Determining and Controlling the Magnesium Composition in CdTe/CdMgTe Heterostructures
LeBlanc, E. G.; Edirisooriya, M.; Ogedengbe, O. S.; ...
2017-06-05
The relationships between Mg composition, band gap, and lattice characteristics are investigated for Cd 1-xMg xTe barrier layers using a combination of cathodoluminescence, energy dispersive x-ray spectroscopy, variable angle spectral ellipsometry, and atom probe tomography. The use of a simplified, yet accurate, variable angle spectral ellipsometry analysis is shown to be appropriate for fast determination of composition in thin Cd 1-xMg xTe layers. The validity of using high-resolution x-ray diffraction for CdTe/Cd 1-xMg xTe double heterostructures is discussed. Furthermore, the stability of CdTe/Cd 1-xMg xTe heterostructures are investigated with respect to thermal processing.
Determining and Controlling the Magnesium Composition in CdTe/CdMgTe Heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
LeBlanc, E. G.; Edirisooriya, M.; Ogedengbe, O. S.
The relationships between Mg composition, band gap, and lattice characteristics are investigated for Cd 1-xMg xTe barrier layers using a combination of cathodoluminescence, energy dispersive x-ray spectroscopy, variable angle spectral ellipsometry, and atom probe tomography. The use of a simplified, yet accurate, variable angle spectral ellipsometry analysis is shown to be appropriate for fast determination of composition in thin Cd 1-xMg xTe layers. The validity of using high-resolution x-ray diffraction for CdTe/Cd 1-xMg xTe double heterostructures is discussed. Furthermore, the stability of CdTe/Cd 1-xMg xTe heterostructures are investigated with respect to thermal processing.
Assessing Cd-induced stress from plant spectral response
NASA Astrophysics Data System (ADS)
Kancheva, Rumiana; Georgiev, Georgi
2014-10-01
Remote sensing plays a significant role in local, regional and global monitoring of land covers. Ecological concerns worldwide determine the importance of remote sensing applications for the assessment of soil conditions, vegetation health and identification of stress-induced changes. The extensive industrial growth and intensive agricultural land-use arise the serious ecological problem of environmental pollution associated with the increasing anthropogenic pressure on the environment. Soil contamination is a reason for degradation processes and temporary or permanent decrease of the productive capacity of land. Heavy metals are among the most dangerous pollutants because of their toxicity, persistent nature, easy up-take by plants and long biological half-life. This paper takes as its focus the study of crop species spectral response to Cd pollution. Ground-based experiments were performed, using alfalfa, spring barley and pea grown in Cd contaminated soils and in different hydroponic systems under varying concentrations of the heavy metal. Cd toxicity manifested itself by inhibition of plant growth and synthesis of photosynthetic pigments. Multispectral reflectance, absorbance and transmittance, as well as red and far red fluorescence were measured and examined for their suitability to detect differences in plant condition. Statistical analysis was performed and empirical relationships were established between Cd concentration, plant growth variables and spectral response Various spectral properties proved to be indicators of plant performance and quantitative estimators of the degree of the Cd-induced stress.
NASA Astrophysics Data System (ADS)
Magaryan, K. A.; Eremchev, I. Y.; Karimullin, K. R.; Knyazev, M. V.; Mikhailov, M. A.; Vasilieva, I. A.; Klimusheva, G. V.
2015-09-01
Luminescence spectra of the colloidal solution of CdSe quantum dots (in toluene) were studied in a wide range of low temperatures. Samples were synthesized in the liquid crystal matrix of cadmium octanoate (CdC8). A comparative analysis of the obtained data with previous results was performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drabo, Mebougna L.; Egarievwe, Stephen U.; Okwechime, Ifechukwude O.
Surface defects caused during cutting and polishing in the fabrication of cadmium zinc telluride (CdZnTe) nuclear detectors limit their spectral performance. Chemical treatments are often used to remove surface damages and defects. In this paper, we present the analysis of Te and TeO 2 species on the surfaces of CdZnTe nuclear detectors treated with hydrogen bromide and ammonium-based solutions. The CdZnTe wafers were chemo-mechanically polished in a mixture of hydrogen bromide in hydrogen peroxide and ethylene glycol, followed by a chemical passivation in a mixture of ammonium fluoride and hydrogen peroxide solution. X-ray photoelectron spectroscopy showed significant conversion of Temore » to TeO 2, thus producing a more chemically stable surface. The resistivity of the CdZnTe samples is in the order of 1010 ohms-cm. The current for a given applied voltage increased following the passivation and decreased after a 3-hour period. Results from spectral response measurements showed that the 59.5-keV gamma-peak of Am-241 was stable under the same channel for the surface treatment processes.« less
Drabo, Mebougna L.; Egarievwe, Stephen U.; Okwechime, Ifechukwude O.; ...
2017-04-30
Surface defects caused during cutting and polishing in the fabrication of cadmium zinc telluride (CdZnTe) nuclear detectors limit their spectral performance. Chemical treatments are often used to remove surface damages and defects. In this paper, we present the analysis of Te and TeO 2 species on the surfaces of CdZnTe nuclear detectors treated with hydrogen bromide and ammonium-based solutions. The CdZnTe wafers were chemo-mechanically polished in a mixture of hydrogen bromide in hydrogen peroxide and ethylene glycol, followed by a chemical passivation in a mixture of ammonium fluoride and hydrogen peroxide solution. X-ray photoelectron spectroscopy showed significant conversion of Temore » to TeO 2, thus producing a more chemically stable surface. The resistivity of the CdZnTe samples is in the order of 1010 ohms-cm. The current for a given applied voltage increased following the passivation and decreased after a 3-hour period. Results from spectral response measurements showed that the 59.5-keV gamma-peak of Am-241 was stable under the same channel for the surface treatment processes.« less
NASA Astrophysics Data System (ADS)
Li, Qingli; Peng, Hui; Wang, Jing; Wang, Yiting; Guo, Fangmin
2015-11-01
A direct spatial and spectral observation of CdSe and CdSe/CdS quantum dots (QDs) as probes in live cells is performed by using a custom molecular hyperspectral imaging (MHI) system. Water-soluble CdSe and CdSe/CdS QDs are synthesized in aqueous solution under the assistance of high-intensity ultrasonic irradiation and incubated with colon cancer cells for bioimaging. Unlike the traditional fluorescence microscopy methods, MHI technology can identify QD probes according to their spectral signatures and generate coexpression and stain titer maps by a clustering method. The experimental results show that the MHI method has potential to unmix biomarkers by their spectral information, which opens up a pathway of optical multiplexing with many different QD probes.
Chen, Tao; Chang, Qingrui; Clevers, J G P W; Kooistra, L
2015-11-01
Soil heavy metal pollution due to long-term sewage irrigation is a serious environmental problem in many irrigation areas in northern China. Quickly identifying its pollution status is an important basis for remediation. Visible-near-infrared reflectance spectroscopy (VNIRS) provides a useful tool. In a case study, 76 soil samples were collected and their reflectance spectra were used to estimate cadmium (Cd) concentration by partial least squares regression (PLSR) and back propagation neural network (BPNN). To reduce noise, six pre-treatments were compared, in which orthogonal signal correction (OSC) was first used in soil Cd estimation. Spectral analysis and geostatistics were combined to identify Cd pollution hotspots. Results showed that Cd was accumulated in topsoil at the study area. OSC can effectively remove irrelevant information to improve prediction accuracy. More accurate estimation was achieved by applying a BPNN. Soil Cd pollution hotspots could be identified by interpolating the predicted values obtained from spectral estimates. Copyright © 2015 Elsevier Ltd. All rights reserved.
Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX
NASA Astrophysics Data System (ADS)
Rajendran, K.; Walsh, M. F.; de Ruiter, N. J. A.; Chernoglazov, A. I.; Panta, R. K.; Butler, A. P. H.; Butler, P. H.; Bell, S. T.; Anderson, N. G.; Woodfield, T. B. F.; Tredinnick, S. J.; Healy, J. L.; Bateman, C. J.; Aamir, R.; Doesburg, R. M. N.; Renaud, P. F.; Gieseg, S. P.; Smithies, D. J.; Mohr, J. L.; Mandalika, V. B. H.; Opie, A. M. T.; Cook, N. J.; Ronaldson, J. P.; Nik, S. J.; Atharifard, A.; Clyne, M.; Bones, P. J.; Bartneck, C.; Grasset, R.; Schleich, N.; Billinghurst, M.
2014-03-01
This paper discusses methods for reducing beam hardening effects and metal artefacts using spectral x-ray information in biomaterial samples. A small-animal spectral scanner was operated in the 15 to 80 keV x-ray energy range for this study. We use the photon-processing features of a CdTe-Medipix3RX ASIC in charge summing mode to reduce beam hardening and associated artefacts. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. The cupping effect and streak artefacts are quantified in the spectral datasets. The results show reduction in beam hardening effects and metal artefacts in the narrow high energy range acquired using the spectroscopic detector. A post-reconstruction comparison between CdTe-Medipix3RX and Si-Medipix3.1 is discussed. The raw data and processed data are made available (http://hdl.handle.net/10092/8851) for testing with other software routines.
An x ray archive on your desk: The Einstein CD-ROM's
NASA Technical Reports Server (NTRS)
Prestwich, A.; Mcdowell, J.; Plummer, D.; Manning, K.; Garcia, M.
1992-01-01
Data from the Einstein Observatory imaging proportional counter (IPC) and high resolution imager (HRI) were released on several CD-ROM sets. The sets released so far include pointed IPC and HRI observations in both simple image and detailed photon event list format, as well as the IPC slew survey. With the data on these CD-ROMS's the user can perform spatial analysis (e.g., surface brightness distributions), spectral analysis (with the IPC event lists), and timing analysis (with the IPC and HRI event lists). The next CD-ROM set will contain IPC unscreened data, allowing the user to perform custom screening to recover, for instance, data during times of lost aspect data or high particle background rates.
QEEG and LORETA in Teenagers With Conduct Disorder and Psychopathic Traits.
Calzada-Reyes, Ana; Alvarez-Amador, Alfredo; Galán-García, Lídice; Valdés-Sosa, Mitchell
2017-05-01
Few studies have investigated the impact of the psychopathic traits on the EEG of teenagers with conduct disorder (CD). To date, there is no other research studying low-resolution brain electromagnetic tomography (LORETA) technique using quantitative EEG (QEEG) analysis in adolescents with CD and psychopathic traits. To find electrophysiological differences specifically related to the psychopathic traits. The current investigation compares the QEEG and the current source density measures between adolescents with CD and psychopathic traits and adolescents with CD without psychopathic traits. The resting EEG activity and LORETA for the EEG fast spectral bands were evaluated in 42 teenagers with CD, 25 with and 17 without psychopathic traits according to the Antisocial Process Screening Device. All adolescents were assessed using the DSM-IV-TR criteria. The EEG visual inspection characteristics and the use of frequency domain quantitative analysis techniques (narrow band spectral parameters) are described. QEEG analysis showed a pattern of beta activity excess on the bilateral frontal-temporal regions and decreases of alpha band power on the left central-temporal and right frontal-central-temporal regions in the psychopathic traits group. Current source density calculated at 17.18 Hz showed an increase within fronto-temporo-striatal regions in the psychopathic relative to the nonpsychopathic traits group. These findings indicate that QEEG analysis and techniques of source localization may reveal differences in brain electrical activity among teenagers with CD and psychopathic traits, which was not obvious to visual inspection. Taken together, these results suggest that abnormalities in a fronto-temporo-striatal network play a relevant role in the neurobiological basis of psychopathic behavior.
Khani, Rouhollah; Ghasemi, Jahan B; Shemirani, Farzaneh
2014-10-01
This research reports the first application of β-cyclodextrin (β-CD) complexes as a new method for generation of three way data, combined with second-order calibration methods for quantification of a binary mixture of caffeic (CA) and vanillic (VA) acids, as model compounds in fruit juices samples. At first, the basic experimental parameters affecting the formation of inclusion complexes between target analytes and β-CD were investigated and optimized. Then under the optimum conditions, parallel factor analysis (PARAFAC) and bilinear least squares/residual bilinearization (BLLS/RBL) were applied for deconvolution of trilinear data to get spectral and concentration profiles of CA and VA as a function of β-CD concentrations. Due to severe concentration profile overlapping between CA and VA in β-CD concentration dimension, PARAFAC could not be successfully applied to the studied samples. So, BLLS/RBL performed better than PARAFAC. The resolution of the model compounds was possible due to differences in the spectral absorbance changes of the β-CD complexes signals of the investigated analytes, opening a new approach for second-order data generation. The proposed method was validated by comparison with a reference method based on high-performance liquid chromatography photodiode array detection (HPLC-PDA), and no significant differences were found between the reference values and the ones obtained with the proposed method. Such a chemometrics-based protocol may be a very promising tool for more analytical applications in real samples monitoring, due to its advantages of simplicity, rapidity, accuracy, sufficient spectral resolution and concentration prediction even in the presence of unknown interferents. Copyright © 2014 Elsevier B.V. All rights reserved.
Synthesis and Structural Characterization of CdFe2O4 Nanostructures
NASA Astrophysics Data System (ADS)
Kalpanadevi, K.; Sinduja, C. R.; Manimekalai, R.
The synthesis of CdFe2O4 nanoparticles has been achieved by a simple thermal decomposition method from the inorganic precursor, [CdFe2(cin)3(N2H4)3], which was obtained by a simple precipitation method from the corresponding metal salts, cinnamic acid and hydrazine hydrate. The precursor was characterized by hydrazine and metal analyses, infrared spectral analysis and thermo gravimetric analysis. On appropriate annealing, [CdFe2(cin)3(N2H4)3] yielded CdFe2O4 nanoparticles. The XRD studies showed that the crystallite size of the particles was 13nm. The results of HRTEM studies also agreed well with those of XRD. SAED pattern of the sample established the polycrystalline nature of the nanoparticles. SEM images displayed a random distribution of grains in the sample.
Gu, Junsi; Fahrenkrug, Eli; Maldonado, Stephen
2014-09-02
The substrate-overlayer approach has been used to acquire surface enhanced Raman spectra (SERS) during and after electrochemical atomic layer deposition (ECALD) of CdSe, CdTe, and CdS thin films. The collected data suggest that SERS measurements performed with off-resonance (i.e. far from the surface plasmonic wavelength of the underlying SERS substrate) laser excitation do not introduce perturbations to the ECALD processes. Spectra acquired in this way afford rapid insight on the quality of the semiconductor film during the course of an ECALD process. For example, SERS data are used to highlight ECALD conditions that yield crystalline CdSe and CdS films. In contrast, SERS measurements with short wavelength laser excitation show evidence of photoelectrochemical effects that were not germane to the intended ECALD process. Using the semiconductor films prepared by ECALD, the substrate-overlayer SERS approach also affords analysis of semiconductor surface adsorbates. Specifically, Raman spectra of benzenethiol adsorbed onto CdSe, CdTe, and CdS films are detailed. Spectral shifts in the vibronic features of adsorbate bonding suggest subtle differences in substrate-adsorbate interactions, highlighting the sensitivity of this methodology.
NASA Astrophysics Data System (ADS)
Lee, Young Ju; Ahn, Hyung Joon; Lee, Gi-Ja; Jung, Gyeong Bok; Lee, Gihyun; Kim, Dohyun; Shin, Jae-Ho; Jin, Kyung-Hyun; Park, Hun-Kuk
2015-07-01
The study was to investigate the changes in biochemical properties of activated mature CD8+ T cells related to apoptosis at a molecular level. We confirmed the activation and apoptosis of CD8+ T cells by fluorescence-activated cell sorting and atomic force microscopy and then performed Raman spectral measurements on activated mature CD8+ T cells and cellular deoxyribose nucleic acid (DNA). In the activated mature CD8+ T cells, there were increases in protein spectra at 1002 and 1234 cm-1. In particular, to assess the apoptosis-related DNA spectral signatures, we investigated the spectra of the cellular DNA isolated from resting and activated mature CD8+ T cells. Raman spectra at 765 to 786 cm-1 and 1053 to 1087 cm-1 were decreased in activated mature DNA. In addition, we analyzed Raman spectrum using the multivariate statistical method including principal component analysis. Raman spectra of activated mature DNA are especially well-discriminated from those of resting DNA. Our findings regarding the biochemical and structural changes associated with apoptosis in activated mature T cells and cellular DNA according to Raman spectroscopy provide important insights into allospecific immune responses generated after organ transplantation, and may be useful for therapeutic manipulation of the immune response.
Saliency-Guided Change Detection of Remotely Sensed Images Using Random Forest
NASA Astrophysics Data System (ADS)
Feng, W.; Sui, H.; Chen, X.
2018-04-01
Studies based on object-based image analysis (OBIA) representing the paradigm shift in change detection (CD) have achieved remarkable progress in the last decade. Their aim has been developing more intelligent interpretation analysis methods in the future. The prediction effect and performance stability of random forest (RF), as a new kind of machine learning algorithm, are better than many single predictors and integrated forecasting method. In this paper, we present a novel CD approach for high-resolution remote sensing images, which incorporates visual saliency and RF. First, highly homogeneous and compact image super-pixels are generated using super-pixel segmentation, and the optimal segmentation result is obtained through image superimposition and principal component analysis (PCA). Second, saliency detection is used to guide the search of interest regions in the initial difference image obtained via the improved robust change vector analysis (RCVA) algorithm. The salient regions within the difference image that correspond to the binarized saliency map are extracted, and the regions are subject to the fuzzy c-means (FCM) clustering to obtain the pixel-level pre-classification result, which can be used as a prerequisite for superpixel-based analysis. Third, on the basis of the optimal segmentation and pixel-level pre-classification results, different super-pixel change possibilities are calculated. Furthermore, the changed and unchanged super-pixels that serve as the training samples are automatically selected. The spectral features and Gabor features of each super-pixel are extracted. Finally, superpixel-based CD is implemented by applying RF based on these samples. Experimental results on Ziyuan 3 (ZY3) multi-spectral images show that the proposed method outperforms the compared methods in the accuracy of CD, and also confirm the feasibility and effectiveness of the proposed approach.
NASA Technical Reports Server (NTRS)
Boeer, K. W.
1971-01-01
Theoretical and experimental investigations on CdS single crystals and CuxS:CdS photovoltaic cells prepared from CdS single crystals by a chemical-dip procedure are described. The studies are aimed at clarifying cell mechanisms which affect key cell properties (efficiency, reliability, and lifetime) by examining the properties of intrinsic and extrinsic defects in the junction and surface regions and their effects on carrier transport through these regions. The experimental research described includes studies of thermal, infrared, and field quenching of acceptor-doped CdS crystals; investigation of optical and electrical properties of CuxS:CdS photovoltaic cells (current-voltage characteristics, spectral distribution of photocurrent and photovoltage) and the dependence of these properties on temperature and light intensity; measurement of changes, as a result of heat treatment in ultrahigh vacuum, in the spectral distribution of photoconductivity at room temperature and liquid nitrogen temperature, the luminescence spectrum at liquid nitrogen temperature, and the thermally stimulated current curves of CdS crystals; determination of the effect of irradiation with 150 keV (maximum) X-rays on the spectral distribution of photoconductivity and thermally-stimulated current of CdS crystals; and studies of the effect of growth conditions on the photoconductive properties of CdS crystals.
Group IIB-VIA semiconductor oxide cluster ions
NASA Astrophysics Data System (ADS)
Jayasekharan, Thankan
2018-05-01
Metal oxide cluster ions, MnOm± (M = Zn, Cd) and HgnOm- of various stoichiometry have been generated from solid IIB-VIA semiconductor oxides targets, (ZnO(s), CdO(s), and HgO(s)) by using pulse laser desorption ionization time of flight mass spectrometry with a laser of λ = 355 nm. Analysis of mass spectral data indicates the formation of stoichiometric cluster ions viz., (ZnO)n=1-30+ and (CdO)n=1-40+ along with -O bound anions, (ZnO)n=1-30O-, (CdO)n=1-40O- and (HgO)n=1-36O- from their respective solids. Further, metal oxoanions such as ZnOn=2,3-, CdOn=2,3,6-, and HgOn=2,3,6,7- have also been noted signifying the higher coordination ability of both Cd and Hg with O/O2/O3 species.
NASA Astrophysics Data System (ADS)
Motrich, A. V.; Ushenko, O. G.
2018-01-01
The results of statistical dependence and correlation structures of two-dimensional Mueller matrix elements in various spectral regions of laser radiation by changes in the distribution of orientations of optical axes and birefringence of protein crystals. Namely, a two-wave ("red-blue") approach - layer of biological tissues irradiated by He-Ne laser (λ1 = 0,63μm ) and He-Cd laser (λ1 = 0,41μm )was used Conducted analysis of polarimetric sensitivity was made, a state of polarization points that contain volumetric structures of biological objects to spectral region of laser radiation was detected.
NASA Astrophysics Data System (ADS)
Fujimoto, Kazuhiro J.; Balashov, Sergei P.
2017-03-01
The role of vibronic coupling of antenna carotenoid and retinal in xanthorhodopsin (XR) in its circular dichroism (CD) spectrum is examined computationally. A vibronic exciton model combined with a transition-density-fragment interaction (TDFI) method is developed, and applied to absorption and CD spectral calculations of XR. The TDFI method is based on the electronic Coulomb and exchange interactions between transition densities for individual chromophores [K. J. Fujimoto, J. Chem. Phys. 137, 034101 (2012)], which provides a quantitative description of electronic coupling energy. The TDFI calculation reveals a dominant contribution of the Coulomb interaction to the electronic coupling energy and a negligible contribution of the exchange interaction, indicating that the antenna function of carotenoid results from the Förster type of excitation-energy transfer, not from the Dexter one. The calculated absorption and CD spectra successfully reproduce the main features of the experimental results, which allow us to investigate the mechanism of biphasic CD spectrum observed in XR. The results indicate that vibronic coupling between carotenoid and retinal plays a significant role in the shape of the CD spectrum. Further analysis reveals that the negative value of electronic coupling directly contributes to the biphasic shape of CD spectrum. This study also reveals that the C6—C7 bond rotation of salinixanthin is not the main factor for the biphasic CD spectrum although it gives a non-negligible contribution to the spectral shift. The present method is useful for analyzing the molecular mechanisms underlying the chromophore-chromophore interactions in biological systems.
Hydrothermal assisted growth of CdSe nanoparticles and study on its dielectric properties
NASA Astrophysics Data System (ADS)
Jamble, Shweta N.; Ghoderao, Karuna P.; Kale, Rohidas B.
2017-11-01
In this work, we have synthesized cadmium selenide (CdSe) nanoparticles by using cadmium chloride (CdCl2) as cadmium ion and sodium selenosulfate (Na2SeSO3) as selenium ion sources through a simple, convenient and cost-effective hydrothermal route at 180 °C temperature for 24 h. Aqueous ammonia was employed as a complex reagent to adjust the pH of the solution. Structural analysis of the obtained product was carried out by using x-ray diffractometer, which revealed that the final product has a cubic structure of CdSe with average crystallite size 13.15 nm. The cauliflower-like CdSe nanostructures were confirmed from the scanning electron microscopy and high-resolution transmission electron microscopy. EDS analysis indicates that the obtained product has a good elemental stoichiometric ratio. The electron diffraction pattern reveals the polycrystalline nature of CdSe. From UV-visible absorption spectral analysis, the optical energy bandgap of CdSe nanoparticles was found to be 1.90 eV. XPS spectra presented Cd 3d3/2, Cd 3d5/2 and Se 3d3/2 peaks at 411.04, 404.29 and 53.52 eV respectively. The CdSe nanoparticles exhibit photoluminescence with two distinct emission bands at 632 nm and 720 nm. FTIR study was used towards the understanding of the formation mechanism and bonding on the surface of the resulting nanoparticles. The dielectric properties of a pelletized sample of CdSe nanoparticles were carried out at room temperature.
Flow Cytometry Data Preparation Guidelines for Improved Automated Phenotypic Analysis.
Jimenez-Carretero, Daniel; Ligos, José M; Martínez-López, María; Sancho, David; Montoya, María C
2018-05-15
Advances in flow cytometry (FCM) increasingly demand adoption of computational analysis tools to tackle the ever-growing data dimensionality. In this study, we tested different data input modes to evaluate how cytometry acquisition configuration and data compensation procedures affect the performance of unsupervised phenotyping tools. An analysis workflow was set up and tested for the detection of changes in reference bead subsets and in a rare subpopulation of murine lymph node CD103 + dendritic cells acquired by conventional or spectral cytometry. Raw spectral data or pseudospectral data acquired with the full set of available detectors by conventional cytometry consistently outperformed datasets acquired and compensated according to FCM standards. Our results thus challenge the paradigm of one-fluorochrome/one-parameter acquisition in FCM for unsupervised cluster-based analysis. Instead, we propose to configure instrument acquisition to use all available fluorescence detectors and to avoid integration and compensation procedures, thereby using raw spectral or pseudospectral data for improved automated phenotypic analysis. Copyright © 2018 by The American Association of Immunologists, Inc.
NASA Astrophysics Data System (ADS)
Sathiyaraj, Ethiraj; Padmavathy, Krishnaraj; Kumar, Chandran Udhaya; Krishnan, Kannan Gokula; Ramalingan, Chennan
2017-11-01
Bis(N-cyclopropyl-N-4-chlorobenzyldithiocarbamato-S,S‧)cadmium(II) (1) and (2,2‧-bipyridine) bis(N-cyclopropyl-N-4-chlorobenzyldithiocarbamato-S,S‧)cadmium(II) (2) have been synthesized and characterized by FT-IR, 1HNMR and 13C NMR analyses. For the complex 2, single crystal X-ray diffraction analysis and computational studies (optimized geometry, HOMO-LUMO and MEP) have been executed employing DFT/B3LYP method with LANL 2DZ basic set. The optimized bond lengths and bond angles agree well with the experimental results. The complexes 1 and 2 have been used as single source precursors for the synthesis of ethyleneglycol capped CdS1 and CdS2 nanoparticles, respectively. CdS1 and CdS2 nanoparticles have been synthesized by solvothermal method. PXRD, SEM, Elemental colour mapping, EDAX, TEM and UV-Vis spectroscopy have been used to characterize the as-prepared CdS nanoparticles. The X-ray diffraction pattern confirms both their hexagonal structures.
Numerical Device Modeling, Analysis, and Optimization of Extended-SWIR HgCdTe Infrared Detectors
NASA Astrophysics Data System (ADS)
Schuster, J.; DeWames, R. E.; DeCuir, E. A.; Bellotti, E.; Dhar, N.; Wijewarnasuriya, P. S.
2016-09-01
Imaging in the extended short-wavelength infrared (eSWIR) spectral band (1.7-3.0 μm) for astronomy applications is an area of significant interest. However, these applications require infrared detectors with extremely low dark current (less than 0.01 electrons per pixel per second for certain applications). In these detectors, sources of dark current that may limit the overall system performance are fundamental and/or defect-related mechanisms. Non-optimized growth/device processing may present material point defects within the HgCdTe bandgap leading to Shockley-Read-Hall dominated dark current. While realizing contributions to the dark current from only fundamental mechanisms should be the goal for attaining optimal device performance, it may not be readily feasible with current technology and/or resources. In this regard, the U.S. Army Research Laboratory performed physics-based, two- and three-dimensional numerical modeling of HgCdTe photovoltaic infrared detectors designed for operation in the eSWIR spectral band. The underlying impetus for this capability and study originates with a desire to reach fundamental performance limits via intelligent device design.
Characterization of a digital camera as an absolute tristimulus colorimeter
NASA Astrophysics Data System (ADS)
Martinez-Verdu, Francisco; Pujol, Jaume; Vilaseca, Meritxell; Capilla, Pascual
2003-01-01
An algorithm is proposed for the spectral and colorimetric characterization of digital still cameras (DSC) which allows to use them as tele-colorimeters with CIE-XYZ color output, in cd/m2. The spectral characterization consists of the calculation of the color-matching functions from the previously measured spectral sensitivities. The colorimetric characterization consists of transforming the RGB digital data into absolute tristimulus values CIE-XYZ (in cd/m2) under variable and unknown spectroradiometric conditions. Thus, at the first stage, a gray balance has been applied over the RGB digital data to convert them into RGB relative colorimetric values. At a second stage, an algorithm of luminance adaptation vs. lens aperture has been inserted in the basic colorimetric profile. Capturing the ColorChecker chart under different light sources, the DSC color analysis accuracy indexes, both in a raw state and with the corrections from a linear model of color correction, have been evaluated using the Pointer'86 color reproduction index with the unrelated Hunt'91 color appearance model. The results indicate that our digital image capture device, in raw performance, lightens and desaturates the colors.
Direct solar energy conversion for large scale terrestrial use
NASA Technical Reports Server (NTRS)
Boeer, K. W.; Meakin, J. D.
1975-01-01
Various techniques to increase the open circuit voltage are being explored. It had been previously observed that cells made on CdS deposited from a single source gave a consistently higher V sub oc. Further tests have now shown that this effect may in fact relate to differences in source and substrate temperatures. The resulting differences in CdS structure and crystallinity are being documented. Deposits of mixed CdS and ZnS are being produced and will be initially made into cells using the conventional barriering technique. Analysis of I-V characteristics at temperatures between 25 and 110 C is being perfected to provide nondestructive analysis of the Cu2S. Changes due to vacuum heat treatments and exposure to oxygen are also being monitored by the same technique. Detailed spectral response measurements are being made.
Development of a (Hg, Cd)Te photodiode detector, Phase 2. [for 10.6 micron spectral region
NASA Technical Reports Server (NTRS)
1972-01-01
High speed sensitive (Hg,Cd)Te photodiode detectors operating in the 77 to 90 K temperature range have been developed for the 10.6 micron spectral region. P-N junctions formed by impurity (gold) diffusion in p-type (Hg, Cd) Te have been investigated. It is shown that the bandwidth and quantum efficiency of a diode are a constant for a fixed ratio of mobility/lifetime ratio of minority carriers. The minority carrier mobility and lifetime uniquely determine the bandwidth and quantum efficiency and indicate the shallow n on p (Hg,Cd) Te diodes are preferable as high performance, high frequency devices.
Characterization of CdTe and (CdZn)Te detectors with different metal contacts
NASA Astrophysics Data System (ADS)
Pekárek, J.; Belas, E.; Grill, R.; Uxa, Å.; James, R. B.
2013-09-01
In the present work we studied an influence of different types of surface etching and surface passivation of high resistivity CdZnTe-based semiconductor detector material. The aim was to find the optimal conditions to improve the properties of metal-semiconductor contact. The main effort was to reduce the leakage current and thus get better X-ray and gamma-ray spectrum, i.e. to create a detector operating at room temperature based on this semiconductor material with sufficient energy resolution and the maximum charge collection efficiency. Individual surface treatments were characterized by I-V characteristics, spectral analysis and by determination of the profile of the internal electric field.
NASA Astrophysics Data System (ADS)
Rajendiran, N.; Mohandoss, T.; Sankaranarayanan, R. K.
2015-02-01
Inclusion complexation behavior of procainamide (PCA) with two cyclodextrins (α-CD and β-CD) were analyzed by absorption, fluorescence, scanning electron microscope (SEM), transmission electron microscope (TEM), Raman image, FT-IR, differential scanning colorimeter (DSC), Powder X ray diffraction (XRD) and 1H NMR. Blue shift was observed in β-CD whereas no significant spectral shift observed in α-CD. The inclusion complex formation results suggest that water molecules also present in the inside of the CD cavity. The present study revealed that the phenyl ring of the PCA drug is entrapped in the CD cavity. Cyclodextrin studies show that PCA forms 1:2 inclusion complex with α-CD and β-CD. PCA:α-CD complex form nano-sized particles (46 nm) and PCA:β-CD complex form self-assembled to micro-sized tubular structures. The shape-shifting of 2D nanosheets into 1D microtubes by simple rolling mechanism were analysed by micro-Raman and TEM images. Thermodynamic parameters (ΔH, ΔG and ΔS) of inclusion process were determined from semiempirical PM3 calculations.
Murphy, Karen E; Vetter, Thomas W
2013-05-01
The potential effect of spectral interference on the accurate measurement of the cadmium (Cd) mass fraction in fortified breakfast cereal and a variety of dietary supplement materials using inductively coupled plasma quadrupole mass spectrometry was studied. The materials were two new standard reference materials (SRMs)--SRM 3233 Fortified Breakfast Cereal and SRM 3532 Calcium Dietary Supplement--as well as several existing materials--SRM 3258 Bitter Orange Fruit, SRM 3259 Bitter Orange Extract, SRM 3260 Bitter Orange-containing Solid Oral Dosage Form, and SRM 3280 Multivitamin/Multielement Tablets. Samples were prepared for analysis using the method of isotope dilution and measured using various operating and sample introduction configurations including standard mode, collision cell with kinetic energy discrimination mode, and standard mode with sample introduction via a desolvating nebulizer system. Three isotope pairs, (112)Cd/(111)Cd, (113)Cd/(111)Cd, and (114)Cd/(111)Cd, were measured. Cadmium mass fraction results for the unseparated samples of each material, measured using the three instrument configurations and isotope pairs, were compared to the results obtained after the matrix was removed via chemical separation using anion exchange chromatography. In four of the six materials studied, measurements using the standard mode with sample introduction via the desolvating nebulizer gave results for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair that showed a positive bias relative to the matrix-separated samples, which indicated a persistent inference at m/z112 with this configuration. Use of the standard mode, without the desolvating nebulizer, also gave results that showed a positive bias for the unseparated samples quantified with the (112)Cd/(111)Cd isotope pair in three of the materials studied. Collision cell/kinetic energy discrimination mode, however, was very effective for reducing spectral interference for Cd in all of the materials and isotope pairs studied, except in the multivitamin/multielement matrix (SRM 3280) where the large corrections for known isobaric interferences or unidentified interferences compromised the accuracy. For SRM 3280, matrix separation provided the best method to achieve accurate measurement of Cd.
Amick, G D
1999-01-01
A database containing names of mass spectral data files generated in a forensic toxicology laboratory and two Microsoft Visual Basic programs to maintain and search this database is described. The data files (approximately 0.5 KB/each) were collected from six mass spectrometers during routine casework. Data files were archived on 650 MB (74 min) recordable CD-ROMs. Each recordable CD-ROM was given a unique name, and its list of data file names was placed into the database. The present manuscript describes the use of search and maintenance programs for searching and routine upkeep of the database and creation of CD-ROMs for archiving of data files.
3D change detection - Approaches and applications
NASA Astrophysics Data System (ADS)
Qin, Rongjun; Tian, Jiaojiao; Reinartz, Peter
2016-12-01
Due to the unprecedented technology development of sensors, platforms and algorithms for 3D data acquisition and generation, 3D spaceborne, airborne and close-range data, in the form of image based, Light Detection and Ranging (LiDAR) based point clouds, Digital Elevation Models (DEM) and 3D city models, become more accessible than ever before. Change detection (CD) or time-series data analysis in 3D has gained great attention due to its capability of providing volumetric dynamics to facilitate more applications and provide more accurate results. The state-of-the-art CD reviews aim to provide a comprehensive synthesis and to simplify the taxonomy of the traditional remote sensing CD techniques, which mainly sit within the boundary of 2D image/spectrum analysis, largely ignoring the particularities of 3D aspects of the data. The inclusion of 3D data for change detection (termed 3D CD), not only provides a source with different modality for analysis, but also transcends the border of traditional top-view 2D pixel/object-based analysis to highly detailed, oblique view or voxel-based geometric analysis. This paper reviews the recent developments and applications of 3D CD using remote sensing and close-range data, in support of both academia and industry researchers who seek for solutions in detecting and analyzing 3D dynamics of various objects of interest. We first describe the general considerations of 3D CD problems in different processing stages and identify CD types based on the information used, being the geometric comparison and geometric-spectral analysis. We then summarize relevant works and practices in urban, environment, ecology and civil applications, etc. Given the broad spectrum of applications and different types of 3D data, we discuss important issues in 3D CD methods. Finally, we present concluding remarks in algorithmic aspects of 3D CD.
A portable spectrometer for use from 5 to 15 micrometers
NASA Technical Reports Server (NTRS)
Hoover, G.; Kahle, A. B.
1986-01-01
A field portable spectrometer suitable for collecting data relevant to remote sensing applications in the 8 to 12 micrometer atmospheric window has been built at the Jet Propulsion Laboratory. The instrument employs a single cooled HgCdTe detector and a continuously variable filter wheel analyzer. The spectral range covered is 5 to 14.5 micrometers and the resolution is approximately 1.5 percent of the wavelength. A description of the hardware is followed by a discussion of the analysis of the spectral data leading to finished emissivity and radiance spectra. A section is devoted to the evaluation of the instrument performance with respect to spectral resolution, radiometric precision, and accuracy. Several examples of spectra acquired in the field are included.
UV-CD12: synchrotron radiation circular dichroism beamline at ANKA
Bürck, Jochen; Roth, Siegmar; Windisch, Dirk; Wadhwani, Parvesh; Moss, David; Ulrich, Anne S.
2015-01-01
Synchrotron radiation circular dichroism (SRCD) is a rapidly growing technique for structure analysis of proteins and other chiral biomaterials. UV-CD12 is a high-flux SRCD beamline installed at the ANKA synchrotron, to which it had been transferred after the closure of the SRS Daresbury. The beamline covers an extended vacuum-UV to near-UV spectral range and has been open for users since October 2011. The current end-station allows for temperature-controlled steady-state SRCD spectroscopy, including routine automated thermal scans of microlitre volumes of water-soluble proteins down to 170 nm. It offers an excellent signal-to-noise ratio over the whole accessible spectral range. The technique of oriented circular dichroism (OCD) was recently implemented for determining the membrane alignment of α-helical peptides and proteins in macroscopically oriented lipid bilayers as mimics of cellular membranes. It offers improved spectral quality <200 nm compared with an OCD setup adapted to a bench-top instrument, and accelerated data collection by a factor of ∼3. In addition, it permits investigations of low hydrated protein films down to 130 nm using a rotatable sample cell that avoids linear dichroism artifacts. PMID:25931105
NASA Technical Reports Server (NTRS)
Sato, Goro; Parsons, Ann; Hillinger, Derek; Suzuki, Masaya; Takahashi, Tadayuki; Tashiro, Makoto; Nakazawa, Kazuhiro; Okada, Yuu; Takahashi, Hiromitsu; Watanabe, Shin
2005-01-01
The properties of 32K CdZnTe (4 x 4 sq mm large, 2 mm thick) detectors have been studied in the pre-flight calibration of the Burst Alert Telescope (BAT) on-board the Swift Gamma-ray Burst Explorer (scheduled for launch in November 2004). In order to understand the energy response of the BAT CdZnTe array, we first quantify the mobility-lifetime (mu tau) products of carriers in individual CdZnTe detectors, which produce a position dependency in the charge induction efficiency and results in a low energy tail in the energy spectrum. Based on a new method utilizing (57)Co spectra obtained at different bias voltages, the mu tau for electrons ranges from 5.0 x 10(exp -4) to 1.0 x 10(exp -2) sq cm/V while the mu tau for holes ranges from 1.3 x 10(exp -5 to 1.8 x 10(exp -4) sq cm/V. We find that this wide distribution of mu tau products explains the large diversity in spectral shapes between CdZnTe detectors well. We also find that the variation of mu tau products can be attributed to the difference of crystal ingots or manufacturing harness. We utilize the 32K sets of extracted mu tau products to develop a spectral model of the detector. In combination with Monte Carlo simulations, we can construct a spectral model for any photon energy or any incident angle.
NASA Astrophysics Data System (ADS)
Ajibade, Peter A.; Ejelonu, Benjamin C.
2013-09-01
Zn(II), Cd(II) and Hg(II) dithiocarbamate complexes have been synthesized and characterized by elemental analysis, thermogravimetric analysis, UV-Vis, FTIR, 1H- and 13C NMR spectroscopy. The complexes were thermolysed at 180 °C and used as single molecule precursors for the synthesis of HDA capped ZnS, CdS and HgS nanoparticles and polymethylmethacrylate (PMMA) nanocomposites. The optical and structural properties of the nanoparticles and nanocomposites were studied by UV-Vis, PL, XRD and SEM. The crystallites sizes of the nanoparticles varied between 3.03 and 23.45 nm. SEM and EDX analyses of the nanocomposites confirmed the presence of the nanoparticles in the polymer matrix.
NASA Astrophysics Data System (ADS)
Onwudiwe, Damian C.; Strydom, Christien A.
2015-01-01
Bipyridine adducts of N-phenyldithiocarbamato complexes, [ML12L2] (M = Cd(II), Zn(II); L1 = N-phenyldithiocarbamate, L2 = 2,2‧ bipyridine), have been synthesized and characterised. The decomposition of these complexes to metal sulphides has been investigated by thermogravimetric analysis (TGA). The complexes were used as single-source precursors to synthesize MS (M = Zn, Cd) nanoparticles (NPs) passivated by hexadecyl amine (HDA). The growth of the nanoparticles was carried out at two different temperatures: 180 and 220 °C, and the optical and structural properties of the nanoparticles were studied using UV-Vis spectroscopy, photoluminescence spectroscopy (PL), transmission emission microscopy (TEM) and powdered X-ray diffraction (p-XRD). Nanoparticles, whose average diameters are 2.90 and 3.54 nm for ZnS, and 8.96 and 9.76 nm for CdS grown at 180 and 220 °C respectively, were obtained.
Mid-infrared Plasmonic Circular Dichroism Generated by Graphene Nanodisk Assemblies.
Kong, Xiang-Tian; Zhao, Runbo; Wang, Zhiming; Govorov, Alexander O
2017-08-09
It is very interesting to bring plasmonic circular dichroism spectroscopy to the mid-infrared spectral interval, and there are two reasons for this. This spectral interval is very important for thermal bioimaging, and simultaneously, this spectral range includes vibrational lines of many chiral biomolecules. Here we demonstrate that graphene plasmons indeed offer such opportunity. In particular, we show that chiral graphene assemblies consisting of a few graphene nanodisks can generate strong circular dichroism (CD) in the mid-infrared interval. The CD signal is generated due to the plasmon-plasmon coupling between adjacent nanodisks in the specially designed chiral graphene assemblies. Because of the large dimension mismatch between the thickness of a graphene layer and the incoming light's wavelength, three-dimensional configurations with a total height of a few hundred nanometers are necessary to obtain a strong CD signal in the mid-infrared range. The mid-infrared CD strength is mainly governed by the total dimensions (total height and helix scaffold radius) of the graphene nanodisk assembly and by the plasmon-plasmon interaction strength between its constitutive nanodisks. Both positive and negative CD bands can be observed in the graphene assembly array. The frequency interval of the plasmonic CD spectra overlaps with the vibrational modes of some important biomolecules, such as DNA and many different peptides, giving rise to the possibility of enhancing the vibrational optical activity of these molecular species by attaching them to the graphene assemblies. Simultaneously the spectral range of chiral mid-infrared plasmons in our structures appears near the typical wavelength of the human-body thermal radiation, and therefore, our chiral metastructures can be potentially utilized as optical components in thermal imaging devices.
Frentiu, Tiberiu; Darvasi, Eugen; Butaciu, Sinziana; Ponta, Michaela; Petreus, Dorin; Mihaltan, Alin I; Frentiu, Maria
2014-11-01
A low power and low argon consumption (13.56 MHz, 15 W, 150 ml min(-1)) capacitively coupled plasma microtorch interfaced with a low-resolution microspectrometer and a small-sized electrothermal vaporization Rh coiled-filament as liquid microsample introduction device into the plasma was investigated for the simultaneous determination of several volatile elements of interest for environment. Constructive details, spectral and analytical characteristics, and optimum operating conditions of the laboratory equipment for the simultaneous determination of Ag, Cd, Cu, Pb and Zn requiring low vaporization power are provided. The method involves drying of 10 μl sample at 100°C, vaporization at 1500°C and emission measurement by capture of 20 successive spectral episodes each at an integration time of 500 ms. Experiments showed that emission of elements and plasma background were disturbed by the presence of complex matrix and hot Ar flow transporting the microsample into plasma. The emission spectrum of elements is simple, dominated by the resonance lines. The analytical system provided detection limits in the ng ml(-1) range: 0.5(Ag); 1.5(Cd); 5.6(Cu); 20(Pb) and 3(Zn) and absolute detection limits of the order of pg: 5(Ag); 15(Cd); 56(Cu); 200(Pb) and 30(Zn). It was demonstrated the utility and capability of the miniaturized analytical system in the simultaneous determination of elements in soil and water sediment using the standard addition method to compensate for the non-spectral effects of alkali and earth alkaline elements. The analysis of eight certified reference materials exhibited reliable results with recovery in the range of 95-108% and precision of 0.5-9.0% for the five examined elements. The proposed miniaturized analytical system is attractive due to the simple construction of the electrothermal vaporization device and microtorch, low costs associated to plasma generation, high analytical sensitivity and easy-to-run for simultaneous multielemental analysis of liquid microsamples. Copyright © 2014. Published by Elsevier B.V.
Stalin, T; Devi, R Anitha; Rajendiran, N
2005-09-01
Spectral characteristics of ortho, meta and para dihydroxy benzenes (DHB's) have been studied in different solvents, pH and beta-cyclodextrin. Solvent study shows that: (i) the interaction of OH group with the aromatic ring is less than that of amino group both in the ground and excited states, (ii) in absorption, the charge transfer interaction of OH group in para position is larger than ortho and meta positions. pH studies reveals that DHB's are more acidic than phenol. The higher pK(a) value of oDHB (monoanion-dianion) indicates that the formed monoanion is more stabilized by intramolecular hydrogen bonding. DHB's forms a 1:1 inclusion complex with beta-CD. In beta-CD medium, absorption spectra of DHB's mono and dianions shows unusual blue shifts, whereas in the excited state, the spectral characteristics of DHB's follow the same trend in both aqueous and beta-CD medium.
Accurate secondary structure prediction and fold recognition for circular dichroism spectroscopy
Micsonai, András; Wien, Frank; Kernya, Linda; Lee, Young-Ho; Goto, Yuji; Réfrégiers, Matthieu; Kardos, József
2015-01-01
Circular dichroism (CD) spectroscopy is a widely used technique for the study of protein structure. Numerous algorithms have been developed for the estimation of the secondary structure composition from the CD spectra. These methods often fail to provide acceptable results on α/β-mixed or β-structure–rich proteins. The problem arises from the spectral diversity of β-structures, which has hitherto been considered as an intrinsic limitation of the technique. The predictions are less reliable for proteins of unusual β-structures such as membrane proteins, protein aggregates, and amyloid fibrils. Here, we show that the parallel/antiparallel orientation and the twisting of the β-sheets account for the observed spectral diversity. We have developed a method called β-structure selection (BeStSel) for the secondary structure estimation that takes into account the twist of β-structures. This method can reliably distinguish parallel and antiparallel β-sheets and accurately estimates the secondary structure for a broad range of proteins. Moreover, the secondary structure components applied by the method are characteristic to the protein fold, and thus the fold can be predicted to the level of topology in the CATH classification from a single CD spectrum. By constructing a web server, we offer a general tool for a quick and reliable structure analysis using conventional CD or synchrotron radiation CD (SRCD) spectroscopy for the protein science research community. The method is especially useful when X-ray or NMR techniques fail. Using BeStSel on data collected by SRCD spectroscopy, we investigated the structure of amyloid fibrils of various disease-related proteins and peptides. PMID:26038575
NASA Astrophysics Data System (ADS)
Peng, Xuefeng; Wu, Pinghui; Han, Yinxia; Hu, Guoqiang
2014-11-01
The properties of amplified spontaneous emission (ASE) in CdSe/ZnS quantum dot (QD) doped step-index polymer optical fibers (POFs) were computationally analyzed in this paper. A theoretical model based on the rate equations between two main energy levels of CdSe/ZnS QD was built in terms of time (t), distance traveled by light (z) and wavelength (λ), which can describe the ASE successfully. Through analyzing the spectral evolution with distance of the pulses propagating along the CdSe/ZnS QD doped POFs, dependences of the ASE threshold and the slope efficiency on the numerical aperture were obtained. Compared to the ASE in common dye-doped POFs, the pump threshold was just about 1/1000, but the slope efficiency was much higher.
Ajibade, Peter A; Ejelonu, Benjamin C
2013-09-01
Zn(II), Cd(II) and Hg(II) dithiocarbamate complexes have been synthesized and characterized by elemental analysis, thermogravimetric analysis, UV-Vis, FTIR, (1)H- and (13)C NMR spectroscopy. The complexes were thermolysed at 180 °C and used as single molecule precursors for the synthesis of HDA capped ZnS, CdS and HgS nanoparticles and polymethylmethacrylate (PMMA) nanocomposites. The optical and structural properties of the nanoparticles and nanocomposites were studied by UV-Vis, PL, XRD and SEM. The crystallites sizes of the nanoparticles varied between 3.03 and 23.45 nm. SEM and EDX analyses of the nanocomposites confirmed the presence of the nanoparticles in the polymer matrix. Copyright © 2013 Elsevier B.V. All rights reserved.
Spectral characteristics of tramadol in different solvents and β-cyclodextrin
NASA Astrophysics Data System (ADS)
Anton Smith, A.; Manavalan, R.; Kannan, K.; Rajendiran, N.
2009-10-01
Effect of solvents and β-cyclodextrin on the absorption and fluorescence spectra of tramadol drug has been investigated and compared with anisole. The solid inclusion complex of tramadol with β-CD is investigated by FT-IR, 1H NMR, scanning electron microscope (SEM), DSC and semiempirical methods. The thermodynamic parameter (Δ G) of inclusion process is determined. A solvent study shows (i) the spectral behaviour of both tramadol and anisole molecules is similar to each other and (ii) the cyclohexanol group in tramadol is not effectively conjugated with anisole group. However, in β-CD, due to space restriction of the CD cavity, a weak interaction is present between the above groups in tramadol. β-Cyclodextrin studies show that tramadol forms 1:2 inclusion complex with β-CD. A mechanism is proposed for the inclusion process.
Dual fluorescence of N-phenylanthranilic acid: Effect of solvents, pH and beta-cyclodextrin.
Rajendiran, N; Balasubramanian, T
2007-11-01
Spectral characteristics of N-phenylanthranilic acid (NPAA) have been studied in different solvents, pH and beta-cyclodextrin (beta-CD) and compared with anthranilic acid (2-aminobenzoic acid, 2ABA). In all solvents a dual fluorescence is observed in NPAA, whereas 2ABA gives single emission. Combining the results observed in the absorption, fluorescence emission and fluorescence excitation spectra, it is found that strong intramolecular hydrogen bonding (IHB) interactions present in NPAA molecule. The inclusion complex of NPAA with beta-CD is analysed by UV-vis, fluorimetry, FT-IR, (1)H NMR, scanning electron microscope and AM 1 method. The above spectral studies show that NPAA forms a 1:1 inclusion complex with beta-CD and COOH group present in the beta-CD cavity. A mechanism is proposed to explain the inclusion process.
Dual fluorescence of N-phenylanthranilic acid: Effect of solvents, pH and β-cyclodextrin
NASA Astrophysics Data System (ADS)
Rajendiran, N.; Balasubramanian, T.
2007-11-01
Spectral characteristics of N-phenylanthranilic acid (NPAA) have been studied in different solvents, pH and β-cyclodextrin (β-CD) and compared with anthranilic acid (2-aminobenzoic acid, 2ABA). In all solvents a dual fluorescence is observed in NPAA, whereas 2ABA gives single emission. Combining the results observed in the absorption, fluorescence emission and fluorescence excitation spectra, it is found that strong intramolecular hydrogen bonding (IHB) interactions present in NPAA molecule. The inclusion complex of NPAA with β-CD is analysed by UV-vis, fluorimetry, FT-IR, 1H NMR, scanning electron microscope and AM 1 method. The above spectral studies show that NPAA forms a 1:1 inclusion complex with β-CD and COOH group present in the β-CD cavity. A mechanism is proposed to explain the inclusion process.
Study of polarization phenomena in Schottky CdTe diodes using infrared light illumination
NASA Astrophysics Data System (ADS)
Sato, Goro; Fukuyama, Taro; Watanabe, Shin; Ikeda, Hirokazu; Ohta, Masayuki; Ishikawa, Shin'nosuke; Takahashi, Tadayuki; Shiraki, Hiroyuki; Ohno, Ryoichi
2011-10-01
Schottky CdTe diode detectors suffer from a polarization phenomenon, which is characterized by degradation of the spectral properties over time following exposure to high bias voltage. This is considered attributable to charge accumulation at deep acceptor levels. A Schottky CdTe diode was illuminated with an infrared light for a certain period during a bias operation, and two opposite behaviors emerged. The detector showed a recovery when illuminated after the bias-induced polarization had completely progressed. Conversely, when the detector was illuminated before the emergence of bias-induced polarization, the degradation of the spectral properties was accelerated. Interpretation of these effects and discussion on the energy level of deep acceptors are presented.
Spectral response characterization of CdTe sensors of different pixel size with the IBEX ASIC
NASA Astrophysics Data System (ADS)
Zambon, P.; Radicci, V.; Trueb, P.; Disch, C.; Rissi, M.; Sakhelashvili, T.; Schneebeli, M.; Broennimann, C.
2018-06-01
We characterized the spectral response of CdTe sensors with different pixel sizes - namely 75, 150 and 300 μm - bonded to the latest generation IBEX single photon counting ASIC developed at DECTRIS, to detect monochromatic X-ray energy in the range 10-60 keV. We present a comparison of pulse height spectra recorded for several energies, showing the dependence on the pixel size of the non-trivial atomic fluorescence and charge sharing effects that affect the detector response. The extracted energy resolution, in terms of full width at half maximum or FWHM, ranges from 1.5 to 4 keV according to the pixel size and chip configuration. We devoted a careful analysis to the Quantum Efficiency and to the Spectral Efficiency - a newly-introduced measure that quantifies the impact of fluorescence and escape phenomena on the spectrum integrity in high- Z material based detectors. We then investigated the influence of the photon flux on the aforementioned quantities up to 180 ṡ 106 cts/s/mm2 and 50 ṡ 106 cts/s/mm2 for the 150 μm and 300 μm pixel case, respectively. Finally, we complemented the experimental data with analytical and with Monte Carlo simulations - taking into account the stochastic nature of atomic fluorescence - with an excellent agreement.
Extending the spectral range of CdSe/ZnSe quantum wells by strain engineering
NASA Astrophysics Data System (ADS)
Finke, A.; Ruth, M.; Scholz, S.; Ludwig, A.; Wieck, A. D.; Reuter, D.; Pawlis, A.
2015-01-01
We demonstrate efficient room-temperature photoluminescence and spectral tuning of epitaxially grown ZnSe/CdSe quantum well structures almost over the whole visible spectrum (470-600 nm wavelength). The key element to achieve the observed high quantum efficiency and enormous tuning range was the implementation of a special strain engineering technique, which allows us to suppress substantial lattice relaxation of CdSe on ZnSe. Previous studies indicated that a CdSe coverage exceeding 3 ML on ZnSe results in the formation of extensive lattice defects and complete quenching of the photoluminescence at low and room temperature. In contrast, our approach of strain engineering enables the deposition of planar CdSe quantum wells with a thickness ranging from 1 to 6 ML with excellent optical properties. We attribute the observed experimental features to a controllable strain compensation effect that is present in an alternating system of tensile and compressively strained epitaxial layers and supported this model by calculations of the transition energies of the ZnSe/CdSe quantum wells.
NASA Astrophysics Data System (ADS)
Putra, Alfian; Vassileva, Maria; Santo, Ryoko; Tsenkova, Roumina
2017-06-01
Cadmium (Cd) is a common industrial pollutant with long biological half-life, which makes it as a cumulative toxicant. Near-infrared spectroscopy has been successfully used for quick and accurate assessment of Cd content in agricultural materials, but the development of a quick detection method for ground and drinking water samples is equal importance for pollution monitoring. Metals have no absorbance in the NIR spectral range, thus the methods developed so far have focused on detection of metal-organic complexes (move to intro). This study focuses on the use of Aquaphotomics technique to measure Cd in aqueous solutions by analyzing the changes in water spectra that occur due to water-metal interaction. Measurements were performed with Cd (II) in 0.1 M HNO3, in the 680-1090 nm (water second and third overtones) and 1110-1800 nm (water first overtone) spectral regions, and were subjected to partial least-square regression analysis. It was found/determined that A concentration of Cd from 1 mg L-1 to 10 mg L-1 could be predicted by this model with average prediction correlation coefficient of 0.897. The model was tested by perturbations with temperature and other metal presence in the solution. The regression coefficient showed consistent peaks at 728, 752, 770, 780, 1362, 1430,1444, 1472/1474 and 1484 nm under various perturbations, indicating that metal to influence the water spectra. The residual predictive deviation values (RPD) were greater than 2, indicating that the model is appropriate for practical use. The result suggested that this newly proposed approach is capable of detecting metal ion in a much simpler, rapid and reliable way.
Boles, Georgia C; Hightower, Randy L; Coates, Rebecca A; McNary, Christopher P; Berden, Giel; Oomens, Jos; Armentrout, P B
2018-04-12
Complexes of aspartic acid (Asp) cationized with Zn 2+ : Zn(Asp-H) + , Zn(Asp-H) + (ACN) where ACN = acetonitrile, and Zn(Asp-H) + (Asp); as well as with Cd 2+ , CdCl + (Asp), were examined by infrared multiple photon dissociation (IRMPD) action spectroscopy using light generated from a free electron laser. A series of low-energy conformers for each complex was found using quantum chemical calculations to identify the structures formed experimentally. The main binding motif observed for the heavy-metal complex, CdCl + (Asp)[N,CO,CO s ], is a charge-solvated, tridentate structure, where the metal center binds to the backbone amino group and carbonyl oxygens of the backbone and side-chain carboxylic acids. Likewise, the deprotonated Zn(Asp-H) + (ACN) and Zn(Asp-H) + (Asp) complexes show comparable [N,CO - ,CO s ](ACN) and [N,CO - ,CO s ][N,CO,CO s ] coordinations, respectively. Interestingly, there was only minor spectral evidence for the analogous Zn(Asp-H) + [N,CO - ,CO s ] binding motif, even though this species is predicted to be the lowest-energy conformer. Instead, rearrangement and partial dissociation of the amino acid are observed, as spectral features most consistent with the experimental spectrum are exhibited by a four-coordinate Zn(Asp-NH 4 ) + [CO 2 - ,CO s ](NH 3 ) complex. Analysis of the mechanistic pathway leading from the predicted lowest-energy conformer to the isobaric deaminated complex is explored theoretically. Further, comparison of the current work to that of Zn 2+ and Cd 2+ complexes of asparagine (Asn) allows additional conclusions regarding populated conformers and effects of carboxamide versus carboxylic acid binding to be drawn.
Onwudiwe, Damian C; Strydom, Christien A
2015-01-25
Bipyridine adducts of N-phenyldithiocarbamato complexes, [ML(1)2L(2)] (M=Cd(II), Zn(II); L(1)=N-phenyldithiocarbamate, L(2)=2,2' bipyridine), have been synthesized and characterised. The decomposition of these complexes to metal sulphides has been investigated by thermogravimetric analysis (TGA). The complexes were used as single-source precursors to synthesize MS (M=Zn, Cd) nanoparticles (NPs) passivated by hexadecyl amine (HDA). The growth of the nanoparticles was carried out at two different temperatures: 180 and 220 °C, and the optical and structural properties of the nanoparticles were studied using UV-Vis spectroscopy, photoluminescence spectroscopy (PL), transmission emission microscopy (TEM) and powdered X-ray diffraction (p-XRD). Nanoparticles, whose average diameters are 2.90 and 3.54 nm for ZnS, and 8.96 and 9.76 nm for CdS grown at 180 and 220 °C respectively, were obtained. Copyright © 2014 Elsevier B.V. All rights reserved.
Onwudiwe, Damian C; Strydom, Christien A; Oluwafemi, Oluwatobi S; Hosten, Eric; Jordaan, Anine
2014-06-21
The synthesis, spectroscopic characterisation, and thermal studies of pyridyl adducts of Zn(II) and Cd(II) complexes of N-ethyl-N-phenyl dithiocarbamate, represented as [ZnL2py] and [CdL2py2], are reported. Single-crystal X-ray structural analysis of the Zn compound showed that it is five-coordinate with four sulphurs from dithiocarbamate and one nitrogen from pyridine in a distorted square pyramidal geometry. The thermogravimetric studies indicate that the zinc and cadmium compounds undergo fast weight loss, and the temperature at maximum rate of decomposition is at 277 °C and 265 °C respectively, to give the metal (Zn or Cd) sulphide residues. These compounds were used as single molecule precursors to produce nanocrystalline MS (M = Zn, Cd) after thermolysis in hexadecylamine. The morphological and optical properties of the resulting MS nanocrystallites were investigated using transmission electron microscopy (TEM), scanning electron microscopy (SEM), UV-Vis absorption and photoluminescence (PL) spectroscopy, and powdered X-ray diffraction (XRD). By varying the growth time, the temporal evolution of the optical properties and morphology of the nanocrystals were investigated.
Luminescence of CdSe/ZnS quantum dots infiltrated into an opal matrix
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gruzintsev, A. N.; Emelchenko, G. A.; Masalov, V. M.
The effect of the photonic band gap in the photonic crystal, the synthesized SiO{sub 2} opal with embedded CdSe/ZnS quantum dots, on its luminescence in the visible spectral region is studied. It is shown that the position of the photonic band gap in the luminescence and reflectance spectra for the infiltrated opal depends on the diameter of the constituent nanospheres and on the angle of recording the signal. The optimal conditions for embedding the CdSe/ZnS quantum dots from the solution into the opal matrix are determined. It is found that, for the opal-CdSe/ZnS nanocomposites, the emission intensity decreases and themore » luminescence decay time increases in the spatial directions, in which the spectral positions of the photonic band gap and the luminescence peak of the quantum dots coincide.« less
NASA Astrophysics Data System (ADS)
Slyusarenko, N. V.; Gerasimova, M. A.; Slabko, V. V.; Slyusareva, E. A.
2017-07-01
Polymer particles with sizes 0.3-0.4 μm are synthesized based on chitosan and chondroitin sulfate with incorporated CdTe (core) and CdSe/ZnS (core-shell) quantum dots. Their morphological and spectral properties are investigated by the methods of dynamic scattering, electron microscopy, and absorption and luminescence spectroscopy at temperatures from 10 to 80°C. Spectral effects associated with a change in temperature (a red shift and a decrease in the amplitude of the photoluminescence spectrum) can be explained by the temperature expansion of the quantum dots and activation of surface traps. It is shown that the temperature sensitivity of spectra of the quantum dots incorporated into the biopolymer particles is not less than in water. To develop an optical temperature sensor, the core quantum dots are more preferable than the core-shell quantum dots.
A comparison of reliability of soil Cd determination by standard spectrometric methods
McBride, M.B.
2015-01-01
Inductively coupled plasma emission spectrometry (ICP-OES) is the most common method for determination of soil Cd, yet spectral and matrix interferences affect measurements at the available analytical wavelengths for this metal. This study evaluated the severity of the interference over a range of total soil Cd by comparing ICP-OES and ICP-MS measurements of Cd in acid digests. ICP-OES using the emission at 226.5 nm generally unable to quantify soil Cd at low (near-background) levels, and gave unreliable values compared to ICP-MS. Using the line at 228.nm, a marked positive bias in Cd measurement (relative to the 226.5 nm measurement) was attributable to As interference even at soil As concentrations below 10 mg/kg. This spectral interference in ICP-OES was severe in As-contaminated orchard soils, giving a false value for soil total Cd near 2 mg kg−1 when soil As was 100–150 mg kg−1. In attempting to avoid these ICP emission-specific interferences, we evaluated a method to estimate total soil Cd using 1 M HNO3 extraction followed by determination of Cd by flame atomic absorption (FAA), either with or without pre-concentration of Cd using an Aliquat-heptanone extractant. The 1 M HNO3 extracted an average of 82% of total soil Cd. The FAA method had no significant interferences, and estimated the total Cd concentrations in all soils tested with acceptable accuracy. For Cd-contaminated soils, the Aliquat-heptanone pre-concentration step was not necessary, as FAA sensitivity was adequate for quantification of extractable soil Cd and reliable estimation of total soil Cd. PMID:22031569
Surface Passivation of CdZnTe Detector by Hydrogen Peroxide Solution Etching
NASA Technical Reports Server (NTRS)
Hayes, M.; Chen, H.; Chattopadhyay, K.; Burger, A.; James, R. B.
1998-01-01
The spectral resolution of room temperature nuclear radiation detectors such as CdZnTe is usually limited by the presence of conducting surface species that increase the surface leakage current. Studies have shown that the leakage current can be reduced by proper surface preparation. In this study, we try to optimize the performance of CdZnTe detector by etching the detector with hydrogen peroxide solution as function of concentration and etching time. The passivation effect that hydrogen peroxide introduces have been investigated by current-voltage (I-V) measurement on both parallel strips and metal-semiconductor-metal configurations. The improvements on the spectral response of Fe-55 and 241Am due to hydrogen peroxide treatment are presented and discussed.
NASA Astrophysics Data System (ADS)
Güler, Günnur; Vorob'ev, Mikhail M.; Vogel, Vitali; Mäntele, Werner
2016-05-01
Enzymatically-induced degradation of bovine serum albumin (BSA) by serine proteases (trypsin and α-chymotrypsin) in various concentrations was monitored by means of Fourier transform infrared (FT-IR) and ultraviolet circular dichroism (UV-CD) spectroscopy. In this study, the applicability of both spectroscopies to monitor the proteolysis process in real time has been proven, by tracking the spectral changes together with secondary structure analysis of BSA as proteolysis proceeds. On the basis of the FTIR spectra and the changes in the amide I band region, we suggest the progression of proteolysis process via conversion of α-helices (1654 cm- 1) into unordered structures and an increase in the concentration of free carboxylates (absorption of 1593 and 1402 cm- 1). For the first time, the correlation between the degree of hydrolysis and the concentration of carboxylic groups measured by FTIR spectroscopy was revealed as well. The far UV-CD spectra together with their secondary structure analysis suggest that the α-helical content decreases concomitant with an increase in the unordered structure. Both spectroscopic techniques also demonstrate that there are similar but less spectral changes of BSA for the trypsin attack than for α-chymotrypsin although the substrate/enzyme ratio is taken the same.
NASA Astrophysics Data System (ADS)
Saeidifar, Maryam; Mirzaei, Hamidreza; Ahmadi Nasab, Navid; Mansouri-Torshizi, Hassan
2017-11-01
The binding ability between a new water-soluble palladium(II) complex [Pd(bpy)(bez-dtc)]Cl (where bpy is 2,2‧-bipyridine and bez-dtc is benzyl dithiocarbamate), as an antitumor agent, and calf thymus DNA was evaluated using various physicochemical methods, such as UV-Vis absorption, Competitive fluorescence studies, viscosity measurement, zeta potential and circular dichroism (CD) spectroscopy. The Pd(II) complex was synthesized and characterized using elemental analysis, molar conductivity measurements, FT-IR, 1H NMR, 13C NMR and electronic spectra studies. The anticancer activity against HeLa cell lines demonstrated lower cytotoxicity than cisplatin. The binding constants and the thermodynamic parameters were determined at different temperatures (300 K, 310 K and 320 K) and shown that the complex can bind to DNA via electrostatic forces. Furthermore, this result was confirmed by the viscosity and zeta potential measurements. The CD spectral results demonstrated that the binding of Pd(II) complex to DNA induced conformational changes in DNA. We hope that these results will provide a basis for further studies and practical clinical use of anticancer drugs.
Kakuda, Rie; Machida, Koichi; Yaoita, Yasunori; Kikuchi, Masafumi; Kikuchi, Masao
2003-07-01
A new triterpenoid, 12-ursene-3beta, 11alpha-diol 3-O-palmitate (1), has been isolated from the rhizomes and roots of Gentiana lutea, together with the artificial diene derivative, 9 (11), 12-ursadien-3beta-ol 3-O-palmitate (1a) and five known compounds (3-7). Their structures were established on the basis of spectral analysis. In addition, (+/-)-gentiolactone [(+/-)-2], isolated from this plant, was successfully separated into its enantiomers [(+)-2, (-)-2] for the first time, and the absolute configurations at C-9 of (+)-2, (-)-2 were assigned as S and R, respectively, from the optical rotations and the circular dichroism (CD) spectral data.
Martin, Laetitia B. B.; Sherwood, Robert W.; Nicklay, Joshua J.; Yang, Yong; Muratore-Schroeder, Tara L.; Anderson, Elizabeth T.; Thannhauser, Theodore W.; Rose, Jocelyn K. C.; Zhang, Sheng
2017-01-01
We describe here the use of label-free wide selected-ion monitoring data-independent acquisition (WiSIM-DIA) to identify proteins that are involved in the formation of tomato (Solanum lycopersicum) fruit cuticles and that are regulated by the transcription factor CUTIN DEFICIENT2 (CD2). A spectral library consisting of 11 753 unique peptides, corresponding to 2338 tomato protein groups, was used and the DIA analysis was performed at the MS1 level utilizing narrow mass windows for extraction with Skyline 2.6 software. We identified a total of 1140 proteins, 67 of which had expression levels that differed significantly between the cd2 tomato mutant and the wild-type cultivar M82. Differentially expressed proteins including a key protein involved in cutin biosynthesis, were selected for validation by target SRM/MRM and by Western blot analysis. In addition to confirming a role for CD2 in regulating cuticle formation, the results also revealed that CD2 influences pathways associated with cell wall biology, anthocyanin biosynthesis, plant development, and responses to stress, which complements findings of earlier RNA-Seq experiments. Our results provide new insights into molecular processes and aspects of fruit biology associated with CD2 function, and demonstrate that the WiSIM-DIA is an effective quantitative approach for global protein identifications. PMID:27089858
Teper, Sławomir J.; Janiszewska, Dominika A.; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
Purpose. To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Methods. Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Results. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Conclusions. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements. PMID:26457303
Nowinska, Anna K; Teper, Sławomir J; Janiszewska, Dominika A; Lyssek-Boron, Anita; Dobrowolski, Dariusz; Koprowski, Robert; Wylegala, Edward
2015-01-01
To compare anterior eye segment measurements and morphology obtained with two optical coherence tomography systems (TD OCT, SS OCT) in eyes with corneal dystrophies (CDs). Fifty healthy volunteers (50 eyes) and 54 patients (96 eyes) diagnosed with CD (epithelial basement membrane dystrophy, EBMD = 12 eyes; Thiel-Behnke CD = 6 eyes; lattice CD TGFBI type = 15 eyes; granular CD type 1 = 7 eyes, granular CD type 2 = 2 eyes; macular CD = 23 eyes; and Fuchs endothelial CD = 31 eyes) were recruited for the study. Automated and manual central corneal thickness (aCCT, mCCT), anterior chamber depth (ACD), and nasal and temporal trabecular iris angle (nTIA, tTIA) were measured and compared with Bland-Altman plots. Good agreement between the TD and SS OCT measurements was demonstrated for mCCT and aCCT in normal individuals and for mCCT in the CDs group. The ACD, nTIA, and tTIA measurements differed significantly in both groups. TBCD, LCD, and FECD caused increased CCT. MCD caused significant corneal thinning. FECD affected all analyzed parameters. Better agreement between SS OCT and TD OCT measurements was demonstrated in normal individuals compared to the CDs group. OCT provides comprehensive corneal deposits analysis and demonstrates the association of CD with CCT, ACD, and TIA measurements.
Micsonai, András; Wien, Frank; Bulyáki, Éva; Kun, Judit; Moussong, Éva; Lee, Young-Ho; Goto, Yuji; Réfrégiers, Matthieu; Kardos, József
2018-06-11
Circular dichroism (CD) spectroscopy is a widely used method to study the protein secondary structure. However, for decades, the general opinion was that the correct estimation of β-sheet content is challenging because of the large spectral and structural diversity of β-sheets. Recently, we showed that the orientation and twisting of β-sheets account for the observed spectral diversity, and developed a new method to estimate accurately the secondary structure (PNAS, 112, E3095). BeStSel web server provides the Beta Structure Selection method to analyze the CD spectra recorded by conventional or synchrotron radiation CD equipment. Both normalized and measured data can be uploaded to the server either as a single spectrum or series of spectra. The originality of BeStSel is that it carries out a detailed secondary structure analysis providing information on eight secondary structure components including parallel-β structure and antiparallel β-sheets with three different groups of twist. Based on these, it predicts the protein fold down to the topology/homology level of the CATH protein fold classification. The server also provides a module to analyze the structures deposited in the PDB for BeStSel secondary structure contents in relation to Dictionary of Secondary Structure of Proteins data. The BeStSel server is freely accessible at http://bestsel.elte.hu.
Lifetime Measurement of HgCdTe Semiconductor Material
2012-03-01
long-wavelength (>15 μm) infrared spectral region. HgCdTe is a very effective infrared detector material because of its different properties. The...properties that make HgCdTe an effective infrared detector are its adjustable bandgap of 0.7 to 25 μm, its high absorption coefficient, its moderate... HgCdTe infrared detectors . Retrieved Jul. 17, 2011, from http://www.wat.edu.pl/review/optor/10(3)159.pdf Wagner, R. J. (1999 Apr. 16). In
Murphy, K E; Long, S E; Vocke, R D
2007-04-01
Analytical methods used for the isotope dilution inductively coupled plasma mass spectrometric (ID-ICP-MS) measurement of Cd at microg kg(-1) and sub-microg kg(-1) levels are described and applied to the certification of new dietary supplement, blood, and serum Standard Reference Materials (SRMs). The materials are: SRM 3240 Ephedra sinica Stapf Aerial Parts, SRM 3241 Ephedra sinica Stapf Native Extract, SRM 3243 Ephedra-Containing Solid Oral Dosage Form, SRM 3244 Ephedra-Containing Protein Powder, SRM 966 Toxic Metals in Bovine Blood, Level 1 (L1) and Level 2 (L2), and SRM 1598a Animal Serum. The concentration of Cd in the materials ranges from 120 microg kg(-1) down to 0.03 microg kg(-1). At these levels, the factors that most influence the accuracy of the ICP-MS data are the procedure blank and spectral and nonspectral interferences. Nonspectral interference, caused by the high concentration of dissolved solids in the matrices investigated, resulted in signal suppression. Matrix separation was used to enhance signal intensity and to reduce spectral interference for the accurate determination of Cd in SRM 1598a and SRM 3244. Chromatographic separation procedures using Chelex for SRM 1598a and anion exchange for SRM 3244 were optimized to achieve the desired separation characteristics without substantially increasing the procedure blank. Sensitivity for the determination of Cd in serum was additionally enhanced through the use of desolvation nebulization. We determined that separations were not required for the accurate ICP-MS determination of Cd in SRM 3240, SRM 3241, SRM 3243, and SRM 966 L2 under optimized analysis conditions. These samples were diluted to a minimum volume and introduced to the ICP-MS via low flow (40-100 microL/min) microconcentric nebulizers. SRM 966 L1 was also analyzed directly, but results were highly variable. The ID-ICP-MS sample preparation and ratio measurement protocols described here resulted in total expanded uncertainties of less than 1% for the determination of 90.85 microg kg(-1) Cd in SRM 3240, and less than 10% total expanded uncertainty for the determination of 0.0468 microg kg(-1) Cd in SRM 1598a.
Solheim, Harald; Kornobis, Karina; Ruud, Kenneth; Kozlowski, Pawel M
2011-02-03
Linear and quadratic response time-dependent density functional theory (TD-DFT) has been applied to investigate absorption (Abs), circular dichroism (CD), and magnetic CD (MCD) spectra of cyanocobalamin (CNCbl) and methylcobalamin (MeCbl). Although electronically excited states of both cobalamins have been probed by applying different experimental techniques, their exact nature remains poorly understood from an electronic structure point of view. Recent theoretical studies have revealed a lot of relevant information about their properties but also left some unresolved issues related to the nature of individual transitions. In this contribution, not only Abs but also CD and MCD spectra of both cobalamins were computed for direct comparison with experiment. The results were evaluated with respect to the choice of exchange-correlation functional, basis set, and the environment (gas phase or solvent) used in the calculation. Taking into account the complexity of the CNCbl and MeCbl systems, reliable agreement between theory and experiment was achieved based on calculations employing the BP86 functional, particularly for the low-energy α/β bands. This spectral range has been traditionally interpreted as a vibrational progression associated with a single electronic excitation, but according to the present analysis for both cobalamins, these bands are best interpreted as consisting of multiple electronic transitions.
Malashchonak, Mikalai V; Korolik, Olga V; Streltsov, Еugene А; Kulak, Anatoly I
2015-01-01
Summary The photoelectrochemical properties of nanoheterostructures based on the wide band gap oxide substrates (ZnO, TiO2, In2O3) and CdS nanoparticles deposited by the successive ionic layer adsorption and reaction (SILAR) method have been studied as a function of the CdS deposition cycle number (N). The incident photon-to-current conversion efficiency (IPCE) passes through a maximum with the increase of N, which is ascribed to the competition between the increase in optical absorption and photocarrier recombination. The maximal IPCE values for the In2O3/CdS and ZnO/CdS heterostructures are attained at N ≈ 20, whereas for TiO2/CdS, the appropriate N value is an order of magnitude higher. The photocurrent and Raman spectroscopy studies of CdS nanoparticles revealed the occurrence of the quantum confinement effect, demonstrating the most rapid weakening with the increase of N in ZnO/CdS heterostructures. The structural disorder of CdS nanoparticles was characterized by the Urbach energy (E U), spectral width of the CdS longitudinal optical (LO) phonon band and the relative intensity of the surface optical (SO) phonon band in the Raman spectra. Maximal values of E U (100–120 meV) correspond to СdS nanoparticles on a In2O3 surface, correlating with the fact that the CdS LO band spectral width and intensity ratio for the CdS SO and LO bands are maximal for In2O3/CdS films. A notable variation in the degree of disorder of CdS nanoparticles is observed only in the initial stages of CdS growth (several tens of deposition cycles), indicating the preservation of the nanocrystalline state of CdS over a wide range of SILAR cycles. PMID:26734517
Malashchonak, Mikalai V; Mazanik, Alexander V; Korolik, Olga V; Streltsov, Еugene А; Kulak, Anatoly I
2015-01-01
The photoelectrochemical properties of nanoheterostructures based on the wide band gap oxide substrates (ZnO, TiO2, In2O3) and CdS nanoparticles deposited by the successive ionic layer adsorption and reaction (SILAR) method have been studied as a function of the CdS deposition cycle number (N). The incident photon-to-current conversion efficiency (IPCE) passes through a maximum with the increase of N, which is ascribed to the competition between the increase in optical absorption and photocarrier recombination. The maximal IPCE values for the In2O3/CdS and ZnO/CdS heterostructures are attained at N ≈ 20, whereas for TiO2/CdS, the appropriate N value is an order of magnitude higher. The photocurrent and Raman spectroscopy studies of CdS nanoparticles revealed the occurrence of the quantum confinement effect, demonstrating the most rapid weakening with the increase of N in ZnO/CdS heterostructures. The structural disorder of CdS nanoparticles was characterized by the Urbach energy (E U), spectral width of the CdS longitudinal optical (LO) phonon band and the relative intensity of the surface optical (SO) phonon band in the Raman spectra. Maximal values of E U (100-120 meV) correspond to СdS nanoparticles on a In2O3 surface, correlating with the fact that the CdS LO band spectral width and intensity ratio for the CdS SO and LO bands are maximal for In2O3/CdS films. A notable variation in the degree of disorder of CdS nanoparticles is observed only in the initial stages of CdS growth (several tens of deposition cycles), indicating the preservation of the nanocrystalline state of CdS over a wide range of SILAR cycles.
