not accurate enough to be used as an independent screening tool for dehydration in children under five years presenting with acute diarrhea in a resource-limited setting. PMID:26766306

  8. The Optional VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} Vena Cava Filter: Experimental Study in Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Le Blanche, Alain F., E-mail: le_blanche.alain@chu-amiens.fr; Ricco, Jean-Baptiste; Bonneau, Michel

    Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately aftermore » deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter's stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter's stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech{sup Trade-Mark-Sign} Convertible{sup Trade-Mark-Sign} optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.« less

  9. Failed Retrieval of an Inferior Vena Cava Filter During Pregnancy Because of Filter Tilt: Report of Two Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McConville, R. M., E-mail: richard_mcconville@hotmail.com; Kennedy, P. T.; Collins, A. J.

    Thromboembolic disease during pregnancy is an important cause of obstetric morbidity and mortality. Pregnant patients with venous thromboembolism are usually managed by conventional anticoagulation. However, this must be discontinued during vaginal or caesarian delivery to avoid haemorrhage and to reduce the risk of possible epidural haematoma. Retrievable inferior vena cava filters (IVCFs) offer protection against pulmonary embolism during this high-risk period, when anticoagulation is discontinued, while avoiding potential long-term sequelae of a permanent IVCF. Here we report two patients who presented in the third trimester of pregnancy with floating ileofemoral deep vein thrombosis. Both patients were initially treated with standardmore » anticoagulation; however, shortly before delivery both patients had a retrievable IVCF placed in a suprarenal position. In both patients, retrieval failed at 28 days after insertion because of filter tilt. The timing and mechanism of filter tilt remains uncertain. We believe that a number of factors could have been involved, including change in the anatomic configuration with lateral displacement of the IVCF as a result of the gravid uterus as well as forceful uterine contractions during labour, which modified the shape and diameter of the IVC. We showed that failure to retrieve the IVCF has had considerable implications for the two young patients regarding long-term anticoagulation and have highlighted the need for further clinical trials regarding the safe use of retrievable IVCFs during pregnancy.« less

  10. IVC filter placements in children: nationwide comparison of practice patterns at adult and children's hospitals using the Kids' Inpatient Database.

    PubMed

    Wadhwa, Vibhor; Trivedi, Premal S; Ali, Sumera; Ryu, Robert K; Pezeshkmehr, Amir

    2018-02-01

    Inferior vena cava (IVC) filter placement in children has been described in literature, but there is variability with regard to their indications. No nationally representative study has been done to compare practice patterns of filter placements at adult and children's hospitals. To perform a nationally representative comparison of IVC filter placement practices in children at adult and children's hospitals. The 2012 Kids' Inpatient Database was searched for IVC filter placements in children <18 years of age. Using the International Classification of Diseases, 9th Revision (ICD-9) code for filter insertion (38.7), IVC filter placements were identified. A small number of children with congenital cardiovascular anomalies codes were excluded to improve specificity of the code used to identify filter placement. Filter placements were further classified by patient demographics, hospital type (children's and adult), United States geographic region, urban/rural location, and teaching status. Statistical significance of differences between children's or adult hospitals was determined using the Wilcoxon rank sum test. A total of 618 IVC filter placements were identified in children <18 years (367 males, 251 females, age range: 5-18 years) during 2012. The majority of placements occurred in adult hospitals (573/618, 92.7%). Significantly more filters were placed in the setting of venous thromboembolism in children's hospitals (40/44, 90%) compared to adult hospitals (246/573, 43%) (P<0.001). Prophylactic filters comprised 327/573 (57%) at adult hospitals, with trauma being the most common indication (301/327, 92%). The mean length of stay for patients receiving filters was 24.5 days in children's hospitals and 18.4 days in adult hospitals. The majority of IVC filters in children are placed in adult hospital settings. Children's hospitals are more likely to place therapeutic filters for venous thromboembolism, compared to adult hospitals where the prophylactic setting of trauma predominates.

  11. IVC filter retrieval in adolescents: experience in a tertiary pediatric center.

    PubMed

    Guzman, Anthony K; Zahra, Mahmoud; Trerotola, Scott O; Raffini, Leslie J; Itkin, Maxim; Keller, Marc S; Cahill, Anne Marie

    2016-04-01

    Inferior vena cava (IVC) filters are commonly implanted with the intent to prevent life-threatening pulmonary embolism in at-risk patients with contraindications to anticoagulation. Various studies have reported increases in the rate of venous thromboembolism within the pediatric population. The utility and safety of IVC filters in children has not yet been fully defined. To describe the technique and adjunctive maneuvers of IVC filter removal in children, demonstrate its technical success and identify complications. A retrospective 10-year review was performed of 20 children (13 male, 7 female), mean age: 15.1 years (range: 12-19 years), who underwent IVC filter retrieval. Eleven of 20 (55%) were placed in our institution. Electronic medical records were reviewed for filter characteristics, retrieval technique, technical success and complications. The technical success rate was 100%. Placement indications included: deep venous thrombosis with a contraindication to anticoagulation (10/20, 50%), free-floating thrombus (4/20, 20%), post-trauma pulmonary embolism prophylaxis (3/20, 15%) and pre-thrombolysis pulmonary patient (1/20, 5%). The mean implantation period was 63 days (range: 20-270 days). Standard retrieval was performed in 17/20 patients (85%). Adjunctive techniques were performed in 3/20 patients (15%) and included the double-snare technique, balloon assistance and endobronchial forceps retrieval. Median procedure time was 60 min (range: 45-240 min). Pre-retrieval cavogram demonstrated filter tilt in 5/20 patients (25%) with a mean angle of 17° (range: 8-40). Pre-retrieval CT demonstrated strut wall penetration and tip embedment in one patient each. There were two procedure-related complications: IVC mural dissection noted on venography in one patient and snare catheter fracture requiring retrieval in one patient. There were no early or late complications. In children, IVC filter retrieval can be performed safely but may be challenging, especially in cases of filter tilt or embedding. Adjunctive techniques may increase filter retrieval rates.

  12. [Prevalence of stenosis and thrombosis of central veins in hemodialysis after a tunneled jugular catheter].

    PubMed

    Jean, G; Vanel, T; Chazot, C; Charra, B; Terrat, J C; Hurot, J M

    2001-01-01

    Central venous stenosis (ST) and thrombosis (TB) related to catheter (KT) had been reported mostly for the subclavian vein. We performed a systematic cavographic study to evaluate the prevalence of these complications in 51 hemodialysis patients with present or previous history of tunneled internal jugular catheter. Each of them had used one or several KT (1.8 +/- 1.4 KT) for a mean 28 +/- 26 month cumulative time (i.e. 43,584 days total exposure time). Fifty percent of the KT were PermCath Quinton and 50% were Twincath (uncuffed) or CS 100 (cuffed) Medcomp. Twenty-seven had no ST (53%, group I), 24 had one or several significant ST (47%, group II) of superior Vena Cava (SVC, n = 4), inferior Vena Cava (IVC, n = 1), Brachio-cephalic Vein (BCV, n = 5) and subclavian vein (SC, n = 10), or a TB of SVC (n = 1), IVC (n = 3), BCV (n = 3), SC (n = 2). This accounts for an incidence of 0.55 ST or TB/1000 patient-days. Five of the twelve subclavian ST and TB had no history of previous subclavian catheter. Comparison between the two groups showed no differences according to age, time on dialysis, diabetes, hematocrit, CRP, cumulative time with catheter, catheter-related infections, type of catheter and anticoagulant treatment. IVC catheter tip's position is an important risk factor for TB and ST (4/6). Twelve group II patients had ST or TB-related symptoms, with a functional AV fistula in 9 cases. Eleven patients underwent repeated percutaneous angioplasty with 4 additional Wallstents and in 2 cases an AV fistula need to be closed. Central venous ST and TB after a jugular KT is extremely frequent, mostly without any symptoms. Consequences on peripheral or central vascular access, cost and poor long-term patency rate of angioplasty are of major importance. These results incite us to further reduce the catheter use in dialysis patients.

  13. Preliminary evaluation of magnetic resonance fresh blood imaging for diagnosis of Budd-Chiari syndrome.

    PubMed

    Ren, Ke; Xu, Ke; Sun, Wen-ge; Chen, Yu-shuai; Qi, Xi-xun; Li, Ran-liang; Jin, An-yu

    2007-01-20

    Budd-Chiari syndrome (BCS) is a rare disease with portal hypertension caused by the blockage of the hepatic vein and/or the inferior vena cava (IVC). Angiography is the "golden standard" for diagnosis, but it is an invasive examination. To assess the diagnostic value of a fresh blood imaging (FBI) relative to BCS, we used a magnetic resonance angiography (MRA) with an FBI sequence for a preoperative evaluation of the BCS patients in this study. Fifty patients who were suspected of having BCS after they had been checked by a B-ultrasound were studied. 2D and 3D FBI were performed on a 1.5T superconductive MR scanner. Original images were rebuilt using a maximal intensity projection (MIP) method on the console. Two doctors reviewed all images before they learned of the angiography results. We then compared the diagnoses obtained from the FBI and angiography results to evaluate the diagnostic value of the FBI. Forty-one patients were diagnosed as BCS and 9 as non-BCS based on an angiography. The FBI correctly diagnosed 38 patients, incorrectly diagnosed 1 patient, and missed diagnosis in 3 patients. Thus, the diagnostic sensitivity of the FBI is 93% (38/41), the specificity is 89% (8/9) and the accuracy is 92% (46/50). The FBI images of the 13 membranous stenoses of the IVC showed a sudden stenosis of the post-liver segment of the IVC. The Images of the 5 patients with a membranous obstruction of the IVC showed IVC thickening and an absence of blood signals in the post-hepatic segment of the IVC. The images of the 4 patients with the segmental thrombosis of the IVC showed abnormal and intermittent signals in the IVC. The images of the 6 patients with a simple hepatic vein obstruction showed obstructive hepatic veins. The images of the 6 patients with the stenosis of both the IVC and the hepatic veins showed the stenosis of the IVC, the thickening of the hepatic veins and the formation of a compensatory circulation within the liver. Lastly, the images of the 7 patients showed a combination of the IVC thrombosis with stenosis or with the obstruction of one or two hepatic veins. An FBI can show a membranous stenosis, and an obstruction and thrombosis of the IVC. In addition, it can also demonstrate the thickening of the flexural hepatic vein and the development of intra-hepatic compensatory branches with slow blood flow. Thus, it can guide the puncturing and opening of the hepatic vein involved in an interventional therapy for BCS patients.

  14. Caval penetration by retrievable inferior vena cava filters: a retrospective comparison of Option and Günther Tulip filters.

    PubMed

    Olorunsola, Olufoladare G; Kohi, Maureen P; Fidelman, Nicholas; Westphalen, Antonio C; Kolli, Pallav K; Taylor, Andrew G; Gordon, Roy L; LaBerge, Jeanne M; Kerlan, Robert K

    2013-04-01

    To compare the frequency of vena caval penetration by the struts of the Option and Günther Tulip cone filters on postplacement computed tomography (CT) imaging. All patients who had an Option or Günther Tulip inferior vena cava (IVC) filter placed between January 2010 and May 2012 were identified retrospectively from medical records. Of the 208 IVC filters placed, the positions of 58 devices (21 Option filters, 37 Günther Tulip filters [GTFs]) were documented on follow-up CT examinations obtained for reasons unrelated to filter placement. In cases when multiple CT studies were obtained after placement, each study was reviewed, for a total of 80 examinations. Images were assessed for evidence of caval wall penetration by filter components, noting the number of penetrating struts and any effect on pericaval tissues. Penetration of at least one strut was observed in 17% of all filters imaged by CT between 1 and 447 days following placement. Although there was no significant difference in the overall prevalence of penetration when comparing the Option filter and GTF (Option, 10%; GTF, 22%), only GTFs showed time-dependent penetration, with penetration becoming more likely after prolonged indwelling times. No patient had damage to pericaval tissues or documented symptoms attributed to penetration. Although the Günther Tulip and Option filters exhibit caval penetration at CT imaging, only the GTF exhibits progressive penetration over time. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  15. Does CT evidence of a flat inferior vena cava indicate hypovolemia in blunt trauma patients with solid organ injuries?

    PubMed

    Liao, Yu-Ying; Lin, Hung-Jung; Lu, Yu-Hui; Foo, Ning-Ping; Guo, How-Ran; Chen, Kuo-Tai

    2011-06-01

    Nonoperative management for selective patients with solid organ injuries from blunt trauma has gained wide acceptance. However, for trauma surgeons, it is often difficult to estimate a patient's circulatory volume. Some authors have proposed that the presence of a collapsed inferior vena cava (IVC) on computed tomography (CT) scan correlates with inadequate circulatory volume. Our aim was to verify whether CT evidence of a flat IVC (FI) is an indicator of hypovolemia in blunt trauma patients with solid organ injuries. We conducted a retrospective chart review of all blunt trauma patients with solid organ injuries admitted to our Medical Center from July 2003 to September 2006. Of the 226 patients reviewed, 29 had CT evidence of FI. We compared Injury Severity Scores, hemodynamic parameters, fluid and blood transfusion requirements, mortality rate, and hospital course between patients with (FI group) and without FI (non-FI [NFI] group). The FI group had higher rates of intensive care unit admission and mortality, in addition to longer intensive care unit stays, when compared with the NFI group. In addition, the patients in the FI group needed larger amounts of fluid and blood transfusions and presented lower hemoglobin levels during the first week of admission; furthermore, the majority deteriorated to a state of shock in the emergency department. CT evidence of FI is a good indicator of hypovolemia and an accurate predictor for prognosis in trauma patients with blunt solid organ injuries.

  16. One-stage surgery for removal of intravascular leiomyomatosis extending to right ventricle.

    PubMed

    Chiang, Ching-Shu; Chen, Po-Lin; Kuo, Tzu-Ting; Chen, I-Ming; Wu, Nai-Yuan; Chang, Hsiao-Huang

    2018-03-01

    Intravascular leiomyomatosis (IVL) is a rare nonmalignant tumor that can be fatal if untreated. A 49-year-old nulliparous Asian woman who underwent hysterectomy and left salpingo-oophorectomy for multiple uterine leiomyomas 18 months prior presented complaining of intermittent palpitation and chest tightness for approximately 1 month. Echocardiography revealed a large mobile tumor mass extending from the inferior vena cava (IVC) to the right atrium that partially obstructed IVC flow and tricuspid inflow. Thoracicabdominopelvic computed tomography revealed a left adnexal tumor (4.8 × 2.5 cm) causing intravascular obstruction extending from the left internal iliac vein to the IVC, right atrium, and right ventricle. IVL with right heart involvement INTERVENTIONS:: Under cardiopulmonary bypass, a one-stage surgery combining sternotomy and laparotomy was performed. The tumor was approached and extracted via sternotomy, and tumor detachment and removal of residual tumors was accomplished via laparotomy. A firm, smooth, and regularly shape tumor 15.5 × 5.5 × 2.5 in size was completely removed and histopathologically confirmed as IVL. The patient tolerated the surgical procedure well and no postoperative complication was noted. We describe a one-stage surgical approach to completely remove an IVL extending to the right ventricle.

  17. Complex left profunda femoris vein to renal vein bypass for the management of progressive chronic iliofemoral occlusion.

    PubMed

    Anaya-Ayala, Javier E; Adams, Matthew K; Telich-Tarriba, Jose E; Dresser, Kelly L; Ismail, Nyla; Peden, Eric K

    2013-01-01

    Chronic occlusions of the inferior vena cava (IVC) and iliofemoral veins are long-term sequelae of deep venous thrombosis (DVT) that can lead to postthrombotic syndrome (PTS). Patients may present with a wide spectrum of signs and symptoms, ranging from mild discomfort and swelling to severe venous hypertension and ulcerations. We report a 68-year-old man who had a history of left lower extremity DVT after a laminectomy and who developed PTS with nonhealing ulcers. The patient underwent a cross-pubic femorofemoral venous bypass that failed to improve his clinical status. After unsuccessful endovascular attempts for recanalization of the iliofemoral segment, a profunda femoris to IVC bypass was performed. The symptoms recurred 2 years later. Venography revealed restenosis at the caval anastomosis that did not resolve by endovascular means. A surgical revision was performed, and given the quality of the IVC, a jump bypass was created to the left renal vein. The swelling improved and the ulcers healed completely. Twenty-eight months after the complex reconstructions, he remains ulcer-free with mild edema controlled with stockings. Venous reconstructions remain a viable option for patients with symptomatic and recalcitrant nonmalignant obstruction of the large veins. Copyright © 2013 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  18. Swine Model of Thrombotic Caval Occlusion Created by Autologous Thrombus Injection with Assistance of Intra-caval Net Knitting

    PubMed Central

    Shi, Wan-Yin; Wu, Shuang; Hu, Lan-Yue; Liu, Chang-Jian; Gu, Jian-Ping

    2015-01-01

    To evaluate the feasibility of a swine model of thrombotic inferior vena cava (IVC) occlusion (IVCO) created by autologous thrombus injection with assistance of intra-caval net knitting. Sixteen pigs were included and divided into two groups: Group A (n = 10), IVCO model created by knitting a caval net followed by autologous thrombus injection; Group B (n = 6), control model created by knitting a net and normal saline injection. Venography was performed to assess each model and the associated thrombotic occlusion. The vessels were examined histologically to analyse the pathological changes postoperatively. IVCO model was successfully created in 10 animals in Group A (100%). Immediate venography showed extensive clot burden in the IVC. Postoperative venography revealed partial caval occlusion at 7 days, and complete occlusion coupled with collateral vessels at 14 days. Histologically, Group A animals had significantly greater venous wall thickening, with CD163-positive and CD3-positive cell infiltration. Recanalization channels were observed at the margins of the thrombus. By contrast, no thrombotic occlusion of the IVC was observed in Group B. The thrombotic IVCO model can be reliably established in swine. The inflammatory reaction may contribute to the caval thrombus propagation following occlusion. PMID:26680253

  19. Serial cardiac MRIs in adult Fontan patients detect progressive hepatic enlargement and congestion.

    PubMed

    Lewis, Matthew J; Hecht, Elizabeth; Ginns, Jonathan; Benton, Joshua; Prince, Martin; Rosenbaum, Marlon S

    2017-03-01

    The progression of hepatic disease in adult Fontan patients is not well understood. They reviewed the experience with serial cardiac MRIs (CMR) in adult Fontan patients to determine if hepatic anatomic markers of prolonged Fontan exposure were present and if clinical predictors of progressive hepatic congestion could be identified. A retrospective cohort study of all adult Fontan patients who had undergone at least two CMRs was performed. Hepatic dimensions, inferior vena cava (IVC) size, right hepatic vein (RHV) size and spleen diameter were determined from images acquired at the time of clinically guided CMR. Two radiologists with expertise in hepatic imaging graded congestion and liver size independently using post-gadolinium contrast sequences. Twenty-seven patients met inclusion criteria. Over a mean time of 5.1 years between CMRs, there was a significant increase in mean lateral-medial hepatic dimension (P = .005), mean RHV diameter (P = .004), and mean splenic diameter (P = .001). Serial post-gadolinium imaging was available in 25/27 (93%) patients of which 15/27 (55%) showed evidence of progressive hepatic congestion across serial studies. Progressive hepatic congestion was associated with single ventricle ejection fraction (SVEF) less than 50% (P = .008), and larger indexed end-diastolic (EDVI) and end-systolic volume (ESVI). RHV diameter was the only anatomic variable significantly correlated with time from Fontan completion (P = .004). Serial CMRs detected progressive liver and hepatic vein enlargement in our cohort of adult Fontan patients over a mean time of 5.2 years. Progressive hepatic congestion occurs in a significant number of adult Fontan patients and may be associated with ventricular enlargement and decreased ventricular function by CMR. © 2016 Wiley Periodicals, Inc.

  20. Budd-Chiari Syndrome Due to Protein C Deficiency: A Rare Disorder to cause Chronic Liver Disease.

    PubMed

    Begum, Rukshana; Mahtab, Mamun Al; Mamun, Ayub Al; Moben, Ahmed Lutful; Hossain, Sharker Mohammad Shahadat; Das, Dulal Chandra; Malakar, Debraj; Or Rashid, Harun; Roy, Partho Protim; Rahman, Salimur

    2016-01-01

    The Budd-Chiari syndrome (BCS) is a rare disorder due to chronic liver disease (CLD), which is caused by the obstruction of hepatic venous outflow that can be located at any place from the small hepatic venules up to the entrance of the inferior vena cava (IVC) into the right atrium. Among the causes of BCS, the rarer one is coagulation factor deficiencies. Here, we report a case of BCS associated with deficiency of protein C resulting in thrombus in IVC. The patient was a 50-year-old male, who had been suffering from recurrent abdominal and leg swelling for a long period of 7 years. He was evaluated thoroughly, and other causes of liver cirrhosis were excluded. Begum R, Al Mahtab M, Al Mamun A, Moben AL, Hossain SMS, Das DC, Malakar D, Rashid HO, Roy PP, Rahman S. Budd-Chiari Syndrome Due to Protein C Deficiency: A Rare Disorder to cause Chronic Liver Disease. Euroasian J Hepato-Gastroenterol 2016;6(2):194-197.

  1. En-bloc Transplantation: an Eligible Technique for Unilateral Dual Kidney Transplantation

    PubMed Central

    Salehipour, M.; Bahador, A.; Nikeghbalian, S.; Kazemi, K.; Shamsaeifar, A. R.; Ghaffaripour, S.; Sahmeddini, M. A.; Salahi, H.; Bahreini, A.; Janghorban, P.; Gholami, S.; Malek-Hosseini, S. A.

    2012-01-01

    Background: Kidney transplantation is the best available treatment for patients with end-stage renal disease. Objective: To evaluate the en bloc anastomosis technique for unilateral dual kidney transplantation (DKT). Methods: From May to October 2011, 5 patients (4 women and 1 man) with mean age of 31.8 years underwent unilateral DKT with this technique in which distal end of the aorta and proximal end of inferior vena cava (IVC) were closed with running sutures. Then, proximal end of the aorta and distal end of the IVC were anastomosed to internal (or external) iliac artery and external iliac vein, respectively. Results: Post-operative course was uneventful. No vascular and urologic complications developed; all patient had acceptable serum creatinine at discharge time and up of 2–6 months of post-operation follow up. Conclusion: Unilateral DKT is a safe method for performing DKT. The proposed en bloc anastomosis can improve the outcome of the graft by reducing the cold ischemia and the operation time. PMID:25013633

  2. En-bloc Transplantation: an Eligible Technique for Unilateral Dual Kidney Transplantation.

    PubMed

    Salehipour, M; Bahador, A; Nikeghbalian, S; Kazemi, K; Shamsaeifar, A R; Ghaffaripour, S; Sahmeddini, M A; Salahi, H; Bahreini, A; Janghorban, P; Gholami, S; Malek-Hosseini, S A

    2012-01-01

    Kidney transplantation is the best available treatment for patients with end-stage renal disease. To evaluate the en bloc anastomosis technique for unilateral dual kidney transplantation (DKT). From May to October 2011, 5 patients (4 women and 1 man) with mean age of 31.8 years underwent unilateral DKT with this technique in which distal end of the aorta and proximal end of inferior vena cava (IVC) were closed with running sutures. Then, proximal end of the aorta and distal end of the IVC were anastomosed to internal (or external) iliac artery and external iliac vein, respectively. Post-operative course was uneventful. No vascular and urologic complications developed; all patient had acceptable serum creatinine at discharge time and up of 2-6 months of post-operation follow up. Unilateral DKT is a safe method for performing DKT. The proposed en bloc anastomosis can improve the outcome of the graft by reducing the cold ischemia and the operation time.

  3. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uller, Wibke, E-mail: wibke.uller@klinik.uni-regensburg.de; Knoppke, Birgit; Schreyer, Andreas G.

    Purpose: Evaluation of the efficacy and safety of percutaneous treatment of vascular stenoses and occlusions in pediatric liver transplant recipients. Methods: Fifteen children (mean age 8.3 years) underwent interventional procedures for 18 vascular complications after liver transplantation. Patients had stenoses or occlusions of portal veins (n = 8), hepatic veins (n = 3), inferior vena cava (IVC; n = 2) or hepatic arteries (n = 5). Technical and clinical success rates were evaluated. Results: Stent angioplasty was performed in seven cases (portal vein, hepatic artery and IVC), and sole balloon angioplasty was performed in eight cases. One child underwent thrombolysismore » (hepatic artery). Clinical and technical success was achieved in 14 of 18 cases of vascular stenoses or occlusions (mean follow-up 710 days). Conclusion: Pediatric interventional radiology allows effective and safe treatment of vascular stenoses after pediatric liver transplantation (PLT). Individualized treatment with special concepts for each pediatric patient is necessary. The variety, the characteristics, and the individuality of interventional management of all kinds of possible vascular stenoses or occlusions after PLT are shown.« less

  5. Mechanisms of Günther Tulip filter tilting during transfemoral placement.

    PubMed

    Matsui, Y; Horikawa, M; Ohta, K; Jahangiri Noudeh, Y; Kaufman, J A; Farsad, K

    The purpose of this study was to characterize the mechanisms of Günther Tulip filter (GTF) tilting during transfemoral placement in an experimental model with further validation in a clinical series. In an experimental study, 120 GTF placements in an inferior vena cava (IVC) model were performed using 6 configurations of pre-deployment filter position. The angle between the pre-deployment filter axis and IVC axis, and the proximity of the constrained filter legs to IVC wall prior to deployment were evaluated. The association of those pre-deployment factors with post-deployment filter tilting was analyzed. The association noted in the experimental study was then evaluated in a retrospective clinical series of 21 patients. In the experimental study, there was a significant association between the pre-deployment angle and post-deployment filter tilting (P<0.0001). With a low pre-deployment angle (≤5°), a significant association was noted between filter tilting and the proximity of the constrained filter legs to the far IVC wall (P=0.001). In a retrospective clinical study, a significant association between the pre-deployment angle and post-deployment filter tilting was also noted with a linear regression model (P=0.026). Significant association of the pre-deployment angle with post-deployment GTF tilting was shown in both the experimental and clinical studies. The experimental study also showed that proximity of filter legs is relevant when pre-deployment angle is small. Addressing these factors may result in a lower incidence of filter tilting. Copyright © 2017 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  6. The Mid-Term Efficacy and Safety of a Permanent Nitinol IVC Filter (TrapEase)

    PubMed Central

    Liu, Wei Chiang; Choo, Sung Wook; Kim, Dong-Ik; Kim, Young Wook; Kim, Duk-Kyung; Shin, Sung Wook; Park, Kwang Bo; Jeon, Yong Hwan; Choo, In-Wook

    2005-01-01

    Objective 1) To evaluate the mid-term efficacy and safety of a permanent nitinol inferior vena cava (IVC) filter; 2) to evaluate filter effectiveness, filter stability and caval occlusion. Materials and Methods A prospective evaluation of the TrapEase IVC filter was performed on 42 patients (eight men, 34 women) ranging in age from 22 to 78 years (mean age 66 years). All patients were ill with a high risk of pulmonary embolism (PE). Indications for filter placement were: 1) deep vein thrombosis with recurrent thromboembolism; 2) and/or free-floating thrombus with contraindication to anticoagulation; and 3) complications in achieving adequate anticoagulation. Follow-up evaluations (mean: 15.4 months, range: 2 to 28 months) were performed at 6- and 12-month intervals after the procedure and included clinical histories, chart reviews, plain film, Doppler ultrasounds, and contrasted abdominal CT scans. Results In follow-up evaluations, the data analysis revealed no cases of symptomatic PE. There were no cases of filter migration, insertion site thrombosis, filter fracture, or vessel wall perforation. During the study, there was one case of filter thrombosis; early symptomatic thrombosis that was successfully treated in the hospital. Of the 42 subjects, eight died. These deaths were not related to the filter device or the implantation procedure, but to the underlying disease. Conclusion This study demonstrates that the TrapEase permanent IVC filter is a safe and an effective device with low complication rates and is best used in patients with thromboembolic disease with a high risk of PE. PMID:15968150

  7. Distension of central great vein decreases sympathetic outflow in humans

    PubMed Central

    Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D.; Mast, Jessica

    2013-01-01

    Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ∼27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans. PMID:23729210

  8. Distension of central great vein decreases sympathetic outflow in humans.

    PubMed

    Cui, Jian; Gao, Zhaohui; Blaha, Cheryl; Herr, Michael D; Mast, Jessica; Sinoway, Lawrence I

    2013-08-01

    Classic canine studies suggest that central great vein distension evokes an autonomic reflex tachycardia (Bainbridge reflex). It is unclear whether central venous distension in humans is a necessary and sufficient stimulus to evoke a reflex increase in heart rate (HR), blood pressure (BP), and muscle sympathetic nerve activity (MSNA). Prior work from our laboratory suggests that limb venous distension evokes a reflex increase in BP and MSNA in humans. We hypothesized that in humans, compared with the limb venous distension, inferior vena cava (IVC) distension would evoke a less prominent increase in HR and MSNA. IVC distension (monitored with ultrasonography) was induced by two methods: 1) head-down tilt (HDT, N = 13); and 2) lower-body positive pressure (LBPP, N = 10). Two minutes of HDT induced IVC distension (Δ2.6 ± 0.2 mm, P < 0.001, ~27% in cross-sectional area), slightly increased mean BP (Δ2.3 ± 0.7 mmHg, P = 0.005), decreased MSNA (Δ5.2 ± 0.8 bursts/min, P < 0.001, N = 10), and did not alter HR (P = 0.37). LBPP induced similar IVC distension, increased BP (Δ2.0 ± 0.7 mmHg, P < 0.01), and did not alter HR (P = 0.34). Thus central venous distension leads to a rapid increase in BP and a subsequent fall in MSNA. Central venous distension does not evoke either bradycardia or tachycardia in humans. The absence of a baroreflex-mediated bradycardia suggests that the Bainbridge reflex is engaged. Clearly, this reflex differs from the powerful sympathoexcitation peripheral venous distension reflex described in humans.

  9. Polymer-Based Reconstruction of the Inferior Vena Cava in Rat: Stem Cells or RGD Peptide?

    PubMed Central

    Pontailler, Margaux; Illangakoon, Eranka; Williams, Gareth R.; Marijon, Camille; Bellamy, Valérie; Balvay, Daniel; Autret, Gwenhael; Vanneaux, Valérie; Larghero, Jérôme; Planat-Benard, Valérie; Perier, Marie-Cécile; Bruneval, Patrick; Menasché, Philippe

    2015-01-01

    As part of a program targeted at developing a resorbable valved tube for replacement of the right ventricular outflow tract, we compared three biopolymers (polyurethane [PU], polyhydroxyalkanoate (the poly(3-hydroxybutyrate-co-3-hydroxyvalerate-co-4-hydroxyvalerate) [PHBVV]), and polydioxanone [PDO]) and two biofunctionalization techniques (using adipose-derived stem cells [ADSCs] or the arginine-glycine-aspartate [RGD] peptide) in a rat model of partial inferior vena cava (IVC) replacement. Fifty-three Wistar rats first underwent partial replacement of the IVC with an acellular electrospun PDO, PU, or PHBVV patch, and 31 nude rats subsequently underwent the same procedure using a PDO patch biofunctionalized either by ADSC or RGD. Results were assessed both in vitro (proliferation and survival of ADSC seeded onto the different materials) and in vivo by magnetic resonance imaging (MRI), histology, immunohistochemistry [against markers of vascular cells (von Willebrand factor [vWF], smooth muscle actin [SMA]), and macrophages ([ED1 and ED2] immunostaining)], and enzyme-linked immunosorbent assay (ELISA; for the expression of various cytokines and inducible NO synthase). PDO showed the best in vitro properties. Six weeks after implantation, MRI did not detect significant luminal changes in any group. All biopolymers were evenly lined by vWF-positive cells, but only PDO and PHBVV showed a continuous layer of SMA-positive cells at 3 months. PU patches resulted in a marked granulomatous inflammatory reaction. The ADSC and RGD biofunctionalization yielded similar outcomes. These data confirm the good biocompatibility of PDO and support the concept that appropriately peptide-functionalized polymers may be successfully substituted for cell-loaded materials. PMID:25611092

  10. Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results.

    PubMed

    Reis, Stephen P; Kovoor, Jerry; Sutphin, Patrick D; Toomay, Seth; Trimmer, Clayton; Pillai, Anil; Reddick, Mark; Kalva, Sanjeeva P

    2016-08-01

    The purpose of the study is to evaluate the clinical safety and effectiveness of the Denali (Bard, Tempe, Arizona) retrievable inferior vena cava (IVC) filter. In this retrospective study, authors reviewed the data of Denali IVC filters placed at their institution between 2013 and 2015. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. The frequency of post filter pulmonary embolism (PE) and filter-related complications was assessed. Denali filters were placed in 87 patients (47 males; mean age: 56 years). Twenty patients presented with PE, 45 with deep vein thrombosis (DVT), and 21 with both PE and DVT, 1 filter was placed prophylactically before surgery. Indications for filter placement included contraindications to anticoagulation (AC; n = 80), failure of AC (n = 4), and complications of AC (n = 3). No patients had PE on follow-up imaging after filter placement. Retrieval was attempted in 31 patients after a mean period of 125 days (range: 34-324 days). The filter was successfully removed in 31 (100%) patients. Follow-up imaging, available in 71 (82%) patients (range: 2-538 days), demonstrated penetration of 15 legs in 5 patients, caval thrombus in 3, 1 resulting in caval occlusion, <15° filter tilt in 5, and no leg fractures or crossed legs. The Denali filter is safe during deployment and readily retrievable. The overall safety following deployment is similar to those reported in the literature, and the incidence of filter fractures and migration appears to be less than the previous generation of Bard devices. © The Author(s) 2016.

  11. Liver Stiffness Reflecting Right-Sided Filling Pressure Can Predict Adverse Outcomes in Patients With Heart Failure.

    PubMed

    Taniguchi, Tatsunori; Ohtani, Tomohito; Kioka, Hidetaka; Tsukamoto, Yasumasa; Onishi, Toshinari; Nakamoto, Kei; Katsimichas, Themistoklis; Sengoku, Kaoruko; Chimura, Misato; Hashimoto, Haruko; Yamaguchi, Osamu; Sawa, Yoshiki; Sakata, Yasushi

    2018-01-12

    This study sought to investigate whether elevated liver stiffness (LS) values at discharge reflect residual liver congestion and are associated with worse outcomes in patients with heart failure (HF). Transient elastography is a newly developed, noninvasive method for assessing LS, which can be highly reflective of right-sided filling pressure associated with passive liver congestion in patients with HF. LS values were determined for 171 hospitalized patients with HF before discharge using a Fibroscan device. The median LS value was 5.6 kPa (interquartile range: 4.4 to 8.1; range 2.4 to 39.7) and that of right-sided filling pressure, which was estimated based on LS, was 5.7 mm Hg (interquartile range: 4.1 to 8.2 mm Hg; range 0.1 to 18.9 mm Hg). The patients in the highest LS tertile (>6.9 kPa, corresponding to an estimated right-sided filling pressure of >7.1 mm Hg) had advanced New York Heart Association functional class, high prevalence of jugular venous distention and moderate/severe tricuspid regurgitation, large inferior vena cava (IVC) diameter, low hemoglobin and hematocrit levels, high serum direct bilirubin level, and a similar left ventricular ejection fraction compared with the lower tertiles. During follow-up periods (median: 203 days), 8 (5%) deaths and 33 (19%) hospitalizations for HF were observed. The patients in the highest LS group had a significantly higher mortality rate and HF rehospitalization (hazard ratio: 3.57; 95% confidence interval: 1.93 to 6.83; p < 0.001) compared with the other tertiles. Although LS correlated with IVC diameter and serum direct bilirubin and brain natriuretic peptide levels, LS values were predictive of worse outcomes, even after adjustment for these indices. These data suggest that LS is a useful index for assessing systemic volume status and predicting the severity of HF, and that the presence of liver congestion at discharge is associated with worse outcomes in patients with HF. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Should we isolate human preantral follicles before or after cryopreservation of ovarian tissue?

    PubMed

    Vanacker, Julie; Luyckx, Valérie; Amorim, Christiani; Dolmans, Marie-Madeleine; Van Langendonckt, Anne; Donnez, Jacques; Camboni, Alessandra

    2013-04-01

    To evaluate the survival and growth potential of human preantral follicles isolated before and after cryopreservation. Pilot study. Gynecology research unit in a university hospital. Six women aged 27 to 32 years. Six ovarian biopsy samples were cut into two equal parts, half subjected to slow-freezing followed by follicle isolation (cryo-iso group) and alginate-matrigel embedding, and half immediately processed for follicle isolation and alginate-matrigel embedding followed by slow-freezing (iso-cryo group) or used as fresh controls (fresh group). Follicle number, viability, diameter, and morphology. After 1,134 preantral follicles had been isolated from fresh biopsy samples and 1,132 from frozen specimens, the three groups were compared before and after 7 days of in vitro culture (IVC) in alginate-matrigel beads. No statistically significant differences in viability were found between the three groups before or after IVC, but follicle diameter increased in all three groups after IVC. Morphology analysis revealed well-preserved follicles in both the iso-cryo and cryo-iso groups after IVC. Human preantral follicles can be successfully cryopreserved before or after isolation without impairing their ability to survive and grow in vitro. This could lead to development of new protocols for follicle cryopreservation, IVC, and grafting in clinical and research settings for fertility preservation. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Utility of Retrievable Inferior Vena Cava Filters: A Systematic Literature Review and Analysis of the Reasons for Nonretrieval of Filters with Temporary Indications.

    PubMed

    Jia, Zhongzhi; Fuller, Tyler A; McKinney, J Mark; Paz-Fumagalli, Ricardo; Frey, Gregory T; Sella, David M; Van Ha, Thuong; Wang, Weiping

    2018-05-01

    To investigate the use of retrievable inferior vena cava (IVC) filters in the current practice and analyze the causes of filter left in situ despite initial plans for retrieval. A systematic search of all English-language studies of retrievable IVC filters was conducted, including clinical trials and observational studies published between January 1984 and March 2016. A total of 103 studies were identified, including 10 filter models in 20,319 patients. Placement indications were reported for 11,128 (54.8%) patients, including therapeutic (n = 6270; 56.3%) and prophylactic (n = 4858; 43.7%) indications. A total of 13,224 (65.1%) filters were left as permanent devices; 7095 (34.9%) filters were removed. The reasons for filter nonretrieval among the 5308 (40.1%) reported cases were primary permanent indication (21.2%; 1127/5308), death (19.4%; 1031/5308), ongoing pulmonary embolism (PE) protection (19.0%; 1011/5308), failed retrieval (13.7%; 725/5308), loss to follow-up (13.0%; 689/5308), discontinued care (4.4%; 235/5308), physician oversight (4.0%; 213/5308), patient morbidity (2.8%; 149/5308), and patient refusal (2.4%; 128/5308). A total of 7820 patients presented for filter retrieval, and 7095 filters (90.7%) were successfully removed, with a mean indwelling time of 106.6 ± 47.3 days. Breakthrough PE was reported in 2.1% (191/9169) of patients. Filter tilt, recurrent deep vein thrombosis, penetration, IVC thrombosis, migration, and fracture occurred in 7.7% (798/10,348), 7.1% (362/5092), 5.4% (379/7001), 3.9% (345/8788), 1.4% (160/11,679), and 0.5% (50/9509) of patients, respectively. Approximately two-thirds of retrievable filters were not retrieved even though more than 85% of the filters were initially intended for temporary use. The major reasons for filter left in situ despite initial plans for retrieval were death, need for ongoing PE protection, failed retrieval, loss to follow-up, discontinued care, and physician oversight.

  14. Long-term Outcomes of Percutaneous Venoplasty and Gianturco Stent Placement to Treat Obstruction of the Inferior Vena Cava Complicating Liver Transplantation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lorenz, Jonathan M., E-mail: jlorenz@radiology.bsd.uchicago.edu; Beek, Darren van; Funaki, Brian

    PurposeEvaluation of long-term outcomes of venoplasty and Gianturco stents to treat inferior vena cava (IVC) obstruction after liver transplantation.MethodsWe retrospectively analyzed records from 33 consecutive adult patients referred with the intent to treat suspected IVC obstruction after liver transplantation. Treatment was performed for occlusion or stenosis with a gradient exceeding 3 mmHg. The primary treatment was venoplasty and, if refractory, Gianturco stent placement. Recurrence prompted repeat venoplasty or stent placement.ResultsOf the 33 patients, 25 (aged 46.9 ± 12.2 years) required treatment at a mean of 2.3 years (14 days to 20.3 years) after transplantation. For technically successful cases, primary treatment was venoplasty alone (14) or with stentmore » placement (10). Technical success was 96 % (24 of 25) reflecting failure to cross one occlusion. Clinical success was 88 % (22 of 25) reflecting the technical failure and two that died of unrelated complications within 5 weeks. Cumulative primary patencies were 57.1 % at 6 months (n = 21) and 51.4 % at 1 (n = 10), 3 (n = 7), 5 (n = 6), and 7 (n = 5) years. Cumulative primary assisted patency was 95.2 % at 6 months (n = 21) and at 1 (n = 15), 3 (n = 9), 5 (n = 8), and 7 (n = 8) years. The 17 patients stented for refractory (n = 10) or recurrent (n = 7) stenosis had cumulative primary and primary assisted patencies of 86.0 and 100 %, respectively, from 6 months (n = 14) to 7 years (n = 3). No major complications occurred; one fractured stent was observed after 11.6 years.ConclusionFor IVC obstruction following liver transplantation, excellent long-term outcomes can be achieved by venoplasty and Gianturco stent placement.« less

  15. Modeling Flow Past a Tilted Vena Cava Filter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Wang, S L

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside amore » model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.« less

  16. Residual tumor size and IGCCCG risk classification predict additional vascular procedures in patients with germ cell tumors and residual tumor resection: a multicenter analysis of the German Testicular Cancer Study Group.

    PubMed

    Winter, Christian; Pfister, David; Busch, Jonas; Bingöl, Cigdem; Ranft, Ulrich; Schrader, Mark; Dieckmann, Klaus-Peter; Heidenreich, Axel; Albers, Peter

    2012-02-01

    Residual tumor resection (RTR) after chemotherapy in patients with advanced germ cell tumors (GCT) is an important part of the multimodal treatment. To provide a complete resection of residual tumor, additional surgical procedures are sometimes necessary. In particular, additional vascular interventions are high-risk procedures that require multidisciplinary planning and adequate resources to optimize outcome. The aim was to identify parameters that predict additional vascular procedures during RTR in GCT patients. A retrospective analysis was performed in 402 GCT patients who underwent 414 RTRs in 9 German Testicular Cancer Study Group (GTCSG) centers. Overall, 339 of 414 RTRs were evaluable with complete perioperative data sets. The RTR database was queried for additional vascular procedures (inferior vena cava [IVC] interventions, aortic prosthesis) and correlated to International Germ Cell Cancer Collaborative Group (IGCCCG) classification and residual tumor volume. In 40 RTRs, major vascular procedures (23 IVC resections with or without prosthesis, 11 partial IVC resections, and 6 aortic prostheses) were performed. In univariate analysis, the necessity of IVC intervention was significantly correlated with IGCCCG (14.1% intermediate/poor vs 4.8% good; p=0.0047) and residual tumor size (3.7% size < 5 cm vs 17.9% size ≥ 5 cm; p < 0.0001). In multivariate analysis, IVC intervention was significantly associated with residual tumor size ≥ 5 cm (odds ratio [OR]: 4.61; p=0.0007). In a predictive model combining residual tumor size and IGCCCG classification, every fifth patient (20.4%) with a residual tumor size ≥ 5 cm and intermediate or poor prognosis needed an IVC intervention during RTR. The need for an aortic prosthesis showed no correlation to either IGCCCG (p=0.1811) or tumor size (p=0.0651). The necessity for IVC intervention during RTR is correlated to residual tumor size and initial IGCCCG classification. Patients with high-volume residual tumors and intermediate or poor risk features must initially be identified as high-risk patients for vascular procedures and therefore should be referred to specialized surgical centers with the ad hoc possibility of vascular interventions. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  17. Rosuvastatin reduced deep vein thrombosis in ApoE gene deleted mice with hyperlipidemia through non-lipid lowering effects

    PubMed Central

    Patterson, K.A.; Zhang, X.; Wrobleski, S.K.; Hawley, A.E.; Lawrence, D. A.; Wakefield, T.W.; Myers, D.D.; Diaz, J.A.

