21 CFR 864.6160 - Manual blood cell counting device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Manual blood cell counting device. 864.6160...
21 CFR 864.6160 - Manual blood cell counting device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Manual blood cell counting device. 864.6160...
21 CFR 864.6160 - Manual blood cell counting device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Manual blood cell counting device. 864.6160...
21 CFR 864.6160 - Manual blood cell counting device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Manual blood cell counting device. 864.6160...
21 CFR 864.6160 - Manual blood cell counting device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160... blood cell counting device. (a) Identification. A manual blood cell counting device is a device used to count red blood cells, white blood cells, or blood platelets. (b) Classification. Class I (general...
NASA Technical Reports Server (NTRS)
Tai, Yu-Chong (Inventor); Kasdan, Harvey L. (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor)
2016-01-01
Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.
NASA Technical Reports Server (NTRS)
Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey (Inventor); Tai, Yu-Chong (Inventor)
2015-01-01
Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.
NASA Technical Reports Server (NTRS)
Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)
2017-01-01
Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.
21 CFR 864.8185 - Calibrator for red cell and white cell counting.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for red cell and white cell counting... Calibrator for red cell and white cell counting. (a) Identification. A calibrator for red cell and white cell counting is a device that resembles red or white blood cells and that is used to set instruments intended...
21 CFR 864.8185 - Calibrator for red cell and white cell counting.
Code of Federal Regulations, 2014 CFR
2014-04-01
... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibrator for red cell and white cell counting...
21 CFR 864.8185 - Calibrator for red cell and white cell counting.
Code of Federal Regulations, 2012 CFR
2012-04-01
... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibrator for red cell and white cell counting...
21 CFR 864.8185 - Calibrator for red cell and white cell counting.
Code of Federal Regulations, 2011 CFR
2011-04-01
... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibrator for red cell and white cell counting...
21 CFR 864.8185 - Calibrator for red cell and white cell counting.
Code of Federal Regulations, 2013 CFR
2013-04-01
... counting is a device that resembles red or white blood cells and that is used to set instruments intended to count red cells, white cells, or both. It is a suspension of particles or cells whose size, shape... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibrator for red cell and white cell counting...
Identification and validation of nebulized aerosol devices for sputum induction
Davidson, Warren J; Dennis, John; The, Stephanie; Litoski, Belinda; Pieron, Cora; Leigh, Richard
2014-01-01
Induced sputum cell count measurement has proven reliability for evaluating airway inflammation in patients with asthma and other airway diseases. Although the use of nebulizer devices for sputum induction is commonplace, they are generally labelled as single-patient devices by the manufacturer and, therefore, cannot be used for multiple patients in large clinical sputum induction programs due to infect ion-control requirements. Accordingly, this study investigated the aerosol characteristics of alternative devices that could be used in such programs. BACKGROUND: Induced sputum cell counts are a noninvasive and reliable method for evaluating the presence, type and degree of airway inflammation in patients with asthma. Currently, standard nebulizer devices used for sputum induction in multiple patients are labelled as single-patient devices by the manufacturer, which conflicts with infection prevention and control requirements. As such, these devices cannot feasibly be used in a clinical sputum induction program. Therefore, there is a need to identify alternative nebulizer devices that are either disposable or labelled for multi-patient use. OBJECTIVE: To apply validated rigorous, scientific testing methods to identify and validate commercially available nebulizer devices appropriate for use in a clinical sputum induction program. METHODS: Measurement of nebulized aerosol output and size for the selected nebulizer designs followed robust International Organization for Standardization methods. Sputum induction using two of these nebulizers was successfully performed on 10 healthy adult subjects. The cytotechnologist performing sputum cell counts was blinded to the type of nebulizer used. RESULTS: The studied nebulizers had variable aerosol outputs. The AeroNeb Solo (Aerogen, Ireland), Omron NE-U17 (Omron, Japan) and EASYneb II (Flaem Nuova, Italy) systems were found to have similar measurements of aerosol size. There was no significant difference in induced sputum cell results between the AeroNeb Solo and EASYneb II devices. DISCUSSION: There is a need for rigorous, scientific evaluation of nebulizer devices for clinical applications, including sputum induction, for measurement of cell counts. CONCLUSION: The present study was the most comprehensive analysis of different nebulizer devices for sputum induction to measure cell counts, and provides a framework for appropriate evaluation of nebulizer devices for induced sputum testing. PMID:24288700
Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H
2016-12-01
We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.
A multi-channel clogging-resistant lab-on-a-chip cell counter and analyzer
NASA Astrophysics Data System (ADS)
Dai, Jie; Chiu, Yu-Jui; Lian, Ian; Wu, Tsung-Feng; Yang, Kecheng; Lo, Yu-Hwa
2016-02-01
Early signs of diseases can be revealed from cell detection in biofluids, such as detection of white blood cells (WBCs) in the peritoneal fluid for peritonitis. A lab-on-a-chip microfluidic device offers an attractive platform for such applications because of its small size, low cost, and ease of use provided the device can meet the performance requirements which many existing LoC devices fail to satisfy. We report an integrated microfluidic device capable of accurately counting low concentration of white blood cells in peritoneal fluid at 150 μl min-1 to offer an accurate (<3% error) and fast (~10 min/run) WBC count. Utilizing the self-regulating hydrodynamic properties and a unique architecture in the design, the device can achieve higher flow rate (500-1000 μl min-1), continuous running for over 5 h without clogging, as well as excellent signal quality for unambiguous WBC count and WBC classification for certain diseases. These properties make the device a promising candidate for point-of-care applications.
Atac, M.; McKay, T.A.
1998-04-21
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.
Atac, Muzaffer; McKay, Timothy A.
1998-01-01
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.
NASA Technical Reports Server (NTRS)
Li, Yue (Inventor); Bruck, Jehoshua (Inventor)
2018-01-01
A data device includes a memory having a plurality of memory cells configured to store data values in accordance with a predetermined rank modulation scheme that is optional and a memory controller that receives a current error count from an error decoder of the data device for one or more data operations of the flash memory device and selects an operating mode for data scrubbing in accordance with the received error count and a program cycles count.
Gunetti, Monica; Castiglia, Sara; Rustichelli, Deborah; Mareschi, Katia; Sanavio, Fiorella; Muraro, Michela; Signorino, Elena; Castello, Laura; Ferrero, Ivana; Fagioli, Franca
2012-05-31
The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests' accuracy, precision, repeatability, linearity and range. As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution).
2012-01-01
Background The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests’ accuracy, precision, repeatability, linearity and range. Methods As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. Results All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Conclusions Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution). PMID:22650233
Even-Or, Ehud; Di Mola, Maria; Ali, Muhammad; Courtney, Sarah; McDougall, Elizabeth; Alexander, Sarah; Schechter, Tal; Whitlock, James A; Licht, Christoph; Krueger, Joerg
2017-06-01
The manufacturing of cellular products for immunotherapy, such as chimeric antigen receptor T cells, requires successful collection of mononuclear cells. Collections from children with high-risk leukemia present a challenge, especially because the established COBE Spectra apheresis device is being replaced by the novel Spectra Optia device (Optia) in many institutions. Published experience for mononuclear cell collections in children with Optia is lacking. Our aim was to compare the two collection devices and describe modified settings on the Optia to optimize mononuclear cell collections. As a quality initiative, we retrospectively collected and compared data from mononuclear cell collections on both devices. Collected data included patient's clinical characteristics; collection parameters, including precollection lymphocyte/CD3 counts, total blood volumes processed, runtimes, and side effects (including complete blood count and electrolyte changes); and product characteristics, including volumes and cell counts. Collection efficiencies and collection ratios were calculated. Twenty-six mononuclear cell collections were performed on 20 pediatric patients: 11 with COBE and 15 with Optia. Adequate mononuclear cell products were successfully collected with a single procedure from all patients except one, with mean calculated mononuclear cell collection efficiency that was significantly higher from Optia collections compared with COBE collections (57.9 ± 4.6% vs 40.3 ± 6.2%, respectively; p = 0.04). CD3-positive yields were comparable on both machines (p = 0.34) with significantly smaller blood volumes processed on Optia. Collected products had larger volumes on Optia. No significant side effects attributed to the procedure were noted. Mononuclear cell apheresis using the Optia device in children is more efficient and is as safe as that with the COBE device. © 2017 AABB.
NASA Astrophysics Data System (ADS)
Yun, Hoyoung; Bang, Hyunwoo; Lee, Won Gu; Lim, Hyunchang; Park, Junha; Lee, Joonmo; Riaz, Asif; Cho, Keunchang; Chung, Chanil; Han, Dong-Chul; Chang, Jun Keun
2007-12-01
Although CD4+ T-cells are an important target of HIV detection, there have been still major problems in making a diagnosis and monitoring in the third world and the region with few medical facilities. Then, it is necessary to use portable diagnosis devices at low cost when you put an enumeration of CD4+ T-cells. In general, the counting of CD4 below 200cells/uL makes it necessary to initiate antiretroviral treatment in adults (over 13 years old). However, lymphocyte subsets (including CD4 counts) of infants and young children are higher than those of adults. This fact shows the percentage of CD4+ T-cells of blood subsets, i.e., CD4/CD45%, CD4/CD8% or CD4/CD3% means a more reliable indicator of HIV infection than absolute counts in children. To know the percentage of CD4+ T-cell by using two fluorescent dyes of different emission wavelength, at least, one laser and two PMT detectors are in general needed. Then, it is so hard to develop a portable device like a 'toaster size' because this makes such a device more complex including many peripheral modules. In this study, we developed a novel technique to control the intensity of fluorescent dye-doped silica nanoparticles. I synthesized FITC-doped silica nanoparticles conjugated CD4 antibody 10 times brighter than FITC-conjugated CD45 antibody. With the difference of intensity of two fluorescent dyes, we measured two parameters by using only a single detector and laser. Most experiments were achieved with uFACS (microfabricated fluorescence-activated cell sorter) on an inverted microscope (IX71, Olympus). In conclusion, this method enables us to discriminate the difference between CD4 and CD45 in an intensity domain simultaneously. Furthermore, this technique would make it possible develop much cheaper and smaller devices which can count the number of CD4 T-cells.
First comparative analysis concerning the plasma platelet contamination during MNC collection.
Pfeiffer, Hella; Achenbach, Susanne; Strobel, Julian; Zimmermann, Robert; Eckstein, Reinhold; Strasser, Erwin F
2017-08-01
Monocytes can be cultured into dendritic cells with addition of autologous plasma, which is highly prone to platelet contamination due to the apheresis process. Since platelets affect the maturation process of monocytes into dendritic cells and might even lead to a diminished harvest of dendritic cells, it is very important to reduce the platelet contamination. A new collection device (Spectra Optia) was analyzed, compared to two established devices (COM.TEC, Cobe Spectra) and evaluated regarding the potential generation of source plasma. Concurrent plasma collected during leukapheresis was analyzed for residual cell contamination in a prospective study with the new Spectra Optia apheresis device (n=24) and was compared with COM.TEC and Cobe Spectra data (retrospective analysis, n=72). Donor pre-donation counts of platelets were analyzed for their predictive value of contaminating PLTs in plasma harvests. The newest apheresis device showed the lowest residual platelet count of the collected concurrent plasma (median 3.50×10 9 /l) independent of pre-donation counts. The other two devices and sets had a higher platelet contamination. The contamination of the plasma with leukocytes was very low (only 2.0% were higher than 0.5×10 9 /l). This study showed a significant reduction of platelet contamination of the concurrent plasma collected with the new Spectra Optia device. This plasma product with low residual platelets and leukocytes might also be used as plasma for fractionation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cerebrovascular accidents in patients with a ventricular assist device.
Tsukui, Hiroyuki; Abla, Adib; Teuteberg, Jeffrey J; McNamara, Dennis M; Mathier, Michael A; Cadaret, Linda M; Kormos, Robert L
2007-07-01
A cerebrovascular accident is a devastating adverse event in a patient with a ventricular assist device. The goal was to clarify the risk factors for cerebrovascular accident. Prospectively collected data, including medical history, ventricular assist device type, white blood cell count, thrombelastogram, and infection, were reviewed retrospectively in 124 patients. Thirty-one patients (25%) had 48 cerebrovascular accidents. The mean ventricular assist device support period was 228 and 89 days in patients with and without cerebrovascular accidents, respectively (P < .0001). Sixty-six percent of cerebrovascular accidents occurred within 4 months after implantation. Actuarial freedom from cerebrovascular accident at 6 months was 75%, 64%, 63%, and 33% with the HeartMate device (Thoratec Corp, Pleasanton, Calif), Thoratec biventricular ventricular assist device (Thoratec Corp), Thoratec left ventricular assist device (Thoratec), and Novacor device (WorldHeart, Oakland, Calif), respectively. Twenty cerebrovascular accidents (42%) occurred in patients with infections. The mean white blood cell count at the cerebrovascular accident was greater than the normal range in patients with infection (12,900/mm3) and without infection (9500/mm3). The mean maximum amplitude of the thrombelastogram in the presence of infection (63.6 mm) was higher than that in the absence of infection (60.7 mm) (P = .0309). The risk of cerebrovascular accident increases with a longer ventricular assist device support period. Infection may activate platelet function and predispose the patient to a cerebrovascular accident. An elevation of the white blood cell count may also exacerbate the risk of cerebrovascular accident even in patients without infection. Selection of device type, prevention of infection, and meticulous control of anticoagulation are key to preventing cerebrovascular accident.
Differential white cell count by centrifugal microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.
We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less
NASA Technical Reports Server (NTRS)
Edmonds, Jessica
2015-01-01
Aurora Flight Sciences, in partnership with Draper Laboratory, has developed a miniaturized system to count white blood cells in microgravity environments. The system uses MEMS technology to simultaneously count total white blood cells, the five white blood cell differential subgroups, and various lymphocyte subtypes. The OILWBCS-MEMS detection technology works by immobilizing an array of white blood cell-specific antibodies on small, gold-coated membranes. When blood flows across the membranes, specific cells' surface protein antigens bind to their corresponding antibodies. This binding can be measured and correlated to cell counts. In Phase I, the partners demonstrated surface chemistry sensitivity and specificity for total white blood cells and two lymphocyte subtypes. In Phase II, a functional prototype demonstrated end-to-end operation. This rugged, miniaturized device requires minimal blood sample preparation and will be useful for both space flight and terrestrial applications.
Signal focusing through active transport
NASA Astrophysics Data System (ADS)
Godec, Aljaž; Metzler, Ralf
2015-07-01
The accuracy of molecular signaling in biological cells and novel diagnostic devices is ultimately limited by the counting noise floor imposed by the thermal diffusion. Motivated by the fact that messenger RNA and vesicle-engulfed signaling molecules transiently bind to molecular motors and are actively transported in biological cells, we show here that the random active delivery of signaling particles to within a typical diffusion distance to the receptor generically reduces the correlation time of the counting noise. Considering a variety of signaling particle sizes from mRNA to vesicles and cell sizes from prokaryotic to eukaryotic cells, we show that the conditions for active focusing—faster and more precise signaling—are indeed compatible with observations in living cells. Our results improve the understanding of molecular cellular signaling and novel diagnostic devices.
A Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples
NASA Astrophysics Data System (ADS)
Ma, Wei-Yuan; Hsiung, Lo-Chang; Wang, Chen-Ho; Chiang, Chi-Ling; Lin, Ching-Hung; Huang, Chiun-Sheng; Wo, Andrew M.
2015-04-01
Drug-based treatments are the most widely used interventions for cancer management. Personalized drug response profiling remains inherently challenging with low cell count harvested from tumour sample. We present a 96well-formatted microfluidic plate with built-in micro-gap that preserves up to 99.2% of cells during multiple assay/wash operation and only 9,000 cells needed for a single reagent test (i.e. 1,000 cells per test spot x 3 selected concentration x triplication), enabling drug screening and compatibility with conventional automated workstations. Results with MCF7 and MDA-MB-231 cell lines showed that no statistical significance was found in dose-response between the device and conventional 96-well plate control. Primary tumour samples from breast cancer patients tested in the device also showed good IC50 prediction. With drug screening of primary cancer cells must consider a wide range of scenarios, e.g. suspended/attached cell types and rare/abundant cell availability, the device enables high throughput screening even for suspended cells with low cell count since the signature microfluidic cell-trapping feature ensures cell preservation in a multiple solution exchange protocol.
Comparison of Six Different Silicones In Vitro for Application as Glaucoma Drainage Device
Windhövel, Claudia; Harder, Lisa; Bach, Jan-Peter; Teske, Michael; Grabow, Niels; Eickner, Thomas; Chichkov, Boris; Nolte, Ingo
2018-01-01
Silicones are widely used in medical applications. In ophthalmology, glaucoma drainage devices are utilized if conservative therapies are not applicable or have failed. Long-term success of these devices is limited by failure to control intraocular pressure due to fibrous encapsulation. Therefore, different medical approved silicones were tested in vitro for cell adhesion, cell proliferation and viability of human Sclera (hSF) and human Tenon fibroblasts (hTF). The silicones were analysed also depending on the sample preparation according to the manufacturer’s instructions. The surface quality was characterized with environmental scanning electron microscope (ESEM) and water contact angle measurements. All silicones showed homogeneous smooth and hydrophobic surfaces. Cell adhesion was significantly reduced on all silicones compared to the negative control. Proliferation index and cell viability were not influenced much. For development of a new glaucoma drainage device, the silicones Silbione LSR 4330 and Silbione LSR 4350, in this study, with low cell counts for hTF and low proliferation indices for hSF, and silicone Silastic MDX4-4210, with low cell counts for hSF and low proliferation indices for hTF, have shown the best results in vitro. Due to the high cell adhesion shown on Silicone LSR 40, 40,026, this material is unsuitable. PMID:29495462
An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor
NASA Astrophysics Data System (ADS)
Staderini, Enrico Maria; Castellano, Alfredo
1986-02-01
An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2. On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation.
Autebert, Julien; Coudert, Benoit; Champ, Jérôme; Saias, Laure; Guneri, Ezgi Tulukcuoglu; Lebofsky, Ronald; Bidard, François-Clément; Pierga, Jean-Yves; Farace, Françoise; Descroix, Stéphanie; Malaquin, Laurent; Viovy, Jean-Louis
2015-05-07
A new generation of the Ephesia cell capture technology optimized for CTC capture and genetic analysis is presented, characterized in depth and compared with the CellSearch system as a reference. This technology uses magnetic particles bearing tumour-cell specific EpCAM antibodies, self-assembled in a regular array in a microfluidic flow cell. 48,000 high aspect-ratio columns are generated using a magnetic field in a high throughput (>3 ml h(-1)) device and act as sieves to specifically capture the cells of interest through antibody-antigen interactions. Using this device optimized for CTC capture and analysis, we demonstrated the capture of epithelial cells with capture efficiency above 90% for concentrations as low as a few cells per ml. We showed the high specificity of capture with only 0.26% of non-epithelial cells captured for concentrations above 10 million cells per ml. We investigated the capture behavior of cells in the device, and correlated the cell attachment rate with the EpCAM expression on the cell membranes for six different cell lines. We developed and characterized a two-step blood processing method to allow for rapid processing of 10 ml blood tubes in less than 4 hours, and showed a capture rate of 70% for as low as 25 cells spiked in 10 ml blood tubes, with less than 100 contaminating hematopoietic cells. Using this device and procedure, we validated our system on patient samples using an automated cell immunostaining procedure and a semi-automated cell counting method. Our device captured CTCs in 75% of metastatic prostate cancer patients and 80% of metastatic breast cancer patients, and showed similar or better results than the CellSearch device in 10 out of 13 samples. Finally, we demonstrated the possibility of detecting cancer-related PIK3CA gene mutation in 20 cells captured in the chip with a good correlation between the cell count and the quantitation value Cq of the post-capture qPCR.
21 CFR 864.5200 - Automated cell counter.
Code of Federal Regulations, 2014 CFR
2014-04-01
....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...
21 CFR 864.5200 - Automated cell counter.
Code of Federal Regulations, 2011 CFR
2011-04-01
....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...
21 CFR 864.5200 - Automated cell counter.
Code of Federal Regulations, 2012 CFR
2012-04-01
....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...
21 CFR 864.5200 - Automated cell counter.
Code of Federal Regulations, 2013 CFR
2013-04-01
....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the patient's peripheral blood (blood circulating in one of the body's extremities, such as the arm). These...
21 CFR 864.5200 - Automated cell counter.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell counter. 864.5200 Section 864.5200....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the...
Dielectrophoretic columnar focusing device
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Conrad D; Galambos, Paul C; Derzon, Mark S
2010-05-11
A dielectrophoretic columnar focusing device uses interdigitated microelectrodes to provide a spatially non-uniform electric field in a fluid that generates a dipole within particles in the fluid. The electric field causes the particles to either be attracted to or repelled from regions where the electric field gradient is large, depending on whether the particles are more or less polarizable than the fluid. The particles can thereby be forced into well defined stable paths along the interdigitated microelectrodes. The device can be used for flow cytometry, particle control, and other process applications, including cell counting or other types of particle counting,more » and for separations in material control.« less
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Handheld Diagnostic Device Delivers Quick Medical Readings
NASA Technical Reports Server (NTRS)
2014-01-01
To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.
Rapid white blood cell detection for peritonitis diagnosis
NASA Astrophysics Data System (ADS)
Wu, Tsung-Feng; Mei, Zhe; Chiu, Yu-Jui; Cho, Sung Hwan; Lo, Yu-Hwa
2013-03-01
A point-of-care and home-care lab-on-a-chip (LoC) system that integrates a microfluidic spiral device as a concentrator with an optical-coding device as a cell enumerator is demonstrated. The LoC system enumerates white blood cells from dialysis effluent of patients receiving peritoneal dialysis. The preliminary results show that the white blood cell counts from our system agree well with the results from commercial flow cytometers. The LoC system can potentially bring significant benefits to end stage renal disease (ESRD) patients that are on peritoneal dialysis (PD).
Feasibility of a novel one-stop ISET device to capture CTCs and its clinical application
Zheng, Liang; Zhi, Xuan; Cheng, Boran; Chen, Yuanyuan; Zhang, Chunxiao; Shi, Dongdong; Song, Haibin; Cai, Congli; Zhou, Pengfei; Xiong, Bin
2017-01-01
Introduction Circulating tumor cells (CTCs) play a crucial role in cancer metastasis. In this study, we introduced a novel isolation method by size of epithelial tumor cells (ISET) device with automatic isolation and staining procedure, named one-stop ISET (osISET) and validated its feasibility to capture CTCs from cancer patients. Moreover, we aim to investigate the correlation between clinicopathologic features and CTCs in colorectal cancer (CRC) in order to explore its clinical application. Results The capture efficiency ranged from 80.3% to 88% with tumor cells spiked into medium while 67% to 78.3% with tumor cells spiked into healthy donors’ blood. In detection blood samples of 72 CRC patients, CTCs and clusters of circulating tumor cells (CTC-clusters) were detected with a positive rate of 52.8% (38/72) and 18.1% (13/72) respectively. Moreover, CTC positive rate was associated with factors of lymphatic or venous invasion, tumor depth, lymph node metastasis and TNM stage in CRC patients (p < 0.01). Lymphocyte count and neutrophil to lymphocyte ratio (NLR) were significantly different between CTC positive and negative groups (p < 0.01). Materials and Methods The capture efficiency of the device was tested by spiking cancer cells (MCF-7, A549, SW480, Hela) into medium or blood samples of healthy donors. Blood samples of 72 CRC patients were detected by osISET device. The clinicopathologic characteristics of 72 CRC patients were collected and the association with CTC positive rate or CTC count were analyzed. Conclusions Our osISET device was feasible to capture and identify CTCs and CTC-clusters from cancer patients. In addition, our device holds a potential for application in cancer management. PMID:27935872
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tahara, Makiko; Department of Gastrointestinal Surgery, Jichi Medical University, Shimotsuke, Tochigi; Inoue, Takeshi
2013-05-17
Highlights: •Chemo-sensitivity to SN-38 was assayed by the automated cell counter. •Colon cancer cell line, HCT116 cells were more sensitive to SN-38 than HT29 cells. •Increase of cell size reflects G2/M arrest. •Appearance of small particles indicates cell apoptosis. -- Abstract: In vitro assessment of chemosensitivity are important for experiments evaluating cancer therapies. The Scepter 2.0 cell counter, an automated handheld device based on the Coulter principle of impedance-based particle detection, enables the accurate discrimination of cell populations according to cell size and volume. In this study, the effects of SN-38, the active metabolite of irinotecan, on the colon cancermore » cell lines HCT116 and HT29 were evaluated using this device. The cell count data obtained with the Scepter counter were compared with those obtained with the {sup 3}H-thymidine uptake assay, which has been used to measure cell proliferation in many previous studies. In addition, we examined whether the changes in the size distributions of these cells reflected alterations in the frequency of cell cycle arrest and/or apoptosis induced by SN-38 treatment. In our experiments using the Scepter 2.0 cell counter, the cell counts were demonstrated to be accurate and reproducible measure and alterations of cell diameter reflected G2/M cell cycle arrest and apoptosis. Our data show that easy-to-use cell counting tools can be utilized to evaluate the cell-killing effects of novel treatments on cancer cells in vitro.« less
Exclusion-Based Capture and Enumeration of CD4+ T Cells from Whole Blood for Low-Resource Settings.
Howard, Alexander L; Pezzi, Hannah M; Beebe, David J; Berry, Scott M
2014-06-01
In developing countries, demand exists for a cost-effective method to evaluate human immunodeficiency virus patients' CD4(+) T-helper cell count. The TH (CD4) cell count is the current marker used to identify when an HIV patient has progressed to acquired immunodeficiency syndrome, which results when the immune system can no longer prevent certain opportunistic infections. A system to perform TH count that obviates the use of costly flow cytometry will enable physicians to more closely follow patients' disease progression and response to therapy in areas where such advanced equipment is unavailable. Our system of two serially-operated immiscible phase exclusion-based cell isolations coupled with a rapid fluorescent readout enables exclusion-based isolation and accurate counting of T-helper cells at lower cost and from a smaller volume of blood than previous methods. TH cell isolation via immiscible filtration assisted by surface tension (IFAST) compares well against the established Dynal T4 Quant Kit and is sensitive at CD4 counts representative of immunocompromised patients (less than 200 TH cells per microliter of blood). Our technique retains use of open, simple-to-operate devices that enable IFAST as a high-throughput, automatable sample preparation method, improving throughput over previous low-resource methods. © 2013 Society for Laboratory Automation and Screening.
NASA Astrophysics Data System (ADS)
Tsai, Wen-Sy; Chen, Jinn-Shiun; Shao, Hung-Jen; Wu, Jen-Chia; Lai-Ming, Jr.; Lu, Si-Hong; Hung, Tsung-Fu; Chiu, Yen-Chi; You, Jeng-Fu; Hsieh, Pao-Shiu; Yeh, Chien-Yuh; Hung, Hsin-Yuan; Chiang, Sum-Fu; Lin, Geng-Ping; Tang, Reiping; Chang, Ying-Chih
2016-04-01
Enumeration of circulating tumor cells (CTCs) has been proven as a prognostic marker for metastatic colorectal cancer (m-CRC) patients. However, the currently available techniques for capturing and enumerating CTCs lack of required sensitivity to be applicable as a prognostic marker for non-metastatic patients as CTCs are even more rare. We have developed a microfluidic device utilizing antibody-conjugated non-fouling coating to eliminate nonspecific binding and to promote the multivalent binding of target cells. We then established the correlation of CTC counts and neoplasm progression through applying this platform to capture and enumerate CTCs in 2 mL of peripheral blood from healthy (n = 27), benign (n = 21), non-metastatic (n = 95), and m-CRC (n = 15) patients. The results showed that the CTC counts progressed from 0, 1, 5, to 36. Importantly, after 2-year follow-up on the non-metastatic CRC patients, we found that those who had ≥5 CTCs were 8 times more likely to develop distant metastasis within one year after curable surgery than those who had <5. In conclusion, by employing a sensitive device, CTC counts show good correlation with colorectal neoplasm, thus CTC may be as a simple, independent prognostic marker for the non-metastatic CRC patients who are at high risk of early recurrence.
Godish, Diana; Godish, Thad
2008-02-01
This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.
A portable optical reader and wall projector towards enumeration of bio-conjugated beads or cells
McArdle, Niamh A.; Kendlin, Jane L.; O’Connell, Triona M.; Ducrée, Jens
2017-01-01
Measurement of the height of a packed column of cells or beads, which can be direclty related to the number of cells or beads present in a chamber, is an important step in a number of diagnostic assays. For example, haematocrit measurements may rapidly identify anemia or polycthemia. Recently, user-friendly and cost-efficient Lab-on-a-Chip devices have been developed towards isolating and counting cell sub-populations for diagnostic purposes. In this work, we present a low-cost optical module for estimating the filling level of packed magnetic beads within a Lab-on-a-Chip device. The module is compatible with a previously introduced, disposable microfluidic chip for rapid determination of CD4+ cell counts. The device is a simple optical microscope module is manufactured by 3D printing. An objective lens directly interrogates the height of packed beads which are efficiently isolated on the finger-actuated chip. Optionally, an inexpensive, battery-powered Light Emitting Diode may project a shadow of the microfluidic chip at approximately 50-fold magnification onto a nearby surface. The reader is calibrated with the filling levels of known concentrations of paramagnetic beads within the finger actuated chip. Results in direct and projector mode are compared to measurements from a conventional, inverted white-light microscope. All three read-out methods indicate a maximum variation of 6.5% between methods. PMID:29267367
[Automated analyser of organ cultured corneal endothelial mosaic].
Gain, P; Thuret, G; Chiquet, C; Gavet, Y; Turc, P H; Théillère, C; Acquart, S; Le Petit, J C; Maugery, J; Campos, L
2002-05-01
Until now, organ-cultured corneal endothelial mosaic has been assessed in France by cell counting using a calibrated graticule, or by drawing cells on a computerized image. The former method is unsatisfactory because it is characterized by a lack of objective evaluation of the cell surface and hexagonality and it requires an experienced technician. The latter method is time-consuming and requires careful attention. We aimed to make an efficient, fast and easy to use, automated digital analyzer of video images of the corneal endothelium. The hardware included a PC Pentium III ((R)) 800 MHz-Ram 256, a Data Translation 3155 acquisition card, a Sony SC 75 CE CCD camera, and a 22-inch screen. Special functions for automated cell boundary determination consisted of Plug-in programs included in the ImageTool software. Calibration was performed using a calibrated micrometer. Cell densities of 40 organ-cultured corneas measured by both manual and automated counting were compared using parametric tests (Student's t test for paired variables and the Pearson correlation coefficient). All steps were considered more ergonomic i.e., endothelial image capture, image selection, thresholding of multiple areas of interest, automated cell count, automated detection of errors in cell boundary drawing, presentation of the results in an HTML file including the number of counted cells, cell density, coefficient of variation of cell area, cell surface histogram and cell hexagonality. The device was efficient because the global process lasted on average 7 minutes and did not require an experienced technician. The correlation between cell densities obtained with both methods was high (r=+0.84, p<0.001). The results showed an under-estimation using manual counting (2191+/-322 vs. 2273+/-457 cell/mm(2), p=0.046), compared with the automated method. Our automated endothelial cell analyzer is efficient and gives reliable results quickly and easily. A multicentric validation would allow us to standardize cell counts among cornea banks in our country.
NASA Astrophysics Data System (ADS)
Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua; Jiang, Hao; Street, Robert A.; Lu, Jeng Ping
2014-03-01
The thin-film semiconductor processing methods that enabled creation of inexpensive liquid crystal displays based on amorphous silicon transistors for cell phones and televisions, as well as desktop, laptop and mobile computers, also facilitated the development of devices that have become ubiquitous in medical x-ray imaging environments. These devices, called active matrix flat-panel imagers (AMFPIs), measure the integrated signal generated by incident X rays and offer detection areas as large as ~43×43 cm2. In recent years, there has been growing interest in medical x-ray imagers that record information from X ray photons on an individual basis. However, such photon counting devices have generally been based on crystalline silicon, a material not inherently suited to the cost-effective manufacture of monolithic devices of a size comparable to that of AMFPIs. Motivated by these considerations, we have developed an initial set of small area prototype arrays using thin-film processing methods and polycrystalline silicon transistors. These prototypes were developed in the spirit of exploring the possibility of creating large area arrays offering single photon counting capabilities and, to our knowledge, are the first photon counting arrays fabricated using thin film techniques. In this paper, the architecture of the prototype pixels is presented and considerations that influenced the design of the pixel circuits, including amplifier noise, TFT performance variations, and minimum feature size, are discussed.
Point-of-care blood eosinophil count in a severe asthma clinic setting.
Heffler, Enrico; Terranova, Giovanni; Chessari, Carlo; Frazzetto, Valentina; Crimi, Claudia; Fichera, Silvia; Picardi, Giuseppe; Nicolosi, Giuliana; Porto, Morena; Intravaia, Rossella; Crimi, Nunzio
2017-07-01
One of the main severe asthma phenotypes is severe eosinophilic or eosinophilic refractory asthma for which novel biologic agents are emerging as therapeutic options. In this context, blood eosinophil counts are one of the most reliable biomarkers. To evaluate the performance of a point-of-care peripheral blood counter in a patients with severe asthma. The blood eosinophil counts of 76 patients with severe asthma were evaluated by point-of-care and standard analyzers. A significant correlation between blood eosinophils assessed by the 2 devices was found (R 2 = 0.854, P < .001); similar correlations were found also for white blood cells, neutrophils, and lymphocytes. The point-of-care device had the ability to predict blood eosinophil cutoffs used to select patients for biologic treatments for severe eosinophilic asthma and the ELEN index, a composite score useful to predict sputum eosinophilia. The results of our study contribute to the validation of a point-of-care device to assess blood eosinophils and open the possibility of using this device for the management of severe asthma management. Copyright © 2017 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Novel microfluidic device for the continuous separation of cancer cells using dielectrophoresis.
Alazzam, Anas; Mathew, Bobby; Alhammadi, Falah
2017-03-01
We describe the design, microfabrication, and testing of a microfluidic device for the separation of cancer cells based on dielectrophoresis. Cancer cells, specifically green fluorescent protein-labeled MDA-MB-231, are successfully separated from a heterogeneous mixture of the same and normal blood cells. MDA-MB-231 cancer cells are separated with an accuracy that enables precise detection and counting of circulating tumor cells present among normal blood cells. The separation is performed using a set of planar interdigitated transducer electrodes that are deposited on the surface of a glass wafer and slightly protrude into the separation microchannel at one side. The device includes two parts, namely, a glass wafer and polydimethylsiloxane element. The device is fabricated using standard microfabrication techniques. All experiments are conducted with low conductivity sucrose-dextrose isotonic medium. The variation in response between MDA-MB-231 cancer cells and normal cells to a certain band of alternating-current frequencies is used for continuous separation of cells. The fabrication of the microfluidic device, preparation of cells and medium, and flow conditions are detailed. The proposed microdevice can be used to detect and separate malignant cells from heterogeneous mixture of cells for the purpose of early screening for cancer. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fragmented red cells reference range for the Sysmex XN®-series of automated blood cell counters.
Lesesve, J-F; Speyer, E; Perol, J-P
2015-10-01
Fragmented red cells (FRCs) are a new parameter determined automatically by the latest generation of blood cell counters. FRC counts may be of interest as they may reflect schistocyte counts measured on a stained peripheral blood smear observed under the microscope. However, FRC counts depend on the technical procedure used to detect them so that reference ranges are device dependent. The XN-9000® is one of the latest models from the Sysmex series of analysers. We aimed to establish a reference range for FRCs based on 1366 normal patient samples. The mean ± SD was 0.14 ± 0.35% and the median was 0% (95% confidence interval of the mean: 0.12-0.16%). We observed that the percentage of red blood cells with <17 pg of haemoglobin content (Hypo-He) was correlated to an FRC increase and that flagged results relating to red blood cells, reticulocytes or platelets might have presented with artefactually increased FRCs. The FRCs reference range (healthy subjects) should be useful for laboratory staff for selecting which blood smears to check optically. © 2015 John Wiley & Sons Ltd.
Imaging System and Method for Biomedical Analysis
2013-03-11
biological particles and items of interest. Broadly, Padmanabhan et al. utilize the diffraction of a laser light source in flow cytometry to count...spread of light from multiple LED devices over the entire sample surface. Preferably, light source 308 projects a full spectrum white light. Light...for example, red blood cells, white blood cells (which may include lymphocytes which are relatively large and easily detectable), T-helper cells
Reversible assembly of magnetized particles: Application to water-borne pathogen enumeration
NASA Astrophysics Data System (ADS)
Ramadan, Qasem
2009-12-01
Reversible assembly of magnetized particles and cells has been proposed and implemented. The approach is based on magnetized particles or magnetically labeled cell immobilization in an array of individual particle/cell for optical counting. The device has been tested for few types of magnetic particles and one water-borne pathogen: Giardia Lamblia. An individual particle immobilization efficiency of 92% was achieved.
Viles, C L; Sieracki, M E
1992-01-01
Accurate measurement of the biomass and size distribution of picoplankton cells (0.2 to 2.0 microns) is paramount in characterizing their contribution to the oceanic food web and global biogeochemical cycling. Image-analyzed fluorescence microscopy, usually based on video camera technology, allows detailed measurements of individual cells to be taken. The application of an imaging system employing a cooled, slow-scan charge-coupled device (CCD) camera to automated counting and sizing of individual picoplankton cells from natural marine samples is described. A slow-scan CCD-based camera was compared to a video camera and was superior for detecting and sizing very small, dim particles such as fluorochrome-stained bacteria. Several edge detection methods for accurately measuring picoplankton cells were evaluated. Standard fluorescent microspheres and a Sargasso Sea surface water picoplankton population were used in the evaluation. Global thresholding was inappropriate for these samples. Methods used previously in image analysis of nanoplankton cells (2 to 20 microns) also did not work well with the smaller picoplankton cells. A method combining an edge detector and an adaptive edge strength operator worked best for rapidly generating accurate cell sizes. A complete sample analysis of more than 1,000 cells averages about 50 min and yields size, shape, and fluorescence data for each cell. With this system, the entire size range of picoplankton can be counted and measured. Images PMID:1610183
Handheld 2-channel impedimetric cell counting system with embedded real-time processing
NASA Astrophysics Data System (ADS)
Rottigni, A.; Carminati, M.; Ferrari, G.; Vahey, M. D.; Voldman, J.; Sampietro, M.
2011-05-01
Lab-on-a-chip systems have been attracting a growing attention for the perspective of miniaturization and portability of bio-chemical assays. Here we present a the design and characterization of a miniaturized, USB-powered, self-contained, 2-channel instrument for impedance sensing, suitable for label-free tracking and real-time detection of cells flowing in microfluidic channels. This original circuit features a signal generator based on a direct digital synthesizer, a transimpedance amplifier, an integrated square-wave lock-in coupled to a Σ▵ ADC converter, and a digital processing platform. Real-time automatic peak detection on two channels is implemented in a FPGA. System functionality has been tested with an electronic resistance modulator to simulate 1% impedance variation produced by cells, reaching a time resolution of 50μs (enabling a count rate of 2000 events/s) with an applied voltage as low as 200mV. Biological experiments have been carried out counting yeast cells. Statistical analysis of events is in agreement with the expected amplitude and time distributions. 2-channel yeast counting has been performed with concomitant dielectrophoretic cell separation, showing that this novel and ultra compact sensing system, thanks to the selectivity of the lock-in detector, is compatible with other AC electrical fields applied to the device.
Low latency counter event indication
Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY
2008-09-16
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
Low latency counter event indication
Gara, Alan G.; Salapura, Valentina
2010-08-24
A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.
Space and power efficient hybrid counters array
Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY
2009-05-12
A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.
Space and power efficient hybrid counters array
Gara, Alan G.; Salapura, Valentina
2010-03-30
A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.
A Micro Fluorescent Activated Cell Sorter for Astrobiology Applications
NASA Technical Reports Server (NTRS)
Platt, Donald W.; Hoover, Richard B.
2009-01-01
A micro-scale Fluorescent Activated Cell Sorter (microFACS) for astrobiology applications is under development. This device is designed to have a footprint of 7 cm x 7 cm x 4 cm and allow live-dead counts and sorting of cells that have fluorescent characteristics from staining. The FACS system takes advantage of microfluidics to create a cell sorter that can fit in the palm of the hand. A micron-scale channel allows cells to pass by a blue diode which causes emission of marker-expressed cells which are detected by a filtered photodetector. A small microcontroller then counts cells and operates high speed valves to select which chamber the cell is collected in (a collection chamber or a waste chamber). Cells with the expressed characteristic will be collected in the collection chamber. This system has been built and is currently being tested. We are also designing a system with integrated MEMS-based pumps and valves for a small and compact unit to fly on small satellite-based biology experiments.
NASA Astrophysics Data System (ADS)
Pestana, Noah Benjamin
Accurate quantification of circulating cell populations is important in many areas of pre-clinical and clinical biomedical research, for example, in the study of cancer metastasis or the immune response following tissue and organ transplants. Normally this is done "ex-vivo" by drawing and purifying a small volume of blood and then analyzing it with flow cytometry, hemocytometry or microfludic devices, but the sensitivity of these techniques are poor and the process of handling samples has been shown to affect cell viability and behavior. More recently "in vivo flow cytometry" (IVFC) techniques have been developed where fluorescently-labeled cells flowing in a small blood vessel in the ear or retina are analyzed, but the sensitivity is generally poor due to the small sampling volume. To address this, our group recently developed a method known as "Diffuse Fluorescence Flow Cytometry" (DFFC) that allows detection and counting of rare circulating cells with diffuse photons, offering extremely high single cell counting sensitivity. In this thesis, an improved DFFC prototype was designed and validated. The chief improvements were three-fold, i) improved optical collection efficiency, ii) improved detection electronics, and iii) development of a method to mitigate motion artifacts during in vivo measurements. In combination, these improvements yielded an overall instrument detection sensitivity better than 1 cell/mL in vivo, which is the most sensitive IVFC system reported to date. Second, development and validation of a low-cost microfluidic device reader for analysis of ocular fluids is described. We demonstrate that this device has equivalent or better sensitivity and accuracy compared a fluorescence microscope, but at an order-of-magnitude reduced cost with simplified operation. Future improvements to both instruments are also discussed.
Villamor, N; Kirsch, A; Huhn, D; Vives-Corrons, J L; Serke, S
1996-06-01
Flow cytometrical methods have been introduced recently as an alternative to the enumeration of reticulocytes by microscopy. Two of these methods have gained widespread use in haematological practice; the multiparametric flow cytometer using thiazole orange staining (Retic-Count, FACScan) and the single-application reticulocyte counter using auramine-O staining (R-series, Sysmex). Several studies have emphasized the excellent correlations between microscopy and these techniques. The purpose of our study has been to examine the specificity of these automated devices with regard to cells classified as 'reticulocytes' and the effect that this may have on measures of reticulocyte maturity. Our results indicate that the specificity of reticulocyte measurements by both the Sysmex R-1000/-3000 and the Retic-Count system is relatively low. This is due to the presence of leucocytes amongst cells classified as reticulocytes. These leucocytes display intense staining with either dye, leading to an erroneous estimation of RMI (thiazole orange) and high fluorescence count (R-1000/-3000). This error is directly correlated with the leucocyte count. The basis for reticulocyte identification should be improved before automated estimation of reticulocyte maturation can be used in clinical practice.
Analysis system for characterisation of simple, low-cost microfluidic components
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Nxumalo, Zandile; Land, Kevin; Davies, Emlyn; Fourie, Louis; Marais, Philip; Roux, Pieter
2014-06-01
There is an inherent trade-off between cost and operational integrity of microfluidic components, especially when intended for use in point-of-care devices. We present an analysis system developed to characterise microfluidic components for performing blood cell counting, enabling the balance between function and cost to be established quantitatively. Microfluidic components for sample and reagent introduction, mixing and dispensing of fluids were investigated. A simple inlet port plugging mechanism is used to introduce and dispense a sample of blood, while a reagent is released into the microfluidic system through compression and bursting of a blister pack. Mixing and dispensing of the sample and reagent are facilitated via air actuation. For these microfluidic components to be implemented successfully, a number of aspects need to be characterised for development of an integrated point-of-care device design. The functional components were measured using a microfluidic component analysis system established in-house. Experiments were carried out to determine: 1. the force and speed requirements for sample inlet port plugging and blister pack compression and release using two linear actuators and load cells for plugging the inlet port, compressing the blister pack, and subsequently measuring the resulting forces exerted, 2. the accuracy and repeatability of total volumes of sample and reagent dispensed, and 3. the degree of mixing and dispensing uniformity of the sample and reagent for cell counting analysis. A programmable syringe pump was used for air actuation to facilitate mixing and dispensing of the sample and reagent. Two high speed cameras formed part of the analysis system and allowed for visualisation of the fluidic operations within the microfluidic device. Additional quantitative measures such as microscopy were also used to assess mixing and dilution accuracy, as well as uniformity of fluid dispensing - all of which are important requirements towards the successful implementation of a blood cell counting system.
Lenfestey, Robert W; Smith, P Brian; Moody, M Anthony; Clark, Reese H; Cotten, C Michael; Seed, Patrick C; Benjamin, Daniel K
2007-09-01
Infection is a common and potentially devastating complication following placement of ventriculoperitoneal (VP) shunts and cerebrospinal fluid (CSF) reservoirs in neonates. The goal of this study was to determine the normal ranges for cell count parameters in neonates with VP shunts and CSF reservoirs, as well as to determine the predictive value of CSF parameters as markers of infection. The authors evaluated neonates from 150 different neonatal intensive care units of the Pediatrix Medical Group who had undergone a lumbar puncture, VP shunt insertion, or CSF reservoir placement between 1997 and 2004. Data were collected from 9704 neonates with a mean birthweight of 2573 g and a mean gestational age of 35 weeks. Of these neonates, 181 had VP shunt insertions or CSF reservoir placements. In neonates with negative CSF cultures, significant differences were found between those with and without VP shunts or CSF reservoirs when comparing red blood cell (RBC) count (620/mm' compared with 155/mm3, p < 0.05), absolute eosinophil count (4/mm3 compared with 2/mm3, p < 0.001), protein levels (179 mg/dl compared with 115 mg/dl, p < 0.001), and glucose levels (27.5 mg/dl compared with 49 mg/dl, p < 0.001). No significant difference was found between white blood cell (WBC) counts in neonates with or without VP shunts who had negative CSF cultures. The sensitivity and specificity of a cutoff value of 20 WBCs/mm3 for diagnosing meningitis in neonates with positive cultures and intraventricular drainage devices were 67% and 62%, respectively. Although differences exist between CSF parameters found in neonates with or without VP shunts or CSF reservoirs, only the difference in RBC count is large enough to be clinically significant. The authors found that the utility of CSF parameters in neonates with VP shunts or CSF reservoirs was limited due to poor diagnostic sensitivity and specificity.
33 CFR 159.127 - Safety coliform count: Recirculating devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety coliform count....127 Safety coliform count: Recirculating devices. Thirty-eight of forty samples of flush fluid from a recirculating device must have less than 240 fecal coliform bacteria per 100 milliliters. These samples must be...
NASA Astrophysics Data System (ADS)
Khosravi, Farhad; Trainor, Patrick; Rai, Shesh N.; Kloecker, Goetz; Wickstrom, Eric; Panchapakesan, Balaji
2016-04-01
We demonstrate the rapid and label-free capture of breast cancer cells spiked in buffy coats using nanotube-antibody micro-arrays. Single wall carbon nanotube arrays were manufactured using photo-lithography, metal deposition, and etching techniques. Anti-epithelial cell adhesion molecule (EpCAM) antibodies were functionalized to the surface of the nanotube devices using 1-pyrene-butanoic acid succinimidyl ester functionalization method. Following functionalization, plain buffy coat and MCF7 cell spiked buffy coats were adsorbed on to the nanotube device and electrical signatures were recorded for differences in interaction between samples. A statistical classifier for the ‘liquid biopsy’ was developed to create a predictive model based on dynamic time warping to classify device electrical signals that corresponded to plain (control) or spiked buffy coats (case). In training test, the device electrical signals originating from buffy versus spiked buffy samples were classified with ˜100% sensitivity, ˜91% specificity and ˜96% accuracy. In the blinded test, the signals were classified with ˜91% sensitivity, ˜82% specificity and ˜86% accuracy. A heatmap was generated to visually capture the relationship between electrical signatures and the sample condition. Confocal microscopic analysis of devices that were classified as spiked buffy coats based on their electrical signatures confirmed the presence of cancer cells, their attachment to the device and overexpression of EpCAM receptors. The cell numbers were counted to be ˜1-17 cells per 5 μl per device suggesting single cell sensitivity in spiked buffy coats that is scalable to higher volumes using the micro-arrays.
Gulsen, Ismail; Ak, Hakan; Demir, Nihat; Sosuncu, Enver; Arslan, Mehmet
2015-01-01
Objective: The purpose of the presenting study was to determine how frequently external ventricular drainage (EVD) device should be changed in children with ventriculopertienal shunt (VPS) infection during prolonged intravenous antimicrobial therapy. Methods: In this retrospective study, 25 children with VPS infection were evaluated between January 2012 and December 2013. In these children VPS was surgically removed and appropriate antimicrobial therapy was administered according to cerebrospinal culture results. Data noted about how frequently EVD device had been changed, the number of cells on direct observation of cerebrospinal fluid (CSF), glucose and protein levels of CSF, and CSF culture results were obtained from patients’ records. Results: Total 25 children were included in the study. The median age was three months (1 and 65 months). In 44% of children, Staphylococcus epidermidis was isolated. During treatment period, EVD catheter has changed one to six times. A total of 68 EVD catheters were changed in these patients. When the duration of ventriculostomy catheter and leukocyte count in CSF were evaluated on daily basis, leukocyte count was decreased 5 units per day in children whose catheter remained less than 10 days. However, in children whose catheter remained more than 10 days leukocyte count was decreased 2.21 units per day. Conclusions: In children with VPS infection, EVD device should be changed at every 10 days for the rapid resolution of the infection. PMID:26101506
A microchip CD4 counting method for HIV monitoring in resource-poor settings.
Rodriguez, William R; Christodoulides, Nicolaos; Floriano, Pierre N; Graham, Susan; Mohanty, Sanghamitra; Dixon, Meredith; Hsiang, Mina; Peter, Trevor; Zavahir, Shabnam; Thior, Ibou; Romanovicz, Dwight; Bernard, Bruce; Goodey, Adrian P; Walker, Bruce D; McDevitt, John T
2005-07-01
More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed. Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity. Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.
NASA Astrophysics Data System (ADS)
Shih, Yeu-Farn; Huang, Nien-Tsu; Lee, Chih-Kung
2015-03-01
It is estimated that about one-third of the world's population has already been infected by tuberculosis. Mycobacterium tuberculosis, in general, can result in an active case of tuberculosis in approximately 5%-10% of those who suffer from latent tuberculosis and the chance of becoming ill is the highest within one of year of getting the disease. Although a newly developed methods called interferon gamma release assay (IGRA) can monitor CD4 cells secreted cytokine to diagnose tuberculosis (TB) condition. However, it is difficult to count total numbers of cytokine secreted CD4 cells, which make the diagnosis less accurate. Therefore, we develop a functionalized polydimethylsiloxane (PDMS) device using glutaraldehyde to capture CD4 cells. To enhance the capture efficiency, we use COMSOL simulation to optimize the arrangement of PDMS micro pillars to make cells uniformly distributed in the device. Our preliminary data showed the microfluidic configuration in a circular shape with HCP patterned micro pillars turned 30 degrees offers the highest cell capture rate.
NASA Astrophysics Data System (ADS)
1984-01-01
Calibrated in kilowatt hours per square meter, the solar counter produced by Dodge Products, Inc. provides a numerical count of the solar energy that has accumulated on a surface. Solar energy sensing, measuring and recording devices in corporate solar cell technology developed by Lewis Research Center. Customers for their various devices include architects, engineers and others engaged in construction and operation of solar energy facilities; manufacturers of solar systems or solar related products, such as glare reducing windows; and solar energy planners in federal and state government agencies.
NASA Astrophysics Data System (ADS)
Qasaimeh, Mohammad A.; Wu, Yichao C.; Bose, Suman; Menachery, Anoop; Talluri, Srikanth; Gonzalez, Gabriel; Fulciniti, Mariateresa; Karp, Jeffrey M.; Prabhala, Rao H.; Karnik, Rohit
2017-04-01
The necessity for bone marrow aspiration and the lack of highly sensitive assays to detect residual disease present challenges for effective management of multiple myeloma (MM), a plasma cell cancer. We show that a microfluidic cell capture based on CD138 antigen, which is highly expressed on plasma cells, permits quantitation of rare circulating plasma cells (CPCs) in blood and subsequent fluorescence-based assays. The microfluidic device is based on a herringbone channel design, and exhibits an estimated cell capture efficiency of ~40-70%, permitting detection of <10 CPCs/mL using 1-mL sample volumes, which is difficult using existing techniques. In bone marrow samples, the microfluidic-based plasma cell counts exhibited excellent correlation with flow cytometry analysis. In peripheral blood samples, the device detected a baseline of 2-5 CD138+ cells/mL in healthy donor blood, with significantly higher numbers in blood samples of MM patients in remission (20-24 CD138+ cells/mL), and yet higher numbers in MM patients exhibiting disease (45-184 CD138+ cells/mL). Analysis of CPCs isolated using the device was consistent with serum immunoglobulin assays that are commonly used in MM diagnostics. These results indicate the potential of CD138-based microfluidic CPC capture as a useful ‘liquid biopsy’ that may complement or partially replace bone marrow aspiration.
Philip, Joseph; Biswas, Amit Kumar; Chatterjee, Tathagata; Mallhi, Rajiv Singh
2014-01-01
To compare the Fenwal Amicus and the Fresenius COM.TEC apheresis instruments regarding donor peripheral blood parameters, operational variables of the instruments, and quality control parameters of the product obtained. We performed 100 platelet collections from 100 voluntary donors using the 2 studied devices. We measured platelet count using an automated analyzer and analyzed the activation statuses using a flow cytometer. The median time needed to perform the procedures was significantly longer with the COM.TEC. However, the product we obtained using the Amicus instrument showed higher degrees of platelet-activation. All products we obtained with both instruments had white blood cell counts of less than 5 × 10(6) per bag. We observed no statistical difference regarding collection efficiency and collection rates between the devices. Both instruments collected platelets efficiently, with minimal donor discomfort. Compared with the COM.TEC instrument, the Amicus reached the platelet target yield more quickly; however, it displayed an increase in platelet activation. Copyright© by the American Society for Clinical Pathology (ASCP).
Effects of Electromagnetic Fields on Automated Blood Cell Measurements.
Vagdatli, Eleni; Konstandinidou, Vasiliki; Adrianakis, Nikolaos; Tsikopoulos, Ioannis; Tsikopoulos, Alexios; Mitsopoulou, Kyriaki
2014-08-01
The aim of this study is to investigate whether the electromagnetic fields associated with mobile phones and/or laptops interfere with blood cell counts of hematology analyzers. Random blood samples were analyzed on an Aperture Impedance hematology analyzer. The analysis was performed in four ways: (A) without the presence of any mobile phone or portable computer in use, (B) with mobile phones in use (B1: one mobile, B4: four mobiles), (C) with portable computers (laptops) in use (C1: one laptop, C3: three laptops), and (D) with four mobile phones and three laptops in use simultaneously. The results obtained demonstrated a statistically significant decrease in neutrophil, erythrocyte, and platelet count and an increase in lymphocyte count, mean corpuscular volume, and red blood cell distribution width, notably in the B4 group. Despite this statistical significance, in clinical practice, only the red blood cell reduction could be taken into account, as the mean difference between the A and B4 group was 60,000 cells/µL. In group D, the analyzer gave odd results after 11 measurements and finally stopped working. The combined and multiple use of mobile phones and computers affects the function of hematology analyzers, leading to false results. Consequently, the use of such electronic devices must be avoided. © 2014 Society for Laboratory Automation and Screening.
Wang, Hsiang-Yu; Bhunia, Arun K; Lu, Chang
2006-12-15
Interest in electrical lysis of biological cells on a microfludic platform has increased because it allows for the rapid recovery of intracellular contents without introducing lytic agents. In this study we demonstrated a simple microfluidic flow-through device which lysed Escherichia coli cells under a continuous dc voltage. The E. coli cells had previously been modified to express green fluorescent protein (GFP). In our design, the cell lysis only happened in a defined section of a microfluidic channel due to the local field amplification by geometric modification. The geometric modification also effectively decreased the required voltage for lysis by several folds. We found that local field strength of 1000-1500 V/cm was required for nearly 100% cell death. This threshold field strength was considerably lower than the value reported in the literature, possibly due to the longer duration of the field [Lee, S.W., Tai, Y.C., 1999. Sens. Actuators A: Phys. 73, 74-79]. Cell lysis was detected by both plate count and fluorescence spectroscopy. The cell membrane was completely disintegrated in the lysis section of the microfluidic device, when the field strength was higher than 2000 V/cm. The devices were fabricated using low-cost soft lithography with channel widths considerably larger than the cell size to avoid clogging and ensure stable performance. Our tool will be ideal for high throughput processing of bacterial cells for chemical analysis of intracellular contents such as DNA and proteins. The application of continuous dc voltage greatly simplified the instrumentation compared to devices using electrical pulses for similar purposes. In principle, the same approach can also be applied for lysis of mammalian cells and electroporative transfection.
Blood cell counting and classification by nonflowing laser light scattering method
NASA Astrophysics Data System (ADS)
Yang, Ye; Zhang, Zhenxi; Yang, Xinhui; Jiang, Dazong; Yeo, Joon Hock
1999-11-01
A new non-flowing laser light scattering method for counting and classifying blood cells is presented. A linear charge- coupled device with 1024 elements is used to detect the scattered light intensity distribution of the blood cells. A pinhole plate is combined with the CCD to compete the focusing of the measurement system. An isotropic sphere is used to simulate the blood cell. Mie theory is used to describe the scattering of blood cells. In order to inverse the size distribution of blood cells from their scattered light intensity distribution, Powell method combined with precision punishment method is used as a dependent model method for measurement red blood cells and blood plates. Non-negative constraint least square method combined with Powell method and precision punishment method is used as an independent model for measuring white blood cells. The size distributions of white blood cells and red blood cells, and the mean diameter of red blood cells are measured by this method. White blood cells can be divided into three classes: lymphocytes, middle-sized cells and neutrocytes according to their sizes. And the number of blood cells in unit volume can also be measured by the linear dependence of blood cells concentration on scattered light intensity.
33 CFR 159.127 - Safety coliform count: Recirculating devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Safety coliform count: Recirculating devices. 159.127 Section 159.127 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159...
Impute DC link (IDCL) cell based power converters and control thereof
Divan, Deepakraj M.; Prasai, Anish; Hernendez, Jorge; Moghe, Rohit; Iyer, Amrit; Kandula, Rajendra Prasad
2016-04-26
Power flow controllers based on Imputed DC Link (IDCL) cells are provided. The IDCL cell is a self-contained power electronic building block (PEBB). The IDCL cell may be stacked in series and parallel to achieve power flow control at higher voltage and current levels. Each IDCL cell may comprise a gate drive, a voltage sharing module, and a thermal management component in order to facilitate easy integration of the cell into a variety of applications. By providing direct AC conversion, the IDCL cell based AC/AC converters reduce device count, eliminate the use of electrolytic capacitors that have life and reliability issues, and improve system efficiency compared with similarly rated back-to-back inverter system.
A nonimaging scintillation probe to measure penile hemodynamics.
Zuckier, L S; Korupolu, G R; Gladshteyn, M; Sattenberg, R; Goldstein, R; Ricciardi, R; Goodwin, P; Melman, A; Blaufox, M D
1995-12-01
We have developed a penile nonimaging scintillation (PNIS) probe consisting of a plastic well-type scintillation crystal interfaced to a portable computer and acquisition board. This report describes the design of the PNIS probe, performance characteristics, mode of usage and illustrative results which demonstrate its capabilities. With the PNIS probe, penile blood-pool studies were performed in nine patients utilizing 3.7 MBq (100 microCi) autologous 99mTc-labeled red blood cells (RBCs). Venous blood standards were assayed to enable conversion of the count rate to volummetric measurements. Washin of peripherally administered 99mTc-RBCs was mathematically analyzed to estimate penile blood volume and cavernosal flow rate in the flaccid state. The rate of change of penile blood volume after intracavernosal vasodilators was used to generate measures of stimulated flow. A major advantage of this device over the gamma-camera is a 3300-fold increase in count rate sensitivity, which allows for markedly improved temporal resolution while significantly reducing the radiopharmaceutical dosage. Additionally, the PNIS probe is portable, economical and is not dependent on operator-defined regions of interest. Count rate sensitivity is relatively constant within the bore, with the exception of the proximal region adjacent to the opening, where geometric efficiency is reduced. The PNIS probe is an effective device for measuring penile activity in radionuclide studies, allowing for acquisition of time-activity curves of the penis during flaccid washin of peripherally labeled red blood cells and after pharmacologic stimulation to induce erection.
Evaluation of quantitative PCR measurement of bacterial colonization of epithelial cells.
Schmidt, Marcin T; Olejnik-Schmidt, Agnieszka K; Myszka, Kamila; Borkowska, Monika; Grajek, Włodzimierz
2010-01-01
Microbial colonization is an important step in establishing pathogenic or probiotic relations to host cells and in biofilm formation on industrial or medical devices. The aim of this work was to verify the applicability of quantitative PCR (Real-Time PCR) to measure bacterial colonization of epithelial cells. Salmonella enterica and Caco-2 intestinal epithelial cell line was used as a model. To verify sensitivity of the assay a competition of the pathogen cells to probiotic microorganism was tested. The qPCR method was compared to plate count and radiolabel approach, which are well established techniques in this area of research. The three methods returned similar results. The best quantification accuracy had radiolabel method, followed by qPCR. The plate count results showed coefficient of variation two-times higher than this of qPCR. The quantitative PCR proved to be a reliable method for enumeration of microbes in colonization assay. It has several advantages that make it very useful in case of analyzing mixed populations, where several different species or even strains can be monitored at the same time.
Fragmented red cells reference range (Sysmex XN(®) automated blood cell counter).
Lesesve, Jean-François; Daigney, Amandine; Henry, Sylvain; Speyer, Elodie
2015-01-01
Fragmented red cells (FRCs) is a new parameter automatedly determined by recent blood cell counters. Their count might be of interest because FRCs are supposed to reflect schistocytes counts measured on a stained peripheral blood smear observed under the microscope. But FRCs depend from the technical procedure used to detect them and thus reference ranges are device-dependent. The XN-9000(®) is one of the last model from Sysmex series. We aimed to establish reference range for FRCs, from 2389 controls. The mean ± SD was 0.32% ± 0.81, the median 0.02% (95% confidence interval ot the mean: 0.29-0.35%). We observed that the percentage of red blood cells with less than 17 pg of hemoglobin content (Hypo-He) was correlated to FRC increase, Hypo-He increase resulting in spurious FRCs majoration. FRCs reference range should be useful for: 1) laboratory staff in order to select which blood smears to check optically; 2) Sysmex company to set-up more optimal rules proposed with the counter (automated making of blood smear).
Design of time interval generator based on hybrid counting method
NASA Astrophysics Data System (ADS)
Yao, Yuan; Wang, Zhaoqi; Lu, Houbing; Chen, Lian; Jin, Ge
2016-10-01
Time Interval Generators (TIGs) are frequently used for the characterizations or timing operations of instruments in particle physics experiments. Though some "off-the-shelf" TIGs can be employed, the necessity of a custom test system or control system makes the TIGs, being implemented in a programmable device desirable. Nowadays, the feasibility of using Field Programmable Gate Arrays (FPGAs) to implement particle physics instrumentation has been validated in the design of Time-to-Digital Converters (TDCs) for precise time measurement. The FPGA-TDC technique is based on the architectures of Tapped Delay Line (TDL), whose delay cells are down to few tens of picosecond. In this case, FPGA-based TIGs with high delay step are preferable allowing the implementation of customized particle physics instrumentations and other utilities on the same FPGA device. A hybrid counting method for designing TIGs with both high resolution and wide range is presented in this paper. The combination of two different counting methods realizing an integratable TIG is described in detail. A specially designed multiplexer for tap selection is emphatically introduced. The special structure of the multiplexer is devised for minimizing the different additional delays caused by the unpredictable routings from different taps to the output. A Kintex-7 FPGA is used for the hybrid counting-based implementation of a TIG, providing a resolution up to 11 ps and an interval range up to 8 s.