Characterization of HgCdTe and HgCdSe Materials for Third Generation Infrared Detectors
2011-12-01
information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. Arizona State University ORSPA...UNIVERSITY December 2011 i ABSTRACT HgCdTe is the dominant material currently in use for infrared (IR) focal- plane-array (FPA) technology. In...using HgCdTe have since been made, and it currently represents the dominant material used in all IR spectral bands, primarily for space and
NASA Technical Reports Server (NTRS)
Hochstein, L. I.; Cronin, S. E.
1984-01-01
Cell-free extracts prepared from Paracoccus halodenitrificans catalyzed the reduction of nitrate to ammonia in the presence of dithionite and methyl viologen. Enzyme activity was located in the soluble fraction and was associated with a cytochrome whose spectral properties resembled those of a cd-type cytochrome. Unlike the sissimilatory cd-cytochrome nitrate reductase associated with the membrane fraction of P. halodenitrificans, this soluble cd-cytochrome did not reduce nitrite to nitrous oxide.
An alternative resource sharing scheme for land mobile satellite services
NASA Technical Reports Server (NTRS)
Yan, Tsun-Yee; Sue, Miles K.
1990-01-01
A preliminary comparison between the two competing channelization concepts for the Land Mobile Satellite Services (LMSS), namely frequency division (FD) and code division (CD), is presented. Both random access and demand-assigned approaches are considered under these concepts. The CD concept is compared with the traditional FD concept based on the system consideration and a projected traffic model. It is shown that CD is not particularly attractive for the first generation Mobile Satellite Services because of the spectral occupancy of the network bandwidth. However, the CD concept is a viable alternative for future systems such as the personal access satellite system (PASS) in the Ka-band spectrum where spectral efficiency is not of prime concern. The effects of power robbing and voice activity factor are incorporated. It was shown that the traditional rule of thumb of dividing the number of raw channels by the voice activity factor to obtain the effective number of channels is only valid asymptotically as the aggregated traffic approaches infinity.
An alternative resource sharing scheme for land mobile satellite services
NASA Astrophysics Data System (ADS)
Yan, Tsun-Yee; Sue, Miles K.
A preliminary comparison between the two competing channelization concepts for the Land Mobile Satellite Services (LMSS), namely frequency division (FD) and code division (CD), is presented. Both random access and demand-assigned approaches are considered under these concepts. The CD concept is compared with the traditional FD concept based on the system consideration and a projected traffic model. It is shown that CD is not particularly attractive for the first generation Mobile Satellite Services because of the spectral occupancy of the network bandwidth. However, the CD concept is a viable alternative for future systems such as the personal access satellite system (PASS) in the Ka-band spectrum where spectral efficiency is not of prime concern. The effects of power robbing and voice activity factor are incorporated. It was shown that the traditional rule of thumb of dividing the number of raw channels by the voice activity factor to obtain the effective number of channels is only valid asymptotically as the aggregated traffic approaches infinity.
NASA Astrophysics Data System (ADS)
Ghanbari Niyaky, S.; Montazerozohori, M.; Masoudiasl, A.; White, J. M.
2017-03-01
In this paper, a combined experimental and theoretical study on a new CdLBr2 complex (L = N1-(2-bromobenzylidene)-N2-(2-((E)-(2-bromobenzylidene) amino)ethyl) ethane-1,2-diamine) synthesized via template method, is described. The crystal structure analysis of the complex indicates that, the Cd(II) ion is centered in a distorted square pyramidal space constructed by three iminic nitrogens of the ligand as well as two bromide anions. More analysis of crystal packing proposed a supramolecular structure stabilized by some non-covalent interactions such as Br⋯Br and Xsbnd H⋯Br (X = N and C) in solid state. Furthermore, 3D Hirshfeld surface analyses and DFT studies were applied for theoretical investigation of the complexes. Theoretical achievements were found in a good agreement with respect to the experimental data. To evaluate the nature of bonding and the strength of the intra and inter-molecular interactions a natural bond orbital (NBO) analysis on the complex structure was performed. Time dependent density functional theory (TD-DFT) was also applied to predict the electronic spectral data of the complex as compared with the experimental ones. CdLBr2 complex as nano-structure compound was also prepared under ultrasonic conditions and characterized by scanning electron microscopy (SEM) and X-ray powder diffraction (XRPD). Finally, it was found that the cadmium complex can be used as a suitable precursor for preparation of CdO nanoparticles via calcination process at 600 °C under air atmosphere.
TU-CD-207-01: Characterization of Breast Tissue Composition Using Spectral Mammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, H; Cho, H; Kumar, N
Purpose: To investigate the feasibility of characterizing the chemical composition of breast tissue, in terms of water and lipid, by using spectral mammography in simulation and postmortem studies. Methods: Analytical simulations were performed to obtain low- and high-energy signals of breast tissue based on previously reported water, lipid, and protein contents. Dual-energy decomposition was used to characterize the simulated breast tissue into water and lipid basis materials and the measured water density was compared to the known value. In experimental studies, postmortem breasts were imaged with a spectral mammography system based on a scanning multi-slit Si strip photon-counting detector. Low-more » and high-energy images were acquired simultaneously from a single exposure by sorting the recorded photons into the corresponding energy bins. Dual-energy material decomposition of the low- and high-energy images yielded individual pixel measurements of breast tissue composition in terms of water and lipid thicknesses. After imaging, each postmortem breast was chemically decomposed into water, lipid and protein. The water density calculated from chemical analysis was used as the reference gold standard. Correlation of the water density measurements between spectral mammography and chemical analysis was analyzed using linear regression. Results: Both simulation and postmortem studies showed good linear correlation between the decomposed water thickness using spectral mammography and chemical analysis. The slope of the linear fitting function in the simulation and postmortem studies were 1.15 and 1.21, respectively. Conclusion: The results indicate that breast tissue composition, in terms of water and lipid, can be accurately measured using spectral mammography. Quantitative breast tissue composition can potentially be used to stratify patients according to their breast cancer risk.« less
Yang, Ling Yu; Gao, Xiao Hong; Zhang, Wei; Shi, Fei Fei; He, Lin Hua; Jia, Wei
2016-06-01
In this study, we explored the feasibility of estimating the soil heavy metal concentrations using the hyperspectral satellite image. The concentration of As, Pb, Zn and Cd elements in 48 topsoil samples collected from the field in Yushu County of the Sanjiangyuan regions was measured in the laboratory. We then extracted 176 vegetation spectral reflectance bands of 48 soil samples as well as five vegetation indices from two Hyperion images. Following that, the partial least squares regression (PLSR) method was employed to estimate the soil heavy metal concentrations using the above two independent sets of Hyperion-derived variables, separately constructed the estimation model between the 176 vegetation spectral reflectance bands and the soil heavy metal concentrations (called the vegetation spectral reflectance-based estimation model), and between the five vegetation indices being used as the independent variable and the soil heavy metal concentrations (called synthetic vegetation index-based estimation model). Using RPD (the ratio of standard deviation from the 4 heavy metals measured values of the validation samples to RMSE) as the validation criteria, the RPDs of As and Pb concentrations from the two models were both less than 1.4, which suggested that both models were incapable of roughly estimating As and Pb concentrations; whereas the RPDs of Zn and Cd were 1.53, 1.46 and 1.46, 1.42, respectively, which implied that both models had the ability for rough estimation of Zn and Cd concentrations. Based on those results, the vegetation spectral-based estimation model was selected to obtain the spatial distribution map of Zn concentration in combination with the Hyperion image. The estimated Zn map showed that the zones with high Zn concentrations were distributed near the provincial road 308, national road 214 and towns, which could be influenced by human activities. Our study proved that the spectral reflectance of Hyperion image was useful in estimating the soil concentrations of Zn and Cd.
NASA Astrophysics Data System (ADS)
Steadman, Roger; Herrmann, Christoph; Livne, Amir
2017-08-01
Spectral CT based on energy-resolving photon counting detectors is expected to deliver additional diagnostic value at a lower dose than current state-of-the-art CT [1]. The capability of simultaneously providing a number of spectrally distinct measurements not only allows distinguishing between photo-electric and Compton interactions but also discriminating contrast agents that exhibit a K-edge discontinuity in the absorption spectrum, referred to as K-edge Imaging [2]. Such detectors are based on direct converting sensors (e.g. CdTe or CdZnTe) and high-rate photon counting electronics. To support the development of Spectral CT and show the feasibility of obtaining rates exceeding 10 Mcps/pixel (Poissonian observed count-rate), the ChromAIX ASIC has been previously reported showing 13.5 Mcps/pixel (150 Mcps/mm2 incident) [3]. The ChromAIX has been improved to offer the possibility of a large area coverage detector, and increased overall performance. The new ASIC is called ChromAIX2, and delivers count-rates exceeding 15 Mcps/pixel with an rms-noise performance of approximately 260 e-. It has an isotropic pixel pitch of 500 μm in an array of 22×32 pixels and is tile-able on three of its sides. The pixel topology consists of a two stage amplifier (CSA and Shaper) and a number of test features allowing to thoroughly characterize the ASIC without a sensor. A total of 5 independent thresholds are also available within each pixel, allowing to acquire 5 spectrally distinct measurements simultaneously. The ASIC also incorporates a baseline restorer to eliminate excess currents induced by the sensor (e.g. dark current and low frequency drifts) which would otherwise cause an energy estimation error. In this paper we report on the inherent electrical performance of the ChromAXI2 as well as measurements obtained with CZT (CdZnTe)/CdTe sensors and X-rays and radioactive sources.
Imaging as characterization techniques for thin-film cadmium telluride photovoltaics
NASA Astrophysics Data System (ADS)
Zaunbrecher, Katherine
The goal of increasing the efficiency of solar cell devices is a universal one. Increased photovoltaic (PV) performance means an increase in competition with other energy technologies. One way to improve PV technologies is to develop rapid, accurate characterization tools for quality control. Imaging techniques developed over the past decade are beginning to fill that role. Electroluminescence (EL), photoluminescence (PL), and lock-in thermography are three types of imaging implemented in this study to provide a multifaceted approach to studying imaging as applied to thin-film CdTe solar cells. Images provide spatial information about cell operation, which in turn can be used to identify defects that limit performance. This study began with developing EL, PL, and dark lock-in thermography (DLIT) for CdTe. Once imaging data were acquired, luminescence and thermography signatures of non-uniformities that disrupt the generation and collection of carriers were identified and cataloged. Additional data acquisition and analysis were used to determine luminescence response to varying operating conditions. This includes acquiring spectral data, varying excitation conditions, and correlating luminescence to device performance. EL measurements show variations in a cell's local voltage, which include inhomogeneities in the transparent-conductive oxide (TCO) front contact, CdS window layer, and CdTe absorber layer. EL signatures include large gradients, local reduction of luminescence, and local increases in luminescence on the interior of the device as well as bright spots located on the cell edges. The voltage bias and spectral response were analyzed to determine the response of these non-uniformities and surrounding areas. PL images of CdTe have not shown the same level of detail and features compared to their EL counterparts. Many of the signatures arise from reflections and severe inhomogeneities, but the technique is limited by the external illumination source used to excite carriers. Measurements on unfinished CdS and CdTe films reveal changes in signal after post-deposition processing treatments. DLIT images contained heat signatures arising from defect-related current crowding. Forward- and reverse-bias measurements revealed hot spots related to shunt and weak-diode defects. Modeling and previous studies done on Cu(In,Ga)Se 2 thin-film solar cells aided in identifying the physical causes of these thermographic and luminescence signatures. Imaging data were also coupled with other characterization techniques to provide a more comprehensive examination of nonuniform features and their origins and effects on device performance. These techniques included light-beam-induced-current (LBIC) measurements, which provide spatial quantum efficiency maps of the cell at varying resolutions, as well as time-resolved photoluminescence and spectral PL mapping. Local drops in quantum efficiency seen in LBIC typically corresponded with reductions in EL signal while minority-carrier lifetime values acquired by time-resolved PL measurements correlate with PL intensity.
Jiang, Jian-Bing; Bian, Guo-Qing; Zhang, Ya-Ping; Luo, Wen; Zhu, Qin-Yu; Dai, Jie
2011-10-07
Three anion-cation compounds 1-3 with formula [M(phen)(3)][Cd(4)(SPh)(10)]·Sol (M = Ru(2+), Fe(2+), and Ni(2+), Sol = MeCN and H(2)O) have been synthesized and characterized by single-crystal analysis. Both the cations and anion are well-known ions, but the properties of the co-assembled compounds are interesting. Molecular structures and charge-transfer between the cations and anions in crystal and even in solution are discussed. These compounds are isomorphous and short inter-ion interactions are found in these crystals, such as π···π stacking and C-H···π contacts. Both spectroscopic and theoretical calculated results indicate that there is anion-cation charge-transfer (ACCT) between the Ru-phen complex dye and the Cd-SPh cluster, which plays an important role in their photophysical properties. The intensity of the fluorescent emission of the [Ru(phen)(3)](2+) is enhanced when the cation interacts with the [Cd(4)(SPh)(10)](2-) anion. The mechanism for the enhancement of photoluminescence has been proposed.
Urbańczyk, T; Krośnicki, M; Kędziorski, A; Koperski, J
2018-05-05
Revisited study of the E 3 Σ 1 + (6 3 S 1 )←A 3 Π 0+ (5 3 P 1 ) transition in CdAr using both theoretical and experimental approach is presented. Systematic detection of the E 3 Σ 1 + in ,υ'←A 3 Π 0+ ,υ″=6 transition frequencies with higher accuracy and spectrally narrower laser extended and improved analysis and simulation of the LIF excitation spectrum. More consistent characterization of the E 3 Σ 1 + in -Rydberg state inner well using inversed perturbation approach methodology was achieved. Free←bound transitions in the E 3 Σ 1 + in ←A 3 Π 0+ ,υ″=6 excitation were taken into account in the analysis and simulation of the recorded spectrum. The updated spectroscopic characterization of the A 3 Π 0+ state was also revisited. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Urbańczyk, T.; Krośnicki, M.; Kędziorski, A.; Koperski, J.
2018-05-01
Revisited study of the E3Σ1+ (63S1) ← A3Π0+(53P1) transition in CdAr using both theoretical and experimental approach is presented. Systematic detection of the E3Σ1+in,υ' ← A3Π0+,υ″ = 6 transition frequencies with higher accuracy and spectrally narrower laser extended and improved analysis and simulation of the LIF excitation spectrum. More consistent characterization of the E3Σ1+in-Rydberg state inner well using inversed perturbation approach methodology was achieved. Free ← bound transitions in the E3Σ1+in ← A3Π0+,υ″ = 6 excitation were taken into account in the analysis and simulation of the recorded spectrum. The updated spectroscopic characterization of the A3Π0+ state was also revisited.
Buchholz, Jörg M
2011-07-01
Coloration detection thresholds (CDTs) were measured for a single reflection as a function of spectral content and reflection delay for diotic stimulus presentation. The direct sound was a 320-ms long burst of bandpass-filtered noise with varying lower and upper cut-off frequencies. The resulting threshold data revealed that: (1) sensitivity decreases with decreasing bandwidth and increasing reflection delay and (2) high-frequency components contribute less to detection than low-frequency components. The auditory processes that may be involved in coloration detection (CD) are discussed in terms of a spectrum-based auditory model, which is conceptually similar to the pattern-transformation model of pitch (Wightman, 1973). Hence, the model derives an auto-correlation function of the input stimulus by applying a frequency analysis to an auditory representation of the power spectrum. It was found that, to successfully describe the quantitative behavior of the CDT data, three important mechanisms need to be included: (1) auditory bandpass filters with a narrower bandwidth than classic Gammatone filters, the increase in spectral resolution was here linked to cochlear suppression, (2) a spectral contrast enhancement process that reflects neural inhibition mechanisms, and (3) integration of information across auditory frequency bands. Copyright © 2011 Elsevier B.V. All rights reserved.
[Preparation and spectral characterization of CdS(y)Te(1-y) thin films].
Li, Wei; Feng, Liang-Huan; Wu, Li-Li; Zhang, Jing-Quan; Li, Bing; Lei, Zhi; Cai, Ya-Ping; Zheng, Jia-Gui; Cai, Wei; Zhang, Dong-Min
2008-03-01
CdS(y)Te(1-y) (0 < or = y < or = 1) polycrystalline thin films were prepared on glass substrates by co-evaporation of powders of CdTe and CdS. For the characterization of the structure and composition of the CdS(y)Te(1-y) thin films the X-ray diffraction (XRD) and energy-dispersive spectroscopy (EDS) were used. The results indicate that the values of sulfur content y detected and controlled by the quartz wafer detector show good agreement with the EDS results. The films were found to be cubic for x < 0. 3, and hexagonal for x > or = 0.3. The 20-50 nm of grain sizes for CdS(y)Te(1-y) thin films were calculated using a method of XRD analysis. Finally, the optical properties of CdS(y)Te(1-y) thin films were characterized by UV-Vis-NIR spectroscopy alone. According to a method from Swanepoel, together with the first-order Sellmeier model, the thickness, of d-535 nm, energy gap of E(g)-1.41 eV, absorption coefficient, alpha(lambda) and refractive index, n(lambda) of CdS(0.22) Te(0.78) thin films were determined from the transmittance at normal incidence of light in the wavelength range 300-2 500 nm. The results also indicate that the CdS(y)Te(1-y) thin films with any composition (0 < or = y < or = 1) can be prepared by co-evaporation, and the method to characterize the optical properties of CdS(y)Te(1-y) thin films can be implemented for other semiconductor thin films.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albright, Seth; Chen Bin; Holbrook, Kristen
CD14 functions as a key pattern recognition receptor for a diverse array of Gram-negative and Gram-positive cell-wall components in the host innate immune response by binding to pathogen-associated molecular patterns (PAMPs) at partially overlapping binding site(s). To determine the potential contribution of CD14 residues in this pattern recognition, we have examined using solution NMR spectroscopy, the binding of three different endotoxin ligands, lipopolysaccharide, lipoteichoic acid, and a PGN-derived compound, muramyl dipeptide to a {sup 15}N isotopically labeled 152-residue N-terminal fragment of sCD14 expressed in Pichia pastoris. Mapping of NMR spectral changes upon addition of ligands revealed that the pattern ofmore » residues affected by binding of each ligand is partially similar and partially different. This first direct structural observation of the ability of specific residue combinations of CD14 to differentially affect endotoxin binding may help explain the broad specificity of CD14 in ligand recognition and provide a structural basis for pattern recognition. Another interesting finding from the observed spectral changes is that the mode of binding may be dynamically modulated and could provide a mechanism for binding endotoxins with structural diversity through a common binding site.« less
Spectral correction algorithm for multispectral CdTe x-ray detectors
NASA Astrophysics Data System (ADS)
Christensen, Erik D.; Kehres, Jan; Gu, Yun; Feidenhans'l, Robert; Olsen, Ulrik L.
2017-09-01
Compared to the dual energy scintillator detectors widely used today, pixelated multispectral X-ray detectors show the potential to improve material identification in various radiography and tomography applications used for industrial and security purposes. However, detector effects, such as charge sharing and photon pileup, distort the measured spectra in high flux pixelated multispectral detectors. These effects significantly reduce the detectors' capabilities to be used for material identification, which requires accurate spectral measurements. We have developed a semi analytical computational algorithm for multispectral CdTe X-ray detectors which corrects the measured spectra for severe spectral distortions caused by the detector. The algorithm is developed for the Multix ME100 CdTe X-ray detector, but could potentially be adapted for any pixelated multispectral CdTe detector. The calibration of the algorithm is based on simple attenuation measurements of commercially available materials using standard laboratory sources, making the algorithm applicable in any X-ray setup. The validation of the algorithm has been done using experimental data acquired with both standard lab equipment and synchrotron radiation. The experiments show that the algorithm is fast, reliable even at X-ray flux up to 5 Mph/s/mm2, and greatly improves the accuracy of the measured X-ray spectra, making the algorithm very useful for both security and industrial applications where multispectral detectors are used.
Martin, Laetitia B B; Sherwood, Robert W; Nicklay, Joshua J; Yang, Yong; Muratore-Schroeder, Tara L; Anderson, Elizabeth T; Thannhauser, Theodore W; Rose, Jocelyn K C; Zhang, Sheng
2016-08-01
We describe here the use of label-free wide selected-ion monitoring data-independent acquisition (WiSIM-DIA) to identify proteins that are involved in the formation of tomato (Solanum lycopersicum) fruit cuticles and that are regulated by the transcription factor CUTIN DEFICIENT2 (CD2). A spectral library consisting of 11 753 unique peptides, corresponding to 2338 tomato protein groups, was used and the DIA analysis was performed at the MS1 level utilizing narrow mass windows for extraction with Skyline 2.6 software. We identified a total of 1140 proteins, 67 of which had expression levels that differed significantly between the cd2 tomato mutant and the wild-type cultivar M82. Differentially expressed proteins including a key protein involved in cutin biosynthesis, were selected for validation by target SRM/MRM and by Western blot analysis. In addition to confirming a role for CD2 in regulating cuticle formation, the results also revealed that CD2 influences pathways associated with cell wall biology, anthocyanin biosynthesis, plant development, and responses to stress, which complements findings of earlier RNA-Seq experiments. Our results provide new insights into molecular processes and aspects of fruit biology associated with CD2 function, and demonstrate that the WiSIM-DIA is an effective quantitative approach for global protein identifications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Aldawsari, Abdullah; Khan, Moonis Ali; Hameed, B H; Alqadami, Ayoub Abdullah; Siddiqui, Masoom Raza; Alothman, Zeid Abdullah; Ahmed, A Yacine Badjah Hadj
2017-01-01
A substantive approach converting waste date pits to mercerized mesoporous date pit activated carbon (DPAC) and utilizing it in the removal of Cd(II), Cu(II), Pb(II), and Zn(II) was reported. In general, rapid heavy metals adsorption kinetics for Co range: 25-100 mg/L was observed, accomplishing 77-97% adsorption within 15 min, finally, attaining equilibrium in 360 min. Linear and non-linear isotherm studies revealed Langmuir model applicability for Cd(II) and Pb(II) adsorption, while Freundlich model was fitted to Zn(II) and Cu(II) adsorption. Maximum monolayer adsorption capacities (qm) for Cd(II), Pb(II), Cu(II), and Zn(II) obtained by non-linear isotherm model at 298 K were 212.1, 133.5, 194.4, and 111 mg/g, respectively. Kinetics modeling parameters showed the applicability of pseudo-second-order model. The activation energy (Ea) magnitude revealed physical nature of adsorption. Maximum elution of Cu(II) (81.6%), Zn(II) (70.1%), Pb(II) (96%), and Cd(II) (78.2%) were observed with 0.1 M HCl. Thermogravimetric analysis of DPAC showed a total weight loss (in two-stages) of 28.3%. Infra-red spectral analysis showed the presence of carboxyl and hydroxyl groups over DPAC surface. The peaks at 820, 825, 845 and 885 cm-1 attributed to Zn-O, Pb-O, Cd-O, and Cu-O appeared on heavy metals saturated DPAC, confirmed their binding on DPAC during the adsorption.
Solar excitation of CdS/Cu2S photovoltaic cells
NASA Technical Reports Server (NTRS)
Boer, K. W.
1976-01-01
Solar radiation of five typical clear weather days and under a variety of conditions is used to determine the spectral distribution of the photonflux at different planes of a CdS/Cu2S solar cell. The fractions of reflected and absorbed flux are determined at each of the relevant interfaces and active volume elements of the solar cell. The density of absorbed photons is given in respect to spectral and spatial distribution. The variance of the obtained distribution, with changes in insolation and absorption spectra of the active solar cell layers, is indicated. A catalog of typical examples is given in the appendix.
The U. S. Geological Survey, Digital Spectral Library: Version 1 (0.2 to 3.0um)
Clark, Roger N.; Swayze, Gregg A.; Gallagher, Andrea J.; King, Trude V.V.; Calvin, Wendy M.
1993-01-01
We have developed a digital reflectance spectral library, with management and spectral analysis software. The library includes 498 spectra of 444 samples (some samples include a series of grain sizes) measured from approximately 0.2 to 3.0 um . The spectral resolution (Full Width Half Maximum) of the reflectance data is <= 4 nm in the visible (0.2-0.8 um) and <= 10 nm in the NIR (0.8-2.35 um). All spectra were corrected to absolute reflectance using an NIST Halon standard. Library management software lets users search on parameters (e.g. chemical formulae, chemical analyses, purity of samples, mineral groups, etc.) as well as spectral features. Minerals from borate, carbonate, chloride, element, halide, hydroxide, nitrate, oxide, phosphate, sulfate, sulfide, sulfosalt, and the silicate (cyclosilicate, inosilicate, nesosilicate, phyllosilicate, sorosilicate, and tectosilicate) classes are represented. X-Ray and chemical analyses are tabulated for many of the entries, and all samples have been evaluated for spectral purity. The library also contains end and intermediate members for the olivine, garnet, scapolite, montmorillonite, muscovite, jarosite, and alunite solid-solution series. We have included representative spectra of H2O ice, kerogen, ammonium-bearing minerals, rare-earth oxides, desert varnish coatings, kaolinite crystallinity series, kaolinite-smectite series, zeolite series, and an extensive evaporite series. Because of the importance of vegetation to climate-change studies we have include 17 spectra of tree leaves, bushes, and grasses. The library and software are available as a series of U.S.G.S. Open File reports. PC user software is available to convert the binary data to ascii files (a separate U.S.G.S. open file report). Additionally, a binary data files are on line at the U.S.G.S. in Denver for anonymous ftp to users on the Internet. The library search software enables a user to search on documentation parameters as well as spectral features. The analysis system includes general spectral analysis routines, plotting packages, radiative transfer software for computing intimate mixtures, routines to derive optical constants from reflectance spectra, tools to analyze spectral features, and the capability to access imaging spectrometer data cubes for spectral analysis. Users may build customized libraries (at specific wavelengths and spectral resolution) for their own instruments using the library software. We are currently extending spectral coverage to 150 um. The libraries (original and convolved) will be made available in the future on a CD-ROM.
Subgap time of flight: A spectroscopic study of deep levels in semi-insulating CdTe:Cl
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pousset, J.; Farella, I.; Cola, A., E-mail: adriano.cola@le.imm.cnr.it
2016-03-14
We report on a study of deep levels in semi-insulating CdTe:Cl by means of a time-of-flight spectral approach. By varying the wavelength of a pulsed optical source within the CdTe energy gap, transitions to/from localized levels generate free carriers which are analysed through the induced photocurrent transients. Both acceptor-like centers, related to the A-center, and a midgap level, 0.725 eV from the valence band, have been detected. The midgap level is close to the Fermi level and is possibly a recombination center responsible for the compensation mechanism. When the irradiance is varied, either linear or quadratic dependence of the electron andmore » hole collected charge are observed, depending on the dominant optical transitions. The analysis discloses the potentiality of such a novel approach exploitable in the field of photorefractive materials as well as for deep levels spectroscopy.« less
Arroyo-Reyna, A; Hernandez-Arana, A; Arreguin-Espinosa, R
1994-01-01
Two forms of stem bromelain (EC 3.4.22.4) were isolated from commercial, crude and chromatographically purified preparations of the enzyme by means of gel-filtration and cation-exchange liquid chromatography. These forms possess nearly identical secondary and tertiary structures, as judged from their circular dichroism (c.d.) spectra. The spectral characteristics of stem bromelain suggest that this enzyme belongs to the alpha + beta protein class, as other cysteine proteinases do. In agreement with these results, quantitative estimation of secondary structures yielded amounts similar to those for papain and proteinase omega. However, the bromelain c.d. curve is clearly distinguishable from those reported for papain and proteinase omega, on one hand, and that of chymopapain, on the other. Thus, it is apparent that there are at least three types of c.d. spectra associated with the family of cysteine proteinases. PMID:8198520
NASA Astrophysics Data System (ADS)
Ünaldı, Tevfik; Mızrak, İbrahim; Kadir, Selahattin
2013-12-01
Physicochemical characterisation of natural K-clinoptilolite and heavy-metal (Ag+, Cd2+, Cr3+ and Co3+) forms was accomplished through ion exchange by batch, X-ray diffractometric (XRD), X-ray fluorescence (XRF), infrared-spectral (FT-IR), differential thermal analysis-thermal gravimetric (DTA-TG) and scanning-electron microscopic (SEM) methods. Increasing the normality in the cases of heavy-metal forms resulted in decrease in crystallinity and increases in unit-cell volume, rate of ion exchange, and percentage of ion selectivity. In this study, the order of ion-selectivity percentages (rather than ion selectivity) of heavy-metal forms was determined to be Ag+ > Cd2+ > Cr3+ > Co3+. This finding is consistent with the results of worldwide research on the order of ion selectivity in modified clinoptilolite.
NASA Astrophysics Data System (ADS)
Prabu, Samikannu; Swaminathan, Meenakshisundaram; Sivakumar, Krishnamoorthy; Rajamohan, Rajaram
2015-11-01
The formation through supramolecular interaction of a host-guest inclusion complex of caffeine (CA) with nano-hydrophobic cavity beta-cyclodextrin (β-CD) is achieved by a physical mixture, a kneading method and a co-precipitation method. The formation of the inclusion complex of CA with β-CD in solution state is confirmed by UV-visible spectrophotometer, fluorescence spectrophotometer and time-resolved fluorescence spectrophotometer. The stoichiometry of the inclusion complex is 1:1; the imidazole ring and pyrimidine ring of caffeine is deeply entrapped in the beta-cyclodextrin as confirmed by spectral shifts. The Benesi-Hildebrand plot is used to calculate the binding constant of the inclusion complex of CA with β-CD at room temperature. The Gibbs free energy change of the inclusion complex process is calculated and the process is found to be spontaneous. The thermal stability of the inclusion complex of CA with β-CD is analyzed using differential scanning calorimetry. The crystal structure modification of a solid inclusion complex is confirmed by scanning electron microscopy image analysis. The formation of the inclusion complex of CA with β-CD in the solid phase is also confirmed by FT-IR and XRD. The formation of the inclusion complex between CA and β-CD, as confirmed by molecular docking studies, is in good relationship with the results obtained through different experimental methods.
Kotresh, M G; Inamdar, L S; Shivkumar, M A; Adarsh, K S; Jagatap, B N; Mulimani, B G; Advirao, G M; Inamdar, S R
2017-06-01
In this paper, a systematic investigation of the interaction of bovine serum albumin (BSA) with water-soluble CdTe quantum dots (QDs) of two different sizes capped with carboxylic thiols is presented based on steady-state and time-resolved fluorescence measurements. Efficient Förster resonance energy transfer (FRET) was observed to occur from BSA donor to CdTe acceptor as noted from reduction in the fluorescence of BSA and enhanced fluorescence from CdTe QDs. FRET parameters such as Förster distance, spectral overlap integral, FRET rate constant and efficiency were determined. The quenching of BSA fluorescence in aqueous solution observed in the presence of CdTe QDs infers that fluorescence resonance energy transfer is primarily responsible for the quenching phenomenon. Bimolecular quenching constant (k q ) determined at different temperatures and the time-resolved fluorescence data provide additional evidence for this. The binding stoichiometry and various thermodynamic parameters are evaluated by using the van 't Hoff equation. The analysis of the results suggests that the interaction between BSA and CdTe QDs is entropy driven and hydrophobic forces play a key role in the interaction. Binding of QDs significantly shortened the fluorescence lifetime of BSA which is one of the hallmarks of FRET. The effect of size of the QDs on the FRET parameters are discussed in the light of FRET parameters obtained. Copyright © 2016 John Wiley & Sons, Ltd.
Structural changes at the metal ion binding site during the phosphoglucomutase reaction.
Ray, W J; Post, C B; Liu, Y; Rhyu, G I
1993-01-12
An electron density map of the reactive, Cd2+ form of crystalline phosphoglucomutase from X-ray diffraction studies shows that the enzymic phosphate donates a nonbridging oxygen to the ligand sphere of the bound metal ion, which appears to be tetracoordinate. 31P and 113Cd NMR spectroscopy are used to assess changes in the properties of bound Cd2+ produced by substrate/product and by substrate/product analog inhibitors. The approximately 50 ppm downfield shift of the 113Cd resonance on formation of the complex of dephosphoenzyme and glucose 1,6-bisphosphate is associated with the initial sugar-phosphate binding step and likely involves a change in the geometry of the coordinating ligands. This interpretation is supported by spectral studies involving various complexes of the active Co2+ and Ni(2+)-enzyme. In addition, there is a loss of the 31P-113Cd J coupling that characterizes the monophosphate complexes of the Cd2+ enzyme either during or immediately after the PO3- transfer step that produces the bisphosphate complex, indicating a further change at the metal binding site. The implications of these observations with respect to the PO3- transfer process in the phosphoglucomutase reaction are considered. The apparent plasticity of the ligand sphere of the active site metal ion in this system may allow a single metal ion to act as a chaperone for a nonbridging oxygen during PO3- transfer or to allow a change in metal ion coordination during catalysis. A general NMR line shape/chemical-exchange analysis for evaluating binding in protein-ligand systems when exchange is intermediate to fast on the NMR time scale is described. Its application to the present system involves multiple exchange sites that depend on a single binding rate, thereby adding further constraints to the analysis.
Cat colour vision: one cone process or several?
Daw, N. W.; Pearlman, A. L.
1969-01-01
1. Peripheral mechanisms that might contribute to colour vision in the cat have been investigated by recording from single units in the lateral geniculate and optic tract. Evidence is presented that the input to these cells comes from a single class of cones with a single spectral sensitivity. 2. In cats with pupils dilated a background level of 10-30 cd/m2 was sufficient to saturate the rod system for all units. When the rods were saturated, the spectral sensitivity of all units peaked at 556 nm; this was true both for centre and periphery of the receptive field. The spectral sensitivity curve was slightly narrower than the Dartnall nomogram. It could not be shifted by chromatic adaptation with red, green, blue or yellow backgrounds. 3. In the mesopic range (0·1-10 cd/m2), the threshold could be predicted in terms of two mechanisms, a cone mechanism with spectral sensitivity peaking at 556 nm, and a rod mechanism with spectral sensitivity at 500 nm. The mechanisms were separated and their increment threshold curves measured by testing with one colour against a background of another colour. All units had input from both rods and cones. The changeover from rods to cones occurred at the same level of adaptation in both centre and periphery of the receptive field. Threshold for the cones was between 0·04 and 0·25 cd/m2 with the pupil dilated, for a spot covering the centre of the receptive field. 4. None of the results was found to vary between lateral geniculate and optic tract, with layer in the lateral geniculate, or with distance from area centralis in the visual field. 5. The lack of evidence for more than one cone type suggests that colour discrimination in the cat may be a phenomenon of mesopic vision, based on differences in spectral sensitivity of the rods and a single class of cones. PMID:5767891
Modeling of HgCdTe focal plane array spectral inhomogeneities
NASA Astrophysics Data System (ADS)
Mouzali, Salima; Lefebvre, Sidonie; Rommeluère, Sylvain; Ferrec, Yann; Primot, Jérôme
2015-06-01
Infrared focal plane arrays (IRFPA) are widely used to perform high quality measurements such as spectrum acquisition at high rate, ballistic missile defense, gas detection, and hyperspectral imaging. For these applications, the fixed pattern noise represents one of the major limiting factors of the array performance. This sensor imperfection refers to the nonuniformity between pixels, and is partially caused by disparities of the cut-off wavenumbers. In this work, we focus particularly on mercury cadmium telluride (HgCdTe), which is the most important material of IR cooled detector applications. Among the many advantages of this ternary alloy is the tunability of the bandgap energy with Cadmium composition, as well as the high quantum efficiency. In order to predict and understand spectral inhomogeneities of HgCdTe-based IRFPA, we propose a modeling approach based on the description of optical phenomena inside the pixels. The model considers the p-n junctions as a unique absorbent bulk layer, and derives the sensitivity of the global structure to both Cadmium composition and HgCdTe layer thickness. For this purpose, HgCdTe optical and material properties were necessary to be known at low temperature (80K), in our operating conditions. We therefore achieved the calculation of the real part of the refractive index using subtracti
NASA Astrophysics Data System (ADS)
Dinelli, B. M.; Fabiano, F.; Adriani, A.; Altieri, F.; Moriconi, M. L.; Mura, A.; Sindoni, G.; Filacchione, G.; Tosi, F.; Migliorini, A.; Grassi, D.; Piccioni, G.; Noschese, R.; Cicchetti, A.; Bolton, S. J.; Connerney, J. E. P.; Atreya, S. K.; Bagenal, F.; Gladstone, G. R.; Hansen, C. J.; Kurth, W. S.; Levin, S. M.; Mauk, B. H.; McComas, D. J.; Gèrard, J.-C.; Turrini, D.; Stefani, S.; Amoroso, M.; Olivieri, A.
2017-05-01
During the first orbit around Jupiter of the NASA/Juno mission, the Jovian Auroral Infrared Mapper (JIRAM) instrument observed the auroral regions with a large number of measurements. The measured spectra show both the emission of the H3+ ion and of methane in the 3-4 μm spectral region. In this paper we describe the analysis method developed to retrieve temperature and column density (CD) of the H3+ ion from JIRAM spectra in the northern auroral region. The high spatial resolution of JIRAM shows an asymmetric aurora, with CD and temperature ovals not superimposed and not exactly located where models and previous observations suggested. On the main oval averaged H3+ CDs span between 1.8 × 1012 cm-2 and 2.8 × 1012 cm-2, while the retrieved temperatures show values between 800 and 950 K. JIRAM indicates a complex relationship among H3+ CDs and temperatures on the Jupiter northern aurora.
NASA Astrophysics Data System (ADS)
Guesmi, Latifa; Menif, Mourad
2015-09-01
Optical performance monitoring (OPM) becomes an inviting topic in high speed optical communication networks. In this paper, a novel technique of OPM based on a new elaborated computation approach of singular spectrum analysis (SSA) for time series prediction is presented. Indeed, various optical impairments among chromatic dispersion (CD), polarization mode dispersion (PMD) and amplified spontaneous emission (ASE) noise are a major factors limiting quality of transmission data in the systems with data rates lager than 40 Gbit/s. This technique proposed an independent and simultaneous multi-impairments monitoring, where we used SSA of time series analysis and forecasting. It has proven their usefulness in the temporal analysis of short and noisy time series in several fields, that it is based on the singular value decomposition (SVD). Also, advanced optical modulation formats (100 Gbit/s non-return-to zero dual-polarization quadrature phase shift keying (NRZ-DP-QPSK) and 160 Gbit/s DP-16 quadrature amplitude modulation (DP-16QAM)) offering high spectral efficiencies have been successfully employed by analyzing their asynchronously sampled amplitude. The simulated results proved that our method is efficient on CD, first-order PMD, Q-factor and OSNR monitoring, which enabled large monitoring ranges, the CD in the range of 170-1700 ps/nm.Km and 170-1110 ps/nm.Km for 100 Gbit/s NRZ-DP-QPSK and 160 Gbit/s DP-16QAM respectively, and also the DGD up to 20 ps is monitored. We could accurately monitor the OSNR in the range of 10-40 dB with monitoring error remains less than 1 dB in the presence of large accumulated CD.
Rao, Monica R P; Chaudhari, Jagruti; Trotta, Francesco; Caldera, Fabrizio
2018-06-04
Rilpivrine is BCS class II drug used for treatment of HIV infection. The drug has low aqueous solubility (0.0166 mg/ml) and dissolution rate leading to low bioavailability (32%). Aim of this work was to enhance solubility and dissolution of rilpivirine using beta-cyclodextrin-based nanosponges. These nanosponges are biocompatible nanoporous particles having high loading capacity to form supramolecular inclusion and non-inclusion complexes with hydrophilic and lipophilic drugs for solubility enhancement. Beta-cyclodextrin was crosslinked with carbonyl diimidazole and pyromellitic dianhydride to prepare nanosponges. The nanosponges were loaded with rilpivirine by solvent evaporation method. Binary and ternary complexes of drug with β-CD, HP-β-CD, nanosponges, and tocopherol polyethylene glycol succinate were prepared and characterized by phase solubility, saturation solubility in different media, in vitro dissolution, and in vivo pharmacokinetics. Spectral analysis by Fourier transform infrared spectroscopy, powder X-ray diffraction, and differential scanning calorimetry was performed. Results obtained from spectral characterization confirmed inclusion complexation. Phase solubility studies indicated stable complex formation. Saturation solubility was found to be 10-13-folds higher with ternary complexes in distilled water and 12-14-fold higher in 0.1 N HCl. Solubility enhancement was evident in biorelevant media. Molecular modeling studies revealed possible mode of entrapment of rilpivirine within β-CD cavities. A 3-fold increase in dissolution with ternary complexes was observed. Animal studies revealed nearly 2-fold increase in oral bioavailability of rilpivirine. It was inferred that electronic interactions, hydrogen bonding, and van der Waals forces are involved in the supramolecular interactions.
Spectrum-per-Pixel Cathodoluminescence Imaging of CdTe Thin-Film Bevels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moseley, John; Al-Jassim, Mowafak M.; Burst, James
2016-11-21
We conduct T=6 K cathodoluminescence (CL) spectrum imaging with a nano-scale electron beam on beveled surfaces of CdTe thin-films at different critical stages of standard CdTe device fabrication. The through-thickness total CL intensity profiles are consistent with a reduction in grain boundary recombination due to the CdCl2 treatment. Color-coded maps of the low-temperature luminescence transition energies reveal that CdTe thin films have remarkably non-uniform opto-electronic properties, which depend strongly on sample processing history. The grain-to-grain S content in the interdiffused CdTe/CdS region is estimated from a sample size of thirty-five grains, and the S content in adjacent grains varies significantlymore » in CdCl2-treated samples. A low-temperature luminescence model is developed to interpret spectral behavior at grain boundaries and grain interiors.« less
NASA Astrophysics Data System (ADS)
Bellotti, Enrico; Wen, Hanqing; Dominici, Stefano; Glasmann, Andreu L.
2017-02-01
HgCdTe has been the material of choice for MWIR, and LWIR infrared sensing due to its highly tunable band gap and favorable material properties. However, HgCdTe growth and processing for the ESWIR spectral region is less developed, so alternative materials are actively researched. It is important to compare the fundamental limitations of each material to determine which offers optimal device performance. In this article, we investigate the intrinsic recombination mechanisms of ESWIR materials—InGaAs, GeSn, and HgCdTe—with cutoff wavelength near 2.5μm, and MWIR with cutoff of 5μm. First, using an empirical pseudo-potential model, we calculate the full band structure of each alloy using the virtual crystal approximation, modified to include disorder effects and spin-orbit coupling. We then evaluate the Auger and radiative recombination rates using a Green's function based model, applied to the full material band structure, yielding intrinsic carrier lifetimes for each given temperature, carrier injection, doping density, and cutoff wavelength. For example, we show that ESWIR HgCdTe has longer carrier lifetimes than InGaAs when strained or relaxed near room temperature, which is advantageous for high operating temperature photodetectors. We perform similar analyses for varying composition GeSn by comparing the calculated lifetimes with InGaAs and HgCdTe. Finally, we compare HgCdTe, InAsSb and GeSn with a cutoff in the MWIR spectral band.
Fornasaro, Stefano; Vicario, Annalisa; De Leo, Luigina; Bonifacio, Alois; Not, Tarcisio; Sergo, Valter
2018-05-14
Raman hyperspectral imaging is an emerging practice in biological and biomedical research for label free analysis of tissues and cells. Using this method, both spatial distribution and spectral information of analyzed samples can be obtained. The current study reports the first Raman microspectroscopic characterisation of colon tissues from patients with Coeliac Disease (CD). The aim was to assess if Raman imaging coupled with hyperspectral multivariate image analysis is capable of detecting the alterations in the biochemical composition of intestinal tissues associated with CD. The analytical approach was based on a multi-step methodology: duodenal biopsies from healthy and coeliac patients were measured and processed with Multivariate Curve Resolution Alternating Least Squares (MCR-ALS). Based on the distribution maps and the pure spectra of the image constituents obtained from MCR-ALS, interesting biochemical differences between healthy and coeliac patients has been derived. Noticeably, a reduced distribution of complex lipids in the pericryptic space, and a different distribution and abundance of proteins rich in beta-sheet structures was found in CD patients. The output of the MCR-ALS analysis was then used as a starting point for two clustering algorithms (k-means clustering and hierarchical clustering methods). Both methods converged with similar results providing precise segmentation over multiple Raman images of studied tissues.
SERS-fluorescence joint spectral encoded magnetic nanoprobes for multiplex cancer cell separation.
Wang, Zhuyuan; Zong, Shenfei; Chen, Hui; Wang, Chunlei; Xu, Shuhong; Cui, Yiping
2014-11-01
A new kind of cancer cell separation method is demonstrated, using surface-enhanced Raman scattering (SERS) and fluorescence dual-encoded magnetic nanoprobes. The designed nanoprobes can realize SERS-fluorescence joint spectral encoding (SFJSE) and greatly improve the multiplexing ability. The nanoprobes have four main components, that is, the magnetic core, SERS generator, fluorescent agent, and targeting antibody. These components are assembled with a multi-layered structure to form the nanoprobes. Specifically, silica-coated magnetic nanobeads (MBs) are used as the inner core. Au core-Ag shell nanorods (Au@Ag NRs) are employed as the SERS generators and attached on the silica-coated MBs. After burying these Au@Ag NRs with another silica layer, CdTe quantum dots (QDs), that is, the fluorescent agent, are anchored onto the silica layer. Finally, antibodies are covalently linked to CdTe QDs. SFJSE is fulfilled by using different Raman molecules and QDs with different emission wavelengths. By utilizing four human cancer cell lines and one normal cell line as the model cells, the nanoprobes can specifically and simultaneously separate target cancer cells from the normal ones. This SFJSE-based method greatly facilitates the multiplex, rapid, and accurate cancer cell separation, and has a prosperous potential in high-throughput analysis and cancer diagnosis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Chen, Cong; Cheng, Yu; Jin, Junjie; Dai, Qilin; Song, Hongwei
2016-10-15
Co-sensitization by using two or more sensitizers with complementary absorption spectra to expand the spectral response range is an effective approach to enhance device performance of quantum dot sensitized solar cells (QDSSCs). To improve the light-harvesting in the visible/near-infrared (NIR) region, organic dye zinc phthalocyanine (ZnPc) was combined with CdS/CdSe quantum dots (QDs) for co-sensitized solar cells based on ZnO inverse opals (IOs) as photoanode. The resulting co-sensitized device shows an efficient panchromatic spectral response feature to ∼750nm and presents an overall conversion efficiency of 4.01%, which is superior to that of the individual ZnPc-sensitized solar cells and CdS/CdSe-sensitized solar cells. Meanwhile, an Au nanoparticles/graphene oxide (Au NPs/GO) composite layer was successfully prepared to modify Cu2S counter electrode for the co-sensitized solar cells. Reducing the carrier recombination process by GO and catalytic process of Au NPs leads to increased power conversion efficiency(PCE) from 4.01 to 4.60% and sustainable stability remains ∼85% of its original value after 60min light exposure. In this paper, introduction of the organic dyes as co-sensitizer and Au NPs/GO as counter electrode modified layer has been proved to be an effective route to improve the performance of QDSSCs. Copyright © 2016 Elsevier Inc. All rights reserved.
Jeong, Ho-Jung; Kim, Ye-Chan; Lee, Soo Kyung; Jeong, Yonkil; Song, Jin-Won; Yun, Ju-Hyung; Jang, Jae-Hyung
2017-08-02
Conventional Cu(In 1-x ,Ga x )Se 2 (CIGS) solar cells exhibit poor spectral response due to parasitic light absorption in the window and buffer layers at the short wavelength range between 300 and 520 nm. In this study, the CdSe/CdZnS core/shell quantum dots (QDs) acting as a luminescent down-shifting (LDS) layer were inserted between the MgF 2 antireflection coating and the window layer of the CIGS solar cell to improve light harvesting in the short wavelength range. The LDS layer absorbs photons in the short wavelength range and re-emits photons in the 609 nm range, which are transmitted through the window and buffer layer and absorbed in the CIGS layer. The average external quantum efficiency in the parasitic light absorption region (300-520 nm) was enhanced by 51%. The resulting short circuit current density of 34.04 mA/cm 2 and power conversion efficiency of 14.29% of the CIGS solar cell with the CdSe/CdZnS QDs were improved by 4.35 and 3.85%, respectively, compared with those of the conventional solar cells without QDs.
Molecular differentiation of Leishmania protozoarium using CdS quantum dots as biolabels
NASA Astrophysics Data System (ADS)
Santos, Beate S.; de Farias, Patrícia M. A.; de Menezes, Frederico D.; Mariano, Erick L.; de C. Ferreira, Ricardo; Giorgio, Selma; Bosetto, Maira C.; Ayres, Diana C.; Lima, Paulo M.; Fontes, Adriana; de Thomas, André A.; Cesar, Carlos L.
2006-02-01
In this work we applied core-shell CdS/Cd(OH)2 quantum dots (QDs) as fluorescent labels in the Leishmania amazonensis protozoarium. The nanocrystals (8-9 nm) are obtained via colloidal synthesis in aqueous medium, with final pH=7 using sodium polyphosphate as the stabilizing agent. The surface of the particles is passivated with a cadmium hydroxide shell and the particle surface is functionalized with glutaraldehyde. The functionalized and non-functionalized particles were conjugated to Leishmania organisms in the promastigote form. The marked live organisms were visualized using confocal microscopy. The systems exhibit a differentiation of the emission color for the functionalized and non-functionalized particles suggesting different chemical interactions with the promastigote moieties. Two photon emision spectra (λ exc=795nm) were obtained for the promastigotes labeled with the functionalized QDs showing a significant spectral change compared to the original QDs suspension. These spectral changes are discussed in terms of the possible energy deactivation processes.
NASA Astrophysics Data System (ADS)
Pardo-Iguzquiza, Eulogio; Rodríguez-Tovar, Francisco J.
2011-12-01
One important handicap when working with stratigraphic sequences is the discontinuous character of the sedimentary record, especially relevant in cyclostratigraphic analysis. Uneven palaeoclimatic/palaeoceanographic time series are common, their cyclostratigraphic analysis being comparatively difficult because most spectral methodologies are appropriate only when working with even sampling. As a means to solve this problem, a program for calculating the smoothed Lomb-Scargle periodogram and cross-periodogram, which additionally evaluates the statistical confidence of the estimated power spectrum through a Monte Carlo procedure (the permutation test), has been developed. The spectral analysis of a short uneven time series calls for assessment of the statistical significance of the spectral peaks, since a periodogram can always be calculated but the main challenge resides in identifying true spectral features. To demonstrate the effectiveness of this program, two case studies are presented: the one deals with synthetic data and the other with paleoceanographic/palaeoclimatic proxies. On a simulated time series of 500 data, two uneven time series (with 100 and 25 data) were generated by selecting data at random. Comparative analysis between the power spectra from the simulated series and from the two uneven time series demonstrates the usefulness of the smoothed Lomb-Scargle periodogram for uneven sequences, making it possible to distinguish between statistically significant and spurious spectral peaks. Fragmentary time series of Cd/Ca ratios and δ18O from core AII107-131 of SPECMAP were analysed as a real case study. The efficiency of the direct and cross Lomb-Scargle periodogram in recognizing Milankovitch and sub-Milankovitch signals related to palaeoclimatic/palaeoceanographic changes is demonstrated. As implemented, the Lomb-Scargle periodogram may be applied to any palaeoclimatic/palaeoceanographic proxies, including those usually recovered from contourites, and it holds special interest in the context of centennial- to millennial-scale climatic changes affecting contouritic currents.
Sundararajan, M L; Jeyakumar, T; Anandakumaran, J; Karpanai Selvan, B
2014-10-15
Metal complexes of Zn(II), Cd(II), Ni(II), Cu(II), Fe(III), Co(II), Mn(II) Hg(II), and Ag(I) have been synthesized from Schiff base ligand, prepared by the condensation of 3,4-(methylenedioxy)aniline and 5-bromo salicylaldehyde. All the compounds have been characterized by using elemental analysis, molar conductance, FT-IR, UV-Vis, (1)H NMR, (13)C NMR, mass spectra, powder XRD and thermal analysis (TG/DTA) technique. The elemental analysis suggests the stoichiometry to be 1:1 (metal:ligand). The FT-IR, (1)H NMR, (13)C NMR and UV-Vis spectral data suggest that the ligand coordinate to the metal atom by imino nitrogen and phenolic oxygen as bidentate manner. Mass spectral data further support the molecular mass of the compounds and their structure. Powder XRD indicates the crystalline state and morphology of the ligand and its metal complexes. The thermal behaviors of the complexes prove the presence of lattice as well as coordinated water molecules in the complexes. Melting point supports the thermal stability of all the compounds. The in vitro antimicrobial effects of the synthesized compounds were tested against five bacterial and three fungal species by well diffusion method. Antioxidant activities have also been performed for all the compounds. Metal complexes show more biological activity than the Schiff base. Copyright © 2014 Elsevier B.V. All rights reserved.
Arvinte, Tudor; Bui, Tam T T; Dahab, Ali A; Demeule, Barthélemy; Drake, Alex F; Elhag, Dhia; King, Peter
2004-09-01
Circular dichroism (CD) is an important spectroscopic technique for monitoring chirality and biological macromolecule conformation. However, during a CD measurement, absorbance, light scattering/turbidity, and fluorescence can also be detected. The simultaneous measurement of these different spectral features for a single sample is the basis of a multi-mode optical spectrometer. This allows time-efficient gathering of complementary information and provides a scheme to ensure that CD measurements are reliable. Aspects of circular polarization differential light scattering, pH, and temperature variation of a protein (antibody) solution are described. A procedure to help ensure that CD measurements are reliable is described.
Aldawsari, Abdullah; Hameed, B. H.; Alqadami, Ayoub Abdullah; Siddiqui, Masoom Raza; Alothman, Zeid Abdullah; Ahmed, A. Yacine Badjah Hadj
2017-01-01
A substantive approach converting waste date pits to mercerized mesoporous date pit activated carbon (DPAC) and utilizing it in the removal of Cd(II), Cu(II), Pb(II), and Zn(II) was reported. In general, rapid heavy metals adsorption kinetics for Co range: 25–100 mg/L was observed, accomplishing 77–97% adsorption within 15 min, finally, attaining equilibrium in 360 min. Linear and non-linear isotherm studies revealed Langmuir model applicability for Cd(II) and Pb(II) adsorption, while Freundlich model was fitted to Zn(II) and Cu(II) adsorption. Maximum monolayer adsorption capacities (qm) for Cd(II), Pb(II), Cu(II), and Zn(II) obtained by non-linear isotherm model at 298 K were 212.1, 133.5, 194.4, and 111 mg/g, respectively. Kinetics modeling parameters showed the applicability of pseudo-second-order model. The activation energy (Ea) magnitude revealed physical nature of adsorption. Maximum elution of Cu(II) (81.6%), Zn(II) (70.1%), Pb(II) (96%), and Cd(II) (78.2%) were observed with 0.1 M HCl. Thermogravimetric analysis of DPAC showed a total weight loss (in two-stages) of 28.3%. Infra-red spectral analysis showed the presence of carboxyl and hydroxyl groups over DPAC surface. The peaks at 820, 825, 845 and 885 cm-1 attributed to Zn–O, Pb–O, Cd–O, and Cu–O appeared on heavy metals saturated DPAC, confirmed their binding on DPAC during the adsorption. PMID:28910368
A polychromatic adaption of the Beer-Lambert model for spectral decomposition
NASA Astrophysics Data System (ADS)
Sellerer, Thorsten; Ehn, Sebastian; Mechlem, Korbinian; Pfeiffer, Franz; Herzen, Julia; Noël, Peter B.
2017-03-01
We present a semi-empirical forward-model for spectral photon-counting CT which is fully compatible with state-of-the-art maximum-likelihood estimators (MLE) for basis material line integrals. The model relies on a minimum calibration effort to make the method applicable in routine clinical set-ups with the need for periodic re-calibration. In this work we present an experimental verifcation of our proposed method. The proposed method uses an adapted Beer-Lambert model, describing the energy dependent attenuation of a polychromatic x-ray spectrum using additional exponential terms. In an experimental dual-energy photon-counting CT setup based on a CdTe detector, the model demonstrates an accurate prediction of the registered counts for an attenuated polychromatic spectrum. Thereby deviations between model and measurement data lie within the Poisson statistical limit of the performed acquisitions, providing an effectively unbiased forward-model. The experimental data also shows that the model is capable of handling possible spectral distortions introduced by the photon-counting detector and CdTe sensor. The simplicity and high accuracy of the proposed model provides a viable forward-model for MLE-based spectral decomposition methods without the need of costly and time-consuming characterization of the system response.
Research on the electrical characteristics of the Pt/CdS Schottky diode
NASA Astrophysics Data System (ADS)
Ding, Jia-xin; Zhang, Xiang-feng; Yao, Guansheng
2013-08-01
With the development of technology, the demand for semiconductor ultraviolet detector is increasing day by day. Compared with the traditional infrared detector in missile guidance, ultraviolet/infrared dual-color detection can significantly improve the anti-interference ability of the missile. According to the need of missile guidance and other areas of the application of ultraviolet detector, the paper introduces a manufacture of the CdS Schottky barrier ultraviolet detector. By using the radio frequency magnetron sputtering technology, a Pt thin film layer is sputtered on CdS basement to form a Schottky contact firstly. Then the indium ohmic contact electrode is fabricated by thermal evaporation method, and eventually a Pt/CdS/In Schottky diode is formed. The I-V characteristic of the device was tested at room temperature, its zero bias current and open circuit voltage is -0.578nA and 130mV, respectively. Test results show that the the Schottky contact has been formed between Pt and CdS. The device has good rectifying characteristics. According to the thermionic emission theory, the I-V curve fitting analysis of the device was studied under the condition of small voltage. The ideality factor and Schottky barrier height is 1.89 and 0.61eV, respectively. The normalized spectral responsivity at zero bias has been tested. The device has peak responsivity at 500nm, and it cutoff at 510nm.
2015-01-01
Here, we report improved solubility and enhanced colonic delivery of reduced bromonoscapine (Red-Br-Nos), a cyclic ether brominated analogue of noscapine, upon encapsulation of its cyclodextrin (CD) complexes in bioresponsive guar gum microspheres (GGM). Phase–solubility analysis suggested that Red-Br-Nos complexed with β-CD and methyl-β-CD in a 1:1 stoichiometry, with a stability constant (Kc) of 2.29 × 103 M–1 and 4.27 × 103 M–1. Fourier transforms infrared spectroscopy indicated entrance of an O–CH2 or OCH3–C6H4–OCH3 moiety of Red-Br-Nos in the β-CD or methyl-β-CD cavity. Furthermore, the cage complex of Red-Br-Nos with β-CD and methyl-β-CD was validated by several spectral techniques. Rotating frame Overhauser enhancement spectroscopy revealed that the Ha proton of the OCH3–C6H4–OCH3 moiety was closer to the H5 proton of β-CD and the H3 proton of the methyl-β-CD cavity. The solubility of Red-Br-Nos in phosphate buffer saline (PBS, pH ∼ 7.4) was improved by ∼10.7-fold and ∼21.2-fold when mixed with β-CD and methyl-β-CD, respectively. This increase in solubility led to a favorable decline in the IC50 by ∼2-fold and ∼3-fold for Red-Br-Nos−β-CD-GGM and Red-Br-Nos–methyl-β-CD-GGM formulations respectively, compared to free Red-Br-Nos−β-CD and Red-Br-Nos–methyl-β-CD in human colon HT-29 cells. GGM-bearing drug complex formulations were found to be highly cytotoxic to the HT-29 cell line and further effective with simultaneous continuous release of Red-Br-Nos from microspheres. This is the first study to showing the preparation of drug-complex loaded GGMS for colon delivery of Red-Br-Nos that warrants preclinical assessment for the effective management of colon cancer. PMID:25350222
Automatic cytometric device using multiple wavelength excitations
NASA Astrophysics Data System (ADS)
Rongeat, Nelly; Ledroit, Sylvain; Chauvet, Laurence; Cremien, Didier; Urankar, Alexandra; Couderc, Vincent; Nérin, Philippe
2011-05-01
Precise identification of eosinophils, basophils, and specific subpopulations of blood cells (B lymphocytes) in an unconventional automatic hematology analyzer is demonstrated. Our specific apparatus mixes two excitation radiations by means of an acousto-optics tunable filter to properly control fluorescence emission of phycoerythrin cyanin 5 (PC5) conjugated to antibodies (anti-CD20 or anti-CRTH2) and Thiazole Orange. This way our analyzer combining techniques of hematology analysis and flow cytometry based on multiple fluorescence detection, drastically improves the signal to noise ratio and decreases the spectral overlaps impact coming from multiple fluorescence emissions.
On the response of alloyed ZnCdSeS quantum dot films
NASA Astrophysics Data System (ADS)
Valais, I.; Michail, C.; Fountzoula, C.; Tseles, D.; Yannakopoulos, P.; Nikolopoulos, D.; Bakas, A.; Fountos, G.; Saatsakis, G.; Sianoudis, I.; Kandarakis, I.; Panayiotakis, G.
The aim of this work was to prepare composite ZnCdSeS quantum dot (QD) flexible films and to examine their optical properties under ultraviolet excitation. PMMA/QD ZnCdSeS composite films, with emission covering the visual spectrum (480-630 nm) were prepared with concentrations 10 mg/mL and 20 mg/mL by homogenously diluting dry powder QD samples in toluene and subsequently mixing with a PMMA/MMA polymer solution to the final ZnCdSeS/Toluene mixture. Scanning electron microscopy (SEM) images of the produced films were obtained. The ZnCdSeS films were excited by ultraviolet light of varying intensities and the spectral matching with various optical detectors was estimated.
NASA Astrophysics Data System (ADS)
El-Megharbel, Samy M.; Hamza, Reham Z.; Refat, Moamen S.
2014-10-01
Keeping in view that some metal complexes are found to be more potent than their parent drugs, therefore, our present paper aimed to synthesized Cd(II), Hg(II) and Pb(II) complexes of paracetamol (Para) anti-inflammatory drug. Paracetamol complexes with general formula [M(Para)2(H2O)2]·nH2O have been synthesized and characterized on the basis of elemental analysis, conductivity, IR and thermal (TG/DTG), 1H NMR, electronic spectral studies. The conductivity data of these complexes have non-electrolytic nature. Comparative antimicrobial (bacteria and fungi) behaviors and molecular weights of paracetamol with their complexes have been studied. In vivo the antihepatotoxicity effect and some liver function parameters levels (serum total protein, ALT, AST, and LDH) were measured. Hematological parameters and liver antioxidant capacities of both Para and their complexes were performed. The Cd2+ + Para complex was recorded amelioration of antioxidant capacities in liver homogenates compared to other Para complexes treated groups.
2013-09-01
is very compatible to growth of mercury cadmium telluride (HgCdTe or MCT) on its surface. HgCdTe is the IR sensitive material. However, CdZnTe is...in Indiana which is one of the few test ranges in the developed world where battlefield smokes and live artillery fire could be 41 F. Shields, NV...spectral region of E&M spectrum) I2 – Image Intensification JIEDDO – Joint IED Defeat Office JPG – Jefferson Proving Ground, Indiana . JPO – Joint
Zincblende to Wurtzite phase shift of CdSe thin films prepared by electrochemical deposition
NASA Astrophysics Data System (ADS)
Bai, Rekha; Chaudhary, Sujeet; Pandya, Dinesh K.
2018-04-01
Cadmium selenide (CdSe) nanostructured thin films have been deposited on conducting glass substrates by potentiostatic electrochemical deposition (ECD) technique. The effect of electrolyte bath pH on the structural, morphological and optical properties of CdSe films has been investigated. Crystal structure of these films is characterized by X-ray diffraction and Raman spectroscopy which reveal polycrystalline nature of CdSe films exhibiting phase shift from zincblende to wurtzite structure with increase in bath pH. Optical studies reveal that the CdSe thin films have good absorbance in visible spectral region and they possess direct optical band gap which increases from 1.68 to 1.97 eV with increase in bath pH. The results suggest CdSe is an efficient absorber material for next generation solar cells.
Complexation of morin with three kinds of cyclodextrin. A thermodynamic and reactivity study
NASA Astrophysics Data System (ADS)
Jullian, Carolina; Orosteguis, Teresita; Pérez-Cruz, Fernanda; Sánchez, Paulina; Mendizabal, Fernando; Olea-Azar, Claudio
2008-11-01
Properties of inclusion complexes between morin (M) and β-cyclodextrin (βCD), 2-hydroxypropyl-β-cyclodextrin (HPβCD) and Heptakis (2,6- O-di methyl) β-cyclodextrin (DMβCD) such as aqueous solubility and the association constants of this complex have been determined. The water solubility of morin was increased by inclusion with cyclodextrins. The phase-solubility diagrams drawn from UV spectral measurements are of the A L-type. Also ORAC FL studies were done. An increase in the antioxidant reactivity is observed when morin form inclusion complex with the three cyclodextrin studied. Finally, thermodynamics studies of cyclodextrin complexes indicated that for DMβCD the inclusion is primarily enthalpy-driven process meanwhile βCD and HPβCD are entropy-driven processes. This is corroborated by the different inclusion geometries obtained by 2D-NMR.
NASA Technical Reports Server (NTRS)
Ando, K.
1982-01-01
A substantial technology base of solid state pushbroom sensors exists and is in the process of further evolution at both GSFC and JPL. Technologies being developed relate to short wave infrared (SWIR) detector arrays; HgCdTe hybrid detector arrays; InSb linear and area arrays; passive coolers; spectral beam splitters; the deposition of spectral filters on detector arrays; and the functional design of the shuttle/space platform imaging spectrometer (SIS) system. Spatial and spectral characteristics of field, aircraft and space multispectral sensors are summaried. The status, field of view, and resolution of foreign land observing systems are included.
Cytotoxic prenylated flavones from the stem and root bark of Daphne giraldii.
Sun, Qian; Wang, Di; Li, Fei-Fei; Yao, Guo-Dong; Li, Xue; Li, Ling-Zhi; Huang, Xiao-Xiao; Song, Shao-Jiang
2016-08-15
Three new prenylated flavones (1-3), along with three known analogues (4-6), were isolated from the stem and root bark of Daphne giraldii. Their structures were determined by comprehensive NMR and HRESIMS spectroscopic data analyses. The absolute configurations of compounds 2 and 3 were assigned by optical rotation comparison, CD and [Rh2(OCOCF3)4]-induced CD spectral methods. The in vitro cytotoxicity experiments carried out involving five cancer cell lines (U251, A549, HepG2, MCF-7 and Bcap37) showed that 2 markedly inhibited the proliferation of all tested cells with IC50 values ranging from 4.26 to 20.82μM. The preliminary structure-activity relationships of these flavones are discussed. In addition, compound 2 was found to effectively induce apoptosis in HepG2 cells according to a flow cytometry analysis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Classification of Complex Sounds.
1992-10-31
spectral weights may be useful in developing signal enhancement techniques based on psychological aspects of the listener (providing a complement to...Journals) Green, D.M., and Berg, B.G. (1991). Spectral weights and the profile bowl. Quarterly Journal of Experimental Psychology , 43A, 449-458. Dai, H...Macmillan and C.D. Creelman . Cambridge/NY: Cambridge Universi- ty Press, 1991.) J. Math. Psych., in press. Training Currently, there are two graduate
Dental hard tissue ablation using mid-infrared tunable nanosecond pulsed Cr:CdSe laser.
Lin, Taichen; Aoki, Akira; Saito, Norihito; Yumoto, Masaki; Nakajima, Sadahiro; Nagasaka, Keigo; Ichinose, Shizuko; Mizutani, Koji; Wada, Satoshi; Izumi, Yuichi
2016-12-01
Mid-infrared erbium: yttrium-aluminum-garnet (Er:YAG) and erbium, chromium: yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers (2.94- and 2.78-μm, respectively) are utilized for effective dental hard tissue treatment because of their high absorption in water, hydroxide ion, or both. Recently, a mid-infrared tunable, nanosecond pulsed, all-solid-state chromium-doped: cadmium-selenide (Cr:CdSe) laser system was developed, which enables laser oscillation in the broad spectral range around 2.9 μm. The purpose of this study was to evaluate the ablation of dental hard tissue by the nanosecond pulsed Cr:CdSe laser at a wavelength range of 2.76-3.00 μm. Enamel, dentin, and cementum tissue were irradiated at a spot or line at a fluence of 0-11.20 J/cm 2 /pulse (energy output: 0-2.00 mJ/pulse) with a repetition rate of 10 Hz and beam diameter of ∼150 μm on the target (pulse width ∼250 ns). After irradiation, morphological changes, ablation threshold, depth, and efficiency, and thickness of the structurally and thermally affected layer of irradiated surfaces were analyzed using stereomicroscopy, scanning electron microscopy (SEM), and light microscopy of non-decalcified histological sections. The nanosecond pulsed irradiation without water spray effectively ablated dental hard tissue with no visible thermal damage such as carbonization. The SEM analysis revealed characteristic micro-irregularities without major melting and cracks in the lased tissue. The ablation threshold of dentin was the lowest at 2.76 μm and the highest at 3.00 μm. The histological analysis revealed minimal thermal and structural changes ∼20 μm wide on the irradiated dentin surfaces with no significant differences between wavelengths. The efficiency of dentin ablation gradually increased from 3.00 to 2.76 μm, at which point the highest ablation efficiency was observed. The nanosecond pulsed Cr:CdSe laser demonstrated an effective ablation ability of hard dental tissues, which was remarkably wavelength-dependent on dentin at the spectral range of 2.76-3.00 μm. These results demonstrate the potential feasibility of the use of pulsed Cr:CdSe laser as a novel laser system for dental treatment. Lasers Surg. Med. 48:965-977, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Advances in all-sputtered CdTe solar cells on flexible substrates
NASA Astrophysics Data System (ADS)
Wieland, Kristopher; Mahabaduge, Hasitha; Vasko, Anthony; Compaan, Alvin
2010-03-01
The University of Toledo II-VI semiconductor group has developed magnetron sputtering (MS) for the deposition of thin films of CdS, CdTe, and related materials for photovoltaic applications. On glass superstrates, we have reached air mass 1.5 efficiencies of 14%.[1] Recently we have studied the use of MS for the fabrication of thin-film CdS/CdTe cells on flexible polyimide superstrates. This takes advantage of the high film quality that can be achieved at substrate temperatures below 300 C when RF MS is used. Our recent CdS/CdTe solar cells have reached 10.5% on flexible polyimide substrates. [2] This all-sputtered cell (except for back contact) has a structure of polyimide/ZnO:Al/ZnO/CdS/CdTe/Cu/Au. The physics of this device will be discussed through the use of spectral quantum efficiency and current-voltage measurements as a function of CdTe layer thickness. Pathways toward further increases in device efficiencies will also be discussed. [1] Appl. Phys. Lett. 85, 684 (2004) [2] Phys. Stat. Sol. (B) 241, No. 3, 779--782 (2004)
Fermi Large Area Telescope Observations Of Misaligned Active Galactic Nuclei
Abdo, A. A.
2010-08-13
Analysis is presented for 15 months of data taken with the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope for 11 non-blazar active galactic nuclei (AGNs), including seven FRI radio galaxies and four FRII radio sources consisting of two FRII radio galaxies and two steep spectrum radio quasars. The broad line FRI radio galaxy 3C 120 is reported here as a γ-ray source for the first time. The analysis is based on directional associations of LAT sources with radio sources in the 3CR, 3CRR, and MS4 (collectively referred to as 3C-MS) catalogs. Seven of the eleven LAT sourcesmore » associated with 3C-MS radio sources have spectral indices larger than 2.3 and, except for the FRI radio galaxy NGC 1275 that shows possible spectral curvature, are well described by a power law. No evidence for time variability is found for any sources other than NGC 1275. The γ-ray luminosities of FRI radio galaxies are significantly smaller than those of the BL Lac objects detected by the LAT, whereas the γ-ray luminosities of the FRII sources are quite similar to those of FSRQs, which could reflect different beaming factors for the γ-ray emission. A core dominance (CD) study of the 3CRR sample indicates that sources closer to the jet axis are preferentially detected with the Fermi LAT, insofar as the γ-ray-detected misaligned AGNs have larger CD at a given average radio flux. The results are discussed in view of the AGN unification scenario.« less
NASA Astrophysics Data System (ADS)
Ramesh, V.; Shihabuddeen Syed, A.; Jagannathan, K.; Rajarajan, K.
2013-05-01
Single crystal of bis mercury ferric chloride tetra thiocyanate [Hg2FeCl3(SCN)4; (MFCTC)] was grown from ethanol-water (3:1) mixed solvent using slow evaporation solvent technique (SEST) for the first time. The cell parameters of the grown crystal were confirmed by single crystal XRD. The coordination of transition metal ions with the SCN ligand is well-identified using FT-IR spectral analysis. The chemical composition of MFCTC was confirmed using CHNS elemental test. The ESR spectral profile of MFCTC was recorded from 298 K to 110 K, which strongly suggests the incorporation of Fe3+ ion and its environment with respect to SCN ligand. The HPLC chromatogram of MFCTC highlights the purity of the compound. The UV-Vis-NIR studies revealed the ultra violet cut-off wavelength of MFCTC in ethanol as 338 nm. The dielectric constant and dielectric loss of the sample were studied as a function of frequency and temperature. The TGA-DTA and DSC thermal analysis show that the sample is thermally stable up to 234.31 °C, which is comparatively far better than the thermal stability of Hg3CdCl2(SCN)6; (171.3 °C) and other metal-organic coordination complex crystals such as CdHg(SCN)4 (198.5 °C), Hg(N2H4CS)4Mn(SCN)4 (199.06 °C) and Hg(N2H4CS)4Zn(SCN)4 (185 °C). The SHG conversion efficiency of MFCTC is found to be higher than KDP.
Fermi Large Area Telescope Observations of Misaligned Active Galactic Nuclei
NASA Astrophysics Data System (ADS)
Abdo, A. A.; Ackermann, M.; Ajello, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Brandt, T. J.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Buehler, R.; Burnett, T. H.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Cannon, A.; Caraveo, P. A.; Carrigan, S.; Casandjian, J. M.; Cavazzuti, E.; Cecchi, C.; Çelik, Ö.; Celotti, A.; Charles, E.; Chekhtman, A.; Chen, A. W.; Cheung, C. C.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Colafrancesco, S.; Conrad, J.; Davis, D. S.; Dermer, C. D.; de Angelis, A.; de Palma, F.; Silva, E. do Couto e.; Drell, P. S.; Dubois, R.; Favuzzi, C.; Fegan, S. J.; Ferrara, E. C.; Fortin, P.; Frailis, M.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giglietto, N.; Giommi, P.; Giordano, F.; Giroletti, M.; Glanzman, T.; Godfrey, G.; Grandi, P.; Grenier, I. A.; Grove, J. E.; Guillemot, L.; Guiriec, S.; Hadasch, D.; Hayashida, M.; Hays, E.; Horan, D.; Hughes, R. E.; Jackson, M. S.; Jóhannesson, G.; Johnson, A. S.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Knödlseder, J.; Kuss, M.; Lande, J.; Latronico, L.; Lee, S.-H.; Lemoine-Goumard, M.; Llena Garde, M.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Madejski, G. M.; Makeev, A.; Malaguti, G.; Mazziotta, M. N.; McConville, W.; McEnery, J. E.; Michelson, P. F.; Migliori, G.; Mitthumsiri, W.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Naumann-Godo, M.; Nestoras, I.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohsugi, T.; Okumura, A.; Omodei, N.; Orlando, E.; Ormes, J. F.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Persic, M.; Pesce-Rollins, M.; Piron, F.; Porter, T. A.; Rainò, S.; Rando, R.; Razzano, M.; Razzaque, S.; Reimer, A.; Reimer, O.; Reyes, L. C.; Roth, M.; Sadrozinski, H. F.-W.; Sanchez, D.; Sander, A.; Scargle, J. D.; Sgrò, C.; Siskind, E. J.; Smith, P. D.; Spandre, G.; Spinelli, P.; Stawarz, Ł.; Stecker, F. W.; Strickman, M. S.; Suson, D. J.; Takahashi, H.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Thompson, D. J.; Tibaldo, L.; Torres, D. F.; Torresi, E.; Tosti, G.; Tramacere, A.; Uchiyama, Y.; Usher, T. L.; Vandenbroucke, J.; Vasileiou, V.; Vilchez, N.; Villata, M.; Vitale, V.; Waite, A. P.; Wang, P.; Winer, B. L.; Wood, K. S.; Yang, Z.; Ylinen, T.; Ziegler, M.
2010-09-01
Analysis is presented for 15 months of data taken with the Large Area Telescope (LAT) on the Fermi Gamma-ray Space Telescope for 11 non-blazar active galactic nuclei (AGNs), including seven FRI radio galaxies and four FRII radio sources consisting of two FRII radio galaxies and two steep spectrum radio quasars. The broad line FRI radio galaxy 3C 120 is reported here as a γ-ray source for the first time. The analysis is based on directional associations of LAT sources with radio sources in the 3CR, 3CRR, and MS4 (collectively referred to as 3C-MS) catalogs. Seven of the eleven LAT sources associated with 3C-MS radio sources have spectral indices larger than 2.3 and, except for the FRI radio galaxy NGC 1275 that shows possible spectral curvature, are well described by a power law. No evidence for time variability is found for any sources other than NGC 1275. The γ-ray luminosities of FRI radio galaxies are significantly smaller than those of the BL Lac objects detected by the LAT, whereas the γ-ray luminosities of the FRII sources are quite similar to those of FSRQs, which could reflect different beaming factors for the γ-ray emission. A core dominance (CD) study of the 3CRR sample indicates that sources closer to the jet axis are preferentially detected with the Fermi LAT, insofar as the γ-ray-detected misaligned AGNs have larger CD at a given average radio flux. The results are discussed in view of the AGN unification scenario.
Three dimensional chiral plasmon rulers based on silver nanorod trimers.
Han, Chunrui; Yang, Lechen; Ye, Piao; Parrott, Edward P J; Pickwell-Macpherson, Emma; Tam, Wing Yim
2018-04-16
The symmetry dependences of plasmon excitation modes are studied in 3D silver nanorod trimers. The degenerate plasmon modes split into chiral modes by breaking the inversion and mirror symmetry of the nanorod trimer through translation and/or rotation of the middle rod. With a translation operation, successive evolution of the circular dichroism (CD) spectrum can be achieved through gradual breaking of the inversion symmetry. An additional rotation operation produces even dramatic spectral changes due to breaking a quasi-mirror symmetry resulted from the same angular distance of the middle rod to the top and bottom rods. Especially, pairs of new chiral modes can be excited due to the contact of the middle rod with the top-bottom rod pair. The spectral changes in the simulations, which are also demonstrated experimentally, envision the 3D chiral nanorod trimer system as plasmon ruler for spatial configuration retrieval and dynamic bio-process analysis at the single molecule level.
Intramolecular charge transfer effects on 4-hydroxy-3-methoxybenzaldehyde
NASA Astrophysics Data System (ADS)
Rajendiran, N.; Balasubramanian, T.
2008-03-01
The absorption and fluorescence spectral characteristics of 4-hydroxy-3-methoxybenzaldehyde (HMB) have been studied in different solvents, pH and β-cyclodextrin (β-CD) and compared with 4-hydroxy-3,5-dimethoxybenzaldehyde (HDMB). The inclusion complex of HMB with β-CD is analysed by UV-vis, fluorimetry, FT-IR, 1H NMR, SEM and AM1 methods. In HMB, the normal emission (B band) is originates from a locally excited state and the longer emission (A band) is due to intramolecular charge transfer state (ICT). The OH group of HMB is present in the interior part of the β-CD cavity and aldehyde group present in the upper part of the β-CD cavity.