    2013-01-01

    Introduction Statins, particularly rosuvastatin, have recently become relevant in the setting of venous thrombosis. The objective of this study was to study the non-lipid lowering effects of rosuvastatin in venous thrombosis in mice with hyperlipidemia. Materials and Methods An inferior vena cava ligation model of venous thrombosis in mice was utilized. Saline or 5mg/kg of rosuvastatin was administered by gavage 48hs previous thrombosis. Blood, the inferior vena cava, thrombus, and liver were harvested 3, 6 hours, and 2 days post-thrombosis. Thrombus weight, inflammatory markers, and plasminogen activator inhibitor-1 expression and plasma levels were measured and neutrophil migration to the IVC was assessed. Results Rosuvastatin significantly decreased thrombus weight, plasminogen activator inhibitor-1 expression and plasma levels, expression of molecules related to the interleukin-6 pathway, and neutrophil migration into the vein wall. Conclusions This work supports the beneficial effects of rosuvastatin on venous thrombosis in mice with hyperlipidemia due to its non-lipid lowering effects. PMID:23276528

  18. Renal cell carcinoma with thrombus extending to the hepatic veins or right atrium: operative strategies based on 41 consecutive patients.

    PubMed

    Gagné-Loranger, Maude; Lacombe, Louis; Pouliot, Frédéric; Fradet, Vincent; Dagenais, François

    2016-08-01

    The natural history of renal cell carcinoma (RCC) with tumour thrombus extending at or above the hepatic veins is dismal. Different surgical approaches have been described including cardiopulmonary bypass (CPB) with deep hypothermic circulatory arrest. We here report our experience in terms of surgical techniques and outcomes on 41 consecutive patients presenting an RCC extending to the hepatic veins or the right atrium. A surgical decision-making algorithm is discussed. Retrospective review of 41 patients operated for RCC extending in the retrohepatic vena cava (extent level III-IV) between 2000 and 2015. Patients were operated by a dedicated urology/cardiac surgery team. The mean age was 62.6 ± 10.4 years; 39% were female. Surgery was emergent in 7.3% of patients, 2.4% of patients had preoperative dialysis, 4.9% required a redo sternotomy and 19.5% had coronary artery disease. Tumour thrombus extended above the diaphragm in 23 patients (level IV) and to the level of hepatic veins (level III) in 18 patients. CPB was used in 38 patients. Arterial cannulation was in the aorta or femoral artery in 14 patients during the initial experience. In the current era, the axillary artery and the innominate artery were used in 12 patients each. Mean CPB, cross-clamp and circulatory arrest times were, respectively, 96.5 ± 42.9, 21.1 ± 16.4 and 10.2 ± 8.2 min (mean temperature of 25.7 ± 4.9°C). Hepatic exclusion without the use of CPB was performed to excise the thrombus in 3 patients. A right nephrectomy was performed in 25 patients, a left in 15 patients and a bilateral nephrectomy in 1 patient. Five patients had a partial inferior vena cava (IVC) resection, with 4 patients requiring a patch reconstruction of the IVC. Three patients had an infrarenal IVC ligation. One patient suffered a cerebrovascular accident in the postoperative period. One in-hospital death occurred (in-hospital mortality 2.4%). The mean follow-up was 1.9 ± 2.0 years. Twenty-three patients died during follow-up; 21 were disease-related. Three-year survival rate was 37.1%. High-level RCC tumour thrombus is a rare clinical entity, the treatment of which is complex and requires dedicated operative teams. The operative technique should be tailored according to the level of extension and the extent of vena cava obstruction/occlusion of the tumour thrombus. Contemporary operative techniques may be conducted with excellent results. Mid-term survival is limited, supporting the necessity to pursue research efforts towards establishing effective adjunct therapies. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Iodine-125 Seeds Strand for Treatment of Tumor Thrombus in Inferior Vena Cava: An Experimental Study in a Rabbit Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Wen, E-mail: wenzhangxiao@126.com; Yan, Zhiping, E-mail: Yan.zhiping@zs-hospital.sh.cn; Luo, Jianjun, E-mail: luo.jianjun@zs-hospital.sh.cn

    Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy,more » and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model.« less

  20. Deep vein thrombus formation induced by flow reduction in mice is determined by venous side branches.

    PubMed

    Brandt, Moritz; Schönfelder, Tanja; Schwenk, Melanie; Becker, Christian; Jäckel, Sven; Reinhardt, Christoph; Stark, Konstantin; Massberg, Steffen; Münzel, Thomas; von Brühl, Marie-Luise; Wenzel, Philip

    2014-01-01

    Interaction between vascular wall abnormalities, inflammatory leukocytes, platelets, coagulation factors and hemorheology in the pathogenesis of deep vein thrombosis (DVT) is incompletely understood, requiring well defined animal models of human disease. We subjected male C57BL/6 mice to ligation of the inferior vena cava (IVC) as a flow reduction model to induce DVT. Thrombus size and weight were analyzed macroscopically and sonographically by B-mode, pulse wave (pw) Doppler and power Doppler imaging (PDI) using high frequency ultrasound. Thrombus size varied substantially between individual procedures and mice, irrespective of the flow reduction achieved by the ligature. Interestingly, PDI accurately predicted thrombus size in a very robust fashion (r2 = 0.9734, p < 0.0001). Distance of the insertion of side branches from the ligature significantly determines thrombus weight (r2 = 0.5597, p < 0.0001) and length (r2 = 0.5441, p < 0.0001) in the IVC, regardless of the flow measured by pw-Doppler with distances <1.5 mm drastically impairing thrombus formation. Occlusion of side branches prior to ligation of IVC did not increase thrombus size, probably due to patent side branches inaccessible to surgery. Venous side branches influence thrombus size in experimental DVT and might therefore prevent thrombus formation. This renders vessel anatomy and hemorheology important determinants in mouse models of DVT, which should be controlled for.

  1. A case report of metastatic neuroendocrine carcinoma of the right adrenal gland successfully treated with chemotherapy and surgery.

    PubMed

    Ochiai, Toshiya; Komiyama, Sosuke; Ikoma, Hisashi; Kubota, Takeshi; Nakanishi, Masayoshi; Ichikawa, Daisuke; Kikuchi, Shojiro; Fujiwara, Hitoshi; Sakakura, Chohei; Kokuba, Yukihito; Sonoyama, Teruhisa; Otsuji, Eigo

    2010-08-01

    Poorly differentiated neuroendocrine carcinoma has a poor prognosis, especially when associated with distant metastasis. A 60-year-old man was admitted to a private hospital because of dyspnea at work in 2007. Computed tomography revealed lung infarction and a right adrenal tumor sized 12 cm in diameter that was tightly compressed against the inferior vena cava (IVC). Moreover, multiple lymph node metastases around the celiac axis and a solitary liver metastasis at the lateral segment were observed. Thus, we planned chemotherapy without surgery. We selected a combination therapy of irinotecan (CPT-11) and cisplatin (CDDP) (i.e., IP therapy): administration of CDDP [60 mg/m(2) body surface area (BSA)] on day 1 plus CPT-11 (80 mg/m(2)) BSA on days 1 and 8. Thereafter, this protocol was repeated at 3-week intervals. After 15 months of this chemotherapy strategy, the whole lesions showed a partial response by RECIST. The primary tumor had shrunk to 4.2 cm in diameter. In November 2008, we planned surgery to perform resection of the whole lesions. Histological diagnosis of the specimen was a poorly differentiated neuroendocrine carcinoma based on the immunostaining features, i.e., synaptophysin- and chromogranin positive. There were no viable tumor cells at the dissected lymph nodes or at the liver tumor. After surgery, CPT-11 administration was continued. The patient has remained well for 9 months without recurrence.

  2. Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, Joshua D., E-mail: Joshua.Dowell@osumc.edu; Wagner, Daniel, E-mail: Daniel.Wagner@osumc.edu; Elliott, Eric, E-mail: Eric.Elliott@osumc.edu

    PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15more » females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.« less

  3. TACE Combined with Implantation of Irradiation Stent Versus TACE Combine with Bare Stent for HCC Complicated by IVCTT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin

    PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission ratemore » and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.« less

  4. Imaging Analysis of Hepatoblastoma Resectability Across Neoadjuvant Chemotherapy

    PubMed Central

    Murphy, Andrew J.; Ayers, Gregory D.; Hilmes, Melissa A.; Mukherjee, Kaushik; Wilson, Kevin J.; Allen, Wade M.; Fernandez-Pineda, Israel; Shinall, Myrick C.; Zhao, Zhiguo; Furman, Wayne L.; McCarville, Mary Beth; Davidoff, Andrew M.; Lovvorn, Harold N.

    2013-01-01

    Purpose Hepatoblastomas often require neoadjuvant chemotherapy to facilitate partial hepatectomy, which necessitates freedom of tumor borders from the confluence of hepatic veins (COHV), portal vein bifurcation (PVB), and retrohepatic inferior vena cava (IVC). This study aimed to clarify the effect of incremental neoadjuvant cycles on the AHEP0731 protocol criteria of hepatoblastoma resectability. Methods Hepatoblastoma responses to neoadjuvant chemotherapy were analyzed among patients (n=23) treated at two children’s hospitals between 1996 and 2010. Using digital imaging data, ellipsoid and point-based models were created to measure tumor volume regression and respective distances from tumor borders nearest to the COHV, PVB, and IVC. Results Hepatoblastoma volumes regressed with incremental neoadjuvant chemotherapy cycles (p<0.001). Although tumor borders regressed away from the COHV (p=0.008), on average only 1.1mm was gained. No change from tumor borders to the PVB was detected (p=0.102). Distances from tumor borders to the IVC remained stable at one hospital (p=0.612), but increased only 0.15mm every 10 days of therapy at the other (p=0.002). Neoadjuvant chemotherapy induced slightly more tumors to meet the threshold vascular margin of 1cm (baseline to completion): COHV, 11 (47.8%) to 17 (73.9%; p=0.058); PVB, 11 (47.8%) to 15 (65.2%; p=0.157); IVC, 4 (17.4%) to 10 (43.5%; p=0.034). No differences were detected in demographic or disease-specific characteristics between patients who did or did not achieve this 1cm margin after conclusion of chemotherapy. Conclusion Hepatoblastoma volumes regress significantly with increasing neoadjuvant chemotherapy cycles. However, tumors often remain anchored to the major hepatic vasculature, showing marginal improvement in resectability criteria. PMID:23845613

  5. Risk factors for and causes and treatment of recurrence of inferior vena cava type of Budd-Chiari syndrome after stenting in China: A retrospective analysis of a large cohort.

    PubMed

    Li, Wen-Dong; Yu, Hui-Ying; Qian, Ai-Min; Rong, Jian-Jie; Zhang, Ye-Qing; Li, Xiao-Qiang

    2017-03-01

    To explore the risk factors for recurrence of inferior vena cava (IVC)-type Budd-Chiari syndrome (BCS) after stenting and evaluate the feasibility and primary outcomes of endovascular therapies for recurrent BCS. A retrospective analysis of 219 patients was performed to identify risk factors for recurrence. The images of the recurrent patients during follow-up duration and interventional surgery were also reviewed to find the possible reasons of recurrence. The outcome of endovascular therapies for recurrent BCS was evaluated by Kaplan-Meier analysis. Among the 219 patients, 172 patients with primary IVC-type BCS underwent stenting and 28 patients experienced recurrence. Multivariate analysis identified age, Child-Pugh score, MELD and total bilirubin as independent recurrent indicators. Possible causes of recurrence include thrombosis in the stent, re-obstruction in or above the stent, and stent-related hepatic vein obstruction. Twenty-five patients with recurrent BCS underwent endovascular therapies with a few complications and achieved a high level of short- and mid-term patency. Age, total bilirubin and severity of liver function are the main risk factors for BCS recurrence. These risks might contribute to thrombosis or subsequent fibrous obstruction. Endovascular therapies are effective and safe management options that yield positive outcomes for recurrent BCS. • Risk factors for recurrent Budd-Chiari syndrome were identified by multivariate analysis. • Causes of recurrent Budd-Chiari syndrome were investigated by assessing radiological images. • There is a correlation between risk factors and causes of recurrence. • Endovascular therapies for recurrent Budd-Chiari syndrome are effective and safe.

  6. Indwelling and Retrieval Complications of Denali and Celect Infrarenal Vena Cava Filters.

    PubMed

    Bos, Aaron S; Tullius, Thomas; Patel, Mikin; Leef, Jeffrey A; Navuluri, Rakesh; Lorenz, Jonathan M; Van Ha, Thuong G

    2016-07-01

    To compare indwelling and retrieval complications of Denali and Celect filters placed in the infrarenal inferior vena cava (IVC). A retrospective study was conducted over 2 years at a single institution in which 171 Denali and 162 Celect filters were placed in 333 patients with a mean age of 62.3 years ± 15.7 (161 men; 48.3%). Filter indications included venous thromboembolic disease (n = 320; 96.1%) and surgical prophylaxis (n = 13; 3.9%). A jugular approach was used to place 303 filters (91.0%). Computed tomography (CT) follow-up, complications, and retrieval data were obtained. Follow-up CT imaging was performed on 58 filters from each group with lower incidences of caval strut penetration (one vs 12) and filter tilt (one vs 15) in the Denali filter group (P = .002 and P < .001, respectively). There was no difference in incidences of breakthrough pulmonary embolism (P = .68). Retrieval attempts were performed on 43 Denali and 53 Celect filters with mean indwelling times at retrieval of 128.2 and 144.1 days, respectively (P = .40). Mean fluoroscopy time at retrieval was lower in the Denali group (3.1 min vs 6.0 min; P = .01). There were fewer cases of complex retrieval in the Denali group (n = 2 vs 10; P = .06). Tilt, fluoroscopy time, and air kerma were associated with complex retrieval (P = .04, P < .001, and P < .001, respectively). There was one Denali filter deployment complication that led to retrieval failure. This study suggests that Denali filters are associated with lower incidences of strut penetration and filter tilt as well as shorter fluoroscopy time at retrieval compared with Celect filters when placed in the infrarenal IVC. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  7. Denali, Tulip, and Option Inferior Vena Cava Filter Retrieval: A Single Center Experience.

    PubMed

    Ramaswamy, Raja S; Jun, Emily; van Beek, Darren; Mani, Naganathan; Salter, Amber; Kim, Seung K; Akinwande, Olaguoke

    2018-04-01

    To compare the technical success of filter retrieval in Denali, Tulip, and Option inferior vena cava filters. A retrospective analysis of Denali, Gunther Tulip, and Option IVC filters was conducted. Retrieval failure rates, fluoroscopy time, sedation time, use of advanced retrieval techniques, and filter-related complications that led to retrieval failure were recorded. There were 107 Denali, 43 Option, and 39 Tulip filters deployed and removed with average dwell times of 93.5, 86.0, and 131 days, respectively. Retrieval failure rates were 0.9% for Denali, 11.6% for Option, and 5.1% for Tulip filters (Denali vs. Option p = 0.018; Denali vs. Tulip p = 0.159; Tulip vs. Option p = 0.045). Median fluoroscopy time for filter retrieval was 3.2 min for the Denali filter, 6.75 min for the Option filter, and 4.95 min for the Tulip filter (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p = 0.67). Advanced retrieval techniques were used in 0.9% of Denali filters, 21.1% in Option filters, and 10.8% in Tulip filters (Denali vs. Option p < 0.01; Denali vs. Tulip p < 0.01; Tulip vs. Option p < 0.01). Filter retrieval failure rates were significantly higher for the Option filter when compared to both the Denali and Tulip filters. Retrieval of the Denali filter required significantly less amount of fluoroscopy time and use of advanced retrieval techniques when compared to both the Option and Tulip filters. The findings of this study indicate easier retrieval of the Denali and Tulip IVC filters when compared to the Option filter.

  8. Evaluation of a Device Combining an Inferior Vena Cava Filter and a Central Venous Catheter for Preventing Pulmonary Embolism Among Critically Ill Trauma Patients.

    PubMed

    Tapson, Victor F; Hazelton, Joshua P; Myers, John; Robertson, Claudia; Gilani, Ramyar; Dunn, Julie A; Bukur, Marko; Croce, Martin A; Peick, Ann; West, Sonlee; Lottenberg, Lawrence; Doucet, Jay; Miller, Preston R; Crookes, Bruce; Gandhi, Rajesh R; Croft, Chasen A; Manasia, Anthony; Hoey, Brian A; Lieberman, Howard; Guillamondegui, Oscar D; Novack, Victor; Piazza, Gregory; Goldhaber, Samuel Z

    2017-09-01

    To evaluate efficacy and safety of a novel device that combines an inferior vena cava (IVC) filter and central venous catheter (CVC) for prevention of pulmonary embolism (PE) in critically ill patients. In a multicenter, prospective, single-arm clinical trial, the device was inserted at the bedside without fluoroscopy and subsequently retrieved before transfer from the intensive care unit (ICU). The primary efficacy endpoint was freedom from clinically significant PE or fatal PE 72 hours after device removal or discharge, whichever occurred first. Secondary endpoints were incidence of acute proximal deep venous thrombosis (DVT), catheter-related thrombosis, catheter-related bloodstream infections, major bleeding events, and clinically significant thrombus (occupying > 25% of volume of filter) detected by cavography before retrieval. The device was placed in 163 critically ill patients with contraindications to anticoagulation; 151 (93%) were critically ill trauma patients, 129 (85%) had head or spine trauma, and 102 (79%) had intracranial bleeding. The primary efficacy endpoint was achieved for all 163 (100%) patients (95% confidence interval [CI], 97.8%-100%, P < .01). Diagnosis of new or worsening acute proximal DVT was time dependent with 11 (7%) occurring during the first 7 days. There were no (0%) catheter-related bloodstream infections. There were 5 (3.1%) major bleeding events. Significant thrombus in the IVC filter occurred in 14 (8.6%) patients. Prophylactic anticoagulation was not initiated for a mean of 5.5 days ± 4.3 after ICU admission. This novel device prevented clinically significant and fatal PE among critically ill trauma patients with low risk of complications. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  9. A rare case of unprovoked venous thromboembolism manifestation in a young patient with antithrombin Type IIB deficiency combined with inferior vena cava anomaly from Lithuania.

    PubMed

    Saulytė-Trakymienė, Sonata; Adomaitienė, Irina; Unkrig, Susanne; Oldenburg, Johannes; Ivaškevičius, Vytautas

    2017-01-01

    Hereditary antithrombin (AT) deficiency is an autosomal-dominant disorder predisposing to venous and arterial thrombosis. Homozygosity resulting in severe AT deficiency is not compatible with life, apart from homozygous mutations affecting the heparin-binding site representing the most severe thrombophilia. A 12-year-old previously healthy boy of Romani origin presented with a swollen, painful left leg and fever. Imaging revealed signs of inferior vena cava (IVC) thrombosis, the presence of interrupted intrahepatic IVC with azygos continuation and bilateral iliofemoral thrombosis with enlargement of the azygous and hemiazygos venous system. In addition, right pleural effusion and signs of bilateral renal pericortical cysts, possibly caused by retroperitoneal lymphangiectasia, were disclosed. Thrombophilia screening involving protein C, Protein S, Antithrombin (chromogenic assays based on the inhibition of FIIa and FXa, antigen concentration), APC resistance, prothrombin mutation and Lupus anticoagulants was performed using standard laboratory methods. Genetic analysis of the SERPINC1 gene was done by direct sequencing. Thrombophilia screening showed isolated decreased AT activity at 21% (RR 80-120%). AT levels were retested and remained decreased (33-36%) on two consecutive occasions. SERPINC1 gene analysis revealed a previously described homozygous mutation (Budapest III) causing type IIB deficiency (c.391C>T; p.Leu131Phe). A family study confirmed the same mutation in both parents and three siblings. The patient improved significantly following warfarin therapy and over the past 2.5 years did not experience new thromboembolism. This case represents a rare combination of two risk factors provoking manifestation of spontaneous venous thromboembolism at a young age requiring permanent anticoagulant therapy. Schattauer GmbH.

  10. Common iliac vein stenosis and risk of symptomatic pulmonary embolism: an inverse correlation.

    PubMed

    Chan, Keith T; Popat, Rita A; Sze, Daniel Y; Kuo, William T; Kothary, Nishita; Louie, John D; Hovsepian, David M; Hwang, Gloria L; Hofmann, Lawrence V

    2011-02-01

    To test the hypothesis that a common iliac vein (CIV) stenosis may impair embolization of a large deep venous thrombosis (DVT) to the lungs, decreasing the incidence of a symptomatic pulmonary embolism (PE). Between January 2002 and August 2007, 75 patients diagnosed with unilateral DVT were included in a single-institution case-control study. Minimum CIV diameters were measured 1 cm below the inferior vena cava (IVC) bifurcation on computed tomography (CT) images. A significant stenosis in the CIV ipsilateral to the DVT was defined as having either a diameter 4 mm or less or a greater than 70% reduction in lumen diameter. A symptomatic PE was defined as having symptoms and imaging findings consistent with a PE. The odds of symptomatic PE versus CIV stenosis were assessed using logistic regression models. The associations between thrombus location, stenosis, and symptomatic PE were assessed using a stratified analysis. Of 75 subjects, 49 (65%) presented with symptomatic PE. There were 17 (23%) subjects with a venous lumen 4 mm or less and 12 (16%) subjects with a greater than 70% stenosis. CIV stenosis of 4 mm or less resulted in a decreased odds of a symptomatic PE compared with a lumen greater than 4 mm (odds ratio [OR] 0.17, P = .011), whereas a greater than 70% stenosis increased the odds of DVT involving the CIV (OR 7.1, P = .047). Among patients with unilateral DVT, those with an ipsilateral CIV lumen of 4 mm or less have an 83% lower risk of developing symptomatic PE compared with patients with a CIV lumen greater than 4 mm. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  11. Persistent left superior vena cava

    PubMed Central

    Tyrak, Kamil W; Hołda, Mateusz K; Koziej, Mateusz; Piątek, Katarzyna; Klimek-Piotrowska, Wiesława

    2017-01-01

    Summary Persistent left superior vena cava (PLSVC) is the most common congenital malformation of thoracic venous return and is present in 0.3 to 0.5% of individuals in the general population. This heart specimen was dissected from a 35-yearold male cadaver whose cause of death was determined as non-cardiac. The heart was examined and we found a PLSVC draining into the coronary sinus. The right superior vena cava was present with a small-diameter ostium. An anomalous pulmonary vein pattern was observed; there was a common trunk to the left superior and left inferior pulmonary veins (diameter 17.8 mm) and an additional middle right pulmonary vein (diameter 2.7 mm) with two classic right pulmonary veins. The PLSVC draining into the coronary sinus had led to its enlargement, which could have altered the cardiac haemodynamics by significantly reducing the size of the left atrium and impeding its outflow via the mitral valve. PMID:28759082

  12. Integrating bio-prosthetic valves in the Fontan operation - Novel treatment to control retrograde flow in caval veins

    NASA Astrophysics Data System (ADS)

    Vukicevic, Marija; Conover, Timothy; Zhou, Jian; Hsia, Tain-Yen; Figliola, Richard

    2012-11-01

    For a child born with only one functional heart ventricle, the sequence of palliative surgeries typically culminates in the Fontan operation. This procedure is usually successful initially, but leads to later complications, for reasons not fully understood. Examples are respiratory-dependent retrograde flows in the caval and hepatic veins, and increased pulmonary vascular resistance (PVR), hypothesized to be responsible for elevated pressure in the liver and disease of the liver and intestines. Here we study the parameters responsible for retrograde flows in the inferior vena cava (IVC) and hepatic vein (HV), and investigate two novel interventions to control retrograde flow: implanting either a Medtronic Contegra valved conduit or an Edwards lifescience pericardial aortic valve in the IVC or HV. We performed the experiments in a multi-scale, patient specific mock circuit, with normal and elevated PVR, towards the optimization of the Fontan circulation. The results show that both valves can significantly reduce retrograde flows in the veins, suggesting potential advantages in the treatment of the patients with congenital heart diseases. Fondation Leducq

  13. Prostaglandin E2 releases ovine fetal ACTH from a site not perfused by the carotid vasculature.

    PubMed

    Cudd, T A; Wood, C E

    1992-07-01

    Placental prostaglandin E2 (PGE2) is thought to influence the ovine fetal adrenocortical system to control the timing of parturition. We investigated whether physiological infusions of PGE2 increase fetal immunoreactive adrenocorticotropin (iACTH) at the fetal brain or pituitary or at a site not perfused by the carotid vasculature. PGE2 was infused into the carotid artery (ica) at 0 (n = 5), 10 (n = 5), or 100 ng/min (n = 4) or into the vena cava (ivc) at 10 (n = 5) or 100 ng/min (n = 5) for 30 min in fetuses between 119 and 130 days gestation. Blood gases, vasopressin, cortisol, and arterial and central venous pressure were unchanged. Heart rate increased only in the 100 ng/min ica group. iACTH increased only in the 100 ng/min ivc group from 59 +/- 26 to 180 +/- 73 pg/ml. We conclude that PGE2 infused to create physiological plasma concentrations similar to those at the end of gestation stimulates iACTH from a site other than the fetal brain or pituitary.

  14. Optimization of an idealized Y-Shaped Extracardiac Fontan Baffle

    NASA Astrophysics Data System (ADS)

    Yang, Weiguang; Feinstein, Jeffrey; Mohan Reddy, V.; Marsden, Alison

    2008-11-01

    Research has showed that vascular geometries can significantly impact hemodynamic performance, particularly in pediatric cardiology, where anatomy varies from one patient to another. In this study we optimize a newly proposed design for the Fontan procedure, a surgery used to treat single ventricle heart patients. The current Fontan procedure connects the inferior vena cava (IVC) to the pulmonary arteries (PA's) via a straight Gore-Tex tube, forming a T-shaped junction. In the Y-graft design, the IVC is connected to the left and right PAs by two branches. Initial studies on the Y-graft design showed an increase in efficiency and improvement in flow distribution compared to traditional designs in a single patient-specific model. We now optimize an idealized Y-graft model to refine the design prior to patient testing. A derivate-free optimization algorithm using Kriging surrogate functions and mesh adaptive direct search is coupled to a 3-D finite element Navier-Stokes solver. We will present optimization results for rest and exercise conditions and examine the influence of energy efficiency, wall shear stress, pulsatile flow, and flow distribution on the optimal design.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalva, Sanjeeva P., E-mail: skalva@partners.org; Athanasoulis, Christos A.; Fan, C.-M.

    The purpose of the study was to assess the clinical safety and efficacy of the 'Recovery{sup TM}' (Bard) inferior vena cava (IVC) filter. We retrospectively evaluated the clinical and imaging data of patients who had a 'Recovery{sup TM}' IVC filter placed between January 2003 and December 2004 in our institution. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. Follow-up computed tomography (CT) examinations of the abdomen and chest were evaluated for filter-related complications and pulmonary embolism (PE), respectively. 'Recovery' filters were placed in 96 patients (72 males and 24 females; age range: 16-87 years; mean:more » 46 years). Twenty-four patients presented with PE, 13 with deep vein thrombosis (DVT) and 2 with both PE and DVT. The remaining 57 patients had no symptoms of thromboembolism. Indications for filter placement included contraindication to anticoagulation (n = 27), complication of anticoagulation (n = 3), failure of anticoagulation (n = 5), and prophylaxis (n = 61). The device was successfully deployed in the infrarenal (n = 95) or suprarenal (n = 1) IVC through a femoral vein approach. Retrieval was attempted in 11 patients after a mean period of 117 days (range: 24-426). The filter was successfully removed in nine patients (82%). Failure of retrieval was due to technical difficulty (n = 1) and the presence of thrombus in the filter (n = 1). One of the nine patients who had the filter removed developed IVC thrombus after retrieval and another had an intimal tear of the IVC. Follow-up abdominal CT (n = 40) at a mean of 80 days (range: 1-513) showed penetration of the IVC by the filter arms in 11, of which 3 had fracture of filter components. In one patient, a broken arm migrated into the pancreas. Asymmetric deployment of the filter legs was seen in 12 patients and thrombus within the filter in 2 patients. No filter migration or caval occlusion was encountered. Follow-up chest CT (n = 27) at a mean of 63 days (range: 1-386) showed PE in one patient (3%). During clinical follow-up, 12 of 96 patients developed symptoms of PE and only 1 of the 12 had PE on CT. There was no fatal pulmonary embolism in our group of patients following 'Recovery' filter placement. However, the current version of the filter is associated with structure weakness, a high incidence of IVC wall penetration, and asymmetric deployment of the filter legs.« less

  16. The need for venovenous bypass in liver transplantation

    PubMed Central

    Fonouni*, Hamidreza; Soleimani, Mehrdad; Müller, Sascha A.; Büchler, Markus W.; Schmidt, Jan

    2008-01-01

    Since introduction of the conventional liver transplantation (CLTx) by Starzl, which was based on the resection of recipient inferior vena cava (IVC) along the liver, the procedure has undergone several refinements. Successful use of venovenous bypass (VVB) was first introduced by Shaw et al., although in recent decades there has been controversy regarding the routine use of VVB during CLTx. With development of piggyback liver transplantation (PLTx), the use of caval clamping and VVB is avoided, leading to fewer complications related to VVB. However, some authors still advocate VVB in PLTx. The great diversity among centers in their use of VVB during CLTx, or even along the PLTx technique, has led to confusion regarding the indication setting for VVB. For this reason, we present an overview of the use of VVB in CLTx, the target of patients for whom VVB could be beneficial, and the needs assessment of VVB for patients undergoing PLTx. Recent studies have shown that with the advancement of surgical skills, refinement of surgical techniques, and improvements in anesthesiology, there are only limited indications for doing CLTx with VVB routinely. PLTx with preservation of IVC can be performed in almost all primary transplants and in the majority of re-transplantations without the need for VVB. Nevertheless, in a few selective cases with severe intra-operative hemodynamic instability, or with a failed test of transient IVC occlusion, the application of VVB is still justifiable. These indications should be judged intra-operatively and the decision is based on each center's preference. PMID:18773054

  17. Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea.

    PubMed

    Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni

    2017-06-19

    The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.

  18. Prospective implementation of an algorithm for bedside intravascular ultrasound-guided filter placement in critically ill patients.

    PubMed

    Killingsworth, Christopher D; Taylor, Steven M; Patterson, Mark A; Weinberg, Jordan A; McGwin, Gerald; Melton, Sherry M; Reiff, Donald A; Kerby, Jeffrey D; Rue, Loring W; Jordan, William D; Passman, Marc A

    2010-05-01

    Although contrast venography is the standard imaging method for inferior vena cava (IVC) filter insertion, intravascular ultrasound (IVUS) imaging is a safe and effective option that allows for bedside filter placement and is especially advantageous for immobilized critically ill patients by limiting resource use, risk of transportation, and cost. This study reviewed the effectiveness of a prospectively implemented algorithm for IVUS-guided IVC filter placement in this high-risk population. Current evidence-based guidelines were used to create a clinical decision algorithm for IVUS-guided IVC filter placement in critically ill patients. After a defined lead-in phase to allow dissemination of techniques, the algorithm was prospectively implemented on January 1, 2008. Data were collected for 1 year using accepted reporting standards and a quality assurance review performed based on intent-to-treat at 6, 12, and 18 months. As defined in the prospectively implemented algorithm, 109 patients met criteria for IVUS-directed bedside IVC filter placement. Technical feasibility was 98.1%. Only 2 patients had inadequate IVUS visualization for bedside filter placement and required subsequent placement in the endovascular suite. Technical success, defined as proper deployment in an infrarenal position, was achieved in 104 of the remaining 107 patients (97.2%). The filter was permanent in 21 (19.6%) and retrievable in 86 (80.3%). The single-puncture technique was used in 101 (94.4%), with additional dual access required in 6 (5.6%). Periprocedural complications were rare but included malpositioning requiring retrieval and repositioning in three patients, filter tilt >/=15 degrees in two, and arteriovenous fistula in one. The 30-day mortality rate for the bedside group was 5.5%, with no filter-related deaths. Successful placement of IVC filters using IVUS-guided imaging at the bedside in critically ill patients can be established through an evidence-based prospectively implemented algorithm, thereby limiting the need for transport in this high-risk population. Copyright (c) 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  19. Intra-abdominal primary monophasic synovial sarcoma with hemangiopericytoma-like areas.

    PubMed

    Rao, Lakshmi; Jaiprakash, Padmapriya; Palankar, Nagaraj; Gowda, Vinay

    2013-01-01

    We report a case of retroperitoneal intra-abdominal primary monophasic synovial sarcoma (SS) with hemangiopericytomatous (HPC) pattern in a 25-year-old male arising from the triangular ligament on the superior surface of liver encasing the inferior vena cava (IVC) and masquerading as a hepatic tumor. A large heterogeneously enhancing, well defined, lobulated, exophytic lesion was seen involving segment VIII of the liver with foci of calcification in the periphery. A biopsy, followed by total resection of the tumor, showed a spindle cell sarcoma with HPC pattern, which was consistent with monophasic SS on histology and immunohistochemistry. The unusual clinical presentation, radiology, pathology, and differential diagnosis will be discussed in detail.

  20. Advanced imaging in acute and chronic deep vein thrombosis

    PubMed Central

    Karande, Gita Yashwantrao; Sanchez, Yadiel; Baliyan, Vinit; Mishra, Vishala; Ganguli, Suvranu; Prabhakar, Anand M.

    2016-01-01

    Deep venous thrombosis (DVT) affecting the extremities is a common clinical problem. Prompt imaging aids in rapid diagnosis and adequate treatment. While ultrasound (US) remains the workhorse of detection of extremity venous thrombosis, CT and MRI are commonly used as the problem-solving tools either to visualize the thrombosis in central veins like superior or inferior vena cava (IVC) or to test for the presence of complications like pulmonary embolism (PE). The cross-sectional modalities also offer improved visualization of venous collaterals. The purpose of this article is to review the established modalities used for characterization and diagnosis of DVT, and further explore promising innovations and recent advances in this field. PMID:28123971

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abboud, Georges, E-mail: drgeorgesabboud@hotmail.com; Midulla, Marco, E-mail: marcomidu@gmail.com; Lions, Christophe, E-mail: c-lions@chru-lille.fr

    The May-Thurner syndrome is a well-known anatomical anomaly where the left common iliac vein (LCIV) is compressed between the right common iliac artery and the fifth vertebral body. This report describes the case of a 'right-sided' May-Thurner syndrome where the right common iliac vein (RCIV) is compressed by the left common iliac artery in a patient with a left-sided inferior vena cava (IVC). A 26-year-old woman was admitted to our institution with acute edema of the right lower limb. The diagnosis of May-Thurner syndrome was done by CT scan and confirmed by phlebography. An endovascular treatment with stenting was carriedmore » out, with good patency and clinical result at 12-month follow-up.« less

  2. Successful transcatheter occlusion of an anomalous pulmonary vein with dual drainage to the left atrium.

    PubMed

    Wilson, W; Horlick, E; Benson, L

    2015-06-01

    We describe a case of a scimitar syndrome "variant" where dual drainage existed from the right upper and middle pulmonary veins to the inferior vena cava and left atrium. Device closure of the anomalous vein at the level of the connection to the IVC was successful in achieving diversion of pulmonary venous flow to the left atrium. Vigilance during work-up of anomalous pulmonary venous drainage (whether isolated or associated with other cardiac defects that may be amenable to device closure) is important to define the presence of dual connections to the left atrium, in which case a less-invasive transcatheter approach may be feasible. © 2015 Wiley Periodicals, Inc.

  3. A review of the anatomy and clinical significance of adrenal veins.

    PubMed

    Cesmebasi, Alper; Du Plessis, Maira; Iannatuono, Mark; Shah, Sameer; Tubbs, R Shane; Loukas, Marios

    2014-11-01

    The adrenal veins may present with a multitude of anatomical variants, which surgeons must be aware of when performing adrenalectomies. The adrenal veins originate during the formation of the prerenal inferior vena cava (IVC) and are remnants of the caudal portion of the subcardinal veins, cranial to the subcardinal sinus in the embryo. The many communications between the posterior cardinal, supracardinal, and subcardinal veins of the primordial venous system provide an explanation for the variable anatomy. Most commonly, one central vein drains each adrenal gland. The long left adrenal vein joins the inferior phrenic vein and drains into the left renal vein, while the short right adrenal vein drains immediately into the IVC. Multiple variations exist bilaterally and may pose the risk of surgical complications. Due to the potential for collaterals and accessory adrenal vessels, great caution must be taken during an adrenalectomy. Adrenal venous sampling, the gold standard in diagnosing primary hyperaldosteronism, also requires the clinician to have a thorough knowledge of the adrenal vein anatomy to avoid iatrogenic injury. The adrenal vein acts as an important conduit in portosystemic shunts, thus the nature of the anatomy and hypercoagulable states pose the risk of thrombosis. © 2014 Wiley Periodicals, Inc.

  4. An outcome survey of 43 patients with Budd-Chiari syndrome due to Behçet's syndrome followed up at a single, dedicated center.

    PubMed

    Seyahi, Emire; Caglar, Erkan; Ugurlu, Serdal; Kantarci, Fatih; Hamuryudan, Vedat; Sonsuz, Abdullah; Melikoglu, Melike; Yurdakul, Sebahattin; Yazici, Hasan

    2015-04-01

    Behçet's syndrome (BS) is a well-recognized cause of Budd-Chiari syndrome (BCS); however, information about its clinical characteristics and outcome is limited. We reviewed the records of about 9000 patients with BS registered at the multidisciplinary Behçet's syndrome outpatient clinic at Cerrahpasa Medical Faculty between July 1977 and October 2013. We identified 43 (40 M/3 F) patients who were diagnosed as having BCS. Their outcome was evaluated between September 2012 and October 2013. In total, 33 patients (77%) had presented with liver-related symptoms (Group I), while 10 (23%) were asymptomatic for liver disease (Group II). This latter group had presented with symptoms related to the presence of major vessel disease such as fever, leg swelling, or dyspnea. The site of venous obstruction determined in 41 patients was inferior vena cava (IVC) and hepatic veins combined in 25 (61%), IVC alone in 12 (29%), and only hepatic veins in 4 patients (10%). The number of patients with concurrent obstruction in the hepatic veins and the IVC was less in Group II than in Group I (3/10 vs 22/31, p = 0.06). A total of 20 (19 M/1 F) patients (47%) had died at a median of 10 months after diagnosis. Mortality was significantly lower in Group II (10%) than in Group I (58%), (p = 0.011). By the end of the survey, 23 patients were alive, of whom 21 could be re-evaluated at the clinic. BCS associated with BS is usually due to IVC thrombosis with or without hepatic vein thrombosis. Silent cases exist and have a better prognosis. The mortality rate among the patients symptomatic for liver disease remains high. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Anatomic variations of the renal vessels pertinent to transperitoneal vascular control in the management of trauma.

    PubMed

    Kaneko, Naoyuki; Kobayashi, Yasushi; Okada, Yoshiaki

    2008-05-01

    Operative exposure and control of the renal vessels through a transabdominal retroperitoneal (TARP) approach has been advocated for emergency management of renal trauma. The pertinent anatomic variations of the renal vasculature have not been well described. In 190 cadavers, the renal vessels were examined. The first 20 cadavers were examined via TARP approach, and 170 cadavers were investigated after evisceration. The findings were interpreted as they might relate to the TARP approach to the renal pedicle. The renal artery (RA) originated dorsally or inferiorly to the left renal vein (RV) in 70% of the cadavers on each side. Additional RAs emerging below the inferior mesenteric artery were present in 2.4% of cadavers on the right side and 1.8% on the left. Approach to the inferior vena cava (IVC) adequate for the management of trauma through the TARP approach was impossible, although it has been recommended in some research. The clinically significant incidence of variations was as follows: 47% multiple RAs, 13% multiple RVs, and 50% of at least 1 RA that coursed superior to the right RV on the right margin of the IVC. Knowledge of the varied anatomy of the renal vessels facilitates a safe approach to the kidneys in trauma management. The varied and unpredictable anatomy of the renal vasculature requires prompt change when the TARP approach fails to provide access to the vessels. In such cases, the colon should be mobilized promptly. On the right side of the IVC, the vessels are located so as to require clamping together almost always.

  6. Neutrophil extracellular traps promote deep vein thrombosis in mice

    PubMed Central

    Brill, A.; Fuchs, T.A.; Savchenko, A.S.; Thomas, G.M.; Martinod, K.; De Meyer, S.F.; Bhandari, A.A.; Wagner, D.D.

    2011-01-01

    Summary Background Upon activation, neutrophils can release nuclear material known as neutrophil extracellular traps (NETs), which were initially described as a part of antimicrobial defense. Extracellular chromatin was recently reported to be pro-thrombotic in vitro and to accumulate in plasma and thrombi of baboons with experimental deep vein thrombosis (DVT). Objective To explore the source and role of extracellular chromatin in DVT. Methods We used an established murine model of DVT induced by flow restriction (stenosis) in the inferior vena cava (IVC). Results We demonstrate that the levels of extracellular DNA increase in plasma after 6 h IVC stenosis, compared to sham-operated mice. Immunohistochemical staining revealed the presence of Gr-1-positive neutrophils in both red (RBC-rich) and white (platelet-rich) parts of thrombi. Citrullinated histone H3 (CitH3), an element of NETs’ structure, was present only in the red part of thrombi and was frequently associated with the Gr-1 antigen. Immunofluorescent staining of thrombi showed proximity of extracellular CitH3 and von Willebrand factor (VWF), a platelet adhesion molecule crucial for thrombus development in this model. Infusion of Deoxyribonuclease 1 (DNase 1) protected mice from DVT after 6 h and also 48 h IVC stenosis. Infusion of an unfractionated mixture of calf thymus histones increased plasma VWF and promoted DVT early after stenosis application. Conclusions Extracellular chromatin, likely originating from neutrophils, is a structural part of a venous thrombus and both the DNA scaffold and histones appear to contribute to the pathogenesis of DVT in mice. NETs may provide new targets for DVT drug development. PMID:22044575

  7. Contralateral Deep Vein Thrombosis after Iliac Vein Stent Placement in Patients with May-Thurner Syndrome.

    PubMed

    Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu

    2018-04-25

    To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P < .001). The primary patency rate of the contralateral CIV stent was 70% at 20 months. Contralateral DVT after CIV stent implantation has a relatively high incidence and often occurs late during follow-up. Overextension of the CIV stent to the IVC is associated with development of contralateral DVT, and VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.

  8. Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.

    PubMed

    Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech

    2016-06-01

    Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.