Numerical and experimental evaluation of microfluidic sorting devices.
Taylor, Jay K; Ren, Carolyn L; Stubley, G D
2008-01-01
The development of lab-on-a-chip devices calls for the isolation or separation of specific bioparticles or cells. The design of a miniaturized cell-sorting device for handheld operation must follow the strict parameters associated with lab-on-a-chip technology. The limitations include applied voltage, high efficiency of cell-separation, reliability, size, flow control, and cost, among others. Currently used designs have achieved successful levels of cell isolation; however, further improvements in the microfluidic chip design are important to incorporate into larger systems. This study evaluates specific design modifications that contribute to the reduction of required applied potential aiming for developing portable devices, improved operation reliability by minimizing induced pressure disturbance when electrokinetic pumping is employed, and improved flow control by incorporating directing streams achieving dynamic sorting and counting. The chip designs fabricated in glass and polymeric materials include asymmetric channel widths for sample focusing, nonuniform channel depth for minimizing induced pressure disturbance, directing streams to assist particle flow control, and online filters for reducing channel blockage. Fluorescence-based visualization experimental results of electrokinetic focusing, flow field phenomena, and dynamic sorting demonstrate the advantages of the chip design. Numerical simulations in COMSOL are validated by the experimental data and used to investigate the effects of channel geometry and fluid properties on the flow field.
Evaluation of canine red blood cell quality after processing with an automated cell salvage device.
Hofbauer, Nina; Windberger, Ursula; Schwendenwein, Ilse; Tichy, Alexander; Eberspächer, Eva
2016-05-01
To evaluate the properties of RBC concentrate harvested after processing fresh whole blood units from healthy dogs with an automated cell salvage device. Prospective, in vitro, experimental study. University teaching hospital. Sixteen healthy, privately owned dogs of various breeds. Fresh canine whole blood collected in bags with citrate phosphate dextrose adenine solution was processed with an automated cell salvage device and analyzed in vitro. Laboratory values determined before (baseline, from a catheter sample) and after processing RBCs (procRBCs) included a complete blood count, selected blood chemistry analytes, erythrocyte osmotic resistance, whole blood viscosity, RBC aggregation, and RBC deformability. Total recovery of RBCs was 80% ± 12%. Hematocrit of the procRBCs yielded by the device was 77% ± 3.7% (mean ± standard deviation). Gross morphology of the RBCs remained unchanged. The mean corpuscular volume, erythrocyte osmotic resistance, RBC deformability, RBC aggregation, and the activity of lactate dehydrogenase showed minor but statistically significant changes from baseline. No differences in the concentrations of free hemoglobin were observed. Whole blood viscosity was less in the procRBCs. Seventy-seven percent (mean) of the platelets were washed out, while a mean of 57% of the leukocytes remained in the procRBCs. Although processing canine blood with this automated cell salvage device leads to slight changes in some properties of RBCs, most of these changes are comparable to changes seen in human blood after processing. Present data indicate that the use of this cell salvage device does not induce changes in canine RBC concentrate that would preclude its use for transfusion. © Veterinary Emergency and Critical Care Society 2016.
Diagnostic utility of combined retinal ganglion cell count estimates in Japanese glaucoma patients.
Sakamoto, Mari; Mori, Sotaro; Ueda, Kaori; Akashi, Azusa; Inoue, Yukako; Kurimoto, Takuji; Kanamori, Akiyasu; Yamada, Yuko; Nakamura, Makoto
2018-01-01
To assess the combined estimate of retinal ganglion cell (RGC) count developed by Medeiros et al. as a tool for diagnosis of glaucoma in Japanese patients. Cross-sectional study. Thirty-one eyes of 19 healthy controls and 106 eyes of 70 glaucoma patients underwent standard automated perimetry (SAP) and three types of spectral domain optical coherence tomography (SD-OCT) imaging using the Cirrus, RTVue, and 3D-OCT instruments. RGC counts derived from SAP and SD-OCT data were estimated using the Harwerth model (SAPrgc and OCTrgc, respectively), from which the combined RGC count estimates (CRGC) were calculated using the formula developed by Medeiros et al. Receiver operating characteristic curve (ROC) analyses were conducted for mean deviation (MD), retinal nerve fiber layer thickness (RNFLT), and CRGC. The mean OCTrgc derived from the Cirrus, RTVue, and 3D-OCT instruments were 1150, 1245, and 1316 (× 1000 cells), respectively, for the control group and 463, 519, and 516 (× 1000 cells), respectively, for the patient group. SAPrgc of the controls' group was 1526 and the patients' group, 731 (× 1000 cells), and were consistently greater than OCTrgc in both groups (a generalized estimating equation model, p < 0.001). Partial area under the curve (pAUC) of MD was 0.178, and that of RNFLT and CRGC for the three OCT instruments were 0.185, 0.18, 0.189 and 0.196, 0.196, 0.197, respectively. CRGC had larger pAUC than MD, whereas there was no or marginal difference in pAUC between CRGC and cpRNFLT, irrespective of OCT device used or glaucoma severity. CRGC proved well suited to discriminate glaucoma patients from controls. However, its clinical utility did not seem to overwhelm isolated structural measures in the tested Japanese patients.
NASA Astrophysics Data System (ADS)
Chen, Yuan-Ho
2017-05-01
In this work, we propose a counting-weighted calibration method for field-programmable-gate-array (FPGA)-based time-to-digital converter (TDC) to provide non-linearity calibration for use in positron emission tomography (PET) scanners. To deal with the non-linearity in FPGA, we developed a counting-weighted delay line (CWD) to count the delay time of the delay cells in the TDC in order to reduce the differential non-linearity (DNL) values based on code density counts. The performance of the proposed CWD-TDC with regard to linearity far exceeds that of TDC with a traditional tapped delay line (TDL) architecture, without the need for nonlinearity calibration. When implemented in a Xilinx Vertix-5 FPGA device, the proposed CWD-TDC achieved time resolution of 60 ps with integral non-linearity (INL) and DNL of [-0.54, 0.24] and [-0.66, 0.65] least-significant-bit (LSB), respectively. This is a clear indication of the suitability of the proposed FPGA-based CWD-TDC for use in PET scanners.
A side-by-side comparison of Rotorod and Burkard pollen and spore collections.
Crisp, Howard C; Gomez, Robert A; White, Kevin M; Quinn, James M
2013-08-01
The Rotorod sampler and Burkard spore trap are 2 devices commonly used to quantify airborne particles. To evaluate the differences in collections between the 2 devices for a wide range of plant pollens and fungal spores. Pollens and spores were collected simultaneously with each device on 167 days during a 1-year period. The Burkard yielded significantly higher total and individual mold spore counts. It yielded statistically higher total grass, total weed, and Urticaceae daily pollen counts, although the absolute differences were small. Daily counts were positively correlated between the 2 devices for the most abundant pollens and mold spores. The Burkard spore trap collects many more mold spores than the Rotorod over a wide variety of species. The Burkard also yielded higher total grass, total weed, and Urticaceae daily pollen counts. Despite these differences, however, either device can be used to follow trends in the most abundant pollen and mold spores. Copyright © 2013 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Rapid Isolation of Viable Circulating Tumor Cells from Patient Blood Samples
Hughes, Andrew D.; Mattison, Jeff; Powderly, John D.; Greene, Bryan T.; King, Michael R.
2012-01-01
Circulating tumor cells (CTC) are cells that disseminate from a primary tumor throughout the circulatory system and that can ultimately form secondary tumors at distant sites. CTC count can be used to follow disease progression based on the correlation between CTC concentration in blood and disease severity1. As a treatment tool, CTC could be studied in the laboratory to develop personalized therapies. To this end, CTC isolation must cause no cellular damage, and contamination by other cell types, particularly leukocytes, must be avoided as much as possible2. Many of the current techniques, including the sole FDA-approved device for CTC enumeration, destroy CTC as part of the isolation process (for more information see Ref. 2). A microfluidic device to capture viable CTC is described, consisting of a surface functionalized with E-selectin glycoprotein in addition to antibodies against epithelial markers3. To enhance device performance a nanoparticle coating was applied consisting of halloysite nanotubes, an aluminosilicate nanoparticle harvested from clay4. The E-selectin molecules provide a means to capture fast moving CTC that are pumped through the device, lending an advantage over alternative microfluidic devices wherein longer processing times are necessary to provide target cells with sufficient time to interact with a surface. The antibodies to epithelial targets provide CTC-specificity to the device, as well as provide a readily adjustable parameter to tune isolation. Finally, the halloysite nanotube coating allows significantly enhanced isolation compared to other techniques by helping to capture fast moving cells, providing increased surface area for protein adsorption, and repelling contaminating leukocytes3,4. This device is produced by a straightforward technique using off-the-shelf materials, and has been successfully used to capture cancer cells from the blood of metastatic cancer patients. Captured cells are maintained for up to 15 days in culture following isolation, and these samples typically consist of >50% viable primary cancer cells from each patient. This device has been used to capture viable CTC from both diluted whole blood and buffy coat samples. Ultimately, we present a technique with functionality in a clinical setting to develop personalized cancer therapies. PMID:22733259
Yamaguchi, Nobuyasu; Tokunaga, Yusuke; Goto, Satoko; Fujii, Yudai; Banno, Fumiya; Edagawa, Akiko
2017-06-08
Legionnaires' disease, predominantly caused by the bacterium Legionella pneumophila, has increased in prevalence worldwide. The most common mode of transmission of Legionella is inhalation of contaminated aerosols, such as those generated by cooling towers. Simple, rapid and accurate methods to enumerate L. pneumophila are required to prevent the spread of this organism. Here, we applied a microfluidic device for on-chip fluorescent staining and semi-automated counting of L. pneumophila in cooling tower water. We also constructed a portable system for rapid on-site monitoring and used it to enumerate target bacterial cells rapidly flowing in the microchannel. A fluorescently-labelled polyclonal antibody was used for the selective detection of L. pneumophila serogroup 1 in the samples. The counts of L. pneumophila in cooling tower water obtained using the system and fluorescence microscopy were similar. The detection limit of the system was 10 4 cells/ml, but lower numbers of L. pneumophila cells (10 1 to 10 3 cells/ml) could be detected following concentration of 0.5-3 L of the water sample by filtration. Our technique is rapid to perform (1.5 h), semi-automated (on-chip staining and counting), and portable for on-site measurement, and it may therefore be effective in the initial screening of Legionella contamination in freshwater.
Guo, Jinhong; Chen, Liang; Ai, Ye; Cheng, Yuanbing; Li, Chang Ming; Kang, Yuejun; Wang, Zhiming
2015-03-01
Portable diagnostic devices have emerged as important tools in various biomedical applications since they can provide an effective solution for low-cost and rapid clinical diagnosis. In this paper, we present a micropore-based resistive cytometer for the detection and enumeration of biological cells. The proposed device was fabricated on a silicon wafer by a standard microelectromechanical system processing technology, which enables a mass production of the proposed chip. The working principle of this cytometer is based upon a bias potential modulated pulse, originating from the biological particle's physical blockage of the micropore. Polystyrene particles of different sizes (7, 10, and 16 μm) were used to test and calibrate the proposed device. A finite element simulation was developed to predict the bias potential modulated pulse (peak amplitude vs. pulse bandwidth), which can provide critical insight into the design of this microfluidic flow cytometer. Furthermore, HeLa cells (a type of tumor cell lines) spiked in a suspension of blood cells, including red blood cells and white blood cells, were used to assess the performance for detecting and counting tumor cells. The proposed microfluidic flow cytometer is able to provide a promising platform to address the current unmet need for point-of-care clinical diagnosis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kim, Jaehyup; Joseph, Ranjit; Matevosyan, Karen; Sarode, Ravi
2016-12-01
Spectra Optia (Terumo BCT, Lakewood, CO) was FDA approved for red blood cell exchange (RBCx) procedures in January 2014 and is expected to replace COBE spectra (Terumo BCT) very soon in the USA. The performance characteristics of these devices for Isovolemic Hemodilution (IHD-RBCx) procedure were compared in this study. A total of 114 IHD-RBCx procedures from 19 patients were analyzed. For every patient, three procedures on each device with similar pre-procedure hematocrits were compared. Pre and post procedure laboratory parameters compared were hemoglobin S (HbS), hematocrits (Hct), platelet counts and fraction of cells remaining (FCR). Statistical analysis was performed using t-test adjusted by the Holm-Bonferroni method to reduce family-wise error rate. There were no significant differences between these two devices in regards to HbS, Hct, FCR and platelet counts (p = > 0.05). However, rinseback volume (124.2 ± 8.9 ml) and normal saline replacement volume during IHD phase (296.1 ± 97.2 ml) were lower in Spectra Optia as compared to COBE Spectra (337 ± 33.8 ml and 326.6 ± 105.2 ml, p value <0.001 and 0.030 respectively). Spectra Optia had a longer run time (107.1 ± 15.9 min vs 123.8 ± 19.6 min, p value <0.001) overall. Performance characteristics of Spectra Optia for HbS, Hct and FCR were similar to COBE Spectra for IHD-RBCx. IHD-RBCx procedure on Optia required less normal saline replacement volume and rinse back volume but with overall longer procedure run time. Copyright © 2016. Published by Elsevier Ltd.
Cell chips as new tools for cell biology--results, perspectives and opportunities.
Primiceri, Elisabetta; Chiriacò, Maria Serena; Rinaldi, Ross; Maruccio, Giuseppe
2013-10-07
Cell culture technologies were initially developed as research tools for studying cell functions, but nowadays they are essential for the biotechnology industry, with rapidly expanding applications requiring more and more advancements with respect to traditional tools. Miniaturization and integration of sensors and microfluidic components with cell culture techniques open the way to the development of cellomics as a new field of research targeting innovative analytic platforms for high-throughput studies. This approach enables advanced cell studies under controllable conditions by providing inexpensive, easy-to-operate devices. Thanks to their numerous advantages cell-chips have become a hotspot in biosensors and bioelectronics fields and have been applied to very different fields. In this review exemplary applications will be discussed, for cell counting and detection, cytotoxicity assays, migration assays and stem cell studies.
Dhar, Manjima; Pao, Edward; Renier, Corinne; Go, Derek E; Che, James; Montoya, Rosita; Conrad, Rachel; Matsumoto, Melissa; Heirich, Kyra; Triboulet, Melanie; Rao, Jianyu; Jeffrey, Stefanie S; Garon, Edward B; Goldman, Jonathan; Rao, Nagesh P; Kulkarni, Rajan; Sollier-Christen, Elodie; Di Carlo, Dino
2016-10-14
Circulating tumor cells (CTCs) have a great potential as indicators of metastatic disease that may help physicians improve cancer prognostication, treatment and patient outcomes. Heterogeneous marker expression as well as the complexity of current antibody-based isolation and analysis systems highlights the need for alternative methods. In this work, we use a microfluidic Vortex device that can selectively isolate potential tumor cells from blood independent of cell surface expression. This system was adapted to interface with three protein-marker-free analysis techniques: (i) an in-flow automated image processing system to enumerate cells released, (ii) cytological analysis using Papanicolaou (Pap) staining and (iii) fluorescence in situ hybridization (FISH) targeting the ALK rearrangement. In-flow counting enables a rapid assessment of the cancer-associated large circulating cells in a sample within minutes to determine whether standard downstream assays such as cytological and cytogenetic analyses that are more time consuming and costly are warranted. Using our platform integrated with these workflows, we analyzed 32 non-small cell lung cancer (NSCLC) and 22 breast cancer patient samples, yielding 60 to 100% of the cancer patients with a cell count over the healthy threshold, depending on the detection method used: respectively 77.8% for automated, 60-100% for cytology, and 80% for immunostaining based enumeration.
Dhar, Manjima; Pao, Edward; Renier, Corinne; Go, Derek E.; Che, James; Montoya, Rosita; Conrad, Rachel; Matsumoto, Melissa; Heirich, Kyra; Triboulet, Melanie; Rao, Jianyu; Jeffrey, Stefanie S.; Garon, Edward B.; Goldman, Jonathan; Rao, Nagesh P.; Kulkarni, Rajan; Sollier-Christen, Elodie; Di Carlo, Dino
2016-01-01
Circulating tumor cells (CTCs) have a great potential as indicators of metastatic disease that may help physicians improve cancer prognostication, treatment and patient outcomes. Heterogeneous marker expression as well as the complexity of current antibody-based isolation and analysis systems highlights the need for alternative methods. In this work, we use a microfluidic Vortex device that can selectively isolate potential tumor cells from blood independent of cell surface expression. This system was adapted to interface with three protein-marker-free analysis techniques: (i) an in-flow automated image processing system to enumerate cells released, (ii) cytological analysis using Papanicolaou (Pap) staining and (iii) fluorescence in situ hybridization (FISH) targeting the ALK rearrangement. In-flow counting enables a rapid assessment of the cancer-associated large circulating cells in a sample within minutes to determine whether standard downstream assays such as cytological and cytogenetic analyses that are more time consuming and costly are warranted. Using our platform integrated with these workflows, we analyzed 32 non-small cell lung cancer (NSCLC) and 22 breast cancer patient samples, yielding 60 to 100% of the cancer patients with a cell count over the healthy threshold, depending on the detection method used: respectively 77.8% for automated, 60–100% for cytology, and 80% for immunostaining based enumeration. PMID:27739521
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Cassandra E.; Beri, Nina R.; Gardner, Jeffrey G.
Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interactionmore » between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.« less
Nelson, Cassandra E.; Beri, Nina R.; Gardner, Jeffrey G.
2016-09-21
Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interactionmore » between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.« less
Visible Thrombolysis Acceleration of a Nanomachine Powered by Light-Driving F0F1-ATPase Motor
NASA Astrophysics Data System (ADS)
Duan, Xiaoxia; Liu, Lifeng; Jiang, Weijian; Yue, Jiachang
2015-05-01
We report on thrombolysis acceleration of a nanomachine powered by light-driving δ-subunit-free F0F1-ATPase motor. It is composed of a mechanical device, locating device, energy storage device, and propeller. The rotory δ-subunit-free F0F1-ATPase motor acts as a mechanical device, which was obtained by reconstructing an original chromatophore extracted from Rhodospirillum rubrum. We found that the bioactivity of the F0F1-ATPase motor improved greatly after reconstruction. The zeta potential of the nanomachine is about -23.4 mV. Cytotoxicity induced by the nanomachine was measured using cell counting kit (CCK)-8 assay. The A549 cells incubated with different fractional concentrations of the nanomachine within 48 h did not show obvious cytotoxicity. The locating device helps the nanomachine bind to the thrombi. Energy was easily stored by exposing the nanomachine to 600-nm-wavelength irradiation, which promoted activity of the motor. The rotation of the long propeller accelerated thrombolysis of a blood clot in vitro in the presence of urokinase (UK). This result was based on visual inspection and confirmed by a series of tests.
Leukocyte count; White blood cell count; White blood cell differential; WBC differential; Infection - WBC count; Cancer - WBC count ... called leukopenia. A count less than 4,500 cells per microliter (4.5 × 10 9 /L) is ...
Xie, Jing; Qiu, Zhifeng; Han, Yang; Li, Yanling; Song, Xiaojing; Li, Taisheng
2015-02-01
To evaluate the accuracy of lymphocyte count as a surrogate for CD(+)4T cell count in treatment-naїve HIV-infected adults. A total of 2 013 HIV-infected patients were screened at 23 sites in China. CD(+)4T cell counts were measured by flow cytometry. Correlation between CD(+)4T cell count and peripheral lymphocyte count were analyzed by spearman coefficient. AUCROC were used to evaluate the performance of lymphocyte count as a surrogate for CD(+)4T cell count. The lymphocyte count and CD(+)4T cell count of these 2 013 patients were (1 600 ± 670) × 10(6)/L and (244 ± 148) × 10(6)/L respectively. CD(+)4T cell count were positively correlated with lymphocyte count (r = 0.482, P < 0.000 1). AUCROC of lymphocyte count as a surrogate for CD(+)4T cell counts of <100×10(6)/L, <200×10(6)/L and <350×10(6)/L were 0.790 (95%CI 0.761-0.818, P < 0.000 1), 0.733 (95%CI 0.710-0.755, P < 0.000 1) and 0.732 (95%CI 0.706-0.758, P < 0.000 1) respectively. Lymphocyte count could be considerad as a potential surrogate marker for CD(+)4T cell count in HIV/AIDS patients not having access to T cell subset test by flowcytometry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Podgorsak, A; Bednarek, D; Rudin, S
2016-06-15
Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence.more » The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.« less
Fries, M; Montavon, S; Spadavecchia, C; Levionnois, O L
2017-03-01
Methods of evaluating locomotor activity can be useful in efforts to quantify behavioural activity in horses objectively. To evaluate whether an accelerometric device would be adequate to quantify locomotor activity and step frequency in horses, and to distinguish between different levels of activity and different gaits. Observational study in an experimental setting. Dual-mode (activity and step count) piezo-electric accelerometric devices were placed at each of 4 locations (head, withers, forelimb and hindlimb) in each of 6 horses performing different controlled activities including grazing, walking at different speeds, trotting and cantering. Both the activity count and step count were recorded and compared by the various activities. Statistical analyses included analysis of variance for repeated measures, receiver operating characteristic curves, Bland-Altman analysis and linear regression. The accelerometric device was able to quantify locomotor activity at each of the 4 locations investigated and to distinguish between gaits and speeds. The activity count recorded by the accelerometer placed on the hindlimb was the most accurate, displaying a clear discrimination between the different levels of activity and a linear correlation to speed. The accelerometer placed on the head was the only one to distinguish specifically grazing behaviour from standing. The accelerometer placed on the withers was unable to differentiate different gaits and activity levels. The step count function measured at the hindlimb was reliable but the count was doubled at the walk. The dual-mode accelerometric device was sufficiently accurate to quantify and compare locomotor activity in horses moving at different speeds and gaits. Positioning the device on the hindlimb allowed for the most accurate results. The step count function can be useful but must be manually corrected, especially at the walk. © 2016 EVJ Ltd.
Radiation analysis devices, radiation analysis methods, and articles of manufacture
Roybal, Lyle Gene
2010-06-08
Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.
Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications
NASA Technical Reports Server (NTRS)
Farr, William H.
2009-01-01
Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.
TIME-INTERVAL MEASURING DEVICE
Gross, J.E.
1958-04-15
An electronic device for measuring the time interval between two control pulses is presented. The device incorporates part of a previous approach for time measurement, in that pulses from a constant-frequency oscillator are counted during the interval between the control pulses. To reduce the possible error in counting caused by the operation of the counter gating circuit at various points in the pulse cycle, the described device provides means for successively delaying the pulses for a fraction of the pulse period so that a final delay of one period is obtained and means for counting the pulses before and after each stage of delay during the time interval whereby a plurality of totals is obtained which may be averaged and multplied by the pulse period to obtain an accurate time- Interval measurement.
Lee, Ada; Park, Juhee; Lim, Minji; Sunkara, Vijaya; Kim, Shine Young; Kim, Gwang Ha; Kim, Mi-Hyun; Cho, Yoon-Kyoung
2014-11-18
Circulating tumor cells (CTCs) have gained increasing attention owing to their roles in cancer recurrence and progression. Due to the rarity of CTCs in the bloodstream, an enrichment process is essential for effective target cell characterization. However, in a typical pressure-driven microfluidic system, the enrichment process generally requires complicated equipment and long processing times. Furthermore, the commonly used immunoaffinity-based positive selection method is limited, as its recovery rate relies on EpCAM expression of target CTCs, which shows heterogeneity among cell types. Here, we propose a centrifugal-force-based size-selective CTC isolation platform that can isolate and enumerate CTCs from whole blood within 30 s with high purity. The device was validated using the MCF-7 breast cancer cell line spiked in phosphate-buffered saline and whole blood, and an average capture efficiency of 61% was achieved, which is typical for size-based filtration. The capture efficiency for whole blood samples varied from 44% to 84% under various flow conditions and dilution factors. Under the optimized operating conditions, a few hundred white blood cells per 1 mL of whole blood were captured, representing a 20-fold decrease compared to those obtained using a commercialized size-based CTC isolation device. In clinical validation, normalized CTC counts varied from 10 to 60 per 7.5 mL of blood from gastric and lung cancer patients, yielding a detection rate of 50% and 38%, respectively. Overall, our CTC isolation device enables rapid and label-free isolation of CTCs with high purity, which should greatly improve downstream molecular analyses of captured CTCs.
Evaluation of the spectra Optia® mononuclear cell collection procedure in multiple myeloma patients.
Long, Gwynn; Waller, Edmund K; Gregurek, Steven; Tricot, Guido; Marschner, Susanne; Bill, Jerry
2015-02-01
Peripheral blood stem cell (PBSC) rescue following myeloablative therapy is a mainstay of cancer therapy. To evaluate the ability of the Spectra Optia Apheresis System (SO), a newly developed apheresis device, the device was studied in multiple myeloma patients undergoing a first autologous PBSC transplant. To demonstrate that neutrophil recovery was not inferior to historical controls when SO harvested PBSCs were reinfused following myeloablative therapy. Multiple myeloma patients were mobilized according to the standard practice at four clinical sites. Following mobilization, MNC collections were performed on the SO. The collected cells were cryopreserved and reinfused following myeloablative chemotherapy. Neutrophil recovery defined by an absolute neutrophil count exceeding 500/μL (ANC500) was compared to historical data for patients transplanted following apheresis using the COBE Spectra (CS) device. The median day to neutrophil recovery was 12 days (range 10-14 days), with no significant difference in engraftment comparing patients transplanted with stem cells collected using the SO versus historical cohort of patients collected with the CS. CD34+ cell and MNC collection efficiency (CE) were 69.3% and 65.0% for the SO and CS, respectively. Platelet CE, product hematocrit and product granulocytes (as % of WBCs) using the SO were 21%, 2.3% and 28%, respectively. There were no device-related severe adverse events. The study's results confirm that the Spectra Optia Apheresis System's MNC Collection Protocol is safe and effective for its intended use and that engraftment kinetics of cells collected by SO is not inferior to the CS System. © 2014 Wiley Periodicals, Inc.
Skazalski, C; Whiteley, R; Hansen, C; Bahr, R
2018-05-01
Use of a commercially available wearable device to monitor jump load with elite volleyball players has become common practice. The purpose of this study was to evaluate the validity and reliability of this device, the Vert, to count jumps and measure jump height with professional volleyball players. Jump count accuracy was determined by comparing jumps recorded by the device to jumps observed through systematic video analysis of three practice sessions and two league matches performed by a men's professional volleyball team. Jumps performed by 14 players were each coded for time and jump type and individually matched to device recorded jumps. Jump height validity of the device was examined against reference standards as participants performed countermovement jumps on a force plate and volleyball-specific jumps with a Vertec. The Vert device accurately counted 99.3% of the 3637 jumps performed during practice and match play. The device showed excellent jump height interdevice reliability for two devices placed in the same pouch during volleyball jumps (r = .99, 95% CI 0.98-0.99). The device had a minimum detectable change (MDC) of 9.7 cm and overestimated jump height by an average of 5.5 cm (95% CI 4.5-6.5) across all volleyball jumps. The Vert device demonstrates excellent accuracy counting volleyball-specific jumps during training and competition. While the device is not recommended to measure maximal jumping ability when precision is needed, it provides an acceptable measure of on-court jump height that can be used to monitor athlete jump load. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting.
Treacy, Daniel; Hassett, Leanne; Schurr, Karl; Chagpar, Sakina; Paul, Serene S; Sherrington, Catherine
2017-05-01
Commonly used activity monitors have been shown to be accurate in counting steps in active people; however, further validation is needed in slower walking populations. To determine the validity of activity monitors for measuring step counts in rehabilitation inpatients compared with visually observed step counts. To explore the influence of gait parameters, activity monitor position, and use of walkers on activity monitor accuracy. One hundred and sixty-six inpatients admitted to a rehabilitation unit with an average walking speed of 0.4 m/s (SD 0.2) wore 16 activity monitors (7 different devices in different positions) simultaneously during 6-minute and 6-m walks. The number of steps taken during the tests was also counted by a physical therapist. Gait parameters were assessed using the GAITRite system. To analyze the influence of different gait parameters, the percentage accuracy for each monitor was graphed against various gait parameters for each activity monitor. The StepWatch, Fitbit One worn on the ankle and the ActivPAL showed excellent agreement with observed step count (ICC 2,1 0.98; 0.92; 0.78 respectively). Other devices (Fitbit Charge, Fitbit One worn on hip, G-Sensor, Garmin Vivofit, Actigraph) showed poor agreement with the observed step count (ICC 2,1 0.12-0.40). Percentage agreement with observed step count was highest for the StepWatch (mean 98%). The StepWatch and the Fitbit One worn on the ankle maintained accuracy in individuals who walked more slowly and with shorter strides but other devices were less accurate in these individuals. There were small numbers of participants for some gait parameters. The StepWatch showed the highest accuracy and closest agreement with observed step count. This device can be confidently used by researchers for accurate measurement of step counts in inpatient rehabilitation in individuals who walk slowly. If immediate feedback is desired, the Fitbit One when worn on the ankle would be the best choice for this population. © 2017 American Physical Therapy Association
Comparison of Plateletpheresis on the Fenwal Amicus and Fresenius Com.Tec Cell Separators.
Altuntas, Fevzi; Sari, Ismail; Kocyigit, Ismail; Kaynar, Leylagul; Hacioglu, Sibel; Ozturk, Ahmet; Oztekin, Mehmet; Solmaz, Musa; Eser, Bulent; Cetin, Mustafa; Unal, Ali
2008-01-01
SUMMARY: BACKGROUND: A variety of apheresis devices are now available on the market for plateletapheresis. We compared two apheresis instruments (Fenwal Amicus and Fresenius COM.TEC) with regard to processing time, platelet (PLT) yield and efficiency, and white blood cell (WBC) content. MATERIAL AND METHODS: Donors undergoing plateletpheresis were randomly separated into two groups (either the Amicus or the COM.TEC cell separator). RESULTS: In the pre-apheresis setting, 32 plateletpheresis procedures performed with each instrument revealed no significant differences in donors' sex, age, weight, height and total blood volume between the two groups. However, the pre-apheresis PLT count was higher with the COM.TEC than with the Amicus (198 × 10(3)/μl vs. 223 × 10(3)/μl; p = 0.035). The blood volume processed to reach a target PLT yield of ≥3.3 × 10(11) was higher in the COM.TEC compared to the Amicus (3,481 vs. 2,850 ml; p < 0.001). The median separation time was also significantly longer in the COM.TEC than in the Amicus (61 vs. 44 min; p < 0.001). 91 and 88% of the PLT products collected with the Amicus and the COM.TEC, respectively, had a PLT count of >3.3 × 10(11) (p = 0.325). All products obtained with both instruments had WBC counts lower than 5 ↔ 10(6), as required. There was no statistical difference with regard to collection efficiency between the devices (55 ± 15 vs. 57 ± 15%; p = 0.477). However, the collection rate was significantly higher with the Amicus compared to the COM.TEC instrument (0.077 ± 0.012 × 10(11) vs. 0.057 ± 0.008 × 10(11) PLT/min; p < 0.001). CONCLUSION: Both instruments collected platelets efficiently. Additionally, consistent leukoreduction was obtained with both instruments; however, compared with the COM.TEC instrument, the Amicus reached the PLT target yield more quickly.
Liu, Xu; Huang, Xiwei; Jiang, Yu; Xu, Hang; Guo, Jing; Hou, Han Wei; Yan, Mei; Yu, Hao
2017-08-01
Based on a 3.2-Megapixel 1.1- μm-pitch super-resolution (SR) CMOS image sensor in a 65-nm backside-illumination process, a lens-free microfluidic cytometer for complete blood count (CBC) is demonstrated in this paper. Backside-illumination improves resolution and contrast at the device level with elimination of surface treatment when integrated with microfluidic channels. A single-frame machine-learning-based SR processing is further realized at system level for resolution correction with minimum hardware resources. The demonstrated microfluidic cytometer can detect the platelet cells (< 2 μm) required in CBC, hence is promising for point-of-care diagnostics.
21 CFR 864.8175 - Calibrator for platelet counting.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...
21 CFR 864.8175 - Calibrator for platelet counting.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...
21 CFR 864.8175 - Calibrator for platelet counting.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...
21 CFR 864.8175 - Calibrator for platelet counting.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...
21 CFR 864.8175 - Calibrator for platelet counting.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Calibrator for platelet counting. 864.8175 Section 864.8175 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Reagents § 864.8175 Calibrator for...
Optimally achieving milk bulk tank somatic cell count thresholds.
Troendle, Jason A; Tauer, Loren W; Gröhn, Yrjo T
2017-01-01
High somatic cell count in milk leads to reduced shelf life in fluid milk and lower processed yields in manufactured dairy products. As a result, farmers are often penalized for high bulk tank somatic cell count or paid a premium for low bulk tank somatic cell count. Many countries also require all milk from a farm to be lower than a specified regulated somatic cell count. Thus, farms often cull cows that have high somatic cell count to meet somatic cell count thresholds. Rather than naïvely cull the highest somatic cell count cows, a mathematical programming model was developed that determines the cows to be culled from the herd by maximizing the net present value of the herd, subject to meeting any specified bulk tank somatic cell count level. The model was applied to test-day cows on 2 New York State dairy farms. Results showed that the net present value of the herd was increased by using the model to meet the somatic cell count restriction compared with naïvely culling the highest somatic cell count cows. Implementation of the model would be straightforward in dairy management decision software. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Nelson, Cassandra E; Beri, Nina R; Gardner, Jeffrey G
2016-11-01
Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interaction between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. We applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present. Copyright © 2016 Elsevier B.V. All rights reserved.
Zeh, Clement; Rose, Charles E; Inzaule, Seth; Desai, Mitesh A; Otieno, Fredrick; Humwa, Felix; Akoth, Benta; Omolo, Paul; Chen, Robert T; Kebede, Yenew; Samandari, Taraz
2017-09-01
CD4+ T-lymphocyte count testing at the point-of-care (POC) may improve linkage to care of persons diagnosed with HIV-1 infection, but the accuracy of POC devices when operated by lay-counselors in the era of task-shifting is unknown. We examined the accuracy of Alere's Pima™ POC device on both capillary and venous blood when performed by lay-counselors and laboratory technicians. In Phase I, we compared the perfomance of POC against FACSCalibur™ for 280 venous specimens by laboratory technicians. In Phase II we compared POC performance by lay-counselors versus laboratory technicians using 147 paired capillary and venous specimens, and compared these to FACSCalibur™. Statistical analyses included Bland-Altman analyses, concordance correlation coefficient, sensitivity, and specificity at treatment eligibility thresholds of 200, 350, and 500cells/μl. Phase I: POC sensitivity and specificity were 93.0% and 84.1% at 500cells/μl, respectively. Phase II: Good agreement was observed for venous POC results from both lay-counselors (concordance correlation coefficient (CCC)=0.873, bias -86.4cells/μl) and laboratory technicians (CCC=0.920, bias -65.7cells/μl). Capillary POC had good correlation: lay-counselors (CCC=0.902, bias -71.2cells/μl), laboratory technicians (CCC=0.918, bias -63.0cells/μl). Misclassification at the 500 cells/μl threshold for venous blood was 13.6% and 10.2% for lay-counselors and laboratory technicians and 12.2% for capillary blood in both groups. POC tended to under-classify the CD4 values with increasingly negative bias at higher CD4 values. Pima™ results were comparable to FACSCalibur™ for both venous and capillary specimens when operated by lay-counselors. POC CD4 testing has the potential to improve linkage to HIV care without burdening laboratory technicians in resource-limited settings. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Xie, Dengling; Xie, Yanjun; Liu, Peng; Tong, Lieshu; Chu, Kaiqin; Smith, Zachary J.
2017-02-01
Current flow-based blood counting devices require expensive and centralized medical infrastructure and are not appropriate for field use. In this paper we report a method to count red blood cells, white blood cells as well as platelets through a low-cost and fully-automated blood counting system. The approach consists of using a compact, custom-built microscope with large field-of-view to record bright-field and fluorescence images of samples that are diluted with a single, stable reagent mixture and counted using automatic algorithms. Sample collection is performed manually using a spring loaded lancet, and volume-metering capillary tubes. The capillaries are then dropped into a tube of pre-measured reagents and gently shaken for 10-30 seconds. The sample is loaded into a measurement chamber and placed on a custom 3D printed platform. Sample translation and focusing is fully automated, and a user has only to press a button for the measurement and analysis to commence. Cost of the system is minimized through the use of custom-designed motorized components. We performed a series of comparative experiments by trained and untrained users on blood from adults and children. We compare the performance of our system, as operated by trained and untrained users, to the clinical gold standard using a Bland-Altman analysis, demonstrating good agreement of our system to the clinical standard. The system's low cost, complete automation, and good field performance indicate that it can be successfully translated for use in low-resource settings where central hematology laboratories are not accessible.
Guarner, Jeannette; Atuan, Maria Ana; Nix, Barbara; Mishak, Christopher; Vejjajiva, Connie; Curtis, Cheri; Park, Sunita; Mullins, Richard
2010-01-01
Each institution sets specific parameters obtained by automated hematology analyzers to trigger manual counts. We designed a process to decrease the number of manual differential cell counts without impacting patient care. We selected new criteria that prompt manual counts and studied the impact these changes had in 2 days of work and in samples of patients with newly diagnosed leukemia, sickle cell disease, and presence of left shift. By using fewer parameters and expanding our ranges we decreased the number of manual counts by 20%. The parameters that prompted manual counts most frequently were the presence of blast flags and nucleated red blood cells, 2 parameters that were not changed. The parameters that accounted for a decrease in the number of manual counts were the white blood cell count and large unstained cells. Eight of 32 patients with newly diagnosed leukemia did not show blast flags; however, other parameters triggered manual counts. In 47 patients with sickle cell disease, nucleated red cells and red cell variability prompted manual review. Bands were observed in 18% of the specimens and 4% would not have been counted manually with the new criteria, for the latter the mean band count was 2.6%. The process we followed to evaluate hematological parameters that reflex to manual differential cell counts increased efficiency without compromising patient care in our hospital system.
Jauchem, James R; Bernhard, Joshua A; Cerna, Cesario Z; Lim, Tiffany Y; Seaman, Ronald L; Tarango, Melissa
2013-09-01
In previous studies hematocrit has been consistently increased in an anesthetized animal model after exposures to TASER(®) conducted energy weapons (CEWs). In the present study we analyzed changes in blood cell counts and red blood cell membrane proteins following two 30-s applications of a TASER C2 device (which is designed for civilian use). Hematocrit increased significantly from 33.2 ± 2.4 (mean ± SD) to 42.8 ± 4.6 % immediately after CEW exposure of eleven pigs (Sus scrofa). Red blood cell count increased significantly from 6.10 ± 0.55 × 10(12)/L to 7.45 ± 0.94 × 10(12)/L, and mean corpuscular volume increased significantly from 54.5 ± 2.4 fl to 57.8 ± 2.6 fl. Mean corpuscular hemoglobin concentration decreased significantly from 20.5 ± 0.7 to 18.5 ± 0.6 mM. Thirty protein spots (from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis, selected for detailed comparison) exhibited greater densities 30-min post-exposure compared with pre-exposure values. A greater number of echinocytes were observed following CEW exposure. On the basis of these results it appears that, during the strong muscle contractions produced by TASER CEWs, a specific population of red blood cells (RBCs) may be released from the spleen or other reservoirs within the body. The total time of CEW exposure in the present study was relatively long compared with exposures in common law-enforcement scenarios. Despite statistically significant changes in red blood cell counts (and other measures directly related to RBCs), the alterations were short-lived. The transient nature of the changes would be likely to counteract any potentially detrimental effects.
NASA Astrophysics Data System (ADS)
Tremsin, A. S.; Vallerga, J. V.; McPhate, J. B.; Siegmund, O. H. W.
2015-07-01
Many high resolution event counting devices process one event at a time and cannot register simultaneous events. In this article a frame-based readout event counting detector consisting of a pair of Microchannel Plates and a quad Timepix readout is described. More than 104 simultaneous events can be detected with a spatial resolution of 55 μm, while >103 simultaneous events can be detected with <10 μm spatial resolution when event centroiding is implemented. The fast readout electronics is capable of processing >1200 frames/sec, while the global count rate of the detector can exceed 5×108 particles/s when no timing information on every particle is required. For the first generation Timepix readout, the timing resolution is limited by the Timepix clock to 10-20 ns. Optimization of the MCP gain, rear field voltage and Timepix threshold levels are crucial for the device performance and that is the main subject of this article. These devices can be very attractive for applications where the photon/electron/ion/neutron counting with high spatial and temporal resolution is required, such as energy resolved neutron imaging, Time of Flight experiments in lidar applications, experiments on photoelectron spectroscopy and many others.
Where are we at with point-of-care testing in haematology?
Briggs, Carol; Kimber, Simon; Green, Laura
2012-09-01
Point-of-care testing (POCT) in haematology has continued to grow in popularity and uptake throughout the world. The increasing demand to reduce the turnaround time of test results, coupled with rapid improvements in technology, have led to the development of several devices that are designed for use in different clinical settings, with the hope of improving patient care. The most used POCT in haematology is measurement of haemoglobin concentration. Other POCT devices (used primarily in developing countries) for malaria screening and CD4+ T-lymphocytes for quantification of human-immunodeficiency-virus are becoming the cornerstone for the diagnosis and management of these disorders. New devices are also available for red cell indices, white blood cell count and platelets. In this review clinical studies that validate the use of such devices will be discussed, as well as the advantages and disadvantages of POCT in haematology. A disadvantage of POCT is a lack of training, poor standardization in obtaining blood samples and insufficient internal/external quality assessment. As there is every reason to expect that POCT use will increase in all pathology disciplines, including haematology, it is imperative that systems are put in place to oversee these issues. © 2012 Blackwell Publishing Ltd.
Choudhry, Priya
2016-01-01
Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849
Analysis of Platelet-Rich Plasma Extraction
Fitzpatrick, Jane; Bulsara, Max K.; McCrory, Paul Robert; Richardson, Martin D.; Zheng, Ming Hao
2017-01-01
Background: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. Purpose: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. Study Design: Controlled laboratory study. Methods: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. Results: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. Conclusion: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. Clinical Relevance: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. PMID:28210651
Long terms trends in CD4+ cell counts, CD8+ cell counts, and the CD4+ : CD8+ ratio
Hughes, Rachael A.; May, Margaret T.; Tilling, Kate; Taylor, Ninon; Wittkop, Linda; Reiss, Peter; Gill, John; Schommers, Philipp; Costagliola, Dominique; Guest, Jodie L.; Lima, Viviane D.; d’Arminio Monforte, Antonella; Smith, Colette; Cavassini, Matthias; Saag, Michael; Castilho, Jessica L.; Sterne, Jonathan A.C.
2018-01-01
Objective: Model trajectories of CD4+ and CD8+ cell counts after starting combination antiretroviral therapy (ART) and use the model to predict trends in these counts and the CD4+ : CD8+ ratio. Design: Cohort study of antiretroviral-naïve HIV-positive adults who started ART after 1997 (ART Cohort Collaboration) with more than 6 months of follow-up data. Methods: We jointly estimated CD4+ and CD8+ cell count trends and their correlation using a bivariate random effects model, with linear splines describing their population trends, and predicted the CD4+ : CD8+ ratio trend from this model. We assessed whether CD4+ and CD8+ cell count trends and the CD4+ : CD8+ ratio trend varied according to CD4+ cell count at start of ART (baseline), and, whether these trends differed in patients with and without virological failure more than 6 months after starting ART. Results: A total of 39 979 patients were included (median follow-up was 53 months). Among patients with baseline CD4+ cell count at least 50 cells/μl, predicted mean CD8+ cell counts continued to decrease between 3 and 15 years post-ART, partly driving increases in the predicted mean CD4+ : CD8+ ratio. During 15 years of follow-up, normalization of the predicted mean CD4+ : CD8+ ratio (to >1) was only observed among patients with baseline CD4+ cell count at least 200 cells/μl. A higher baseline CD4+ cell count predicted a shorter time to normalization. Conclusion: Declines in CD8+ cell count and increases in CD4+ : CD8+ ratio occurred up to 15 years after starting ART. The likelihood of normalization of the CD4+ : CD8+ ratio is strongly related to baseline CD4+ cell count. PMID:29851663
Objective assessment of activity in older adults at risk for mobility disability.
Marsh, Anthony P; Vance, Rachel M; Frederick, Tera L; Hesselmann, Sarah A; Rejeski, W Jack
2007-06-01
The purpose of this study was to evaluate the validity of three objective measures of physical activity (Accusplit Eagle 120 mechanical pedometer (AE120), NL-2000 electronic pedometer, and IDEEA pattern-recognition device) that varied in their levels of sophistication, among older adults at risk for mobility disability. In addition, we examined the potential influences of gait speed and body mass index (BMI) on step count accuracy. Step counts recorded on the three devices were compared against manual step counts made by two investigators as each participant walked 131 m around an indoor track at their preferred walking speed (N=29; 75.8+/-4.2 yr). Gait speed was determined by dividing total distance walked by time to completion. BMI was calculated from height and body mass measurements. All three devices significantly underestimated steps taken (AE120=22.8+/-53.9 steps; NL-2000=4.0+/-5.8 steps; IDEEA=5.6+/-7.8 steps), but there was no significant difference between devices (P=0.084). Steps counted by the AE120, NL-2000, and IDEEA were significantly correlated with manual step counts (r=0.508, 0.980, and 0.965, respectively; P
Tanada, H; Ikemoto, T; Masutani, R; Tanaka, H; Takubo, T
2014-02-01
In this study, we evaluated the performance of the ADVIA 120 hematology system for cerebrospinal fluid (CSF) assay. Cell counts and leukocyte differentials in CSF were examined with the ADVIA 120 hematology system, while simultaneously confirming an effective hemolysis agent for automated CSF cell counts. The detection limits of both white blood cell (WBC) counts and red blood cell (RBC) counts on the measurement of CSF cell counts by the ADVIA 120 hematology system were superior at 2 cells/μL (10(-6) L). The WBC count was linear up to 9.850 cells/μL, and the RBC count was linear up to approximately 20 000 cells/μL. The intrarun reproducibility indicated good precision. The leukocyte differential of CSF cells, performed by the ADVIA120 hematology system, showed good correlation with the microscopic procedure. The VersaLyse hemolysis solution efficiently lysed the samples without interfering with cell counts and leukocyte differential, even in a sample that included approximately 50 000/μL RBC. These data show the ADVIA 120 hematology system correctly measured the WBC count and leukocyte differential in CSF. The VersaLyse hemolysis solution is considered to be optimal for hemolysis treatment of CSF when measuring cell counts and differentials by the ADVIA 120 hematology system. © 2013 John Wiley & Sons Ltd.
Point-of-care, portable microfluidic blood analyzer system
NASA Astrophysics Data System (ADS)
Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.
2012-03-01
Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.
Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A
2018-02-01
Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.
Prognostic health monitoring in switch-mode power supplies with voltage regulation
NASA Technical Reports Server (NTRS)
Hofmeister, James P (Inventor); Judkins, Justin B (Inventor)
2009-01-01
The system includes a current injection device in electrical communication with the switch mode power supply. The current injection device is positioned to alter the initial, non-zero load current when activated. A prognostic control is in communication with the current injection device, controlling activation of the current injection device. A frequency detector is positioned to receive an output signal from the switch mode power supply and is able to count cycles in a sinusoidal wave within the output signal. An output device is in communication with the frequency detector. The output device outputs a result of the counted cycles, which are indicative of damage to an a remaining useful life of the switch mode power supply.
Parallel single-cell analysis of active caspase-3/7 in apoptotic and non-apoptotic cells.
Ledvina, Vojtěch; Janečková, Eva; Matalová, Eva; Klepárník, Karel
2017-01-01
Analysing the chemical content of individual cells has already been proven to reveal unique information on various biological processes. Single-cell analysis provides more accurate and reliable results for biology and medicine than analyses of extracts from cell populations, where a natural heterogeneity is averaged. To meet the requirements in the research of important biologically active molecules, such as caspases, we have developed a miniaturized device for simultaneous analyses of individual cells. A stainless steel body with a carousel holder enables high-sensitivity parallel detections in eight microvials. The holder is mounted in front of a photomultiplier tube with cooled photocathode working in photon counting mode. The detection of active caspase-3/7, central effector caspases in apoptosis, in single cells is based on the bioluminescence chemistry commercially available as Caspase-Glo ® 3/7 reagent developed by Promega. Individual cells were captured from a culture medium under microscope and transferred by micromanipulator into detection microvial filled with the reagent. As a result of testing, the limits of detection and quantification were determined to be 0.27/0.86 of active caspase-3/7 content in an average apoptotic cell and 0.46/2.92 for non-apoptotic cells. Application potential of this technology in laboratory diagnostics and related medical research is discussed. Graphical abstract Miniaturized device for simultaneous analyses of individual cells.
Microbiological challenge of four protective devices for the reconstitution of cytotoxic agents.
De Prijck, K; D'Haese, E; Vandenbroucke, J; Coucke, W; Robays, H; Nelis, H J
2008-12-01
To evaluate the susceptibility to microbial contamination that occurs during simulated handling of protective devices for the preparation of cytotoxic drug solutions. Four devices, i.e. Chemoprotect spike, Clave connector, PhaSeal and Securmix were challenged with low and high inocula of micro-organisms. The cells, transferred to the connected vials during repeated manipulations of the devices were counted by means of solid-phase cytometry. Of the four devices, PhaSeal afforded the lowest transfer of micro-organisms. Secondly, the efficiency of procedures for the disinfection of an artificially contaminated rubber stopper was compared prior to connection of the vial to the PhaSeal device. Spraying or swabbing alone was inadequate, as opposed to a combination of spraying [0.5% or 2.0% (w/v) chlorhexidine in isopropanol] and swabbing [70% (v/v) isopropanol]. Although Phaseal afforded the lowest transfer of micro-organisms, adequate disinfection of the vial prior to connection remains required. Unlike aspects of operator protection, which are well documented, the microbiological safety of protective devices for the preparation of cytotoxic drugs has not been addressed in the literature. This study estimates the susceptibility to microbial contamination during handling of four commonly used devices.
Robert, Mark E; Linthicum, Fred H
2016-01-01
Profile count method for estimating cell number in sectioned tissue applies a correction factor for double count (resulting from transection during sectioning) of count units selected to represent the cell. For human spiral ganglion cell counts, we attempted to address apparent confusion between published correction factors for nucleus and nucleolus count units that are identical despite the role of count unit diameter in a commonly used correction factor formula. We examined a portion of human cochlea to empirically derive correction factors for the 2 count units, using 3-dimensional reconstruction software to identify double counts. The Neurotology and House Histological Temporal Bone Laboratory at University of California at Los Angeles. Using a fully sectioned and stained human temporal bone, we identified and generated digital images of sections of the modiolar region of the lower first turn of cochlea, identified count units with a light microscope, labeled them on corresponding digital sections, and used 3-dimensional reconstruction software to identify double-counted count units. For 25 consecutive sections, we determined that double-count correction factors for nucleus count unit (0.91) and nucleolus count unit (0.92) matched the published factors. We discovered that nuclei and, therefore, spiral ganglion cells were undercounted by 6.3% when using nucleolus count units. We determined that correction factors for count units must include an element for undercounting spiral ganglion cells as well as the double-count element. We recommend a correction factor of 0.91 for the nucleus count unit and 0.98 for the nucleolus count unit when using 20-µm sections. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Validation of the Sysmex sp-1000i automated slide preparer-stainer in a clinical laboratory
de Bitencourt, Eberson Damião dos Santos; Voegeli, Carlos Franco; Onzi, Gabriela dos Santos; Boscato, Sara Cardoso; Ghem, Carine; Munhoz, Terezinha
2013-01-01
Background The speed and quality of information have become essential items in the release of laboratory reports. The Sysmex®SP1000-I device has been developed to prepare and stain smear slides. However, for a device to be cleared for use in the laboratory routine it must pass through a validation process. Objective To evaluate the performance and reliability of the Sysmex® SP-1000i slide preparer-stainer incorporated into the routine of a hospital laboratory in Porto Alegre. Methods Peripheral blood samples of patients attending the laboratory for ambulatory exams with leukocyte counts between 7000/°L and 12,000/°L were evaluated, independent of gender and age. Two slides were prepared for each sample using the Sysmex® SP-1000i equipment; one of the slides was used to perform quality control tests using the CellaVision® DM96 device, and the other slide was used to compare pre-classification by the same device and the classification performed by a pharmacist-biochemist. Results The results of all the slides used as controls were acceptable according to the quality control test as established by the manufacturer of the device. In the comparison between the automated pre-classification and the classification made by the professional, there was an acceptable variation in the differential counts of leukocytes for 90% of the analyzed slides. Pearson correlation coefficient showed a strong correlation for band neutrophils (r = 0.802; p-value < 0.001), segmented neutrophils (r = 0.963; p-value < 0.001), eosinophils (r = 0.958; p-value < 0.001), lymphocytes (r = 0.985; p-value < 0.001) and atypical lymphocytes (r = 0.866; p-value < 0.001) using both methods. The red blood cell analysis was adequate for all slides analyzed by the equipment and by the professional. Conclusion The new Sysmex®SP1000-i methodology was found to be reliable, fast and safe for the routines of medium and large laboratories, improving the quality of microscopic analysis in complete blood counts. PMID:24478606
Wright, Stephen T; Carr, Andrew; Woolley, Ian; Giles, Michelle; Hoy, Jennifer; Cooper, David A; Law, Matthew G
2011-09-01
To examine CD4 cell responses to combination antiretroviral therapy (cART) in patients enrolled in the Australian HIV Observational Database who commenced cART at CD4 cell counts >350 cells per microliter. CD4 cell counts were modelled using random effects, repeated measurement models in 432 HIV-infected adults from Australian HIV Observational Database who commenced their first cART regimen and had a baseline CD4 count >350 cells per microliter. Using published AIDS and/or death incidence rates combined with the data summarized by time and predicted CD4 cell count, we calculated the expected reduction in risk of an event for different starting baseline CD4 strata. Mean CD4 counts increased above 500 cells per microliter in all baseline CD4 strata by 12 months (means of 596, 717, and 881 cells/μL in baseline CD4 strata 351-500, 501-650, and >650 cells/μL, respectively) and after 72 months since initiating cART, mean CD4 cell counts (by increasing baseline CD4 strata) were 689, 746, 742 cells per microliter. The expected reduction in risk of mortality for baseline CD4 counts >650 cells per microliter relative to 351-500 cells per microliter was approximately 8%, an absolute risk reduction 0.33 per 1000 treated patient-years. Patients starting cART at high CD4 cell counts (>650 cells/μL) tend to maintain this immunological level over 6 years of follow-up. Patients starting from 351 to 500 CD4 cells per microliter achieve levels of >650 cells per microliter after approximately 3 years of cART. Initiating cART with a baseline CD4 count 501-650 or >650 cells per microliter relative to 351-500 cells per microliter indicated a minimal reduction in risk of AIDS incidence and/or death.
Gaglani, Shiv; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele
2015-01-01
Objectives: This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. Methods: This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Results: Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. Conclusions: These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested. PMID:26719825
Gaglani, Shiv; Moore, Jessica; Haynes, M Ryan; Hoffberger, Jamie B; Rigamonti, Daniele
2015-11-17
This study seeks to validate the use of activity monitors to detect and record gait abnormalities, potentially identifying patients with idiopathic normal pressure hydrocephalus (iNPH) prior to the onset of cognitive or urinary symptoms. This study compared the step counts of four common activity monitors (Omron Step Counter HJ-113, New Lifestyles 2000, Nike Fuelband, and Fitbit Ultra) to an observed step count in 17 patients with confirmed iNPH. Of the four devices, the Fitbit Ultra (Fitbit, Inc., San Francisco, CA) provided the most accurate step count. The correlation with the observed step count was significantly higher (p<0.009) for the Fitbit Ultra than for any of the other three devices. These preliminary findings suggest that existing activity monitors have variable efficacy in the iNPH patient population and that the MEMS tri-axial accelerometer and algorithm of the Fitbit Ultra provides the most accurate gait measurements of the four devices tested.
Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.
2014-01-01
Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213
Visual Estimation of Bacterial Growth Level in Microfluidic Culture Systems.
Kim, Kyukwang; Kim, Seunggyu; Jeon, Jessie S
2018-02-03
Microfluidic devices are an emerging platform for a variety of experiments involving bacterial cell culture, and has advantages including cost and convenience. One inevitable step during bacterial cell culture is the measurement of cell concentration in the channel. The optical density measurement technique is generally used for bacterial growth estimation, but it is not applicable to microfluidic devices due to the small sample volumes in microfluidics. Alternately, cell counting or colony-forming unit methods may be applied, but these do not work in situ; nor do these methods show measurement results immediately. To this end, we present a new vision-based method to estimate the growth level of the bacteria in microfluidic channels. We use Fast Fourier transform (FFT) to detect the frequency level change of the microscopic image, focusing on the fact that the microscopic image becomes rough as the number of cells in the field of view increases, adding high frequencies to the spectrum of the image. Two types of microfluidic devices are used to culture bacteria in liquid and agar gel medium, and time-lapsed images are captured. The images obtained are analyzed using FFT, resulting in an increase in high-frequency noise proportional to the time passed. Furthermore, we apply the developed method in the microfluidic antibiotics susceptibility test by recognizing the regional concentration change of the bacteria that are cultured in the antibiotics gradient. Finally, a deep learning-based data regression is performed on the data obtained by the proposed vision-based method for robust reporting of data.
Boron selenide semiconductor detectors for thermal neutron counting
NASA Astrophysics Data System (ADS)
Kargar, Alireza; Tower, Joshua; Cirignano, Leonard; Shah, Kanai
2013-09-01
Thermal neutron detectors in planar configuration were fabricated from B2Se3 (Boron Selenide) crystals grown at RMD Inc. All fabricated semiconductor devices were characterized for the current-voltage (I-V) characteristic and neutron counting measurement. In this study, the resistivity of crystals is reported and the collected pulse height spectra are presented for devices irradiated with the 241AmBe neutron source. Long-term stability of the B2Se3 devices for neutron detection under continuous bias and without being under continuous bias was investigated and the results are reported. The B2Se3 devices showed response to thermal neutrons of the 241AmBe source.
Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng
2017-12-01
Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.
A low-complexity Reed-Solomon decoder using new key equation solver
NASA Astrophysics Data System (ADS)
Xie, Jun; Yuan, Songxin; Tu, Xiaodong; Zhang, Chongfu
2006-09-01
This paper presents a low-complexity parallel Reed-Solomon (RS) (255,239) decoder architecture using a novel pipelined variable stages recursive Modified Euclidean (ME) algorithm for optical communication. The pipelined four-parallel syndrome generator is proposed. The time multiplexing and resource sharing schemes are used in the novel recursive ME algorithm to reduce the logic gate count. The new key equation solver can be shared by two decoder macro. A new Chien search cell which doesn't need initialization is proposed in the paper. The proposed decoder can be used for 2.5Gb/s data rates device. The decoder is implemented in Altera' Stratixll device. The resource utilization is reduced about 40% comparing to the conventional method.
One-year outcomes of AquaLase cataract surgery.
Yoo, Sonia H; Bhatt, Anand B
2007-01-01
The authors report surgical experience and clinical outcomes up to 1 year postoperatively in patients who underwent cataract surgery with the AquaLase liquefaction device (Alcon Laboratories, Fort Worth, TX). The device is a handpiece option for use with Alcon's Infiniti Vision System that uses heated balanced saline solution micropulses to liquefy lenticular material. Twenty-seven eyes of 23 patients underwent cataract extraction with the use of the AquaLase liquefaction device. The average age of participants was 68 years, and the average nuclear sclerotic grade was 1.96 on a 4-point scale. Outcomes were judged by metrics such as visual acuity, inflammation, endothelial cell count, and postoperative posterior capsule opacification. At 30 days postoperatively, 78% of eyes had a best-corrected visual acuity of 20/20. Visual acuity was 20/25 or better 1 year postoperatively in 88% of patients without complications except conversion to ultrasound phacoemulsification for two dense cataracts.
Rajasuriar, Reena; Gouillou, Maelenn; Spelman, Tim; Read, Tim; Hoy, Jennifer; Law, Matthew; Cameron, Paul U.; Petoumenos, Kathy; Lewin, Sharon R.
2011-01-01
Background A small but significant number of patients do not achieve CD4 T-cell counts >500cells/µl despite years of suppressive cART. These patients remain at risk of AIDS and non-AIDS defining illnesses. The aim of this study was to identify clinical factors associated with CD4 T-cell recovery following long-term cART. Methods Patients with the following inclusion criteria were selected from the Australian HIV Observational Database (AHOD): cART as their first regimen initiated at CD4 T-cell count <500cells/µl, HIV RNA<500copies/ml after 6 months of cART and sustained for at least 12 months. The Cox proportional hazards model was used to identify determinants associated with time to achieve CD4 T-cell counts >500cells/µl and >200cells/µl. Results 501 patients were eligible for inclusion from AHOD (n = 2853). The median (IQR) age and baseline CD4 T-cell counts were 39 (32–47) years and 236 (130–350) cells/µl, respectively. A major strength of this study is the long follow-up duration, median (IQR) = 6.5(3–10) years. Most patients (80%) achieved CD4 T-cell counts >500cells/µl, but in 8%, this took >5 years. Among the patients who failed to reach a CD4 T-cell count >500cells/µl, 16% received cART for >10 years. In a multivariate analysis, faster time to achieve a CD4 T-cell count >500cells/µl was associated with higher baseline CD4 T-cell counts (p<0.001), younger age (p = 0.019) and treatment initiation with a protease inhibitor (PI)-based regimen (vs. non-nucleoside reverse transcriptase inhibitor, NNRTI; p = 0.043). Factors associated with achieving CD4 T-cell counts >200cells/µl included higher baseline CD4 T-cell count (p<0.001), not having a prior AIDS-defining illness (p = 0.018) and higher baseline HIV RNA (p<0.001). Conclusion The time taken to achieve a CD4 T-cell count >500cells/µl despite long-term cART is prolonged in a subset of patients in AHOD. Starting cART early with a PI-based regimen (vs. NNRTI-based regimen) is associated with more rapid recovery of a CD4 T-cell count >500cells/µl. PMID:21674057
Changing mortality risk associated with CD4 cell response to antiretroviral therapy in South Africa
Lawn, Stephen D.; Little, Francesca; Bekker, Linda-Gail; Kaplan, Richard; Campbel, Elizabeth; Orrell, Catherine; Wood, Robin
2013-01-01
Objective To determine the relationship between mortality risk and the CD4 cell response to antiretroviral therapy (ART). Design Observational community-based ART cohort in South Africa. Methods CD4 cell counts were measured 4 monthly, and deaths were prospectively ascertained. Cumulative person-time accrued within a range of updated CD4 cell count strata (CD4 cell-strata) was calculated and used to derive CD4 cell-stratified mortality rates. Results Patients (2423) (median baseline CD4 cell count of 105 cells/ml) were observed for up to 5 years of ART. One hundred and ninety-seven patients died during 3155 person years of observation. In multivariate analysis, mortality rate ratios associated with 0–49, 50–99, 100–199, 200–299, 300– 399, 400–499 and at least 500 cells/ml updated CD4 cell-strata were 11.6, 4.9, 2.6, 1.7, 1.5, 1.4 and 1.0, respectively. Analysis of CD4 cell count recovery permitted calculations of person-time accrued within these CD4 cell strata. Despite rapid immune recovery, high mortality in the first year of ART was related to the large proportion of person-time accrued within CD4 cell-strata less than 200 cells/ml. Moreover, patients with baseline CD4 cell counts less than 100 cells/ml had much higher cumulative mortality estimates at 1 and 4 years (11.6 and 16.7%) compared with those of patients with baseline counts of at least 100 cells/ml (5.2 and 9.5%) largely because of greater cumulative person-time at CD4 cell counts less than 200 cells/ml. Conclusion: Updated CD4 cell counts are the variable most strongly associated with mortality risk during ART. High cumulative mortality risk is associated with person-time accrued at low CD4 cell counts. National HIV programmes in resource-limited settings should be designed to minimize the time patients spend with CD4 cell counts less than 200 cells/ml both before and during ART. PMID:19114870
Imaging visible light with Medipix2.