A facile and green preparation of high-quality CdTe semiconductor nanocrystals at room temperature
NASA Astrophysics Data System (ADS)
Liu, Yan; Shen, Qihui; Yu, Dongdong; Shi, Weiguang; Li, Jixue; Zhou, Jianguang; Liu, Xiaoyang
2008-06-01
One chemical reagent, hydrazine hydrate, was discovered to accelerate the growth of semiconductor nanocrystals (cadmium telluride) instead of additional energy, which was applied to the synthesis of high-quality CdTe nanocrystals at room temperature and ambient conditions within several hours. Under this mild condition the mercapto stabilizers were not destroyed, and they guaranteed CdTe nanocrystal particle sizes with narrow and uniform distribution over the largest possible range. The CdTe nanocrystals (photoluminescence emission range of 530-660 nm) synthesized in this way had very good spectral properties; for instance, they showed high photoluminescence quantum yield of up to 60%. Furthermore, we have succeeded in detecting the living Borrelia burgdorferi of Lyme disease by its photoluminescence image using CdTe nanocrystals.
Novel benzil and isoflavone derivatives from Millettia dielsiana.
Gong, Ting; Wang, Dong-Xiao; Chen, Ruo-Yun; Liu, Ping; Yu, De-Quan
2009-02-01
The analysis of vine stem extract from MILLETTIA DIELSIANA Harms yielded a novel benzil ( 1) and five new prenylated isoflavones ( 2 - 6) together with three known isoflavones ( 7 - 10) and one known flavone ( 11), and their structures were elucidated on the basis of chemical and spectral analysis. The absolute configuration of the 3'',4''-diols in 6 was determined by observing the CD induced after addition of dimolybdenum tetraacetate in DMSO solution (Snatzke's method). Some isolates were tested for their anti-inflammatory and antithrombase activities and cytotoxicities. Compound 2, barbigerone, and genistein showed significant anti-inflammatory activity, with inhibitory ratios 59.1 %, 59.5 %, and 58.5 %, respectively, at 10 muM, while compound 4 exhibited moderate cytotoxicity.
Detector response function of an energy-resolved CdTe single photon counting detector.
Liu, Xin; Lee, Hyoung Koo
2014-01-01
While spectral CT using single photon counting detector has shown a number of advantages in diagnostic imaging, knowledge of the detector response function of an energy-resolved detector is needed to correct the signal bias and reconstruct the image more accurately. The objective of this paper is to study the photo counting detector response function using laboratory sources, and investigate the signal bias correction method. Our approach is to model the detector response function over the entire diagnostic energy range (20 keV
LWIR hyperspectral imager based on a diffractive optics lens
NASA Astrophysics Data System (ADS)
Gupta, Neelam
2009-05-01
A diffractive optics lens based longwave infrared hyperspectral imager has been used to collect laboratory and outdoor field test data. The imager uses a specially designed diffractive optics Ge lens with a 320×256 HgCdTe focal plane array (FPA) cooled with a Sterling-cooler. The imager operates in 8-10.5 μm (long wave IR, LWIR) spectral region and an image cube with 50 to 200 bands can be acquired rapidly. Spectral images at different wavelengths are obtained by moving the lens along its optical axis. An f/2.38 diffractive lens is used with a focal length of 70 mm at 8 μm. The IFOV is 0.57 mrad which corresponds to an FOV of 10.48°. The spectral resolution of the imager is 0.034 μm at 9 μm. The pixel size is 40×40 μm2 in the FPA. In post processing of image cube data contributions due to wavelengths other than the focused one are removed and a correction to account for the change in magnification due to the motion of the lens is applied to each spectral image. A brief description of the imager, data collection and analysis to characterize the performance of the imager will be presented in this paper.
NASA Astrophysics Data System (ADS)
Konstantinova, E.; Zyubin, A.; Moiseeva, E.; Matveeva, K.; Slezhkin, V.; Samusev, I.; Bryukhanov, V.
2017-12-01
The study of the luminescence of CdZnSeS / ZnS quantum dots (QDs) absorbed on the rough surface of a silver film, including the energy transfer between human serum albumin molecules, isolated from the blood plasma of healthy and infected with sepsis patients, was performed by spectral-kinetic methods.
LWIR HgCdTe Detectors Grown on Ge Substrates
NASA Astrophysics Data System (ADS)
Vilela, M. F.; Lofgreen, D. D.; Smith, E. P. G.; Newton, M. D.; Venzor, G. M.; Peterson, J. M.; Franklin, J. J.; Reddy, M.; Thai, Y.; Patten, E. A.; Johnson, S. M.; Tidrow, M. Z.
2008-09-01
Long-wavelength infrared (LWIR) HgCdTe p-on- n double-layer heterojunctions (DLHJs) for infrared detector applications have been grown on 100 mm Ge (112) substrates by molecular beam epitaxy (MBE). The objective of this current work was to grow our baseline p-on- n DLHJ detector structure (used earlier on Si substrates) on 100 mm Ge substrates in the 10 μm to 11 μm LWIR spectral region, evaluate the material properties, and obtain some preliminary detector performance data. Material characterization techniques included are X-ray rocking curves, etch pit density (EPD) measurements, compositional uniformity determined from Fourier-transform infrared (FTIR) transmission, and doping concentrations determined from secondary-ion mass spectroscopy (SIMS). Detector properties include resistance-area product (RoA), spectral response, and quantum efficiency. Results of LWIR HgCdTe detectors and test structure arrays (TSA) fabricated on both Ge and silicon (Si) substrates are presented and compared. Material properties demonstrated include X-ray full-width of half-maximum (FWHM) as low as 77 arcsec, typical etch pit densities in mid 106 cm-2 and wavelength cutoff maximum/minimum variation <2% across the full wafer. Detector characteristics were found to be nearly identical for HgCdTe grown on either Ge or Si substrates.
NASA Astrophysics Data System (ADS)
Ibnaouf, K. H.
2015-04-01
The spectral properties of a conjugated polymer poly [2-methoxy-5-(2-ethylhexyloxy)-1, 4-phenylenevinylene] (MEH-PPV) in benzene have been studied intensively. The fluorescence spectra for MEH-PPV, under low concentrations, have shown two peaks around 560 nm and 600 nm, which could be attributed to the monomer and excimer states respectively. In our earlier communication, we had shown that MEH-PPV alone could produce amplified spontaneous emission (ASE) only in its excimeric state (600 nm). The spectral properties of 5 nm size of CdSe (core) quantum dots have been investigated. The fluorescence spectra of CdSe core in benzene showed only one band at 590 nm. Mixtures made of MEH-PPV and CdSe (core) quantum dots have been utilized for studying the amplified spontaneous emission characteristics (ASE) in an organic solution under laser excitation. When the mixture was pumped by the third harmonic of Nd:YAG (355 nm), we observed two ASE peaks; one at 575 nm and another at 595 nm. These ASE peaks could arise from the monomer and excimer states of MEH-PPV. This is perhaps the first report on the influence of quantum dots on the laser from the conjugated polymer MEH-PPV, in liquid solution.
NASA Astrophysics Data System (ADS)
Kaiser, Uwe; Sabir, Nadeem; Carrillo-Carrion, Carolina; del Pino, Pablo; Bossi, Mariano; Heimbrodt, Wolfram; Parak, Wolfgang J.
2016-02-01
Manganese-doped CdS/ZnS quantum dots have been used as energy donors in a Förster-like resonance energy transfer (FRET) process to enhance the effective lifetime of organic fluorophores. It was possible to tune the effective lifetime of the fluorophores by about six orders of magnitude from the nanosecond (ns) up to the millisecond (ms) region. Undoped and Mn-doped CdS/ZnS quantum dots functionalized with different dye molecules were selected as a model system for investigating the multiple energy transfer process and the specific interaction between Mn ions and the attached dye molecules. While the lifetime of the free dye molecules was about 5 ns, their linking to undoped CdS/ZnS quantum dots led to a long effective lifetime of about 150 ns, following a non-exponential transient. Manganese-doped core-shell quantum dots further enhanced the long-lasting decay time of the dye to several ms. This opens up a pathway to analyse different fluorophores in the time domain with equal spectral emissions. Such lifetime multiplexing would be an interesting alternative to the commonly used spectral multiplexing in fluorescence detection schemes.
Punniyakotti, J; Ponnusamy, V
2018-02-01
Natural radioactivity content and heavy metal concentration in the intertidal zone sand samples from the southern region of Tamil Nadu coast, India, have been analyzed using gamma ray spectrometer and ICP-OES, respectively. From gamma spectral analysis, the average radioactivity contents of 238 U, 232 Th, and 40 K in the intertidal zone sand samples are 12.13±4.21, 59.03±4.26, and 197.03±26.24Bq/kg, respectively. The average radioactivity content of 232 Th alone is higher than the world average value. From the heavy metal analysis, the average Cd, Cr, Cu, Ni, Pb, and Zn concentrations are 3.1, 80.24, 82.84, 23.66, 91.67, and 137.07ppm, respectively. The average Cr and Ni concentrations are lower, whereas other four metal (Cd, Cu, Pb, and Zn) concentrations are higher than world surface rock average values. From pollution assessment parameter values, the pollution level is "uncontaminated to moderately contaminated" in the study area. Copyright © 2017 Elsevier Ltd. All rights reserved.
Enhanced numerical analysis of three-color HgCdTe detectors
NASA Astrophysics Data System (ADS)
Jóźwikowski, K.; Rogalski, A.
2007-04-01
The performance of three-color HgCdTe photovoltaic heterostructure detector is examined theoretically. In comparison with two-color detectors with two back-to-back junctions, three-color structure contain an absorber of intermediate wavelength placed between two junctions, and electronic barriers are used to isolate this intermediate region. This structure was first proposed by British workers. Enhanced original computer programs are applied to solve the system of non-linear continuity equations for carriers and Poisson equations. In addition, the numerical analysis includes the dependence of absorption coefficient on Burstein effect as well as interference effects in heterostructure with metallic electrical contacts. Three detector structures with different localizations of separating barriers are analyzed. The calculations results are presented in the form of spatial distributions of bandgap energy and quantum efficiency. It is shown that the performance of the detector is critically dependent on the barrier's doping level and position in relation to the junction. This behavior is serious disadvantage of the considered three color detector. A small shift of the barrier location and doping level causes serious changes in spectral responsivity.
Numerical analysis of three-colour HgCdTe detectors
NASA Astrophysics Data System (ADS)
Jóźwikowski, K.; Rogalski, A.
2007-12-01
The performance of three-colour HgCdTe photovoltaic heterostructure detector is examined theoretically. In comparison with two-colour detectors with two back-to-back junctions, three-colour structure contains an absorber of intermediate wavelength placed between two junctions and electronic barriers are used to isolate this intermediate region. This structure was first proposed by British workers. Three-detector structures with different localizations of separating barriers are analyzed. The calculation results are presented in the form of spatial distributions of bandgap energy and quantum efficiency. Enhanced original computer programs are applied to solve the system of non-linear continuity equations for carriers and Poisson equations. In addition, the numerical analysis includes the dependence of absorption coefficient on Burstein effect as well as interference effects in heterostructure with metallic electrical contacts. It is shown that the performance of the detector is critically dependent on the barrier’s doping level and position in relation to the junction. This behaviour is serious disadvantage of the considered three-colour detector. A small shift of the barrier location and doping level causes serious changes in spectral responsivity.
Gaponik, Nikolai; Gerlach, Matthias; Donegan, John F; Savateeva, Diana; Rogach, Andrey L
2006-01-01
We have studied the photoluminescence and Raman spectra of a system consisting of a polystyrene latex microsphere coated by CdTe colloidal quantum dots. The cavity-induced enhancement of the Raman scattering allows the observation of Raman spectra from only a monolayer of CdTe quantum dots. Periodic structure with very narrow peaks in the photoluminescence spectra of a single microsphere was detected both in the Stokes and anti-Stokes spectral regions, arising from the coupling between the emission of quantum dots and spherical cavity modes.
High color rendering index WLED based on YAG:Ce phosphor and CdS/ZnS core/shell quantum dots
NASA Astrophysics Data System (ADS)
Shen, Changyu; Li, Ke
2009-08-01
White LED combining of blue chip and YAG:Ce phosphor suffers from a red spectral deficiency, resulting in a relatively low value of color rendering index (CRI). In our study, for an effort to improve color rendering properties of YAG:Ce phosphor-based white LEDs, highly luminescent red-orange emitting CdS/ZnS QDs were blended with YAG:Ce phosphors. Core/shell CdS/ZnS quantum dots with the emission wavelength of 618nm, was synthesized by thermal deposition using cadmium oxide and selenium as precursors in a hot lauric acid and hexadecylamine trioctylphosphine oxide hybrid. YAG:Ce phosphor was synthesized by high-temperature solid state reaction at 900-1200°C in a slightly reducing atmosphere for 4 hours. Blends of phosphors and QDs exhibited the prominent spectral evolution with an increasing content of QDs. A hybrid white LED, which combines a blue LED with the blend of YAG phosphor and QDs with a weight ratio of 1.5:1,was demonstrated with an improved CRI value of 86.
Growth and characterization of metal doped and quasi mixed crystals based on ZnCd(SCN)4
NASA Astrophysics Data System (ADS)
Latha, C.; Mahadevan, C. K.; Guo, Li; Liu, Jinghe
2018-03-01
In order to understand the effect of forming hybrid crystals by doping with metallic impurities or by quasi mixing on the physicochemical properties of the basic material crystal, we have grown by the free evaporation method at room temperature and characterized (chemically, structurally, optically and electrically) un-doped and K+/Ca2+/Mn2+/Mg2+/Cu2+ doped (with 1 mol% concentration) ZnCd(SCN)4 and ZnxCd(2-x)(SCN)4 (with x = 0.0, 0.4, 0.8, 1.2, 1.6 and 2.0) single crystals. Single crystals could be grown with x = 0.0 (leading to Cd(SCN)2) but not when x = 2.0 (leading to Zn(SCN)2). Results obtained in the present study through X-ray diffraction and EDAX spectral measurements indicate the formation of the above hybrid crystals. The optical (UV-Vis-NIR spectral and SHG efficiency) measurements indicate significant changes in optical transmittance and SHG efficiency due to doping as well as quasi mixing. Dielectric measurements made in the temperature range 40-150 °C with a fixed frequency of 1 kHz indicate a normal dielectric behavior for all the eleven crystals grown. Moreover, the present study indicates an increase of dielectric constant and SHG efficiency when ZnCd(SCN)4 crystal is doped with a metallic impurity whereas a decrease of dielectric constant and SHG efficiency when quasi mixing is done.
Scott, Riccardo; Achtstein, Alexander W; Prudnikau, Anatol V; Antanovich, Artsiom; Siebbeles, Laurens D A; Artemyev, Mikhail; Woggon, Ulrike
2016-10-12
We present a study of the application potential of CdSe nanoplatelets (NPLs), a model system for colloidal 2D materials, as field-controlled emitters. We demonstrate that their emission can be changed by 28% upon application of electrical fields up to 175 kV/cm, a very high modulation depth for field-controlled nanoemitters. From our experimental results we estimate the exciton binding energy in 5.5 monolayer CdSe nanoplatelets to be E B = 170 meV; hence CdSe NPLs exhibit highly robust excitons which are stable even at room temperature. This opens up the possibility to tune the emission and recombination dynamics efficiently by external fields. Our analysis further allows a quantitative discrimination of spectral changes of the emission energy and changes in PL intensity related to broadening of the emission line width as well as changes in the intrinsic radiative rates which are directly connected to the measured changes in the PL decay dynamics. With the developed field-dependent population model treating all occurring field-dependent effects in a global analysis, we are able to quantify, e.g., the ground state exciton transition dipole moment (3.0 × 10 -29 Cm) and its polarizability, which determine the radiative rate, as well as the (static) exciton polarizability (8.6 × 10 -8 eV cm 2 /kV 2 ), all in good agreement with theory. Our results show that an efficient field control over the exciton recombination dynamics, emission line width, and emission energy in these nanoparticles is feasible and opens up application potential as field-controlled emitters.
NASA Astrophysics Data System (ADS)
Karaağaç, Dursun; Kürkçüoğlu, Güneş Süheyla
2016-02-01
Polymeric tetracyanonickelate(II) complexes of the type [M(L)2Ni(CN)4]n (Ldbnd N-methylethylenediamine (men) or N-ethylethylenediamine (neen); Mdbnd Ni(II), Cu(II), Zn(II) or Cd(II)) have been prepared and characterized by FT-IR, Raman spectroscopy, thermal and elemental analysis techniques. Additionally, FT-IR and Raman spectral analyses of men and neen have experimentally and theoretically investigated in the range of 4000-250 cm-1. The corresponding vibration assignments of men and neen are performed by using B3LYP density functional theory (DFT) method together with 6-31 G(d) basis set. The spectral features of the complexes suggest that the coordination environment of the M(II) ions are surrounded by the two symmetry related men and neen ligands and the two symmetry related N atom of cyanide groups, whereas the Ni(II) atoms are coordinated with a square-planar to four C atoms of the cyanide groups. Polymeric structures of the complexes consist of one dimensional alternative chains of [M(L)2]2+ and [Ni(CN)4]2- moieties. The thermal decompositions in the temperature range 30-700 °C of the complexes were investigated in the static air atmosphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Rekha, E-mail: rekha.mittal07@gmail.com; Kumar, Dinesh; Chaudhary, Sujeet
2016-05-06
Cadmium sulfide (CdS) thin films have been deposited on conducting glass substrates by chemical bath deposition (CBD) technique. The effect of precursor concentration on the structural, morphological, compositional, and optical properties of the CdS films has been studied. Crystal structure of these CdS films is characterized by X-ray diffraction (XRD) and it reveals polycrystalline structure with mixture of cubic and wurtzite phases with grain size decreasing as precursor concentration is increased. Optical studies reveal that the CdS thin films have high transmittance in visible spectral region reaching 90% and the films possess direct optical band gap that decreases from 2.46more » to 2.39 eV with decreasing bath concentration. Our study suggests that growth is nucleation controlled.« less
Synthesis and Study of Optical Characteristics of Ti0.91O2/CdS Hybrid Sphere Structures
NASA Astrophysics Data System (ADS)
Kong, Lingbin; Xu, Qinfeng; Zhang, Meng; Wang, Dehua; Liu, Mingliang; Zhang, Lei; Jiao, Mengmeng; Wang, Honggang; Yang, Chuanlu
2018-03-01
The optical properties of alternating ultrathin Ti0.91O2 nanosheets and CdS nanoparticle hybrid spherical structures designed by the layer-by-layer (LBL) assembly technique are investigated. From the photoluminescence (PL) spectral measurements on the hybrid spherical structures, a spectrum-shifted fluorescence emission occurs in this novel hybrid material. The time-resolved PL measurements exhibit a remarkably increased PL lifetime of 3.75 ns compared with only Ti0.91O2 spheres or CdS nanoparticles. The novel results were attributed to the enhanced electron-hole separation due to the new type II indirect optical transition mechanism between Ti0.91O2 and CdS in a charge-separated configuration.
NASA Astrophysics Data System (ADS)
DeWames, Roger E.
2016-05-01
In this paper we review the intrinsic and extrinsic technological properties of the incumbent technology, InP/In0.53Ga0.47As/InP, for imaging in the visible- short wavelength spectral band, InSb and HgCdTe for imaging in the mid-wavelength spectral band and HgCdTe for imaging in the long wavelength spectral band. These material systems are in use for a wide range of applications addressing compelling needs in night vision imaging, low light level astronomical applications and defense strategic satellite sensing. These materials systems are direct band gap energy semiconductors hence the internal quantum efficiency η, is near unity over a wide spectral band pass. A key system figure of merit of a shot noise limited detector technology is given by the equation (1+Jdark. /Jphoton), where Jdark is the dark current density and Jphoton ~qηΦ is the photocurrent density; Φ is the photon flux incident on the detector and q is the electronic charge. The capability to maintain this factor for a specific spectral band close to unity for low illumination conditions and low temperature onset of non-ideal dark current components, basically intrinsic diffusion limited performance all the way, is a marker of quality and versatility of a semiconductor detector technology. It also enables the highest temperature of operation for tactical illumination conditions. A purpose of the work reported in this paper is to explore the focal plane array data sets of photodiode detector technologies widely used to bench mark their fundamental and technology properties and identify paths for improvements.
Stanish, Paul C.; Radovanovic, Pavle V.
2016-01-01
Developing solid state materials capable of generating homogeneous white light in an energy efficient and resource-sustainable way is central to the design of new and improved devices for various lighting applications. Most currently-used phosphors depend on strategically important rare earth elements, and rely on a multicomponent approach, which produces sub-optimal quality white light. Here, we report the design and preparation of a colloidal white-light emitting nanocrystal conjugate. This conjugate is obtained by linking colloidal Ga2O3 and II–VI nanocrystals in the solution phase with a short bifunctional organic molecule (thioglycolic acid). The two types of nanocrystals are electronically coupled by Förster resonance energy transfer owing to the short separation between Ga2O3 (energy donor) and core/shell CdSe/CdS (energy acceptor) nanocrystals, and the spectral overlap between the photoluminescence of the donor and the absorption of the acceptor. Using steady state and time-resolved photoluminescence spectroscopies, we quantified the contribution of the energy transfer to the photoluminescence spectral power distribution and the corresponding chromaticity of this nanocrystal conjugate. Quantitative understanding of this new system allows for tuning of the emission color and the design of quasi-single white light emitting inorganic phosphors without the use of rare-earth elements. PMID:28344289
Evaluation of a HgCdTe e-APD based detector for 2 μm CO2 DIAL application.
Dumas, Arnaud; Rothman, Johan; Gibert, Fabien; Édouart, Dimitri; Lasfargues, Gilles; Cénac, Claire; Mounier, Florian Le; Pellegrino, Jessica; Zanatta, Jean-Paul; Bardoux, Alain; Tinto, Francesc; Flamant, Pierre
2017-09-20
Benefiting from close to ideal amplification properties (high gain, low dark current, and low excess noise factor), HgCdTe electron initiated avalanche photodiode (e-APD) technology exhibits state of the art sensitivity, thus being especially relevant for applications relying on low light level detection, such as LIDAR (Light Detection And Ranging). In addition, the tunable gap of the Hg 1-x Cd x Te alloy enables coverage of the short wavelength infrared (SWIR) and especially the 2 μm spectral range. For these two reasons, a HgCdTe e-APD based detector is a promising candidate for future differential absorption LIDAR missions targeting greenhouse gas absorption bands in SWIR. In this study, we report on the design and evaluation of such a HgCdTe e-APD based detector. The first part focuses on detector architecture and performance. Key figures of merit are: 2.8 μm cutoff wavelength, 200 μm diameter almost circular sensitive area, 185 K operating temperature (thermo-electric cooling), 22 APD gain (at 12 V reverse bias), 360 kΩ transimpedance gain, and 60 fWHz -0.5 noise equivalent power (at 12 V reverse bias). The second part presents an analysis of atmospheric LIDAR signals obtained by mounting the HgCdTe e-APD based detector on the 2 μm differential absorption LIDAR developed at the Laboratoire de Météorologie Dynamique and dedicated to CO 2 monitoring. Discussion emphasizes random and systematic errors in LIDAR measurements regarding breadboard detector characterization. In particular, we investigate the influence of parasitic tails in detector impulse response on short range DIAL measurements.
Calibration of the hard x-ray detectors for the FOXSI solar sounding rocket
NASA Astrophysics Data System (ADS)
Athiray, P. S.; Buitrago-Casas, Juan Camilo; Bergstedt, Kendra; Vievering, Juliana; Musset, Sophie; Ishikawa, Shin-nosuke; Glesener, Lindsay; Takahashi, Tadayuki; Watanabe, Shin; Courtade, Sasha; Christe, Steven; Krucker, Säm.; Goetz, Keith; Monson, Steven
2017-08-01
The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment conducts direct imaging and spectral observation of the Sun in hard X-rays, in the energy range 4 to 20 keV. These high-sensitivity observations are used to study particle acceleration and coronal heating. FOXSI is designed with seven grazing incidence optics modules that focus X-rays onto seven focal plane detectors kept at a 2m distance. FOXSI-1 was flown with seven Double-sided Si Strip Detectors (DSSD), and two of them were replaced with CdTe detectors for FOXSI-2. The upcoming FOXSI-3 flight will carry DSSD and CdTe detectors with upgraded optics for enhanced sensitivity. The detectors are calibrated using various radioactive sources. The detector's spectral response matrix was constructed with diagonal elements using a Gaussian approximation with a spread (sigma) that accounts for the energy resolution of the detector. Spectroscopic studies of past FOXSI flight data suggest that the inclusion of lower energy X-rays could better constrain the spectral modeling to yield a more precise temperature estimation of the hot plasma. This motivates us to carry out an improved calibration to better understand the finer-order effects on the spectral response, especially at lower energies. Here we report our improved calibration of FOXSI detectors using experiments and Monte-Carlo simulations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marshall, Ashley R.; Young, Matthew R.; Nozik, Arthur J.
2015-08-06
We explored the uptake of metal chloride salts with +1 to +3 metals of Na+, K+, Zn2+, Cd2+, Sn2+, Cu2+, and In3+ by PbSe QD solar cells. We also compared CdCl2 to Cd acetate and Cd nitrate treatments. PbSe QD solar cells fabricated with a CdCl2 treatment are stable for more than 270 days stored in air. We studied how temperature and immersion times affect optoelectronic properties and photovoltaic cell performance. Uptake of Cd2+ and Zn2+ increase open circuit voltage, whereas In3+ and K+ increase the photocurrent without influencing the spectral response or first exciton peak position. Using the mostmore » beneficial treatments we varied the bandgap of PbSe QD solar cells from 0.78 to 1.3 eV and find the improved VOC is more prevalent for lower bandgap QD solar cells.« less
Fluorescence spectral shift of QD films with electron injection: Dependence on counterion proximity
NASA Astrophysics Data System (ADS)
Lu, Meilin; Li, Bo; Zhang, Yaxin; Liu, Weilong; Yang, Yanqiang; Wang, Yuxiao; Yang, Qingxin
2017-05-01
Due to the promising application of quantum dot (QD) films in solar cells, LEDs and environmental detectors, the fluorescence of charged QD films has achieved much attention during recent years. In this work, we observe the spectral shift of photoluminescence (PL) in charged CdSe/ZnS QD films controlled by electrochemical potential. The spectral center under negative bias changes from red-shift to blue-shift while introducing smaller inorganic counterions (potassium ions) into the electrolyte. This repeatable effect is attributed to the enhanced electron injection with smaller cations and the electronic perturbations of QD luminescence by these excess charges.
A path to practical Solar Pumped Lasers via Radiative Energy Transfer
Reusswig, Philip D.; Nechayev, Sergey; Scherer, Jennifer M.; ...
2015-10-05
The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd 3+ -doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CWmore » solar lasing threshold of 23 W-cm -2, or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns.« less
A path to practical Solar Pumped Lasers via Radiative Energy Transfer
Reusswig, Philip D.; Nechayev, Sergey; Scherer, Jennifer M.; Hwang, Gyu Weon; Bawendi, Moungi G.; Baldo, Marc. A.; Rotschild, Carmel
2015-01-01
The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd3+-doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CW solar lasing threshold of 23 W-cm−2, or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns. PMID:26434400
Understanding the features in the ultrafast transient absorption spectra of CdSe quantum dots
NASA Astrophysics Data System (ADS)
Zhang, Cheng; Do, Thanh Nhut; Ong, Xuanwei; Chan, Yinthai; Tan, Howe-Siang
2016-12-01
We describe a model to explain the features of the ultrafast transient absorption (TA) spectra of CdSe core type quantum dots (QDs). The measured TA spectrum consists of contributions by the ground state bleach (GSB), stimulated emission (SE) and excited state absorption (ESA) processes associated with the three lowest energy transition of the QDs. We model the shapes of the GSB, SE and ESA spectral components after fits to the linear absorption. The spectral positions of the ESA components take into account the biexcitonic binding energy. In order to obtain the correct weightage of the GSB, SE and ESA components to the TA spectrum, we enumerate the set of coherence transfer pathways associated with these processes. From our fits of the experimental TA spectra of 65 Å diameter QDs, biexcitonic binding energies for the three lowest energy transitions are obtained.
A path to practical Solar Pumped Lasers via Radiative Energy Transfer.
Reusswig, Philip D; Nechayev, Sergey; Scherer, Jennifer M; Hwang, Gyu Weon; Bawendi, Moungi G; Baldo, Marc A; Rotschild, Carmel
2015-10-05
The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd(3+)-doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CW solar lasing threshold of 23 W-cm(-2), or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns.
Spectral Estimation Model Construction of Heavy Metals in Mining Reclamation Areas
Dong, Jihong; Dai, Wenting; Xu, Jiren; Li, Songnian
2016-01-01
The study reported here examined, as the research subject, surface soils in the Liuxin mining area of Xuzhou, and explored the heavy metal content and spectral data by establishing quantitative models with Multivariable Linear Regression (MLR), Generalized Regression Neural Network (GRNN) and Sequential Minimal Optimization for Support Vector Machine (SMO-SVM) methods. The study results are as follows: (1) the estimations of the spectral inversion models established based on MLR, GRNN and SMO-SVM are satisfactory, and the MLR model provides the worst estimation, with R2 of more than 0.46. This result suggests that the stress sensitive bands of heavy metal pollution contain enough effective spectral information; (2) the GRNN model can simulate the data from small samples more effectively than the MLR model, and the R2 between the contents of the five heavy metals estimated by the GRNN model and the measured values are approximately 0.7; (3) the stability and accuracy of the spectral estimation using the SMO-SVM model are obviously better than that of the GRNN and MLR models. Among all five types of heavy metals, the estimation for cadmium (Cd) is the best when using the SMO-SVM model, and its R2 value reaches 0.8628; (4) using the optimal model to invert the Cd content in wheat that are planted on mine reclamation soil, the R2 and RMSE between the measured and the estimated values are 0.6683 and 0.0489, respectively. This result suggests that the method using the SMO-SVM model to estimate the contents of heavy metals in wheat samples is feasible. PMID:27367708
Spectral Estimation Model Construction of Heavy Metals in Mining Reclamation Areas.
Dong, Jihong; Dai, Wenting; Xu, Jiren; Li, Songnian
2016-06-28
The study reported here examined, as the research subject, surface soils in the Liuxin mining area of Xuzhou, and explored the heavy metal content and spectral data by establishing quantitative models with Multivariable Linear Regression (MLR), Generalized Regression Neural Network (GRNN) and Sequential Minimal Optimization for Support Vector Machine (SMO-SVM) methods. The study results are as follows: (1) the estimations of the spectral inversion models established based on MLR, GRNN and SMO-SVM are satisfactory, and the MLR model provides the worst estimation, with R² of more than 0.46. This result suggests that the stress sensitive bands of heavy metal pollution contain enough effective spectral information; (2) the GRNN model can simulate the data from small samples more effectively than the MLR model, and the R² between the contents of the five heavy metals estimated by the GRNN model and the measured values are approximately 0.7; (3) the stability and accuracy of the spectral estimation using the SMO-SVM model are obviously better than that of the GRNN and MLR models. Among all five types of heavy metals, the estimation for cadmium (Cd) is the best when using the SMO-SVM model, and its R² value reaches 0.8628; (4) using the optimal model to invert the Cd content in wheat that are planted on mine reclamation soil, the R² and RMSE between the measured and the estimated values are 0.6683 and 0.0489, respectively. This result suggests that the method using the SMO-SVM model to estimate the contents of heavy metals in wheat samples is feasible.
Assigning the low lying vibronic states of CH3O and CD3O
NASA Astrophysics Data System (ADS)
Johnson, Britta A.; Sibert, Edwin L.
2017-05-01
The assignment of lines in vibrational spectra in strongly mixing systems is considered. Several low lying vibrational states of the ground electronic X˜ 2E state of the CH3O and CD3O radicals are assigned. Jahn-Teller, spin-orbit, and Fermi couplings mix the normal mode states. The mixing complicates the assignment of the infrared spectra using a zero-order normal mode representation. Alternative zero-order representations, which include specific Jahn-Teller couplings, are explored. These representations allow for definitive assignments. In many instances it is possible to plot the wavefunctions on which the assignments are based. The plots, which are shown in the adiabatic representation, allow one to visualize the effects of various higher order couplings. The plots also enable one to visualize the conical seam and its effect on the wavefunctions. The first and the second order Jahn-Teller couplings in the rocking motion dominate the spectral features in CH3O, while first order and modulated first order couplings dominate the spectral features in CD3O. The methods described here are general and can be applied to other Jahn-Teller systems.
Modeling and Measuring Charge-Sharing in Hard X-ray Imagers Using HEXITEC CdTe Detectors
NASA Technical Reports Server (NTRS)
Ryan, Daniel F.; Christe, Steven D.; Shih, Albert Y.; Baumgartner, Wayne H.; Wilson, Matthew D.; Seller, Paul; Gaskin, Jessica A.; Inglis, Andrew
2017-01-01
The Rutherford Appleton Laboratory's HEXITEC ASIC has been designed to provide fine pixelated X-ray spectroscopic imaging in combination with a CdTe or CZT detector layer. Although HEXITEC's small pixels enable higher spatial resolution as well as higher spectral resolution via the small-pixel effect, they also increase the probability of charge sharing, a process which degrades spectral performance by dividing the charge induced by a single photon among multiple pixels. In this paper, we investigate the effect of this process on a continuum X-ray spectrum below the Cd and Te fluorescence energies (23 keV). This is done by comparing laboratory measurements with simulations performed with a custom designed model of the HEXITEC ASIC. We find that the simulations closely match the observations implying that we have an adequate understanding of both charge sharing and the HEXITEC ASIC itself. These results can be used to predict the distortion of a spectrum measured with HEXITEC and will help determine to what extent it can be corrected. They also show that models like this one are important tools in developing and interpreting observations from ASICs like HEXITEC.
BOREAS RSS-14 Level-1 GOES-8 Visible, IR and Water Vapor Images
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Faysash, David; Cooper, Harry J.; Smith, Eric A.; Newcomer, Jeffrey A.
2000-01-01
The BOREAS RSS-14 team collected and processed several GOES-7 and GOES-8 image data sets that covered the BOREAS study region. The level-1 BOREAS GOES-8 images are raw data values collected by RSS-14 personnel at FSU and delivered to BORIS. The data cover 14-Jul-1995 to 21-Sep-1995 and 01-Jan-1996 to 03-Oct-1996. The data start out containing three 8-bit spectral bands and end up containing five 10-bit spectral bands. No major problems with the data have been identified. The data are contained in binary image format files. Due to the large size of the images, the level-1 GOES-8 data are not contained on the BOREAS CD-ROM set. An inventory listing file is supplied on the CD-ROM to inform users of what data were collected. The level-1 GOES-8 image data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). See sections 15 and 16 for more information. The data files are available on a CD-ROM (see document number 20010000884).
Ultra-Low Dark Current HgCdTe Detector in SWIR for Space Applications
NASA Astrophysics Data System (ADS)
Cervera, C.; Boulade, O.; Gravrand, O.; Lobre, C.; Guellec, F.; Sanson, E.; Ballet, P.; Santailler, J. L.; Moreau, V.; Zanatta, J. P.; Fieque, B.; Castelein, P.
2017-10-01
This paper presents recent developments at Commissariat à l'Energie atomique, Laboratoire d'Electronique et de Technologie de l'Information infrared laboratory on processing and characterization of p-on- n HgCdTe (MCT) planar infrared focal plane arrays (FPAs) in short-wave infrared (SWIR) spectral band for the astrophysics applications. These FPAs have been grown using both liquid phase epitaxy and molecular beam epitaxy on a lattice-matched CdZnTe substrate. This technology exhibits lower dark current and lower series resistance in comparison with n-on- p vacancy-doped architecture and is well adapted for low flux detection or high operating temperature. This architecture has been evaluated for space applications in long-wave infrared and very-long-wave infrared spectral bands with cut-off wavelengths from 10 μm up to 17 μm at 78 K and is now evaluated for the SWIR range. The metallurgical nature of the absorbing layer is also examined and both molecular beam epitaxy and liquid phase epitaxy have been investigated. Electro-optical characterizations have been performed on individual photodiodes from test arrays, whereas dark current investigation has been performed with a fully functional readout integrated circuit dedicated to low flux operations.
Zhang, Guowen; Ma, Yadi
2013-11-01
The interaction between sodium benzoate (SB) and calf thymus DNA in simulated physiological buffer (pH 7.4) using acridine orange (AO) dye as a fluorescence probe, was investigated by UV-Vis absorption, fluorescence and circular dichroism (CD) spectroscopy along with DNA melting studies and viscosity measurements. An expanded UV-Vis spectral data matrix was resolved by multivariate curve resolution-alternating least squares (MCR-ALS) approach. The equilibrium concentration profiles and the pure spectra for SB, DNA and DNA-SB complex from the high overlapping composite response were simultaneously obtained. The results indicated that SB could bind to DNA, and hydrophobic interactions and hydrogen bonds played a vital role in the binding process. Moreover, SB was able to quench the fluorescence of DNA-AO complex through a static procedure. The quenching observed was indicative of an intercalative mode of interaction between SB and DNA, which was supported by melting studies, viscosity measurements and CD analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Syncarpamide, a new antiplasmodial (+)-norepinephrine derivative from Zanthoxylum syncarpum.
Ross, Samir A; Sultana, Gazi N N; Burandt, Charles L; ElSohly, Mahmoud A; Marais, Jannie P J; Ferreira, Daneel
2004-01-01
A new (+)-norepinephrine derivative, syncarpamide (1), along with a known coumarin, (+)-S-marmesin (2), and one known alkaloid, decarine (3), have been isolated from the stem of Zanthoxylum syncarpum. The structure of compound 1 was elucidated on the basis of 1D and 2D NMR, MS, IR, optical rotation, and CD analyses. Its absolute stereochemistry was elucidated by synthesis of its enantiomer and subsequent comparison of CD data. Characterizations of compounds 2 and 3 were based on spectral analysis and comparison with reported data. Compounds 1 and 3 showed antiplasmodial activity, with IC(50) values of 2.04 and 1.44 microM against Plasmodium falciparum D(6) clone and 3.06 and 0.88 microM against P. falciparum W(2) clone, respectively. Compound 3 showed cytotoxicity at 56.42 microM, whereas compound 1 was not cytotoxic at 10.42 microM. Compound 1 was tested for hypotensive activity, but no activity was observed. Compound 2 showed no antiplasmodial or antimicrobial activities.
ASTRO-H CdTe detectors proton irradiation at PIF
NASA Astrophysics Data System (ADS)
Limousin, O.; Renaud, D.; Horeau, B.; Dubos, S.; Laurent, P.; Lebrun, F.; Chipaux, R.; Boatella Polo, C.; Marcinkowski, R.; Kawaharada, M.; Watanabe, S.; Ohta, M.; Sato, G.; Takahashi, T.
2015-07-01
ASTRO-H will be operated in a Low Earth Orbit with a 31° inclination at 550 km altitude, thus passing daily through the South Atlantic Anomaly radiation belt, a specially harsh environment where the detectors are suffering the effect of the interaction with trapped high energy protons. As CdTe detector performance might be affected by the irradiation, we investigate the effect of the accumulated proton fluence on their spectral response. To do so, we have characterized and irradiated representative samples of SGD and HXI detector under different conditions. The detectors in question, from ACRORAD, are single-pixels having a size of 2 mm by 2 mm and 750 μm thick. The Schottky contact is either made of an Indium or Aluminum for SGD and HXI respectively. We ran the irradiation test campaign at the Proton Irradiation Facility (PIF) at PSI, and ESA approved equipment to evaluate the radiation hardness of flight hardware. We simulated the proton flux expected on the sensors over the entire mission, and secondary neutrons flux due to primary proton interactions into the surrounding BGO active shielding. We eventually characterized the detector response evolution, emphasizing each detector spectral response as well as its stability by studying the so-called Polarization effect. The latter is provoking a spectral response degradation against time as a charge accumulation process occurs in Schottky type CdTe sensors. In this paper, we report on the test campaigns at PIF and will show up our experimental setup. We will pursue describing the irradiation conditions associated with our GEANT 4 predictions and finally, we report the main results of our campaigns concluding that the proton effect does not severely affect the CdTe response neither the detector stability while the secondary neutrons might be more active to reduce the performance on the long run.
Cassini infrared Fourier spectroscopic investigation
NASA Astrophysics Data System (ADS)
Kunde, Virgil G.; Ade, Peter A.; Barney, Richard D.; Bergman, D.; Bonnal, Jean-Francois; Borelli, R.; Boyd, D.; Brasunas, John C.; Brown, G.; Calcutt, S. B.; Carroll, F.; Courtin, R.; Cretolle, Jacky; Crooke, Julie A.; Davis, Martin A.; Edberg, S.; Fettig, R.; Flasar, M.; Glenar, David A.; Graham, S.; Hagopian, John G.; Hakun, C. F.; Hayes, Patricia A.; Herath, L.; Horn, Linda; Jennings, Donald E.; Karpati, G.; Kellebenz, C.; Lakew, Brook; Lindsay, J.; Lohr, J.; Lyons, James J.; Martineau, Robert J.; Martino, Anthony J.; Matsumura, M.; McCloskey, J.; Melak, T.; Michel, G.; Morell, Armando; Mosier, C.; Pack, L.; Plants, M.; Robinson, D.; Rodriguez, Louis; Romani, Paul; Schaefer, W. J.; Schmidt, Steve; Trujillo, C.; Vellacott, Tim; Wagner, K.; Yun, D.
1996-10-01
The composite infrared spectrometer (CIRS) is a remote sensing instrument to be flown on the Cassini orbiter. CIRS will retrieve vertical profiles of temperature and gas composition for the atmospheres of Titan and Saturn, from deep in their tropospheres to high in their stratospheres. CIRS will also retrieve information on the thermal properties and composition of Saturn's rings and Saturnian satellites. CIRS consists of a pair of Fourier Transform Spectrometers (FTSs) which together cover the spectral range from 10-1400 cm-1 with a spectral resolution up to 0.5 cm-1. The two interferometers share a 50 cm beryllium Cassegrain telescope. The far-infrared FTS is a polarizing interferometer covering the 10-600 cm-1 range with a pair of thermopile detectors, and a 3.9 mrad field of view. The mid-infrared FTS is a conventional Michelson interferometer covering 200-1400 cm-1 in two spectral bandpasses: 600-1100 cm- 1100-1400 cm(superscript -1 with a 1 by 10 photovoltaic HgCdTe array. Each pixel of the arrays has an approximate 0.3 mrad field of view. The HgCdTe arrays are cooled to approximately 80K with a passive radiative cooler.
2012-05-01
instrument was equipped with deuterated triglycine sulfide and mercury-cadmium-telluride ( HgCdTe ) detectors and was capable of obtaining spectra with...helium-neon [HeNe] laser zero-crossing frequency) using the HgCdTe detector . Absorbance spectra of the vapor effluent were computed using background...weak [a = 0.00021 (umol/mol) ’m ’, which gave a prediction of A ~ 0.001] and close to the detector cutoff (root mean square [RMS] noise = 0.0002 A
Passive Ranging Using Infra-Red Atmospheric Attenuation
2010-03-01
was the Bomem MR-154 Fourier Transform Spectrometer (FTS). The FTS used both an HgCdTe and InSb detector . For this study, the primary source of data...also outfitted with an HgCdTe and InSb detector . Again, only data from the InSb detector was used. The spectral range of data collected was from...an uncertainty in transmittance of 0.01 (figure 20). This would yield an error in range of 6%. Other sources of error include detector noise or
Siddappa, Kuruba; Mane, Sunilkumar B.
2014-01-01
A simple condensation of 3-amino-2-methylquinazoline-4-one with 2-hydroxy-1-naphthaldehyde produced new tridentate ONO donor Schiff base ligand with efficient yield. The structural characterization of ligand and its Cu(II), Ni(II), Co(II), Mn(II), Zn(II), and Cd(II) complexes were achieved by the aid of elemental analysis, spectral characterization such as (UV-visible, IR, NMR, mass, and ESR), and magnetic data. The analytical and spectroscopic studies suggest the octahedral geometries of Cu(II), Co(II), Ni(II) and Mn(II) complexes and tetrahedral geometry of Zn(II) and Cd(II) complexes with the tridentate ONO Schiff base ligand. Furthermore, the conclusions drawn from these studies afford further support to the mode of bonding discussed on the basis of their 3D molecular modeling studies by considering different bond lengths, bond angles, and bond distance. The ligand and its metal complexes evaluated for their antimicrobial activity against Staphylococcus aureus (MTCC number 7443), Bacillus subtilis (MTCC number 9878), Escherichia coli (MTCC number 1698), Aspergillus niger (MTCC number 281), and Aspergillus flavus (MTCC number 277). The MIC of these compounds was found to be most active at 10 μg/mL concentration in inhibiting the growth of the tested organisms. The DNA cleavage activity of all the complexes was studied by gel electrophoresis method. PMID:24678278
The band structure of birefractive CdGa2S4 crystals
NASA Astrophysics Data System (ADS)
Stamov, I. G.; Syrbu, N. N.; Parvan, V. I.; Zalamai, V. V.; Tiginyanu, I. M.
2013-11-01
In this paper, we report on the spectral dependence of Δn=no-ne for CdGa2S4 single crystals for shorter and longer wavelengths than the isotropic wavelength λ0=485.7 nm (300 K). It was established that Δn is positive at λ>λ0 and it is negative in the spectral range λ<λ0. The isotropic wavelength λ0 exhibits blue spectral shift with temperature decreasing. The ground and excited states of three excitonic series A, B and C with binding energies of 53 meV, 52 meV and 46 meV, respectively, were found out at 10 K. The effective masses of electrons for k=0 were derived from the calculation of excitonic spectra: mc∥(Е∥с)=0.21m0 and mc⊥(Е⊥с)=0.19m0. The holes masses are equal to 0.59m0 and 0.71m0 for Е∥с and Е⊥с, respectively. The value of valence bands splitting, V1-V2, by crystalline field equals 24 meV, and V2-V3 splitting due to the spin-orbital interaction equals to 130 meV. The optical functions n, k, ε1 and ε2 for Е⊥с and Е∥с polarizations were calculated by means of Kramers-Kronig analyses in the energy interval 3-6 eV. The evidenced features are discussed taking into account the results of new theoretical calculations of CdGa2S4 band structure.
Removal of uranium from soil samples for ICP-OES analysis of RCRA metals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wero, M.; Lederer-Cano, A.; Billy, C.
1995-12-01
Soil samples containing high levels of uranium present unique analytical problems when analyzed for toxic metals (Ag, As, Ba, Cd, Cr, Cu, Ni, Pb, Se and Tl) because of the spectral interference of uranium in the ICP-OES emission spectrometer. Methods to remove uranium from the digestates of soil samples, known to be high in uranium, have been developed that reduce the initial uranium concentration (1-3%) to less than 500 ppm. UTEVA ion exchange columns, used as an ICP-OES analytical pre-treatment, reduces uranium to acceptable levels, permitting good analytical results of the RCRA metals by ICP-OES.
2009-06-01
additionally be utilized to cover a wider spectral range. In recent years, the long-wave IR ( LWIR : 8–12 m) region of the electromagnetic spectrum has been... LWIR region, and they can be sensed by their apparent temper- atures and spectral signatures in the LWIR . Currently, there are three main material...technologies for photonic IR photodetectors in the LWIR region. The HgCdTe (MCT) detector is the current state of the art due to its high responsivity
Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications
NASA Astrophysics Data System (ADS)
Barber, W. C.; Wessel, J. C.; Nygard, E.; Iwanczyk, J. S.
2015-06-01
We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non-destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including: the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half-maximum (FWHM) across the entire dynamic range, and a noise floor about 20 keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications.
Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications
Barber, W. C.; Wessel, J. C.; Nygard, E.; Iwanczyk, J. S.
2014-01-01
We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including; the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half maximum (FWHM) across the entire dynamic range, and a noise floor about 20keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications. PMID:25937684
Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.
Barber, W C; Wessel, J C; Nygard, E; Iwanczyk, J S
2015-06-01
We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including; the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half maximum (FWHM) across the entire dynamic range, and a noise floor about 20keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications.
Swain, Ratnakar; Sahoo, Bhabagrahi
2017-05-01
For river water quality monitoring at 30m × 1-day spatio-temporal scales, a spatial and temporal adaptive reflectance fusion model (STARFM) is developed for estimating turbidity (T u ), total suspended solid (TSS), and six heavy metals (HV) of iron, zinc, copper, chromium, lead and cadmium, by blending the Moderate-Resolution Imaging Spectroradiometer (MODIS) and Landsat (L s ) spectral bands. A combination of regression analysis and genetic algorithm (GA) techniques are applied to develop spectral relationships between T u -L s , TSS-T u , and each HV-TSS. The STARFM algorithm and all the developed relationship models are evaluated satisfactorily by various performance evaluation measures to develop heavy metal pollution index-based vulnerability maps at 1-km resolution in the Brahmani River in eastern India. The Monte-Carlo simulation based analysis of the developed formulations reveals that the uncertainty in estimating Zn and Cd is the minimum (1.04%) and the maximum (5.05%), respectively. Hence, the remote sensing based approach developed herein can effectively be used in many world rivers for real-time monitoring of heavy metal pollution. Copyright © 2017 Elsevier Ltd. All rights reserved.
Interaction of Water-Soluble CdTe Quantum Dots with Bovine Serum Albumin
2011-01-01
Semiconductor nanoparticles (quantum dots) are promising fluorescent markers, but it is very little known about interaction of quantum dots with biological molecules. In this study, interaction of CdTe quantum dots coated with thioglycolic acid (TGA) with bovine serum albumin was investigated. Steady state spectroscopy, atomic force microscopy, electron microscopy and dynamic light scattering methods were used. It was explored how bovine serum albumin affects stability and spectral properties of quantum dots in aqueous media. CdTe–TGA quantum dots in aqueous solution appeared to be not stable and precipitated. Interaction with bovine serum albumin significantly enhanced stability and photoluminescence quantum yield of quantum dots and prevented quantum dots from aggregating. PMID:27502633
Ultraspectral imaging for propulsion test monitoring
NASA Astrophysics Data System (ADS)
Otten, Leonard John, III; Jones, Bernard A.; Prinzing, Philip; Swantner, William H.; Rafert, Bruce
2002-02-01
Under a NASA Stennis Space Center (SSC) SBIR, technologies required for an imaging spectral radiometer with wavenumber spectral resolution and milliradian spatial resolution that operates over the 8 micrometers to 12 micrometers (LWIR), and 3 micrometers to 5 micrometers (MWIR) bands, for use in a non-intrusive monitoring static rocket firing application are being investigated. The research is based on a spatially modulated Fourier transform spectral imager to take advantage of the inherent benefits in these devices in the MWIR and LWIR. The research verified optical techniques that could be merged with a Sagnac interferometer to create conceptual designs for an LWIR imaging spectrometer that has a 0.4 cm-1 spectral resolution using an available HgCdTe detector. These same techniques produce an MWIR imaging spectrometer with 1.5 cm-1 spectral resolution based on a commercial InSb array. Initial laboratory measurements indicate that the modeled spectral resolution is being met. Applications to environmental measurement applications under standard temperatures can be undertaken by taking advantage of several unique features of the Sagnac interferometer in being able to decouple the limiting aperature from the spectral resolution.
Dunphy, C H; Polski, J M; Evans, H L; Gardner, L J
2001-08-01
Immunophenotyping of bone marrow (BM) specimens with acute myelogenous leukemia (AML) may be performed by flow cytometric (FC) or immunohistochemical (IH) techniques. Some markers (CD34, CD15, and CD117) are available for both techniques. Myeloperoxidase (MPO) analysis may be performed by enzyme cytochemical (EC) or IH techniques. To determine the reliability of these markers and MPO by these techniques, we designed a study to compare the results of analyses of these markers and MPO by FC (CD34, CD15, and CD117), EC (MPO), and IH (CD34, CD15, CD117, and MPO) techniques. Twenty-nine AMLs formed the basis of the study. These AMLs all had been immunophenotyped previously by FC analysis; 27 also had had EC analysis performed. Of the AMLs, 29 had BM core biopsies and 26 had BM clots that could be evaluated. The paraffin blocks of the 29 BM core biopsies and 26 BM clots were stained for CD34, CD117, MPO, and CD15. These results were compared with results by FC analysis (CD34, CD15, and CD117) and EC analysis (MPO). Immunodetection of CD34 expression in AML had a similar sensitivity by FC and IH techniques. Immunodetection of CD15 and CD117 had a higher sensitivity by FC analysis than by IH analysis. Detection of MPO by IH analysis was more sensitive than by EC analysis. There was no correlation of French-American-British (FAB) subtype of AML with CD34 or CD117 expression. Expression of CD15 was associated with AMLs with a monocytic component. Myeloperoxidase reactivity by IH analysis was observed in AMLs originally FAB subtyped as M0. CD34 can be equally detected by FC and IH techniques. CD15 and CD117 are better detected by FC analysis and MPO is better detected by IH analysis.
Sumathi, R. B.; Halli, M. B.
2014-01-01
A new Schiff base and a new series of Co(II), Ni(II), Cu(II), Cd(II), and Hg(II) complexes were synthesized by the condensation of naphthofuran-2-carbohydrazide and diacetylmonoxime. Metal complexes of the Schiff base were prepared from their chloride salts of Co(II), Ni(II), Cu(II), Cd(II), and Hg(II) in ethanol. The ligand along with its metal complexes have been characterized on the basis of analytical data, IR, electronic, mass, 1HNMR, ESR spectral data, thermal studies, magnetic susceptibility, and molar conductance measurements. The nonelectrolytic behaviour of the complexes was assessed from the measured low conductance data. The elemental analysis of the complexes confirm the stoichiometry of the type CuL2Cl2 and MLCl2 where M = Ni(II), Co(II), Cd(II), and Hg(II) and L = Schiff base. The redox property of the Cu(II) complex was investigated by electrochemical method using cyclic voltammetry. In the light of these results, Co(II), Ni(II), and Cu(II) complexes are assigned octahedral geometry, Cd(II), and Hg(II) complexes tetrahedral geometry. In order to evaluate the effect of metal ions upon chelation, both the ligand and its metal complexes were screened for their antibacterial and antifungal activities by minimum inhibitory concentration (MIC) method. The DNA cleaving capacity of all the complexes was analysed by agarose gel electrophoresis method. PMID:24592203
Correlations of charge neutrality level with electronic structure and p-d hybridization
Das, Arkaprava; Gautam, Subodh K.; Shukla, D. K.; Singh, Fouran
2017-01-01
The formation of charge neutrality level (CNL) in highly conducting Cadmium oxide (CdO) thin films is demonstarted by the observed variation in the band gap upon annealing and doping. It may be explained by the observation that Tin (Sn) doping breaks the perfect periodicity of CdO cubic crystal structure and creates virtual gap states (ViGS). The level of local CNL resides at the branch point of ViGS, making the energy at which native defect’s character changes from predominantly donor-like below CNL to predominantly acceptor-like above the CNL and a schematic band diagram is developed to substantiate the same. Further investigations using soft x-ray absorption spectroscopy (SXAS) at Oxygen and Cadmium edges show the reduction of Sn4+ to Sn2+. The analysis of the spectral features has revealed an evidence of p-d interaction between O 2p and Cd 4d orbitals that pushes the valence band minima at higher energies which is symmetry forbidden at г point and causing a positive valance band dispersion away from the zone centre in the г ~ L, K direction. Thus, origin of the CNL is attributed to the high density of the Oxygen vacancies as confirmed by the change in the local electronic structure and p-d hybridization of orbitals. PMID:28102312
White LED based on CaAl2Si2O8:Eu2+ Mn2+ phosphor and CdS/ZnS quantum dots
NASA Astrophysics Data System (ADS)
Shen, Changyu; Zhong, Chuan; Hou, Qianglong; Li, Ke
2011-02-01
Core/shell CdS/ZnS quantum dots (QDs) with the emission wavelength of 610nm, was synthesized by thermal deposition using cadmium oxide and selenium as precursors in a hot lauric acid and hexadecylamine trioctylphosphine oxide hybrid. CaAl2Si2O8:Eu2+ Mn2+ phosphor was synthesized by high-temperature solid state reaction at 1290 °C for 2 hours under the H2 reducing atmosphere, and X-ray powder diffraction analysis confirmed the formation of it. It has two emission bands peaking at 420 nm and 580nm originated from the transition 5d to 4f of Eu2+ and 4T1-6A1 of Mn2+, respectively. Blends of CaAl2Si2O8:Eu2+,Mn2+ phosphor and CdS/ZnS QDs exhibited the prominent spectral evolution with an increasing content of QDs. A hybrid white LED, which combines a blue LED with the blend of CaAl2Si2O8:Eu2+ Mn2+ phosphor and QDs with a weight ratio of 2:1, with the CIE coordinate of (0.3183, 0.3036) and CRI of 85 was obtained.
Correlations of charge neutrality level with electronic structure and p-d hybridization
NASA Astrophysics Data System (ADS)
Das, Arkaprava; Gautam, Subodh K.; Shukla, D. K.; Singh, Fouran
2017-01-01
The formation of charge neutrality level (CNL) in highly conducting Cadmium oxide (CdO) thin films is demonstarted by the observed variation in the band gap upon annealing and doping. It may be explained by the observation that Tin (Sn) doping breaks the perfect periodicity of CdO cubic crystal structure and creates virtual gap states (ViGS). The level of local CNL resides at the branch point of ViGS, making the energy at which native defect’s character changes from predominantly donor-like below CNL to predominantly acceptor-like above the CNL and a schematic band diagram is developed to substantiate the same. Further investigations using soft x-ray absorption spectroscopy (SXAS) at Oxygen and Cadmium edges show the reduction of Sn4+ to Sn2+. The analysis of the spectral features has revealed an evidence of p-d interaction between O 2p and Cd 4d orbitals that pushes the valence band minima at higher energies which is symmetry forbidden at г point and causing a positive valance band dispersion away from the zone centre in the г ~ L, K direction. Thus, origin of the CNL is attributed to the high density of the Oxygen vacancies as confirmed by the change in the local electronic structure and p-d hybridization of orbitals.
Molina, Iñigo; Martinez, Estibaliz; Arquero, Agueda; Pajares, Gonzalo; Sanchez, Javier
2012-01-01
Landcover is subject to continuous changes on a wide variety of temporal and spatial scales. Those changes produce significant effects in human and natural activities. Maintaining an updated spatial database with the occurred changes allows a better monitoring of the Earth’s resources and management of the environment. Change detection (CD) techniques using images from different sensors, such as satellite imagery, aerial photographs, etc., have proven to be suitable and secure data sources from which updated information can be extracted efficiently, so that changes can also be inventoried and monitored. In this paper, a multisource CD methodology for multiresolution datasets is applied. First, different change indices are processed, then different thresholding algorithms for change/no_change are applied to these indices in order to better estimate the statistical parameters of these categories, finally the indices are integrated into a change detection multisource fusion process, which allows generating a single CD result from several combination of indices. This methodology has been applied to datasets with different spectral and spatial resolution properties. Then, the obtained results are evaluated by means of a quality control analysis, as well as with complementary graphical representations. The suggested methodology has also been proved efficiently for identifying the change detection index with the higher contribution. PMID:22737023
Molina, Iñigo; Martinez, Estibaliz; Arquero, Agueda; Pajares, Gonzalo; Sanchez, Javier
2012-01-01
Landcover is subject to continuous changes on a wide variety of temporal and spatial scales. Those changes produce significant effects in human and natural activities. Maintaining an updated spatial database with the occurred changes allows a better monitoring of the Earth's resources and management of the environment. Change detection (CD) techniques using images from different sensors, such as satellite imagery, aerial photographs, etc., have proven to be suitable and secure data sources from which updated information can be extracted efficiently, so that changes can also be inventoried and monitored. In this paper, a multisource CD methodology for multiresolution datasets is applied. First, different change indices are processed, then different thresholding algorithms for change/no_change are applied to these indices in order to better estimate the statistical parameters of these categories, finally the indices are integrated into a change detection multisource fusion process, which allows generating a single CD result from several combination of indices. This methodology has been applied to datasets with different spectral and spatial resolution properties. Then, the obtained results are evaluated by means of a quality control analysis, as well as with complementary graphical representations. The suggested methodology has also been proved efficiently for identifying the change detection index with the higher contribution.
Study of polarized IR spectra of the hydrogen bond system in crystals of styrylacetic acid
NASA Astrophysics Data System (ADS)
Flakus, Henryk T.; Jabłońska, Magdalena; Jones, Peter G.
2006-10-01
We have investigated the polarized IR spectra of the hydrogen bond system in crystals of trans-styrylacetic acid C 6H 5sbnd CH dbnd CH sbnd CH 2sbnd COOH, and also in crystals of the following three deuterium isotopomers of the compound: C 6H 5sbnd CH dbnd CH sbnd CH 2sbnd COOD, C 6H 5sbnd CH dbnd CH sbnd CD 2sbnd COOH and C 6H 5sbnd CH dbnd CH sbnd CD 2sbnd COOD. The spectra were measured at room temperature and at 77 K by a transmission method. The spectral studies were preceded by determination of the X-ray crystal structure. Theoretical analysis of the results concerned linear dichroic effects, the H/D isotopic and temperature effects, observed in the solid-state IR spectra of the hydrogen and of the deuterium bond, at the frequency ranges of the νO sbnd H and the νO sbnd D bands, respectively. Basic spectral properties of the crystals can be interpreted satisfactorily in terms of the " strong-coupling" theory, when based on a hydrogen bond dimer model. This model sufficiently explained not only a two-branch structure of the νO sbnd H and the νO sbnd D bands, and temperature-induced evolution of the crystalline spectra, but also the linear dichroic effects observed in the band frequency ranges. A vibronic mechanism was analyzed, responsible for promotion of the symmetry-forbidden transition in the IR for the totally symmetric proton stretching vibrations in centrosymmetric hydrogen bond dimers. It was found to be of minor importance, when compared with analogous spectral properties of arylcarboxylic acid, or of cinnamic acid crystals. These effects were ascribed to a substantial weakening of electronic couplings between the hydrogen bonds of the associated carboxyl groups and the styryl radicals, associated with the separation of these groups in styrylacetic acid molecules by methylene groups in the molecules.
Seismic design parameters - A user guide
Leyendecker, E.V.; Frankel, A.D.; Rukstales, K.S.
2001-01-01
The 1997 NEHRP Recommended Provisions for Seismic Regulations for New Buildings (1997 NEHRP Provisions) introduced seismic design procedure that is based on the explicit use of spectral response acceleration rather than the traditional peak ground acceleration and/or peak ground velocity or zone factors. The spectral response accelerations are obtained from spectral response acceleration maps accompanying the report. Maps are available for the United States and a number of U.S. territories. Since 1997 additional codes and standards have also adopted seismic design approaches based on the same procedure used in the NEHRP Provisions and the accompanying maps. The design documents using the 1997 NEHRP Provisions procedure may be divided into three categories -(1) Design of New Construction, (2) Design and Evaluation of Existing Construction, and (3) Design of Residential Construction. A CD-ROM has been prepared for use in conjunction with the design documents in each of these three categories. The spectral accelerations obtained using the software on the CD are the same as those that would be obtained by using the maps accompanying the design documents. The software has been prepared to operate on a personal computer using a Windows (Microsoft Corporation) operating environment and a point and click type of interface. The user can obtain the spectral acceleration values that would be obtained by use of the maps accompanying the design documents, include site factors appropriate for the Site Class provided by the user, calculate a response spectrum that includes the site factor, and plot a response spectrum. Sites may be located by providing the latitude-longitude or zip code for all areas covered by the maps. All of the maps used in the various documents are also included on the CDROM
Arbitrary Multicolor Photodetection by Hetero-integrated Semiconductor Nanostructures
Sang, Liwen; Hu, Junqing; Zou, Rujia; Koide, Yasuo; Liao, Meiyong
2013-01-01
The typical photodetectors can only detect one specific optical spectral band, such as InGaAs and graphene-PbS quantum dots for near-infrared (NIR) light detection, CdS and Si for visible light detection, and ZnO and III-nitrides for UV light detection. So far, none of the developed photodetector can achieve the multicolor detection with arbitrary spectral selectivity, high sensitivity, high speed, high signal-to-noise ratio, high stability, and simplicity (called 6S requirements). Here, we propose a universal strategy to develop multicolor photodetectors with arbitrary spectral selectivity by integrating various semiconductor nanostructures on a wide-bandgap semiconductor or an insulator substrate. Because the photoresponse of each spectral band is determined by each semiconductor nanostructure or the semiconductor substrate, multicolor detection satisfying 6S requirements can be readily satisfied by selecting the right semiconductors. PMID:23917790
Blue and green electroluminescence from CdSe nanocrystal quantum-dot-quantum-wells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Y. F.; Cao, X. A., E-mail: xacao@mail.wvu.edu
2014-11-17
CdS/CdSe/ZnS quantum dot quantum well (QDQW) nanocrystals were synthesized using the successive ion layer adsorption and reaction technique, and their optical properties were tuned by bandgap and strain engineering. 3-monolayer (ML) CdSe QWs emitted blue photoluminescence at 467 nm with a spectral full-width-at-half-maximum of ∼30 nm. With a 3 ML ZnS cladding layer, which also acts as a passivating and strain-compensating layer, the QDQWs acquired a ∼35% quantum yield of the QW emission. Blue and green electroluminescence (EL) was obtained from QDQW light-emitting devices with 3–4.5 ML CdSe QWs. It was found that as the peak blueshifted, the overall EL was increasinglymore » dominated by defect state emission due to poor hole injection into the QDQWs. The weak EL was also attributed to strong field-induced charge separation resulting from the unique QDQW geometry, weakening the oscillator strength of optical transitions.« less
NASA Astrophysics Data System (ADS)
Abrar, M.; Iqbal, T.; Fahad, M.; Andleeb, M.; Farooq, Z.; Afsheen, S.
2018-05-01
In the present work, the laser-induced breakdown spectroscopy technique is applied to explore the concentration of toxic elements present in cosmetic materials. The elemental analysis of chromium (Cr), magnesium (Mg), cadmium (Cd) and lead (Pb) are selected as major elements and manganese (Mn), sodium (Na), potassium (P), sulfur (S), silicon (Si) and titanium (Ti) as minor elements in cosmetic products. In this technique, a plasma plume is generated by using an Nd:YAG Laser of 532 nm wavelength and spectral lines for the respective samples are observed. Four different samples of cosmetic products are selected, i.e. two samples for lipstick and two for eyeshadow. The observed spectral lines of all major and minor elements are used to calculate their concentration in all samples through the intensity ratio method. Among selected lipstick and eyeshadow samples, one sample is branded, and one is collected from the local market. It is observed that chromium, magnesium and lead have strong spectral lines and consequently show high concentration. The calculated concentrations are then compared to permissible limits set by the Food and Drug Administration with regard to the cosmetics industry. The concentration of these toxic elements in selected local cosmetic samples exceeds the safe permissible limit for human use and could lead to serious health problems.
Fluorescent CdSe QDs containing Bacillus licheniformis bioprobes for Copper (II) detection in water.
Yan, Zheng-Yu; Du, Qing-Qing; Wan, Dong-Yu; Lv, Hang; Cao, Zhi-Ran; Wu, Sheng-Mei
2017-12-01
Quantum dots (QDs) are semiconductor nanoparticles (NPs) that offer valuable functionality for cellular labeling, drug delivery, solar cells and quantum computation. In this study, we reported that CdSe QDs could be bio-synthesized in Bacillus licheniformis. After optimization, the obtained CdSe QDs exhibited a uniform particle size of 3.71±0.04nm with a maximum fluorescence emission wavelength at 550nm and the synthetical positive ratio can reach up to 87%. Spectral properties, constitution, particle sizes and crystalline phases of the CdSe QDs were systematically and integrally investigated. The CdSe QD-containing Bacillus licheniformis cells were further used as whole fluorescent bio-probes to detect copper (II) (Cu 2+ ) in water, which demonstrated a low limit of detection (0.91μM). The assay also showed a good selectivity for Cu 2+ over other ions including Al 3+ , Cd 2+ , Mg 2+ , K + , Na + , NH 4 + , Zn 2+ , CH 3 COO + , Pb 2+ and I - . Our study suggests the fluorescent CdSe QDs-containing Bacillus licheniformis bio-probes as a promising approach for detection of Cu 2+ in complex solution environment. Copyright © 2017. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simonds, Brian J.; Kheraj, Vipul; Department of Applied Physics, S. V. National Institute of Technology, Surat 395 007
2015-06-14
Laser processing of polycrystalline CdTe is a promising approach that could potentially increase module manufacturing throughput while reducing capital expenditure costs. For these benefits to be realized, the basic effects of laser irradiation on CdTe must be ascertained. In this study, we utilize surface photovoltage spectroscopy (SPS) to investigate the changes to the electronic properties of the surface of polycrystalline CdTe solar cell stacks induced by continuous-wave laser annealing. The experimental data explained within a model consisting of two space charge regions, one at the CdTe/air interface and one at the CdTe/CdS junction, are used to interpret our SPS results.more » The frequency dependence and phase spectra of the SPS signal are also discussed. To support the SPS findings, low-temperature spectrally-resolved photoluminescence and time-resolved photoluminescence were also measured. The data show that a modest laser treatment of 250 W/cm{sup 2} with a dwell time of 20 s is sufficient to reduce the effects of Fermi level pinning at the surface due to surface defects.« less
A Circular Dichroism Reference Database for Membrane Proteins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wallace,B.; Wien, F.; Stone, T.
2006-01-01
Membrane proteins are a major product of most genomes and the target of a large number of current pharmaceuticals, yet little information exists on their structures because of the difficulty of crystallising them; hence for the most part they have been excluded from structural genomics programme targets. Furthermore, even methods such as circular dichroism (CD) spectroscopy which seek to define secondary structure have not been fully exploited because of technical limitations to their interpretation for membrane embedded proteins. Empirical analyses of circular dichroism (CD) spectra are valuable for providing information on secondary structures of proteins. However, the accuracy of themore » results depends on the appropriateness of the reference databases used in the analyses. Membrane proteins have different spectral characteristics than do soluble proteins as a result of the low dielectric constants of membrane bilayers relative to those of aqueous solutions (Chen & Wallace (1997) Biophys. Chem. 65:65-74). To date, no CD reference database exists exclusively for the analysis of membrane proteins, and hence empirical analyses based on current reference databases derived from soluble proteins are not adequate for accurate analyses of membrane protein secondary structures (Wallace et al (2003) Prot. Sci. 12:875-884). We have therefore created a new reference database of CD spectra of integral membrane proteins whose crystal structures have been determined. To date it contains more than 20 proteins, and spans the range of secondary structures from mostly helical to mostly sheet proteins. This reference database should enable more accurate secondary structure determinations of membrane embedded proteins and will become one of the reference database options in the CD calculation server DICHROWEB (Whitmore & Wallace (2004) NAR 32:W668-673).« less
Single photon emission from charged excitons in CdTe/ZnTe quantum dots
NASA Astrophysics Data System (ADS)
Belyaev, K. G.; Rakhlin, M. V.; Sorokin, S. V.; Klimko, G. V.; Gronin, S. V.; Sedova, I. V.; Mukhin, I. S.; Ivanov, S. V.; Toropov, A. A.
2017-11-01
We report on micro-photoluminescence studies of individual self-organized CdTe/ZnTe quantum dots intended for single-photon-source applications in a visible spectral range. The quantum dots surface density below 1010 per cm2 was achieved by using a thermally activated regime of molecular beam epitaxy that allowed fabrication of etched mesa-structures containing only a few emitting quantum dots. The single photon emission with the autocorrelation function g(2)(0)<0.2 was detected and identified as recombination of charged excitons in the individual quantum dot.
Detection of Apoptosis and Necrosis in Normal Human Lung Cells Using 1H NMR Spectroscopy
NASA Astrophysics Data System (ADS)
Shih, Chwen-Ming; Ko, Wun-Chang; Yang, Liang-Yo; Lin, Chien-Ju; Wu, Jui-Sheng; Lo, Tsui-Yun; Wang, Shwu-Huey; Chen, Chien-Tsu
2005-05-01
This study aimed to detect apoptosis and necrosis in MRC-5, a normal human lung cell line, by using noninvasive proton nuclear magnetic resonance (1H NMR). Live MRC-5 cells were processed first for 1H NMR spectroscopy; subsequently their types and the percentage of cell death were assessed on a flow cytometer. Cadmium (Cd) and mercury (Hg) induced apoptosis and necrosis in MRC-5 cells, respectively, as revealed by phosphatidylserine externalization on a flow cytometer. The spectral intensity ratio of methylene (CH2) resonance (at 1.3 ppm) to methyl (CH3) resonance (at 0.9 ppm) was directly proportional to the percentage of apoptosis and strongly and positively correlated with PI staining after Cd treatment (r2 = 0.9868, P < 0.01). In contrast, this ratio only increased slightly within 2-h Hg treatment, and longer Hg exposure failed to produce further increase. Following 2-h Hg exposure, the spectral intensity of choline resonance (at 3.2 ppm) was abolished, but this phenomenon was absent in Cd-induced apoptosis. These findings together demonstrate that 1H NMR is a novel tool with a quantitative potential to distinguish apoptosis from necrosis as early as the onset of cell death in normal human lung cells.
Prediction of the association state of insulin using spectral parameters.
Uversky, Vladimir N; Garriques, Liza Nielsen; Millett, Ian S; Frokjaer, Sven; Brange, Jens; Doniach, Sebastian; Fink, Anthony L
2003-04-01
Human insulin exists in different association states, from monomer to hexamer, depending on the conditions. In the presence of zinc the "normal" state is a hexamer. The structural properties of 20 variants of human insulin were studied by near-UV circular dichroism, fluorescence spectroscopy, and small-angle X-ray scattering (SAXS). The mutants showed different degrees of association (monomer, dimers, tetramers, and hexamers) at neutral pH. A correlation was shown between the accessibility of tyrosines to acrylamide quenching and the degree of association of the insulin mutants. The near-UV CD spectra of the insulins were affected by protein association and by mutation-induced structural perturbations. However, the shape and intensity of difference CD spectra, obtained by subtraction of the spectra measured in 20% acetic acid (where all insulin species were monomeric) from the corresponding spectra measured at neutral pH, correlate well with the degree of insulin association. In fact, the near-UV CD difference spectra for monomeric, dimeric, tetrameric, and hexameric insulin are very distinctive, both in terms of intensity and shape. The results show that the spectral properties of the insulins reflect their state of association, and can be used to predict their oligomeric state. Copyright 2003 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 92:847-858, 2003
NASA Astrophysics Data System (ADS)
Kurková, Dana; Judas, Libor
2018-05-01
Gamma and X-ray energy spectra measured with semiconductor detectors suffer from various distortions, one of them being so-called "tailing" caused by an incomplete charge collection. Using the Hecht equation, a response matrix of size 321 × 321 was constructed which was used to correct the effect of incomplete charge collection. The correction matrix was constructed analytically for an arbitrary energy bin and the size of the energy bin thus defines the width of the spectral window. The correction matrix can be applied separately from other possible spectral corrections or it can be incorporated into an already existing response matrix of the detector. The correction was tested and its adjustable parameters were optimized on the line spectra of 57Co measured with a cadmium telluride (CdTe) detector in a spectral range from 0 up to 160 keV. The best results were obtained when the values of the free path of holes were spread over a range from 0.4 to 1.0 cm and weighted by a Gauss function. The model with the optimized parameter values was then used to correct the line spectra of 152Eu in a spectral range from 0 up to 530 keV. An improvement in the energy resolution at full width at half maximum from 2.40 % ± 0.28 % to 0.96 % ± 0.28 % was achieved at 344.27 keV. Spectra of "narrow spectrum series" beams, N120, N150, N200, N250 and N300, generated with tube voltages of 120 kV, 150 kV, 200 kV, 250 kV and 300 kV respectively, and measured with the CdTe detector, were corrected in the spectral range from 0 to 160 keV (N120 and N150) and from 0 to 530 keV (N200, N250, N300). All the measured spectra correspond both qualitatively and quantitatively to the available reference data after the correction. To obtain better correspondence between N150, N200, N250 and N300 spectra and the reference data, lower values of the free paths of holes (range from 0.16 to 0.65 cm) were used for X-ray spectra correction, which suggests energy dependence of the phenomenon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowland, Clare E.; Fedin, Igor; Diroll, Benjamin T.
Elevated temperature optoelectronic performance of semiconductor nanomaterials remains an important issue for applications. Here we examine two-dimensional CdSe nanoplatelets (NPs) and CdS/CdSe/CdS shell/core/shell sandwich NPs at temperatures ranging from 300-700 K using static and transient spectroscopies as well as in-situ transmission electron microscopy. NPs exhibit reversible changes in PL intensity, spectral position, and emission linewidth with temperature elevation up to ~500 K, losing a factor of ~8 to 10 in PL intensity at 400 K relative to ambient. Temperature elevation above ~500 K yields thickness dependent, irreversible degradation in optical properties. Electron microscopy relates stability of the NP morphology upmore » to near 600 K followed by sintering and evaporation at still higher temperatures. The mechanism of reversible PL loss, based on differences in decay dynamics between time-resolved photoluminescence and transient absorption, arise primarily from hole trapping in both NPs and sandwich NPs.« less
Pilla, Viviane; Alves, Leandro P; Iwazaki, Adalberto N; Andrade, Acácio A; Antunes, Andrea; Munin, Egberto
2013-09-01
Cadmium selenide/zinc sulfide (CdSe/ZnS) core-shell quantum dots (QDs) embedded in biocompatible materials were thermally and optically characterized with a thermal lens (TL) technique. Transient TL measurements were performed with a mode-mismatched, dual-beam (excitation and probe) configuration. A thermo-optical study of the CdSe/ZnS QDs was performed for different core diameters (3.5, 4.0, 5.2, and 6.6 nm) in aqueous solution and synthetic saliva, and three different core diameters (2.4, 2.9, and 4.1 nm) embedded in restorative dental resin (0.025% by mass). The thermal diffusivity results are characteristic of the biocompatible matrices. The radiative quantum efficiencies for aqueous solution and biofluid materials are dependent on the core size of the CdSe/ZnS core-shell QDs. The results obtained from the fluorescence spectral measurements for the biocompatible materials support the TL results.
Synthesis and spectral characterizations of trivalent ions (Cr3+, Fe3+) doped CdO nanopowders
NASA Astrophysics Data System (ADS)
Aswani, T.; Babu, B.; Pushpa Manjari, V.; Joyce Stella, R.; Thirumala Rao, G.; Rama Krishna, Ch.; Ravikumar, R. V. S. S. N.
2014-03-01
Trivalent transition metal ions (Cr3+, Fe3+) doped CdO nanopowders via sonication in the presence of Sodium lauryl sulfate as stabilizing agent were synthesized and characterized. Powder XRD studies indicate that the obtained CdO has a cubic phase and concluded that the trivalent ions doping induced the lattice constants to change some extent. Optical absorption spectra exhibited the characteristic bands of Cr3+ and Fe3+ ions in octahedral site symmetry. Crystal field (Dq) and inter-electronic repulsion (B and C) parameters are evaluated for Cr3+ doped CdO nanopowders as Dq = 1540, B = 619 and C = 3327 cm-1 and for Fe3+ doped CdO nanopowders Dq = 920, B = 690, C = 2750 cm-1. EPR spectra of the Cr3+ and Fe3+ doped CdO nanopowders exhibited resonances at g = 1.973 and g = 2 respectively which indicate distorted octahedral site for both ions with the host. Photoluminescence spectra shows the emission bands in violet and bluish green regions for Cr3+ doped CdO, ultraviolet and blue emissions for Fe3+ doped CdO nanopowders. The CIE chromaticity coordinates were also evaluated from the emission spectrum. FT-IR spectra indicate the presence of various functional groups of host lattice.