  9. Shunt diameter in agenesis of the ductus venosus with extrahepatic portosystemic shunt impacts on prognosis.

    PubMed

    Shen, O; Valsky, D V; Messing, B; Cohen, S M; Lipschuetz, M; Yagel, S

    2011-02-01

    Agenesis of the ductus venosus (ADV) is a rare condition in which there are two variants of umbilical vein drainage: intrahepatic shunt or extrahepatic (portosystemic) shunt. It has been posited that the extrahepatic variant carries a poorer prognosis. However, in the absence of associated anomalies there is still a wide variation in outcome. We evaluated the portal system in cases of ADV and aimed to identify parameters that might predict outcome. We conducted a retrospective study of cases of ADV with extrahepatic shunt that had been examined in two centers, and collected new cases prospectively. The route of the shunt was depicted using two-dimensional (2D) and three-dimensional (3D) ultrasound imaging. In an attempt to characterize portal system and shunt developmental variations and their possible impact on outcome, the diameter of the shunt was compared with the diameter of the umbilical vein and the entire portal vasculature was assessed. Poor outcome was defined as persistent morbidity or fetal or neonatal death. Twenty-two cases of ADV were identified: nine retrospectively and 13 prospectively. Aberrant shunts from the umbilical vein were identified to the right atrium, coronary sinus, inferior vena cava (IVC) and iliac vein. In seven of 22 cases (32%) a wide connection was observed. In six of these seven cases (86%) the outcome was poor, including four with severe associated anomalies and two with hepatic dysfunction. In five of these cases, cardiomegaly with tricuspid regurgitation was observed, as well as underdevelopment of the portal system. In only five of 15 cases with a narrow shunt (33%) was the outcome poor, and in all five cases the poor outcome was related to associated anomalies. In cases of ADV with extrahepatic shunt, portal system development is impacted by the diameter of the shunt. If the shunt is narrow, the portal system will have developed normally. A wide shunt is associated with underdevelopment or absence of the portal system. In cases of ADV with extrahepatic shunt, prognosis is determined by the severity of associated anomalies, the diameter of the shunt and development of the portal system. Copyright © 2010 ISUOG. Published by John Wiley & Sons, Ltd.

  10. Systemic venous anomalies in the Middle East

    PubMed Central

    Corno, Antonio F.; Alahdal, Sami A.; Das, Karuna Moy

    2013-01-01

    Introduction: Systemic venous anomalies are quite rare and can be associated with congenital heart disease requiring surgery. Materials and Methods: All consecutive patients (pts) undergoing surgery for congenital heart defects were retrospectively analyzed for presence of systemic venous anomalies: (a) Persistent left superior vena cava (PLSVC)(b) Inferior vena cava (IVC) interruption(c) Retro-aortic innominate vein Results: From 9/2010 to 5/2012 155 pts, median age 7 months, mean age 1.3 years (3 days–50 years), median weight 4 kg, mean weight 7.2 kg (0.6–110 kg) underwent congenital heart surgery. Twenty-nine systemic venous anomalies were identified in 28/155 patients (=18.1%). PLSVC was present in 21 pts (=13.5%), median age 4 months, mean age 2.7 years (3 days–22 years), median weight 6 kg, mean weight 10.1 kg (2.4–43.0 kg). IVC interruption was identified in 5 pts (=3.2%), median age 2 months, mean age 5.4 years (30 days–26 years), median weight 3.7 kg, median weight 17 kg (2.3–68.0 kg). Retro-aortic innominate vein was diagnosed in 3 pts (=1.9%), median age 5 years, mean age 3.7 years (10 months–5 years), median weight 12 kg, mean weight 10.1 kg (4.5–14 kg). Complete pre-operative diagnosis was obtained in 14/28 (=50%) pts with echocardiography and in other 8/28 (=28.6%) only after computed tomography (CT) scan, for a total of 22/28 (=78.6%) correct pre-operative diagnosis. In 6/28 (=21.4%) patients the diagnosis was intra-operative. Total incidence of systemic venous anomalies was 18.1% (vs. 4% in the literature, P = 0.0009), with presence of PLSVC = 13.5% (vs. 0.3–4.0%, respectively P = 0.0004 and P = 0.0012), IVC interruption = 3.2% (vs. 0.1–1.3%, N.S.), and retro-aortic innominate vein = 1.9% (vs. 0.2–1%, N.S.). Conclusions: Our study showed an incidence of systemic venous anomalies in Middle Eastern pts with congenital heart defects higher than previously reported. In 78.6% of pts the diagnosis was correctly made before surgery (echocardiography or CT scan), with 21.4% of complete diagnosis made at surgery. A careful pre-operative screening should be performed in all pts with congenital heart defects from this region to better identify all systemic venous anomalies for a more accurate surgical planning. PMID:24400249

  11. Use of Retrievable Compared to Permanent Inferior Vena Cava Filters: A Single-Institution Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ha, Thuong G. Van; Chien, Andy S.; Funaki, Brian S.

    The purpose of this study was to review the use, safety, and efficacy of retrievable inferior vena cava (IVC) filters in their first 5 years of availability at our institution. Comparison was made with permanent filters placed in the same period. A retrospective review of IVC filter implantations was performed from September, 1999, to September, 2004, in our department. These included both retrievable and permanent filters. The Recovery nitinol and Guenther tulip filters were used as retrievable filters. The frequency of retrievable filter used was calculated. Clinical data and technical data related to filter placement were reviewed. Outcomes, including pulmonarymore » embolism, complications associated with placement, retrieval, or indwelling, were calculated. During the study period, 604 IVC filters were placed. Of these, 97 retrievable filters (16%) were placed in 96 patients. There were 53 Recovery filter and 44 Tulip filter insertions. Subjects were 59 women and 37 men; the mean age was 52 years, with a range of from 18 to 97 years. The placement of retrievable filters increased from 2% in year 1 to 32% in year 5 of the study period. The total implantation time for the permanent group was 145,450 days, with an average of 288 days (range, 33-1811 days). For the retrievable group, the total implantation time was 21,671 days, with an average of 226 days (range, 2-1217 days). Of 29 patients who returned for filter retrieval, the filter was successfully removed in 28. There were 14 of 14 successful Tulip filter retrievals and 14 of 15 successful Recovery filter retrievals. In one patient, after an indwelling period of 39 days, a Recovery nitinol filter could not be removed secondary to a large clot burden within the filter. For the filters that were removed, the mean dwell time was 50 days for the Tulip type and 20 days for the Recovery type. Over the follow-up period there was an overall PE incidence of 1.4% for the permanent group and 1% for the retrieval group. In conclusion, there was an increase in the use of retrievable filters over the study period and an overall increase in the total number of filters implanted. The increased use of these filters appeared to be due to expanded indications predicated by their retrievability. Placement and retrieval of these filters have a low risk of complications, and retrievable filters appeared effective, as there was low rate of clinically significant pulmonary embolism associated with these filters during their indwelling time.« less

  12. Scimitar Syndrome and H-type Tracheo-esophageal Fistula in a Newborn Infant.

    PubMed

    Lastinger, Allison; El Yaman, Malek; Gustafson, Robert; Yossuck, Panitan

    2016-06-01

    Scimitar syndrome is a rare congenital anomaly characterized by partial anomalous pulmonary venous drainage of the right lung to the inferior vena cava (IVC) creating a tubular opacity paralleling the right cardiac border on chest radiography which resembles a curved Turkish sword or scimitar. Associated pulmonary and vascular anomalies have been reported in cases of Scimitar syndrome, most commonly hypoplasia of right lung, dextroposition of the heart, hypoplasia of the right pulmonary artery, and aberrant arterial supply from the descending aorta to the affected lobe of the right lung. To the best of our knowledge, this is the first case of Scimitar syndrome with an H-type tracheoesophageal fistula that has ever been reported. Copyright © 2013. Published by Elsevier B.V.

  13. Simulation-Based Laparoscopic Surgery Crisis Resource Management Training-Predicting Technical and Nontechnical Skills.

    PubMed

    Goldenberg, Mitchell G; Fok, Kai H; Ordon, Michael; Pace, Kenneth T; Lee, Jason Y

    2017-12-19

    To develop a unique simulation-based assessment using a laparoscopic inferior vena cava (IVC) injury scenario that allows for the safe assessment of urology resident's technical and nontechnical skills, and investigate the effect of personality traits performance in a surgical crisis. Urology residents from our institution were recruited to participate in a simulation-based training laparoscopic nephrectomy exercise. Residents completed demographic and multidimensional personality questionnaires and were instructed to play the role of staff urologist. A vasovagal response to pneumoperitoneum and an IVC injury event were scripted into the scenario. Technical and nontechnical skills were assessed by expert laparoscopic surgeons using validated tools (task checklist, GOALS, and NOTSS). Ten junior and five senior urology residents participated. Five residents were unable to complete the exercise safely. Senior residents outperformed juniors on technical (checklist score 15.1 vs 9.9, p < 0.01, GOALS score 18.0 vs 13.3, p < 0.01) and nontechnical performance (NOTSS score 13.8 vs 10.1, p = 0.03). Technical performance scores correlated with NOTSS scores (p < 0.01) and pass/fail rating correlated with technical performance (p < 0.01 for both checklist and GOALS), NOTSS score (p = 0.02), and blood loss (p < 0.01). Only the conscientiousness dimension of the big five inventory correlated with technical score (p = 0.03) and pass/fail rating (p = 0.04). Resident level of training and laparoscopic experience correlated with technical performance during a simulation-based laparoscopic IVC injury crisis management scenario, as well as multiple domains of nontechnical performance. Personality traits of our surgical residents are similar and did not predict technical skill. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. The utility of CT for predicting bile leaks in hepatic trauma.

    PubMed

    LeBedis, Christina A; Anderson, Stephan W; Mercier, Gustavo; Kussman, Steven; Coleman, Stephanie L; Golden, Louis; Penn, David R; Uyeda, Jennifer W; Soto, Jorge A

    2015-04-01

    The purpose of this study was to determine the efficacy of CT to predict the development of bile leaks in hepatic trauma. This HIPAA-compliant retrospective study was IRB approved and consent was waived. All patients who sustained hepatic trauma between January 1, 2006, and January 31, 2012, and who underwent CT and hepatobiliary scans during the same hospital admission were included. One hundred and thirty-two patients met the inclusion criteria. Comparison between the presence of biliary injury relative to American Association for the Surgery of Trauma (AAST) hepatic injury grade and mean distance of the hepatic laceration to the inferior vena cava (IVC) was made. The ability of free fluid to predict bile injury was analyzed. Forty-one (31 %) of the 132 patients had positive hepatobiliary scans. Of these 41 patients, seven (17 %) sustained low-grade and 34 (83 %) sustained high-grade hepatic injury compared with the 37 (41 %) low-grade and 54 (59 %) high-grade hepatic injuries in the negative hepatobiliary scan group. The mean distance to the IVC was 2.4 cm (SD 2.9 cm) and 3.6 cm (SD 3.3 cm) in patients with and without bile leaks, respectively. A statistically significant difference in the proportion of high-grade injuries and the mean distance from the IVC between the two groups was identified. The presence of free fluid on CT is sensitive, but not specific, for detecting a bile leak. CT findings, including AAST liver injury grade and location of the liver laceration, are able to predict which patients are at risk for developing bile leaks as seen on hepatobiliary scintigraphy, whereas the presence of free fluid is not.

  15. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach.

    PubMed

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-12-01

    To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17-73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections.

  16. Sinus venosus syndrome: atrial septal defect or anomalous venous connection? A multiplane transoesophageal approach

    PubMed Central

    Oliver, J M; Gallego, P; Gonzalez, A; Dominguez, F J; Aroca, A; Mesa, J M

    2002-01-01

    Objective: To discuss the anatomical features of sinus venosus atrial defect on the basis of a comprehensive transoesophageal echocardiography (TOE) examination and its relation to surgical data. Methods: 24 patients (13 men, 11 women, mean (SD) age 37 (17) years, range 17–73 years) with a posterior interatrial communication closely related to the entrance of the superior (SVC) or inferior vena cava (IVC) who underwent TOE before surgical repair. Records of these patients were retrospectively reviewed and compared with surgical assessments. Results: In 13 patients, TOE showed a deficiency in the extraseptal wall that normally separates the left atrium and right upper pulmonary vein from the SVC and right atrium. This deficiency unroofed the right upper pulmonary vein, compelling it to drain into the SVC, which overrode the intact atrial septum. In three patients, TOE examination showed a defect in the wall of the IVC, which continued directly into the posterior border of the left atrium. Thus, the intact muscular border of the atrial septum was overridden by the mouth of the IVC, which presented a biatrial connection. In the remaining eight patients, the defect was located in the muscular posterior border of the fossa ovalis. A residuum of atrial septum was visualised in the superior margin of the defect. Neither caval vein overriding nor anomalous pulmonary vein drainage was present. Conclusions: Sinus venosus syndrome should be regarded as an anomalous venous connection with an interatrial communication outside the confines of the atrial septum, in the unfolding wall that normally separates the left atrium from either caval vein. It results in overriding of the caval veins across the intact atrial septum and partial pulmonary vein anomalous drainage. It should be differentiated from posterior atrial septal defect without overriding or anomalous venous connections. PMID:12433899

  17. Iliocaval Confluence Stenting for Chronic Venous Obstructions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graaf, Rick de, E-mail: r.de.graaf@mumc.nl; Wolf, Mark de, E-mail: markthewolf@gmail.com; Sailer, Anna M., E-mail: anni.sailer@mumc.nl

    PurposeDifferent techniques have been described for stenting of venous obstructions. We report our experience with two different confluence stenting techniques to treat chronic bi-iliocaval obstructions.Materials and MethodsBetween 11/2009 and 08/2014 we treated 40 patients for chronic total bi-iliocaval obstructions. Pre-operative magnetic resonance venography showed bilateral extensive post-thrombotic scarring in common and external iliac veins as well as obstruction of the inferior vena cava (IVC). Stenting of the IVC was performed with large self-expandable stents down to the level of the iliocaval confluence. To bridge the confluence, either self-expandable stents were placed inside the IVC stent (24 patients, SECS group) ormore » high radial force balloon-expandable stents were placed at the same level (16 patients, BECS group). In both cases, bilateral iliac extensions were performed using nitinol stents.ResultsRecanalization was achieved for all patients. In 15 (38 %) patients, a hybrid procedure with endophlebectomy and arteriovenous fistula creation needed to be performed because of significant involvement of inflow vessels below the inguinal ligament. Mean follow-up was 443 ± 438 days (range 7–1683 days). For all patients, primary, assisted-primary, and secondary patency rate at 36 months were 70, 73, and 78 %, respectively. Twelve-month patency rates in the SECS group were 85, 85, and 95 % for primary, assisted-primary, and secondary patency. In the BECS group, primary patency was 100 % during a mean follow-up period of 134 ± 118 (range 29–337) days.ConclusionStenting of chronic bi-iliocaval obstruction shows relatively high patency rates at medium follow-up. Short-term patency seems to favor confluence stenting with balloon-expandable stents.« less

  18. Ultrasound Findings in Tension Pneumothorax: A Case Report.

    PubMed

    Inocencio, Maxine; Childs, Jeannine; Chilstrom, Mikaela L; Berona, Kristin

    2017-06-01

    Delayed recognition of tension pneumothorax can lead to a mortality of 31% to 91%. However, the classic physical examination findings of tracheal deviation and distended neck veins are poorly sensitive in the diagnosis of tension pneumothorax. Point-of-care ultrasound is accurate in identifying the presence of pneumothorax, but sonographic findings of tension pneumothorax are less well described. We report the case of a 21-year-old man with sudden-onset left-sided chest pain. He was clinically stable without hypoxia or hypotension, and the initial chest x-ray study showed a large pneumothorax without mediastinal shift. While the patient was awaiting tube thoracostomy, a point-of-care ultrasound demonstrated findings of mediastinal shift and a dilated inferior vena cava (IVC) concerning for tension physiology, even though the patient remained hemodynamically stable. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: This case demonstrates a unique clinical scenario of ultrasound evidence of tension physiology in a clinically stable patient. Although this patient was well appearing without hypotension, respiratory distress, tracheal deviation, or distended neck veins, point-of-care ultrasound revealed mediastinal shift and a plethoric IVC. Given that the classic clinical signs of tension pneumothorax are not uniformly present, this case shows how point-of-care ultrasound may diagnose tension pneumothorax before clinical decompensation. Published by Elsevier Inc.

  19. Automatic blood vessel based-liver segmentation using the portal phase abdominal CT

    NASA Astrophysics Data System (ADS)

    Maklad, Ahmed S.; Matsuhiro, Mikio; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Shimada, Mitsuo; Iinuma, Gen

    2018-02-01

    Liver segmentation is the basis for computer-based planning of hepatic surgical interventions. In diagnosis and analysis of hepatic diseases and surgery planning, automatic segmentation of liver has high importance. Blood vessel (BV) has showed high performance at liver segmentation. In our previous work, we developed a semi-automatic method that segments the liver through the portal phase abdominal CT images in two stages. First stage was interactive segmentation of abdominal blood vessels (ABVs) and subsequent classification into hepatic (HBVs) and non-hepatic (non-HBVs). This stage had 5 interactions that include selective threshold for bone segmentation, selecting two seed points for kidneys segmentation, selection of inferior vena cava (IVC) entrance for starting ABVs segmentation, identification of the portal vein (PV) entrance to the liver and the IVC-exit for classifying HBVs from other ABVs (non-HBVs). Second stage is automatic segmentation of the liver based on segmented ABVs as described in [4]. For full automation of our method we developed a method [5] that segments ABVs automatically tackling the first three interactions. In this paper, we propose full automation of classifying ABVs into HBVs and non- HBVs and consequently full automation of liver segmentation that we proposed in [4]. Results illustrate that the method is effective at segmentation of the liver through the portal abdominal CT images.

  20. In Vitro Evaluation of a Rheolytic Thrombectomy System for Clot Removal from Five Different Temporary Vena Cava Filters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buecker, Arno; Neuerburg, Joerg; Schmitz-Rode, Thomas

    1997-11-15

    Purpose: To evaluate the feasibility of thrombus removal from temporary vena cava filters using a rheolytic thrombectomy device and to assess the embolization rate of this procedure. Methods: Five temporary vena cava filters together with porcine thrombi were placed in a vena cava flow model (semitranslucent silicone tube of 23 mm diameter, pulsatile flow at a mean flow rate of 4 L/min). A rheolytic thrombectomy system (Hydrolyser) was used with a 9 Fr guiding catheter to remove the clots. The effluent was passed through filters of different size and the amount of embolized particles as well as the remaining thrombusmore » were measured. Results: Thrombus removal rates ranged from 85% to 100%. Embolization rates between 47% and 60% were calculated for the different filters. Conclusion: The Hydrolyser is able to remove sufficiently high amounts of thrombus from temporary vena cava filters. However, the amount of embolized particles makes it impossible to utilize this method without special precautions against embolization.« less

  1. Reversed differential cyanosis in the newborn: a clinical finding in the supracardiac total anomalous pulmonary venous connection.

    PubMed

    Yap, Shook H; Anania, Nicole; Alboliras, Ernerio T; Lilien, Lawrence D

    2009-04-01

    The newborn can experience two types of differential cyanosis (DC). The common type of DC occurs when oxygen saturation in the right hand is greater than in the foot. The second type of DC, reversed differential cyanosis (RDC), occurs when oxygen saturation is lower in the right hand than in the foot. This phenomenon is observed in transposition of the great arteries (TGA) with patent ductus arteriosis (PDA) and elevated pulmonary vascular resistance or in TGA with PDA and preductal aortic interruption or coarctation. This report describes a case of RDC not previously described involving an infant with supracardiac total anomalous pulmonary venous connection (TAPVC). In supracardiac TAPVC, RDC results from streaming of highly saturated superior vena cava (SVC) blood into the right ventricle, out the main pulmonary artery, through a PDA, and to the descending aorta, with streaming of more desaturated blood from the inferior vena cava (IVC) into the left atrium across the atrial septal defect (ASD)/foramen ovale. Therefore, as part of a neonatal examination to rule out congenital heart disease (CHD), simultaneous pre- and postductal oxygen saturations should be documented. The presence of RDC should initiate immediate full cardiac evaluation for CHD. Supracardiac TAPVC should be included in the differential diagnosis if RDC is observed.

  2. Atrial cardiomyoplasty in a Fontan circulation.

    PubMed

    Voss, Bernhard; Sack, Falk-Udo; Saggau, Werner; Hagl, Siegfried; Lange, Rüdiger

    2002-05-01

    The Fontan circulation is a direct connection between the systemic veins and the pulmonary artery (PA). Consequently, the pulmonary flow is passive due to the gradient between the right and left atrial pressure. In patients with increased pulmonary vascular resistance, the surgical procedure of atrio-pulmonary connection is therefore prone to failure. The goal of this experiment was to increase the pulmonary flow in an experimental model of a Fontan circulation by performing a right atrial cardiomyoplasty (ACMP). In 19 Foxhounds the left m. latissimus dorsi (LD) was mobilised and transferred as a pedicle into the chest. After sternotomy a 'Fontan circulation' was created under cardiopulmonary bypass (CPB) by connecting the right atrium (RA) with the PA by a valveless conduit. The tricuspid valve was closed with a patch. In 11 dogs (group 1) a valve was implanted in the inferior vena cava (IVC) and pulmonary inflow impedance was increased by partial occlusion of the conduit to a gradient of 10 mmHg between RA and PA. In the other eight dogs (group 2) no valve was implanted, but flowmeters were placed in the IVC and the superior vena cava (SVC). In all dogs the RA was enlarged by a fascia lata patch before the LD was wrapped over the RA and stimulated synchronously to the R-wave with burst impulses. After coming off CPB, relatively high central venous pressures (22.5+/-5.8 mmHg) were necessary to maintain haemodynamic stability. With LD-stimulation in a 1:3 mode in group 1, RA pressure (P) increased from 23.1+/-7.7 to 45+/-10.5 mmHg (P<0.001), pulmonary atrial pressure (PAP) from 15.5+/-4.3 to 25.5+/-7.6 mmHg (P<0.001) and central venous pressure increased to 33.1+/-11.3 mmHg (P<0.05). Stroke volume increase from 11.4+/-4.7 to 17.2+/-4.3 ml and peak conduit-flow from 1286.3+/-880.3 to 2329+/-1173 ml/min (all P<0.001). In a 1:1 stimulation mode a pulsatile pressure/flow profile was obtained in the PA-conduit. Furthermore, at higher frequencies of about 120 beats/min muscle relaxation was still fast enough as not to interfere with the RA filling. In group 2 caval flow without stimulation occurred mainly during diastole. However, with LD-stimulation, a strong backflow into IVC and SVC was observed resulting in a less pronounced pressure/flow increase in the PA. Our experimental model demonstrates the possibility of a 'ventricularisation' of the RA by using the force of the LD. However, the haemodynamic benefit of ACMP was achieved only, when a valve was implanted in the ICV.

  3. Using of porous portion to simulate pulmonary resistance in the computational fluid dynamic models of Fontan connection.

    PubMed

    Sun, Qi; Liu, Jinlong; Qian, Yi; Hong, Haifa; Liu, Jinfen

    2013-01-01

    In this study, we performed computational fluid dynamic (CFD) simulations in a patient-specific three-dimensional extracardiac conduit Fontan connection. The pulmonary resistance was incorporated in the CFD model by connecting porous portions in the left and right pulmonary arteries. The pressure in the common atrium was set as boundary conditions at the outlets of the pulmonary arteries. The flow rate in the innominate veins and the inferior vena cava (IVC) was set as inflow boundary conditions. Furthermore, the inflow rate of IVC was increased to 2 and 3 times of that measured to perform another two simulations and the resistance provided by the porous portions was compared among these three conditions. We found out that the pulmonary resistance set as porous portion in the CFD models remains relatively steady despite the change of the inflow rate. We concluded that, in the CFD simulations for the Fontan connections, porous portion could be used to represent pulmonary resistance steadily. The pulmonary resistance and pressure in the common atrium could be acquired directly by clinical examination. The employment of porous portion together with pressure in the common atrium in the CFD model could facilitate and accurate the set of outlet boundary conditions especially for those actual pulmonary flow splits was unpredictable such as virtual operative designs related CFD simulations.

  4. Fuzzy rule-based image segmentation in dynamic MR images of the liver

    NASA Astrophysics Data System (ADS)

    Kobashi, Syoji; Hata, Yutaka; Tokimoto, Yasuhiro; Ishikawa, Makato

    2000-06-01

    This paper presents a fuzzy rule-based region growing method for segmenting two-dimensional (2-D) and three-dimensional (3- D) magnetic resonance (MR) images. The method is an extension of the conventional region growing method. The proposed method evaluates the growing criteria by using fuzzy inference techniques. The use of the fuzzy if-then rules is appropriate for describing the knowledge of the legions on the MR images. To evaluate the performance of the proposed method, it was applied to artificially generated images. In comparison with the conventional method, the proposed method shows high robustness for noisy images. The method then applied for segmenting the dynamic MR images of the liver. The dynamic MR imaging has been used for diagnosis of hepatocellular carcinoma (HCC), portal hypertension, and so on. Segmenting the liver, portal vein (PV), and inferior vena cava (IVC) can give useful description for the diagnosis, and is a basis work of a pres-surgery planning system and a virtual endoscope. To apply the proposed method, fuzzy if-then rules are derived from the time-density curve of ROIs. In the experimental results, the 2-D reconstructed and 3-D rendered images of the segmented liver, PV, and IVC are shown. The evaluation by a physician shows that the generated images are comparable to the hepatic anatomy, and they would be useful to understanding, diagnosis, and pre-surgery planning.

  5. Postcorrective surgery improvement of nocturnal hypoxemia in a case of partial anomalous pulmonary venous connection and aberrant hepatic vein drainage.

    PubMed

    Agrawal, Abhinav; Palkar, Atul V; Sahni, Sonu; Vatsia, Sheel K; Shah, Rakesh D; Talwar, Arunabh

    2016-01-01

    Partial anomalous pulmonary venous connection (PAPVC) is a rare congenital anomaly that leads to an anatomical left-to-right shunt. Termination of the intrahepatic inferior vena cava (IVC) with its azygos continuation associated with the hepatic venous connection to the left atrium (LA) is also a rare congenital anomaly that results in an anatomical right-to-left shunt. A 65-year-old male presented with severe dyspnea on exertion and pedal edema. He was further diagnosed at our clinic and was found to have both the aforementioned congenital abnormalities, creating a bidirectional shunt. On further investigation, he was found to have nocturnal hypoxemia on overnight oximetry. The patient was successfully treated via surgical corrections of the congenital anomalies leading to symptomatic improvement as well as the resolution of nocturnal hypoxemia.

  6. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.

    2006-10-15

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to themore » azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved.« less

  7. Retrievable Inferior Vena Cava Filters in Trauma Patients: Prevalence and Management of Thrombus Within the Filter.

    PubMed

    Pan, Y; Zhao, J; Mei, J; Shao, M; Zhang, J; Wu, H

    2016-12-01

    The incidence of thrombus was investigated within retrievable filters placed in trauma patients with confirmed DVT at the time of retrieval and the optimal treatment for this clinical scenario was assessed. A technique called "filter retrieval with manual negative pressure aspiration thrombectomy" for management of filter thrombus was introduced and assessed. The retrievable filters referred for retrieval between January 2008 and December 2015 were retrospectively reviewed to determine the incidence of filter thrombus on a pre-retrieval cavogram. The clinical outcomes of different managements for thrombus within filters were recorded and analyzed. During the study 764 patients having Aegisy Filters implanted were referred for filter removal, from which 236 cases (134 male patients, mean age 50.2 years) of thrombus within the filter were observed on initial pre-retrieval IVC venogram 12-39 days after insertion (average 16.9 days). The incidence of infra-filter thrombus was 30.9%, and complete occlusion of the filter bearing IVC was seen in 2.4% (18) of cases. Retrieval was attempted in all 121 cases with small clots using a regular snare and sheath technique, and was successful in 120. A total of 116 cases with massive thrombus and IVC occlusion by thrombus were treated by CDT and/or the new retrieval technique. Overall, 213 cases (90.3%) of thrombus in the filter were removed successfully without PE. A small thrombus within the filter can be safely removed without additional management. CDT for reduction of the clot burden in filters was effective and safe. Filter retrieval with manual negative pressure aspiration thrombectomy seemed reasonable and valuable for management of massive thrombus within filters in some patients. Full assessment of the value and safety of this technique requires additional studies. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study

    PubMed Central

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Objectives Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. Methods HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Results Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Conclusions Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. Trial registration number NCT01794715. PMID:26438785

  9. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study.

    PubMed

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. NCT01794715. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Gunther Tulip Retrievable Inferior Vena Caval Filters: Indications, Efficacy, Retrieval, and Complications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Looby, S.; Given, M.F.; Geoghegan, T.

    Purpose. We evaluated the Gunther Tulip (GT) retrievable inferior vena cava (IVC) filter with regard to indications, filtration efficacy, complications, retrieval window, and use of anticoagulation. Method. A retrospective study was performed of 147 patients (64 men, 83 women; mean age 58.8 years) who underwent retrievable GT filter insertion between 2001 and 2005. The indications for placement included a diagnosis of pulmonary embolism or deep venous thrombosis with a contraindication to anticoagulation (n = 68), pulmonary embolism or deep venous thrombosis while on anticoagulation (n = 49), prophylactic filter placement for high-risk surgical patients with a past history of pulmonarymore » embolism or deep venous thrombosis (n = 20), and a high risk of pulmonary embolism or deep venous thrombosis (n = 10). Forty-nine of the 147 patients did not receive anticoagulation (33.7%) while 96 of 147 patients did, 82 of these receiving warfarin (56.5%), 11 receiving low-molecular weight heparins (7.58%), and 3 receiving antiplatelet agents alone (2.06%). Results. Filter placement was successful in 147 patients (100%). Two patients had two filters inserted. Of the 147 patients, filter deployment was on a permanent basis in 102 and with an intention to retrieve in 45 patients. There were 36 (80%) successful retrievals and 9 (20%) failed retrievals. The mean time to retrieval was 33.6 days. The reasons for failed retrieval included filter struts tightly adherent to the IVC wall (5/9), extreme filter tilt (2/9), and extensive filter thrombus (2/9). Complications included pneumothorax (n = 4), failure of filter expansion (n = 1), and breakthrough pulmonary embolism (n = 1). No IVC thrombotic episodes were recorded. Discussion. The Gunther Tulip retrievable filter can be used as a permanent or a retrievable filter. It is safe and efficacious. GT filters can be safely retrieved at a mean time interval of 33.6 days. The newly developed Celect filter may extend the retrieval interval.« less

  11. Ecklonia cava Extract and Dieckol Attenuate Cellular Lipid Peroxidation in Keratinocytes Exposed to PM10.

    PubMed

    Lee, Jeong-Won; Seok, Jin Kyung; Boo, Yong Chool

    2018-01-01

    Airborne particulate matter can cause oxidative stress, inflammation, and premature skin aging. Marine plants such as Ecklonia cava Kjellman contain high amounts of polyphenolic antioxidants. The purpose of this study was to examine the antioxidative effects of E. cava extract in cultured keratinocytes exposed to airborne particulate matter with a diameter of <10  μ m (PM10). After the exposure of cultured HaCaT keratinocytes to PM10 in the absence and presence of E. cava extract and its constituents, cell viability and cellular lipid peroxidation were assessed. The effects of eckol and dieckol on cellular lipid peroxidation and cytokine expression were examined in human epidermal keratinocytes exposed to PM10. The total phenolic content of E. cava extract was the highest among the 50 marine plant extracts examined. The exposure of HaCaT cells to PM10 decreased cell viability and increased lipid peroxidation. The PM10-induced cellular lipid peroxidation was attenuated by E. cava extract and its ethyl acetate fraction. Dieckol more effectively attenuated cellular lipid peroxidation than eckol in both HaCaT cells and human epidermal keratinocytes. Dieckol and eckol attenuated the expression of inflammatory cytokines such as tumor necrosis factor- (TNF-) α , interleukin- (IL-) 1 β , IL-6, and IL-8 in human epidermal keratinocytes stimulated with PM10. This study suggested that the polyphenolic constituents of E. cava , such as dieckol, attenuated the oxidative and inflammatory reactions in skin cells exposed to airborne particulate matter.

  12. Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.

    PubMed

    Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek

    2003-05-01

    Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.

  13. Ovine secondary follicles vitrified out the ovarian tissue grow and develop in vitro better than those vitrified into the ovarian fragments.

    PubMed

    Lunardi, Franciele Osmarini; de Aguiar, Francisco Leo Nascimento; Duarte, Ana Beatriz Graça; Araújo, Valdevane Rocha; de Lima, Laritza Ferreira; Ribeiro de Sá, Naiza Arcângela; Vieira Correia, Hudson Henrique; Domingues, Sheyla Farhayldes Souza; Campello, Cláudio Cabral; Smitz, Johan; de Figueiredo, José Ricardo; Ribeiro Rodrigues, Ana Paula

    2016-04-15

    Cryopreservation of preantral follicles is a promising technique to preserve female fertility. The aim of this study was to evaluate the effect of vitrification on the development of secondary follicles included in ovarian tissue or isolated after microdissection. An important end point included is the capacity of grown oocytes to resume meiosis. Sheep ovarian cortexes were cut into fragments and split into three different groups: (1) fresh (control): secondary follicles isolated without any previous vitrification; (2) follicle-vitrification (follicle-vit): secondary follicles vitrified in isolated form; and (3) tissue-vitrification (tissue-vit): secondary follicles vitrified within fragments of ovarian tissue (in situ former) and subsequently subjected to isolation. From the three groups, isolated secondary follicles were submitted to IVC for 18 days. After IVC, cumulus-oocyte complexes (COCs) were harvested from follicles. As an additional control group, in vivo grown, in vivo-grown COCs were collected from antral ovarian follicles. All, recovered COCs were matured and the chromatin configuration was evaluated. Data were analyzed by ANOVA, and the means were compared by Student-Newman-Keuls test, and by chi-square. Differences were considered to be significant when P < 0.05. Isolated preantral follicles from all treatments had normal morphology, antrum formation, and low follicle degeneration after IVC. The growth rate between control and follicle-vit did not differ (P > 0.05), and was higher (P < 0.05) than for tissue-vit. The percentage of follicles that decreased diameter during IVC was significantly higher in tissue-vit than the in follicle-vit. Recovery rate of oocytes from normal follicles was higher in follicle-vit than in tissue-vit. Furthermore, oocyte viability was lower in tissue-vit than other treatments, and follicle-vit did not differ from control and in vivo grown. The percentage of oocytes meiosis resuming was not different between treatments except for in vivo grown. After vitrification, only follicle-vit showed metaphase I oocyte. We conclude that secondary follicles vitrified after isolation displayed a better follicular growth rate, oocyte viability, percentage of oocytes reaching the metaphase I stage, and fewer follicles with decreased diameter after IVC. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The high-risk polytrauma patient and inferior vena cava filter use.

    PubMed

    Berber, Onur; Vasireddy, Aswin; Nzeako, Obi; Tavakkolizadeh, Adel

    2017-07-01

    The aim of this study was to assess the impact on practice of vena cava filter insertion guidelines (Eastern Association for the Surgery of Trauma: practice management guidelines). The study was performed at a level 1 trauma centre with data from the 'Trauma Audit and Research Network' cross-referenced to hospital data. A total of 1138 specific 'high-risk' major trauma patients were identified over a 6-year period. The mean age was 46 years (18-102) and the male to female ratio was 3.3:1. The average Injury Severity Score was 23.6 (4-75). The overall DVT rate was 2.6% and the PE rate was 1.8%. A retrievable IVC filter was inserted in 42 cases (3.8%). The filter retrieval rate was 23.8% at a mean of 68.5days (4-107). Only one complication was reported of a breakthrough PE despite filter. Applying the EAST guidelines to this cohort would have suggested filter insertion in 279 (24.6%) cases. The kappa concordance value between observed practice and the 'EAST filter group' was 0.103 (poor). The PE rate in the 'EAST filter group' was 2.2% vs 1.6% in the 'no filter group' (p=0.601, no statistical difference) and the observed odds ratio was 0.814 (95% CI 0.413, 1.602). The EAST guidelines are useful but may be overestimating the need for filter insertion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. A Retroaortic Left Renal Vein in a Female Cadaver.

    PubMed

    Fujishima, Yoshiko; Watanabe, Koichi; Tabira, Yoko; Iwanaga, Joe; Odo, Yui; Saga, Tsuyoshi; Tubbs, R Shane; Yamaki, Koh-Ichi

    2018-05-21

    We encountered a case of retroaortic left renal vein (RLRV) during an anatomical dissection course at our medical school in 2017. The case was a female cadaver who was 88 years old at death. Six roots of the left renal vein (RV) arose from the hilus of the kidney and joined to form one left renal vein, crossed dorsal to the abdominal aorta (AA) at the level of the second lumbar vertebra, and then drained into the inferior vena cava (IVC). Two roots joined at the right renal hilus to become the right RV to then drain into the IVC at the level of the first lumbar vertebral body. The reported frequency of RLRV is approximately 2%. Embryologically, the normal anastomosis of the left and right sub-cardinal veins results in the left RV traveling on the ventral surface of the AA. However, in the case presented here, the left RV traveled on the dorsal side of the AA due to the anastomosis of the left and right supra-cardinal veins and regression of the anastomosis between the left and right sub-cardinal veins. If both the dorsal and ventral anastomoses remain, the left RV travels on the dorsal and ventral sides of the aorta. Some of the clinical problems reported in association with RLRV are hematuria and abdominal pain, and the risk of damaging the RLRV during surgery of the posterior abdominal wall. Venous variants as reported herein should be kept in mind when interpreting imaging of the posterior abdominal wall or performing surgery or other invasive procedures near the RLRV.

  16. Achieving normothermia in patients with febrile subarachnoid hemorrhage: feasibility and safety of a novel intravascular cooling catheter.

    PubMed

    Badjatia, Neeraj; O'Donnell, Joan; Baker, John R; Huang, David; Ayata, Cenk; Greer, David M; Carter, Bob S; Ogilvy, Christopher S; McDonald, Colin T

    2004-01-01

    Fever is common and difficult to control in patients with subarachnoid hemorrhage (SAH). We have previously shown an inverse relationship between fever and outcome in patients with SAH. This was a prospective, single-arm, feasibility trial in which nine patients with SAH underwent temperature management using an intravascular cooling catheter (ICC) to restore and maintain 24 hours of normothermia (36.5 degrees+/-0.2 degrees C). Enrollment occurred after development of a fever of at least 38.3 degrees C within 7 days of SAH that was refractory to acetaminophen treatment. The ICC was placed at the bedside through an introducer sheath via the femoral vein into the inferior vena cava (IVC). Portable X-ray confirmed placement. Normothermia was achieved in seven of the nine patients treated (78%); it was achieved in 100% of the patients with a 14F catheter (n=4) and in 60% of the patients with a 9F catheter (n=5). The two patients not reaching normothermia were not adequately treated for shivering. All other patients reached normothermia irrespective of intubation status. Overall, normothermia was well tolerated and not discontinued because of discomfort or adverse events. Two incidences of deep vein thrombosis were diagnosis by ultrasound that were not associated with clinical sequelae, and IVC filters were placed. No unanticipated adverse events occurred. We have demonstrated that fever can be safely and effectively controlled in patients with SAH for at least 24 hours using an ICC. Future studies are needed to assess the effect of such sustained therapy on outcome in patients with SAH.

  17. Can Patients Comprehend the Educational Materials that Hospitals Provide about Common IR Procedures?

    PubMed

    Sadigh, Gelareh; Hawkins, C Matthew; O'Keefe, John J; Khan, Ramsha; Duszak, Richard

    2015-08-01

    To assess the readability of online education materials offered by hospitals describing commonly performed interventional radiology (IR) procedures. Online patient education materials from 402 hospitals selected from the Medicare Hospital Compare database were assessed. The presence of an IR service was determined by representation in the Society of Interventional Radiology physician finder directory. Patient online education materials about (i) uterine artery embolization for fibroid tumors, (ii) liver cancer embolization, (iii) varicose vein treatment, (iv) central venous access, (v) inferior vena cava (IVC) filter placement, (vi) nephrostomy tube insertion, (vii) gastrostomy tube placement, and (viii) vertebral augmentation were targeted and assessed by using six validated readability scoring systems. Of 402 hospitals sampled, 156 (39%) were presumed to offer IR services. Of these, 119 (76%) offered online patient education material for one or more of the eight service lines. The average readability scores corresponding to grade varied between the ninth- and 12th-grade levels. All were higher than the recommended seventh-grade level (P < .05) except for nephrostomy and gastrostomy tube placement. Average Flesch-Kincaid Reading Ease scores ranged from 42 to 69, corresponding with fairly difficult to difficult readability for all service lines except IVC filter and gastrostomy tube placement, which corresponded with standard readability. A majority of hospitals offering IR services provide at least some online patient education material. Most, however, are written significantly above the reading comprehension level of most Americans. More attention to health literacy by hospitals and IR physicians is warranted. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  18. Infusion System Architecture Impacts the Ability of Intensive Care Nurses to Maintain Hemodynamic Stability in a Living Swine Simulator.

    PubMed

    Pezone, Matthew J; Peterfreund, Robert A; Maslov, Mikhail Y; Govindaswamy, Radhika R; Lovich, Mark A

    2016-05-01

    The authors have previously shown that drug infusion systems with large common volumes exhibit long delays in reaching steady-state drug delivery and pharmacodynamic effects compared with smaller common-volume systems. The authors hypothesized that such delays can impede the pharmacologic restoration of hemodynamic stability. The authors created a living swine simulator of hemodynamic instability in which occlusion balloons in the aorta and inferior vena cava (IVC) were used to manipulate blood pressure. Experienced intensive care unit nurses blinded to the use of small or large common-volume infusion systems were instructed to maintain mean arterial blood pressure between 70 and 90 mmHg using only sodium nitroprusside and norepinephrine infusions. Four conditions (IVC or aortic occlusions and small or large common volume) were tested 12 times in eight animals. After aortic occlusion, the time to restore mean arterial pressure to range (t1: 2.4 ± 1.4 vs. 5.0 ± 2.3 min, P = 0.003, average ± SD), time-out-of-range (tOR: 6.2 ± 3.5 vs. 9.5 ± 3.4 min, P = 0.028), and area-out-of-range (pressure-time integral: 84 ± 47 vs. 170 ± 100 mmHg · min, P = 0.018) were all lower with smaller common volumes. After IVC occlusion, t1 (3.7 ± 2.2 vs. 7.1 ± 2.6 min, P = 0.002), tOR (6.3 ± 3.5 vs. 11 ± 3.0 min, P = 0.007), and area-out-of-range (110 ± 93 vs. 270 ± 140 mmHg · min, P = 0.003) were all lower with smaller common volumes. Common-volume size did not impact the total amount infused of either drug. Nurses did not respond as effectively to hemodynamic instability when drugs flowed through large common-volume infusion systems. These findings suggest that drug infusion system common volume may have clinical impact, should be minimized to the greatest extent possible, and warrants clinical investigations.

  19. Anatomical basis of the liver hanging maneuver.

    PubMed

    Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija

    2005-01-01

    The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).