Mac Raighne, Aaron; Brownlee, Colin; Gebert, Ulrike; Maneuski, Dzmitry; Milnes, James; O'Shea, Val; Rügheimer, Tilman K
2010-11-01
A need exists for high-speed single-photon counting optical imaging detectors. Single-photon counting high-speed detection of x rays is possible by using Medipix2 with pixelated silicon photodiodes. In this article, we report on a device that exploits the Medipix2 chip for optical imaging. The fabricated device is capable of imaging at >3000 frames/s over a 256×256 pixel matrix. The imaging performance of the detector device via the modulation transfer function is measured, and the presence of ion feedback and its degradation of the imaging properties are discussed.
Qin, Xi; Park, Sunyoung; Duffy, Simon P; Matthews, Kerryn; Ang, Richard R; Todenhöfer, Tilman; Abdi, Hamid; Azad, Arun; Bazov, Jenny; Chi, Kim N; Black, Peter C; Ma, Hongshen
2015-05-21
The enumeration and capture of circulating tumor cells (CTCs) are potentially of great clinical value as they offer a non-invasive means to access tumor materials to diagnose disease and monitor treatment efficacy. Conventional immunoenrichment of CTCs may fail to capture cells with low surface antigen expression. Micropore filtration presents a compelling label-free alternative that enriches CTCs using their biophysical rather than biochemical characteristics. However, this strategy is prone to clogging of the filter microstructure, which dramatically reduces the selectivity after processing large numbers of cells. Here, we use the resettable cell trap (RCT) mechanism to separate cells based on their size and deformability using an adjustable aperture that can be periodically cleared to prevent clogging. After separation, the output sample is stained and analyzed using multi-spectral analysis, which provides a more sensitive and unambiguous method to identify CTC biomarkers than traditional immunofluorescence. We tested the RCT device using blood samples obtained from 22 patients with metastatic castrate-resistant prostate cancer while comparing the results with the established CellSearch® system. The RCT mechanism was able to capture ≥5 CTCs in 18/22 (82%) patients with a mean count of 257 in 7.5 ml of whole blood, while the CellSearch system found ≥5 CTCs in 9/22 (41%) patients with a mean count of 25. The ~10× improvement in the CTC capture rate provides significantly more materials for subsequent analysis of these cells such as immunofluorescence, propagation by tissue culture, and genetic profiling.
Arraycount, an algorithm for automatic cell counting in microwell arrays.
Kachouie, Nezamoddin; Kang, Lifeng; Khademhosseini, Ali
2009-09-01
Microscale technologies have emerged as a powerful tool for studying and manipulating biological systems and miniaturizing experiments. However, the lack of software complementing these techniques has made it difficult to apply them for many high-throughput experiments. This work establishes Arraycount, an approach to automatically count cells in microwell arrays. The procedure consists of fluorescent microscope imaging of cells that are seeded in microwells of a microarray system and then analyzing images via computer to recognize the array and count cells inside each microwell. To start counting, green and red fluorescent images (representing live and dead cells, respectively) are extracted from the original image and processed separately. A template-matching algorithm is proposed in which pre-defined well and cell templates are matched against the red and green images to locate microwells and cells. Subsequently, local maxima in the correlation maps are determined and local maxima maps are thresholded. At the end, the software records the cell counts for each detected microwell on the original image in high-throughput. The automated counting was shown to be accurate compared with manual counting, with a difference of approximately 1-2 cells per microwell: based on cell concentration, the absolute difference between manual and automatic counting measurements was 2.5-13%.
Avian leucocyte counting using the hemocytometer
Dein, F.J.; Wilson, A.; Fischer, D.; Langenberg, P.
1994-01-01
Automated methods for counting leucocytes in avian blood are not available because of the presence of nucleated erythrocytes and thrombocytes. Therefore, total white blood cell counts are performed by hand using a hemocytometer. The Natt and Herrick and the Unopette methods are the most common stain and diluent preparations for this procedure. Replicate hemocytometer counts using these two methods were performed on blood from four birds of different species. Cells present in each square of the hemocytometer were counted. Counting cells in the corner, side, or center hemocytometer squares produced statistically equivalent results; counting four squares per chamber provided a result similar to that obtained by counting nine squares; and the Unopette method was more precise for hemocytometer counting than was the Natt and Herrick method. The Unopette method is easier to learn and perform but is an indirect process, utilizing the differential count from a stained smear. The Natt and Herrick method is a direct total count, but cell identification is more difficult.
Jokerst, Jesse V.; Floriano, Pierre N.; Christodoulides, Nicolaos; Simmons, Glennon W.; McDevitt, John T.
2010-01-01
Recent humanitarian efforts have led to the widespread release of antiretroviral drugs for the treatment of the more than 33 million HIV afflicted people living in resource-scarce settings. Here, the enumeration of CD4+ T lymphocytes is required to establish the level at which the immune system has been compromised. The gold standard method used in developed countries, based on flow cytometry, though widely accepted and accurate, is precluded from widespread use in resource-scarce settings due to its high expense, high technical requirements, difficulty in operation-maintenance and the lack of portability for these sophisticated laboratory-confined systems. As part of continuing efforts to develop practical diagnostic instrumentation, the integration of semiconductor nanocrystals (quantum dots, QDs) into a portable microfluidic-based lymphocyte capture and detection device is completed. This integrated system is capable of isolating and counting selected lymphocyte sub-populations (CD3+CD4+) from whole blood samples. By combining the unique optical properties of the QDs with the sample handling capabilities and cost effectiveness of novel microfluidic systems, a practical, portable lymphocyte measurement modality that correlates nicely with flow cytometry (R2 = 0.97) has been developed. This QD-based system reduces the optical requirements significantly relative to molecular fluorophores and the mini-CD4 counting device is projected to be suitable for use in both point-of-need and resource-scarce settings. PMID:19023471
Dittami, Gregory M; Sethi, Manju; Rabbitt, Richard D; Ayliffe, H Edward
2012-06-21
Particle and cell counting is used for a variety of applications including routine cell culture, hematological analysis, and industrial controls(1-5). A critical breakthrough in cell/particle counting technologies was the development of the Coulter technique by Wallace Coulter over 50 years ago. The technique involves the application of an electric field across a micron-sized aperture and hydrodynamically focusing single particles through the aperture. The resulting occlusion of the aperture by the particles yields a measurable change in electric impedance that can be directly and precisely correlated to cell size/volume. The recognition of the approach as the benchmark in cell/particle counting stems from the extraordinary precision and accuracy of its particle sizing and counts, particularly as compared to manual and imaging based technologies (accuracies on the order of 98% for Coulter counters versus 75-80% for manual and vision-based systems). This can be attributed to the fact that, unlike imaging-based approaches to cell counting, the Coulter Technique makes a true three-dimensional (3-D) measurement of cells/particles which dramatically reduces count interference from debris and clustering by calculating precise volumetric information about the cells/particles. Overall this provides a means for enumerating and sizing cells in a more accurate, less tedious, less time-consuming, and less subjective means than other counting techniques(6). Despite the prominence of the Coulter technique in cell counting, its widespread use in routine biological studies has been prohibitive due to the cost and size of traditional instruments. Although a less expensive Coulter-based instrument has been produced, it has limitations as compared to its more expensive counterparts in the correction for "coincidence events" in which two or more cells pass through the aperture and are measured simultaneously. Another limitation with existing Coulter technologies is the lack of metrics on the overall health of cell samples. Consequently, additional techniques must often be used in conjunction with Coulter counting to assess cell viability. This extends experimental setup time and cost since the traditional methods of viability assessment require cell staining and/or use of expensive and cumbersome equipment such as a flow cytometer. The Moxi Z mini automated cell counter, described here, is an ultra-small benchtop instrument that combines the accuracy of the Coulter Principle with a thin-film sensor technology to enable precise sizing and counting of particles ranging from 3-25 microns, depending on the cell counting cassette used. The M type cassette can be used to count particles from with average diameters of 4 - 25 microns (dynamic range 2 - 34 microns), and the Type S cassette can be used to count particles with and average diameter of 3 - 20 microns (dynamic range 2 - 26 microns). Since the system uses a volumetric measurement method, the 4-25 microns corresponds to a cell volume range of 34 - 8,180 fL and the 3 - 20 microns corresponds to a cell volume range of 14 - 4200 fL, which is relevant when non-spherical particles are being measured. To perform mammalian cell counts using the Moxi Z, the cells to be counted are first diluted with ORFLO or similar diluent. A cell counting cassette is inserted into the instrument, and the sample is loaded into the port of the cassette. Thousands of cells are pulled, single-file through a "Cell Sensing Zone" (CSZ) in the thin-film membrane over 8-15 seconds. Following the run, the instrument uses proprietary curve-fitting in conjunction with a proprietary software algorithm to provide coincidence event correction along with an assessment of overall culture health by determining the ratio of the number of cells in the population of interest to the total number of particles. The total particle counts include shrunken and broken down dead cells, as well as other debris and contaminants. The results are presented in histogram format with an automatic curve fit, with gates that can be adjusted manually as needed. Ultimately, the Moxi Z enables counting with a precision and accuracy comparable to a Coulter Z2, the current gold standard, while providing additional culture health information. Furthermore it achieves these results in less time, with a smaller footprint, with significantly easier operation and maintenance, and at a fraction of the cost of comparable technologies.
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
NASA Astrophysics Data System (ADS)
Stephenson, W. Kirk
2009-08-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes.
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions.
Toth, Lindsay P; Park, Susan; Springer, Cary M; Feyerabend, McKenzie D; Steeves, Jeremy A; Bassett, David R
2018-06-01
The purpose of this study was to determine the accuracy of 14-step counting methods under free-living conditions. Twelve adults (mean ± SD age, 35 ± 13 yr) wore a chest harness that held a GoPro camera pointed down at the feet during all waking hours for 1 d. The GoPro continuously recorded video of all steps taken throughout the day. Simultaneously, participants wore two StepWatch (SW) devices on each ankle (all programmed with different settings), one activPAL on each thigh, four devices at the waist (Fitbit Zip, Yamax Digi-Walker SW-200, New Lifestyles NL-2000, and ActiGraph GT9X (AG)), and two devices on the dominant and nondominant wrists (Fitbit Charge and AG). The GoPro videos were downloaded to a computer and researchers counted steps using a hand tally device, which served as the criterion method. The SW devices recorded between 95.3% and 102.8% of actual steps taken throughout the day (P > 0.05). Eleven step counting methods estimated less than 100% of actual steps; Fitbit Zip, Yamax Digi-Walker SW-200, and AG with the moving average vector magnitude algorithm on both wrists recorded 71% to 91% of steps (P > 0.05), whereas the activPAL, New Lifestyles NL-2000, and AG (without low-frequency extension (no-LFE), moving average vector magnitude) worn on the hip, and Fitbit Charge recorded 69% to 84% of steps (P < 0.05). Five methods estimated more than 100% of actual steps; AG (no-LFE) on both wrists recorded 109% to 122% of steps (P > 0.05), whereas the AG (LFE) on both wrists and the hip recorded 128% to 220% of steps (P < 0.05). Across all waking hours of 1 d, step counts differ between devices. The SW, regardless of settings, was the most accurate method of counting steps.
Chatura, K R; Sangeetha, S
2012-01-01
To assess the utility of a single stain for both mast cell count and bacillary index (BI), 50 skin-biopsie patients were stained with Fite-Faraco (FF) stain, viewed under oil immersion and BI calculated using the Ridley's logarithmic scale, and mast cells counted as the number of cells per mm2. Mean mast cell count per mm2 at the tuberculoid pole was lowest in TT 7.9 and highest in BT 14.23. At the lepromatous end, it was highest in BL 9.21, while in LL it was 8.23. Highest counts were seen in the borderline types overall. The correlation coefficient between histopathological diagnosis and BI is 0.822 which is a positive correlation to a significant degree. The correlation coefficient between histopathological diagnosis and mast cell count was found to be -0.17, which is a negative correlation but not to a significant degree. FF stain was utilised to visualise both bacilli for estimation of BI and mast cells for mast cell count, a seldom attempted feature in literature.
Egger, Sam; Petoumenos, Kathy; Kamarulzaman, Adeeba; Hoy, Jennifer; Sungkanuparph, Somnuek; Chuah, John; Falster, Kathleen; Zhou, Jialun; Law, Matthew G
2009-04-15
Random effects models were used to explore how the shape of CD4 cell count responses after commencing combination antiretroviral therapy (cART) develop over time and, in particular, the role of baseline and follow-up covariates. Patients in Asia Pacific HIV Observational Database who first commenced cART after January 1, 1997, and who had a baseline CD4 cell count and viral load measure and at least 1 follow-up measure between 6 and 24 months, were included. CD4 cell counts were determined at every 6-month period after the commencement of cART for up to 6 years. A total of 1638 patients fulfilled the inclusion criteria with a median follow-up time of 58 months. Lower post-cART mean CD4 cell counts were found to be associated with increasing age (P < 0.001), pre-cART hepatitis C coinfection (P = 0.038), prior AIDS (P = 0.019), baseline viral load < or equal to 100,000 copies per milliliter (P < 0.001), and the Asia Pacific region compared with Australia (P = 0.005). A highly significant 3-way interaction between the effects of time, baseline CD4 cell count, and post-cART viral burden (P < 0.0001) was demonstrated. Higher long-term mean CD4 cell counts were associated with lower baseline CD4 cell count and consistently undetectable viral loads. Among patients with consistently detectable viral load, CD4 cell counts seemed to converge for all baseline CD4 levels. Our analysis suggest that the long-term shape of post-cART CD4 cell count changes depends only on a 3-way interaction between baseline CD4 cell count, viral load response, and time.
Hwang, In-Sul; Kwon, Dae-Jin; Im, Gi-Sun; Tashima, Kazuya; Hochi, Shinichi; Hwang, Seongsoo
2016-01-01
Vitrification with the Cryotop device is the most promising technique for oocyte cryopreservation, but the high post-warming morphological survival of bovine oocytes does not guarantee high developmental competence after in vitro fertilization (IVF). This study was designed to examine achievement of normal fertilization in bovine oocytes vitrified-warmed with the Cryotop device. Oocytes were matured in vitro and vitrified-warmed after complete removal of the cumulus layers. Distribution of cortical granules (CGs) was assessed by Lens culinaris agglutinin (LCA) lectin staining. Ten hours after IVF, presumptive zygotes were analyzed for pronuclear formation. Day-8 blastocysts were harvested and stained with Hoechst-33342 for total cell counting. Both yield and mean cell number of the blastocysts were impaired by Cryotop vitrification. Incidence of polyspermic fertilization was three-times higher in vitrified oocytes compared to fresh oocytes. No difference in CG distribution was found between vitrified and fresh oocytes. Polyspermic fertilization induced in vitrified-warmed bovine oocytes may be one of the possible causes responsible for their low developmental potential.
Atilola, M A; Lumsden, J H; Rooke, F
1986-04-01
Synovial fluids collected from the stifle joints of 20 physically normal adult dogs were subjected to cytological examination. A total nucleated cell count was performed on each sample using both an electronic cell counter and a hemocytometer. The mean of the total counts done with the electronic counter was significantly higher (1008 cells/microL) than that obtained manually with the hemocytometer (848 cells/microL).
Mobile Device Accuracy for Step Counting Across Age Groups
Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W
2017-01-01
Background Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. Objective We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. Methods We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Results Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly undercounted steps for the group ranging from 65-84 years. Conclusions Our analysis shows that apart from the Fitbit Surge, most of the recent mobile devices we tested do not overcount or undercount steps in the 18-39-year-old age group, however some devices undercount steps in older age groups. This finding suggests that accuracy in step counting may be an issue with some popular wearable devices, and that age may be a factor in undercounting. These results are particularly important for clinical interventions using such devices and other activity trackers, in particular to balance energy requirements with energy expenditure in the context of a weight loss intervention program. PMID:28659255
Rastogi, Anshu; Pospísil, Pavel
2010-08-01
All living organisms emit spontaneous ultra-weak photon emission as a result of cellular metabolic processes. Exposure of living organisms to exogenous factors results in oxidative processes and enhancement in ultra-weak photon emission. Here, hydrogen peroxide (H(2)O(2)), as a strongly oxidizing molecule, was used to induce oxidative processes and enhance ultra-weak photon emission in human hand skin. The presented work intends to compare both spontaneous and peroxide-induced ultra-weak photon emission from the epidermal cells on the dorsal and the palm side of the hand. A highly sensitive photomultiplier tube and a charge-coupled device camera were used to detect ultra-weak photon emission from human hand skin. Spontaneous ultra-weak photon emission from the epidermal cells on the dorsal side of the hand was 4 counts/s. Topical application of 500 mM H(2)O(2) to the dorsal side of the hand caused enhancement in ultra-weak photon emission to 40 counts/s. Interestingly, both spontaneous and peroxide-induced ultra-weak photon emission from the epidermal cells on the palm side of the hand were observed to increase twice their values, i.e. 8 and 80 counts/s, respectively. Similarly, the two-dimensional image of ultra-weak photon emission observed after topical application of H(2)O(2) to human skin reveals that photon emission from the palm side exceeds the photon emission from the dorsal side of the hand. The results presented indicate that the ultra-weak photon emission originating from the epidermal cells on the dorsal and the palm side of the hand is related to the histological structure of the human hand skin. Ultra-weak photon emission is shown as a non-destructive technique for monitoring of oxidative processes in the epidermal cells of the human hand skin and as a diagnostic tool for skin diseases.
Optofluidic Fluorescent Imaging Cytometry on a Cell Phone
Zhu, Hongying; Mavandadi, Sam; Coskun, Ahmet F.; Yaglidere, Oguzhan; Ozcan, Aydogan
2012-01-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings. PMID:21774454
Optofluidic fluorescent imaging cytometry on a cell phone.
Zhu, Hongying; Mavandadi, Sam; Coskun, Ahmet F; Yaglidere, Oguzhan; Ozcan, Aydogan
2011-09-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical sciences. Cost-effective translation of these technologies to remote and resource-limited environments could create new opportunities especially for telemedicine applications. Toward this direction, here we demonstrate the integration of imaging cytometry and fluorescent microscopy on a cell phone using a compact, lightweight, and cost-effective optofluidic attachment. In this cell-phone-based optofluidic imaging cytometry platform, fluorescently labeled particles or cells of interest are continuously delivered to our imaging volume through a disposable microfluidic channel that is positioned above the existing camera unit of the cell phone. The same microfluidic device also acts as a multilayered optofluidic waveguide and efficiently guides our excitation light, which is butt-coupled from the side facets of our microfluidic channel using inexpensive light-emitting diodes. Since the excitation of the sample volume occurs through guided waves that propagate perpendicular to the detection path, our cell-phone camera can record fluorescent movies of the specimens as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the target solution of interest. We tested the performance of our cell-phone-based imaging cytometer by measuring the density of white blood cells in human blood samples, which provided a decent match to a commercially available hematology analyzer. We further characterized the imaging quality of the same platform to demonstrate a spatial resolution of ~2 μm. This cell-phone-enabled optofluidic imaging flow cytometer could especially be useful for rapid and sensitive imaging of bodily fluids for conducting various cell counts (e.g., toward monitoring of HIV+ patients) or rare cell analysis as well as for screening of water quality in remote and resource-poor settings.
Single photon detection using Geiger mode CMOS avalanche photodiodes
NASA Astrophysics Data System (ADS)
Lawrence, William G.; Stapels, Christopher; Augustine, Frank L.; Christian, James F.
2005-10-01
Geiger mode Avalanche Photodiodes fabricated using complementary metal-oxide-semiconductor (CMOS) fabrication technology combine high sensitivity detectors with pixel-level auxiliary circuitry. Radiation Monitoring Devices has successfully implemented CMOS manufacturing techniques to develop prototype detectors with active diameters ranging from 5 to 60 microns and measured detection efficiencies of up to 60%. CMOS active quenching circuits are included in the pixel layout. The actively quenched pixels have a quenching time less than 30 ns and a maximum count rate greater than 10 MHz. The actively quenched Geiger mode avalanche photodiode (GPD) has linear response at room temperature over six orders of magnitude. When operating in Geiger mode, these GPDs act as single photon-counting detectors that produce a digital output pulse for each photon with no associated read noise. Thermoelectrically cooled detectors have less than 1 Hz dark counts. The detection efficiency, dark count rate, and after-pulsing of two different pixel designs are measured and demonstrate the differences in the device operation. Additional applications for these devices include nuclear imaging and replacement of photomultiplier tubes in dosimeters.
Dysmegakaryocytopoiesis and maintaining platelet count in patients with plasma cell neoplasm.
Mair, Yasmin; Zheng, Yan; Cai, Donghong
2013-05-01
Dysmegakaryocytopoiesis in patients with the plasma cell neoplasm (PCN) is rarely discussed in the literature. The puzzling phenomenon, which PCN patients maintaining normal platelet count even when the marrow is mostly replaced by plasma cells, is hardly explored. This study was aimed to determine the frequency of dysmegakaryocytopoiesis in PCN and the relationships between bone marrow (BM) plasma cell percentage, plasma cell immunomarkers, the severity of dysmegakaryocytopoiesis, and peripheral blood platelet count in PCN. We randomly selected 16 cases of PCN, among which 4 were with monoclonal gammopathy of undetermined significance and 12 were with plasma cell myeloma. OUR STUDY SHOWED THAT: (1) Dysmegakaryocytopoiesis was present in all the selected cases of PCN and its severity was not correlated with the percentage of the plasma cells in BM; (2) almost all patients maintained normal platelet count even when BM was mostly replaced by plasma cells; (3) immunomarkers of the neoplastic plasma cells were not associated with dysmegakaryocytopoiesis or maintaining of platelet count. The possible mechanisms behind dysmegakaryocytopoiesis and maintaining of platelet count were also discussed. Despite the universal presence of dysmegakaryocytopoiesis in PCN, the platelet count is maintained at normal range.
A cost effective 5΄ selective single cell transcriptome profiling approach with improved UMI design
Arguel, Marie-Jeanne; LeBrigand, Kevin; Paquet, Agnès; Ruiz García, Sandra; Zaragosi, Laure-Emmanuelle; Waldmann, Rainer
2017-01-01
Abstract Single cell RNA sequencing approaches are instrumental in studies of cell-to-cell variability. 5΄ selective transcriptome profiling approaches allow simultaneous definition of the transcription start size and have advantages over 3΄ selective approaches which just provide internal sequences close to the 3΄ end. The only currently existing 5΄ selective approach requires costly and labor intensive fragmentation and cell barcoding after cDNA amplification. We developed an optimized 5΄ selective workflow where all the cell indexing is done prior to fragmentation. With our protocol, cell indexing can be performed in the Fluidigm C1 microfluidic device, resulting in a significant reduction of cost and labor. We also designed optimized unique molecular identifiers that show less sequence bias and vulnerability towards sequencing errors resulting in an improved accuracy of molecule counting. We provide comprehensive experimental workflows for Illumina and Ion Proton sequencers that allow single cell sequencing in a cost range comparable to qPCR assays. PMID:27940562
Martyniak, Brian; Bolton, Jason; Kuksin, Dmitry; Shahin, Suzanne M; Chan, Leo Li-Ying
2017-01-01
Brettanomyces spp. can present unique cell morphologies comprised of excessive pseudohyphae and budding, leading to difficulties in enumerating cells. The current cell counting methods include manual counting of methylene blue-stained yeasts or measuring optical densities using a spectrophotometer. However, manual counting can be time-consuming and has high operator-dependent variations due to subjectivity. Optical density measurement can also introduce uncertainties where instead of individual cells counted, an average of a cell population is measured. In contrast, by utilizing the fluorescence capability of an image cytometer to detect acridine orange and propidium iodide viability dyes, individual cell nuclei can be counted directly in the pseudohyphae chains, which can improve the accuracy and efficiency of cell counting, as well as eliminating the subjectivity from manual counting. In this work, two experiments were performed to demonstrate the capability of Cellometer image cytometer to monitor Brettanomyces concentrations, viabilities, and budding/pseudohyphae percentages. First, a yeast propagation experiment was conducted to optimize software counting parameters for monitoring the growth of Brettanomyces clausenii, Brettanomyces bruxellensis, and Brettanomyces lambicus, which showed increasing cell concentrations, and varying pseudohyphae percentages. The pseudohyphae formed during propagation were counted either as multiple nuclei or a single multi-nuclei organism, where the results of counting the yeast as a single multi-nuclei organism were directly compared to manual counting. Second, a yeast fermentation experiment was conducted to demonstrate that the proposed image cytometric analysis method can monitor the growth pattern of B. lambicus and B. clausenii during beer fermentation. The results from both experiments displayed different growth patterns, viability, and budding/pseudohyphae percentages for each Brettanomyces species. The proposed Cellometer image cytometry method can improve efficiency and eliminate operator-dependent variations of cell counting compared with the traditional methods, which can potentially improve the quality of beverage products employing Brettanomyces yeasts.
Winkelman, James W; Tanasijevic, Milenko J; Zahniser, David J
2017-08-01
- A novel automated slide-based approach to the complete blood count and white blood cell differential count is introduced. - To present proof of concept for an image-based approach to complete blood count, based on a new slide preparation technique. A preliminary data comparison with the current flow-based technology is shown. - A prototype instrument uses a proprietary method and technology to deposit a precise volume of undiluted peripheral whole blood in a monolayer onto a glass microscope slide so that every cell can be distinguished, counted, and imaged. The slide is stained, and then multispectral image analysis is used to measure the complete blood count parameters. Images from a 600-cell white blood cell differential count, as well as 5000 red blood cells and a variable number of platelets, that are present in 600 high-power fields are made available for a technologist to view on a computer screen. An initial comparison of the basic complete blood count parameters was performed, comparing 1857 specimens on both the new instrument and a flow-based hematology analyzer. - Excellent correlations were obtained between the prototype instrument and a flow-based system. The primary parameters of white blood cell, red blood cell, and platelet counts resulted in correlation coefficients (r) of 0.99, 0.99, and 0.98, respectively. Other indices included hemoglobin (r = 0.99), hematocrit (r = 0.99), mean cellular volume (r = 0.90), mean corpuscular hemoglobin (r = 0.97), and mean platelet volume (r = 0.87). For the automated white blood cell differential counts, r values were calculated for neutrophils (r = 0.98), lymphocytes (r = 0.97), monocytes (r = 0.76), eosinophils (r = 0.96), and basophils (r = 0.63). - Quantitative results for components of the complete blood count and automated white blood cell differential count can be developed by image analysis of a monolayer preparation of a known volume of peripheral blood.
[Correlation between red blood cell count and liver function status].
Xie, Xiaomeng; Wang, Leijie; Yao, Mingjie; Wen, Xiajie; Chen, Xiangmei; You, Hong; Jia, Jidong; Zhao, Jingmin; Lu, Fengmin
2016-02-01
To investigate the changes in red blood cell count in patients with different liver diseases and the correlation between red blood cell count and degree of liver damage. The clinical data of 1427 patients with primary liver cancer, 172 patients with liver cirrhosis, and 185 patients with hepatitis were collected, and the Child-Pugh class was determined for all patients. The differences in red blood cell count between patients with different liver diseases were retrospectively analyzed, and the correlation between red blood cell count and liver function status was investigated. The Mann-Whitney U test, Kruskal-Wallis H test, rank sum test, Spearman rank sum correlation test, and chi-square test were performed for different types of data. Red blood cell count showed significant differences between patients with chronic hepatitis, liver cancer, and liver cirrhosis and was highest in patients with chronic hepatitis and lowest in patients with liver cirrhosis (P < 0.05). In the patients with liver cirrhosis, red blood cell count tended to decrease in patients with a higher Child-Pugh class (P < 0.05). For patients with liver cirrhosis, red blood cell count can reflect the degree of liver damage, which may contribute to an improved liver function prediction model for these patients.
Lower white blood cell counts in elite athletes training for highly aerobic sports.
Horn, P L; Pyne, D B; Hopkins, W G; Barnes, C J
2010-11-01
White cell counts at rest might be lower in athletes participating in selected endurance-type sports. Here, we analysed blood tests of elite athletes collected over a 10-year period. Reference ranges were established for 14 female and 14 male sports involving 3,679 samples from 937 females and 4,654 samples from 1,310 males. Total white blood cell counts and counts of neutrophils, lymphocytes and monocytes were quantified. Each sport was scaled (1-5) for its perceived metabolic stress (aerobic-anaerobic) and mechanical stress (concentric-eccentric) by 13 sports physiologists. Substantially lower total white cell and neutrophil counts were observed in aerobic sports of cycling and triathlon (~16% of test results below the normal reference range) compared with team or skill-based sports such as water polo, cricket and volleyball. Mechanical stress of sports had less effect on the distribution of cell counts. The lower white cell counts in athletes in aerobic sports probably represent an adaptive response, not underlying pathology.
Getting something out of nothing in the measurement-device-independent quantum key distribution
NASA Astrophysics Data System (ADS)
Tan, Yong-Gang; Cai, Qing-Yu; Yang, Hai-Feng; Hu, Yao-Hua
2015-11-01
Because of the monogamy of entanglement, the measurement-device-independent quantum key distribution is immune to the side-information leaking of the measurement devices. When the correlated measurement outcomes are generated from the dark counts, no entanglement is actually obtained. However, secure key bits can still be proven to be generated from these measurement outcomes. Especially, we will give numerical studies on the contributions of dark counts to the key generation rate in practical decoy state MDI-QKD where a signal source, a weaker decoy source and a vacuum decoy source are used by either legitimate key distributer.
Kim, Seo Yeon; Lee, Hyewon; Han, Mi-Soon; Shim, Hyoeun; Eom, Hyeon-Seok; Park, Boram; Kong, Sun-Young
2016-09-01
Reconstitution of the immune system after allogeneic hematopoietic stem cell transplantation (allo-HSCT) plays an important role in post-transplant outcomes. However, the clinical relevance of the lymphocyte subset (LST) counts to transplant-related complications and survival outcomes after allo-HSCT has not been fully elucidated. A total of 70 patients who had undergone allo-HSCT from 2007 to 2013, with LST results both 7 days before conditioning and 30 or 90 days after allo-HSCT were included. The LST counts in the peripheral blood were determined using 6-color flow cytometry. Clinical information, including transplant-related events during the first 100 days after allo-HSCT, was reviewed, and any association between these events and LST was analyzed. At 30 days after allo-HSCT, the CD4 + T-cell (P = .009) and B-cell (P = .035) counts were lower and the natural killer (NK) cell count was greater (P < .001) than before conditioning. The CD8 + T-cell (P = .001) and NK cell (P < .001) counts were high 90 days after transplantation. The hazard ratios for a low NK cell count on days 30 and 90 for acute graft-versus-host disease were 6.22 and 14.67, respectively. Patients with low NK cell counts at 30 and 90 days after allo-HSCT had poorer overall survival (P = .043 and P = .028, respectively) and greater nonrelapse mortality (P = .036 and P = .033, respectively). A low NK cell count on day 30 was still prognostic for overall survival (P = .039) on multivariable analysis. NK cell counts after allo-HSCT, especially on day 30, were predictive of acute graft-versus-host disease, nonrelapse mortality, and survival. Serial lymphocyte subset analysis can be used to identify and treat patients at risk during the early period after allo-HSCT. Copyright © 2016 Elsevier Inc. All rights reserved.
Koyama, Kento; Hokunan, Hidekazu; Hasegawa, Mayumi; Kawamura, Shuso; Koseki, Shigenobu
2016-12-01
We investigated a bacterial sample preparation procedure for single-cell studies. In the present study, we examined whether single bacterial cells obtained via 10-fold dilution followed a theoretical Poisson distribution. Four serotypes of Salmonella enterica, three serotypes of enterohaemorrhagic Escherichia coli and one serotype of Listeria monocytogenes were used as sample bacteria. An inoculum of each serotype was prepared via a 10-fold dilution series to obtain bacterial cell counts with mean values of one or two. To determine whether the experimentally obtained bacterial cell counts follow a theoretical Poisson distribution, a likelihood ratio test between the experimentally obtained cell counts and Poisson distribution which parameter estimated by maximum likelihood estimation (MLE) was conducted. The bacterial cell counts of each serotype sufficiently followed a Poisson distribution. Furthermore, to examine the validity of the parameters of Poisson distribution from experimentally obtained bacterial cell counts, we compared these with the parameters of a Poisson distribution that were estimated using random number generation via computer simulation. The Poisson distribution parameters experimentally obtained from bacterial cell counts were within the range of the parameters estimated using a computer simulation. These results demonstrate that the bacterial cell counts of each serotype obtained via 10-fold dilution followed a Poisson distribution. The fact that the frequency of bacterial cell counts follows a Poisson distribution at low number would be applied to some single-cell studies with a few bacterial cells. In particular, the procedure presented in this study enables us to develop an inactivation model at the single-cell level that can estimate the variability of survival bacterial numbers during the bacterial death process. Copyright © 2016 Elsevier Ltd. All rights reserved.
Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone
Zhu, Hongying; Ozcan, Aydogan
2013-01-01
Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. ~ 10 μm over a very large field-of-view of ~ 81 mm2. This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water. PMID:23603893
Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone.
Zhu, Hongying; Ozcan, Aydogan
2013-04-11
Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. - 10 μm over a very large field-of-view of - 81 mm(2). This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water.
Ammersbach, Mélanie; Beaufrère, Hugues; Gionet Rollick, Annick; Tully, Thomas
2015-03-01
While hematologic reference intervals (RI) are available for multiple raptorial species of the order Accipitriformes and Falconiformes, there is a lack of valuable hematologic information in Strigiformes that can be used for diagnostic and health monitoring purposes. The objective was to report RI in Strigiformes for hematologic variables and to assess agreement between manual cell counting techniques. A multi-center prospective study was designed to assess hematologic RI and blood cell morphology in owl species. Samples were collected from individuals representing 13 Strigiformes species, including Great Horned Owl, Snowy Owl, Eurasian Eagle Owl, Barred Owl, Great Gray Owl, Ural Owl, Northern Saw-Whet Owls, Northern Hawk Owl, Spectacled Owl, Barn Owl, Eastern Screech Owl, Long-Eared Owl, and Short-Eared Owl. Red blood cell count was determined manually using a hemocytometer. White blood cell count was determined using 3 manual counting techniques: (1) phloxine B technique, (2) Natt and Herrick technique, and (3) estimation from the smear. Differential counts and blood cell morphology were determined on smears. Reference intervals were determined and agreement between methods was calculated. Important species-specific differences were observed in blood cell counts and granulocyte morphology. Differences in WBC count between species did not appear to be predictable based on phylogenetic relationships. Overall, most boreal owl species exhibited a lower WBC count than other species. Important disagreements were found between different manual WBC counting techniques. Disagreements observed between manual counting techniques suggest that technique-specific RI should be used in Strigiformes. © 2015 American Society for Veterinary Clinical Pathology.
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
ERIC Educational Resources Information Center
Stephenson, W. Kirk
2009-01-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)
Ford, Nathan; Shubber, Zara; Jarvis, Joseph N; Chiller, Tom; Greene, Greg; Migone, Chantal; Vitoria, Marco; Doherty, Meg; Meintjes, Graeme
2018-03-04
Current guidelines recommend screening all people living with human immunodeficiency virus (PLHIV) who have a CD4 count ≤100 cells/µL for cryptococcal antigen (CrAg) to identify those patients who could benefit from preemptive fluconazole treatment prior to the onset of meningitis. We conducted a systematic review to assess the prevalence of CrAg positivity at different CD4 cell counts. We searched 4 databases and abstracts from 3 conferences up to 1 September 2017 for studies reporting prevalence of CrAg positivity according to CD4 cell count strata. Prevalence estimates were pooled using random effects models. Sixty studies met our inclusion criteria. The pooled prevalence of cryptococcal antigenemia was 6.5% (95% confidence interval [CI], 5.7%-7.3%; 54 studies) among patients with CD4 count ≤100 cells/µL and 2.0% (95% CI, 1.2%-2.7%; 21 studies) among patients with CD4 count 101-200 cells/µL. Twenty-one studies provided sufficient information to compare CrAg prevalence per strata; overall, 18.6% (95% CI, 15.4%-22.2%) of the CrAg-positive cases identified at ≤200 cells/µL (n = 11823) were identified among individuals with a CD4 count 101-200 cells/µL. CrAg prevalence was higher among inpatients (9.8% [95% CI, 4.0%-15.5%]) compared with outpatients (6.3% [95% CI, 5.3%-7.4%]). The findings of this review support current recommendations to screen all PLHIV who have a CD4 count ≤100 cells/µL for CrAg and suggest that screening may be considered at CD4 cell count ≤200 cells/µL.
Baudart, Julia; Coallier, Josée; Laurent, Patrick; Prévost, Michèle
2002-01-01
Water quality assessment involves the specific, sensitive, and rapid detection of bacterial indicators and pathogens in water samples, including viable but nonculturable (VBNC) cells. This work evaluates the specificity and sensitivity of a new method which combines a fluorescent in situ hybridization (FISH) approach with a physiological assay (direct viable count [DVC]) for the direct enumeration, at the single-cell level, of highly diluted viable cells of members of the family Enterobacteriaceae in freshwater and drinking water after membrane filtration. The approach (DVC-FISH) uses a new direct detection device, the laser scanning cytometer (Scan RDI). Combining the DVC-FISH method on a membrane with Scan RDI detection makes it possible to detect as few as one targeted cell in approximately 108 nontargeted cells spread over the membrane. The ability of this new approach to detect and enumerate VBNC enterobacterial cells in freshwater and drinking water distribution systems was investigated and is discussed. PMID:12324357
Design and evaluation of a nondestructive fissile assay device for HTGR fuel samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNeany, S. R.; Knoll, R. W.; Jenkins, J. D.
1979-02-01
Nondestructive assay of fissile material plays an important role in nuclear fuel processing facilities. Information for product quality control, plant criticality safety, and nuclear materials accountability can be obtained from assay devices. All of this is necessary for a safe, efficient, and orderly operation of a production plant. Presented here is a design description and an operational evaluation of a device developed to nondestructively assay small samples of High-Temperature Gas-Cooled Reactor (HTGR) fuel. The measurement technique employed consists in thermal-neutron irradiation of a sample followed by pneumatic transfer to a high-efficiency neutron detector where delayed neutrons are counted. In general,more » samples undergo several irradiation and count cycles during a measurement. The total number of delayed-neutron counts accumulated is translated into grams of fissile mass through comparison with the counts accumulated in an identical irradiation and count sequence of calibration standards. Successful operation of the device through many experiments over a one-year period indicates high operational reliability. Tests of assay precision show this to be better than 0.25% for measurements of 10 min. Assay biases may be encountered if calibration standards are not representative of unknown samples, but reasonable care in construction and control of standards should lead to no more than 0.2% bias in the measurements. Nondestructive fissile assay of HTGR fuel samples by thermal-neutron irradiation and delayed-neutron detection has been demonstrated to be a rapid and accurate analysis technique. However, careful attention and control must be given to calibration standards to see that they remain representative of unknown samples.« less
Godon, Alban; Genevieve, Franck; Marteau-Tessier, Anne; Zandecki, Marc
2012-01-01
Several situations lead to abnormal haemoglobin measurement or to abnormal red blood cells (RBC) counts, including hyperlipemias, agglutinins and cryoglobulins, haemolysis, or elevated white blood cells (WBC) counts. Mean (red) cell volume may be also subject to spurious determination, because of agglutinins (mainly cold), high blood glucose level, natremia, anticoagulants in excess and at times technological considerations. Abnormality related to one measured parameter eventually leads to abnormal calculated RBC indices: mean cell haemoglobin content is certainly the most important RBC parameter to consider, maybe as important as flags generated by the haematology analysers (HA) themselves. In many circumstances, several of the measured parameters from cell blood counts (CBC) may be altered, and the discovery of a spurious change on one parameter frequently means that the validity of other parameters should be considered. Sensitive flags allow now the identification of several spurious counts, but only the most sophisticated HA have optimal flagging, and simpler ones, especially those without any WBC differential scattergram, do not share the same capacity to detect abnormal results. Reticulocytes are integrated into the CBC in many HA, and several situations may lead to abnormal counts, including abnormal gating, interference with intraerythrocytic particles, erythroblastosis or high WBC counts.
A new device for dynamic sampling of radon in air
NASA Astrophysics Data System (ADS)
Lozano, J. C.; Escobar, V. Gómez; Tomé, F. Vera
2000-08-01
A new system is proposed for the active sampling of radon in air, based on the well-known property of activated charcoal to retain radon. Two identical carbon-activated cartridges arranged in series remove the radon from the air being sampled. The air passes first through a desiccant cell and then the carbon cartridges for short sampling times using a low-flow pump. The alpha activity for each cartridge is determined by a liquid scintillation counting system. The cartridge is placed in a holder into a vial that also contains the appropriate amount of scintillation cocktail, in a way that avoids direct contact between cocktail and charcoal. Once dynamic equilibrium between the phases has been reached, the vials can be counted. Optimum sampling conditions concerning flow rates and sampling times are determined. Using those conditions, the method was applied to environmental samples, straightforwardly providing good results for very different levels of activity.
Final Technical Report- Radiation Hard Tight Pitch GaInP SPAD Arrays for High Energy Physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harmon, Eric S.
The specialized photodetectors used in high energy physics experiments often need to remain extremely sensitive for years despite radiation induced damage caused by the constant bombardment of high energy particles. To solve this problem, LightSpin Technologies, Inc. in collaboration with Prof. Bradley Cox and the University of Virginia is developing radiation-hard GaInP photodetectors which are projected to be extraordinarily radiation hard, theoretically capable of withstanding a 100,000-fold higher radiation dose than silicon. In this Phase I SBIR project, LightSpin investigated the performance and radiation hardness of fifth generation GaInP SPAD arrays. These fifth generation devices used a new planar processingmore » approach that enables very tight pitch arrays to be produced. High performance devices with SPAD pitches of 11, 15, and 25 μm were successfully demonstrated, which greatly increased the dynamic range and maximum count rate of the devices. High maximum count rates are critical when considering radiation hardness, since radiation damage causes a proportional increase in the dark count rate, causing SPAD arrays with low maximum count rates (large SPAD pitches) to fail. These GaInP SPAD array Photomultiplier Chips™ were irradiated with protons, electrons, and neutrons. Initial irradiation results were disappointing, with the post-irradiation devices exhibiting excessively high dark currents. The degradation was traced to surface leakage currents that were largely eliminated through the use of trenches etched around the exterior of the Photomultiplier Chip™ (not between SPAD elements). A second round of irradiations on Photomultiplier Chips™ with trenches proved substantially more successful, with post-irradiation dark currents remaining relatively low, though dark count rates were observed to increase at the highest doses. Preliminary analysis of the post-irradiation devices is promising … many of the irradiated Photomultiplier Chips™ still exhibit good gain characteristics after 1E12/cm 2 – 1E13/cm 2 doses and have apparent dark count rates that are lower than the apparent dark count rates published for irradiation of silicon SPAD arrays (silicon photomultipliers or SiPMs). Some post-irradiation results are still pending because the samples will still too radioactive to be shipped back from the irradiation facility for post-irradiation testing.« less
Somatic cell counts in bulk milk and their importance for milk processing
NASA Astrophysics Data System (ADS)
Savić, N. R.; Mikulec, D. P.; Radovanović, R. S.
2017-09-01
Bulk tank milk somatic cell counts are the indicator of the mammary gland health in the dairy herds and may be regarded as an indirect measure of milk quality. Elevated somatic cell counts are correlated with changes in milk composition The aim of this study was to assess the somatic cell counts that significantly affect the quality of milk and dairy products. We examined the somatic cell counts in bulk tank milk samples from 38 farms during the period of 6 months, from December to the May of the next year. The flow cytometry, Fossomatic was used for determination of somatic cell counts. In the same samples content of total proteins and lactose was determined by Milcoscan. Our results showed that average values for bulk tank milk samples were 273,605/ml from morning milking and 292,895/ml from evening milking. The average values for total proteins content from morning and evening milking are 3,31 and 3,34%, respectively. The average values for lactose content from morning and evening milking are 4,56 and 4,63%, respectively. The highest somatic cell count (516,000/ml) was detected in bulk tank milk sample from evening milk in the Winter and the lowest content of lactose was 4,46%. Our results showed that obtained values for bulk tank milk somatic cell counts did not significantly affected the content of total proteins and lactose.
Messiaen, Peter E; Cuyx, Senne; Dejagere, Tom; van der Hilst, Jeroen C
2017-04-01
In recent years, the incidence of Pneumocystis jirovecii pneumonia (PJP) has increased in immunocompromised patients without human immunodeficiency virus (HIV) infection. Chemoprophylaxis with trimethoprim-sulfamethoxazole (TMP-SMX) is highly effective in preventing PJP in both HIV-positive and -seronegative patients. In HIV-positive patients, the risk of PJP is strongly correlated with decreased CD4 cell count. The role of CD4 cell count in the pathogenesis of PJP in non-HIV immunocompromised patients is less well studied. For most immunosuppressive conditions, no clear guidelines indicate whether to start TMP-SMX. We conducted a systematic literature review with the aim to provide a comprehensive overview on the role of CD4 cell counts in managing the risk of PJP in HIV-seronegative patients. Of the 63 individual studies retrieved, 14 studies report on CD4 cell counts in a variety of immunosuppressive conditions. CD4 cell count were <200/μL in 73.1% of the patients. CD4 cell count <200/μL is a sensitive biomarker to identify non-HIV immunocompromised patients who are at risk for PJP. Measuring CD4 cell counts could help clinicians identify patients who may benefit from TMP-SMX prophylaxis. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
El-Azizi, Mohamed; Farag, Noha; Khardori, Nancy
2015-04-03
Candida albicans is a common cause of a variety of superficial and invasive disseminated infections the majority of which are associated with biofilm growth on implanted devices. The aim of the study is to evaluate the activity of amphotericin B and voriconazole against the biofilm and the biofilm-dispersed cells of Candida albicans using a newly developed in vitro pharmacokinetic model which simulates the clinical situation when the antifungal agents are administered intermittently. RPMI medium containing 1-5 X 10(6) CFU/ml of C. albicans was continuously delivered to the device at 30 ml/h for 2 hours. The planktonic cells were removed and biofilms on the catheter were kept under continuous flow of RPMI medium at 10 ml/h. Five doses of amphotericin B or voriconazole were delivered to 2, 5 and 10 day-old biofilms at initial concentrations (2 and 3 μg/ml respectively) that were exponentially diluted. Dispersed cells in effluents from the device were counted and the adherent cells on the catheter were evaluated after 48 h of the last dose. The minimum inhibitory concentration of voriconazole and amphotericin B against the tested isolate was 0.0325 and 0.25 μg/ml respectively. Amphotericin B significantly reduced the dispersion of C. albicans cells from the biofilm. The log10 reduction in the dispersed cells was 2.54-3.54, 2.30-3.55, and 1.94-2.50 following addition of 5 doses of amphotericin B to 2-, 5- and 10-day old biofilms respectively. The number of the viable cells within the biofilm was reduced by 18 (±7.63), 5 and 4% following addition of the 5 doses of amphotericin B to the biofilms respectively. Voriconazole showed no significant effect on the viability of C. albicans within the biofilm. Both antifungal agents failed to eradicate C. albicans biofilm or stop cell dispersion from them and the resistance progressed with maturation of the biofilm. These findings go along with the need for removal of devices in spite of antifungal therapy in patients with device-related infection. This is the first study which investigates the effects of antifungal agents on the biofilm and biofilm-dispersion of C. albicans in an in vitro pharmacokinetic biofilm model.
Active transport improves the precision of linear long distance molecular signalling
NASA Astrophysics Data System (ADS)
Godec, Aljaž; Metzler, Ralf
2016-09-01
Molecular signalling in living cells occurs at low copy numbers and is thereby inherently limited by the noise imposed by thermal diffusion. The precision at which biochemical receptors can count signalling molecules is intimately related to the noise correlation time. In addition to passive thermal diffusion, messenger RNA and vesicle-engulfed signalling molecules can transiently bind to molecular motors and are actively transported across biological cells. Active transport is most beneficial when trafficking occurs over large distances, for instance up to the order of 1 metre in neurons. Here we explain how intermittent active transport allows for faster equilibration upon a change in concentration triggered by biochemical stimuli. Moreover, we show how intermittent active excursions induce qualitative changes in the noise in effectively one-dimensional systems such as dendrites. Thereby they allow for significantly improved signalling precision in the sense of a smaller relative deviation in the concentration read-out by the receptor. On the basis of linear response theory we derive the exact mean field precision limit for counting actively transported molecules. We explain how intermittent active excursions disrupt the recurrence in the molecular motion, thereby facilitating improved signalling accuracy. Our results provide a deeper understanding of how recurrence affects molecular signalling precision in biological cells and novel medical-diagnostic devices.
Lai, Chieh-Hsien; Wu, Sih-Rong; Pang, Jen-Chieh; Ramireddy, Latha; Chiang, Yu-Cheng; Lin, Chien-Ku; Tsen, Hau-Yang
2017-07-01
The purpose of this study is to evaluate the efficiency of using propidium monoazide (PMA) real-time quantitative polymerase chain reaction (qPCR) to count the viable cells of Lactobacillus gasseri and Lactobacillus salivarius in probiotic products. Based on the internal transcription spacer and 23S rRNA genes, two primer sets specific for these two Lactobacillus species were designed. For a probiotic product, the total deMan Rogosa Sharpe plate count was 8.65±0.69 log CFU/g, while for qPCR, the cell counts of L. gasseri and L. salivarius were 8.39±0.14 log CFU/g and 8.57±0.24 log CFU/g, respectively. Under the same conditions, for its heat-killed product, qPCR counts for L. gasseri and L. salivarius were 6.70±0.16 log cells/g and 7.67±0.20 log cells/g, while PMA-qPCR counts were 5.33±0.18 log cells/g and 5.05±0.23 log cells/g, respectively. For cell dilutions with a viable cell count of 8.5 log CFU/mL for L. gasseri and L. salivarius, after heat killing, the PMA-qPCR count for both Lactobacillus species was near 5.5 log cells/mL. When the PMA-qPCR counts of these cell dilutions were compared before and after heat killing, although some DNA might be lost during the heat killing, significant qPCR signals from dead cells, i.e., about 4-5 log cells/mL, could not be reduced by PMA treatment. Increasing PMA concentrations from 100 μM to 200 μM or light exposure time from 5 minutes to 15 minutes had no or, if any, only minor effect on the reduction of qPCR signals from their dead cells. Thus, to differentiate viable lactic acid bacterial cells from dead cells using the PMA-qPCR method, the efficiency of PMA to reduce the qPCR signals from dead cells should be notable. Copyright © 2016. Published by Elsevier B.V.
Campton, Daniel E; Ramirez, Arturo B; Nordberg, Joshua J; Drovetto, Nick; Clein, Alisa C; Varshavskaya, Paulina; Friemel, Barry H; Quarre, Steve; Breman, Amy; Dorschner, Michael; Blau, Sibel; Blau, C Anthony; Sabath, Daniel E; Stilwell, Jackie L; Kaldjian, Eric P
2015-05-06
Circulating tumor cells (CTCs) are malignant cells that have migrated from solid cancers into the blood, where they are typically present in rare numbers. There is great interest in using CTCs to monitor response to therapies, to identify clinically actionable biomarkers, and to provide a non-invasive window on the molecular state of a tumor. Here we characterize the performance of the AccuCyte®--CyteFinder® system, a comprehensive, reproducible and highly sensitive platform for collecting, identifying and retrieving individual CTCs from microscopic slides for molecular analysis after automated immunofluorescence staining for epithelial markers. All experiments employed a density-based cell separation apparatus (AccuCyte) to separate nucleated cells from the blood and transfer them to microscopic slides. After staining, the slides were imaged using a digital scanning microscope (CyteFinder). Precisely counted model CTCs (mCTCs) from four cancer cell lines were spiked into whole blood to determine recovery rates. Individual mCTCs were removed from slides using a single-cell retrieval device (CytePicker™) for whole genome amplification and subsequent analysis by PCR and Sanger sequencing, whole exome sequencing, or array-based comparative genomic hybridization. Clinical CTCs were evaluated in blood samples from patients with different cancers in comparison with the CellSearch® system. AccuCyte--CyteFinder presented high-resolution images that allowed identification of mCTCs by morphologic and phenotypic features. Spike-in mCTC recoveries were between 90 and 91%. More than 80% of single-digit spike-in mCTCs were identified and even a single cell in 7.5 mL could be found. Analysis of single SKBR3 mCTCs identified presence of a known TP53 mutation by both PCR and whole exome sequencing, and confirmed the reported karyotype of this cell line. Patient sample CTC counts matched or exceeded CellSearch CTC counts in a small feasibility cohort. The AccuCyte--CyteFinder system is a comprehensive and sensitive platform for identification and characterization of CTCs that has been applied to the assessment of CTCs in cancer patient samples as well as the isolation of single cells for genomic analysis. It thus enables accurate non-invasive monitoring of CTCs and evolving cancer biology for personalized, molecularly-guided cancer treatment.
Predictive factors for long-term engraftment of autologous blood stem cells.
Duggan, P R; Guo, D; Luider, J; Auer, I; Klassen, J; Chaudhry, A; Morris, D; Glück, S; Brown, C B; Russell, J A; Stewart, D A
2000-12-01
Data from 170 consecutive patients aged 19-66 years (median age 46 years) who underwent unmanipulated autologous blood stem cell transplant (ASCT) were analyzed to determine if total CD34+ cells/kg infused, CD34+ subsets (CD34+41+, CD34+90+, CD34+33-, CD34+38-, CD34+38-DR-), peripheral blood CD34+ cell (PBCD34+) count on first apheresis day, or various clinical factors were associated with low blood counts 6 months post ASCT. Thirty-four patients were excluded from analysis either because of death (n = 17) or re-induction chemotherapy prior to 6 months post ASCT (n = 13), or because of lack of follow-up data (n = 4). Of the remaining 136 patients, 46% had low WBC ( < 4 x 10(9)/l), 41% low platelets (<150 x 10(9)/l), and 34% low hemoglobin ( < 120 g/l) at a median of 6 months following ASCT. By Spearman's rank correlation, both the total CD34+ cell dose/kg and the PBCD34+ count correlated with 6 month blood counts better than any subset of CD34+ cells or any clinical factor. The PBCD34+ count was overall a stronger predictor of 6 month blood counts than was the total CD34+ cells/kg infused. Both factors retained their significance in multivariate analysis, controlling for clinical factors. In conclusion, subsets of CD34+ cells and clinical factors are inferior to the total CD34+ cell dose/kg and PBCD34+ count in predicting 6 month blood counts following ASCT.
Shared performance monitor in a multiprocessor system
Chiu, George; Gara, Alan G.; Salapura, Valentina
2012-07-24
A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.
Braunstein, Sarah L; Robertson, McKaylee M; Myers, Julie; Abraham, Bisrat; Nash, Denis
2016-12-01
Trends in CD4 + T-cell count at human immunodeficiency virus (HIV) infection diagnosis and antiretroviral therapy (ART) initiation can be characterized using laboratory tests from surveillance. We used CD4 + T-cell counts and viral loads from New York City for persons who received a diagnosis of HIV infection during 2006-2012. From 2006 to 2012, the median CD4 + T-cell count increased from 325 to 379 cells/µL at diagnosis and from 178 to 360 cells/μL at ART initiation. CD4 + T-cell counts were consistently lower in women, blacks, Hispanics, persons who inject drugs, and heterosexuals. Increases in CD4 + T-cell count at diagnosis and ART initiation suggest that the time from HIV infection to ART initiation has been reduced substantially in New York City. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Spectroscopic micro-tomography of metallic-organic composites by means of photon-counting detectors
NASA Astrophysics Data System (ADS)
Pichotka, M.; Jakubek, J.; Vavrik, D.
2015-12-01
The presumed capabilities of photon counting detectors have aroused major expectations in several fields of research. In the field of nuclear imaging ample benefits over standard detectors are to be expected from photon counting devices. First of all a very high contrast, as has by now been verified in numerous experiments. The spectroscopic capabilities of photon counting detectors further allow material decomposition in computed tomography and therefore inherently adequate beam hardening correction. For these reasons measurement setups featuring standard X-ray tubes combined with photon counting detectors constitute a possible replacement of the much more cost intensive tomographic setups at synchrotron light-sources. The actual application of photon counting detectors in radiographic setups in recent years has been impeded by a number of practical issues, above all by restrictions in the detectors size. Currently two tomographic setups in Czech Republic feature photon counting large-area detectors (LAD) fabricated in Prague. The employed large area hybrid pixel-detector assemblies [1] consisting of 10×10/10×5 Timepix devices have a surface area of 143×143 mm2 / 143×71,5 mm2 respectively, suitable for micro-tomographic applications. In the near future LAD devices featuring the Medipix3 readout chip as well as heavy sensors (CdTe, GaAs) will become available. Data analysis is obtained by a number of in house software tools including iterative multi-energy volume reconstruction.In this paper tomographic analysis of of metallic-organic composites is employed to illustrate the capabilities of our technology. Other than successful material decomposition by spectroscopic tomography we present a method to suppress metal artefacts under certain conditions.
Morello, Fulvio; Cavalot, Giulia; Giachino, Francesca; Tizzani, Maria; Nazerian, Peiman; Carbone, Federica; Pivetta, Emanuele; Mengozzi, Giulio; Moiraghi, Corrado; Lupia, Enrico
2017-08-01
Pre-test probability assessment is key in the approach to suspected acute aortic syndromes (AASs). However, most patients with AAS-compatible symptoms are classified at low probability, warranting further evaluation for decision on aortic imaging. White blood cell count, platelet count and fibrinogen explore pathophysiological pathways mobilized in AASs and are routinely assayed in the workup of AASs. However, the diagnostic performance of these variables for AASs, alone and as a bundle, is unknown. We tested the hypothesis that white blood cell count, platelet count and/or fibrinogen at presentation may be applied as additional tools to standard clinical evaluation for pre-test risk assessment in patients at low probability of AAS. This was a retrospective observational study conducted on consecutive patients managed in our Emergency Department from 2009 to 2014 for suspected AAS. White blood cell count, platelet count and fibrinogen were assayed during evaluation in the Emergency Department. The final diagnosis was obtained by computed tomography angiography. The pre-test probability of AAS was defined according to guidelines. Of 1210 patients with suspected AAS, 1006 (83.1%) were classified at low probability, and 271 (22.4%) were diagnosed with AAS. Within patients at low probability, presence of at least one alteration among white blood cell count >9*10 3 /µl, platelet count <200*10 3 /µl and fibrinogen <350 mg/dl was associated with a sensitivity of 95.5% (89.7-98.5%) and a specificity of 18.3% (15.6-21.2%). In patients at low probability, white blood cell count >9*10 3 /µl and platelet count <200*10 3 /µl were found as independent predictors of AAS beyond established clinical risk markers. Within patients at low probability, the estimated risk of AAS based on the number of alterations amongst white blood cell count >9*10 3 /µl and platelet count <200*10 3 /µl was 2.7% (1.2-5.7%) with zero alterations, 11.3% (8.8-14.3%) with one alteration and 31.9% (24.8-40%) with two alterations ( p<0.001). In addition to standard clinical evaluation, white blood cell count and platelet count may be used in patients at low pre-test probability to fine-tune risk assessment of AAS.
Mehta, J S; Futter, C E; Sandeman, S R; Faragher, R G A F; Hing, K A; Tanner, K E; Allan, B D S
2005-10-01
Published clinical series suggest the osteoodontokeratoprosthesis (OOKP) may have a lower extrusion rate than current synthetic keratoprostheses. The OOKP is anchored in the eye wall by autologous tooth. The authors' aim was to compare adhesion, proliferation, and morphology for telomerase transformed keratocytes seeded on calcium hydroxyapatite (the principal mineral constituent of tooth) and materials used in the anchoring elements of commercially available synthetic keratoprostheses. Test materials were hydroxyapatite, polytetrafluoroethylene (PTFE), polyhydroxyethyl methacrylate (HEMA), and glass (control). Cell adhesion and viability were quantified at 4 hours, 24 hours, and 1 week using a calcein-AM/EthD-1 viability/cytotoxicity assay. Focal contact expression and cytoskeletal organisation were studied at 24 hours by confocal microscopy with immunoflourescent labelling. Further studies of cell morphology were performed using light and scanning electron microscopy. Live cell counts were significantly greater on hydroxyapatite surfaces at each time point (p<0.04). Dead cell counts were significantly higher for PTFE at 7 days (p<0.002). ss(1) integrin expression was highest on hydroxyapatite. Adhesion structures were well expressed in flat, spread out keratocytes on both HA and glass. Keratocytes tended to be thinner and spindle shaped on PTFE. The relatively few keratocytes visible on HEMA test surfaces were rounded and poorly adherent. Keratocyte adhesion, spreading, and viability on hydroxyapatite test surfaces is superior to that seen on PTFE and HEMA. Improving the initial cell adhesion environment in the skirt element of keratoprostheses may enhance tissue integration and reduce device failure rates.
A new approach for the estimation of phytoplankton cell counts associated with algal blooms.
Nazeer, Majid; Wong, Man Sing; Nichol, Janet Elizabeth
2017-07-15
This study proposes a method for estimating phytoplankton cell counts associated with an algal bloom, using satellite images coincident with in situ and meteorological parameters. Satellite images from Landsat Thematic Mapper (TM), Enhanced Thematic Mapper Plus (ETM+), Operational Land Imager (OLI) and HJ-1 A/B Charge Couple Device (CCD) sensors were integrated with the meteorological observations to provide an estimate of phytoplankton cell counts. All images were atmospherically corrected using the Second Simulation of the Satellite Signal in the Solar Spectrum (6S) atmospheric correction method with a possible error of 1.2%, 2.6%, 1.4% and 2.3% for blue (450-520nm), green (520-600nm), red (630-690nm) and near infrared (NIR 760-900nm) wavelengths, respectively. Results showed that the developed Artificial Neural Network (ANN) model yields a correlation coefficient (R) of 0.95 with the in situ validation data with Sum of Squared Error (SSE) of 0.34cell/ml, Mean Relative Error (MRE) of 0.154cells/ml and a bias of -504.87. The integration of the meteorological parameters with remote sensing observations provided a promising estimation of the algal scum as compared to previous studies. The applicability of the ANN model was tested over Hong Kong as well as over Lake Kasumigaura, Japan and Lake Okeechobee, Florida USA, where algal blooms were also reported. Further, a 40-year (1975-2014) red tide occurrence map was developed and revealed that the eastern and southern waters of Hong Kong are more vulnerable to red tides. Over the 40 years, 66% of red tide incidents were associated with the Dinoflagellates group, while the remainder were associated with the Diatom group (14%) and several other minor groups (20%). The developed technology can be applied to other similar environments in an efficient and cost-saving manner. Copyright © 2017 Elsevier B.V. All rights reserved.
Platelet Transfusion Practices in Critically Ill Children.
Nellis, Marianne E; Karam, Oliver; Mauer, Elizabeth; Cushing, Melissa M; Davis, Peter J; Steiner, Marie E; Tucci, Marisa; Stanworth, Simon J; Spinella, Philip C
2018-05-04
Little is known about platelet transfusions in pediatric critical illness. We sought to describe the epidemiology, indications, and outcomes of platelet transfusions among critically ill children. Prospective cohort study. Multicenter (82 PICUs), international (16 countries) from September 2016 to April 2017. Children ages 3 days to 16 years prescribed a platelet transfusion in the ICU during screening days. None. Over 6 weeks, 16,934 patients were eligible, and 559 received at least one platelet transfusion (prevalence, 3.3%). The indications for transfusion included prophylaxis (67%), minor bleeding (21%), and major bleeding (12%). Thirty-four percent of prophylactic platelet transfusions were prescribed when the platelet count was greater than or equal to 50 × 10 cells/L. The median (interquartile range) change in platelet count post transfusion was 48 × 10 cells/L (17-82 × 10 cells/L) for major bleeding, 42 × 10 cells/L (16-80 × 10 cells/L) for prophylactic transfusions to meet a defined threshold, 38 × 10 cells/L (17-72 × 10 cells/L) for minor bleeding, and 25 × 10 cells/L (10-47 × 10 cells/L) for prophylaxis in patients at risk of bleeding from a device. Overall ICU mortality was 25% but varied from 18% to 35% based on indication for transfusion. Upon adjusted analysis, total administered platelet dose was independently associated with increased ICU mortality (odds ratio for each additional 1 mL/kg platelets transfused, 1.002; 95% CI, 1.001-1.003; p = 0.005). The majority of platelet transfusions are given as prophylaxis to nonbleeding children, and significant variation in platelet thresholds exists. Studies are needed to clarify appropriate indications, with focus on prophylactic transfusions.