Wu, Wen-Ya; Li, Mingjie; Lian, Jie; Wu, Xiangyang; Yeow, Edwin K L; Jhon, Mark H; Chan, Yinthai
2014-09-23
We synthesized colloidal InP/ZnS seeded CdS tetrapods by harnessing the structural stability of the InP/ZnS seed nanocrystals at the high reaction temperatures needed to grow the CdS arms. Because of an unexpected Type II band alignment at the interface of the InP/ZnS core and CdS arms that enhanced the occurrence of radiative excitonic recombination in CdS, these tetrapods were found to be capable of exhibiting highly efficient multiexcitonic dual wavelength emission of equal intensity at spectrally distinct wavelengths of ∼485 and ∼675 nm. Additionally, the Type II InP/ZnS seeded CdS tetrapods displayed a wider range of pump-dependent emission color-tunability (from red to white to blue) within the context of a CIE 1931 chromaticity diagram and possessed higher photostability due to suppressed multiexcitonic Auger recombination when compared to conventional Type I CdSe seeded CdS tetrapods. By employing time-resolved spectroscopy measurements, we were able to attribute the wide emission color-tunability to the large valence band offset between InP and CdS. This work highlights the importance of band alignment in the synthetic design of semiconductor nanoheterostructures, which can exhibit color-tunable multiwavelength emission with high efficiency and photostability.
De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert
2004-07-01
Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.
Yamgar, B A; Sawant, V A; Bharate, B G; Chavan, S S
2011-01-01
A series of complexes of the type [M(L)(dppe)X2]; where M=Zn(II) or Cd(II); L=4-(2'-thiazolylazo)chlorobenzene (L1), 4-(2'-thiazolylazo)bromobenzene (L2) and 4-(2'-thiazolylazo) iodobenzene (L3); dppe=1,2-bis(diphenylphosphino)ethane; X=N3- or NCS- have been prepared and characterized on the basis of their microanalysis, molar conductance, thermal, IR, UV-vis and 1H NMR spectral studies. IR spectra show that the ligand L is coordinated to the metal atom in bidentate manner via azo nitrogen and thiazole nitrogen. An octahedral structure is proposed for all the complexes. The thermal behavior of the complexes revealed that the thiocyanato complexes are thermally more stable than the azido complexes. All the complexes exhibit blue-green emission with high quantum yield as the result of the fluorescence from the intraligand emission excited state. Copyright © 2010 Elsevier B.V. All rights reserved.
Targeting CD6 for the treatment of experimental autoimmune uveitis.
Zhang, Lingjun; Li, Yan; Qiu, Wen; Bell, Brent A; Dvorina, Nina; Baldwin, William M; Singer, Nora; Kern, Timothy; Caspi, Rachel R; Fox, David A; Lin, Feng
2018-06-01
CD6 is emerging as a new target for treating many pathological conditions in which T cells are integrally involved, but even the latest data from studies of CD6 gene engineered mice were still contradictory. To address this issue, we studied experimental autoimmune uveitis (EAU), a model of autoimmune uveitis, in wild-type (WT) and CD6 knockout (KO) mice. After EAU induction in WT and CD6 KO mice, we evaluated ocular inflammation and compared retinal antigen-specific T-cell responses using scanning laser ophthalmoscopy, spectral-domain optical coherence tomography, histopathology, and T cell recall assays. Uveitogenic T cells from WT and CD6 KO mice were adoptively transferred into WT naïve mice to confirm the impact of CD6 on T cells. In addition, we immunized CD6 KO mice with recombinant CD6 protein to develop mouse anti-mouse CD6 monoclonal antibodies (mAbs) in which functional antibodies exhibiting cross-reactivity with human CD6 were screened and identified for treatment studies. In CD6 KO mice with EAU, we found significantly decreased retinal inflammation and reduced autoreactive T-cell responses, and confirmed the impaired uveitogenic capacity of T cells from these mice in an adoptive transfer experiment. Notably, one of these cross-reactive mAbs significantly ameliorated retinal inflammation in EAU induced by the adoptive transfer of uveitogenic T cells. Together, these data strongly suggest that CD6 plays a previously unknown, but pivotal role in autoimmune uveitis, and may be a promising new treatment target for this blinding disease. In addition, the newly developed mouse anti-mouse/human CD6 mAbs could be valuable tools for testing CD6-targeted therapies in other mouse models of human diseases. Copyright © 2018 Elsevier Ltd. All rights reserved.
The effect of spectral filters on VEP and alpha-wave responses.
Willeford, Kevin T; Fimreite, Vanessa; Ciuffreda, Kenneth J
2016-01-01
Spectral filters are used to treat light sensitivity in individuals with traumatic brain injury (TBI); however, the effect of these filters on normal visual function has not been elucidated. Thus, the current study aimed to determine the effect of spectral filters on objectively-measured visual-evoked potential (VEP) and alpha-wave responses in the visually-normal population. The full-field (15°H×17°V), pattern-reversal VEP (20' check size, mean luminance 52cd/m(2)) was administered to 20 visually-normal individuals. They were tested with four Intuitive-Colorimeter-derived, broad-band, spectral filters (i.e., gray/neutral density, blue, yellow, and red), which produced similar luminance values for the test stimulus. The VEP N75 and P100 latencies, and VEP amplitude, were recorded. Power spectrum analysis was used to derive the respective powers at each frequency, and peak frequency, for the selected 9-11Hz components of the alpha band. Both N75 and P100 latencies increased with the addition of each filter when compared to baseline. Additionally, each filter numerically reduced intra-session amplitude variability relative to baseline. There were no significant effects on either the mean VEP amplitude or alpha wave parameters. The Intuitive Colorimeter filters significantly increased both N75 and P100 latencies, an effect which is primarily attributable (∼75%) to luminance, and in some cases, specific spectral effects (e.g., blue and red). VEP amplitude and alpha power were not significantly affected. These findings provide an important reference to which either amplitude or power changes in light-sensitive, younger clinical groups can be compared. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
The effect of spectral filters on VEP and alpha-wave responses
Willeford, Kevin T.; Fimreite, Vanessa; Ciuffreda, Kenneth J.
2015-01-01
Purpose Spectral filters are used to treat light sensitivity in individuals with traumatic brain injury (TBI); however, the effect of these filters on normal visual function has not been elucidated. Thus, the current study aimed to determine the effect of spectral filters on objectively-measured visual-evoked potential (VEP) and alpha-wave responses in the visually-normal population. Methods The full-field (15°H × 17°V), pattern-reversal VEP (20′ check size, mean luminance 52 cd/m2) was administered to 20 visually-normal individuals. They were tested with four Intuitive-Colorimeter-derived, broad-band, spectral filters (i.e., gray/neutral density, blue, yellow, and red), which produced similar luminance values for the test stimulus. The VEP N75 and P100 latencies, and VEP amplitude, were recorded. Power spectrum analysis was used to derive the respective powers at each frequency, and peak frequency, for the selected 9–11 Hz components of the alpha band. Results Both N75 and P100 latencies increased with the addition of each filter when compared to baseline. Additionally, each filter numerically reduced intra-session amplitude variability relative to baseline. There were no significant effects on either the mean VEP amplitude or alpha wave parameters. Conclusions The Intuitive Colorimeter filters significantly increased both N75 and P100 latencies, an effect which is primarily attributable (∼75%) to luminance, and in some cases, specific spectral effects (e.g., blue and red). VEP amplitude and alpha power were not significantly affected. These findings provide an important reference to which either amplitude or power changes in light-sensitive, younger clinical groups can be compared. PMID:26293969
An astronomy camera for low background applications in the 1. 0 to 2. 5. mu. m spectral region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaki, S.A.; Bailey, G.C.; Hagood, R.W.
1989-02-01
A short wavelength (1.0-2.5 ..mu..m) 128 x 128 focal plane array forms the heart of this low background astronomy camera system. The camera is designed to accept either a 128 x 128 HgCdTe array for the 1-2.5 ..mu..m spectral region or an InSb array for the 3-5 ..mu..m spectral region. A cryogenic folded optical system is utilized to control excess stray light along with a cold eight-position filter wheel for spectral filtering. The camera head and electronics will also accept a 256 x 256 focal plane. Engineering evaluation of the complete system is complete along with two engineering runs atmore » the JPL Table Mountain Observatory. System design, engineering performance, and sample imagery are presented in this paper.« less
NASA Astrophysics Data System (ADS)
Karaağaç, Dursun; Kürkçüoğlu, Güneş Süheyla; Şenyel, Mustafa; Hökelek, Tuncer
2017-02-01
Three new cadmium(II)-metal(II) cyanide complexes, [Cd(4aepy)2(H2O)2][Ni(CN)4] (1), [Cd(4aepy)2(H2O)2][Pd(CN)4] (2) and [Cd(4aepy)2(H2O)2][Pt(CN)4] (3) [4aepy = 4-(2-aminoethyl)pyridine], have been synthesized and characterized by elemental, thermal, FT-IR and Raman spectral analyses. The crystal structures of 1 and 2 have been determined by single crystal X-ray diffraction technique, in which they crystallize in the monoclinic system and C2/c space group. The M(II) [M(II) = Ni(II), Pd(II) and Pt(II)] ions are coordinated with the carbon atoms of the four cyanide groups in the square planar geometries and the [M(CN)4]2- ions act as counter ions. The Cd(II) ions display an N4O2 coordination sphere with a distorted octahedral geometry, the nitrogen donors belonging to four molecules of the organic 4aepy that act as unidentate ligands and two oxygen atoms from aqua ligands. 3D supramolecular structures of 1 and 2 were occurred by M⋯π and hydrogen bonding (Nsbnd H⋯N and Osbnd H⋯N) interactions. Vibrational assignments of all the observed bands were given and the spectral properties were also supported the crystal structures of the complexes. A possible decompositions of the complexes were investigated in the temperature range 30-800 °C in the static atmosphere.
Structural and molecular docking studies of biologically active mercaptopyrimidine Schiff bases
NASA Astrophysics Data System (ADS)
Kirubavathy, S. Jone; Velmurugan, R.; Karvembu, R.; Bhuvanesh, N. S. P.; Enoch, Israel V. M. V.; Selvakumar, P. Mosae; Premnath, D.; Chitra, S.
2017-01-01
Novel Schiff bases derived from the treatment of mercapto-diamino pyrimidine with two different aldehydes are characterized using elemental analysis, single crystal X-ray diffraction and 1H NMR spectroscopy. The pharmacological action of the synthesized compounds viz., antimicrobial, anticancer and antitubercular activities is studied. The Schiff bases show a very good activity against various test pathogens. DNA and β-CD binding interactions of the compounds are studied using UV-Visible absorption and fluorescence spectral measurements. The binding constants of the compounds towards β-CD are in the order of 103 to 104. Molecular docking is done using MOE program on the 3D structure of the enzymes, viz., human thymidylate synthase complexed with dump and raltitrex, candida albicans N-myristoyltransferasepeptidic inhibitor, catalytic domain of protein kinase pKnb from mycobacterium tuberculosis in complex with mitoxantrone, pare, topoisomerase atpase inhibitor, E. coli and lactobacillus casdihydrofolatereductase. The MIC/IC50 values of the Schiff bases are compared with the glide scores from the molecular docking studies. The number of hydrogen bonding interactions between the Schiff bases and amino acid residues are also reported.
Quantum dots as strain- and metabolism-specific microbiological labels
NASA Technical Reports Server (NTRS)
Kloepfer, J. A.; Mielke, R. E.; Wong, M. S.; Nealson, K. H.; Stucky, G.; Nadeau, J. L.
2003-01-01
Biologically conjugated quantum dots (QDs) have shown great promise as multiwavelength fluorescent labels for on-chip bioassays and eukaryotic cells. However, use of these photoluminescent nanocrystals in bacteria has not previously been reported, and their large size (3 to 10 nm) makes it unclear whether they inhibit bacterial recognition of attached molecules and whether they are able to pass through bacterial cell walls. Here we describe the use of conjugated CdSe QDs for strain- and metabolism-specific microbial labeling in a wide variety of bacteria and fungi, and our analysis was geared toward using receptors for a conjugated biomolecule that are present and active on the organism's surface. While cell surface molecules, such as glycoproteins, make excellent targets for conjugated QDs, internal labeling is inconsistent and leads to large spectral shifts compared with the original fluorescence, suggesting that there is breakup or dissolution of the QDs. Transmission electron microscopy of whole mounts and thin sections confirmed that bacteria are able to extract Cd and Se from QDs in a fashion dependent upon the QD surface conjugate.
Mussel glue protein has an open conformation.
Williams, T; Marumo, K; Waite, J H; Henkens, R W
1989-03-01
Both native glue protein from marine mussels and a synthetic nonhydroxylated analog were analyzed by far-uv CD under a variety of conditions. Analysis of the CD spectra using various models strongly suggest a primarily random coil structure for both forms of the protein, a fact also supported by the absence of spectral change for the glue protein upon dilution into 6 M guanidine hydrochloride. The nonhydroxylated analog, which consists of 20 repeats of the peptide sequence Ala-Lys-Pro-Ser-Tyr-Pro-Pro-Thr-Tyr-Lys, was further characterized by enzyme modification using mushroom tyrosinase. Enzymatic hydroxylation of tyrosines was found to be best fit by a model containing two rate constants, 5.6 (+/- 0.6) X 10(-3) and 7.2 (+/- 0.3) X 10(-2) min-1. At equilibrium, HPLC analysis of digests showed nearly 100% conversion of Tyr-9 and only 15 to 35% conversion of Tyr-5. The Chou and Fasman rules for predicting structure were applied to the repeat sequence listed above. The rules predict the absence of alpha helix and beta pleated sheets in the structure of this peptide. On the other hand, beta turns are predicted to be present with Tyr-5 being in the region of highest probability. These data suggest that the protein in solution has only a small amount of secondary structure.
Clean focus, dose and CD metrology for CD uniformity improvement
NASA Astrophysics Data System (ADS)
Lee, Honggoo; Han, Sangjun; Hong, Minhyung; Kim, Seungyoung; Lee, Jieun; Lee, DongYoung; Oh, Eungryong; Choi, Ahlin; Kim, Nakyoon; Robinson, John C.; Mengel, Markus; Pablo, Rovira; Yoo, Sungchul; Getin, Raphael; Choi, Dongsub; Jeon, Sanghuck
2018-03-01
Lithography process control solutions require more exacting capabilities as the semiconductor industry goes forward to the 1x nm node DRAM device manufacturing. In order to continue scaling down the device feature sizes, critical dimension (CD) uniformity requires continuous improvement to meet the required CD error budget. In this study we investigate using optical measurement technology to improve over CD-SEM methods in focus, dose, and CD. One of the key challenges is measuring scanner focus of device patterns. There are focus measurement methods based on specially designed marks on scribe-line, however, one issue of this approach is that it will report focus of scribe line which is potentially different from that of the real device pattern. In addition, scribe-line marks require additional design and troubleshooting steps that add complexity. In this study, we investigated focus measurement directly on the device pattern. Dose control is typically based on using the linear correlation behavior between dose and CD. The noise of CD measurement, based on CD-SEM for example, will not only impact the accuracy, but also will make it difficult to monitor dose signature on product wafers. In this study we will report the direct dose metrology result using an optical metrology system which especially enhances the DUV spectral coverage to improve the signal to noise ratio. CD-SEM is often used to measure CD after the lithography step. This measurement approach has the advantage of easy recipe setup as well as the flexibility to measure critical feature dimensions, however, we observe that CD-SEM metrology has limitations. In this study, we demonstrate within-field CD uniformity improvement through the extraction of clean scanner slit and scan CD behavior by using optical metrology.
NASA Astrophysics Data System (ADS)
Yoon, J.; von Hoyningen-Huene, W.; Kokhanovsky, A. A.; Vountas, M.; Burrows, J. P.
2012-06-01
Regular aerosol observations based on well-calibrated instruments have led to a better understanding of the aerosol radiative budget on Earth. In recent years, these instruments have played an important role in the determination of the increase of anthropogenic aerosols by means of long-term studies. Only few investigations regarding long-term trends of aerosol optical characteristics (e.g. aerosol optical thickness (AOT) and Ångström exponent (ÅE)) have been derived from ground-based observations. This paper aims to derive and discuss linear trends of AOT (440, 675, 870, and 1020 nm) and ÅE (440-870 nm) using AErosol RObotic NETwork (AERONET) level 2.0 spectral observations. Additionally, temporal trends of coarse- and fine-mode dominant AOTs (CdAOT and FdAOT) have been estimated by applying an aerosol classification based on accurate ÅE and Ångström exponent difference (ÅED). In order to take into account the fact that cloud disturbance is having a significant influence on the trend analysis of aerosols, we introduce a weighted least squares regression depending on two weights: (1) monthly standard deviation (σt) and (2) number of observations per month (nt). Temporal increase of FdAOTs (440 nm) prevails over newly industrializing countries in East Asia (weighted trends; +6.23% yr-1 at Beijing) and active agricultural burning regions in South Africa (+1.89% yr-1 at Mongu). On the other hand, insignificant or negative trends for FdAOTs are detected over Western Europe (+0.25% yr-1 at Avignon and -2.29% yr-1 at Ispra) and North America (-0.52% yr-1 for GSFC and -0.01% yr-1 at MD_Science_Center). Over desert regions, both increase and decrease of CdAOTs (+3.37% yr-1 at Solar_Village and -1.18% yr-1 at Ouagadougou) are observed depending on meteorological conditions.
Fujiki, Michiya; Kawagoe, Yoshifumi; Nakano, Yoko; Nakao, Ayako
2013-06-17
Solvent chirality transfer of (S)-/(R)-limonenes allows the instant generation of optically active PF8P2 aggregates with distinct circular dichroism (CD)/circularly polarized luminescence (CPL) amplitudes with a high quantum yield of 16-20%. The present paper also reports subtle mirror-symmetry-breaking effects in CD-/CPL-amplitude and sign, CD/UV-vis spectral wavelengths, and photodynamics of the aggregates, though the reasons for the anomaly are unsolved. However, these photophysical properties depend on (i) the chemical natures of chiral and achiral molecules when used in solvent quantity, (ii) clockwise and counterclockwise stirring operations, and (iii) the order of addition of limonene and methanol to the chloroform solution.
Origin of the blue shift of the CH stretching band for 2-butoxyethanol in water.
Katsumoto, Yukiteru; Komatsu, Hiroyuki; Ohno, Keiichi
2006-07-26
The blue shift of the isolated CD stretching band of 2-butoxyethanol (C4E1), which is observed for the aqueous solution during the dilution process, has been investigated by infrared (IR) spectroscopy and quantum chemical calculations. Mono-deuterium-labeled C4E1's were employed to remove the severe overlapping among the CH stretching bands. The isolated CD stretching mode of the alpha-methylene in the butoxy group shows a large blue shift, while those of the beta-methylene and methyl groups are not largely shifted. The spectral simulation results for the C4E1/H2O complexes indicate that the large blue shift of the CD stretching band of the butoxy group arises mainly from the hydration of the ether oxygen atom.
Magneto-optical studies of ensembles of semimagnetic self-organized Cd(Mn)Se/Zn(Mn)Se Quantum Dots
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reshina, I. I.; Ivanov, S. V.; Toropov, A. A.
2013-12-04
Ensembles of Cd(Mn)Se/ZnSe and CdSe/Zn(Mn)Se semimagnetic self-organized quantum dots with different Mn content have been studied by photoluminescence and resonant Raman scattering under strong magnetic fields in Faraday and Voigt geometries and with spectral and polarization selective excitation. Electron spin-flip Raman scattering has been observed in Voigt geometry in the structures with large Mn content. Narrow exciton peaks completely σ{sup −}σ{sup +} polarized have been observed under selective excitation in Faraday geometry in the structures with medium and small Mn content. A number of specific effects manifested themselves in the structures with a smallest Mn content where no Zeeman shiftmore » of the photoluminescence bands was observed.« less
Magneto-optical Faraday rotation of semiconductor nanoparticles embedded in dielectric matrices.
Savchuk, Andriy I; Stolyarchuk, Ihor D; Makoviy, Vitaliy V; Savchuk, Oleksandr A
2014-04-01
Faraday rotation has been studied for CdS, CdTe, and CdS:Mn semiconductor nanoparticles synthesized by colloidal chemistry methods. Additionally these materials were prepared in a form of semiconductor nanoparticles embedded in polyvinyl alcohol films. Transmission electron microscopy and atomic force microscopy analyses served as confirmation of nanocrystallinity and estimation of the average size of the nanoparticles. Spectral dependence of the Faraday rotation for the studied nanocrystals and nanocomposites is correlated with a blueshift of the absorption edge due to the confinement effect in zero-dimensional structures. Faraday rotation spectra and their temperature behavior in Mn-doped nanocrystals demonstrates peculiarities, which are associated with s, p-d exchange interaction between Mn²⁺ ions and band carriers in diluted magnetic semiconductor nanostructures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ngu, Thanh T.; Sturzenbaum, Stephen R.; Stillman, Martin J.
The earthworm Lumbricus rubellus has been found to inhabit cadmium-rich soils and accumulate cadmium within its tissues. Two metallothionein (MT) isoforms (1 and 2) have been identified and cloned from L. rubellus. In this study, we address the metalation status, metal coordination, and structure of recombinant MT-2 from L. rubellus using electrospray ionization mass spectrometry (ESI-MS), UV absorption, and circular dichroism (CD) spectroscopy. This is the first study to show the detailed mass and CD spectral properties for the important cadmium-containing earthworm MT. We report that the 20-cysteine L. rubellus MT-2 binds seven Cd{sup 2+} ions. UV absorption and CDmore » spectroscopy and ESI-MS pH titrations show a distinct biphasic demetalation reaction, which we propose results from the presence of two metal-thiolate binding domains. We propose stoichiometries of Cd{sub 3}Cys{sub 9} and Cd{sub 4}Cys{sub 11} based on the presence of 20 cysteines split into two isolated regions of the sequence with 11 cysteines in the N-terminal and 9 cysteines in the C-terminal. The CD spectrum reported is distinctly different from any other metallothionein known suggesting quite different binding site structure for the peptide.« less
NASA Astrophysics Data System (ADS)
Barman, Siti; Barman, Biraj Kumar; Roy, Mahendra Nath
2018-03-01
The supramolecular interaction of metoclopramide hydrochloride (MP) with α-cyclodextrin (α-CD) and β-cyclodextrin (β-CD) has been inspected by ultraviolet-visible (UV-vis) light, infra-red (IR) light, fluorescence and 1H NMR spectroscopy. The formation of an inclusion complex greatly affects the physical-chemical properties of the guest molecules, such as solubility, chemical reactivity and the spectroscopic and electrochemical properties. Thus the changes in the spectral properties and physico-chemical properties confirm the inclusion complex formation. Surface tension, conductivity studies and Job's plot indicate a 1: 1 stoichiometry of the MP:CD host-guest inclusion complexes. The binding/association constants have been evaluated by both UV-Vis and fluorescence spectroscopic study indicating a higher degree of encapsulation for β-cyclodextrin (β-CD). Furthermore, the negative value of thermodynamic parameter (ΔG°) of the host-guest system suggests that the inclusion process proceeded spontaneously at 298.15 K. Based on the NMR data, the plausible mode of interaction of MP:α-CD and MP:β-CD complexes were proposed, which suggested that lipophilic aromatic ring of the MP entered into the cavity of CDs from the wider side, with the amide (sbnd CONH) and methoxy (-OMe) residues inside the CD cavity.
Wavelength-Controlled Photodetector Based on Single CdSSe Nanobelt
NASA Astrophysics Data System (ADS)
Li, Xinmin; Tan, Qiuhong; Feng, Xiaobo; Wang, Qianjin; Liu, Yingkai
2018-06-01
CdSSe nanobelts (NBs) are synthesized by thermal evaporation and then characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), high-resolution electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), photoluminescence (PL), and cathodoluminescence (CL). It is found that the CdSSe NBs have a good morphology and microstructure without defects. CL is sensitive to the defects of CdSSe NBs; thus, we can select single nanobelt with homogeneous CL emission to prepare a detector. Based on it, the photodetector of single CdSSe NB was developed and its photoelectric properties were investigated in detail. It is found that under illumination of white light and at the bias voltage of 1 V, the photocurrent of a single CdSSe nanobelt device is 1.60 × 10-7 A, the dark current is 1.96 × 10-10 A, and the ratio of light current to dark one is 816. In addition, the CdSSe nanobelt detector has high photoelectric performance with spectral responsivity of 10.4 AW-1 and external quantum efficiency (EQE) of 19.1%. Its rise/decay time is about 1.62/4.70 ms. This work offers a novel strategy for design wavelength-controlled photodetectors by adjusting their compositions.
Wavelength-Controlled Photodetector Based on Single CdSSe Nanobelt.
Li, Xinmin; Tan, Qiuhong; Feng, Xiaobo; Wang, Qianjin; Liu, Yingkai
2018-06-07
CdSSe nanobelts (NBs) are synthesized by thermal evaporation and then characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), transmission electron microscopy (TEM), high-resolution electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), photoluminescence (PL), and cathodoluminescence (CL). It is found that the CdSSe NBs have a good morphology and microstructure without defects. CL is sensitive to the defects of CdSSe NBs; thus, we can select single nanobelt with homogeneous CL emission to prepare a detector. Based on it, the photodetector of single CdSSe NB was developed and its photoelectric properties were investigated in detail. It is found that under illumination of white light and at the bias voltage of 1 V, the photocurrent of a single CdSSe nanobelt device is 1.60 × 10 -7 A, the dark current is 1.96 × 10 -10 A, and the ratio of light current to dark one is 816. In addition, the CdSSe nanobelt detector has high photoelectric performance with spectral responsivity of 10.4 AW -1 and external quantum efficiency (EQE) of 19.1%. Its rise/decay time is about 1.62/4.70 ms. This work offers a novel strategy for design wavelength-controlled photodetectors by adjusting their compositions.
Magnetic circular dichroism of CdTe nanoparticles
NASA Astrophysics Data System (ADS)
Malakhovskii, A. V.; Sokolov, A. E.; Tsipotan, A. S.; Zharkov, S. M.; Zabluda, V. N.
2018-04-01
Magnetic circular dichroism (MCD) of water-soluble CdTe nanoparticles was observed in the visible spectral range for the first time. Diameter of nanoparticles varied from 2.3 to 4.5 nm. Absorption and photoluminescence spectra were also recorded. Absorption line at 19400 cm-1 and luminescent line at 18200 cm-1 were observed. Splitting of value 960 cm-1 was revealed in the MCD spectrum. Approximately the same splitting was extracted from the absorption spectrum. The MCD was identified as the temperature independent paramagnetic mixing effect. Nature of the absorption line and of its splitting are discussed.
Structural Investigations of the MnO-Bi3O3-CdO Glass System by IR and Raman Spectroscopies
NASA Astrophysics Data System (ADS)
Ardelean, I.; Todor, Ioana; PǍŞCUŢǍ, P.
Homogeneous glasses are formed in the MnO-Bi3O3-CdO system, up to 50 mol% MnO. For these glasses, IR and Raman spectral measurements are carried out in order to elucidate the local structure. We identify by IR spectroscopy both the structural units BiO3 and BiO6. The Raman investigation confirms the prevalence of BiO6 groups in the glass network for all concentrations. The number of these structural groups progressively increases with MnO content.
2014-01-01
CdTe is an important compound semiconductor for solar cells, and its use in nanowire-based heterostructures may become a critical requirement, owing to the potential scarcity of tellurium. The effects of the CdCl2 heat treatment are investigated on the physical properties of vertically aligned ZnO/CdTe core-shell nanowire arrays grown by combining chemical bath deposition with close space sublimation. It is found that recrystallization phenomena are induced by the CdCl2 heat treatment in the CdTe shell composed of nanograins: its crystallinity is improved while grain growth and texture randomization occur. The presence of a tellurium crystalline phase that may decorate grain boundaries is also revealed. The CdCl2 heat treatment further favors the chlorine doping of the CdTe shell with the formation of chlorine A-centers and can result in the passivation of grain boundaries. The absorption properties of ZnO/CdTe core-shell nanowire arrays are highly efficient, and more than 80% of the incident light can be absorbed in the spectral range of the solar irradiance. The resulting photovoltaic properties of solar cells made from ZnO/CdTe core-shell nanowire arrays covered with CuSCN/Au back-side contact are also improved after the CdCl2 heat treatment. However, recombination and trap phenomena are expected to operate, and the collection of the holes that are mainly photo-generated in the CdTe shell from the CuSCN/Au back-side contact is presumably identified as the main critical point in these solar cells. PMID:24910576
Electronic spectrum of non-tetrahedral acceptors in CdTe:Cl and CdTe:Bi,Cl single crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krivobok, V. S., E-mail: krivobok@lebedev.ru; Moscow Institute of Physics and Technology; Nikolaev, S. N.
2016-02-07
The electronic spectra of complex acceptors in compensated CdTe:Cl, CdTe:Ag,Cl, and CdTe:Bi,Cl single crystals are studied using low-temperature photoluminescence (PL) measurements under both nonresonant and resonant excitation of distant donor–acceptor pairs (DAP). The wavelength modulation of the excitation source combined with the analysis of the differential PL signal is used to enhance narrow spectral features obscured because of inhomogeneous line broadening and/or excitation transfer for selectively excited DAPs. For the well-known tetrahedral (T{sub D}) Ag{sub Cd} acceptor, the energies of four excited states are measured, and the values obtained are shown to be in perfect agreement with the previous data.more » Moreover, splitting between the 2P{sub 3/2} (Γ{sub 8}) and 2S{sub 3/2} (Γ{sub 8}) states is clearly observed for Ag{sub Cd} centers located at a short distance (5–7 nm) from a hydrogen-like donor (Cl{sub Te}). This splitting results from the reduction of the T{sub D} symmetry taking place when the acceptor is a member of a donor–acceptor pair. For the Cl-related complex acceptor with an activation energy of ∼121 meV (A-center), the energies of eight excited states are measured. It is shown that this defect produces low-symmetry central-cell correction responsible for the strong splitting of S-like T{sub D} shells. The energy spectrum of the Bi-related shallow acceptor with an activation energy of ∼36 meV is measured as well. The spectrum obtained differs drastically from the hydrogen-like set of levels, which indicates the existence of repulsive low-symmetry perturbation of the hydrogen-like Coulomb potential. It is also shown that the spectra of selectively excited PL recorded for a macroscopic ensemble of distant donor–acceptor pairs allow one to detect the low symmetry of acceptors of a given type caused by their complex nature or by the Jahn–Teller distortion. This method does not require any additional (external) field and is applicable to acceptors in diverse zinc-blende compound semiconductors.« less
Song, Jun; Yin, Jieyun; Chen, Jiande D Z
2015-12-01
Rectal distension (RD) is known to induce intestinal dysmotility. Few studies were performed to compare effects of RD, colon distension (CD) and duodenal distension (DD) on small bowel motility. This study aimed to investigate effects and underlying mechanisms of distensions in these regions on intestinal motility and slow waves. Eight dogs chronically implanted with a duodenal fistula, a proximal colon fistula, and intestinal serosal electrodes were studied in six sessions: control, RD, CD, DD, RD + guanethidine, and CD + guanethidine. Postprandial intestinal contractions and slow waves were recorded for the assessment of intestinal motility. The electrocardiogram was recorded for the assessment of autonomic functions. (1) Isobaric RD and CD suppressed intestinal contractions (contractile index: 6.0 ± 0.4 with RD vs. 9.9 ± 0.9 at baseline, P = 0.001, 5.3 ± 0.2 with CD vs. 7.7 ± 0.8 at baseline, P = 0.008). Guanethidine at 3 mg/kg iv was able to partially block the effects. (2) RD and CD reduced the percentage of normal intestinal slow waves from 92.1 ± 2.8 to 64.2 ± 3.4 % (P < 0.001) and from 90 ± 2.7 to 69.2 ± 3.7 % (P = 0.01), respectively. Guanethidine could eliminate these inhibitory effects. (3) DD did not induce any changes in small intestinal contractions and slow waves (P > 0.05). (4) The spectral analysis of the heart rate variability showed that both RD and CD increased sympathetic activity (LF) and reduced vagal activity (HF) (P < 0.05). Isobaric RD and CD could inhibit postprandial intestinal motility and impair intestinal slow waves, which were mediated via the sympathetic pathway. However, DD at a site proximal to the measurement site did not seem to impair small intestinal contractions or slow waves.
Tirlapur, Uday K; Mulholland, William J; Bellhouse, Brian J; Kendall, Mark; Cornhill, J Fredrick; Cui, Zhanfeng
2006-10-01
Langerhans cells (LCs) play a sentinel role by initiating both adaptive and innate immune responses to antigens pertinent to the skin. With the discovery of various LCs markers including antibodies to major histocompatibility complex class II (MHC-II) molecules and CD1a, intracellular presence of racket-shaped "Birbeck granules," and very recently Langerin/CD207, LCs can be readily distinguished from other subsets of dendritic cells. Femtosecond two-photon laser scanning microscopy (TPLSM) in recent years has emerged as an alternative to the single photon-excitation based confocal laser scanning microscope (CLSM), particularly for minimally-invasive deep-tissue 3D and 4D vital as well as nonvital biomedical imaging. We have recently combined high resolution two-photon immunofluorescence (using anti MHC-II and Langerin/CD207 antibodies) imaging with microspectroscopy and advanced image-processing/volume-rendering modalities. In this work, we demonstrate the use of this novel state-of-the-art combinational approach to characterize the steady state 3D organization and spectral features of the mouse epidermis, particularly to identify the spatial distribution of LCs. Our findings provide unequivocal direct evidence that, in the mouse epidermis, the MHC-II and mLangerin/CD207 antigens do indeed manifest a high degree of colocalization around the nucleus of the LCs, while in the distal dendritic processes, mLangerin/CD207 antigens are rather sparsely distributed as punctuate structures. This unique possibility to simultaneously visualize high resolution 3D-resolved spatial distributions of two different immuno-reactive antigens, namely MHC-II and mLangerin/CD207, along with the nuclei of LCs and the adjacent epidermal cells can find interesting applications. These could involve aspects associated with pragmatic analysis of the kinetics of LCs migration as a function of immuno-dermatological responses during (1) human Immunodeficiency virus disease progression, (2) vaccination and targeted gene therapy, (3) skin transplantation/plastic surgery, (4) ultraviolet and other radiation exposure, (5) tissue-engineering of 3D skin constructs, as well as in (6) cosmetic industry, to unravel the influence of cosmeceuticals.
Iordache, Sevastiţa; Filip, Maria-Monalisa; Georgescu, Claudia-Valentina; Angelescu, Cristina; Ciurea, Tudorel; Săftoiu, Adrian
2012-06-01
Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). Assessment of tumor vascularity using contrast-enhanced EUS, including analysis of spectral Doppler parameters is possible and feasible in gastric cancer patients. A correlation between measured EUS vascularity and pathological parameters of angiogenesis (MVD and VEGF expression) was found.
Hyperspectral estimation of soil heavy metals in Guanzhong area, Shaanxi province
NASA Astrophysics Data System (ADS)
Liu, Jinbao; Cheng, Jie; Wang, Huanyuan; Tong, Wei; Ma, Zenghui
2017-10-01
In this study, the contents of Cr, Mn, Ni, Cu, and Zn, As, Cd, Hg and Pub in 44 soil samples were collected from Fufeng County, Yangling County and Wugong County, Shaanxi Province and were used as data sources. ASD Field Spec HR (350 ˜ 2500 nm), and then the NOR, MSC and SNV of the reflectance were pretreated, the first deviation, second deviation and reflectance reciprocal logarithmic transformation were carried out. The optimal hyper spectral estimation model of nine heavy metal elements of Cr, Mn, Ni, Cu, and Zn, As, Cd, Hg and Pb was established by regression method. Comparing the reflection characteristics of different heavy metal contents and the effect of different pretreatment methods on the establishment of soil heavy metal spectral inversion model. The results show that: (1) the reflectance spectrum improves the signal-to-noise ratio of the reflectance spectrum after the transformation of NOR, MSC and SNV. Combining differential transformation can improve the information of heavy metal elements in the soil, and use the correlation band energy significantly improve the stability and predictability of the model. (2) The modeling accuracy of the optimal model of nine heavy metal spectra of Cr, Mn, Ni, Cu, and Zn, As, Cd, Hg and Pb by PLSR method were 0.7002, 0.7852, 0.687, 0.8036, 0.8619, 0.5765, 0.5451, 0.9912, and 0.6182.
Application of Timepix3 based CdTe spectral sensitive photon counting detector for PET imaging
NASA Astrophysics Data System (ADS)
Turecek, Daniel; Jakubek, Jan; Trojanova, Eliska; Sefc, Ludek; Kolarova, Vera
2018-07-01
Positron emission tomography (PET) is a nuclear medicine functional imaging technique. It is used in clinical oncology (medical imaging of tumors and the search for metastases), and pre-clinical studies using animals. PET uses small amounts of radioactive materials (radiotracers) and a special photon sensitive camera. Most of these cameras use scintillators with photomultipliers as detectors. However, these detectors have limited energy sensitivity and large pixels. Therefore, the false signal caused by a scattering poses a significant problem. In this work we study properties of position, energy and time sensitive semiconductor detector of Timepix3 type and its applicability for PET measurements. This work presents an initial study and evaluation of two Timepix3 detectors with 2 mm thick CdTe sensors used in simplified geometry for PET imaging. The study is performed on 2 samples - a capillary tube and a cylindrical plexiglass phantom with cavities. Both samples are filled with fluodeoxyglucose (FDG) solution that is used as a radiotracer. The Timepix3 offers better properties compared to conventional detectors - high granularity (55 μm pixel pitch), good energy resolution (1 keV at 60 keV) and sufficient time resolution (1.6 ns). The spectral sensitivity of Timepix3 together with coincidence/anticoincidence technique allows for significant reduction of background signal caused by Compton scattering and internal X-ray fluorescence of Cd and Te.
NASA Astrophysics Data System (ADS)
Nabhan, E.; Abd-Allah, W. M.; Ezz-El-Din, F. M.
Sodium metaphosphate glasses containing divalent metal oxide, ZnO or CdO with composition 50 P2O5 - (50 - x) Na2O - x MO (ZnO, or CdO) where x = 0, 10, 20 (mol%) were prepared by conventional melt method. UV/visible spectroscopy and FTIR spectroscopy are measured before and after exposing to successive gamma irradiation doses (5-80 kGy). The optical absorption spectra results of the samples before irradiation reveal a strong UV absorption band at (∼230 nm) which is related to unavoided iron impurities. The effects of gamma irradiation on the optical spectral properties of the various glasses have been compared. From the optical absorption spectral data, the optical band gap is evaluated. The main structural groups and the influence of both divalent metal oxide and gamma irradiation effect on the structural vibrational groups are realized through IR spectroscopy. The FTIR spectra of γ-irradiated samples are characterized by the stability of the number and position for the main characteristic band of phosphate groups. To better understood the structural changes during γ-irradiation, a deconvolution of FTIR spectra in the range 650-1450 cm-1 is made. The FTIR deconvolution results found evidence that, the changes occurring after gamma irradiation have been related to irradiation induced structural defects and compositional changes.
Broadband Gerchberg-Saxton algorithm for freeform diffractive spectral filter design.
Vorndran, Shelby; Russo, Juan M; Wu, Yuechen; Pelaez, Silvana Ayala; Kostuk, Raymond K
2015-11-30
A multi-wavelength expansion of the Gerchberg-Saxton (GS) algorithm is developed to design and optimize a surface relief Diffractive Optical Element (DOE). The DOE simultaneously diffracts distinct wavelength bands into separate target regions. A description of the algorithm is provided, and parameters that affect filter performance are examined. Performance is based on the spectral power collected within specified regions on a receiver plane. The modified GS algorithm is used to design spectrum splitting optics for CdSe and Si photovoltaic (PV) cells. The DOE has average optical efficiency of 87.5% over the spectral bands of interest (400-710 nm and 710-1100 nm). Simulated PV conversion efficiency is 37.7%, which is 29.3% higher than the efficiency of the better performing PV cell without spectrum splitting optics.
Luczynska, Elzbieta; Niemiec, Joanna; Ambicka, Aleksandra; Adamczyk, Agnieszka; Walasek, Tomasz; Ryś, Janusz; Sas-Korczyńska, Beata
2015-09-01
Contrast-enhanced spectral mammography (CESM) is a novel technique used for detection of tumour vascularity by imaging the moment in which contrast, delivered to the lesion by blood vessels, leaks out of them, and flows out through lymphatic vessels. In our study, we included 174 women for whom spectral mammography was performed for diagnostic purposes. The relationship between enhancement in CESM and blood vessel density (BVD), lymphatic vessel density (LVD) or the percentage of fields with at least one lymphatic vessel (distribution of podoplanin-positive vessels - DPV) and other related parameters was assessed in 55 cases. BVD, LVD and DPV were assessed immunohistochemically, applying podoplanin and CD31/CD34 as markers of lymphatic and blood vessels, respectively. The sensitivity (in detection of malignant lesions) of CESM was 100%, while its specificity - 39%. We found a significant positive correlation between the intensity of enhancement in CESM and BVD (p = 0.007, r = 0.357) and a negative correlation between the intensity of enhancement in CESM and DPV (p = 0.003, r = -0.390). Lesions with the highest enhancement in CESM showed a high number of blood vessels and a low number of lymphatics. 1) CESM is a method characterized by high sensitivity and acceptable specificity; 2) the correlation between CESM results and blood/lymphatic vessel density confirms its utility in detection of tissue angiogenesis and/or lymphangiogenesis.
Status of two-color and large format HgCdTe FPA technology at Raytheon Vision Systems
NASA Astrophysics Data System (ADS)
Smith, E. P. G.; Bornfreund, R. E.; Kasai, I.; Pham, L. T.; Patten, E. A.; Peterson, J. M.; Roth, J. A.; Nosho, B. Z.; De Lyon, T. J.; Jensen, J. E.; Bangs, J. W.; Johnson, S. M.; Radford, W. A.
2006-02-01
Raytheon Vision Systems (RVS) is developing two-color and large format single color FPAs fabricated from molecular beam epitaxy (MBE) grown HgCdTe triple layer heterojunction (TLHJ) wafers on CdZnTe substrates and double layer heterojunction (DLHJ) wafers on Si substrates, respectively. MBE material growth development has resulted in scaling TLHJ growth on CdZnTe substrates from 10cm2 to 50cm2, long-wavelength infrared (LWIR) DLHJ growth on 4-inch Si substrates and the first demonstration of mid-wavelength infrared (MWIR) DLHJ growth on 6-inch Si substrates with low defect density (<1000cm -2) and excellent uniformity (composition<0.1%, cut-off wavelength Δcenter-edge<0.1μm). Advanced FPA fabrication techniques such as inductively coupled plasma (ICP) etching are being used to achieve high aspect ratio mesa delineation of individual detector elements with benefits to detector performance. Recent two-color detectors with MWIR and LWIR cut-off wavelengths of 5.5μm and 10.5μm, respectively, exhibit significant improvement in 78K LW performance with >70% quantum efficiency, diffusion limited reverse bias dark currents below 300pA and RA products (zero field-of-view, +150mV bias) in excess of 1×103 Ωcm2. Two-color 20μm unit-cell 1280×720 MWIR/LWIR FPAs with pixel response operability approaching 99% have been produced and high quality simultaneous imaging of the spectral bands has been achieved by mating the FPA to a readout integrated circuit (ROIC) with Time Division Multiplexed Integration (TDMI). Large format mega pixel 20μm unit-cell 2048×2048 and 25μm unit-cell 2560×512 FPAs have been demonstrated using DLHJ HgCdTe growth on Si substrates in the short wavelength infrared (SWIR) and MWIR spectral range. Recent imaging of 30μm unit-cell 256×256 LWIR FPAs with 10.0-10.7μm 78K cut-off wavelength and pixel response operability as high as 99.7% show the potential for extending HgCdTe/Si technology to LWIR wavelengths.
Basic performance and stability of a CdTe solid-state detector panel.
Tsuchiya, Katsutoshi; Takahashi, Isao; Kawaguchi, Tsuneaki; Yokoi, Kazuma; Morimoto, Yuuichi; Ishitsu, Takafumi; Suzuki, Atsurou; Ueno, Yuuichirou; Kobashi, Keiji
2010-05-01
We have developed a prototype gamma camera system (R1-M) using a cadmium telluride (CdTe) detector panel and evaluated the basic performance and the spectral stability. The CdTe panel consists of 5-mm-thick crystals. The field of view is 134 x 268 mm comprising 18,432 pixels with a pixel pitch of 1.4 mm. Replaceable small CdTe modules are mounted on to the circuit board by dedicated zero insertion force connectors. To make the readout circuit compact, the matrix read out is processed by dedicated ASICs. The panel is equipped with a cold-air cooling system. The temperature and humidity in the panel were kept at 20 degrees C and below 70% relative humidity. CdTe polarization was suppressed by the bias refresh technique to stabilize the detector. We also produced three dedicated square pixel-matched collimators: LEGP (20 mm-thick), LEHR (27 mm-thick), and LEUHR (35 mm-thick). We evaluated their basic performance (energy resolution, system resolution, and sensitivity) and the spectral stability in terms of short-term (several hours of continuous acquisition) and long-term (infrequent measurements over more than a year) activity. The intrinsic energy resolution (FWHM) acquired with Tc-99m (140.5 keV) was 6.6%. The spatial resolutions (FWHM at a distance of 100 mm) with LEGP, LEHR, and LEUHR collimators were 5.7, 4.9, and 4.2 mm, and the sensitivities were 71, 39, and 23 cps/MBq, respectively. The energy peak position and the intrinsic energy resolution after several hours of operation were nearly the same as the values a few minutes after the system was powered on; the variation of the peak position was <0.2%, and that of the resolution was about 0.3%. Infrequent measurements conducted over a year showed that the variations of the energy peak position and the intrinsic energy resolution of the system were at a similar level to those described above. The basic performance of the CdTe-gamma camera system was evaluated, and its stability was verified. It was shown that the camera could be operated daily for several months without calibration.
Shen, Zhu-Rui; Li, Ya-Li; Liu, Jian-Bin; Chen, Ming-Xia; Hou, Feng; Wang, Li-Qun
2012-03-07
Transparent luminescent bulk nanocomposites of polysiloxane (PSO) embedded with semiconductor nanocrystals (NCs) have been fabricated by the direct dispersion of CdS NCs in alkyl-(poly)siloxane (APS) followed by co-polymerization. The non-polar characteristics of the APS precursor are compatible with the CdS NC surface (oleylamine), which allows the direct dispersion of the CdS NCs without the need of any surfactant exchange. Chemical crosslinking of the NC-APS dispersion via hydrosilylation between Si-H and the vinyl group in APS immobilizes the CdS NCs in the polysiloxane network. Net-shaped three-dimensional bulk transparent polysiloxane/CdS NC composites were obtained by liquid casting of the NC-precursor dispersion and chemical crosslinking. The PSO/CdS NC composites show visible luminescence under ultraviolet excitation and the luminescent color is tunable from blue to red by controlling the NC concentration in the composite. Photoluminescence spectral analyses reveal the origin of the luminescence as being from the defect emission of the CdS NCs (550-900 nm) and an emission from the PSO matrix (380-550 nm). The luminescent spectra covered a wide range from the ultraviolet to the near-infrared region. The luminescence of the PSO/CdS NC nanocomposites was stable without any apparent degradation after exposure to air for a long time. This simple direct dispersion process is feasible for the fabrication of luminescent nanocomposites with useful optical properties for potential applications in optics and photoelectron devices.
Shan, Yun; Xu, Jing-Juan; Chen, Hong-Yuan
2011-07-01
This work reports an aptasensor for ultrasensitive detection of thrombin based on remarkably efficient energy-transfer induced electrochemiluminescence (ECL) quenching from CdS:Mn nanocrystals (NCs) film to CdTe QDs-doped silica nanoparticles (CdTe/SiO(2) NPs). CdTe/SiO(2) NPs were synthesized via the Stöber method and showed black bodies' strong absorption in a wide spectral range without excitonic emission, which made them excellent ECL quenchers. Within the effective distance of energy scavenging, the ECL quenching efficiency was dependent on the number of CdTe QDs doped into the silica NPs. Using ca. 200 CdTe QDs doped silica NPs on average of 40 nm in diameter as ECL quenching labels, attomolar detection of thrombin was successfully realized. The protein detection involves a competition binding event, based on thrombin replacing CdTe/SiO(2) NPs labeled probing DNA which is hybridized with capturing aptamer immobilized on a CdS:Mn NCs film modified glassy carbon electrode surface by specific aptamer-protein affinity interactions. It results in the displacement of ECL quenching labels from CdS:Mn NCs film and concomitant ECL signal recovery. Owing to the high-content CdTe QDs in silica NP, the increment of ECL intensity (ΔI(ECL)) and the concentration of thrombin showed a double logarithmic linear correlation in the range of 5.0 aM∼5.0 fM with a detection limit of 1aM. And, the aptasensor hardly responded to antibody, bovine serum albumin (BSA), haemoglobin (Hb) and lysozyme, showing good detection selectivity for thrombin. This long-distance energy scavenging could have a promising application perspective in the detection of biological recognition events on a molecular level.
Measurement of the Circular Dichroism of Electronic Transitions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutherland, J.C.
2010-08-11
This chapter describes the measurement of circular dichroism (CD) for absorption due to transitions between two distinct electronic states. This is distinguished from absorption of lower energy photons, which are associated with changes of only the vibrational modes of the absorber and from the absorption of higher energy photons, which may result in ionizations. From the instrumental viewpoint, the chapter describes the measurement of CD that can be recorded using a photomultiplier or avalanche photodiode to quantify the intensity of a light beam, a photoelastic modulator to periodically alter the beam's polarization, and a monochromator located between the light sourcemore » and the modulator. Using either criterion, the focus is on the spectral domain spanning about a decade in wavelength (photon energy) from roughly 1.2 {micro}m (1 eV {approx} 160 zJ) in the near infrared to 120 nm (10 eV {approx} 1.6 aJ) in the vacuum ultraviolet (VUV). In the near infrared, there is overlap between the domain of electronic and purely vibrational transitions, the use of photomultipliers or avalanche photodiodes versus solid state detectors and dispersive versus Fourier-transform spectrometers. There is also some overlap in the VUV with synchrotron beamlines that use arrays of magnets called 'insertion devices' to cause the emitted synchrotron radiation to be elliptically polarized. To my knowledge, no single spectrometer spans this entire spectral domain discussed here, and the vast majority of laboratory instruments come nowhere close to either the upper or lower limit. However, similar analytical approaches and types of instrumentation are employed throughout this spectral domain and thus are logically treated together. The focus in this chapter is on the measurement of CD resulting from the inherent chirality of the absorbing system. Several spectroscopic methods that are closely related in terms of science or instrumentation are treated in other chapters. These include magnetic circular dichroism (MCD), linear dichroism (LD), optical rotary dispersion (ORD), fluorescence detected circular dichroism (FDCD), and circularly polarized luminescence (CPL). A basic CD instrument of the type described here can be configured by temporary alterations of the sample compartment, an additional or repositioned detector and modified electronics to perform many of the important experiments in the visible and UV regions. These include unpolarized absorption and total fluorescence in addition to most of the experiments mentioned above. Except for absorption, such extensions of the basic technology will not be discussed here. Other reviews of instrumentation related to CD have appeared, some containing information complementary to that included here.« less
NASA Astrophysics Data System (ADS)
Wei, Liqing; Xiao, Xizhong; Wang, Yueming; Zhuang, Xiaoqiong; Wang, Jianyu
2017-11-01
Space-borne hyperspectral imagery is an important tool for earth sciences and industrial applications. Higher spatial and spectral resolutions have been sought persistently, although this results in more power, larger volume and weight during a space-borne spectral imager design. For miniaturization of hyperspectral imager and optimization of spectral splitting methods, several methods are compared in this paper. Spectral time delay integration (TDI) method with high transmittance Integrated Stepwise Filter (ISF) is proposed.With the method, an ISF imaging spectrometer with TDI could achieve higher system sensitivity than the traditional prism/grating imaging spectrometer. In addition, the ISF imaging spectrometer performs well in suppressing infrared background radiation produced by instrument. A compact shortwave infrared (SWIR) hyperspectral imager prototype based on HgCdTe covering the spectral range of 2.0-2.5 μm with 6 TDI stages was designed and integrated. To investigate the performance of ISF spectrometer, a method to derive the optimal blocking band curve of the ISF is introduced, along with known error characteristics. To assess spectral performance of the ISF system, a new spectral calibration based on blackbody radiation with temperature scanning is proposed. The results of the imaging experiment showed the merits of ISF. ISF has great application prospects in the field of high sensitivity and high resolution space-borne hyperspectral imagery.
A hyperspectral X-ray computed tomography system for enhanced material identification
NASA Astrophysics Data System (ADS)
Wu, Xiaomei; Wang, Qian; Ma, Jinlei; Zhang, Wei; Li, Po; Fang, Zheng
2017-08-01
X-ray computed tomography (CT) can distinguish different materials according to their absorption characteristics. The hyperspectral X-ray CT (HXCT) system proposed in the present work reconstructs each voxel according to its X-ray absorption spectral characteristics. In contrast to a dual-energy or multi-energy CT system, HXCT employs cadmium telluride (CdTe) as the x-ray detector, which provides higher spectral resolution and separate spectral lines according to the material's photon-counter working principle. In this paper, a specimen containing ten different polymer materials randomly arranged was adopted for material identification by HXCT. The filtered back-projection algorithm was applied for image and spectral reconstruction. The first step was to sort the individual material components of the specimen according to their cross-sectional image intensity. The second step was to classify materials with similar intensities according to their reconstructed spectral characteristics. The results demonstrated the feasibility of the proposed material identification process and indicated that the proposed HXCT system has good prospects for a wide range of biomedical and industrial nondestructive testing applications.
NASA Astrophysics Data System (ADS)
Masoud, Mamdouh S.; Ali, Alaa E.; Elasala, Gehan S.; Kolkaila, Sherif A.
2018-03-01
Synthesis, physicochemical characterization and thermal analysis of ceftazidime complexes with transition metals (Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II)) were discussed. It's obtained that ceftazidime act as bidentate ligand. From magnetic measurement and spectral data, octahedral structures were proposed for all complexes except for cobalt, nickel and mercury had tetrahedral structural. Hyper chemistry program confirmed binding sites of ceftazidime. Ceftazidime complexes show higher activity than ceftazidime for some strains. From TG and DTA curves the thermal decomposition mechanisms of ceftazidime and their metal complexes were suggested. The thermal decomposition of the complexes ended with the formation of metal oxides as a final product except in case of Hg complex.
Rahman, Md Azizur; Akhtar, Juber
2016-10-01
Phytochemical investigation is very valuable for the ethnomedicinally important plants Bauhinia racemosa Lam (BR) and Cordia dichotoma Linn (CD) used for the cure of variety of ailments. This study was thus designed for phytochemical investigation of BR bark and CD leaves. Phytoconstituents were isolated from the methanolic extracts of the plants by column chromatography using silica gel as stationary phase. The structures had been established on the basis of their physicochemical and spectral data, i.e. IR, (1)H NMR, (13)C NMR and MS. Elution of the columns with different solvents furnished six compounds (1-6) from the methanolic extract of BR bark and three compounds (7-9) from the methanolic extract of CD leaves which were structurally elucidated. The present phytochemical investigation reported several new compounds useful in increasing the existing knowledge of phytoconstituents from BR bark and CD leaves which is very valuable, as these drugs are used in the Indian traditional systems of medicine.
Prabhu, A Antony Muthu; Rajendiran, N
2012-11-01
The absorption and fluorescence spectra of labetalol and pseudoephedrine have been studied in different polarities of solvents and β-cyclodextrin (β-CD). The inclusion complexation with β-CD is investigated by UV-visible, steady state and time resolved fluorescence spectra and PM3 method. In protic solvents, the normal emission originates from a locally excited state and the longer wavelength emission is due to intramolecular charge transfer (TICT). Labetalol forms a 1:2 complex and pseudoephedrine forms 1:1 complex with β-CD. Nanosecond time-resolved studies indicated that both molecules show triexponential decay. Thermodynamic parameters (ΔG, ΔH, ΔS) and HOMO, LUMO orbital investigations confirm the stability of the inclusion complex. The geometry of the most stable complex shows that the aromatic ring is deeply self included inside the β-CD cavity and intermolecular hydrogen bonds were established between host and guest molecules. This suggests that hydrophobic effect and hydrogen bond play an important role in the inclusion process.
NASA Astrophysics Data System (ADS)
Glowacki, David R.; Orr-Ewing, Andrew J.; Harvey, Jeremy N.
2015-07-01
We describe a parallelized linear-scaling computational framework developed to implement arbitrarily large multi-state empirical valence bond (MS-EVB) calculations within CHARMM and TINKER. Forces are obtained using the Hellmann-Feynman relationship, giving continuous gradients, and good energy conservation. Utilizing multi-dimensional Gaussian coupling elements fit to explicitly correlated coupled cluster theory, we built a 64-state MS-EVB model designed to study the F + CD3CN → DF + CD2CN reaction in CD3CN solvent (recently reported in Dunning et al. [Science 347(6221), 530 (2015)]). This approach allows us to build a reactive potential energy surface whose balanced accuracy and efficiency considerably surpass what we could achieve otherwise. We ran molecular dynamics simulations to examine a range of observables which follow in the wake of the reactive event: energy deposition in the nascent reaction products, vibrational relaxation rates of excited DF in CD3CN solvent, equilibrium power spectra of DF in CD3CN, and time dependent spectral shifts associated with relaxation of the nascent DF. Many of our results are in good agreement with time-resolved experimental observations, providing evidence for the accuracy of our MS-EVB framework in treating both the solute and solute/solvent interactions. The simulations provide additional insight into the dynamics at sub-picosecond time scales that are difficult to resolve experimentally. In particular, the simulations show that (immediately following deuterium abstraction) the nascent DF finds itself in a non-equilibrium regime in two different respects: (1) it is highly vibrationally excited, with ˜23 kcal mol-1 localized in the stretch and (2) its post-reaction solvation environment, in which it is not yet hydrogen-bonded to CD3CN solvent molecules, is intermediate between the non-interacting gas-phase limit and the solution-phase equilibrium limit. Vibrational relaxation of the nascent DF results in a spectral blue shift, while relaxation of the post-reaction solvation environment results in a red shift. These two competing effects mean that the post-reaction relaxation profile is distinct from what is observed when Franck-Condon vibrational excitation of DF occurs within a microsolvation environment initially at equilibrium. Our conclusions, along with the theoretical and parallel software framework presented in this paper, should be more broadly applicable to a range of complex reactive systems.
Simultaneous multi-species tracking in live cells with quantum dot conjugates.
Clausen, Mathias P; Arnspang, Eva C; Ballou, Byron; Bear, James E; Lagerholm, B Christoffer
2014-01-01
Quantum dots are available in a range of spectrally separated emission colors and with a range of water-stabilizing surface coatings that offers great flexibility for enabling bio-specificity. In this study, we have taken advantage of this flexibility to demonstrate that it is possible to perform a simultaneous investigation of the lateral dynamics in the plasma membrane of i) the transmembrane epidermal growth factor receptor, ii) the glucosylphospatidylinositol-anchored protein CD59, and iii) ganglioside GM1-cholera toxin subunit B clusters in a single cell. We show that a large number of the trajectories are longer than 50 steps, which we by simulations show to be sufficient for robust single trajectory analysis. This analysis shows that the populations of the diffusion coefficients are heterogeneously distributed for all three species, but differ between the different species. We further show that the heterogeneity is decreased upon treating the cells with methyl-β-cyclodextrin.
In vitro DNA binding studies of therapeutic and prophylactic drug citral.
Alam, Md Fazle; Varshney, Supriya; Khan, Masood Alam; Laskar, Amaj Ahmed; Younus, Hina
2018-07-01
The study of drug-DNA interactions is of great importance, as it paves the way towards the design of better therapeutic agents. Here, the interaction of DNA with a therapeutic and prophylactic drug citral has been studied. We have attempted to ascertain the mode of binding of citral with calf thymus DNA (Ct-DNA) through various biophysical techniques. Analysis of the UV-visible absorbance spectra and fluorescence spectra indicated the formation of a complex between citral and Ct-DNA. Competitive binding assays with ethidium bromide (EB), acridine orange (AO) and Hoechst 33258 reflected that citral possibly intercalates within the Ct-DNA. These observations were further confirmed by circular dichroism (CD) spectral analysis, viscosity measurements, DNA melting and molecular docking studies. This study is expected to contribute to a better understanding of molecular mechanisms of citral, and design of new drugs in the future. Copyright © 2018 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutsenko, E V; Voinilovich, A G; Rzheutskii, N V
2013-05-31
The room temperature laser generation in the yellow-green ({lambda} = 558.5-566.7 nm) spectral range has been demonstrated under optical pumping by a pulsed nitrogen laser of Cd(Zn)Se/ZnSe quantum dot heterostructures. The maximum achieved laser wavelength was as high as {lambda} = 566.7 nm at a laser cavity length of 945 {mu}m. High values of both the output pulsed power (up to 50 W) and the external differential quantum efficiency ({approx}60%) were obtained at a cavity length of 435 {mu}m. Both a high quality of the laser heterostructure and a low lasing threshold ({approx}2 kW cm{sup -2}) make it possible tomore » use a pulsed InGaN laser diode as a pump source. A laser microchip converter based on this heterostructure has demonstrated a maximum output pulse power of {approx}90 mW at {lambda} = 560 nm. The microchip converter was placed in a standard TO-18 (5.6 mm in diameter) laser diode package. (semiconductor lasers. physics and technology)« less
NASA Astrophysics Data System (ADS)
Crupi, V.; Guella, G.; Majolino, D.; Mancini, I.; Rossi, B.; Stancanelli, R.; Venuti, V.; Verrocchio, P.; Viliani, G.
2010-05-01
Solid inclusion complex of the non-steroidal anti-inflammatory drug Ibuprofen (IBP, (2-[4-(2-methylpropyl)phenyl]-propanoic acid) with (2,6-dimethyl)-β-cyclodextrin (diME-β-CD) has been investigated by Fourier transform infrared spectroscopy in attenuated total reflectance geometry (FTIR-ATR spectroscopy) and numerical simulation. The complexation-induced changes in the FTIR-ATR spectrum of IBP have been interpreted by comparison with the theoretical vibrational wavenumbers and IR intensities of dimeric structures of IBP, derived from symmetric hydrogen bonding of the two carboxylic groups, computed by using Density Functional Theory (DFT) calculations. From temperature-dependent studies, the enthalpy change ΔH associated with the binding of IBP with diME-β-CD for 1:1 stoichiometry, in solid phase, has been estimated.
NASA Astrophysics Data System (ADS)
Kartal, Zeki; Yavuz, Abdülkerim
2018-03-01
In this study, the clathrates of fumarate-tetracyanonickel-dioxane, given by the formula M2[(fumarate)Ni(CN)4]·2(1,4-Dioxane) (M = Co, Ni, Cd and Hg), have been obtained for the first time through chemical methods. These clathrates have been characterized by elemental, thermal, FT-IR, and FT-Raman spectroscopies. The parameters of structures of clathrates have been determined by X-ray powder diffraction. The thermal behaviors of these clathrates have been also investigated by thermo-gravimetric analysis (TGA), differential thermal analysis (DTA), and derivative thermal gravimetric analysis (DTG) in the range of 20-900 °C. X-ray powder diffraction data have been recorded at ambient temperature in the 2θ range 5-50°. The FT-IR and FT-Raman spectra of clathrates have been recorded in the region of 4000-400 cm-1 and 4000-100 cm-1, respectively. The results of the spectral and thermal analyses of the newly synthesized clathrates of fumarate-tetracyanonickel-dioxane suggest that these clathrates are new examples of the Hofmann-type dioxane clathrates. In our study, the Hofmann-type dioxane clathrates, which are formed by bounding electrons of oxygen-donor atoms of fumarate ion ligand molecule to transition metal atoms, consist of the corrugated |M-Ni(CN)4|∞ polymeric layers, which are held in parallel through the chain of (-M-fumarate-M-).
Characterization of HgCdTe Films Grown on Large-Area CdZnTe Substrates by Molecular Beam Epitaxy
NASA Astrophysics Data System (ADS)
Arkun, F. Erdem; Edwall, Dennis D.; Ellsworth, Jon; Douglas, Sheri; Zandian, Majid; Carmody, Michael
2017-09-01
Recent advances in growth of Hg1- x Cd x Te films on large-area (7 cm × 7.5 cm) CdZnTe (CZT) substrates is presented. Growth of Hg1- x Cd x Te with good uniformity on large-area wafers is achieved using a Riber 412 molecular beam epitaxy (MBE) tool designed for growth of Hg1- x Cd x Te compounds. The reactor is equipped with conventional CdTe, Te, and Hg sources for achieving uniform exposure of the wafer during growth. The composition of the Hg1- x Cd x Te compound is controlled in situ by employing a closed-loop spectral ellipsometry technique to achieve a cutoff wavelength ( λ co) of 14 μm at 78 K. We present data on the thickness and composition uniformity of films grown for large-format focal-plane array applications. The composition and thickness nonuniformity are determined to be <1% over the area of a 7 cm × 7.5 cm wafer. The films are further characterized by Fourier-transform infrared spectroscopy, optical microscopy, and Hall measurements. Additionally, defect maps show the spatial distribution of defects generated during the epitaxial growth of the Hg1- x Cd x Te films. Microdefect densities are in the low 103 cm-2 range, and void defects are below 500 cm-2. Dislocation densities less than 5 × 105 cm-2 are routinely achieved for Hg1- x Cd x Te films grown on CZT substrates. HgCdTe 4k × 4k focal-plane arrays with 15 μm pitch for astronomical wide-area infrared imagers have been produced using the recently developed MBE growth process at Teledyne Imaging Sensors.
NASA Astrophysics Data System (ADS)
Yao, Qi; You, Bin; Zhou, Shuli; Chen, Meng; Wang, Yujiao; Li, Wei
2014-01-01
The suitable size hydrophobic cavity and monochlorotriazinyl group as a reactive anchor make MCT-β-CD to be widely used in fabric finishing. In this paper, the inclusion complexes of monochlorotriazinyl-beta-cyclodextrin (MCT-β-CD) with cypermethrin (CYPERM) and permethrin (PERM) are synthesized and analyzed by TG/DSC, FT-IR and Raman spectroscopy. TG/DSC reveals that the decomposed temperatures of inclusion complexes are lower by 25-30 °C than that of physical mixtures. DFT calculations in conjunction with FT-IR and Raman spectral analyses are used to study the structures of MCT-β-CD and their inclusion complexes. Four isomers of trisubstituted MCT-β-CD are designed and DFT calculations reveal that 1,3,5-trisubstituted MCT-β-CD has the lowest energy and can be considered as main component of MCT-β-CD. The ground-state geometries, vibrational wavenumbers, IR and Raman intensities of MCT-β-CD and their inclusion complexes were calculated at B3LYP/6-31G (d) level of theory. Upon examining the optimized geometry of inclusion complex, we find that the CYPERM and PERM are inserted into the toroid of MCT-β-CD from the larger opening. The band at 1646 cm-1 in IR and at 1668 cm-1 in Raman spectrum reveals that monochloroazinyl group of MCT-β-CD exists in ketone form but not in anion form. The noticeable IR and Raman shift of phenyl reveals that these two benzene rings of CYPERM and PERM stays inside the cavity of MCT-β-CD and has weak interaction with MCT-β-CD. This spectroscopy conclusion is consistent with theoretical predicted structure.
Wen, Shiya; Li, Miaozi; Yang, Junyu; Mei, Xianglin; Wu, Bin; Liu, Xiaolin; Heng, Jingxuan; Qin, Donghuan; Hou, Lintao; Xu, Wei; Wang, Dan
2017-11-08
CdSe x Te 1-x semiconductor nanocrystals (NCs), being rod-shaped/irregular dot-shaped in morphology, have been fabricated via a simple hot-injection method. The NCs composition is well controlled through varying molar ratios of Se to Te precursors. Through changing the composition of the CdSe x Te 1-x NCs, the spectral absorption of the NC thin film between 570-800 nm is proved to be tunable. It is shown that the bandgap of homogeneously alloyed CdSe x Te 1-x active thin film is nonlinearly correlated with the different compositions, which is perceived as optical bowing. The solar cell devices based on CdSe x Te 1-x NCs with the structure of ITO/ZnO/CdSe/CdSe x Te 1-x /MoO x /Au and the graded bandgap ITO/ZnO/CdSe( w / o )/CdSe x Te 1-x /CdTe/MoO x /Au are systematically evaluated. It was found that the performance of solar cells degrades almost linearly with the increase of alloy NC film thickness with respect to ITO/ZnO/CdSe/CdSe 0.2 Te 0.8 /MoO x /Au. From another perspective, in terms of the graded bandgap structure of ITO/ZnO/CdSe/CdSe x Te 1-x /CdTe/MoO x /Au, the performance is improved in contrast with its single-junction analogues. The graded bandgap structure is proved to be efficient when absorbing spectrum and the solar cells fabricated under the structure of ITO/ZnO/CdSe 0.8 Te 0.2 /CdSe 0.2 Te 0.8 /CdTe/MoO x /Au indicate power conversion efficiency (PCE) of 6.37%, a value among the highest for solution-processed inversely-structured CdSe x Te 1-x NC solar cells. As the NC solar cells are solution-processed under environmental conditions, they are promising for fabricating solar cells at low cost, roll by roll and in large area.
Wen, Shiya; Li, Miaozi; Yang, Junyu; Mei, Xianglin; Wu, Bin; Liu, Xiaolin; Heng, Jingxuan; Hou, Lintao; Xu, Wei; Wang, Dan
2017-01-01
CdSexTe1−x semiconductor nanocrystals (NCs), being rod-shaped/irregular dot-shaped in morphology, have been fabricated via a simple hot-injection method. The NCs composition is well controlled through varying molar ratios of Se to Te precursors. Through changing the composition of the CdSexTe1−x NCs, the spectral absorption of the NC thin film between 570–800 nm is proved to be tunable. It is shown that the bandgap of homogeneously alloyed CdSexTe1−x active thin film is nonlinearly correlated with the different compositions, which is perceived as optical bowing. The solar cell devices based on CdSexTe1−x NCs with the structure of ITO/ZnO/CdSe/CdSexTe1−x/MoOx/Au and the graded bandgap ITO/ZnO/CdSe(w/o)/CdSexTe1−x/CdTe/MoOx/Au are systematically evaluated. It was found that the performance of solar cells degrades almost linearly with the increase of alloy NC film thickness with respect to ITO/ZnO/CdSe/CdSe0.2Te0.8/MoOx/Au. From another perspective, in terms of the graded bandgap structure of ITO/ZnO/CdSe/CdSexTe1−x/CdTe/MoOx/Au, the performance is improved in contrast with its single-junction analogues. The graded bandgap structure is proved to be efficient when absorbing spectrum and the solar cells fabricated under the structure of ITO/ZnO/CdSe0.8Te0.2/CdSe0.2Te0.8/CdTe/MoOx/Au indicate power conversion efficiency (PCE) of 6.37%, a value among the highest for solution-processed inversely-structured CdSexTe1−x NC solar cells. As the NC solar cells are solution-processed under environmental conditions, they are promising for fabricating solar cells at low cost, roll by roll and in large area. PMID:29117132
Accuracy of Td-DFT in the Ultraviolet and Circular Dichroism Spectra of Deoxyguanosine and Uridine.
Miyahara, Tomoo; Nakatsuji, Hiroshi
2018-01-11
Accuracy of the time-dependent density functional theory (Td-DFT) was examined for the ultraviolet (UV) and circular dichroism (CD) spectra of deoxyguanosine (dG) and uridine, using 11 different DFT functionals and two different basis sets. The Td-DFT results of the UV and CD spectra were strongly dependent on the functionals used. The basis-set dependence was observed only for the CD spectral calculations. For the UV spectra, the B3LYP and PBE0 functionals gave relatively good results. For the CD spectra, the B3LYP and PBE0 with 6-311G(d,p) basis gave relatively permissible result only for dG. The results of other functionals were difficult to be used for the studies of the UV and CD spectra, though the symmetry adapted cluster-configuration interaction (SAC-CI) method reproduced well the experimental spectra of these molecules. To obtain valuable information from the theoretical calculations of the UV and CD spectra, the theoretical tool must be able to reproduce correctly both of the intensities and peak positions of the UV and CD spectra. Then, we can analyze the reasons of the changes of the intensity and/or the peak position to clarify the chemistry involved. It is difficult to recommend Td-DFT as such tools of science, at least from the examinations using dG and uridine.
Mm-Wave Spectroscopic Sensors, Catalogs, and Uncatalogued Lines
NASA Astrophysics Data System (ADS)
Medvedev, Ivan; Neese, Christopher F.; De Lucia, Frank C.
2014-06-01
Analytical chemical sensing based on high resolution rotational molecular spectra has been recognized as a viable technique for decades. We recently demonstrated a compact implementation of such a sensor. Future generations of these sensors will rely on automated algorithms for quantification of chemical dilutions based on their spectral libraries, as well as identification of spectral features not present in spectral catalogs. Here we present an algorithm aimed at detection of unidentified lines in complex molecular species based on spectroscopic libraries developed in our previous projects. We will discuss the approaches suitable for data mining in feature-rich rotational molecular spectra. Neese, C.F., I.R. Medvedev, G.M. Plummer, A.J. Frank, C.D. Ball, and F.C. De Lucia, "A Compact Submillimeter/Terahertz Gas Sensor with Efficient Gas Collection, Preconcentration, and ppt Sensitivity." Sensors Journal, IEEE, 2012. 12(8): p. 2565-2574
NASA Astrophysics Data System (ADS)
Mang, Chao-Yong; Liu, Cai-Ping; Liu, Guang-Ming; Jiang, Bei; Lan, Hai; Wu, Ke-Chen; Yan, Ya; Li, Hai-Fei; Yang, Ming-Hui; Zhao, Yu
2015-02-01
A cyclic dipeptide often has the multiple configurations and the abundant conformations. The density functional theory (DFT) method is used to search the preferred conformation of the most probable configuration for cordycedipeptide A isolated from the culture liquid of Cordyceps sinensis. The time-dependent DFT approach is exploited to describe the profile of electronic circular dichroism (CD). The calculated results show that the most probable configuration is 3S6R7S, whose preferred conformation has a negative optical rotation and a positive lowest energy electronic CD band.
Quaia, Emilio; Sozzi, Michele; Gennari, Antonio Giulio; Pontello, Michele; Angileri, Roberta; Cova, Maria Assunta
2016-03-01
To determine whether magnetic resonance enterography (MRE) performed without intravenous contrast injection is diagnostically noninferior to conventional contrast-enhanced MRE (CE-MRE) in patients with Crohn's disease (CD). This was an Institutional Review Board (IRB)-approved retrospective study. Ninety-six patients (52 male and 44 female; 47.18 years ± 13.6) with a diagnosis of CD underwent MRE at 1.5T including T2 -weighted single-shot turbo-spin-echo, T2 -weighted spectral fat presaturation with inversion recovery (SPAIR), T1 -weighted balanced fast-field-echo MR sequences, and CE-MRE consisting in T1 -weighted breath-hold THRIVE 3D MRI sequences after administration of gadobenate dimeglumine (0.2 mL/kg of body weight). Unenhanced MRE, CE-MRE, and unenhanced MRE plus CE-MRE were reviewed in separate sessions with blinding by two readers in consensus, and subsequently by two other readers independently considering a subgroup of 20 patients. Crohn's Disease Endoscopic Index of Severity (CDEIS) and/or histologic analysis of the surgical specimen were considered as reference standards for the assessment of inflammatory activity. Patients revealed prevalently active (n = 55 patients) or quiescent CD (n = 41 patients). The agreement between unenhanced MRE vs. CE-MRE in interpreting active bowel inflammation was 96% (123/128 bowel segments; one-sided 95% confidence interval [CI], >94.4%). Unenhanced MRE vs. CE-MRE vs. unenhanced MRE plus CE-MRE revealed a diagnostic accuracy of 93% [90/96] vs. 92% [88/96] vs. 97% [93/96] (P > 0.05) in the diagnosis of active CD. Interreader agreement was very good for all variables (κ value = 0.8-0.9) except for the measurement of the length of disease (κ value = 0.45). Unenhanced MRE was noninferior to CE-MRE in diagnosing active inflammation in patients with CD. © 2015 Wiley Periodicals, Inc.
He, Jintang; Liu, Yashu; Xie, Xiaolei; Zhu, Thant; Soules, Mary; DiMeco, Francesco; Vescovi, Angelo L.; Fan, Xing; Lubman, David M.
2010-01-01
Despite progress in the treatment of glioblastoma, more than 95% of patients suffering from this disease still die within two years. Recent findings support the belief that cancer stem-like cells are responsible for tumor formation and ongoing growth. Here a method combining lectin microarray and LC-MS/MS was used to discover the cell surface glycoprotein markers of a glioblastoma-derived stem-like cell line. Lectin microarray analysis of cell surface glycans showed that two galactose-specific lectins Trichosanthes kirilowii agglutinin (TKA) and Peanut agglutinin (PNA) could distinguish the stem-like glioblastoma neurosphere culture from a traditional adherent glioblastoma cell line. Agarose-bound TKA and PNA were used to capture the glycoproteins from the two cell cultures, which were analyzed by LC-MS/MS. The glycoproteins were quantified by spectral counting, resulting in the identification of 12 and 11 potential glycoprotein markers from the TKA and PNA captured fractions respectively. Almost all of these proteins were membrane proteins. Differential expression was verified by Western blotting analysis of 6 interesting proteins, including the up-regulated Receptor-type tyrosine-protein phosphatase zeta, Tenascin-C, Chondroitin sulfate proteoglycan NG2, Podocalyxin-like protein 1 and CD90, and the down-regulated CD44. An improved understanding of these proteins may be important for earlier diagnosis and better therapeutic targeting of glioblastoma. PMID:20235609
NASA Astrophysics Data System (ADS)
Nevin, A.; Cesaratto, A.; D'Andrea, C.; Valentini, Gianluca; Comelli, D.
2013-05-01
We present the non-invasive study of historical and modern Zn- and Cd-based pigments with time-resolved fluorescence spectroscopy, fluorescence multispectral imaging and fluorescence lifetime imaging (FLIM). Zinc oxide and Zinc sulphide are semiconductors which have been used as white pigments in paintings, and the luminescence of these pigments from trapped states is strongly dependent on the presence of impurities and crystal defects. Cadmium sulphoselenide pigments vary in hue from yellow to deep red based on their composition, and are another class of semiconductor pigments which emit both in the visible and the near infrared. The Fluorescence lifetime of historical and modern pigments has been measured using both an Optical Multichannel Analyser (OMA) coupled with a Nd:YAG nslaser, and a streak camera coupled with a ps-laser for spectrally-resolved fluorescence lifetime measurements. For Znbased pigments we have also employed Fluorescence Lifetime Imaging (FLIM) for the measurement of luminescence. A case study of FLIM applied to the analysis of the painting by Vincent Van Gogh on paper - "Les Bretonnes et le pardon de Pont-Aven" (1888) is presented. Through the integration of complementary, portable and non-invasive spectroscopic techniques, new insights into the optical properties of Zn- and Cd-based pigments have been gained which will inform future analysis of late 19th] and early 20th C. paintings.