  20. Alginate beads as a tool to handle, cryopreserve and culture isolated human primordial/primary follicles.

    PubMed

    Camboni, A; Van Langendonckt, A; Donnez, J; Vanacker, J; Dolmans, M M; Amorim, C A

    2013-08-01

    One major concern of grafting cryopreserved ovarian tissue to restore fertility in cancer patients is the possibility of reintroducing tumor cells. Cryopreservation of isolated primordial/primary follicles (PFs) may circumvent this problem. The aim of our work was to compare dimethyl sulfoxide (ME2SO) and ethylene glycol (EG) as cryoprotectants (CPAs) for slow-freezing of isolated human PFs in alginate. Ovarian biopsies from four women were processed for follicle isolation. PFs were embedded in alginate (5-15 per group). Follicles were frozen-thawed using 1.4M ME2SO or 1.5M EG as CPAs. Fresh and cryopreserved isolated follicles were in vitro cultured (IVC) for 7 days. At different time periods (after isolation, cryopreservation and IVC), follicles were evaluated with live/dead assay (using fluorescent probes) and diameter measurement. Follicle viability was calculated according to the percentage of dead follicular cells and the presence of a live/dead oocyte. A total of 841 PFs were isolated, embedded in alginate and cryopreserved with ME2SO (n=424) or EG (n=259), or used as controls (n=158). After 7 days of IVC, a significant increase in follicle size was observed in the fresh and ME2SO groups, but not in the EG group. The percentage of totally viable PFs was not significantly different before or after seven days of culture in fresh (100% and 82%) or ME2SO (93.2% and 85.1%) tissue. The EG group showed significantly lower viability before (63.9%) and after IVC (66.2%) than the fresh and ME2SO groups. Our results show that 1.4M ME2SO yields better preservation of isolated PF viability after thawing and 7 days of IVC than 1.5M EG. Alginate constitutes an easy, safe hydrogel matrix to handle and cryopreserve isolated human follicles using ME2SO as a CPA. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Evaluating MRI based vascular wall motion as a biomarker of Fontan hemodynamic performance

    NASA Astrophysics Data System (ADS)

    Menon, Prahlad G.; Hong, Haifa

    2015-03-01

    The Fontan procedure for single-ventricle heart disease involves creation of pathways to divert venous blood from the superior & inferior venacavae (SVC, IVC) directly into the pulmonary arteries (PA), bypassing the right ventricle. For optimal surgical outcomes, venous flow energy loss in the resulting vascular construction must be minimized and ensuring close to equal flow distribution from the Fontan conduit connecting IVC to the left & right PA is paramount. This requires patient-specific hemodynamic evaluation using computational fluid dynamics (CFD) simulations which are often time and resource intensive, limiting applicability for real-time patient management in the clinic. In this study, we report preliminary efforts at identifying a new non-invasive imaging based surrogate for CFD simulated hemodynamics. We establish correlations between computed hemodynamic criteria from CFD modeling and cumulative wall displacement characteristics of the Fontan conduit quantified from cine cardiovascular MRI segmentations over time (i.e. 20 cardiac phases gated from the start of ventricular systole), in 5 unique Fontan surgical connections. To focus our attention on diameter variations while discounting side-to-side swaying motion of the Fontan conduit, the difference between its instantaneous regional expansion and inward contraction (averaged across the conduit) was computed and analyzed. Maximum Fontan conduit-average expansion over the cardiac cycle correlated with the anatomy-specific diametric offset between the axis of the IVC and SVC (r2=0.13, p=0.55) - a known factor correlated with Fontan energy loss and IVC-to-PA flow distribution. Investigation in a larger study cohort is needed to establish stronger statistical correlations.

  2. Behcet's disease in Budd-Chiari syndrome.

    PubMed

    Desbois, Anne Claire; Rautou, Pierre Emmanuel; Biard, Lucie; Belmatoug, Nadia; Wechsler, Bertrand; Resche-Rigon, Mathieu; Zarrouk, Virginie; Fantin, Bruno; de Chambrun, M Pineton; Cacoub, Patrice; Valla, Dominique; Saadoun, David; Plessier, Aurélie

    2014-01-01

    Behcet's disease (BD) is a well-known cause of Budd-Chiari syndrome (BCS). Data are lacking on the presentation and outcome of BCS related to BD. We investigated the relationship between BD and BCS in 14 patients with both diseases and compared the results to 92 BCS patients without BD. Male gender (p = 0.003), North African origin (P = 0.007) and inferior vena cava obstruction (P < 0.0001) were more frequent in patients with BD and BCS than in those with BCS alone and the plasma C-reactive protein level was higher (p = 0.003). Two of the patients with the combined diseases underwent recanalization of the vena cava and the hepatic veins, none received transjugular intrahepatic portosystemic shunts (TIPS), one received a surgical shunt and one underwent liver transplantation. TIPS were less frequent in patients with BD and BCS than in those with BCS alone (P = 0.019). Eighty six per cent of patients with BCS and BD received corticosteroids and immunosuppressive therapy. The 5-year transplantation-free survival rate was 63% in patients with BCS alone and 91% in those without BD (P = 0.11). In our series and in the literature, a high number of patients [12 (61.5%) and 11 (64.7%) respectively] treated with anticoagulation and corticosteroids and/or immunosuppressants did not require invasive treatment. This study shows a higher frequency of IVC obstruction in patients with BCS and BD. Medical treatment with anticoagulation and immunosuppressive agents may improve the symptoms of BCS. Therefore early management with immunosuppressive and anticoagulation therapy appears to be the treatment of choice in patients with BCS and BD.

  3. Ultrasonography of the liver, spleen, and urinary tract of the cheetah (Acinonyx jubatus).

    PubMed

    Carstens, Ann; Kirberger, Robert M; Spotswood, Tim; Wagner, Wencke M; Grimbeek, Richard J

    2006-01-01

    Diseases of the abdomen of the cheetah (Acinonyx jubatus) include those affecting the liver, spleen, and urinary tract. The most common diseases of captive-bred cheetah are gastritis, gastric ulceration, glomerulosclerosis, and hepatic veno-occlusive disease, and are the most frequent causes of mortality in these animals. The purpose of this study was to describe the ultrasonographic anatomy of the normal liver, spleen, kidney, and urinary bladder of the anesthetized captive-bred cheetah. Twenty-one cheetahs were examined. Eight of the 21 animals had subclinical evidence of either gastritis or chronic renal disease. The ultrasonographic appearances of the liver, gall bladder, common bile duct, and spleen were evaluated and various measurements made. Statistical analyses of the measurements were performed on all the healthy and subclinically ill animals taking sex, age, mass, and anesthetic protocol into account. There were no significant differences in any parameters between the healthy and subclinically ill animals (P > 0.25) and data were combined for statistical analyses. The mean mass was 41.1kg ( +/- 8.8) and the mean age was 5.0 years (+/- 2.2). The mean thickness of the liver medial to the gall bladder was 67.0 mm (+/- 14.8) and the liver was within the left costal arch in 75% of animals, extended caudal to the right costal arch in 50% of animals for an average of 30 mm, and extended caudal to the sternum in 63% of animals for an average of 32.5 mm. The maximum mean hepatic vein diameter at the entrance to the caudal vena cava was 8.6 +/- 2.8 mm; the mean diameters of the portal vein at the hilus and that of the caudal vena cava as it entered the liver were 7.5 +/- 1.6 and 9.9 +/- 4.1 mm, respectively. The mean diameter of the caudal vena cava was significantly affected by the type of anesthetic used (P < 0.10). The mass of the animals was significant in explaining the variance in maximum portal vein diameters (P < 0.10). The mean maximum velocity of the hepatic vein flow at the entrance to the caudal vena cava was 25.3 +/- 2.8 cm/s (n=4), the hilar portal vein was 11.7 +/- 3.3 cm/s (n=7), and the caudal vena cava was 33.8 +/- 19.8 cm/s (n=5). The mean maximum gall bladder length and width, and the mean common bile duct diameters were 44.6 mm (+/- 10.4), 23.3 mm (+/- 5.0), and 8.1 mm (+/- 2.4), respectively. Age was significant in explaining the variance in gall bladder lengths (P<0.10). Urinary tract ultrasonography was performed only in animals that had normal urea and creatinine levels (n=13). Renal cortico-medullary distinction was present in all kidneys and a cortico-medullary rim sign was seen in 21 of 26 kidneys. Mean kidney length, height, and width was 63.9 +/- 5.7, 38.1 +/- 5.2, and 42.1 +/- 5 mm, respectively. The average resistivity index was 0.58 (n=5). Mean urinary bladder length, height, and width were 57.0, 19.2, and 34.9 mm, respectively.

  4. Left Recumbent Position Decreases Heart Rate without Alterations in Cardiac Autonomic Nervous System Activity in Healthy Young Adults.

    PubMed

    Sasaki, Konosuke; Haga, Mayu; Endo, Yoichi; Fujiwara, Junko; Maruyama, Ryoko

    2017-04-01

    Some studies have reported that recumbent position may have advantages in patients with heart disease and in pregnancy. However, it remains controversial whether recumbent position affects autonomic nervous system activity and hemodynamics in healthy adults. The aim of this study was to evaluate alterations in heart rate variability (HRV) and hemodynamics in the supine, left recumbent and right recumbent positions in healthy young adults. A total of 80 participants aged 22.8 ± 3.1 years were enrolled in this observational study. Fifty-eight volunteers (29 men and 29 women) maintained the supine position followed by the left and right recumbent positions, while electrocardiographic data were recorded for spectral analysis of HRV to assess cardiac vagal nerve and sympathetic nerve activities. The heart rate (HR) was significantly lower in the left recumbent position than in the other positions. There were no statistically significant differences in HRV among the three positions. Considering the possibility that the echographic procedure affects autonomic nervous system (ANS) activity, the other 22 participants (11 men and 11 women) underwent an echographic evaluation of hemodynamics in the heart and inferior vena cava (IVC) across the three positions. Although a low HR was also observed, there were no statistically significant differences in the IVC or the heart blood volume between the supine and the left recumbent positions. A postural change to the left recumbent position does not affect the cardiac blood circulation or ANS activity, though it does decrease HR in healthy young adults. This finding indicates that the lower HR in the left recumbent position is not attributable to the ANS activity.

  5. Adrenocortical carcinoma with inferior vena cava, left renal vein and right atrium tumor thrombus extension

    PubMed Central

    Annamaria, Pronio; Silvia, Piroli; Bernardo, Ciamberlano; Alessandro, De Luca; Antonino, Marullo; Antonio, Barretta; Giuseppe, Mazzesi; Massimo, Rossi; Montesani, Chiara

    2015-01-01

    Introduction Adrenocortical carcinoma (ACC) is a rare, but highly aggressive type of tumor with an annual incidence of 1–2 cases per million. The prognosis is poor with a five-year overall survival rate of ∼35%. The poor prognosis may be related to the advanced stage at which the majority of ACCs are detected. Complete surgical resection remains the most effective treatment. Presentation of the case A 51-year-old female patient with recent onset of dyspepsia, ascites and peripheral edema was referred to our institution. Computed tomography (CT) and Magnetic Resonance Imaging (MRI) displayed a 8 cm Ø right adrenal mass. Moreover a tumor thrombus jutted out into the IVC, left renal vein and right atrium. An echocardiographic evaluation confirmed the presence of the tumor thrombus in the right atrium. The patient underwent adrenalectomy with removal of its intravascular extension with the assistance of cardiopulmonary bypass and hypothermia. Discussion ACC is a rare malignancy and ACC with tumor thrombus extension is a rare presentation. Patients can present with a variety of sign and symptoms, depending on the extent of the tumor. CT scan of chest and abdomen represents the gold standard in ACC staging while magnetic resonance imaging (MRI) is preferred for tumor thrombus characterization. Complete surgical resection with a negative margin, R0 resection, is the only curative option for localized disease. Kidney sparing surgery should be performed when possible. Conclusion We present a rare case of Adrenocortical carcinoma with tumor thrombus extending into the IVC and right atrium. Complete resection with negative margins represents the best therapeutic chance for these patients. PMID:26355237

  6. Adrenocortical carcinoma with inferior vena cava, left renal vein and right atrium tumor thrombus extension.

    PubMed

    Annamaria, Pronio; Silvia, Piroli; Bernardo, Ciamberlano; Alessandro, De Luca; Antonino, Marullo; Antonio, Barretta; Giuseppe, Mazzesi; Massimo, Rossi; Montesani, Chiara

    2015-01-01

    Adrenocortical carcinoma (ACC) is a rare, but highly aggressive type of tumor with an annual incidence of 1-2 cases per million. The prognosis is poor with a five-year overall survival rate of ∼35%. The poor prognosis may be related to the advanced stage at which the majority of ACCs are detected. Complete surgical resection remains the most effective treatment. A 51-year-old female patient with recent onset of dyspepsia, ascites and peripheral edema was referred to our institution. Computed tomography (CT) and Magnetic Resonance Imaging (MRI) displayed a 8cm Ø right adrenal mass. Moreover a tumor thrombus jutted out into the IVC, left renal vein and right atrium. An echocardiographic evaluation confirmed the presence of the tumor thrombus in the right atrium. The patient underwent adrenalectomy with removal of its intravascular extension with the assistance of cardiopulmonary bypass and hypothermia. ACC is a rare malignancy and ACC with tumor thrombus extension is a rare presentation. Patients can present with a variety of sign and symptoms, depending on the extent of the tumor. CT scan of chest and abdomen represents the gold standard in ACC staging while magnetic resonance imaging (MRI) is preferred for tumor thrombus characterization. Complete surgical resection with a negative margin, R0 resection, is the only curative option for localized disease. Kidney sparing surgery should be performed when possible. We present a rare case of Adrenocortical carcinoma with tumor thrombus extending into the IVC and right atrium. Complete resection with negative margins represents the best therapeutic chance for these patients. Copyright © 2015. Published by Elsevier Ltd.

  7. Retrograde cerebral perfusion as an adjunct to prolonged hypothermic circulatory arrest.

    PubMed

    Esmailian, F; Dox, H; Sadeghi, A; Eghbali, K; Laks, H

    1999-10-01

    This study was designed to evaluate the use of retrograde cerebral perfusion (RCP) combined with deep hypothermic circulatory arrest (DHCA) in the treatment of complex congenital and adult cardiac disease. Retrospective chart review of 52 cardiac surgery patients (34 male and 18 female; age range, 3 weeks to 89 years old; mean age, 60 years old) who received RCP in conjunction with DHCA from July 1991 through August 1998. Surgical procedures consisted of the following: (1) repair of ascending aortic aneurysms (n = 16); (2) repair of type A aortic dissection (n = 16); (3) repair of arch aneurysms (n = 10); (4) renal cell carcinoma with tumor extension to the inferior vena cava (IVC) and right atrium (n = 5); (6) coronary artery bypass grafting and concomitant aortic valve replacement with calcified aorta (n = 2); (7) Norwood procedure and take down of a Pott's shunt (n = 2); and (8) massive air embolism treatment (n = 1). Mean RCP time was 39 min (range, 3 to 88 min). Thirteen patients had RCP times > 60 min. Mean core temperature (rectal or bladder) was 19 degrees C (range, 15 degrees to 28 degrees C). There were six early deaths, four of which were related to persistent low-output cardiac failure, and two resulted from perioperative stroke. All remaining patients recovered fully without neurologic deficits. RCP is a reliable and technically appealing tool that does the following: (1) it improves DHCA safety and is applicable in a variety of clinical settings with relative ease; (2) it potentially provides oxygen and nutritional support to the brain during DHCA; (3) it helps remove air and other debris from the cerebral vessels; and (4) it is useful in dealing with congenital heart disease and tumor extension into the IVC.

  8. Experimental Percutaneous Extrahepatic Portacaval Shunt Creation by Transjugular Approach in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seong, Chang Kyu; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Uchida, Barry T.

    2005-06-15

    The purpose of the study was to evaluate the feasibility of the creation of a percutaneous extrahepatic portacaval shunt (PEPS) in swine by a transjugular approach and to find a suitable stent-graft to use in PEPS. In 12 swine, the extrahepatic portal vein (PV) was entered from the inferior vena cava (IVC) by a needle system introduced from the transjugular approach. A catheter introduced through the transhepatic approach served as a target. Five types of stent-graft consisting of homemade Z stents and a polytetrafluoethylene cover were explored for PEPS creation. Eight animals had follow-up venograms up to 6 weeks ormore » until the shunt became severely stenotic. Gross and histologic examinations were performed after the final follow-up venography. The PV punctures and stent-graft placement were difficult, but the PEPS was established in all animals. In four animals, the stent-graft failed to adequately cover the tract, causing severe hemorrhage. Only two shunts remained patent up to 6 weeks. The other shunts exhibited severe stenosis or occlusion. At gross examination, all shunts traversed the liver parenchyma of the caudate lobe surrounding the IVC. The extravascular PEPS portion was 4 mm to 2 cm long. All shunts entered the PV close to the splenomesenteric junction and exhibited neointimal formation. Shunt stenoses were caused by neointimal hyperplasia and occlusions by a superimposed thrombus. PEPS can be created by the transjugular approach in swine, but only the PV shunt entrance is extrahepatic. None of the tested rigid stent-grafts were suitable for PEPS creation. A short flexible stent-graft with flanged ends is suggested for further exploration.« less

  9. Endotoxaemia-augmented murine venous thrombosis is dependent on TLR-4 and ICAM-1, and potentiated by neutropenia.

    PubMed

    Obi, Andrea T; Andraska, Elizabeth; Kanthi, Yogendra; Kessinger, Chase W; Elfline, Megan; Luke, Cathy; Siahaan, Teruna J; Jaffer, Farouc A; Wakefield, Thomas W; Henke, Peter K

    2017-01-26

    Venous thromboembolism is a major cause of death during and immediately post-sepsis. Venous thrombosis (VT) is mediated by cell adhesion molecules and leukocytes, including neutrophil extracellular traps (NETs). Sepsis, or experimentally, endotoxaemia, shares similar characteristics and is modulated via toll like receptor 4 (TLR4). This study was undertaken to determine if endotoxaemia potentiates early stasis thrombogenesis, and secondarily to determine the role of VT TLR4, ICAM-1 and neutrophils (PMNs). Wild-type (WT), ICAM-1 -/- and TLR4 -/- mice underwent treatment with saline or LPS (10 mg/kg i. p.) alone, or followed by inferior vena cava (IVC) ligation to generate stasis VT. In vivo microscopy of leukocyte trafficking was performed in non-thrombosed mice, and tissue and plasma were harvested during early VT formation. Pre-thrombosis, circulating ICAM-1 was elevated and increased leukocyte adhesion and rolling occurred on the IVC of LPS-treated mice. Post-thrombosis, endotoxaemic mice formed larger, platelet-poor thrombi. Endotoxaemic TLR4 -/- mice did not have an augmented thrombotic response and exhibited significantly decreased circulating ICAM-1 compared to endotoxaemic WT controls. Endotoxaemic ICAM-1 -/- mice had significantly smaller thrombi compared to controls. Hypothesising that PMNs localised to the inflamed endothelium were promoting thrombosis, PMN depletion using anti-Ly6G antibody was performed. Paradoxically, VT formed without PMNs was amplified, potentially related to endotoxaemia induced elevation of PAI-1 and circulating FXIII, and decreased uPA. Endotoxaemia enhanced early VT occurs in a TLR-4 and ICAM-1 dependent fashion, and is potentiated by neutropenia. ICAM-1 and/or TLR-4 inhibition may be a unique strategy to prevent sepsis-associated VT.

  10. Right adrenal vein: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction.

    PubMed

    Noda, Y; Goshima, S; Nagata, S; Miyoshi, T; Kawada, H; Kawai, N; Tanahashi, Y; Matsuo, M

    2018-06-01

    To compare right adrenal vein (RAV) visualisation and contrast enhancement degree on adrenal venous phase images reconstructed using adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) techniques. This prospective study was approved by the institutional review board, and written informed consent was waived. Fifty-seven consecutive patients who underwent adrenal venous phase imaging were enrolled. The same raw data were reconstructed using ASiR 40% and MBIR. The expert and beginner independently reviewed computed tomography (CT) images. RAV visualisation rates, background noise, and CT attenuation of the RAV, right adrenal gland, inferior vena cava (IVC), hepatic vein, and bilateral renal veins were compared between the two reconstruction techniques. RAV visualisation rates were higher with MBIR than with ASiR (95% versus 88%, p=0.13 in expert and 93% versus 75%, p=0.002 in beginner, respectively). RAV visualisation confidence ratings with MBIR were significantly greater than with ASiR (p<0.0001, both in the beginner and the expert). The mean background noise was significantly lower with MBIR than with ASiR (p<0.0001). Mean CT attenuation values of the RAV, right adrenal gland, IVC, and hepatic vein were comparable between the two techniques (p=0.12-0.91). Mean CT attenuation values of the bilateral renal veins were significantly higher with MBIR than with ASiR (p=0.0013 and 0.02). Reconstruction of adrenal venous phase images using MBIR significantly reduces background noise, leading to an improvement in the RAV visualisation compared with ASiR. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Fracture and distant migration of the Bard Recovery filter: a retrospective review of 363 implantations for potentially life-threatening complications.

    PubMed

    Tam, Matthew D; Spain, James; Lieber, Michael; Geisinger, Michael; Sands, Mark J; Wang, Weiping

    2012-02-01

    To report the occurrence of fracture of the Recovery filter and incidence of potentially life-threatening complications associated with fractured fragment migration. A retrospective study of images obtained after placement of Recovery inferior vena cava (IVC) filters from 2003 to 2006 was conducted at a single tertiary-care center. Images were reevaluated for fracture and migration; complications related to filter fracture were investigated. Kaplan-Meier survival analysis was performed to investigate the relationship between time in situ and fracture. A total of 363 Recovery filters were placed; 97 were retrieved, leaving 266 filters in situ (135 patients subsequently died of other causes). The following images were evaluated: 130 chest computed tomography (CT) scans, 153 abdominal CT scans, 254 chest radiographs, 148 radiographs of the abdomen/pelvis, and 106 cavagrams. Mean imaging follow-up interval was 18.4 months (maximum, 81.3 mo). No en bloc migration occurred outside the IVC. Twenty-six limb fractures (all short limbs) were identified in 20 patients; the earliest occurred at 4.1 months. Eight fragment migrations occurred into pulmonary arteries, seven into iliac/femoral veins, one into the right ventricle, and one into the renal vein. Seven fragments were intracaval near the filter, one was extracaval, and one could not be located. Kaplan-Meier survival estimates predicted a fracture rate of 40% at 5.5 years. Of the 20 patients with filter fractures, three died of unrelated causes and 17 remain asymptomatic. Recovery filter fractures occurred at the short limb only, with a suggested 5.5-year fracture risk of 40%. No life-threatening events occurred in patients with filter fracture. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  12. SU-G-IeP4-15: Ultrasound Imaging of Absorbable Inferior Vena Cava Filters for Proper Placement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitcham, T; Bouchard, R; Melancon, A

    Purpose: Inferior vena cava filters (IVCFs) are used in patients with a high risk of pulmonary embolism in situations when the use of blood thinning drugs would be inappropriate. These filters are implanted under x-ray guidance; however, this provides a dose of ionizing radiation to both patient and physician. B-mode ultrasound (US) imaging allows for localization of certain implanted devices without radiation dose concerns. The goal of this study was to investigate the feasibility of imaging the placement of absorbable IVCFs using US imaging to alleviate the dosage concern inherent to fluoroscopy. Methods: A phantom was constructed to mimic amore » human IVC using tissue-mimicking material with 0.5 dB/cm/MHz acoustic attenuation, while agar inclusions were used to model acoustic mismatch at the venous interface. Absorbable IVCF’s were imaged at 15 cm depth using B-mode US at 2, 3, 5, and 7 MHz transmit frequencies. Then, to determine temporal stability, the IVCF was left in the phantom for 10 weeks; during this time, the IVCF was imaged using the same techniques as above, while the integrity of the filter was analyzed by inspecting for fiber discontinuities. Results: Visualization of the inferior vena cava filter was possible at 5, 7.5, and 15 cm depth at US central frequencies of 2, 3, 5, and 7 MHz. Imaging the IVCF at 5 MHz yielded the clearest images while maintaining acceptable spatial resolution for identifying the IVCF’s, while lower frequencies provided noticeably worse image quality. No obvious degradation was observed over the course of the 10 weeks in a static phantom environment. Conclusion: Biodegradable IVCF localization was possible up to 15 cm in depth using conventional B-mode US in a tissue-mimicking phantom. This leads to the potential for using B-mode US to guide the placement of the IVCF upon deployment by the interventional radiologist. Mitch Eggers is an owner of Adient Medical Technologies. There are no other conflicts of interest to disclose.« less

  13. Fibrinolysis status in the Budd-Chiari syndrome in China.

    PubMed

    Ke, Zhang; Hao, Xu; Ning, Wei; Zu, Mao-heng; Fun, Yu-fei

    2015-10-01

    Pathogenesis and clinical characteristics of the Budd-Chiari syndrome (BCS) in Asia are somewhat different from the ones observed in Western countries. Obstruction of the inferior vena cava (IVC) or of the hepatic veins is caused to a greater extent by membranous webs than by thrombosis. Impaired fibrinolysis has been found in European patients with BCS, but its status in Chinese patients with this condition is still unknown. To explore the characteristics of fibrinolysis in BCS patients in this country, we measured the euglobulin lysis time (ELT) for overall fibrinolysis and the plasma levels of five fibrinolytic components in 65 Chinese patients with BCS and 43 healthy controls. In patients, ELTs were slightly shorter than in controls (mean, 293 vs. 357 min, P < 0.02), tissue type plasminogen activator levels were higher than in controls (mean, 239 vs. 185 pg/ml, P < 0.01), and plasminogen activator inhibitor 1 levels were lower than in controls (mean, 1.43 vs. 1.73 ng/ml, P < 0.001). To explore BCS in more detail, we subgrouped the cases according to age, type of venous occlusion, Child-Pugh score, and thrombosis. As a result of this analysis, we found that young patients (age <30 years) had a longer ELT (mean, 440 min) than the older patient groups (30 ≤ age ≤ 44, 45 ≤ age ≤ 54, age>54 years; mean ELT = 242, 198, and 289 min, respectively, all P < 0.05). The independent hepatic vein occlusion subgroup showed a longer ELT (mean, 367 min) than the combined hepatic vein and IVC or the independent IVC occlusion subgroup (mean ELT = 233 and 260 min, both P < 0.05). ELT did not show significant differences between Child-Pugh class A and B subgroups (mean, 267 vs. 333 min, P > 0.05). ELT in the subgroup without thrombosis was shorter than in controls (mean, 288 vs. 358 min, P < 0.05), and in the subgroup with thrombosis, it was also slightly shorter than in controls, without reaching statistical significance (mean, 306 vs. 358 min, P > 0.05). By and large, overall fibrinolytic potential was slightly increased in Chinese patients with BCS in this study, but fibrinolysis differed according to its baseline characteristics. Compared with the one seen in BCS patients from Western countries, BCS in China exhibits certain special changes in fibrinolysis and we were able to explain some of these changes.

  14. Liver hanging maneuver for right hemiliver in situ donation--anatomical considerations.

    PubMed

    Trotovsek, B; Gadzijev, E M; Ravnik, D; Hribernik, M

    2006-01-01

    An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4-6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7+/-3.4 mm and to the entrance of segment 9 veins was 5.0+/-0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7+/-2.3 mm (range 2-15 mm). The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%).

  15. [Pulsatile total cavopulmonary shunt for hypoplastic right heart syndrome with abnormal systemic venous return--a case report].

    PubMed

    Oiwa, H; Kawauchi, M; Chikada, M; Yagyu, K; Kotsuka, Y; Furuse, A

    1995-01-01

    A pulsatile total cavopulmonary shunt was successfully performed on a 5-year-old girl with hypoplastic right heart syndrome associated with abnormal systemic venous return; at the same time, modified mitral valve replacement was performed for mitral regurgitation. The right atrium, tricuspid valve and right ventricle were all extremely dimunitive. The diameter of the tricuspid valve was 50% of normal and the volume of the right ventricle was 8.6% of normal. In addition, there were severe subpumonary stenosis, a restrictive ventricular septal defect (VSD) and an atrial septal defect (ASD). The bilateral superior venae cavae (SVCs) and the hepatic vein drained to the left atrium, and the inferior vena cava was infrahepatically interrupted with a hemiazygos connection to the left superior vena cava. At the operation, each SVC was anastomosed end-to-side to each branch of the pulmonary artery (PA). The restrictive ventricular septal defect and stenotic subpulmonary lesion were left. The diameter of the ASD was reduced from 12 mm to 7 mm. The main PA was neither divided nor banded. The pulsatile blood flow from the left heart to the PA was regurated by a native restrictive VSD and stenotic subpulmonary lesion, and that from the right heart via the ASD was limited by reducing the size of the ASD. These described anatomic arrangements produced adequate antegrade pulsatile flow in the PA, which might prevent the development of pulmonary arteriovenous fistulae and, besides permit transfer of drainage of the hepatic vein from the left to the right atrium via the ASD in future.

  16. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    PubMed

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  17. Liver transplantation in an adult with adenomatosis and congenital absence of the portal vein: a case report.

    PubMed

    Gordon-Burroughs, S; Balogh, J; Weiner, M A; Monsour, H P; Schwartz, M R; Gaber, A O; Ghobrial, R M

    2014-09-01

    Congenital absence of the portal vein (CAPV) is a rare congenital anomaly in which the superior mesenteric veins (SMV) and splenic veins converge and bypass the liver, effectively draining directly into the systemic venous circulation via the inferior vena cava (IVC), or alternatively the renal or iliac vein, creating a native portosystemic shunt. Portosystemic shunting results in clinical manifestations of hepatic encephalopathy as well as a predisposition to focal nodular hyperplasia and tumors, including adenomas, hepatoblastoma, and hepatocellular carcinoma (HCC), by the disruption of enterohepatic blood flow. Historically, CAPV has been thought to be a rare condition found mainly at autopsy, however, in recent years due to advances in radiological techniques, CAPV detection has increased. Herein we describe a patient with known CAPV who initially underwent hepatic resection for HCC. During surveillance, additional masses were discovered and were identified as recurrent HCC. Unfortunately, this patient was not a candidate for further resection or locoregional therapy. We demonstrate that transplantation is a challenging but technically viable option for treatment of HCC complicating adenomatosis-associated CAPV. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Behavioural consequences of IVC cages on male and female C57BL/6J mice.

    PubMed

    Logge, W; Kingham, J; Karl, T

    2013-05-01

    Recent developments in the technology to breed and house laboratory rodents for medical research has produced individually ventilated cage (IVC) systems. These IVC systems produce a cage environment significantly different to conventional cages. As it is not known in detail whether housing mice in IVCs impacts on their baseline and drug-induced behaviours compared to mice of conventional filter-top cages a comprehensive multi-tiered phenotyping strategy was used to test the behavioural consequences of IVC housing in male and female C57BL/6JArc mice. IVC had anxiety-like effects in the elevated plus maze, which were more pronounced in female mice whereas cognition and locomotion of all test mice were not modified by IVC housing. Mice raised in IVC cage systems were socially more active than mice of filter-top systems. Furthermore, males raised in IVC exhibited an increased sensitivity to the locomotor-stimulating effects of acute MK-801 treatment compared to males in conventional cages. In summary, this is the first study revealing the longer-term effects of IVC housing on social behaviours and the locomotor response to an acute MK-801 challenge. In conclusion, researchers upgrading their holding facilities to IVC housing may encounter a shift in experimental outcomes (e.g. post pharmacological challenges) and the behavioural phenotype of test mice. Furthermore, differences between the housing conditions of breeding facilities and test facilities must carefully be considered. Finally, researchers should clarify in detail the type of housing test animals have been exposed to when publishing experimental animal research data. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  19. Repeatable noninvasive measurement of mouse myocardial glucose uptake with 18F-FDG: evaluation of tracer kinetics in a type 1 diabetes model.

    PubMed

    Thorn, Stephanie L; deKemp, Robert A; Dumouchel, Tyler; Klein, Ran; Renaud, Jennifer M; Wells, R Glenn; Gollob, Michael H; Beanlands, Rob S; DaSilva, Jean N

    2013-09-01

    A noninvasive and repeatable method for assessing mouse myocardial glucose uptake with (18)F-FDG PET and Patlak kinetic analysis was systematically assessed using the vena cava image-derived blood input function (IDIF). Contrast CT and computer modeling was used to determine the vena cava recovery coefficient. Vena cava IDIF (n = 7) was compared with the left ventricular cavity IDIF, with blood and liver activity measured ex vivo at 60 min. The test-retest repeatability (n = 9) of Patlak influx constant K(i) at 10-40 min was assessed quantitatively using Bland-Altman analysis. Myocardial glucose uptake rates (rMGU) using the vena cava IDIF were calculated at baseline (n = 8), after induction of type 1 diabetes (streptozotocin [50 mg/kg] intraperitoneally, 5 d), and after acute insulin stimulation (0.08 mU/kg of body weight intraperitoneally). These changes were analyzed with a standardized uptake value calculation at 20 and 40 min after injection to correlate to the Patlak time interval. The proximal mouse vena cava diameter was 2.54 ± 0.30 mm. The estimated recovery coefficient, calculated using nonlinear image reconstruction, decreased from 0.76 initially (time 0 to peak activity) to 0.61 for the duration of the scan. There was a 17% difference in the image-derived vena cava blood activity at 60 min, compared with the ex vivo blood activity measured in the γ-counter. The coefficient of variability for Patlak K(i) values between mice was found to be 23% with the proposed method, compared with 51% when using the left ventricular cavity IDIF (P < 0.05). No significant bias in K(i) was found between repeated scans with a coefficient of repeatability of 0.16 mL/min/g. Calculated rMGU values were reduced by 60% in type 1 diabetic mice from baseline scans (P < 0.03, ANOVA), with a subsequent increase of 40% to a level not significantly different from baseline after acute insulin treatment. These results were confirmed with a standardized uptake value measured at 20 and 40 min. The mouse vena cava IDIF provides repeatable assessment of the blood time-activity curve for Patlak kinetic modeling of rMGU. An expected significant reduction in myocardial glucose uptake was demonstrated in a type 1 diabetic mouse model, with significant recovery after acute insulin treatment, using a mouse vena cava IDIF approach.

  20. Liver hanging maneuver for right hemiliver in situ donation – anatomical considerations

    PubMed Central

    Gadžijev, E.M.; Ravnik, D.; Hribernik, M.

    2006-01-01

    Background. An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4–6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. Materials and methods. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. Results. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7±3.4 mm and to the entrance of segment 9 veins was 5.0±0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7±2.3 mm (range 2–15 mm). Discussion. The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%). PMID:18333236

  1. Incarvine C suppresses proliferation and vasculogenic mimicry of hepatocellular carcinoma cells via targeting ROCK inhibition.

    PubMed

    Zhang, Ji-Gang; Zhang, Dan-Dan; Wu, Xin; Wang, Yu-Zhu; Gu, Sheng-Ying; Zhu, Guan-Hua; Li, Xiao-Yu; Li, Qin; Liu, Gao-Lin

    2015-10-28

    Studies have described vasculogenic mimicry (VM) as an alternative circulatory system to blood vessels in multiple malignant tumor types, including hepatocellular carcinoma (HCC). In the current study, we aimed to seek novel and more efficient treatment strategies by targeting VM and explore the underlying mechanisms in HCC cells. Cell counting kit-8 (CCK-8) assay and colony survival assay were performed to explore the inhibitory effect of incarvine C (IVC) on human cancer cell proliferation. Flow cytometry was performed to analyze the cell cycle distribution after DNA staining and cell apoptosis by the Annexin V-PE and 7-AAD assay. The effect of IVC on Rho-associated, coiled-coil-containing protein kinase (ROCK) was determined by western blotting and stress fiber formation assay. The inhibitory role of IVC on MHCC97H cell VM formation was determined by formation of tubular network structures on Matrigel in vitro, real time-qPCR, confocal microscopy and western blotting techniques. We explored an anti-metastatic HCC agent, IVC, derived from traditional Chinese medicinal herbs, and found that IVC dose-dependently inhibited the growth of MHCC97H cells. IVC induced MHCC97H cell cycle arrest at G1 transition, which was associated with cyclin-dependent kinase 2 (CDK-2)/cyclin-E1 degradation and p21/p53 up-regulation. In addition, IVC induced apoptotic death of MHCC97H cells. Furthermore, IVC strongly suppressed the phosphorylation of the ROCK substrate myosin phosphatase target subunit-1 (MYPT-1) and ROCK-mediated actin fiber formation. Finally, IVC inhibited cell-dominant tube formation in vitro, which was accompanied with the down-regulation of VM-key factors as detected by real time-qPCR and immunofluorescence. Taken together, the effective inhibitory effect of IVC on MHCC97H cell proliferation and neovascularization was associated with ROCK inhibition, suggesting that IVC may be a new potential drug candidate for the treatment of HCC.

  2. Accuracy of the caval index and the expiratory diameter of the inferior vena cava for the diagnosis of dehydration in elderly.

    PubMed

    Orso, Daniele; Guglielmo, Nicola; Federici, Nicola; Cugini, Francesco; Ban, Alessio; Mearelli, Filippo; Copetti, Roberto

    2016-09-01

    Dehydration is a very common condition among elderly people. Till date there is not yet a fast and easy method to determine a state of dehydration in the emergency department. In the literature there are some exploratory studies that have tried to establish the relationship between some widely used laboratory values and ultrasound for the purpose of diagnosing dehydration. The primary aim of this study is to verify the correlation between two measures derived by ultrasound (caval index and expiratory diameter of inferior vena cava) and blood urea nitrogen (BUN)/creatinine ratio. The relationship between vital signs and BUN/creatinine ratio has also been explored. An observational cohort study of patients aged 70 years or more, all examined in our ED. The population was divided on the basis of the BUN/creatinine ratio greater or lower than 20. A total of 270 patients have been considered. No vital sign correlated with an increased BUN/creatinine ratio. Both the diameter of the inferior vena cava in expiratory and the percentage of its collapsibility in inspiratory (caval index) have revealed a correlation with a BUN/creatinine ratio greater than 20. Areas under the curve are, respectively, 76 % (95 % CI 70-82) and 80 % (95 % CI 75-86). Sensitivity, specificity, positive predictive value and negative predictive value are, respectively, 85.5 % (95 % CI 79.4-90.4); 100 % (95 % CI 97-100); 100 % (95 % CI 97.5-100); 82.9 % (95 % CI 75.9-88.7) and 99.3 % (95 % CI 96.3-99.9); 100 % (95 % CI 97-100); 100 % (95 % CI 97.5-100); 99.2 % (95 % CI 95.6-99.9). Ultrasound has proved to be useful to diagnose dehydration in elderly people while in the emergency department. Vice versa the vital signs have shown to be unrelated to the hydration state of elderly patients.

  3. Inferior sinus venosus defects: anatomic features and echocardiographic correlates.

    PubMed

    Plymale, Jennifer; Kolinski, Kellen; Frommelt, Peter; Bartz, Peter; Tweddell, James; Earing, Michael G

    2013-02-01

    Inferior sinus venosus defects (SVDs) are rare imperfections located in the inferior portion of the atrial septum, leading to an overriding inferior vena cava (IVC) and an interatrial connection. These defects have increased risk of anomalous pulmonary venous return (PAPVR) and often are confused with secundum atrial septal defects (ASDs) with inferior extension. The authors sought to review their experience with inferior SVDs and to establish at their institution an echocardiographic definition that differentiates inferior SVDs from secundum ASDs with inferior extension. The study identified 161 patients 1.5 to 32 years of age who had undergone repair of a secundum ASD with inferior extension or inferior SVD over the preceding 10 years. All surgical notes, preoperative transthoracic echocardiograms (TTEs), and preoperative transesophageal echocardiograms (TEEs) were reviewed. Based on the surgical notes, 147 patients were classified as having a secundum ASD (147/161, 91 %) and 14 patients (9 %) as having an inferior SVD. The study identified PAPVR in 7 % (1/14) of the patients with inferior SVDs and 3.5 % (5/14) of the patients with secundum ASDs. Surgical diagnosis and preoperative TTE correlated for 143 (89 %) of the 161 patients. Using a strict anatomic and echocardiographic definition with a blinded observer, the majority of the defects (14/18, 78 %) were reclassified correctly after review of their TTE images, and 100 % of the defects were correctly reclassified after TEE image review. Accurate diagnosis of inferior SVDs remains challenging. The data from this study demonstrate that use of a strict anatomic and echocardiographic definition (a defect that originates in the mouth of the IVC and continues into the inferoposterior border of the left atrium, leaving no residual atrial septal tissue at the inferior margin) allows for accurate differentiation between secundum ASDs with inferior extension and inferior SVDs. This differentiation is extremely important in planning for surgical versus device closure of these rare defects.

  4. Prophylactic Residual Aneurysmal Sac Embolization with Expandable Hydrogel Embolic Devices for Endoleak Prevention: Preliminary Study in Dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiraki, Takao; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Uchida, Barry T.

    2005-05-15

    Objective. To explore the feasibility and efficacy of residual aneurysmal sac (RAS) embolization with the expandable hydrogel embolic device (EHED) in prevention of endoleaks in a surgically created and endoluminally treated abdominal aortic aneurysm (AAA). Methods. In eight dogs, an AAA was created by means of side-to-side anastomosis between the infrarenal abdominal aorta and inferior vena cava (IVC) with ligation of the IVC above and below the anastomotic end, followed by deployment of an endograft with holes. The RAS was then embolized with the EHED. One animal was killed immediately after RAS embolization and one animal died 12 hr aftermore » the procedure. Follow-up aortograms were obtained in six animals after 1 day (1 animal), 2 weeks and 6 months (1 animal), and 8 weeks (4 animals). Results. Four animals had no endoleaks on the follow-up aortograms. The remaining two animals with incomplete RAS embolization had moderate type III endoleaks. Type I or II endoleaks were not seen in any animals. Complications included RAS wall penetration by the devices with platinum wires in two animals (nos. 1 and 2), device migration into an aortic circulation through the endograft holes in two animals (nos. 2 and 3) or through distal interstices between the aortic wall and endograft in one animal (no. 8), aortic occlusion in three animals (nos. 3, 7, and 8), and RAS rupture in one animal (no. 7). Histologic examination showed expanded hydrogels occupying the RAS with associated mature or immature organized thrombus, fibrinous thrombus, or degenerate blood cells. Conclusion. RAS embolization was feasible with the EHED, although additional modifications to the device are required to avoid complications. Angiographic and histologic results suggested that RAS embolization with the EHED may help in the prevention of endoleaks.« less

  5. A hybrid segmentation method for partitioning the liver based on 4D DCE-MR images

    NASA Astrophysics Data System (ADS)

    Zhang, Tian; Wu, Zhiyi; Runge, Jurgen H.; Lavini, Cristina; Stoker, Jaap; van Gulik, Thomas; Cieslak, Kasia P.; van Vliet, Lucas J.; Vos, Frans M.

    2018-03-01

    The Couinaud classification of hepatic anatomy partitions the liver into eight functionally independent segments. Detection and segmentation of the hepatic vein (HV), portal vein (PV) and inferior vena cava (IVC) plays an important role in the subsequent delineation of the liver segments. To facilitate pharmacokinetic modeling of the liver based on the same data, a 4D DCE-MR scan protocol was selected. This yields images with high temporal resolution but low spatial resolution. Since the liver's vasculature consists of many tiny branches, segmentation of these images is challenging. The proposed framework starts with registration of the 4D DCE-MRI series followed by region growing from manually annotated seeds in the main branches of key blood vessels in the liver. It calculates the Pearson correlation between the time intensity curves (TICs) of a seed and all voxels. A maximum correlation map for each vessel is obtained by combining the correlation maps for all branches of the same vessel through a maximum selection per voxel. The maximum correlation map is incorporated in a level set scheme to individually delineate the main vessels. Subsequently, the eight liver segments are segmented based on three vertical intersecting planes fit through the three skeleton branches of HV and IVC's center of mass as well as a horizontal plane fit through the skeleton of PV. Our segmentation regarding delineation of the vessels is more accurate than the results of two state-of-the-art techniques on five subjects in terms of the average symmetric surface distance (ASSD) and modified Hausdorff distance (MHD). Furthermore, the proposed liver partitioning achieves large overlap with manual reference segmentations (expressed in Dice Coefficient) in all but a small minority of segments (mean values between 87% and 94% for segments 2-8). The lower mean overlap for segment 1 (72%) is due to the limited spatial resolution of our DCE-MR scan protocol.

  6. Statistical Shape Modeling for Cavopulmonary Assist Device Development: Variability of Vascular Graft Geometry and Implications for Hemodynamics.