NASA Astrophysics Data System (ADS)
Powless, Amy J.; Feekin, Lauren E.; Hutcheson, Joshua A.; Alapat, Daisy V.; Muldoon, Timothy J.
2016-03-01
Point-of-care approaches for 3-part leukocyte differentials (granulocyte, monocyte, and lymphocyte), traditionally performed using a hematology analyzer within a panel of tests called a complete blood count (CBC), are essential not only to reduce cost but to provide faster results in low resource areas. Recent developments in lab-on-a-chip devices have shown promise in reducing the size and reagents used, relating to a decrease in overall cost. Furthermore, smartphone diagnostic approaches have shown much promise in the area of point-of-care diagnostics, but the relatively high per-unit cost may limit their utility in some settings. We present here a method to reduce computing cost of a simple epi-fluorescence imaging system using a Raspberry Pi (single-board computer, <$40) to perform a 3-part leukocyte differential comparable to results from a hematology analyzer. This system uses a USB color camera in conjunction with a leukocyte-selective vital dye (acridine orange) in order to determine a leukocyte count and differential from a low volume (<20 microliters) of whole blood obtained via fingerstick. Additionally, the system utilizes a "cloud-based" approach to send image data from the Raspberry Pi to a main server and return results back to the user, exporting the bulk of the computational requirements. Six images were acquired per minute with up to 200 cells per field of view. Preliminary results showed that the differential count varied significantly in monocytes with a 1 minute time difference indicating the importance of time-gating to produce an accurate/consist differential.
Large-scale femtoliter droplet array for digital counting of single biomolecules.
Kim, Soo Hyeon; Iwai, Shino; Araki, Suguru; Sakakihara, Shouichi; Iino, Ryota; Noji, Hiroyuki
2012-12-07
We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a conventional micropipette, this is achieved by sequential injection first with an aqueous solution containing beads, and then with fluorinated oil. The concentration of target biomolecules is estimated from the ratio of the number of signal-emitting droplets to the total number of trapped beads (digital counting). The performance of our digital counting device was demonstrated by detecting a streptavidin-β-galactosidase conjugate with a limit of detection (LOD) of 10 zM. The sensitivity of our device was >20-fold higher than that noted in previous studies where a smaller number of reactors (fifty thousand reactors) were used. Such a low LOD was achieved because of the large number of droplets in an array, allowing simultaneous examination of a large number of beads. When combined with bead-based enzyme-linked immunosorbent assay (digital ELISA), the LOD for the detection of prostate specific antigen reached 2 aM. This value, again, was improved over that noted in a previous study, because of the decreased coefficient of variance of the background measurement determined by the Poisson noise. Our digital counting device using one million droplets has great potential as a highly sensitive, portable immunoassay device that could be used to diagnose diseases.
Lindqvist, Daniel; Mellon, Synthia H; Dhabhar, Firdaus S; Yehuda, Rachel; Grenon, S Marlene; Flory, Janine D; Bierer, Linda M; Abu-Amara, Duna; Coy, Michelle; Makotkine, Iouri; Reus, Victor I; Aschbacher, Kirstin; Bersani, F Saverio; Marmar, Charles R; Wolkowitz, Owen M
2017-12-01
Inflammation is reported in post-traumatic stress disorder (PTSD). Few studies have investigated circulating blood cells that may contribute to inflammation. We assessed circulating platelets, white blood cells (WBC) and red blood cells (RBC) in PTSD and assessed their relationship to inflammation and symptom severity. One-hundred and sixty-three male combat-exposed veterans (82 PTSD, 81 non-PTSD) had blood assessed for platelets, WBC, and RBC. Data were correlated with symptom severity and inflammation. All cell counts were significantly elevated in PTSD. There were small mediation effects of BMI and smoking on these relationships. After adjusting for these, the differences in WBC and RBC remained significant, while platelet count was at trend level. In all subjects, all of the cell counts correlated significantly with inflammation. Platelet count correlated with inflammation only in the PTSD subjects. Platelet count, but none of the other cell counts, was directly correlated with PTSD severity ratings in the PTSD group. Combat PTSD is associated with elevations in RBC, WBC, and platelets. Dysregulation of all three major lineages of hematopoietic cells in PTSD, as well as their significant correlation with inflammation, suggest clinical significance of these changes. Copyright © 2017 Elsevier B.V. All rights reserved.
Mobile Device Accuracy for Step Counting Across Age Groups.
Modave, François; Guo, Yi; Bian, Jiang; Gurka, Matthew J; Parish, Alice; Smith, Megan D; Lee, Alexandra M; Buford, Thomas W
2017-06-28
Only one in five American meets the physical activity recommendations of the Department of Health and Human Services. The proliferation of wearable devices and smartphones for physical activity tracking has led to an increasing number of interventions designed to facilitate regular physical activity, in particular to address the obesity epidemic, but also for cardiovascular disease patients, cancer survivors, and older adults. However, the inconsistent findings pertaining to the accuracy of wearable devices for step counting needs to be addressed, as well as factors known to affect gait (and thus potentially impact accuracy) such as age, body mass index (BMI), or leading arm. We aim to assess the accuracy of recent mobile devices for counting steps, across three different age groups. We recruited 60 participants in three age groups: 18-39 years, 40-64 years, and 65-84 years, who completed two separate 1000 step walks on a treadmill at a self-selected speed between 2 and 3 miles per hour. We tested two smartphones attached on each side of the waist, and five wrist-based devices worn on both wrists (2 devices on one wrist and 3 devices on the other), as well as the Actigraph wGT3X-BT, and swapped sides between each walk. All devices were swapped dominant-to-nondominant side and vice-versa between the two 1000 step walks. The number of steps was recorded with a tally counter. Age, sex, height, weight, and dominant hand were self-reported by each participant. Among the 60 participants, 36 were female (60%) and 54 were right-handed (90%). Median age was 53 years (min=19, max=83), median BMI was 24.1 (min=18.4, max=39.6). There was no significant difference in left- and right-hand step counts by device. Our analyses show that the Fitbit Surge significantly undercounted steps across all age groups. Samsung Gear S2 significantly undercounted steps only for participants among the 40-64 year age group. Finally, the Nexus 6P significantly undercounted steps for the group ranging from 65-84 years. Our analysis shows that apart from the Fitbit Surge, most of the recent mobile devices we tested do not overcount or undercount steps in the 18-39-year-old age group, however some devices undercount steps in older age groups. This finding suggests that accuracy in step counting may be an issue with some popular wearable devices, and that age may be a factor in undercounting. These results are particularly important for clinical interventions using such devices and other activity trackers, in particular to balance energy requirements with energy expenditure in the context of a weight loss intervention program. ©François Modave, Yi Guo, Jiang Bian, Matthew J Gurka, Alice Parish, Megan D Smith, Alexandra M Lee, Thomas W Buford. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 28.06.2017.
Engsig, Frederik N; Zangerle, Robert; Katsarou, Olga; Dabis, Francois; Reiss, Peter; Gill, John; Porter, Kholoud; Sabin, Caroline; Riordan, Andrew; Fätkenheuer, Gerd; Gutiérrez, Félix; Raffi, Francois; Kirk, Ole; Mary-Krause, Murielle; Stephan, Christoph; de Olalla, Patricia Garcia; Guest, Jodie; Samji, Hasina; Castagna, Antonella; d'Arminio Monforte, Antonella; Skaletz-Rorowski, Adriane; Ramos, Jose; Lapadula, Giuseppe; Mussini, Cristina; Force, Lluís; Meyer, Laurence; Lampe, Fiona; Boufassa, Faroudy; Bucher, Heiner C; De Wit, Stéphane; Burkholder, Greer A; Teira, Ramon; Justice, Amy C; Sterling, Tim R; M Crane, Heidi; Gerstoft, Jan; Grarup, Jesper; May, Margaret; Chêne, Geneviève; Ingle, Suzanne M; Sterne, Jonathan; Obel, Niels
2014-05-01
Some human immunodeficiency virus (HIV)-infected individuals initiating combination antiretroviral therapy (cART) with low CD4 counts achieve viral suppression but not CD4 cell recovery. We aimed to identify (1) risk factors for failure to achieve CD4 count >200 cells/µL after 3 years of sustained viral suppression and (2) the association of the achieved CD4 count with subsequent mortality. We included treated HIV-infected adults from 2 large international HIV cohorts, who had viral suppression (≤500 HIV type 1 RNA copies/mL) for >3 years with CD4 count ≤200 cells/µL at start of the suppressed period. Logistic regression was used to identify risk factors for incomplete CD4 recovery (≤200 cells/µL) and Cox regression to identify associations with mortality. Of 5550 eligible individuals, 835 (15%) did not reach a CD4 count >200 cells/µL after 3 years of suppression. Increasing age, lower initial CD4 count, male heterosexual and injection drug use transmission, cART initiation after 1998, and longer time from initiation of cART to start of the virally suppressed period were risk factors for not achieving a CD4 count >200 cells/µL. Individuals with CD4 ≤200 cells/µL after 3 years of viral suppression had substantially increased mortality (adjusted hazard ratio, 2.60; 95% confidence interval, 1.86-3.61) compared with those who achieved CD4 count >200 cells/µL. The increased mortality was seen across different patient groups and for all causes of death. Virally suppressed HIV-positive individuals on cART who do not achieve a CD4 count >200 cells/µL have substantially increased long-term mortality.
Dusick, Allison; Young, Karen M; Muir, Peter
2014-12-01
Canine osteoarthritis is a common disorder seen in veterinary clinical practice and causes considerable morbidity in dogs as they age. Synovial fluid analysis is an important tool for diagnosis and treatment of canine joint disease and obtaining a total nucleated cell count (TNCC) is particularly important. However, the low sample volumes obtained during arthrocentesis are often insufficient for performing an automated TNCC, thereby limiting diagnostic interpretation. The aim of the present study was to investigate whether estimation of TNCC in canine synovial fluid could be achieved by performing manual cell counts on direct smears of fluid. Fifty-eight synovial fluid samples, taken by arthrocentesis from 48 dogs, were included in the study. Direct smears of synovial fluid were prepared, and hyaluronidase added before cell counts were obtained using a commercial laser-based instrument. A protocol was established to count nucleated cells in a specific region of the smear, using a serpentine counting pattern; the mean number of nucleated cells per 400 × field was then calculated. There was a positive correlation between the automated TNCC and mean manual cell count, with more variability at higher TNCC. Regression analysis was performed to estimate TNCC from manual counts. By this method, 78% of the samples were correctly predicted to fall into one of three categories (within the reference interval, mildly to moderately increased, or markedly increased) relative to the automated TNCC. Intra-observer and inter-observer agreement was good to excellent. The results of the study suggest that interpretation of canine synovial fluid samples of low volume can be aided by methodical manual counting of cells on direct smears. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cooper, R. J.; Amman, M.; Vetter, K.
2018-04-01
High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.
A novel method of personnel cooling in an operating theatre environment.
Casha, Aaron R; Manché, Alexander; Camilleri, Liberato; Gauci, Marilyn; Grima, Joseph N; Borg, Michael A
2014-10-01
An optimized theatre environment, including personal temperature regulation, can help maintain concentration, extend work times and may improve surgical outcomes. However, devices, such as cooling vests, are bulky and may impair the surgeon's mobility. We describe the use of a low-cost, low-energy 'bladeless fan' as a personal cooling device. The safety profile of this device was investigated by testing air quality using 0.5- and 5-µm particle counts as well as airborne bacterial counts on an operating table simulating a wound in a thoracic operation in a busy theatre environment. Particle and bacterial counts were obtained with both an empty and full theatre, with and without the 'bladeless fan'. The use of the 'bladeless fan' within the operating theatre during the simulated operation led to a minor, not statistically significant, lowering of both the particle and bacterial counts. In conclusion, the 'bladeless fan' is a safe, effective, low-cost and low-energy consumption solution for personnel cooling in a theatre environment that maintains the clean room conditions of the operating theatre. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Yuksel, Ozgur Haki; Verit, Ayhan; Sahin, Aytac; Urkmez, Ahmet; Uruc, Fatih
2016-01-01
The aim of the study was to investigate white blood cell counts and neutrophil to lymphocyte ratio (NLR) as markers of systemic inflammation in the diagnosis of localized testicular cancer as a malignancy with initially low volume. Thirty-six patients with localized testicular cancer with a mean age of 34.22±14.89 years and 36 healthy controls with a mean age of 26.67±2.89 years were enrolled in the study. White blood cell counts and NLR were calculated from complete blood cell counts. White blood cell counts and NLR were statistically significantly higher in patients with testicular cancer compared with the control group (p<0.0001 for all). Both white blood cell counts and NLR can be used as a simple test in the diagnosis of testicular cancer besides the well-known accurate serum tumor markers as AFP (alpha fetoprotein), hCG (human chorionic gonadotropin) and LDH (lactate dehydrogenase).
Modeling OPC complexity for design for manufacturability
NASA Astrophysics Data System (ADS)
Gupta, Puneet; Kahng, Andrew B.; Muddu, Swamy; Nakagawa, Sam; Park, Chul-Hong
2005-11-01
Increasing design complexity in sub-90nm designs results in increased mask complexity and cost. Resolution enhancement techniques (RET) such as assist feature addition, phase shifting (attenuated PSM) and aggressive optical proximity correction (OPC) help in preserving feature fidelity in silicon but increase mask complexity and cost. Data volume increase with rise in mask complexity is becoming prohibitive for manufacturing. Mask cost is determined by mask write time and mask inspection time, which are directly related to the complexity of features printed on the mask. Aggressive RET increase complexity by adding assist features and by modifying existing features. Passing design intent to OPC has been identified as a solution for reducing mask complexity and cost in several recent works. The goal of design-aware OPC is to relax OPC tolerances of layout features to minimize mask cost, without sacrificing parametric yield. To convey optimal OPC tolerances for manufacturing, design optimization should drive OPC tolerance optimization using models of mask cost for devices and wires. Design optimization should be aware of impact of OPC correction levels on mask cost and performance of the design. This work introduces mask cost characterization (MCC) that quantifies OPC complexity, measured in terms of fracture count of the mask, for different OPC tolerances. MCC with different OPC tolerances is a critical step in linking design and manufacturing. In this paper, we present a MCC methodology that provides models of fracture count of standard cells and wire patterns for use in design optimization. MCC cannot be performed by designers as they do not have access to foundry OPC recipes and RET tools. To build a fracture count model, we perform OPC and fracturing on a limited set of standard cells and wire configurations with all tolerance combinations. Separately, we identify the characteristics of the layout that impact fracture count. Based on the fracture count (FC) data from OPC and mask data preparation runs, we build models of FC as function of OPC tolerances and layout parameters.
Hanke, Alexander; Prantl, Lukas; Wenzel, Carina; Nerlich, Michael; Brockhoff, Gero; Loibl, Markus; Gehmert, Sebastian
2016-01-01
The stem cell rich Stromal Vascular Fraction (SVF) can be harvested by processing lipo-aspirate or fat tissue with an enzymatic digestion followed by centrifugation. To date neither a standardised extraction method for SVF nor a generally admitted protocol for cell application in patients exists. A novel commercially available semi-automated device for the extraction of SVF promises sterility, consistent results and usability in the clinical routine. The aim of this work was to compare the quantity and quality of the SVF between the new system and an established manual laboratory method. SVF was extracted from lipo-aspirate both by a prototype of the semi-automated UNiStation™ (NeoGenesis, Seoul, Korea) and by hand preparation with common laboratory equipment. Cell composition of the SVF was characterized by multi-parametric flow-cytometry (FACSCanto-II, BD Biosciences). The total cell number (quantity) of the SVF was determined as well the percentage of cells expressing the stem cell marker CD34, the leucocyte marker CD45 and the marker CD271 for highly proliferative stem cells (quality). Lipo-aspirate obtained from six patients was processed with both the novel device (d) and the hand preparation (h) which always resulted in a macroscopically visible SVF. However, there was a tendency of a fewer cell yield per gram of used lipo-aspirate with the device (d: 1.1×105±1.1×105 vs. h: 2.0×105±1.7×105; p = 0.06). Noteworthy, the percentage of CD34+ cells was significantly lower when using the device (d: 57.3% ±23.8% vs. h: 74.1% ±13.4%; p = 0.02) and CD45+ leukocyte counts tend to be higher when compared to the hand preparation (d: 20.7% ±15.8% vs. h: 9.8% ±7.1%; p = 0.07). The percentage of highly proliferative CD271+ cells was similar for both methods (d:12.9% ±9.6% vs. h: 13.4% ±11.6%; p = 0.74) and no differences were found for double positive cells of CD34+/CD45+ (d: 5.9% ±1.7% vs. h: 1.7% ±1.1%; p = 0.13), CD34+/CD271+ (d: 24.1% ±12.0% vs. h: 14.2% ±8.5%; p = 0.07). The semi-automated closed system provides a considerable amount of sterile SVF with high reproducibility. Furthermore, the SVF extracted by both methods showed a similar cell composition which is in accordance with the data from literature. This semi-automated device offers an opportunity to take research and application of the SVF one step further to the clinic.
Ford, Nathan; Shubber, Zara; Jarvis, Joseph N; Chiller, Tom; Greene, Greg; Migone, Chantal; Vitoria, Marco; Doherty, Meg; Meintjes, Graeme
2018-01-01
Abstract Background Current guidelines recommend screening all people living with human immunodeficiency virus (PLHIV) who have a CD4 count ≤100 cells/µL for cryptococcal antigen (CrAg) to identify those patients who could benefit from preemptive fluconazole treatment prior to the onset of meningitis. We conducted a systematic review to assess the prevalence of CrAg positivity at different CD4 cell counts. Methods We searched 4 databases and abstracts from 3 conferences up to 1 September 2017 for studies reporting prevalence of CrAg positivity according to CD4 cell count strata. Prevalence estimates were pooled using random effects models. Results Sixty studies met our inclusion criteria. The pooled prevalence of cryptococcal antigenemia was 6.5% (95% confidence interval [CI], 5.7%–7.3%; 54 studies) among patients with CD4 count ≤100 cells/µL and 2.0% (95% CI, 1.2%–2.7%; 21 studies) among patients with CD4 count 101–200 cells/µL. Twenty-one studies provided sufficient information to compare CrAg prevalence per strata; overall, 18.6% (95% CI, 15.4%–22.2%) of the CrAg-positive cases identified at ≤200 cells/µL (n = 11823) were identified among individuals with a CD4 count 101–200 cells/µL. CrAg prevalence was higher among inpatients (9.8% [95% CI, 4.0%–15.5%]) compared with outpatients (6.3% [95% CI, 5.3%–7.4%]). Conclusions The findings of this review support current recommendations to screen all PLHIV who have a CD4 count ≤100 cells/µL for CrAg and suggest that screening may be considered at CD4 cell count ≤200 cells/µL. PMID:29514236
The Reusable Handheld Electrolyte and Lab Technology for Humans (rHEALTH) Sensor
NASA Technical Reports Server (NTRS)
Chan, Eugene
2015-01-01
The DNA Medicine Institute has produced a reusable microfluidic device that performs rapid, low-cost cell counts and measurements of electrolytes, proteins, and other biomarkers. The rHEALTH sensor is compact and portable, and it employs cutting-edge fluorescence detection optics, innovative microfluidics, and nanostrip reagents to perform a suite of hematology, chemistry, and biomarker assays from a single drop of blood. A handful of current portable POC devices provide generalized blood analysis, but they perform only a few tests at a time. These devices also rely on disposable components and depend on diverse detection technologies to complete routine tests-all ill-suited for space travelers on extended missions. In contrast, the rHEALTH sensor integrates sample introduction, processing, and detection with a compact, resource-conscious, and efficient design. Developed to monitor astronaut health on the International Space Station and during long-term space flight, this microscale lab analysis tool also has terrestrial applications that include POC diagnostics conducted at a patient's bedside, in a doctor's office, and in a hospital.
Combined blood cell counting and classification with fluorochrome stains and flow instrumentation.
Shapiro, H M; Schildkraut, E R; Curbelo, R; Laird, C W; Turner, B; Hirschfeld, T
1976-01-01
A multiparameter flow cytophotometer was used to count and classify fixed human blood cells fluorochromed with a mixture of ethidium bromide (EB), brilliant sulfaflavine and a blue fluorescent stilbene disulfonic acid derivative (LN). The system measures light scattered by the cells and absorption at 420 nm for all cells. In addition, nuclear EB fluorescence (540 leads to 610 nm) and cytoplasmic fluorescence from LN (366 leads to 470 nm), brilliant sulfaflavine (420 leads to 520 nm) and EB exicted by energy transfer from LN (366 leads to 610 nm) are measured for all nucleated cells. This information is sufficient to perform red and white blood cell counts and to classify leukocytes as lymphocytes, monocytes, basophils, eosinophils or neutrophils. Light scattering and/or nuclear and cytoplasmic fluorescence values may be further analyzed to obtain the ratio of immature to mature neutrophils. Counts produced by the system are in reasonable agreement with those obtained by electronic cells counting and examination of Wright's-stained blood smears; some discrepancies appear to be due to systematic errors in the manual counting method.
Small, Fast TES Microcalorimeters with Unprecedented X-ray Spectral Performance
NASA Technical Reports Server (NTRS)
Eckart, M. E.; Adams, J. S.; Bailey, C. N.; Bandler, S. R.; Chervenak, J. A.; Finkbeiner, F. M.; Kelley, R. L.; Kilbourne, C. A.; Porter, F. S.; Sadleir, J. E.;
2011-01-01
Driven initially by the desire for X-ray microcalorimeter arrays suitable for imaging the dynamic solar corona, we have developed a transition-edge-sensor (TES) microcalorimeter optimization that exhibits a unique combination of high spectral resolving power and a wide X-ray bandpass. These devices have achieved spectral performance of dE approximately 1.3 eV FWHM at 1.5 keV, 1.6 eV at 6 keV, and 2.0 eV at 8 keV, using small TESs (e.g., approximately 35 micron x 35 micron) that operate in a regime in which the superconducting transition is highly current dependent. In order to accommodate high X-ray count rates, the devices sit directly on a solid substrate instead of on membranes, and we use an embedded heatsinking layer to reduce pixel-to-pixel crosstalk. We will present results from devices with a range of TES and absorber sizes, and from device wafers with varied embedded heatsink materials. This contribution will focus on count-rate capabilities, including a discussion of the trade-off between count rate and energy resolution, and the heatsinking design. We will also present preliminary tests of array readout using a code-division multiplexed SQUID readout scheme, which may be necessary to enable large arrays of these fast devices.
1984-06-01
UNSOLINTERRUPT: ; Dismiss unsolicited Interrupt. POPR M<RI,RI,R2,R3,R4,R5> ; Restore RZ-R5 REI ; Return from interrupt. .SBTTL AVCANCEL. Cancel I/O routine...Dismiss unsolicited Interrupt. POPR M<R8,RI.R2,R3,R4,R5> ; Restore RN-R5 REI ; Return from interrupt. .SBTTL ODCANCEL, Cancel I/0 routine ++ I ODCANCEL...output buffer. ODREGDU4P: i Dump device registers MOVZBL ODNUMREGS,(Rg)+ i Store device register count. NOVZWL UCBSWODBYTCNT(RS),- aStore BYTE count
Hosokawa, Masahito; Asami, Marie; Yoshino, Tomoko; Tsujimura, Noriyuki; Takahashi, Masayuki; Nakasono, Satoshi; Tanaka, Tsuyoshi; Matsunaga, Tadashi
2013-02-15
Monitoring of hematotoxicity, which requires serial blood collection, is difficult to carry out in small animals due to a lack of non-invasive, individual animal-appropriate techniques that enable enumeration of leukocyte subsets from limited amounts of whole blood. In this study, a microfluidic device equipped with a microcavity array that enables highly efficient separation of leukocytes from submicroliters of whole blood was applied for hematotoxicity monitoring in mice. The microcavity array can specifically separate leukocytes from whole blood based on differences in the size and deformability between leukocytes and other blood cells. Mouse leukocytes recovered on aligned microcavities were continuously processed for image-based immunophenotypic analysis. Our device successfully recovered almost 100% of mouse leukocytes in 0.1 μL of whole blood without the effect of serial blood collection such as changes in body weight and total leukocyte count. We assessed benzene-associated hematotoxicity in mice using this system. Mice were administered with benzene once daily and the depression of leukocyte numbers induced in individual mice was successfully monitored from tail vein blood collected every other day for 2 weeks. Serial monitoring of the leukocyte number in individual mice will contribute to the understanding of hematotoxicity and reduction of the number of animal experiment trials. Copyright © 2012 Elsevier B.V. All rights reserved.
Bernstein, P S; Minior, V K; Divon, M Y
1997-11-01
The presence of elevated nucleated red blood cell counts in neonatal blood has been associated with fetal hypoxia. We sought to determine whether small-for-gestational-age fetuses with abnormal umbilical artery Doppler velocity waveforms have elevated nucleated red blood cell counts. Hospital charts of neonates with the discharge diagnosis of small for gestational age (birth weight < 10th percentile) who were delivered between October 1988 and June 1995 were reviewed for antepartum testing, delivery conditions, and neonatal outcome. We studied fetuses who had an umbilical artery systolic/diastolic ratio within 3 days of delivery and a complete blood cell count on the first day of life. Multiple gestations, anomalous fetuses, and infants of diabetic mothers were excluded. Statistical analysis included the Student t test, chi 2 analysis, analysis of variance, and simple and stepwise regression. Fifty-two infants met the inclusion criteria. Those with absent or reversed end-diastolic velocity (n = 19) had significantly greater nucleated red blood cell counts than did those with end-diastolic velocity present (n = 33) (nucleated red blood cells/100 nucleated cells +/- SD: 135.5 +/- 138 vs 17.4 +/- 23.7, p < 0.0001). These infants exhibited significantly longer time intervals for clearance of nucleated red blood cells from their circulation (p < 0.0001). They also had lower birth weights (p < 0.05), lower initial platelet count (p = 0.0006), lower arterial cord blood pH (p < 0.05), higher cord blood base deficit (p < 0.05), and an increased likelihood of cesarean section for "fetal distress" (p < 0.05). Multivariate analysis demonstrated that absent or reversed end-diastolic velocity (p < 0.0001) and low birth weight (p < 0.0001) contributed to the elevation of the nucleated red blood cell count, whereas gestational age at delivery was not a significant contributor. We observed significantly greater nucleated red blood cell counts and lower platelet counts in small-for-gestational-age fetuses with abnormal umbilical artery Doppler studies. This may suggest that antenatal thrombotic events lead to an increased placental impedance. Fetal response to this chronic condition may result in an increased nucleated red blood cell count.
High throughput single cell counting in droplet-based microfluidics.
Lu, Heng; Caen, Ouriel; Vrignon, Jeremy; Zonta, Eleonora; El Harrak, Zakaria; Nizard, Philippe; Baret, Jean-Christophe; Taly, Valérie
2017-05-02
Droplet-based microfluidics is extensively and increasingly used for high-throughput single-cell studies. However, the accuracy of the cell counting method directly impacts the robustness of such studies. We describe here a simple and precise method to accurately count a large number of adherent and non-adherent human cells as well as bacteria. Our microfluidic hemocytometer provides statistically relevant data on large populations of cells at a high-throughput, used to characterize cell encapsulation and cell viability during incubation in droplets.
Wright, S T; Petoumenos, K; Boyd, M; Carr, A; Downing, S; O'Connor, C C; Grotowski, M; Law, M G
2013-04-01
The aim of this study was to describe the long-term changes in CD4 cell counts beyond 5 years of combination antiretroviral therapy (cART). If natural ageing leads to a long-term decline in the immune system via low-grade chronic immune activation/inflammation, then one might expect to see a greater or earlier decline in CD4 counts in older HIV-positive patients with increasing duration of cART. Retrospective and prospective data were examined from long-term virologically stable HIV-positive adults from the Australian HIV Observational Database. We estimated mean CD4 cell count changes following the completion of 5 years of cART using linear mixed models. A total of 37 916 CD4 measurements were observed for 892 patients over a combined total of 9753 patient-years. Older patients (> 50 years old) at cART initiation had estimated mean (95% confidence interval) changes in CD4 counts by year-5 CD4 count strata (< 500, 500-750 and > 750 cells/μL) of 14 (7 to 21), 3 (-5 to 11) and -6 (-17 to 4) cells/μL/year. Of the CD4 cell count rates of change estimated, none were indicative of long-term declines in CD4 cell counts. Our results suggest that duration of cART and increasing age do not result in decreasing mean changes in CD4 cell counts for long-term virologically suppressed patients, indicating that the level of immune recovery achieved during the first 5 years of treatment is sustained through long-term cART. © 2012 British HIV Association.
WRIGHT, ST; PETOUMENOS, K; BOYD, M; CARR, A; DOWNING, S; O’CONNOR, CC; GROTOWSKI, M; LAW, MG
2012-01-01
Background The aim of this analysis is to describe the long-term changes in CD4 cell counts beyond 5 years of combination antiretroviral therapy (cART). If natural ageing leads to a long-term decline in the immune system via low-grade chronic immune activation/inflammation, then one might expect to see a greater or earlier decline in CD4 counts in older HIV-positive patients with increasing duration of cART. Methods Retrospective and prospective data were examined from long-term virologically stable HIV-positive adults from the Australian HIV Observational Database. We estimated mean CD4 cell counts changes following the completion of 5 years of cART using linear mixed models. Results A total of 37,916 CD4 measurements were observed for 892 patients over a combined total of 9,753 patient years. Older patients (>50 years) at cART initiation had estimated mean(95% confidence interval) change in CD4 counts by Year-5 CD4 count strata (<500, 501–750 and >750 cells/μL) of 14(7 to 21), 3(−5 to 11) and −6(−17 to 4) cells/μL/year. Of the CD4 cell count rates of change estimated, none were indicative of long-term declines in CD4 cell counts. Conclusions Our results suggest that duration of cART and increasing age does not result in decreasing mean changes in CD4 cell counts for long-term virologically suppressed patients. Indicating that level of immune recovery achieved during the first 5 years of treatment are sustained through long-term cART. PMID:23036045
A microfluidic biochip for complete blood cell counts at the point-of-care
Hassan, U.; Reddy, B.; Damhorst, G.; Sonoiki, O.; Ghonge, T.; Yang, C.; Bashir, R.
2016-01-01
Complete blood cell counts (CBCs) are one of the most commonly ordered and informative blood tests in hospitals. The results from a CBC, which typically include white blood cell (WBC) counts with differentials, red blood cell (RBC) counts, platelet counts and hemoglobin measurements, can have implications for the diagnosis and screening of hundreds of diseases and treatments. Bulky and expensive hematology analyzers are currently used as a gold standard for acquiring CBCs. For nearly all CBCs performed today, the patient must travel to either a hospital with a large laboratory or to a centralized lab testing facility. There is a tremendous need for an automated, portable point-of-care blood cell counter that could yield results in a matter of minutes from a drop of blood without any trained professionals to operate the instrument. We have developed microfluidic biochips capable of a partial CBC using only a drop of whole blood. Total leukocyte and their 3-part differential count are obtained from 10 μL of blood after on-chip lysing of the RBCs and counting of the leukocytes electrically using microfabricated platinum electrodes. For RBCs and platelets, 1 μL of whole blood is diluted with PBS on-chip and the cells are counted electrically. The total time for measurement is under 20 minutes. We demonstrate a high correlation of blood cell counts compared to results acquired with a commercial hematology analyzer. This technology could potentially have tremendous applications in hospitals at the bedside, private clinics, retail clinics and the developing world. PMID:26909365
A microfluidic biochip for complete blood cell counts at the point-of-care.
Hassan, U; Reddy, B; Damhorst, G; Sonoiki, O; Ghonge, T; Yang, C; Bashir, R
2015-12-01
Complete blood cell counts (CBCs) are one of the most commonly ordered and informative blood tests in hospitals. The results from a CBC, which typically include white blood cell (WBC) counts with differentials, red blood cell (RBC) counts, platelet counts and hemoglobin measurements, can have implications for the diagnosis and screening of hundreds of diseases and treatments. Bulky and expensive hematology analyzers are currently used as a gold standard for acquiring CBCs. For nearly all CBCs performed today, the patient must travel to either a hospital with a large laboratory or to a centralized lab testing facility. There is a tremendous need for an automated, portable point-of-care blood cell counter that could yield results in a matter of minutes from a drop of blood without any trained professionals to operate the instrument. We have developed microfluidic biochips capable of a partial CBC using only a drop of whole blood. Total leukocyte and their 3-part differential count are obtained from 10 μL of blood after on-chip lysing of the RBCs and counting of the leukocytes electrically using microfabricated platinum electrodes. For RBCs and platelets, 1 μL of whole blood is diluted with PBS on-chip and the cells are counted electrically. The total time for measurement is under 20 minutes. We demonstrate a high correlation of blood cell counts compared to results acquired with a commercial hematology analyzer. This technology could potentially have tremendous applications in hospitals at the bedside, private clinics, retail clinics and the developing world.
Immature germ cells in semen - correlation with total sperm count and sperm motility.
Patil, Priya S; Humbarwadi, Rajendra S; Patil, Ashalata D; Gune, Anita R
2013-07-01
Current data regarding infertility suggests that male factor contributes up to 30% of the total cases of infertility. Semen analysis reveals the presence of spermatozoa as well as a number of non-sperm cells, presently being mentioned in routine semen report as "round cells" without further differentiating them into leucocytes or immature germ cells. The aim of this work was to study a simple, cost-effective, and convenient method for differentiating the round cells in semen into immature germ cells and leucocytes and correlating them with total sperm counts and motility. Semen samples from 120 males, who had come for investigation for infertility, were collected, semen parameters recorded, and stained smears studied for different round cells. Statistical analysis of the data was done to correlate total sperm counts and sperm motility with the occurrence of immature germ cells and leucocytes. The average shedding of immature germ cells in different groups with normal and low sperm counts was compared. The clinical significance of "round cells" in semen and their differentiation into leucocytes and immature germ cells are discussed. Round cells in semen can be differentiated into immature germ cells and leucocytes using simple staining methods. The differential counts mentioned in a semen report give valuable and clinically relevant information. In this study, we observed a negative correlation between total count and immature germ cells, as well as sperm motility and shedding of immature germ cells. The latter was statistically significant with a P value 0.000.
Nonomura, N; Takayama, H; Nishimura, K; Oka, D; Nakai, Y; Shiba, M; Tsujimura, A; Nakayama, M; Aozasa, K; Okuyama, A
2007-01-01
Mast cell infiltration is often observed around human tumours. Inflammatory cells such as macrophages, neutrophils and mast cells infiltrating around tumours are known to contribute to tumour growth; however, the clinical significance of mast cell invasion in prostate cancer (PCa) has not been investigated. Mast cell infiltration was evaluated in 104 patients (age range, 45–88 years; median, 72 years), who underwent needle biopsy of the prostate and were confirmed to have PCa. Needle biopsy specimens of prostate were sliced into 5-μm-thick sections and immunostained for mast cells with monoclonal antibody against mast cell-specific tryptase. Mast cells were counted systematically under a microscope (× 400 magnification), and the relations between mast cell numbers and clinicopathologic findings were evaluated. The mast cell count was evaluated for prognostic value by multivariate analysis. Mast cells were immunostained around the cancer foci. The median number of mast cells in each case was 16. The mast cell count was higher around cancer foci in patients with higher Gleason scores than in those with low Gleason scores. The mast cell number correlated well with clinical stage (P<0.001). Prostate-specific antigen-free survival of patients with higher mast cell counts was better than that in patients with lower mast cell counts (P<0.001). Multivariate analysis revealed that mast cell count was a significant prognostic factor (P<0.005). The number of mast cells infiltrating around cancer foci in prostate biopsy specimens can be a significant prognostic factor of PCa. PMID:17848955
May, Margaret T.; Gompels, Mark; Delpech, Valerie; Porter, Kholoud; Orkin, Chloe; Kegg, Stephen; Hay, Phillip; Johnson, Margaret; Palfreeman, Adrian; Gilson, Richard; Chadwick, David; Martin, Fabiola; Hill, Teresa; Walsh, John; Post, Frank; Fisher, Martin; Ainsworth, Jonathan; Jose, Sophie; Leen, Clifford; Nelson, Mark; Anderson, Jane; Sabin, Caroline
2014-01-01
Objective: The objective of this study is to estimate life expectancies of HIV-positive patients conditional on response to antiretroviral therapy (ART). Methods: Patients aged more than 20 years who started ART during 2000–2010 (excluding IDU) in HIV clinics contributing to the UK CHIC Study were followed for mortality until 2012. We determined the latest CD4+ cell count and viral load before ART and in each of years 1–5 of ART. For each duration of ART, life tables based on estimated mortality rates by sex, age, latest CD4+ cell count and viral suppression (HIV-1 RNA <400 copies/ml), were used to estimate expected age at death for ages 20–85 years. Results: Of 21 388 patients who started ART, 961 (4.5%) died during 110 697 person-years. At start of ART, expected age at death [95% confidence interval (CI)] of 35-year-old men with CD4+ cell count less than 200, 200–349, at least 350 cells/μl was 71 (68–73), 78 (74–82) and 77 (72–81) years, respectively, compared with 78 years for men in the general UK population. Thirty-five-year-old men who increased their CD4+ cell count in the first year of ART from less than 200 to 200–349 or at least 350 cells/μl and achieved viral suppression gained 7 and 10 years, respectively. After 5 years on ART, expected age at death of 35-year-old men varied from 54 (48–61) (CD4+ cell count <200 cells/μl and no viral suppression) to 80 (76–83) years (CD4+ cell count ≥350 cells/μl and viral suppression). Conclusion: Successfully treated HIV-positive individuals have a normal life expectancy. Patients who started ART with a low CD4+ cell count significantly improve their life expectancy if they have a good CD4+ cell count response and undetectable viral load. PMID:24556869
Shao, Lingyun; Zhang, Xinyun; Gao, Yan; Xu, Yunya; Zhang, Shu; Yu, Shenglei; Weng, Xinhua; Shen, Hongbo; Chen, Zheng W; Jiang, Weimin; Zhang, Wenhong
2016-01-01
Detailed studies of correlation between HIV-M.tb co-infection and hierarchy declines of CD8+/CD4+ T-cell counts and IFN-γ responses have not been done. We conducted case-control studies to address this issue. 164 HIV-1-infected individuals comprised of HIV-1+ATB, HIV-1+LTB and HIV-1+TB- groups were evaluated. Immune phenotyping and complete blood count (CBC) were employed to measure CD4+ and CD8+ T-cell counts; T.SPOT.TB and intracellular cytokine staining (ICS) were utilized to detect ESAT6, CFP10 or PPD-specific IFN-γ responses. There were significant differences in median CD4+ T-cell counts between HIV-1+ATB (164/μL), HIV-1+LTB (447/μL) and HIV-1+TB- (329/μL) groups. Hierarchy low CD4+ T-cell counts (<200/μL, 200-500/μL, >500/μL) were correlated significantly with active TB but not M.tb co-infection. Interestingly, hierarchy low CD8+ T-cell counts were not only associated significantly with active TB but also with M.tb co-infection (P<0.001). Immunologically, HIV-1+ATB group showed significantly lower numbers of ESAT-6-/CFP-10-specific IFN-γ+ T cells than HIV-1+LTB group. Consistently, PPD-specific IFN-γ+CD4+/CD8+ T effector cells in HIV-1+ATB group were significantly lower than those in HIV-1+LTB group (P<0.001). Hierarchy low CD8+ T-cell counts and effector function in HIV-1-infected individuals are correlated with both M.tb co-infection and active TB. Hierarchy low CD4+ T-cell counts and Th1 effector function in HIV-1+ individuals are associated with increased frequencies of active TB, but not M.tb co-infection.
Application of a non-hazardous vital dye for cell counting with automated cell counters.
Kim, Soo In; Kim, Hyun Jeong; Lee, Ho-Jae; Lee, Kiwon; Hong, Dongpyo; Lim, Hyunchang; Cho, Keunchang; Jung, Neoncheol; Yi, Yong Weon
2016-01-01
Recent advances in automated cell counters enable us to count cells more easily with consistency. However, the wide use of the traditional vital dye trypan blue (TB) raises environmental and health concerns due to its potential teratogenic effects. To avoid this chemical hazard, it is of importance to introduce an alternative non-hazardous vital dye that is compatible with automated cell counters. Erythrosin B (EB) is a vital dye that is impermeable to biological membranes and is used as a food additive. Similarly to TB, EB stains only nonviable cells with disintegrated membranes. However, EB is less popular than TB and is seldom used with automated cell counters. We found that cell counting accuracy with EB was comparable to that with TB. EB was found to be an effective dye for accurate counting of cells with different viabilities across three different automated cell counters. In contrast to TB, EB was less toxic to cultured HL-60 cells during the cell counting process. These results indicate that replacing TB with EB for use with automated cell counters will significantly reduce the hazardous risk while producing comparable results. Copyright © 2015 Logos Biosystems, Inc. Published by Elsevier Inc. All rights reserved.
Hussain, Tahziba; Kulshreshtha, K K; Yadav, V S; Katoch, Kiran
2015-01-01
In this study, we estimated the CD4+, CD8+, CD3+ cell counts and the CD4/CD8 ratio among normal healthy controls (adults and children), leprosy patients (without any complications and during reactional states), TB patients (with and without HIV), and HIV-positive patients (early infection and full-blown AIDS) and correlated the changes with disease progression. In our study, it was observed that among adults, CD4+ cell counts ranged from 518-1098, CD8+ from 312-952, whereas CD4/CD8 ratio from 0.75-2.30. Among children, both CD4+ and CD8+ cells were more and the CD4/CD8 ratio varied from 0.91-3.17. With regard to leprosy patients, we observed that CD4+ and CD8+ cell counts were lower among PB (pauci-bacillary) and MB (multi-bacillary) patients. CD4/CD8 ratio was 0.99 ± 0.28 among PB patients while the ratio was lower, 0.78 ± 0.20, among MB patients. CD4+ cell counts were raised during RR (reversal reactions) and ENL (erythema nodosum leprosum) among the PB and MB patients whereas the CD8+ cell counts were lower among PB and MB patients. CD4/CD8 ratio doubled during reactional episodes of RR and ENL. Among the HIV-negative tuberculosis (TB) patients, both the CD4+ and CD8+ cell counts were found to be less and the CD4/CD8 ratio varied between 0.53-1.75. Among the HIV-positive TB patients and HIV-positive patients, both the CD4+ and CD8+ cells were very less and ratio drops significantly. In the initial stages of infection, as CD4+ counts drop, an increase in the CD8+ cell counts was observed and the ratio declines. In full-blown cases, CD4+ cell counts were very low, 3-4 to 54 cells, CD8+ cells from 12-211 and the ratio drops too low. This study is the first of its kind in this region of the country and assumes importance since no other study has reported the values of CD4+ and CD8+ T-lymphocyte counts among patients with mycobacterial diseases (leprosy and TB), HIV infections along with normal healthy individuals of the region, and correlation with clinical presentations of patients.
Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.
Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin
2015-12-01
Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.
Coetzee, Lindi Marie; Cassim, Naseem; Glencross, Deborah Kim
2017-05-24
South Africa (SA)'s Comprehensive HIV and AIDS Care, Management and Treatment (CCMT) programme has reduced new HIV infections and HIV-related deaths. In spite of progress made, 11.2% of South Africans (4.02 million) were living with HIV in 2015. The National Health Laboratory Service (NHLS) in SA performs CD4 testing in support of the CCMT programme and collates data through the NHLS Corporate Data Warehouse. The objective of this study was to assess the distribution of CD4 counts <100 cells/µL (defining severely immunosuppressed HIV-positive patients) and >500 cells/µL (as an HIV-positive 'wellness' indicator). CD4 data were extracted for the financial years 2010/11 and 2014/15, according to the district where the test was ordered, for predefined CD4 ranges. National and provincial averages of CD4 counts <100 and >500 cells/µL were calculated. Data were analysed using Stata 12 and mapping was done with ArcGIS software, reporting percentages of CD4 counts <100 and >500 cells/µL by district. The national average percentage of patients with CD4 counts <100 cells/µL showed a marked decrease (by 22%) over the 5-year study period, with a concurrent increase in CD4 counts >500 cells/µL (by 57%). District-by-district analysis showed that in 2010/11, 44/52 districts had >10% of CD4 samples with counts <100 cells/µL, decreasing to only 17/52 districts by 2014/15. Overall, districts in the Western Cape and KwaZulu-Natal had the lowest percentages of CD4 counts <100 cells/µL, as well as the highest percentages of counts >500 cells/µL. In contrast, in 2014/15, the highest percentages of CD4 counts <100 cells/µL were noted in the West Rand (Gauteng), Vhembe (Limpopo) and Nelson Mandela Bay (Eastern Cape) districts, where the lowest percentages of counts >500 cells/µL were also noted. The percentages of CD4 counts <100 cells/µL highlighted here reveal districts with positive change suggestive of programmatic improvements, and also highlight districts requiring local interventions to achieve the UNAIDS/SA National Department of Health 90-90-90 HIV treatment goals. The study further underscores the value of using NHLS laboratory data, an underutilised national resource, to leverage laboratory test data to enable a more comprehensive understanding of programme-specific health indicators.
Cerebellar pathology in childhood-onset vs. adult-onset essential tremor.
Louis, Elan D; Kuo, Sheng-Han; Tate, William J; Kelly, Geoffrey C; Faust, Phyllis L
2017-10-17
Although the incidence of ET increases with advancing age, the disease may begin at any age, including childhood. The question arises as to whether childhood-onset ET cases manifest the same sets of pathological changes in the cerebellum as those whose onset is during adult life. We quantified a broad range of postmortem features (Purkinje cell [PC] counts, PC axonal torpedoes, a host of associated axonal changes [PC axonal recurrent collateral count, PC thickened axonal profile count, PC axonal branching count], heterotopic PCs, and basket cell rating) in 60 ET cases (11 childhood-onset and 49 adult-onset) and 30 controls. Compared to controls, childhood-onset ET cases had lower PC counts, higher torpedo counts, higher heterotopic PC counts, higher basket cell plexus rating, and marginally higher PC axonal recurrent collateral counts. The median PC thickened axonal profile count and median PC axonal branching count were two to five times higher in childhood-onset ET than controls, but the differences did not reach statistical significance. Childhood-onset and adult-onset ET had similar PC counts, torpedo counts, heterotopic PC counts, basket cell plexus rating, PC axonal recurrent collateral counts, PC thickened axonal profile count and PC axonal branching count. In conclusion, we found that childhood-onset and adult-onset ET shared similar pathological changes in the cerebellum. The data suggest that pathological changes we have observed in the cerebellum in ET are a part of the pathophysiological cascade of events in both forms of the disease and that both groups seem to reach the same pathological endpoints at a similar age of death. Copyright © 2017 Elsevier B.V. All rights reserved.
Elevated endothelial progenitor cells during painful sickle cell crisis.
van Beem, Rachel T; Nur, Erfan; Zwaginga, Jaap Jan; Landburg, Precious P; van Beers, Eduard J; Duits, Ashley J; Brandjes, Dees P; Lommerse, Ingrid; de Boer, Hetty C; van der Schoot, C Ellen; Schnog, John-John B; Biemond, Bart J
2009-09-01
Circulating endothelial progenitor cells (EPCs) counts were determined in patients with sickle cell disease (SCD) to elucidate their role in SCD-related ischemia-induced angiogenesis and reendothelialization. Circulating EPC counts (KDR(+)/CD34(+)/Cd45(dim) cells) and their relation to serum levels of EPC mobilizing growth factors erythropoietin, vascular endothelial growth factor, and interleukin-8 were investigated in SCD patients during asymptomatic state (n=66) and painful crisis (n=36) and compared to healthy controls (n=13). EPC counts were comparable between controls (0; range, 0-1.1 cells/mL) and patients (0; range, 0-0 cells/mL) in asymptomatic state, but were significantly higher during painful crisis (41.7; range, 0-186 cells/mL; p<0.05). Also in a paired analysis of 12 patients who were included both during asymptomatic state and painful crisis, EPC counts increased significantly during painful crisis (from 0 [range, 0-0] to 26 [range, 0-149 cell/mL; p<0.05). EPC counts were not related to any of the measured growth factors. The higher EPC counts during painful crisis might indicate a role for EPC mobilization in reendothelialization. As a relationship of EPCs with the established mobilizing growth factors, measured in this study was not observed, the mechanism of EPC mobilization in SCD remains to be elucidated.
Different binarization processes validated against manual counts of fluorescent bacterial cells.
Tamminga, Gerrit G; Paulitsch-Fuchs, Astrid H; Jansen, Gijsbert J; Euverink, Gert-Jan W
2016-09-01
State of the art software methods (such as fixed value approaches or statistical approaches) to create a binary image of fluorescent bacterial cells are not as accurate and precise as they should be for counting bacteria and measuring their area. To overcome these bottlenecks, we introduce biological significance to obtain a binary image from a greyscale microscopic image. Using our biological significance approach we are able to automatically count about the same number of cells as an individual researcher would do by manual/visual counting. Using the fixed value or statistical approach to obtain a binary image leads to about 20% less cells in automatic counting. In our procedure we included the area measurements of the bacterial cells to determine the right parameters for background subtraction and threshold values. In an iterative process the threshold and background subtraction values were incremented until the number of particles smaller than a typical bacterial cell is less than the number of bacterial cells with a certain area. This research also shows that every image has a specific threshold with respect to the optical system, magnification and staining procedure as well as the exposure time. The biological significance approach shows that automatic counting can be performed with the same accuracy, precision and reproducibility as manual counting. The same approach can be used to count bacterial cells using different optical systems (Leica, Olympus and Navitar), magnification factors (200× and 400×), staining procedures (DNA (Propidium Iodide) and RNA (FISH)) and substrates (polycarbonate filter or glass). Copyright © 2016 Elsevier B.V. All rights reserved.
Mobile flow cytometer for mHealth.
Balsam, Joshua; Bruck, Hugh Alan; Rasooly, Avraham
2015-01-01
Flow cytometry is used for cell counting and analysis in numerous clinical and environmental applications. However flow cytometry is not used in mHealth mainly because current flow cytometers are large, expensive, power-intensive devices designed to operate in a laboratory. Their design results in a lack of portability and makes them unsuitable for mHealth applications. Another limitation of current technology is the low volumetric throughput rates that are not suitable for rapid detection of rare cells.To address these limitations, we describe here a novel, low-cost, mobile flow cytometer based on wide-field imaging with a webcam for large volume and high throughput fluorescence detection of rare cells as a simulation for circulating tumor cells (CTCs) detection. The mobile flow cytometer uses a commercially available webcam capable of 187 frames per second video capture at a resolution of 320 × 240 pixels. For fluorescence detection, a 1 W 450 nm blue laser is used for excitation of Syto-9 fluorescently stained cells detected at 535 nm. A wide-field flow cell was developed for large volume analysis that allows for the linear velocity of target cells to be lower than in conventional hydrodynamic focusing flow cells typically used in cytometry. The mobile flow cytometer was found to be capable of detecting low concentrations at flow rates of 500 μL/min, suitable for rare cell detection in large volumes. The simplicity and low cost of this device suggests that it may have a potential clinical use for mHealth flow cytometry for resource-poor settings associated with global health.
Accuracy of piezoelectric pedometer and accelerometer step counts.
Cruz, Joana; Brooks, Dina; Marques, Alda
2017-04-01
This study aimed to assess step-count accuracy of a piezoeletric pedometer (Yamax PW/EX-510), when worn at different body parts, and a triaxial accelerometer (GT3X+), and to compare device accuracy; and identify the preferred location(s) to wear a pedometer. Sixty-three healthy adults (45.8±20.6 years old) wore 7 pedometers (neck, lateral right and left of the waist, front right and left of the waist, front pockets of the trousers) and 1 accelerometer (over the right hip), while walking 120 m at slow, self-preferred/normal and fast paces. Steps were recorded. Participants identified their preferred location(s) to wear the pedometer. Absolute percent error (APE) and Bland and Altman (BA) method were used to assess device accuracy (criterion measure: manual counts) and BA method for device comparisons. Pedometer APE was below 3% at normal and fast paces despite wearing location, but higher at slow pace (4.5-9.1%). Pedometers were more accurate at the front waist and inside the pockets. Accelerometer APE was higher than pedometer APE (P<0.05); nevertheless, limits of agreement between devices were relatively small. Preferred wearing locations were inside the front right (N.=25) and left (N.=20) pockets of the trousers. Yamax PW/EX-510 pedometers may be preferable than GT3X+ accelerometers to count steps, as they provide more accurate results. These pedometers should be worn at the front right or left positions of the waist or inside the front pockets of the trousers.
Colyer, R.; Siegmund, O.; Tremsin, A.; Vallerga, J.; Weiss, S.; Michalet, X.
2011-01-01
Fluorescence lifetime imaging (FLIM) is a powerful approach to studying the immediate environment of molecules. For example, it is used in biology to study changes in the chemical environment, or to study binding processes, aggregation, and conformational changes by measuring Förster resonance energy transfer (FRET) between donor and acceptor fluorophores. FLIM can be acquired by time-domain measurements (time-correlated single-photon counting) or frequency-domain measurements (with PMT modulation or digital frequency domain acquisition) in a confocal setup, or with wide-field systems (using time-gated cameras). In the best cases, the resulting data is analyzed in terms of multicomponent fluorescence lifetime decays with demanding requirements in terms of signal level (and therefore limited frame rate). Recently, the phasor approach has been proposed as a powerful alternative for fluorescence lifetime analysis of FLIM, ensemble, and single-molecule experiments. Here we discuss the advantages of combining phasor analysis with a new type of FLIM acquisition hardware presented previously, consisting of a high temporal and spatial resolution wide-field single-photon counting device (the H33D detector). Experimental data with live cells and quantum dots will be presented as an illustration of this new approach. PMID:21625298
A semi-automated technique for labeling and counting of apoptosing retinal cells
2014-01-01
Background Retinal ganglion cell (RGC) loss is one of the earliest and most important cellular changes in glaucoma. The DARC (Detection of Apoptosing Retinal Cells) technology enables in vivo real-time non-invasive imaging of single apoptosing retinal cells in animal models of glaucoma and Alzheimer’s disease. To date, apoptosing RGCs imaged using DARC have been counted manually. This is time-consuming, labour-intensive, vulnerable to bias, and has considerable inter- and intra-operator variability. Results A semi-automated algorithm was developed which enabled automated identification of apoptosing RGCs labeled with fluorescent Annexin-5 on DARC images. Automated analysis included a pre-processing stage involving local-luminance and local-contrast “gain control”, a “blob analysis” step to differentiate between cells, vessels and noise, and a method to exclude non-cell structures using specific combined ‘size’ and ‘aspect’ ratio criteria. Apoptosing retinal cells were counted by 3 masked operators, generating ‘Gold-standard’ mean manual cell counts, and were also counted using the newly developed automated algorithm. Comparison between automated cell counts and the mean manual cell counts on 66 DARC images showed significant correlation between the two methods (Pearson’s correlation coefficient 0.978 (p < 0.001), R Squared = 0.956. The Intraclass correlation coefficient was 0.986 (95% CI 0.977-0.991, p < 0.001), and Cronbach’s alpha measure of consistency = 0.986, confirming excellent correlation and consistency. No significant difference (p = 0.922, 95% CI: −5.53 to 6.10) was detected between the cell counts of the two methods. Conclusions The novel automated algorithm enabled accurate quantification of apoptosing RGCs that is highly comparable to manual counting, and appears to minimise operator-bias, whilst being both fast and reproducible. This may prove to be a valuable method of quantifying apoptosing retinal cells, with particular relevance to translation in the clinic, where a Phase I clinical trial of DARC in glaucoma patients is due to start shortly. PMID:24902592
Kul'chyns'kyi, Andriy B; Kyjenko, Valeriy M; Zukow, Walery; Popovych, Igor L
2017-01-01
We aim to analyze in bounds KJ Tracey's immunological homunculus conception the relationships between parameters of electroencephalogram (EEG) and heart rate variability (HRV), on the one hand, and the parameters of bhite blood cell count, on the other hand. In basal conditions in 23 men, patients with chronic pyelonephritis and cholecystitis in remission, recorded EEG ("NeuroCom Standard", KhAI Medica, Ukraine) and HRV ("Cardiolab+VSR", KhAI Medica, Ukraine). In portion of blood counted up white blood cell count. Revealed that canonical correlation between constellation EEG and HRV parameters form with blood level of leukocytes 0.92 (p<10-5), with relative content in white blood cell count stubnuclear neutrophiles 0.93 (p<10-5), segmentonucleary neutrophiles 0.89 (p<10-3), eosinophiles 0.87 (p=0.003), lymphocytes 0.77 (p<10-3) and with monocytes 0.75 (p=0.003). Parameters of white blood cell count significantly modulated by electrical activity some structures of central and autonomic nervous systems.
Diao, Yingying; Geng, Wenqing; Fan, Xuejie; Cui, Hualu; Sun, Hong; Jiang, Yongjun; Wang, Yanan; Sun, Amy; Shang, Hong
2015-08-19
During early HIV-1 infection (EHI), the interaction between the immune response and the virus determines disease progression. Although CD1c + myeloid dendritic cells (mDCs) can trigger the immune response, the relationship between CD1c + mDC alteration and disease progression has not yet been defined. EHI changes in CD1c + mDC counts, surface marker (CD40, CD86, CD83) expression, and IL-12 secretion were assessed by flow cytometry in 29 patients. When compared with the normal controls, patients with EHI displayed significantly lower CD1c + mDC counts and IL-12 secretion and increased surface markers. CD1c + mDC counts were positively correlated with CD4+ T cell counts and inversely associated with viral loads. IL-12 secretion was only positively associated with CD4+ T cell counts. Rapid progressors had lower counts, CD86 expression, and IL-12 secretion of CD1c + mDCs comparing with typical progressors. Kaplan-Meier analysis and Cox regression models suggested patients with low CD1c + mDC counts (<10 cells/μL) had a 4-fold higher risk of rapid disease progression than those with high CD1c + mDC counts. However, no relationship was found between surface markers or IL-12 secretion and disease progression. During EHI, patients with low CD1c + mDC counts were more likely to experience rapid disease progression than those with high CD1c + mDC counts.
Accuracy of semen counting chambers as determined by the use of latex beads.
Seaman, E K; Goluboff, E; BarChama, N; Fisch, H
1996-10-01
To assess the accuracy of the Hemacytometer (Hausser Scientific, Horsham, PA), Makler (Sefi-Medical Instrument, Haifa, Israel), Cell-VU (Millennium Sciences Inc., New York, NY), and Micro-Cell chambers (Conception Technologies, San Diego, CA) counting chambers. A solution containing a known concentration of latex beads was used as the standard to perform counts on the four different counting chambers. Bead counts for the four different chambers were compared with the bead counts of the standard solution. Variability within chambers also was determined. Mean bead concentrations for both the Cell-VU and Micro-Cell chambers were consistently similar to the bead concentration of the standard solution. Both the hemacytometer and the Makler chambers overestimated the actual bead concentration of the standard solution by as much as 50% and revealed significant interchamber variability. Our data revealed marked differences in the accuracy and reliability of the different counting chambers tested and emphasized the need for standardization and quality control of laboratory procedures.
NASA Astrophysics Data System (ADS)
Zhang, Guoqing; Lina, Liu
2018-02-01
An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.
Seyoum, Awoke; Ndlovu, Principal; Temesgen, Zewotir
2017-03-16
Adherence and CD4 cell count change measure the progression of the disease in HIV patients after the commencement of HAART. Lack of information about associated factors on adherence to HAART and CD4 cell count reduction is a challenge for the improvement of cells in HIV positive adults. The main objective of adopting joint modeling was to compare separate and joint models of longitudinal repeated measures in identifying long-term predictors of the two longitudinal outcomes: CD4 cell count and adherence to HAART. A longitudinal retrospective cohort study was conducted to examine the joint predictors of CD4 cell count change and adherence to HAART among HIV adult patients enrolled in the first 10 months of the year 2008 and followed-up to June 2012. Joint model was employed to determine joint predictors of two longitudinal response variables over time. Furthermore, the generalized linear mixed effect model had been used for specification of the marginal distribution, conditional to correlated random effect. A total of 792 adult HIV patients were studied to analyze the longitudinal joint model study. The result from this investigation revealed that age, weight, baseline CD4 cell count, ownership of cell phone, visiting times, marital status, residence area and level of disclosure of the disease to family members had significantly affected both outcomes. From the two-way interactions, time * owner of cell phone, time * sex, age * sex, age * level of education as well as time * level of education were significant for CD4 cell count change in the longitudinal data analysis. The multivariate joint model with linear predictor indicates that CD4 cell count change was positively correlated (p ≤ 0.0001) with adherence to HAART. Hence, as adherence to HAART increased, CD4 cell count also increased; and those patients who had significant CD4 cell count change at each visiting time had been encouraged to be good adherents. Joint model analysis was more parsimonious as compared to separate analysis, as it reduces type I error and subject-specific analysis improved its model fit. The joint model operates multivariate analysis simultaneously; and it has great power in parameter estimation. Developing joint model helps validate the observed correlation between the outcomes that have emerged from the association of intercepts. There should be a special attention and intervention for HIV positive adults, especially for those who had poor adherence and with low CD4 cell count change. The intervention may be important for pre-treatment counseling and awareness creation. The study also identified a group of patients who were with maximum risk of CD4 cell count change. It is suggested that this group of patients needs high intervention for counseling.
Normal CD4 Count Range among Healthy Nigerian Population in Ilorin.
Afolabi, J K; Fadeyi, A; Desalu, O O; Durotoye, I A; Fawibe, A E; Adeboye, M A N; Olawumi, H O; Babatunde, A S; Ernest, S K; Aderibigbe, S A; Saadu, R; Salami, A K; Aboyeji, A P
For the establishment and monitoring of the immune status, CD4 count is critical. To determine the CD4 count range of apparently healthy Nigerians resident in Ilorin and compare with the national value. An automated blood analyzer was used to determine the full blood count and CD4 count. The percentage of CD4 count was derived by using other variables. Of the 1205 participants, the reference CD4 count (percentage of CD4) range for adult was 400 to 1288 cells/mm 3 (19%-48%) and for children was 582 to 3652 cells/mm 3 (17%-50%). CD4 count and percentage of CD4 were significantly ( P = .001) higher in females than in males, and the CD4 count declined significantly with increasing age ( r = -.174, P ≤ .0001). The percentage of CD4 count shows less variation with age ( r = -.051, P = .076). Adult residents of Ilorin had significantly lower absolute mean CD4 count (808 ± 260) than that of the national reference values of 847.0 ± 307.0 cells/mm 3 ( P = .001). We therefore advocate the use of CD4 count range derived in this study is lower than that of the national reference values.
2011-01-01
Background It is unclear whether antiretroviral (ART) naive HIV-positive individuals with high CD4 counts have a raised mortality risk compared with the general population, but this is relevant for considering earlier initiation of antiretroviral therapy. Methods Pooling data from 23 European and North American cohorts, we calculated country-, age-, sex-, and year-standardised mortality ratios (SMRs), stratifying by risk group. Included patients had at least one pre-ART CD4 count above 350 cells/mm3. The association between CD4 count and death rate was evaluated using Poisson regression methods. Findings Of 40,830 patients contributing 80,682 person-years of follow up with CD4 count above 350 cells/mm3, 419 (1.0%) died. The SMRs (95% confidence interval) were 1.30 (1.06-1.58) in homosexual men, and 2.94 (2.28-3.73) and 9.37 (8.13-10.75) in the heterosexual and IDU risk groups respectively. CD4 count above 500 cells/mm3 was associated with a lower death rate than 350-499 cells/mm3: adjusted rate ratios (95% confidence intervals) for 500-699 cells/mm3 and above 700 cells/mm3 were 0.77 (0.61-0.95) and 0.66 (0.52-0.85) respectively. Interpretation In HIV-infected ART-naive patients with high CD4 counts, death rates were raised compared with the general population. In homosexual men this was modest, suggesting that a proportion of the increased risk in other groups is due to confounding by other factors. Even in this high CD4 count range, lower CD4 count was associated with raised mortality. PMID:20638118
Brudvig, Jean M; Swenson, Cheryl L
2015-12-01
Rapid and precise measurement of total and differential nucleated cell counts is a crucial diagnostic component of cavitary and synovial fluid analyses. The objectives of this study included (1) evaluation of reliability and precision of canine and equine fluid total nucleated cell count (TNCC) determined by the benchtop Abaxis VetScan HM5, in comparison with the automated reference instruments ADVIA 120 and the scil Vet abc, respectively, and (2) comparison of automated with manual canine differential nucleated cell counts. The TNCC and differential counts in canine pleural and peritoneal, and equine synovial fluids were determined on the Abaxis VetScan HM5 and compared with the ADVIA 120 and Vet abc analyzer, respectively. Statistical analyses included correlation, least squares fit linear regression, Passing-Bablok regression, and Bland-Altman difference plots. In addition, precision of the total cell count generated by the VetScan HM5 was determined. Agreement was excellent without significant constant or proportional bias for canine cavitary fluid TNCC. Automated and manual differential counts had R(2) < .5 for individual cell types (least squares fit linear regression). Equine synovial fluid TNCC agreed but with some bias due to the VetScan HM5 overestimating TNCC compared to the Vet abc. Intra-assay precision of the VetScan HM5 in 3 fluid samples was 2-31%. The Abaxis VetScan HM5 provided rapid, reliable TNCC for canine and equine fluid samples. The differential nucleated cell count should be verified microscopically as counts from the VetScan HM5 and also from the ADVIA 120 were often incorrect in canine fluid samples. © 2015 American Society for Veterinary Clinical Pathology.