The CD4+/CD8+ Ratio in Pulmonary Tuberculosis: Systematic and Meta-Analysis Article.
Yin, Yongmei; Qin, Jie; Dai, Yaping; Zeng, Fanwei; Pei, Hao; Wang, Jun
2015-02-01
The ratio of CD4+/CD8+ has been used as a clinically index to evaluate patients' immunity. Numerous researchers have studied CD4+/CD8+ ratio in pulmonary tuberculosis (PTB) patients. However, the change of CD4+/CD8+ ratio remains controversial. We present a meta-analysis of 15 case-control studies to identify the change of CD4+/CD8+ ratio in PTB patients. We assessed heterogeneity of effect estimates within each group using I(2) test. Subgroup analysis was performed to explore the potential source of heterogeneity. To investigate further the potential publication bias, we visually examined the funnel plots. For robustness of results, we performed sensitivity analysis by removing studies. Data entry and analyses were carried out with RevMan 5.2 (The Nordic Cochrane Centre). Twelve peripheral blood studies were categorized into two subgroups. Eight studies presented a significant decrease of CD4+/CD8+ ratio in PTB cases compared to healthy subjects (SMD: -0.45; 95% CI -0.65--0.25; I(2) = 7%). Other four studies researched on the newly diagnosed patients presented a more seriously and significantly decrease (SMD: -2.17; 95% CI -2.61--1.74; I(2) = 37%). The pooled analysis of bronchoalveolar lavage fluid (BALF) studies showed a significant increase of CD4+/CD8+ ratio using Flow Cytometry (FCM) (SMD: 4.75; 95% CI 3.44-6.05; I(2) =0%). The present meta-analysis indicated that there was a synthetic evidence for the reduced CD4+/CD8+ ratio in peripheral blood of PTB patients, especially newly diagnosed cases. However, the CD4+/CD8+ ratio in BALF was increased using method of FCM.
Mini Compton Camera Based on an Array of Virtual Frisch-Grid CdZnTe Detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Wonho; Bolotnikov, Aleksey; Lee, Taewoong
In this study, we constructed a mini Compton camera based on an array of CdZnTe detectors and assessed its spectral and imaging properties. The entire array consisted of 6×6 Frisch-grid CdZnTe detectors, each with a size of 6×6 ×15 mm 3. Since it is easier and more practical to grow small CdZnTe crystals rather than large monolithic ones, constructing a mosaic array of parallelepiped crystals can be an effective way to build a more efficient, large-volume detector. With the fully operational CdZnTe array, we measured the energy spectra for 133Ba -, 137Cs -, 60Co-radiation sources; we also located these sourcesmore » using a Compton imaging approach. Although the Compton camera was small enough to hand-carry, its intrinsic efficiency was several orders higher than those generated in previous researches using spatially separated arrays, because our camera measured the interactions inside the CZT detector array, wherein the detector elements were positioned very close to each other. Lastly, the performance of our camera was compared with that based on a pixelated detector.« less
2014-01-01
Molybdenum disulfide (MoS2)/cadmium sulfide (CdS) heterojunction solar cells were successfully synthesized via chemical bath deposition (CBD) and chemical vapor deposition (CVD). The as-grown CdS film on a fluorine tin oxide (FTO) substrate deposited by CBD is continuous and compact. The MoS2 film deposited by CVD is homogeneous and continuous, with a uniform color and a thickness of approximately 10 nm. The optical absorption range of the MoS2/CdS heterojunction covers the visible and near-infrared spectral regions of 350 to 800 nm, which is beneficial for the improvement of solar cell efficiency. Moreover, the MoS2/CdS solar cell exhibits good current-voltage (I-V) characteristics and pronounced photovoltaic behavior, with an open-circuit voltage of 0.66 V and a short-circuit current density of 0.227 × 10-6 A/cm2, comparable to the results obtained from other MoS2-based solar cells. This research is critical to investigate more efficient and stable solar cells based on graphene-like materials in the future. PMID:25593552
Tunable single and double emission semiconductor nanocrystal quantum dots: a multianalyte sensor
NASA Astrophysics Data System (ADS)
Ratnesh, Ratneshwar Kumar; Singh Mehata, Mohan
2018-07-01
We have prepared stable colloidal CdTe and CdTe/ZnS core–shell quantum dots (QDs) using hot injection chemical route. The developed CdTe QDs emit tunable single and dual photoluminescence (PL) bands, originating from the direct band edge and the surface state of QDs, as evident by the steady-state and time-resolved spectroscopy. The developed CdTe and CdTe/ZnS QDs act as optical sensors for the detection of metal ions (e.g., Fe2+ and Pb2+) in the feed water. The PL quenching in the presence of analytes has been examined by both the steady-state and time-resolved PL spectroscopy. The linear Stern–Volmer (S–V) plots obtained for PL intensity and lifetime as a function of metal ion concentration demonstrates the diffusion-mediated collisional quenching as a dominant mechanism together with the possibility of fluorescence resonance energy transfer. Thus, the prepared core and core–shell QDs which cover a broad spectral range of white light with high quantum yield (QY) are highly sensitive to the detection of metal ions in feed water and are also important for biological applications (Ratnesh and Mehata 2017 Spectrochim. Acta A: Mol. Biomol. Spectro. 179 201–10).
Mini Compton Camera Based on an Array of Virtual Frisch-Grid CdZnTe Detectors
Lee, Wonho; Bolotnikov, Aleksey; Lee, Taewoong; ...
2016-02-15
In this study, we constructed a mini Compton camera based on an array of CdZnTe detectors and assessed its spectral and imaging properties. The entire array consisted of 6×6 Frisch-grid CdZnTe detectors, each with a size of 6×6 ×15 mm 3. Since it is easier and more practical to grow small CdZnTe crystals rather than large monolithic ones, constructing a mosaic array of parallelepiped crystals can be an effective way to build a more efficient, large-volume detector. With the fully operational CdZnTe array, we measured the energy spectra for 133Ba -, 137Cs -, 60Co-radiation sources; we also located these sourcesmore » using a Compton imaging approach. Although the Compton camera was small enough to hand-carry, its intrinsic efficiency was several orders higher than those generated in previous researches using spatially separated arrays, because our camera measured the interactions inside the CZT detector array, wherein the detector elements were positioned very close to each other. Lastly, the performance of our camera was compared with that based on a pixelated detector.« less
Hughes, Shantelle I; Dasary, Samuel S R; Singh, Anant K; Glenn, Zachery; Jamison, Hakim; Ray, Paresh C; Yu, Hongtao
2013-03-01
Hyper Rayleigh Scattering (HRS) and absorption spectral assays using surface-modified gold nanoparticles (AuNP) have been developed for sensitive and selective detection of trivalent chromium (Cr 3+ ) from other metal ions including hexavalent chromium (as Cr 2 O 7 2- ). Gold nanoparticles of 13 nm, covalently attached with 5,5'-dithio- bis -(2-nitrobenzoic acid) (AuNP-DTNBA), is used as a probe for both the absorption and HRS assays. AuNP-DTNBA is able to detect Cr 3+ at 20 ppb level at pH 6.0 using absorption spectral change of the AuNP-DTNBA. Visible color change can be observed when mixed with 250 ppb of Cr 3+ , while there is no color change when mixed with 2 ppm level of some of the most common metal ions such as Cr 2 O 7 2- , Hg 2+ , Ba 2+ , Fe 3+ , Pb 2+ , Na + , Zn 2+ , Cd 2+ , Co 2+ , Mn 2+ , Ca 2+ , and Ni 2+ . However, a color change is observed when mixed with Ni 2+ , Zn 2+ , and Cd 2+ at a concentration higher than 2 ppm. The detection limit for the HRS assay is on a remarkable 25 ppt level, and there is no detectable HRS signal at 2 ppm level for Cr 2 O 7 2- , Hg 2+ , Ba 2+ , Fe 3+ , Pb 2+ , Na + , Zn 2+ , Cd 2+ , Co 2+ , Mn 2+ , Ca 2+ , and Ni 2+ .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taoufyq, A.; Laboratoire Matériaux et Environnement LME, Faculté des Sciences, Université Ibn Zohr, BP 8106, Cité Dakhla, Agadir; CEA, DEN, Département d'Etudes des Réacteurs, Service de Physique Expérimentale, Laboratoire Dosimétrie Capteurs Instrumentation, 13108 Saint-Paul-lez-Durance
2015-10-15
Highlights: • Luminescence can be modified by chemical substitution in solid solutions Ca{sub 1−x}Cd{sub x}WO{sub 4}. • The various emission spectra (charge transfer) were obtained under X-ray excitation. • Scheelite or wolframite solid solutions presented two types of emission spectra. • A luminescence component depended on cadmium substitution in each solid solution. • A component was only characteristic of oxyanion symmetry in each solid solution. - Abstract: We have investigated the chemical substitution effects on the luminescence properties under X-ray excitation of the solid solutions Ca{sub (1−x)}Cd{sub (x)}WO{sub 4} with 0 ≤ x ≤ 1. Two types of wide spectralmore » bands, associated with scheelite-type or wolframite-type solid solutions, have been observed at room temperature. We decomposed each spectral band into several spectral components characterized by energies and intensities varying with composition x. One Gaussian component was characterized by an energy decreasing regularly with the composition x, while the other Gaussian component was only related to the tetrahedral or octahedral configurations of tungstate groups WO{sub 4}{sup 2−} or WO{sub 6}{sup 6−}. The luminescence intensities exhibited minimum values in the composition range x < 0.5 corresponding to scheelite-type structures, then, they regularly increased for cadmium compositions x > 0.5 corresponding to wolframite-type structures.« less
A staggered-grid convolutional differentiator for elastic wave modelling
NASA Astrophysics Data System (ADS)
Sun, Weijia; Zhou, Binzhong; Fu, Li-Yun
2015-11-01
The computation of derivatives in governing partial differential equations is one of the most investigated subjects in the numerical simulation of physical wave propagation. An analytical staggered-grid convolutional differentiator (CD) for first-order velocity-stress elastic wave equations is derived in this paper by inverse Fourier transformation of the band-limited spectrum of a first derivative operator. A taper window function is used to truncate the infinite staggered-grid CD stencil. The truncated CD operator is almost as accurate as the analytical solution, and as efficient as the finite-difference (FD) method. The selection of window functions will influence the accuracy of the CD operator in wave simulation. We search for the optimal Gaussian windows for different order CDs by minimizing the spectral error of the derivative and comparing the windows with the normal Hanning window function for tapering the CD operators. It is found that the optimal Gaussian window appears to be similar to the Hanning window function for tapering the same CD operator. We investigate the accuracy of the windowed CD operator and the staggered-grid FD method with different orders. Compared to the conventional staggered-grid FD method, a short staggered-grid CD operator achieves an accuracy equivalent to that of a long FD operator, with lower computational costs. For example, an 8th order staggered-grid CD operator can achieve the same accuracy of a 16th order staggered-grid FD algorithm but with half of the computational resources and time required. Numerical examples from a homogeneous model and a crustal waveguide model are used to illustrate the superiority of the CD operators over the conventional staggered-grid FD operators for the simulation of wave propagations.
Multiwavelength study of accretion-powered pulsars
NASA Astrophysics Data System (ADS)
Nespoli, Elisa
2010-11-01
This thesis consists in a multi-frequency approach to High Mass X-ray Binaries (HMXBs), using infrared and X-ray data. On one side, the project aimed at the identification and characterization of IR counterparts to obscured HMXBs in the Scutum and Norma inner galactic arms. The identification of optical/IR counterparts to HMXBs is a necessary step to undertake detailed studies of these systems. With data limited to the high-energy range, the understanding of their complex structure and dynamics cannot be complete. In the last years, INTEGRAL has revealed the presence of an important population of heavily absorbed HMXBs in the Scutum and Norma regions, virtually unobservable below 4 keV. Optical counterparts to these obscured sources are hardly observable, due to the high interstellar extinction. Candidate counterparts to HMXBs were selected by means of a photometric search for emission-line stars in the error boxes of the X-ray sources detected by INTEGRAL. With this objective, I built up (Brγ-K)-(H-K) and (HeI-K)-(H-K) IR color-color diagrams, in which emission-line stars are expected to show up below the absorption-line stars sequence. I applied this technique to search for counterparts to Be/XRBs, whose transient nature prevents the counterpart identification with follow-up X-ray observations with high spatial resolution. For each field, one to four candidate counterparts were identified. I also took spectra of proposed counterparts. The confirmation and spectral classifications of the systems led to unveil the nature of nine INTEGRAL objects. On the other hand, this work intended to provide for the first time a systematic study of four Be/XRBs during giant (type II) outbursts. I employed RXTE data, applying the three techniques of color-color/hardness-intensity diagrams (CD/HID), spectral fitting and Fourier power-spectral analysis, simultaneously, and using the retrieved results and correlations to try to define and characterize spectral states for this class of systems. In this way I followed both a model-independent (CD/HID) and model-dependent approach (spectral fits) to investigate the rapid aperiodic variability as a function of spectral sates in HMXBs. I obtained lightcurves, energy and power spectra for a total number of 320 observations. From X-ray colors, spectral and timing fitting, I clearly identified in all the four systems two different spectral states, i.e. the Diagonal Branch (DB) and Horizontal Branch (HB). The HB corresponds to a lower-flux state, with larger rms than the DB. Also, the power-law photon index decreases with flux in the HB, while stays constant or increases in the DB. The HB shows lower characteristic frequencies of the noise components than in the DB. The cyclotron resonant scattering features are generally associated with the DB, while absent or weaker during the DB. We showed how the transition between the two states may correspond to the transition from the standing shock emission to the thermal mound emission due to the turning point from super-Eddington luminosity regime (DB) to sub-Eddington luminosity regime (HB). From color, spectral and timing point of view, differences among systems easily distinguishes two subgroups, with the slower pulsars, KS 1947+300 and EXO2030+375, on one side, and the faster ones, 4U 0115+63 and V 0332+53, on the other. The first group is characterized by softer spectra in the HB compared with the other systems. Hysteresis is not observed in the slower pulsars, while it is evident in V 0332+53 and 4U 0115+63. Cyclotron resonant scattering features are crucial in the spectral shape of V 0332+53 and 4U 0115+63, where also a harmonic is observed in the 3-30 keV energy range. They are instead absent or very weak in the first group. According to timing features, a strong difference between the two groups is the presence of QPOs in the faster pulsars.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kosyachenko, L. A., E-mail: lakos@chv.ukrpack.net; Lytvynenko, V. Yu.; Maslyanchuk, O. L.
2016-04-15
Optical and recombination losses in a Cu(In,Ga)Se{sub 2} thin-film solar cell with a band gap of 1.36–1.38 eV are theoretically analyzed. The optical transmittance of the ZnO and CdS layers through which the radiation penetrates into the absorbing layer is determined. Using optical constants, the optical loss caused by reflection at the interfaces (7.5%) and absorption in the ZnO and CdS layers (10.2%) are found. To calculate the recombination loss, the spectral distribution of the quantum efficiency of CdS/CuIn{sub 1–x}Ga{sub x}Se{sub 2} is investigated. It is demonstrated that, taking the drift and diffusion components of recombination at the front andmore » rear surfaces of the absorber into account, the quantum efficiency spectra of the investigated solar cell can be analytically described in detail. The real parameters of the solar cell are determined by comparing the calculated results and experimental data. In addition, the losses caused by the recombination of photogenerated carriers at the front and rear surfaces of the absorbing layer (1.8% and <0.1%, respectively), at its neutral part (7.6%), and in the space-charge region of the p–n heterojunction (1.0%) are determined. A correction to the parameters of Cu(In,Ga)Se{sub 2} is proposed, which enhances the charge-accumulation efficiency.« less
Han, Zhi-zhong; Ren, Li-li; Pan, Hai-bo; Li, Chun-yan; Chen, Jing-hua; Chen, Jian-zhong
2015-11-01
In this work, cadmium nitrate hexahydrate [Cd(NO₃)₂ · 6H₂O] is as a source of cadmium, zinc nitrate [Zn(NO₃)₂] as a source of zinc source, and NaHSe as a source of selenium which was prepared through reducing the elemental selenium with sodium borohydride (NaBH₄). Then water-soluble Cd₁₋xZnxSe ternary quantum dots with different component were prepared by colloid chemistry. The as-prepared Cd₁₋xZnx Se ternary quantum dots exhibit stable fluorescent property in aqueous solution, and can still maintain good dispersivity at room temperature for four months. Powder X-ray diffraction (XRD) and high resolution transmission electron microscope (HRTEM) were used to analyze crystal structure and morphology of the prepared Cd₁₋xZnxSe. It is found that the as-prepared ternary quantum dots are cubic phase, show as sphere, and the average of particle size is approximate 4 nm. The spectral properties and energy band structure of the as-prepared ternary quantum dots were modulated through changing the atom ratio of elements Zn and Cd. Compared with binary quantum dots CdSe and ZnSe, the ultraviolet-visible (UV-Visible) absorption spectrum and fluorescence (FL) emission spectrum of ternary quantum dots are both red-shift. The composites (Cd₀.₅ Zn₀.₅ Se@TNTs) of Cd₀.₅ Zn₀.₅ Se ternary quantum dots and TiO₂ nanotubes (TNTs) were prepared by directly immerging TNTs into quantum dots dispersive solution for 5 hours. TEM image shows that the Cd₀.₅ Zn₀.₅ Se ternary quantum dots were closely combined to nanotube surface. The infrared spectra show that the Ti-Se bond was formed between Cd₀.₅ Zn₀.₅ Se ternary quantum dots and TiO₂ nanotubes, which improve the stability of the composite. Compared to pristine TNTs, UV-Visible absorption spectrum of the composites is significantly enhanced in the visible region of light. And the absorption band edge of Cd₀.₅Zn₀.₅ Se@TNTs red-shift from 400 to 700 nm. The recombination of the photogenerated electron-hole pairs was restrained with the as-prepared ternary quantum dots. Therefore, the visible-light photocatalytic efficiency was greatly improved. After visible-light irradiation for 60 min, the degradation of Cd₀.₅ Zn₀.₅ Se@TNTs photocatalysts for RhB is nearly 100%, which is about 3. 3 times of that of pristine TNTs and 2. 5 times of that of pure Cd₀.₅ Zn₀.₅ Se ternary quantum dots, respectively.
Early photoreceptor outer segment loss and retinoschisis in Cohen syndrome.
Uyhazi, Katherine E; Binenbaum, Gil; Carducci, Nicholas; Zackai, Elaine H; Aleman, Tomas S
2018-06-01
To describe early structural and functional retinal changes in a patient with Cohen syndrome. A 13-month-old Caucasian girl of Irish and Spanish ancestry was noted to have micrognathia and laryngomalacia at birth, which prompted a genetic evaluation that revealed biallelic deletions in COH1 (VPS13B) (a maternally inherited 60-kb deletion involving exons 26-32 and a paternally inherited 3.5-kb deletion within exon 17) consistent with Cohen syndrome. She underwent a complete ophthalmic examination, full-field flash electroretinography and retinal imaging with spectral domain optical coherence tomography. Central vision was central, steady, and maintained. There was bilateral myopic astigmatic refractive error. Fundus exam was notable for dark foveolar pigmentation, but no obvious abnormalities of either eye. Spectral domain optical coherence tomography cross sections through the fovea revealed a normal appearing photoreceptor outer nuclear layer but loss of the interdigitation signal between the photoreceptor outer segments and the apical retinal pigment epithelium. Retinoschisis involving the inner nuclear layer of both eyes and possible ganglion cell layer thinning were also noted. There was a detectable electroretinogram with similarly reduced amplitudes of rod- (white, 0.01 cd.s.m -2 ) and cone-mediated (3 cd.s.m -2 , 30 Hz) responses. Photoreceptor outer segment abnormalities and retinoschisis may represent the earliest structural retinal change detected by spectral domain optical coherence tomography in patients with Cohen syndrome, suggesting a complex pathophysiology with primary involvement of the photoreceptor cilium and disorganization of the structural integrity of the inner retina.
[Determination of protein by CdS quantum dot fluorometry].
Hu, Wei-Ping; Jiao, Man; Dong, Xue-Zhi; Wang, Xin
2011-02-01
Determination of protein content by fluorometry was carried out. In this experiment, CdS quantum dots (QDs) that have special spectral properties were prepared with sodium hexametaphosphate as stabilizer and mercapto acetic acid as modifier by hydrothermal synthesis method. Based on the increase in fluorescence intensity after CdS reacted with bovine serum albumin (BSA), a new method for the determination of protein was established. Results show that the fluorescence intensity of system has a good linear relationship with the concentration of BSA in the range of 0.001 43-0.250 mg x mL(-1), and the linear equation was F = 5 444.301 03 + 43.327 39c, relation coefficient (r) was 0.996 6, the limit of detection was 0.001 4 mg x mL(-1). The method has been used for the determination of protein in milk and egg, and compared with the standard method (biuret method), and the results were satisfactory.
Linear Mode HgCdTe Avalanche Photodiodes for Photon Counting Applications
NASA Technical Reports Server (NTRS)
Sullivan, William, III; Beck, Jeffrey; Scritchfield, Richard; Skokan, Mark; Mitra, Pradip; Sun, Xiaoli; Abshire, James; Carpenter, Darren; Lane, Barry
2015-01-01
An overview of recent improvements in the understanding and maturity of linear mode photon counting with HgCdTe electron-initiated avalanche photodiodes is presented. The first HgCdTe LMPC 2x8 format array fabricated in 2011 with 64 micron pitch was a remarkable success in terms of demonstrating a high single photon signal to noise ratio of 13.7 with an excess noise factor of 1.3-1.4, a 7 ns minimum time between events, and a broad spectral response extending from 0.4 micron to 4.2 micron. The main limitations were a greater than 10x higher false event rate than expected of greater than 1 MHz, a 5-7x lower than expected APD gain, and a photon detection efficiency of only 50% when greater than 60% was expected. This paper discusses the reasons behind these limitations and the implementation of their mitigations with new results.
Norman, Patrick; Linares, Mathieu
2014-09-01
The chirality of stacked weakly interacting π-systems was interpreted in terms of Frenkel exciton states and the formation of excitonic circular dichroism (CD) bands was monitored for ethylene stacks of varying sizes. Convergence of CD bands with respect to the system size was observed for stacks involving around 10 molecules. By means of rotation around the C-C double bond in ethylene, chirality was induced in the monomeric system and which was shown to dominate the spectral responses, even for polymer aggregates. In helical assemblies of chiral entities, there will always be a mix of excitonic and monomeric contributions to the CD signal and it is demonstrated that the complex polarization propagator approach in combination with Density Functional Theory is a suitable method to address this situation. © 2014 Wiley Periodicals, Inc.
CD and 31P NMR studies of tachykinin and MSH neuropeptides in SDS and DPC micelles
NASA Astrophysics Data System (ADS)
Schneider, Sydney C.; Brown, Taylor C.; Gonzalez, Javier D.; Levonyak, Nicholas S.; Rush, Lydia A.; Cremeens, Matthew E.
2016-02-01
Secondary structural characteristics of substance P (SP), neurokinin A (NKA), neurokinin B (NKB), α-melanocyte stimulating hormone peptide (α-MSH), γ1-MSH, γ2-MSH, and melittin were evaluated with circular dichroism in phosphite buffer, DPC micelles, and SDS micelles. CD spectral properties of γ1-MSH and γ2-MSH as well as 31P NMR of DPC micelles with all the peptides are reported for the first time. Although, a trend in the neuropeptide/micelle CD data appears to show increased α-helix content for the tachykinin peptides (SP, NKA, NKB) and increased β-sheet content for the MSH peptides (α-MSH, γ1-MSH, γ2-MSH) with increasing peptide charge, the lack of perturbed 31P NMR signals for all neuropeptides could suggest that the reported antimicrobial activity of SP and α-MSH might not be related to a membrane disruption mode of action.
NASA Technical Reports Server (NTRS)
Parker, Bradford H.; Stahle, C. M.; Barthelmy, S. D.; Parsons, A. M.; Tueller, J.; VanSant, J. T.; Munoz, B. F.; Snodgrass, S. J.; Mullinix, R. E.
1999-01-01
One of the critical challenges for large area cadmium zinc telluride (CdZnTe) detector arrays is obtaining material capable of uniform imaging and spectroscopic response. Two complementary nondestructive techniques for characterizing bulk CdZnTe have been developed to identify material with a uniform response. The first technique, infrared transmission imaging, allows for rapid visualization of bulk defects. The second technique, x-ray spectral mapping, provides a map of the material spectroscopic response when it is configured as a planar detector. The two techniques have been used to develop a correlation between bulk defect type and detector performance. The correlation allows for the use of infrared imaging to rapidly develop wafer mining maps. The mining of material free of detrimental defects has the potential to dramatically increase the yield and quality of large area CdZnTe detector arrays.
Simulation of Small-Pitch HgCdTe Photodetectors
NASA Astrophysics Data System (ADS)
Vallone, Marco; Goano, Michele; Bertazzi, Francesco; Ghione, Giovanni; Schirmacher, Wilhelm; Hanna, Stefan; Figgemeier, Heinrich
2017-09-01
Recent studies indicate as an important technological step the development of infrared HgCdTe-based focal plane arrays (FPAs) with sub-wavelength pixel pitch, with the advantage of smaller volume, lower weight, and potentially lower cost. In order to assess the limits of pixel pitch scaling, we present combined three-dimensional optical and electrical simulations of long-wavelength infrared HgCdTe FPAs, with 3 μm, 5 μm, and 10 μm pitch. Numerical simulations predict significant cavity effects, brought by the array periodicity. The optical and electrical contributions to spectral inter-pixel crosstalk are investigated as functions of pixel pitch, by illuminating the FPAs with Gaussian beams focused on the central pixel. Despite the FPAs being planar with 100% pixel duty cycle, our calculations suggest that the total crosstalk with nearest-neighbor pixels could be kept acceptably small also with pixels only 3 μ m wide and a diffraction-limited optical system.
Barraza-Garza, Guillermo; Castillo-Michel, Hiram; de la Rosa, Laura A.; Martinez-Martinez, Alejandro; Pérez-León, Jorge A.; Cotte, Marine; Alvarez-Parrilla, Emilio
2016-01-01
The protective effect of different polyphenols, catechin (Cat), quercetin (Qc) (flavonoids), gallic acid (GA), caffeic acid (CfA), chlorogenic acid (ChA) (phenolic acids), and capsaicin (Cap), against H2O2-induced oxidative stress was evaluated in rat enterocytes using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) Spectroscopy and Fourier Transform Infrared Microspectroscopy (FTIRM), and results were compared to standard lipid peroxidation techniques: conjugated dienes (CD) and Thiobarbituric Acid Reactive Substances (TBARS). Analysis of ATR-FTIR and FTIRM spectral data allowed the simultaneous evaluation of the effects of H2O2 and polyphenols on lipid and protein oxidation. All polyphenols showed a protective effect against H2O2-induced oxidative stress in enterocytes, when administered before or after H2O2. Cat and capsaicin showed the highest protective effect, while phenolic acids had weaker effects and Qc presented a mild prooxidative effect (IR spectral profile of biomolecules between control and H2O2-treated cells) according to FTIR analyses. These results demonstrated the viability to use infrared spectroscopy to evaluate the oxidant and antioxidant effect of molecules in cell systems assays. PMID:27213031
NASA Astrophysics Data System (ADS)
Bouhdada, M.; EL Amane, M.
2017-12-01
The hydrazodye (L) [disodium (7-hydroxyl-8-phenylazo-1,3-naphthalenedisulfonate)] is prepared and characterized by infrared 1H,13C, NMR and UV-visible spectra. The spectral data of the ligand (L) existing predominantly in the hydrazones form. Reaction of the hydrazodye (L) with Cd2+, Ni2+, Cu2+ and Zn2+ chloride gave two series of metal complexes with general formula [ML2 (OH2)2]2Cl and [ML2 (caf)2]2Cl. Their complexes were identified by FTIR, UV-visible spectra, 1H, 13C, NMR, EPR, XRD and molar conductance. The molar conductance reveals that the new series of metal complexes are non-electrolytes. The postulated octahedral structure of the obtained complexes is also proposed on spectroscopic data analysis.
Soroko, S I; Maksimova, I A; Protasova, O V
2014-01-01
By means of the nuclear-emission spectral analysis with inductively connected argon plasma were studied the contents of 28 macro- and trace elements (Al, Ag, Li, Ba, Bi, Ca, Cd, Co, Cr, Cu, Fe, Ga, In, K, Mg, Mn, Na, Ni, Mo, P, Zn, Se, Tl, Pb, Sr, S, Si) in the hair of children and teenagers living in the European North of the Russian Federation (Arkhangelsk region). There were revealed both: decrease and increase of some elements' contents. Also were revealed the dynamics of mentioned elements contents in the hair of the same children in different years. Significant individual variability of the macro and trace elements' status of children-northerners and some gender dependence were revealed.
3D multiplexed immunoplasmonics microscopy
NASA Astrophysics Data System (ADS)
Bergeron, Éric; Patskovsky, Sergiy; Rioux, David; Meunier, Michel
2016-07-01
Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence.Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence. Electronic supplementary information (ESI) available: Characterization of functionalized nanoparticles by UV-visible-NIR spectroscopy, standard dark field microscopy and reflected light microscopy. Immunofluorescence of cells. See DOI: 10.1039/c6nr01257d
NASA Astrophysics Data System (ADS)
Reddy, C. V.; Rao, L. V. Krishna; Satish, D. V.; Shim, J.; Ravikumar, R. V. S. S. N.
2015-11-01
The mild and simple solution method was used for the synthesis of Co2+- and Ni2+-doped CdO powders at room temperature. The prepared powders were characterized using powder X-ray diffraction, scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS), optical absorption, and Fourier transform infrared spectroscopy (FTIR). From the powder X-ray diffraction patterns, it has been observed that the prepared Co2+ and Ni2+ ion-doped CdO powders belong to the cubic phase, and the evaluated average crystalline sizes of the powders are 20 and 14 nm, respectively. The SEM images and the EDS spectra show that the prepared powders are distributed over different sizes in the grain boundaries. Optical absorption studies allow determination of site symmetry of the metal ion with its ligands. The crystal field (Dq) and inter-electronic repulsion (B and C) parameters have been evaluated from the optical absorption spectra. The FTIR spectra show the characteristic fundamental vibrations of the metal oxide and CdO.
Pankiewicz, C G; de Assis, P-L; Filho, P E Cabral; Chaves, C R; de Araújo, E N D; Paniago, R; Guimarães, P S S
2015-09-01
We investigate the effects of the excitation power on the photoluminescence spectra of aqueous CdTe/CdS core-shell quantum dots. We have focused our efforts on nanoparticles that are drop-cast on a silicon nitride substrate and dried out. Under such conditions, the emission intensity of these nanocrystals decreases exponentially and the emission center wavelength shifts with the time under laser excitation, displaying a behavior that depends on the excitation power. In the low-power regime a blueshift occurs, which we attribute to photo-oxidation of the quantum dot core. The blueshift can be suppressed by performing the measurements in a nitrogen atmosphere. Under high-power excitation the nanoparticles thermally expand and aggregate, and a transition to a redshift regime is then observed in the photoluminescence spectra. No spectral changes are observed for nanocrystals dispersed in the solvent. Our results show a procedure that can be used to determine the optimal conditions for the use of a given set of colloidal quantum dots as light emitters for photonic crystal optical cavities.
NASA Astrophysics Data System (ADS)
Wahhaj, Zahed; Liu, Michael C.; Biller, Beth A.; Clarke, Fraser; Nielsen, Eric L.; Close, Laird M.; Hayward, Thomas L.; Mamajek, Eric E.; Cushing, Michael; Dupuy, Trent; Tecza, Matthias; Thatte, Niranjan; Chun, Mark; Ftaclas, Christ; Hartung, Markus; Reid, I. Neill; Shkolnik, Evgenya L.; Alencar, Silvia H. P.; Artymowicz, Pawel; Boss, Alan; de Gouveia Dal Pino, Elisabethe; Gregorio-Hetem, Jane; Ida, Shigeru; Kuchner, Marc; Lin, Douglas N. C.; Toomey, Douglas W.
2011-03-01
We present the discovery of a wide (67 AU) substellar companion to the nearby (21 pc) young solar-metallicity M1 dwarf CD-35 2722, a member of the ≈100 Myr AB Doradus association. Two epochs of astrometry from the NICI Planet-Finding Campaign confirm that CD-35 2722 B is physically associated with the primary star. Near-IR spectra indicate a spectral type of L4±1 with a moderately low surface gravity, making it one of the coolest young companions found to date. The absorption lines and near-IR continuum shape of CD-35 2722 B agree especially well the dusty field L4.5 dwarf 2MASS J22244381-0158521, while the near-IR colors and absolute magnitudes match those of the 5 Myr old L4 planetary-mass companion, 1RXS J160929.1-210524 b. Overall, CD-35 2722 B appears to be an intermediate-age benchmark for L dwarfs, with a less peaked H-band continuum than the youngest objects and near-IR absorption lines comparable to field objects. We fit Ames-Dusty model atmospheres to the near-IR spectra and find T eff= 1700-1900 K and log(g)= 4.5 ± 0.5. The spectra also show that the radial velocities of components A and B agree to within ±10 km s-1, further confirming their physical association. Using the age and bolometric luminosity of CD-35 2722 B, we derive a mass of 31 ± 8 M Jup from the Lyon/Dusty evolutionary models. Altogether, young late-M to mid-L type companions appear to be overluminous for their near-IR spectral type compared with field objects, in contrast to the underluminosity of young late-L and early-T dwarfs. Based on observations obtained at the Gemini Observatory, which is operated by the Association of Universities for Research in Astronomy, Inc., under a cooperative agreement with the NSF on behalf of the Gemini partnership: the National Science Foundation (United States), the Science and Technology Facilities Council (United Kingdom), the National Research Council (Canada), CONICYT (Chile), the Australian Research Council (Australia), Ministério da Ciência e Tecnologia (Brazil) and Ministerio de Ciencia, Tecnología e Innovación Productiva (Argentina).
NASA Astrophysics Data System (ADS)
Bani-Yaseen, Abdulilah Dawoud; Mo'ala, Abeer
2014-10-01
In the present work the inclusion complexation of three sulfonamide (SA) drugs, namely sulfisoxazole (SSX), sulfamethizole (SMZ), and Sulfamethazine (STM) with β-cyclodextrin (β-CD) has been investigated using UV-Vis spectroscopy, DSC, 1H NMR spectroscopy, and molecular modeling methods. The binding constant (Kb) of SA:β-CD inclusion complexation was determined via applying the modified form of Benesi-Hildebrand equation employing the changes in absorbance at λmax. Obtained results revealed that SA drugs form 1:1 inclusion complex with β-CD with Kb of 650, 1532, 714 M-1 at 25 °C for SSX, SMZ, and STM, respectively. The UV-Vis absorption spectra displayed solvatochromic behavior of bathochromic shift with decreasing solvent polarity that in turn is good agreement with their behavior in the presence of β-CD in terms of environment polarity dependency. The inclusion complex formation between β-CD and tested SA drugs in liquid and solid states was confirmed by 1H NMR and DSC, respectively. Using semi-empirical quantum chemistry methods at PM3 theoretical level, inclusion complexes' structures as well as energetic and thermodynamic parameters of encapsulation were elucidated. Obtained results revealed that the encapsulation is favorably energetic and enthalpic in nature with the inclusion of the aniline moiety through the wide rim side of β-CD nano-cavity. Further, molecular modeling revealed that β-CD encapsulation of SA drugs reduced their (EHOMO - ELUMO) gap.
Enhanced photoluminescence of corrugated Al2O3 film assisted by colloidal CdSe quantum dots.
Bai, Zhongchen; Hao, Licai; Zhang, Zhengping; Huang, Zhaoling; Qin, Shuijie
2017-05-19
We present the enhanced photoluminescence (PL) of a corrugated Al 2 O 3 film enabled by colloidal CdSe quantum dots. The colloidal CdSe quantum dots are fabricated directly on a corrugated Al 2 O 3 substrate using an electrochemical deposition (ECD) method in a microfluidic system. The photoluminescence is excited by using a 150 nm diameter ultraviolet laser spot of a scanning near-field optical microscope. Owing to the electron transfer from the conduction band of the CdSe quantum dots to that of Al 2 O 3 , the enhanced photoluminescence effect is observed, which results from the increase in the recombination rate of electrons and holes on the Al 2 O 3 surface and the reduction in the fluorescence of the CdSe quantum dots. A periodically-fluctuating fluorescent spectrum was exhibited because of the periodical wire-like corrugated Al 2 O 3 surface serving as an optical grating. The spectral topographic map around the fluorescence peak from the Al 2 O 3 areas covered with CdSe quantum dots was unique and attributed to the uniform deposition of CdSe QDs on the corrugated Al 2 O 3 surface. We believe that the microfluidic ECD system and the surface enhanced fluorescence method described in this paper have potential applications in forming uniform optoelectronic films of colloidal quantum dots with controllable QD spacing and in boosting the fluorescent efficiency of weak PL devices.
Jyoti, Kiran; Bhatia, Richa Kaur; Martis, Elvis A F; Coutinho, Evans C; Jain, Upendra Kumar; Chandra, Ramesh; Madan, Jitender
2016-12-01
In present investigation, initially curcumin was complexed with 2-HP-β-CD (curcumin-2-HP-β-CD-complex) in 1:1 ratio and later amalgamated with chitosan microspheres (curcumin-2-HP-β-CD-CMs) for selective delivery in colon only through oral route of administration. Various analytical, spectral and in-silico docking techniques revealed that the curcumin was deeply inserted in the 2-HP-β-CD cavity with apparent stability constant of 3.35×10 -3 M. Furthermore, the mean particle size of 6.8±2.6μm and +39.2±4.1mV surface charge of curcumin-2-HP-β-CD-complex-CMs in addition to encapsulation efficiency of about 79.8±6.3% exhibited that the tailored microspheres were optimum for colon delivery of curcumin. This was also demonstrated in dissolution testing and standard cell proliferation assay in which curcumin-2-HP-β-CD-complex-CMs exhibited maximum release in simulated colonic fluid (SCF, pH ∼7.0-8.0, almond emulsion-β-glucosidase) with improved therapeutic index in HT-29 cells. Consistently, curcumin-2-HP-β-CD-complex-CMs successively enhanced the colonic bio-distribution of curcumin by ∼8.36 folds as compared to curcumin suspension in preclinical pharmacokinetic studies. In conclusion, curcumin-2-HP-β-CD-complex-CMs warrant further in vivo tumor regression study to establish its therapeutic efficacy in experimental colon cancer. Copyright © 2016 Elsevier B.V. All rights reserved.
Broadband tunable mid-IR Cr2+:CdSe lasers for medical applications
NASA Astrophysics Data System (ADS)
Tarabrin, Mikhail K.; Lasarev, Vladimir A.; Tomilov, Sergey M.; Karasik, Valery E.; Tuchin, Valery V.
2018-04-01
Currently, lasers are widely used for surgery, medical diagnostics and oncology research. Unfortunately, most of the used laser sources have a significant drawback - the lack of operating wavelength tuning possibility, which imposes significant limitations on the investigation of biological tissues spectral properties and searching for the optimal mode of their treatment. Comparison between different promising mid-IR sources was made. We report on development of mid-infrared (mid-IR) tunable lasers based on the Cr2+:CdSe single-crystals. These lasers operate in CW mode with the maximum output power of up to 2 W and possible tuning range from 2.2 to 3.6 μm.
Application of blood cadmium determination to industry using a punched disc technique.
Cernik, A A; Sayers, M P
1975-01-01
A paper disc flameless atomic absorption spectroscopy (AAS) method is described for the determination of cadmium (Cd) in blood, enabling difficulties in sample preparation to be minimized. By control of the ashing step the matrix can be removed without loss of cadmium. Problems with the fast signal response during atomization can be met by spectral band width and temperature control. At the 106 pg level (471 nmol Cd/1 blood; 5-3 mug/100 ml) the relative standard deviation (RSD) was 0-06. Results in four industrial situations are reported. This description of the method should facilitate further investigation of its application to industry using capillary or venous blood. PMID:1131342
Mang, Chao-Yong; Liu, Cai-Ping; Liu, Guang-Ming; Jiang, Bei; Lan, Hai; Wu, Ke-Chen; Yan, Ya; Li, Hai-Fei; Yang, Ming-Hui; Zhao, Yu
2015-02-05
A cyclic dipeptide often has the multiple configurations and the abundant conformations. The density functional theory (DFT) method is used to search the preferred conformation of the most probable configuration for cordycedipeptide A isolated from the culture liquid of Cordyceps sinensis. The time-dependent DFT approach is exploited to describe the profile of electronic circular dichroism (CD). The calculated results show that the most probable configuration is 3S6R7S, whose preferred conformation has a negative optical rotation and a positive lowest energy electronic CD band. Copyright © 2014 Elsevier B.V. All rights reserved.
Radiative d–d transitions at tungsten centers in II–VI semiconductors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ushakov, V. V., E-mail: ushakov@lebedev.ru; Krivobok, V. S.; Pruchkina, A. A.
2017-03-15
The luminescence spectra of W impurity centers in II–VI semiconductors, specifically, ZnSe, CdS, and CdSe, are studied. It is found that, if the electron system of 5d (W) centers is considered instead of the electron system of 3d (Cr) centers, the spectral characteristics of the impurity radiation are substantially changed. The electron transitions are identified in accordance with Tanabe–Sugano diagrams of crystal field theory. With consideration for the specific features of the spectra, it is established that, in the crystals under study, radiative transitions at 5d W centers occur between levels with different spins in the region of a weakmore » crystal field.« less
USDA-ARS?s Scientific Manuscript database
We describe here the use of label-free wide selected-ion monitoring data-independent acquisition (WiSIM-DIA) to identify proteins that are involved in the formation of tomato (Solanum lycopersicum) fruit cuticles and that are regulated by the transcription factor CUTIN DEFICIENT2 (CD2). A spectral l...
VizieR Online Data Catalog: Cyanomethyl anion and its deuterated derivatives (Liton+, 2014)
NASA Astrophysics Data System (ADS)
Liton, M.; Das., A.; Chakrabarti, S. K.
2013-11-01
We performed detailed quantum chemical simulations to present the spectral properties (infrared, electronic, and rotational) of various forms of the cyanomethyl radical. Moller-Plesset perturbation theory along with the triple-zeta, correlation-consistent basis set is used to obtain different spectroscopic constants of CH2CN-, CHDCN-, and CD2CN- in the gas phase. (4 data files).
VizieR Online Data Catalog: Cyanomethyl anion and its deuterated derivatives (Majumdar+, 2014)
NASA Astrophysics Data System (ADS)
Majumdar, L.; Das., A.; Chakrabarti, S. K.
2013-11-01
We performed detailed quantum chemical simulations to present the spectral properties (infrared, electronic, and rotational) of various forms of the cyanomethyl radical. Moller-Plesset perturbation theory along with the triple-zeta, correlation-consistent basis set is used to obtain different spectroscopic constants of CH2CN-, CHDCN-, and CD2CN- in the gas phase. (4 data files).
Blinking and spectral diffusion of CdSe/ZnS nanoparticles
NASA Astrophysics Data System (ADS)
Lorke, Axel; Braam, Daniel; Mölleken, Andreas; Offer, Matthias; Prinz, Günther; Geller, Martin
2012-02-01
Even though the tunable optical properties of colloidal nanoparticles have been studied extensively, their luminescent behaviour is still not fully understood. The random emission intermittency and the power-law of on- and off-times as well as shifts in the emission wavelength still lack a comprehensive understanding [1]. We investigate the excitonic structure of CdSe/ZnS core/shell nanoparticles using a micro-photoluminescence (PL) setup with confocal as well as imaging optics. The nanoparticles are dispersed in toluene with 1% PMMA and deposited by spin-coating on different substrates (bare Si/SiO2 as well as Si/SiO2 covered with different rough metallic layers). Depending on the substrate, we observe emission intermittency or nearly blinking-free emission with spectral jumps of 25 meV in the emission energy. Both can be assigned to excitonic transitions affected by additional charge inside or outside the nanoparticle [2]. Furthermore, we observe a phonon replica of 25 meV and smaller (<10 meV) energetic shifts of the emission lines, which are likely caused random charge variations in the environment of the nanoparticle. [4pt] [1] P. Frantsuzov et al., Nature 4, 519 (2008). [0pt] [2] A. Efros, Nature Mat. 7, 612 (2008)
Temperature dependence of the pressure broadening of spectral lines
NASA Astrophysics Data System (ADS)
Roston, G. D.; Helmi, M. S.
2012-12-01
The aim of this work is to obtain a formula relating the pressure broadening coefficient of the spectral line β with the temperature T, when the difference potential ΔV(R) between the upper and lower states of the emitting atom is represented by (Lennard - Jones) potential, The obtained formula is a power index law of β on T. This formula is applied for calculating β for different interactions of Ar, Ne, TI, Hg, Cd and Zn with the inert gases (Xe, Kr, Ar, Ne and He) at different temperatures. The results of these calculations are in good agreement with the corresponding values obtained before numerically. The obtained formula is considered very important in astrophysical problems.
Calibrated infrared ground/air radiometric spectrometer
NASA Astrophysics Data System (ADS)
Silk, J. K.; Schildkraut, Elliot Robert; Bauldree, Russell S.; Goodrich, Shawn M.
1996-06-01
The calibrated infrared ground/air radiometric spectrometer (CIGARS) is a new high performance, multi-purpose, multi- platform Fourier transform spectrometer (FPS) sensor. It covers the waveband from 0.2 to 12 micrometer, has spectral resolution as fine as 0.3 cm-1, and records over 100 spectra per second. Two CIGARS units are being used for observations of target signatures in the air or on the ground from fixed or moving platforms, including high performance jet aircraft. In this paper we describe the characteristics and capabilities of the CIGARS sensor, which uses four interchangeable detector modules (Si, InGaAs, InSb, and HgCdTe) and two optics modules, with internal calibration. The data recording electronics support observations of transient events, even without precise information on the timing of the event. We present test and calibration data on the sensitivity, spectral resolution, stability, and spectral rate of CIGARS, and examples of in- flight observations of real targets. We also discuss plans for adapting CIGARS for imaging spectroscopy observations, with simultaneous spectral and spatial data, by replacing the existing detectors with a focal plane array (FPA).
Design and development of the Sentinel-2 Multi Spectral Instrument and satellite system
NASA Astrophysics Data System (ADS)
Chorvalli, Vincent; Cazaubiel, Vincent; Bursch, Stefan; Welsch, Mario; Sontag, Heinz; Martimort, Philippe; Del Bello, Umberto; Sy, Omar; Laberinti, Paolo; Spoto, François
2010-10-01
2A and Sentinel-2B satellites currently under development will ensure systematic global acquisition of all land and coastal waters in the visible and short-wave infrared spectral domain with a 5 day revisit time at the equator. The Multi Spectral Instrument is a push-broom imager providing imagery in 13 spectral channels with spatial resolutions ranging from 10 m to 60 m and a swath width of 290 Km, larger than SPOT and Landsat. The instrument features a full field of view calibration device, a silicon carbide Three Mirror Anastigmat telescope with mirror dimensions up to 600 mm, specific filter stripe assemblies, newly developed Si-CMOS and HgCDTe detectors and a low noise wavelet compression video electronics. The 1.4 Tbits/s raw image date rate is reduced down to 490 Mbits/s at the output of the instrument to cope with the overall system transmission capability. The Sentinel-2 program has entered in the CD phase in 2009. Launch of Sentinel-2A satellite is scheduled for 2013.
Weagant, Scott; Chen, Vivian; Karanassios, Vassili
2011-11-01
A battery-operated, atmospheric pressure, self-igniting, planar geometry Ar-H(2) microplasma for elemental analysis of liquid microsamples is described. The inexpensive microplasma device (MPD) fabricated for this work was a hybrid plastic-quartz structure that was formed on chips with an area (roughly) equal to that of a small-sized postage stamp (MPD footprint, 12.5-mm width by 38-mm length). Plastic substrates were chosen due to their low cost, for rapid prototyping purposes, and for a speedy microplasma device evaluation. To enhance portability, the microplasma was operated from an 18-V rechargeable battery. To facilitate portability even further, it was demonstrated that the battery can be recharged by a portable solar panel. The battery-supplied dc voltage was converted to a high-voltage ac. The ~750-μm (diameter) and 12-mm (long) Ar-H(2) (3% H(2)) microplasma was formed by applying the high-voltage ac between two needle electrodes. Spectral interference from the electrode materials or from the plastic substrate was not observed. Operating conditions were found to be key to igniting and sustaining a microplasma that was simply "warm" to the touch (thus alleviating the need for cooling or other thermal management) and that had a stable background emission. A small-sized (900 μL internal volume) electrothermal vaporization system (40-W max power) was used for microsample introduction. Microplasma background emission in the spectral region between 200 and 850 nm obtained using a portable fiber-optic spectrometer is reported and the effect of the operating conditions is described. Analyte emission from microliter volumes of dilute single-element standard solutions of Cd, Cu, K, Li, Mg, Mn, Na, Pb, and Zn is documented. The majority of spectral lines observed for the elements tested were from neutral atoms. The relative lack of emission from ion lines simplified the spectra, thus facilitating the use of a portable spectrometer. Despite the relative spectral simplicity, some spectral interference effects were noted when running a multi-element solution. An example of how interference in the spectral domain can be resolved in the time domain using selective thermal vaporization is provided. Analytical utility and performance characteristics are reported; for example, K concentrations in diluted (~30 times) bottled water were determined to be 4.1 ± 1.0 μg/mL (4 μg/mL was the stated concentration), precision was about 25%, and the estimated detection limits were in the picogram range (or in nanograms per milliliter in relative units).
Very Low Threshold ASE and Lasing Using Auger-Suppressed Nanocrystal Quantum Dots
NASA Astrophysics Data System (ADS)
Park, Young-Shin; Bae, Wan Ki; Fidler, Andrew; Baker, Tomas; Lim, Jaehoon; Pietryga, Jeffrey; Klimov, Victor
2015-03-01
We report amplified spontaneous emission (ASE) and lasing with very low thresholds obtained using thin films made of engineered thick-shell CdSe/CdS QDs that have a CdSeS alloyed layer between the CdSe core and the CdS shell. These ``alloyed'' QDs exhibit considerable reduction of Auger decay rates, which results in high biexciton emission quantum yields (QBX of ~ 12%) and extended biexciton lifetimes (τBX of ~ 4ns). By using a fs laser (400 nm at 1 kHz repetition rate) as a pump source, we measured the threshold intensity of biexciton ASE as low as 5 μJ/cm2, which is about 5 times lower than the lowest ASE thresholds reported for thick-shell QDs without interfacial alloying. Interestingly, we also observed biexciton random lasing from the same QD film. Lasing spectrum comprises several sharp peaks (linewidth ~0.2 nm), and the heights and the spectral positions of these peaks show strong dependence on the exact position of the excitation spot on the QD film. Our study suggests that further suppression of nonradiative Auger decay rates via even finer grading of the core/shell interface could lead to a further reduction in the lasing threshold and potentially realization of lasing under continuous-wave excitation.
Meckenstock, G; Heyll, A; Schneider, E M; Hildebrandt, B; Runde, V; Aul, C; Bartram, C R; Ludwig, W D; Schneider, W
1995-02-01
Coexpression of myeloid, B-, and T-lineage associated markers was found in a patient with morphologically and cytochemically undifferentiated acute leukemia. Surface marker analysis using two-color immunofluorescence staining characterized blast cells to express CD34, CD38, CD117, and class II antigens, coexpressing TdT, CD4, CD7, CD13, CD19, and CD33. Cytoplasmic expression of myeloperoxidase, CD3, and CD22 could not be demonstrated. Monosomy for chromosome 7 was found by cytogenetic analysis. The absence of clonal rearrangements of immunoglobulin or T-cell receptor genes was shown by Southern blot analysis. Using a 3H-thymidine incorporation assay, DNA synthesis of leukemic blasts could be stimulated by IL-3, IL-6 and G-CSF in vitro. The present case did not offer specific criteria of lineage commitment. Corresponding to an equivalent counterpart in normal hematopoiesis, the involved cell population may reflect an early, most immature developmental stage within a multipotent progenitor cell compartment.
Spectral mapping tools from the earth sciences applied to spectral microscopy data.
Harris, A Thomas
2006-08-01
Spectral imaging, originating from the field of earth remote sensing, is a powerful tool that is being increasingly used in a wide variety of applications for material identification. Several workers have used techniques like linear spectral unmixing (LSU) to discriminate materials in images derived from spectral microscopy. However, many spectral analysis algorithms rely on assumptions that are often violated in microscopy applications. This study explores algorithms originally developed as improvements on early earth imaging techniques that can be easily translated for use with spectral microscopy. To best demonstrate the application of earth remote sensing spectral analysis tools to spectral microscopy data, earth imaging software was used to analyze data acquired with a Leica confocal microscope with mechanical spectral scanning. For this study, spectral training signatures (often referred to as endmembers) were selected with the ENVI (ITT Visual Information Solutions, Boulder, CO) "spectral hourglass" processing flow, a series of tools that use the spectrally over-determined nature of hyperspectral data to find the most spectrally pure (or spectrally unique) pixels within the data set. This set of endmember signatures was then used in the full range of mapping algorithms available in ENVI to determine locations, and in some cases subpixel abundances of endmembers. Mapping and abundance images showed a broad agreement between the spectral analysis algorithms, supported through visual assessment of output classification images and through statistical analysis of the distribution of pixels within each endmember class. The powerful spectral analysis algorithms available in COTS software, the result of decades of research in earth imaging, are easily translated to new sources of spectral data. Although the scale between earth imagery and spectral microscopy is radically different, the problem is the same: mapping material locations and abundances based on unique spectral signatures. (c) 2006 International Society for Analytical Cytology.
Sreenan, J J; Tbakhi, A; Edinger, M G; Tubbs, R R
1997-02-01
Isotypic control reagents are defined as irrelevant antibodies of the same immunoglobulin class as the relevant reagent antibody in a flow cytometry panel. The use of the isotypic control antibody has been advocated as a necessary quality control measure in analysis of flow cytometry. The purpose of this study was to determine the necessity of an isotypic control antibody in the analysis of CD3+ and CD3+, CD4+ lymphocyte subsets. We performed a prospective study of 46 consecutive patient samples received for lymphocyte subset analysis to determine the need for the isotypic control. For each sample, a sham buffer (autocontrol) and isotypic control reagent were stained for three-color immunofluorescence, processed, and identically analyzed with Attractors software. The Attractors software allowed independent, multiparametric, simultaneous gating; was able to identically and reproducibly process each list mode file; and yielded population data in spreadsheet form. Statistical analysis (Fisher's z test) revealed no difference between the CD3+ autocontrol and CD3+ isotypic control (correlation = 1, P < .0001) or between the CD3+, CD4+ autocontrol and the CD3+, CD4+ isotypic control (correlation = 1, P < .0001). The elimination of the isotypic control reagent resulted in a total cost savings of $3.36 per test. Additionally, the subtraction of isotypic background can artifactually depress population enumeration. The use of an isotypic control antibody is not necessary to analyze flow cytometric data that result in discrete cell populations, such as CD3+ and CD3+, CD4+ lymphocyte subsets. The elimination of this unnecessary quality control measure results in substantial cost savings.
Portable Multispectral Colorimeter for Metallic Ion Detection and Classification
Jaimes, Ruth F. V. V.; Borysow, Walter; Gomes, Osmar F.; Salcedo, Walter J.
2017-01-01
This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView®). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution. PMID:28788082
Portable Multispectral Colorimeter for Metallic Ion Detection and Classification.
Braga, Mauro S; Jaimes, Ruth F V V; Borysow, Walter; Gomes, Osmar F; Salcedo, Walter J
2017-07-28
This work deals with a portable device system applied to detect and classify different metallic ions as proposed and developed, aiming its application for hydrological monitoring systems such as rivers, lakes and groundwater. Considering the system features, a portable colorimetric system was developed by using a multispectral optoelectronic sensor. All the technology of quantification and classification of metallic ions using optoelectronic multispectral sensors was fully integrated in the embedded hardware FPGA ( Field Programmable Gate Array) technology and software based on virtual instrumentation (NI LabView ® ). The system draws on an indicative colorimeter by using the chromogen reagent of 1-(2-pyridylazo)-2-naphthol (PAN). The results obtained with the signal processing and pattern analysis using the method of the linear discriminant analysis, allows excellent results during detection and classification of Pb(II), Cd(II), Zn(II), Cu(II), Fe(III) and Ni(II) ions, with almost the same level of performance as for those obtained from the Ultravioled and visible (UV-VIS) spectrophotometers of high spectral resolution.
Engelhardt, M; Bertz, H; Wäsch, R; Finke, J
2001-04-01
Previously, a dose-dependent influence of recombinant human granulocyte colony-stimulating factor (rhG-CSF) on CD34+ mobilization was demonstrated. In this single-center prospective analysis, 52 healthy donors were investigated to determine the efficacy of intermediate-dose rhG-CSF 2x8 microg/kg donor body weight (bw) and intermediate large volume apheresis (LVA, median 12 l) to mobilize peripheral blood progenitor cells (PBPC) for allogeneic transplantation. The median number of CD34+ cells in apheresis products was 0.45% and 2.2x10(6)/kg recipient bw per single apheresis. A total of 5.4x10(6)/kg CD34+ cells were collected with two (range: one to three) LVA. In the analysis of donor subgroups, higher peripheral blood (PB) and apheresis results were obtained in male vs female donors; however, donor weight significantly differed in both groups. Heavier donors displayed higher PB and apheresis CD34+ counts; however, when CD34+ cells/kg were adjusted to a constant bw, similar harvest results were calculated in males and females, demonstrating that gender per se does not, whereas bw does affect apheresis results. Younger donors had significantly higher PB CD34+ counts, higher CD34+ numbers per single apheresis, increased CFU, more T, B, and CD61+, comparable NK, and less CD14+ cells. A correlation analysis of donor age and apheresis results displayed an age-related decline of 0.46x10(6)/kg CD34 cells per decade of donor aging. Cell subsets in apheresis products were CD14 (49%), CD3 (22%), CD4 (13%), CD8 (7%), CD61 (20%), CD19 (5%), and CD16/56+ (3%) cells, with increasing CD14+ cells and decreasing CD3, CD4, CD8, CD61, CD19, and CD16/56+ cells on subsequent days of apheresis. Compared to our previous analysis using high- (2x12 microg) and low-dose (1x10 microg) rhG-CSF for allogeneic PBPC mobilization, the intermediate-dose showed a similar CD34+ mobilization potential to 1x10 microg rhG-CSF; however, with use of LVA, two instead of three (p<0.05) aphereses were sufficient to mobilize > or =4x10(6)/kg bw CD34+ cells in most donors. Taken together, our results demonstrate that intermediate-dose rhG-CSF sufficiently mobilizes > or =4x10(6)/kg x bw CD34+ cells with use of LVA and that especially younger donors display increased CD34+ cell numbers.
Corrente, Francesco; Bellesi, Silvia; Metafuni, Elisabetta; Puggioni, Pier Luigi; Marietti, Sara; Ciminello, Angela Maria; Za, Tommaso; Sorà, Federica; Fianchi, Luana; Sica, Simona; De Stefano, Valerio; Chiusolo, Patrizia
2018-05-01
We performed a retrospective analysis of 88 adult patients with B-ALL diagnosed in our center by a flow-cytometric assessment. Immunophenotypic expression of leukemic cells was explored by simultaneous evaluation of positivity, percentage of expressing cells and median fluorescence intensity (MFI). BCR/ABL1 fusion transcripts were assessed by RT-PCR analysis and were identified in 36 patients (40.9%). CD10 and CD34 were positive in the totality of BCR/ABL1-positive cases. Patients with gene rearrangement had a greater frequency of CD66c, CD13 and CD33 positivity compared with BCR/ABL1-negative cases. Moreover, BCR/ABL1-positive cases exhibited a greater median percentage and MFI values of CD13, CD33, CD66c, CD10, CD34 and CD25 expressions, but a lower median percentage and MFI values of CD38 and CD22 expressions than patients without gene rearrangement. Multivariate logistic regression analysis showed that CD10, CD38 and CD13 expressions were independent predictors for the presence of BCR/ABL1 rearrangement. Predictive probabilities of molecular occurrence based on these markers are proposed. © 2017 International Clinical Cytometry Society. © 2017 International Clinical Cytometry Society.
High fidelity polycrystalline CdTe/CdS heterostructures via molecular dynamics
Aguirre, Rodolfo; Chavez, Jose Juan; Zhou, Xiaowang; ...
2017-06-20
Molecular dynamics simulations of polycrystalline growth of CdTe/CdS heterostructures have been performed. First, CdS was deposited on an amorphous CdS substrate, forming a polycrystalline film. Subsequently, CdTe was deposited on top of the polycrystalline CdS film. Cross-sectional images show grain formation at early stages of the CdS growth. During CdTe deposition, the CdS structure remains almost unchanged. Concurrently, CdTe grain boundary motion was detected after the first 24.4 nanoseconds of CdTe deposition. With the elapse of time, this grain boundary pins along the CdS/CdTe interface, leaving only a small region of epitaxial growth. CdTe grains are larger than CdS grainsmore » in agreement with experimental observations in the literature. Crystal phase analysis shows that zinc blende structure dominates over the wurtzite structure inside both CdS and CdTe grains. Composition analysis shows Te and S diffusion to the CdS and CdTe films, respectively. Lastly, these simulated results may stimulate new ideas for studying and improving CdTe solar cell efficiency.« less
Flow cytometric analysis of cell-surface and intracellular antigens in leukemia diagnosis.
Knapp, W; Strobl, H; Majdic, O
1994-12-15
New technology allows highly sensitive flow cytometric detection and quantitative analysis of intracellular antigens in normal and malignant hemopoietic cells. With this technology, the earliest stages of myeloid and lymphoid differentiation can easily and reliably be identified using antibodies directed against (pro-)myeloperoxidase/MPO, CD22 and CD3 antigens, respectively. Particularly for the analysis of undifferentiated acute myeloblastic leukemia (AML) cells, the immunological demonstration of intracellular MPO or its enzymatically inactive proforms is highly relevant, since other myeloid marker molecules such as CD33, CD13, or CDw65 are either not restricted to the granulomonocytic lineage or appear later in differentiation. By combining MPO staining with staining for lactoferrin (LF), undifferentiated cells can be distinguished from the granulomonocytic maturation compartment in bone marrow, since LF is selectively expressed from the myelocyte stage of differentiation onward. The list of informative intracellular antigens to be used in leukemia cell analysis will certainly expand in the near future. One candidate, intracellular CD68, has already been tested by us, and results are presented. Also dealt within this article are surface marker molecules not (as yet) widely used in leukemia cell analysis but with the potential to provide important additional information. Among them are the surface structures CD15, CD15s, CDw65, CD79a (MB-1), CD79b (B29), CD87 (uPA-R), and CD117 (c-kit).
Highlights of the new Emission Norm for the Regulation of Light Pollution in Northern Chile
NASA Astrophysics Data System (ADS)
Sanhueza, Pedro
2015-08-01
Due to the need to deal with the new menace of LEDS, which are very blue emitters, and to address other shortcomings regarding scattering and over illumination of the first lighting regulations passed in Chile in 1998 (DS 686/1998), the Chilean Ministry of Environment (MMA) approved new regulations by Presidential decree (DS 043/2012) on May 03, 2013. This new version of the regulations was developed by OPCC in collaboration with the MMA.This new environmental standard includes the following main restrictions:A full-cut-off requirement for general lighting, which means 0.49cd/Klumen at 90º (i.e., no light distribution above horizontal).For sport and recreational activities, an allowed level of 10cd/Klumen at 90º, together with a visor to cut upper-hemisphere emissions.Spectral restrictions divided into three regulated regions of the visible spectrum (as compared to the total light emission between 380 and 780nm): (a) not more than 15% of total light output in the range 300 to 380nm; (b) not more than 15% in the range 380 to 499nm; and (c) not more than 50% in the range 781nm to 1micron.Over illumination restricted to not more than 20% over the Chilean standard (NSEG 9 n71) for minimal levels in public lighting.Billboards with inner sources of illuminations (LED or plasma big screens) must emit no more than 50cd/m2 at night. No spectral restriction is applied.This new lighting regulation has not come into force yet, due to a delay in approving complementary technical protocols. Enforcement is also a critical issue to deal with, given that the institutional environmental framework in Chile is being modified.The OPCC is working with both the Ministry of Public Works and also Ministry of Housing, seeking to go beyond the new lighting regulation by applying a more restrictive approach in terms of spectral restriction, promoting the use of warm white LEDS with a CCT of 2.700 Kº and, in the case of outdoor illumination near professional observatories, monochromatic amber LEDS.
Unfolding the band structure of disordered solids: From bound states to high-mobility Kane fermions
NASA Astrophysics Data System (ADS)
Rubel, O.; Bokhanchuk, A.; Ahmed, S. J.; Assmann, E.
2014-09-01
Supercells are often used in ab initio calculations to model compound alloys, surfaces, and defects. One of the main challenges of supercell electronic structure calculations is to recover the Bloch character of electronic eigenstates perturbed by disorder. Here we apply the spectral weight approach to unfolding the electronic structure of group III-V and II-VI semiconductor solid solutions. The illustrative examples include formation of donorlike states in dilute Ga(PN) and associated enhancement of its optical activity, direct observation of the valence band anticrossing in dilute GaAs:Bi, and a topological band crossover in ternary (HgCd)Te alloy accompanied by emergence of high-mobility Kane fermions. The analysis facilitates interpretation of optical and transport characteristics of alloys that are otherwise ambiguous in traditional first-principles supercell calculations.
Synthesis, spectral studies and biological evaluation of 2-aminonicotinic acid metal complexes
NASA Astrophysics Data System (ADS)
Nawaz, Muhammad; Abbasi, Muhammad Waseem; Hisaindee, Soleiman; Zaki, Muhammad Javed; Abbas, Hira Fatima; Mengting, Hu; Ahmed, M. Arif
2016-05-01
We synthesized 2-aminonicotinic acid (2-ANA) complexes with metals such as Co(II), Fe(III), Ni(II), Mn(II), Zn(II), Ag(I),Cr(III), Cd(II) and Cu(II) in aqueous media. The complexes were characterized and elucidated using FT-IR, UV-Vis, a fluorescence spectrophotometer and thermo gravimetric analysis (TGA). TGA data showed that the stoichiometry of complexes was 1:2 metal/ligand except for Ag(I) and Mn(II) where the ratio was 1:1. The metal complexes showed varied antibacterial, fungicidal and nematicidal activities. The silver and zinc complexes showed highest activity against Bacillus subtilis and Bacillus licheniformis respectively. Fusarium oxysporum was highly susceptible to nickel and copper complexes whereas Macrophomina phaseolina was completely inert to the complexes. The silver and cadmium complexes were effective against the root-knot nematode Meloidogyne javanica.
CdTe focal plane detector for hard x-ray focusing optics
NASA Astrophysics Data System (ADS)
Seller, Paul; Wilson, Matthew D.; Veale, Matthew C.; Schneider, Andreas; Gaskin, Jessica; Wilson-Hodge, Colleen; Christe, Steven; Shih, Albert Y.; Gregory, Kyle; Inglis, Andrew; Panessa, Marco
2015-08-01
The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 mm x 20 mm CdTe-based detector with 250 μm square pixels (80x80 pixels) which achieves 1 keV FWHM @ 60 keV and gives full spectroscopy between 5 keV and 200 keV. An added advantage of these detectors is that they have a full-frame readout rate of 10 kHz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1mm-thick CdTe detectors are tiled into a 2x2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flightsuitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.
CdTe Focal Plane Detector for Hard X-Ray Focusing Optics
NASA Technical Reports Server (NTRS)
Seller, Paul; Wilson, Matthew D.; Veale, Matthew C.; Schneider, Andreas; Gaskin, Jessica; Wilson-Hodge, Colleen; Christe, Steven; Shih, Albert Y.; Inglis, Andrew; Panessa, Marco
2015-01-01
The demand for higher resolution x-ray optics (a few arcseconds or better) in the areas of astrophysics and solar science has, in turn, driven the development of complementary detectors. These detectors should have fine pixels, necessary to appropriately oversample the optics at a given focal length, and an energy response also matched to that of the optics. Rutherford Appleton Laboratory have developed a 3-side buttable, 20 millimeter x 20 millimeter CdTe-based detector with 250 micrometer square pixels (80 x 80 pixels) which achieves 1 kiloelectronvolt FWHM (Full-Width Half-Maximum) @ 60 kiloelectronvolts and gives full spectroscopy between 5 kiloelectronvolts and 200 kiloelectronvolts. An added advantage of these detectors is that they have a full-frame readout rate of 10 kilohertz. Working with NASA Goddard Space Flight Center and Marshall Space Flight Center, 4 of these 1 millimeter-thick CdTe detectors are tiled into a 2 x 2 array for use at the focal plane of a balloon-borne hard-x-ray telescope, and a similar configuration could be suitable for astrophysics and solar space-based missions. This effort encompasses the fabrication and testing of flight-suitable front-end electronics and calibration of the assembled detector arrays. We explain the operation of the pixelated ASIC readout and measurements, front-end electronics development, preliminary X-ray imaging and spectral performance, and plans for full calibration of the detector assemblies. Work done in conjunction with the NASA Centers is funded through the NASA Science Mission Directorate Astrophysics Research and Analysis Program.
NASA Astrophysics Data System (ADS)
Boopathi, K.; Babu, S. Moorthy; Jagan, R.; Ramasamy, P.
2017-12-01
The new inorganic-organic hybrid material aquadiiodo (3-aminopropanoic acid) cadmium (II) [ADI (3-AP) Cd] has been successfully synthesized and good quality crystals have been grown by slow evaporation solution technique. The structure was determined by single crystal X-ray diffraction at room temperature. The compound crystallizes in monoclinic crystal system with centro symmetric space group P21/c and four molecules in the unit cell. The structure of the title compound was further confirmed by 1H and 13C nuclear magnetic resonance spectral analysis. FT-IR spectroscopy was used to confirm the presence of various functional groups in the compound. The transmittance and optical parameters of the crystal were studied by UV- Visible-NIR spectroscopy. The thermal stability of the grown crystal was evaluated using thermogravimetric and differential thermal analyses. Mechanical hardness has been identified by Vickers micro hardness study and work hardening coefficient was calculated. Dielectric measurement was carried out as a function of frequency and results are discussed. The growth mechanism of the crystal was assessed by chemical etching studies. The third-order nonlinear optical susceptibility of [ADI (3-AP) Cd] was derived using the Z-scan technique, and it was 3.24955 × 10-8 esu. The positive nonlinear refractive index 2.48505 × 10-11 m2/W, is an indication of self-defocusing optical nonlinearity of the sample. It is believed that the [ADI (3-AP) Cd] is a promising new candidate for developing efficient nonlinear optical and optical power limiting devices.
Thermodynamic analysis of vapor-phase epitaxy of CdTe using a metallic Cd source
NASA Astrophysics Data System (ADS)
Iso, Kenji; Murakami, Hisashi; Koukitu, Akinori
2017-07-01
Thermodynamic analysis of CdTe growth using cost-effective metallic Cd and dialkyl telluride was performed. The major vapor species at source zone in equilibrium were gaseous Cd for the group-II precursor, and Te2 and H2Te for the group-VI precursors. The driving force for the CdTe deposition was still positive even at 650 °C. This indicates that CdTe formation from gaseous Cd can proceed thermodynamically. Furthermore, the calculations showed that CdTe decomposes at higher temperature and increasing the II/VI ratio increases the limit of the growth temperature, which coincides with the experimental results.
Reid, Michael J A; Baxi, Sanjiv M; Sheira, Lila A; Landay, Alan L; Frongillo, Edward A; Adedimeji, Adebola; Cohen, Mardge H; Wentz, Eryka; Gustafson, Deborah R; Merenstein, Daniel; Hunt, Peter W; Tien, Phyllis C; Weiser, Sheri D
2017-08-15
A low proportion of CD28CD8 T cells that express CD57 is associated with increased mortality in HIV infection. The effect of increasing body mass index (BMI) changes in the proportion of CD57CD28CD8 T cells among HIV-infected individuals on antiretroviral therapy is unknown. In a US cohort of HIV-infected women, we evaluated associations of BMI and waist circumference with 3 distinct CD8 T cell phenotypes: % CD28CD57CD8 T cells, % CD57 of CD28CD8 T cells, and % CD28 of all CD8 T cells. Multivariable linear regression analysis was used to estimate beta coefficients for each of 3 T-cell phenotypes. Covariates included HIV parameters (current and nadir CD4, current viral load), demographics (age, race, income, and study site), and lifestyle (tobacco and alcohol use) factors. Of 225 participants, the median age was 46 years and 50% were obese (BMI >30 m/kg). Greater BMI and waist circumference were both associated with higher % CD28CD57CD8 T cells and % CD57 of all CD28CD8 T cells in multivariable analysis, including adjustment for HIV viral load (all P < 0.05). The association between greater BMI and the overall proportion of CD28 CD8 cells in fully adjusted models (0.078, 95% confidence interval: -0.053 to 0.209) was not significant. In this analysis, greater BMI and waist circumference are associated with greater expression of CD57 on CD28CD8 T cells and a greater proportion of CD57CD28 CD8 T cells. These findings may indicate that increasing BMI is immunologically protective in HIV-infected women. Future research is needed to understand the prognostic importance of these associations on clinical outcomes.
Absorption properties of metal-semiconductor hybrid nanoparticles.
Shaviv, Ehud; Schubert, Olaf; Alves-Santos, Marcelo; Goldoni, Guido; Di Felice, Rosa; Vallée, Fabrice; Del Fatti, Natalia; Banin, Uri; Sönnichsen, Carsten
2011-06-28
The optical response of hybrid metal-semiconductor nanoparticles exhibits different behaviors due to the proximity between the disparate materials. For some hybrid systems, such as CdS-Au matchstick-shaped hybrids, the particles essentially retain the optical properties of their original components, with minor changes. Other systems, such as CdSe-Au dumbbell-shaped nanoparticles, exhibit significant change in the optical properties due to strong coupling between the two materials. Here, we study the absorption of these hybrids by comparing experimental results with simulations using the discrete dipole approximation method (DDA) employing dielectric functions of the bare components as inputs. For CdS-Au nanoparticles, the DDA simulation provides insights on the gold tip shape and its interface with the semiconductor, information that is difficult to acquire by experimental means alone. Furthermore, the qualitative agreement between DDA simulations and experimental data for CdS-Au implies that most effects influencing the absorption of this hybrid system are well described by local dielectric functions obtained separately for bare gold and CdS nanoparticles. For dumbbell shaped CdSe-Au, we find a shortcoming of the electrodynamic model, as it does not predict the "washing out" of the optical features of the semiconductor and the metal observed experimentally. The difference between experiment and theory is ascribed to strong interaction of the metal and semiconductor excitations, which spectrally overlap in the CdSe case. The present study exemplifies the employment of theoretical approaches used to describe the optical properties of semiconductors and metal nanoparticles, to achieve better understanding of the behavior of metal-semiconductor hybrid nanoparticles.
Femtosecond characterization of vibrational optical activity of chiral molecules.
Rhee, Hanju; June, Young-Gun; Lee, Jang-Soo; Lee, Kyung-Koo; Ha, Jeong-Hyon; Kim, Zee Hwan; Jeon, Seung-Joon; Cho, Minhaeng
2009-03-19
Optical activity is the result of chiral molecules interacting differently with left versus right circularly polarized light. Because of this intrinsic link to molecular structure, the determination of optical activity through circular dichroism (CD) spectroscopy has long served as a routine method for obtaining structural information about chemical and biological systems in condensed phases. A recent development is time-resolved CD spectroscopy, which can in principle map the structural changes associated with biomolecular function and thus lead to mechanistic insights into fundamental biological processes. But implementing time-resolved CD measurements is experimentally challenging because CD is a notoriously weak effect (a factor of 10(-4)-10(-6) smaller than absorption). In fact, this problem has so far prevented time-resolved vibrational CD experiments. Here we show that vibrational CD spectroscopy with femtosecond time resolution can be realized when using heterodyned spectral interferometry to detect the phase and amplitude of the infrared optical activity free-induction-decay field in time (much like in a pulsed NMR experiment). We show that we can detect extremely weak signals in the presence of large achiral background contributions, by simultaneously measuring with a femtosecond laser pulse the vibrational CD and optical rotatory dispersion spectra of dissolved chiral limonene molecules. We have so far only targeted molecules in equilibrium, but it would be straightforward to extend the method for the observation of ultrafast structural changes such as those occurring during protein folding or asymmetric chemical reactions. That is, we should now be in a position to produce 'molecular motion pictures' of fundamental molecular processes from a chiral perspective.
Optical signal monitoring in phase modulated optical fiber transmission systems
NASA Astrophysics Data System (ADS)
Zhao, Jian
Optical performance monitoring (OPM) is one of the essential functions for future high speed optical networks. Among the parameters to be monitored, chromatic dispersion (CD) is especially important since it has a significant impact on overall system performance. In this thesis effective CD monitoring approaches for phase-shift keying (PSK) based optical transmission systems are investigated. A number of monitoring schemes based on radio frequency (RF) spectrum analysis and delay-tap sampling are proposed and their performance evaluated. A method for dispersion monitoring of differential phase-shift keying (DPSK) signals based on RF power detection is studied. The RF power spectrum is found to increase with the increase of CD and decrease with polarization mode dispersion (PMD). The spectral power density dependence on CD is studied theoretically and then verified through simulations and experiments. The monitoring sensitivity for nonreturn-to-zero differential phase-shift keying (NRZ-DPSK) and return-to-zero differential phase-shift keying (RZ-DPSK) based systems can reach 80ps/nm/dB and 34ps/nm/dB respectively. The scheme enables the monitoring of differential group delay (DGD) and CD simultaneously. The monitoring sensitivity of CD and DGD can reach 56.7ps/nm/dB and 3.1ps/dB using a bandpass filter. The effects of optical signal-to-noise ratio (OSNR), DGD, fiber nonlinearity and chirp on the monitoring results are investigated. Two RF pilot tones are employed for CD monitoring of DPSK signals. Specially selected pilot tone frequencies enable good monitoring sensitivity with minimum influence on the received signals. The dynamic range exceeding 35dB and monitoring sensitivity up to 9.5ps/nm/dB are achieved. Asynchronous sampling technique is employed for CD monitoring. A signed CD monitoring method for 10Gb/s NRZ-DPSK and RZ-DPSK systems using asynchronous delay-tap sampling technique is studied. The demodulated signals suffer asymmetric waveform distortion if there is a phase error (Deltaphi) in the delay interferometer (DI) and in the presence of residual CD. Using delay-tap sampling the scatter plots can reflect this signal distortion through their asymmetric characteristics. A distance ratio (DR) is defined to represent the change of the scatter plots which is directly related to the accumulated CD. The monitoring range can be up to +/-400ps/nm and to +/-720ps/nm for 10Gb/s NRZ-DPSK and RZ-DPSK signals with 450 phase error in DI. The monitoring sensitivity reaches +/-8ps/nm and CD polarity discrimination is realized. It is found that the signal degradation is related to the increment of the absolute value of CD or phase mismatch. The effect of different polarities of phase error on CD monitoring is also analyzed. The shoulders location depends on the sign of the product DLDeltaphi. If DLDeltaphi > 0, the shoulder will appear on trailing edge else the shoulder will appear on leading edge when DLDeltaphi < 0. The analysis shows that the phase error is identical to the frequency offset of optical source so a signed frequency offset monitoring is also demonstrated. The monitoring results show that the monitoring range can reach +/-2.2GHz and the monitoring sensitivity is around 27MHz. The effect of nonlinearity, OSNR and bandwidth of the lowpass filter on the proposed monitoring method has also been studied. The signed CD monitoring for 100Gb/s carrier suppressed return-to-zero differential quadrature phase-shift keying (CSRZ-DQPSK) system based on the delay-tap sampling technology is demonstrated. The monitoring range and monitoring resolution can goes up to +/-32ps/nm and +/-8ps/nm, respectively. A signed CD and optical carrier wavelength monitoring scheme using cross-correlation method for on-off keying (00K) wavelength division multiplexing (WDM) system is proposed and demonstrated. CD monitoring sensitivity is high and can be less than 10% of the bit period. Wavelength monitoring is implemented using the proposed approach. The monitoring results show that the sensitivity can reach up to 1.37ps/GHz.