    PubMed

    Bruse, Jan L; Giusti, Giuliano; Baker, Catriona; Cervi, Elena; Hsia, Tain-Yen; Taylor, Andrew M; Schievano, Silvia

    2017-06-01

    Patients born with a single functional ventricle typically undergo three-staged surgical palliation in the first years of life, with the last stage realizing a cross-like total cavopulmonary connection (TCPC) of superior and inferior vena cavas (SVC and IVC) with both left and right pulmonary arteries, allowing all deoxygenated blood to flow passively back to the lungs (Fontan circulation). Even though within the past decades more patients survive into adulthood, the connection comes at the prize of deficiencies such as chronic systemic venous hypertension and low cardiac output, which ultimately may lead to Fontan failure. Many studies have suggested that the TCPC's inherent insufficiencies might be addressed by adding a cavopulmonary assist device (CPAD) to provide the necessary pressure boost. While many device concepts are being explored, few take into account the complex cardiac anatomy typically associated with TCPCs. In this study, we focus on the extra cardiac conduit vascular graft connecting IVC and pulmonary arteries as one possible landing zone for a CPAD and describe its geometric variability in a cohort of 18 patients that had their TCPC realized with a 20mm vascular graft. We report traditional morphometric parameters and apply statistical shape modeling to determine the main contributors of graft shape variability. Such information may prove useful when designing CPADs that are adapted to the challenging anatomical boundaries in Fontan patients. We further compute the anatomical mean 3D graft shape (template graft) as a representative of key shape features of our cohort and prove this template graft to be a significantly better approximation of population and individual patient's hemodynamics than a commonly used simplified tube geometry. We therefore conclude that statistical shape modeling results can provide better models of geometric and hemodynamic boundary conditions associated with complex cardiac anatomy, which in turn may impact on improved cardiac device development.

  7. Sulci of the liver found after death: Their nature and potential teaching value.

    PubMed

    Macchi, V; Porzionato, A; Stecco, C; Parenti, A; Newell, R L M; De Caro, R

    2013-07-01

    Accessory sulci of the liver are more commonly found after death than in life, raising questions as to their causation and possible classification. We have analyzed a group of 180 livers sampled from un-embalmed (96) and embalmed cadavers (84). In un-embalmed cadavers, no accessory sulci were found on the diaphragmatic surface in 58 cases. Diaphragmatic sulci were found in the right lobe of 38 livers. When removed from the abdominal cavity and placed flat on the examination table (the "bench position") all 58 livers without sulci appreciable in the abdominal cavity showed the appearance of two sulci. The first ran from the right side of the inferior vena cava (IVC), curving anteriorly to the inferior border of the liver, at a point midway between the right extremity of the inferior border and the gallbladder fossa, concave towards the left. The second sulcus ran from the left side of the IVC, curving anteriorly to reach the inferior border of the liver at the level of the gallbladder fossa, concave towards the right. With progressive side-to-side manual compression, the sulci on the diaphragmatic surface become more evident. Division of the hepatic parenchyma along the two sulci exposed the right and middle hepatic veins respectively in more than 90% of cases. In embalmed cadavers, 24 livers showed antero-posterior sulci in the superior surface, visible and palpable on the liver examined in situ. When the livers with sulci had been removed from the abdomen for further examination, the appearance of the superior surface did not change. In a removed liver, accessory sulci can be divided into true, "diaphragmatic," sulci and "false" sulci due to the position of the free liver on the examination table. The "false" sulci may be considered as further morphological evidence of the functional anatomical division of the liver. Their demonstration may also be useful in teaching its topographical and surgical anatomy. Copyright © 2012 Wiley Periodicals, Inc.

  8. Percutaneous Transjugular Direct Porto-caval Shunt in Patients with Budd-Chiari Syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quateen, A.; Pech, M.; Berg, T.

    The purpose of the study was to evaluate the feasibility and effectiveness of direct porto-caval shunts in patients with Budd-Chiari syndrome (BCS) in whom there is no access to the hepatic veins during transjugular intrahepatic portosystemic shunt (TIPSS). We included six consecutive patients with fulminant/acute Budd-Chiari syndrome (mean age: 35 years) in whom a conventional TIPSS was not possible due to inaccessible hepatic veins. We performed a direct porto-caval shunt via a transhepatic approach. Patients were followed up by means of clinical examination, laboratory investigations, and Doppler ultrasound. TIPSS implantation from the inferior vena cava (IVC) was successful in allmore » six patients (100%). The median transhepatic shunt length was 9 cm (8-10 cm). No procedure-related complications were observed in our patients. Early shunt occlusion occurred in three out of six patients (50%). In all three of these patients, the stent used to stabilize the shunt ended 1-2 cm before reaching the IVC. All occlusions were successfully recanalized. One of these patients developed recurrent early shunt as well as mesenteric and splenic vein occlusions. She died 7 days after TIPSS placement due to an unmanageable coagulation disorder. The remaining five patients were followed up by planned clinical examination and laboratory investigations (mean follow-up time was 15 months; patient 1 was followed up for 13 months, patient 2 for 14 months, patient 3 for 15 months, and patients 4 and 5 for 16 months) and all displayed a complete and durable resolution of liver failure and ascites without reintervention. In patients with acute liver failure originating from BCS and inaccessible hepatic veins, a direct transhepatic porto-caval shunt can be performed safely and effectively under ultrasound guidance. Future studies in larger patient groups should investigate if the patency of transcaval TIPSS with long transhepatic shunt segments is similar compared to conventional TIPSS via the hepatic vein.« less

  9. Intravitreal Conbercept Injection with and without Grid Laser Photocoagulation in the Treatment of Diffuse Diabetic Macular Edema in Real-Life Clinical Practice.

    PubMed

    Xu, Yule; Rong, Ao; Bi, Yanlong; Xu, Wei

    2016-01-01

    Purpose . To evaluate the efficacy of intravitreal conbercept (IVC) plus modified grid laser photocoagulation (MGP) versus IVC alone for treatment of diffuse diabetic macular edema (DDME). Methods. In this retrospective study, 51 DDME patients were treated with either IVC alone (IVC group) or IVC plus MGP (combined group) with 12 months of follow-up. The clinical records of those patients were reviewed. Results. 26 patients (31 eyes) received IVC alone and 25 patients (30 eyes) received combined therapy. At month 12, the mean best-corrected visual acuity (BCVA) letter score improvement was 9.1 ± 4.5 and 7.5 ± 4.2 in the IVC group and the combined group and the mean central retinal thickness (CRT) reduction was 145.1 ± 69.9  μ m and 168.5 ± 53.6  μ m, respectively. There was no statistically significant difference of improvement in BCVA ( P = 0.164) and decrease in CRT ( P = 0.149) between the two groups. The mean number of injections delivered was significantly higher ( P < 0.001) in the IVC group (5.6 ± 0.8 per eye) than in the combined group (3.3 ± 1.2 per eye). Conclusions . IVC alone or combined with MGP appeared to be effective for treatment of DDME, achieving the similar clinical efficacy. Moreover, MGP helps to reduce the number of injections.

  10. Cyanoacrylate tissue adhesives - effective securement technique for intravascular catheters: in vitro testing of safety and feasibility.

    PubMed

    Simonova, G; Rickard, C M; Dunster, K R; Smyth, D J; McMillan, D; Fraser, J F

    2012-05-01

    Partial or complete dislodgement of intravascular catheters remains a significant problem in hospitals despite current securement methods. Cyanoacrylate tissue adhesives (TA) are used to close skin wounds as an alternative to sutures. These adhesives have high mechanical strength and can remain in situ for several days. This study investigated in vitro use of TAs in securing intravascular catheters (IVC). We compared two adhesives for interaction with IVC material, comparing skin glues with current securement methods in terms of their ability to prevent IVC dislodgement and inhibit microbial growth. Two TAs (Dermabond, Ethicon Inc. and Histoacryl, B. Braun) and three removal agents (Remove™, paraffin and acetone) were tested for interaction with IVC material by use of tensile testing. TAs were also compared against two polyurethane (standard and bordered) dressings (Tegaderm™ 1624 and 1633, 3M Australia Pty Ltd) and an external stabilisation device (Statlock, Bard Medical, Covington) against control (unsecured IVCs) for ability to prevent pull-out of 16 G peripheral IVCs from newborn fresh porcine skin. Agar media containing pH-sensitive dye was used to assess antimicrobial properties of TAs and polyurethane dressings to inhibit growth of Staphylococcus aureus and Staphylococcus epidermidis. Neither TA weakened the IVCs (P >0.05). Of removal agents, only acetone was associated with a significant decrease in IVC strength (P <0.05). Both TAs and Statlock significantly increased the pull-out force (P <0.01). TA was quick and easy to apply to IVCs, with no irritation or skin damage noted on removal and no bacterial colony growth under either TA.

  11. Worldwide human papillomavirus genotype attribution in over 2000 cases of intraepithelial and invasive lesions of the vulva.

    PubMed

    de Sanjosé, Silvia; Alemany, Laia; Ordi, Jaume; Tous, Sara; Alejo, Maria; Bigby, Susan M; Joura, Elmar Armin; Maldonado, Paula; Laco, Jan; Bravo, Ignacio G; Vidal, August; Guimerà, Núria; Cross, Paul; Wain, Gerard V; Petry, Karl Ulrich; Mariani, Luciano; Bergeron, Christine; Mandys, Václav; Sica, Adela Rosa; Félix, Ana; Usubutun, Alp; Seoud, Muhieddine; Hernández-Suárez, Gustavo; Nowakowski, Andrzej Marcin; Wilson, Godfrey; Dalstein, Veronique; Hampl, Monika; Kasamatsu, Elena Sachiko; Lombardi, Luis Estuardo; Tinoco, Leopoldo; Alvarado-Cabrero, Isabel; Perrotta, Myriam; Bhatla, Neerja; Agorastos, Theodoros; Lynch, Charles F; Goodman, Marc T; Shin, Hai-Rim; Viarheichyk, Halina; Jach, Robert; Cruz, M O L Eugenia; Velasco, Julio; Molina, Carla; Bornstein, Jacob; Ferrera, Annabelle; Domingo, Efren Javier; Chou, Cheng-Yang; Banjo, Adekunbiola F; Castellsagué, Xavier; Pawlita, Michael; Lloveras, Belén; Quint, Wim G V; Muñoz, Nubia; Bosch, F Xavier

    2013-11-01

    Human papillomavirus (HPV) contribution in vulvar intraepithelial lesions (VIN) and invasive vulvar cancer (IVC) is not clearly established. This study provides novel data on HPV markers in a large series of VIN and IVC lesions. Histologically confirmed VIN and IVC from 39 countries were assembled at the Catalan Institute of Oncology (ICO). HPV-DNA detection was done by polymerase chain reaction using SPF-10 broad-spectrum primers and genotyping by reverse hybridisation line probe assay (LiPA25) (version 1). IVC cases were tested for p16(INK4a) by immunohistochemistry (CINtec histology kit, ROCHE). An IVC was considered HPV driven if both HPV-DNA and p16(INK4a) overexpression were observed simultaneously. Data analyses included algorithms allocating multiple infections to calculate type-specific contribution and logistic regression models to estimate adjusted prevalence (AP) and its 95% confidence intervals (CI). Of 2296 cases, 587 were VIN and 1709 IVC. HPV-DNA was detected in 86.7% and 28.6% of the cases respectively. Amongst IVC cases, 25.1% were both HPV-DNA and p16(INK4a) positive. IVC cases were largely keratinising squamous cell carcinoma (KSCC) (N=1234). Overall prevalence of HPV related IVC cases was highest in younger women for any histological subtype. SCC with warty or basaloid features (SCC_WB) (N=326) were more likely to be HPV and p16(INK4a) positive (AP=69.5%, CI=63.6-74.8) versus KSCC (AP=11.5%, CI=9.7-13.5). HPV 16 was the commonest type (72.5%) followed by HPV 33 (6.5%) and HPV 18 (4.6%). Enrichment from VIN to IVC was significantly high for HPV 45 (8.5-fold). Combined data from HPV-DNA and p16(INK4a) testing are likely to represent a closer estimate of the real fraction of IVC induced by HPV. Our results indicate that HPV contribution in invasive vulvar cancer has probably been overestimated. HPV 16 remains the major player worldwide. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Individually ventilated cages cause chronic low-grade hypoxia impacting mice hematologically and behaviorally

    PubMed Central

    York, Jason M.; McDaniel, Allison W.; Blevins, Neil A.; Guillet, Riley R.; Allison, Sarah O.; Cengel, Keith A.; Freund, Gregory G.

    2012-01-01

    Use of individually ventilated caging (IVC) systems for mouse-based laboratory investigation has dramatically increased. We found that without mice present, intra-cage oxygen concentration was comparable (21%) between IVC housing and ambient environment caging (AEC) that used wire top lids. However, when mice were housed 4-to-a-cage for 1 week, intra-cage oxygen dropped to 20.5% in IVC housing as compared to 21% for AEC housing. IVC intra-cage humidity was also elevated relative to AEC housing. Mice raised in IVC housing as compared to mice raised in AEC housing had higher RBC mass, hematocrit and hemoglobin concentrations. They also had elevated platelet counts but lower white blood cell counts. IVC mice relative to AEC mice had increased saccharin preference and increased fluid consumption but similar locomotion, food intake, social exploration and novel object recognition when tested in an AEC environment. Taken together, these data indicate that ventilated caging systems can have a 0.5% reduction from ambient oxygen concentration that is coupled to mouse red blood cell indices indicative of chronic exposure to a hypoxia. Importantly, IVC housing can impact behavioral testing for depressive-like behavior. PMID:22561683

  13. Relative incidence of phlebitis associated with peripheral intravenous catheters in the lower versus upper extremities.

    PubMed

    Benaya, A; Schwartz, Y; Kory, R; Yinnon, A M; Ben-Chetrit, E

    2015-05-01

    Peripheral venous access in elderly, hospitalized patients is often challenging. The usual alternative is insertion of a central venous catheter, with associated risk for complications. The purpose of this investigation was to determine the relative incidence of phlebitis secondary to lower as compared to upper extremity intravenous catheters (IVCs) and associated risk factors. A non-randomized, observational, cohort-controlled study was carried out. Consecutive patients receiving a lower extremity IVC were enrolled and compared with patients receiving an upper extremity IVC. Patients were followed from insertion until removal of the IVC. The major endpoint was phlebitis. The incidence of phlebitis secondary to upper extremity IVCs was 3/50 (6 %) compared to 5/53 (9.4 %) in lower extremity IVCs (χ(2) Yates = 0.08, p = 0.776). Age, gender, obesity, diabetes mellitus, site (arm versus leg, left versus right), and size of needle were not found to be risk factors for phlebitis according to univariate analysis. None of the patients developed bloodstream infection. In elderly patients with poor venous access, lower extremity IVCs are a reasonable and low-risk alternative to central venous catheters.

  14. A 27-Year Experience With Surgical Treatment of Budd-Chiari Syndrome

    PubMed Central

    Orloff, Marshall J.; Daily, Pat O.; Orloff, Susan L.; Girard, Barbara; Orloff, Mark S.

    2000-01-01

    Objective To determine the effects of surgical portal decompression in Budd-Chiari syndrome (BCS) on survival, quality of life, shunt patency, liver function, portal hemodynamics, and hepatic morphology during periods ranging from 3.5 to 27 years. Summary Background Data Experiments in the authors’ laboratory showed that surgical portal decompression reversed the deleterious effects of BCS on the liver. This study was aimed at determining whether similar benefit could be obtained in patients with BCS. Methods From 1972 to 1999, the authors conducted prospective studies of the treatment of 60 patients with BCS who were divided into three groups: the first had occlusion confined to the hepatic veins treated by direct side-to-side portacaval shunt (SSPCS); the second had occlusion involving the inferior vena cava (IVC) treated by a portal decompressive procedure that bypassed the obstructed IVC; and the third group, who had advanced cirrhosis and hepatic decompensation and were referred too late for treatment by portal decompression, required orthotopic liver transplantation. Results In the 32 patients with BCS resulting from hepatic vein occlusion alone, SSPCS had a surgical death rate of 3%, and 94% of the patients were alive 3.5 to 27 years after surgery. All 31 survivors remained free of ascites and almost all had normal liver function. No patient with a patent shunt had encephalopathy. The SSPCS remained patent in all but one patient. Liver biopsies showed no evidence of congestion or necrosis, and 48% of the biopsies were diagnosed as normal. Mesoatrial shunt was performed in eight patients with BCS caused by IVC thrombosis. All patients survived surgery, but five subsequently developed thrombosis of the synthetic graft and died. Because of the poor results, mesoatrial shunt was abandoned. Instead, a high-flow combination shunt was introduced, consisting of SSPCS combined with a cavoatrial shunt (CAS) through a Gore-Tex graft. There were no surgical or long-term deaths among 10 patients who underwent combined SSPCS and CAS, and the shunts functioned effectively during 4 to 16 years of follow-up. Ten patients with advanced cirrhosis were referred too late to benefit from surgical portal decompression, and they were approved and listed for orthotopic liver transplantation. Three patients died of liver failure while awaiting a transplant, and four patients died after the transplant. The 1- and 5-year survival rates were 40% and 30%, respectively. Conclusions SSPCS in BCS with hepatic vein occlusion alone results in reversal of liver damage, correction of hemodynamic disturbances, prolonged survival, and good quality of life when performed early in the course of BCS. Similarly good results are obtained with combined SSPCS and CAS in patients with BCS resulting from IVC occlusion. In contrast, mesoatrial shunt has been discontinued in the authors’ program because of an unacceptable incidence of graft thrombosis and death. In patients with advanced cirrhosis from long-standing, untreated BCS, orthotopic liver transplantation is the only hope of relief and results in the salvage of some patients. The key to long survival in BCS is prompt diagnosis and treatment by portal decompression. PMID:10973384

  15. Effect of Antithrombotic Agents on the Patency of PTFE-Covered Stents in the Inferior Vena Cava: An Experimental Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makutani, Shiro; Kichikawa, Kimihiko; Uchida, Hideo

    Purpose: To evaluate the efficacy of antithrombotic agents in the prevention of stenosis of polytetrafluoroethylene (PTFE)-covered stents in the venous system. Methods: Spiral Z stents covered with PTFE (PTFE-covered stents) were placed in the inferior vena cava (IVC) of 34 dogs. Nineteen dogs, used as a control group, were sacrificed at 2, 4, and 12 weeks. Fifteen dogs, previously given antithrombotic agents [cilostazol (n= 5), warfarin potassium (n= 5), cilostazol plus warfarin potassium (n= 5)] were sacrificed at 4 weeks, and then examined angiographically and histopathologically. The effect of the antithrombotic agents was compared between groups. Results: The patency ratemore » of the antithrombotic agent group was 93% (14/15), which was higher than the control group rate of 63% (12/19). The mean stenosis rate of the patent stent at both ends and at the midportion was lower at 4 weeks in the antithrombotic agent group than in the control group. In particular, the mean stenosis rate in the cilostazol plus warfarin potassium group was significantly lower than the control group (Tukey's test, p < 0.05). The mean neointimal thickness of the patent stent at both ends and at the midportion was thinner at 4 weeks in the antithrombotic agent group than in the control group. In particular, the thickness of the neointima in the cilostazol plus warfarin potassium group was significantly decreased when compared with the control group (Tukey's test p < 0.05). At 4 weeks, endothelialization in the antithrombotic agent group tended to be almost identical to that in the control group. Conclusion: The present study suggests that administration of an antithrombotic agent is an effective way of preventing the stenosis induced by a neointimal thickening of PTFE-covered stents in the venous system.« less

  16. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis.

    PubMed

    Liu, Ning; Wang, Zhen; Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18-45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis.

  17. Renal Cell Carcinoma Associated with Xp11.2 Translocation/TFE3 Gene Fusions: Clinical Features, Treatments and Prognosis

    PubMed Central

    Gan, Weidong; Xiong, Lei; Miao, Baolei; Chen, Xiancheng; Guo, Hongqian; Li, Dongmei

    2016-01-01

    To investigate the clinical characteristics, treatments and prognosis of renal cell carcinoma associated with Xp11.2 translocation/TFE3 gene fusions (Xp11.2 tRCC), the epidemiological features and treatment results of 34 cases of Xp11.2 tRCC, which were diagnosed by immunohistochemistry staining of TFE3 and fluorescence in situ hybridization at our center, were retrospectively reviewed. The 34 patients included 21 females and 13 males aged 3 to 64 years (median age: 27 years). Four patients were children or adolescents (<18 years of age), and 26 patients were young or middle-aged adults (18–45 years). Radical nephrectomy was performed on 25 patients. Laparoscopic nephron-sparing surgery was performed on 9 patients who presented with an isolated mass with a small diameter (<7 cm) and well-defined boundary on computed tomography imaging. Postoperative staging showed that 25 cases (73.53%) were at stage I/II, while 9 cases (26.47%) were at stage III/IV. All stage I/II patients received a favorable prognosis with a three-year overall survival rate of 100%, including the patients who underwent laparoscopic nephron-sparing surgery. With the exception of 2 children, the other 7 stage III/IV patients died or developed recurrence with a median follow-up of 29 months. On univariate analysis, maximum diameter, adjuvant treatment, TNM stage, lymph node metastasis, inferior vena cava tumor thrombosis and tumor boundary were identified as statistically significant factors impacting survival (P<0.05). Multivariate analysis indicated that TNM stage and inferior vena cava tumor thrombosis were independent prognostic factors (P<0.05). In conclusion, Xp11.2 tRCC is a rare subtype of renal cell carcinoma that mainly occurs in young females. Nephron-sparing surgery was confirmed effective preliminarily in the treatment of small Xp11.2 tRCCs with clear rims. Advanced TNM stage and inferior vena cava tumor thrombosis were associated with poor prognosis. PMID:27893792

  18. 22 CFR 121.5 - Apparatus and devices under Category IV(c).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Apparatus and devices under Category IV(c). 121... UNITED STATES MUNITIONS LIST Enumeration of Articles § 121.5 Apparatus and devices under Category IV(c... units, bomb ejectors, torpedo tubes, torpedo and guided missile boosters, guidance systems equipment and...

  19. Gefitinib in Treating Patients With Metastatic or Unresectable Head and Neck Cancer or Non-Small Cell Lung Cancer

    ClinicalTrials.gov

    2013-01-11

    Anaplastic Thyroid Cancer; Insular Thyroid Cancer; Metastatic Parathyroid Cancer; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Recurrent Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Non-small Cell Lung Cancer; Recurrent Parathyroid Cancer; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Thyroid Cancer; Recurrent Verrucous Carcinoma of the Larynx; Stage III Follicular Thyroid Cancer; Stage III Papillary Thyroid Cancer; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Larynx; Stage IIIB Non-small Cell Lung Cancer; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Follicular Thyroid Cancer; Stage IVA Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Papillary Thyroid Cancer; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Follicular Thyroid Cancer; Stage IVB Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Papillary Thyroid Cancer; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Esthesioneuroblastoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Follicular Thyroid Cancer; Stage IVC Inverted Papilloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Midline Lethal Granuloma of the Paranasal Sinus and Nasal Cavity; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Papillary Thyroid Cancer; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Thryoid Gland Nonmedullary Carcinoma; Thyroid Gland Medullary Carcinoma; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  20. High-dose intravenous vitamin C combined with cytotoxic chemotherapy in patients with advanced cancer: a phase I-II clinical trial.

    PubMed

    Hoffer, L John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H

    2015-01-01

    Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Despite IVC's biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC's value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. ClinicalTrials.gov NCT01050621.

  1. Infrahepatic vena cavocavostomy, a modification of the piggyback technique for liver transplantation.

    PubMed

    Khanmoradi, Kamran; Defaria, Werviston; Nishida, Seigo; Levi, David; Kato, Tomoaki; Moon, Jang; Selvaggi, Gennaro; Tzakis, Andreas

    2009-05-01

    We describe our experience with a modification of the piggyback (PB) technique for orthotopic liver transplantation in which the donor infrahepatic vena cava is used as the venous outflow tract. From May 1997 to January 2006, a total of 109 cases using this technique were performed in 101 patients. Collected data included recipient demographics and diagnosis, warm ischemia time, use of venovenous bypass or temporary portacaval shunt and complications related to the venous outflow and graft, and patient survival. Data were compared with the patients undergoing standard PB technique during the same period. The reasons for using the technique were grouped according to whether there was a problem with the recipient hepatic veins or a concern about the length or diameter of the donor suprahepatic vena cava. These included the presence of a transjugular intrahepatic portosystemic shunt (eight cases), retransplantation (22 cases), thin-walled, friable hepatic veins (32 cases), Budd-Chiari syndrome (two cases), domino liver procurement (six cases), reduced or split liver grafts (five cases), and graft inferior vena cava to recipient hepatic veins size discrepancy (34 cases). There was no graft loss. The warm ischemia time was 39.65 minutes compared with 37 minutes in the standard PB group. The long-term graft and patient survival rates were similar in the two groups. Infrahepatic vena cavocavostomy is a useful variation of the standard PB technique.

  2. The morphometric study of l3-L4 and L4-L5 lumbar spine in Asian population using magnetic resonance imaging: feasibility analysis for transpsoas lumbar interbody fusion.

    PubMed

    Yusof, Mohd Imran; Nadarajan, Eswaran; Abdullah, Mohd Shafie

    2014-06-15

    Cross-sectional study on the measurement of relevant magnetic resonance imaging parameters in 100 patients presented for lumbar spine assessment. To determine anatomical position of lumbar plexus and major blood vessels in relation to vertebral body and anterior edge of psoas muscle at L3-L4 and L4-L5 and to define the safe working zone for transpsoas approach for lumbar fusion. Lateral transpsoas lumbar interbody fusion has been shown to be safe and provides alternative for lumbar fusion. However, proximity of neurovascular structures may not allow a safe passage for this procedure in the Asian population. Relevant parameters were measured from axial magnetic resonance images and analyzed, including the psoas muscle and vertebrae endplate diameters, lumbar plexus and psoas muscle distance, lumbar plexus and vertebra body distance, and vena cava to the anterior vertebrae body diameters. The mean anteroposterior diameters of the right and left psoas muscle ranged from 44.0 to 58.6 mm and 44.8 to 54.0 mm, respectively. The mean anteroposterior diameters of vertebra endplate of L3, L4, and L5 were 38.2 mm, 39.3 mm, and 41.4 mm, respectively. The mean distance of posterior border of vena cava from the vertebra body was 4.5 mm at L3-L4 and 14.1 mm at L4-L5. L3-L4 fusion is feasible at both sides in both sexes; however, at L4-L5 level, the procedure is feasible only on the left side. The safe working zone for transpsoas approach to lumbar spine is significantly narrower at L4-L5 in both sexes. Anterior edge of psoas muscle can be used as a reliable guide to locate lumbar plexus within psoas muscle. N/A.

  3. Circulating Tumor DNA in Predicting Outcomes in Patients With Stage IV Head and Neck Cancer or Stage III-IV Non-small Cell Lung Cancer

    ClinicalTrials.gov

    2018-01-12

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage IIIA Non-small Cell Lung Cancer; Stage IIIB Non-small Cell Lung Cancer; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  4. Temsirolimus With or Without Cetuximab in Patients With Recurrent and/or Metastatic Head and Neck Cancer Who Did Not Respond to Previous Therapy

    ClinicalTrials.gov

    2017-02-23

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Major Salivary Gland Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Major Salivary Gland Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Major Salivary Gland Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma

  5. Comparing blastocyst quality and live birth rates of intravaginal culture using INVOcell™ to traditional in vitro incubation in a randomized open-label prospective controlled trial.

    PubMed

    Doody, Kevin J; Broome, E Jason; Doody, Kathleen M

    2016-04-01

    The purpose of this study is to to compare the efficacy of intravaginal culture (IVC) of embryos in INVOcell™ (INVO Bioscience, MA, USA) to traditional in vitro fertilization (IVF) incubators in a laboratory setting using a mild pre-determined stimulation regimen based solely on anti-mullerian hormone (AMH) and body weight with minimal ultrasound monitoring. The primary endpoint examined was total quality blastocysts expressed as a percentage of total oocytes placed in incubation. Secondary endpoints included percentage of quality blastocysts transferred, pregnancy, and live birth rates. In this prospective randomized open-label controlled single-center study, 40 women aged <38 years of age with a body mass index (BMI) of <36 and an AMH of 1-3 ng/mL were randomized prior to trigger to receive either IVC or IVF. Controlled ovarian stimulation was administered with human menopausal gonadotropin (hMG) in a fixed gonadotropin-releasing hormone (GnRH) agonist cycle based solely on AMH and body weight. A single ultrasound-monitoring visit was performed on the 10th day of stimulation. One or two embryos were transferred following 5 days of culture. IVF produced a greater percentage of total quality embryos as compared to IVC (50.6 vs. 30.7 %, p = 0.0007, respectively). There was no significant difference between in IVF and IVC in the percentage of quality blastocysts transferred (97.5 vs. 84.9 %, p = 0.09) or live birth rate (60 % IVF, 55 % IVC). IVF was shown to be superior to IVC in creating quality blastocysts. However, both IVF and IVC produced identical blastocysts for transfer resulting in similar live birth rates. IVC using INVOcell™ is effective and may broaden access to fertility care in selected patient populations by ameliorating the need for a traditional IVF laboratory setting. Further studies will help elucidate the potential physiological, psychological, geographic, and financial impact of IVC on the delivery of fertility care.

  6. Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation

    PubMed Central

    Walker-Samuel, Simon; Davies, Nathan; Halligan, Steve; Lythgoe, Mark F.

    2016-01-01

    Purpose To validate caval subtraction two-dimensional (2D) phase-contrast magnetic resonance (MR) imaging measurements of total liver blood flow (TLBF) and hepatic arterial fraction in an animal model and evaluate consistency and reproducibility in humans. Materials and Methods Approval from the institutional ethical committee for animal care and research ethics was obtained. Fifteen Sprague-Dawley rats underwent 2D phase-contrast MR imaging of the portal vein (PV) and infrahepatic and suprahepatic inferior vena cava (IVC). TLBF and hepatic arterial flow were estimated by subtracting infrahepatic from suprahepatic IVC flow and PV flow from estimated TLBF, respectively. Direct PV transit-time ultrasonography (US) and fluorescent microsphere measurements of hepatic arterial fraction were the standards of reference. Thereafter, consistency of caval subtraction phase-contrast MR imaging–derived TLBF and hepatic arterial flow was assessed in 13 volunteers (mean age, 28.3 years ± 1.4) against directly measured phase-contrast MR imaging PV and proper hepatic arterial inflow; reproducibility was measured after 7 days. Bland-Altman analysis of agreement and coefficient of variation comparisons were undertaken. Results There was good agreement between PV flow measured with phase-contrast MR imaging and that measured with transit-time US (mean difference, −3.5 mL/min/100 g; 95% limits of agreement [LOA], ±61.3 mL/min/100 g). Hepatic arterial fraction obtained with caval subtraction agreed well with those with fluorescent microspheres (mean difference, 4.2%; 95% LOA, ±20.5%). Good consistency was demonstrated between TLBF in humans measured with caval subtraction and direct inflow phase-contrast MR imaging (mean difference, −1.3 mL/min/100 g; 95% LOA, ±23.1 mL/min/100 g). TLBF reproducibility at 7 days was similar between the two methods (95% LOA, ±31.6 mL/min/100 g vs ±29.6 mL/min/100 g). Conclusion Caval subtraction phase-contrast MR imaging is a simple and clinically viable method for measuring TLBF and hepatic arterial flow. Online supplemental material is available for this article. PMID:27171018

  7. Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation.

    PubMed

    Chouhan, Manil D; Mookerjee, Rajeshwar P; Bainbridge, Alan; Walker-Samuel, Simon; Davies, Nathan; Halligan, Steve; Lythgoe, Mark F; Taylor, Stuart A

    2016-09-01

    Purpose To validate caval subtraction two-dimensional (2D) phase-contrast magnetic resonance (MR) imaging measurements of total liver blood flow (TLBF) and hepatic arterial fraction in an animal model and evaluate consistency and reproducibility in humans. Materials and Methods Approval from the institutional ethical committee for animal care and research ethics was obtained. Fifteen Sprague-Dawley rats underwent 2D phase-contrast MR imaging of the portal vein (PV) and infrahepatic and suprahepatic inferior vena cava (IVC). TLBF and hepatic arterial flow were estimated by subtracting infrahepatic from suprahepatic IVC flow and PV flow from estimated TLBF, respectively. Direct PV transit-time ultrasonography (US) and fluorescent microsphere measurements of hepatic arterial fraction were the standards of reference. Thereafter, consistency of caval subtraction phase-contrast MR imaging-derived TLBF and hepatic arterial flow was assessed in 13 volunteers (mean age, 28.3 years ± 1.4) against directly measured phase-contrast MR imaging PV and proper hepatic arterial inflow; reproducibility was measured after 7 days. Bland-Altman analysis of agreement and coefficient of variation comparisons were undertaken. Results There was good agreement between PV flow measured with phase-contrast MR imaging and that measured with transit-time US (mean difference, -3.5 mL/min/100 g; 95% limits of agreement [LOA], ±61.3 mL/min/100 g). Hepatic arterial fraction obtained with caval subtraction agreed well with those with fluorescent microspheres (mean difference, 4.2%; 95% LOA, ±20.5%). Good consistency was demonstrated between TLBF in humans measured with caval subtraction and direct inflow phase-contrast MR imaging (mean difference, -1.3 mL/min/100 g; 95% LOA, ±23.1 mL/min/100 g). TLBF reproducibility at 7 days was similar between the two methods (95% LOA, ±31.6 mL/min/100 g vs ±29.6 mL/min/100 g). Conclusion Caval subtraction phase-contrast MR imaging is a simple and clinically viable method for measuring TLBF and hepatic arterial flow. Online supplemental material is available for this article.

  8. Performance evaluation of MPEG internet video coding

    NASA Astrophysics Data System (ADS)

    Luo, Jiajia; Wang, Ronggang; Fan, Kui; Wang, Zhenyu; Li, Ge; Wang, Wenmin

    2016-09-01

    Internet Video Coding (IVC) has been developed in MPEG by combining well-known existing technology elements and new coding tools with royalty-free declarations. In June 2015, IVC project was approved as ISO/IEC 14496-33 (MPEG- 4 Internet Video Coding). It is believed that this standard can be highly beneficial for video services in the Internet domain. This paper evaluates the objective and subjective performances of IVC by comparing it against Web Video Coding (WVC), Video Coding for Browsers (VCB) and AVC High Profile. Experimental results show that IVC's compression performance is approximately equal to that of the AVC High Profile for typical operational settings, both for streaming and low-delay applications, and is better than WVC and VCB.

  9. Cisplatin With or Without WEE1 Inhibitor MK-1775 in Treating Patients With Recurrent or Metastatic Head and Neck Cancer

    ClinicalTrials.gov

    2017-03-22

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Verrucous Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVA Oral Cavity Verrucous Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Verrucous Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVB Oral Cavity Verrucous Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Verrucous Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Stage IVC Oral Cavity Verrucous Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma; Tongue Carcinoma

  10. Prevalence of human papillomavirus types in invasive vulvar cancers and vulvar intraepithelial neoplasia 3 in the United States before vaccine introduction.

    PubMed

    Gargano, Julia W; Wilkinson, Edward J; Unger, Elizabeth R; Steinau, Martin; Watson, Meg; Huang, Youjie; Copeland, Glenn; Cozen, Wendy; Goodman, Marc T; Hopenhayn, Claudia; Lynch, Charles F; Hernandez, Brenda Y; Peters, Edward S; Saber, Maria Sibug; Lyu, Christopher W; Sands, Lauren A; Saraiya, Mona

    2012-10-01

    The study aimed to determine the baseline prevalence of human papillomavirus (HPV) types in invasive vulvar cancer (IVC) and vulvar intraepithelial neoplasia 3 (VIN 3) cases using data from 7 US cancer registries. Registries identified eligible cases diagnosed in 1994 to 2005 and requested pathology laboratories to prepare 1 representative block for HPV testing on those selected. Hematoxylin-eosin-stained sections preceding and following those used for extraction were reviewed to confirm representation. Human papillomavirus was detected using L1 consensus polymerase chain reaction (PCR) with PGMY9/11 primers and type-specific hybridization, with retesting of samples with negative and inadequate results with SPF10 primers. For IVC, the confirmatory hematoxylin-eosin slides were re-evaluated to determine histological type. Descriptive analyses were performed to examine distributions of HPV by histology and other factors. Human papillomavirus was detected in 121/176 (68.8%) cases of IVC and 66/68 (97.1%) cases of VIN 3 (p < .0001). Patients with IVC and VIN 3 differed by median age (70 vs 55 y, p = .003). Human papillomavirus 16 was present in 48.6% of IVC cases and 80.9% of VIN 3 cases; other high-risk HPV was present in 19.2% of IVC cases and 13.2% of VIN 3 cases. Prevalence of HPV differed by squamous cell carcinoma histological subtype (p < .0001) as follows: keratinizing, 49.1% (n = 55); nonkeratinizing, 85.7% (n = 14), basaloid, 92.3% (n = 14), warty 78.2% (n = 55), and mixed warty/basaloid, 100% (n = 7). Nearly all cases of VIN 3 and two thirds of IVC cases were positive for high-risk HPV. Prevalence of HPV ranged from 49.1% to 100% across squamous cell carcinoma histological subtypes. Given the high prevalence of HPV in IVC and VIN 3 cases, prophylactic vaccines have the potential to decrease the incidence of vulvar neoplasia.

  11. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr; Thony, Frederic, E-mail: FThony@chu-grenoble.fr; Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable ratemore » of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.« less

  12. Inferior Vena Cava Filter from Left-Sided Superior Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nair, Sujit, E-mail: drsnnair@hotmail.com; Ettles, Duncan; Robinson, Graham

    We describe the unusual case of a 71-year-old male with a history of deep vein thrombosis and recurrent multiple pulmonary embolism (PE) despite adequate anticoagulation. Computed tomography (CT) and brachiocephalic venography revealed a left-sided superior vena cava. We describe successful placement of an inferior vena cava filter via a left-sided superior vena cava.

  13. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  14. Phase II Randomized Trial of the Combination of Cetuximab and Sorafenib or Single Agent Cetuximab

    ClinicalTrials.gov

    2017-12-28

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  15. Sorafenib Tosylate, Cisplatin, and Docetaxel in Treating Patients With Recurrent or Metastatic Squamous Cell Carcinoma of the Head and Neck

    ClinicalTrials.gov

    2018-05-22

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Oral Cavity Squamous Cell Carcinoma; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  16. PI3K Inhibitor BKM120 and Cetuximab in Treating Patients With Recurrent or Metastatic Head and Neck Cancer

    ClinicalTrials.gov

    2017-05-22

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  17. Preface

    NASA Astrophysics Data System (ADS)

    Kövér, László

    2014-10-01

    This Special Issue of the journal Applied Surface Science contains full papers from a selection of contributions presented in the Applied Surface Science sessions of the 19th International Vacuum Congress (IVC-19) held in the Palais des Congrès, Paris, between September 9 and 13, 2013. The triennial IVC conferences represent major meetings in the field of the vacuum related sciences and are the largest scientific events of the International Union for Vacuum Science, Technique and Applications (IUVSTA). The IVC-19 and partner conferences had altogether 2555 participants. Supported by the Applied Surface Science Division of IUVSTA, the Applied Surface Science part was one of the most attended among the sub-conferences of the IVC-19. This Special Issue - without trying to achieve completeness - intends to provide a cross section of the topics of the Applied Surface Science and joint sessions of the IVC-19, covering important fields such as Surface Analysis, Surface Modifications, Surface Chemistry and Catalysis, Quantitative Surface and Interface Analysis, Coatings, Tribology, Adhesion, Characterization of Nanomaterials, Energy and Sustainable Development, Self Assembly, Nano-instrumentation, SPM and Novel Probe Techniques, New Approaches and Novel Applications of Surface/Interface Analytical Methods.

  18. Effects of processing parameters on immersion vacuum cooling time and physico-chemical properties of pork hams.

    PubMed

    Feng, Chao-Hui; Drummond, Liana; Zhang, Zhi-Hang; Sun, Da-Wen

    2013-10-01

    The effects of agitation (1002 rpm), different pressure reduction rates (60 and 100 mbar/min), as well as employing cold water with different initial temperatures (IWT: 7 and 20°C) on immersion vacuum cooling (IVC) of cooked pork hams were experimentally investigated. Final pork ham core temperature, cooling time, cooling loss, texture properties, colour and chemical composition were evaluated. The application for the first time of agitation during IVC substantially reduced the cooling time (47.39%) to 4.6°C, compared to IVC without agitation. For the different pressure drop rates, there was a trend that shorter IVC cooling times were achieved with lower cooling rate, although results were not statistically significant (P>0.05). For both IWTs tested, the same trend was observed: shorter cooling time and lower cooling loss were obtained under lower linear pressure drop rate of 60 mbar/min (not statistically significant, P>0.05). Compared to the reference cooling method (air blast cooling), IVC achieved higher cooling rates and better meat quality. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. The use of retrievable inferior vena cava filters in pregnancy: Another successful case report, but are we actually making a difference?

    PubMed

    Du Plessis, Lodewyk E; Mol, Ben W; Svigos, John M

    2016-09-01

    Pregnant women with venous thromboembolism are traditionally managed with anticoagulation, but inferior vena cava filters are an alternative. We balanced risks and benefits of an inferior vena cava filter in a decision analysis. We constructed a decision model to compare in pregnant women with VTE the outcome of (1) inferior vena cava filter and anticoagulant treatment versus (2) anticoagulant treatment only. Assuming a 63% risk reduction from an inferior vena cava filter (baseline mortality rate of venous thromboembolism of 0.5%), 318 women would need to be treated with inferior vena cava filters to prevent one venous thromboembolism related maternal death. Sensitivity analyses indicated that at a mortality rate of 0.5% the risk reduction from inferior vena cava filters needed to be 80%, while at a mortality rate of 2% a risk reduction of 20% would justify inferior vena cava filters. In view of their potential morbidity, inferior vena cava filters should be restricted to pregnant woman at strongly increased risk of recurrent venous thromboembolism.

  20. Combat Surgery: Medical Decision Trees for Treatment of Naval Combat Casualties

    DTIC Science & Technology

    1991-02-01

    inferior vena cava ? NO Is there a hole or tear of left atrium and/or pulmonary veins? NO l ** HEART INJURY ASSESSMENT MODULE T027 2...from holes in either superior or inferior vena cava ? YES NO See Pericardial Vena Cava Injury Module See Bleeding Into Pericardium Module T018...MODULE T018 1/1 Is blood coming from area of superior vena cava ? YES NO See Superior Vena Cava Wound

  1. Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.

    PubMed

    Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G

    2013-04-01

    This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.

  2. Veno-venous extracorporeal membrane oxygenation using a double-lumen bi-caval cannula for severe respiratory failure post total artificial heart implantation.

    PubMed

    Miessau, J; Yang, Q; Unai, S; Entwistle, J W C; Cavarocchi, N C; Hirose, H

    2015-07-01

    We report a unique utilization of a double-lumen, bi-caval Avalon cannula for veno-venous (VV) extracorporeal membrane oxygenation (ECMO) during placement of a total artificial heart (TAH, SynCardia, Tucson, AZ). A 22-year-old female with post-partum cardiomyopathy was rescued on veno-arterial (VA) ECMO because of cardiogenic shock. The inability to wean ECMO necessitated implantation of the TAH as a bridge to transplant. In addition, the patient continued to have respiratory failure and concomitant VV ECMO was planned with the implant. During TAH implantation, the Avalon cannula was placed percutaneously from the right internal jugular vein into the inferior vena cava (IVC) under direct vision while the right atrium was open. During VV ECMO support, adequate flows on both ECMO and TAH were maintained without adverse events. VV ECMO was discontinued, without reopening the chest, once the patient's respiratory failure improved. However, the patient subsequently developed a profound respiratory acidosis and required VV ECMO for CO2 removal. The Avalon cannula was placed in the femoral vein to avoid accessing the internal jugular vein and risking damage to the TAH. The patient's oxygenation eventually improved and the cannula was removed at the bedside. The patient was supported for 22 days on VV ECMO and successfully weaned from the ventilator prior to her orthotropic heart transplantation. © The Author(s) 2014.