White blood cell counting system
NASA Technical Reports Server (NTRS)
1972-01-01
The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.
Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting
Huang, Xiwei; Jiang, Yu; Liu, Xu; Xu, Hang; Han, Zhi; Rong, Hailong; Yang, Haiping; Yan, Mei; Yu, Hao
2016-01-01
A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS) image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT). However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR) processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR) and Convolutional Neural Network based SR (CNNSR). Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications. PMID:27827837
Ilyinskikh, N N; Zagromov, E J; Lepekhin, A V
1990-12-01
Patients with tick-borne encephalitis (TBE) had higher counts of red blood cells (RBC) with micronuclei. The majority of patients revealed decreased capacity of blood lymphoid cells for DNA repair except those with a 2-wave pattern of the course of disease; in the latter, the DNA repair was significantly higher than in healthy donors. Patients with TBE revealed lower T-lymphocyte counts due to a decrease in the amount of T-helper cells (the level of T-suppressors was elevated). The intensity of antibody production against TBE virus was significantly enhanced by termination of disease in the majority of patients. The count of natural killer cells was decreased, particularly at the initial stage of disease. At the time of admission to hospital the counts of RBC with micronuclei and of T-helper cells were in reverse proportion. At the terminal stage of disease the same correlation was noted between RBC counts with micronuclei and the antibody level. At the onset of disease a direct correlation was noted between DNA repair and B-lymphocyte and T-helper counts. At the final stage of disease the reverse correlation between the activity of DNA-repair systems and T-suppressor counts was registered. Three months after discharge from hospital, the indices of micronuclear test, natural killer cell activity, and DNA repair returned to normal.
NASA Astrophysics Data System (ADS)
Nur, M. J.; Kuhuwael, F.; Katu, S.; Mubin, H.; Halim, R.
2018-03-01
HIV infected patients characterized by decrease CD4 cell count, where lower CD4 count, has higher infection risk. In HIV patients with Lung, Tuberculosis co-infection showed increase CRP level concomitant with disease severity. This study attempts to analyze TB incidence in HIV cases by looking at CD4 cell count and CRP levels in HIV-infected subjects. For analyzing the CD4 cell count and CRP levels in HIV patient with and without Lung Tuberculosis co-infection in Wahidin Sudirohusodo Hospital. Conducted observational study with cross-sectional design on HIV subjects withand without Lung Tuberculosis co-infection in Wahidin Sudirohusodo Hospital from September 2016 to June 2017. Patients divided into HIV group without TB co-infection, and with TB co-infection. Each group will be assessed CRP levels, which considered low <5 mg/L and high >5 mg/L, whereas CD4 cell count, considered low <200 cell/mm3 and normal >200 cell/mm3. Results are considered significant if p-value<0.05. There were a significantly higher CRP levels (p<0.02) and lower CD4 counts (p<0.02) in HIV with TB co-infection and no significant relationship between CRP levels with aCD4 count in both groups.
NASA Astrophysics Data System (ADS)
Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua
2016-03-01
Pixelated photon counting detectors with energy discrimination capabilities are of increasing clinical interest for x-ray imaging. Such detectors, presently in clinical use for mammography and under development for breast tomosynthesis and spectral CT, usually employ in-pixel circuits based on crystalline silicon - a semiconductor material that is generally not well-suited for economic manufacture of large-area devices. One interesting alternative semiconductor is polycrystalline silicon (poly-Si), a thin-film technology capable of creating very large-area, monolithic devices. Similar to crystalline silicon, poly-Si allows implementation of the type of fast, complex, in-pixel circuitry required for photon counting - operating at processing speeds that are not possible with amorphous silicon (the material currently used for large-area, active matrix, flat-panel imagers). The pixel circuits of two-dimensional photon counting arrays are generally comprised of four stages: amplifier, comparator, clock generator and counter. The analog front-end (in particular, the amplifier) strongly influences performance and is therefore of interest to study. In this paper, the relationship between incident and output count rate of the analog front-end is explored under diagnostic imaging conditions for a promising poly-Si based design. The input to the amplifier is modeled in the time domain assuming a realistic input x-ray spectrum. Simulations of circuits based on poly-Si thin-film transistors are used to determine the resulting output count rate as a function of input count rate, energy discrimination threshold and operating conditions.
A system for counting fetal and maternal red blood cells.
Ge, Ji; Gong, Zheng; Chen, Jun; Liu, Jun; Nguyen, John; Yang, Zongyi; Wang, Chen; Sun, Yu
2014-12-01
The Kleihauer-Betke (KB) test is the standard method for quantitating fetal-maternal hemorrhage in maternal care. In hospitals, the KB test is performed by a certified technologist to count a minimum of 2000 fetal and maternal red blood cells (RBCs) on a blood smear. Manual counting suffers from inherent inconsistency and unreliability. This paper describes a system for automated counting and distinguishing fetal and maternal RBCs on clinical KB slides. A custom-adapted hardware platform is used for KB slide scanning and image capturing. Spatial-color pixel classification with spectral clustering is proposed to separate overlapping cells. Optimal clustering number and total cell number are obtained through maximizing cluster validity index. To accurately identify fetal RBCs from maternal RBCs, multiple features including cell size, roundness, gradient, and saturation difference between cell and whole slide are used in supervised learning to generate feature vectors, to tackle cell color, shape, and contrast variations across clinical KB slides. The results show that the automated system is capable of completing the counting of over 60,000 cells (versus ∼2000 by technologists) within 5 min (versus ∼15 min by technologists). The throughput is improved by approximately 90 times compared to manual reading by technologists. The counting results are highly accurate and correlate strongly with those from benchmarking flow cytometry measurement.
Torriani, F J; Freeman, W R; Macdonald, J C; Karavellas, M P; Durand, D M; Jeffrey, D D; Meylan, P R; Schrier, R D
2000-01-28
To determine predictors of clinical relapse of cytomegalovirus (CMV) end-organ disease in a cohort of 17 HIV-infected patients with healed and treated CMV retinitis (CMVR) who responded to HAART with an increase in CD4 cell counts to above 70 cells/mm3 and discontinued CMV maintenance therapy (MT). Seventeen patients were monitored for reactivation of retinitis. The CD4 cell counts, HIV RNA and peripheral blood mononuclear cell (PBMC) lymphoproliferative assays to CMV at 3 month intervals were compared between patients with and without reactivation of CMVR. Positive lymphoproliferative responses were defined as a stimulation index of 3 or greater. Five out of 17 (29%) patients experienced a recurrence of CMVR a mean of 14.5 months after stopping CMV MT and between 8 days and 10 months after CD4 cell counts fell below 50 cells/mm3. Median CD4 cell counts and plasma HIV RNA at reactivation were 37 cells/mm3 and 5.3 log10 copies/ml. Three patients recurred at a previously active site of the retina, one had contralateral CMVR, and one a recurrence of retinitis and pancreatitis simultaneously. Mean lymphoproliferative responses to CMV were 2.4 in patients with reactivation versus 21.0 stimulation index (SI) in patients without reactivation (P= 0.01). A model incorporating four variables (CD4 cell counts and HIV RNA at maintenance discontinuation, highest CD4 cell count, nadir HIV RNA and median lymphoproliferative responses) identified correctly 88% of patients with and without reactivation. CMV disease recurs after virological and immunological failure of HAART if CD4 cell counts drop below 50. In this situation, anti-CMV agents should be resumed before clinical reactivation ensues, because of the risk of contralateral retinal involvement and systemic disease.
Hanning, Uta; Husstedt, Ingo W; Niederstadt, Thomas-Ulrich; Evers, Stefan; Heindel, Walter; Kloska, Stephan P
2011-09-01
The aim of this study was to assess the relationship between immune state and cerebral signal intensity abnormalities (SIAs) on T2-weighted magnetic resonance images in subjects with human immunodeficiency virus type 1 infection and highly active antiretroviral therapy. Thirty-two subjects underwent a total of 109 magnetic resonance studies. The presence of human immunodeficiency virus-associated neurocognitive disorder, categorized CD4(+) T lymphocyte count, and plasma viral load were assessed for relationship with the severity and interval change of SIAs for different anatomic locations of the brain. Subjects with multifocal patterns of SIAs had CD4(+) cell counts < 200 cells/μL in 66.0%, whereas subjects with diffuse patterns of SIAs had CD4(+) cell counts < 200 cells/μL in only 31.4% (P < .001). Subjects without SIAs in the basal ganglia had CD4(+) cell counts < 200 cells/μL in 37.0%, whereas subjects with minor and moderate SIAs in the basal ganglia had CD4(+) cell counts < 200 cells/μL in 78.3% and 80.0%, respectively (P < .005). The percentage of subjects with CD4(+) cell counts < 200 cells/μL was 85.7% when there were progressive periventricular SIA changes and 45.5% when periventricular SIA changes were stable in follow-up (P < .05). The presence and progression of cerebral SIAs on T2-weighted magnetic resonance images reflecting cerebral infection with human immunodeficiency virus are significantly related to impaired immune state as measured by CD4(+) cell count. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian
2016-03-01
Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.
Particle detection systems and methods
Morris, Christopher L.; Makela, Mark F.
2010-05-11
Techniques, apparatus and systems for detecting particles such as muons and neutrons. In one implementation, a particle detection system employs a plurality of drift cells, which can be for example sealed gas-filled drift tubes, arranged on sides of a volume to be scanned to track incoming and outgoing charged particles, such as cosmic ray-produced muons. The drift cells can include a neutron sensitive medium to enable concurrent counting of neutrons. The system can selectively detect devices or materials, such as iron, lead, gold, uranium, plutonium, and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can concurrently detect any unshielded neutron sources occupying the volume from neutrons emitted therefrom. If necessary, the drift cells can be used to also detect gamma rays. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.
A High Resolution Scale-of-four
DOE R&D Accomplishments Database
Fitch, V.
1949-08-25
A high resolution scale-of-four has been developed to be used in conjunction with the nuclear particle detection devices in applications where the counting rate is unusually high. Specifically, it is intended to precede the commercially available medium resolution scaling circuits and so decrease the resolving time of the counting system. The circuit will function reliably on continuously recurring pulses separated by less than 0.1 microseconds. It will resolve two pulses (occurring at a moderate repetition rate) which are spaced at 0.04 microseconds. A five-volt input signal is sufficient to actuate the device.
2012-01-01
Background Most clinical guidelines recommend that AIDS-free, HIV-infected persons with CD4 cell counts below 0.350 × 109 cells/L initiate combined antiretroviral therapy (cART), but the optimal CD4 cell count at which cART should be initiated remains a matter of debate. Objective To identify the optimal CD4 cell count at which cART should be initiated. Design Prospective observational data from the HIV-CAUSAL Collaboration and dynamic marginal structural models were used to compare cART initiation strategies for CD4 thresholds between 0.200 and 0.500 × 109 cells/L. Setting HIV clinics in Europe and the Veterans Health Administration system in the United States. Patients 20 971 HIV-infected, therapy-naive persons with baseline CD4 cell counts at or above 0.500 × 109 cells/L and no previous AIDS-defining illnesses, of whom 8392 had a CD4 cell count that decreased into the range of 0.200 to 0.499 × 109 cells/L and were included in the analysis. Measurements Hazard ratios and survival proportions for all-cause mortality and a combined end point of AIDS-defining illness or death. Results Compared with initiating cART at the CD4 cell count threshold of 0.500 × 109 cells/L, the mortality hazard ratio was 1.01 (95% CI, 0.84 to 1.22) for the 0.350 threshold and 1.20 (CI, 0.97 to 1.48) for the 0.200 threshold. The corresponding hazard ratios were 1.38 (CI, 1.23 to 1.56) and 1.90 (CI, 1.67 to 2.15), respectively, for the combined end point of AIDS-defining illness or death. Limitations CD4 cell count at cART initiation was not randomized. Residual confounding may exist. Conclusion Initiation of cART at a threshold CD4 count of 0.500 × 109 cells/L increases AIDS-free survival. However, mortality did not vary substantially with the use of CD4 thresholds between 0.300 and 0.500 ×109 cells/L. Primary Funding Source National Institutes of Health. PMID:21502648
Cain, Lauren E; Logan, Roger; Robins, James M; Sterne, Jonathan A C; Sabin, Caroline; Bansi, Loveleen; Justice, Amy; Goulet, Joseph; van Sighem, Ard; de Wolf, Frank; Bucher, Heiner C; von Wyl, Viktor; Esteve, Anna; Casabona, Jordi; del Amo, Julia; Moreno, Santiago; Seng, Remonie; Meyer, Laurence; Perez-Hoyos, Santiago; Muga, Roberto; Lodi, Sara; Lanoy, Emilie; Costagliola, Dominique; Hernan, Miguel A
2011-04-19
Most clinical guidelines recommend that AIDS-free, HIV-infected persons with CD4 cell counts below 0.350 × 10(9) cells/L initiate combined antiretroviral therapy (cART), but the optimal CD4 cell count at which cART should be initiated remains a matter of debate. To identify the optimal CD4 cell count at which cART should be initiated. Prospective observational data from the HIV-CAUSAL Collaboration and dynamic marginal structural models were used to compare cART initiation strategies for CD4 thresholds between 0.200 and 0.500 × 10(9) cells/L. HIV clinics in Europe and the Veterans Health Administration system in the United States. 20, 971 HIV-infected, therapy-naive persons with baseline CD4 cell counts at or above 0.500 × 10(9) cells/L and no previous AIDS-defining illnesses, of whom 8392 had a CD4 cell count that decreased into the range of 0.200 to 0.499 × 10(9) cells/L and were included in the analysis. Hazard ratios and survival proportions for all-cause mortality and a combined end point of AIDS-defining illness or death. Compared with initiating cART at the CD4 cell count threshold of 0.500 × 10(9) cells/L, the mortality hazard ratio was 1.01 (95% CI, 0.84 to 1.22) for the 0.350 threshold and 1.20 (CI, 0.97 to 1.48) for the 0.200 threshold. The corresponding hazard ratios were 1.38 (CI, 1.23 to 1.56) and 1.90 (CI, 1.67 to 2.15), respectively, for the combined end point of AIDS-defining illness or death. CD4 cell count at cART initiation was not randomized. Residual confounding may exist. Initiation of cART at a threshold CD4 count of 0.500 × 10(9) cells/L increases AIDS-free survival. However, mortality did not vary substantially with the use of CD4 thresholds between 0.300 and 0.500 × 10(9) cells/L.
Rapid enumeration of viable bacteria by image analysis
NASA Technical Reports Server (NTRS)
Singh, A.; Pyle, B. H.; McFeters, G. A.
1989-01-01
A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.
Physical activity among children: objective measurements using Fitbit One® and ActiGraph.
Hamari, Lotta; Kullberg, Tiina; Ruohonen, Jukka; Heinonen, Olli J; Díaz-Rodríguez, Natalia; Lilius, Johan; Pakarinen, Anni; Myllymäki, Annukka; Leppänen, Ville; Salanterä, Sanna
2017-04-20
Self-quantification of health parameters is becoming more popular; thus, the validity of the devices requires assessments. The aim of this study was to evaluate the validity of Fitbit One step counts (Fitbit Inc., San Francisco, CA, USA) against Actigraph wActisleep-BT step counts (ActiGraph, LLC, Pensacola, FL, USA) for measuring habitual physical activity among children. The study was implemented as a cross-sectional experimental design in which participants carried two waist-worn activity monitors for five consecutive days. The participants were chosen with a purposive sampling from three fourth grade classes (9-10 year olds) in two comprehensive schools. Altogether, there were 34 participants in the study. From these, eight participants were excluded from the analysis due to erroneous data. Primary outcome measures for step counts were Fitbit One and Actigraph wActisleep-BT. The supporting outcome measures were based on activity diaries and initial information sheets. Classical Bland-Altman plots were used for reporting the results. The average per-participant daily difference between the step counts from the two devices was 1937. The range was [116, 5052]. Fitbit One gave higher step counts for all but the least active participant. According to a Bland-Altman plot, the hourly step counts had a relative large mean bias across participants (161 step counts). The differences were partially explained by activity intensity: higher intensity denoted higher differences, and light intensity denoted lower differences. Fitbit One step counts are comparable to Actigraph step counts in a sample of 9-10-year-old children engaged in habitual physical activity in sedentary and light physical activity intensities. However, in moderate-to-vigorous physical activity, Fitbit One gives higher step counts when compared to Actigraph.
Costagliola, Dominique; Lacombe, Jean-Marc; Ghosn, Jade; Delaugerre, Constance; Pialoux, Gilles; Cuzin, Lise; Launay, Odile; Ménard, Amélie; de Truchis, Pierre; Mary-Krause, Murielle; Weiss, Laurence; Delfraissy, Jean-François
2014-01-01
A key objective of combined antiretroviral therapy (cART) is to reach and maintain high CD4 cell counts to provide long-term protection against AIDS-defining opportunistic infections and malignancies, as well as other comorbidities. However, a high proportion of patients present late for care. Our objective was to assess CD4 cell count recovery up to seven years in naïve patients initiating cART with at least three drugs in usual clinical care. From the French Hospital Database on HIV, we selected naïve individuals initiating cART from 2000 with at least two years of follow-up. Participants were further required to have achieved viral load suppression by six months after initiating cART and were censored in case of virological failure. We calculated the proportion of patients (Kaplan-Meier estimates) who achieved CD4 recovery to >500/mm(3) according to baseline CD4 cell count. A total of 15,025 patients were analyzed with a median follow-up on ART of 65.5 months (IQR: 42.3-96.0). At cART initiation, the median age was 38.6 years (IQR: 32.2-46.0), 9734 (64.8%) were men, median CD4 cell count was 239 (IQR: 130-336) and 2668 (17.8%) had a prior AIDS event. RESULTS are presented in the Table 1. This study shows that CD4 cell counts continue to increase seven years after cART initiation, whatever the baseline CD4 cell count. Failing to achieve CD4 recovery with continuous viral load suppression is rare for naïve patients initiating cART in routine clinical practice, but takes substantially longer in patients who initiate antiretroviral therapy at low CD4 cell counts.
Technical comparison of four different extracorporeal photopheresis systems.
Brosig, Andreas; Hähnel, Viola; Orsó, Evelyn; Wolff, Daniel; Holler, Ernst; Ahrens, Norbert
2016-10-01
Extracorporeal photopheresis (ECP) is a therapeutic technique that combines leukapheresis and ultraviolet (UV)A irradiation of the leukapheresate after 8-methoxypsoralen treatment with subsequent retransfusion. It can be achieved with a single device (online) or by combining an apheresis machine with a separate UVA light source (offline). The comparability of both established methods is unknown. In a prospective setting, four ECP systems were evaluated: one with integrated UVA irradiation for online ECP (Therakos) and three with external UVA irradiation for offline ECP (Amicus, Optia, and Cobe Spectra). Apheresis variables and cell counts were determined by methods including flow cytometry. The duration of apheresis ranged from 120 minutes (Amicus, Optia) to 275 minutes (Therakos). Mononuclear cell (MNC) counts in the treatment bags were comparable between offline ECP methods (median, 57 × 10 8 - 66 × 10 8 ) and lower for online ECP (14 × 10 8 ). CD16+ monocytes were abundant in online ECP (82%) but rarer in offline ECP (median, 14% - 19%). Hematocrit ranged from 0.1% (Therakos) to 8% (Amicus). There were no side effects in any patients. All offline ECP systems studied yielded comparable cellular compositions and highly enriched populations of MNCs. In contrast, white blood cells from online ECP displayed enrichment of nonclassical monocytes. The relevance of these findings is unknown as there is no established biomarker to predict the therapeutic efficacy of these procedures. © 2016 AABB.
Nasi, Milena; De Biasi, Sara; Bianchini, Elena; Gibellini, Lara; Pinti, Marcello; Scacchetti, Tiziana; Trenti, Tommaso; Borghi, Vanni; Mussini, Cristina; Cossarizza, Andrea
2015-01-01
An accurate and affordable CD4+ T cells count is an essential tool in the fight against HIV/AIDS. Flow cytometry (FCM) is the "gold standard" for counting such cells, but this technique is expensive and requires sophisticated equipment, temperature-sensitive monoclonal antibodies (mAbs) and trained personnel. The lack of access to technical support and quality assurance programs thus limits the use of FCM in resource-constrained countries. We have tested the accuracy, the precision and the carry-over contamination of Partec CyFlow MiniPOC, a portable and economically affordable flow cytometer designed for CD4+ count and percentage, used along with the "CD4% Count Kit-Dry". Venous blood from 59 adult HIV+ patients (age: 25-58 years; 43 males and 16 females) was collected and stained with the "MiniPOC CD4% Count Kit-Dry". CD4+ count and percentage were then determined in triplicate by the CyFlow MiniPOC. In parallel, CD4 count was performed using mAbs and a CyFlow Counter, or by a dual platform system (from Beckman Coulter) based upon Cytomic FC500 ("Cytostat tetrachrome kit" for mAbs) and Coulter HmX Hematology Analyzer (for absolute cell count). The accuracy of CyFlow MiniPOC against Cytomic FC500 showed a correlation coefficient (CC) of 0.98 and 0.97 for CD4+ count and percentage, respectively. The accuracy of CyFlow MiniPOC against CyFlow Counter showed a CC of 0.99 and 0.99 for CD4 T cell count and percentage, respectively. CyFlow MiniPOC showed an excellent repeatability: CD4+ cell count and percentage were analyzed on two instruments, with an intra-assay precision below ± 5% deviation. Finally, there was no carry-over contamination for samples at all CD4 values, regardless of their position in the sequence of analysis. The cost-effective CyFlow MiniPOC produces rapid, reliable and accurate results that are fully comparable with those from highly expensive dual platform systems.
Validation of an inertial measurement unit for the measurement of jump count and height.
MacDonald, Kerry; Bahr, Roald; Baltich, Jennifer; Whittaker, Jackie L; Meeuwisse, Willem H
2017-05-01
To validate the use of an inertial measurement unit (IMU) for the collection of total jump count and assess the validity of an IMU for the measurement of jump height against 3-D motion analysis. Cross sectional validation study. 3D motion-capture laboratory and field based settings. Thirteen elite adolescent volleyball players. Participants performed structured drills, played a 4 set volleyball match and performed twelve counter movement jumps. Jump counts from structured drills and match play were validated against visual count from recorded video. Jump height during the counter movement jumps was validated against concurrent 3-D motion-capture data. The IMU device captured more total jumps (1032) than visual inspection (977) during match play. During structured practice, device jump count sensitivity was strong (96.8%) while specificity was perfect (100%). The IMU underestimated jump height compared to 3D motion-capture with mean differences for maximal and submaximal jumps of 2.5 cm (95%CI: 1.3 to 3.8) and 4.1 cm (3.1-5.1), respectively. The IMU offers a valid measuring tool for jump count. Although the IMU underestimates maximal and submaximal jump height, our findings demonstrate its practical utility for field-based measurement of jump load. Copyright © 2016 Elsevier Ltd. All rights reserved.
Single photon detection in a waveguide-coupled Ge-on-Si lateral avalanche photodiode.
Martinez, Nicholas J D; Gehl, Michael; Derose, Christopher T; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S
2017-07-10
We examine gated-Geiger mode operation of an integrated waveguide-coupled Ge-on-Si lateral avalanche photodiode (APD) and demonstrate single photon detection at low dark count for this mode of operation. Our integrated waveguide-coupled APD is fabricated using a selective epitaxial Ge-on-Si growth process resulting in a separate absorption and charge multiplication (SACM) design compatible with our silicon photonics platform. Single photon detection efficiency and dark count rate is measured as a function of temperature in order to understand and optimize performance characteristics in this device. We report single photon detection of 5.27% at 1310 nm and a dark count rate of 534 kHz at 80 K for a Ge-on-Si single photon avalanche diode. Dark count rate is the lowest for a Ge-on-Si single photon detector in this range of temperatures while maintaining competitive detection efficiency. A jitter of 105 ps was measured for this device.
Optimal staining methods for delineation of cortical areas and neuron counts in human brains.
Uylings, H B; Zilles, K; Rajkowska, G
1999-04-01
For cytoarchitectonic delineation of cortical areas in human brain, the Gallyas staining for somata with its sharp contrast between cell bodies and neuropil is preferable to the classical Nissl staining, the more so when an image analysis system is used. This Gallyas staining, however, does not appear to be appropriate for counting neuron numbers in pertinent brain areas, due to the lack of distinct cytological features between small neurons and glial cells. For cell counting Nissl is preferable. In an optimal design for cell counting at least both the Gallyas and the Nissl staining must be applied, the former staining for cytoarchitectural delineaton of cortical areas and the latter for counting the number of neurons in the pertinent cortical areas. Copyright 1999 Academic Press.
Yang, Di; Zhao, Hongxin; Gao, Guiju; Wei, Kai; Zhang, Li; Han, Ning; Xiao, Jiang; Li, Xin; Wang, Fang; Liang, Hongyuan; Zhang, Wei; Wu, Liang
2014-12-01
To explore the relationship between CD4(+) T lymphocyte cell count and prognosis as well as healing of the surgical incision in HIV/AIDS patients who had received operation. Data were collected and analysed retrospectively from 234 HIV/AIDS patients hospitalized at the Beijing Ditan hospital who underwent operation between January 2008 and December 2012. Following factors were taken into consideration that including:age, gender, time and where that anti-HIV(+) was diagnosed, CD4(+)T lymphocyte cell count at the time of operation, part of the body that being operated, typology of incision, different levels of healing on the surgical incision, infection at the incision site, post-operative complications and the prognosis, etc. Wilcoxon rank sum test, χ(2) test, Kruskal-Wallis H test and Spearman rank correlation were used for statistical analysis to compare the different levels on healing of the incision in relation to the different CD4(+)T lymphocyte cell counts. Rates of level A healing under different CD4(+)T cell counts were also compared. 1) Among the 234 patients including 125 males and 109 females, the average age was 36.17±11.56 years old. Time after discovery of anti-HIV(+)was between 0 and 204 months. The medium CD4(+)T cell count was 388.5 cell/µl; 23.93% of the patients having CD4(+)T lymphocyte cell counts as <200 cell/µl. 2) 7.26% of the operations were emergent. There were 23 different organs affected at the time of operation, due to 48 different kinds of illness. 21.37% of the operations belonged to class I incision, 49.57% was class II incision and 29.06% was class III incision. 86.32% of the incisions resulted in level A healing, 12.51% resulted in level B and 1.71% in level C. 4.27% of the patients developed post-operative complications. Differences between level A healing and level B or C healing in terms of CD4(+)T lymphocyte cell count were not significant (P > 0.05). There was no statistically significant difference on the CD4(+) T lymphocyte count in patients with or without postoperative complications. Difference of the HIV infection time was also not statistically significant between the two groups of patients. Rate of level A healing for the different CD4(+)T lymphocyte cell count was not significant (P > 0.05). Healing of the incision did not show significant correlation with CD4(+) T lymphocyte cell count, duration of antiretroviral therapy or the time that HIV infection was discovered (P > 0.05). As long as both the in/exclusion criteria were strictly followed, prognosis for operation on HIV/AIDS seemed to be generally good. Low CD4(+)T lymphocyte cell count should not be taken as a exclusion criteria for operation on HIV/AIDS patients.
Ceppi, Francesco; Rivers, Julie; Annesley, Colleen; Pinto, Navin; Park, Julie R; Lindgren, Catherine; Mgebroff, Stephanie; Linn, Naomi; Delaney, Meghan; Gardner, Rebecca A
2018-06-01
The first step in the production of chimeric antigen receptor T cells is the collection of autologous T cells using apheresis technology. The procedure is technically challenging, because patients often have low leukocyte counts and are heavily pretreated with multiple lines of chemotherapy, marrow transplantation, and/or radiotherapy. Here, we report our experience of collecting T lymphocytes for chimeric antigen receptor T-cell manufacturing in pediatric and young adult patients with leukemia, non-Hodgkin lymphoma, or neuroblastoma. Apheresis procedures were performed on a COBE Spectra machine using the mononuclear cell program, with a collection target of 1 × 10 9 total mononuclear cells per kilogram. Data were collected regarding preapheresis and postapheresis blood counts, apheresis parameters, products, and adverse events. Ninety-nine patients (ages 1.3-25.7 years) and 102 apheresis events were available for analysis. Patients underwent apheresis at a variety of absolute lymphocyte cell counts, with a median absolute lymphocyte count of 944 cells/μL (range, 142-6944 cells/μL). Twenty-two patients (21.6%) had absolute lymphocyte counts less than 500 cells/μL. The mononuclear cell target was obtained in 100% of all apheresis harvests, and chimeric antigen receptor T-cell production was possible from the majority of collections (94%). Mononuclear cell collection efficiency was 65.4%, and T-lymphocyte collection efficiency was 83.4%. Ten patients (9.8%) presented with minor adverse events during the 102 apheresis procedures, with one exception of a severe allergy. Mononuclear cell apheresis for chimeric antigen receptor T-cell therapy is well tolerated and safe, and it is possible to obtain an adequate quantity of CD3+ lymphocytes for chimeric antigen receptor T-cell manufacturing in heavily pretreated patients who have low lymphocyte counts. © 2018 AABB.
Butler, W B
1984-08-15
A procedure is described for preparing nuclei from cells in monolayer culture so that they may be counted using an electronic particle counter. It takes only 10 to 15 min, and consists of swelling the cells in hypotonic buffer and then lysing them with the quaternary ammonium salt, ethylhexadecyldimethylammonium bromide. The cells are completely lysed, yielding a suspension of clean single nuclei which is stable, free of debris, and easily counted. The method was developed for a cell line of epithelial origin (MCF-7), which is often difficult to trypsinize to single cells. It works equally well at all cell densities up to and beyond confluence, and has been used with a variety of cells in culture, including 3T3 cells, bovine macrophages, rat mammary epithelial cells, mouse mammary tumor cell lines, and human fibroblasts. The size of the nuclei produced by this procedure is related to their DNA content, and the method is thus suitable for following cultures of synchronized cells through the cell cycle, and for performing differential counts of cells with substantial differences in DNA content.
NASA Astrophysics Data System (ADS)
Buongiorno, J.; Lloyd, K. G.; Shumaker, A.; Schippers, A.; Webster, G.; Weightman, A.; Turner, S.
2015-12-01
Nearly 75% of the Earth's surface is covered by marine sediment that is home to an estimated 2.9 x 1029 microbial cells. A substantial impediment to understanding the abundance and distribution of cells within marine sediment is the lack of a consistent and reliable method for their taxon-specific quantification. Catalyzed reporter fluorescent in situ hybridization (CARD-FISH) provides taxon-specific enumeration, but this process requires passing a large enzyme through cell membranes, decreasing its precision relative to general cell counts using a small DNA stain. In 2015, Yamaguchi et al. developed FISH hybridization chain reaction (FISH-HCR) as an in situ whole cell detection method for environmental microorganisms. FISH-HCR amplifies the fluorescent signal, as does CARD-FISH, but it allows for milder cell permeation methods that might prevent yield loss. To compare FISH-HCR to CARD-FISH, we examined bacteria and archaea cell counts within two sediment cores, Lille Belt (~78 meters deep) and Landsort Deep (90 meters deep), which were retrieved from the Baltic Sea Basin during IODP Expedition 347. Preliminary analysis shows that CARD-FISH counts are below the quantification limit for most depths across both cores. By contrast, quantification of cells was possible with FISH-HCR in all examined depths. When quantification with CARD-FISH was above the limit of detection, counts with FISH-HCR were up to 11 fold higher for Bacteria and 3 fold higher for Archaea from the same sediment sample. Further, FISH-HCR counts follow the trends of on board counts nicely, indicating that FISH-HCR may better reflect the cellular abundance within marine sediment than other quantification methods, including qPCR. Using FISH-HCR, we found that archaeal cell counts were on average greater than bacterial cell counts, but within the same order of magnitude.
Mandal, Rupali; Mondal, Krishnendu; Datta, Saikat; Chakrabarti, Indranil; Giri, Amita; Goswami, Bidyut Krishna
2015-12-01
HIV/AIDS is a major health burden worldwide. India bears the third highest HIV-patients load globally. In the Darjeeling district, HIV-prevalence is >1% with very little known about the profile of HIV-lymphadenopathy. The aim of this study was to identify the different causes of peripheral lymphadenopathy among HIV-infected patients in this region, correlate them with CD4+ T-cell counts and formulate some common clinico-haematological parameters as potential predictors of CD4+ T-cell count. In the present study, 76 cases were evaluated. Fine Needle Aspiration Cytology (FNAC) was performed as an out-patient procedure in the Department of Pathology. Smears were stained routinely with Haematoxylin-Eosin and Leishman stains. ZN stains were done when indicated by the cytological findings. Immediate CD4+ T-cell count was obtained by referring the patients to the Anti-retroviral therapy centre. Cytological diagnoses included tuberculosis (82.9%), reactive hyperplasia (6.6%), nonspecific granulomatous lesions (3.9%), non-Hodgkin lymphoma (2.6%), histoplasmosis (2.6%) and simultaneous filariasis with toxoplasmosis (1.3%). Statistically, the opportunistic infections and lymphomas significantly concurred with a CD4+ T-cell count <350/μl. Likewise, the number of enlarged lymph nodes and absolute lymphocyte count (ALC) were found to be useful predictors of CD4+ T-cell counts. Lymph node cytology in HIV-infected patients is essential to identify opportunistic infections from neoplastic lesions and; to enable therapeutic strategies. Correlation of lesions with mean CD4+ T-cell count predicts personal immunity, stage of disease and disease activity. Furthermore, enlarged lymph node numbers and ALC can be surrogate markers of CD4+ T-cell count for monitoring the severity of the immune suppression in under-resourced countries like India. © 2015 Wiley Periodicals, Inc.
Falay, Mesude; Aktas, Server
2016-11-01
The present study aimed to determine circulating Endothelial Progenitor Cell (EPC) counts by multicolor flow cytometry in healthy individuals and diabetic subjects by means of forming an analysis procedure using a combination of monoclonal antibodies (moAbs), which would correctly detect the circulating EPC count. The circulating EPC count was detected in 40 healthy individuals (20 Female, 20 Male; age range: 26 - 50 years) and 30 Diabetes Mellitus (DM) patients (15 Female, 15 Male; age range: 42 - 55) by multicolor flow cytometry (FCM) in a single-tube panel consisting of 5 CD45/CD31/CD34/CD309/ SYTO® and 16 monoclonal antibodies. Circulating EPC count was 11.33 (7.89 - 15.25) cells/µL in the healthy control group and 4.80 (0.70 - 10.85) cells/µL in the DM group. EPC counts were significantly lower in DM cases that developed coronary artery disease (53.3%) as compared to those that did not (p < 0.001). In the present study, we describe a method that identifies circulating EPC counts by multicolor flow cytometry in a single tube and determines the circulating EPC count in healthy individuals. This is the first study conducted on EPC count in Turkish population. We think that the EPC count found in the present study will be a guide for future studies.
Kitchener, Henry C; Gittins, Matthew; Desai, Mina; Smith, John H F; Cook, Gary; Roberts, Chris; Turnbull, Lesley
2015-03-01
Liquid-based cytology (LBC) for cervical screening would benefit from laboratory practice guidelines that define specimen adequacy for reporting of slides. The evidence base required to define cell adequacy should incorporate both ThinPrep™ (TP; Hologic, Inc., Bedford, MA, USA) and SurePath™ (SP; BD Diagnostics, Burlington, NC, USA), the two LBC systems used in the UK cervical screening programmes. The objectives of this study were to determine (1) current practice for reporting LBC in England, Wales and Scotland, (2) a reproducible method for cell counting, (3) the cellularity of slides classified as inadequate, negative or abnormal and (4) the impact of varying cellularity on the likelihood of detecting cytological abnormalities. The study involved four separate arms to pursue each of the four objectives. (1) A questionnaire survey of laboratories was conducted. (2) A standard counting protocol was developed and used by three experienced cytopathologists to determine a reliable and reproducible cell counting method. (3) Slide sets which included a range of cytological abnormalities were each sent to three laboratories for cell counting to study the correlation between cell counts and reported cytological outcomes. (4) Dilution of LBC samples by fluid only (unmixed) or by dilution with a sample containing normal cells (mixed) was performed to study the impact on reporting of reducing either the total cell count or the relative proportion of abnormal to normal cells. The study was conducted within the cervical screening programmes in England, Wales and Scotland, using routinely obtained cervical screening samples, and in 56 participating NHS cervical cytology laboratories. The study involved only routinely obtained cervical screening samples. There was no clinical intervention. The main outcome measures were (1) reliability of counting method, (2) correlation of reported cytology grades with cellularity and (3) levels of detection of abnormal cells in progressively diluted cervical samples. Laboratory practice varied in terms of threshold of cellular adequacy and of morphological markers of adequacy. While SP laboratories generally used a minimum acceptable cell count (MACC) of 15,000, the MACC employed by TP laboratories varied between 5000 and 15,000. The cell counting study showed that a standard protocol achieved moderate to strong inter-rater reproducibility. Analysis of slide reporting from laboratories revealed that a large proportion of the samples reported as inadequate had cell counts above a threshold of 15,000 for SP, and 5000 and 10,000 for TP. Inter-rater unanimity was greater among more cellular preparations. Dilution studies demonstrated greater detection of abnormalities in slides with counts above the MACC and among slides with more than 25 dyskaryotic cells. Variation in laboratory practice demonstrates a requirement for evidence-based standards for designating a MACC. This study has indicated that a MACC of 15,000 and 5000 for SP and TP, respectively, achieves a balance in terms of maintaining sensitivity and low inadequacy rates. The findings of this study should inform the development of laboratory practice guidelines. The National Institute for Health Research Health Technology Assessment programme.
Dorrucci, Maria; Rezza, Giovanni; Porter, Kholoud; Phillips, Andrew
2007-02-15
To determine whether early postseroconversion CD4 cell counts and human immunodeficiency virus (HIV) loads have changed over time. Our analysis was based on 22 cohorts of people with known dates of seroconversion from Europe, Australia, and Canada (Concerted Action on Seroconversion to AIDS and Death in Europe Collaboration). We focused on individuals seroconverting between 1985 and 2002 who had the first CD4 cell count (n=3687) or HIV load (n=1584) measured within 2 years of seroconversion and before antiretroviral use. Linear regression models were used to assess time trends in postseroconversion CD4 cell count and HIV load. Trends in time to key thresholds were also assessed, using survival analysis. The overall median initial CD4 cell count was 570 cells/ microL (interquartile range [IQR], 413-780 cells/ microL). The median initial HIV load was 35,542 copies/mL (IQR, 7600-153,050 copies/mL; on log(10) scale, 3.9-5.2 log(10) copies/mL). The postseroconversion CD4 cell count changed by an average of -6.33 cells/ microL/year (95% confidence interval [CI], -8.47 to -4.20 cells/ microL/year; P<.001), whereas an increase was observed in log(10) HIV load (+0.044 log(10) copies/mL/year; 95% CI, +0.034 to +0.053 log(10) copies/mL/year). These trends remained after adjusting for potential confounders. The probability of progressing to a CD4 cell count of <500 cells/ microL by 24 months from seroconversion increased from 0.66 (95% CI, 0.63-0.69) for individuals who seroconverted before 1991 to 0.80 (95% CI, 0.75-0.84) for those who seroconverted during 1999-2002. These data suggest that, in Europe, there has been a trend of decrease in the early CD4 cell count and of increase in the early HIV load. Additional research will be necessary to determine whether similar trends exist in other geographical areas.
An active drop counting device using condenser microphone for superheated emulsion detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Das, Mala; Marick, C.; Kanjilal, D.
2008-11-15
An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrummore » of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.« less
An active drop counting device using condenser microphone for superheated emulsion detector
NASA Astrophysics Data System (ADS)
Das, Mala; Arya, A. S.; Marick, C.; Kanjilal, D.; Saha, S.
2008-11-01
An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of C252f fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of C252f. Frequency analysis of the detected signals was also carried out.
Howell, W.D.
1957-08-20
An apparatus for automatically recording the results of counting operations on trains of electrical pulses is described. The disadvantages of prior devices utilizing the two common methods of obtaining the count rate are overcome by this apparatus; in the case of time controlled operation, the disclosed system automatically records amy information stored by the scaler but not transferred to the printer at the end of the predetermined time controlled operations and, in the case of count controlled operation, provision is made to prevent a weak sample from occupying the apparatus for an excessively long period of time.
Evans, William
2017-11-01
Positive cancer patient outcomes, including increased time to recurrent events, have been associated with increased counts and function of natural killer (NK) cells. NK cell counts and function are elevated following acute exercise, and the generally accepted mechanism of increased recruitment suggests that binding of epinephrine releases NK cells from endothelial tissue via decreases in adhesion molecules following. I propose that blood flow-induced shear stress may also play a role in NK cell recruitment from the endothelium. Additionally, shear stress may play a role in improving NK cell function by decreasing oxidative stress. The relationship between shear stress and NK cell count and function can be tested by utilizing exercise and local heating with cuff inflation. If shear stress does play an important role, NK cell count and function will be improved in the non-cuffed exercise group, but not the cuffed limb. This paper will explore the mechanisms potentially explaining exercise-induced improvements in NK cell count and function, and propose a model for investigating these mechanisms. This mechanistic insight could aid in providing a novel, safe, relatively inexpensive, and non-invasive target for immunotherapy in cancer patients. Copyright © 2017. Published by Elsevier Ltd.
Waters, L; Fisher, M; Anderson, J; Wood, C; Delpech, V; Hill, T; Walsh, J; Orkin, C; Bansi, L; Gompels, M; Phillips, A; Johnson, M; Gilson, R; Easterbrook, P; Leen, C; Porter, K; Gazzard, B; Sabin, C
2011-05-01
We investigated whether adverse responses to highly active antiretroviral therapy (HAART) associated with late HIV presentation are secondary to low CD4 cell count per se or other confounding factors. A longitudinal analysis of the UK Collaborative HIV Cohort (CHIC) Study of individuals starting HAART in 1998-2007 was carried out, comparing late presenters (presenting/starting HAART at a CD4 count <200 cells/μL) with late starters (presenting at a CD4 count>350 cells/μL; starting HAART at a CD4 count<200 cells/μL), using 'ideal starters' (presenting at a CD4 count>350 cells/μL; starting HAART at a CD4 count of 200-350 cells/μL) as a comparator. Virological, immunological and clinical (new AIDS event/death) outcomes at 48 and 96 weeks were analysed, with the analysis being limited to those remaining on HAART for>3 months. A total of 4978 of 9095 individuals starting first-line HAART with HIV RNA>500 HIV-1 RNA copies/mL were included in the analysis: 2741 late presenters, 947 late starters and 1290 ideal starters. Late presenters were more commonly female, heterosexual and Black African. Most started nonnucleoside reverse transcriptase inhibitors (NNRTIs); 48-week virological suppression was similar in late presenters and starters (and marginally lower than in ideal starters); by week 96 differences were reduced and nonsignificant. The median CD4 cell count increase in late presenters was significantly lower than that in late starters (weeks 48 and 96). During year 1, new clinical events were more frequent for late presenters [odds ratio (OR) 2.04; 95% confidence interval (CI) 1.19-3.51; P=0.01]; by year 2, event rates were similar in all groups. Amongst patients who initiate, and remain on, HAART, late presentation is associated with lower rates of virological suppression, blunted CD4 cell count increases and more clinical events compared with late starters in year 1, but similar clinical and immunological outcomes by year 2 to those of both late and ideal starters. Differences between late presenters and late starters suggest that factors other than CD4 cell count alone may be driving adverse treatment outcomes in late-presenting individuals.
[Effect of intravenous treatment with OK-432 on the bone marrow in patients with lung cancer].
Fujii, M; Ishikawa, M; Toki, H
1984-03-01
We studied effects of OK-432 on the bone marrow and peripheral blood cells of lung cancer patients. The nuclear cell count of bone marrow increased in 5 to 7 patients upon intravenous treatment with OK-432 compared with 3 of 6 patients who were intramuscularly treated with OK-432. Serial neutrophil counts of bone marrow increased in all 7 patients treated intravenously compared with 3 of 6 patients treated intramuscularly. The mean nuclear cell count or the serial neutrophil count of bone marrow in intravenously treated patients was significantly higher than the pretreatment values (p less than 0.001). In the peripheral blood picture, the difference in white blood cells or neutrophils before and after intravenous treatment was also statistically significant (p less than 0.01). There was no change in the erythrocytic series count of bone marrow and the hemoglobin count. Our results support the superiority of intravenous OK-432 treatment over intramuscular treatment in the growth-accelerating effect on bone marrow cells, especially regarding the neutrophil series.
Kul’chyns’kyi, Andriy B; Kyjenko, Valeriy M; Zukow, Walery; Popovych, Igor L
2017-01-01
Abstract We aim to analyze in bounds KJ Tracey’s immunological homunculus conception the relationships between parameters of electroencephalogram (EEG) and heart rate variability (HRV), on the one hand, and the parameters of bhite blood cell count, on the other hand. Methods In basal conditions in 23 men, patients with chronic pyelonephritis and cholecystitis in remission, recorded EEG (“NeuroCom Standard”, KhAI Medica, Ukraine) and HRV (“Cardiolab+VSR”, KhAI Medica, Ukraine). In portion of blood counted up white blood cell count. Results Revealed that canonical correlation between constellation EEG and HRV parameters form with blood level of leukocytes 0.92 (p<10-5), with relative content in white blood cell count stubnuclear neutrophiles 0.93 (p<10-5), segmentonucleary neutrophiles 0.89 (p<10-3), eosinophiles 0.87 (p=0.003), lymphocytes 0.77 (p<10-3) and with monocytes 0.75 (p=0.003). Conclusion Parameters of white blood cell count significantly modulated by electrical activity some structures of central and autonomic nervous systems. PMID:28730179
Microfluidic immunomagnetic cell separation from whole blood.
Bhuvanendran Nair Gourikutty, Sajay; Chang, Chia-Pin; Puiu, Poenar Daniel
2016-02-01
Immunomagnetic-based separation has become a viable technique for the separation of cells and biomolecules. Here we report on the design and analysis of a simple and efficient microfluidic device for high throughput and high efficiency capture of cells tagged with magnetic particles. This is made possible by using a microfluidic chip integrated with customized arrays of permanent magnets capable of creating large magnetic field gradients, which determine the effective capturing of the tagged cells. This method is based on manipulating the cells which are under the influence of a combination of magnetic and fluid dynamic forces in a fluid under laminar flow through a microfluidic chip. A finite element analysis (FEA) model is developed to analyze the cell separation process and predict its behavior, which is validated subsequently by the experimental results. The magnetic field gradients created by various arrangements of magnetic arrays have been simulated using FEA and the influence of these field gradients on cell separation has been studied with the design of our microfluidic chip. The proof-of-concept for the proposed technique is demonstrated by capturing white blood cells (WBCs) from whole human blood. CD45-conjugated magnetic particles were added into whole blood samples to label WBCs and the mixture was flown through our microfluidic device to separate the labeled cells. After the separation process, the remaining WBCs in the elute were counted to determine the capture efficiency, and it was found that more than 99.9% WBCs have been successfully separated from whole blood. The proposed design can be used for positive selection as well as for negative enrichment of rare cells. Copyright © 2015 Elsevier B.V. All rights reserved.
Kubínová, Zuzana
2014-01-01
Chloroplast number per cell is a frequently examined quantitative anatomical parameter, often estimated by counting chloroplast profiles in two-dimensional (2D) sections of mesophyll cells. However, a mesophyll cell is a three-dimensional (3D) structure and this has to be taken into account when quantifying its internal structure. We compared 2D and 3D approaches to chloroplast counting from different points of view: (i) in practical measurements of mesophyll cells of Norway spruce needles, (ii) in a 3D model of a mesophyll cell with chloroplasts, and (iii) using a theoretical analysis. We applied, for the first time, the stereological method of an optical disector based on counting chloroplasts in stacks of spruce needle optical cross-sections acquired by confocal laser-scanning microscopy. This estimate was compared with counting chloroplast profiles in 2D sections from the same stacks of sections. Comparing practical measurements of mesophyll cells, calculations performed in a 3D model of a cell with chloroplasts as well as a theoretical analysis showed that the 2D approach yielded biased results, while the underestimation could be up to 10-fold. We proved that the frequently used method for counting chloroplasts in a mesophyll cell by counting their profiles in 2D sections did not give correct results. We concluded that the present disector method can be efficiently used for unbiased estimation of chloroplast number per mesophyll cell. This should be the method of choice, especially in coniferous needles and leaves with mesophyll cells with lignified cell walls where maceration methods are difficult or impossible to use. PMID:24336344
21 CFR 864.8625 - Hematology quality control mixture.
Code of Federal Regulations, 2011 CFR
2011-04-01
... parameters such as white cell count (WBC), red cell count (RBC), platelet count (PLT), hemoglobin, hematocrit (HCT), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). (b) Classification. Class II (performance standards). [45 FR 60637, Sept. 12...
Buoro, Sabrina; Vavassori, Mauro; Pipitone, Silvia; Benegiamo, Anna; Lochis, Eleonora; Fumagalli, Sabina; Falanga, Anna; Marchetti, Marina; Crippa, Alberto; Ottomano, Cosimo; Lippi, Giuseppe
2015-10-01
Current haematology analysers have variable sensitivity and accuracy for counting nucleated red blood cells in samples with low values and in all those conditions characterised by altered sensitivity of red blood cells to the lysing process, such as in beta-thalassaemia or sickle-cell diseases and in neonates. The aim of our study was to evaluate the performance of the automated analyser XE-2100 at counting nucleated red blood cells in the above-mentioned three categories of subjects with potentially altered red blood cell lysis sensitivity and yet a need for accurate nucleated red blood cell counts. We measured nucleated red blood cell count by XE-2100 in peripheral blood samples of 187 subjects comprising 55 patients with beta-thalassaemia (40 major and 15 traits), 26 sickle-cell patients, 56 neonates and 50 normal subject. Results were compared with those obtained by optical microscopy. Agreement between average values of the two methods was estimated by means of Pearson's correlation and bias analysis, whereas diagnostic accuracy was estimated by analysis of receiver operating characteristic curves. The comparison between the two methods showed a Pearson's correlation of 0.99 (95% CI; 0.98-0.99; p<0.001) and bias of -0.61 (95% CI, -1.5-0.3). The area under the curve of the nucleated red blood cell count in all samples was 0.98 (95% CI, 0.96-1.00; p<0.001). Sub-analysis revealed an area under curve of 0.99 (95% CI, 0.98-1.00; p<0.001) for patients with thalassaemia, 0.94 (95% CI, 0.85-1.00; p<0.001) for patients with sickle cell anaemia, and 1.00 (95% CI, 1.0-1.0) for neonates. XE-2100 has excellent performance for nucleated red blood cell counting, especially in critical populations such as patients with haemoglobinopathies and neonates.
Correlation of CD4 counts with microalbuminuria in HIV patients
NASA Astrophysics Data System (ADS)
Bakri, S.; Haerani, R.; Hasyim, K.; Sudirman, K.; Tarukallo, N.
2018-03-01
One of the manifestations of kidney disease is Microalbuminuria (MA). CD4 T cells are cells that play a central role in immune protection, wherein HIV infections, they are the primary target of the virus. CD4 cells counts is an indirect reflection of the activity and viral load of HIV. This study aimed to determine the correlation of CD4 counts with MA in HIV patients. A cross-sectional with thedescriptive analytical study was in HIV patients >18 years old without a history of Diabetes Mellitus. The result of thestatistical test is significant if the value of p <0.05. The prevalence of MA in subjects with CD4 cell counts <200 cells/μl was 56.1%, and NA was 43.9%. On the other hand, in subjects with CD4 ≥ 200 cells/μl, the prevalence of MA was 3.4% and the prevalence of NA was 96%. In conclusion, there was a significant correlation of low count CD4 (CD4 <200 cells/μl) with microalbuminuria in HIV patients.
Frontiers of More than Moore in Bioelectronics and the Required Metrology Needs
NASA Astrophysics Data System (ADS)
Guiseppi-Elie, Anthony; Kotanen, Christian; Wilson, A. Nolan
2011-11-01
Silicon's intersection with biology is a premise inherent in Moore's prediction. Distinct from biologically inspired molecular logic and storage devices (more Moore) are the integration of solid state electronic devices with the soft condensed state of the body (more than Moore). Developments in biomolecular recognition events per sq. cm parallel those of Moore's Law. However, challenges continue in the area of "More than Moore". Two grand challenge problems must be addressed—the biocompatibility of synthetic materials with the myriad of tissue types within the human body and the interfacing of solid state micro- and nano-electronic devices with the electronics of biological systems. Electroconductive hydrogels have been developed as soft, condensed, biomimetic but otherwise inherently electronically conductive materials to address the challenge of interfacing solid state devices with the electronics of the body, which is predominantly ionic. Nano-templated interfaces via the oriented immobilization of single walled carbon nanotubes (SWCNTs) onto metallic electrodes have engendered reagentless, direct electron transfer between biological redox enzymes and solid state electrodes. In addressing these challenges, metrology needs and opportunities are found in such widely diverse areas as single molecule counting and addressing, sustainable power requirements such as the development of implantable biofuel cells for the deployment of implantable biochips, and new manufacturing paradigms to address plura-biology needs on solid state devices.
Background compensation for a radiation level monitor
Keefe, D.J.
1975-12-01
Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.
Microfluidic differential immunocapture biochip for specific leukocyte counting
Hassan, Umer; Watkins, Nicholas N; Reddy, Bobby; Damhorst, Gregory; Bashir, Rashid
2016-01-01
Enumerating specific cell types from whole blood can be very useful for research and diagnostic purposes—e.g., for counting of cD4 and cD8 t cells in HIV/aIDs diagnostics. We have developed a biosensor based on a differential immunocapture technology to enumerate specific cells in 30 min using 10 µl of blood. this paper provides a comprehensive stepwise protocol to replicate our biosensor for cD4 and cD8 cell counts. the biochip can also be adapted to enumerate other specific cell types such as somatic cells or cells from tissue or liquid biopsies. capture of other specific cells requires immobilization of their corresponding antibodies within the capture chamber. therefore, this protocol is useful for research into areas surrounding immunocapture-based biosensor development. the biosensor production requires 24 h, a one-time cell capture optimization takes 6–9 h, and the final cell counting experiment in a laboratory environment requires 30 min to complete. PMID:26963632
A simple method for quantifying jump loads in volleyball athletes.
Charlton, Paula C; Kenneally-Dabrowski, Claire; Sheppard, Jeremy; Spratford, Wayne
2017-03-01
Evaluate the validity of a commercially available wearable device, the Vert, for measuring vertical displacement and jump count in volleyball athletes. Propose a potential method of quantifying external load during training and match play within this population. Validation study. The ability of the Vert device to measure vertical displacement in male, junior elite volleyball athletes was assessed against reference standard laboratory motion analysis. The ability of the Vert device to count jumps during training and match-play was assessed via comparison with retrospective video analysis to determine precision and recall. A method of quantifying external load, known as the load index (LdIx) algorithm was proposed using the product of the jump count and average kinetic energy. Correlation between two separate Vert devices and three-dimensional trajectory data were good to excellent for all jump types performed (r=0.83-0.97), with a mean bias of between 3.57-4.28cm. When matched against jumps identified through video analysis, the Vert demonstrated excellent precision (0.995-1.000) evidenced by a low number of false positives. The number of false negatives identified with the Vert was higher resulting in lower recall values (0.814-0.930). The Vert is a commercially available tool that has potential for measuring vertical displacement and jump count in elite junior volleyball athletes without the need for time-consuming analysis and bespoke software. Subsequently, allowing the collected data to better quantify load using the proposed algorithm (LdIx). Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zeng, Jian
Microfluidic devices have been increasingly used in the past two decades for particle and cell manipulations in many chemical and biomedical applications. A variety of force fields have been demonstrated to control particle and cell transport in these devices including electric, magnetic, acoustic, and optical forces etc. Among these particle handling techniques, the magnetic approach provides clear advantages over others such as low cost, noninvasive, and free of fluid heating issues. However, the current knowledge of magnetic control of particle transport is still very limited, especially lacking is the handling of diamagnetic particle. This thesis is focused on the magnetic manipulation of diamagnetic particles and cells in ferrofluid flow through the use of a pair of permanent magnets. By varying the configuration of the two magnets, diverse operations of particles and cells is implemented in a straight microchannel that can potentially be integrated into lab-on-a-chip devices for various applications. First, an approach for embedding two, symmetrically positioned, repulsive permanent magnets about a straight rectangular microchannel in a PDMS-based microfluidic device is developed for particle focusing. Focusing particles and cells into a tight stream is often required in order for continuous detection, counting, and sorting. The closest distance between the magnets is limited only by the size of the magnets involved in the fabrication process. The device is used to implement and investigate the three-dimensional magnetic focusing of polystyrene particles in ferrofluid microflow with both top-view and side-view visualizations. The effects of flow speed and particle size on the particle focusing effectiveness are studied. This device is also applied to magnetically focus yeast cells in ferrofluid, which proves to be biocompatible as verified by cell viability test. In addition, an analytical model is developed and found to be able to predict the experimentally observed particle and cell focusing behaviors with reasonable agreement. Next, a simple magnetic technique to concentrate polystyrene particles and live yeast cells in ferrofluid flow through a straight rectangular microchannel is developed. Concentrating particles to a detectable level is often necessary in many applications. The magnetic field gradient is created by two attracting permanent magnets that are placed on the top and bottom of the planar microfluidic device and held in position by their natural attractive force. The effects of flow speed and magnet-magnet distance are studied and the device was applied for use for concentrating live yeast cells. The magnet-magnet distance is mainly controlled by the thickness of the device substrate and can be made small, providing a locally strengthened magnetic field as well as allowing for the use of dilute ferrofluid in the developed magnetic concentration technique. This advantage not only enables a magnetic/fluorescent label-free handling of diamagnetic particles but also renders such handling biocompatible. Lastly, a device is presented for a size-based continuous separation of particles through a straight rectangular microchannel. Particle separation is critical in many applications involving the sorting of cells. A first magnet is used for focusing the particle mixture into a single stream due to its relative close positioning with respect to the channel, thus creating a greater magnetic field magnitude. Then, a following magnet is used to displace the aligned particles to dissimilar flow paths by placing it farther away compared the first magnet, which provides a weaker magnetic field, therefore more sensitive towards the deflection of particles based on their size. The effects of both flow speed and separator magnet position are examined. The experimental data are found to fit well with analytical model predictions. This is followed by a study replacing the particles which are closely sized to that of live yeast cells and observe the separation of the cells from larger particles. Afterwards, a test for biocompatibility is confirmed.
Charge transfer in photorechargeable composite films of TiO2 and polyaniline
NASA Astrophysics Data System (ADS)
Nomiyama, Teruaki; Sasabe, Kenichi; Sakamoto, Kenta; Horie, Yuji
2015-07-01
A photorechargeable battery (PRB) is a photovoltaic device having an energy storage function in a single cell. The photoactive electrode of PRB is a bilayer film consisting of bare porous TiO2 and a TiO2-polyaniline (PANi) mixture that work as a photovoltaic current generator and an electrochemical energy storage by ion dedoping, respectively. To study the charge transfer between TiO2 and PANi, the photorechargeable quantum efficiency QE ([electron count on discharge]/[incident photon count on photocharge]) was measured by varying the thickness LS of the TiO2-PANi mixture. The quantum efficiency QEuv for UV photons had a maximum of ˜7% at LS ˜ 7 µm. The time constant τTP for the charge transfer was about 10-1 s, which was longer ten times or more than the lifetime of excited electrons within TiO2. These facts reveal that the main rate-limiting factor in the photocharging process is the charge transfer between TiO2 and PANi.
Quantum Biometrics with Retinal Photon Counting
NASA Astrophysics Data System (ADS)
Loulakis, M.; Blatsios, G.; Vrettou, C. S.; Kominis, I. K.
2017-10-01
It is known that the eye's scotopic photodetectors, rhodopsin molecules, and their associated phototransduction mechanism leading to light perception, are efficient single-photon counters. We here use the photon-counting principles of human rod vision to propose a secure quantum biometric identification based on the quantum-statistical properties of retinal photon detection. The photon path along the human eye until its detection by rod cells is modeled as a filter having a specific transmission coefficient. Precisely determining its value from the photodetection statistics registered by the conscious observer is a quantum parameter estimation problem that leads to a quantum secure identification method. The probabilities for false-positive and false-negative identification of this biometric technique can readily approach 10-10 and 10-4, respectively. The security of the biometric method can be further quantified by the physics of quantum measurements. An impostor must be able to perform quantum thermometry and quantum magnetometry with energy resolution better than 10-9ℏ , in order to foil the device by noninvasively monitoring the biometric activity of a user.
A portable and integrated instrument for cell manipulation by dielectrophoresis.
Burgarella, Sarah; Di Bari, Marco
2015-07-01
The physical manipulation of biological cells is a key point in the development of miniaturized systems for point-of-care analyses. Dielectrophoresis (DEP) has been reported by several laboratories as a promising method in biomedical research for label-free cell manipulation without physical contact, by exploiting the dielectric properties of cells suspended in a microfluidic sample, under the action of high-gradient electric fields. In view of a more extended use of DEP phenomena in lab-on-chip devices for point-of-care settings, we have developed a portable instrument, integrating on the same device the microfluidic biochip for cell manipulation and all the laboratory functions (i.e., DEP electric signal generation, microscopic observation of the biological sample under test and image acquisition) that are normally obtained by combining different nonportable standard laboratory instruments. The nonuniform electric field for cell manipulation on the biochip is generated by microelectrodes, patterned on the silicon substrate of microfluidic channels, using standard microfabrication techniques. Numerical modeling was performed to simulate the electric field distribution, quantify the DEP force, and optimize the geometry of the microelectrodes. The developed instrument includes an electronic board, which allows the control of the electric signal applied to electrodes necessary for DEP, and a miniaturized optical microscope system that allows visual inspection and eventually cell counting, as well as image and video recording. The system also includes the control software. The portable and integrated platform described in this work therefore represents a complete and innovative solution of applied research, suitable for many biological applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Real-time digital signal processing in multiphoton and time-resolved microscopy
NASA Astrophysics Data System (ADS)
Wilson, Jesse W.; Warren, Warren S.; Fischer, Martin C.
2016-03-01
The use of multiphoton interactions in biological tissue for imaging contrast requires highly sensitive optical measurements. These often involve signal processing and filtering steps between the photodetector and the data acquisition device, such as photon counting and lock-in amplification. These steps can be implemented as real-time digital signal processing (DSP) elements on field-programmable gate array (FPGA) devices, an approach that affords much greater flexibility than commercial photon counting or lock-in devices. We will present progress toward developing two new FPGA-based DSP devices for multiphoton and time-resolved microscopy applications. The first is a high-speed multiharmonic lock-in amplifier for transient absorption microscopy, which is being developed for real-time analysis of the intensity-dependence of melanin, with applications in vivo and ex vivo (noninvasive histopathology of melanoma and pigmented lesions). The second device is a kHz lock-in amplifier running on a low cost (50-200) development platform. It is our hope that these FPGA-based DSP devices will enable new, high-speed, low-cost applications in multiphoton and time-resolved microscopy.