Hybrid least squares multivariate spectral analysis methods
Haaland, David M.
2002-01-01
A set of hybrid least squares multivariate spectral analysis methods in which spectral shapes of components or effects not present in the original calibration step are added in a following estimation or calibration step to improve the accuracy of the estimation of the amount of the original components in the sampled mixture. The "hybrid" method herein means a combination of an initial classical least squares analysis calibration step with subsequent analysis by an inverse multivariate analysis method. A "spectral shape" herein means normally the spectral shape of a non-calibrated chemical component in the sample mixture but can also mean the spectral shapes of other sources of spectral variation, including temperature drift, shifts between spectrometers, spectrometer drift, etc. The "shape" can be continuous, discontinuous, or even discrete points illustrative of the particular effect.
Akagi, Junji; Baba, Hideo; Sekine, Teruaki; Ogawa, Kenji
2018-01-01
Treatment with activated autologous lymphocytes (AALs) has demonstrated mixed results for cancer treatment. Preliminary results revealed that the proportion of cluster of differentiation (CD)8+CD57+ T cells is significantly increased in AALs, indicating that they are able to determine treatment outcome. Therefore, the role of CD8+CD57+ T cells in AAL efficacy was investigated. T lymphocytes were isolated from 35 patients with stage IV gastric carcinomas (17 men and 18 women; aged 41–84 years) receiving immunotherapy using AALs (IAAL). Using fluorescence activated cell sorting, CD8, CD27, CD57, and forkhead box protein 3 (FOXP3) expression was investigated on CD8+ T cell populations in CD8+ T cell differentiation prior to and following in vitro culture. The association between these populations and progression-free survival (PFS) was analyzed using Cox univariate, and multivariate analyses and Kaplan-Meier survival analysis. CD57 expression was negative in early-differentiated CD8+ T cells (CD27+CD8+CD57−), and positive in intermediate- (CD27+CD8+CD57+) and terminal- (CD27−CD8+CD57+) differentiated CD8+ T cells. Univariate analysis revealed a significant association between terminal-CD8+ T cells and longer PFS times (P=0.035), whereas CD57−FOXP3+CD8+ T cells were associated with shorter PFS times. Multivariate analysis revealed that CD57−FOXP3+CD8+ T cells was an independent poor prognostic factor, whereas CD57+FOXP3+CD8+ T cells were not associated with PFS. Although IAAL increased the proportion of terminal-CD8+ T cells relative to the pre-culture proportions, patients with a high CD57−FOXP3+CD8+ T cell percentage exhibited repressed terminal-CD8+ T cell induction, leading to poor patient prognosis. Terminally differentiated CD27−CD8+CD57+ T cells were responsible for the effectiveness of AALs; however, CD57−FOXP3+CD8+ T cells abrogated their efficacy, possibly by inhibiting their induction.
NASA Astrophysics Data System (ADS)
Sultan, J. S.; Fezea, S. M.; Mousa, F. H.
2018-05-01
A binucleating tetradentate Schiff base ligand, 1,4- di[amino methylene carboxylic] phenylene (H2L) and its forth new binuclear complexes [Co(II), Cu(II), Zn(II) and Cd(II)] were prepared via reaction metal (II) chloride with ligand (H2L) using 2:1 (M:L) in ethanol solvent. The new ligand (H2L) and its complexes were characterized by elemental microanalysis (C.H.N), atomic absorption, chloride content, molar conductance’s magnetic susceptibility, FTIR UV- Vis spectral and, 1H, 13 C- NMR (for H2L). The antibacterial activity with bacteria activity with bacteria, Staphylococcus aureus, Bacillus and Esccherichia Coli were studied.
Method for surface passivation and protection of cadmium zinc telluride crystals
Mescher, Mark J.; James, Ralph B.; Schlesinger, Tuviah E.; Hermon, Haim
2000-01-01
A method for reducing the leakage current in CZT crystals, particularly Cd.sub.1-x Zn.sub.x Te crystals (where x is greater than equal to zero and less than or equal to 0.5), and preferably Cd.sub.0.9 Zn.sub.0.1 Te crystals, thereby enhancing the ability of these crystal to spectrally resolve radiological emissions from a wide variety of radionuclides. Two processes are disclosed. The first method provides for depositing, via reactive sputtering, a silicon nitride hard-coat overlayer which provides significant reduction in surface leakage currents. The second method enhances the passivation by oxidizing the CZT surface with an oxygen plasma prior to silicon nitride deposition without breaking the vacuum state.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sukhorukov, Yu. P., E-mail: suhorukov@imp.uran.ru; Telegin, A. V.; Bebenin, N. G.
2015-09-15
The concentration, temperature, and magnetic-field dependences of the magnetoreflection and magnetotransmission of natural light in the infrared spectral range and the Kerr effect in single crystals of ferromagnetic Hg{sub 1-x}Cd{sub x}Cr{sub 2}Se{sub 4} (0 ⩽ x ⩽ 1) spinels have been studied. A relationship of the magneto-optical properties to the electronic band structure of spinels has been established. The most significant changes in the spectra of magnetoreflection, magnetotransmission, and the Kerr effect are shown to be observed for 0.1 < x < 0.25 and are attributable to a rearrangement of the band structure as the composition changes.
Band-filling of solution-synthesized CdS nanowires.
Puthussery, James; Lan, Aidong; Kosel, Thomas H; Kuno, Masaru
2008-02-01
The band edge optical characterization of solution-synthesized CdS nanowires (NWs) is described. Investigated wires are made through a solution-liquid-solid approach that entails the use of low-melting bimetallic catalyst particles to seed NW growth. Resulting diameters are approximately 14 nm, and lengths exceed 1 microm. Ensemble diameter distributions are approximately 13%, with corresponding intrawire diameter variations of approximately 5%. High-resolution transmission electron micrographs show that the wires are highly crystalline and have the wurtzite structure with growth along at least two directions: [0001] and [1010]. Band edge emission is observed with estimated quantum yields between approximately 0.05% and 1%. Complementary photoluminescence excitation spectra show structure consistent with the linear absorption. Carrier cooling dynamics are subsequently examined through ensemble lifetime and transient differential absorption measurements. The former reveals unexpectedly long band edge decays that extend beyond tens of nanoseconds. The latter indicates rapid intraband carrier cooling on time scales of 300-400 fs. Subsequent recovery at the band edge contains significant Auger contributions at high intensities which are usurped by other, possibly surface-related, carrier relaxation pathways at lower intensities. Furthermore, an unusual intensity-dependent transient broadening is seen, connected with these long decays. The effect likely stems from band-filling on the basis of an analysis of observed spectral shifts and line widths.
NASA Astrophysics Data System (ADS)
Khajeh, Masoumeh Ashrafi; Dehghan, Gholamreza; Dastmalchi, Siavoush; Shaghaghi, Masoomeh; Iranshahi, Mehrdad
2018-03-01
DNA is a major target for a number of anticancer substances. Interaction studies between small molecules and DNA are essential for rational drug designing to influence main biological processes and also introducing new probes for the assay of DNA. Tschimgine (TMG) is a monoterpene derivative with anticancer properties. In the present study we tried to elucidate the interaction of TMG with calf thymus DNA (CT-DNA) using different spectroscopic methods. UV-visible absorption spectrophotometry, fluorescence and circular dichroism (CD) spectroscopies as well as molecular docking study revealed formation of complex between TMG and CT-DNA. Binding constant (Kb) between TMG and DNA was 2.27 × 104 M- 1, that is comparable to groove binding agents. The fluorescence spectroscopic data revealed that the quenching mechanism of fluorescence of TMG by CT-DNA is static quenching. Thermodynamic parameters (ΔH < 0 and ΔS < 0) at different temperatures indicated that van der Waals forces and hydrogen bonds were involved in the binding process of TMG with CT-DNA. Competitive binding assay with methylene blue (MB) and Hoechst 33258 using fluorescence spectroscopy displayed that TMG possibly binds to the minor groove of CT-DNA. These observations were further confirmed by CD spectral analysis, viscosity measurements and molecular docking.
First principles study on the elastic and electronic properties of CdX (X = S, Se and Te)
NASA Astrophysics Data System (ADS)
Sharma, Sheetal; Verma, Ajay Singh; Sarkar, Bimal Kumar; Bhandari, Rajiv; Jindal, Vijay Kumar
2011-12-01
Wide band gap semiconductors are emerging as a potential candidate for optically active materials in blue green spectral region and operating at high power level and high temperature. CdX, X = S, Se and Te are wide band gap semiconductors having applications in optoelectronics devices. In this paper we investigated the elastic and electronic properties of Cadmium chalcogenide (cubic zinc-blende (ZB) structure) using standard Kohn-Sham self consistent density functional theory method (DFT) that uses non conserving pseudopotentials in fully nonlocal form within the generalized gradient approximation (GGA) for the exchange-correlation potential. The independent elastic constants, C11, C12 and C44, are calculated from direct computation of stresses generated by small strains. The shear modulus and Young's modulus are estimated for CdX. Using the GGA for the exchange correlation potential, the calculated direct fundamental band gap value is in very good agreement with the measured one.
Combinatorial chemical bath deposition of CdS contacts for chalcogenide photovoltaics
Mokurala, Krishnaiah; Baranowski, Lauryn L.; de Souza Lucas, Francisco W.; ...
2016-08-01
Contact layers play an important role in thin film solar cells, but new material development and optimization of its thickness is usually a long and tedious process. A high-throughput experimental approach has been used to accelerate the rate of research in photovoltaic (PV) light absorbers and transparent conductive electrodes, however the combinatorial research on contact layers is less common. Here, we report on the chemical bath deposition (CBD) of CdS thin films by combinatorial dip coating technique and apply these contact layers to Cu(In,Ga)Se 2 (CIGSe) and Cu 2ZnSnSe 4 (CZTSe) light absorbers in PV devices. Combinatorial thickness steps ofmore » CdS thin films were achieved by removal of the substrate from the chemical bath, at regular intervals of time, and in equal distance increments. The trends in the photoconversion efficiency and in the spectral response of the PV devices as a function of thickness of CdS contacts were explained with the help of optical and morphological characterization of the CdS thin films. The maximum PV efficiency achieved for the combinatorial dip-coating CBD was similar to that for the PV devices processed using conventional CBD. Finally, the results of this study lead to the conclusion that combinatorial dip-coating can be used to accelerate the optimization of PV device performance of CdS and other candidate contact layers for a wide range of emerging absorbers.« less
Thomsen, Hanna; Benkovics, Gábor; Fenyvesi, Éva; Farewell, Anne; Malanga, Milo; Ericson, Marica B
2017-10-15
Cyclodextrin (CD) polymers are interesting nanoparticulate systems for pharmaceutical delivery; however, knowledge regarding their applications towards delivery into complex microbial biofilm structures is so far limited. The challenge is to demonstrate penetration and transport through the biofilm and its exopolysaccharide matrix. The ideal functionalization for penetration into mature biofilms is unexplored. In this paper, we present a novel set of rhodamine labelled βCD-polymers, with different charge moieties, i.e., neutral, anionic, and cationic, and explore their potential delivery into mature Staphylococcus epidermidis biofilms using multiphoton laser scanning microscopy (MPM). The S. epidermidis biofilms, being a medically relevant model organism, were stained with SYTO9. By using MPM, three-dimensional imaging and spectral investigation of the distribution of the βCD-polymers could be obtained. It was found that the cationic βCD-polymers showed significantly higher integration into the biofilms, compared to neutral and anionic functionalized βCDs. None of the carriers presented any inherent toxicity to the biofilms, meaning that the addition of rhodamine moiety does not affect the inertness of the delivery system. Taken together, this study demonstrates a novel approach by which delivery of fluorescently labelled CD nanoparticles to bacterial biofilms can be explored using MPM. Future studies should be undertaken investigating the potential in using cationic functionalization of CD based delivery systems for targeting anti-microbial effects in biofilms. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Velicu, S.; Bommena, R.; Morley, M.; Zhao, J.; Fahey, S.; Cowan, V.; Morath, C.
2013-09-01
The development of a broadband IR focal plane array poses several challenges in the area of detector design, material, device physics, fabrication process, hybridization, integration and testing. The purpose of our research is to address these challenges and demonstrate a high-performance IR system that incorporates a HgCdTe-based detector array with high uniformity and operability. Our detector architecture, grown using molecular beam epitaxy (MBE), is vertically integrated, leading to a stacked detector structure with the capability to simultaneously detect in two spectral bands. MBE is the method of choice for multiplelayer HgCdTe growth because it produces material of excellent quality and allows composition and doping control at the atomic level. Such quality and control is necessary for the fabrication of multicolor detectors since they require advanced bandgap engineering techniques. The proposed technology, based on the bandgap-tunable HgCdTe alloy, has the potential to extend the broadband detector operation towards room temperature. We present here our modeling, MBE growth and device characterization results, demonstrating Auger suppression in the LWIR band and diffusion limited behavior in the MWIR band.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Diroll, Benjamin T.; Talapin, Dmitri V.; Schaller, Richard D.
Amplified spontaneous emission (ASE) and lasing from solution-processed materials are demonstrated in the challenging violet-to-blue (430–490 nm) spectral region for colloidal nanoplatelets of CdS and newly synthesized core/shell CdS/ZnS nanoplatelets. Despite modest band-edge photoluminescence quantum yields of 2% or less for single excitons, which we show results from hole trapping, the samples exhibit low ASE thresholds. Furthermore, four-monolayer CdS samples show ASE at shorter wavelengths than any reported film of colloidal quantum-confined material. This work underlines that low quantum yields for single excitons do not necessarily lead to a poor gain medium. The low ASE thresholds originate from negligible dispersionmore » in thickness, large absorption cross sections of 2.8 × 10–14 cm–2, and rather slow (150 to 300 ps) biexciton recombination. We show that under higher-fluence excitation, ASE can kinetically outcompete hole trapping. Using nanoplatelets as the gain medium, lasing is observed in a linear optical cavity. This work confirms the fundamental advantages of colloidal quantum well structures as gain media, even in the absence of high photoluminescence efficiency.« less
Zeng, Qunying; Li, Fushan; Guo, Tailiang; Shan, Guogang; Su, Zhongmin
2016-01-01
Solution-processable light-emitting electrochemical cells (LECs) with simple device architecture have become an attractive candidate for application in next generation lighting and flat-panel displays. Herein, single layer LECs employing two cationic Ir(III) complexes showing highly efficient blue-green and yellow electroluminescence with peak current efficiency of 31.6 cd A−1 and 40.6 cd A−1, respectively, have been reported. By using both complexes in the device, color-tunable LECs with a single spectral peak in the wavelength range from 499 to 570 nm were obtained by varying their rations. In addition, the fabrication of efficient LECs was demonstrated based on low cost doctor-blade coating technique, which was compatible with the roll to roll fabrication process for the large size production. In this work, for the first time, 4 inch LEC devices by doctor-blade coating were fabricated, which exhibit the efficiencies of 23.4 cd A−1 and 25.4 cd A−1 for the blue-green and yellow emission, respectively. The exciting results indicated that highly efficient LECs with controllable color could be realized and find practical application in large size lighting and displays. PMID:27278527
Bui, Minh-Phuong N; Seo, Seong S
2014-01-01
We have developed an optical chemical sensor for the detection of organophosphate (OP) compounds using a polymerized crystalline colloidal array (PCCA) thin film composed of a close-packed colloidal array of polystyrene particles. The PCCA thin film was modified with β-cyclodextrin (β-CD) polymer as a capping cavity for the selective detection of paraoxon-ethyl and parathion-ethyl chemical agents. The fabrication of the modified PCCA thin film was optimized and the structure was characterized using scanning electron microscopy (SEM). The arrangement of polystyrene particles in the PCCA follows a pattern of the fcc (111) planes with strong diffraction peak in the visible spectral region and pH dependence. The diffraction peak of the β-CD modified PCCA thin film showed a red shift according to the change of paraoxon-ethyl and parathion-ethyl concentrations at a fast response time (10 s) and high sensitivity with detection limits of 2.0 and 3.4 ppb, respectively. Furthermore, the proposed interaction mechanism of β-CD with paraoxon-ethyl and parathion-ethyl in the β-CD modified PCCA thin film were discussed.
Properties of a CdZnO/ZnO multiple quantum-well light-emitting diode
NASA Astrophysics Data System (ADS)
Liu, Zhan-Hui; Zhang, Li-Li; Li, Qing-Fang; Zhang, Rong; Xie, Zi-Li; Xiu, Xiang-Qian; Liu, Bin
2016-10-01
A CdZnO/ZnO multiple quantum-well light-emitting diode (LED) structure was successfully grown by using plasma-assisted molecular beam epitaxy on a p-GaN template that had been grown by using metal-organic chemical-vapor deposition on a c-sapphire substrate. The properties of the sample were characterized by using high-resolution X-ray diffraction, transmission electron microscopy, and temperature-dependent photoluminescence measurements. The light output performance of the CdZnO/ZnO QW LED device was also investigated in detail by using I-V and electroluminescence spectral measurements. The characterization showed that our CdZnO/ZnO QW LED structure had good crystalline quality and weaker carrier localization. Owing to the heterojunction structure, the I-V curve indicated that the LED device had a higher turn-on voltage and series resistance. The EL measurement demonstrated that for our LED device's optoelectronic characteristic, the carrier-screening effect played the dominant role in the emission-energy blue-shift mechanism, and the broadening of the emission energy width was mainly ascribed to the band-filling effect. Without a special heat sinking, the L-I curve exhibited slight efficiency droop after 30 mA.
A comparison of physiological indicators of sublethal cadmium stress in wetland plants
Mendelssohn, I.A.; McKee, K.L.; Kong, T.
2001-01-01
Physiological indices, including photosynthesis, chlorophyll fluorescence, adenylate energy charge (AEC) ratio, and leaf reflectance, were determined for Typha domingensis and Spartina alterniflora in response to increasing concentrations of Cd and compared with the growth responses of these species. Leaf expansion, the live/total ratio of plant aboveground biomass, and the aboveground regrowth rate after the initial harvests were significantly reduced with increasing Cd concentration in the growth medium. Of the four physiological responses measured, only photosynthesis and AEC responded to the Cd treatment before damage was visually apparent. Also, these indices were significantly correlated with leaf expansion rate and live/total ratio in most instances. Except at the end of the experiment, when the most stressed plants began to die, the Fv/Fm ratio was not significantly affected by the Cd treatment. The leaf spectral reflectance parameters showed no significant change during the entire treatment period. The significant correlation between the stress indicators and plant growth supported the findings that photosynthesis and AEC were the most responsive of the indicators tested, however, further research investigating other chlorophyll fluorescence and leaf reflectance parameters may demonstrate as well the value of these indicators in quantifying sublethal stress. ?? 2001 Elsevier Science B.V. All rights reserved.
Optoelectronics of inverted type-I CdS/CdSe core/crown quantum ring
NASA Astrophysics Data System (ADS)
Bose, Sumanta; Fan, Weijun; Zhang, Dao Hua
2017-10-01
Inverted type-I heterostructure core/crown quantum rings (QRs) are quantum-efficient luminophores, whose spectral characteristics are highly tunable. Here, we study the optoelectronic properties of type-I core/crown CdS/CdSe QRs in the zincblende phase—over contrasting lateral size and crown width. For this, we inspect their strain profiles, transition energies, transition matrix elements, spatial charge densities, electronic bandstructures, band-mixing probabilities, optical gain spectra, maximum optical gains, and differential optical gains. Our framework uses an effective-mass envelope function theory based on the 8-band k ṡ p method employing the valence force field model for calculating the atomic strain distributions. The gain calculations are based on the density-matrix equation and take into consideration the excitonic effects with intraband scattering. Variations in the QR lateral size and relative widths of core and crown (ergo the composition) affect their energy levels, band-mixing probabilities, optical transition matrix elements, emission wavelengths/intensities, etc. The optical gain of QRs is also strongly dimension and composition dependent with further dependency on the injection carrier density causing the band-filling effect. They also affect the maximum and differential gain at varying dimensions and compositions.
Hadar, Ido; Philbin, John P; Panfil, Yossef E; Neyshtadt, Shany; Lieberman, Itai; Eshet, Hagai; Lazar, Sorin; Rabani, Eran; Banin, Uri
2017-04-12
Seeded semiconductor nanorods represent a unique family of quantum confined materials that manifest characteristics of mixed dimensionality. They show polarized emission with high quantum yield and fluorescence switching under an electric field, features that are desirable for use in display technologies and other optical applications. So far, their robust synthesis has been limited mainly to CdSe/CdS heterostructures, thereby constraining the spectral tunability to the red region of the visible spectrum. Herein we present a novel synthesis of CdSe/Cd 1-x Zn x S seeded nanorods with a radially graded composition that show bright and highly polarized green emission with minimal intermittency, as confirmed by ensemble and single nanorods optical measurements. Atomistic pseudopotential simulations elucidate the importance of the Zn atoms within the nanorod structure, in particular the effect of the graded composition. Thus, the controlled addition of Zn influences and improves the nanorods' optoelectronic performance by providing an additional handle to manipulate the degree confinement beyond the common size control approach. These nanorods may be utilized in applications that require the generation of a full, rich spectrum such as energy-efficient displays and lighting.
Two-photon decay of K-shell vacancies in silver atoms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mokler, P.H.; University of Giessen, Giessen; Schaeffer, H.W.
2004-09-01
The spectral distributions for the two-photon decay modes of singly K-shell ionized silver atoms are determined by x-ray-x-ray coincidence measurements. Ag K-shell vacancies were induced by nuclear electron capture decay of radioactive cadmium isotopes {sup 109}Cd and two-photon coincidences were taken back to back (180 deg.) and at a 90 deg. opening angle for the emission. Each of the two-photon transitions from the 2s, 3s, and 3d states exhibits unique angular and spectral distributions. The measurements agree nicely with relativistic self-consistent field calculations of Tong et al. Our results also confirm and extend the earlier experimental data of Ilakovac andmore » co-workers with improved accuracy.« less
BOREAS TE-18 GeoSail Canopy Reflectance Model
NASA Technical Reports Server (NTRS)
Hall, Forrest G. (Editor); Huemmrich, K. Fred
2000-01-01
The SAIL (Scattering from Arbitrarily Inclined Leaves) model was combined with the Jasinski geo metric model to simulate canopy spectral reflectance and absorption of photosynthetically active radiation for discontinuous canopies. This model is called the GeoSail model. Tree shapes are described by cylinders or cones distributed over a plane. Spectral reflectance and transmittance of trees are calculated from the SAIL model to determine the reflectance of the three components used in the geometric model: illuminated canopy, illuminated background, shadowed canopy, and shadowed background. The model code is Fortran. sample input and output data are provided in ASCII text files. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Activity Archive Center (DAAC).
Structure of fluorescent metal clusters on a DNA template.
NASA Astrophysics Data System (ADS)
Vdovichev, A. A.; Sych, T. S.; Reveguk, Z. V.; Smirnova, A. A.; Maksimov, D. A.; Ramazanov, R. R.; Kononov, A. I.
2016-08-01
Luminescent metal clusters are a subject of growing interest in recent years due to their bright emission from visible to near infrared range. Detailed structure of the fluorescent complexes of Ag and other metal clusters with ligands still remains a challenging task. In this joint experimental and theoretical study we synthesized Ag-DNA complexes on a DNA oligonucleotide emitting in violet- green spectral range. The structure of DNA template was determined by means of various spectral measurements (CD, MS, XPS). Comparison of the experimental fluorescent excitation spectra and calculated absorption spectra for different QM/MM optimized structures allowed us to determine the detailed structure of the green cluster containing three silver atoms in the stem of the DNA hairpin structure stabilized by cytosine-Ag+-cytosine bonds.
Czarnecka, Anna M.; Lewicki, Sławomir; Helbrecht, Igor; Brodaczewska, Klaudia; Koch, Irena; Zdanowski, Robert; Król, Magdalena; Szczylik, Cezary
2016-01-01
Background Recent advancement in cancer research has shown that tumors are highly heterogeneous, and multiple phenotypically different cell populations are found in a single tumor. Cancer development and tumor growth are driven by specific types of cells—stem cell-like cancer cells (SCLCCs)—which are also responsible for metastatic spread and drug resistance. This research was designed to verify the presence of SCLCCs in renal cell cancer cell lines. Subsequently, we aimed to characterize phenotype and cell biology of CD105+ cells, defined previously as renal cell carcinoma tumor-initiating cells. The main goal of the project was to describe the gene-expression profile of stem cell-like cancer cells of primary tumor and metastatic origin. Materials and Methods Real-time PCR analysis of stemness genes (Oct-4, Nanog and Ncam) and soft agar colony formation assay were conducted to check the stemness properties of renal cell carcinoma (RCC) cell lines. FACS analysis of CD105+ and CD133+ cells was performed on RCC cells. Isolated CD105+ cells were verified for expression of mesenchymal markers—CD24, CD146, CD90, CD73, CD44, CD11b, CD19, CD34, CD45, HLA-DR and alkaline phosphatase. Hanging drop assay was used to investigate CD105+ cell-cell cohesion. Analysis of free-floating 3D spheres formed by isolated CD105+ was verified, as spheres have been hypothesized to contain undifferentiated multipotent progenitor cells. Finally, CD105+ cells were sorted from primary (Caki-2) and metastatic (ACHN) renal cell cancer cell lines. Gene-expression profiling of sorted CD105+ cells was performed with Agilent’s human GE 4x44K v2 microarrays. Differentially expressed genes were further categorized into canonical pathways. Network analysis and downstream analysis were performed with Ingenuity Pathway Analysis. Results Metastatic RCC cell lines (ACHN and Caki-1) demonstrated higher colony-forming ability in comparison to primary RCC cell lines. Metastatic RCC cell lines harbor numerous CD105+ cell subpopulations and have higher expression of stemness genes (Oct-4 and Nanog). CD105+ cells adopt 3D grape-like floating structures under handing drop conditions. Sorted CD105+ cells are positive for human mesenchymal stem cell (MSC) markers CD90, CD73, CD44, CD146, and alkaline phosphatase activity, but not for CD24 and hematopoietic lineage markers CD34, CD11b, CD19, CD45, and HLA-DR. 1411 genes are commonly differentially expressed in CD105+ cells (both from primary [Caki-2] and metastatic RCC [ACHN] cells) in comparison to a healthy kidney epithelial cell line (ASE-5063). TGF-β, Wnt/β-catenine, epithelial-mesenchymal transition (EMT), Rap1 signaling, PI3K-Akt signaling, and Hippo signaling pathway are deregulated in CD105+ cells. TGFB1, ERBB2, and TNF are the most significant transcriptional regulators activated in these cells. Conclusions All together, RCC-CD105+ cells present stemlike properties. These stem cell-like cancer cells may represent a novel target for therapy. A unique gene-expression profile of CD105+ cells could be used as initial data for subsequent functional studies and drug design. PMID:27812180
Kunnath-Velayudhan, Shajo; Goldberg, Michael F; Saini, Neeraj K; Johndrow, Christopher T; Ng, Tony W; Johnson, Alison J; Xu, Jiayong; Chan, John; Jacobs, William R; Porcelli, Steven A
2017-10-01
Analysis of Ag-specific CD4 + T cells in mycobacterial infections at the transcriptome level is informative but technically challenging. Although several methods exist for identifying Ag-specific T cells, including intracellular cytokine staining, cell surface cytokine-capture assays, and staining with peptide:MHC class II multimers, all of these have significant technical constraints that limit their usefulness. Measurement of activation-induced expression of CD154 has been reported to detect live Ag-specific CD4 + T cells, but this approach remains underexplored and, to our knowledge, has not previously been applied in mycobacteria-infected animals. In this article, we show that CD154 expression identifies adoptively transferred or endogenous Ag-specific CD4 + T cells induced by Mycobacterium bovis bacillus Calmette-Guérin vaccination. We confirmed that Ag-specific cytokine production was positively correlated with CD154 expression by CD4 + T cells from bacillus Calmette-Guérin-vaccinated mice and show that high-quality microarrays can be performed from RNA isolated from CD154 + cells purified by cell sorting. Analysis of microarray data demonstrated that the transcriptome of CD4 + CD154 + cells was distinct from that of CD154 - cells and showed major enrichment of transcripts encoding multiple cytokines and pathways of cellular activation. One notable finding was the identification of a previously unrecognized subset of mycobacteria-specific CD4 + T cells that is characterized by the production of IL-3. Our results support the use of CD154 expression as a practical and reliable method to isolate live Ag-specific CD4 + T cells for transcriptomic analysis and potentially for a range of other studies in infected or previously immunized hosts. Copyright © 2017 by The American Association of Immunologists, Inc.
T-cell immunity and cytokine production in cosmonauts after long-duration space flights
NASA Astrophysics Data System (ADS)
Morukov, B.; Rykova, M.; Antropova, E.; Berendeeva, T.; Ponomaryov, S.; Larina, I.
2011-04-01
Long-duration spaceflight effects on T-cell immunity and cytokine production were studied in 12 Russian cosmonauts flown onto the International Space Station. Specific assays were performed before launch and after landing and included analysis of peripheral leukocyte distribution, analysis of T-cell phenotype, expression of activation markers, apoptosis, proliferation of T cells in response to a mitogen, concentrations of cytokines in supernatants of cell cultures. Statistically significant increase was observed in leukocytes', lymphocytes', monocytes' and granulocytes' total number, increase in percentage and absolutely number of CD3 +CD4 +-cells, CD4 +CD45RA +-cells and CD4 +CD45RA +/CD4 +CD45RО + ratio, CD4 +CD25 +Bright regulatory cells ( p<0,05) in peripheral blood after landing. T-lymphocytes' capacity to present CD69 and CD25 on its own surfaces was increased for the majority of crewmembers. Analysis of T-cell response to PHA-stimulation in vitro revealed there were some trends toward reduced proliferation of stimulated T-lymphocytes. There was an apparent post flight decrease in secreted IFN-g for the majority of crewmembers and in most instances there was elevation in secreted IL-10. It revealed depression of IFN-g/IL-10 ratio after flight. Correlation analysis according to Spearman's rank correlation test established significant positive correlations ( p<0.05) between cytokine production and T-cell activation (CD25+, CD38+) and negative correlation ( p<0.05) between cytokine production and number of bulk memory CD4+T-cells (CD45RO+). Thus, these results suggest that T-cell dysfunction can be conditioned by cytokine dysbalance and could lead to development of disease after long-duration space flights.
Wong, Jing Lin; Hak, Chen Hong; Tai, Jun Yan; Leong, Kah Hon; Saravanan, Pichiah
2018-01-01
Carbon dots (CDs) and graphitic carbon nitride (g-C3N4) composites (CD/g-C3N4) were successfully synthesized by a hydrothermal method using urea and sugarcane juice as starting materials. The chemical composition, morphological structure and optical properties of the composites and CDs were characterized using various spectroscopic techniques as well as transmission electron microscopy. X-ray photoelectron spectroscopy (XPS) results revealed new signals for carbonyl and carboxyl groups originating from the CDs in CD/g-C3N4 composites while X-ray diffraction (XRD) results showed distortion of the host matrix after incorporating CDs into g-C3N4. Both analyses signified the interaction between g-C3N4 and CDs. The photoluminescence (PL) analysis indicated that the presence of too many CDs will create trap states at the CD/g-C3N4 interface, decelerating the electron (e−) transport. However, the CD/g-C3N4(0.5) composite with the highest coverage of CDs still achieved the best bisphenol A (BPA) degradation rate at 3.87 times higher than that of g-C3N4. Hence, the charge separation efficiency should not be one of the main factors responsible for the enhancement of the photocatalytic activity of CD/g-C3N4. Instead, the light absorption capability was the dominant factor since the photoreactivity correlated well with the ultraviolet–visible diffuse reflectance spectra (UV–vis DRS) results. Although the CDs did not display upconversion photoluminescence (UCPL) properties, the π-conjugated CDs served as a photosensitizer (like organic dyes) to sensitize g-C3N4 and injected electrons to the conduction band (CB) of g-C3N4, resulting in the extended absorption spectrum from the visible to the near-infrared (NIR) region. This extended spectral absorption allows for the generation of more electrons for the enhancement of BPA degradation. It was determined that the reactive radical species responsible for the photocatalytic activity were the superoxide anion radical (O2 •−) and holes (h+) after performing multiple scavenging tests. PMID:29515949
High throughput operando studies using Fourier transform infrared imaging and Raman spectroscopy.
Li, Guosheng; Hu, Dehong; Xia, Guanguang; White, J M; Zhang, Conrad
2008-07-01
A prototype high throughput operando (HTO) reactor designed and built for catalyst screening and characterization combines Fourier transform infrared (FT-IR) imaging and Raman spectroscopy in operando conditions. Using a focal plane array detector (HgCdTe focal plane array, 128x128 pixels, and 1610 Hz frame rate) for the FT-IR imaging system, the catalyst activity and selectivity of all parallel reaction channels can be simultaneously followed. Each image data set possesses 16 384 IR spectra with a spectral range of 800-4000 cm(-1) and with an 8 cm(-1) resolution. Depending on the signal-to-noise ratio, 2-20 s are needed to generate a full image of all reaction channels for a data set. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six novel Raman probes, one for each reaction channel, were specially designed and house built at Pacific Northwest National Laboratory, to simultaneously collect Raman spectra of the catalysts and possible reaction intermediates on the catalyst surface under operando conditions. As a model system, methanol partial oxidation reaction on silica-supported molybdenum oxide (MoO3SiO2) catalysts has been studied under different reaction conditions to demonstrate the performance of the HTO reactor.
Tunable Fabry-Perot etalon-based long-wavelength infrared imaging spectroradiometer.
Marinelli, W J; Gittins, C M; Gelb, A H; Green, B D
1999-04-20
Imaging spectrometry enables passive, stand-off detection and analysis of the chemical composition of gas plumes and surfaces over wide geographic areas. We describe the use of a long-wavelength infrared imaging spectroradiometer, comprised of a low-order tunable Fabry-Perot etalon coupled to a HgCdTe detector array, to perform multispectral detection of chemical vapor plumes. The tunable Fabry-Perot etalon used in this research provides coverage of the 9.5-14-microm spectral region with a resolution of 7-9 cm(-1). The etalon-based imaging system provides the opportunity to image a scene at only those wavelengths needed for chemical species identification and quantification and thereby minimize the data volume necessary for selective species detection. We present initial results using a brassboard imaging system for stand-off detection and quantification of chemical vapor plumes against near-ambient-temperature backgrounds. These data show detection limits of 22 parts per million by volume times meter (ppmv x m) and 0.6 ppmv x m for dimethyl methyphosphonate and SF6, respectively, for a gas/background DeltaT of 6 K. The system noise-equivalent spectral radiance is approximately 2 microW cm(-2) sr(-1) microm(-1). Model calculations are presented comparing the measured sensitivity of the sensor to the anticipated signal levels for two chemical release scenarios.
True, Lawrence D; Zhang, Hui; Ye, Mingliang; Huang, Chung-Ying; Nelson, Peter S; von Haller, Priska D; Tjoelker, Larry W; Kim, Jong-Seo; Qian, Wei-Jun; Smith, Richard D; Ellis, William J; Liebeskind, Emily S; Liu, Alvin Y
2010-01-01
A by-product in the processing of prostate tissue for cell sorting by collagenase digestion is the media supernatant that remains after the cells are harvested. These supernatants contain proteins made by the cells within the tissue. Quantitative proteomic analysis of N-glycosylated proteins detected an increased amount of CD90/THY1 in cancer supernatants compared to non-cancer supernatants. Immunohistochemistry showed that in all carcinomas, regardless of Gleason grade, a layer of CD90-positive stromal fibroblastic cells, approximately 5-to-10 cells deep, was localized to tumor glands. In contrast, a no more than 1-cell wide girth of CD90-positive stromal cells was found around benign glands. The increased number of CD90-positive stromal cells in cancer correlated with overexpression of CD90 mRNA detected by gene expression analysis of stromal cells obtained by laser-capture microdissection. There is increasing evidence that cancer-associated stroma plays a role in both tumor progression and carcinogenesis. Most experiments to identify cancer biomarkers have focused on the cancer cells. CD90, being a marker for prostate cancer-associated stroma, might be a potential biomarker for this cancer. A non-invasive test could be provided by a urine test. Proteomic analysis of urine from patients with prostate cancer identified CD90; conversely, CD90 was not detected in the urine of post-prostatectomy patients. Furthermore, this urinary CD90 protein was a variant CD90 protein not known to be expressed by such cells as lymphocytes that express CD90. These CD90 results were obtained from ∼90 cases consisting of proteomic analysis of tissue and urine, immunohistochemistry, Western blot analysis of tissue media, flow cytometry of cells from digested tissue, and reverse transcriptase polymerase chain reaction analysis of isolated stromal cells. PMID:20562849
Imaging IR spectrometer, phase 2
NASA Technical Reports Server (NTRS)
Gradie, Jonathan; Lewis, Ralph; Lundeen, Thomas; Wang, Shu-I
1990-01-01
The development is examined of a prototype multi-channel infrared imaging spectrometer. The design, construction and preliminary performance is described. This instrument is intended for use with JPL Table Mountain telescope as well as the 88 inch UH telescope on Mauna Kea. The instrument is capable of sampling simultaneously the spectral region of 0.9 to 2.6 um at an average spectral resolution of 1 percent using a cooled (77 K) optical bench, a concave holographic grating and a special order sorting filter to allow the acquisition of the full spectral range on a 128 x 128 HgCdTe infrared detector array. The field of view of the spectrometer is 0.5 arcsec/pixel in mapping mode and designed to be 5 arcsec/pixel in spot mode. The innovative optical design has resulted in a small, transportable spectrometer, capable of remote operation. Commercial applications of this spectrometer design include remote sensing from both space and aircraft platforms as well as groundbased astronomical observations.
Faye, Mbaye; Bordessoule, Michel; Kanouté, Brahim; Brubach, Jean-Blaise; Roy, Pascale; Manceron, Laurent
2016-06-01
When using bright, small effective size sources, such as synchrotron radiation light beam, for broadband spectroscopy at spectral or spatial high resolution for mid-IR FTIR measurements, a marked detectivity improvement can be achieved by setting up a device matching the detector optical étendue to that of the source. Further improvement can be achieved by reducing the background unmodulated flux and other intrinsic noise sources using a lower temperature cryogen, such as liquid helium. By the combined use of cooled apertures, cold reimaging optics, filters and adapted detector polarization, and preamplification electronics, the sensitivity of a HgCdTe photoconductive IR detector can be improved by a significant factor with respect to standard commercial devices (more than one order of magnitude on average over 6-20 μm region) and the usable spectral range extended to longer wavelengths. The performances of such an optimized detector developed on the AILES Beamline at SOLEIL are presented here.
NASA Astrophysics Data System (ADS)
Dai, Jingmin; Wang, Xinbei; Yuan, Guibin
2005-01-01
A new spectral emissivity measurement system has been developed at Harbin Institute of Technology (HIT) by using a Fourier transform infrared (FTIR) spectrometer. The spectral range between 0.6 and 25 µm was covered by a photovoltaic HgCdTe and a silicon photodiode detector. A SiC heater with a black hole was employed for heating the sample. The temperature of the sample can be controlled in a range between 60 and 1500°C with an error of less than 1°C. The system was calibrated against two high quality reference blackbodies: a low temperature heat-pipe blackbody operated in the temperature range between 60°C and 300°C and a high temperature blackbody with SiC heater operated in the temperature range between 300°C and 1500°C. Several tests were done for this new system. The estimated uncertainty of emissivity measurement is better than 3%.
VizieR Online Data Catalog: Spectroscopy of 104 objects in the ONC (Ingraham+, 2014)
NASA Astrophysics Data System (ADS)
Ingraham, P.; Albert, L.; Doyon, R.; Artigau, E.
2016-03-01
In 2003 December, we obtained six nights (on CFHT to perform MOS observations of faint objects in the central region of the Orion Trapezium cluster. The observations used the infrared imager and multi-object spectrograph SIMON (Spectrometre Infrarouge de Montreal). The optical design is fully achromatic between 0.8 and 2.5μm and features a HAWAII-I 1024*1024 HgCdTe detector with an image scale of 0.2'' on CFHT. SIMON utilizes a low-dispersion Amici prism enabling multi-object low-resolution (R~30) spectroscopy over the wavelength range of 0.9-2.4μm. The slit width, in the spectral direction, was chosen to be 0.6'' (3pixels) resulting in a spectral resolution of R~30. In total, spectra for 240 point sources were obtained. Here, we present only the 104 objects (see Table5) with low-extinction (AV<8) spectra having well constrained spectral types. (2 data files).
Liu, Jinbao; Zhang, Yang; Wang, Huanyuan; Du, Yichun
2018-06-15
The estimation of soils heavy metal content can reflect the impending surroundings of surface, which lays theoretical foundation for using covered vegetation to monitor environment and investigate resource. In this study, the contents of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb in 44 soil samples were collected from Fufeng County, Yangling County and Wugong County, Shaanxi Province and were used as data sources. ASD FieldSpec HR (350-2500nm), and then the NOR, MSC and SNV of the reflectance were pretreated, the first deviation, second deviation and reflectance reciprocal logarithmic transformation were carried out. The optimal spectroscopy estimation model of nine heavy metal elements of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb was established by regression method. Comparing the diffuse reflectance characteristics of different heavy metal contents and the effect of different pretreatment methods on the establishment of soil heavy metal spectral inversion model. The results of chemical analysis show that there was a serious Hg pollution in the study area, and the Cd content was close to the critical value. The results show that: (1) NOR, MSC and SNV were adopted for the acquisition of visible near-infrared. Combining differential transformation can improve the information of heavy metal elements in the soil, and use the correlation band energy Significantly improve the stability and predictability of the model. (2) The modeling accuracy of the optimal model of nine heavy metal spectra of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb by PLSR method were 0.70, 0.79, 0.69, 0.81, 0.86, 0.58, 0.55, 0.99, 0.62. (3) The optimal estimation model of different elements using different treatment methods has better stability and higher precision, and can realize the rapid prediction of nine kinds of heavy metal elements in this region. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Jinbao; Zhang, Yang; Wang, Huanyuan; Du, Yichun
2018-06-01
The estimation of soils heavy metal content can reflect the impending surroundings of surface, which lays theoretical foundation for using covered vegetation to monitor environment and investigate resource. In this study, the contents of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb in 44 soil samples were collected from Fufeng County, Yangling County and Wugong County, Shaanxi Province and were used as data sources. ASD FieldSpec HR (350-2500 nm), and then the NOR, MSC and SNV of the reflectance were pretreated, the first deviation, second deviation and reflectance reciprocal logarithmic transformation were carried out. The optimal spectroscopy estimation model of nine heavy metal elements of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb was established by regression method. Comparing the diffuse reflectance characteristics of different heavy metal contents and the effect of different pretreatment methods on the establishment of soil heavy metal spectral inversion model. The results of chemical analysis show that there was a serious Hg pollution in the study area, and the Cd content was close to the critical value. The results show that: (1) NOR, MSC and SNV were adopted for the acquisition of visible near-infrared. Combining differential transformation can improve the information of heavy metal elements in the soil, and use the correlation band energy Significantly improve the stability and predictability of the model. (2) The modeling accuracy of the optimal model of nine heavy metal spectra of Cr, Mn, Ni, Cu, Zn, As, Cd, Hg and Pb by PLSR method were 0.70, 0.79, 0.69, 0.81, 0.86, 0.58, 0.55, 0.99, 0.62. (3) The optimal estimation model of different elements using different treatment methods has better stability and higher precision, and can realize the rapid prediction of nine kinds of heavy metal elements in this region.
Microscopic fluorescence spectral analysis of basal cell carcinomas
NASA Astrophysics Data System (ADS)
He, Qingli; Lui, Harvey; Zloty, David; Cowan, Bryce; Warshawski, Larry; McLean, David I.; Zeng, Haishan
2007-05-01
Background and Objectives. Laser-induced autofluorescence (LIAF) is a promising tool for cancer diagnosis. This method is based on the differences in autofluorescence spectra between normal and cancerous tissues, but the underlined mechanisms are not well understood. The objective of this research is to study the microscopic origins and intrinsic fluorescence properties of basal cell carcinoma (BCC) for better understanding of the mechanism of in vivo fluorescence detection and margin delineation of BCCs on skin patients. A home-made micro- spectrophotometer (MSP) system was used to image the fluorophore distribution and to measure the fluorescence spectra of various microscopic structures and regions on frozen tissue sections. Materials and Methods. BCC tissue samples were obtained from 14 patients undergoing surgical resections. After surgical removal, each tissue sample was immediately embedded in OCT medium and snap-frozen in liquid nitrogen. The frozen tissue block was then cut into 16-μm thickness sections using a cryostat microtome and placed on microscopic glass slides. The sections for fluorescence study were kept unstained and unfixed, and then analyzed by the MSP system. The adjacent tissue sections were H&E stained for histopathological examination and also served to help identify various microstructures on the adjacent unstained sections. The MSP system has all the functions of a conventional microscope, plus the ability of performing spectral analysis on selected micro-areas of a microscopic sample. For tissue fluorescence analysis, 442nm He-Cd laser light is used to illuminate and excite the unstained tissue sections. A 473-nm long pass filter was inserted behind the microscope objective to block the transmitted laser light while passing longer wavelength fluorescence signal. The fluorescence image of the sample can be viewed through the eyepieces and also recorded by a CCD camera. An optical fiber is mounted onto the image plane of the photograph port of the microscope to collect light from a specific micro area of the sample. The collected light is transmitted via the fiber to a disperserve type CCD spectrometer for spectral analysis. Results. The measurement results showed significant spectral differences between normal and cancerous tissues. For normal tissue regions, the spectral results agreed with our previous findings on autofluorescence of normal skin sections. For the cancerous regions, the epidermis showed very weak fluorescence signal, while the stratum corneum exhibited fluorescence emissions peaking at about 510 nm. In the dermis, the basal cell island and a band of surrounding areas showed very weak fluorescence signal, while distal dermis above and below the basal cell island showed greater fluorescence signal but with different spectral shapes. The very weak autofluorescence from the basal cell island and its surrounding area may be attributed to their degenerative properties that limited the production of collagens. Conclusions. The obtained microscopic results very well explain the in vivo fluorescence properties of BCC lesions in that they have decreased fluorescence intensity compared to the surrounding normal skin. The intrinsic spectra of various microstructures and the microscopic fluorescence images (corresponding fluorophore distribution in tissue) obtained in this study will be used for further theoretical modeling of in vivo fluorescence spectroscopy and imaging of skin cancers.
Apparatus and system for multivariate spectral analysis
Keenan, Michael R.; Kotula, Paul G.
2003-06-24
An apparatus and system for determining the properties of a sample from measured spectral data collected from the sample by performing a method of multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used by a spectrum analyzer to process X-ray spectral data generated by a spectral analysis system that can include a Scanning Electron Microscope (SEM) with an Energy Dispersive Detector and Pulse Height Analyzer.
NASA Astrophysics Data System (ADS)
Ovchinnikov, O. V.; Smirnov, M. S.; Shapiro, B. I.; Dedikova, A. O.; Shatskikh, T. S.
2015-11-01
We have found spectroscopic manifestations of hybrid association in mixtures of CdS colloidal quantum dots with an average size of 2.5-4.2 nm with J-aggregates of pyridinium salt of the 3,3'-di-(γ- sulfopropyl)-9-ethyl-4,5,4',5'-dibenzo-thiacarbocyanine betaine dye that were prepared by the sol-gel method in gelatin. Observed changes of the spectral properties of J-aggregates of dye molecules due to their hybrid association with CdS quantum dots are ensured by steric transformations of dye molecules, which lead to the formation of luminescent trans-J-aggregates. The hybrid association is accompanied by the quenching of the recombination luminescence band of CdS quantum dots (540-640 nm) and by an increase in the luminescence intensity of J-aggregates of dye molecules (670-680 nm). This regularity becomes enhanced with an increase in the ratio of the number of dye molecules to the number of quantum dots [ n dye]: [ n QD] and in the degree of overlap between the luminescence spectrum of quantum dots and the absorption spectrum of J-aggregates, which indicates that there is a resonant nonradiative transfer of the electronic excitation energy from recombination luminescence centers in CdS quantum dots to trans-J-aggregates of dye molecules conjugated to them.
NASA Astrophysics Data System (ADS)
Takamasu, Kiyoshi; Takahashi, Satoru; Kawada, Hiroki; Ikota, Masami
2018-03-01
LER (Line Edge Roughness) and LWR (Line Width Roughness) of the semiconductor device are an important evaluation scale of the performance of the device. Conventionally, LER and LWR is evaluated from CD-SEM (Critical Dimension Scanning Electron Microscope) images. However, CD-SEM measurement has a problem that high frequency random noise is large, and resolution is not sufficiently high. For random noise of CD-SEM measurement, some techniques are proposed. In these methods, it is necessary to set parameters for model and processing, and it is necessary to verify the correctness of these parameters using reference metrology. We have already proposed a novel reference metrology using FIB (Focused Ion Beam) process and planar-TEM (Transmission Electron Microscope) method. In this study, we applied the proposed method to three new samples such as SAQP (Self-Aligned Quadruple Patterning) FinFET device, EUV (Extreme Ultraviolet Lithography) conventional resist, and EUV new material resist. LWR and PSD (Power Spectral Density) of LWR are calculated from the edge positions on planar-TEM images. We confirmed that LWR and PSD of LWR can be measured with high accuracy and evaluated the difference by the proposed method. Furthermore, from comparisons with PSD of the same sample by CD-SEM, the validity of measurement of PSD and LWR by CD-SEM can be verified.
The Tissue Analysis Core (TAC) within the AIDS and Cancer Virus Program will process, embed, and perform microtomy on fixed tissue samples presented in ethanol. CD4 (DAB) and CD68/CD163 (FastRed) double immunohistochemistry will be performed, in whic
Hybrid least squares multivariate spectral analysis methods
Haaland, David M.
2004-03-23
A set of hybrid least squares multivariate spectral analysis methods in which spectral shapes of components or effects not present in the original calibration step are added in a following prediction or calibration step to improve the accuracy of the estimation of the amount of the original components in the sampled mixture. The hybrid method herein means a combination of an initial calibration step with subsequent analysis by an inverse multivariate analysis method. A spectral shape herein means normally the spectral shape of a non-calibrated chemical component in the sample mixture but can also mean the spectral shapes of other sources of spectral variation, including temperature drift, shifts between spectrometers, spectrometer drift, etc. The shape can be continuous, discontinuous, or even discrete points illustrative of the particular effect.
Analysis of spectrally resolved autofluorescence images by support vector machines
NASA Astrophysics Data System (ADS)
Mateasik, A.; Chorvat, D.; Chorvatova, A.
2013-02-01
Spectral analysis of the autofluorescence images of isolated cardiac cells was performed to evaluate and to classify the metabolic state of the cells in respect to the responses to metabolic modulators. The classification was done using machine learning approach based on support vector machine with the set of the automatically calculated features from recorded spectral profile of spectral autofluorescence images. This classification method was compared with the classical approach where the individual spectral components contributing to cell autofluorescence were estimated by spectral analysis, namely by blind source separation using non-negative matrix factorization. Comparison of both methods showed that machine learning can effectively classify the spectrally resolved autofluorescence images without the need of detailed knowledge about the sources of autofluorescence and their spectral properties.
A search for peculiar stars in the open cluster Hogg 16
NASA Astrophysics Data System (ADS)
Cariddi, Stefano; Azatyan, Naira M.; Kurfürst, Petr; Štofanová, Lýdia; Netopil, Martin; Paunzen, Ernst; Pintado, Olga I.; Aidelman, Yael J.
2018-01-01
The study of chemically peculiar (CP) stars in open clusters provides valuable information about their evolutionary status. Their detection can be performed using the Δa photometric system, which maps a characteristic flux depression at λ ∼ 5200 Å. This paper aims at studying the occurrence of CP stars in the earliest stages of evolution of a stellar population by applying this technique to Hogg 16, a very young Galactic open cluster ( ∼ 25 Myr). We identified several peculiar candidates: two B-type stars with a negative Δa index (CD - 60 4701, CPD - 60 4706) are likely emission-line (Be) stars, even though spectral measurements are necessary for a proper classification of the second one; a third object (CD - 60 4703), identified as a Be candidate in literature, appears to be a background B-type supergiant with no significant Δa index, which does not rule out the possibility that it is indeed peculiar as the normality line of Δa for supergiants has not been studied in detail yet. A fourth object (CD - 60 4699) appears to be a magnetic CP star of 8 M⊙, but obtained spectral data seem to rule out this hypothesis. Three more magnetic CP star candidates are found in the domain of early F-type stars. One is a probable nonmember and close to the border of significance, but the other two are probably pre-main sequence cluster objects. This is very promising, as it can lead to very strong constraints to the diffusion theory. Finally, we derived the fundamental parameters of Hogg 16 and provide for the first time an estimate of its metal content.
Ensafi, Ali A; Nasr-Esfahani, Parisa; Rezaei, B
2017-12-15
In this work, molecularly imprinted polymers (MIPs) were used on the surface of cadmium telluride quantum dots (CdTe QDs) for the simultaneous determination of folic acid (FA) and methotrexate (MTX). For this purpose, two different sizes of CdTe QDs with emission peaks in the yellow (QD Y ) and orange (QD O ) spectral regions were initially synthesized and capped with MIPs. FA and MTX were used as templates for the synthesis of the two composites and designated as QD Y -MIPs and QD O -MIPs, respectively. Fourier transform infrared spectroscopy, transmission electron microscopy, and fluorescence spectroscopy were employed to characterize the composites. QD Y -MIPs and QD O -MIPs were then mixed (to form QDs-MIPs) and excited at identical excitation wavelengths; they emitted two different emission wavelengths without any spectral overlap. The fluorescence signals of QD Y -MIPs and QD O -MIPs diminished in intensity with increasing concentration of the corresponding template molecules. Under optimal conditions, the dynamic range was 0.5-20 μmol L -1 for FA and MTX, and the detection limits for FA and MTX were 32.0 nmol L -1 and 34.0 nmol L -1 , respectively. The reproducibility of the method was checked for 12.5 μmol L -1 of FA and MTX to find RSD values of 4.2% and 6.3%, respectively. Finally, the applicability of the method was checked using human blood plasma samples. Results indicated the successful application of the method as a fluorescent probe for the rapid and simultaneous detection of FA and MTX in real samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Gladys, Granero; Claudia, Garnero; Marcela, Longhi
2003-11-01
A novel complexation of sulfisoxazole with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) was studied. Two systems were used: binary complexes prepared with HP-beta-CD and multicomponent system (HP-beta-CD and the basic compound triethanolamine (TEA)). Inclusion complex formation in aqueous solutions and in solid state were investigated by the solubility method, thermal analysis (differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA)), Fourier-transform infrared spectroscopy (FT-IR) and dissolution studies. The solid complexes of sulfisoxazole were prepared by freeze-drying the homogeneous concentrated aqueous solutions in molar ratios of sulfisoxazole:HP-beta-CD 1:1 and 1:2, and sulfisoxazole:TEA:HP-beta-CD 1:1:2. FT-IR and thermal analysis showed differences among sulfisoxazole:HP-beta-CD and sulfisoxazole:TEA:HP-beta-CD and their corresponding physical mixtures and individual components. The HP-beta-CD solubilization of sulfisoxazole could be improved by ionization of the drug molecule through pH adjustments. However, larger improvements of the HP-beta-CD solubilization are obtained when multicomponent systems are used, allowing to reduce the amount of CD necessary to prepare the target formulation.
HgCdTe Photoconductive Mixers for 2-8 THz
NASA Technical Reports Server (NTRS)
Betz, A. L.; Boreiko, R. T.; Sivananthan, S.; Ashokan, R.
2001-01-01
Heterodyne spectroscopy has been taken to wavelengths as short as 63 micrometers with Schottky-diode mixers. Schottkys, however, are relatively insensitive compared to superconducting mixers such as the hot-electron microbolometer (HEB), which has an effective quantum efficiency of 3% at 120 micrometers (2.5 THz). Although HEB sensitivities are bound to improve, there will always be losses associated with antenna coupling of radiation into sub-micron size devices. Another approach to far infrared (FIR) mixer design is to use a photoconductive device which can be made much larger than a wavelength, and thus act as its own antenna. For example, HgCdTe photodiodes have been used as mixers in the lambda = 10 micrometers band for over 25 years, with sensitivities now only a factor of 2 from the quantum-noise-limit. HgCdTe can also be applied at FIR wavelengths, but surprisingly little work has been done to date. The exception is the pioneering work of Spears and Kostiuk and Spears, who developed HgCdTe photomixers for the 20-120 micrometer region. The spectral versatility of the HgCdTe alloy is well recognized for wavelengths as long as 8-20 micrometers. What is not so recognized, however, is that theoretically there is no long wavelength limit for appropriately composited HgCdTe. Although Spears successfully demonstrated a photoconductive response from HgCdTe at 120 micrometers, this initial effort was apparently never followed up, in part because of the difficulty of controlling the HgCdTe alloy composition with liquid-phase-epitaxy (LPE) techniques. With the availability of precise molecular-beam-epitaxy (MBE) since the early 1990's, it is now appropriate to reconsider HgCdTe for detector applications longward of lambda = 20 micrometers. We recently initiated an effort to fabricate detectors and mixers using II-VI materials for FIR wavelengths. Of particular interest are device structures called superlattices, which offer a number of advantages for high sensitivity direct detectors and very long wavelength heterodyne mixers.
NASA Astrophysics Data System (ADS)
Lavrik, N. L.; Mulloev, N. U.
2018-02-01
The methods of absorption and fluorescence were used to study the efficiency of the interaction between salicylic acid derivatives SAD (neutral SA form and SA monoanion) and Cd2 + ions (in CdBr2 salt) within the range pH = 1.5 ÷ 8. The efficiency was determined from the change in both the absorption band contour and the fluorescence intensity of various SAD forms. It has been established that depending on the SAD form, the addition of CdBr2 to a starting solution leads to the formation of additional absorption for both the shorter wave lengths in the absorption spectrum of the neutral form (at pH < 3) and the longer wave lengths in the absorption spectrum for the HSal- monoanion (at pH > 4). In the fluorescence spectra, the intensity was observed to increase for the neutral SAD form (at pH < 3) and to decrease for the HSal- monoanion (at pH > 4) after addition of CdBr2. The spectral changes were interpreted in the framework of common notions about the effect of three physicochemical factors that determine the interaction between the SAD and the Cd2 + ion and affect the parameters of absorption and fluorescence spectra. These factors are: (1) the decrease in pH after addition of CdBr2 to the SAD solution, (2) the decrease in the efficiency of the H-bonding of SAD molecules to the water ones, and (3) the existence of electrostatic ion-ion interaction between the HSal- monoanion and the Cd2 + ion. The bimolecular fluorescence quenching constants Kq of HSal- monoanion fluorescence quenching by the Cd2 + ion appeared to be substantially less than those of the quenching which would follow either the dynamic (diffusion) or the concentration (static) mechanisms.
CD147/EMMPRIN overexpression and prognosis in cancer: A systematic review and meta-analysis
Xin, Xiaoyan; Zeng, Xianqin; Gu, Huajian; Li, Min; Tan, Huaming; Jin, Zhishan; Hua, Teng; Shi, Rui; Wang, Hongbo
2016-01-01
CD147/EMMPRIN (extracellular matrix metalloproteinase inducer) plays an important role in tumor progression and a number of studies have suggested that it is an indicator of tumor prognosis. This current meta-analysis systematically reevaluated the predictive potential of CD147/EMMPRIN in various cancers. We searched PubMed and Embase databases to screen the literature. Fixed-effect and random-effect meta-analytical techniques were used to correlate CD147 expression with outcome measures. A total of 53 studies that included 68 datasets were eligible for inclusion in the final analysis. We found a significant association between CD147/EMMPRIN overexpression and adverse tumor outcomes, such as overall survival, disease-specific survival, progression-free survival, metastasis-free survival or recurrence-free survival, irrespective of the model analysis. In addition, CD147/EMMPRIN overexpression predicted a high risk for chemotherapy drugs resistance. CD147/EMMPRIN is a central player in tumor progression and predicts a poor prognosis, including in patients who have received chemo-radiotherapy. Our results provide the evidence that CD147/EMMPRIN could be a potential therapeutic target for cancers. PMID:27608940
Analytical methods to determine the comparative DNA binding studies of curcumin-Cu(II) complexes
NASA Astrophysics Data System (ADS)
Rajesh, Jegathalaprathaban; Rajasekaran, Marichamy; Rajagopal, Gurusamy; Athappan, Periakaruppan
2012-11-01
DNA interaction studies of two mononuclear [1:1(1); 1:2(2)] copper(II) complexes of curcumin have been studied. The interaction of these complexes with CT-DNA has been explored by physical methods to propose modes of DNA binding of the complexes. Absorption spectral titrations of complex 1 with CT-DNA shows a red-shift of 3 nm with the DNA binding affinity of Kb, 5.21 × 104 M-1 that are higher than that obtained for 2 (red-shift, 2 nm; Kb, 1.73 × 104 M-1) reveal that the binding occurs in grooves as a result of the interaction is via exterior phosphates. The CD spectra of these Cu(II) complexes show a red shift of 3-10 nm in the positive band with increase in intensities. This spectral change of induced CD due to the hydrophobic interaction of copper complexes with DNA is the characteristic of B to A conformational change. The EB displacement assay also reveals the same trend as observed in UV-Vis spectral titration. The addition of complexes 1 and 2 to the DNA bound ethidium bromide (EB) solutions causes an obvious reduction in emission intensities indicating that these complexes competitively bind to DNA with EB. The positive shift of both the Epc and E0' accompanied by reduction of peak currents in differential pulse voltammogram (DPV), upon adding different concentrations of DNA to the metal complexes, are obviously in favor of strong binding to DNA. The super coiled plasmid pUC18 DNA cleavage ability of Cu(II) complexes in the presence of reducing agent reveals the single strand DNA cleavage (ssDNA) is observed. The hydroxyl radical (HOrad ) and the singlet oxygen are believed to be the reactive species responsible for the cleavage.
NASA Astrophysics Data System (ADS)
Velicu, S.; Buurma, C.; Bergeson, J. D.; Kim, Tae Sung; Kubby, J.; Gupta, N.
2014-05-01
Imaging spectrometry can be utilized in the midwave infrared (MWIR) and long wave infrared (LWIR) bands to detect, identify and map complex chemical agents based on their rotational and vibrational emission spectra. Hyperspectral datasets are typically obtained using grating or Fourier transform spectrometers to separate the incoming light into spectral bands. At present, these spectrometers are large, cumbersome, slow and expensive, and their resolution is limited by bulky mechanical components such as mirrors and gratings. As such, low-cost, miniaturized imaging spectrometers are of great interest. Microfabrication of micro-electro-mechanicalsystems (MEMS)-based components opens the door for producing low-cost, reliable optical systems. We present here our work on developing a miniaturized IR imaging spectrometer by coupling a mercury cadmium telluride (HgCdTe)-based infrared focal plane array (FPA) with a MEMS-based Fabry-Perot filter (FPF). The two membranes are fabricated from silicon-oninsulator (SOI) wafers using bulk micromachining technology. The fixed membrane is a standard silicon membrane, fabricated using back etching processes. The movable membrane is implemented as an X-beam structure to improve mechanical stability. The geometries of the distributed Bragg reflector (DBR)-based tunable FPFs are modeled to achieve the desired spectral resolution and wavelength range. Additionally, acceptable fabrication tolerances are determined by modeling the spectral performance of the FPFs as a function of DBR surface roughness and membrane curvature. These fabrication non-idealities are then mitigated by developing an optimized DBR process flow yielding high-performance FPF cavities. Zinc Sulfide (ZnS) and Germanium (Ge) are chosen as the low and the high index materials, respectively, and are deposited using an electron beam process. Simulations are presented showing the impact of these changes and non-idealities in both a device and systems level.
The Ring System of Saturn as Seen by Cassini-VIMS (Invited)
NASA Astrophysics Data System (ADS)
Filacchione, G.; Ciarniello, M.; Capaccioni, F.
2015-08-01
Since 2004 the Visual and Infrared Mapping Spectrometer (VIMS) aboard Cassini has acquired numerous hyperspectral mosaics in the 0.35-5.1 μm spectral range of Saturn's main rings in very different illumination and viewing geometries. These observations have allowed us to infer the ring particles physical properties and composition: water ice abundance is estimated through the 1.25-1.5-2.0 μm band depths, chromophores distribution is derived from visible spectral slopes while organic material is traced by the aliphatic compounds signature at 3.42 μm which appears stronger on CD and C ring than on A-B rings (Filacchione et al., 2014). Observed reflectance spectra are fitted with a spectrophotometric model based on Montecarlo ray-tracing with the scope to infer particles composition while disentangling photometric effects (caused by multiple scattering, opposition surge and forward scattering) which depend on illumination/viewing geometries. Spectral bond albedo for different regions of the rings has been best-fitted using Hapke's radiative transfer modeling (Ciarniello et al, 2011) by choosing different mixtures of water ice, tholin, and amorphous carbon particles populations. While tholin distribution seems to be fairly constant across the rings, the amorphous carbon appears anti-correlated with optical depth. Moreover, dark material contamination is less effective on densest regions, where the more intense rejuvenation processes occur, in agreement with the ballistic transport theory (Cuzzi and Estrada,1998). Finally, the 3.6 μm continuum peak wavelength is used to infer particles temperature, which is anti-correlated with the albedo and the optical depth (tau): low-albedo/low-tau C ring and CD have higher temperatures than A-B rings where albedo and tau are high. This trend matches direct temperature measurements by CIRS (Spilker et al., 2013).
NASA Astrophysics Data System (ADS)
Lilly, T.; Fritze-v. Alvensleben, U.; de Grijs, R.
2005-05-01
We present mathematically advanced tools for the determination of age, metallicity, and mass of old Globular Clusters (CGs) using both broad-band colors and spectral indices, and we present their application to the Globular Cluster Systems (GCSs) of elliptical galaxies. Since one of the most intriguing questions of today's astronomy aims at the evolutionary connection between (young) violently interacting galaxies at high-redshift and the (old) elliptical galaxies we observe nearby, it is necessary to reveal the possibly violent star-formation history of these old galaxies. By means of evolutionary synthesis models, we can show that, using the integrated light of a galaxy's (composite) stellar content alone, it is impossible to date (and, actually, to identify) even very strong starbursts if these events took place more than two or three Gyr ago. However, since large and violent starbursts are associated with the formation of GCs, GCSs are very good tracers of the most violent starburst events in the history of their host galaxies. Using our well-established Göttingen SED (Spectral Energy Distribution) analysis tool, we can reveal the age, metallicity, mass (and possibly extinction) of GCs by comparing the observations with an extensive grid of SSP model colors. This is done in a statistically advanced and reasonable way, including their 1 σ uncertainties. However, since for all colors the evolution slows down considerably at ages older than about 8 Gyr, even with several passbands and a long wavelength base line, the results are severely uncertain for old clusters. Therefore, we incorporated empirical calibrations for Lick indices in our models and developed a Lick indices analysis tool that works in the same way as the SED analysis tool described above. We compare the theoretical possibilities and limitations of both methods as well as their results for the example of the cD galaxy NGC 1399, for which both multi-color observations and, for a subsample of clusters, spectral indices are available, and address implications for the nature and origin of the observed bimodal color distribution.
Rawson, T M; Dubb, S; Pozniak, A; Kelleher, W P; Mandalia, S; Gazzard, B; Barber, T J
2015-02-01
Studies have suggested CD8 lymphocytes may be a possible marker for inflammation, which is believed to be a contributing factor to neurocognitive impairment. Individuals enrolled in the MSM Neurocog Study were analysed. Those with depression, anxiety or mood disorders were excluded. Individuals with neurocognitive impairment were identified using the Brief NeuroCognitive Screen and compared to those with normal scores. CD4 and CD8 T cell values and CD4:CD8 ratios were compared between groups. In all, 144 men, aged 18-50 years, were included in the analysis. Twenty were diagnosed with neurocognitive impairment. We were unable to identify any significant difference between current, nadir or peak CD4 and CD8 counts. CD4:CD8 ratios and CD4:CD8 ratio inversion (<1) were also found to be similar between both groups. However, neurocognitive impairment subjects were 8% more likely to have inversion of CD4:CD8 ratio and higher median peak CD8 cell counts reported compared to non-impaired subjects. Analysis of data from the MSM Neurocog Study, demonstrated trends in peripheral CD8 counts and CD4:CD8 ratios. However, we are unable to demonstrate any significant benefit. Plasma biomarkers of neurocognitive impairment in HIV-infected subjects would be of great benefit over current methods of invasive CSF analysis and technical neuroimaging used in the diagnosis of neurocognitive impairment. Future, prospective, longitudinal work with large numbers of neurocognitive impairment subjects is required to further investigate the role of peripheral CD8 T cells as markers of neurocognitive impairment. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Gubendran, Ammavasi; Kesavan, Mookkandi Palsamy; Ayyanaar, Srinivasan; Mitu, Liviu; Athappan, Periyakaruppan; Rajesh, Jegathalaprathaban
2017-06-01
New Schiff base complexes [Cu(L1)Cl] (1), [Ni(L1)Cl] (2), [Zn(L1)Cl] (3), and [Fe(L2)H2OCl] (4) {L1 = (4E)-3-(2-hydroxybenzylidene)-4-(2-hydroxyphenylimino)pentan-2-one, L2 = 2,2‧-(1E,1‧E)-(3-(2-hydroxybenzylidene)-pentane-2,4-diylidene)bis(azan-1-yl-1 idene)diphenol} have been synthesized and characterized by elemental analysis, UV-Vis, IR, FAB-mass, EPR, spectral studies and electrochemical studies, the ligands L1 &L2 were characterized by 1H and 13C NMR spectra. Complex 1 show a visible spectral d-d band near 600 nm and display cyclic voltammetric quasireversible response for the Cu(II)/Cu(I) couple vs Ag/AgCl in DMSO. The EPR spectrum of 1 show g‖ > g⊥ suggesting a square planar geometry around copper with dx2 - y2 as the ground state. The mass spectral results have confirmed the proposed structure for complexes 1-4. DNA binding properties of these complexes 1-4 have been investigated by absorption titrations, cyclic voltammetric studies and circular dichroism studies. On titration with DNA, the complexes 1-4 show hypochromism at the MLCT band (13-31%) with a red shift of 1-8 nm in the electronic spectrum and positive shift of voltammetric E1/2 in the CV studies are in favour of intercalative binding. CD spectra of 1 showed an increase in molar ellipticity (θ278) of the positive band with a minor red shift indicating the transition of B-form of DNA to A like form. DNA cleavage studies of complexes 1 and 4 with pUC18 DNA were studied by gel electrophoresis and complex 4 cleaves supercoiled pUC18 DNA in an oxidative manner in the presence of H2O2 and on photo irradiation at 312 nm.
Node-pore sensing enables label-free surface-marker profiling of single cells.
Balakrishnan, Karthik R; Whang, Jeremy C; Hwang, Richard; Hack, James H; Godley, Lucy A; Sohn, Lydia L
2015-03-03
Flow cytometry is a ubiquitous, multiparametric method for characterizing cellular populations. However, this method can grow increasingly complex with the number of proteins that need to be screened simultaneously: spectral emission overlap of fluorophores and the subsequent need for compensation, lengthy sample preparation, and multiple control tests that need to be performed separately must all be considered. These factors lead to increased costs, and consequently, flow cytometry is performed in core facilities with a dedicated technician operating the instrument. Here, we describe a low-cost, label-free microfluidic method that can determine the phenotypic profiles of single cells. Our method employs Node-Pore Sensing to measure the transit times of cells as they interact with a series of different antibodies, each corresponding to a specific cell-surface antigen, that have been functionalized in a single microfluidic channel. We demonstrate the capabilities of our method not only by screening two acute promyelocytic leukemia human cells lines (NB4 and AP-1060) for myeloid antigens, CD13, CD14, CD15, and CD33, simultaneously, but also by distinguishing a mixture of cells of similar size—AP-1060 and NALM-1—based on surface markers CD13 and HLA-DR. Furthermore, we show that our method can screen complex subpopulations in clinical samples: we successfully identified the blast population in primary human bone marrow samples from patients with acute myeloid leukemia and screened these cells for CD13, CD34, and HLA-DR. We show that our label-free method is an affordable, highly sensitive, and user-friendly technology that has the potential to transform cellular screening at the benchside.
NASA Technical Reports Server (NTRS)
Sabol, Donald E., Jr.; Adams, John B.; Smith, Milton O.
1992-01-01
The conditions that affect the spectral detection of target materials at the subpixel scale are examined. Two levels of spectral mixture analysis for determining threshold detection limits of target materials in a spectral mixture are presented, the cases where the target is detected as: (1) a component of a spectral mixture (continuum threshold analysis) and (2) residuals (residual threshold analysis). The results of these two analyses are compared under various measurement conditions. The examples illustrate the general approach that can be used for evaluating the spectral detectability of terrestrial and planetary targets at the subpixel scale.
Xu, Hua; Yu, Changjiang; Xia, Xinli; Li, Mingliang; Li, Huiguang; Wang, Yu; Wang, Shumin; Wang, Congpeng; Ma, Yubin; Zhou, Gongke
2018-01-01
Cadmium (Cd) is a detrimental environmental pollutant. Duckweeds have been considered promising candidates for Cd phytoremediation. Although many physiological studies have been conducted, the molecular mechanisms underlying Cd hyperaccumulation in duckweeds are largely unknown. In this study, clone 6001 of Landoltia punctata, which showed high Cd tolerance, was obtained by large-scale screening of over 200 duckweed clones. Subsequently, its growth, Cd flux, Cd accumulation, and Cd distribution characteristics were investigated. To further explore the global molecular mechanism, a comprehensive transcriptome analysis was performed. For RNA-Seq, samples were treated with 20 μM CdCl 2 for 0, 1, 3, and 6 days. In total, 9,461, 9,847, and 9615 differentially expressed unigenes (DEGs) were discovered between Cd-treated and control (0 day) samples. DEG clustering and enrichment analysis identified several biological processes for coping with Cd stress. Genes involved in DNA repair acted as an early response to Cd, while RNA and protein metabolism would be likely to respond as well. Furthermore, the carbohydrate metabolic flux tended to be modulated in response to Cd stress, and upregulated genes involved in sulfur and ROS metabolism might cause high Cd tolerance. Vacuolar sequestration most likely played an important role in Cd detoxification in L. punctata 6001. These novel findings provided important clues for molecular assisted screening and breeding of Cd hyperaccumulating cultivars for phytoremediation. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ullrich, B.; Schroeder, R.
2001-08-01
Thin (10 µm) film CdS on Pyrex® formed by spray pyrolysis is excited below the gap at 804 nm with 200 fs laser pulses at room temperature. Excitation intensities up to 250 GW cm-2 evoke green bandgap emission due to two-photon transitions. This two-photon photoluminescence does not show a red emission contribution in contrast to the single-photon excited emission, which is dominated by broad emission in the red spectral range. It is demonstrated that two-photon excitation causes photo-induced bandgap narrowing due to Debye screening. At 250 GW cm-2 bandgap narrowing of 47 meV is observed, which corresponds to an excited electron density of 1.6×1018 cm-3.
Brus, Viktor V; Pidkamin, Leonid J; Ilashchuk, Maria I; Maryanchuk, Pavlo D
2014-04-01
We report on the analysis of optical, polarimetric, and electrical properties of propolis films and hybrid biomaterial-inorganic heterojunctions based on them. It was shown that the material of the propolis films belongs to wide-bandgap optically active substances with the light-scattering centers, which possess complex optical properties. The values of the specific resistance ρ(P)=1.9·10⁷ Ω·cm and dielectric constant ε(P)=19.5 of the propolis film were determined from the spectral distribution of the real and imaginary components of its impedance at room temperature, respectively. The dominating current transport mechanisms through the hybrid bioinorganic heterojunction propolis/p-CdTe were established to be the interface-states-assisted generation-recombination within the depletion region via deep energy levels at forward bias as well as the leakage current through the shunt resistance at reverse bias.
NASA Astrophysics Data System (ADS)
Yuqing, Zhao; Yi, Xing; Lihua, Li; Juanjuan, Ma
2018-02-01
Optical sensing for cysteine (Cys) recognition is an interesting topic due to Cys biological participation. In this paper, two rhodamine-based chemosensors were designed for Cys optical sensing. For chemosensor photostability improvement, up-conversion nanocrystals were synthesized and used as excitation host. These nanocrystals were modified with a phase transfer reagent α-cyclodextrin (α-CD) to improve their compatibility with chemosensors. An efficient energy transfer from these nanocrystals to chemosensors under 980 nm radiation was observed and confirmed by spectral match analysis, energy transfer radius calculation and emission decay lifetime comparison. A direct bonding mechanism between Cys and chemosensors with bonding stoichiometry of 1:1 was established by Job's plot experiment. Given the presence of Cys, chemosensor emission was increased, showing emission turn on effect. These two chemosensors showed good selectivity, improved photostability and linear sensing response towards Cys.
Synthesis, spectral studies and biological evaluation of 2-aminonicotinic acid metal complexes.
Nawaz, Muhammad; Abbasi, Muhammad Waseem; Hisaindee, Soleiman; Zaki, Muhammad Javed; Abbas, Hira Fatima; Mengting, Hu; Ahmed, M Arif
2016-05-15
We synthesized 2-aminonicotinic acid (2-ANA) complexes with metals such as Co(II), Fe(III), Ni(II), Mn(II), Zn(II), Ag(I),Cr(III), Cd(II) and Cu(II) in aqueous media. The complexes were characterized and elucidated using FT-IR, UV-Vis, a fluorescence spectrophotometer and thermo gravimetric analysis (TGA). TGA data showed that the stoichiometry of complexes was 1:2 metal/ligand except for Ag(I) and Mn(II) where the ratio was 1:1. The metal complexes showed varied antibacterial, fungicidal and nematicidal activities. The silver and zinc complexes showed highest activity against Bacillus subtilis and Bacillus licheniformis respectively. Fusarium oxysporum was highly susceptible to nickel and copper complexes whereas Macrophomina phaseolina was completely inert to the complexes. The silver and cadmium complexes were effective against the root-knot nematode Meloidogyne javanica. Copyright © 2016 Elsevier B.V. All rights reserved.