  3. Ultrasound of Jugular Veins for Assessment of Acute Dyspnea in Emergency Departments and for the Assessment of Acute Heart Failure.

    PubMed

    Tzadok, Batsheva; Shapira, Shay; Tal-Or, Eran

    2018-05-01

    When a patient arrives at the emergency department (ED) presenting with symptoms of acute decompensated heart failure (ADHF), it is possible to reach a definitive diagnosis through many different venues, including medical history, physical examination, echocardiography, chest X-ray, and B-type natriuretic peptide (BNP) levels. Point-of-care ultrasound (POCUS) has become a mainstream tool for diagnosis and treatment in the field of emergency medicine, as well as in various other departments in the hospital setting. Currently, the main methods of diagnosis of ADHF using POCUS are pleural B-lines and inferior vena cava (IVC) width and respiratory variation. To examine the potential use and benefits of bedside ultrasound of the jugular veins in the evaluation of dyspneic patients for identification of ADHF. A blood BNP level was drawn from each participant at time of recruitment. The area and size of the internal jugular vein (IJV) during inspiration and expiration were examined. Our results showed that the respiratory area change of the IJVs had a specificity and sensitivity of nearly 70% accuracy rate in indentifying ADHF in our ED. Ultrasound of the IJV may be a useful tool for the diagnosis of ADHF because it is easy to measure and requires little skill. It is also not affected by patient body habitus.

  4. Emergency pancreatoduodenectomy for complex injuries of the pancreas and duodenum

    PubMed Central

    Krige, Jake E; Nicol, Andrew J; Navsaria, Pradeep H

    2014-01-01

    Background This single-centre study evaluated the outcome of a pancreatoduodenectomy for Grade 5 injuries of the pancreas and duodenum. Methods Prospectively recorded data of patients who underwent a pancreatoduodenectomy for trauma at a Level I Trauma Centre during a 22-year period were analysed. Results Nineteen (17 men and 2 women, median age 28 years, range 14–53 years) out of 426 patients with pancreatic injuries underwent a pancreatoduodenectomy (gunshot n = 12, blunt trauma n = 6 and stab wound n = 1). Nine patients had associated inferior vena cava (IVC) or portal vein (PV) injuries. Five patients had initial damage control procedures and underwent a definitive operation at a median of 15 h (range 11–92) later. Twelve had a pylorus-preserving pancreatoduodenectomy (PPPD) and 7 a standard Whipple. Three patients with APACHE II scores of 15, 18, 18 died post-operatively of multi-organ failure. All 16 survivors had Dindo-Clavien grade I (n = 1), grade II (n = 7), grade IIIa (n = 2), grade IVa (n = 6) post-operative complications. Factors complicating surgery were shock on admission, number of associated injuries, coagulopathy, hypothermia, gross bowel oedema and traumatic pancreatitis. Conclusions A pancreatoduodenectomy is a life-saving procedure in a small cohort of stable patients with non-reconstructable pancreatic head injuries. Damage control before a pancreatoduodenectomy will salvage a proportion of the most severely injured patients who have multiple injuries. PMID:24841125

  5. Emergency pancreatoduodenectomy for complex injuries of the pancreas and duodenum.

    PubMed

    Krige, Jake E; Nicol, Andrew J; Navsaria, Pradeep H

    2014-11-01

    This single-centre study evaluated the outcome of a pancreatoduodenectomy for Grade 5 injuries of the pancreas and duodenum. Prospectively recorded data of patients who underwent a pancreatoduodenectomy for trauma at a Level I Trauma Centre during a 22-year period were analysed. Nineteen (17 men and 2 women, median age 28 years, range 14-53 years) out of 426 patients with pancreatic injuries underwent a pancreatoduodenectomy (gunshot n = 12, blunt trauma n = 6 and stab wound n = 1). Nine patients had associated inferior vena cava (IVC) or portal vein (PV) injuries. Five patients had initial damage control procedures and underwent a definitive operation at a median of 15 h (range 11-92) later. Twelve had a pylorus-preserving pancreatoduodenectomy (PPPD) and 7 a standard Whipple. Three patients with APACHE II scores of 15, 18, 18 died post-operatively of multi-organ failure. All 16 survivors had Dindo-Clavien grade I (n = 1), grade II (n = 7), grade IIIa (n = 2), grade IVa (n = 6) post-operative complications. Factors complicating surgery were shock on admission, number of associated injuries, coagulopathy, hypothermia, gross bowel oedema and traumatic pancreatitis. A pancreatoduodenectomy is a life-saving procedure in a small cohort of stable patients with non-reconstructable pancreatic head injuries. Damage control before a pancreatoduodenectomy will salvage a proportion of the most severely injured patients who have multiple injuries. © 2014 International Hepato-Pancreato-Biliary Association.

  6. The effect of partial portal decompression on portal blood flow and effective hepatic blood flow in man: a prospective study.

    PubMed

    Rosemurgy, A S; McAllister, E W; Godellas, C V; Goode, S E; Albrink, M H; Fabri, P J

    1995-12-01

    With the advent of transjugular intrahepatic porta-systemic stent shunt and the wider application of the surgically placed small diameter prosthetic H-graft portacaval shunt (HGPCS), partial portal decompression in the treatment of portal hypertension has received increased attention. The clinical results supporting the use of partial portal decompression are its low incidence of variceal rehemorrhage due to decreased portal pressures and its low rate of hepatic failure, possibly due to maintenance of blood flow to the liver. Surprisingly, nothing is known about changes in portal hemodynamics and effective hepatic blood flow following partial portal decompression. To prospectively evaluate changes in portal hemodynamics and effective hepatic blood flow brought about by partial portal decompression, the following were determined in seven patients undergoing HGPCS: intraoperative pre- and postshunt portal vein pressures and portal vein-inferior vena cava pressure gradients, intraoperative pre- and postshunt portal vein flow, and pre- and postoperative effective hepatic blood flow. With HGPCS, portal vein pressures and portal vein-inferior vena cava pressure gradients decreased significantly, although portal pressures remained above normal. In contrast to the significant decreases in portal pressures, portal vein blood flow and effective hepatic blood flow do not decrease significantly. Changes in portal vein pressures and portal vein-inferior vena cava pressure gradients are great when compared to changes in portal vein flow and effective hepatic blood flow. Reduction of portal hypertension with concomitant maintenance of hepatic blood flow may explain why hepatic dysfunction is avoided following partial portal decompression.

  7. Heart Transplant in Patient With Isolated Left Superior Vena Cava by Atrial Appendage Rotation.

    PubMed

    Reyes, Karl M; Gupta, Dipankar; Fricker, Frederick Jay; Cooke, Susan; Bleiweis, Mark S

    2018-06-01

    Orthotopic heart transplantation in patients with an isolated persistent left superior vena cava is extremely rare, and the anastomotic connection between a right-sided donor superior vena cava and left-sided recipient superior vena cava can be challenging to perform. We present a novel technique used in an infant female, using the left atrial appendage to extend the superior vena cava anastomosis. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. [Differences in influenza vaccination coverage among subgroups of adult immigrants residing in Italy at risk for complications (2012-2013)].

    PubMed

    Fabiani, Massimo; Di Napoli, Anteo; Riccardo, Flavia; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio

    2017-01-01

    to evaluate differences in influenza vaccination coverage (IVC) in immigrants at risk for influenza-related complications, according to their area of origin and length of stay in Italy. cross-sectional survey conducted on the sample of foreign citizens included in the survey on health conditions and use of health services of the Italian resident population (Italian national institute of statistics, 2012-2013). analysis conducted on 885 foreign adult citizens (≥18 years) at risk for influenza-related complications (elderly residents ≥65 years and residents with specific chronic diseases). vaccination coverage ratios (VCR) comparison between long-term immigrants (≥10 years) and recent immigrants (<10 years), and between non-African and African immigrants, adjusted by demographic and socioeconomic characteristics and level of health services utilization. IVC among immigrants was 15.6%, significantly higher in long-term immigrants (18.3%) compared to recent immigrants (10.2%) (VCR: 1.79; 95%CI 1.21-2.66), and in non-African immigrants (17.1%) compared to African immigrants (9.4%) (VCR: 1.82; 95%CI 1.04-3.17). After adjusting on the basis of demographic and socioeconomic characteristics and for level of health services utilization between the compared subgroups, the difference in IVC according to the length of stay was greatly reduced (VCR: 1.41; 95%CI 0.94- 2.10), while IVC difference reduction according to area of origin was less relevant (VCR: 1.66; 95%CI 0.95-2.91). demographic and socioeconomic characteristics and level of health services utilization explained part of the difference in IVC between the compared subgroups, particularly between long-term and recent immigrants. The difference in IVC between African immigrants and immigrants from other areas remained quite pronounced even after adjusting on the basis of these factors. This suggests that IVC, especially in African immigrants, is affected by other informal barriers, such as cultural and linguistic barriers, that need to be addressed when planning effective immunization access strategies.

  9. High-Dose Intravenous Vitamin C Combined with Cytotoxic Chemotherapy in Patients with Advanced Cancer: A Phase I-II Clinical Trial

    PubMed Central

    Hoffer, L. John; Robitaille, Line; Zakarian, Robert; Melnychuk, David; Kavan, Petr; Agulnik, Jason; Cohen, Victor; Small, David; Miller, Wilson H.

    2015-01-01

    Background Biological and some clinical evidence suggest that high-dose intravenous vitamin C (IVC) could increase the effectiveness of cancer chemotherapy. IVC is widely used by integrative and complementary cancer therapists, but rigorous data are lacking as to its safety and which cancers and chemotherapy regimens would be the most promising to investigate in detail. Methods and Findings We carried out a phase I-II safety, tolerability, pharmacokinetic and efficacy trial of IVC combined with chemotherapy in patients whose treating oncologist judged that standard-of-care or off-label chemotherapy offered less than a 33% likelihood of a meaningful response. We documented adverse events and toxicity associated with IVC infusions, determined pre- and post-chemotherapy vitamin C and oxalic acid pharmacokinetic profiles, and monitored objective clinical responses, mood and quality of life. Fourteen patients were enrolled. IVC was safe and generally well tolerated, although some patients experienced transient adverse events during or after IVC infusions. The pre- and post-chemotherapy pharmacokinetic profiles suggested that tissue uptake of vitamin C increases after chemotherapy, with no increase in urinary oxalic acid excretion. Three patients with different types of cancer experienced unexpected transient stable disease, increased energy and functional improvement. Conclusions Despite IVC’s biological and clinical plausibility, career cancer investigators currently ignore it while integrative cancer therapists use it widely but without reporting the kind of clinical data that is normally gathered in cancer drug development. The present study neither proves nor disproves IVC’s value in cancer therapy, but it provides practical information, and indicates a feasible way to evaluate this plausible but unproven therapy in an academic environment that is currently uninterested in it. If carried out in sufficient numbers, simple studies like this one could identify specific clusters of cancer type, chemotherapy regimen and IVC in which exceptional responses occur frequently enough to justify appropriately focused clinical trials. Trial Registration ClinicalTrials.gov NCT01050621 PMID:25848948

  10. Chemotherapy With or Without Bevacizumab in Treating Patients With Recurrent or Metastatic Head and Neck Squamous Cell Carcinoma

    ClinicalTrials.gov

    2018-06-19

    Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Major Salivary Gland Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary

  11. Effect of Ventilated Caging on Water Intake and Loss in 4 Strains of Laboratory Mice

    PubMed Central

    Nicolaus, Mackenzie L; Bergdall, Valerie K; Davis, Ian C; Hickman-Davis, Judy M

    2016-01-01

    Food availability, temperature, humidity, strain, and caging type all affect water consumption by mice. Measurement of transepidermal water loss (TEWL) is a new technique for the quantification of water turnover in mice. To understand water turnover in common strains of adult mice, male and female SCID, SKH, C57BL/6, and FVB mice were housed in same-sex groups of 5 animals in static cages or IVC. Body weight, TEWL, urine osmolality, and water consumption of mice and intracage temperature and humidity were measured every 48 h for comparison. Static cages were monitored for 7 d and IVC for 14 d before cage change. Female SCID, FVB, and C57 mice drank less water than did their male counterparts. Male and female SCID, SKH, and FVB mice in IVC drank less water and had higher urine osmolality than did those in static cages. In SCID and SKH mice, TEWL paralleled water consumption. C57 mice in static cages drank less water, had lower urine osmolality, and had less TEWL than did those in IVC. Temperature and humidity within the cage was higher than the macroenvironmental levels for all housing conditions, mouse strains, and sexes. Temperatures within IVC ranged from 76.6 to 81.4 °F compared with 69 ± 0.4 °F in the room. Humidity within IVC ranged from 68% to 79% compared with 27.o% ± 2.7% within the room. These data demonstrate that mouse strain and housing conditions significantly influence water balance and indicate that macroenvironmental measurements do not always reflect the intracage environment. PMID:27657706

  12. Endovascular management of inferior vena cava filter thrombotic occlusion.

    PubMed

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  13. Black pepper essential oil to enhance intravenous catheter insertion in patients with poor vein visibility: a controlled study.

    PubMed

    Kristiniak, Susan; Harpel, Jean; Breckenridge, Diane M; Buckle, Jane

    2012-11-01

    To evaluate the effect of topically applied black pepper essential oil on easing intravenous catheter insertion (IVC) in patients with no palpable or visible veins compared to a control group (standard nursing practice). Randomized, controlled study. One hundred twenty hospitalized patients, who were referred to a hospital vascular team because of difficulty in accessing veins for IVC insertion. Topical application of 20% essential oil of black pepper in aloe vera gel or standard nursing care (hot packs with or without vigorous tactile stimulation). Pre- and post-test vein visibility and/or palpability and number of attempts at IVC insertion. A higher percentage of patients achieved optimal scoring (vein score=2) or improved scoring (vein score of 1 or 2) to black pepper intervention than standard nursing care. The black pepper group also reduced the number of patients whose veins were still not visible or palpable after the intervention to nearly half that of the control group (p<0.05). The number of IVC attempts following black pepper was also half that of the control group. Topical application of black pepper is a viable and effective way to enhance vein visibility and palpability prior to intravenous insertion in patients with limited vein accessibility; it also improves ease of IVC insertion.

  14. Prospective surveillance of phlebitis associated with peripheral intravenous catheters.

    PubMed

    Malach, Tal; Jerassy, Ziona; Rudensky, Bernard; Schlesinger, Yechiel; Broide, Etty; Olsha, Oded; Yinnon, Amos M; Raveh, David

    2006-06-01

    Guidelines have been published for prevention of phlebitis associated with peripheral intravenous catheters (IVC), but this complication continues to occur. We sought to determine the rate of phlebitis associated with peripheral IVCs to identify predictors for phlebitis and to isolate pathogenic bacteria from phlebitic catheter tips. Nine-point prevalence studies were conducted during the years 1996-2003 of all hospitalized patients with a peripheral IVC. During the last 3 surveys, conducted in 2003, phlebitic lines were removed, and, for each line, 1 to 2 nonphlebitic lines, in place for 48 to 72 hours, were removed and cultured as controls. In between these surveys, findings and guidelines for improvement were distributed to the staff. During these surveys, 40% +/- 8% of hospitalized patients had a peripheral IVC. The rate of peripheral IVC-associated phlebitis decreased from 12.7% (20/157) in 1998 to 2.6% (5/189) in 2003 (P < .01). Factors significantly associated with phlebitis included pain (P < .001), presence of the catheter for longer than 3 days (P < .05), and cleanliness of the dressing (P < .01). The rate of phlebitis associated with peripheral intravenous catheters decreased significantly throughout the study period. The identification of predictors for phlebitis and the dissemination of this information in an educational drive may have contributed to this improvement.

  15. Interlaminar and lateral excitatory amino acid connections in the striate cortex of monkey.

    PubMed

    Kisvarday, Z F; Cowey, A; Smith, A D; Somogyi, P

    1989-02-01

    The intrinsic excitatory amino acid pathways within the striate cortex of monkeys were studied by autoradiographic detection of retrogradely labeled somata following microinjections of D-3H-aspartate (D-3H-Asp) into different layers. The labeled amino acid was selectively accumulated by subpopulations of neurons and, to a small extent, by glial cells, the latter mainly in the supragranular layers. Immunocytochemical detection of neurons containing GABA showed that, apart from a few cells exclusively in layer I, GABAergic neurons do not accumulate D-3H-Asp. Several lines of evidence suggest that D-3H-Asp uptake occurred only at nerve terminals; thus, the pattern of perikaryal labeling allowed the delineation of interlaminar and lateral projections. Neurons in layer I probably project laterally, and layer I receives wide-ranging projections from layer IVB and layer V from cells up to 1300 microns laterally. Some neurons in layer II send a focused projection to lower layer VI. Some neurons in layers II/III project up to 1 mm laterally within their own layer, but relatively few neurons can be labeled in these projections. Similarly, in layers II/III few neurons can be retrogradely labeled from layers V and upper VI, and this projection is organized such that cells closer to the pia project deeper in layer V/VI. The connections of layer IVA could not be revealed separately because of the difficulty of confining injections to this thin sublamina. Neurons in layer IVB project up to 1300 microns within IVB itself. A small number of cells from IVB also project to layers III, IVC-alpha, V, and VI with much more restricted lateral spread. Neurons in upper IVC-alpha send axons to layer IVB with at least 600-800 microns lateral spread. Neurons in lower IVC-alpha/upper IVC-beta project to layer III with at least 300-500 microns lateral spread. The bottom 50-80 microns of layer IVC-beta contains neurons with a very focused projection, apparently exclusively to the layer III/IVA border region. Both layers IVC alpha and beta have rich connections within themselves, the beta sublayer having more restricted lateral connections. Some neurons in layer IVC-beta give a laterally restricted small input to layers IVC-alpha and IVB. Both IVC-alpha and -beta project to layers V and VI, and these projections are spread at least 400 microns laterally. Neurons in layer V project to all layers, but the projection to layers I-III and within layer V itself spread much further laterally than the projections to layers IV and VI.(ABSTRACT TRUNCATED AT 400 WORDS)

  16. PO-60 - Renal tumors with extensive vascular disease: management challenges in a pediatric series from the Hospital for Sick Children.

    PubMed

    Zamperlini-Netto, G; Zanette, A; Wehbi, E; Williams, S; Grant, R M; Brandao, L R

    2016-04-01

    Venous thrombotic events (VTE) are becoming more and more common in children, particularly in the hospital setting. To date, 1 in 200 children admitted to tertiary pediatric hospitals are now being recognized to develop VTE. Amongst those patients with an identified thrombotic occlusion, pediatric patients diagnosed with renal tumors have long been recognized, but their ideal management in the instances of vascular invasion remains controversial. We describe the clinical behavior of patients diagnosed with renal tumors and extra renal vascular involvement at The Hospital for Sick Children in Toronto, Canada. A retrospective analysis was conducted in patients diagnosed from 1990 to 2012. Data collected included: age, gender, symptoms at presentation, staging, pathology report, radiological evidence of intravascular thrombus [i.e. renal veins (RV), inferior vena cava (IVC) and right atrium (RA)], intraoperative findings, therapeutic protocol implemented and anticoagulation; for outcomes, tumor and/or thrombus recurrence, thromboembolic phenomena [i.e. pulmonary embolism (PE)] and survival. Of 299 patients with renal tumors identified, 292 were included: Wilms (219), Renal Cell Carcinoma (RCC, 29), Clear Cell Sarcoma of the Kidney (CCSK, 12), others (32). The median age of the group was 4.53years (4days - 18 years). Extra renal vascular disease was identified in 29 patients, with a median age 7.05years (0.6-16 years; p=0.03), including Wilms tumors (22/219, 10%), RCC (2/29, 7%), CCSK (1/12, 8.3%) and others (4/32, 12.5%; p=0.01). Vascular involvement comprised exclusive evidence of RV disease (7), IVC disease (19; 15 infra-hepatic), RA disease (3) and PE (5).Treatment escalation because of vascular disease included neo-adjuvant chemotherapy (12; Wilms [11], RCC [1]), intraoperative cavectomy/ thrombectomy (1; Wilms), and cavotomies (11 Wilms [7], RCC [1], CCSK [1], PNET [1], sarcoma [1]). Four patients were placed under cardiopulmonary bypass. Anticoagulation was administered in 9/29 patients for their tumor-related thrombus, and one had a minor bleeding complications (oozing from the central venous line insertion site). Renal tumors with vascular invasion are a rare and challenging entity. Treatment included mostly cancer-related therapies and the role of vascular surgical approaches and/or systemic anticoagulation remains to be clarified. © 2016 Elsevier Ltd. All rights reserved.

  17. Dynamic contrast-enhanced magnetic resonance imaging of abdominal solid organ and major vessel: comparison of enhancement effect between Gd-EOB-DTPA and Gd-DTPA.

    PubMed

    Tamada, Tsutomu; Ito, Katsuyoshi; Sone, Teruki; Yamamoto, Akira; Yoshida, Koji; Kakuba, Koki; Tanimoto, Daigo; Higashi, Hiroki; Yamashita, Takenori

    2009-03-01

    To evaluate the differences in enhancement of the abdominal solid organ and the major vessel on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) obtained with gadolinium ethoxybenzyldiethylenetriamine pentaacetic acid (Gd-EOB-DTPA: EOB) and gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) in the same patients. A total of 13 healthy volunteers underwent repeat assessments of abdominal MR examinations with DCE-MRI using either Gd-DTPA at a dose of 0.1 mmol/kg body weight or EOB at a dose of 0.025 mmol/kg body weight. DCE images were obtained at precontrast injection and in the arterial phase (AP: 25 seconds), portal phase (PP: 70 seconds), and equilibrium phase (EP: 3 minutes). The signal intensities (SIs) of liver at AP, PP, and EP; the SIs of spleen, renal cortex, renal medulla, pancreas, adrenal gland, aorta at AP; and the SIs of portal vein and inferior vena cava (IVC) at PP were defined using region-of-interest measurements, and were used for calculation of signal intensity ratio (SIR). The mean SIRs of liver (0.195+/-0.140), spleen (1.35+/-0.353), renal cortex (1.58+/-0.517), renal medulla (0.548+/-0.259), pancreas (0.540+/-0.183), adrenal gland (1.04+/-0.405), and aorta (2.44+/-0.648) at AP as well as the mean SIRs of portal vein (1.85+/-0.477) and IVC (1.16+/-0.187) at PP in the EOB images were significantly lower than those (0.337+/-0.200, 1.99+/-0.443, 2.01+/-0.474, 0.742+/-0.336, 0.771+/-0.227, 1.26+/-0.442, 3.22+/-1.20, 2.73+/-0.429, and 1.68+/-0.366, respectively) in the Gd-DTPA images (P<0.05 each). There was no significant difference in mean SIR of liver at PP between EOB (0.529+/-0.124) and Gd-DTPA (0.564+/-0.139). Conversely, the mean SIR of liver at EP was significantly higher with EOB (0.576+/-0.167) than with Gd-DTPA (0.396+/-0.093) (P<0.001). Lower arterial vascular and parenchymal enhancement with Gd-EOB, as compared with Gd-DTPA, may require reassessment of its dose, despite the higher late venous phase liver parenchymal enhancement. Copyright (c) 2009 Wiley-Liss, Inc.

  18. Günther Tulip and Celect IVC filters in multiple-trauma patients.

    PubMed

    Rosenthal, David; Kochupura, Paul V; Wellons, Eric D; Burkett, Allison B; Methodius-Rayford, Walaya C

    2009-08-01

    To evaluate results with the retrievable Günther Tulip (GT) and Celect inferior vena cava filters (IVCFs) placed at the intensive care unit (ICU) bedside under "real-time" intravascular ultrasound (IVUS) guidance in multiple-trauma patients. Between December 2004 and December 2008, 187 multiple-trauma patients (109 men; mean age 44+/-2 years, range 17-71) with contraindications to low-dose anticoagulation therapy or sequential compression devices had Günther Tulip (n = 97) or Celect (n = 90) retrievable IVCFs placed under real-time IVUS guidance. Günther Tulip filters were inserted using a "double-puncture" technique. The Celect IVCFs were placed with a simplified single-puncture technique in which the filter introducer sheath was advanced until the radiopaque tip "covered" the IVUS image of the renal vein, indicating that the filter sheath was in position for filter deployment. The 2 filter groups were compared on the endpoints of technical implantation success, retrievability, prevention of PE, and procedure-related deep vein thrombosis (DVT). As verified by abdominal radiography, 93.1% (174/187) of IVCFs were placed without complications; 6 IVCFs (all GT; p = 0.03 versus Celect) were misplaced in the iliac vein but uneventfully retrieved and replaced in the IVC within 24 hours. Two insertion site femoral vein DVTs (both in the dual puncture group; p>0.2) and 5 groin hematomas occurred during follow-up. GT filters were in place a mean of 107 days and Celect 97 days. In this time, 2 pulmonary embolisms occurred (1 in each group; p>0.2). Of the 115 filters scheduled for retrieval (50 Günther Tulip, 65 Celect), 33 (23 Günther Tulip, 10 Celect) could not be retrieved (p = 0.0004). Vena cavography identified filter tilting (>20 degrees ) in 21 cases (15 GT, 6 Celect), while 12 filters (8 GT, 4 Celect) had extended indwell times (mean 187 days) and excessive tissue ingrowth covering the retrieval hook. Subjectively, the Celect filters were clinically "easier" to retrieve; they also had fewer cases of significant tilt (>20%) than the GT filters, but the difference was not statistically significant. GT and Celect IVCFs placed at the ICU bedside under IVUS guidance in multiple-trauma patients was simple, safe, and avoided transporting critically ill patients out of the ICU. Further investigation of the single sheath IVUS technique and the role of retrievable IVCFs in multi-trauma patients is warranted.

  19. Successful transcatheter closure of a large patent ductus venosus with the Amplatzer vascular plug II.

    PubMed

    Cho, Y K; Chang, N-K; Ma, J S

    2009-05-01

    Patent ductus venosus is a rare form of congenital portosystemic shunt from the fetal umbilical vein to the inferior vena cava. The reported surgical treatments include ligation, banding, and liver transplantation. In addition, transcatheter closure with a coil, stent, or original Amplatzer vascular plug (AVP) has been reported. The AVP II, a redesigned version of the original vascular plug with a finer more densely woven nitinol wire and a large diameter (up to 22 mm) is available. This reported case is the first successful occlusion of a large patent ductus venosus with the new AVP II.

  20. Decitabine in Treating Patients With Metastatic Papillary Thyroid Cancer or Follicular Thyroid Cancer Unresponsive to Iodine I 131

    ClinicalTrials.gov

    2014-08-20

    Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer

  1. Guide wire entrapment by inferior vena cava filters: an experimental study.

    PubMed

    Rosen, Michael J; Burns, Justin M; Cobb, William S; Jacobs, David G; Heniford, B Todd; Sing, Ronald F

    2005-09-01

    In situ vena cava filters are at risk for complications with the use of J-tipped guide wires. The purpose of this study was to evaluate the impact of two commonly used J-tipped guide wires on the stability of the four most recently released vena cava filters in an in vitro flow model. Four filters (OptEase [F1], Günther Tulip [F2], Vena Tech LP [F3], and Recovery [F4]) were inserted into an in vitro flow model. Two J-tipped guide wires (0.032-inch [GW-1], 0.035-inch [GW-2]) were passed through each filter (n = 50 passes per wire) for a distance of 10 cm. The inserter was blind as to the effects of the wire. The filters were monitored by an independent observer for adverse events occurring between the filters and the guide wires. These were defined as: migrations (>1 cm), change of position (tilt>10 degrees), and entrapment of the wire (unable to remove wire). Descriptive statistics, chi-square, and Fisher's exact test were used (p < 0.05 considered significant). GW-1 resulted in a lower incidence of entrapment, migration, and tilt for all filters compared with GW-2 (F1, p = 0.003; F2, p < 0.0001; F3, p < 0.0001; F4, p = 0.0004). GW-1 resulted in entrapment in 0%, migration in 7.5%, and tilt in 10.5% of insertions. GW-2 resulted in entrapment in 1%, migration in 26.5%, and tilt in 5.5% of insertions. The incidence of adverse events for GW-1 was significantly different compared with all filters (F1, 0%; F2, 46%; F3, 4%; and F4, 22%; p < 0.0001). Similarly, the incidence of adverse events for GW-2 was significantly different when evaluating all filters (F1, 12%; F2, 48%; F3, 22%; F4 60%; p < 0.0001). The smaller-diameter guide wire resulted in a decreased incidence of adverse events for all filters, but there is still risk for complications. Knowledge of potential complications associated with vena cava filters and the postinsertion use of guide wires are essential to avoid potential mishaps.

  2. Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: a safe alternative to surgical repair.

    PubMed

    Chen, Qiang; Chen, Liang-Wan; Cao, Hua; Zhang, Gui-Can; Chen, Dao-Zhong; Zhang, Hui

    2011-03-01

    Our objective was to evaluate the safety and feasibility of intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency. From January 2005 to December 2008, we enrolled 65 patients who had a secundum atrial septal defect with inferior vena cava rim deficiency closure in our institution. Patients were divided into 2 groups: 35 patients in group I underwent intraoperative device closure with a right lateral minithoracotomy and 30 in group II underwent open cardiac repair with a right lateral thoracotomy and cardiopulmonary bypass. Intraoperative device closure involved a minimal intercostal incision that was performed after full evaluation of the atrial septal defect by transthoracic echocardiography and the insertion of the device through the delivery sheath to occlude the atrial septal defect. The procedure was successful in all patients. In group I, the diameter of the atrial septal defect ranged from 30 to 44 mm (mean, 35.3 ± 3.9 mm), and the size of the implanted occluder ranged from 34 to 48 mm (mean, 40 ± 2.1 mm). The total occlusion rate was 82.9% immediately after the operation, 97.1% at 3 months, and 100% at 12 and 24 months of follow-up. In group II, all patients had successful closure. A follow-up period of 12 to 24 months was obtained in both groups. During the follow-up, there was no recurrence, thrombosis, or device failure. In our comparative studies, group II had significantly longer operative time, intensive care unit stay, and hospital stay than group I (P < .001). The cost of group I was less than that of group II (20,450.9 ± 840.8 RMB vs 25,884.9 ± 701.8; P < .001). Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency is a safe and feasible technique. It has the advantages of cost savings, cosmetic results, and less trauma than surgical closure. Early and midterm results are encouraging. Crown Copyright © 2011. Published by Mosby, Inc. All rights reserved.

  3. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    PubMed

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Complications of inferior vena cava filters.

    PubMed

    Sella, David M; Oldenburg, W Andrew

    2013-03-01

    With the introduction of retrievable inferior vena cava filters, the number being placed for protection from pulmonary embolism is steadily increasing. Despite this increased usage, the true incidence of complications associated with inferior vena cava filters is unknown. This article reviews the known complications associated with these filters and suggests recommendations and techniques for inferior vena cava filter removal. Copyright © 2013. Published by Elsevier Inc.

  5. First-line intra-arterial versus intravenous chemotherapy in unilateral sporadic group D retinoblastoma: evidence of better visual outcomes, ocular survival and shorter time to success with intra-arterial delivery from retrospective review of 20 years of treatment.

    PubMed

    Munier, Francis L; Mosimann, Pascal; Puccinelli, Francesco; Gaillard, Marie-Claire; Stathopoulos, Christina; Houghton, Susan; Bergin, Ciara; Beck-Popovic, Maja

    2017-08-01

    The introduction of intra-arterial chemotherapy (IAC) as salvage treatment has improved the prognosis for eye conservation in group D retinoblastoma. The aim of this study was to compare the outcomes of consecutive patients with advanced unilateral disease treated with either first-line intravenous chemotherapy (IVC) or first-line IAC. This is a retrospective mono-centric comparative review of consecutive patients. Sporadic unilateral retinoblastoma group D cases treated conservatively at Jules-Gonin Eye Hospital and CHUV between 1997 and 2014. From January 1997 to August 2008, IVC, combined with focal treatments, was the primary treatment approach. From September 2008 to October 2014, IAC replaced IVC as first-line therapy. 48 patients met the inclusion criteria, receiving only either IAC or IVC as primary treatment modality. Outcomes of 23 patients treated by IVC were compared with those of 25 treated by IAC; mean follow-up was 105.3 months (range 29.2-218.6) and 41.7 months (range 19.6-89.5), respectively. Treatment duration was significantly shorter in the IAC group (p<0.001). Ten eyes in the IVC group underwent enucleation. Recordable visual acuity of the salvaged eyes was significantly better in the IAC group (0.9 vs 1.4 logarithm of the minimum angle of resolution, p<0.01). No extraocular disease, metastases or long-term systemic complications were observed in either group. The difference in the time frame between treatment groups had an impact on the availability of intravitreal chemotherapy treatment. Despite this, the results reported here imply that eyes treated with first-line IAC will have shorter treatment period, better ocular survival and visual acuity than first-line IVC. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Differences in Influenza Vaccination Coverage between Adult Immigrants and Italian Citizens at Risk for Influenza-Related Complications: A Cross-Sectional Study

    PubMed Central

    Fabiani, Massimo; Riccardo, Flavia; Di Napoli, Anteo; Gargiulo, Lidia; Declich, Silvia; Petrelli, Alessio

    2016-01-01

    Background Due to their increased vulnerability, immigrants are considered a priority group for communicable disease prevention and control in Europe. This study aims to compare influenza vaccination coverage (IVC) between regular immigrants and Italian citizens at risk for its complications and evaluate factors affecting differences. Methods Based on data collected by the National Institute of Statistics during a population-based cross-sectional survey conducted in Italy in 2012–2013, we analysed information on 42,048 adult residents (≥ 18 years) at risk for influenza-related complications and with free access to vaccination (elderly residents ≥ 65 years and residents with specific chronic diseases). We compared IVC between 885 regular immigrants and 41,163 Italian citizens using log-binomial models and stratifying immigrants by area of origin and length of stay in Italy (recent: < 10 years; long-term: ≥ 10 years). Results IVC among all immigrants was 16.9% compared to 40.2% among Italian citizens (vaccination coverage ratio (VCR) = 0.42, 95% confidence interval (CI): 0.36–0.49). Adjusting for sex, age and area of residence, this difference was greatly reduced but remained statistically significant (VCR = 0.71, 95 CI: 0.61–0.81). Further adjustment for socio-economic factors (education, occupation, family composition and economic status) and a composite indicator of health-services utilization did not affect the difference (VCR = 0.78, 95% CI: 0.68–0.90). However, after adjustments, only long-term immigrants from Africa (VCR = 0.49, 95% CI: 0.28–0.85) and recent immigrants (VCR = 0.58, 95% CI: 0.43–0.78) showed a significantly different IVC compared to Italian citizens. Conclusions Differences in demographic characteristics, socio-economic conditions and health-services utilization explained the reduced IVC in most long-term immigrants compared to Italian citizens. By contrast, these differences did not explain the reduced IVC in long-term immigrants from Africa and recent immigrants. This suggests that IVC in these sub-groups is affected by other informal barriers (e.g., cultural and linguistic) that need to be investigated to promote effective immunization access strategies. PMID:27832186

  7. Sunitinib in Treating Patients With Thyroid Cancer That Did Not Respond to Iodine I 131 and Cannot Be Removed by Surgery

    ClinicalTrials.gov

    2017-08-18

    Recurrent Thyroid Gland Carcinoma; Stage III Thyroid Gland Follicular Carcinoma; Stage III Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Medullary Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Medullary Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Medullary Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Medullary Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma

  8. Congenital anomalies of the inferior vena cava revealed on CT in patients with deep vein thrombosis.

    PubMed

    Gayer, G; Luboshitz, J; Hertz, M; Zissin, R; Thaler, M; Lubetsky, A; Bass, A; Korat, A; Apter, S

    2003-03-01

    We describe a possible relationship between inferior vena cava anomalies and extensive thrombosis of the inferior vena cava and the iliac and femoral veins. An anomaly of the inferior vena cava should be considered in young patients who present with deep vein thrombosis of the femoral and iliac veins. Coagulation abnormalities, frequently found in these patients, may be a contributory factor.

  9. Reconstruction of a total avulsion of the hepatic veins and the suprahepatic inferior vena cava secondary to blunt thoracoabdominal trauma.

    PubMed

    Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten

    2011-02-01

    Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.

  10. The fenestrated Kawashima operation for single ventricle with interrupted inferior vena cava.

    PubMed

    Hannan, Robert L; Rossi, Anthony F; Nykanen, David G; Lopez, Leo; Alonso, Francisco; White, Jeffrey A; Burke, Redmond P

    2003-01-01

    An 8-month-old boy with double outlet right ventricle with hypoplastic left ventricle, heterotaxy, left atrial isomerism, bilateral superior vena cavae without bridging vein, and interruption of the inferior vena cava with azygous continuation to the left superior cava underwent a bilateral bidirectional cavopulmonary anastomosis. A calibrated 3-mm connection between the right pulmonary artery and the common atrium was constructed with the proximal right superior vena cava to allow right to left shunting, analogous to a fenestration in a Fontan operation. We hypothesize that in small young patients undergoing the Kawashima operation a fenestration may improve postoperative hemodynamics.

  11. Erlotinib, Docetaxel, and Radiation Therapy in Treating Patients With Locally Advanced Head and Neck Cancer

    ClinicalTrials.gov

    2014-06-05

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer; Untreated Metastatic Squamous Neck Cancer With Occult Primary

  12. Surgical approach to left ventricular inflow obstruction due to dilated coronary sinus.

    PubMed

    Vargas, Florentino J; Rozenbaum, Jorge; Lopez, Ricardo; Granja, Miguel; De Dios, Ana; Zarlenga, Beatriz; Flores, Enrique; Fischman, Enrique; Kreutzer, Eduardo

    2006-07-01

    Left superior vena cava draining to a dilated coronary sinus can cause left ventricular inflow obstruction. Our purpose is to report 4 severely ill patients with this malformation who were operated upon and in whom repair was accomplished using an original surgical approach. An operative procedure was designed, which included complete resection of the wall of the coronary sinus along its entire extension in the left atrium; division of the left superior vena cava; and establishment of the left superior vena cava-right atrial continuity by a wide left superior vena cava-right atrial appendage anastomosis. The series included 1 patient with interrupted inferior vena cava-hemiazygous continuation to left superior vena cava. There were no deaths. Absence of residual left ventricular inflow obstruction was demonstrated at follow-up in all cases, together with an unobstructed left superior vena cava-right atrial appendage-right atrial connection. A predictable relief of the left ventricular inflow obstruction, together with preservation of an adequate drainage for the systemic venous return, were both achieved with this repair.

  13. Pressure-Guided Positioning of Bicaval Dual-Lumen Catheters for Venovenous Extracorporeal Gas Exchange

    DTIC Science & Technology

    2013-01-01

    inferior venae cavae , pumped through a respiratory mem- brane, and returned into the right atrium . The insertion of these cathe- ters is...sheath and advanced through the superior vena cava and the right atrium into the inferior vena cava . Correct position was confirmed via fluoroscopy...these catheters, blood is drained from the superior and inferior venae cavae through two dedicated ports and is pumped through a respiratory

  14. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    PubMed

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P < 0.0001). Breeds with increased risk for duplicated caudal vena cava were Yorkshire Terrier (odds ratio [OR] = 6.41), Poodle (OR = 7.46), West Highland White Terrier (OR = 6.33), and Maltese (OR = 3.87). Presence of a duplicated caudal vena cava was significantly associated with presence of extrahepatic portosystemic shunt(s) (P < 0.004). While uncommon in dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  15. Urologic Oncologic SurveyRobotic level III inferior vena cava tumor thrombectomy: Initial series. Gill IS, Metcalfe C, Abreu A, Duddalwar V, Chopra S, Cunningham M, Thangathurai D, Ukimura O, Satkunasivam R, Hung A, Papalia R, Aron M, Desai M, Gallucci M. J Urol. 2015 Oct;194(4):929-938. [Epub 2015 Apr 6]. doi: 10.1016/j.juro.2015.03.119.

    PubMed

    Meng, Max

    2017-05-01

    Level III inferior vena cava tumor thrombectomy for renal cancer is one of the most challenging open urologic surgeries. We present the initial series of completely intracorporeal robotic level III inferior vena cava tumor thrombectomy. Nine patients underwent robotic level III inferior vena cava thrombectomy and 7 patients underwent level II thrombectomy. The entire operation (high intrahepatic inferior vena cava control, caval exclusion, tumor thrombectomy, inferior vena cava repair, radical nephrectomy, and retroperitoneal lymphadenectomy) was performed exclusively robotically. To minimize the chances of intraoperative inferior vena cava thrombus embolization, an "inferior vena cava-first, kidney-last" robotic technique was developed. Data were accrued prospectively. All 16 robotic procedures were successful, without open conversion or mortality. For level III cases (9), median primary kidney (right 6, left 3) cancer size was 8.5cm (range: 5.3-10.8) and inferior vena cava thrombus length was 5.7cm (range: 4-7). Median operative time was 4.9 hours (range: 4.5-6.3), estimated blood loss was 375ml (range: 200-7,000), and hospital stay was 4.5 days. All surgical margins were negative. There were no intraoperative complications and 1 postoperative complication (Clavien 3b). At a median 7 months of follow-up (range: 1-18) all patients are alive. Compared to level II thrombi the level III cohort trended toward greater inferior vena cava thrombus length (3.3 vs 5.7cm), operative time (4.5 vs 4.9h) and blood loss (290 vs 375ml). With appropriate patient selection, surgical planning and robotic experience, completely intracorporeal robotic level III inferior vena cava thrombectomy is feasible and can be performed efficiently. Larger experience, longer follow-up and comparison with open surgery are needed to confirm these initial outcomes. Copyright © 2017. Published by Elsevier Inc.

  16. Pazopanib Hydrochloride in Treating Patients With Advanced Thyroid Cancer

    ClinicalTrials.gov

    2018-05-08

    Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVA Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVB Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Medullary Carcinoma AJCC v7; Stage IVC Thyroid Gland Undifferentiated (Anaplastic) Carcinoma AJCC v7; Thyroglobulin Antibody Negative; Thyroid Gland Undifferentiated (Anaplastic) Carcinoma

  17. The thoracic surface anatomy of adult black South Africans: A reappraisal from CT scans.

    PubMed

    Keough, N; Mirjalili, S A; Suleman, F E; Lockhat, Z I; van Schoor, A

    2016-11-01

    Surface landmarks or planes taught in anatomy curricula derive from standard anatomical textbooks. Although many surface landmarks are valid, clear age, sex, and population differences exist. We reappraise the thoracic surface anatomy of black South Africans. We analyzed 76 (female = 42; male = 34) thoracoabdominal CT-scans. Patients were placed in a supine position with arms abducted. We analyzed the surface anatomy of the sternal angle, tracheal, and pulmonary trunk bifurcation, azygos vein termination, central veins, heart apex, diaphragm, xiphisternal joint, and subcostal plane using standardized definitions. Surface anatomy landmarks were mostly within the normal variation limits described in previous studies. Variation was observed where the esophagus (T9) and inferior vena cava (IVC) (T8/T9/T10) passed through the diaphragm. The bifurcations of the trachea and pulmonary trunk were inferior to the sternal angle. The subcostal plane level was positioned at L1/L2. The origin of inferior mesenteric artery was mostly inferior to the subcostal plane. Sex differences were noted for the plane of the xiphisternal joint (P = 0.0082), with males (36%) intersecting at T10 and females (36%) intersecting at T9. We provide further evidence for population variations in surface anatomy. The clinical relevance of surface anatomical landmarks depends on descriptions of normal variation. Accurate descriptions of population, sex, age, and body type differences are essential. Clin. Anat. 29:1018-1024, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  18. Iodine I 131 and Pazopanib Hydrochloride in Treating Patients With Recurrent and/or Metastatic Thyroid Cancer Previously Treated With Iodine I 131 That Cannot Be Removed By Surgery

    ClinicalTrials.gov

    2015-11-04

    Recurrent Thyroid Cancer; Stage IVA Follicular Thyroid Cancer; Stage IVA Papillary Thyroid Cancer; Stage IVB Follicular Thyroid Cancer; Stage IVB Papillary Thyroid Cancer; Stage IVC Follicular Thyroid Cancer; Stage IVC Papillary Thyroid Cancer

  19. ESEA Title IV-C Innovation Administration Manual for South Carolina.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Office of Federal Programs.