Srasuebkul, Preeyaporn; Lim, Poh Lian; Lee, Man Po; Kumarasamy, Nagalingeswaran; Zhou, Jialun; Sirisanthana, Thira; Li, Patrick C. K.; Kamarulzaman, Adeeba; Oka, Shinichi; Phanuphak, Praphan; Vonthanak, Saphonn; Merati, Tuti P.; Chen, Yi-Ming A.; Sungkanuparph, Somnuek; Tau, Goa; Zhang, Fujie; Lee, Christopher K. C.; Ditangco, Rossana; Pujari, Sanjay; Choi, Jun Y.; Smith, Jeffery; Law, Matthew G.
2009-01-01
Objective The aim of our study was to develop, on the basis of simple clinical data, predictive short-term risk equations for AIDS or death in Asian patients infected with human immunodeficiency virus (HIV) who were included in the TREAT Asia HIV Observational Database. Methods Inclusion criteria were highly active antiretroviral therapy initiation and completion of required laboratory tests. Predictors of short-term AIDS or death were assessed using Poisson regression. Three different models were developed: a clinical model, a CD4 cell count model, and a CD4 cell count and HIV RNA level model. We separated patients into low-risk, high-risk, and very high-risk groups according to the key risk factors Identified. Results In the clinical model, patients with severe anemia or a body mass index (BMI; calculated as the weight in kilograms divided by the square of the height in meters) ≤18 were at very high risk, and patients who were aged <40 years or were male and had mild anemia were at high risk. In the CD4 cell count model, patients with a CD4 cell count <50 cells/µL, severe anemia, or a BMI ≤18 were at very high risk, and patients who had a CD4 cell count of 51–200 cells/µL, were aged <40 years, or were male and had mild anemia were at high risk. In the CD4 cell count and HIV RNA level model, patients with a CD4 cell count <50 cells/µL, a detectable viral load, severe anemia, or a BMI ≤18 were at very high risk, and patients with a CD4 cell count of 51–200 cells/µL and mild anemia were at high risk. The incidence of new AIDS or death in the clinical model was 1.3, 4.9, and 15.6 events per 100 person-years in the low-risk, high-risk, and very high-risk groups, respectively. In the CD4 cell count model the respective incidences were 0.9, 2.7, and 16.02 events per 100 person-years; in the CD4 cell count and HIV RNA level model, the respective incidences were 0.8, 1.8, and 6.2 events per 100 person-years. Conclusions These models are simple enough for widespread use in busy clinics and should allow clinicians to identify patients who are at high risk of AIDS or death in Asia and the Pacific region and in resource-poor settings. PMID:19226231
2012-01-01
Background Changes in CD4 cell counts are poorly documented in individuals with low or moderate-level viremia while on antiretroviral treatment (ART) in resource-limited settings. We assessed the impact of on-going HIV-RNA replication on CD4 cell count slopes in patients treated with a first-line combination ART. Method Naïve patients on a first-line ART regimen with at least two measures of HIV-RNA available after ART initiation were included in the study. The relationships between mean CD4 cell count change and HIV-RNA at 6 and 12 months after ART initiation (M6 and M12) were assessed by linear mixed models adjusted for gender, age, clinical stage and year of starting ART. Results 3,338 patients were included (14 cohorts, 64% female) and the group had the following characteristics: a median follow-up time of 1.6 years, a median age of 34 years, and a median CD4 cell count at ART initiation of 107 cells/μL. All patients with suppressed HIV-RNA at M12 had a continuous increase in CD4 cell count up to 18 months after treatment initiation. By contrast, any degree of HIV-RNA replication both at M6 and M12 was associated with a flat or a decreasing CD4 cell count slope. Multivariable analysis using HIV-RNA thresholds of 10,000 and 5,000 copies confirmed the significant effect of HIV-RNA on CD4 cell counts both at M6 and M12. Conclusion In routinely monitored patients on an NNRTI-based first-line ART, on-going low-level HIV-RNA replication was associated with a poor immune outcome in patients who had detectable levels of the virus after one year of ART. PMID:22742573
Photon-counting intensified random-access charge injection device
NASA Astrophysics Data System (ADS)
Norton, Timothy J.; Morrissey, Patrick F.; Haas, Patrick; Payne, Leslie J.; Carbone, Joseph; Kimble, Randy A.
1999-11-01
At NASA GSFC we are developing a high resolution solar-blind photon counting detector system for UV space based astronomy. The detector comprises a high gain MCP intensifier fiber- optically coupled to a charge injection device (CID). The detector system utilizes an FPGA based centroiding system to locate the center of photon events from the intensifier to high accuracy. The photon event addresses are passed via a PCI interface with a GPS derived time stamp inserted per frame to an integrating memory. Here we present imaging performance data which show resolution of MCP tube pore structure at an MCP pore diameter of 8 micrometer. This data validates the ICID concept for intensified photon counting readout. We also discuss correction techniques used in the removal of fixed pattern noise effects inherent in the centroiding algorithms used and present data which shows the local dynamic range of the device. Progress towards development of a true random access CID (RACID 810) is also discussed and astronomical data taken with the ICID detector system demonstrating the photon event time-tagging mode of the system is also presented.
2010-01-01
Background In resource-limited settings where nevirapine-containing regimen is the preferred regimen in women, data on severe adverse events (SAEs) according to CD4 cell count are limited. We estimated the incidence of SAEs according to CD4 cell count and identify their risk factors in nevirapine-treated women. Methods All HIV-infected women who initiated nevirapine-containing regimen in the MTCT-Plus operational program in Abidjan, Côte d'Ivoire, were eligible for this study. Laboratory and clinical (rash) SAEs were classified as grade 3 and 4. Cox models were used to identify factors associated with the occurrence of SAEs. Results From August 2003 to October 2006, 290 women initiated a nevirapine-containing regimen at a median CD4 cell count of 186 cells/mm3 (IQR 124-266). During a median follow-up on treatment of 25 months, the incidence of all SAEs was 19.5/100 patient-years. The 24-month probability of occurrence of hepatotoxicity or rash was not different between women with a CD4 cell count >250 cells/mm3 and women with a CD4 cell count ≤250 cells/mm3 (8.3% vs. 9.9%, Log-rank test: p = 0.75). In a multivariate proportional hazard model, neither CD4 cell count >250 cells/mm3 at treatment initiation nor initiation NVP-based regimen initiated during pregnancy were associated with the occurrence of SAEs. Conclusion CD4 cell count >250 cells/mm3 was not associated with a higher risk of severe hepatotoxicity and/or rash, as well as initiation of ART during pregnancy. Pharmacovogilance data as well as meta-analysis on women receiving NVP in these settings are needed for better information about NVP toxicity. PMID:20576111
Seo, Soo Hyun; Shin, Sue; Roh, Eun Youn; Song, Eun Young; Oh, Sohee; Kim, Byoung Jae; Yoon, Jong Hyun
2017-03-01
Maintaining the quality of cryopreserved cord blood is crucial. In this pilot study, we describe the results of the internal quality control program for a cord blood bank thus far. Donated cord blood units unsuitable for transplantation were selected for internal quality control once a month. One unit of cord blood, aliquoted into 21 capillaries, was cryopreserved and thawed annually to analyze the total nucleated cell count, CD34⁺ cell count, cell viability test, and colony-forming units assay. No significant differences in the variables (total nucleated cell count, cell viability, CD34⁺ cell count) were observed between samples cryopreserved for one and two years. Upon comparing the variables before cryopreservation and post thawing with the capillaries of one year of storage, cell viability and CD34⁺ cell counts decreased significantly. The use of cord blood samples in capillaries, which can be easily stored for a long period, was similar to the methods used for testing segments attached to the cord blood unit. The results of this study may be useful for determining the period during which the quality of cryopreserved cord blood units used for transplantation is maintained.
Seo, Soo Hyun; Shin, Sue; Roh, Eun Youn; Song, Eun Young; Oh, Sohee; Kim, Byoung Jae
2017-01-01
Background Maintaining the quality of cryopreserved cord blood is crucial. In this pilot study, we describe the results of the internal quality control program for a cord blood bank thus far. Methods Donated cord blood units unsuitable for transplantation were selected for internal quality control once a month. One unit of cord blood, aliquoted into 21 capillaries, was cryopreserved and thawed annually to analyze the total nucleated cell count, CD34+ cell count, cell viability test, and colony-forming units assay. Results No significant differences in the variables (total nucleated cell count, cell viability, CD34+ cell count) were observed between samples cryopreserved for one and two years. Upon comparing the variables before cryopreservation and post thawing with the capillaries of one year of storage, cell viability and CD34+ cell counts decreased significantly. The use of cord blood samples in capillaries, which can be easily stored for a long period, was similar to the methods used for testing segments attached to the cord blood unit. Conclusions The results of this study may be useful for determining the period during which the quality of cryopreserved cord blood units used for transplantation is maintained. PMID:28028998
Yang, Chaogang; Zhang, Nangang; Wang, Shuyi; Shi, Dongdong; Zhang, Chunxiao; Liu, Kan; Xiong, Bin
2018-05-23
Circulating tumor cells (CTCs) have great potential in both basic research and clinical application for the managements of cancer. However, the complicated fabrication processes and expensive materials of the existing CTCs isolation devices, to a large extent, limit their clinical translation and CTCs' clinical value. Therefore, it remains to be urgently needed to develop a new platform for achieving CTCs detection with low-cost, mass-producible but high performance. In the present study, we introduced a novel wedge-shaped microfluidic chip (named CTC-ΔChip) fabricated by two pieces of glass through wet etching and thermal bonding technique for CTCs isolation, which achieved CTCs enrichment by different size without cell surface expression markers and CTCs identification with three-color immunocytochemistry method (CK+/CD45-/Nucleus+). We validated the feasibility of CTC-ΔChip for detecting CTCs from different types of solid tumor. Furthermore, we applied the newly-developed platform to investigate the clinical significance of CTCs in gastric cancer (GC). Based on "label-free" characteristic, the capture efficiency of CTC-ΔChip can be as high as 93.7 ± 3.2% in DMEM and 91.0 ± 3.0% in whole blood sample under optimized conditions. Clinically, CTC-ΔChip exhibited the feasibility of detecting CTCs from different types of solid tumor, and it identified 7.30 ± 7.29 CTCs from 2 mL peripheral blood with a positive rate of 75% (30/40) in GC patients. Interestingly, we found that GC CTCs count was significantly correlated with multiple systemic inflammation indexes, including the lymphocyte count, platelet count, the level of neutrophil to lymphocyte ratio and platelet to lymphocyte ratio. In addition, we also found that both the positivity rate and CTCs count were significantly associated with multiple clinicopathology parameters. Our novel CTC-ΔChip shows high performance for detecting CTCs from less volume of blood samples of cancer patients and important clinical significance in GC. Owing to the advantages of low-cost and mass-producible, CTC-ΔChip holds great potential of clinical application for cancer therapeutic guidance and prognostic monitoring in the future.
NASA Astrophysics Data System (ADS)
Kassim, Muhammad Fuad bin; Norzali Haji Mohd, Mohd
2017-08-01
Technology is all about helping people, which created a new opportunity to take serious action in managing their health care. Moreover, Obesity continues to be a serious public health concern in the Malaysia and continuing to rise. Obesity has been a serious health concern among people. Nearly half of Malaysian people overweight. Most of dietary approach is not tracking and detecting the right calorie intake for weight loss, but currently used tools such as food diaries require users to manually record and track the food calories, making them difficult for daily use. We will be developing a new tool that counts the food intake bite by monitoring hand gesture and face jaw motion movement of caloric intake. The Bite count method showed a good significant that can lead to a successful weight loss by simply monitoring the bite taken during eating. The device used was Kinect Xbox One which used a depth camera to detect the motion on person hand and face during food intake. Previous studies showed that most of the method used to count bite device is worn type. The recent trend is now going towards non-wearable devices due to the difficulty when wearing devices and it has high false alarm ratio. The proposed system gets data from the Kinect that will be monitoring the hand and face gesture of the user while eating. Then, the gesture of hand and face data is sent to the microcontroller board to recognize and start counting bite taken by the user. The system recognizes the patterns of bite taken from user by following the algorithm of basic eating type either using hand or chopstick. This system can help people who are trying to follow a proper way to reduce overweight or eating disorders by monitoring their meal intake and controlling eating rate.
A sampling device for counting insect egg clusters and measuring vertical distribution of vegetation
Robert L. Talerico; Robert W., Jr. Wilson
1978-01-01
The use of a vertical sampling pole that delineates known volumes and position is illustrated and demonstrated for counting egg clusters of N. sertifer. The pole can also be used to estimate vertical and horizontal coverage, distribution or damage of vegetation or foliage.
Programmable random interval generator
NASA Technical Reports Server (NTRS)
Lindsey, R. S., Jr.
1973-01-01
Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.
Jose, S; Quinn, K; Dunn, D; Cox, A; Sabin, C; Fidler, S
2016-05-01
No randomized controlled trials have yet reported an individual patient benefit of initiating combination antiretroviral therapy (cART) at CD4 counts > 350 cells/μL. It is hypothesized that earlier initiation of cART in asymptomatic and otherwise healthy individuals may lead to poorer adherence and subsequently higher rates of resistance development. In a large cohort of HIV-positive individuals, we investigated the emergence of new resistance mutations upon virological treatment failure according to the CD4 count at the initiation of cART. Of 7918 included individuals, 6514 (82.3%), 996 (12.6%) and 408 (5.2%) started cART with a CD4 count ≤ 350, 351-499 and ≥ 500 cells/μL, respectively. Virological rebound occurred while on cART in 488 (7.5%), 46 (4.6%) and 30 (7.4%) with a baseline CD4 count ≤ 350, 351-499 and ≥ 500 cells/μL, respectively. Only four (13.0%) individuals with a baseline CD4 count > 350 cells/μL in receipt of a resistance test at viral load rebound were found to have developed new resistance mutations. This compared to 107 (41.2%) of those with virological failure who had initiated cART with a CD4 count < 350 cells/μL. We found no evidence of increased rates of resistance development when cART was initiated at CD4 counts above 350 cells/μL. © 2015 The Authors. HIV Medicine published by John Wiley & Sons Ltd on behalf of British HIV Association.
NASA Astrophysics Data System (ADS)
DiFilippo, Frank P.; Patel, Sagar
2009-06-01
A multi-pinhole collimation device for small animal single photon emission computed tomography (SPECT) uses the gamma camera detectors of a standard clinical SPECT scanner. The collimator and animal bed move independently of the detectors, and therefore their motions must be synchronized. One approach is manual triggering of the SPECT acquisition simultaneously with a programmed motion sequence for the device. However, some data blurring and loss of image quality result, and true electronic synchronization is preferred. An off-the-shelf digital gyroscope with integrated Bluetooth interface provides a wireless solution to device synchronization. The sensor attaches to the SPECT gantry and reports its rotational speed to a notebook computer controlling the device. Software processes the rotation data in real-time, averaging the signal and issuing triggers while compensating for baseline drift. Motion commands are sent to the collimation device with minimal delay, within approximately 0.5 second of the start of SPECT gantry rotation. Test scans of a point source demonstrate an increase in true counts and a reduction in background counts compared to manual synchronization. The wireless rotation sensor provides robust synchronization of the collimation device with the clinical SPECT scanner and enhances image quality.
Barnes, Neil; Ishii, Takeo; Hizawa, Nobuyuki; Midwinter, Dawn; James, Mark; Hilton, Emma; Jones, Paul W
2018-01-01
Blood eosinophil measurements may help to guide physicians on the use of inhaled corticosteroids (ICS) for patients with chronic obstructive pulmonary disease (COPD). Emerging data suggest that COPD patients with higher blood eosinophil counts may be at higher risk of exacerbations and more likely to benefit from combined ICS/long-acting beta 2 -agonist (LABA) treatment than therapy with a LABA alone. This analysis describes the distribution of blood eosinophil count at baseline in Japanese COPD patients in comparison with non-Japanese COPD patients. A post hoc analysis of eosinophil distribution by percentage and absolute cell count was performed across 12 Phase II-IV COPD clinical studies (seven Japanese studies [N=848 available absolute eosinophil counts] and five global studies [N=5,397 available eosinophil counts] that included 246 Japanese patients resident in Japan with available counts). Blood eosinophil distributions were assessed at baseline, before blinded treatment assignment. Among Japanese patients, the median (interquartile range) absolute eosinophil count was 170 cells/mm 3 (100-280 cells/mm 3 ). Overall, 612/1,094 Japanese patients (56%) had an absolute eosinophil count ≥150 cells/mm 3 and 902/1,304 Japanese patients (69%) had a percentage eosinophil ≥2%. Among non-Japanese patients, these values were 160 (100-250) cells/mm 3 , 2,842/5,151 patients (55%), and 2,937/5,155 patients (57%), respectively. The eosinophil distribution among Japanese patients was similar to that among non-Japanese patients. Within multi-country studies with similar inclusion criteria, the eosinophil count was numerically lower in Japanese compared with non-Japanese patients (median 120 vs 160 cells/mm 3 ). The eosinophil distribution in Japanese patients seems comparable to that of non-Japanese patients; although within multi-country studies, there was a slightly lower median eosinophil count for Japanese patients compared with non-Japanese patients. These findings suggest that blood eosinophil data from global studies are of relevance in Japan.
NASA Astrophysics Data System (ADS)
Warger, William C., II; Newmark, Judith A.; Zhao, Bing; Warner, Carol M.; DiMarzio, Charles A.
2006-02-01
Present imaging techniques used in in vitro fertilization (IVF) clinics are unable to produce accurate cell counts in developing embryos past the eight-cell stage. We have developed a method that has produced accurate cell counts in live mouse embryos ranging from 13-25 cells by combining Differential Interference Contrast (DIC) and Optical Quadrature Microscopy. Optical Quadrature Microscopy is an interferometric imaging modality that measures the amplitude and phase of the signal beam that travels through the embryo. The phase is transformed into an image of optical path length difference, which is used to determine the maximum optical path length deviation of a single cell. DIC microscopy gives distinct cell boundaries for cells within the focal plane when other cells do not lie in the path to the objective. Fitting an ellipse to the boundary of a single cell in the DIC image and combining it with the maximum optical path length deviation of a single cell creates an ellipsoidal model cell of optical path length deviation. Subtracting the model cell from the Optical Quadrature image will either show the optical path length deviation of the culture medium or reveal another cell underneath. Once all the boundaries are used in the DIC image, the subtracted Optical Quadrature image is analyzed to determine the cell boundaries of the remaining cells. The final cell count is produced when no more cells can be subtracted. We have produced exact cell counts on 5 samples, which have been validated by Epi-Fluorescence images of Hoechst stained nuclei.
Enhancing the Linear Dynamic Range in Multi-Channel Single Photon Detector beyond 7OD
Gudkov, Dmytro; Gudkov, George; Gorbovitski, Boris; Gorfinkel, Vera
2015-01-01
We present design, implementation, and characterization of a single photon detector based on 32-channel PMT sensor [model H7260-20, Hamamatsu]. The developed high speed electronics enables the photon counting with linear dynamic range (LDR) up to 108count/s per detector's channel. The experimental characterization and Monte-Carlo simulations showed that in the single photon counting mode the LDR of the PMT sensor is limited by (i) “photon” pulse width (current pulse) of 900ps and (ii) substantial decrease of amplitudes of current pulses for count rates exceeding 108 count/s. The multi-channel architecture of the detector and the developed firm/software allow further expansion of the dynamic range of the device by 32-fold by using appropriate beam shaping. The developed single photon counting detector was tested for the detection of fluorescence labeled microbeads in capillary flow. PMID:27087788
Relationship of milking rate to somatic cell count.
Brown, C A; Rischette, S J; Schultz, L H
1986-03-01
Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.
Low Blood Cell Counts: Side Effect of Cancer Treatment
... and, in particular, a low level of neutrophils (neutropenia), a type of white blood cell that fights ... Cancer Institute, 2011 Low white blood cell count Fever higher than 100.5 F (38 C) Chills ...
Performance evaluation of Abbott CELL-DYN Ruby for routine use.
Lehto, T; Hedberg, P
2008-10-01
CELL-DYN Ruby is a new automated hematology analyzer suitable for routine use in small laboratories and as a back-up or emergency analyzer in medium- to high-volume laboratories. The analyzer was evaluated by comparing the results from the CELL-DYN((R)) Ruby with the results obtained from CELL-DYN Sapphire . Precision, linearity, and carryover between patient samples were also assessed. Precision was good at all levels for the routine cell blood count (CBC) parameters, CV% being
Common sense behavior modification: a guide for practitioners.
Horwitz, Debra F; Pike, Amy L
2014-05-01
Behavior problems are often given as a reason for pet relinquishment to shelters. When presented with any behavior problem, veterinarians should perform a thorough physical examination (including neurologic and orthopedic examination) and a minimum database, including a complete blood cell count, chemistry panel, and total T4 and free T4 by equilibrium dialysis if values are low to rule out any medical contributions. Veterinarians should be a source of information regarding management, safety, and basic behavior modification for common behavior problems. Additionally, various control devices offer pet owners the ability to better manage their pets in difficult situations. Copyright © 2014 Elsevier Inc. All rights reserved.
Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Kawase, Tomoyuki
2016-11-01
Platelet-rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers ( N = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84-fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79- and 5.51-fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose-dependent stimulation of periosteal cell proliferation in vitro.
Nishiyama, Kazuhiko; Okudera, Toshimitsu; Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Masashi; Masuki, Hideo; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh
2016-01-01
Abstract Platelet‐rich plasma (PRP) is widely used in regenerative medicine because of its high concentrations of various growth factors and platelets. However, the distribution of blood cell components has not been investigated in either PRP or other PRP derivatives. In this study, we focused on plasma rich in growth factors (PRGF), a PRP derivative, and analyzed the distributions of platelets and white blood cells (WBCs). Peripheral blood samples were collected from healthy volunteers (N = 14) and centrifuged to prepare PRGF and PRP. Blood cells were counted using an automated hematology analyzer. The effects of PRP and PRGF preparations on cell proliferation were determined using human periosteal cells. In the PRGF preparations, both red blood cells and WBCs were almost completely eliminated, and platelets were concentrated by 2.84‐fold, whereas in the PRP preparations, both platelets and WBCs were similarly concentrated by 8.79‐ and 5.51‐fold, respectively. Platelet counts in the PRGF preparations were positively correlated with platelet counts in the whole blood samples, while the platelet concentration rate was negatively correlated with red blood cell counts in the whole blood samples. In contrast, platelet counts and concentration rates in the PRP preparations were significantly influenced by WBC counts in whole blood samples. The PRP preparations, but not the PRGF preparations, significantly suppressed cell growth at higher doses in vitro. Therefore, these results suggest that PRGF preparations can clearly be distinguished from PRP preparations by both inclusion of WBCs and dose‐dependent stimulation of periosteal cell proliferation in vitro. PMID:29744155
Nasi, Milena; De Biasi, Sara; Bianchini, Elena; Gibellini, Lara; Pinti, Marcello; Scacchetti, Tiziana; Trenti, Tommaso; Borghi, Vanni; Mussini, Cristina; Cossarizza, Andrea
2015-01-01
Background An accurate and affordable CD4+ T cells count is an essential tool in the fight against HIV/AIDS. Flow cytometry (FCM) is the “gold standard” for counting such cells, but this technique is expensive and requires sophisticated equipment, temperature-sensitive monoclonal antibodies (mAbs) and trained personnel. The lack of access to technical support and quality assurance programs thus limits the use of FCM in resource-constrained countries. We have tested the accuracy, the precision and the carry-over contamination of Partec CyFlow MiniPOC, a portable and economically affordable flow cytometer designed for CD4+ count and percentage, used along with the “CD4% Count Kit-Dry”. Materials and Methods Venous blood from 59 adult HIV+ patients (age: 25–58 years; 43 males and 16 females) was collected and stained with the “MiniPOC CD4% Count Kit-Dry”. CD4+ count and percentage were then determined in triplicate by the CyFlow MiniPOC. In parallel, CD4 count was performed using mAbs and a CyFlow Counter, or by a dual platform system (from Beckman Coulter) based upon Cytomic FC500 (“Cytostat tetrachrome kit” for mAbs) and Coulter HmX Hematology Analyzer (for absolute cell count). Results The accuracy of CyFlow MiniPOC against Cytomic FC500 showed a correlation coefficient (CC) of 0.98 and 0.97 for CD4+ count and percentage, respectively. The accuracy of CyFlow MiniPOC against CyFlow Counter showed a CC of 0.99 and 0.99 for CD4 T cell count and percentage, respectively. CyFlow MiniPOC showed an excellent repeatability: CD4+ cell count and percentage were analyzed on two instruments, with an intra-assay precision below ±5% deviation. Finally, there was no carry-over contamination for samples at all CD4 values, regardless of their position in the sequence of analysis. Conclusion The cost-effective CyFlow MiniPOC produces rapid, reliable and accurate results that are fully comparable with those from highly expensive dual platform systems. PMID:25622041
The evolving role of CD4 cell counts in HIV care.
Ford, Nathan; Meintjes, Graeme; Vitoria, Marco; Greene, Greg; Chiller, Tom
2017-03-01
The role of the CD4 cell count in the management of people living with HIV is once again changing, most notably with a shift away from using CD4 assays to decide when to start antiretroviral therapy (ART). This article reflects on the past, current and future role of CD4 cell count testing in HIV programmes, and the implications for clinicians, programme managers and diagnostics manufacturers. Following the results of recent randomized trials demonstrating the clinical and public health benefits of starting ART as soon as possible after HIV diagnosis is confirmed, CD4 cell count is no longer recommended as a way to decide when to initiate ART. For patients stable on ART, CD4 cell counts are no longer needed to monitor the response to treatment where HIV viral load testing is available. Nevertheless CD4 remains the best measurement of a patient's immune and clinical status, the risk of opportunistic infections, and supports diagnostic decision-making, particularly for patients with advanced HIV disease. As countries revise guidelines to provide ART to all people living with HIV and continue to scale up access to viral load, strategic choices will need to be made regarding future investments in CD4 cell count and the appropriate use for clinical disease management.
Bhattar, Sonali; Mehra, Bhanu; Bhalla, Preena; Rawat, Deepti
2016-11-01
Antiretroviral Therapy (ART) has changed the outlook of Human Immune-deficiency Virus (HIV)/Acquired Immuno Deficiency Syndrome (AIDS) patients worldwide. To analyse the trends in baseline CD4+ T cell counts and ART requirements in newly diagnosed HIV seropositive individuals in a Tertiary care hospital of Northern India. Out of 1263 HIV seropositive clients identified from January 2012 to June 2014, the baseline CD4+ T cell counts of only those 470 clients were analysed, who registered at the linked ART centre. The mean baseline CD4+ count of the study group was 249.77±216.0cells/mm 3 and that of male and female were 300.31±240.47cells/mm 3 and 232.38±204.25cells/mm 3 respectively. A total of 259 of 334 (77.54%) HIV reactive males, 83 of 130 (63.85%) HIV reactive females and overall 348 of 470 (74.04%) required antiretroviral treatment on enrolment. In the present study, about three-fourth of newly diagnosed HIV positive Indian patients required initiation of ART at registration. The relatively low baseline CD4+ T cell counts in this population highlights the need for timely baseline CD4+ counts testing of HIV positive patients and the urgency of initiating treatment in HIV reactive individuals in Indian health care settings.
Lisle, John T.; Hamilton, Martin A.; Willse, Alan R.; McFeters, Gordon A.
2004-01-01
Total direct counts of bacterial abundance are central in assessing the biomass and bacteriological quality of water in ecological and industrial applications. Several factors have been identified that contribute to the variability in bacterial abundance counts when using fluorescent microscopy, the most significant of which is retaining an adequate number of cells per filter to ensure an acceptable level of statistical confidence in the resulting data. Previous studies that have assessed the components of total-direct-count methods that contribute to this variance have attempted to maintain a bacterial cell abundance value per filter of approximately 106 cells filter-1. In this study we have established the lower limit for the number of bacterial cells per filter at which the statistical reliability of the abundance estimate is no longer acceptable. Our results indicate that when the numbers of bacterial cells per filter were progressively reduced below 105, the microscopic methods increasingly overestimated the true bacterial abundance (range, 15.0 to 99.3%). The solid-phase cytometer only slightly overestimated the true bacterial abundances and was more consistent over the same range of bacterial abundances per filter (range, 8.9 to 12.5%). The solid-phase cytometer method for conducting total direct counts of bacteria was less biased and performed significantly better than any of the microscope methods. It was also found that microscopic count data from counting 5 fields on three separate filters were statistically equivalent to data from counting 20 fields on a single filter.
Choi, Woo June; Pepple, Kathryn L; Wang, Ruikang K
2018-05-24
In preclinical vision research, cell grading in small animal models is essential for the quantitative evaluation of intraocular inflammation. Here, we present a new and practical optical coherence tomography (OCT) image analysis method for the automated detection and counting of aqueous cells in the anterior chamber (AC) of a rodent model of uveitis. Anterior segment OCT (AS-OCT) images are acquired with a 100kHz swept-source OCT (SS-OCT) system. The proposed method consists of two steps. In the first step, we first despeckle and binarize each OCT image. After removing AS structures in the binary image, we then apply area thresholding to isolate cell-like objects. Potential cell candidates are selected based on their best fit to roundness. The second step performs the cell counting within the whole AC, in which additional cell tracking analysis is conducted on the successive OCT images to eliminate redundancy in cell counting. Finally, 3-D cell grading using the proposed method is demonstrated in longitudinal OCT imaging of a mouse model of anterior uveitis in vivo. Rendering of anterior segment (orange) of mouse eye and automatically counted anterior chamber cells (green). Inset is a top view of the rendering, showing the cell distribution across the anterior chamber. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Lahoti, Sonal; Rao, Kavita; Umadevi, H S; Mishra, Lakshmi
2017-01-01
As the search for reliable clinical indicators for management of human immunodeficiency virus/AIDS continues, mucocutaneous manifestations of HIV are considered among key clinical indicators for prediction of underlying degree of immunosuppression, systemic opportunistic infections, and disease progression. (1) To study the prevalence of mucocutaneous manifestations in HIV-seropositive patients attending the ART center of our hospital (2) To correlate mucocutaneous manifestations with CD4 cell counts. A total of 200 HIV-seropositive patients of adult age group visiting our hospital were included in the study. Information on demographics such as age, sex, transmission route, socioeconomic status, educational status, CD4 counts, and mucocutaneous findings was collected through interview administered survey and case records followed by oral and cutaneous examination. Mean CD4 cell count of asymptomatic HIV/AIDS patients was 580.96 cells/mm3. In comparison with the CD4 cell count of asymptomatic HIV-positive patients, (mean 580.96 cells/mm3) CD4 cell count of HIV-positive patients with various mucocutaneous manifestations (mean 409.65 cells/mm3) was correlated using student t-test and was statistically significant (P = 0.017). This study revealed maximum mucocutaneous lesions in the CD4 count range of 200-500. Nail changes accounted for the most common cutaneous manifestation with 53%, and pigmentation accounted for the most common oral manifestation with 39%. Mucocutaneous manifestations can arouse one to suspect the diagnosis of HIV infection in an otherwise healthy unwary patient. They can serve as a dependable marker of HIV disease.
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
The Effects of Gamma and Proton Radiation Exposure on Hematopoietic Cell Counts in the Ferret Model
Sanzari, Jenine K.; Wan, X. Steven; Krigsfeld, Gabriel S.; Wroe, Andrew J.; Gridley, Daila S.; Kennedy, Ann R.
2014-01-01
Exposure to total-body radiation induces hematological changes, which can detriment one's immune response to wounds and infection. Here, the decreases in blood cell counts after acute radiation doses of γ-ray or proton radiation exposure, at the doses and dose-rates expected during a solar particle event (SPE), are reported in the ferret model system. Following the exposure to γ-ray or proton radiation, the ferret peripheral total white blood cell (WBC) and lymphocyte counts decreased whereas neutrophil count increased within 3 hours. At 48 hours after irradiation, the WBC, neutrophil, and lymphocyte counts decreased in a dose-dependent manner but were not significantly affected by the radiation type (γ-rays verses protons) or dose rate (0.5 Gy/minute verses 0.5 Gy/hour). The loss of these blood cells could accompany and contribute to the physiological symptoms of the acute radiation syndrome (ARS). PMID:25356435
Effects of incarceration on HIV-infected individuals.
Griffin, M M; Ryan, J G; Briscoe, V S; Shadle, K M
1996-10-01
Human immunodeficiency virus (HIV) infection is a critical problem among the incarcerated population, with rates as high as 17% being reported for prison systems in New York. The literature suggests that stressful living conditions and inherent defects in the immune system associated with HIV infection make prison populations more susceptible to a disproportionate decrease in their CD4 counts. To determine the effects of incarceration on HIV-infected individuals, the charts of 800 inmates were reviewed. Baseline (draw 1), 2- to 5-month (draw 2), and 6- to 12-month (draw 3) CD4 cell counts were obtained. Mean cell counts were calculated, and paired t-tests were used to identify differences. The group receiving antiretrovirals throughout showed no difference in mean CD4 cell count between draws 1 and 2 or between draws 1 and 3. The group not receiving HIV medications did not show a significant difference in CD4 cell counts between draws 1 and 2, but did show a significant difference between draws 1 and 3. For this group, the rate of decline in CD4 cells was greater than among an outpatient setting. The subsample of subjects initiating therapy prior to the second blood draw showed a significant increase in mean CD4 cell counts at draw 1 versus draw 2, but did not show a significant change when comparing draw 1 to draw 3. When examining subjects based on their antiviral status, the mean CD4 cell count at each of the draws was statistically associated with subjects' antiviral status. We conclude that incarceration causes a more rapid decrease in CD4 cells compared with an outpatient population, causing clinical significance on the normal course of HIV disease.
Association Between HIV-1 RNA Level and CD4 Cell Count Among Untreated HIV-Infected Individuals
Lima, Viviane D.; Fink, Valeria; Yip, Benita; Hogg, Robert S.; Harrigan, P. Richard
2009-01-01
Objectives. We examined the significance of plasma HIV-1 RNA levels (or viral load alone) in predicting CD4 cell decline in untreated HIV-infected individuals. Methods. Data were obtained from the British Columbia Centre for Excellence in HIV/AIDS. Participants included all residents who ever had a viral load determination in the province and who had never taken antiretroviral drugs (N = 890). We analyzed a total of 2074 viral load measurements and 2332 CD4 cell counts. Linear mixed-effects models were used to predict CD4 cell decline over time. Results. Longitudinal viral load was strongly associated with CD4 cell decline over time; an average of 1 log10 increase in viral load was associated with a 55-cell/mm3 decrease in CD4 cell count. Conclusions. Our results support the combined use of CD4 cell count and viral load as prognostic markers in HIV-infected individuals before the introduction of antiretroviral therapy. PMID:19218172
Chen, Shu-Huey; Yang, Shang-Hsien; Chu, Sung-Chao; Su, Yu-Chieh; Chang, Chu-Yu; Chiu, Ya-Wen; Kao, Ruey-Ho; Li, Dian-Kun; Yang, Kuo-Liang; Wang, Tso-Fu
2011-05-01
Granulocyte colony-stimulating factor (G-CSF) is now widely used for stem cell mobilization. We evaluated the role of post-G-CSF white blood cell (WBC) counts and donor factors in predicting adverse events and yields associated with mobilization. WBC counts were determined at baseline, after the third and the fifth dose of G-CSF in 476 healthy donors. Donors with WBC ≥ 50 × 10(3)/μL post the third dose of G-CSF experienced more fatigue, myalgia/arthralgia, and chills, but final post-G-CSF CD34(+) cell counts were similar. Although the final CD34(+) cell count was higher in donors with WBC ≥ 50 × 10(3)/μL post the fifth G-CSF, the incidence of side effects was similar. Females more frequently experienced headache, nausea/anorexia, vomiting, fever, and lower final CD34(+) cell count than did males. Donors with body mass index (BMI) ≥ 25 showed higher incidences of sweat and insomnia as well as higher final CD34(+) cell counts. Donor receiving G-CSF ≥ 10 μg/kg tended to experience bone pain, headache and chills more frequently. Multivariate analysis indicated that female gender is an independent factor predictive of the occurrence of most side effects, except for ECOG > 1 and chills. Higher BMI was also an independent predictor for fatigue, myalgia/arthralgia, and sweat. Higher G-CSF dose was associated with bone pain, while the WBC count post the third G-CSF was associated with fatigue only. In addition, one donor in the study period did not complete the mobilization due to suspected anaphylactoid reaction. Observation for 1 h after the first injection of G-CSF is required to prevent complications from unpredictable side effects.
Skinner, John P.; Tuomi, Pam A.; Mellish, Jo-Ann E.
2015-01-01
The Steller sea lion, Eumetopias jubatus, has experienced regionally divergent population trends over recent decades. One potential mechanism for this disparity is that local factors cause reduced health and, therefore, reduced survival of individuals. The use of blood parameters to assess sea lion health may help to identify whether malnutrition, disease and stress are important drivers of current trends, but such assessments require species-specific knowledge of how parameters respond to various health challenges. We used principal components analysis to identify which key blood parameters (principal analytes) best described changes in health for temporarily captive juvenile Steller sea lions in known conditions. Generalized additive mixed models were used to estimate the changes in principal analytes with food intake, time in captivity and acute trauma associated with hot-iron branding and transmitter implant surgery. Of the 17 blood parameters examined, physiological changes for juvenile sea lions were best described using the following six principal analytes: red blood cell counts, white blood cell counts, globulin, platelets, glucose and total bilirubin. The white blood cell counts and total bilirubin declined over time in captivity, whereas globulin increased. Elevated red blood cell counts, white blood cell counts and total bilirubin and reduced globulin values were associated with lower food intake. After branding, white blood cell counts were elevated for the first 30 days, while globulin and platelets were elevated for the first 15 days only. After implant surgery, red blood cell counts and globulin remained elevated for 30 days, while white blood cell counts remained elevated during the first 15 days only. Glucose was unassociated with the factors we studied. These results were used to provide expected ranges for principal analytes at different levels of food intake and in response to the physical challenges of branding and implant surgery. These results provide a more detailed reference for future evaluations of health-related assessments. PMID:27293693
Yarnell, J W; Baker, I A; Sweetnam, P M; Bainton, D; O'Brien, J R; Whitehead, P J; Elwood, P C
1991-03-01
Recent studies have suggested that hemostatic factors and white blood cell count are predictive of ischemic heart disease (IHD). The relations of fibrinogen, viscosity, and white blood cell count to the incidence of IHD in the Caerphilly and Speedwell prospective studies are described. The two studies have a common core protocol and are based on a combined cohort of 4,860 middle-aged men from the general population. The first follow-up was at a nearly constant interval of 5.1 years in Caerphilly and 3.2 years in Speedwell; 251 major IHD events had occurred. Age-adjusted relative odds of IHD for men in the top 20% of the distribution compared with the bottom 20% were 4.1 (95% confidence interval, 2.6-6.5) for fibrinogen, 4.5 (95% confidence interval, 2.8-7.4) for viscosity, and 3.2 (95% confidence interval, 2.0-4.9) for white blood cell count. Associations with IHD were similar in men who had never smoked, exsmokers, and current smokers, and the results suggest that at least part of the effect of smoking on IHD is mediated through fibrinogen, viscosity, and white blood cell count. Multivariate analysis shows that white blood cell count is an independent risk factor for IHD as is either fibrinogen or viscosity, or possibly both. Jointly, these three variables significantly improve the fit of a logistic regression model containing all the main conventional risk factors. Further, a model including age, smoking habits, fibrinogen, viscosity, and white blood cell count predicts IHD as well as one in which the three hemostatic/rheological variables are replaced by total cholesterol, diastolic pressure, and body mass index. Jointly, fibrinogen, viscosity, and white blood cell count are important risk factors for IHD.
Mayhew, Terry M; Mühlfeld, Christian; Vanhecke, Dimitri; Ochs, Matthias
2009-04-01
Detecting, localising and counting ultrasmall particles and nanoparticles in sub- and supra-cellular compartments are of considerable current interest in basic and applied research in biomedicine, bioscience and environmental science. For particles with sufficient contrast (e.g. colloidal gold, ferritin, heavy metal-based nanoparticles), visualization requires the high resolutions achievable by transmission electron microscopy (TEM). Moreover, if particles can be counted, their spatial distributions can be subjected to statistical evaluation. Whatever the level of structural organisation, particle distributions can be compared between different compartments within a given structure (cell, tissue and organ) or between different sets of structures (in, say, control and experimental groups). Here, a portfolio of stereology-based methods for drawing such comparisons is presented. We recognise two main scenarios: (1) section surface localisation, in which particles, exemplified by antibody-conjugated colloidal gold particles or quantum dots, are distributed at the section surface during post-embedding immunolabelling, and (2) section volume localisation (or full section penetration), in which particles are contained within the cell or tissue prior to TEM fixation and embedding procedures. Whatever the study aim or hypothesis, the methods for quantifying particles rely on the same basic principles: (i) unbiased selection of specimens by multistage random sampling, (ii) unbiased estimation of particle number and compartment size using stereological test probes (points, lines, areas and volumes), and (iii) statistical testing of an appropriate null hypothesis. To compare different groups of cells or organs, a simple and efficient approach is to compare the observed distributions of raw particle counts by a combined contingency table and chi-squared analysis. Compartmental chi-squared values making substantial contributions to total chi-squared values help identify where the main differences between distributions reside. Distributions between compartments in, say, a given cell type, can be compared using a relative labelling index (RLI) or relative deposition index (RDI) combined with a chi-squared analysis to test whether or not particles preferentially locate in certain compartments. This approach is ideally suited to analysing particles located in volume-occupying compartments (organelles or tissue spaces) or surface-occupying compartments (membranes) and expected distributions can be generated by the stereological devices of point, intersection and particle counting. Labelling efficiencies (number of gold particles per antigen molecule) in immunocytochemical studies can be determined if suitable calibration methods (e.g. biochemical assays of golds per membrane surface or per cell) are available. In addition to relative quantification for between-group and between-compartment comparisons, stereological methods also permit absolute quantification, e.g. total volumes, surfaces and numbers of structures per cell. Here, the utility, limitations and recent applications of these methods are reviewed.
THE DISPERSION OF HERBACEOUS PLANT POLLEN IN ITO CITY, SHIZUOKA.
Fujii, Mayumi; Makiyama, Kiyoshi; Okazaki, Kenji; Hisamatsu, Kenichi
2016-08-01
Airborne pollen was examined in Ito City, Shizuoka for the purpose of treatment and prophylaxis pollen allergies because the patients with pollen allergy to herbaceous plants have recently increased. Setting up a Durham's sampler, we measured airborne pollen identified and classified: Poaceae, Polygonaceae, Amaranthaceae, Urticaceae, Cannabaceae, Ambrosia and Artemisia indica.We studied whether each airborne pollen count has something to do with weather condition (2004-2015). Average total airborne Poaceae pollen count and standard deviation from January to June was 19.4±5.5 cells/cm(2), average total airborne Polygonaceae pollen count and standard deviation from April to September was 11.6±13.4 cells/cm(2). Airborne Poaceae, Amaranthaceae, Cannabaceae, Uriticaceae. Ambrosia and Artamisia indica pollen count from July to Deccember in order: 34.0±15.5 cells/cm(2), 1.3±1.1 cells/cm(2), 8.7±6.4cells/cm(2), 4.9±6.4 cells/cm(2), 10.5±7.8 cells/cm(2), and 13.6±16.3 cells/cm(2).Cannabaceae admitted that its airborne pollen count has negative correlation to the rainfall.Artemisia indica admitted that its airborne pollen count has negative correlation to the average temperature. Herbaceous plants pollen doesn't cause allergies because it is much less than tree pollen in ItoCity.It is thought that the diversity of the plants keep the people from having a serious allergy to pollen with awarm weather in this area.
Cserni, Tamas; O' Donnel, Annemarie; Paran, Sri; Puri, Prem
2009-03-01
Nicotinamide adenine dinucleotide phosphate-diaphorase (NADPH-d) staining can be used in the enteric nervous system to determine nitrergic neuronal counts, critical in motility disorders such as intestinal neuronal dysplasia and hypoganglionosis. The reported incubation periods of specimens with NADPH-d staining solution has varied from 2 to 24 h. The aim of this study is to investigate the impact of the incubation period on the overall NADPH-d positive cell counts in porcine rectal submucosal plexus. The submucosal plexus of rectal specimens from 12-week-old pigs (n = 5) were studied. Conventional frozen sections were used to identify nitrergic neurons while whole-mount preparations were used to quantify the effect of prolonged duration of incubation on positively identified ganglion cells with NADPH-d histochemistry. The same submucosal ganglia on the conventional sections, and a minimum of 12 ganglia per whole-mount preparation specimen were photographed sequentially at 2, 6, and 24 h and used to count the number of nitrergic cells per ganglion. The same staining solution was used throughout the experiment. Results were analysed using a one-way ANOVA test. Prolonged incubation with the staining solution revealed new NADPH-d positive cells in the ganglia on the conventional sections. The total number of neurons counted in the 12 adjacent ganglia in the whole-mount specimens was 180 +/- 55, the mean neuronal cell per ganglion was 15 +/- 8 after 2 h of incubation. This increased to 357 +/- 17, and to 29 +/- 12 after 6 h (p < 0.05). A further increase was observed of 515 +/- 19 and 43 +/- 17 after 24 h (p < 0.05). When the photomicrographs were retrospectively analysed, not even the outline of the neuronal cells that stained with prolonged incubation was evident at the earlier time points. NADPH-d positive cell counts increase in proportion to the duration of incubation in NADPH-d histochemistry. Comparative studies attempting to quantify nitrergic cell counts in dysmotility disorders must take into account the variability in NADPH-d positive cell count associated with prolonged incubation in NADPH-d histochemistry.
Baveewo, Steven; Ssali, Francis; Karamagi, Charles; Kalyango, Joan N; Hahn, Judith A; Ekoru, Kenneth; Mugyenyi, Peter; Katabira, Elly
2011-05-12
The WHO clinical guidelines for HIV/AIDS are widely used in resource limited settings to represent the gold standard of CD4 counts for antiviral therapy initiation. The utility of the WHO-defined stage 1 and 2 clinical factors used in WHO HIV/AIDS clinical staging in predicting low CD4 cell count has not been established in Uganda. Although the WHO staging has shown low sensitivity for predicting CD4<200 cells/mm(3), it has not been evaluated at for CD4 cut-offs of <250 cells/mm(3) or <350 cells/mm(3). To validate the World Health Organisation HIV/AIDS clinical staging in predicting initiation of antiretroviral therapy in a low-resource setting and to determine the clinical predictors of low CD4 cell count in Uganda. Data was collected on 395 participants from the Joint Clinical Research Centre, of whom 242 (61.3%) were classified as in stages 1 and 2 and 262 (68%) were females. Participants had a mean age of 36.8 years (SD 8.5). We found a significant inverse correlation between the CD4 lymphocyte count and WHO clinical stages. The sensitivity the WHO clinical staging at CD4 cell count of 250 cells/mm(3) and 350 cells/mm(3) was 53.5% and 49.1% respectively. Angular cheilitis, papular pruritic eruptions and recurrent upper respiratory tract infections were found to be significant predictors of low CD4 cell count among participants in WHO stage 1 and 2. The WHO HIV/AIDS clinical staging guidelines have a low sensitivity and about half of the participants in stages 1 and 2 would be eligible for ART initiation if they had been tested for CD4 count. Angular cheilitis and papular pruritic eruptions and recurrent upper respiratory tract infections may be used, in addition to the WHO staging, to improve sensitivity in the interim, as access to CD4 machines increases in Uganda.
Heijnen, Ingmar A F M; Barnett, David; Arroz, Maria J; Barry, Simon M; Bonneville, Marc; Brando, Bruno; D'hautcourt, Jean-Luc; Kern, Florian; Tötterman, Thomas H; Marijt, Erik W A; Bossy, David; Preijers, Frank W M B; Rothe, Gregor; Gratama, Jan W
2004-11-01
HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/microl were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method. Between-site coefficients of variation of less than 10% (absolute CD8(+) T-cell counts) and approximately 30% (percentage and absolute numbers of CMV-specific CD8(+) T cells) were achieved. Within-site coefficients of variation were approximately 5% (absolute CD8(+) T-cell counts), approximately 9% (percentage CMV-specific CD8(+) T cells), and approximately 17% (absolute CMV-specific CD8(+) T-cell counts). The degree of variation tended to correlate inversely with the proportion of CMV-specific CD8(+) T-cell subsets. The single-platform MHC tetramer-based method for antigen-specific CD8(+) T-cell counting has been evaluated by a European group of laboratories and can be considered a reproducible assay for routine enumeration of antigen-specific CD8(+) T cells. (c) 2004 Wiley-Liss, Inc.
Developments in label-free microfluidic methods for single-cell analysis and sorting.
Carey, Thomas R; Cotner, Kristen L; Li, Brian; Sohn, Lydia L
2018-04-24
Advancements in microfluidic technologies have led to the development of many new tools for both the characterization and sorting of single cells without the need for exogenous labels. Label-free microfluidics reduce the preparation time, reagents needed, and cost of conventional methods based on fluorescent or magnetic labels. Furthermore, these devices enable analysis of cell properties such as mechanical phenotype and dielectric parameters that cannot be characterized with traditional labels. Some of the most promising technologies for current and future development toward label-free, single-cell analysis and sorting include electronic sensors such as Coulter counters and electrical impedance cytometry; deformation analysis using optical traps and deformation cytometry; hydrodynamic sorting such as deterministic lateral displacement, inertial focusing, and microvortex trapping; and acoustic sorting using traveling or standing surface acoustic waves. These label-free microfluidic methods have been used to screen, sort, and analyze cells for a wide range of biomedical and clinical applications, including cell cycle monitoring, rapid complete blood counts, cancer diagnosis, metastatic progression monitoring, HIV and parasite detection, circulating tumor cell isolation, and point-of-care diagnostics. Because of the versatility of label-free methods for characterization and sorting, the low-cost nature of microfluidics, and the rapid prototyping capabilities of modern microfabrication, we expect this class of technology to continue to be an area of high research interest going forward. New developments in this field will contribute to the ongoing paradigm shift in cell analysis and sorting technologies toward label-free microfluidic devices, enabling new capabilities in biomedical research tools as well as clinical diagnostics. This article is categorized under: Diagnostic Tools > Biosensing Diagnostic Tools > Diagnostic Nanodevices. © 2018 Wiley Periodicals, Inc.
Woolley, Joshua R; Kormos, Robert L; Teuteberg, Jeffrey J; Bermudez, Christian A; Bhama, Jay K; Lockard, Kathleen L; Kunz, Nicole M; Wagner, William R
2015-03-01
Preoperative liver dysfunction may influence haemostasis following ventricular assist device (VAD) implantation. The Model for End-stage Liver Disease (MELD) score was assessed as a predictor of bleeding and levels of haemostatic markers in patients with currently utilized VADs. Sixty-three patients (31 HeartMate II, 15 HeartWare, 17 Thoratec paracorporeal ventricular assist device) implanted 2001-11 were analysed for preoperative liver dysfunction (MELD) and blood product administration. Of these patients, 21 had additional blood drawn to measure haemostatic marker levels. Cohorts were defined based on high (≥18.0, n = 7) and low (<18.0, n = 14) preoperative MELD scores. MELD score was positively correlated with postoperative administration of red blood cell (RBC), platelet, plasma and total blood product units (TBPU) , as well as chest tube drainage and cardiopulmonary bypass time. Age and MELD were preoperative predictors of TBPU by multivariate analysis. The high-MELD cohort had higher administration of TBPU, RBC and platelet units and chest tube drainage postimplant. Similarly, patients who experienced at least one bleeding adverse event were more likely to have had a high preoperative MELD. The high-MELD group exhibited different temporal trends in F1 + 2 levels and platelet counts to postoperative day (POD) 55. D-dimer levels in high-MELD patients became elevated versus those for low-MELD patients on POD 55. Preoperative MELD score predicts postoperative bleeding in contemporary VADs. Preoperative liver dysfunction may also alter postoperative subclinical haemostasis through different temporal trends of thrombin generation and platelet counts, as well as protracted fibrinolysis. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Azzarà, A; Chimenti, M
2004-01-01
One of the main techniques used to explore neutrophil motility, employs micropore filters in chemotactic chambers. Many new models have been proposed, in order to perform multiple microassays in a rapid, inexpensive and reproducible way. In this work, LEGO bricks have been used as chemotactic chambers in the evaluation of neutrophil random motility and chemotaxis and compared with conventional Boyden chambers in a "time-response" experiment. Neutrophil motility throughout the filters was evaluated by means of an image-processing workstation, in which a dedicated algorithm recognizes and counts the cells in several fields and focal planes throughout the whole filter; correlates counts and depth values; performs a statistical analysis of data; calculates the true value of neutrophil migration; determines the distribution of cells; and displays the migration pattern. By this method, we found that the distances travelled by the cells in conventional chambers and in LEGO bricks were perfectly identical, both in random migration and under chemotactic conditions. Moreover, no interference with the physiological behaviour of neutrophils was detectable. In fact, the kinetics of migration was identical both in random migration (characterized by a gaussian pattern) and in chemotaxis (characterized by a typical stimulation peak, previously identified by our workstation). In conclusion, LEGO bricks are extremely precise devices. They are simple to use and allow the use of small amounts of chemoattractant solution and cell suspension, supplying by itself a triplicate test. LEGO bricks are inexpensive, fast and suitable for current diagnostic activity or for research investigations in every laboratory.
The dynamics of health in wild field vole populations: a haematological perspective
Beldomenico, Pablo M.; Telfer, Sandra; Gebert, Stephanie; Lukomski, Lukasz; Bennett, Malcolm; Begon, Michael
2010-01-01
Summary Pathogens have been proposed as potentially important drivers of population dynamics, but while a few studies have investigated the impact of specific pathogens, the wealth of information provided by general indices of health has hardly been exploited. By evaluating haematological parameters in wild populations, our knowledge of the dynamics of health and infection may be better understood. Here, haematological dynamics in natural populations of field voles are investigated to determine environmental and host factors associated with indicators of inflammatory response (counts of monocytes and neutrophils) and of condition: measures of immunological investment (lymphocyte counts) and aerobic capacity (red blood cell counts). Individuals from three field vole populations were sampled monthly for 2 years. Comparisons with individuals kept under controlled conditions facilitated interpretation of field data. Mixed effects models were developed for each cell type to evaluate separately the effects of various factors on post-juvenile voles and mature breeding females. There were three well-characterized ‘physiological’ seasons. The immunological investment appeared lowest in winter (lowest lymphocyte counts), but red blood cells were at their highest levels and indices of inflammatory response at their lowest. Spring was characterized by a fall in red blood cell counts and peaks in indicators of inflammatory response. During the course of summer—autumn, red blood cell counts recovered, the immunological investment increased and the indicators of inflammatory response decreased. Poor body condition appeared to affect the inflammatory response (lower neutrophil and monocyte peaks) and the immunological investment (lower lymphocyte counts), providing evidence that the capacity to fight infection is dependent upon host condition. Breeding early in the year was most likely in females in better condition (high lymphocyte and red blood cell counts). All the haematological parameters were affected adversely by high population densities. PMID:18564292
Hahn, Robert G
2017-01-01
A high number of blood cells increases the viscosity of the blood. The present study explored whether variations in blood cell counts are relevant to the distribution and elimination of infused crystalloid fluid. On three different occasions, 10 healthy male volunteers received an intravenous infusion of 25mL/kg of Ringer's acetate, Ringer's lactate, and isotonic saline over 30min. Blood hemoglobin and urinary excretion were monitored for 4h and used as input in a two-volume kinetic model, using nonlinear mixed effects software. The covariates used in the kinetic model were red blood cell and platelet counts, the total leukocyte count, the use of isotonic saline, and the arterial pressure. Red blood cell and platelet counts in the upper end of the normal range were associated with a decreased rate of distribution and redistribution of crystalloid fluid. Simulations showed that high counts were correlated with volume expansion of the peripheral (interstitial) fluid space, while the plasma volume was less affected. In contrast, the total leukocyte count had no influence on the distribution, redistribution, or elimination. The use of isotonic saline caused a transient reduction in the systolic arterial pressure (P<0.05) and doubled the half-life of infused fluid in the body when compared to the two Ringer solutions. Isotonic saline did not decrease the serum potassium concentration, despite the fact that saline is potassium-free. High red blood cell and platelet counts are associated with peripheral accumulation of infused crystalloid fluid. Copyright © 2017 The Lithuanian University of Health Sciences. Production and hosting by Elsevier Sp. z o.o. All rights reserved.
Image-based red cell counting for wild animals blood.
Mauricio, Claudio R M; Schneider, Fabio K; Dos Santos, Leonilda Correia
2010-01-01
An image-based red blood cell (RBC) automatic counting system is presented for wild animals blood analysis. Images with 2048×1536-pixel resolution acquired on an optical microscope using Neubauer chambers are used to evaluate RBC counting for three animal species (Leopardus pardalis, Cebus apella and Nasua nasua) and the error found using the proposed method is similar to that obtained for inter observer visual counting method, i.e., around 10%. Smaller errors (e.g., 3%) can be obtained in regions with less grid artifacts. These promising results allow the use of the proposed method either as a complete automatic counting tool in laboratories for wild animal's blood analysis or as a first counting stage in a semi-automatic counting tool.
2D dark-count-rate modeling of PureB single-photon avalanche diodes in a TCAD environment
NASA Astrophysics Data System (ADS)
Knežević, Tihomir; Nanver, Lis K.; Suligoj, Tomislav
2018-02-01
PureB silicon photodiodes have nm-shallow p+n junctions with which photons/electrons with penetration-depths of a few nanometer can be detected. PureB Single-Photon Avalanche Diodes (SPADs) were fabricated and analysed by 2D numerical modeling as an extension to TCAD software. The very shallow p+ -anode has high perimeter curvature that enhances the electric field. In SPADs, noise is quantified by the dark count rate (DCR) that is a measure for the number of false counts triggered by unwanted processes in the non-illuminated device. Just like for desired events, the probability a dark count increases with increasing electric field and the perimeter conditions are critical. In this work, the DCR was studied by two 2D methods of analysis: the "quasi-2D" (Q-2D) method where vertical 1D cross-sections were assumed for calculating the electron/hole avalanche-probabilities, and the "ionization-integral 2D" (II-2D) method where crosssections were placed where the maximum ionization-integrals were calculated. The Q-2D method gave satisfactory results in structures where the peripheral regions had a small contribution to the DCR, such as in devices with conventional deepjunction guard rings (GRs). Otherwise, the II-2D method proved to be much more precise. The results show that the DCR simulation methods are useful for optimizing the compromise between fill-factor and p-/n-doping profile design in SPAD devices. For the experimentally investigated PureB SPADs, excellent agreement of the measured and simulated DCR was achieved. This shows that although an implicit GR is attractively compact, the very shallow pn-junction gives a risk of having such a low breakdown voltage at the perimeter that the DCR of the device may be negatively impacted.
Wagner, Alixandra; Eldawud, Reem; White, Andrew; Agarwal, Sushant; Stueckle, Todd A.; Sierros, Konstantinos A.; Rojanasakul, Yon; Gupta, Rakesh K.; Dinu, Cerasela Zoica
2016-01-01
Background Montmorillonite is a type of nanoclay that originates from the clay fraction of the soil and is incorporated into polymers to form nanocomposites with enhanced mechanical strength, barrier, and flammability properties used for food packaging, automotive, and medical devices. However, with implementation in such consumer applications, the interaction of montmorillonite-based composites or derived byproducts with biological systems needs to be investigated. Methods Herein we examined the potential of Cloisite Na+ (pristine) and Cloisite 30B (organically modified montmorillonite nanoclay) and their thermally degraded byproducts’ to induce toxicity in model human lung epithelial cells. The experimental set-up mimicked biological exposure in manufacturing and disposal areas and employed cellular treatments with occupationally relevant doses of nanoclays previously characterized using spectroscopical and microscopical approaches. For nanoclay-cellular interactions and for cellular analyses respectively, biosensorial-based analytical platforms were used, with induced cellular changes being confirmed via live cell counts, viability assays, and cell imaging. Results Our analysis of byproducts’ chemical and physical properties revealed both structural and functional changes. Real-time high throughput analyses of exposed cellular systems confirmed that nanoclay induced significant toxic effects, with Cloisite 30B showing time-dependent decreases in live cell count and cellular viability relative to control and pristine nanoclay, respectively. Byproducts produced less toxic effects; all treatments caused alterations in the cell morphology upon exposure. Conclusions Our morphological, behavioral, and viability cellular changes show that nanoclays have the potential to produce toxic effects when used both in manufacturing or disposal environments. General significance The reported toxicological mechanisms prove the extensibility of a biosensorial-based platform for cellular behavior analysis upon treatment with a variety of nanomaterials. PMID:27612663
Weinhold, Kent J; Bukowski, Jack F; Brennan, Todd V; Noveck, Robert J; Staats, Janet S; Lin, Liwen; Stempora, Linda; Hammond, Constance; Wouters, Ann; Mojcik, Christopher F; Cheng, John; Collinge, Mark; Jesson, Michael I; Hazra, Anasuya; Biswas, Pinaki; Lan, Shuping; Clark, James D; Hodge, Jennifer A
2018-06-01
This study evaluated the short-term effects of tofacitinib treatment on peripheral blood leukocyte phenotype and function, and the reversibility of any such effects following treatment withdrawal in healthy volunteers. Cytomegalovirus (CMV)-seropositive subjects received oral tofacitinib 10 mg twice daily for 4 weeks and were followed for 4 weeks after drug withdrawal. There were slight increases in total lymphocyte and total T-cell counts during tofacitinib treatment, and B-cell counts increased by up to 26%. There were no significant changes in granulocyte or monocyte counts, or granulocyte function. Naïve and central memory T-cell counts increased during treatment, while all subsets of activated T cells were decreased by up to 69%. T-cell subsets other than effector memory cluster of differentiation (CD)4+, activated naïve CD4+ and effector CD8+ T-cell counts and B-cell counts, normalized 4 weeks after withdrawal. Following ex vivo activation, measures of CMV-specific T-cell responses, and antigen non-specific T-cell-mediated cytotoxicity and interferon (IFN)-γ production, decreased slightly. These T-cell functional changes were most pronounced at Day 15, partially normalized while still on tofacitinib and returned to baseline after drug withdrawal. Total natural killer (NK)-cell counts decreased by 33%, returning towards baseline after drug withdrawal. NK-cell function decreased during tofacitinib treatment, but without a consistent time course across measured parameters. However, markers of NK-cell-mediated cytotoxicity, antibody-dependent cellular cytotoxicity and IFN-γ production were decreased up to 42% 1 month after drug withdrawal. CMV DNA was not detectable in whole blood, and there were no cases of herpes zoster reactivation. No new safety concerns arose. In conclusion, the effect of short-term tofacitinib treatment on leukocyte composition and function in healthy CMV+ volunteers is modest and largely reversible 4 weeks after withdrawal. Copyright © 2018 Pfizer Inc. Published by Elsevier Inc. All rights reserved.
Oscillatory haematopoiesis in adults with sickle cell disease treated with hydroxycarbamide.
Baird, John H; Minniti, Caterina P; Lee, Jung-Min; Tian, Xin; Wu, Colin; Jackson, Mary; Alam, Shoaib; Taylor, James G; Kato, Gregory J
2015-03-01
Hydroxycarbamide therapy has been associated with significant oscillations in peripheral blood counts from myeloid, lymphoid and erythroid lineages in patients with polycythaemia vera and chronic myeloid leukaemia. We retrospectively evaluated serial blood counts over an 8-year period from 44 adult patients with sickle cell disease receiving hydroxycarbamide. Platelet counts, leucocyte counts, haemoglobin values and reticulocyte counts, apportioned by hydroxycarbamide status, were analysed using a Lomb-Scargle periodogram algorithm. Significant periodicities were present in one or more counts in 38 patients receiving hydroxycarbamide for a mean duration of 4·81 years. Platelet and leucocyte counts oscillated in 56·8% and 52·3% of patients, respectively. These oscillations generally became detectable within days of initiating therapy. During hydroxycarbamide therapy, the predominant periods of oscillation were 27 ± 1 d for platelet counts and 15 ± 1 d for leucocyte counts. Despite an absolute decrease in leucocyte and platelet counts during hydroxycarbamide treatment, the amplitudes between nadirs and zeniths remained similar regardless of exposure. Our observations appear consistent with previously proposed models of cyclic haematopoiesis, and document that hydroxycarbamide-induced oscillations in blood counts are innocuous phenomena not limited to myeloproliferative disorders as described previously. We speculate the known cell cycle inhibitory properties of hydroxycarbamide may accentuate otherwise latent constitutive oscillatory haematopoiesis. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
Correlation between normal glucose-6-phosphate dehydrogenase level and haematological parameters.