Takemoto, Yusa; Yamamoto, Takayuki; Ikuma, Naohiko; Uchida, Yoshiaki; Suzuki, Katsuaki; Shimono, Satoshi; Takahashi, Hiroki; Sato, Nobuhiro; Oba, Yojiro; Inoue, Rintaro; Sugiyama, Masaaki; Tsue, Hirohito; Kato, Tatsuhisa; Yamauchi, Jun; Tamura, Rui
2015-07-21
An optically active amphiphilic nitroxide radical compound [(S,S,R)-], which contains a paramagnetic (2S,5S)-2,5-dimethyl-2,5-diphenylpyrrolidine-N-oxyl radical group fixed in the inner position together with a hydrophobic long alkyl chain and a hydrophilic (R)-alanine residue in the opposite terminal positions, was found to serve as a low-molecular-weight gelator in H2O to give rise to a spin-labelled physical hydrogel. Characterization of the hydrogel was performed by microscopic (SEM, TEM and AFM) techniques, XRD and SAXS measurements, and IR, UV and CD spectroscopies. The gel-sol transition temperature was determined by EPR spectral line-width (ΔHpp) analysis. Measurement of the temperature dependence of relative paramagnetic susceptibility (χrel) for the hydrogel and sol phases was achieved by means of the double-integration of VT-EPR spectra.
Selenium supplementation prevents metabolic and transcriptomic responses to cadmium in mouse lung.
Hu, Xin; Chandler, Joshua D; Fernandes, Jolyn; Orr, Michael L; Hao, Li; Uppal, Karan; Neujahr, David C; Jones, Dean P; Go, Young-Mi
2018-04-12
The protective effect of selenium (Se) on cadmium (Cd) toxicity is well documented, but underlying mechanisms are unclear. Male mice fed standard diet were given Cd (CdCl 2 , 18 μmol/L) in drinking water with or without Se (Na 2 SeO 4, 20 μmol/L) for 16 weeks. Lungs were analyzed for Cd concentration, transcriptomics and metabolomics. Data were analyzed with biostatistics, bioinformatics, pathway enrichment analysis, and combined transcriptome-metabolome-wide association study. Mice treated with Cd had higher lung Cd content (1.7 ± 0.4 pmol/mg protein) than control mice (0.8 ± 0.3 pmol/mg protein) or mice treated with Cd and Se (0.4 ± 0.1 pmol/mg protein). Gene set enrichment analysis of transcriptomics data showed that Se prevented Cd effects on inflammatory and myogenesis genes and diminished Cd effects on several other pathways. Similarly, Se prevented Cd-disrupted metabolic pathways in amino acid metabolism and urea cycle. Integrated transcriptome and metabolome network analysis showed that Cd treatment had a network structure with fewer gene-metabolite clusters compared to control. Centrality measurements showed that Se counteracted changes in a group of Cd-responsive genes including Zdhhc11, (protein-cysteine S-palmitoyltransferase), Ighg1 (immunoglobulin heavy constant gamma-1) and associated changes in metabolite concentrations. Co-administration of Se with Cd prevented Cd increase in lung and prevented Cd-associated pathway and network responses of the transcriptome and metabolome. Se protection against Cd toxicity in lung involves complex systems responses. Environmental Cd stimulates proinflammatory and profibrotic signaling. The present results indicate that dietary or supplemental Se could be useful to mitigate Cd toxicity. Published by Elsevier B.V.
Yagita, M; Huang, C L; Umehara, H; Matsuo, Y; Tabata, R; Miyake, M; Konaka, Y; Takatsuki, K
2000-05-01
We present the establishment of a natural killer (NK) leukemia cell line, designated KHYG-1, from the blood of a patient with aggressive NK leukemia, which both possessed the same p53 point mutation. The immunophenotype of the primary leukemia cells was CD2+, surface CD3-, cytoplasmic CD3epsilon+, CD7+, CD8alphaalpha+, CD16+, CD56+, CD57+ and HLA-DR+. A new cell line (KHYG-1) was established by culturing peripheral leukemia cells with 100 units of recombinant interleukin (IL)-2. The KHYG-1 cells showed LGL morphology with a large nucleus, coarse chromatin, conspicuous nucleoli, and abundant basophilic cytoplasm with many azurophilic granules. The immunophenotype of KHYG-1 cells was CD1-, CD2+, surface CD3-, cytoplasmic CD3epsilon+, CD7+, CD8alphaalpha+, CD16-, CD25-, CD33+, CD34-, CD56+, CD57-, CD122+, CD132+, and TdT-. Southern blot analysis of these cells revealed a normal germline configuration for the beta, delta, and gamma chains of the T cell receptor and the immunoglobulin heavy-chain genes. Moreover, the KHYG-1 cells displayed NK cell activity and IL-2-dependent proliferation in vitro, suggesting that they are of NK cell origin. Epstein-Barr virus (EBV) DNA was not detected in KHYG-1 cells by Southern blot analysis with a terminal repeat probe from an EBV genome. A point mutation in exon 7 of the p53 gene was detected in the KHYG-1 cells by PCR/SSCP analysis, and direct sequencing revealed the conversion of C to T at nucleotide 877 in codon 248. The primary leukemia cells also carried the same point mutation. Although the precise role of the p53 point mutation in leukemogenesis remains to be clarified, the establishment of an NK leukemia cell line with a p53 point mutation could be valuable in the study of leukemogenesis.
Gul, R.; Roy, U. N.; Camarda, G. S.; ...
2017-03-28
In this study, the properties of point defects in Cd 1–xZn xTe 1–ySe y (CZTS) radiation detectors are characterized using deep-level transient spectroscopy and compared between materials grown using two different methods, the Bridgman method and the traveling heater method. The nature of the traps was analyzed in terms of their capture cross-sections and trap concentrations, as well as their effects on the measured charge-carrier trapping and de-trapping times, and then compared for the two growth techniques. The results revealed that Se addition to CdZnTe can reduce the V Cd – concentration. In Travelling Heater Method (THM) and Bridgman Methodmore » (BM) grown CZTS detectors, besides a few similarities in the shallow and medium energy traps, there were major differences in the deep traps. It was observed that the excess-Te and lower growth-temperature conditions in THM-grown CZTS led to a complete compensation of V Cd – and two additional traps (attributed to Te i – and Te Cd ++ appearing at around E v + 0.26 eV and E c – 0.78 eV, respectively). The 1.1-eV deep trap related to large Te secondary phases was a dominant trap in the BM-grown CZTS crystals. In addition to i-DLTS data, the effects of point defects induced due to different processing techniques on the detector's resistivity, spectral response to gammas, and μτ product were determined.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gul, R.; Roy, U. N.; Camarda, G. S.
In this study, the properties of point defects in Cd 1–xZn xTe 1–ySe y (CZTS) radiation detectors are characterized using deep-level transient spectroscopy and compared between materials grown using two different methods, the Bridgman method and the traveling heater method. The nature of the traps was analyzed in terms of their capture cross-sections and trap concentrations, as well as their effects on the measured charge-carrier trapping and de-trapping times, and then compared for the two growth techniques. The results revealed that Se addition to CdZnTe can reduce the V Cd – concentration. In Travelling Heater Method (THM) and Bridgman Methodmore » (BM) grown CZTS detectors, besides a few similarities in the shallow and medium energy traps, there were major differences in the deep traps. It was observed that the excess-Te and lower growth-temperature conditions in THM-grown CZTS led to a complete compensation of V Cd – and two additional traps (attributed to Te i – and Te Cd ++ appearing at around E v + 0.26 eV and E c – 0.78 eV, respectively). The 1.1-eV deep trap related to large Te secondary phases was a dominant trap in the BM-grown CZTS crystals. In addition to i-DLTS data, the effects of point defects induced due to different processing techniques on the detector's resistivity, spectral response to gammas, and μτ product were determined.« less
White random lasing in mixture of ZnSe, CdS and CdSSe micropowders
NASA Astrophysics Data System (ADS)
Alyamani, A. Y.; Leanenia, M. S.; Alanazi, L. M.; Aljohani, M. M.; Aljariwi, A. A.; Rzheutski, M. V.; Lutsenko, E. V.; Yablonskii, G. P.
2016-03-01
Room temperature random lasing with white light emission in a mixture of AIIBVI semiconductor powders was achieved for the first time. The scattering gain media was formed by the mixture of closely packed active micron sized crystallites of ZnSe, CdS, CdSSe semiconductors. The micropowders were produced by grinding bulk crystals of each compound. Optical excitation was performed by 10-nanosecond pulses of tuned Ti:Al2O3-laser at 390 nm. The lasing in the mixture of semiconductor powders was achieved simultaneously at four wavelengths in blue, green, yellow and red spectral regions after exceeding the threshold excitation power density. A drastic integral intensity increase, spectrum narrowing and appearance of mode structure accompanied the laser action. ZnSe crystallites produce the laser light at about 460 nm while CdS particles - at about 520 nm. Two types of CdSSe semiconductor micropowders with different sulfur content lase at 580 nm and 660 nm. The threshold excitation power densities for all laser lines in the emission spectrum are approximately the same of about 0.9 MW/cm2. The sum of the emission spectrum of the mixture of the micropowders forms white light with high brightness. Lasing is due to an appearance of random feedback for amplified radiation in the active medium of closely packed light scattering crystallites. The presented results may find their applications for visualization systems, lighting technology, data transmission, medicine as biosensors and in identification systems. The key feature of random lasers is low cost of its production and possibility to be deposited on any type of surface.
Moon, Andres; Smith, Geoffrey H; Kong, Jun; Rogers, Thomas E; Ellis, Carla L; Farris, Alton B Brad
2018-02-01
Renal allograft rejection diagnosis depends on assessment of parameters such as interstitial inflammation; however, studies have shown interobserver variability regarding interstitial inflammation assessment. Since automated image analysis quantitation can be reproducible, we devised customized analysis methods for CD3+ T-cell staining density as a measure of rejection severity and compared them with established commercial methods along with visual assessment. Renal biopsy CD3 immunohistochemistry slides (n = 45), including renal allografts with various degrees of acute cellular rejection (ACR) were scanned for whole slide images (WSIs). Inflammation was quantitated in the WSIs using pathologist visual assessment, commercial algorithms (Aperio nuclear algorithm for CD3+ cells/mm 2 and Aperio positive pixel count algorithm), and customized open source algorithms developed in ImageJ with thresholding/positive pixel counting (custom CD3+%) and identification of pixels fulfilling "maxima" criteria for CD3 expression (custom CD3+ cells/mm 2 ). Based on visual inspections of "markup" images, CD3 quantitation algorithms produced adequate accuracy. Additionally, CD3 quantitation algorithms correlated between each other and also with visual assessment in a statistically significant manner (r = 0.44 to 0.94, p = 0.003 to < 0.0001). Methods for assessing inflammation suggested a progression through the tubulointerstitial ACR grades, with statistically different results in borderline versus other ACR types, in all but the custom methods. Assessment of CD3-stained slides using various open source image analysis algorithms presents salient correlations with established methods of CD3 quantitation. These analysis techniques are promising and highly customizable, providing a form of on-slide "flow cytometry" that can facilitate additional diagnostic accuracy in tissue-based assessments.
NASA Astrophysics Data System (ADS)
Sennappan, M.; Murali Krishna, P.; Hosamani, Amar A.; Hari Krishna, R.
2018-07-01
An environmental benign and efficient reaction was carried out via amine exchange and condensation reaction in water and methanol mixture (3:1) and absence of catalyst between 1-[3-(2-hydroxy benzylidene)amine)phenyl]ethanone and benzhydrazide yields methaniminium hydrazone Schiff base in high yield. The prepared ligand was structurally characterized by using single crystal XRD, elemental analysis and spectroscopy (UV-Vis, FT-IR, LC-MS and NMR) techniques. The crystal data indicates the ligand crystallizes in orthorhombic system with Pna21 space group. Further, the ligand was used in synthesis of mononuclear Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and Cd(II) complexes and were characterized by elemental analysis, magnetic moment and spectroscopy (UV-Vis, FT-IR and ESR) studies. The spectral data showed that ligand is coordinated to the metal ion through azomethine nitrogen and methaniminium nitrogen. The DNA binding absorption titrations reveals that, ligand, L and its metal complexes, 1-6 are avid binders to CT- DNA. The apparent binding constant values of compounds are in the order of 106 M-1. The nuclease activity of ligand, L and its metal complexes, 1-6 were investigated by gel electrophoresis method using pUC18 DNA. The photoluminescent properties of the methaniminium hydrazone ligand, L and its various metal complexes, 1-6 were investigated. The emission spectra of both ligand (L) and metal complexes (1-6) exhibits emission in the range of blue to red.
Kornobis, Karina; Ruud, Kenneth; Kozlowski, Pawel M
2013-02-07
The nature of electronically excited states of the super-reduced form of vitamin B(12) (i.e., cob(I)alamin or B(12s)), a ubiquitous B(12) intermediate, was investigated by performing quantum-chemical calculations within the time-dependent density functional theory (TD-DFT) framework and by establishing their correspondence to experimental data. Using response theory, the electronic absorption (Abs), circular dichroism (CD) and magnetic CD (MCD) spectra of cob(I)alamin were simulated and directly compared with experiment. Several issues have been taken into considerations while performing the TD-DFT calculations, such as strong dependence on the applied exchange-correlation (XC) functional or structural simplification imposed on the cob(I)alamin. In addition, the low-lying transitions were also validated by performing CASSCF/MC-XQDPT2 calculations. By comparing computational results with existing experimental data a new level of understanding of electronic excitations has been established at the molecular level. The present study extends and confirms conclusions reached for other cobalamins. In particular, the better performance of the BP86 functional, rather than hybrid-type, was observed in terms of the excitations associated with both Co d and corrin π localized transitions. In addition, the lowest energy band was associated with multiple metal-to-ligand charge transfer excitations as opposed to the commonly assumed view of a single π → π* transition followed by vibrational progression. Finally, the use of the full cob(I)alamin structure, instead of simplified molecular models, shed new light on the spectral analyses of cobalamin systems and revealed new challenges of this approach related to long-range charge transfer excitations involving side chains.
Giudice, Valentina; Feng, Xingmin; Lin, Zenghua; Hu, Wei; Zhang, Fanmao; Qiao, Wangmin; Ibanez, Maria Del Pilar Fernandez; Rios, Olga; Young, Neal S
2018-05-01
Oligoclonal expansion of CD8 + CD28 - lymphocytes has been considered indirect evidence for a pathogenic immune response in acquired aplastic anemia. A subset of CD8 + CD28 - cells with CD57 expression, termed effector memory cells, is expanded in several immune-mediated diseases and may have a role in immune surveillance. We hypothesized that effector memory CD8 + CD28 - CD57 + cells may drive aberrant oligoclonal expansion in aplastic anemia. We found CD8 + CD57 + cells frequently expanded in the blood of aplastic anemia patients, with oligoclonal characteristics by flow cytometric Vβ usage analysis: skewing in 1-5 Vβ families and frequencies of immunodominant clones ranging from 1.98% to 66.5%. Oligoclonal characteristics were also observed in total CD8 + cells from aplastic anemia patients with CD8 + CD57 + cell expansion by T-cell receptor deep sequencing, as well as the presence of 1-3 immunodominant clones. Oligoclonality was confirmed by T-cell receptor repertoire deep sequencing of enriched CD8 + CD57 + cells, which also showed decreased diversity compared to total CD4 + and CD8 + cell pools. From analysis of complementarity-determining region 3 sequences in the CD8 + cell pool, a total of 29 sequences were shared between patients and controls, but these sequences were highly expressed in aplastic anemia subjects and also present in their immunodominant clones. In summary, expansion of effector memory CD8 + T cells is frequent in aplastic anemia and mirrors Vβ oligoclonal expansion. Flow cytometric Vβ usage analysis combined with deep sequencing technologies allows high resolution characterization of the T-cell receptor repertoire, and might represent a useful tool in the diagnosis and periodic evaluation of aplastic anemia patients. (Registered at clinicaltrials.gov identifiers: 00001620, 01623167, 00001397, 00071045, 00081523, 00961064 ). Copyright © 2018 Ferrata Storti Foundation.
Song, Gwan Gyu; Lee, Young Ho
2015-01-01
The aim of this study was to explore whether polymorphisms of intercellular adhesion molecule-1 (ICAM-1) are associated with susceptibility to Crohn's disease (CD) and ulcerative colitis (UC). The authors conducted a meta-analysis on the associations between the polymorphisms K469E and G241R of ICAM-1 and susceptibility to CD and UC. A total of 8 studies with 801 patients with CD, 672 patients with UC, and 1,828 controls were included in the meta-analysis. The meta-analysis revealed no association between CD and the ICAM-1 469E allele among the subjects (OR = 1.175, 95% CI = 0.901-1.533, p = 0.233). However, stratification by ethnicity indicated an association between the ICAM-1 469E allele and CD in Europeans (OR = 1.425, 95% CI = 1.013-2.002, p = 0.042). Meta-analysis using the homozygosity also showed an association with CD in Europeans (OR = 2.054, 95% CI = 1.036-4.073, p = 0.039). The meta-analysis revealed no association between UC and the ICAM-1 K469E polymorphism. No association between CD or UC and the ICAM-1 G241R polymorphism was observed. This meta-analysis demonstrates that the ICAM-1 K469E polymorphism may be associated with susceptibility to CD in Europeans, but no association was found between ICAM-1 K469E and UC. In contrast, the G241R polymorphism was not found to be associated with susceptibility to either CD or UC.
Gaps analysis for CD metrology beyond the 22nm node
NASA Astrophysics Data System (ADS)
Bunday, Benjamin; Germer, Thomas A.; Vartanian, Victor; Cordes, Aaron; Cepler, Aron; Settens, Charles
2013-04-01
This paper will examine the future for critical dimension (CD) metrology. First, we will present the extensive list of applications for which CD metrology solutions are needed, showing commonalities and differences among the various applications. We will then report on the expected technical limits of the metrology solutions currently being investigated by SEMATECH and others in the industry to address the metrology challenges of future nodes, including conventional CD scanning electron microscopy (CD-SEM) and optical critical dimension (OCD) metrology and new potential solutions such as He-ion microscopy (HeIM, sometimes elsewhere referred to as HIM), CD atomic force microscopy (CD-AFM), CD small-angle x-ray scattering (CD-SAXS), high-voltage scanning electron microscopy (HV-SEM), and other types. A technical gap analysis matrix will then be demonstrated, showing the current state of understanding of the future of the CD metrology space.
Di Cagno, Raffaella; Rizzello, Carlo G; Gagliardi, Francesca; Ricciuti, Patrizia; Ndagijimana, Maurice; Francavilla, Ruggiero; Guerzoni, M Elisabetta; Crecchio, Carmine; Gobbetti, Marco; De Angelis, Maria
2009-06-01
This study aimed at investigating the fecal microbiotas of children with celiac disease (CD) before (U-CD) and after (T-CD) they were fed a gluten-free diet and of healthy children (HC). Brothers or sisters of T-CD were enrolled as HC. Each group consisted of seven children. PCR-denaturing gradient gel electrophoresis (DGGE) analysis with V3 universal primers revealed a unique profile for each fecal sample. PCR-DGGE analysis with group- or genus-specific 16S rRNA gene primers showed that the Lactobacillus community of U-CD changed significantly, while the diversity of the Lactobacillus community of T-CD was quite comparable to that of HC. Compared to HC, the ratio of cultivable lactic acid bacteria and Bifidobacterium to Bacteroides and enterobacteria was lower in T-CD and even lower in U-CD. The percentages of strains identified as lactobacilli differed as follows: HC (ca. 38%) > T-CD (ca. 17%) > U-CD (ca. 10%). Lactobacillus brevis, Lactobacillus rossiae, and Lactobacillus pentosus were identified only in fecal samples from T-CD and HC. Lactobacillus fermentum, Lactobacillus delbrueckii subsp. bulgaricus, and Lactobacillus gasseri were identified only in several fecal samples from HC. Compared to HC, the composition of Bifidobacterium species of T-CD varied, and it varied even more for U-CD. Forty-seven volatile organic compounds (VOCs) belonging to different chemical classes were identified using gas-chromatography mass spectrometry-solid-phase microextraction analysis. The median concentrations varied markedly for HC, T-CD, and U-CD. Overall, the r(2) values for VOC data for brothers and sisters were equal to or lower than those for unrelated HC and T-CD. This study shows the effect of CD pathology on the fecal microbiotas of children.
Spelt, Lidewij; Sasor, Agata; Ansari, Daniel; Hilmersson, Katarzyna Said; Andersson, Roland
2018-01-01
To assess the expression of cancer stem cell (CSC) markers CD44, CD133 and CD24 in colon cancer liver metastases and analyse their predictive value for overall survival (OS) and disease-free survival (DFS) after liver resection. Patients operated on for colon cancer liver metastases were included. CSC marker expression was determined through immunohistochemistry analysis. OS and DFS were compared between marker-positive and marker-negative patients. Multivariate analysis was performed to select predictive variables for OS and DFS. CD133-positive patients had a worse DFS than CD133-negative patients, with a median DFS of 12 and 25 months (p=0.051). Multivariate analysis selected CD133 expression as a significant predictor for DFS. CD44 and CD24 were not found to predict OS or DFS. CD133 expression in colonic liver metastases is a negative prognostic factor for DFS after liver resection. In the future, CD133 could be used as a biomarker for risk stratification, and possibly for developing novel targeted therapy. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Bernhard, Anka; Martinelli, Anne; Ackermann, Katharina; Saure, Daniel; Freitag, Christine M
2018-08-01
To summarize findings of previous studies on the prevalence of trauma and Posttraumatic Stress Disorder (PTSD) in Conduct Disorder (CD). We conducted a systematic review and meta-analysis following the PRISMA guidelines. EBSCOhost, PubMed, CDSR and ARIF databases were searched in October 2016, employing relevant keywords. 19 studies met inclusion criteria. Meta-analysis resulted in a lifetime PTSD prevalence of 11% (95% CI: 7-17%) in children and adolescents with CD, 14% (95% CI: 12-15%) in adults with pre-existing CD and 32% (95% CI: 25-40%) in juvenile offenders with CD. Higher lifetime PTSD prevalence was observed in individuals with than without CD, and in females compared to males with CD. Studies focusing on the association of trauma, PTSD and CD are still relatively rare. Possible comorbidity models are discussed considering psychological and biological risk factors in a comprehensive model. The high rate of PTSD in CD may be due to shared risk factors; furthermore, CD might increase the risk for comorbid PTSD due to CD inherent risk taking behavior. To study pathways of risk, especially longitudinal studies are necessary. Copyright © 2017 Elsevier Ltd. All rights reserved.
In-Depth Analysis of Citrulline-Specific CD4 T Cells in Rheumatoid Arthritis
2017-01-01
AWARD NUMBER: W81XWH-15-1-0003 TITLE: In-Depth Analysis of Citrulline-Specific CD4 T Cells in Rheumatoid Arthritis PRINCIPAL INVESTIGATOR...TITLE AND SUBTITLE In-Depth Analysis of Citrulline-Specific CD4 T Cells in Rheumatoid Arthritis 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0003...NOTES 14. ABSTRACT The goal of this project is to test the hypothesis that cit-specific CD4 T cells present in rheumatoid arthritis (RA) patients
In-Depth Analysis of Citrulline Specific CD4 T-Cells in Rheumatoid Arthritis
2017-01-01
AWARD NUMBER: W81XWH-15-1-0004 TITLE: In-Depth Analysis of Citrulline-Specific CD4 T-Cells in Rheumatoid Arthritis PRINCIPAL INVESTIGATOR...2016 4. TITLE AND SUBTITLE In-Depth Analysis of Citrulline-Specific CD4 T Cells in Rheumatoid Arthritis 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH...NOTES 14. ABSTRACT The goal of this project is to test the hypothesis that cit-specific CD4 T cells present in rheumatoid arthritis (RA) patients
Effects of chemo-mechanical polishing on CdZnTe X-ray and gamma-ray detectors
Egarievwe, Stephen E.; Hossain, Anwar; Okwechime, Ifechukwude O.; ...
2015-06-23
Here, mechanically polishing cadmium zinc telluride (CdZnTe) wafers for x-ray and gamma-ray detectors often is inadequate in removing surface defects caused by cutting them from the ingots. Fabrication-induced defects, such as surface roughness, dangling bonds, and nonstoichiometric surfaces, often are reduced through polishing and etching the surface. In our earlier studies of mechanical polishing with alumina powder, etching with hydrogen bromide in hydrogen peroxide solution, and chemomechanical polishing with bromine–methanol–ethylene glycol solution, we found that the chemomechanical polishing process produced the least surface leakage current. In this research, we focused on using two chemicals to chemomechanically polish CdZnTe wafers aftermore » mechanical polishing, viz. bromine–methanol–ethylene glycol (BME) solution, and hydrogen bromide (HBr) in a hydrogen peroxide and ethylene–glycol solution. We used x-ray photoelectron spectroscopy (XPS), current–voltage (I–V) measurements, and Am-241 spectral response measurements to characterize and compare the effects of each solution. The results show that the HBr-based solution produced lower leakage current than the BME solution. Results from using the same chemomechanical polishing solution on two samples confirmed that the surface treatment affects the measured bulk current (a combination of bulk and surface currents). XPS results indicate that the tellurium oxide to tellurium peak ratios for the mechanical polishing process were reduced significantly by chemomechanical polishing using the BME solution (78.9% for Te 3d 5/2O 2 and 76.7% for Te 3d 3/2O 2) compared with the HBr-based solution (27.6% for Te 3d 5/2O 2 and 35.8% for Te 3d 3/2O 2). Spectral response measurements showed that the 59.5-keV peak of Am-241 remained under the same channel number for all three CdZnTe samples. While the BME-based solution gave a better performance of 7.15% full-width at half-maximum (FWHM) compared with 7.59% FWHM for the HBr-based solution, the latter showed a smaller variation in performance of 0.39% FWHM over 7 days compared with 0.69% for the BME-based solution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delage, M; Cloutier, E; Lecavalier, M
2016-06-15
Purpose: This study intends to characterize the energy dependence of the effect of radiation damage on CdSe multi-shell (MS) (CdS/CdZnS/ZnS) and CdSe core/shell (CS)(ZnS) cQDs. It also aims to investigate irregularities resulting of pauses between subsequent irradiations. Methods: Radioluminescence (RL) measurements were performed with a CCD camera as dose was cumulated by the cQDs (up to 10 kGy), for beam energies 120 kVp, 220 kVp and 6 MV. Repeated expositions of 1999 MU were cumulated. Pauses between subsequent irradiations were varied from 2 to 50 minutes. cQDs photoluminescence (PL) and RL spectral stability was tracked by quantifying the position andmore » FWHM of the luminescence peak. Results: Both types of cQDs showed a clear energy dependence of the RL signal decrease between the kV and the MV beams. For 1.2 kGy of dose cumulated, MS cQDs had 92% of the initial signal left at 6 MV compared to 98% at 120 kVp. The same was observed for CS cQDs: 87% at 6 MV vs 94% at 120 kVp. MS cQDs were found to have a systematic (though small, ∼1%) RL intensity recovery for pauses of 15 minutes or more, while CS cQDs maintain a stable loss regardless of the pause duration. PL and RL spectral measurements revealed a good stability (< 1% variation of the peak position and FWHM) for both types of cQDs. Conclusion: In all, both MS and CS cQDs have a sufficient resistance to large doses of radiation for standard radiation therapy and imaging. Since this resistance is better for lower energy, the utilization of cQDs could be optimized for low energy applications (e.g. theragnostic applications for small animal studies and others). Finally, the ionizing radiation damage mechanisms for this new type of nano-scintillator still have to be identified properly.« less
The circular dichroism properties of phi W-14 DNA containing alpha-putrescinylthymine.
Spetter, S; Chen, C; Warren, R A; Hanlon, S
1985-03-08
The circular dichroism properties of phi W-14 DNA containing alpha-putrescinylthymine and its acetylated derivative have been examined in a number of aqueous solvents. Native phi W-14 DNA exhibits a B-type CD spectrum whose characteristics do not entirely conform to what would be expected for its GC content (51%). The conformationally sensitive positive band above 260 nm has a rotational strength greater than that normally found in prokaryotic DNAs of comparable GC content, such as Escherichia coli DNA. The rotational strength of this band in the spectrum of the heat-denatured form of phi W-14 DNA, however, is similar to that of heat denatured E. coli DNA. Abolition of the positive charge on the putrescine residues of native phi W-14 DNA by reaction with CH2O or by acetylation reduces the rotational strength to a level appropriate for its GC content. Increases in the electrolyte content of the solvent have the same effect, although the rotational strength of this band in phi W-14 DNA does not become comparable to that of E. coli DNA until 6-7 M LiCl. Titration to pH 10.6 in solvents of modest electrolyte content, however, fails to appreciably affect the CD spectral properties of either native phi W-14 DNA or the derivative in which half of the secondary and all of the primary amino groups have been acetylated. On the basis of these results we have concluded that the enhanced rotational strength of the positive band above 260 nm in the CD spectrum of phi W-14 DNA is due to a conformational difference caused by an ion-pair interaction of the positively charged primary amino groups of putrescine with the phosphate backbone. The CD spectral properties, however, reveal that these differences, averaged over the entire basepair population, appear to be relatively small. The average conformation, at least in dilute aqueous solutions, seems to be an unexceptional B variant with conformational properties which would be more appropriate for a DNA of higher CG content.
Immunophenotypic analysis of Waldenstrom's macroglobulinemia.
San Miguel, J F; Vidriales, M B; Ocio, E; Mateo, G; Sánchez-Guijo, F; Sánchez, M L; Escribano, L; Bárez, A; Moro, M J; Hernández, J; Aguilera, C; Cuello, R; García-Frade, J; López, R; Portero, J; Orfao, A
2003-04-01
Immunophenotyping has become an essential tool for diagnosis of hematological malignancies. By contrast, for diagnosis of Waldenstrom's macroglobulinemia (WM) immunophenotyping is used only occasionally. From 150 patients with a IgM monoclonal gammopathy we have selected 60 cases with (1) morphological lymphoplasmocytoid bone marrow (BM) infiltration (>20%); (2) IgM paraprotein (>10g/L); and (3) absence of features of other lymphoma types. Immunophenotypic analysis was based on the use of the triple or quadruple monoclonal antibody (MoAb) combinations. To increase the sensitivity of the analysis of antigen expression, selected CD19(+)CD20(+) B cells were targeted. We have also explored the antigenic characteristics of both the plasma cell (PC) and mast cell (MC) compartments present in the BM from 15 WM patients. Clonal WM lymphocytes were characterized by the constant expression of pan-B markers (CD19, CD20, CD22, CD24) together with sIg, predominantly kappa (5:1, kappa:lambda ratio). A high proportion of cases (75%) were positive for FMC7 and CD25, but in contrast to hairy cell leukemia (HCL), these lymphocytes were always negative for CD103 and CD11c. CD10 antigen was also absent in all WM patients and less than one fifth of patients were positive for CD5 and CD23, while CD27, CD45RA, and BCL-2 were present in most malignant cells. In two cases, the coexistence of two different clones of B lymphocytes was identified, and in eight additional cases, intraclonal phenotypic heterogeneity was observed. As far as PCs are concerned, in most patients (85%) the number of PCs was within the normal range (median, 0.36%). The antigenic profile of these PCs differed from that observed in normal and myelomatous PC (CD38(++)CD19(++/-)CD56(-)CD45(++)CD20(+)). In three cases, PCs showed aberrant expression for CD5, CD22, or FMC7. Finally, the number of mast cells was significantly higher (0.058 +/- 0.13) as compared to normal BM (0.019 +/- 0.02) (P <.01), although they were immunophenotypically normal (CD117(+)CD2(-)CD25(-)). Copyright 2003 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Xu, Changhua; Jia, Xiaoguang; Xu, Rong; Wang, Yang; Zhou, Qun; Sun, Suqin
2013-10-01
Herba Cistanche, an important Chinese herbal medicine, has common four species, Cistanche deserticola (CD), Cistanche tubulosa (CT), Cistanche salsa (CS) and Cistanche sinensis (CSN) which have been frequent mixed used. To clarify the sources of Herba Cistanches and ensure the clinical efficacy and safety, a method combing IR macro-fingerprinting with statistical pattern recognition was developed to analyze and discriminate the four species of Herba Cistanche. By comparing FT-IR, second derivative spectral fingerprints via group-peak matching, the similarity to CD and total saccharides (TS) followed an increasing sequence, CT < CSN < CS < CD, whereas that to total glycosides (TG) followed a decreasing order, CT > CSN > CS > CD. Characteristic fingerprints of their 2D-IR correlation spectra in 1750-1000 cm-1 have confirmed the above findings in a more intuitive way. In terms of sources for phenylethanoid glycosides (PhGs), CT can be an ideal alternative species. However, in terms of using them as a whole, more pharmacological study should be conducted due to the different ratios of their chemical constituents, which is also applicable to CSN and CS. Moreover, the four species (179 samples) has been objectively classified by SIMCA based on IR macro-fingerprints.
Associations between CD24 gene polymorphisms and inflammatory bowel disease: A meta-analysis.
Huang, Xiao-Li; Xu, Dong-Hua; Wang, Guo-Pin; Zhang, Shu; Yu, Cheng-Gong
2015-05-21
To evaluate the relationships between CD24 gene polymorphisms and the risk of inflammatory bowel disease (IBD), including ulcerative colitis (UC) and Crohn's disease (CD). The PubMed, Web of Science and Cochrane Library databases were searched (up to May 30, 2014). The search terms "CD24", "inflammatory bowel disease", "Crohn's disease", "Ulcerative colitis", "IBD", "CD" or "UC"; and "polymorphism", "mutation" or "variant" were used. Association studies were limited to the English language, but no limitations in terms of race, ethnicity or geographic area were employed. Stata SE12 software was used to calculate the pooled odds ratios (ORs) with 95% confidence intervals (CIs). P < 0.05 was considered statistically significant. The information was independently extracted from each eligible study by two investigators. Two common polymorphisms, C170T (rs8734) and TG1527del (rs3838646), in the CD24 gene were assessed. A total of three case-control studies including 2342 IBD patients and 1965 healthy controls were involved in this meta-analysis. The patients and controls were from Caucasian cohorts. The three articles included in this meta-analysis all conformed to Hardy-Weinberg equilibrium. This meta-analysis revealed that there were no significant associations between the two CD24 polymorphisms and the risk for IBD (all P > 0.05). However, in a disease subgroup analysis, we found that the CD24 C170T polymorphism was associated with an increased risk of UC in a dominant model (OR = 1.79, 95%CI: 1.15-2.77, P = 0.009) and an additive model (OR = 1.87, 95%CI: 1.19-2.93, P = 0.007), but this relationship was not present for CD. The CD24 TG1570del polymorphism was significantly associated with CD in the additive model (OR = 1.24, 95%CI: 1.01-1.52, P = 0.037). Our findings provide evidence that the CD24 C170T polymorphism might contribute to the susceptibility to UC, and the CD24 TG1527del polymorphism might be associated with the risk of CD.
NASA Astrophysics Data System (ADS)
Kislov, E. V.; Kulikov, A. A.; Kulikova, A. B.
1989-10-01
Samples of basit-ultrabasit rocks and NiCu ores of the Ioko-Dovyren and Chaya massifs were analysed by SRXFA and a chemical-spectral method. SRXFA perfectly satisfies the quantitative noble-metals analysis of ore-free rocks. Combination of SRXFA and chemical-spectral analysis has good prospects. After analysis of a great number of samples by SRXFA it is necessary to select samples which would show minimal and maximal results for the chemical-spectral method.
Spectral Properties and Dynamics of Gold Nanorods Revealed by EMCCD Based Spectral-Phasor Method
Chen, Hongtao; Digman, Michelle A.
2015-01-01
Gold nanorods (NRs) with tunable plasmon-resonant absorption in the near-infrared region have considerable advantages over organic fluorophores as imaging agents. However, the luminescence spectral properties of NRs have not been fully explored at the single particle level in bulk due to lack of proper analytic tools. Here we present a global spectral phasor analysis method which allows investigations of NRs' spectra at single particle level with their statistic behavior and spatial information during imaging. The wide phasor distribution obtained by the spectral phasor analysis indicates spectra of NRs are different from particle to particle. NRs with different spectra can be identified graphically in corresponding spatial images with high spectral resolution. Furthermore, spectral behaviors of NRs under different imaging conditions, e.g. different excitation powers and wavelengths, were carefully examined by our laser-scanning multiphoton microscope with spectral imaging capability. Our results prove that the spectral phasor method is an easy and efficient tool in hyper-spectral imaging analysis to unravel subtle changes of the emission spectrum. Moreover, we applied this method to study the spectral dynamics of NRs during direct optical trapping and by optothermal trapping. Interestingly, spectral shifts were observed in both trapping phenomena. PMID:25684346
NASA Astrophysics Data System (ADS)
Fang, Qing; Wang, Yirun; Hu, Taoying; Liu, Ying
2017-02-01
The interaction of minocyeline (MNC) with extracelluar protein (lysozyme, LYSO) or intracellular protein (bovine hemoglobin, BHb) was investigated using multi-spectral techniques and molecular docking in vitro. Fluorescence studies suggested that MNC quenched LYSO/BHb fluorescence in a static mode with binding constants of 2.01 and 0.26 × 104 L•mol-1 at 298 K, respectively. The LYZO-MNC system was more easily influenced by temperature (298 and 310 K) than the BHb-MNC system. The thermodynamic parameters demonstrated that hydrogen bonds and van der Waals forces played the major role in the binding process. Based on the Förster theory of nonradiative energy transfer, the binding distances between MNC and the inner tryptophan residues of LYSO and BHb were calculated to be 4.34 and 3.49 nm, respectively. Furthermore, circular dichroism spectra (CD), Fourier transforms infrared (FTIR), UV-vis, and three-dimensional fluorescence spectra results indicated the secondary structures of LYSO and BHb were partially destroyed by MNC with the α-helix percentage of LYZO-MNC increased (17.8-28.6%) while that of BHb-MNC was decreased (41.6-39.6%). UV-vis spectral results showed these binding interactions could cause conformational and some micro-environmental changes of LYSO and BHb. In accordance with the results of molecular docking, In LYZO-MNC system, MNC was mainly bound in the active site hinge region where Trp-62 and Trp-63 are located, and in MNC-BHb system, MNC was close to the subunit α 1 of BHb, molecular docking analysis supported the thermodynamic results well. The work contributes to clarify the mechanism of MNC with two proteins at molecular level.
NASA Astrophysics Data System (ADS)
Varghese, Beena; Suliman, FakhrEldin O.; Al-Hajri, Aalia; Al Bishri, Nahed Surur S.; Al-Rwashda, Nathir
2018-02-01
The inclusion complexes of sulfamethoxazole (SMX) with β-cyclodextrin (βCD) and (2-hydroxypropyl) β-cyclodextrin (HPβCD) were prepared. Fluorescence spectroscopy and electrospray mass spectrometry, ESI-MS, were used to investigate and characterize the inclusion complexation of SMX with cyclodextrins in solutions. Whereas in the solid state the complexes were characterized by Fourier transform infrared spectroscopy (FTIR), powder X-ray diffraction (PXRD) and Raman techniques. Enhanced twisted intramolecular charge transfer (TICT), emission as well as local excited (LE) bands were observed upon addition of HPβCD indicate that SMX enters deeper into the cyclodextrins cavity. The stoichiometries and association constants of these complexes have been determined by monitoring the fluorescence data. The effect of presence of ternary components like arginine and cysteine on the complexation efficiency of SMX with cyclodextrins was investigated. Molecular Dynamic simulations were also performed to shed an atomistic insight into the complexation mechanism. The results obtained showed that complexes of SMX with both cyclodextrins are stabilized in aqueous media by strong hydrogen bonding interactions.
NASA Astrophysics Data System (ADS)
Gu, Hongan; Dai, Ye; Wang, Haodong; Yan, Xiaona; Ma, Guohong
2017-12-01
In this paper, a femtosecond laser line-scanning irradiation was used to induce the periodic surface microstructure on HgCdTe crystal. Low spatial frequency laser induced periodic surface structures of 650-770 nm and high spatial frequency laser induced periodic surface structures of 152-246 nm were respectively found with different scanning speeds. The evolution process from low spatial frequency laser induced periodic surface structures to high spatial frequency laser induced periodic surface structures is characterized by scanning electron microscope. Their spatial periods deduced by using a two-dimensional Fourier transformation partly agree with the predictions of the Sipe-Drude theory. Confocal micro-Raman spectral show that the atomic arrangement of induced low spatial frequency laser-induced structures are basically consistent with the crystal in the central area of laser-scanning line, however a new peak at 164 cm-1 for the CdTe-like mode becomes evident due to the Hg vaporization when strong laser ablation happens. The obtained surface periodic ripples may have applications in fabricating advanced infrared detector.
da Costa, M H; Chaimovich, H
1997-09-01
Limited proteolysis of fatty acid-free bovine serum albumin by pepsin yields several well characterized peptides, one of which (P9, M(r) 9,000), induces fusion of small unilamellar vesicles (SUV) of phosphatidylcholine at pH 3.6. Circular dichroism (CD) of P9 solutions confirmed that the peptide undergoes a reversible transition between pH 7 and pH 3.6. The spectral changes observed with CD suggest that in the low pH conformation there is a decrease in the alpha-helical contents and an exposure of hydrophobic residues. CD and differential ultraviolet spectroscopy demonstrated that P9 binds to micelles of hexadecylphosphorylcholine and the binding produces changes in the tertiary structure of the peptide. Reduction and carboxymethylation of the two disulfide bridges of P9 produced loss of the ability to induce fusion of SUV, although the reduced peptide binds to vesicles, induces loss of entrapped marker and produces vesicle disruption. In the active form P9 exposes hydrophobic groups, one amphiphilic alpha-helix and requires the integrity of the disulfide bridge-stabilized tertiary structure.
Integrated receiver for heterodyne detection dedicated to space applications
NASA Astrophysics Data System (ADS)
Fleury, Joel; Girard, Olivier; Royer, Michel; Bidaud, Michel
1998-10-01
This paper is devoted to the presentation of an Integrator Dewar Cooling Assembly dedicated to high frequency space applications. SAGEM SA has been a manufacturer of IR InSb and HgCdTe detectors for a long time. These detectors cover a large spectral range. The capability to use HgCdTe photovoltaic detectors for heterodyne applications at 10.6 micrometers has been demonstrated in the frame of ESA and CNES contracts. SAGEM SA has recently developed a new concept of heterodyne receiver, totally integrated, operating at variable temperatures down to 77K, using HgCdTe or InSb photovoltaic detectors. This receiver is an innovative product due to its small volume, its low weight and its low electrical consumption. The miniaturization of this product the latter to be used in space applications, specially for the earth observation missions. The performance of such a receiver with respect of the electrical bandwidth is presented in order to compare it with a receiver for terrestrial or airborne applications based on the use of a laboratory HF dewar.
Sousa, A E; Victorino, R M M
1998-01-01
In this study we investigated at single-cell level by flow cytometry the potential of T cell cytokine production in asymptomatic HIV-1-infected subjects with > 200 CD4 counts and possible correlation with T helper cell depletion and viral load. Mitogen-stimulated peripheral blood mononuclear cells from 32 HIV-1+ patients and 16 healthy subjects were intracytoplasmically stained for IL-2, interferon-gamma (IFN-γ), IL-4 or IL-10, and the frequency of cytokine-producing cells was assessed in total T cells, CD4, CD8 and CD45RO subsets as well as in CD69+CD3+ gated lymphocytes. HIV-1+ patients, irrespective of their degree of CD4 depletion, exhibited a major increase in IFN-γ+ CD8 T cells, largely due to CD28− cells, as well as a decrease in the capacity of CD8 T cells to produce IL-2. Patients with > 500 CD4 counts showed a diminished frequency of IL-4 expression in CD4 T cells and a negative correlation was found between this parameter and the ex vivo CD4 counts in the 32 patients. Analysis of patients stratified according to viral load revealed a significantly higher proportion of IL-2-producing CD4 cells in the group with < 5000 RNA copies/ml. In short, using single-cell analysis and an antigen-presenting cell-independent stimulus, we have not been able to find any significant cytokine imbalances in the CD4 subset, suggesting that the well described T helper defects are not due to intrinsic alterations in the potential of CD4 T cells to produce cytokines. On the other hand, the major disturbances in the CD8 T lymphocytes agree with the marked activation and possible replicative senescence of CD8 T cells and emphasize the role of this subset in HIV immunopathogenesis. PMID:9649194
Tošić, Snežana B; Mitić, Snežana S; Velimirović, Dragan S; Stojanović, Gordana S; Pavlović, Aleksandra N; Pecev-Marinković, Emilija T
2015-08-30
An inductively coupled plasma-optical emission spectrometry method for the speedy simultaneous detection of 19 elements in edible nuts (walnuts: Juglans nigra; almonds: Prunus dulcis; hazelnuts: Corylus avellana; Brazil nuts: Bertholletia excelsa; cashews: Anacardium occidentalle; pistachios: Pistacia vera; and peanuts: Arachis hypogaea) available on the Serbian markets, was optimized and validated through the selection of instrumental parameters and analytical lines free from spectral interference and with the lowest matrix effects. The analysed macro-elements were present in the following descending order: Na > Mg > Ca > K. Of all the trace elements, the tested samples showed the highest content of Fe. The micro-element Se was detected in all the samples of nuts. The toxic elements As, Cd and Pb were either not detected or the contents were below the limit of detection. One-way analysis of variance, Student's t-test, Tukey's HSD post hoc test and hierarchical agglomerative cluster analysis were applied in the statistical analysis of the results. Based on the detected content of analysed elements it can be concluded that nuts may be a good additional source of minerals as micronutrients. © 2014 Society of Chemical Industry.
Ju-Kun, Song; Yuan, Dong-Bo; Rao, Hao-Fu; Chen, Tian-Fei; Luan, Bo-Shi; Xu, Xiao-Ming; Jiang, Fu-Neng; Zhong, Wei-De; Zhu, Jian-Guo
2016-02-01
Several observational studies on the association between Cd exposure and risk of prostate cancer have yielded inconsistent results. To address this issue, we conducted a meta-analysis to evaluate the correlation between Cd exposure and risk of prostate cancer.Relevant studies in PubMed and Embase databases were retrieved until October 2015. We compared the highest and lowest meta-analyses to quantitatively evaluate the relationship between Cd exposure and risk of prostate cancer. Summary estimates were obtained using a random-effects model.In the general population, high Cd exposure was not associated with increased prostate cancer (OR 1.21; 95% CI 0.91-1.64), whereas the combined standardized mortality ratio of the association between Cd exposure and risk of prostate cancer was 1.66 (95% CI 1.10-2.50) in populations exposed to occupational Cd. In addition, high D-Cd intake (OR 1.07; 95% CI 0.96-1.20) and U-Cd concentration (OR 0.86; 95% CI 0.48-1.55) among the general population was not related to the increased risk of prostate cancer. In the dose analysis, the summary relative risk was 1.07 (95% CI 0.73-1.57) for each 0.5 μg/g creatinine increase in U-Cd and 1.02 (95% CI 0.99-1.06) for each 10 μg/day increase of dietary Cd intake. However, compared with nonoccupational exposure, high occupational Cd exposure may be associated with the increased risk of prostate cancer.This meta-analysis suggests high Cd exposure as a risk factor for prostate cancer in occupational rather than nonoccupational populations. However, these results should be carefully interpreted because of the significant heterogeneity among studies. Additional large-scale and high-quality prospective studies are needed to confirm the association between Cd exposure and risk of prostate cancer.
Crucian, Brian; Sams, Clarence
2015-01-01
Alterations in immune function have been documented during or post-spaceflight and in ground based models of microgravity. Identification of immune parameters that are dysregulated during spaceflight is an important step in mitigating crew health risks during deep space missions. The in vitro analysis of leukocyte activity post-spaceflight in both human and animal species is primarily focused on lymphocytic function. This report completes a broader spectrum analysis of mouse lymphocyte and monocyte changes post 13 days orbital flight (mission STS-135). Analysis includes an examination in surface markers for cell activation, and antigen presentation and co-stimulatory molecules. Cytokine production was measured after stimulation with T-cell mitogen or TLR-2, TLR-4, or TLR-5 agonists. Splenocyte surface marker analysis immediate post-spaceflight and after in vitro culture demonstrated unique changes in phenotypic populations between the flight mice and matched treatment ground controls. Post-spaceflight splenocytes (flight splenocytes) had lower expression intensity of CD4+CD25+ and CD8+CD25+ cells, lower percentage of CD11c+MHC II+ cells, and higher percentage of CD11c+MHC I+ populations compared to ground controls. The flight splenocytes demonstrated an increase in phagocytic activity. Stimulation with ConA led to decrease in CD4+ population but increased CD4+CD25+ cells compared to ground controls. Culturing with TLR agonists led to a decrease in CD11c+ population in splenocytes isolated from flight mice compared to ground controls. Consequently, flight splenocytes with or without TLR-agonist stimulation showed a decrease in CD11c+MHC I+, CD11c+MHC II+, and CD11c+CD86+ cells compared to ground controls. Production of IFN-γ was decreased and IL-2 was increased from ConA stimulated flight splenocytes. This study demonstrated that expression of surface molecules can be affected by conditions of spaceflight and impaired responsiveness persists under culture conditions in vitro. PMID:25970640
Panayotou, G; Bax, B; Gout, I; Federwisch, M; Wroblowski, B; Dhand, R; Fry, M J; Blundell, T L; Wollmer, A; Waterfield, M D
1992-01-01
Circular dichroism and fluorescence spectroscopy were used to investigate the structure of the p85 alpha subunit of the PI 3-kinase, a closely related p85 beta protein, and a recombinant SH2 domain-containing fragment of p85 alpha. Significant spectral changes, indicative of a conformational change, were observed on formation of a complex with a 17 residue peptide containing a phosphorylated tyrosine residue. The sequence of this peptide is identical to the sequence surrounding Tyr751 in the kinase-insert region of the platelet-derived growth factor beta-receptor (beta PDGFR). The rotational correlation times measured by fluorescence anisotropy decay indicated that phosphopeptide binding changed the shape of the SH2 domain-containing fragment. The CD and fluorescence spectroscopy data support the secondary structure prediction based on sequence analysis and provide evidence for flexible linker regions between the various domains of the p85 proteins. The significance of these results for SH2 domain-containing proteins is discussed. Images PMID:1330535
Patnaik, Bharat Bhusan; Kang, Seong Min; Seo, Gi Won; Lee, Hyo Jeong; Patnaik, Hongray Howrelia; Jo, Yong Hun; Tindwa, Hamisi; Lee, Yong Seok; Lee, Bok Luel; Kim, Nam Jung; Bang, In Seok; Han, Yeon Soo
2013-10-15
CD63, a member of the tetraspanin membrane protein family, plays a pivotal role in cell growth, motility, signal transduction, host-pathogen interactions and cancer. In this work, the cDNA encoding CD63 homologue (TmCD63) was cloned from larvae of a coleopteran beetle, Tenebrio molitor. The cDNA is comprised of an open reading frame of 705 bp, encoding putative protein of 235 amino acid residues. In silico analysis shows that the protein has four putative transmembrane domains and one large extracellular loop. The characteristic "Cys-Cys-Gly" motif and "Cys188" residues are highly conserved in the large extracellular loop. Phylogenetic analysis of TmCD63 revealed that they belong to the insect cluster with 50%-56% identity. Analysis of spatial expression patterns demonstrated that TmCD63 mRNA is mainly expressed in gut and Malphigian tubules of larvae and the testis of the adult. Developmental expression patterns of CD63 mRNA showed that TmCD63 transcripts are detected in late larval, pupal and adult stages. Interestingly, TmCD63 transcripts are upregulated to the maximum level of 4.5 fold, in response to DAP-type peptidoglycan during the first 6 h, although other immune elicitors also caused significant increase to the transcript level at later time-points. These results suggest that CD63 might contribute to T. molitor immune response against various microbial pathogens.
Patnaik, Bharat Bhusan; Kang, Seong Min; Seo, Gi Won; Lee, Hyo Jeong; Patnaik, Hongray Howrelia; Jo, Yong Hun; Tindwa, Hamisi; Lee, Yong Seok; Lee, Bok Luel; Kim, Nam Jung; Bang, In Seok; Han, Yeon Soo
2013-01-01
CD63, a member of the tetraspanin membrane protein family, plays a pivotal role in cell growth, motility, signal transduction, host-pathogen interactions and cancer. In this work, the cDNA encoding CD63 homologue (TmCD63) was cloned from larvae of a coleopteran beetle, Tenebrio molitor. The cDNA is comprised of an open reading frame of 705 bp, encoding putative protein of 235 amino acid residues. In silico analysis shows that the protein has four putative transmembrane domains and one large extracellular loop. The characteristic “Cys-Cys-Gly” motif and “Cys188” residues are highly conserved in the large extracellular loop. Phylogenetic analysis of TmCD63 revealed that they belong to the insect cluster with 50%–56% identity. Analysis of spatial expression patterns demonstrated that TmCD63 mRNA is mainly expressed in gut and Malphigian tubules of larvae and the testis of the adult. Developmental expression patterns of CD63 mRNA showed that TmCD63 transcripts are detected in late larval, pupal and adult stages. Interestingly, TmCD63 transcripts are upregulated to the maximum level of 4.5 fold, in response to DAP-type peptidoglycan during the first 6 h, although other immune elicitors also caused significant increase to the transcript level at later time-points. These results suggest that CD63 might contribute to T. molitor immune response against various microbial pathogens. PMID:24132157
Sea urchin like shaped cdse nanoparticles grown in aqueous solutions via electron beam irradiation.
Singh, Shalini; Guleria, Apurav; Rath, M C; Singh, A K; Adhikari, S; Sarkar, S K
2013-08-01
Cadmium selenide (CdSe) nanoparticles have been grown from an aqueous solutions containing equimolar ammoniated cadmium sulphate and sodium selenosulphate as precursors in presence of citric acid as a capping agent, via electron beam irradiation. The radiolytic processes occurring in the medium result in the formation of CdSe nanoparticles through the reactions mediated by hydrated electrons (e(aq)-). The dynamics of the formation of these nanoparticles was investigated by pulse radiolysis studies. The size of the primary nanoparticles as estimated from the absorption spectra recorded immediately was less than 3 nm. These nanoparticles exhibited strong excitonic absorption pattern and broad photoluminescence at room temperature, which has been attributed to the presence of surface states/defects. This has been confirmed by Raman spectral studies, where CdSe nanoparticles exhibited characteristic surface phonon modes at around 250 cm(-1). The photoluminescence lifetime decay measurements further supported the existence of surface defects on the as-grown CdSe nanoparticles. These nanoparticles were found to exist in the agglomerated form of sea urchin like shapes of uniform size of about 500 nm as revealed from TEM and SEM images. These sea urchin like shaped CdSe nanoparticles grown in this route were found to be very stable under the ambient conditions. We infer that citric acid influences the growth as well as stability of these nanoparticles. It is expected that these nanomaterials could find potential applications in the field of sensors, catalysis and photovoltaics.
NASA Astrophysics Data System (ADS)
Li, Rui; Zhang, Hua; Liu, Xiaohua; Zhao, Shutao; Liu, Yadong; Yan, Bing
2018-01-01
Cadmium iodide (CdI), which is a candidate for laser material in chemical lasing, has attracted considerable scientific interest. While the complete picture for electronic structure of CdI is still unclear, particularly for the interactions of excited states. In this paper, high-level configuration interaction method is applied to compute the low-lying electronic states of the lowest two dissociation limits (Cd(1S) + I(2P) and Cd(3P) + I(2P)). To ensure the accuracy, the Davidson correction, core-valence electronic correlations and spin-orbit coupling effects are also taken into account. The potential energy curves of the 14 Λ-S states and 30 Ω states obtained from those Λ-S states are calculated. On the basis of the computed potential energy curves, the spectroscopic constants of bound and quasibound states are determined, most of which have not been reported in existing studies. The calculated values of spin-orbit coupling matrix elements demonstrate that the B2Σ+1/2 state imposes a strong perturbation on ν‧> 0 vibrational level of C2Π1/2, which can explain the weak spectral intensity of C2Π1/2-X2Σ+1/2 observed in previous experiment. The transition dipole moments as well as the lifetimes are evaluated to predict the transition properties of B2Σ+1/2, C2Π1/2 and 22Π3/2 states.
Synthesis and spectroscopic study of CdS nanoparticles using hydrothermal method
NASA Astrophysics Data System (ADS)
AL-Mamoori, Mohammed H. K.; Mahdi, Dunia K.; Al-Shrefi, Saif M.
2018-05-01
In this work, cadmium sulfide nanoparticles (powder) with diameter 50.8 nm was prepared using hydrothermal method. The structural and optical properties of CdS nanoparticles was studied by X-ray diffraction, FESEM, EDS, FTIR, UV-Diffuse Reflectance spectroscopy and Photoluminance spectrum. X-ray diffraction reveal the formation the purity of prepared phase of CdS particles with hexagonal wurtzite structure with particle size 31.8nm by using sheerer equation. The energy dispersion scattering (EDS) examination explains that the sample is composed of a large amount of Cd and S which are exactly CdS nanoparticles and there is a very small trace of (Zn) and (O) element observed because of there is a small pollutions in the measurement place of samples. FESEM shows the spherical shape of nanoparticles with around 50.8 nm diameter. The optical absorption spectral study identified the red shift of the sample in comparison to bulk ZnO in three dimensions. Photoluminance spectrum (PL) at room temperature showed that there are two luminescence peaks at 433.14 nm and 518.21nm. Samples demonstrate a sharp emission band at around 433.18 nm, which is attributed to the typical exciton luminescence. The broad band at 518.21nm which were attributed to the trapped luminescence. The green emission band at 518.21 nm was associated with the emission due to electronic transition from the conduction band to an accepter level due to interstitial sulphur ion.
Study of binary and ternary organic hybrid CdSe quantum dot photodetector
NASA Astrophysics Data System (ADS)
Ramar, M.; Kajal, S.; Pal, Prabir; Srivastava, R.; Suman, C. K.
2015-09-01
The hybrid binary and ternary photodetectors (PDs) were fabricated from P3HT-PC71BM with CdSe quantum dot (QD) materials. The absorption spectra of P3HT:PC71BM (named as B1), P3HT:CdSe (B2) and P3HT:CdSe:PC71BM (T) active blended material were analyzed in the wavelength range from 350 to 800 nm. The current density-voltage characteristics of the device were measured in dark and under illumination for study of detector detectivities and the contact with electrode. The ratio at -0.5 V for PDs B1, B2 and T is 1.1 × 102, 1.9 × 102 and 1.8 × 103, respectively. The values of detectivity for B1, B2 and T are 1 × 1010, 2 × 1010 and 7 × 1011 Jones, respectively. The for PD T is ten times in comparison with B1 and B2 PDs. The linear dynamic range (LDR) value for ternary device is more than double to both binary PDs. The absorption by CdSe QD increases the photon efficiency in the ternary detector, and at the same time the ternary detectors have high detectivity in broad spectral range. The responsivity of current to the light intensity exponent θ for detector B1, B2 and T is ~0.55, 0.55 and 0.62, respectively, which represents a complex process of electron hole generation, recombination and trapping within active material.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaiser, Uwe; Jimenez de Aberasturi, Dorleta; Vázquez-González, Margarita
2015-01-14
Semiconductor quantum dots functionalized with organic dye molecules are important tools for biological sensor applications. Energy transfer between the quantum dot and the attached dyes can be utilized for sensing. Though important, the determination of the real number of dye molecules attached per quantum dot is rather difficult. In this work, a method will be presented to determine the number of ATTO-590 dye molecules attached to CdSe/ZnS quantum dots based on time resolved spectral analysis. The energy transfer from the excited quantum dot to the attached ATTO-590 dye leads to a reduced lifetime of the quantum dot's excitons. The highermore » the concentration of dye molecules, the shorter the excitonic lifetime becomes. However, the number of dye molecules attached per quantum dot will vary. Therefore, for correctly explaining the decay of the luminescence upon photoexcitation of the quantum dot, it is necessary to take into account the distribution of the number of dyes attached per quantum dot. A Poisson distribution of the ATTO-590 dye molecules not only leads to excellent agreement between experimental and theoretical decay curves but also additionally yields the average number of dye molecules attached per quantum dot. In this way, the number of dyes per quantum dot can be conveniently determined.« less
Saxena, Rajshree
2015-01-01
The ability to predict protein function from structure is becoming increasingly important; hence, elucidation and determination of protein structure become the major steps in proteomics. The present study was undertaken for identification of metalloprotease produced by Bacillus cereus B80 and recognition of characteristics that can be industrially exploited. The enzyme was purified in three steps combining precipitation and chromatographic methods resulting in 33.5% recovery with 13.1-fold purification of enzyme which was detected as a single band with a molecular mass of 26 kDa approximately in SDS-PAGE and zymogram. The MALDI-TOF MS showed that the enzyme exhibited 70–93% similarity with zinc metalloproteases from various strains Bacillus sp. specifically from Bacillus cereus group. The sequence alignment revealed the presence of zinc-binding region VVVHEMCHMV in the most conserved C terminus region. Secondary structure of the enzyme was obtained by CD spectra and I-TASSER. The enzyme kinetics revealed a Michaelis constant (K m) of 0.140 μmol/ml and V max of 2.11 μmol/min. The application studies showed that the enzyme was able to hydrolyze various proteins with highest affinity towards casein followed by BSA and gelatin. The enzyme exhibited strong fibrinolytic, collagenolytic, and gelatinolytic properties and stability in various organic solvents. PMID:25802851
Spectroscopic studies of the interaction between pirimicarb and calf thymus DNA.
Zhang, Guowen; Hu, Xing; Pan, Junhui
2011-02-01
The interaction between pirimicarb and calf thymus DNA in physiological buffer (pH 7.4) was investigated with the use of Neutral Red (NR) dye as a spectral probe by UV-vis absorption, fluorescence and circular dichroism (CD) spectroscopy, as well as viscosity measurements and DNA melting techniques. The results revealed that an intercalation binding should be the interaction mode of pirimicarb to DNA. CD spectra indicated that pirimicarb induced conformational changes of DNA. The binding constants of pirimicarb with DNA were obtained by the fluorescence quenching method. The thermodynamic parameters, enthalpy change (ΔHθ) and entropy change (ΔSθ) were calculated to be -52.13±2.04 kJ mol(-1) and -108.8±6.72 J mol(-1) K(-1) according to the van't Hoff equation, which suggested that hydrogen bonds and van der Waals forces might play a major role in the binding of pirimicarb to DNA. Further, the alternative least squares (ALS) method was applied to resolve a complex two-way array of the absorption spectra data, which provided simultaneously the concentration information for the three reaction components, pirimicarb, NR and DNA-NR. This ALS analysis indicated that the intercalation of pirimicarb into the DNA by substituting for NR in the DNA-NR complex. Copyright © 2010 Elsevier B.V. All rights reserved.
Khajeh, Masoumeh Ashrafi; Dehghan, Gholamreza; Dastmalchi, Siavoush; Shaghaghi, Masoomeh; Iranshahi, Mehrdad
2018-03-05
DNA is a major target for a number of anticancer substances. Interaction studies between small molecules and DNA are essential for rational drug designing to influence main biological processes and also introducing new probes for the assay of DNA. Tschimgine (TMG) is a monoterpene derivative with anticancer properties. In the present study we tried to elucidate the interaction of TMG with calf thymus DNA (CT-DNA) using different spectroscopic methods. UV-visible absorption spectrophotometry, fluorescence and circular dichroism (CD) spectroscopies as well as molecular docking study revealed formation of complex between TMG and CT-DNA. Binding constant (K b ) between TMG and DNA was 2.27×10 4 M -1 , that is comparable to groove binding agents. The fluorescence spectroscopic data revealed that the quenching mechanism of fluorescence of TMG by CT-DNA is static quenching. Thermodynamic parameters (ΔH<0 and ΔS<0) at different temperatures indicated that van der Waals forces and hydrogen bonds were involved in the binding process of TMG with CT-DNA. Competitive binding assay with methylene blue (MB) and Hoechst 33258 using fluorescence spectroscopy displayed that TMG possibly binds to the minor groove of CT-DNA. These observations were further confirmed by CD spectral analysis, viscosity measurements and molecular docking. Copyright © 2017 Elsevier B.V. All rights reserved.
Synthesis of Colloidal Nanocrystal Heterostructures for High-Efficiency Light Emission
NASA Astrophysics Data System (ADS)
Lu, Yifei
Group II-VI semiconductor nanocrystals, particularly those based on ZnCdS(Se), can be synthesized using well established chemical colloidal processes, and have been a subject of extensive research over the past decade. Their optical properties can be easily tuned through size and composition variations, making them very attractive for many optoelectronic applications including light-emitting diodes (LEDs) and solar cells. Incorporation of diverse internal heterostructures provides an additional means for tuning the optical and electronic properties of conventional ZnCdS(Se) nanocrystals. Extensive bandgap and strain engineering may be applied to the resultant nanocrystal heterostructures to achieve desirable properties and enhanced performance. Despite the high scientific and practical interests of this unique class of nanomaterials, limited efforts have been made to explore their synthesis and potential device applications. This thesis focuses on the synthesis, engineering, characterization, and device demonstration of two types of CdSe-based nanocrystal heterostructures: core/multishell quantum dots (QDs) and QD quantum wells (QDQWs). Their optical properties have been tuned by bandgap and strain engineering to achieve efficient photoluminescence (PL) and electroluminescence (EL).Firstly, yellow light-emitting CdSe QDs with a strain-compensated ZnS/ZnCdS bilayer shell were synthesized using the successive ion layer adsorption and reaction technique and the effects of the shell on the luminescent properties were investigated. The core/shell/shell QDs enjoyed the benefits of excellent exciton confinement by the ZnS intermediate shell and strain compensation by the ZnCdS outer shell, and exhibited 40% stronger PL and a smaller peak redshift upon shell growth compared to conventional CdSe/ZnCdS/ZnS core/shell/shell QDs with an intermediate lattice adaptor. CdSe/ZnS/ZnCdS QD-LEDs had a luminance of 558 cd/m2 at 20 mA/cm 2, 28% higher than that of CdSe/ZnCdS/ZnS QD-LEDs. Secondly, CdS/CdSe/ZnS QDQWs were synthesized and their luminescence was tuned in an effort to realize efficient blue light emission from CdSe nanocrystals. CdSe QWs with a well width of 1.05 nm emitted at 467 nm with a spectral full-width-at-half-maximum of ~30 nm. With a 3-monolayer ZnS cladding layer which also acts as a passivating and strain-compensating layer, the QDQWs acquired a ~35% PL quantum yield (QY). Blue and green EL was obtained from QDQW-LEDs with 3-4.5 monolayers (MLs) QWs. It was found that as the well width and peak wavelength decreased, the overall EL was increasingly dominated by defect state emission, suggesting the device performance is mainly limited by poor charge injection into the QDQWs.
Interaction between Diethyldithiocarbamate and Cu(II) on Gold in Non-Cyanide Wastewater
Ly, Nguyễn Hoàng; Nguyen, Thanh Danh; Zoh, Kyung-Duk; Joo, Sang-Woo
2017-01-01
A surface-enhanced Raman scattering (SERS) detection method for environmental copper ions (Cu2+) was developed according to the vibrational spectral change of diethyldithiocarbamate (DDTC) on gold nanoparticles (AuNPs). The ultraviolet-visible (UV-Vis) absorption spectra indicated that DDTC formed a complex with Cu2+, showing a prominent peak at ~450 nm. We found Raman spectral changes in DDTC from ~1490 cm−1 to ~1504 cm−1 on AuNPs at a high concentration of Cu2+ above 1 μM. The other ions of Zn2+, Pb2+, Ni2+, NH4+, Mn2+, Mg2+, K+, Hg2+, Fe2+, Fe3+, Cr3+, Co2+, Cd2+, and Ca2+ did not produce such spectral changes, even after they reacted with DDTC. The electroplating industrial wastewater samples were tested under the interference of highly concentrated ions of Fe3+, Ni2+, and Zn2+. The Raman spectroscopy-based quantification of Cu2+ ions was able to be achieved for the wastewater after treatment with alkaline chlorination, whereas the cyanide-containing water did not show any spectral changes, due to the complexation of the cyanide with the Cu2+ ions. A micromolar range detection limit of Cu2+ ions could be achieved by analyzing the Raman spectra of DDTC in the cyanide-removed water. PMID:29140287
Interaction between Diethyldithiocarbamate and Cu(II) on Gold in Non-Cyanide Wastewater.
Ly, Nguyễn Hoàng; Nguyen, Thanh Danh; Zoh, Kyung-Duk; Joo, Sang-Woo
2017-11-15
A surface-enhanced Raman scattering (SERS) detection method for environmental copper ions (Cu 2+ ) was developed according to the vibrational spectral change of diethyldithiocarbamate (DDTC) on gold nanoparticles (AuNPs). The ultraviolet-visible (UV-Vis) absorption spectra indicated that DDTC formed a complex with Cu 2+ , showing a prominent peak at ~450 nm. We found Raman spectral changes in DDTC from ~1490 cm -1 to ~1504 cm -1 on AuNPs at a high concentration of Cu 2+ above 1 μM. The other ions of Zn 2+ , Pb 2+ , Ni 2+ , NH₄⁺, Mn 2+ , Mg 2+ , K⁺, Hg 2+ , Fe 2+ , Fe 3+ , Cr 3+ , Co 2+ , Cd 2+ , and Ca 2+ did not produce such spectral changes, even after they reacted with DDTC. The electroplating industrial wastewater samples were tested under the interference of highly concentrated ions of Fe 3+ , Ni 2+ , and Zn 2+ . The Raman spectroscopy-based quantification of Cu 2+ ions was able to be achieved for the wastewater after treatment with alkaline chlorination, whereas the cyanide-containing water did not show any spectral changes, due to the complexation of the cyanide with the Cu 2+ ions. A micromolar range detection limit of Cu 2+ ions could be achieved by analyzing the Raman spectra of DDTC in the cyanide-removed water.
Cloud Top Scanning radiometer (CTS)
NASA Technical Reports Server (NTRS)
1978-01-01
A scanning radiometer to be used for measuring cloud radiances in each of three spectral regions is described. Significant features incorporated in the Cloud Top Scanner design are: (1) flexibility and growth potential through use of easily replaceable modular detectors and filters; (2) full aperture, multilevel inflight calibration; (3) inherent channel registration through employment of a single shared field stop; and (4) radiometric sensitivity margin in a compact optical design through use of Honeywell developed (Hg,Cd)Te detectors and preamplifiers.
Sensor Modelling for the ’Cyclops’ Focal Plane Detector Array Based Technology Demonstrator
1992-12-01
Detector Array IFOV Instantaneous field of view IRFPDA Infrared Focal Plane Detector Array LWIR Long-Wave Infrared 0 MCT Mercury Cadmium Telluride MTF...scale focal plane detector array (FPDA). The sensor system operates in the long-wave infrared ( LWIR ) spectral region. The detector array consists of...charge transfer inefficiencies in the readout circuitry. The performance of the HgCdTe FPDA based sensor is limited by the nonuniformity of the
Imaging Sensor Development for Scattering Atmospheres.
1983-03-01
subtracted out- put from a CCD imaging detector for a single frame can be written as A _ S (2-22) V B + B{ shot noise thermal noise , dark current shot ...addition, the spectral re- sponses of current devices are limited to the visible region and their sensitivities are not very high. Solid state detectors ...are generally much more sensitive than spatial light modulators, and some (e.g., HgCdTe detectors ) can re- spond up to the 10 um region. Several
Zhang, Le-Le; Zhang, Zi-Ning; Wu, Xian; Jiang, Yong-Jun; Fu, Ya-Jing; Shang, Hong
2017-09-12
A small proportion of HIV-infected patients remain clinically and/or immunologically stable for years, including elite controllers (ECs) who have undetectable viremia (<50 copies/ml) and long-term nonprogressors (LTNPs) who maintain normal CD4 + T cell counts for prolonged periods (>10 years). However, the mechanism of nonprogression needs to be further resolved. In this study, a transcriptome meta-analysis was performed on nonprogressor and progressor microarray data to identify differential transcriptome pathways and potential biomarkers. Using the INMEX (integrative meta-analysis of expression data) program, we performed the meta-analysis to identify consistently differentially expressed genes (DEGs) in nonprogressors and further performed functional interpretation (gene ontology analysis and pathway analysis) of the DEGs identified in the meta-analysis. Five microarray datasets (81 cases and 98 controls in total), including whole blood, CD4 + and CD8 + T cells, were collected for meta-analysis. We determined that nonprogressors have reduced expression of important interferon-stimulated genes (ISGs), CD38, lymphocyte activation gene 3 (LAG-3) in whole blood, CD4 + and CD8 + T cells. Gene ontology (GO) analysis showed a significant enrichment in DEGs that function in the type I interferon signaling pathway. Upregulated pathways, including the PI3K-Akt signaling pathway in whole blood, cytokine-cytokine receptor interaction in CD4 + T cells and the MAPK signaling pathway in CD8 + T cells, were identified in nonprogressors compared with progressors. In each metabolic functional category, the number of downregulated DEGs was more than the upregulated DEGs, and almost all genes were downregulated DEGs in the oxidative phosphorylation (OXPHOS) and tricarboxylic acid (TCA) cycle in the three types of samples. Our transcriptomic meta-analysis provides a comprehensive evaluation of the gene expression profiles in major blood types of nonprogressors, providing new insights in the understanding of HIV pathogenesis and developing strategies to delay HIV disease progression.
Cotlet, Mircea; Huang, Yuan Zang; Chen, Jia -Shiang; ...
2016-03-24
We report an improved photosensitivity in few-layer tin disulfide (SnS 2) field-effect transistors(FETs) following doping with CdSe/ZnS core/shell quantum dots(QDs). The hybrid QD-SnS 2 FET devices achieve more than 500% increase in the photocurrent response compared with the starting SnS 2-only FET device and a spectral responsivity reaching over 650 A/W at 400 nm wavelength. The negligible electrical conductance in a control QD-only FET device suggests that the energy transfer between QDs and SnS 2 is the main mechanism responsible for the sensitization effect, which is consistent with the strong spectral overlap between QDphotoluminescence and SnS 2 optical absorption asmore » well as the large nominal donor-acceptor interspacing between QD core and SnS 2. Furthermore, we also find enhanced charge carrier mobility in hybrid QD-SnS 2 FETs which we attribute to a reduced contact Schottky barrier width due to an elevated background charge carrier density.« less
Cahyadi, Harsono; Iwatsuka, Junichi; Minamikawa, Takeo; Niioka, Hirohiko; Araki, Tsutomu; Hashimoto, Mamoru
2013-09-01
We develop a coherent anti-Stokes Raman scattering (CARS) microscopy system equipped with a tunable picosecond laser for high-speed wavelength scanning. An acousto-optic tunable filter (AOTF) is integrated in the laser cavity to enable wavelength scanning by varying the radio frequency waves applied to the AOTF crystal. An end mirror attached on a piezoelectric actuator and a pair of parallel plates driven by galvanometer motors are also introduced into the cavity to compensate for changes in the cavity length during wavelength scanning to allow synchronization with another picosecond laser. We demonstrate fast spectral imaging of 3T3-L1 adipocytes every 5 cm-1 in the Raman spectral region around 2850 cm-1 with an image acquisition time of 120 ms. We also demonstrate fast switching of Raman shifts between 2100 and 2850 cm-1, corresponding to CD2 symmetric stretching and CH2 symmetric stretching vibrations, respectively. The fast-switching CARS images reveal different locations of recrystallized deuterated and nondeuterated stearic acid.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marion, B.
2012-06-01
Although variation in photovoltaic (PV) performance is predominantly influenced by clouds, performance variations also exist for days with clear skies with different amounts of atmospheric constituents that absorb and reflect different amounts of radiation as it passes through the earth's atmosphere. The extent of the attenuation is determined by the mass of air and the amounts of water vapor, aerosols, and ozone that constitute the atmosphere for a particular day and location. Because these constituents selectively absorb radiation of particular wavelengths, their impact on PV performance is sensitive to the spectral response of the PV device. The impact may bemore » assessed by calculating the spectral mismatch correction. This approach was validated using PV module performance data at the National Renewable Energy Laboratory (NREL) for summer, fall, and winter days with clear skies. The standard deviation of daily efficiencies for single-crystal Si, a-Si/a-Si/a-Si:Ge, CdTe, and CIGS PV modules were reduced to 0.4% to 1.0% (relative) by correcting for spectral mismatch, temperature, and angle-of-incidence effects.« less
Biomarkers for Prostate and Bladder Cancer — EDRN Public Portal
CD26+ cancer cells and CD90+ tumor-associated stromal cells were sorted from tumor tissue. Dataset analysis with transcriptomes of CD26+ luminal, CD104+ basal, CD49a+ stromal and CD31+ endothelial was carried out to identify candidates: CD90, AGR2, BCMP11, CEACAM5, CRISP3. Quantitative protomics was applied to measure these proteins in urine samples.
Fraser, Kathleen; Abbas, Mariam; Hull, Peter R
2014-01-01
We previously demonstrated that repeated intradermal steroid injections administered at weekly intervals into positive patch-test sites induce hyposensitization and desensitization. To examine changes in CD4CD25CD127lo/ regulatory T cells during the attenuation of the patch-test response. Ten patients with known allergic contact dermatitis were patch tested weekly for 10 weeks. The patch-test site was injected intradermally with 2 mg triamcinolone. At weeks 1 and 7, a biopsy was performed on the patch-test site in 6 patients, and flow cytometry was performed assessing CD4CD25CD127lo/ regulatory T cells. Secondary outcomes were clinical score, reaction size, erythema, and temperature. Statistical analysis included regression, correlation, and repeated-measures analysis of variance. The percentage of CD4CD25CD127lo/ regulatory T cells, measured by flow cytometry, increased from week 1 to week 7 by an average of 19.2%. The average grade of patch-test reaction decreased from +++ (vesicular reaction) to ++ (palpable erythema). The mean drop in temperature following treatment was 0.28°C per week. The mean area decreased 8.6 mm/wk over 10 weeks. Intradermal steroid injections of weekly patch-test reactions resulted in hyposensitization of the allergic contact dermatitis reaction. CD4CD25CD127lo/ regulatory T cells showed a tendency to increase; however, further studies are needed to determine if this is significant.
Spectral compression algorithms for the analysis of very large multivariate images
Keenan, Michael R.
2007-10-16
A method for spectrally compressing data sets enables the efficient analysis of very large multivariate images. The spectral compression algorithm uses a factored representation of the data that can be obtained from Principal Components Analysis or other factorization technique. Furthermore, a block algorithm can be used for performing common operations more efficiently. An image analysis can be performed on the factored representation of the data, using only the most significant factors. The spectral compression algorithm can be combined with a spatial compression algorithm to provide further computational efficiencies.
Li, Zenghui; Xu, Bin; Yang, Jian; Song, Jianshe
2015-01-01
This paper focuses on suppressing spectral overlap for sub-band spectral estimation, with which we can greatly decrease the computational complexity of existing spectral estimation algorithms, such as nonlinear least squares spectral analysis and non-quadratic regularized sparse representation. Firstly, our study shows that the nominal ability of the high-order analysis filter to suppress spectral overlap is greatly weakened when filtering a finite-length sequence, because many meaningless zeros are used as samples in convolution operations. Next, an extrapolation-based filtering strategy is proposed to produce a series of estimates as the substitutions of the zeros and to recover the suppression ability. Meanwhile, a steady-state Kalman predictor is applied to perform a linearly-optimal extrapolation. Finally, several typical methods for spectral analysis are applied to demonstrate the effectiveness of the proposed strategy. PMID:25609038
Method of multivariate spectral analysis
Keenan, Michael R.; Kotula, Paul G.
2004-01-06
A method of determining the properties of a sample from measured spectral data collected from the sample by performing a multivariate spectral analysis. The method can include: generating a two-dimensional matrix A containing measured spectral data; providing a weighted spectral data matrix D by performing a weighting operation on matrix A; factoring D into the product of two matrices, C and S.sup.T, by performing a constrained alternating least-squares analysis of D=CS.sup.T, where C is a concentration intensity matrix and S is a spectral shapes matrix; unweighting C and S by applying the inverse of the weighting used previously; and determining the properties of the sample by inspecting C and S. This method can be used to analyze X-ray spectral data generated by operating a Scanning Electron Microscope (SEM) with an attached Energy Dispersive Spectrometer (EDS).