    The intent of Title IV-C of the Elementary and Secondary Education Act (the Education Amendments of 1974) is to establish innovative and exemplary projects that provide creative or imaginative solutions to problems in the areas of supplementary centers and services, health and nutritional demonstrations, and dropout prevention. The purposes of…

  20. Trace Element Data help Understanding the Origin of Lake Bosumtwi Crater Related Glass (Ivory Coast Tektites, Microtektites, Fall-Back Particles, Suevite Glass)

    NASA Astrophysics Data System (ADS)

    Deutsch, A.; Langenhorst, F.; Berndt, J.

    2015-09-01

    We report for the four internally rather homogeneous groups of glass (IVC, IVC-MT, BOT 12 [suevite], FBG) concentrations of major and 42 minor elements (in-situ data with LA-ICP-MS) as well as Sr-Nd, and DEGAS data.

  1. Two cases of left superior vena cava draining directly to a left atrium with a normal coronary sinus.

    PubMed Central

    Wiles, H B

    1991-01-01

    The most common variation in the thoracic systemic venous system is a persistent left superior vena cava draining to a coronary sinus. A rare anomaly is a persistent left superior vena cava connecting directly to the left atrium. In this situation it is believed that the coronary sinus must be absent. This report describes two cases of a persistent left superior vena cava draining to a left atrium with a normal coronary sinus. Images PMID:2015125

  2. Ecklonia cava promotes hair growth.

    PubMed

    Bak, S S; Ahn, B N; Kim, J A; Shin, S H; Kim, J C; Kim, M K; Sung, Y K; Kim, S K

    2013-12-01

    Previous studies have reported the protective effects on skin elasticity of the edible marine seaweed Ecklonia cava, which acts through regulation of both antioxidative and anti-inflammatory responses. We evaluated the effect of E. cava and one of its components, dioxinodehydroeckol, on hair-shaft growth in cultured human hair follicles and on hair growth in mice. The MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was used to check cell viability of human dermal papilla cells (DPCs) and outer root sheath (ORS) cells after treatment with E. cava and its metabolite, dioxinodehydroeckol. Hair-shaft growth was measured using the in vitro hair-follicle organ-culture system, in the presence or absence of E. cava and dioxinodehydroeckol. Anagen induction activity was examined by topical application of E. cava to the dorsal skin of C57BL/6 mice. Insulin-like growth factor (IGF)-1 expression was measured by reverse transcriptase PCR and ELISA. The proliferation activity was found to be highest for the ethyl acetate-soluble fraction of E. cava (EAFE) in DPCs and in ORS cells. Treatment with EAFE resulted in elongation of the hair shaft in cultured human hair follicles, and promoted transition of the hair cycle from the telogen to the anagen phase in the dorsal skin of C57BL/6 mice. In addition, EAFE induced an increase in IGF-1 expression in DPCs. Dioxinodehydroeckol, a component of E. cava, induced elongation of the hair shaft, an increase in proliferation of DPCs and ORS cells, and an increase in expression of IGF-1 in DPCs. These results suggest that E. cava containing dioxinodehydroeckol promotes hair growth through stimulation of DPCs and ORS cells. © 2013 British Association of Dermatologists.

  3. Left Superior Vena Cava Draining Into Left Atrium in Tetralogy of Fallot-Four Cases of a Rare Association.

    PubMed

    Ramman, Tarun Raina; Dutta, Nilanjan; Chowdhuri, Kuntal Roy; Agrawal, Sunny; Girotra, Sumir; Azad, Sushil; Radhakrishnan, Sitaraman; Iyer, Parvathi Unninayar; Iyer, Krishna Subramony

    2018-01-01

    Persistent left superior vena cava is a common congenital anomaly of the thoracic venous system. Left superior vena cava draining into left atrium is a malformation of sinus venosus and caval system. The anomaly may be a cause of unexplained hypoxia even in adults. It may give rise to various diagnostic and technical challenges during cardiac catheterization and open-heart surgery. It is often detected serendipitously during diagnostic workup. Isolated left superior vena cava opening into left atrium is very commonly associated with other congenital heart defects. But tetralogy of Fallot is very rarely associated with persistent left superior vena cava which drains into left atrium. We report four such cases who underwent surgical correction successfully.

  4. Expression of genes responsible for cell morphogenesis involved in differentiation in porcine buccal pouch mucosal cells during long-term primary culture and real-time proliferation in vitro.

    PubMed

    Dyszkiewicz-Konwińska, M; Bryja, A; Jopek, K; Budna, J; Khozmi, R; Jeseta, M; Bukowska, D; Antosik, P; Bruska, M; Nowicki, M; Zabel, M; Kempisty, B

    2017-01-01

    Recently, using experimental animal model, we demonstrated that porcine buccal pouch mucosal cells reflect increased proliferation capability during primary cultivation in vitro. Although the histological structure and morphogenesis in oral cavity is well recognized, the molecular mechanisms which regulate this process still need further investigation. This study was aimed to analyze the molecular marker expression profile involved in morphogenesis and differentiation capacity of porcine buccal pouch mucosal cells during their long-term primary cultivation in vitro. The experiment was performed on buccal pouch mucosal cells isolated from 80 pubertal crossbred Landrace gilts. After collection, the cells were treated enzymatically and transferred into a primary in vitro culture (IVC) system and cultured for 30 days. The cells were collected for RNA isolation after 7, 15 and 30 days of IVC and were checked for their real-time proliferative status using the RTCA system. We found an increased expression of FN1 and SOX9 genes when calculated against ACTB after 7, and 30 days of IVC, (P less than 0.01, P less than 0.001, respectively). The CXCL12 mRNA was down-regulated after 7, 15 and 30 days of IVC, but not statistically significant. Similar expression profile was observed when calculated against HPRT, however, DAB2 was found to be higher expressed at day 15 of IVC, (P less than 0.05). The cell index measured during real-time cell proliferation was substantially increased between 96 h and 147h of IVC and reached the log phase. Since FN1 and SOX9 revealed significant increase of expression after long-term culture in vitro, it is suggested that expression of these differentiation and stemness genes is accompanied by cell proliferation. Moreover, FN1 and SOX9 might be recognized as new markers of buccal pouch mucosal cell proliferation and differentiation in pigs in in vitro primary culture model.

  5. Entolimod in Treating Patients With Stage III-IV Squamous Cell Head and Neck Cancer Receiving Cisplatin and Radiation Therapy

    ClinicalTrials.gov

    2013-12-10

    Mucositis; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  6. Cross-sectional echocardiographic diagnosis of azygos continuation of the inferior vena cava.

    PubMed

    Huhta, J C; Smallhorn, J F; Macartney, F J

    1984-01-01

    Azygos continuation of the inferior vena cava has importance for both the invasive diagnosis of congenital heart disease by catheterization and for surgical treatment. Cross-sectional echocardiography was used to examine 1,000 patients (1 day to 16 years, mean 3.3 years) who also had angiographic or surgical confirmation. Twenty-eight patients (3%) had azygos continuation (left 13, right 14, bilateral 1) and, in 26 patients, the hepatic portion of the inferior vena cava was absent. Azygos continuation was prospectively detected in all and was directly visualized in subcostal scans as a venous structure posterior to the aorta coursing behind the heart and not entering the inferior aspect of either atrium in 26/28 (93%). Azygos connection to the ipsilateral superior vena cava or atrium was correctly predicted in all. The inferior vena cava was visualized in all patients without azygos continuation, except one neonate with omphalocele. We conclude that cross-sectional echocardiography can accurately detect azygos continuation of the inferior vena cava and predict its side and connection.

  7. Talactoferrin in Treating Patients With Relapsed or Refractory Non-Small Cell Lung Cancer or Squamous Cell Head and Neck Cancer

    ClinicalTrials.gov

    2016-07-30

    Metastatic Squamous Neck Cancer With Occult Primary Squamous Cell Carcinoma; Recurrent Metastatic Squamous Neck Cancer With Occult Primary; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Hypopharynx; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Salivary Gland Squamous Cell Carcinoma; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Non-small Cell Lung Cancer; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Squamous Cell Carcinoma of the Paranasal Sinus and Nasal Cavity; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  8. Association between expression of cumulus expansion markers and real-time proliferation of porcine follicular granulosa cells in a primary cell culture model.

    PubMed

    Ciesiółka, S; Budna, J; Bryja, A; Kranc, W; Chachuła, A; Dyszkiewicz-Konwińska, M; Piotrowska, H; Bukowska, D; Antosik, P; Bruska, M; Brüssow, K P; Nowicki, M; Zabel, M; Kempisty, B

    2016-01-01

    Folliculogenesis is a compound process that involves both ovarian follicle growth and oocyte development, which is tightly attached to the follicular wall. During this process, cells that form the follicle structure undergo substantial morphological and molecular modifications that finally lead to differentiation and specialization of ovarian follicular cells. The differentiation of ovarian cells encompasses formation of follicle, which is composed of theca (TCs), mural granulosa (GCs), and cumulus cells (CCs). It was previously hypothesized that GCs and CCs represent undifferentiated and highly specialized follicular cells, respectively, which may have similar primordial cell origins. In this study, we investigated the expression pattern of cumulus expansion markers such as COX2, HAS2, PTX3, and TSG6 in porcine GCs during short-term, in vitro culture. We hypothesized that these genes may display an important function in GCs in relation to cellular real-time proliferation. The expression pattern of COX2, HAS2, PTX3, and TSG6 was evaluated after using RT-qPCR in relation to confocal microscopy observations of protein expression and distribution during real-time proliferation of porcine follicular GCs. The COX2 and HAS2 mRNAs were highly expressed after 120 h of in vitro culture (IVC), whereas PTX3 and TSG6 mRNAs were increased during the first 24-48 h of IVC (P less than 0.001, P less than 0.01). Conversely, all of the encoded proteins were highly expressed after 144-168 h of IVC as compared to other culture periods (P less than 0.001, P less than 0.01). When analyzing the realtime proliferation of GCs in vitro, we observed a logarithmic increase of cell proliferation between 0 h and 120 h of IVC. However, after 120-168 h of IVC, the cells reached the lag phase of proliferation. Since it is well accepted that porcine GCs undergo luteinization shortly after 24-48 h of IVC, the expression pattern of investigated genes indicated that Cox2 and Has2 are independent from the LH surge, but their increased levels may be upregulated by cell proliferation in vitro. Moreover, higher expression of PTX3 and TSG6 during first 24 h and/or 48 h of IVC suggested that their levels are accompanied by porcine GCs luteinization process.

  9. Lenalidomide and Cetuximab in Treating Patients With Advanced Colorectal Cancer or Head and Neck Cancer

    ClinicalTrials.gov

    2018-05-23

    Recurrent Colon Carcinoma; Recurrent Hypopharyngeal Squamous Cell Carcinoma; Recurrent Laryngeal Squamous Cell Carcinoma; Recurrent Laryngeal Verrucous Carcinoma; Recurrent Lip and Oral Cavity Squamous Cell Carcinoma; Recurrent Metastatic Squamous Cell Carcinoma in the Neck With Occult Primary; Recurrent Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma; Recurrent Nasopharyngeal Keratinizing Squamous Cell Carcinoma; Recurrent Oral Cavity Verrucous Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Recurrent Rectal Carcinoma; Recurrent Salivary Gland Carcinoma; Salivary Gland Squamous Cell Carcinoma; Squamous Cell Carcinoma Metastatic in the Neck With Occult Primary; Stage IV Hypopharyngeal Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Colon Cancer AJCC v7; Stage IVA Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Laryngeal Verrucous Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Major Salivary Gland Cancer AJCC v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Oral Cavity Cancer AJCC v6 and v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Rectal Cancer AJCC v7; Stage IVB Colon Cancer AJCC v7; Stage IVB Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Laryngeal Verrucous Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Major Salivary Gland Cancer AJCC v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Oral Cavity Cancer AJCC v6 and v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Rectal Cancer AJCC v7; Stage IVC Laryngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Laryngeal Verrucous Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Major Salivary Gland Cancer AJCC v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Oral Cavity Cancer AJCC v6 and v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Tongue Carcinoma; Untreated Metastatic Squamous Cell Carcinoma to Neck With Occult Primary

  10. Cross-sectional echocardiographic diagnosis of systemic venous return.

    PubMed Central

    Huhta, J C; Smallhorn, J F; Macartney, F J; Anderson, R H; de Leval, M

    1982-01-01

    To determine the sensitivity and specificity of cross-sectional echocardiography in diagnosing anomalous systemic venous return we used the technique in 800 consecutive children with congenital heart disease and whom the diagnosis was ultimately confirmed by angiography. Cross-sectional echocardiography was performed without prior knowledge of the diagnosis in all but 11 patients, who were recalled because of a known abnormality of atrial situs. The sensitivity of cross-sectional echocardiographic detection of various structures was as follows: right superior vena cava 792/792 (100%); left superior vena cava 46/48 (96%); bilateral superior vena cava 38/40 (95%); bridging innominate vein with bilateral superior vena cava 13/18 (72%); connection of superior caval segment to heart (coronary sinus or either atrium) (100%); absence of suprarenal inferior vena cava 23/23 (100%); azygos continuation of the inferior vena cava 31/33 (91%); downstream connection of azygos continuation, once seen, 21/21 (100%); partial anomalous hepatic venous connection (one hepatic vein not connected to the inferior vena cava) 1/1 (100%); total anomalous hepatic venous connection (invariably associated with left isomerism) 23/23 (100%). The specificity of each above diagnoses was 100% except in one infant with exomphalos in whom absence of the suprarenal inferior vena cava was incorrectly diagnosed. Thus cross-sectional echocardiography is an extremely specific and highly sensitive method of recognizing anomalous systemic venous return. It is therefore of great value of planning both cardiac catheterisation and cannulation for open heart surgery. Images PMID:6751361

  11. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  12. 21 CFR 870.3260 - Vena cava clip.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vena cava clip. 870.3260 Section 870.3260 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3260 Vena cava clip. (a) Identification. A vena...

  13. Successful Percutaneous Retrieval of an Inferior Vena Cava Filter Migrating to the Right Ventricle in a Bariatric Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veerapong, Jula; Wahlgren, Carl Magnus, E-mail: carl.wahlgren@karolinska.s; Jolly, Neeraj

    The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.

  14. The Isolated Perfused Rat Liver and its use in the Study of Chemical Kinetics: Quality and Performance Parameters

    DTIC Science & Technology

    1999-04-01

    atrium , the inferior vena cava was closed with a silk ligature and the liver was carefully excised. 2.4 Liver...withdraw needle. 5.5.10 Secure tip of cannula with ligature and connect medium at lowest flow rate (5 mL/min). 5.5.11 Cut inferior vena cava below the...heart. 5.5.14 Cannulate the superior vena cava via an incision in the right atrium , secure with ligature. 5.5.15 Close ligature around inferior vena cava

  15. Innervation of the sinu-atrial node and neighbouring regions in two human embryos.

    PubMed Central

    Orts Llorca, F; Domenech Mateu, J M; Puerta Fonolla, J

    1979-01-01

    In human embryos of 20 to 23 mm (36 to 40 days) it is possible to identify on the right side a nerve that we may call the sinusal, which originates by several roots from the nervus vagus dexter (Figs. 1A, B, D), descending through the right ventrolateral face of the primary trachea and right bronchus (Fig. 2, arrows). Beaded in appearance, it gives a fine anastomotic branch which, passing in front of the arteria pulmonalis dextra, passes to the left side (Figs. 2B, C, D; AN). At this level it gives the large branch for the nodus sinoatrialis which, penetrating through the wall of the superior vena cava, provides a rich innervation for the nodus sinoatrialis which is already in an advanced stage of differentiation (Fig. 3, 2; Cy, D, AN). Afterwards it gives fine branches which, following the atrial fold, are distributed throughout the posterior face of the atrium dextrum (Fig. 3). It increases in diameter and, passing through the angle formed by the right pulmonary veins with the atrium dextrum, reaches the intrapericardial portion of the inferior vena cava in the vicinity of its outlet from the atrium (Fig. 3, arrows). The whole innervation is parasympathetic at the stages studied. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:438095

  16. Selection of ribozymes that catalyse multiple-turnover Diels–Alder cycloadditions by using in vitro compartmentalization

    PubMed Central

    Agresti, Jeremy J.; Kelly, Bernard T.; Jäschke, Andres; Griffiths, Andrew D.

    2005-01-01

    In vitro compartmentalization (IVC) has previously been used to evolve protein enzymes. Here, we demonstrate how IVC can be applied to select RNA enzymes (ribozymes) for a property that has previously been unselectable: true intermolecular catalysis. Libraries containing 1011 ribozyme genes are compartmentalized in the aqueous droplets of a water-in-oil emulsion, such that most droplets contain no more than one gene, and transcribed in situ. By coencapsulating the gene, RNA, and the substrates/products of the catalyzed reaction, ribozymes can be selected for all enzymatic properties: substrate recognition, product formation, rate acceleration, and turnover. Here we exploit the complementarity of IVC with systematic evolution of ligands by exponential enrichment (SELEX), which allows selection of larger libraries (≥1015) and for very small rate accelerations (kcat/kuncat) but only selects for intramolecular single-turnover reactions. We selected ≈1014 random RNAs for Diels–Alderase activity with five rounds of SELEX, then six to nine rounds with IVC. All selected ribozymes catalyzed the Diels–Alder reaction in a truly bimolecular fashion and with multiple turnover. Nearly all ribozymes selected by using eleven rounds of SELEX alone contain a common catalytic motif. Selecting with SELEX then IVC gave ribozymes with significant sequence variations in this catalytic motif and ribozymes with completely novel motifs. Interestingly, the catalytic properties of all of the selected ribozymes were quite similar. The ribozymes are strongly product inhibited, consistent with the Diels–Alder transition state closely resembling the product. More efficient Diels–Alderases may need to catalyze a second reaction that transforms the product and prevents product inhibition. PMID:16260754

  17. Anomalies of the systemic venous return: a review.

    PubMed

    Mazzucco, A; Bortolotti, U; Stellin, G; Gallucci, V

    1990-06-01

    Congenital anomalies of the systemic venous connection to the heart represent a rather wide and heterogeneous group of malformations, whose physiological consequences may vary from nil to the most severe form of systemic arterial desaturation. The malformations may be summarized as follows: (1) Left superior vena cava connected to the coronary sinus, interrupted inferior vena cava and absent right superior vena cava that do not indicate surgical repair 'per se', but require some technical attention during open heart surgery performed for other anomalies; (2) Left superior vena cava connected to the left atrium, due to incorporation of the coronary sinus into the left atrial cavity, resulting in a right-to-left-shunt; (3) Right superior vena cava or inferior vena cava draining into the left atrium, both are extremely rare and require treatment for the ensuing right-to-left shunt; (4) Total anomalous systemic venous connection to the left atrium, usually combined with atrial isomerism and other very complex heart malformations; (5) Cor triatriatum dexter, which has been frequently diagnosed as an anomalous venous connection for its similar hemodynamic consequences. Such anomalies are reviewed with particular respect to their surgical implications.

  18. Arts and Crafts of the Mississippi Hills. ESEA, Title IV-C, 1982-83.

    ERIC Educational Resources Information Center

    Eaton, Barbara; Weatherford, Martha

    An overview is presented of a 1982-83 Elementary and Secondary Education Act (ESEA), Title IV-C project, designed for 50 talented high school art students, to preserve the arts and crafts in the Mississippi hills area and to enrich existing arts and crafts curriculum. Steps are listed for implementing such a program, a simple program budget is…

  19. An Application of the PMI Model at the Project Level Evaluation of ESEA Title IV-C Projects.

    ERIC Educational Resources Information Center

    McBeath, Marcia

    All of the papers presented as part of a symposium concerned the application of the Planning, Monitoring, and Implementation Model (PMI) to the evaluation of the District of Columbia Public Schools' programs supported by the Elementary Secondary Education Act (ESEA) Title IV-C. PMI was developed to provide a model for systematic evaluation of…

  20. Application of Change Agent Study Findings to the Formulation of Title IVC: Local Role.

    ERIC Educational Resources Information Center

    Weinman, Janice

    This paper addresses three issues--current constraints on the local level that contribute to failures to bring about innovation, conditions that have been isolated as significant to the success of the change process, and ways in which Title IV-C of the Elementary and Secondary Education Act could encourage the presence of these favorable…

  1. Acetylcysteine Rinse in Reducing Saliva Thickness and Mucositis in Patients With Head and Neck Cancer Undergoing Radiation Therapy

    ClinicalTrials.gov

    2018-04-17

    Mucositis; Oral Complications; Recurrent Adenoid Cystic Carcinoma of the Oral Cavity; Recurrent Basal Cell Carcinoma of the Lip; Recurrent Lymphoepithelioma of the Nasopharynx; Recurrent Lymphoepithelioma of the Oropharynx; Recurrent Mucoepidermoid Carcinoma of the Oral Cavity; Recurrent Salivary Gland Cancer; Recurrent Squamous Cell Carcinoma of the Larynx; Recurrent Squamous Cell Carcinoma of the Lip and Oral Cavity; Recurrent Squamous Cell Carcinoma of the Nasopharynx; Recurrent Squamous Cell Carcinoma of the Oropharynx; Recurrent Verrucous Carcinoma of the Larynx; Recurrent Verrucous Carcinoma of the Oral Cavity; Stage I Adenoid Cystic Carcinoma of the Oral Cavity; Stage I Basal Cell Carcinoma of the Lip; Stage I Lymphoepithelioma of the Nasopharynx; Stage I Lymphoepithelioma of the Oropharynx; Stage I Mucoepidermoid Carcinoma of the Oral Cavity; Stage I Salivary Gland Cancer; Stage I Squamous Cell Carcinoma of the Larynx; Stage I Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage I Squamous Cell Carcinoma of the Nasopharynx; Stage I Squamous Cell Carcinoma of the Oropharynx; Stage I Verrucous Carcinoma of the Larynx; Stage I Verrucous Carcinoma of the Oral Cavity; Stage II Adenoid Cystic Carcinoma of the Oral Cavity; Stage II Basal Cell Carcinoma of the Lip; Stage II Lymphoepithelioma of the Nasopharynx; Stage II Lymphoepithelioma of the Oropharynx; Stage II Mucoepidermoid Carcinoma of the Oral Cavity; Stage II Salivary Gland Cancer; Stage II Squamous Cell Carcinoma of the Larynx; Stage II Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage II Squamous Cell Carcinoma of the Nasopharynx; Stage II Squamous Cell Carcinoma of the Oropharynx; Stage II Verrucous Carcinoma of the Larynx; Stage II Verrucous Carcinoma of the Oral Cavity; Stage III Adenoid Cystic Carcinoma of the Oral Cavity; Stage III Basal Cell Carcinoma of the Lip; Stage III Lymphoepithelioma of the Nasopharynx; Stage III Lymphoepithelioma of the Oropharynx; Stage III Mucoepidermoid Carcinoma of the Oral Cavity; Stage III Salivary Gland Cancer; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage III Squamous Cell Carcinoma of the Nasopharynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage III Verrucous Carcinoma of the Oral Cavity; Stage IV Lymphoepithelioma of the Nasopharynx; Stage IV Squamous Cell Carcinoma of the Nasopharynx; Stage IVA Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVA Basal Cell Carcinoma of the Lip; Stage IVA Lymphoepithelioma of the Oropharynx; Stage IVA Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVA Salivary Gland Cancer; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVA Verrucous Carcinoma of the Oral Cavity; Stage IVB Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVB Basal Cell Carcinoma of the Lip; Stage IVB Lymphoepithelioma of the Oropharynx; Stage IVB Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVB Salivary Gland Cancer; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVB Verrucous Carcinoma of the Oral Cavity; Stage IVC Adenoid Cystic Carcinoma of the Oral Cavity; Stage IVC Basal Cell Carcinoma of the Lip; Stage IVC Lymphoepithelioma of the Oropharynx; Stage IVC Mucoepidermoid Carcinoma of the Oral Cavity; Stage IVC Salivary Gland Cancer; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Lip and Oral Cavity; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx; Stage IVC Verrucous Carcinoma of the Oral Cavity; Tongue Cancer

  2. Unusual presentation of total anomalous systemic venous connection.

    PubMed

    Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Pradhan, Priya M; Agarwal, Ravi

    2017-07-01

    A 9-year-old girl who presented with dyspnea on exertion was diagnosed with total anomalous systemic venous connection to the left atrium (both venae cavae), no left superior vena cava, and a moderate-sized atrial septal defect with severe pulmonary arterial hypertension and ectopic atrial rhythm. She underwent septation of the common atrium using autologous pericardium, thereby rerouting the superior vena cava, inferior vena cava, and coronary sinus to the right atrium. Her postoperative course was uneventful. This case is reported for its rarity of presentation with severe pulmonary arterial hypertension and ectopic atrial rhythm.

  3. Paclitaxel and Carboplatin Before Radiation Therapy With Paclitaxel in Treating HPV-Positive Patients With Stage III-IV Oropharynx, Hypopharynx, or Larynx Cancer

    ClinicalTrials.gov

    2017-04-19

    Human Papilloma Virus Infection; Stage III Squamous Cell Carcinoma of the Hypopharynx; Stage III Squamous Cell Carcinoma of the Larynx; Stage III Squamous Cell Carcinoma of the Oropharynx; Stage III Verrucous Carcinoma of the Larynx; Stage IV Squamous Cell Carcinoma of the Hypopharynx; Stage IV Verrucous Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Larynx; Stage IVA Squamous Cell Carcinoma of the Oropharynx; Stage IVA Verrucous Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Larynx; Stage IVB Squamous Cell Carcinoma of the Oropharynx; Stage IVB Verrucous Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Larynx; Stage IVC Squamous Cell Carcinoma of the Oropharynx; Stage IVC Verrucous Carcinoma of the Larynx

  4. Mice prefer draught-free housing.

    PubMed

    Krohn, T C; Hansen, A K

    2010-10-01

    An increasing number of rodents are housed in individually ventilated cage (IVC) systems, as these seem to be very effective for the protection of animals against infections, as well as protecting the staff against allergens. For the IVC systems to be properly ventilated, a huge amount of air has to be blown into the cage, which may cause a draught at animal level inside the cage. The aim of the present study was to evaluate the preferences of mice for differing levels of air speeds and air changes inside the cage. It has been concluded that mice do react to draughts, whereas they do not seem to be affected by a high number of air changes delivered without draught, which underlines the importance of applying draught-free IVC systems for mice.

  5. Ammonia Levels and Urine-Spot Characteristics as Cage-Change Indicators for High-Density Individually Ventilated Mouse Cages

    PubMed Central

    Washington, Ida M; Payton, Mark E

    2016-01-01

    Mouse cage and bedding changes are potentially stressful to mice and are also labor- and resource-intensive. These changes are often performed on a calendar-based schedule to maintain a clean microenvironment and limit the concentrations of ammonia to which mice and workers are exposed. The current study sought to establish a performance-based approach to mouse cage-changing that uses urine spot characteristics as visual indicators of intracage ammonia levels. Colorimetric ammonia indicators were used to measure ammonia levels in individually-ventilated cages (IVC) housing male or female mice (n =5 per cage) of various strains at 1 to 16 d after cage change. Urine spot characteristics were correlated with ammonia levels to create a visual indicator of the cage-change criterion of 25 ppm ammonia. Results demonstrated a consistent increase in ammonia levels with days since cage change, with cages reaching the cage-change criterion at approximately 10 d for IVC containing male mice and 16 d for those with female mice. Ammonia levels were higher for male than female mice but were not correlated with mouse age. However, urine spot diameter, color, and edge characteristics were strongly correlated with ammonia levels. Husbandry practices based on using urine spot characteristics as indicators of ammonia levels led to fewer weekly cage changes and concomitant savings in labor and resources. Therefore, urine spot characteristics can be used as visual indicators of intracage ammonia levels for use of a performance (urine spot)-based approach to cage-changing frequency that maintains animal health and wellbeing. PMID:27177558

  6. Vena cava filters and thrombolytic therapeutic monitoring based on functional near-infrared spectroscopy for deep vein thrombosis

    NASA Astrophysics Data System (ADS)

    Pan, Boan; Liu, Weichao; Fang, Xiang; Zhao, Ke; Li, Ting

    2018-02-01

    Deep vein thrombosis (DVT), happening in inpatients usually and especially with the postoperative population, is a serious disease characterized by an increased incidence. The venography is the golden standard to diagnose DVT. However, it involves invasive contrast agent injection and give patients physical and mental pressure. Functional nearinfrared spectroscopy (fNIRS) has been reported recently to diagnose DVT. Thrombolytic therapy activates the dissolution system with an exogenous activator that dissolves coronary thrombosis. The vena cava filter is a medical filter used for the treatment of thrombosis and the prevention of pulmonary embolism. Here we attempt to use portable NIRS for the DVT monitoring in the whole process of vena cava filter implantation and thrombolytic treatment, and contrast the patients of untreated, vena cava filter implantation and thrombolytic treatment. 19 DVT patients and 12 normal subjects were recruited. Thereinto, 7 patients have taken vena cava filter implantation, and 6 patients have taken the thrombolytic treatment. It was found that deoxyhemoglobins (Δ[Hb]) fluctuates and even increases in DVT. After vena cava filter implantation, Δ[Hb] increases first, then decreases. However, it emerges the rising trend and converge to the curves of normal subjects in thrombolytic treatment. The oxyhemoglobins (Δ[HbO2]) emerges opposite trend in most paradigms. The findings reveal the potential of fNIRS for monitoring DVT and therapeutic effect evaluation of thrombolysis and vena cava filters.

  7. Course of the inferior vena cava on lateral films exposed in different positions.

    PubMed

    Lien, H H; Bakke, S J

    1981-01-01

    The distance from the posterior border of the inferior vena cava to the anterior vertebral margin was measured in 100 presumably normal patients in the supine position. Seventeen of these were also examined in the right and left lateral positions and the changes in course of the vena cava compared with the supine position.

  8. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Hofmann, Eugen; Quick, Harald H; Kuehl, Hilmar; Aker, Stephanie; Kaiser, Gernot M; Borm, Paul J A; Jacob, Augustinus L; Bilecen, Deniz

    2009-05-01

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

  9. First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kos, Sebastian, E-mail: skos@gmx.d; Huegli, Rolf; Hofmann, Eugen

    The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. Themore » guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.« less

  10. A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions

    PubMed Central

    Montgomery, Jennifer P.; Kaufman, John A.

    2016-01-01

    Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration. PMID:27247475

  11. A Critical Review of Available Retrievable Inferior Vena Cava Filters and Future Directions.

    PubMed

    Montgomery, Jennifer P; Kaufman, John A

    2016-06-01

    Inferior vena cava filters have been placed in patients for decades for protection against pulmonary embolism. The widespread use of filters has dramatically increased owing at least in part to the approval of retrievable vena cava filters. Retrievable filters have the potential to protect against pulmonary embolism and then be retrieved once no longer needed to avoid potential long-term complications. There are several retrievable vena cava filters available for use. This article discusses the different filter designs as well as the published data on these available filters. When selecting a filter for use, it is important to consider the potential short-term complications and the filters' window for retrieval. Understanding potential long-term complications is also critical, as these devices are approved for permanent placement and many filters are not retrieved. Finally, this article will address research into new designs that may be the future of vena cava filtration.

  12. Effect of high-dose intravenous vitamin C on inflammation in cancer patients.

    PubMed

    Mikirova, Nina; Casciari, Joseph; Rogers, Andrea; Taylor, Paul

    2012-09-11

    An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer.Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels.Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods.CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment.There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein.Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels.In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted.

  13. The perioperative management of an inferior vena caval tumor thrombus in patients with renal cell carcinoma.

    PubMed

    Woodruff, Daniel Y; Van Veldhuizen, Peter; Muehlebach, Gregory; Johnson, Phillip; Williamson, Timothy; Holzbeierlein, Jeffrey M

    2013-07-01

    Inferior vena caval tumor thrombus (IVC-TT) occurs in 10% of patients diagnosed with renal cell carcinoma (RCC). The perioperative management of these patients remains challenging. Despite multiple publications outlining surgical approaches and outcomes there have been few studies detailing the best peri-operative management of patients with IVC-TT. Our goal was to define the optimal management of patients with RCC and IVC-TT. A review of all published literature regarding the management of RCC with IVC-TT was performed utilizing Pub Med and the Cochrane Database. Reviews were also made of all relevant literature regarding the need for cardiopulmonary bypass and recommendations regarding thrombus in any location in patients with malignancy. Specific items critically examined included: need for preoperative heart catheterization, need for anticoagulation and type of anticoagulation, need for additional studies such as lower extremity duplex or venogram, and indications for vena caval filter placement. The results were then presented to a multidisciplinary group made up of experts in the fields of Urology, Hematology, Oncology, Cardiothoracic Surgery, Interventional Radiology, and Pulmonary/Critical Care. Based on the available literature a best practice guidelines regarding the management of RCC with IVC-TT was established at our institution. Our institutional recommendations include (1) preoperative cardiac catheterization in all patients believed to require cardiopulmonary bypass for removal of the thrombus but only cardiac clearance for those who bypass is unlikely, (2) preoperative anticoagulation using a low molecular weight heparin such as enoxaparin unless contraindicated due to bleeding from the tumor or other contraindication, (3) avoidance of vena caval filters whenever possible is recommended due the potential for caval thrombosis and the difficulties they present during surgical resection. This study identified the available literature on the management of IVC-TT in association with RCC and was carefully reviewed by a multidisciplinary team. As a result, we have established a set of practice guidelines at our institution to help optimally manage patients with renal cell carcinoma and an inferior venal caval thrombus. Copyright © 2013 Elsevier Inc. All rights reserved.

  14. Effect of high-dose intravenous vitamin C on inflammation in cancer patients

    PubMed Central

    2012-01-01

    Background An inflammatory component is present in the microenvironment of most neoplastic tissues. Inflammation and elevated C-reactive protein (CRP) are associated with poor prognosis and decreased survival in many types of cancer. Vitamin C has been suggested as having both a preventative and therapeutic role in a number of pathologies when administered at much higher-than-recommended dietary allowance levels. Since in vitro studies demonstrated inhibition of pro-inflammatory pathways by millimolar concentrations of vitamin C, we decided to analyze the effects of high dose IVC therapy in suppression of inflammation in cancer patients. Methods 45 patients with prostate cancer, breast cancer, bladder cancer, pancreatic cancer, lung cancer, thyroid cancer, skin cancer and B-cell lymphoma were treated at the Riordan Clinic by high doses of vitamin C (7.5 g -50 g) after standard treatments by conventional methods. CRP and tumor markers were measured in serum or heparin-plasma as a routine analysis. In addition, serum samples were collected before and after the IVCs for the cytokine kit tests. Results According to our data positive response to treatment, which was demonstrated by measurements of C- reactive protein, was found in 75% of patients and progression of the inflammation in 25% of patients. IVC treatments on all aggressive stage cancer patients showed the poor response of treatment. There was correlation between tumor markers (PSA, CEA, CA27.29 and CA15-3) and changes in the levels of C-reactive protein. Our test of the effect of IVC on pro-inflammatory cytokines demonstrated that inflammation cytokines IL-1α, IL-2, IL-8, TNF-α, chemokine eotaxin and CRP were reduced significantly after treatments. Conclusions The high dose intravenous ascorbic acid therapy affects C-reactive protein levels and pro-inflammation cytokines in cancer patients. In our study, we found that modulation of inflammation by IVC correlated with decreases in tumor marker levels. In summary, our data support the hypothesis that high dose intravenous ascorbate treatments may reduce inflammation in cancer patients. Our results suggest that further investigations into the use of IVC to reduce inflammation in diseases where inflammation is relevant are warranted. PMID:22963460

  15. New data on selected Ivory Coast tektites

    USGS Publications Warehouse

    Cuttitta, F.; Carron, M.K.; Annell, C.S.

    1972-01-01

    Fourteen Ivory Coast tektites exhibit a range of bulk indices of refraction of 1.5156 to 1.5217 ?? 0.0004 and of bulk specific gravities of 2.428 to 2.502 ??0.005. Seven of these Ivory Coast (IVC) tektites were analyzed for major and minor element content. Compared to tektites from other strewn fields, their SiO2 content is low (67.2-69.1 %), A12O3 relatively high (15.8-16.8 %), and total iron relatively high but with a more restricted range (6.3-6.8 % as FeO). Their lime content is low (0.71-1.35%) compared to Australasian tektites but their MgO CaO ratio (about 3.1) is unusually high. All other tektite groups have Na2O K2O ratios less than unity, but the Na2O K2O ratio of the IVC tektites is slightly greater than unity. Their K Rb ratios range from 200 to 256 and average 227, which is higher than those determined for Australasian tektites, but similar to some obtained for moldavites. The Li content (41-48 ppm) is about the same as that of the Australasian tektites, but the Cs and Rb are lower, being 1.9 to 2.9 and 57 to 86 ppm, respectively. The IVC tektites are high in Cr (260-375 ppm), Co (19-25 ppm) and Ni (101-167 ppm), and particularly in Pb (<10-18 ppm), Cu (13-21 ppm) and Ga (14-23 ppm). The high Cr Ni ratios of the IVC tektites (range 2-3.6) are similar to those found for australites, philippinites and thailandites, but not the javanites and indochinites. Evaluation of these and other reported data show that compositional similarities between the IVC tektites and green or black Bosumtwi Crater glasses strongly support the hypothesis of a common impact origin-i.e. the Bosumtwi Crater site. Comparison of the IVC tektite composition with those of returned lunar materials (gabbros, basalts, breccia and soils) do not support a lunar origin for the Ivory Coast tektites. ?? 1972.

  16. The short-term efficacy of vena cava filters for the prevention of pulmonary embolism in patients with venous thromboembolism receiving anticoagulation: Meta-analysis of randomized controlled trials.

    PubMed

    Jiang, Jun; Jiao, Yuanyong; Zhang, Xiwei

    2017-10-01

    Objectives To perform a meta-analysis of randomized controlled trials assessing the effectiveness of inferior vena cava filters in patients with deep vein thrombosis for preventing pulmonary embolism. Method Relevant randomized controlled trials of inferior vena cava filters for the prevention of pulmonary embolism were identified by searching electronic databases updated in February 2016. Relative risks of recurrent pulmonary embolism, recurrent deep vein thrombosis, and mortality at three months were analyzed. Results Three published randomized controlled trials were included involving a total of 863 deep vein thrombosis patients. No significant differences were detected with inferior vena cava filters placement with regard to the incidence of recurrent pulmonary embolism or fatal pulmonary embolism. There were also no significant differences in the incidence of recurrent deep vein thrombosis or mortality with inferior vena cava filters placement at three months. Conclusions Inferior vena cava filter in addition to anticoagulation was not associated with a reduction in the incidence of recurrent pulmonary embolism as compared with anticoagulation alone in patients with deep vein thrombosis in the short term.

  17. Effect of Pseudomonas aeruginosa on sperm capacitation and protein phosphorylation of boar spermatozoa.

    PubMed

    Sepúlveda, Lilian; Bussalleu, Eva; Yeste, Marc; Bonet, Sergi

    2016-05-01

    Several studies have reported the detrimental effects that bacteriospermia causes on boar sperm quality, but little is known about its effects on IVC. Considering that, the present study sought to evaluate the effects of different concentrations of Pseudomonas aeruginosa on different indicators of capacitation status (sperm viability, membrane lipid disorder, sperm motility kinematics, and protein phosphorylation of boar spermatozoa) after IVC. Flow cytometry and computer assisted sperm analysis (CASA) revealed that the presence of P aeruginosa in boar sperm samples, mostly at concentrations greater than 10(6) CFU/mL, is associated with a significant (P < 0.05) decrease in the percentages of both sperm membrane integrity and sperm with low membrane lipid disorder, and also with a reduction in sperm motility kinetic parameters when compared with results obtained from the control sample, which presented the typical motility pattern of capacitated-like boar spermatozoa. Moreover, Western blot results also showed significant (P < 0.05) changes in the levels of tyrosine, serine, and threonine protein phosphorylation because of bacterial contamination, the decrease in phosphotyrosine levels of p32, a well-known marker of IVC achievement in boar sperm, being the most relevant. Indeed, after 3 hours of IVC, phosphotyrosine levels of p32 in the control sample were 3.13 ± 0.81, whereas in the tubes with 10(6) and 10(8) CFU/mL were 1.05 ± 0.20 and 0.36 ± 0.07, respectively. Therefore, the present study provides novel data regarding the effects of bacterial contamination on boar sperm, suggesting that the presence of P aeruginosa affects the fertilizing ability of boar sperm by altering its ability to accomplish IVC. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters.

    PubMed

    Heiligers-Duckers, Connie; Peters, Nathalie A L R; van Dijck, Jose J P; Hoeijmakers, Jan M J; Janssen, Marcel J W

    2013-08-01

    In-vitro hemolysis is a great challenge to emergency departments where blood is drawn from intravenous catheters (IVCs). Although high quality samples can be obtained by straight needle venipuncture, IVCs are preferred for various reasons. The aim of this study was to identify blood collection practices that reduce hemolysis while using IVC. The study was conducted at an emergency department where blood is drawn in ≥ 90% of patients from IVC. Hemolysis, measured spectrophotometrically, was compared between syringe and vacuum tubes. The following practices were tested in combination with vacuum collection; a Luer-slip adapter, a Luer-lock adapter, discard tubes and low vacuum tubes. Each intervention lasted 1 week and retrieved 154 to 297 samples. As reference, hemolysis was also measured in vacuum tubes retrieved from departments where only straight needle venipuncture is performed. Vacuum collection led to more hemolytic samples compared with syringe tubes (24% versus 16% respectively, p=0.008). No difference in hemolysis was observed between the Luer-slip and the Luer-lock adapter. The use of discard (17% hemolytic, p=0.045) and low vacuum tubes (12% hemolytic, p<0.001) substantially decreased hemolysis. None of the interventions reduced the hemolysis rate to the level observed when drawing blood by straight needle venipuncture (3%, p<0.02). In summary, both discard and low vacuum tubes reduce hemolysis while drawing blood from IVC. Of these practices the use of a low vacuum tube is preferred considering the less volume of blood and the amount of tubes drawn. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Management and outcome of patients with acute myocardial infarction presenting with pacemaker rhythm.

    PubMed

    Bertel, Noemi; Witassek, Fabienne; Puhan, Milo; Erne, Paul; Rickli, Hans; Naegeli, Barbara; Pedrazzini, Giovanni; Stauffer, Jean-Christophe; Radovanovic, Dragana

    2017-03-01

    Diagnosis of acute myocardial infarction (MI) is challenging in pacemaker patients. Little is known about this patient group. Patients with MI enrolled in the Swiss national AMIS Plus registry between January 2005 and December 2015 were analyzed. All patients with either paced ventricular rhythm or sinus rhythm with intrinsic ventricular conduction (IVC) were included in this study. Outcomes using crude data and propensity score matching were compared between patients with pacemaker rhythm and patients with IVC. The primary endpoint was in-hospital death. Data from 300 patients with paced rhythm and 27,595 with IVC were analyzed. Patients with pacemaker rhythm were older (78.2y vs 65.4y; p<0.001), had more comorbidities (Charlson Index (CCI)>1: 54.0% vs 21.1%; p<0.001) and a higher rate of heart failure upon presentation (Killip class>2, 11.0% vs 5.9%; p<0.001) compared to patients with IVC. Door to balloon time in patients undergoing acute PCI is markedly delayed in contrast to patients with IVC (280min vs 85min; p<0.001). Consequently, crude mortality in patients with pacemakers was high (11.3% vs 4.6%; p<0.001). However, when analyzed with propensity matching for gender, age, CCI>1 and Killip>2, mortality was similar (11.2% vs 10.5%; p=0.70). Pacemaker patients with acute MI represent a high-risk group with doubled crude mortality compared to patients without pacemakers, due to higher age and higher Killip class. Diagnosis is difficult and results in delayed treatment. Treatment algorithms for MI with paced rhythm should possibly be adapted to those used for STEMI or new left bundle branch block. NCT01305785. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.