Ajlaan, S K; al-Naama, L M; al-Naama, M M
2000-01-01
The study involved 143 individuals and aimed to correlate normal glucose-6-phosphate dehydrogenase (G6PD) level with haematological parameters. A statistically significant negative correlation was found between G6PD level and haemoglobin, packed cell volume, red blood cell count, mean corpuscular haemoglobin and mean corpuscular volume. A statistically significant positive correlation was found between G6PD level and white blood cell count and reticulocyte count, but no significant correlation was found between G6PD level and mean corpuscular haemoglobin concentration. The negative correlation between G6PD level and haemoglobin suggests that anaemic people have higher G6PD levels than normal individuals. The positive correlation between G6PD level and white blood cell count indicates that white blood cells may play an important role in contributing to G6PD level.
Greene, C; Wu, J; Rickard, A H; Xi, C
2016-10-01
The human opportunistic pathogen, Acinetobacter baumannii, has the propensity to form biofilms and frequently cause medical device-related infections in hospitals. However, the physio-chemical properties of medical surfaces, in addition to bacterial surface properties, will affect colonization and biofilm development. The objective of this study was to compare the ability of A. baumannii to form biofilms on six different materials common to the hospital environment: glass, porcelain, stainless steel, rubber, polycarbonate plastic and polypropylene plastic. Biofilms were developed on material coupons in a CDC biofilm reactor. Biofilms were visualized and quantified using fluorescent staining and imaged using confocal laser scanning microscopy (CLSM) and by direct viable cell counts. Image analysis of CLSM stacks indicated that the mean biomass values for biofilms grown on glass, rubber, porcelain, polypropylene, stainless steel and polycarbonate were 0·04, 0·26, 0·62, 1·00, 2·08 and 2·70 μm(3) /μm(2) respectively. Polycarbonate developed statistically more biofilm mass than glass, rubber, porcelain and polypropylene. Viable cell counts data were in agreement with the CLSM-derived data. In conclusion, polycarbonate was the most accommodating surface for A. baumannii ATCC 17978 to form biofilms while glass was least favourable. Alternatives to polycarbonate for use in medical and dental devices may need to be considered. In the hospital environment, Acinetobacter baumannii is one of the most persistent and difficult to control opportunistic pathogens. The persistence of A. baumannii is due, in part, to its ability to colonize surfaces and form biofilms. This study demonstrates that A. baumannii can form biofilms on a variety of different surfaces and develops substantial biofilms on polycarbonate - a thermoplastic material that is often used in the construction of medical devices. The findings highlight the need to further study the in vitro compatibility of medical materials that could be colonized by A. baumannii and allow it to persist in hospital settings. © 2016 The Society for Applied Microbiology.
Nakanjako, Damalie; Kiragga, Agnes N.; Musick, Beverly S.; Yiannoutsos, Constantin T.; Wools-Kaloustian, Kara; Diero, Lameck; Oyaro, Patrick; Lugina, Emanuel; Ssali, John C.; Kambugu, Andrew; Easterbrook, Philippa
2017-01-01
Objective To describe patterns of suboptimal immune recovery (SO-IR) and associated HIV-related-illnesses during the first 5 years following first-line antiretroviral therapy (ART) initiation across seven ART sites in East Africa. Design Retrospective analysis of data from seven ART clinical sites (three Uganda, two Kenya and two Tanzania). Methods SO-IR was described by proportions of ART-treated adults with CD4+ cell counts less than 200, less than 350 and less than 500 cells/μl. Kaplan–Meier survival analysis techniques were used to assess predictors of SO-IR, and incident rates of HIV-related illnesses at CD4+ cell counts less than 200, 200–350, 351–499, and >500 cells/μl, respectively. Results Overall 80 843 adults initiated non-nucleoside reverse transcriptase inhibitor-based first-line ART; 65% were women and median CD4+ cell count was 126 [interquartile range (IQR), 52–202] cells/μl. Cumulative probability of SO-IR <200 cells/μl, <350 cells/μl and <500 cells/μl, after 5 years, was 11, 38 and 63%, respectively. Incidence of HIV-related illnesses was higher among those with CD4+ cell counts less than 200 and 200–350 cells/μl, than those who achieved CD4 counts above these thresholds. The most common events, at CD4 <200 cells/μl, were pulmonary tuberculosis [incident rate 15.98 (15.47–16.51)/100 person-years at risk (PYAR), oral candidiasis [incident rate 12.5 (12.03–12.94)] and herpes zoster [incident rate 6.30 (5.99–6.64)] events/100 PYAR. With attainment of a CD4+ cell count level 200–350 cells/μl, there was a substantial reduction in events/100 PYAR – by 91% to 1.45 (1.29–1.63) for TB, by 94% to 0.75 (0.64–0.89) for oral candidiasis, by 84% to 0.99 (0.86–1.14) for Herpes Zoster, and by 78% to 1.22 (1.07–1.39) for chronic diarrhea. The incidence of all events decreased further with CD4 counts above these thresholds. Conclusion Around 40% of adults initiated on ART have suboptimal immune recovery with CD4 counts <350 cells/ml after five years. Such patients will require closer monitoring for both HIV-related and non-HIV-related clinical events. PMID:26959510
Fluorometric determination of the DNA concentration in municipal drinking water.
McCoy, W F; Olson, B H
1985-01-01
DNA concentrations in municipal drinking water samples were measured by fluorometry, using Hoechst 33258 fluorochrome. The concentration, extraction, and detection methods used were adapted from existing techniques. The method is reproducible, fast, accurate, and simple. The amounts of DNA per cell for five different bacterial isolates obtained from drinking water samples were determined by measuring DNA concentration and total cell concentration (acridine orange epifluorescence direct cell counting) in stationary pure cultures. The relationship between DNA concentration and epifluorescence total direct cell concentration in 11 different drinking water samples was linear and positive; the amounts of DNA per cell in these samples did not differ significantly from the amounts in pure culture isolates. We found significant linear correlations between DNA concentration and colony-forming unit concentration, as well as between epifluorescence direct cell counts and colony-forming unit concentration. DNA concentration measurements of municipal drinking water samples appear to monitor changes in bacteriological quality at least as well as total heterotrophic plate counting and epifluorescence direct cell counting. PMID:3890737
Nishitani, Naoko; Sakakibara, Hisataka
2014-01-01
Relationships between work-related psychological and physical stress responses and counts of white blood cells (WBCs), neutrophils, and lymphocytes were investigated in 101 daytime workers. Counts of WBCs and neutrophils were positively associated with smoking and inversely correlated with high density lipoprotein (HDL)-cholesterol levels. Additionally, general fatigue score as measured by the profile of mood state was positively correlated with WBC and neutrophil counts whereas lymphocyte counts was not significantly associated with fatigue score. Multiple regression analysis showed that WBC count was significantly related to general fatigue, age, and HDL-cholesterol levels. Neutrophil count was significantly related to HDL-cholesterol levels and fatigue score. Among various psychological stress response variables, general fatigue may be a key determinant of low-grade inflammation as represented by increases of WBC and neutrophil counts.
Landis, Sarah; Suruki, Robert; Maskell, Joe; Bonar, Kerina; Hilton, Emma; Compton, Chris
2018-03-20
Blood eosinophil count may be a useful biomarker for predicting response to inhaled corticosteroids and exacerbation risk in chronic obstructive pulmonary disease (COPD) patients. The optimal cut point for categorizing blood eosinophil counts in these contexts remains unclear. We aimed to determine the distribution of blood eosinophil count in COPD patients and matched non-COPD controls, and to describe demographic and clinical characteristics at different cut points. We identified COPD patients within the UK Clinical Practice Research Database aged ≥40 years with a FEV 1 /FVC <0.7, and ≥1 blood eosinophil count recorded during stable disease between January 1, 2010 and December 31, 2012. COPD patients were matched on age, sex, and smoking status to non-COPD controls. Using all blood eosinophil counts recorded during a 12-month period, COPD patients were categorized as "always above," "fluctuating above and below," and "never above" cut points of 100, 150, and 300 cells/μL. The geometric mean blood eosinophil count was statistically significantly higher in COPD patients versus matched controls (196.6 cells/µL vs. 182.1 cells/µL; mean difference 8%, 95% CI: 6.8, 9.2), and in COPD patients with versus without a history of asthma (205.0 cells/µL vs. 192.2 cells/µL; mean difference 6.7%, 95%, CI: 4.9, 8.5). About half of COPD patients had all blood eosinophil counts above 150 cells/μL; this persistent higher eosinophil phenotype was associated with being male, higher body mass index, and history of asthma. In conclusion, COPD patients demonstrated higher blood eosinophil count than non-COPD controls, although there was substantial overlap in the distributions. COPD patients with a history of asthma had significantly higher blood eosinophil count versus those without.
Ebbo, Mikael; Gérard, Laurence; Carpentier, Sabrina; Vély, Frédéric; Cypowyj, Sophie; Farnarier, Catherine; Vince, Nicolas; Malphettes, Marion; Fieschi, Claire; Oksenhendler, Eric; Schleinitz, Nicolas; Vivier, Eric
2016-04-01
Natural Killer (NK) cells have been shown to exert antiviral and antitumoural activities. Nevertheless most available data are derived from mouse models and functions of these cells in human remain unclear. To evaluate the impact of low circulating NK cell counts and to provide some clues to the role of NK cells in natural conditions, we studied a large cohort of patients with common variable immunodeficiency (CVID) included in a multicenter cohort of patients with primary hypogammaglobulinaemia. Patients were classified into three groups on the basis of their NK cell counts: severe and mild NK cell lymphopenia (<50 and 50-99×10(6)/L respectively), and normal NK cell counts (>100×10(6)/L). Clinical events were analyzed and compared between these three groups of patients. During study period, 457 CVID patients were included: 99 (21.7%) with severe NK cell lymphopenia, 118 (25.8%) with mild NK cell lymphopenia and 240 (52.5%) with normal NK cell counts. Non-infectious complications (57% vs. 36% and 35%), and, particularly, granulomatous complications (25.3% vs. 13.6% and 8.8%), were more frequent in patients with severe NK cell lymphopenia than in other groups. Invasive infections (68.7% vs. 60.2% and 48.8%), including bacteraemia (22.2% vs. 5.9% and 8.3%) and infectious pneumonia (63.6% vs. 59.3% and 44.2%), were also more frequent in this population. However, no difference was observed for viral infections and neoplasms. Low circulating NK cell counts are associated with more severe phenotypes of CVID, which may indicate a protective role of these immune cells against severe bacterial infections and other complications and non-redundant immune functions when the adaptive immune response is not optimal. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Silicon Quantum Dots with Counted Antimony Donor Implants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, Meenakshi; Pacheco, Jose L.; Perry, Daniel Lee
2015-10-01
Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.
High count-rate study of two TES x-ray microcalorimeters with different transition temperatures
NASA Astrophysics Data System (ADS)
Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.; Sadleir, John E.; Smith, Stephen J.; Wassell, Edward J.
2017-10-01
We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures (T c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T cs had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.3 eV at 6 keV from lower and higher T c devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the so-called event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96% throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T c (faster) device, and 5.8 eV FWHM with 97% throughput with the lower T c (slower) device at 722 Hz.
Medipix2 based CdTe microprobe for dental imaging
NASA Astrophysics Data System (ADS)
Vykydal, Z.; Fauler, A.; Fiederle, M.; Jakubek, J.; Svestkova, M.; Zwerger, A.
2011-12-01
Medical imaging devices and techniques are demanded to provide high resolution and low dose images of samples or patients. Hybrid semiconductor single photon counting devices together with suitable sensor materials and advanced techniques of image reconstruction fulfil these requirements. In particular cases such as the direct observation of dental implants also the size of the imaging device itself plays a critical role. This work presents the comparison of 2D radiographs of tooth provided by a standard commercial dental imaging system (Gendex 765DC X-ray tube with VisualiX scintillation detector) and two Medipix2 USB Lite detectors one equipped with a Si sensor (300 μm thick) and one with a CdTe sensor (1 mm thick). Single photon counting capability of the Medipix2 device allows virtually unlimited dynamic range of the images and thus increases the contrast significantly. The dimensions of the whole USB Lite device are only 15 mm × 60 mm of which 25% consists of the sensitive area. Detector of this compact size can be used directly inside the patients' mouth.
Death of the Escherichia coli K-12 strain W3110 in soil and water.
Bogosian, G; Sammons, L E; Morris, P J; O'Neil, J P; Heitkamp, M A; Weber, D B
1996-01-01
Whether Escherichia coli K-12 strain W3110 can enter the "viable but nonculturable" state was studied with sterile and nonsterile water and soil at various temperatures. In nonsterile river water, the plate counts of added E. coli cells dropped to less than 10 CFU/ml in less than 10 days. Acridine orange direct counts, direct viable counts, most-probable-number estimates, and PCR analyses indicated that the added E. coli cells were disappearing from the water in parallel with the number of CFU. Similar results were obtained with nonsterile soil, although the decline of the added E. coli was slower. In sterile water or soil, the added E. coli persisted for much longer, often without any decline in the plate counts even after 50 days. In sterile river water at 37 degrees C and sterile artificial seawater at 20 and 37 degrees C, the plate counts declined by 3 to 5 orders of magnitude, while the acridine orange direct counts remained unchanged. However, direct viable counts and various resuscitation studies all indicated that the nonculturable cells were nonviable. Thus, in either sterile or nonsterile water and soil, the decline in plate counts of E. coli K-12 strain W3110 is not due to the cells entering the viable but nonculturable state, but is simply due to their death. PMID:8900002
42 CFR 493.1276 - Standard: Clinical cytogenetics.
Code of Federal Regulations, 2010 CFR
2010-10-01
... of accessioning, cell preparation, photographing or other image reproduction technique, photographic... records that document the following: (1) The media used, reactions observed, number of cells counted, number of cells karyotyped, number of chromosomes counted for each metaphase spread, and the quality of...
Tanaskovic, Sara; Price, Patricia; French, Martyn A; Fernandez, Sonia
2017-02-01
HIV patients beginning antiretroviral therapy (ART) with advanced immunodeficiency often retain low CD4 + T cell counts despite virological control. We examined proliferative responses and upregulation of costimulatory molecules, following anti-CD3 stimulation, in HIV patients with persistent CD4 + T cell deficiency on ART. Aviremic HIV patients with nadir CD4 + T cell counts <100 cells/μL and who had received ART for a median time of 7 (range 1-11) years were categorized into those achieving low (<350 cells/μL; n = 13) or normal (>500 cells/μL; n = 20) CD4 + T cell counts. Ten healthy controls were also recruited. CD4 + T cell proliferation (Ki67) and upregulation of costimulatory molecules (CD27 and CD28) after anti-CD3 stimulation were assessed by flow cytometry. Results were related to proportions of CD4 + T cells expressing markers of T cell senescence (CD57), activation (HLA-DR), and apoptotic potential (Fas). Expression of CD27 and/or CD28 on uncultured CD4 + T cells was similar in patients with normal CD4 + T cell counts and healthy controls, but lower in patients with low CD4 + T cell counts. Proportions of CD4 + T cells expressing CD27 and/or CD28 correlated inversely with CD4 + T cell expression of CD57, HLA-DR, and Fas. After anti-CD3 stimulation, induction of CD27 hi CD28 hi expression was independent of CD4 + T cell counts, but lower in HIV patients than in healthy controls. Induction of CD27 hi CD28 hi expression correlated with induction of Ki67 expression in total, naïve, and CD31 + naïve CD4 + T cells from patients. In HIV patients responding to ART, impaired induction of CD27 and CD28 on CD4 + T cells after stimulation with anti-CD3 is associated with poor proliferative responses as well as greater CD4 + T cell activation and immunosenescence.
Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model.
Wilkinson, Holly N; McBain, Andrew J; Stephenson, Christian; Hardman, Matthew J
2016-11-01
Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze using a wounded porcine skin biofilm model with standardized application parameters. Biofilm removal was determined using a surface viability assay, bacterial counts, histological assessment, and scanning electron microscopy (SEM). Results: Quantitative analysis revealed that monofilament debriding devices outperformed the standard gauze, resulting in up to 100-fold greater reduction in bacterial counts. Interestingly, histological and morphological analyses suggested that debridement not only removed bacteria, but also differentially disrupted the bacterially-derived extracellular polymeric substance. Finally, SEM of post-debridement monofilaments showed structural changes in attached bacteria, implying a negative impact on viability. Innovation: This is the first study to combine controlled and defined debridement application with a biologically relevant ex vivo biofilm model to directly compare monofilament debriding devices. Conclusion: These data support the use of monofilament debriding devices for the removal of established wound biofilms and suggest variable efficacy towards biofilms composed of different species of bacteria.
Kesselring, Anouk M; Wit, Ferdinand W; Sabin, Caroline A; Lundgren, Jens D; Gill, M John; Gatell, Jose M; Rauch, Andri; Montaner, Julio S; de Wolf, Frank; Reiss, Peter; Mocroft, Amanda
2009-08-24
This collaboration of seven observational clinical cohorts investigated risk factors for treatment-limiting toxicities in both antiretroviral-naive and experienced patients starting nevirapine-based combination antiretroviral therapy (NVPc). Patients starting NVPc after 1 January 1998 were included. CD4 cell count at starting NVPc was classified as high (>400/microl/>250/microl for men/women, respectively) or low. Cox models were used to investigate risk factors for discontinuations due to hypersensitivity reactions (HSR, n = 6547) and discontinuation of NVPc due to treatment-limiting toxicities and/or patient/physician choice (TOXPC, n = 10,186). Patients were classified according to prior antiretroviral treatment experience and CD4 cell count/viral load at start NVPc. Models were stratified by cohort and adjusted for age, sex, nadir CD4 cell count, calendar year of starting NVPc and mode of transmission. Median time from starting NVPc to TOXPC and HSR were 162 days [interquartile range (IQR) 31-737] and 30 days (IQR 17-60), respectively. In adjusted Cox analyses, compared to naive patients with a low CD4 cell count, treatment-experienced patients with high CD4 cell count and viral load more than 400 had a significantly increased risk for HSR [hazard ratio 1.45, confidence interval (CI) 1.03-2.03] and TOXPC within 18 weeks (hazard ratio 1.34, CI 1.08-1.67). In contrast, treatment-experienced patients with high CD4 cell count and viral load less than 400 had no increased risk for HSR 1.10 (0.82-1.46) or TOXPC within 18 weeks (hazard ratio 0.94, CI 0.78-1.13). Our results suggest it may be relatively well tolerated to initiate NVPc in antiretroviral-experienced patients with high CD4 cell counts provided there is no detectable viremia.
Gezie, Lemma Derseh
2016-07-30
The response of HIV patients to antiretroviral therapy could be measured by its strong predictor, the CD4+ T cell (CD4) count for the initiation of antiretroviral therapy and proper management of disease progress. However, in addition to HIV, there are other factors which can influence the CD4 cell count. Patient's socio-economic, demographic, and behavioral variables, accessibility, duration of treatment etc., can be used to predict CD4 count. A retrospective cohort study was conducted to examine the predictors of CD4 count among ART users enrolled in the first 6 months of 2010 and followed upto mid 2014. The covariance components model was employed to determine the predictors of CD4 count over time. A total of 1196 ART attendants were used to analyze their data descriptively. Eight hundred sixty-one of the attendants had two or more CD4 count measurements and were used in modeling their data using the linear mixed method. Thus, the mean rates of incensement of CD4 counts for patients with ambulatory/bedridden and working baseline functional status were 17.4 and 30.6 cells/mm(3) per year, respectively. After adjusting for other variables, for each additional baseline CD4 count, the gain in CD4 count during treatment was 0.818 cells/mm(3) (p value <0.001). Patient's age and baseline functional status were also statistically significantly associated with CD4 count. In this study, higher baseline CD4 count, younger age, working functional status, and time in treatment contributed positively to the increment of the CD4 count. However, the observed increment at 4 year was unsatisfactory as the proportion of ART users who reached the normal range of CD4 count was very low. To see their long term treatment outcome, it requires further research with a sufficiently longer follow up data. In line with this, the local CD4 count for HIV negative persons should also be investigated for better comparison and proper disease management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liang, A K; Koniczek, M; Antonuk, L E
Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailedmore » circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.« less
Preimpoundment Water Quality of the Wild Rice River, Norman County, Minnesota.
1980-06-01
cell counts at Twin Valley for 1977 water year 25 14. Plot of total phosphorus related to phytoplankton cell counts at Twin Valley ; 30 15. Plot...of total nitrogen related to phytoplankton cell counts at Twin Valley 31 16. Bar graph of diversity indices of phytoplankton genera, 1976, 1977...statistically signifi- cant beyond the 0.02 level. There is no apparent relation of BOD to stream- flow or to suspended-sediment, phytoplankton , and bacteria
Development of a stained cell nuclei counting system
NASA Astrophysics Data System (ADS)
Timilsina, Niranjan; Moffatt, Christopher; Okada, Kazunori
2011-03-01
This paper presents a novel cell counting system which exploits the Fast Radial Symmetry Transformation (FRST) algorithm [1]. The driving force behind our system is a research on neurogenesis in the intact nervous system of Manduca Sexta or the Tobacco Hornworm, which was being studied to assess the impact of age, food and environment on neurogenesis. The varying thickness of the intact nervous system in this species often yields images with inhomogeneous background and inconsistencies such as varying illumination, variable contrast, and irregular cell size. For automated counting, such inhomogeneity and inconsistencies must be addressed, which no existing work has done successfully. Thus, our goal is to devise a new cell counting algorithm for the images with non-uniform background. Our solution adapts FRST: a computer vision algorithm which is designed to detect points of interest on circular regions such as human eyes. This algorithm enhances the occurrences of the stained-cell nuclei in 2D digital images and negates the problems caused by their inhomogeneity. Besides FRST, our algorithm employs standard image processing methods, such as mathematical morphology and connected component analysis. We have evaluated the developed cell counting system with fourteen digital images of Tobacco Hornworm's nervous system collected for this study with ground-truth cell counts by biology experts. Experimental results show that our system has a minimum error of 1.41% and mean error of 16.68% which is at least forty-four percent better than the algorithm without FRST.
Yanay, Ofer; Dale, David C.
2012-01-01
Abstract Cyclic neutropenia occurs in humans and gray collie dogs, is characterized by recurrent neutropenia, and is treated by repeated injections of recombinant granulocyte colony-stimulating factor (rG-CSF). As dose escalation of lentivirus may be clinically necessary, we monitored the outcome of four sequential intramuscular injections of G-CSF-lentivirus (3×107 IU/kg body weight) to a normal dog and a gray collie. In the normal dog absolute neutrophil counts were significantly increased after each dose of virus, with mean levels of 27.75±3.00, 31.50±1.40, 35.05±1.68, and 43.88±2.94×103 cells/μl, respectively (p<0.001), and elevated neutrophil counts of 31.18±7.81×103 cells/μl were maintained for more than 6 years with no adverse effects. A gray collie dog with a mean count of 1.94±1.48×103 cells/μl received G-CSF-lentivirus and we observed sustained elevations in neutrophil levels for more than 5 months with a mean of 26.00±11.00×103 cells/μl, significantly increased over the pretreatment level (p<0.001). After the second and third virus administrations mean neutrophil counts of 15.80±6.14 and 11.52±4.90×103 cells/μl were significantly reduced compared with cell counts after the first virus administration (p<0.001). However, after the fourth virus administration mean neutrophil counts of 15.21±4.50×103 cells/μl were significantly increased compared with the previous administration (p<0.05). Throughout the nearly 3 years of virus administrations the dog gained weight, was healthy, and showed neutrophil counts significantly higher than pretreatment levels (p<0.001). These studies suggest that patients with cyclic and other neutropenias may be treated with escalating doses of G-CSF-lentivirus to obtain a desired therapeutic neutrophil count. PMID:22845776
Spadaro, Savino; Kozhevnikova, Iryna; Casolari, Paolo; Ruggeri, Paolo; Bellini, Tiziana; Ragazzi, Riccardo; Barbieri, Federica; Marangoni, Elisabetta; Caramori, Gaetano; Volta, Carlo Alberto
2017-01-01
Our knowledge of acute respiratory distress syndrome (ARDS) pathogenesis is incomplete. The goal of this pilot study is to investigate the feasibility of measuring lower airways inflammation in patients with ARDS using repeated endotracheal aspirates (ETAs). ETAs were obtained within 24 hours by intensive care unit admission from 25 mechanically ventilated patients with ARDS and 10 of them underwent a second ETA within 96 hours after the first sampling. In each sample, cell viability was assessed using trypan blue exclusion method and the total and differential cell counts were measured using Neubauer-improved cell counting chamber and cytospins stained with Diff-Quik. The median cell viability was 89 (IQR 80-93)%, with a median total cell count of 305 (IQR 130-1270)×10 3 /mL and a median macrophage, neutrophil, lymphocyte and eosinophil count, respectively, of 19.8 (IQR 5.4-71.6)×10 3 /mL; 279 (IQR 109-1213)×10 3 /mL; 0 (IQR 0-0.188)×10 3 /mL; 0 (IQR 0-1.050)×10 3 /mL. Eosinophil count in the ETA correlated with the number of blood eosinophils (r=0.4840, p=0.0142). Cell viability and total and differential cell counts were neither significantly different in the second ETA compared with the first ETA nor were unaffected by the presence or absence of bacteria in the blood and/or ETA, or by the ARDS aetiology, apart from the macrophage count which was significantly increased in patients with ARDS associated with acute pancreatitis compared with those associated with pneumonia (p=0.0143). ETA can be used to investigate the cellularity of the lower airways in patients with ARDS and it is an easy-to-perform and non-invasive procedure. Eosinophil counts in ETA and blood are significantly correlated. The number of macrophages in ETA may be affected by the aetiology of the ARDS.
Stebbings, Richard; Wang, Lili; Sutherland, Janet; Kammel, Martin; Gaigalas, Adolfas K; John, Manuela; Roemer, Bodo; Kuhne, Maren; Schneider, Rudolf J; Braun, Michael; Engel, Andrea; Dikshit, Dinesh K; Abbasi, Fatima; Marti, Gerald E; Paola Sassi, Maria; Revel, Laura; Kim, Sook-Kyung; Baradez, Marc-Olivier; Lekishvili, Tamara; Marshall, Damian; Whitby, Liam; Jing, Wang; Ost, Volker; Vonsky, Maxim; Neukammer, Jörg
2015-01-01
A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) μL−1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment. © 2015 The Authors. Published by Wiley Periodicals, Inc. PMID:25655255
Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F
2005-10-01
To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P < .02) and 2.0 MPa (P < .005) relative to the cell counts at sham myocardial contrast echocardiography. Premature heartbeats had a similar exposure-response relationship; however, number of premature heartbeats and EB-stained cell count did not appear to be directly related (coefficient of determination r2 = 0.03). The EB-stained cell counts at end-diastolic triggering were not significantly different from those at end-systolic triggering (P > .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005
Kook, H; Goldman, F; Padley, D; Giller, R; Rumelhart, S; Holida, M; Lee, N; Peters, C; Comito, M; Huling, D; Trigg, M
1996-08-01
We prospectively studied immune reconstitution in 102 children who underwent T-lymphocyte depleted bone marrow transplants using either closely matched unrelated donors or partially matched familial donors by assaying total lymphocyte counts (TLC), T-cell subsets, B cells, and natural killer cells. TLC, CD3+, and CD4+ T-cell counts remained depressed until 2 to 3 years posttransplant, whereas CD8+ T-cell counts normalized by 18 months, resulting in an inverted CD4:CD8 ratio until 12 months posttransplant. Although the percentage of NK cells was elevated early posttransplant, their absolute numbers remained normal. CD20+ B cells were depressed until 12 to 18 months posttransplant. Factors affecting immunophenotypic recovery were analyzed by nonparametric statistics. Younger patients tended to have higher TLC posttransplant. Higher marrow cell doses were not associated with hastened immunophenotypic recovery. Graft-versus-host disease (GVHD) and/or its treatment significantly delayed the immune reconstitution of CD3+, CD4+, and CD20+ cells. The presence of cytomegalovirus was associated with increased CD8+ counts and a decrease in the percentages of CD4+ and CD20+ cells.
Martino, Massimo; Gori, Mercedes; Pitino, Annalisa; Gentile, Massimo; Dattola, Antonia; Pontari, Antonella; Vigna, Ernesto; Moscato, Tiziana; Recchia, Anna Grazia; Barilla', Santina; Tripepi, Giovanni; Morabito, Fortunato
2017-07-01
A longitudinal, prospective, observational, single-center, cohort study on healthy donors (HDs) was designed to identify predictors of CD34 + cells on day 5 with emphasis on the predictive value of the basal CD34 + cell count. As potential predictors of mobilization, age, sex, body weight, height, blood volume as well as white blood cell count, peripheral blood (PB) mononuclear cells, platelet count, hematocrit, and hemoglobin levels were considered. Two different evaluations of CD34 + cell counts were determined for each donor: baseline (before granulocyte colony-stimulating factor [G-CSF] administration) and in PB after G-CSF administration on the morning of the fifth day (day 5). A total of 128 consecutive HDs (66 males) with a median age of 43 years were enrolled. CD34 + levels on day 5 displayed a non-normal distribution, with a median value of 75.5 cells/µL. To account for the non-normal distribution of the dependent variable, a quantile regression analysis to predict CD34 + on day 5 using the baseline value of CD34 + as the key predictor was performed. On crude analysis, a baseline value of CD34 + ranging from .5 cells/µL to 1 cells/µL predicts a median value of 50 cells/µL on day 5; a value of 2 cells/µL predicts a median value of 70.7 cells/µL; a value of 3 cells/µL to 4 cells/µL predicts a median value of 91.3 cells/µL, and a value ≥ 5 predicts a median value of 112 cells/µL. In conclusion, the baseline PB CD34 + cell count correlates with the effectiveness of allogeneic PB stem cell mobilization and could be useful to plan the collection. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Robbins, Michael; Szapocznik, José; Tejeda, Manuel; Samuels, Deanne; Ironson, Gail; Antoni, Michael
2005-01-01
This study examined the role of family functioning and social support in protecting HIV-positive African American women from the adverse psychological consequences associated with deterioration in their CD4 cell count. Participants were 38 African American HIV-positive women who had recently given birth. Results demonstrated that changes in CD4 cell counts were inversely predictive of psychological distress and were moderated by family functioning and social support satisfaction. Women with good family functioning were less affected by changes in their CD4 cell counts, and women with poor family functioning were more emotionally responsive to changes in CD4 cell count. Unexpectedly, women from families where conflicts tended to be clearly laid out and discussed were also more responsive to both changes in CD4 cell counts. Interventions are recommended that increase a client’s social support satisfaction, foster an adaptive level of connectedness to family, and enhance the family’s range of conflict resolution styles. PMID:16609750
Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A
2015-06-01
Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.
Feldman, B F; Ruehl, W W
1984-04-01
In dogs, the pericardial sac contains about 0.3 ml, and the pleural and peritoneal cavities 0-15 ml of clear, straw-colored fluid of pH 7.4, specific gravity 1.016, protein content less than 3.0 g/dl and cell count less than 3000/microliter. Fat can be cleared from chylous fluid with NaOH and ether. Inflammation is indicated by a cell count greater than 3000/microliter. Amylase levels in peritoneal fluid are elevated in necrotizing pancreatitis. The percentage of polymorphonuclear WBC exceeds 50% in bacterial inflammations. Normal joints contain less than 1 ml highly viscid, clear or straw-colored synovial fluid with less than 1000 nucleated cells/microliter. Synovial fluid becomes flocculent and less viscid in septic and occasionally in immune-mediated arthritis, often with cell counts greater than 75,000/microliter, with 75-90% polymorphonuclear WBC. Cerebrospinal fluid is normally acellular, clear and colorless but may be red, yellow or brown with intracranial hematomas. Viral or aseptic meningitis is characterized by mononuclear cell counts of less than 500/microliter. In acute bacterial meningitis, nucleated cell counts are greater than 1000/microliter, with most being polymorphonuclear WBC. Gram staining of cerebrospinal fluid is not useful.
Sumpter, Beth; Dunham, Richard; Gordon, Shari; Engram, Jessica; Hennessy, Margaret; Kinter, Audrey; Paiardini, Mirko; Cervasi, Barbara; Klatt, Nichole; McClure, Harold; Milush, Jeffrey M; Staprans, Silvija; Sodora, Donald L; Silvestri, Guido
2007-02-01
In contrast to HIV-infected humans, naturally SIV-infected sooty mangabeys (SMs) very rarely progress to AIDS. Although the mechanisms underlying this disease resistance are unknown, a consistent feature of natural SIV infection is the absence of the generalized immune activation associated with HIV infection. To define the correlates of preserved CD4(+) T cell counts in SMs, we conducted a cross-sectional immunological study of 110 naturally SIV-infected SMs. The nonpathogenic nature of the infection was confirmed by an average CD4(+) T cell count of 1,076 +/- 589/mm(3) despite chronic infection with a highly replicating virus. No correlation was found between CD4(+) T cell counts and either age (used as a surrogate marker for length of infection) or viremia. The strongest correlates of preserved CD4(+) T cell counts were a low percentage of circulating effector T cells (CD28(-)CD95(+) and/or IL-7R/CD127(-)) and a high percentage of CD4(+)CD25(+) T cells. These findings support the hypothesis that the level of immune activation is a key determinant of CD4(+) T cell counts in SIV-infected SMs. Interestingly, we identified 14 animals with CD4(+) T cell counts of <500/mm(3), of which two show severe and persistent CD4(+) T cell depletion (<50/mm(3)). Thus, significant CD4(+) T cell depletion does occasionally follow SIV infection of SMs even in the context of generally low levels of immune activation, lending support to the hypothesis of multifactorial control of CD4(+) T cell homeostasis in this model of infection. The absence of AIDS in these "CD4(low)" naturally SIV-infected SMs defines a protective role of the reduced immune activation even in the context of a significant CD4(+) T cell depletion.
The Characteristics of User-Generated Passwords
1990-03-01
electronic keys), user interface tokens (pocket devices that can generate one-time passwords) and fixed password devices ( plastic cards that contain...APPENDIX B-7 DIFFREM DIFFICULTY REMfEIBERING by PASSCHAR PASSORD CARACTERISTICS PASSCHAR Pate I of 1 Count 1 Row Pet IALPHAVET NUMERIC ALPHANUM ASCII Cal Pet
Code of Federal Regulations, 2012 CFR
2012-07-01
... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...
Code of Federal Regulations, 2013 CFR
2013-07-01
... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...
Code of Federal Regulations, 2014 CFR
2014-07-01
... centerline. Bow sprits, bumpkins, rudders, outboard motor brackets, and similar fittings or attachments are... milliliters and no visible floating solids. Type II marine sanitation device means a device that, under the... bacteria count not greater than 200 per 100 milliliters and suspended solids not greater than 150...
Lithium and boron based semiconductors for thermal neutron counting
NASA Astrophysics Data System (ADS)
Kargar, Alireza; Tower, Joshua; Hong, Huicong; Cirignano, Leonard; Higgins, William; Shah, Kanai
2011-09-01
Thermal neutron detectors in planar configuration were fabricated from LiInSe2 and B2Se3 crystals grown at RMD Inc. All fabricated semiconductor devices were characterized for the current-voltage (I-V) characteristic and neutron counting measurement. Pulse height spectra were collected from 241AmBe (neutron source on all samples), as well as 137Cs and 60Co gamma ray sources. In this study, the resistivity of all crystals is reported and the collected pulse height spectra are presented for fabricated devices. Note that, the 241AmBe neutron source was custom designed with polyethylene around the source as the neutron moderator, mainly to thermalize the fast neutrons before reaching the detectors. Both LiInSe2 and B2Se3 devices showed response to thermal neutrons of the 241AmBe source.
NASA Astrophysics Data System (ADS)
Sopczak, André; Ali, Babar; Asawatavonvanich, Thanawat; Begera, Jakub; Bergmann, Benedikt; Billoud, Thomas; Burian, Petr; Caicedo, Ivan; Caforio, Davide; Heijne, Erik; Janeček, Josef; Leroy, Claude; Mánek, Petr; Mochizuki, Kazuya; Mora, Yesid; Pacík, Josef; Papadatos, Costa; Platkevič, Michal; Polanský, Štěpán; Pospíšil, Stanislav; Suk, Michal; Svoboda, Zdeněk
2017-03-01
A network of Timepix (TPX) devices installed in the ATLAS cavern measures the LHC luminosity as a function of time as a stand-alone system. The data were recorded from 13-TeV proton-proton collisions in 2015. Using two TPX devices, the number of hits created by particles passing the pixel matrices was counted. A van der Meer scan of the LHC beams was analyzed using bunch-integrated luminosity averages over the different bunch profiles for an approximate absolute luminosity normalization. It is demonstrated that the TPX network has the capability to measure the reduction of LHC luminosity with precision. Comparative studies were performed among four sensors (two sensors in each TPX device) and the relative short-term precision of the luminosity measurement was determined to be 0.1% for 10-s time intervals. The internal long-term time stability of the measurements was below 0.5% for the data-taking period.
Ishii, Takeo; Hizawa, Nobuyuki; Midwinter, Dawn; James, Mark; Hilton, Emma; Jones, Paul W
2018-01-01
Background Blood eosinophil measurements may help to guide physicians on the use of inhaled corticosteroids (ICS) for patients with chronic obstructive pulmonary disease (COPD). Emerging data suggest that COPD patients with higher blood eosinophil counts may be at higher risk of exacerbations and more likely to benefit from combined ICS/long-acting beta2-agonist (LABA) treatment than therapy with a LABA alone. This analysis describes the distribution of blood eosinophil count at baseline in Japanese COPD patients in comparison with non-Japanese COPD patients. Methods A post hoc analysis of eosinophil distribution by percentage and absolute cell count was performed across 12 Phase II–IV COPD clinical studies (seven Japanese studies [N=848 available absolute eosinophil counts] and five global studies [N=5,397 available eosinophil counts] that included 246 Japanese patients resident in Japan with available counts). Blood eosinophil distributions were assessed at baseline, before blinded treatment assignment. Findings Among Japanese patients, the median (interquartile range) absolute eosinophil count was 170 cells/mm3 (100–280 cells/mm3). Overall, 612/1,094 Japanese patients (56%) had an absolute eosinophil count ≥150 cells/mm3 and 902/1,304 Japanese patients (69%) had a percentage eosinophil ≥2%. Among non-Japanese patients, these values were 160 (100–250) cells/mm3, 2,842/5,151 patients (55%), and 2,937/5,155 patients (57%), respectively. The eosinophil distribution among Japanese patients was similar to that among non-Japanese patients. Within multi-country studies with similar inclusion criteria, the eosinophil count was numerically lower in Japanese compared with non-Japanese patients (median 120 vs 160 cells/mm3). Interpretation The eosinophil distribution in Japanese patients seems comparable to that of non-Japanese patients; although within multi-country studies, there was a slightly lower median eosinophil count for Japanese patients compared with non-Japanese patients. These findings suggest that blood eosinophil data from global studies are of relevance in Japan. PMID:29440882
Webber, Sandra C; Magill, Sheila M; Schafer, Jenessa L; Wilson, Kaylie C S
2014-07-01
The purpose was to compare step count accuracy of an accelerometer (ActiGraph GT3X+), a mechanical pedometer (Yamax SW200), and a piezoelectric pedometer (SC-StepMX). Older adults (n = 13 with walking aids, n = 22 without; M = 81.5 years old, SD = 5.0) walked 100 m wearing the devices. Device-detected steps were compared with manually counted steps. We found no significant differences among monitors for those who walked without aids (p = .063). However, individuals who used walking aids exhibited slower gait speeds (M = 0.83 m/s, SD = 0.2) than non-walking aid users (M = 1.21 m/s, SD = 0.2, p < .001), and for them the SC-StepMX demonstrated a significantly lower percentage of error (Mdn = 1.0, interquartile range [IQR] = 0.5-2.0) than the other devices (Yamax SW200, Mdn = 68.9, IQR = 35.9-89.3; left GT3X+, Mdn = 52.0, IQR = 37.1-58.9; right GT3X+, Mdn = 51.0, IQR = 32.3-66.5; p < .05). These results support using a piezoelectric pedometer for measuring steps in older adults who use walking aids and who walk slowly.
Comparative Analysis of Gender Differences in the HIV-1 Infection Dynamics
NASA Astrophysics Data System (ADS)
Ballesteros, P.; Estrada, J. L.; Barriga, G.; Molinar, F.; Hernández, M. C.; Huerta, L.; Cocho, G.; Villarreal, C.
2006-09-01
We have performed a retrospective study of the HIV-1 viral load and CD4 T-cell counts in blood plasma of more than 3000 Mexican patients. We found that women had consistently lower viral loads than men for CD4 T-cell counts higher than 50 cells/μL and higher viral loads when CD4 T-cell counts were at most 50 cells/μL. Our results show the same pattern as the one reported in studies performed in European and North American populations. We present theoretical predictions of viral load dynamics during highly active antiretroviral therapy taking into account gender differences.
Formation and resuscitation of viable but nonculturable Salmonella typhi.
Zeng, Bin; Zhao, Guozhong; Cao, Xiaohong; Yang, Zhen; Wang, Chunling; Hou, Lihua
2013-01-01
Salmonella typhi is a pathogen that causes the human disease of typhoid fever. The aim of this study was to investigate the viable but nonculturable (VBNC) state of S. typhi. Some samples were stimulated at 4°C or -20°C, while others were induced by different concentrations of CuSO4. Total cell counts remained constant throughout several days by acridine orange direct counting; however, plate counts declined to undetectable levels within 48 hours by plate counting at -20°C. The direct viable counts remained fairly constant at this level by direct viable counting. Carbon and nitrogen materials slowly decreased which indicated that a large population of cells existed in the VBNC state and entered the VBNC state in response to exposure to 0.01 or 0.015 mmol/L CuSO4 for more than 14 or 12 days, respectively. Adding 3% Tween 20 or 1% catalase enabled cells to become culturable again, with resuscitation times of 48 h and 24 h, respectively. The atomic force microscope results showed that cells gradually changed in shape from short rods to coccoids, and decreased in size when they entered the VBNC state. Further animal experiments suggested that resuscitated cells might regain pathogenicity.
New method for estimating bacterial cell abundances in natural samples by use of sublimation
NASA Technical Reports Server (NTRS)
Glavin, Daniel P.; Cleaves, H. James; Schubert, Michael; Aubrey, Andrew; Bada, Jeffrey L.
2004-01-01
We have developed a new method based on the sublimation of adenine from Escherichia coli to estimate bacterial cell counts in natural samples. To demonstrate this technique, several types of natural samples, including beach sand, seawater, deep-sea sediment, and two soil samples from the Atacama Desert, were heated to a temperature of 500 degrees C for several seconds under reduced pressure. The sublimate was collected on a cold finger, and the amount of adenine released from the samples was then determined by high-performance liquid chromatography with UV absorbance detection. Based on the total amount of adenine recovered from DNA and RNA in these samples, we estimated bacterial cell counts ranging from approximately 10(5) to 10(9) E. coli cell equivalents per gram. For most of these samples, the sublimation-based cell counts were in agreement with total bacterial counts obtained by traditional DAPI (4,6-diamidino-2-phenylindole) staining.
Ahmed, Anwar E; Ali, Yosra Z; Al-Suliman, Ahmad M; Albagshi, Jafar M; Al Salamah, Majid; Elsayid, Mohieldin; Alanazi, Wala R; Ahmed, Rayan A; McClish, Donna K; Al-Jahdali, Hamdan
2017-01-01
High white blood cell (WBC) count is an indicator of sickle cell disease (SCD) severity, however, there are limited studies on WBC counts in Saudi Arabian patients with SCD. The aim of this study was to estimate the prevalence of abnormal leukocyte count (either low or high) and identify factors associated with high WBC counts in a sample of Saudi patients with SCD. A cross-sectional and retrospective chart review study was carried out on 290 SCD patients who were routinely treated at King Fahad Hospital in Hofuf, Saudi Arabia. An interview was conducted to assess clinical presentations, and we reviewed patient charts to collect data on blood test parameters for the previous 6 months. Almost half (131 [45.2%]) of the sample had abnormal leukocyte counts: low WBC counts 15 (5.2%) and high 116 (40%). High WBC counts were associated with shortness of breath ( P =0.022), tiredness ( P =0.039), swelling in hands/feet ( P =0.020), and back pain ( P =0.007). The mean hemoglobin was higher in patients with normal WBC counts ( P =0.024), while the mean hemoglobin S was high in patients with high WBC counts ( P =0.003). After adjustment for potential confounders, predictors of high WBC counts were male gender (adjusted odds ratio [aOR]=3.63) and patients with cough (aOR=2.18), low hemoglobin (aOR=0.76), and low heart rate (aOR=0.97). Abnormal leukocyte count was common: approximately five in ten Saudi SCD patients assessed in this sample. Male gender, cough, low hemoglobin, and low heart rate were associated with high WBC count. Strategies targeting high WBC count could prevent disease complication and thus could be beneficial for SCD patients.
Chip-based in situ hybridization for identification of bacteria from the human microbiome.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Light, Yooli Kim; Meagher, Robert J.; Singh, Anup K.
2010-11-01
The emerging field of metagenomics seeks to assess the genetic diversity of complex mixed populations of bacteria, such as those found at different sites within the human body. A single person's mouth typically harbors up to 100 bacterial species, while surveys of many people have found more than 700 different species, of which {approx}50% have never been cultivated. In typical metagenomics studies, the cells themselves are destroyed in the process of gathering sequence information, and thus the connection between genotype and phenotype is lost. A great deal of sequence information may be generated, but it is impossible to assign anymore » given sequence to a specific cell. We seek non-destructive, culture-independent means of gathering sequence information from selected individual cells from mixed populations. As a first step, we have developed a microfluidic device for concentrating and specifically labeling bacteria from a mixed population. Bacteria are electrophoretically concentrated against a photopolymerized membrane element, and then incubated with a specific fluorescent label, which can include antibodies as well as specific or non-specific nucleic acid stains. Unbound stain is washed away, and the labeled bacteria are released from the membrane. The stained cells can then be observed via epifluorescence microscopy, or counted via flow cytometry. We have tested our device with three representative bacteria from the human microbiome: E. coli (gut, Gram-negative), Lactobacillus acidophilus (mouth, Gram-positive), and Streptococcus mutans (mouth, Gram-positive), with results comparable to off-chip labeling techniques.« less
NASA Technical Reports Server (NTRS)
Metcalfe, A. G.; Bodenheimer, R. E.
1976-01-01
A parallel algorithm for counting the number of logic-l elements in a binary array or image developed during preliminary investigation of the Tse concept is described. The counting algorithm is implemented using a basic combinational structure. Modifications which improve the efficiency of the basic structure are also presented. A programmable Tse computer structure is proposed, along with a hardware control unit, Tse instruction set, and software program for execution of the counting algorithm. Finally, a comparison is made between the different structures in terms of their more important characteristics.
Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.
Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay
2016-04-09
Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.
Trumbo, D.E.
1959-02-10
A transistorized pulse-counting circuit adapted for use with nuclear radiation detecting detecting devices to provide a small, light weight portable counter is reported. The small size and low power requirements of the transistor are of particular value in this instance. The circuit provides an adjustable count scale with a single transistor which is triggered by the accumulated charge on a storage capacitor.
Electronic strain-level counter
NASA Technical Reports Server (NTRS)
Pitts, F. L.; Spencer, J. L. (Inventor)
1973-01-01
An electronic strain level counter for obtaining structural strain data on in-flight aircraft is described. The device counts the number of times the strain at a point on an aircraft structural member exceeds each of several preset levels. A dead band is provided at each level to prohibit the counting of small strain variations around a given preset level.
Sun, Jianjun; Liu, Li; Shen, Jiayin; Chen, Panpan; Lu, Hongzhou
2017-04-19
There are few studies focus on the factors underlying the late initiation of ART in China. We analyzed the trends in the median CD4 cell counts among different patient groups over time and the risk factors for the late initiation of ART in Shanghai, China. A retrospective cross-sectional survey was made in the Department of Infectious Disease of Shanghai Public Health Clinical Center which is a designated diagnosis and treatment center for HIV-positive patients in Shanghai during the period of January 1st, 2008--June 30th, 2014. Late ART initiation was defined as a CD4 cell count <200 cells/mm 3 or having a clinical AIDS diagnosis prior to ART initiation. Trends in the median CD4 cell count at ART initiation and the proportion of late ART initiation by year were evaluated using Spearman's correlations and Chi-squared methods, respectively. We used a logistic regression model to analyze the risk factors for late ART initiation. The related factors collected in the multivariate model were the patient's age, gender, infection routes and marital status. A total of 3796 patients were analyzed in this study, with a median baseline CD4 cell count of 205 cells/mm 3 [interquartile range: 75-287]. The median CD4 cell counts of patients initiating ART late increased from 76 cells/mm 3 in 2008 to 103 cells/mm 3 in 2014 (p < 0.001), and the proportion of late ART initiation decreased from 80% to 45% (p < 0.001). The risk factors for late ART initiation were male gender, heterosexual transmission and older age (>30 years) (p < 0.001). Notable improvements were made in the median CD4 cell count at ART initiation and the proportion of late ART initiation from 2008 to 2014. However, persons with high risk of HIV exposure who are male, older even heterosexual orientation should be given more opportunities to receive frequently screening, earlier diagnoses and timely treatment.
... white blood cells (WBC), and platelets. Blood count tests measure the number and types of cells in ... helps doctors check on your overall health. The tests can also help to diagnose diseases and conditions ...
Guo, Zhi-Ping; Wang, Tao; Xu, Lan-Ping; Zhang, Xiao-Hui; Wang, Yu; Huang, Xiao-Jun; Chang, Ying-Jun
2016-12-01
A second allogeneic hematopoietic stem-cell transplantation and donor lymphocyte infusion using cells from the same donor is a therapeutic option in the case of stem-cell graft failure or disease relapse, but little is known about the factors associated with the CD34 + cell yields from second donations. One-hundred healthy donors who underwent a second mobilization treatment and peripheral blood stem-cell (PBSC) collection were studied. For both mobilization processes, 5 µg of granulocyte colony-stimulating factor per kg per day was administered. The blood counts of the donors were monitored during the processes. The second donations from the same donors provided lower apheresis yields than did the initial collections. The number of CD34 + cells collected from normal donors after a second cycle of PBSC mobilization was associated with their steady-state lymphocyte counts and the intertransplantation interval. Female sex negatively affected the CD34 + cell yields. The cutoff value for the steady-state absolute lymphocyte count was 2.055 × 10 9 /L. To harvest greater numbers of CD34 + cells from second collections, male donors and those with intervals of longer than 9 months between donations should be selected. The lymphocyte counts prior to the first donations may predict the content of CD34 + cells in the allografts prepared using the second donations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Mast cells in systemic and cutaneous lupus erythematosus.
Kaczmarczyk-Sekuła, Karolina; Dyduch, Grzegorz; Kostański, Marcin; Wielowieyska-Szybińska, Dorota; Szpor, Joanna; Białas, Magdalena; Okoń, Krzysztof
2015-12-01
Mast cells (MCs) are known to be regulators of inflammation and immunity, due to the released mediators and expressed cell surface molecules. Lupus erythematosus (LE) is a group of diseases which can be systemic or limited to the skin. Due to the fact that cytokines and chemokines produced by inflammatory cells contribute to the pathogenesis of LE, we quantified the number of mast cells present in the skin. The aim of the study was to compare the chymase-positive and tryptase-positive mast cell counts within skin biopsies from patients with systemic lupus erythematosus (SLE), discoid lupus erythematosus (DLE) and subacute cutaneous lupus erythematosus (SCLE). The material consisted of 45 skin biopsies: 6 with SLE, 34 with DLE and 5 with SCLE. Chymase- and tryptase-positive cells were stained by immunohistochemistry and counted. The mean count of chymase-positive mast cells was 85.14 hpf for the whole group, 35.83 for SLE, 88.48 for DLE and 121.6 for SCLE. The mean count of tryptase-positive cells was 120.05 hpf for the entire group, 59.17 for SLE, 126.42 for DLE and 149.8 for SCLE. The differences between groups were significant for chymase- and tryptase-positive cells.
Lopez, B L; Griswold, S K; Navek, A; Urbanski, L
1996-08-01
To assess the usefulness of the complete blood count (CBC) and the reticulocyte count in the evaluation of adult patients with acute vasoocclusive sickle-cell crisis (SCC) presenting to the ED. A 2-part study was performed. Part 1 was retrospective chart review of patients with a sole ED diagnosis of acute SCC. Part 2 was a prospective evaluation of consecutive patients presenting in SCC. In both parts of the study, patients with coexisting acute disease were excluded. The remaining patients were divided into 2 groups: admitted and released. The mean values for white blood cell (WBC) count, hemoglobin (Hb) level, and reticulocyte count were compared. In Part 2, the change (delta) from the patient's baseline in WBC count, Hb level, and reticulocyte count also was determined. Data were analyzed by 2-tailed Student's t-test. Part 1: There was no difference between the admitted (n = 33) and the released (n = 86) groups in mean WBC count (p = 0.10), Hb level (p = 0.25), or reticulocyte count (p = 0.08). Part 2: There was no difference between the admitted (n = 44) and the released (n = 160) groups in mean Hb level (p = 0.88), reticulocyte count (p = 0.47), delta Hb level (p = 0.88), and delta reticulocyte count (p = 0.76). There was a difference in mean WBC counts (15.8 +/- 4.9 x 10(9)/L admitted vs 12.8 +/- 4.9 x 10(9)/L released, p = 0.003) and delta WBC counts (5.1 +/- 4.6 x 10(9)/L admitted vs 1.8 +/- 4.6 x 10(9)/L released, p < 0.002). Determination of the Hb level and the reticulocyte count do not appear useful in the evaluation of acute SCC in the ED. Admission decisions appear associated with elevations in the WBC count. Further study is required to determine the true value of the WBC count in such decisions.
2014-12-11
and 1 mm depth. Bacterial culture and cell count determination Bacterial species of Acinetobacter baumannii (A. baumannii, ST-3), Escherichia coli...remove all broth components followed by a final resuspension of the pellet in ddH2O back to 1 OD. Cell count was determined by plating the 10 4 , 10 3...10 2 and 10 1 cell dilutions on TSB Nutrient Agar media. Colony forming units (CFU) were counted the following day to confirm bacterial species
Curtin, John; Cormican, Martin; Fleming, Gerard; Keelehan, John; Colleran, Emer
2003-01-01
Central venous catheter (CVC)-related infection (CVC-RI) is a common complication of CVC use. The most common etiological agents of CVC-RI are gram-positive organisms, in particular, staphylococci. An in vitro model for the formation of biofilms by Staphylococcus epidermidis ATCC 35984 on polyurethane coupons in a modified Robbins device was established. Biofilm formation was confirmed by electron microscopy and was quantified by determination of viable counts. Mueller-Hinton broth was replaced with sterile physiological saline (control) or a solution of vancomycin (10 mg/ml), gentamicin (10 mg/ml), linezolid (2 mg/ml), or eperezolid (4 mg/ml). Viable counts were performed with the coupons after exposure to antimicrobials for periods of 24, 72, 168, and 240 h. The mean viable count per coupon following establishment of the biofilm was 4.6 × 108 CFU/coupon, and that after 14 days of exposure to physiological saline was 2.5 × 107 CFU/coupon. On exposure to vancomycin (10 mg/ml), the mean counts were 2.5 × 107 CFU/coupon at 24 h, 4.3 × 106 CFU/coupon at 72 h, 1.4 × 105 CFU/coupon at 168 h, and undetectable at 240 h. With gentamicin (10 mg/ml) the mean counts were 2.7 × 107 CFU/coupon at 24 h, 3.7 × 106 CFU/coupon at 72 h, 8.4 × 106 CFU/coupon at 168 h, and 6.5 × 106 CFU/coupon at 240 h. With linezolid at 2 mg/ml the mean counts were 7.1 × 105 CFU/coupon at 24 h and not detectable at 72, 168, and 240 h. With eperezolid (4 mg/ml) no viable cells were recovered after 168 h. These data suggest that linezolid (2 mg/ml) and eperezolid (4 mg/ml) achieve eradication of S. epidermidis biofilms more rapidly than vancomycin (10 mg/ml) and gentamicin (10 mg/ml). PMID:14506022
Lim, Jeong-Ae; Oh, Chung-Sik; Yoon, Tae-Gyoon; Lee, Ji Yeon; Lee, Seung-Hyun; Yoo, Young-Bum; Yang, Jung-Hyun; Kim, Seong-Hyop
2018-02-07
To clarify the effect of anaesthetic agents on cancer immunity, we evaluated the effects of propofol and sevoflurane on natural killer (NK) cell, cytotoxic T lymphocyte (CTL) counts and apoptosis rate in breast cancer and immune cells co-cultures from patients who underwent breast cancer surgery. Venous blood samples were collected after inducing anaesthesia and at 1 and 24 h postoperatively in patients who had undergone breast cancer surgery. The patients were allocated randomly to the propofol- or sevoflurane-based anaesthesia groups. We counted and detected apoptosis in cancer cell, NK cell and CTL of patients with breast cancer by co-culture with a breast cancer cell line in both groups. We also evaluated changes in the cytokines tumour necrosis factor-alpha, interleukin (IL)-6 and IL-10 during the perioperative period. Forty-four patients were included in the final analysis. No difference in NK cell count, CTL count or apoptosis rate was detected between the groups. Furthermore, the number of breast cancer cells undergoing apoptosis in the breast cancer cell co-cultures was not different between the groups. No changes in cytokines were detected between the groups. Although basic science studies have suggested the potential benefits of propofol over a volatile agent during cancer surgery, propofol was not superior to sevoflurane, on the aspects of NK and CTL cells counts with apoptosis rate including breast cancer cell, during anaesthesia for breast cancer surgery in a clinical environment. NCT02758249 on February 26, 2016.
Comparison of candidate materials for a synthetic osteo-odonto keratoprosthesis device.
Tan, Xiao Wei; Perera, A Promoda P; Tan, Anna; Tan, Donald; Khor, K A; Beuerman, Roger W; Mehta, Jodhbir S
2011-01-05
Osteo-odonto keratoprosthesis is one of the most successful forms of keratoprosthesis surgery for end-stage corneal and ocular surface disease. There is a lack of detailed comparison studies on the biocompatibilities of different materials used in keratoprosthesis. The aim of this investigation was to compare synthetic bioinert materials used for keratoprosthesis surgery with hydroxyapatite (HA) as a reference. Test materials were sintered titanium oxide (TiO(2)), aluminum oxide (Al(2)O(3)), and yttria-stabilized zirconia (YSZ) with density >95%. Bacterial adhesion on the substrates was evaluated using scanning electron microscopy and the spread plate method. Surface properties of the implant discs were scanned using optical microscopy. Human keratocyte attachment and proliferation rates were assessed by cell counting and MTT assay at different time points. Morphologic analysis and immunoblotting were used to evaluate focal adhesion formation, whereas cell adhesion force was measured with a multimode atomic force microscope. The authors found that bacterial adhesion on the TiO(2), Al(2)O(3), and YSZ surfaces were lower than that on HA substrates. TiO(2) significantly promoted keratocyte proliferation and viability compared with HA, Al(2)O(3,) and YSZ. Immunofluorescent imaging analyses, immunoblotting, and atomic force microscope measurement revealed that TiO(2) surfaces enhanced cell spreading and cell adhesion compared with HA and Al(2)O(3). TiO(2) is the most suitable replacement candidate for use as skirt material because it enhanced cell functions and reduced bacterial adhesion. This would, in turn, enhance tissue integration and reduce device failure rates during keratoprosthesis surgery.
Vernon, Lance T.; Demko, Catherine A.; Babineau, Denise C.; Wang, Xuelei; Toossi, Zahra; Weinberg, Aaron; Rodriguez, Benigno
2013-01-01
Background The contribution of HIV-infection to periodontal disease (PD) is poorly understood. We proposed that immunological markers would be associated with improved clinical measures of PD. Methods We performed a longitudinal cohort study of HIV-infected adults who had started highly active antiretroviral therapy (HAART) <2 years. PD was characterized clinically as the percent of teeth with ≥1 site with periodontal probing depth (PPD) ≥5.0mm, recession (REC) >0mm, clinical attachment level (CAL) ≥4.0mm, and bleeding on probing (BOP) at ≥4 sites/tooth and microbiologically as specific periodontopathogen concentration. Linear mixed-effects models were used to assess the associations between immune function and PD. Results Forty (40) subjects with median 2.7 months on HAART and median nadir CD4+ T-cell count of 212 cells/μl completed a median 3 visits. Over 24 months, CD4+ T-cell count increased by a mean 173 cells/µl (p<0.001) and HIV RNA decreased by 0.5 log10 copies/ml (p<0.001); concurrently, PPD, CAL and BOP decreased by a mean 11.7%, 12.1%, and 14.7% respectively (all p<0.001). Lower nadir CD4+ T-cell count was associated with worse baseline REC (-6.72%; p=0.04) and CAL (9.06%; p<0.001). Further, lower nadir CD4+ T-cell count was associated with a greater relative longitudinal improvement in PPD in subjects with higher baseline levels of Porphyromonas gingivalis (p=0.027), and BOP in subjects with higher baseline levels of Porphyromonas gingivalis or Treponema denticola (p=0.001 and p=0.006 respectively). Longitudinal changes from baseline in CD4+ T-cell count and level of HIV RNA were not independently associated with longitudinal changes in any clinical markers of PD. Conclusion Degree of immunosuppression was associated with baseline gingival recession. After HAART initiation, measures of active PD improved most in those with lower nadir CD4+ T-cell counts and higher baseline levels of specific periodontopathogens. Nadir CD4+ T-cell count differentially influences periodontal disease both before and after HAART in HIV-infected adults. PMID:24146949
Thromboresistance Characterization of Extruded Nitric Oxide-Releasing Silicone Catheters
Amoako, Kagya A.; Archangeli, Christopher; Handa, Hitesh; Major, Terry; Meyerhoff, Mark E.; Annich, Gail M.; Bartlett, Robert H.
2013-01-01
Intravascular catheters used in clinical practice can activate platelets, leading to thrombus formation and stagnation of blood flow. Nitric oxide (NO)-releasing polymers have been shown previously to reduce clot formation on a number of blood contacting devices. In this work, trilaminar NO-releasing silicone catheters were fabricated and tested for their thrombogenicity. All catheters had specifications of L = 6 cm, inner diameter = 21 gauge (0.0723 cm), outer diameter = 12 gauge (0.2052 cm), and NO-releasing layer thickness = 200 ± 11 μm. Control and NO-releasing catheters were characterized in vitro for their NO flux and NO release duration by gas phase chemiluminescence measurements. The catheters were then implanted in the right and left internal jugular veins of (N = 6 and average weight = 3 kg) adult male rabbits for 4 hours thrombogenicity testing. Platelet counts and function, methemoglobin (metHb), hemoglobin (Hb), and white cell counts and functional time (defined as patency time of catheter) were monitored as measured outcomes. Nitric oxide-releasing catheters (N = 6) maintained an average flux above (2 ± 0.5) × 10−10 mol/min/cm2 for more than 24 hours, whereas controls showed no NO release. Methemoglobin, Hb, white cell, and platelet counts and platelet function at 4 hours were not significantly different from baseline (α = 0.05). However, clots on controls were visibly larger and prevented blood draws at a significantly (p < 0.05) earlier time (2.3 ± 0.7 hours) into the experiment, whereas all NO-releasing catheters survived the entire 4 hours test period. Results indicate that catheter NO flux levels attenuated thrombus formation in a short-term animal model. PMID:22395119
Pettipher, Graham L.; Mansell, Roderick; McKinnon, Charles H.; Cousins, Christina M.
1980-01-01
Membrane filtration and epifluorescent microscopy were used for the direct enumeration of bacteria in raw milk. Somatic cells were lysed by treatment with trypsin and Triton X-100 so that 2 ml of milk containing up to 5 × 106 somatic cells/ml could be filtered. The majority of the bacteria (ca. 80%) remained intact and were concentrated on the membrane. After being stained with acridine organe, the bacteria fluoresced under ultraviolet light and could easily be counted. The clump count of orange fluorescing cells on the membrane correlated well (r = 0.91) with the corresponding plate count for farm, tanker, and silo milks. Differences between counts obtained by different operators and between the membrane clump count and plate count were not significant. The technique is rapid, taking less than 25 min, inexpensive, costing less than 50 cents per sample, and is suitable for milks containing 5 × 103 to 5 × 108 bacteria per ml. Images PMID:16345515
A novel conduit-based coaptation device for primary nerve repair.