Martínez-Cáceres, E; Jaleco, A C; Res, P; Noteboom, E; Weijer, K; Spits, H
1998-07-01
In this paper we report that suspensions of human fetal thymocytes contain cells that express high levels of CD34 and Thy-1. These cells were characterized with regard to location within the thymus, phenotype, and function. Confocal laser scan analysis of frozen sections of fetal thymus with anti-CD34 and Thy-1 antibodies revealed that the double-labeled cells were located in the pericortical area. In addition, it was found that the CD34+Thy-1+ cells lacked CD45 and CD50, indicating that these cells are not of hematopoietic origin; this was confirmed by the finding that these cells could be cultured as adherent cells in a medium with cholera toxin and dexamethasone, but failed to grow in mixtures of hematopoietic growth factors. Further analysis indicated that most cultured CD34+Thy-1+ cells expressed cytokeratin (CK) 14 but lacked CK 13, suggesting that these cells are immature epithelial cells. Cultured CD34+Thy-1+ cells were able to induce differentiation of CD1-CD34+CD3-CD4-CD8- thymic precursors into CD4+CD8+ cells in a reaggregate culture in the absence of exogenous cytokines. The CD4+CD8+ cells that developed in these cultures did not express CD3, indicating that CD34+Thy-1+ thymic stromal cells are not capable of completing full T cell differentiation of thymic hematopoietic progenitor cells.
Prognostic value of CD44 expression in non-small cell lung cancer: a systematic review.
Luo, Zhuang; Wu, Rong-Rong; Lv, Liang; Li, Peng; Zhang, Li-Yan; Hao, Qing-Lin; Li, Wei
2014-01-01
CD44 is a potentially interesting prognostic marker and therapeutic target in non-small cell lung cancer (NSCLC). Although the expression of CD44 has been reported to correlate with poor prognosis of NSCLC in most literatures, some controversies still exist. Since the limited patient numbers within independent studies, here we performed a meta-analysis to clarify the correlations between CD44 expression and prognosis and clinicopathological features in NSCLC. Relevant literatures were identified using PubMed, EMBASE and CNKI (China National Knowledge Infrastructure) databases (up to February 2014). Data from eligible studies were extracted and included into meta-analysis using a random effects model. Studies were pooled. Summary hazard ratios (HR) and clinical parameters were calculated. We performed a final analysis of 1772 patients from 23 evaluable studies for Prognostic Value and 2167 patients from 28 evaluable studies for clinicopathological features. Our study shows that the pooled hazard ratio (HR) of overexpression CD44-V6 for overall survival in NSCLC was 1.63 [95% confidence interval (CI): 1.20-2.21] by univariate analysis and 1.29 (95% CI: 0.71-2.37) by multivariate analysis.The pooled HR of overexprssion panCD44 for overall survival in NSCLC was 1.53 (95% CI: 0.58-4.04) by univariate analysis and 3.00 (95% CI: 1.53-5.87) by multivariate analysis. Overexpression of CD44-V6 is associated with tumor differentiation (poor differentiation, OR = 1.66, 95% CI: 1.12-2.45), tumor histological type [squamous cell carcinomas (SCC), OR = 2.6, 95% CI: 1.63-5.02], clinical TMN stage (TMN stage III, OR = 2.22, 95% CI: 1.44-3.43) and lymph node metastasis (N1-3, 3.52, 95% CI: 2.08-5.93) in patients with NSCLC. However, there was no significant association between CD44-V6 and tumor size [T category, OR = 1.42, 95% CI: 0.73-2.78]. Our meta-analysis showed that CD44-V6 is an efficient prognostic factor for NSCLC. Overexpression of CD44-V6 was significantly associated with tumor differentiation, tumor histological type, clinical TMN stage and lymph node metastasis. However, there was no significant association between CD44-V6 and tumor size. Large prospective studies are now needed to confirm the clinical utility of CD44 as an independent prognostic marker.
Coindre, Sixtine; Tchitchek, Nicolas; Alaoui, Lamine; Vaslin, Bruno; Bourgeois, Christine; Goujard, Cecile; Avettand-Fenoel, Veronique; Lecuroux, Camille; Bruhns, Pierre; Le Grand, Roger; Beignon, Anne-Sophie; Lambotte, Olivier; Favier, Benoit
2018-01-01
CD32a has been proposed as a specific marker of latently HIV-infected CD4 + T cells. However, CD32a was recently found to be expressed on CD4 + T cells of healthy donors, leading to controversy on the relevance of this marker in HIV persistence. Here, we used mass cytometry to characterize the landscape and variation in the abundance of CD32a + CD4 + T cells during HIV infection. To this end, we analyzed CD32a + CD4 + T cells in primary HIV infection before and after effective combination antiretroviral therapy (cART) and in healthy donors. We found that CD32a + CD4 + T cells include heterogeneous subsets that are differentially affected by HIV infection. Our analysis revealed that naive ( N ), central memory ( CM ), and effector/memory ( Eff/Mem ) CD32a + CD4 + T-cell clusters that co-express LILRA2- and CD64-activating receptors were more abundant in primary HIV infection and cART stages. Conversely, LILRA2 - CD32a + CD4 + T-cell clusters of either the T N , T CM , or T Eff/Mem phenotype were more abundant in healthy individuals. Finally, an activated CD32a + CD4 + T Eff/Mem cell cluster co-expressing LILRA2, CD57, and NKG2C was more abundant in all HIV stages, particularly during primary HIV infection. Overall, our data show that multiple abundance modifications of CD32a + CD4 + T-cell subsets occur in the early phase of HIV infection, and some of which are conserved after effective cART. Our study brings a better comprehension of the relationship between CD32a expression and CD4 + T cells during HIV infection.
Analysis of the association between CD40 and CD40 ligand polymorphisms and systemic sclerosis.
Teruel, María; Simeon, Carmen P; Broen, Jasper; Vonk, Madelon C; Carreira, Patricia; Camps, Maria Teresa; García-Portales, Rosa; Delgado-Frías, Esmeralda; Gallego, Maria; Espinosa, Gerard; Beretta, Lorenzo; Airó, Paolo; Lunardi, Claudio; Riemekasten, Gabriela; Witte, Torsten; Krieg, Thomas; Kreuter, Alexander; Distler, Jörg H W; Hunzelmann, Nicolas; Koeleman, Bobby P; Voskuyl, Alexandre E; Schuerwegh, Annemie J; González-Gay, Miguel Angel; Radstake, Timothy R D J; Martin, Javier
2012-06-25
The aim of the present study was to investigate the possible role of CD40 and CD40 ligand (CD40LG) genes in the susceptibility and phenotype expression of systemic sclerosis (SSc). In total, 2,670 SSc patients and 3,245 healthy individuals from four European populations (Spain, Germany, The Netherlands, and Italy) were included in the study. Five single-nucleotide polymorphisms (SNPs) of CD40 (rs1883832, rs4810485, rs1535045) and CD40LG (rs3092952, rs3092920) were genotyped by using a predesigned TaqMan allele-discrimination assay technology. Meta-analysis was assessed to determine whether an association exists between the genetic variants and SSc or its main clinical subtypes. No evidence of association between CD40 and CD40LG genes variants and susceptibility to SSc was observed. Similarly, no significant statistical differences were observed when SSc patients were stratified by the clinical subtypes, the serologic features, and pulmonary fibrosis. Our results do not suggest an important role of CD40 and CD40LG gene polymorphisms in the susceptibility to or clinical expression of SSc.
Dean, W.E.; Zheng, Yen; Ortiz, J.D.; VanGeen, A.
2006-01-01
Concentrations of organic carbon (orgC), cadmium (Cd), and molybdenum (Mo) were measured in two sediment cores raised from depths of 430 and 700 m within the oxygen-minimum zone (OMZ) off southern Baja California at a temporal resolution of e10.5 kyr over the past 52 kyr. These records are supplemented with diffuse spectral reflectance (DSR) measurements obtained on board ship soon after collection at a resolution of e10.05 kyr. In the core from 700 m depth, a component extracted from the DSR data and the three geochemical proxies generally vary in concert with each other and over a wide range (4-22% orgC; 1-40 mg/kg Cd; 5-120 mg/kg Mo). Intervals of increased orgC, Cd, and Mo accumulation generally correspond to warm periods recorded in the oxygen-isotopic composition of Greenland ice, with the exception of the Bolling/Allerod which is only weakly expressed off Baja California. Concentrations of the biogenic proxies are higher in the core from 430 m depth, but erratic sediment accumulation before 15 ka precludes dating of the older intervals that are laminated and contain elevated orgC, Cd, and Mo concentrations. The new data provide further evidence of an intimate teleconnection between global climate and the intensity of the OMZ and/or productivity along the western margin of North America. On the basis of a comparison with Cd and Mo records collected elsewhere in the region, we conclude that productivity may actually have varied off southern Baja California by no more than a factor of 2 over the past 52 kyr. Copyright 2006 by the American Geophysical Union.
Santos, Mirian C; Nóbrega, Joaquim A; Cadore, Solange
2011-06-15
A procedure based on the use of a quadrupole inductively coupled plasma-mass spectrometer equipped with a collision-reaction interface (CRI) for control of spectral overlap interferences was developed for simultaneous determination of Cd, Cr, Hg, and Pb in plastics from waste electrical and electronic equipment (WEEE). The injection of H(2) and He (80 and 60 mL min(-1), respectively) into the sampled plasma, colliding and reacting with potentially interfering polyatomic ions, allows interference-free determination of chromium via its isotopes (52)Cr and (53)Cr that are freed from overlap due to the occurrence of (40)Ar(12)C(+), (40)Ar(12)C(1)H(+), (36)S(16)O(+) or (1)H(36)S(16)O(+). Cadmium, Hg and Pb were directly determined via their isotopes (110)Cd, (111)Cd, (112)Cd, (199)Hg, (200)Hg, (201)Hg, (202)Hg, (206)Pb, (207)Pb, and (208)Pb, without using CRI. The CRI can be quickly activated or deactivated before each analyte measurement. Limits of detection for (52)Cr were 0.04 or 0.14 μg L(-1) with He or H(2) injected in CRI. Cadmium and Pb have LODs between 0.02 and 0.08 μg L(-1) and Hg had 0.93-0.98 μg L(-1), without using CRI. Analyte concentrations for samples varied from 16 to 43, 1 to 11, 4 to 12, and 5 to 13 mg kg(-1) for Cr, Cd, Hg and Pb, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.
Peculiar Expression of CD3-Epsilon in Kidney of Ginbuna Crucian Carp.
Miyazawa, Ryuichiro; Murata, Norifumi; Matsuura, Yuta; Shibasaki, Yasuhiro; Yabu, Takeshi; Nakanishi, Teruyuki
2018-01-01
TCR/CD3 complex is composed of the disulfide-linked TCR-αβ heterodimer that recognizes the antigen as a peptide presented by the MHC, and non-covalently paired CD3γε- and δε-chains together with disulfide-linked ζ-chain homodimers. The CD3 chains play key roles in T cell development and T cell activation. In the present study, we found nor or extremely lower expression of CD3ε in head- and trunk-kidney lymphocytes by flow cytometric analysis, while CD3ε was expressed at the normal level in lymphocytes from thymus, spleen, intestine, gill, and peripheral blood. Furthermore, CD4-1 + and CD8α + T cells from kidney express Zap-70, but not CD3ε, while the T cells from other tissues express both Zap-70 and CD3ε, although expression of CD3ε was low. Quantitative analysis of mRNA expression revealed that the expression level of T cell-related genes including tcrb, cd3 ε, zap-70 , and lck in CD4-1 + and CD8α + T cells was not different between kidney and spleen. Western blot analysis showed that CD3ε band was detected in the cell lysates of spleen but not kidney. To be interested, CD3ε-positive cells greatly increased after 24 h in in vitro culture of kidney leukocytes. Furthermore, expression of CD3ε in both transferred kidney and spleen leukocytes was not detected or very low in kidney, while both leukocytes expressed CD3ε at normal level in spleen when kidney and spleen leukocytes were injected into the isogeneic recipient. Lower expression of CD3ε was also found in kidney T lymphocytes of goldfish and carp. These results indicate that kidney lymphocytes express no or lower level of CD3ε protein in the kidney, although the mRNA of the gene was expressed. Here, we discuss this phenomenon from the point of function of kidney as reservoir for T lymphocytes in teleost, which lacks lymph node and bone marrow.
García-Molina, María Dolores; García-Olmo, Juan; Barro, Francisco
2016-01-01
The aim of this work was to assess the ability of Near Infrared Spectroscopy (NIRS) to distinguish wheat lines with low gliadin content, obtained by RNA interference (RNAi), from non-transgenic wheat lines. The discriminant analysis was performed using both whole grain and flour. The transgenic sample set included 409 samples for whole grain sorting and 414 samples for flour experiments, while the non-transgenic set consisted of 126 and 156 samples for whole grain and flour, respectively. Samples were scanned using a Foss-NIR Systems 6500 System II instrument. Discrimination models were developed using the entire spectral range (400-2500 nm) and ranges of 400-780 nm, 800-1098 nm and 1100-2500 nm, followed by analysis of means of partial least square (PLS). Two external validations were made, using samples from the years 2013 and 2014 and a minimum of 99% of the flour samples and 96% of the whole grain samples were classified correctly. The results demonstrate the ability of NIRS to successfully discriminate between wheat samples with low-gliadin content and wild types. These findings are important for the development and analysis of foodstuff for celiac disease (CD) patients to achieve better dietary composition and a reduction in disease incidence.
Characterization and functional analyses of a novel chicken CD8a variant X1 (CD8a1)
USDA-ARS?s Scientific Manuscript database
We provide the first description of cloning, as well as structural and functional analysis of a novel variant in the chicken CD8alpha family, termed the CD8-alpha X1 (CD8alpha1) gene. Multiple alignment of CD8alpha1 with known CD8alpha and beta sequences of other species revealed relatively low con...
Spectral and Temporal Laser Fluorescence Analysis Such as for Natural Aquatic Environments
NASA Technical Reports Server (NTRS)
Chekalyuk, Alexander (Inventor)
2015-01-01
An Advanced Laser Fluorometer (ALF) can combine spectrally and temporally resolved measurements of laser-stimulated emission (LSE) for characterization of dissolved and particulate matter, including fluorescence constituents, in liquids. Spectral deconvolution (SDC) analysis of LSE spectral measurements can accurately retrieve information about individual fluorescent bands, such as can be attributed to chlorophyll-a (Chl-a), phycobiliprotein (PBP) pigments, or chromophoric dissolved organic matter (CDOM), among others. Improved physiological assessments of photosynthesizing organisms can use SDC analysis and temporal LSE measurements to assess variable fluorescence corrected for SDC-retrieved background fluorescence. Fluorescence assessments of Chl-a concentration based on LSE spectral measurements can be improved using photo-physiological information from temporal measurements. Quantitative assessments of PBP pigments, CDOM, and other fluorescent constituents, as well as basic structural characterizations of photosynthesizing populations, can be performed using SDC analysis of LSE spectral measurements.
Plesa, Adriana; Dumontet, Charles; Mattei, Eve; Tagoug, Ines; Hayette, Sandrine; Sujobert, Pierre; Tigaud, Isabelle; Pages, Marie Pierre; Chelghoum, Youcef; Baracco, Fiorenza; Labussierre, Helene; Ducastelle, Sophie; Paubelle, Etienne; Nicolini, Franck Emmanuel; Elhamri, Mohamed; Campos, Lydia; Plesa, Claudiu; Morisset, Stéphane; Salles, Gilles; Bertrand, Yves; Michallet, Mauricette; Thomas, Xavier
2017-12-26
To evaluate the importance of the CD34+CD38- cell population when compared to the CD34+CD38+/low and CD34+CD38+/high leukemic cell sub-populations and to determine its correlations with leukemia characteristics and known prognostic factors, as well as with response to therapy and survival. Two hundred bone marrow samples were obtained at diagnosis from 200 consecutive patients with newly diagnosed acute myeloid leukemia (AML) were studied between September 2008 and December 2010 at our Institution (Hematology Department, Lyon, France). The CD34/CD38 cell profile was analyzed by multiparameter flowcytometry approach using 8C panels and FACS CANTO and Diva software (BD Bioscience). We analyzed CD34 and CD38 expression in bone marrow samples of 200 AML patients at diagnosis, and investigated the prognostic value of the most immature CD34+CD38- population. Using a cut-off value of 1% of CD34+CD38- from total "bulk leukemic cells" we found that a high (> 1%) level of CD34+CD38- blasts at diagnosis was correlated with advanced age, adverse cytogenetics as well as with a lower rate of complete response after induction and shorter disease-free survival. In a multivariate analysis considering age, leukocytosis, the % of CD34+ blasts cells and the standardized cytogenetic and molecular risk subgroups, a percentage of CD34+CD38- leukemic cells > 1% was an independent predictor of DFS [HR = 2.8 (1.02-7.73), P = 0.04] and OS [HR = 2.65 (1.09-6.43), P = 0.03]. Taken together, these results show that a CD34/CD38 "backbone" for leukemic cell analysis by multicolour flowcytometry at diagnosis provides useful prognostic information.
Expression of CD30 in patients with acute graft-versus-host disease.
Chen, Yi-Bin; McDonough, Sean; Hasserjian, Robert; Chen, Heidi; Coughlin, Erin; Illiano, Christina; Park, In Sun; Jagasia, Madan; Spitzer, Thomas R; Cutler, Corey S; Soiffer, Robert J; Ritz, Jerome
2012-07-19
Acute GVHD (aGVHD) remains a major source of morbidity after allogeneic hematopoietic cell transplantation. CD30 is a cell-surface protein expressed on certain activated T cells. We analyzed CD30 expression on peripheral blood T-cell subsets and soluble CD30 levels in 26 patients at the time of presentation of aGVHD, before the initiation of treatment, compared with 27 patients after hematopoietic cell transplantation without aGVHD (NONE). Analysis by flow cytometry showed that patients with aGVHD had a greater percentage of CD30 expressing CD8(+) T cells with the difference especially pronounced in the central memory subset (CD8(+)CD45RO(+)CD62L(+)): GVHD median 12.4% (range, 0.8%-33.4%) versus NONE 2.1% (0.7%, 17.5%), P < .001. There were similar levels of CD30 expression in naive T cells, CD4(+) T cells, and regulatory (CD4(+)CD127(low)CD25(+)) T cells. Plasma levels of soluble CD30 were significantly greater in patients with GVHD: median 61.7 ng/mL (range, 9.8-357.1 ng/mL) versus 17.4 (range, 3.7-142.4 ng/mL) in NONE (P < .001). Immunohistochemical analysis of affected intestinal tissue showed many CD30(+) infiltrating lymphocytes present. These results suggest that CD30 expression on CD8(+) T-cell subsets or plasma levels of soluble CD30 may be a potential biomarker for aGVHD. CD30 may also represent a target for novel therapeutic approaches for aGVHD.
Expression of CD30 in patients with acute graft-versus-host disease
McDonough, Sean; Hasserjian, Robert; Chen, Heidi; Coughlin, Erin; Illiano, Christina; Park, In Sun; Jagasia, Madan; Spitzer, Thomas R.; Cutler, Corey S.; Soiffer, Robert J.; Ritz, Jerome
2012-01-01
Acute GVHD (aGVHD) remains a major source of morbidity after allogeneic hematopoietic cell transplantation. CD30 is a cell-surface protein expressed on certain activated T cells. We analyzed CD30 expression on peripheral blood T-cell subsets and soluble CD30 levels in 26 patients at the time of presentation of aGVHD, before the initiation of treatment, compared with 27 patients after hematopoietic cell transplantation without aGVHD (NONE). Analysis by flow cytometry showed that patients with aGVHD had a greater percentage of CD30 expressing CD8+ T cells with the difference especially pronounced in the central memory subset (CD8+CD45RO+CD62L+): GVHD median 12.4% (range, 0.8%-33.4%) versus NONE 2.1% (0.7%, 17.5%), P < .001. There were similar levels of CD30 expression in naive T cells, CD4+ T cells, and regulatory (CD4+CD127lowCD25+) T cells. Plasma levels of soluble CD30 were significantly greater in patients with GVHD: median 61.7 ng/mL (range, 9.8-357.1 ng/mL) versus 17.4 (range, 3.7-142.4 ng/mL) in NONE (P < .001). Immunohistochemical analysis of affected intestinal tissue showed many CD30+ infiltrating lymphocytes present. These results suggest that CD30 expression on CD8+ T-cell subsets or plasma levels of soluble CD30 may be a potential biomarker for aGVHD. CD30 may also represent a target for novel therapeutic approaches for aGVHD. PMID:22661699
Classification of river water pollution using Hyperion data
NASA Astrophysics Data System (ADS)
Kar, Soumyashree; Rathore, V. S.; Champati ray, P. K.; Sharma, Richa; Swain, S. K.
2016-06-01
A novel attempt is made to use hyperspectral remote sensing to identify the spatial variability of metal pollutants present in river water. It was also attempted to classify the hyperspectral image - Earth Observation-1 (EO-1) Hyperion data of an 8 km stretch of the river Yamuna, near Allahabad city in India depending on its chemical composition. For validating image analysis results, a total of 10 water samples were collected and chemically analyzed using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). Two different spectral libraries from field and image data were generated for the 10 sample locations. Advanced per-pixel supervised classifications such as Spectral Angle Mapper (SAM), SAM target finder using BandMax and Support Vector Machine (SVM) were carried out along with the unsupervised clustering procedure - Iterative Self-Organizing Data Analysis Technique (ISODATA). The results were compared and assessed with respect to ground data. Analytical Spectral Devices (ASD), Inc. spectroradiometer, FieldSpec 4 was used to generate the spectra of the water samples which were compiled into a spectral library and used for Spectral Absorption Depth (SAD) analysis. The spectral depth pattern of image and field spectral libraries was found to be highly correlated (correlation coefficient, R2 = 0.99) which validated the image analysis results with respect to the ground data. Further, we carried out a multivariate regression analysis to assess the varying concentrations of metal ions present in water based on the spectral depth of the corresponding absorption feature. Spectral Absorption Depth (SAD) analysis along with metal analysis of field data revealed the order in which the metals affected the river pollution, which was in conformity with the findings of Central Pollution Control Board (CPCB). Therefore, it is concluded that hyperspectral imaging provides opportunity that can be used for satellite based remote monitoring of water quality from space.
Automatic classification of spectral units in the Aristarchus plateau
NASA Astrophysics Data System (ADS)
Erard, S.; Le Mouelic, S.; Langevin, Y.
1999-09-01
A reduction scheme has been recently proposed for the NIR images of Clementine (Le Mouelic et al, JGR 1999). This reduction has been used to build an integrated UVvis-NIR image cube of the Aristarchus region, from which compositional and maturity variations can be studied (Pinet et al, LPSC 1999). We will present an analysis of this image cube, providing a classification in spectral types and spectral units. The image cube is processed with Gmode analysis using three different data sets: Normalized spectra provide a classification based mainly on spectral slope variations (ie. maturity and volcanic glasses). This analysis discriminates between craters plus ejecta, mare basalts, and DMD. Olivine-rich areas and Aristarchus central peak are also recognized. Continuum-removed spectra provide a classification more related to compositional variations, which correctly identifies olivine and pyroxenes-rich areas (in Aristarchus, Krieger, Schiaparelli\\ldots). A third analysis uses spectral parameters related to maturity and Fe composition (reflectance, 1 mu m band depth, and spectral slope) rather than intensities. It provides the most spatially consistent picture, but fails in detecting Vallis Schroeteri and DMDs. A supplementary unit, younger and rich in pyroxene, is found on Aristarchus south rim. In conclusion, Gmode analysis can discriminate between different spectral types already identified with more classic methods (PCA, linear mixing\\ldots). No previous assumption is made on the data structure, such as endmembers number and nature, or linear relationship between input variables. The variability of the spectral types is intrinsically accounted for, so that the level of analysis is always restricted to meaningful limits. A complete classification should integrate several analyses based on different sets of parameters. Gmode is therefore a powerful light toll to perform first look analysis of spectral imaging data. This research has been partly founded by the French Programme National de Planetologie.
Ichikawa, N; Kitano, K; Ito, T; Nakazawa, T; Shimodaira, S; Ishida, F; Kiyosawa, K
1999-04-01
We report a case of granular lymphocyte proliferative disorder accompanied with hemolytic anemia and neutropenia. Phenotypes of the cells were T cell receptor gammadelta+ CD3+ CD4- CD8+ CD16+ CD56- CD57-. Southern blot analysis of T cell receptor beta and gamma chains demonstrated rearranged bands in both. Chromosomal analysis after IL-2 stimulation showed deletion of chromosome 6. Sorted gammadelta+ T cells showed an increase in Fas ligand expression compared with the levels in sorted alphabeta+ T cells. The expression of Fas ligand on these gammadelta+ T cells increased after IL-2 stimulation. The patient's anemia improved along with a decrease in granular lymphocyte count and disappearance of the abnormal karyotype without treatment. The expression of Fas ligand may be involved in spontaneous regression of granular lymphocyte proliferation with hemolytic anemia.
NASA Astrophysics Data System (ADS)
Osuntokun, Jejenija; Ajibade, Peter A.
2015-07-01
[Cd(diptu)2(ced)], [Cd(diptu)2(ced)(bpy)], [Cd(diptu)2(ced)(phen)], (where diptu = diisopropyl thiourea; ced = 1-cyano-1-carboethoxylethylene-2,2‧-dithiolate; bpy = 2,2‧-bipyridine and phen = 1,10-phenanthroline) have been prepared and used as single source precursors for the preparation of hexadecylamine capped CdS nanoparticles. The precursor complexes were characterized by elemental analysis, FTIR and TGA. The structural properties of the nanoparticles were investigated using powder X-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy techniques (SEM). The optical properties of the nanoparticles were studied using UV-Visible and photoluminescence spectroscopy. The XRD analysis showed that the nanoparticles were indexed to the hexagonal phase of CdS and the TEM results showed CdS nanoparticles with average crystallite sizes of 4.00-8.80 nm.
[Estimation of Hunan forest carbon density based on spectral mixture analysis of MODIS data].
Yan, En-ping; Lin, Hui; Wang, Guang-xing; Chen, Zhen-xiong
2015-11-01
With the fast development of remote sensing technology, combining forest inventory sample plot data and remotely sensed images has become a widely used method to map forest carbon density. However, the existence of mixed pixels often impedes the improvement of forest carbon density mapping, especially when low spatial resolution images such as MODIS are used. In this study, MODIS images and national forest inventory sample plot data were used to conduct the study of estimation for forest carbon density. Linear spectral mixture analysis with and without constraint, and nonlinear spectral mixture analysis were compared to derive the fractions of different land use and land cover (LULC) types. Then sequential Gaussian co-simulation algorithm with and without the fraction images from spectral mixture analyses were employed to estimate forest carbon density of Hunan Province. Results showed that 1) Linear spectral mixture analysis with constraint, leading to a mean RMSE of 0.002, more accurately estimated the fractions of LULC types than linear spectral and nonlinear spectral mixture analyses; 2) Integrating spectral mixture analysis model and sequential Gaussian co-simulation algorithm increased the estimation accuracy of forest carbon density to 81.5% from 74.1%, and decreased the RMSE to 5.18 from 7.26; and 3) The mean value of forest carbon density for the province was 30.06 t · hm(-2), ranging from 0.00 to 67.35 t · hm(-2). This implied that the spectral mixture analysis provided a great potential to increase the estimation accuracy of forest carbon density on regional and global level.
Spectral analysis for GNSS coordinate time series using chirp Fourier transform
NASA Astrophysics Data System (ADS)
Feng, Shengtao; Bo, Wanju; Ma, Qingzun; Wang, Zifan
2017-12-01
Spectral analysis for global navigation satellite system (GNSS) coordinate time series provides a principal tool to understand the intrinsic mechanism that affects tectonic movements. Spectral analysis methods such as the fast Fourier transform, Lomb-Scargle spectrum, evolutionary power spectrum, wavelet power spectrum, etc. are used to find periodic characteristics in time series. Among spectral analysis methods, the chirp Fourier transform (CFT) with less stringent requirements is tested with synthetic and actual GNSS coordinate time series, which proves the accuracy and efficiency of the method. With the length of series only limited to even numbers, CFT provides a convenient tool for windowed spectral analysis. The results of ideal synthetic data prove CFT accurate and efficient, while the results of actual data show that CFT is usable to derive periodic information from GNSS coordinate time series.
Determination of awareness in patients with severe brain injury using EEG power spectral analysis
Goldfine, Andrew M.; Victor, Jonathan D.; Conte, Mary M.; Bardin, Jonathan C.; Schiff, Nicholas D.
2011-01-01
Objective To determine whether EEG spectral analysis could be used to demonstrate awareness in patients with severe brain injury. Methods We recorded EEG from healthy controls and three patients with severe brain injury, ranging from minimally conscious state (MCS) to locked-in-state (LIS), while they were asked to imagine motor and spatial navigation tasks. We assessed EEG spectral differences from 4 to 24 Hz with univariate comparisons (individual frequencies) and multivariate comparisons (patterns across the frequency range). Results In controls, EEG spectral power differed at multiple frequency bands and channels during performance of both tasks compared to a resting baseline. As patterns of signal change were inconsistent between controls, we defined a positive response in patient subjects as consistent spectral changes across task performances. One patient in MCS and one in LIS showed evidence of motor imagery task performance, though with patterns of spectral change different from the controls. Conclusion EEG power spectral analysis demonstrates evidence for performance of mental imagery tasks in healthy controls and patients with severe brain injury. Significance EEG power spectral analysis can be used as a flexible bedside tool to demonstrate awareness in brain-injured patients who are otherwise unable to communicate. PMID:21514214
Critical Role of CD8 T Cells in Mediating Sex-Based Differences in a Murine Model of Lupus
2009-08-21
into female transfers (fF) mice that was reduced in CD8 depleted fF mice. Flow cytometry analysis showed increased numbers of splenic...splenocytes were first analyzed by flow cytometry for CD4 and CD8 T cells and F1 mice received either: a) unfractionated splenocytes (CD8 intactF1...using magnetic beads purchased from Invitrogen (Carlsbad, CA) according to the manufacturer’s instructions. Flow cytometry analysis before cell
Mutoh, Yoshikazu; Nishijima, Takeshi; Inaba, Yosuke; Tanaka, Noriko; Kikuchi, Yoshimi; Gatanaga, Hiroyuki; Oka, Shinichi
2018-03-02
The extent and duration of long-term recovery of CD4 count, CD4%, and CD4/CD8 ratio after initiation of combination antiretroviral therapy (cART) in patients with suppressed viral load are largely unknown. HIV-1 infected patients who started cART between January 2004 and January 2012 and showed persistent viral suppression (<200 copies/mL) for at least 4 years were followed up at AIDS Clinical Center, Tokyo. Change point analysis was used to determine the time point where CD4 count recovery shows a plateau, and linear mixed model was applied to estimate CD4 count at the change point. Data of 752 patients were analyzed [93% males, median age 38, median baseline CD4 count 172/µL (IQR, 62-253), CD4% 13.8% (IQR, 7.7-18.5), and CD4/8 ratio 0.23 (IQR, 0.12-0.35)]. The median follow-up period was 81.2 months and 91 (12.1%) patients were followed for >10 years. Change point analysis showed that CD4 count, CD4%, and CD4/CD8 ratio, continued to increase until 78.6, 62.2, and 64.3 months, respectively, with adjusted mean of 590 /µL (95%CI 572-608), 29.5% (29-30.1), and 0.89 (0.86-0.93), respectively, at the change point. Although 73.8% of the study patients achieved CD4 count ≥500 /μL, 48.2% of the patients with baseline CD4 count <100 /μL did not achieve CD4 count ≥500 /μL. Neither CD4% nor CD4/CD8 ratio normalized in a majority of patients. The results showed lack of normalization of CD4 count, CD4%, and CD4/CD8 ratio to the levels seen in healthy individuals even after long-term successful cART in patients with suppressed viral load.
Hardy, W Reef; Moldovan, Nicanor I; Moldovan, Leni; Livak, Kenneth J; Datta, Krishna; Goswami, Chirayu; Corselli, Mirko; Traktuev, Dmitry O; Murray, Iain R; Péault, Bruno; March, Keith
2017-05-01
Adipose tissue is a rich source of multipotent mesenchymal stem-like cells, located in the perivascular niche. Based on their surface markers, these have been assigned to two main categories: CD31 - /CD45 - /CD34 + /CD146 - cells (adventitial stromal/stem cells [ASCs]) and CD31 - /CD45 - /CD34 - /CD146 + cells (pericytes [PCs]). These populations display heterogeneity of unknown significance. We hypothesized that aldehyde dehydrogenase (ALDH) activity, a functional marker of primitivity, could help to better define ASC and PC subclasses. To this end, the stromal vascular fraction from a human lipoaspirate was simultaneously stained with fluorescent antibodies to CD31, CD45, CD34, and CD146 antigens and the ALDH substrate Aldefluor, then sorted by fluorescence-activated cell sorting. Individual ASCs (n = 67) and PCs (n = 73) selected from the extremities of the ALDH-staining spectrum were transcriptionally profiled by Fluidigm single-cell quantitative polymerase chain reaction for a predefined set (n = 429) of marker genes. To these single-cell data, we applied differential expression and principal component and clustering analysis, as well as an original gene coexpression network reconstruction algorithm. Despite the stochasticity at the single-cell level, covariation of gene expression analysis yielded multiple network connectivity parameters suggesting that these perivascular progenitor cell subclasses possess the following order of maturity: (a) ALDH br ASC (most primitive); (b) ALDH dim ASC; (c) ALDH br PC; (d) ALDH dim PC (least primitive). This order was independently supported by specific combinations of class-specific expressed genes and further confirmed by the analysis of associated signaling pathways. In conclusion, single-cell transcriptional analysis of four populations isolated from fat by surface markers and enzyme activity suggests a developmental hierarchy among perivascular mesenchymal stem cells supported by markers and coexpression networks. Stem Cells 2017;35:1273-1289. © 2017 AlphaMed Press.
Huhe, Muren; Liu, Shuangshuang; Zhang, Yang; Zhang, Zheng; Chen, Zhinan
2017-05-01
The aim of the present study was to investigate the prognostic significance of the expression of transcription factors, c-Fos, c-Jun and transmembrane protein CD147, in urothelial carcinoma of the bladder (UCB). The current study investigated the clinical significance of these factors in the development, progression and survival analysis of UCB. Immunohistochemistry was employed to analyze c‑Fos, c‑Jun and CD147 expression in 41 UCB cases and 34 non‑cancerous human bladder tissues. These results were scored in a semi‑quantitative manner based on the intensity and percentage of tumor cells that presented immunoreactivity. Protein levels of CD147, c‑Fos and c‑Jun expression were upregulated in 22 (53.7%), 10 (24.4%) and 9 (22.0%) UCB cases, respectively. High levels of c‑Jun correlated with the AJCC cancer staging manual (7th edition; P=0.038). Univariate analysis revealed that upregulated CD147 (P=0.038) or c‑Jun (P=0.008) was associated with poor overall survival (OS), respectively. Further analysis revealed that either CD147‑c‑Fos‑c‑Jun co‑expression (P=0.004), or CD147‑c‑Jun co‑expression (P=0.037) and c‑Fos‑c‑Jun co‑expression (P<0.001) were associated with poor OS. Multivariate analysis suggested that either upregulation of CD147, c‑Jun or c‑Fos were independent risk indicators for death in UCB patients. Increased expression of c‑Jun or CD147, as well as co‑expression of CD147‑c‑Jun, c‑Jun‑c‑Fos or CD147‑c‑Jun‑c‑Fos has prognostic significance for UCB patients. Therefore, high CD147 and c‑Jun expression may serve roles in tumor progression and may be diagnostic and therapeutic targets in UCB whether alone or in combination.
Prognostic implications of adhesion molecule expression in colorectal cancer.
Seo, Kyung-Jin; Kim, Maru; Kim, Jeana
2015-01-01
Research on the expression of adhesion molecules, E-cadherin (ECAD), CD24, CD44 and osteopontin (OPN) in colorectal cancer (CRC) has been limited, even though CRC is one of the leading causes of cancer-related deaths. This study was conducted to evaluate the expression of adhesion molecules in CRC and to determine their relationships with clinicopathologic variables, and the prognostic significance. The expression of ECAD, CD24, CD44 and OPN was examined in 174 stage II and III CRC specimens by immunohistochemistry of TMA. Negative ECAD expression was significantly correlated with advanced nodal stage and poor tumor differentiation. Multivariate analysis showed that both negative expression of ECAD and positive expression of CD24 were independent prognostic factors for disease-free survival (DFS) in CRC patients (P<0.001, relative risk [RR] = 5.596, 95% CI = 2.712-11.549; P = 0.038, RR = 3.768, 95% CI = 1.077-13.185, respectively). However, for overall survival (OS), only ECAD negativity showed statistically significant results in multivariate analysis (P<0.001, RR = 4.819, 95% CI = 2.515-9.234). Positive expression of CD24 was associated with poor OS in univariate analysis but was of no prognostic value in multivariate analysis. In conclusion, our study suggests that among these four adhesion molecules, ECAD and CD24 expression can be considered independent prognostic factors. The role of CD44 and OPN may need further evaluation.
Prognostic implications of adhesion molecule expression in colorectal cancer
Seo, Kyung-Jin; Kim, Maru; Kim, Jeana
2015-01-01
Research on the expression of adhesion molecules, E-cadherin (ECAD), CD24, CD44 and osteopontin (OPN) in colorectal cancer (CRC) has been limited, even though CRC is one of the leading causes of cancer-related deaths. This study was conducted to evaluate the expression of adhesion molecules in CRC and to determine their relationships with clinicopathologic variables, and the prognostic significance. The expression of ECAD, CD24, CD44 and OPN was examined in 174 stage II and III CRC specimens by immunohistochemistry of TMA. Negative ECAD expression was significantly correlated with advanced nodal stage and poor tumor differentiation. Multivariate analysis showed that both negative expression of ECAD and positive expression of CD24 were independent prognostic factors for disease-free survival (DFS) in CRC patients (P<0.001, relative risk [RR] = 5.596, 95% CI = 2.712-11.549; P = 0.038, RR = 3.768, 95% CI = 1.077-13.185, respectively). However, for overall survival (OS), only ECAD negativity showed statistically significant results in multivariate analysis (P<0.001, RR = 4.819, 95% CI = 2.515-9.234). Positive expression of CD24 was associated with poor OS in univariate analysis but was of no prognostic value in multivariate analysis. In conclusion, our study suggests that among these four adhesion molecules, ECAD and CD24 expression can be considered independent prognostic factors. The role of CD44 and OPN may need further evaluation. PMID:26097606
Elevated CD147 expression is associated with shorter overall survival in non-small cell lung cancer.
Zhang, Xiaojun; Tian, Tian; Zhang, Xiaofeng; Liu, Changting; Fang, Xiangqun
2017-06-06
A number of studies have reported on the prognostic role of CD147 expression in non-small cell lung cancer (NSCLC); however, the results remain controversial. This study aims to investigate the impact of CD147 on the prognosis of NSCLC by means of a meta-analysis. A literature search was performed for relevant studies published before October 29, 2016. The hazard ratios (HRs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated as effective measures. Sensitivity analysis and publication bias examination were also conducted. Ten eligible studies with a total of 1605 patients were included in this meta-analysis. CD147 overexpression was correlated with poor overall survival (OS) (HR=1.59, 95% CI=1.32-1.91, p<0.001). Elevated CD147 expression was associated with the presence of lymph node metastasis (OR=2.31, 95% CI=1.74-3.07, p<0.001) and advanced TNM stage (OR=3.03, 95% CI=1.24-7.39, p=0.015). However, no significant association between CD147 and sex, age, differentiation, or histology was found. No evidence of significant publication bias was identified. This meta-analysis revealed that overexpression of CD147 was associated with shorter OS, the presence of lymph node metastasis and advanced TNM stage in NSCLC. Therefore, CD147 could serve as a potential prognostic marker for NSCLC.
Elevated CD147 expression is associated with shorter overall survival in non-small cell lung cancer
Zhang, Xiaojun; Tian, Tian; Zhang, Xiaofeng; Liu, Changting; Fang, Xiangqun
2017-01-01
A number of studies have reported on the prognostic role of CD147 expression in non-small cell lung cancer (NSCLC); however, the results remain controversial. This study aims to investigate the impact of CD147 on the prognosis of NSCLC by means of a meta-analysis. A literature search was performed for relevant studies published before October 29, 2016. The hazard ratios (HRs), odds ratios (ORs), and 95% confidence intervals (CIs) were calculated as effective measures. Sensitivity analysis and publication bias examination were also conducted. Ten eligible studies with a total of 1605 patients were included in this meta-analysis. CD147 overexpression was correlated with poor overall survival (OS) (HR=1.59, 95% CI=1.32–1.91, p<0.001). Elevated CD147 expression was associated with the presence of lymph node metastasis (OR=2.31, 95% CI=1.74–3.07, p<0.001) and advanced TNM stage (OR=3.03, 95% CI=1.24–7.39, p=0.015). However, no significant association between CD147 and sex, age, differentiation, or histology was found. No evidence of significant publication bias was identified. This meta-analysis revealed that overexpression of CD147 was associated with shorter OS, the presence of lymph node metastasis and advanced TNM stage in NSCLC. Therefore, CD147 could serve as a potential prognostic marker for NSCLC. PMID:28445149
NASA Technical Reports Server (NTRS)
Wilson, A. B.; Seilly, D.; Willers, C.; Vannais, D. B.; McGraw, M.; Waldren, C. A.; Hei, T. K.; Davies, A.; Chatterjee, A. (Principal Investigator)
1999-01-01
S1 cell membrane antigen is encoded by the MIC1 gene on human chromosome 11. This antigen has been widely used as a marker for studies in gene mapping or in analysis of mutagen-induced gene deletions/mutations, which utilized the human-hamster hybrid cell-line, AL-J1, carrying human chromosome 11. Evidence is presented here which identifies S1 as an epitope of CD59, a cell membrane complement inhibiting protein. E7.1 monoclonal antibody, specific for the S1 determinant, was found to react strongly with membrane CD59 in Western blotting, and to bind to purified, urinary form of CD59 in ELISAs. Cell membrane expression of S1 on various cell lines always correlated with that of CD59 when examined by immunofluorescent staining. In addition, E7.1 antibody inhibited the complement regulatory function of CD59. Identification of S1 protein as CD59 has increased the scope of the AL cell system by enabling analysis of intragenic mutations, and multiplex PCR analysis of mutated cells is described, showing variable loss of CD59 exons.
An Improved Spectral Analysis Method for Fatigue Damage Assessment of Details in Liquid Cargo Tanks
NASA Astrophysics Data System (ADS)
Zhao, Peng-yuan; Huang, Xiao-ping
2018-03-01
Errors will be caused in calculating the fatigue damages of details in liquid cargo tanks by using the traditional spectral analysis method which is based on linear system, for the nonlinear relationship between the dynamic stress and the ship acceleration. An improved spectral analysis method for the assessment of the fatigue damage in detail of a liquid cargo tank is proposed in this paper. Based on assumptions that the wave process can be simulated by summing the sinusoidal waves in different frequencies and the stress process can be simulated by summing the stress processes induced by these sinusoidal waves, the stress power spectral density (PSD) is calculated by expanding the stress processes induced by the sinusoidal waves into Fourier series and adding the amplitudes of each harmonic component with the same frequency. This analysis method can take the nonlinear relationship into consideration and the fatigue damage is then calculated based on the PSD of stress. Take an independent tank in an LNG carrier for example, the accuracy of the improved spectral analysis method is proved much better than that of the traditional spectral analysis method by comparing the calculated damage results with the results calculated by the time domain method. The proposed spectral analysis method is more accurate in calculating the fatigue damages in detail of ship liquid cargo tanks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sterjovski, Jasminka; Churchill, Melissa J.; Roche, Michael
2011-02-20
CD4-binding site (CD4bs) alterations in gp120 contribute to different pathophysiological phenotypes of CCR5-using (R5) HIV-1 strains, but the potential structural basis is unknown. Here, we characterized functionally diverse R5 envelope (Env) clones (n = 16) to elucidate potential structural alterations within the gp120 CD4bs that influence Env function. Initially, we showed that the magnitude of gp120-CD4-binding correlates with increased fusogenicity and reduced CD4 dependence. Analysis of three-dimensional gp120 structural models revealed two CD4bs variants, D279 and N362, that were associated with reduced CD4 dependence. Further structural analysis showed that a wider aperture of the predicted CD4bs cavity, as constrained bymore » the inner-most atoms at the gp120 V1V2 stem and the V5 loop, was associated with amino acid alterations within V5 and correlated with increased gp120-CD4 binding and increased fusogenicity. Our results provide evidence that the gp120 V5 loop may alter CD4bs conformation and contribute to increased gp120-CD4 interactions and Env fusogenicity.« less
The CD4/CD8 ratio is associated with coronary artery disease (CAD) in elderly Chinese patients.
Gao, Pan; Rong, Hong-Hui; Lu, Ting; Tang, Gang; Si, Liang-Yi; Lederer, James A; Xiong, Wei
2017-01-01
The aim of this study was to investigate the relationship between number of circulating T cells and coronary artery disease (CAD) in an elderly Chinese population. A total of 295 elderly inpatients (age≥60) were included in this cross-sectional study. Their clinical and biochemical characteristics were recorded. Patients were divided to two groups: control patients and CAD patients. The risk factors of CAD were explored by binary logistic regression analysis. Compared with control patients, the ratio of CD4 to CD8 T cells was significantly increased in CAD patients. There was no difference in the number of CD3, CD4, and CD8 T cells between the two groups. Multiple logistic regression analysis showed that CAD was independently associated with age, gender, body mass index (BMI), systolic blood pressure (SBP), chronic heart failure (CHF) and the CD4/CD8 ratio. In addition, after adjusting for different clinical parameters (including gender, age, CHF, hypertension, arrhythmia, SBP, and BMI), the risk of CAD was significantly increased in patients with a CD4/CD8 ratio>1.5. There was a strong and independent association between the ratio of CD4/CD8 and CAD in elderly Chinese population. Copyright © 2016. Published by Elsevier B.V.
Age-dependent changes of serum soluble CD30 concentration in children.
Chrul, Slawomir; Polakowska, Ewa
2011-08-01
CD30 was originally described as a marker on Reed-Sternberg cells in Hodgkin lymphoma. The extracellular portion of CD30 is proteolytically cleaved from CD30+ cells, to produce a soluble form of the molecule (sCD30) detectable in serum. Measurement of sCD30 concentration in serum has been suggested to be a potential tool in monitoring of inflammatory status in variety of diseases. Several investigators reported the relevance for sCD30 as a predictive marker for allograft rejection following organ transplantation. The aim of the study was to verify whether sCD30 serum concentrations may be affected by an age in healthy children. Heparinized venous blood was taken from 78 healthy children. For the analysis of sCD30 levels, the commercially available sCD30 ELISA was used. The sCD30 was detected in all serum samples and concentrations ranged from 6.75 to 68.07ng/mL. The statistical analysis of all individuals showed that sCD30 concentration was significantly age depended (r=-0.618, p<0.0001). When sCD30 concentrations were analyzed in regard to gender, no significant differences were identified in age subgroups. © 2011 John Wiley & Sons A/S.
NASA Technical Reports Server (NTRS)
1995-01-01
The Interactive Data Language (IDL), developed by Research Systems, Inc., is a tool for scientists to investigate their data without having to write a custom program for each study. IDL is based on the Mariners Mars spectral Editor (MMED) developed for studies from NASA's Mars spacecraft flights. The company has also developed Environment for Visualizing Images (ENVI), an image processing system for easily analyzing remotely sensed data written in IDL. The Visible Human CD, another Research Systems product, is the first complete digital reference of photographic images for exploring human anatomy.
Menéndez-López, Nuria; Valimaña-Traverso, Jesús; Castro-Puyana, María; Salgado, Antonio; García, María Ángeles; Marina, María Luisa
2017-05-10
Two analytical methodologies were developed by CE enabling the enantiomeric separation of colchicine, an antiuremic drug commercialized as pure enantiomer. Succinyl-γ-CD and Sulfated-γ-CD were selected as chiral selectors after a screening with different anionic CDs. Under the optimized conditions, chiral resolutions of 5.6 in 12min and 3.2 in 8min were obtained for colchicine with Succinyl-γ-CD and Sulfated-γ-CD, respectively. An opposite enantiomeric migration order was observed with these two CDs being S-colchicine the first-migrating enantiomer with Succinyl-γ-CD and the second-migrating enantiomer with Sulfated-γ-CD. H NMR experiments showed a 1:1 stoichiometry for the enantiomer-CD complexes in both cases. However, the apparent and averaged equilibrium constants for the enantiomer-CD complexes could be calculated only for Succinyl-γ-CD. The developed methods were applied to the analysis of pharmaceutical formulations but only the use of Succinyl-γ-CD enabled to detect a 0.1% of enantiomeric impurity in colchicine formulations. Copyright © 2017 Elsevier B.V. All rights reserved.
Lu, XiaoCheng; Tang, Linjun; Li, Kai; Zheng, JinYu; Zhao, Penglai; Tao, Yi; Li, Li-Xin
2014-01-01
Polymorphisms in NKX2-3 gene have been inconsistently associated with Crohn's disease (CD) and ulcerative colitis (UC). To generate large-scale evidence on whether NKX2-3 polymorphisms are associated with CD or UC susceptibility we have conducted a meta-analysis of 17 studies involving 17329 patients and 18029 controls. A significantly increased CD or UC risk was observed in persons carrying a G allele at rs10883365 polymorphism (A/G) compared with those with a A allele. (OR = 1.226, 95%CI: 1.177–1.277 and OR = 1.274, 95%CI: 1.175–1.382 respectively). In the subgroup analysis, a significantly increased CD risk was found in both Europeans and Asians. For rs11190140 polymorphism (C/T) and CD risk, the risk estimate for the allele contrast was OR = 1.201 (1.136–1.269). This meta-analysis provided a robust result that persons with a G or T allele may have a moderately increased risk of CD, and suggested that rs10883365 polymorphism was also a candidate gene polymorphism for UC susceptibility. PMID:24473197
Velagapudi, Poonam; Turagam, Mohit; Kolte, Dhaval; Khera, Sahil; Hyder, Omar; Gordon, Paul; Aronow, Herbert D; Leopold, Jane; Abbott, J Dawn
2018-06-05
Previous studies have demonstrated that intramyocardial human CD34+ cells may relieve symptoms and improve clinical outcomes in chronic refractory angina unresponsive to optimal medical therapy or not amenable to revascularization. We performed a meta-analysis of randomized controlled trials (RCTs) to evaluate the impact of human CD34+ cells compared with placebo in chronic refractory angina. Primary efficacy outcomes in our analysis were angina frequency and exercise time. Primary safety outcomes included major adverse cardiovascular events such as myocardial infarction (MI), stroke and death. Three eligible randomized trials including 269 patients (placebo = 90, CD34+ = 179) were included. Dose of auto-CD34+ cells ranged from 5 × 10 4 to 5 × 10 5 cells/kg. Follow-up ranged from 6 to 24 months. In a pooled analysis, administration of CD34+ cells decreased the risk of all-cause mortality [OR 0.24, 95% CI (0.08-0.73), p = 0.01], reduced angina frequency [mean difference -2.91, 95% CI (-4.57 to -1.25), p = 0.0006] and improved exercise time [mean difference 58.62 s, 95% CI (21.19 to 96.06), p = 0.02] compared with control group. However, there was no significant difference in the risk of myocardial infarction (MI) and stroke between groups. In a meta-analysis, intra-myocardial CD34+ cell therapy was superior to placebo in improving risk of all - cause mortality, angina frequency with an increase in exercise time, without a significant increase in adverse events. This analysis supports further trials of CD34+ cell therapy for ischemic heart disease. Copyright © 2018 Elsevier Inc. All rights reserved.
sCD44 overexpression increases intraocular pressure and aqueous outflow resistance
Giovingo, Michael; Nolan, Michael; McCarty, Ryan; Pang, Iok-Hou; Clark, Abbot F.; Beverley, Rachel M.; Schwartz, Steven; Stamer, W. Daniel; Walker, Loyal; Grybauskas, Algis; Skuran, Kevin; Kuprys, Paulius V.; Yue, Beatrice Y.J.T.
2013-01-01
Purpose CD44 plays major roles in multiple physiologic processes. The ectodomain concentration of the CD44 receptor, soluble CD44 (sCD44), is significantly increased in the aqueous humor of primary open-angle glaucoma (POAG). The purpose of this study was to determine if adenoviral constructs of CD44 and isolated 32-kDa sCD44 change intraocular pressure (IOP) in vivo and aqueous outflow resistance in vitro. Methods Adenoviral constructs of human standard CD44 (Ad-CD44S), soluble CD44 (Ad-sCD44), and empty viral cDNA were injected into the vitreous of BALB/cJ mice, followed by serial IOP measurements. Overexpression of CD44S and sCD44 was verified in vitro by enzyme-linked immunosorbent assay (ELISA) and western blot analysis. Anterior segments of porcine eyes were perfused with the isolated sCD44. sCD44-treated human trabecular meshwork (TM) cells and microdissected porcine TM were examined by confocal microscopy and Optiprep density gradient with western blot analysis to determine changes in lipid raft components. Results Intravitreous injection of adenoviral constructs with either Ad-CD44S or Ad-sCD44 vectors caused prolonged ocular hypertension in mice. Eight days after vector injection, Ad-CD44S significantly elevated IOP to 28.3±1.2 mmHg (mean±SEM, n=8; p<0.001); Ad-sCD44 increased IOP to 18.5±2.6 mmHg (n=8; p<0.01), whereas the IOP of uninjected eyes was 12.7±0.2 mmHg (n=16). The IOP elevation lasted more than 50 days. Topical administration of a γ-secretase inhibitor normalized Ad-sCD44-induced elevated IOP. sCD44 levels were significantly elevated in the aqueous humor of Ad-CD44S and Ad-sCD44 eyes versus contralateral uninjected eyes (p<0.01). Anterior segment perfusion of isolated 32-kDa sCD44 significantly decreased aqueous outflow rates. Co-administration of isolated sCD44 and CD44 neutralizing antibody or of γ-secretase inhibitor significantly enhanced flow rates. sCD44-treated human TM cells displayed cross-linked actin network formation. Optiprep density gradient and western blot analysis of human TM cells treated with sCD44 showed decreased annexin 2 expression and increased phosphorylated annexin 2 and caveolin 1 expression. Conclusions Our data suggest that sCD44 increases outflow resistance in vivo and in vitro. Viral overexpression of both CD44S and sCD44 is sufficient to cause ocular hypertension. Infusion of sCD44 in porcine anterior segment eyes significantly decreased flow rates. Notably, sCD44 enhanced cross-linked actin network formation. The elevated sCD44 levels seen in POAG aqueous humor may play an important causative role in POAG pathogenesis. PMID:24194636
Zhang, Feng; Wang, Xin; Yin, Daixia; Peng, Bo; Tan, Changyin; Liu, Yunguo; Tan, Xiaofei; Wu, Shixue
2015-04-15
This study investigated the efficiency and mechanisms of Cd removal by biochar pyrolyzed from water hyacinth (BC) at 250-550 °C. BC450 out-performed the other BCs at varying Cd concentrations and can remove nearly 100% Cd from aqueous solution within 1 h at initial Cd ≤ 50 mg l(-1). The process of Cd sorption by BC450 followed the pseudo-second order kinetics with the equilibrium being achieved after 24 h with initial Cd ranging from 100 to 500 mg l(-1). The maximum Cd sorption capacity of BC450 was estimated to be 70.3 mg g(-1) based on Langmuir model, which is prominent among a range of low-cost sorbents. Based on the balance analysis between cations released and Cd sorbed onto BC450 in combination with SEM-EDX and XPS data, ion-exchange followed by surface complexation is proposed as the dominant mechanism responsible for Cd immobilization by BC450. In parallel, XRD analysis also suggested the formation of insoluble Cd minerals (CdCO3, Cd3P2, Cd3(PO4)2 and K4CdCl6) from either (co)-precipitation or ion exchange. Results from this study highlighted that the conversion of water hyacinth into biochar is a promising method to achieve effective Cd immobilization and improved management of this highly problematic invasive species. Copyright © 2015 Elsevier Ltd. All rights reserved.
Generation of Affibody ligands binding interleukin-2 receptor alpha/CD25.
Grönwall, Caroline; Snelders, Eveline; Palm, Anna Jarelöv; Eriksson, Fredrik; Herne, Nina; Ståhl, Stefan
2008-06-01
Affibody molecules specific for human IL-2Ralpha, the IL-2 (interleukin-2) receptor alpha subunit, also known as CD25, were selected by phage-display technology from a combinatorial protein library based on the 58-residue Protein A-derived Z domain. The IL-2R system plays a major role in T-cell activation and the regulation of cellular immune responses. Moreover, CD25 has been found to be overexpressed in organ rejections, a number of autoimmune diseases and T-cell malignancies. The phage-display selection using Fc-fused target protein generated 16 unique Affibody molecules targeting CD25. The two most promising binders were characterized in more detail using biosensor analysis and demonstrated strong and selective binding to CD25. Kinetic biosensor analysis revealed that the two monomeric Affibody molecules bound to CD25 with apparent affinities of 130 and 240 nM respectively. The Affibody molecules were, on biosensor analysis, found to compete for the same binding site as the natural ligand IL-2 and the IL-2 blocking monoclonal antibody 2A3. Hence the Affibody molecules were assumed to have an overlapping binding site with IL-2 and antibodies targeting the IL-2 blocking Tac epitope (for example, the monoclonal antibodies Daclizumab and Basiliximab, both of which have been approved for therapeutic use). Furthermore, immunofluorescence microscopy and flow-cytometric analysis of CD25-expressing cells demonstrated that the selected Affibody molecules bound to CD4+ CD25+ PMBCs (peripheral-blood mononuclear cells), the IL-2-dependent cell line NK92 and phytohaemagglutinin-activated PMBCs. The potential use of the CD25-binding Affibody molecules as targeting agents for medical imaging and for therapeutic applications is discussed.
NASA Astrophysics Data System (ADS)
Coccini, Teresa; Fabbri, Marco; Roda, Elisa; Grazia Sacco, Maria; Manzo, Luigi; Gribaldo, Laura
2011-07-01
Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl2 (400 μg/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil™ T700 Degussa) with average pore size of 20 nm and surface area of 240 m2/g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4×44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.
Structural and Spectroscopic Studies of Sm3+/CdS Nanocrystallites in Sol-Gel TiO2-ZrO2 Matrix
NASA Astrophysics Data System (ADS)
Karthika, S.; Prathibha, Vasudevan; Ann, Mary K. A.; Viji, Vidyadharan; Biju, P. R.; Unnikrishnan, N. V.
2014-02-01
A sol-gel method was used to prepare titania-zirconia matrices doped with Sm3+/CdS nanocrystallites. The structural properties of the matrices were characterized using transmission electron microscopy (TEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA), and Fourier-transform infrared spectroscopy studies. The thermal stability of the material was determined by TGA/DTA analysis. The absorption spectrum shows the characteristic peaks of the Sm3+ ions and the absorption peak corresponding to the CdS nanocrystallites. The optical bandgap and size of the CdS nanoparticles were calculated from the absorption spectrum. From TEM, the interplanar distance ( d) was estimated to be 3.533 Å, which matches with the (1 0 0) plane of bulk CdS. The measurements yield a nanocrystallite size of around 7.8 nm. The optical absorption and emission spectra confirmed the formation of CdS nanoparticles along with samarium ions in the titania-zirconia matrices. The fluorescence intensity of the samarium ions was found to be greatly enhanced by codoping with CdS nanocrystallites.
Li, Xiaoping; Zhao, Haojie; Gu, Jianchun; Zheng, Leizhen
2015-01-01
CD133 is one of the most commonly used markers of pancreatic cancer stem cells (CSCs), which are characterized by their ability for self-renewal and tumorigenicity. Although the expression of CD133 has been reported to correlate with poor prognosis of PDAC in most literatures, some controversies still exist. In this study, we aimed to investigate the correlation between CD133 expression and prognosis and clinicopathological features in PDAC. A search in the Medline, EMBASE and Chinese CNKI (China National Knowledge Infrastructure) database (up to 1 March 2015) was performed using the following keywords pancreatic cancer, CD133, AC133, prominin-1 etc. Data from eligible studies were extracted and included into meta-analysis using a random effects model. Outcomes included overall survival and various clinicopathological features. We performed a final analysis of 723 patients from 11 evaluable studies for prognostic value and 687 patients from 12 evaluable studies for clinicopathological features. Our study shows that the pooled hazard ratio (HR) of overexpression CD133 for overall survival in PDAC was 0.58 (95% confidence interval (CI): 0.49-0.67) by univariate analysis and 0.73 (95% CI: 0.52-1.03) by multivariate analysis. With respect to clinicopathological features, CD133 overexpression by immunohistochemistry (IHC) method was closely correlated with clinical TNM stage (TNM stage III+IV, OR=0.32, 95% CI: 0.19-0.54), tumor differentiation (poor differentiation, OR=0.56, 95% CI: 0.37-0.83), and lymph node metastasis (N1, 3.15, 95% CI: 1.56-6.36) in patients with PDAC. Our meta-analysis results suggest that CD133 is an efficient prognostic factor in PDAC. Overexpression of CD133 was significantly associated with clinical TNM stage, tumor differentiation and lymph node metastasis.
Optical biopsy fiber-based fluorescence spectroscopy instrumentation
NASA Astrophysics Data System (ADS)
Katz, Alvin; Ganesan, Singaravelu; Yang, Yuanlong; Tang, Gui C.; Budansky, Yury; Celmer, Edward J.; Savage, Howard E.; Schantz, Stimson P.; Alfano, Robert R.
1996-04-01
Native fluorescence spectroscopy of biomolecules has emerged as a new modality to the medical community in characterizing the various physiological conditions of tissues. In the past several years, many groups have been working to introduce the spectroscopic methods to diagnose cancer. Researchers have successfully used native fluorescence to distinguish cancerous from normal tissue samples in rat and human tissue. We have developed three generations of instruments, called the CD-scan, CD-ratiometer and CD-map, to allow the medical community to use optics for diagnosing tissue. Using ultraviolet excitation and emission spectral measurements on both normal and cancerous tissue of the breast, gynecology, colon, and aerodigestive tract can be separated. For example, from emission intensities at 340 nm to 440 nm (300 nm excitation), a statistically consistent difference between malignant tissue and normal or benign tissue is observed. In order to utilize optical biopsy techniques in a clinical setting, the CD-scan instrument was developed, which allows for rapid and reliable in-vitro and in-vivo florescence measurements of the aerodigestive tract with high accuracy. The instrumentation employs high sensitivity detection techniques which allows for lamp excitation, small diameter optical fiber probes; the higher spatial resolution afforded by the small diameter probes can increase the ability to detect smaller tumors. The fiber optic probes allow for usage in the aerodigestive tract, cervix and colon. Needle based fiber probes have been developed for in-vivo detection of breast cancer.
II-VI Narrow-Bandgap Semiconductors for Optoelectronics
NASA Astrophysics Data System (ADS)
Baker, Ian
The field of narrow-gap II-VI materials is dominated by the compound semiconductor mercury cadmium telluride, (Hg1-x Cd x Te or MCT), which supports a large industry in infrared detectors, cameras and infrared systems. It is probably true to say that HgCdTe is the third most studied semiconductor after silicon and gallium arsenide. Hg1-x Cd x Te is the material most widely used in high-performance infrared detectors at present. By changing the composition x the spectral response of the detector can be made to cover the range from 1 μm to beyond 17 μm. The advantages of this system arise from a number of features, notably: close lattice matching, high optical absorption coefficient, low carrier generation rate, high electron mobility and readily available doping techniques. These advantages mean that very sensitive infrared detectors can be produced at relatively high operating temperatures. Hg1-x Cd x Te multilayers can be readily grown in vapor-phase epitaxial processes. This provides the device engineer with complex doping and composition profiles that can be used to further enhance the electro-optic performance, leading to low-cost, large-area detectors in the future. The main purpose of this chapter is to describe the applications, device physics and technology of II-VI narrow-bandgap devices, focusing on HgCdTe but also including Hg1-x Mn x Te and Hg1-x Zn x Te. It concludes with a review of the research and development programs into third-generation infrared detector technology (so-called GEN III detectors) being performed in centers around the world.
Polarized Infrared Absorption of Dipole Centers in Cadmium Halide and PbI2 Crystals
NASA Astrophysics Data System (ADS)
Terakami, Mitsushi; Nakagawa, Hideyuki
2004-03-01
Polarized infrared (IR) absorption measurements on CN- or OH- centers in cadmium halide and PbI2 crystals were carried out at 6 K with a high spectral resolution of 0.025 cm-1 at 2000 cm-1 by using a FTIR spectrometer. Several sharp absorption lines with widths less than 0.1 cm-1 are observed in the energy region of the stretching vibration, i.e. 2000 to 2250 cm-1 for CN- and 2500 to 4500 cm-1 for OH-. These lines are classified into several groups attributed to (1) an isolated center simply substituted for a halogen ion, (2) an interstitial center located between the cadmium and halogen ion sheets and (3) a coupled center with an anion vacancy or a host metal ion. Almost all of the dipole axes (bond axes) of the CN- ions doped in MI2 (M = Cd or Pb) are parallel to the crystal c-axes, while those of the isolated and coupled CN- centers in CdX2 (X = Cl or Br) lean away from the direction of the c-axis. The most OH- ions doped in CdX2 (X = Cl, Br or I) and PbI2 are arranged in the halogen-ion planes with their dipole axes parallel to the crystal c-axes. The first overtone yields values of χe and ωeχe for CN- and OH- in CdX2 and PbI2. These values explain well the isotope shift of the main stretching band in CdX2 and PbI2.
1986-09-01
source of the module/system. Source options are; battery, gas, cartridge, valve , and miscellaneous costs. NAMELIST OPERAT is used to compile the...hardware costs allocated to transportation for packing. TF1 = Initial transportation factor. WEIGHT = Shipping weight of total system. XSUM = System float...CD(6,I)+CD(9,I). . AROC(7,I) - Replenishment spares by year. CD(4,I) - Valve replacement cost by year. CD(5,I) = Cartridge replacement cost by year
2008-03-01
Appendix 82 MatLab© Cd Calculator Routine FORTRAN© Subroutine of the Variable Cd Model ii ABBREVIATIONS & ACRONYMS Cd...Figure 29. Overview Flowchart of Benét Labs Recoil Analysis Code Figure 30. Overview Flowchart of Recoil Brake Subroutine Figure 31...Detail Flowchart of Recoil Pressure/Force Calculations Figure 32. Detail Flowchart of Variable Cd Subroutine Figure 33. Simulated Brake
Transcriptional profiling of CD31(+) cells isolated from murine embryonic stem cells.
Mariappan, Devi; Winkler, Johannes; Chen, Shuhua; Schulz, Herbert; Hescheler, Jürgen; Sachinidis, Agapios
2009-02-01
Identification of genes involved in endothelial differentiation is of great interest for the understanding of the cellular and molecular mechanisms involved in the development of new blood vessels. Mouse embryonic stem (mES) cells serve as a potential source of endothelial cells for transcriptomic analysis. We isolated endothelial cells from 8-days old embryoid bodies by immuno-magnetic separation using platelet endothelial cell adhesion molecule-1 (also known as CD31) expressed on both early and mature endothelial cells. CD31(+) cells exhibit endothelial-like behavior by being able to incorporate DiI-labeled acetylated low-density lipoprotein as well as form tubular structures on matrigel. Quantitative and semi-quantitative PCR analysis further demonstrated the increased expression of endothelial transcripts. To ascertain the specific transcriptomic identity of the CD31(+) cells, large-scale microarray analysis was carried out. Comparative bioinformatic analysis reveals an enrichment of the gene ontology categories angiogenesis, blood vessel morphogenesis, vasculogenesis and blood coagulation in the CD31(+) cell population. Based on the transcriptomic signatures of the CD31(+) cells, we conclude that this ES cell-derived population contains endothelial-like cells expressing a mesodermal marker BMP2 and possess an angiogenic potential. The transcriptomic characterization of CD31(+) cells enables an in vitro functional genomic model to identify genes required for angiogenesis.
McIntire, Patrick J; Irshaid, Lina; Liu, Yifang; Chen, Zhengming; Menken, Faith; Nowak, Eugene; Shin, Sandra J; Ginter, Paula S
2018-05-07
CD8 + tumor-infiltrating lymphocytes (TILs) have emerged as a prognostic indicator in triple-negative breast cancer (TNBC). There is debate surrounding the prognostic value of hot spots for CD8 + TIL enumeration. We compared hot spot versus whole-tumor CD8 + TIL enumeration in prognosticating TNBC using immunohistochemistry on whole tissue sections and quantification by digital image analysis (Halo imaging analysis software; Indica Labs, Corrales, NM). A wide range of clinically relevant hot spot sizes was evaluated. CD8 + TIL enumeration was independently statistically significant for all hot spot sizes and whole-tumor annotations for disease-free survival by multivariate analysis. A 10× objective (2.2 mm diameter) hot spot was found to correlate significantly with overall survival (P = .04), while the remaining hot spots and whole-tumor CD8 + TIL enumeration did not (P > .05). Statistical significance was not demonstrated when comparing between hot spots and whole-tumor annotations, as the groups had overlapping confidence intervals. CD8 + TIL hot spot enumeration is equivalent to whole-tumor enumeration for prognostication in TNBC and may serve as a good alternative methodology in future studies and clinical practice. Copyright © 2018 Elsevier Inc. All rights reserved.
Toward blue emission in ZnO based LED
NASA Astrophysics Data System (ADS)
Viana, Bruno; Pauporté, Thierry; Lupan, Oleg; Le Bahers, Tangui; Ciofini, Ilaria
2012-03-01
The bandgap engineering of ZnO nanowires by doping is of great importance for tunable light emitting diode (LED) applications. We present a combined experimental and computational study of ZnO doping with Cd or Cu atoms in the nanomaterial. Zn1-xTMxO (TM=Cu, Cd) nanowires have been epitaxially grown on magnesium-doped p-GaN by electrochemical deposition. The Zn1-xTMxO/p-GaN heterojunction was integrated in a LED structure. Nanowires act as the light emitters and waveguides. At room temperature, TM-doped ZnO based LEDs exhibit low-threshold emission voltage and electroluminescence emission shifted from ultraviolet to violet-blue spectral region compared to pure ZnO LEDs. The emission wavelength can be tuned by changing the transition metal (TM) content in the ZnO nanomaterial and the shift is discussed, including insights from DFT computational investigations.
Performance of s-192 (hg,cd)te arrays.
Aldrich, N C; Beck, J D
1972-10-01
Very high performance (Hg,Cd)Te photoconductive detectors have been fabricated for use on the S-192 experiment, which is a multispectral scanner being built by Honeywell for the NASA Manned Space Center's Skylab. The S-192 will scan the earth from Skylab and record data in twelve near ir spectral bands and one long wavelength band. The near ir bands range from 0.4 micro to 2.35 micro. At 87 K with a 90 degrees FOV, we have consistently produced arrays with specific detectivities at 2.35 micro close to or greater than 8 x 10(11) cm Hz((1/2))/W and with detective time constants less than 1 microsec. These detectors demonstrate good uniformity in performance across an array. State-of-the-art fabrication techniques have been used to make detectors with good definition that are 5-10 micro thick with 25-micro spacing between elements.
Dynamics of the bleaching of tail states in CdS1- x Se x mixed crystals
NASA Astrophysics Data System (ADS)
Breitkopf, T.; Kalt, H.; Klingshirn, C.; Reznitsky, A.
1996-06-01
The kinetics of excitons localized by statistic potential fluctuations have been studied in CdS 1-xSex ternary alloys under quasi-stationary excitation conditions and have been time resolved after picosecond-pulse excitation. In luminescence experiments we observe the filling of the band tail with rising excitation intensity. The reduction of carrier density with time by recombination leads to a red shift of the luminescence band after picosecond-pulse excitation. Bleaching of absorption of the localized states is found in pump-probe experiments. Its dynamics depend on the localization depth of the excitons and on the pump-pulse energy. Using higher excitation intensities, we observe stimulated emission in luminescence, correlated with significant changes in the behavior of the absorption bleaching. The possible origin of the stimulated emission situated in the spectral region of localized states is discussed.
NASA Astrophysics Data System (ADS)
Yamaoka, H.; Yamamoto, Y.; Schwier, E. F.; Honda, F.; Zekko, Y.; Ohta, Y.; Lin, J.-F.; Nakatake, M.; Iwasawa, H.; Arita, M.; Shimada, K.; Hiraoka, N.; Ishii, H.; Tsuei, K.-D.; Mizuki, J.
2015-12-01
Pressure- and temperature-induced changes in the Ce valence and c -f hybridization of the Ce115 superconductors have been studied systematically. Resonant x-ray-emission spectroscopy indicated that the increase of the Ce valence with pressure was significant for CeCoIn5, and moderate for CeIr (In0.925Cd0.075)5 . We found no abrupt change of the Ce valence in the Kondo regime for CeIr (In0.925Cd0.075)5 , which suggests that valence fluctuations are unlikely to mediate the superconductivity in this material. X-ray-diffraction results were consistent with the pressure-induced change in the Ce valence. High-resolution photoelectron spectroscopy revealed a temperature-dependent reduction of the spectral intensity at the Fermi level, indicating enhanced c -f hybridization on cooling.
BOREAS TE-23 Canopy Architecture and Spectral Data from Hemispherical Photographs
NASA Technical Reports Server (NTRS)
Rich, Paul M.; Hall, Forrest G. (Editor); Papagno, Andrea (Editor)
2000-01-01
The Boreal Ecosystem-Atmospheric Study (BOREAS) TE-23 (Terrestrial Ecology) team collected hemispherical photographs in support of its efforts to characterize and interpret information on estimates of canopy architecture and radiative transfer properties for most BOREAS study sites. Various Old Aspen (OA), Old Black Spruce (OBS), Old Jack Pine (OJP), Young Jack Pine (YJP), and Young Aspen (YA) sites in the boreal forest were measured from May to August 1994. The hemispherical photographs were used to derive values of leaf area index (LAI), leaf angle, gap fraction, and clumping index. This documentation describes these derived values. The derived data are stored in tabular ASCII files. The hemispherical photographs are stored in the original set of 42 CD-ROMs that were supplied by TE-23. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).
Alagöz, Cengiz; Pekel, Gökhan; Alagöz, Neşe; Sayın, Nihat; Yüksel, Kemal; Yıldırım, Yusuf; Yazıcı, Ahmet Taylan
2016-12-01
Our aim was to evaluate the alterations of subfoveal choroidal thickness (SFCT), photoreceptor layer thickness (PRT), and retinal vessel diameter in the dark and light adaptation. Twenty-four eyes of 24 healthy volunteers (12 males, 12 females) were included in this cross-sectional and observational study. The SFCT, PRT, retinal arteriole, and venule caliber measurements were performed with spectral domain optical coherence tomography in the dark (0.0 cd/m 2 ) and under light (80 cd/m 2 ) adapted conditions. The mean age of the participants was 30.4 ± 4.4 years (range: 22-42). The SFCT increased statistically significantly in dark adaptation (p < 0.001), then returned to baseline values following light adaptation. The PRT, retinal arteriole, and venule caliber measurements were similar in the dark and light (p > 0.05). While SFCT increased, PRT, and retinal vessel diameter did not change following transition from light to dark.
NASA Technical Reports Server (NTRS)
Rutter, James; Libonate, Scott; Denley, Brian; Gurnee, Mark N.; Robillard, Gene
1996-01-01
The Atmospheric Infrared Sounder (AIRS) is a key facility instrument in the NASA Earth Observing System (EOS) program, being implemented to obtain comprehensive long-term measurements of earth processes affecting global change. The instrument performs passive IR remote sensing using a high resolution grating spectrometer with a wide spectral coverage (3.7 - 15.4 m) directing radiation onto a hybrid HgCdTe IRFPA operating at 58K in a vacuum package cooled to 155K. The hybrid HgCdTe FPA consists of twelve modules, 10 with multiplexed photovoltaic detectors and two with individually leaded out photoconductive detectors. The complex FPA has a large optical footprint, 53 mm x 66 mm, and receives energy dispersed from the grating through a precision filter assembly containing 17 narrow band filters. The backside illuminated PV detector arrays are fabricated from P-on-n double layer LPE grown heterojunction detectors in a bilinear format of 50 m x 100 m detectors, with from 232 to 420 detectors per module. For the MWIR bands four PV modules cover the 3.7 m to 8.22 m region. Low detector capacitance and low noise preamplifiers in the ROIC are key to achieving high sensitivities in these bands. Uniform quantum efficiencies and detectivities exceeding 3E13 cm-rtHz/W have been achieved. The LWIR region is covered by six PV modules spanning 8.8 m to 13.75 m. High detector resistance and very low ROIC preamplifier input noise are key to achieving high sensitivity. A detectivity exceeding 2E11 cm-rtHz/W has been achieved at the longest wavelength. Two additional PC modules cover the longest spectral bands out to 15.4 m. This high performance multispectral focal plane has been built and integrated with the dewar assembly, and is currently being integrated with the complete AIRS sensor.
NASA Astrophysics Data System (ADS)
Silverglate, Peter R.; Fort, Dennis E.
2004-01-01
CRISM (Compact Reconnaissance Imaging Spectrometer for Mars) is a hyperspectral imager that will be launched on the MRO (Mars Reconnaissance Orbiter) in August 2005. The MRO will circle Mars in a polar orbit at a nominal altitude of 325 km. The CRISM spectral range spans the ultraviolet (UV) to the mid-wave infrared (MWIR), 400 nm to 4050 nm. The instrument utilizes a Ritchey-Chretien telescope with a 2.06º field of view (FOV) to focus light on the entrance slit of a dual spectrometer. Within the spectrometer light is split by a dichroic into VNIR (visible-near infrared) (λ <= 1.05 μm) and IR (infrared) (λ >= 1.05 μm) beams. Each beam is directed into a separate modified Offner spectrometer that focuses a spectrally dispersed image of the slit onto a two dimensional focal plane (FP). The IR FP is a 640 x 480 HgCdTe area array; the VNIR FP is a 640 x 480 silicon photodiode area array. The spectral image is contiguously sampled with a 6.55 nm spectral spacing and an instantaneous field of view of 60 μradians. The orbital motion of the MRO pushbroom scans the spectrometer slit across the Martian surface, allowing the planet to be mapped in 558 spectral bands. There are four major mapping modes: A quick initial multi-spectral mapping of a major portion of the Martian surface in 59 selected spectral bands at a spatial resolution of 600 μradians (10:1 binning); an extended multi-spectral mapping of the entire Martian surface in 59 selected spectral bands at a spatial resolution of 300 μradians (5:1 binning); a high resolution Target Mode, performing hyperspectral mapping of selected targets of interest at full spatial and spectral resolution; and an atmospheric Emission Phase Function (EPF) mode for atmospheric study and correction at full spectral resolution at a spatial resolution of 300 μradians (5:1 binning). The instrument is gimbaled to allow scanning over +/-60° for the EPF and Target modes. The scanning also permits orbital motion compensation, enabling longer integration times and consequently higher signal-to-noise ratios for selected areas on the Martian surface in Target Mode.