    PubMed

    Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F

    2003-11-01

    To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.

  1. Indications, complications and outcomes of inferior vena cava filters: A retrospective study.

    PubMed

    Wassef, Andrew; Lim, Wendy; Wu, Cynthia

    2017-05-01

    Inferior vena cava filters are used to prevent embolization of a lower extremity deep vein thrombosis when the risk of pulmonary embolism is thought to be high. However, evidence is lacking for their benefit and guidelines differ on the recommended indications for filter insertion. The study aim was to determine the reasons for inferior vena cava filter placement and subsequent complication rate. A retrospective cohort of patients receiving inferior vena cava filters in Edmonton, Alberta, Canada from 2007 to 2011. Main outcome was the indication of inferior vena cava filter insertion. Other measures include baseline demographic and medical history of patients, clinical outcomes and filter retrieval rates. 464 patients received inferior vena cava filters. An acute deep vein thrombosis with a contraindication to anticoagulation was the indication for 206 (44.4%) filter insertions. No contraindication to anticoagulation could be identified in 20.7% of filter placements. 30.6% were placed in those with active cancer, in which mortality was significantly higher. Only 38.9% of retrievable filters were successfully retrieved. Inferior vena cava filters were placed frequently in patients with weak or no guideline-supported indications for filter placement and in up to 20% of patients with no contraindication to anticoagulation. The high rates of cancer and the high mortality rate of the cohort raise the possibility that some filters are placed inappropriately in end of life settings. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Linear ablation of right atrial free wall flutter: demonstration of bidirectional conduction block as an endpoint associated with long-term success.

    PubMed

    Snowdon, Richard L; Balasubramaniam, Richard; Teh, Andrew W; Haqqani, Haris M; Medi, Caroline; Rosso, Raphael; Vohra, Jitendra K; Kistler, Peter M; Morton, Joseph B; Sparks, Paul B; Kalman, Jonathan M

    2010-05-01

    Ablation for atypical atrial flutter (AFL) is often performed during tachycardia, with termination or noninducibility of AFL as the endpoint. Termination alone is, however, an inadequate endpoint for typical AFL ablation, where incomplete isthmus block leads to high recurrence rates. We assessed conduction block across a low lateral right atrial (RA) ablation line (LRA) from free wall scar to the inferior vena cava (IVC) or tricuspid annulus in 11 consecutive patients with atypical RA free wall flutter. LRA block was assessed following termination of AFL, by pacing from the ablation catheter in the low lateral RA posterior to the ablation line and recording the sequence and timing of activation anterior to the line with a duodecapole catheter, and vice versa for bidirectional block. LRA block resulted in a high to low activation pattern on the halo and a mean conduction time of 201 +/- 48 ms to distal halo. LRA conduction block was present in only 2 out of 6 patients after termination of AFL by ablation. Ablation was performed during sinus rhythm (SR) in 9 patients to achieve LRA conduction block. No recurrence of AFL was observed at long-term follow-up (22 +/- 12 months); 3 patients developed AF. Termination of right free wall flutter is often associated with persistent LRA conduction and additional radiofrequency ablation (RFA) in SR is usually required. Low RA pacing may be used to assess LRA conduction block and offers a robust endpoint for atypical RA free wall flutter ablation, which results in a high long-term cure rate.

  3. The Role of Computational Modeling and Simulation in the Total Product Life Cycle of Peripheral Vascular Devices

    PubMed Central

    Morrison, Tina M.; Dreher, Maureen L.; Nagaraja, Srinidhi; Angelone, Leonardo M.; Kainz, Wolfgang

    2018-01-01

    The total product life cycle (TPLC) of medical devices has been defined by four stages: discovery and ideation, regulatory decision, product launch, and postmarket monitoring. Manufacturers of medical devices intended for use in the peripheral vasculature, such as stents, inferior vena cava (IVC) filters, and stent-grafts, mainly use computational modeling and simulation (CM&S) to aid device development and design optimization, supplement bench testing for regulatory decisions, and assess postmarket changes or failures. For example, computational solid mechanics and fluid dynamics enable the investigation of design limitations in the ideation stage. To supplement bench data in regulatory submissions, manufactures can evaluate the effects of anatomical characteristics and expected in vivo loading environment on device performance. Manufacturers might also harness CM&S to aid root-cause analyses that are necessary when failures occur postmarket, when the device is exposed to broad clinical use. Once identified, CM&S tools can then be used for redesign to address the failure mode and re-establish the performance profile with the appropriate models. The Center for Devices and Radiological Health (CDRH) wants to advance the use of CM&S for medical devices and supports the development of virtual physiological patients, clinical trial simulations, and personalized medicine. Thus, the purpose of this paper is to describe specific examples of how CM&S is currently used to support regulatory submissions at different phases of the TPLC and to present some of the stakeholder-led initiatives for advancing CM&S for regulatory decision-making. PMID:29479395

  4. The Role of Computational Modeling and Simulation in the Total Product Life Cycle of Peripheral Vascular Devices.

    PubMed

    Morrison, Tina M; Dreher, Maureen L; Nagaraja, Srinidhi; Angelone, Leonardo M; Kainz, Wolfgang

    2017-01-01

    The total product life cycle (TPLC) of medical devices has been defined by four stages: discovery and ideation, regulatory decision, product launch, and postmarket monitoring. Manufacturers of medical devices intended for use in the peripheral vasculature, such as stents, inferior vena cava (IVC) filters, and stent-grafts, mainly use computational modeling and simulation (CM&S) to aid device development and design optimization, supplement bench testing for regulatory decisions, and assess postmarket changes or failures. For example, computational solid mechanics and fluid dynamics enable the investigation of design limitations in the ideation stage. To supplement bench data in regulatory submissions, manufactures can evaluate the effects of anatomical characteristics and expected in vivo loading environment on device performance. Manufacturers might also harness CM&S to aid root-cause analyses that are necessary when failures occur postmarket, when the device is exposed to broad clinical use. Once identified, CM&S tools can then be used for redesign to address the failure mode and re-establish the performance profile with the appropriate models. The Center for Devices and Radiological Health (CDRH) wants to advance the use of CM&S for medical devices and supports the development of virtual physiological patients, clinical trial simulations, and personalized medicine. Thus, the purpose of this paper is to describe specific examples of how CM&S is currently used to support regulatory submissions at different phases of the TPLC and to present some of the stakeholder-led initiatives for advancing CM&S for regulatory decision-making.

  5. Iodine I-131 With or Without Selumetinib in Treating Patients With Recurrent or Metastatic Thyroid Cancer

    ClinicalTrials.gov

    2018-05-15

    Metastatic Thyroid Gland Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage IV Thyroid Gland Follicular Carcinoma; Stage IV Thyroid Gland Papillary Carcinoma; Stage IVA Thyroid Gland Follicular Carcinoma; Stage IVA Thyroid Gland Papillary Carcinoma; Stage IVB Thyroid Gland Follicular Carcinoma; Stage IVB Thyroid Gland Papillary Carcinoma; Stage IVC Thyroid Gland Follicular Carcinoma; Stage IVC Thyroid Gland Papillary Carcinoma

  6. [Crops: Classifying, Selecting, Harvesting, Grading, and Packing.] Student Materials. V.A. III. [IV-B-1 through IV-B-2; IV-C-1 through IV-C-2].

    ERIC Educational Resources Information Center

    Texas A and M Univ., College Station. Vocational Instructional Services.

    Part of a series of eight student learning modules in vocational agriculture, this booklet deals with crop-related activities. The first section is on harvesting methods and equipment. The following portions address the handling, grading, and packing of crops; and the classification and selection of fruits, vegetables, and ornamental plants. There…

  7. Prepare to Care, A Supported Self-Management Intervention for Head and Neck Cancer CaregiversHead and Neck Cancer

    ClinicalTrials.gov

    2018-04-26

    Caregiver; Malignant Head and Neck Neoplasm; Paranasal Sinus Squamous Cell Carcinoma; Salivary Gland Squamous Cell Carcinoma; Stage I Hypopharyngeal Squamous Cell Carcinoma; Stage I Laryngeal Squamous Cell Carcinoma; Stage I Lip and Oral Cavity Squamous Cell Carcinoma; Stage I Oropharyngeal Squamous Cell Carcinoma; Stage II Hypopharyngeal Squamous Cell Carcinoma; Stage II Laryngeal Squamous Cell Carcinoma; Stage II Lip and Oral Cavity Squamous Cell Carcinoma; Stage II Oropharyngeal Squamous Cell Carcinoma; Stage III Hypopharyngeal Squamous Cell Carcinoma; Stage III Laryngeal Squamous Cell Carcinoma; Stage III Lip and Oral Cavity Squamous Cell Carcinoma; Stage III Oropharyngeal Squamous Cell Carcinoma; Stage IV Hypopharyngeal Squamous Cell Carcinoma; Stage IV Laryngeal Squamous Cell Carcinoma; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma; Stage IV Oropharyngeal Squamous Cell Carcinoma; Stage IVA Hypopharyngeal Squamous Cell Carcinoma; Stage IVA Laryngeal Squamous Cell Carcinoma; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVA Oropharyngeal Squamous Cell Carcinoma; Stage IVB Hypopharyngeal Squamous Cell Carcinoma; Stage IVB Laryngeal Squamous Cell Carcinoma; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVB Oropharyngeal Squamous Cell Carcinoma; Stage IVC Hypopharyngeal Squamous Cell Carcinoma; Stage IVC Laryngeal Squamous Cell Carcinoma; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma; Stage IVC Oropharyngeal Squamous Cell Carcinoma

  8. 1995 Toxic Hazards Research Unit Annual Report.

    DTIC Science & Technology

    1996-07-01

    cabinet, the bile duct is cannulated using PE-10 tubing, the portal vein and inferior vena cava (above the diaphragm) are both cannulated with 16...homogenate in saline. Rats used to determine partition coefficients were euthanatized with C02. Blood was collected from the posterior vena cava ...sampled for histopathologic examination. Blood was sampled via the vena cava for clinical chemistry evaluations and whole livers were weighed at

  9. Non-Invasive Methods of Cardiovascular Exploration in Aerospace Medicine.

    DTIC Science & Technology

    1983-12-01

    inferior vena cava Aorta right atrium filling chamber of right ventricle. Trunk of pulmonary art cry Posterior border: almost vertical AP lower arch left ... left ventricle. Inferior Vena cava infundihbulum L Upper border aortic arch Lower border superimposed borders of the RV LV right and left ventricles...iliac aneurisms is possible. isotopic phlebography is useful in the investigation of the permeability of the inferior vena cava

  10. Isolated Right Superior Vena Cava Drainage into the Left Atrium Diagnosed Noninvasively in the Peripartum Period

    PubMed Central

    Baggett, Charles; Skeen, Shawn J.; Gantt, D. Scott; Trotter, Bradley R.; Birkemeier, Krista L.

    2009-01-01

    Isolated right superior vena cava drainage into the left atrium is an extremely rare cardiac anomaly, especially in the absence of other cardiac abnormalities. Only 28 of 5,127 reported consecutive congenital cardiac cases involved superior vena cava drainage into the left atrium, and all were associated with other cardiac anomalies. Of 19 reported cases of right superior vena cava drainage into the left atrium, most patients have been children who were experiencing mild hypoxemia and cyanosis. Herein, we describe the case of a 34-year-old woman who presented with asymptomatic hypoxemia in the peripartum period. She was diagnosed to have isolated drainage of the right superior vena cava into the left atrium. To the best of our knowledge, this is the 1st reported instance of such diagnosis by use of noninvasive imaging only, without cardiac catheterization. We also review the medical literature that pertains to our patient's anomaly. PMID:20069093

  11. Exploiting biological activities of brown seaweed Ecklonia cava for potential industrial applications: a review.

    PubMed

    Wijesinghe, W A J P; Jeon, You-Jin

    2012-03-01

    Seaweeds are rich in vitamins, minerals, dietary fibres, proteins, polysaccharides and various functional polyphenols. Many researchers have focused on brown algae as a potential source of bioactive materials in the past few decades. Ecklonia cava is a brown seaweed that is abundant in the subtidal regions of Jeju Island in the Republic of Korea. This seaweed attracted extensive interest due to its multiple biological activities. E. cava has been identified as a potential producer of wide spectrum of natural substances such as carotenoids, fucoidans and phlorotannins showing different biological activities in vital industrial applications including pharmaceutical, nutraceutical, cosmeceutical and functional food. This review focuses on biological activities of the brown seaweed E. cava based on latest research results, including antioxidant, anticoagulative, antimicrobial, antihuman immunodeficiency virus, anti-inflammatory, immunomodulatory, antimutagenic, antitumour and anticancer effects. The facts summarized here may provide novel insights into the functions of E. cava and its derivatives and potentially enable their use as functional ingredients in potential industrial applications.

  12. Role of cardiac output and the autonomic nervous system in the antinatriuretic response to acute constriction of the thoracic superior vena cava.

    NASA Technical Reports Server (NTRS)

    Schrier, R. W.; Humphreys, M. H.; Ufferman, R. C.

    1971-01-01

    Study of the differential characteristics of hepatic congestion and decreased cardiac output in terms of potential afferent stimuli in the antinatriuretic effect of acute thoracic inferior vena cava (TIVC) constriction. An attempt is made to see if the autonomic nervous system is involved in the antinatriuretic effect of acute TIVC or thoracic superior vena cava constriction.

  13. Large left circumflex coronary artery with a fistula to superior vena cava: Diagnosis by echocardiography.

    PubMed

    Liu, Yunqi; Liu, Yanqiu; Xiong, Mai; Li, Hanzhao; Liu, Donghong; Zhang, Xi

    2017-04-01

    The left circumflex coronary artery associated with a fistula to superior vena cava is a rare entity. We describe a 7-year-old girl who presented with a cardiac murmur and was diagnosed with a coronary artery fistula between the left circumflex artery and superior vena cava by echocardiography. The surgical occlusion of the fistula was successful. © 2017, Wiley Periodicals, Inc.

  14. Surgical management of the left superior vena cava draining into the left atrium: a novel off-pump technique using the left atrial appendage

    PubMed Central

    Boutayeb, Alaae; Marmade, Lahcen; Bensouda, Adil; Moughil, Said

    2012-01-01

    The left superior vena cava is the most common congenital venous anomaly in the chest; however, its drainage into the left atrium is exceptional. The aim of the paper is to describe our novel technique to connect the left superior vena cava to the right cavities using the left atrial appendage, without cardiopulmonary bypass. PMID:22802356

  15. Annual Progress Report Fiscal Year 1989

    DTIC Science & Technology

    1989-09-30

    thopaedics, Las Vegas, NV, February, 1989 clusion of the common iliac veins and inferior vena cava H following vaginal hysterectomy. A case report...The aorta and inferior vena cava will be transected and cannulated. Using techniques prescribed in the Microill product literature the aorta and both...via the inferior vena cava . At that point the animals will be refrigerated to allow overnight curing of the Microfil. As each animal has had only one

  16. The Use of Hypertonic Solutions to Resuscitate Animals from Hypovolemic Shock.

    DTIC Science & Technology

    1986-03-18

    halothane/nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed...and on skeletal muscle inferior vena cava . Heart rate was recorded resting transmembrane potentials. These ef- and blood press.ure was monitored with...nitrous oxide and surgically prepared with chronic cannulations of the thoracic aorta and superior vena cava using silastic catheters placed through a

  17. Radical robot-assisted laparoscopic nephrectomy with thrombectomy in the vena cava.

    PubMed

    Estébanez Zarranz, J; Belloso Loidi, J; Gutierrez García, M A; Rubio Calaveras, V; Morales Higelmo, G; Melendo Tercilla, P; Busto Leis, L; Sanz Jaka, J P

    2018-04-23

    Renal cell carcinoma has a natural tendency to extend through the renal vein. When the thrombus reaches the vena cava, thrombectomy and the necessary reconstruction of the vena cava are typically performed by open pathway. Robot-assisted technology provides advantages for performing this complex technique, using a minimally invasive access. We present the technique we employed in the first case performed in our department. After performing renal artery embolisation, we conducted the surgery with the Vinci S robotic system. The main steps of the surgery are as follows: detachment and Kocher manoeuvre; release of the lower renal pole; clamping and sectioning of the renal artery; endocavitary ultrasound to locate the thrombus; placement of tourniquets in the vena cava below and above the renal veins and in the left renal vein; closure of the 3 tourniquets; opening of the vena cava; resection and extraction of the thrombus; suture of the vena cava; opening of the tourniquets; complete release of the kidney; bagging and extraction of the specimen. The surgery was performed without complications. The patient required a transfusion of 2 units of packed red blood cells and was discharged with modest renal failure (creatinine level of 1.60mg/dl). Radical nephrectomy with thrombectomy in the vena cava is a technique susceptible to severe complications and has, to date, been performed in few centres. We believe that the technique is reproducible and has clear advantages for our patients. Copyright © 2018 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Effects of Ecklonia cava as fucoidan-rich algae on growth performance, nutrient digestibility, intestinal morphology and caecal microflora in weanling pigs.

    PubMed

    Choi, Yohan; Hosseindoust, Abdolreza; Goel, Akshat; Lee, Suhyup; Jha, Pawan Kumar; Kwon, Ill Kyong; Chae, Byung-Jo

    2017-01-01

    In the present study, role of increasing levels of Ecklonia cava (seaweed) supplementation in diets was investigated on growth performance, coefficient of total tract apparent digestibility (CTTAD) of nutrients, serum immunoglobulins, cecal microflora and intestinal morphology of weanling pigs. A total of 200 weaned pigs (Landrace×Yorkshire×Duroc; initial body weight 7.08±0.15 kg) were randomly allotted to 4 treatments on the basis of body weight. There were 5 replicate pens in each treatment including 10 pigs of each. Treatments were divided by dietary Ecklonia cava supplementation levels (0%, 0.05%, 0.1%, or 0.15%) in growing-finishing diets. There were 2 diet formulation phases throughout the experiment. The pigs were offered the diets ad libitum for the entire period of experiment in meal form. The pigs fed with increasing dietary concentrations of Ecklonia cava had linear increase (p<0.05) in the overall average daily gain, however, there were no significant differences in gain to feed ratio, CTTAD of dry matter and crude protein at both phase I and phase II. Digestibility of gross energy was linearly improved (p<0.05) in phase II. At day 28, pigs fed Ecklonia cava had greater (linear, p<0.05) Lactobacillus spp., fewer Escherichia coli ( E. coli ) spp. (linear, p<0.05) and a tendency to have fewer cecal Clostridium spp. (p = 0.077). The total anaerobic bacteria were not affected with supplementation of Ecklonia cava in diets. Polynomial contrasts analysis revealed that villus height of the ileum exhibited a linear increase (p<0.05) in response with the increase in the level of dietary Ecklonia cava . However, villus height of duodenum and jejunum, crypt depth, villus height to crypt depth ratio of different segments of the intestine were not affected. The results suggest that Ecklonia cava had beneficial effects on the growth performance, cecal microflora, and intestinal morphology of weanling pigs.

  19. Lenvatinib and Pembrolizumab in DTC

    ClinicalTrials.gov

    2018-05-21

    Columnar Cell Variant Thyroid Gland Papillary Carcinoma; Follicular Variant Thyroid Gland Papillary Carcinoma; Poorly Differentiated Thyroid Gland Carcinoma; Recurrent Thyroid Gland Carcinoma; Stage III Differentiated Thyroid Gland Carcinoma AJCC v7; Stage III Thyroid Gland Follicular Carcinoma AJCC v7; Stage III Thyroid Gland Papillary Carcinoma AJCC v7; Stage IV Thyroid Gland Follicular Carcinoma AJCC v7; Stage IV Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVA Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVA Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVA Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVB Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVB Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVB Thyroid Gland Papillary Carcinoma AJCC v7; Stage IVC Differentiated Thyroid Gland Carcinoma AJCC v7; Stage IVC Thyroid Gland Follicular Carcinoma AJCC v7; Stage IVC Thyroid Gland Papillary Carcinoma AJCC v7; Tall Cell Variant Thyroid Gland Papillary Carcinoma; Thyroid Gland Oncocytic Follicular Carcinoma

  20. Vena caval impalement: an unusual lawn mower injury in a child.

    PubMed

    Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P

    1998-06-01

    Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.

  1. Study on virtual instrument developing system based on intelligent virtual control

    NASA Astrophysics Data System (ADS)

    Tang, Baoping; Cheng, Fabin; Qin, Shuren

    2005-01-01

    The paper introduces a non-programming developing system of a virtual instument (VI), i.e., a virtual measurement instrument developing system (VMIDS) based on intelligent virtual control (IVC). The background of the IVC-based VMIDS is described briefly, and the hierarchical message bus (HMB)-based software architecture of VMIDS is discussed in detail. The three parts and functions of VMIDS are introduced, and the process of non-programming developing VI is further described.

  2. Can intravenous conscious sedation with midazolam be effective at facilitating surgical dentistry in adolescent orthodontic patients? - A service evaluation

    PubMed Central

    Stamp, A.J.; Dorman, M.L.; Vernazza, C.R.; Deeming, G.; Reid, C.; Wilson, K.E.; Girdler, N.M.

    2017-01-01

    Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care is often provided under GA. Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine its use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care. Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS midazolam. Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescent, 98.9% (n=172) allowed cannulation with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7mg with 79.1% patients having good or excellent co-operation and three minor adverse events occurring. Conclusion This service evaluation shows IVCS midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA. PMID:28127013

  3. Ficlatuzumab With or Without Cetuximab in Treating Patients With Cetuximab-Resistant, Recurrent or Metastatic Head and Neck Squamous Cell Carcinoma

    ClinicalTrials.gov

    2018-02-02

    Head and Neck Basaloid Carcinoma; Recurrent Head and Neck Squamous Cell Carcinoma; Recurrent Oropharyngeal Squamous Cell Carcinoma; Squamous Cell Carcinoma of Unknown Primary Origin; Stage IV Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IV Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IV Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IV Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVA Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVA Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVA Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVA Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVB Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVB Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVB Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVB Oropharyngeal Squamous Cell Carcinoma AJCC v7; Stage IVC Lip and Oral Cavity Squamous Cell Carcinoma AJCC v6 and v7; Stage IVC Nasal Cavity and Paranasal Sinus Squamous Cell Carcinoma AJCC v7; Stage IVC Nasopharyngeal Keratinizing Squamous Cell Carcinoma AJCC v7; Stage IVC Oropharyngeal Squamous Cell Carcinoma AJCC v7; Head and Neck Cancer; Oropharyngeal Cancer; HNSCC

  4. Can intravenous conscious sedation with midazolam be effective at facilitating surgical dentistry in adolescent orthodontic patients? A service evaluation.

    PubMed

    Stamp, A J; Dorman, M L; Vernazza, C R; Deeming, G; Reid, C; Wilson, K E; Girdler, N M

    2017-01-27

    Background Surgical dentistry during orthodontic care often occurs in adolescence and may involve surgical removal or exposure of teeth. The invasive nature of treatment, combined with dental anxiety, means care can often be provided under general anaesthesia (GA). Best-practice guidelines however endorse conscious sedation as an alternative, where appropriate. Although a limited number of studies have shown safe and effective use of intravenous conscious sedation (IVCS) with midazolam in this cohort, robust evidence to support routine use is lacking. Aim To assess whether IVCS with midazolam can effectively facilitate surgical dentistry in adolescent orthodontic patients in primary care.Method A retrospective service evaluation was undertaken reviewing clinical records of adolescents (aged 12-15 years) undergoing surgical exposure and/or surgical removal of teeth under IVCS with midazolam.Results A total of 174 adolescents (mean age 14.2 years) attended for treatment between 2009 and 2015. Of these adolescents, 98.9% (N = 172) allowed cannulation, with all surgical dentistry completed during a single visit. Midazolam dose ranged from 2-7 mg with 79.1% of patients having good or excellent cooperation and three minor adverse events occurring.Conclusion This service evaluation shows IVCS with midazolam can effectively facilitate surgical orthodontics in carefully selected adolescents. There is however a distinct need to further explore potential for this technique to provide a viable alternative to GA.

  5. Design Optimization of Vena Cava Filters: An application to dual filtration devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singer, M A; Wang, S L; Diachin, D P

    Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped modelmore » thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.« less

  6. ISOLATED ANOMALOUS INFERIOR VENA CAVA CONNECTION TO THE LEFT ATRIUM: REPORT OF A SUCCESSFUL SURGICAL CASE AND REVIEW OF THE LITERATURE.

    PubMed

    Richardson, James V.; Doty, Donald B.

    1979-03-01

    This report describes a rare case of isolated anomalous connection of the inferior vena cava to the left atrium. Patching of a surgically-created atrial septal defect and rerouting of caval drainage ino the right atrium effected a successful correction. This case brings to 18 the total number of reported cases in the literature in which the inferior vena cava was connected to the left atrium.

  7. Clinical Investigation Program.

    DTIC Science & Technology

    1979-10-01

    It has been established by a series of dog experiments using the-e-e-ctromagnetic flow meter that the blood flow in the inferior vena cava between...by thermodilution. Hepatic vein blood flow could be estimated by subtraction of the blood flow in the vena cava at the level of the renal veins from...the vena cava blood flow at the level of the diaphragm. This should be liver blood flow. It should be possible to sample pure hepatic vein blood by

  8. Cardiac Ischemia Model for +Gz Using Miniature Swine and Baboons

    DTIC Science & Technology

    2008-04-01

    VAP was tunneled subcutaneously to an incision in the ventral neck and placed in the superior vena cava just craniad to the right atrium through...was passed transcutaneously to the su- perior vena cava from the arm or to the inferior vena cava from the lower leg, using fl uoroscopy. The...Five control swine were maintained on a standard swine diet. Also, nine male baboons had a constrictor placed around the left anterior descending

  9. Structural and Functional Differences Between Porcine Aorta and Vena Cava.

    PubMed

    Mattson, Jeffrey M; Zhang, Yanhang

    2017-07-01

    Elastin and collagen fibers are the major load-bearing extracellular matrix (ECM) constituents of the vascular wall. Arteries function differently than veins in the circulatory system; however as a result from several treatment options, veins are subjected to sudden elevated arterial pressure. It is thus important to recognize the fundamental structure and function differences between a vein and an artery. Our research compared the relationship between biaxial mechanical function and ECM structure of porcine thoracic aorta and inferior vena cava. Our study suggests that aorta contains slightly more elastin than collagen due to the cyclical extensibility, but vena cava contains almost four times more collagen than elastin to maintain integrity. Furthermore, multiphoton imaging of vena cava showed longitudinally oriented elastin and circumferentially oriented collagen that is recruited at supraphysiologic stress, but low levels of strain. However in aorta, elastin is distributed uniformly, and the primarily circumferentially oriented collagen is recruited at higher levels of strain than vena cava. These structural observations support the functional finding that vena cava is highly anisotropic with the longitude being more compliant and the circumference stiffening substantially at low levels of strain. Overall, our research demonstrates that fiber distributions and recruitment should be considered in addition to relative collagen and elastin contents. Also, the importance of accounting for the structural and functional differences between arteries and veins should be taken into account when considering disease treatment options.

  10. Inferior Vena Cava Filters in Patients with Acute Pulmonary Embolism and Cancer.

    PubMed

    Stein, Paul D; Matta, Fadi; Lawrence, Frank R; Hughes, Mary J

    2018-04-01

    Administrative data have shown a lower mortality in hospitalized patients with pulmonary embolism and cancer who receive a vena cava filter. In the absence of a randomized controlled trial of vena cava filters in such patients, further investigation is necessary. Therefore, we performed this investigation using administrative data from a different database than used previously, and we investigate patients hospitalized in more recent years. We analyzed administrative data from the Premier Healthcare Database, 2010-2014, in patients hospitalized with pulmonary embolism and solid malignant tumors. Patients were identified on the basis of International Classification of Disease, Ninth Revision, Clinical Modification codes. Patients aged >60 years had a lower in-hospital all-cause mortality with vena cava filters than those who did not have filters, 346 of 4648 (7.4%) compared with 2216 of 19,847 (11.2%) (P < .0001) (relative risk 0.67). Among patients aged >60 years who received an inferior vena cava, all-cause mortality within 3 months was 704 of 4648 (15.1%), compared with 3444 of 19,847 (17.4%) among those who did not receive a filter (P < .0001) (relative risk 0.86). Elderly patients with pulmonary embolism and cancer may be a special population in whom inferior vena cava filters reduce in-hospital and 3-month all-cause mortality. Further investigation is needed, particularly in younger patients. Copyright © 2018. Published by Elsevier Inc.

  11. Vena Cava 3D Contrast-Enhanced MR Venography: A Pictorial Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin Jiang; Zhou Kangrong; Chen Zuwang

    Three-dimensional contrast-enhanced magnetic resonance venography (CE MRV) is a sensitive and accurate method for diagnosing vena cava pathologies. The commonly used indirect approach involves a nondiluted gadolinium contrast agent injected into an upper limb vein or, occasionally, a pedal vein for assessment of the superior or inferior vena cava. In our studies, a coronal 3D fast multi-planar spoiled gradient-echo acquisition was used. A pre-contrast scan was obtained to ensure correct coverage of the region of interest. We initiated contrast-enhanced acquisition 15 sec after the start of contrast agent injection and performed the procedure twice. The image sets were obtained duringmore » two 20-30-sec breath hold, with a breathing rest of 5-6 sec, to obtain the first-pass and delayed arteriovenous phases. For patients with Budd-Chiari syndrome, a third acquisition coinciding with late venous phase was collected to visualize the hepatic veins, which was carried out by one additional acquisition after a 5-6-sec breathing time. This review describes the clinical application of 3D CE MRV in vena cava congenital anomalies, superior and inferior vena cava syndrome, Budd-Chiari syndrome, peripheral vein thrombosis extending to the vena cava, pre-operational evaluation in portosystemic shunting and post-surgical follow-up, and road-mapping for the placement and evaluation of complications of central venous devices.« less

  12. Right Atrial Anomalous Muscle Bundle Presenting with Acute Superior Vena Cava Syndrome and Pulmonary Embolism: Surgical Management.

    PubMed

    Madjarov, Jeko M; Katz, Michael G; Madjarova, Sophia; Madzharov, Svetozar; Arko, Frank R; Miller, David W; Robicsek, Francis

    2018-05-21

    An anomalous muscle bundle crossing the right atrial cavity represents a pathological finding with unproved clinical significance. This congenital anomaly may be difficult to recognize via echocardiography and could be confused with other intra-cavitary lesions. We report a case of a 53-year-old female presented to the cardio-vascular service with acute superior vena cava syndrome and sub-massive pulmonary embolism. The patient underwent venography confirming superior vena cava stenosis. A ventilation/perfusion lung scan showed two sizable perfusion defects due to pulmonary embolism. MRI and echocardiography imaging demonstrated right atrium mass. Surgery was then carried out using standard cardiopulmonary bypass; right atrial muscle bundle was excised and superior vena cava reconstruction was performed. The patient was discharged uneventfully and remains symptom-free at two years follow-up. In cases of nonmalignant pathology of superior vena cava syndrome, appropriate studies should be conducted to exclude potential congenital abnormalities such as this anomalous muscle bundle in the right atrium. Open heart surgery is a viable treatment option in select cases. Published by Elsevier Inc.

  13. Retrograde non trans-septal balloon mitral valvotomy in mitral stenosis with interrupted inferior vena cava, left superior vena cava, and hugely dilated coronary sinus.

    PubMed

    Nath, Ranjit Kumar; Soni, Dheeraj Kumar

    2015-12-01

    A 22-year-old woman with severe mitral stenosis was referred to us for further evaluation and management. She was found to have severe mitral stenosis, severe tricuspid regurgitation with dilated right atrium and right ventricle with persistent left superior vena cava and hugely dilated coronary sinus. Valve was suitable for balloon mitral valvotomy. Cardiac catheterization showed interrupted inferior vena cava with azygos continuation to right atrium and large left superior vena cava draining to coronary sinus which was very much dilated. Right trans-jugular approach was tried for balloon mitral valvotomy, but was unsuccessful due to a very large right atrium and coronary sinus. Retrograde non trans-septal approach was used and balloon valvotomy was done successfully using a 24 mm × 40 mm TYSHAK balloon without any major complication. Reduction in the transmitral pressure gradient on cardiac catheterization data and transthoracic echocardiography confirmed successful procedure. Balloon mitral valvotomy can be done successfully in patients with the above unusual cardiac anatomy with no major procedural complications. © 2015 Wiley Periodicals, Inc.

  14. Iatrogenic Diversion of Inferior Vena Cava into Left Atrium after Surgery for a Rare Combination of Congenital Heart Diseases

    PubMed Central

    Sabzi, Feridoun

    2016-01-01

    Atrial septal defect (ASD) is a common congenital anomaly that has low surgical mortality and morbidity. We report a very rare case of a low-lying ASD, combined with the drainage of the inferior vena cava and the left superior vena cava into the left atrium. This combination was associated with an unroofed coronary sinus. We also describe an iatrogenic surgical diversion of the inferior vena cava into the left atrium with its complication. The patient presented with moderate cyanosis and was referred for elective ASD repair. He underwent surgical repair of the ASD after transthoracic echocardiography. Early postoperative right-to-left shunting with cyanosis and hypoxia was associated with abdominal complications. Surgical re-exploration revealed the diversion of the inferior vena cava into the left atrium, which was repaired with a pericardial patch. Peptic ulcer perforation was repaired after abdominal laparotomy. The patient had an uneventful recovery and was discharged home on the 17th postoperative day. One-year follow-up revealed no recurrence of cyanosis or residual ASD on echocardiography. PMID:27928261

  15. Optimal vitrification protocol for mouse ovarian tissue cryopreservation: effect of cryoprotective agents and in vitro culture on vitrified-warmed ovarian tissue survival.

    PubMed

    Youm, Hye Won; Lee, Jung Ryeol; Lee, Jaewang; Jee, Byung Chul; Suh, Chang Suk; Kim, Seok Hyun

    2014-04-01

    What is the optimal vitrification protocol according to the cryoprotective agent (CPA) for ovarian tissue (OT) cryopreservation? The two-step protocol with 7.5% ethylene glycol (EG) and 7.5% dimethyl sulfoxide (DMSO) for 10 min then 20% EG, 20% DMSO and 0.5 M sucrose for 5 min showed the best results in mouse OT vitrification. Establishing the optimal cryopreservation protocol is one of the most important steps to improve OT survival. However, only a few studies have compared vitrification protocols with different CPAs and investigated the effect of in vitro culture (IVC) on vitrified-warmed OT survival. Some recent papers proposed that a combination of CPAs has less toxicity than one type of CPA. However, the efficacy of different types and concentrations of CPA are not yet well documented. A total of 644 ovaries were collected from 4-week-old BDF1 mice, of which 571 ovaries were randomly assigned to 8 groups and vitrified using different protocols according to CPA composition and the remaining 73 ovaries were used as controls. After warming, each of the eight groups of ovaries was further randomly divided into four subgroups and in vitro cultured for 0, 0.5, 2 and 4 h, respectively. Ovaries of the best two groups among the eight groups were autotransplanted after IVC. The CPA solutions for the eight groups were composed of EDS, ES, ED, EPS, EF, EFS, E and EP, respectively (E, EG; D, DMSO; P, propanediol; S, sucrose; F, Ficoll). The IVC medium was composed of α-minimal essential medium, 10% fetal bovine serum and 10 mIU/ml follicle-stimulating hormone (FSH). Autotransplantation of vitrified-warmed OTs after IVC (0 to 4 h) using the EDS or ES protocol was performed, and the grafts were recovered after 3 weeks. Ovarian follicles were assessed for morphology, apoptosis, proliferation and FSH level. The percentages of the morphologically intact (G1) and apoptotic follicles in each group at 0, 0.5, 2 and 4 h of IVC were compared. For G1 follicles at 0 and 4 h of IVC, the EDS group showed the best results at 63.8 and 46.6%, respectively, whereas the EP group showed the worst results at 42.2 and 12.8%, respectively. The apoptotic follicle ratio was lowest in the EDS group at 0 h (8.1%) and 0.5 h (12.7%) of IVC. All of the eight groups showed significant decreases in G1 follicles and increases in apoptotic follicles as IVC duration progressed. After autotransplantation, the EDS 0 h group showed a significantly higher G1 percentage (84.9%) than did the other groups (42.4-58.8%), while only the ES 4 h group showed a significant decrease in the number of proliferative cells (80.6%, 87.6-92.9%). However, no significant differences in apoptotic rates and FSH levels were observed between the groups after autotransplantation. The limitation of this study was the absence of in vitro fertilization using oocytes obtained from OT grafts, which should be performed to confirm the outcomes of ovarian cryopreservation and transplantation. We compared eight vitrification protocols according to CPA composition and found the EDS protocol to be the optimal method among them. The data presented herein will help improve OT cryopreservation protocols for humans or other animals.

  16. Anomalous dual drainage of the right pulmonary veins in a patient with cor triatriatum: report of a case without scimitar sign.

    PubMed

    Tansel, T; Harmandar, B; Dayioglu, E; Onursal, E

    2006-02-01

    The majority of patients with partial anomalous drainage of pulmonary veins are asymptomatic during infancy and childhood. Patients with significant left-to-right shunt develop symptoms and benefit from early corrective surgery. Anomalous pulmonary veins draining into inferior vena cava is very rare and frequently encountered in association with scimitar syndrome. The purpose of this case report is to describe a non-scimitar patient with cor triatriatum who had anomalous dual drainage of right pulmonary veins into inferior vena cava/left atrium and anomalous connection of persistent left superior vena cava with a common pulmonary venous chamber. The patient underwent an operation with redirection of anomalous pulmonary venous drainage into left atrium and ligation of persistent left superior vena cava.

  17. Complete Circular Genome Sequence of Successful ST8/SCCmecIV Community-Associated Methicillin-Resistant Staphylococcus aureus (OC8) in Russia: One-Megabase Genomic Inversion, IS256’s Spread, and Evolution of Russia ST8-IV

    PubMed Central

    Wan, Tsai-Wen; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V.; Singur, Olga A.; Gostev, Vladimir V.; Sidorenko, Sergey V.; Peryanova, Olga V.; Salmina, Alla B.; Reva, Galina V.; Teng, Lee-Jene; Yamamoto, Tatsuo

    2016-01-01

    ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256’s strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages. PMID:27741255

  18. A single center experience with retrievable IVC filters.

    PubMed

    Renno, Anas; Khateeb, Faisal; Kazan, Viviane; Qu, Weikai; Gollapudi, Anurekha; Aplin, Brett; Abbas, Jihad; Zelenock, Gerald; Nazzal, Munier

    2015-08-01

    To evaluate retrievable IVC filters in our institution and assess their retrieval following a well-structured follow up program. Retrospective cohort study. The medical records of patients implanted with retrievable IVC filters were reviewed. All retrievable filter insertions between July 2007 and August 2011 at our institution were reviewed. Data was analyzed for age, gender, indication, complications, retrieval rate, and brand of filter inserted. Statistical analysis was done using SPSS software v19. Chi-square was used to compare discrete data and t-test for continuous data. P < 0.05 was significant. A total of 484 patients were reviewed of which 258 (53.1%) had a complete medical record. And 96 (37.2%) filters were placed as permanent at the time of insertion. An additional 40 (15.5%) filters were converted to permanent (total permanent filters 136; 52.7%). Death was reported in 26 (10%) patients and 96 (37.2%) out of the remaining 232 patients presented for potential retrieval. Also, 73 (28.2%) had an attempt to retrieve the filters, 69 (94.5%) were successful and 4 (5.4%) failed to retrieve. The remaining 23 (8.9%) patients declined retrieval. Filters studied include Celect (38%), Bard (31.4%), Option (26.2%), Tulip (4.1%), and Recovery (0.2%). Bard was more commonly used as a retrievable filter (80.9%). Retrieval on the first attempt was 90.4% (n = 66) successful. Of the remaining seven filters, three were successfully retrieved on a second attempt, and four failed to retrieve due to filter tilt. The success rates of retrieval for Celect and Tulip were significantly lower than for Bard (p = 0.04 and 0.023, respectively). Our study showed that a variety of IVC filters can be retrieved successfully with minimal complication rates. In more than half of our patients, IVC filters were used as permanent. Failure of retrieval was most frequently due to filter tilting. © The Author(s) 2014.

  19. Complete Circular Genome Sequence of Successful ST8/SCCmecIV Community-Associated Methicillin-Resistant Staphylococcus aureus (OC8) in Russia: One-Megabase Genomic Inversion, IS256's Spread, and Evolution of Russia ST8-IV.

    PubMed

    Wan, Tsai-Wen; Khokhlova, Olga E; Iwao, Yasuhisa; Higuchi, Wataru; Hung, Wei-Chun; Reva, Ivan V; Singur, Olga A; Gostev, Vladimir V; Sidorenko, Sergey V; Peryanova, Olga V; Salmina, Alla B; Reva, Galina V; Teng, Lee-Jene; Yamamoto, Tatsuo

    2016-01-01

    ST8/SCCmecIV community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) has been a common threat, with large USA300 epidemics in the United States. The global geographical structure of ST8/SCCmecIV has not yet been fully elucidated. We herein determined the complete circular genome sequence of ST8/SCCmecIVc strain OC8 from Siberian Russia. We found that 36.0% of the genome was inverted relative to USA300. Two IS256, oppositely oriented, at IS256-enriched hot spots were implicated with the one-megabase genomic inversion (MbIN) and vSaβ split. The behavior of IS256 was flexible: its insertion site (att) sequences on the genome and junction sequences of extrachromosomal circular DNA were all divergent, albeit with fixed sizes. A similar multi-IS256 system was detected, even in prevalent ST239 healthcare-associated MRSA in Russia, suggesting IS256's strong transmission potential and advantage in evolution. Regarding epidemiology, all ST8/SCCmecIVc strains from European, Siberian, and Far Eastern Russia, examined had MbIN, and geographical expansion accompanied divergent spa types and resistance to fluoroquinolones, chloramphenicol, and often rifampicin. Russia ST8/SCCmecIVc has been associated with life-threatening infections such as pneumonia and sepsis in both community and hospital settings. Regarding virulence, the OC8 genome carried a series of toxin and immune evasion genes, a truncated giant surface protein gene, and IS256 insertion adjacent to a pan-regulatory gene. These results suggest that unique single ST8/spa1(t008)/SCCmecIVc CA-MRSA (clade, Russia ST8-IVc) emerged in Russia, and this was followed by large geographical expansion, with MbIN as an epidemiological marker, and fluoroquinolone resistance, multiple virulence factors, and possibly a multi-IS256 system as selective advantages.

  20. Mediastinal fibrosis and superior vena cava syndrome.

    PubMed

    Novella Sánchez, Laura; Sanz Herrero, Francisco; Berraondo Fraile, Javier; Fernández Fabrellas, Estrella

    2013-08-01

    Superior vena cava syndrome is a clear sign for clinicians of infiltrative mediastinal involvement, usually caused by neoplasms in this location, and it is an indicator of poor prognosis. However, other diseases of benign origin can also cause these alterations. We present the case of a 34-year-old patient who debuted with symptoms of superior vena cava syndrome due to idiopathic mediastinal fibrosis, which presented a torpid evolution and few therapeutic alternatives. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.

Top