Bamba, Ravinder; Riley, D Colton; Kelm, Nathaniel D; Cardwell, Nancy; Pollins, Alonda C; Afshari, Ashkan; Nguyen, Lyly; Dortch, Richard D; Thayer, Wesley P
2018-06-01
Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.
Hip Synovial Fluid Cell Counts in Children From a Lyme Disease Endemic Area.
Dart, Arianna H; Michelson, Kenneth A; Aronson, Paul L; Garro, Aris C; Lee, Thomas J; Glerum, Kimberly M; Nigrovic, Peter A; Kocher, Mininder S; Bachur, Richard G; Nigrovic, Lise E
2018-05-01
Patients with septic hip arthritis require surgical drainage, but they can be difficult to distinguish from patients with Lyme arthritis. The ability of synovial fluid white blood cell (WBC) counts to help discriminate between septic and Lyme arthritis of the hip has not been investigated. We assembled a retrospective cohort of patients ≤21 years of age with hip monoarticular arthritis and a synovial fluid culture obtained who presented to 1 of 3 emergency departments located in Lyme disease endemic areas. Septic arthritis was defined as a positive synovial fluid culture result or synovial fluid pleocytosis (WBC count ≥50 000 cells per µL) with a positive blood culture result. Lyme arthritis was defined as positive 2-tiered Lyme disease serology results and negative synovial fluid bacterial culture results. All other patients were classified as having other arthritis. We compared median synovial fluid WBC counts by arthritis type. Of the 238 eligible patients, 26 (11%) had septic arthritis, 32 (13%) had Lyme arthritis, and 180 (76%) had other arthritis. Patients with septic arthritis had a higher median synovial fluid WBC count (126 130 cells per µL; interquartile range 83 303-209 332 cells per µL) than patients with Lyme arthritis (53 955 cells per µL; interquartile range 33 789-73 375 cells per µL). Eighteen patients (56%) with Lyme arthritis had synovial fluid WBC counts ≥50 000 cells per µL. Of the 94 patients who underwent surgical drainage, 13 were later diagnosed with Lyme arthritis. In Lyme disease endemic areas, synovial fluid WBC counts cannot always help differentiate septic from Lyme arthritis. Rapid Lyme diagnostics could help avoid unnecessary operative procedures in patients with Lyme arthritis. Copyright © 2018 by the American Academy of Pediatrics.
Neonatal nucleated red blood cells in infants of overweight and obese mothers.
Sheffer-Mimouni, Galit; Mimouni, Francis B; Dollberg, Shaul; Mandel, Dror; Deutsch, Varda; Littner, Yoav
2007-06-01
The perinatal outcome of the infant of obese mother is adversely affected and in theory, may involve fetal hypoxia. We hypothesized that an index of fetal hypoxia, the neonatal nucleated red blood cell (NRBC) count, is elevated in infants of overweight and obese mothers. Absolute NRBC counts taken during the first 12 hours of life in 41 infants of overweight and obese mothers were compared to 28 controls. Maternal body mass index and infant birthweight were significantly higher in the overweight and obese group (P < 0.01). Hematocrit, corrected white blood cell and lymphocyte counts did not differ between groups. The absolute NRBC count was higher (P = 0.01), and the platelet count lower (P = 0.05) in infants of overweight and obese mothers than in controls. In stepwise regression analysis, the absolute NRBC count in infants of overweight and obese mothers remained significantly higher even after taking into account birthweight or gestational age and Apgar scores (P < 0.02). Infants of overweight and obese mothers have increased nucleated red blood cells at birth compared with controls. We speculate that even apparently healthy fetuses of overweight and obese mothers are exposed to a subtle hypoxemic environment.
Design of Low-Complexity and High-Speed Coplanar Four-Bit Ripple Carry Adder in QCA Technology
NASA Astrophysics Data System (ADS)
Balali, Moslem; Rezai, Abdalhossein
2018-07-01
Quantum-dot Cellular Automata (QCA) technology is a suitable technology to replace CMOS technology due to low-power consumption, high-speed and high-density devices. Full adder has an important role in the digital circuit design. This paper presents and evaluates a novel single-layer four-bit QCA Ripple Carry Adder (RCA) circuit. The developed four-bit QCA RCA circuit is based on novel QCA full adder circuit. The developed circuits are simulated using QCADesigner tool version 2.0.3. The simulation results show that the developed circuits have advantages in comparison with existing single-layer and multilayer circuits in terms of cell count, area occupation and circuit latency.
Design of Low-Complexity and High-Speed Coplanar Four-Bit Ripple Carry Adder in QCA Technology
NASA Astrophysics Data System (ADS)
Balali, Moslem; Rezai, Abdalhossein
2018-03-01
Quantum-dot Cellular Automata (QCA) technology is a suitable technology to replace CMOS technology due to low-power consumption, high-speed and high-density devices. Full adder has an important role in the digital circuit design. This paper presents and evaluates a novel single-layer four-bit QCA Ripple Carry Adder (RCA) circuit. The developed four-bit QCA RCA circuit is based on novel QCA full adder circuit. The developed circuits are simulated using QCADesigner tool version 2.0.3. The simulation results show that the developed circuits have advantages in comparison with existing single-layer and multilayer circuits in terms of cell count, area occupation and circuit latency.
The prognostic value of natural killer cell infiltration in resected pulmonary adenocarcinoma.
Takanami, I; Takeuchi, K; Giga, M
2001-06-01
Natural cytotoxicity caused by mediated natural killer cells is believed to play an important role in host-cancer defense mechanisms. Immunohistochemically, we have detected natural killer cells in tissue specimens from patients with pulmonary adenocarcinoma and have assessed their clinical characteristics. Using the monoclonal antibody for CD57 specific marker for natural killer cells, we quantified natural killer cell infiltration in 150 patients with pulmonary adenocarcinoma who underwent curative tumor resection to investigate the relationship between natural killer cell counts and clinicopathologic factors and prognosis. The natural killer cell count was significantly related to the regulation of tumor progression, involving T classification, N classification, and stage (P =.01 for T classification or stage; P =.02 for N classification). A significant difference in the rate of patient survival was detected between those patients whose tumors had either high or low natural killer cell counts in both the overall and stage I groups (P =.0002 for the overall group; P =.049 for the stage I group). These data indicate that natural killer infiltration may contribute to the regulation of tumor progression and that the natural killer cell count can serve as a useful prognostic marker in overall and stage I pulmonary adenocarcinoma.
Studies on the erythron and the ferrokinetic responses in beagles adapted to hypergravity
NASA Technical Reports Server (NTRS)
Beckman, D. A.; Evans, J. W.; Oyama, J.
1978-01-01
Red cell survival, ferrokinetics, and hematologic parameters were investigated in beagle dogs exposed to chronic hypergravity (2.6 Gx). Ineffective erythropoiesis, red cell mass, plasma volume, and Cr-51-elution were significantly increased; maximum Fe-59 incorporation was decreased; and there was no change in the mean erythrocyte life span following autologous injection of Cr-51-labeled red cells and Fe-59-labeled transferrin. Red cell count, F(cells), total body hemoglobin (Hb), susceptability to osmotic lysis, and differential reticulocyte count were increased. White blood cell count, venous blood %Hb, mean cell volume, mean cell Hb, mean cell Hb concentration, and serum iron were decreased. No changes were observed for body mass, mg Fe per g Hb, iron binding capacity, percent saturation of iron carrying capacity, or the electrophoretic mobility of purified Hb. This study indicated that chronic exposure to hypergravity induced changes in red cell size, volume, total mass, and membrane permeability.
Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong; Kim, Hee Chan
2017-01-01
The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method as an automated white blood cell differential count system.
Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong
2017-01-01
The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method as an automated white blood cell differential count system. PMID:29228051
Rallón, Norma; Sempere-Ortells, José M; Soriano, Vincent; Benito, José M
2013-11-01
It is unclear to what extent T cell reconstitution may be possible in HIV-1-infected individuals on continuous successful highly active antiretroviral therapy (HAART). Herein, we analysed distinct phenotypic markers of immune recovery in patients with undetectable viraemia for 8 years, taking as reference untreated patients and healthy controls. Seventy-two subjects were examined: 28 HIV-1+ patients on successful long-term HAART, 24 HIV-1+ untreated viraemic patients and 20 age-matched healthy controls. Analysis of naive and memory CD4 and CD8 T cells was combined with measurements of activation status (expression of CD38) and with thymic function (expression of CD31). Statistical significance was determined by non-parametric tests. After long-term HAART, the majority of parameters were normalized compared with age-matched control values, including T cell activation and thymic function. However, absolute counts of naive and central memory CD4 T cells remained below normal levels. The only parameters significantly associated with CD4 counts at the end of follow-up were the pre-HAART CD4 count ( β ± SD = 0.54 ± 0.16, P = 0.003) and the level of CD4 central memory cells at the end of follow-up (β ± SD = 1.18 ± 0.23, P < 0.0001). Only patients starting HAART with CD4 counts >350 cells/mm(3) reached a complete normalization of CD4 counts. Even after long-term successful HAART, complete CD4 restoration may be attainable only in patients starting therapy with moderately high CD4 counts, prompting early initiation of antiretroviral therapy. Incomplete CD4 restoration may be associated with a defective restoration of central memory CD4 T cells, a cell subset with a pivotal role in T cell homeostasis.
Rainard, P; Ducelliez, M; Poutrel, B
1990-01-01
Quarter foremilk samples were taken at 2-3 weekly intervals for several years in an experimental herd comprising about 45 cows. The samples were submitted to bacteriological analysis and somatic cell counting. The most prevalent quarter infections from 1982 to 1988 were by coagulase-negative staphylococci (15-20% of all the quarters sampled). Most of these (75.6%) persisted until drying-off. Dry cow therapy eliminated 86.5% of these infections. Comparison of udder quarters within cows, involving 775 samples from pairs of non-infected quarters and quarters infected by coagulase-negative staphylococci, yielded geometric means of somatic cell counts of 210,000 and 420,000 cells/ml, respectively. The correlation (r = 0.87) between the herd bulk milk somatic cell count (SCC) and its estimation from the quarter milk somatic cell count performed on the same day allowed us to evaluate the contribution of the different categories of quarters, according to their infection status, to the herd bulk milk SCC. Quarters infected by a major pathogen (8.5% of samples) gave rise to 46.6% of the total number of cells, while quarters infected by coagulase-negative staphylococci (17.8% of samples) gave rise to 18.1%. Although coagulase-negative staphylococci represented only a secondary source of somatic cells as compared to major pathogens, they were not a negligible source considering the threshold of 300,000 somatic cells advocated for herd milk of good quality.
HIV Patients Drop Out in Indonesia: Associated Factors and Potential Productivity Loss.
Siregar, Adiatma Ym; Pitriyan, Pipit; Wisaksana, Rudi
2016-07-01
this study reported various factors associated with a higher probability of HIV patients drop out, and potential productivity loss due to HIV patients drop out. we analyzed data of 658 HIV patients from a database in a main referral hospital in Bandung city, West Java, Indonesia from 2007 to 2013. First, we utilized probit regression analysis and included, among others, the following variables: patients' status (active or drop out), CD4 cell count, TB and opportunistic infection (OI), work status, sex, history of injecting drugs, and support from family and peers. Second, we used the drop out data from our database and CD 4 cell count decline rate from another study to estimate the productivity loss due to HIV patients drop out. lower CD4 cell count was associated with a higher probability of drop out. Support from family/peers, living with family, and diagnosed with TB were associated with lower probability of drop out. The productivity loss at national level due to treatment drop out (consequently, due to CD4 cell count decline) can reach US$365 million (using average wage). first, as lower CD 4 cell count was associated with higher probability of drop out, we recommend (to optimize) early ARV initiation at a higher CD 4 cell count, involving scaling up HIV service at the community level. Second, family/peer support should be further emphasized to further ensure treatment success. Third, dropping out from ART will result in a relatively large productivity loss.
Criado, Ignacio; Muñoz-Criado, Santiago; Rodríguez-Caballero, Arancha; Nieto, Wendy G.; Romero, Alfonso; Fernández-Navarro, Paulino; Alcoceba, Miguel; Contreras, Teresa; González, Marcos; Orfao, Alberto; Almeida, Julia
2017-01-01
Patients diagnosed with chronic lymphocytic leukemia (CLL) display a high incidence of infections due to an associated immunodeficiency that includes hypogammaglobulinemia. A higher risk of infections has also been recently reported for high-count monoclonal B-cell lymphocytosis, while no information is available in low-count monoclonal B-cell lymphocytosis. Here, we evaluated the status of the humoral immune system in patients with chronic lymphocytic leukemia (n=58), as well as in low- (n=71) and high- (n=29) count monoclonal B-cell lymphocytosis versus healthy donors (n=91). Total free plasma immunoglobulin titers and specific levels of antibodies against cytomegalovirus, Epstein-Barr virus, influenza and S.pneumoniae were measured by nephelometry and ELISA-based techniques, respectively. Overall, our results show that both CLL and high-count monoclonal B-cell lymphocytosis patients, but not low-count monoclonal B-cell lymphocytosis subjects, present with relatively high levels of antibodies specific for the latent viruses investigated, associated with progressively lower levels of S.pneumoniae-specific immunoglobulins. These findings probably reflect asymptomatic chronic reactivation of humoral immune responses against host viruses associated with expanded virus-specific antibody levels and progressively decreased protection against other micro-organisms, denoting a severe humoral immunodeficiency state not reflected by the overall plasma immunoglobulin levels. Alternatively, these results could reflect a potential role of ubiquitous viruses in the pathogenesis of the disease. Further analyses are necessary to establish the relevance of such asymptomatic humoral immune responses against host viruses in the expansion of the tumor B-cell clone and progression from monoclonal B-cell lymphocytosis to CLL. PMID:28385786
Wartenberg, Martin; Zlobec, Inti; Perren, Aurel; Koelzer, Viktor Hendrik; Gloor, Beat; Lugli, Alessandro; Eva, Karamitopoulou
2015-01-01
Here we explore the role of the interplay between host immune response and epithelial-mesenchymal-transition (EMT)-Type tumor-budding on the outcome of pancreatic adenocarcinoma (PDAC). CD4+, CD8+, and FOXP3+T-cells as well as iNOS+ (M1) and CD163+-macrophages (M2) were assessed on multipunch tissue-microarrays containing 120 well-characterized PDACs, precursor lesions (PanINs) and corresponding normal tissue. Counts were normalized for the percentage of tumor/spot and associated with the clinico-pathological features, including peritumoral (PTB) and intratumoral (ITB) EMT-Type tumor-budding and outcome. Increased FOXP3+T-cell-counts and CD163-macrophages and decreased CD8+T-cell-counts were observed in PDACs compared with normal tissues and PanINs (p < 0.0001). Increased peritumoral FOXP3+T-cell-counts correlated significantly with venous invasion, distant metastasis, R1-status, high-grade ITB, PTB and independently with reduced survival. Increased intratumoral FOXP3+T-cells correlated with lymphatic invasion, N1-stage, PTB and marginally with adverse outcome. High peritumoral CD163-counts correlated with venous invasion, PTB and ITB. High intratumoral CD163-counts correlated with higher T-stage and PTB. PDAC-microenvironment displays a tumor-favoring immune-cell composition especially in the immediate environment of the tumor-buds that promotes further growth and indicates a close interaction of the immune response with the EMT-process. Increased peritumoral FOXP3+T-cell density is identified as an independent adverse prognostic factor in PDAC. Patients with phenotypically aggressive PDACs may profit from targeted immunotherapy against FOXP3. PMID:25669968
Sasagawa, Yohei; Danno, Hiroki; Takada, Hitomi; Ebisawa, Masashi; Tanaka, Kaori; Hayashi, Tetsutaro; Kurisaki, Akira; Nikaido, Itoshi
2018-03-09
High-throughput single-cell RNA-seq methods assign limited unique molecular identifier (UMI) counts as gene expression values to single cells from shallow sequence reads and detect limited gene counts. We thus developed a high-throughput single-cell RNA-seq method, Quartz-Seq2, to overcome these issues. Our improvements in the reaction steps make it possible to effectively convert initial reads to UMI counts, at a rate of 30-50%, and detect more genes. To demonstrate the power of Quartz-Seq2, we analyzed approximately 10,000 transcriptomes from in vitro embryonic stem cells and an in vivo stromal vascular fraction with a limited number of reads.
Independent prognostic value of eosinophil and mast cell infiltration in colorectal cancer tissue.
Nielsen, H J; Hansen, U; Christensen, I J; Reimert, C M; Brünner, N; Moesgaard, F
1999-12-01
Overall peritumoural inflammatory cell infiltration is a prognostic variable in solid tumours, but the survival-related impact of the individual cell types within the infiltrate has still not been fully evaluated and compared with the conventional disease classification. In the present study, the prognostic value of individual white cell counts in the peritumoural inflammatory infiltrate in colorectal cancer was assessed. Intra-operative tumour tissue samples from 584 patients undergoing elective surgery for colorectal cancer were included. None of the patients received pre- or post-operative adjuvant chemotherapy. Tissue blocks were cut from the periphery of the tumours and embedded in paraffin. All blocks included both tumour tissue and normal bowel tissue. Serial sections of 4 microm were analysed for tumour tissue inflammatory cell infiltration using a computer- and video-assisted microscope, which allowed semi-automated quantification of cells within a fixed area. Total white cells and individual counts of eosinophils, neutrophils, mast cells, lymphocytes, and plasma cells were evaluated in every tumour specimen. Stratification into four groups with similar numbers of events was used to dichotomize the cell counts with respect to survival. The median observation period was 61 (49-75) months. In a multivariate analysis including Dukes' stage, gender, age, peri-operative blood transfusion, tumour location, and counts of specific inflammatory cells, only advanced Dukes' stage ( p< 0.0001), high age ( p=0.0003), and tumour location in the rectum predicted poor survival, while high counts of eosinophils ( p=0.006) and mast cells ( p=0.02) predicted good survival. Tumour-associated eosinophilia and mastocytosis appear to be independent prognostic variables in colorectal cancer. Future studies should investigate the potential biological role of tumour tissue eosinophils and mast cells in the modulation of tumour growth. Copyright 1999 John Wiley & Sons, Ltd.
Sarwar, Zahid Mahmood; Ijaz, Mamuna; Sabri, Muhammad Altaf; Yousaf, Hasnain; Mohsan, Muhammad
2018-06-01
Red cotton bug, Dysdercus koenigii (Hemiptera: Pyrrhocoridae), has become the major insect pest of various crops, including cotton, and thereby reducing the yield qualitatively and quantitatively and synthetic insecticides belonging to different groups are the major control agents for such insect pests. A laboratory experiment was carried out to evaluate the effect of different conventional insecticides, i.e., imidacloprid, deltamethrin, lambda cyhalothrin, gamma cyhalothrin and cyfluthirn on haemocytes of D. koenigii. The individuals were exposed to insecticides separately and data was recorded after 30 and 60 min of the exposure. The findings of current study depicted chlorpyrifos to be more effective and significant alterations in total haemocyte counts and differential haemocyte counts were observed in the cyfluthirn treated D. koenigii. In addition to this, cell structure was also disrupted as an immune response. Similar studies would also be helpful to understand the defence mechanisms of insects against the xenobiotics which will help to device efficient management tools for D. koenigii.
Impact of nitinol stent surface processing on in-vivo nickel release and biological response.
Nagaraja, Srinidhi; Sullivan, Stacey J L; Stafford, Philip R; Lucas, Anne D; Malkin, Elon
2018-05-01
Although nitinol is widely used in percutaneous cardiovascular interventions, a causal relationship between nickel released from implanted cardiovascular devices and adverse systemic or local biological responses has not been established. The objective of this study was to investigate the relationship between nitinol surface processing, in-vivo nickel release, and biocompatibility. Nitinol stents manufactured using select surface treatments were implanted into the iliac arteries of minipigs for 6 months. Clinical chemistry profile, complete blood count, serum and urine nickel analyses were performed periodically during the implantation period. After explant, stented arteries were either digested and analyzed for local nickel concentration or fixed and sectioned for histopathological analysis of stenosis and inflammation within the artery. The results indicated that markers for liver and kidney function were not different than baseline values throughout 180 days of implantation regardless of surface finish. In addition, white blood cell, red blood cell, and platelet counts were similar to baseline values for all surface finishes. Systemic nickel concentrations in serum and urine were not significantly different between processing groups and comparable to baseline values during 180 days of implantation. However, stents with non-optimized surface finishing had significantly greater nickel levels in the surrounding artery compared to polished stents. These stents had increased stenosis with potential for local inflammation compared to polished stents. These findings demonstrate that proper polishing of nitinol surfaces can reduce in-vivo nickel release locally, which may aid in minimizing adverse inflammatory reactions and restenosis. Nitinol is a commonly used material in cardiovascular medical devices. However, relationships between nitinol surface finishing, in-vivo metal ion release, and adverse biological responses have yet to be established. We addressed this knowledge gap by implanting single and overlapped nitinol stents with different surface finishes to assess systemic impact on minipigs (i.e. serum and urine nickel levels, liver and kidney function, immune and blood count) over the 6 month implantation period. In addition, nickel levels and histopathology in stented arteries were analyzed on explant to determine relationships between surface processing and local adverse tissue reactions. The findings presented here highlight the importance of surface processing on in-vivo nickel release and subsequent impact on local biological response for nitinol implants. Published by Elsevier Ltd.
Jackson, Benjamin M; Polglaze, Ted; Dawson, Brian; King, Trish; Peeling, Peter
2018-02-21
To compare data from conventional GPS and new GNSS-enabled tracking devices, and to examine the inter-unit reliability of GNSS devices. Inter-device differences between 10 Hz GPS and GNSS devices were examined during laps (n=40) of a simulated game circuit (SGC) and during elite hockey matches (n=21); GNSS inter-unit reliability was also examined during the SGC laps. Differences in distance values and measures in three velocity categories (low <3 m.s -1 ; moderate 3-5 m.s -1 ; high >5 m.s -1 ) and acceleration/deceleration counts (>1.46 m.s -2 and < -1.46 m.s -2 ) were examined using one-way ANOVA. Inter-unit GNSS reliability was examined using the coefficient of variation (CV) and intra-class correlation coefficient (ICC). Inter-device differences (P <0.05) were found for measures of peak deceleration, low-speed distance, % total distance at low speed, and deceleration count during the SGC, and for all measures except total distance and low-speed distance during hockey matches. Inter-unit (GNSS) differences (P <0.05) were not found. The CV was below 5% for total distance, average and peak speeds and distance and % total distance of low-speed running. The GNSS devices had a lower HDoP score than GPS devices in all conditions. These findings suggest that GNSS devices may be more sensitive than GPS in quantifying the physical demands of team sport movements, but further study into the accuracy of GNSS devices is required.
NASA Technical Reports Server (NTRS)
Prochzaka, Ivan; Kodat, Jan; Blazej, Josef; Sun, Xiaoli (Editor)
2015-01-01
We are reporting on a design, construction and performance of photon-counting detector packages based on silicon avalanche photodiodes. These photon-counting devices have been optimized for extremely high stability of their detection delay. The detectors have been designed for future applications in fundamental metrology and optical time transfer in space. The detectors have been qualified for operation in space missions. The exceptional radiation tolerance of the detection chip itself and of all critical components of a detector package has been verified in a series of experiments.
NASA Astrophysics Data System (ADS)
Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.
2013-04-01
High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.
The CAOS camera platform: ushering in a paradigm change in extreme dynamic range imager design
NASA Astrophysics Data System (ADS)
Riza, Nabeel A.
2017-02-01
Multi-pixel imaging devices such as CCD, CMOS and Focal Plane Array (FPA) photo-sensors dominate the imaging world. These Photo-Detector Array (PDA) devices certainly have their merits including increasingly high pixel counts and shrinking pixel sizes, nevertheless, they are also being hampered by limitations in instantaneous dynamic range, inter-pixel crosstalk, quantum full well capacity, signal-to-noise ratio, sensitivity, spectral flexibility, and in some cases, imager response time. Recently invented is the Coded Access Optical Sensor (CAOS) Camera platform that works in unison with current Photo-Detector Array (PDA) technology to counter fundamental limitations of PDA-based imagers while providing high enough imaging spatial resolution and pixel counts. Using for example the Texas Instruments (TI) Digital Micromirror Device (DMD) to engineer the CAOS camera platform, ushered in is a paradigm change in advanced imager design, particularly for extreme dynamic range applications.
Electrochemical magneto-actuated biosensor for CD4 count in AIDS diagnosis and monitoring.
Carinelli, S; Xufré Ballesteros, C; Martí, M; Alegret, S; Pividori, M I
2015-12-15
The counting of CD4(+) T lymphocytes is a clinical parameter used for AIDS diagnosis and follow-up. As this disease is particularly prevalent in developing countries, simple and affordable CD4 cell counting methods are urgently needed in resource-limited settings. This paper describes an electrochemical magneto-actuated biosensor for CD4 count in whole blood. The CD4(+) T lymphocytes were isolated, preconcentrated and labeled from 100 μL of whole blood by immunomagnetic separation with magnetic particles modified with antiCD3 antibodies. The captured cells were labeled with a biotinylated antiCD4 antibody, followed by the reaction with the electrochemical reporter streptavidin-peroxidase conjugate. The limit of detection for the CD4 counting magneto-actuated biosensor in whole blood was as low as 44 cells μL(-1) while the logistic range was found to be from 89 to 912 cells μL(-1), which spans the whole medical interest range for CD4 counts in AIDS patients. The electrochemical detection together with the immunomagnetic separation confers high sensitivity, resulting in a rapid, inexpensive, robust, user-friendly method for CD4 counting. This approach is a promising alternative for the costly standard flow cytometry and suitable as diagnostic tool at decentralized practitioner sites in low resource settings, especially in less developed countries. Copyright © 2015 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Bunde, Gary R.
A statistical comparison was made between two automated devices which were used to count data points (words, sentences, and syllables) needed in the Flesch Reading Ease Score to determine the reading grade level of written material. Determination of grade level of all Rate Training Manuals and Non-Resident Career Courses had been requested by the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alpert, B. K.; Horansky, R. D.; Bennett, D. A.
Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operationmore » at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.« less
Newell, Matthew R [Los Alamos, NM; Jones, David Carl [Los Alamos, NM
2009-09-01
A portable multiplicity counter has signal input circuitry, processing circuitry and a user/computer interface disposed in a housing. The processing circuitry, which can comprise a microcontroller integrated circuit operably coupled to shift register circuitry implemented in a field programmable gate array, is configured to be operable via the user/computer interface to count input signal pluses receivable at said signal input circuitry and record time correlations thereof in a total counting mode, coincidence counting mode and/or a multiplicity counting mode. The user/computer interface can be for example an LCD display/keypad and/or a USB interface. The counter can include a battery pack for powering the counter and low/high voltage power supplies for biasing external detectors so that the counter can be configured as a hand-held device for counting neutron events.
Nagasawa, Yuya; Kiku, Yoshio; Sugawara, Kazue; Tanabe, Fuyuko; Hayashi, Tomohito
2018-01-01
The exfoliation rate of mammary epithelial cells (MECs) in milk is affected by physiological, breeding and environmental factors. Little is known about the relationship between the MEC exfoliation into milk and mammary-infected Staphylococcus aureus (S. aureus) load on bovine mastitis caused by S. aureus. The aim of this study was to investigate the relationship between S. aureus load and the proportion of MEC exfoliation in milk using five substantial bovine mastitis models. In 64 randomly extracted milk samples from udders at 3-21 days after S. aureus infusion, there were various samples with different numbers of S. aureus counts and somatic cell counts. No significant correlations were found between the S. aureus counts and somatic cell count (r = 0.338). In contrast, a significant correlation was noted between S. aureus counts and the proportion of cytokeratin-positive cells in the milk from the infused udders (r = 0.734, P < 0.01). In conclusion, the increasing MEC exfoliation rate in milk from mastitis udders caused by S. aureus may contribute to reduced milk yield. © 2017 Japanese Society of Animal Science.
Annison, L; Dompreh, A; Adu-Sarkodie, Y
2013-12-01
The study sought to document the experience of immunological improvement among Ghanaian PLHIV on HAART comparing different categories of patients. Serology Unit, Komfo Anokye Teaching Hospital, Kumasi, Ghana. The study comprised a convenient sample of 303 treatment naïve HIV patients due to start HAART. Questionnaires were used to collect patient demographic and clinical data. Four CD4 counts were measured at six-monthly intervals to determine rates of CD4 change. These were pre-therapy, 1(st) post-therapy, 2(nd) post-therapy, and 3(rd) post-therapy counts. The rates of CD4 change among the different categories of patients were also compared. At baseline, women had higher CD4 count (mean of 77.4 cells/μl), and mean age of participants was 40 years. The CD4 count increased from a mean baseline of 70.2 cells/μl to 229.2, 270.0, and 297.6 cells/μl at 6, 12, and 18 months of treatment respectively (P < 0.0001 at each time point). There were no gender (P=0.46) and age (P=0.96) differences in treatment response. There was no difference (P=0.18) in treatment response comparing those with CD4 <250 cells/μl and those whose CD4 count was between 250 and 350 cells/μl at baseline although patients with baseline CD4 count <250 cells/μl showed larger increases after 12 months of treatment. Out of 282 patients with pre-therapy CD4 count ≤250 cells/μl, 241 (85.5%) and 41 (14.5%) were adherents and nonadherents respectively. Mean rate of increase was 15.2 and 8.4 cells/μl/month in adherent and non-adherent patients respectively (p=0.2). The study suggests that a sustained CD4 increase could be achieved in adherent patients commencing therapy with baseline CD4 count ≤250 cells/μl, and that these patients have greater ability for immunological recovery during 12 months of treatment The study, therefore, concludes that significant immunological improvement is possible among Ghanaian PLHIV on HAART as long as a high level of treatment adherence is observed.
Take 3 Steps Toward Preventing Infections During Cancer Treatment
... low white blood cell count (a condition called neutropenia) during your chemotherapy. Click on the appropriate button ... low white blood cell count (a condition called neutropenia) and infections during your chemotherapy. Learn More > Educational ...
Tang, Zhenzhu; Pan, Stephen W; Ruan, Yuhua; Liu, Xuanhua; Su, Jinming; Zhu, Qiuying; Shen, Zhiyong; Zhang, Heng; Chen, Yi; Lan, Guanghua; Xing, Hui; Liao, Lingjie; Feng, Yi; Shao, Yiming
2017-06-09
Current WHO guidelines recommend initiating ART regardless of CD4+ cell count. In response, we conducted an observational cohort study to assess the effects of pre-ART CD4+ cell count levels on death, attrition, and death or attrition in HIV treated patients. This large HIV treatment cohort study (n = 49,155) from 2010 to 2015 was conducted in Guangxi, China. We used a Cox regression model to analyze associations between pre-ART CD4+ cell counts and death, attrition, and death or attrition. The average mortality and ART attrition rates among all treated patients were 2.63 deaths and 5.32 attritions per 100 person-years, respectively. Compared to HIV patients with <350 CD4+ cells/mm 3 at ART initiation, HIV patients with >500 CD4+ cells/mm 3 at ART initiation had a significantly lower mortality rate (Adjusted hazard ratio: 0.56, 95% CI: 0.40-0.79), but significantly higher ART attrition rate (AHR: 1.17, 95% CI: 1.03-1.33). Results from this study suggest that HIV patients with high CD4+ cell counts at the time of ART initiation may be at greater risk of treatment attrition. To further reduce ART attrition, it is imperative that patient education and healthcare provider training on ART adherence be enhanced and account for CD4 levels at ART initiation.
On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors
Godfrey, B.; Anderson, T.; Breedon, E.; ...
2018-03-26
Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.
On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Godfrey, B.; Anderson, T.; Breedon, E.
Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.
Hamby, David M [Corvallis, OR; Farsoni, Abdollah T [Corvallis, OR; Cazalas, Edward [Corvallis, OR
2011-06-21
A technique and device provides absolute skin dosimetry in real time at multiple tissue depths simultaneously. The device uses a phoswich detector which has multiple scintillators embedded at different depths within a non-scintillating material. A digital pulse processor connected to the phoswich detector measures a differential distribution (dN/dH) of count rate N as function of pulse height H for signals from each of the multiple scintillators. A digital processor computes in real time from the differential count-rate distribution for each of multiple scintillators an estimate of an ionizing radiation dose delivered to each of multiple depths of skin tissue corresponding to the multiple scintillators embedded at multiple corresponding depths within the non-scintillating material.
A New Method for Calculating Counts in Cells
NASA Astrophysics Data System (ADS)
Szapudi, István
1998-04-01
In the near future, a new generation of CCD-based galaxy surveys will enable high-precision determination of the N-point correlation functions. The resulting information will help to resolve the ambiguities associated with two-point correlation functions, thus constraining theories of structure formation, biasing, and Gaussianity of initial conditions independently of the value of Ω. As one of the most successful methods of extracting the amplitude of higher order correlations is based on measuring the distribution of counts in cells, this work presents an advanced way of measuring it with unprecedented accuracy. Szapudi & Colombi identified the main sources of theoretical errors in extracting counts in cells from galaxy catalogs. One of these sources, termed as measurement error, stems from the fact that conventional methods use a finite number of sampling cells to estimate counts in cells. This effect can be circumvented by using an infinite number of cells. This paper presents an algorithm, which in practice achieves this goal; that is, it is equivalent to throwing an infinite number of sampling cells in finite time. The errors associated with sampling cells are completely eliminated by this procedure, which will be essential for the accurate analysis of future surveys.
Assessment of cell concentration and viability of isolated hepatocytes using flow cytometry.
Wigg, Alan J; Phillips, John W; Wheatland, Loretta; Berry, Michael N
2003-06-01
The assessment of cell concentration and viability of freshly isolated hepatocyte preparations has been traditionally performed using manual counting with a Neubauer counting chamber and staining for trypan blue exclusion. Despite the simple and rapid nature of this assessment, concerns about the accuracy of these methods exist. Simple flow cytometry techniques which determine cell concentration and viability are available yet surprisingly have not been extensively used or validated with isolated hepatocyte preparations. We therefore investigated the use of flow cytometry using TRUCOUNT Tubes and propidium iodide staining to measure cell concentration and viability of isolated rat hepatocytes in suspension. Analysis using TRUCOUNT Tubes provided more accurate and reproducible measurement of cell concentration than manual cell counting. Hepatocyte viability, assessed using propidium iodide, correlated more closely than did trypan blue exclusion with all indicators of hepatocyte integrity and function measured (lactate dehydrogenase leakage, cytochrome p450 content, cellular ATP concentration, ammonia and lactate removal, urea and albumin synthesis). We conclude that flow cytometry techniques can be used to measure cell concentration and viability of isolated hepatocyte preparations. The techniques are simple, rapid, and more accurate than manual cell counting and trypan blue staining and the results are not affected by protein-containing media.
Peña-Rehbein, Patricio; Ruiz, Karin; Ortloff, Alexander; Pizarro, María Isabel; Navarrete, Carolina
2013-01-01
Eleginops maclovinus has been an important fishery resource in Chile since 1957. Caligus rogercresseyi is one of the most prevalent ectoparasite species found on E. maclovinus. Hematocrit, hemoglobin level, red blood cell count (RBC), white blood cell count (WBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC) and differential white blood cell count were determined before and after an experimental infestation with C. rogercresseyi. We found significant differences in the hemoglobin level, WBC, MCV, MCH, MCHC, hematocrit level and RBC between infested and uninfested fish. Furthermore correlations between number of C. rogercresseyi with hematocrit, MCHC, neutrophil, eosinophil and lymphocyte counts were found. Hematological reference ranges of E. maclovinus in captivity conditions were also established.
Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model
Wilkinson, Holly N.; McBain, Andrew J.; Stephenson, Christian; Hardman, Matthew J.
2016-01-01
Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze using a wounded porcine skin biofilm model with standardized application parameters. Biofilm removal was determined using a surface viability assay, bacterial counts, histological assessment, and scanning electron microscopy (SEM). Results: Quantitative analysis revealed that monofilament debriding devices outperformed the standard gauze, resulting in up to 100-fold greater reduction in bacterial counts. Interestingly, histological and morphological analyses suggested that debridement not only removed bacteria, but also differentially disrupted the bacterially-derived extracellular polymeric substance. Finally, SEM of post-debridement monofilaments showed structural changes in attached bacteria, implying a negative impact on viability. Innovation: This is the first study to combine controlled and defined debridement application with a biologically relevant ex vivo biofilm model to directly compare monofilament debriding devices. Conclusion: These data support the use of monofilament debriding devices for the removal of established wound biofilms and suggest variable efficacy towards biofilms composed of different species of bacteria. PMID:27867752
Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting
Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay
2016-01-01
Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e− read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor. PMID:27070625
Reed, Mike; Kimberger, Oliver; McGovern, Paul D; Albrecht, Mark C
2013-08-01
Forced-air warming devices are effective for the prevention of surgical hypothermia. However, these devices intake nonsterile floor-level air, and it is unknown whether they have adequate filtration measures to prevent the internal buildup or emission of microbial contaminants. We rated the intake filtration efficiency of a popular current-generation forced-air warming device (Bair Hugger model 750, Arizant Healthcare) using a monodisperse sodium chloride aerosol in the laboratory. We further sampled 23 forced-air warming devices (same model) in daily hospital use for internal microbial buildup and airborne-contamination emissions via swabbing and particle counting. Laboratory testing found the intake filter to be 63.8% efficient. Swabbing detected microorganisms within 100% of the forced-air warming blowers sampled, with isolates of coagulase-negative staphylococci, mold, and micrococci identified. Particle counting showed 96% of forced-air warming blowers to be emitting significant levels of internally generated airborne contaminants out of the hose end. These findings highlight the need for upgraded intake filtration, preferably high-efficiency particulate air filtration (99.97% efficient), on current-generation forced-air warming devices to reduce contamination buildup and emission risks.
Aquino, Arturo; Millan, Borja; Gaston, Daniel; Diago, María-Paz; Tardaguila, Javier
2015-08-28
Grapevine flowering and fruit set greatly determine crop yield. This paper presents a new smartphone application for automatically counting, non-invasively and directly in the vineyard, the flower number in grapevine inflorescence photos by implementing artificial vision techniques. The application, called vitisFlower(®), firstly guides the user to appropriately take an inflorescence photo using the smartphone's camera. Then, by means of image analysis, the flowers in the image are detected and counted. vitisFlower(®) has been developed for Android devices and uses the OpenCV libraries to maximize computational efficiency. The application was tested on 140 inflorescence images of 11 grapevine varieties taken with two different devices. On average, more than 84% of flowers in the captures were found, with a precision exceeding 94%. Additionally, the application's efficiency on four different devices covering a wide range of the market's spectrum was also studied. The results of this benchmarking study showed significant differences among devices, although indicating that the application is efficiently usable even with low-range devices. vitisFlower is one of the first applications for viticulture that is currently freely available on Google Play.
Vichitvejpaisal, Pornpattana; Reeponmahar, Somporn; Tantisiriwat, Woraphot
2009-06-01
Typical progressive outer retinal necrosis (PORN) is an acute ocular infectious disease in acquired immunodeficiency syndrome (AIDS) patients with extremely low CD4+ T-cell counts. It is a form of the Varicella- zoster virus (VZV) infection. This destructive infection has an extremely rapid course that may lead to blindness in affected eyes within days or weeks. Attempts at its treatment have had limited success. We describe the case of a bilateral PORN in an AIDS patient with an initial CD4+ T-cell count >100 cells/microL that developed after initiation of highly active antiretroviral therapy (HAART). A 29-year-old Thai female initially diagnosed with human immunodeficiency virus (HIV) in 1998, presented with bilaterally decreased visual acuity after initiating HAART two months earlier. Multiple yellowish spots appeared in the deep retina without evidence of intraocular inflammation or retinal vasculitis. Her CD4+ T-cell count was 127 cells/microL. She was diagnosed as having PORN based on clinical features and positive VZV in the aqueous humor and vitreous by polymerase chain reaction (PCR). Despite combined treatment with intravenous acyclovir and intravitreous ganciclovir, the patient's visual acuity worsened with no light-perception in either eye. This case suggests that PORN should be included in the differential diagnosis of reduced visual acuity in AIDS patients initiating HAART with higher CD4+ T-cell counts. PORN may be a manifestation of the immune reconstitution syndrome.
Dinges, D F; Douglas, S D; Zaugg, L; Campbell, D E; McMann, J M; Whitehouse, W G; Orne, E C; Kapoor, S C; Icaza, E; Orne, M T
1994-05-01
The hypothesis that sleep deprivation depresses immune function was tested in 20 adults, selected on the basis of their normal blood chemistry, monitored in a laboratory for 7 d, and kept awake for 64 h. At 2200 h each day measurements were taken of total leukocytes (WBC), monocytes, granulocytes, lymphocytes, eosinophils, erythrocytes (RBC), B and T lymphocyte subsets, activated T cells, and natural killer (NK) subpopulations (CD56/CD8 dual-positive cells, CD16-positive cells, CD57-positive cells). Functional tests included NK cytotoxicity, lymphocyte stimulation with mitogens, and DNA analysis of cell cycle. Sleep loss was associated with leukocytosis and increased NK cell activity. At the maximum sleep deprivation, increases were observed in counts of WBC, granulocytes, monocytes, NK activity, and the proportion of lymphocytes in the S phase of the cell cycle. Changes in monocyte counts correlated with changes in other immune parameters. Counts of CD4, CD16, CD56, and CD57 lymphocytes declined after one night without sleep, whereas CD56 and CD57 counts increased after two nights. No changes were observed in other lymphocyte counts, in proliferative responses to mitogens, or in plasma levels of cortisol or adrenocorticotropin hormone. The physiologic leukocytosis and NK activity increases during deprivation were eliminated by recovery sleep in a manner parallel to neurobehavioral function, suggesting that the immune alterations may be associated with biological pressure for sleep.
Dinges, D F; Douglas, S D; Zaugg, L; Campbell, D E; McMann, J M; Whitehouse, W G; Orne, E C; Kapoor, S C; Icaza, E; Orne, M T
1994-01-01
The hypothesis that sleep deprivation depresses immune function was tested in 20 adults, selected on the basis of their normal blood chemistry, monitored in a laboratory for 7 d, and kept awake for 64 h. At 2200 h each day measurements were taken of total leukocytes (WBC), monocytes, granulocytes, lymphocytes, eosinophils, erythrocytes (RBC), B and T lymphocyte subsets, activated T cells, and natural killer (NK) subpopulations (CD56/CD8 dual-positive cells, CD16-positive cells, CD57-positive cells). Functional tests included NK cytotoxicity, lymphocyte stimulation with mitogens, and DNA analysis of cell cycle. Sleep loss was associated with leukocytosis and increased NK cell activity. At the maximum sleep deprivation, increases were observed in counts of WBC, granulocytes, monocytes, NK activity, and the proportion of lymphocytes in the S phase of the cell cycle. Changes in monocyte counts correlated with changes in other immune parameters. Counts of CD4, CD16, CD56, and CD57 lymphocytes declined after one night without sleep, whereas CD56 and CD57 counts increased after two nights. No changes were observed in other lymphocyte counts, in proliferative responses to mitogens, or in plasma levels of cortisol or adrenocorticotropin hormone. The physiologic leukocytosis and NK activity increases during deprivation were eliminated by recovery sleep in a manner parallel to neurobehavioral function, suggesting that the immune alterations may be associated with biological pressure for sleep. PMID:7910171
Jia, Hongcheng; Wang, Xuan; Hua, Wenhao; Li, Xiaoguang; Hou, Wen; Fu, Qian
2014-02-01
To investigate the correlation of CD(+)4 T lymphocyte count and prostaglandin E2 (PGE2) in gingival crevicular fluid (GCF) with periodontal status in HIV-positive patients with periodontitis. Twenty subjects were selected according to inclusion criteria. The plasmatic CD(+)4 T lymphocytes were counted. All the individuals were divided into three groups, group A (CD(+)4 T lymphocyte count < 200 cell/mm(3)), group B (200 cell/mm(3) ≤ CD(+)4 T lymphocyte count ≤ 500 cell/mm(3)) and group C (CD(+)4 T lymphocyte count > 500 cell/mm(3)). Periodontal indexes, including plaque index(PLI), bleeding index(BI), attachment level(AL) and probing depth(PD) were recorded.GCF samples were taken from 120 index teeth by means of sterile paper strips.GCF PGE2 levels were determined by radioimmunoassays. Mann-Whitney was used to compare the periodontal indexes and PGE2 levels among the three groups. Partial correlations and Spearman correlations were applied to analyze the correlation of CD(+)4 T lymphocytes count and PGE2 in gingival crevicular fluid with periodontal status. BI value, PGE2 concentration and total PGE2 were 3.00(2.00), 90.75(30.60) µg/L, 447.58 (243.08) pg in group B, which were higher than those in group A[2.00(1.25), 79.75(30.50) µg/L and 339.52 (200.97) pg respectively] and group C[2.00(1.00), 73.38 (14.83) µg/L and 299.18 (108.33) pg respectively] (P < 0.0167). But the differences of PD and AL among the three groups were not significantly different(P > 0.0167). The correlations were observed between CD(+)4 T lymphocyte count and BI for the subpopulations with CD(+)4 T lymphocyte count <200 cells/mm(3) (r = 0.657, P < 0.05) and between 200-500 cells/mm(3) (r = -0.369, P < 0.05). PGE2 concentration was negatively correlated with BI, PD and AL (P < 0.05), and total PGE2 was positively correlated with PD and AL(P < 0.05). There was an association between the periodontal status and CD(+)4 T lymphocyte count in HIV(+) patients.GCF PGE2 level was related to periodontal parameters including BI, PD and AL.
Vogler, Mary A; Teppler, Hedy; Gelman, Rebecca; Valentine, Fred; Lederman, Michael M; Pomerantz, Roger J; Pollard, Richard B; Cherng, Deborah Weng; Gonzalez, Charles J; Squires, Kathleen E; Frank, Ian; Mildvan, Donna; Mahon, Laura F; Schock, Barbara
2004-05-01
Approaches to preserve or enhance immune function in HIV-1 infection are needed. To examine the ability of daily low-dose interleukin-2 (IL-2) in combination with antiretroviral therapy to preserve circulating CD4+ T-cell counts, the clinical safety and tolerability of this treatment, and safety with respect to changes in plasma HIV-1 RNA levels. Twenty-four-week, phase 2, multicenter, randomized, open-label trial conducted at 12 AIDS Clinical Trials Units between September 1995 and May 1997. A total of 115 HIV-infected persons with screening CD4+ T-cell counts between 300 and 700 cells/mm who were on stable single- or dual-nucleoside therapy for at least 2 months, 11% of whom were also on a protease inhibitor at study entry. Patients were randomly assigned to receive IL-2 at a dose of 1 million IU subcutaneously once daily plus continued anti-retroviral therapy (ART + IL-2, n = 57) vs. continued ART alone (ART alone, n = 58). IL-2 dose reductions were made for objective or subjective toxicities. All subjects randomly assigned to the IL-2 arm who interrupted ART were also required to discontinue IL-2 for the same period. The primary endpoint was a decrease in CD4 T-cell count from baseline; the safety analysis was based on change in plasma HIV RNA by bDNA; and clinical safety and tolerability were analyzed by standard clinical criteria. Of the patients with a baseline CD4 T-cell count recorded, 15 (27%) of 55 patients randomly assigned to ART alone had a drop of > or =25% in their CD4 T-cell count and 23 (41%) of 56 patients randomly assigned to ART + IL-2 had a drop of > or =25% in their CD4 T-cell count at some time over the 24 weeks of the study. This difference was not statistically significant. There was a statistically significant greater variance in CD4 T-cell counts in the IL-2-treated group. More patients in the IL-2 group had at least a 25% increase in CD4 T-cell counts over baseline (34 vs. 13%, P = 0.007). A comparison of grade 3 or worse toxicity showed no differences between the arms, but IL-2 was associated with significantly more grade 2 or worse general body symptoms, primarily discomfort and fatigue. There was no significant difference between the groups with regard to changes in plasma HIV RNA, lymphocyte proliferation, natural killer cell activity, skin test responses to recall antigens, or antibody responses to immunization. Plasma markers of immune activation all increased significantly in IL-2 recipients. In patients with baseline CD4 T-cell counts > or =300 cells/mm primarily treated with single- or dual-nucleoside ART, subcutaneously administered IL-2 at a dose of 1 million IU daily for up to 24 weeks had low toxicity but showed no consistent benefit in preventing decline in CD4 T-cell counts and minimal evidence of immunologic improvement vs. continued ART alone.
Ji, Yongjia; Zhang, Fengdi; Zhang, Renfang; Shen, Yinzhong; Liu, Li; Wang, Jiangrong; Yang, Junyang; Tang, Qi; Xun, Jingna; Qi, Tangkai; Wang, Zhenyan; Song, Wei; Tang, Yang; Chen, Jun; Lu, Hongzhou
2018-06-22
The roles of immunodeficiency and combined antiretroviral therapy (cART) in shaping the gut microbiota in HIV-1-infected subjects (HISs) have not been described thoroughly by time-series investigations. In this study, 36 antiretroviral-naïve HISs were enrolled to prospectively assess alterations in the fecal microbiota and plasma markers of microbial translocation and inflammation with cART. At baseline, the species α-diversity of the fecal microbiota was significantly lower in HISs with a CD4 + T cell count <300/mm 3 than in HISs with a CD4 + T cell count >300/mm 3 (Shannon index: Median 2.557 vs. 2.981, P = 0.006; Simpson index: Median 0.168 vs. 0.096, P = 0.004). Additionally, the baseline α-diversity indices correlated with CD4 + T cell counts (Shannon index: r = 0.474, P = 0.004; Simpson index: r = -0.467, P = 0.004) and the specific plasma biomarkers for microbial translocation and inflammation. After cART introduction, the species α-diversity of fecal microbiota in HISs with CD4 + T cell counts <300/mm 3 was significantly restored (Shannon index: Median 2.557 vs. 2.791, P = 0.007; Simpson index: Median 0.168 vs. 0.112, P = 0.004), while the variances were insignificant among HISs with CD4+ T cell counts >300/mm 3 (Shannon index: Median 2.981 vs. 2.934, P = 0.179; Simpson index: Median 0.096 vs. 0.119, P = 0.082). Meanwhile, with cART introduction, alterations in the gut microbial composition were more significant in the subgroup with CD4 + T cell counts >300/mm 3 , corresponding to increases in the specific plasma inflammatory markers. These findings implicated the interactive roles of immunodeficiency and cART for affecting gut microbiota in HIV-1-infected individuals, providing new insights into intestinal microbiome dysbiosis related to HIV-1 infection.
The effects of proficiency and bias on residents' interpretation of the microscopic urinalysis.
Flach, Stephen D; Canaris, Gay J; Tape, Thomas G; Huntley, Kathryn M; Wigton, Robert S
2002-01-01
This study aims to determine whether residents are influenced by clinical information when interpreting microscopic urinalysis (UA) and estimating the probability of a urinary tract infection (UTI), and to determine the accuracy and reliability of UA readings. Residents estimated the UA white blood cell count and the probability of a UTI in vignettes using a fractional factorial design, varying symptoms, gender, and the white blood cell count on preprepared urine slides. Individual-level results indicated a clinical information bias and poor accuracy. Seventeen of 38 residents increased the white blood cell count in response to female gender; 14 increased the white blood cell count in response to UTI symptoms. Forty-nine percent of the readings were inaccurate; agreement ranged from 50% to 67% for white and red blood cells and bacteria. Many residents gave inaccurate UA readings, and many readings varied with clinical information. A significant portion of residents needs assistance in objectively and accurately interpreting the UA.
A Fluorescence Based Miniaturized Detection Module for Toxin Producing Algae
NASA Astrophysics Data System (ADS)
Zieger, S. E.; Mistlberger, G.; Troi, L.; Lang, A.; Holly, C.; Klimant, I.
2016-12-01
Algal blooms are sensitive to external environmental conditions and may pose a serious threat to marine and human life having an adverse effect on the ecosystem. Harmful algal blooms can produce different toxins, which can lead to massive fish kills or to human disorders. Facing these problems, miniaturized and low-cost instrumentation for an early detection and identification of harmful algae classes has become more important over the last years. 1,2Based on the characteristic pigment pattern of different algae classes, we developed a miniaturized detection module, which is able to detect and identify algae classes after analyzing their spectral behavior. Our device combines features of a flow-cytometer and fluorimeter and is build up as a miniaturized and low-cost device of modular design. Similar to a fluorimeter, it excites cells in the capillary with up to 8 different excitation wavelengths recording the emitted fluorescence at 4 different emission channels. Furthermore, the device operates in a flow-through mode similar to a flow-cytometer, however, using only low-cost elements such as LEDs and photodiodes. Due to its miniaturized design, the sensitivity and selectivity increase, whereas background effects are reduced. With a sampling frequency of 140 Hz, we try to detect and count particular cell events even at a concentration of 2 cells / 7.3 µL illuminated volume. Using a self-learning multivariate algorithm, the data are evaluated autonomously on the device enabling an in-situ analysis. The flexibility in choosing excitation and emission wavelengths as well as the high sampling rate enables laboratory applications such as measuring induction kinetics. However, in its first application, the device is part of an open and modular monitoring system enabling the sensing of chemical compounds such as toxic and essential Hg, Cd, Pb, As and Cu trace metal species, nutrients and species related to the carbon cycle, VOCs and potentially toxic algae classes (FP7 614002). 1. Faber, S. Saxitoxin and the Induction of Paralytic Shellfish Poisoning. J. Young Investig. 23,7 (2012). 2. Bláha, L., Babica, P. & Maršálek, B. Toxins produced in cyanobacterial water blooms - toxicity and risks. Interdiscip. Toxicol. 2, (2009).
Usefulness of hemocytometer as a counting chamber in a computer assisted sperm analyzer (CASA)
Eljarah, A.; Chandler, J.; Jenkins, J.A.; Chenevert, J.; Alcanal, A.
2013-01-01
Several methods are used to determine sperm cell concentration, such as the haemocytometer, spectrophotometer, electronic cell counter and computer-assisted semen analysers (CASA). The utility of CASA systems has been limited due to the lack of characterization of individual systems and the absence of standardization among laboratories. The aims of this study were to: 1) validate and establish setup conditions for the CASA system utilizing the haemocytometer as a counting chamber, and 2) compare the different methods used for the determination of sperm cell concentration in bull semen. Two ejaculates were collected and the sperm cell concentration was determined using spectrophotometer and haemocytometer. For the Hamilton-Thorn method, the haemocytometer was used as a counting chamber. Sperm concentration was determined three times per ejaculate samples. A difference (P 0.05) or between the haemocytometer count and the spectrophotometer. Based on the results of this study, we concluded that the haemocytometer can be used in computerized semen analysis systems as a substitute for the commercially available disposable counting chambers, therefore avoiding disadvantageous high costs and slower procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Chad; Gomez, Daniel R.; Wang, Hongmei
Purpose: Radiation pneumonitis (RP) is an inflammatory response to radiation therapy (RT). We assessed the association between RP and white blood cell (WBC) count, an established metric of systemic inflammation, after RT for non-small cell lung cancer. Methods and Materials: We retrospectively analyzed 366 patients with non-small cell lung cancer who received ≥60 Gy as definitive therapy. The primary endpoint was whether WBC count after RT (defined as 2 weeks through 3 months after RT completion) was associated with grade ≥3 or grade ≥2 RP. Median lung volume receiving ≥20 Gy (V{sub 20}) was 31%, and post-RT WBC counts rangedmore » from 1.7 to 21.2 × 10{sup 3} WBCs/μL. Odds ratios (ORs) associating clinical variables and post-RT WBC counts with RP were calculated via logistic regression. A recursive-partitioning algorithm was used to define optimal post-RT WBC count cut points. Results: Post-RT WBC counts were significantly higher in patients with grade ≥3 RP than without (P<.05). Optimal cut points for post-RT WBC count were found to be 7.4 and 8.0 × 10{sup 3}/μL for grade ≥3 and ≥2 RP, respectively. Univariate analysis revealed significant associations between post-RT WBC count and grade ≥3 (n=46, OR=2.6, 95% confidence interval [CI] 1.4‒4.9, P=.003) and grade ≥2 RP (n=164, OR=2.0, 95% CI 1.2‒3.4, P=.01). This association held in a stepwise multivariate regression. Of note, V{sub 20} was found to be significantly associated with grade ≥2 RP (OR=2.2, 95% CI 1.2‒3.4, P=.01) and trended toward significance for grade ≥3 RP (OR=1.9, 95% CI 1.0-3.5, P=.06). Conclusions: Post-RT WBC counts were significantly and independently associated with RP and have potential utility as a diagnostic or predictive marker for this toxicity.« less
Hedberg, P; Lehto, T
2009-02-01
This study presents the results of an aging stability study of complete blood count (CBC) and leukocyte differential parameters using the Abbott CELL-DYN Sapphire hematology analyzer. Stability studies showed no substantial change in CBC parameters up to 24-48 h at +23 +/- 2 degrees C (room temperature), except for optical platelet count (PLTo). For specimens aged over 24, the value of impedance platelet count yielded more reliable results than the routine PLTo. White blood cell (WBC) differential parameters, except eosinophils, were stable for up to 48 h at +23 +/- 2 degrees C. CBC parameters were stable for 72 h, except mean platelet volume, which slightly increased between 48 and 72 h, at +4 degrees C. WBC differentials were stable 48-72 h, with a slight decrease observed in absolute neutrophils and lymphocytes at +4 degrees C.
Belviranli, Muaz; Okudan, Nilsel; Kabak, Banu
2017-07-19
The objective of the study was to determine the effects of acute high-intensity interval training (HIIT) on hematological parameters in sedentary men. Ten healthy, non-smoker, and sedentary men aged between 18 and 24 years participated in the study. All subjects performed four Wingate tests with 4 min intervals between the tests. Blood samples were collected at pre-exercise, immediately after, 3 and 6 h after the fourth Wingate test. Hematological parameters were analyzed in these samples. The results showed that hematocrit percentage, hemoglobin values, red cell count, mean cell volume, platelet count, total white cell count, and counts of the white cell subgroups increased immediately after the acute HIIT and their values began to return to resting levels 3 h after exercise, and completely returned to resting levels 6 h after exercise. In conclusion, acute HIIT causes an inflammatory response in blood.
A new clocking method for a charge coupled device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Umezu, Rika; Kitamoto, Shunji, E-mail: kitamoto@rikkyo.ac.jp; Murakami, Hiroshi
2014-07-15
We propose and demonstrate a new clocking method for a charge-coupled device (CCD). When a CCD is used for a photon counting detector of X-rays, its weak point is a limitation of its counting rate, because high counting rate makes non-negligible pile-up of photons. In astronomical usage, this pile-up is especially severe for an observation of a bright point-like object. One typical idea to reduce the pile-up is a parallel sum (P-sum) mode. This mode completely loses one-dimensional information. Our new clocking method, panning mode, provides complementary properties between the normal mode and the P-sum mode. We performed a simplemore » simulation in order to investigate a pile-up probability and compared the simulated result and actual obtained event rates. Using this simulation and the experimental results, we compared the pile-up tolerance of various clocking modes including our new method and also compared their other characteristics.« less
Image charge multi-role and function detectors
NASA Astrophysics Data System (ADS)
Milnes, James; Lapington, Jon S.; Jagutzki, Ottmar; Howorth, Jon
2009-06-01
The image charge technique used with microchannel plate imaging tubes provides several operational and practical benefits by serving to isolate the electronic image readout from the detector. The simple dielectric interface between detector and readout provides vacuum isolation and no vacuum electrical feed-throughs are required. Since the readout is mechanically separate from the detector, an image tube of generic design can be simply optimised for various applications by attaching it to different readout devices and electronics. We present imaging performance results using a single image tube with a variety of readout devices suited to differing applications: (a) A four electrode charge division tetra wedge anode, optimised for best spatial resolution in photon counting mode. (b) A cross delay line anode, enabling higher count rate, and the possibility of discriminating near co-incident events, and an event timing resolution of better than 1 ns. (c) A multi-anode readout connected, either to a multi-channel oscilloscope for analogue measurements of fast optical pulses, or alternately, to a multi-channel time correlated single photon counting (TCSPC) card.
Consequence of changing standards for somatic cell count on US Dairy Herd Improvement herds
USDA-ARS?s Scientific Manuscript database
Consequence of noncompliance with European Union (EU) and current US standards for somatic cell count (SCC) as well as SCC standards proposed by the National Milk Producers Federation was examined for US herds. Somatic cell scores (SCS) from 14,854 Dairy Herd Improvement (DHI) herds were analyzed. H...
Jasper, Phillip W; James, Melva T; Hoover, Adam W; Muth, Eric R
2016-11-01
New technologies are emerging that may help individuals engage in healthier eating behaviors. One paradigm to test the efficacy of a technology is to determine its effect relative to environment cues that are known to cause individuals to overeat. The purpose of this work was to independently investigate two questions: How does the presence of a technology that provides bite count feedback alter eating behavior? and, How does the presence of a technology that provides bite count feedback paired with a goal alter eating behavior? Two studies investigated these research questions. The first study tested the effects of a large and small plate crossed with the presence or absence of a device that provided bite count feedback on intake. The second study tested the effects of a bite count goal with bite count feedback, again crossed with plate size, on intake. Both studies used a 2×2 between-subjects design. In the first study, 94 subjects (62 women aged 19.0±1.6 years with body mass index [BMI] 23.04±3.6) consumed lunch in a laboratory. The second study examined 99 subjects (56 women aged 18.5±1.5 years with BMI 22.73±2.70) under the same conditions. In both studies subjects consumed a single-course meal, using either a small or large plate. In the first study participants either wore or did not wear an automated bite counting device. In the second study all participants wore the bite counting device and were given either a low bite count goal (12 bites) or a high bite count goal (22 bites). Effect of plate size, feedback, and goal on consumption (grams) and number of bites taken were assessed using 2×2 analyses of variance. As adjunct measures, the effects of serving size, bite size (grams per bite), postmeal satiety, and satiety change were also assessed. In the first study there was a main effect of plate size on grams consumed and number of bites taken such that eating from a large plate led to greater consumption (P=0.001) and a greater number of bites (P=0.001). There was also a main effect of feedback on consumption and number of bites taken such that those who received feedback consumed less (P=0.011) and took fewer bites (P<0.001). In the second study there was a main effect of plate size on consumption such that those eating from a large plate consumed more (P=0.003) but did not take more bites. Further analysis revealed a main effect of goal on number of bites taken such that those who received the low goal took fewer bites (P<0.001) but did not consume less. Providing feedback on the number of bites taken from a wearable intake monitor can reduce overall intake during a single meal. Regarding the first research question, providing feedback significantly reduced intake in both plate size groups and reduced the overall number of bites taken. Regarding the second research question, participants were successful in eating to their goals. However, individuals in the low goal condition appeared to compensate for the restricted goal by taking larger bites, leading to comparable levels of consumption between the low and high goal groups. Hence, the interaction of technology with goals should be considered when introducing a health intervention. Copyright © 2016 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
In vitro ovine articular chondrocyte proliferation: experiments and modelling.
Mancuso, L; Liuzzo, M I; Fadda, S; Pisu, M; Cincotti, A; Arras, M; La Nasa, G; Concas, A; Cao, G
2010-06-01
This study focuses on analysis of in vitro cultures of chondrocytes from ovine articular cartilage. Isolated cells were seeded in Petri dishes, then expanded to confluence and phenotypically characterized by flow cytometry. The sigmoidal temporal profile of total counts was obtained by classic haemocytometry and corresponding cell size distributions were measured electronically using a Coulter Counter. A mathematical model recently proposed (1) was adopted for quantitative interpretation of these experimental data. The model is based on a 1-D (that is, mass-structured), single-staged population balance approach capable of taking into account contact inhibition at confluence. The model's parameters were determined by fitting measured total cell counts and size distributions. Model reliability was verified by predicting cell proliferation counts and corresponding size distributions at culture times longer than those used when tuning the model's parameters. It was found that adoption of cell mass as the intrinsic characteristic of a growing chondrocyte population enables sigmoidal temporal profiles of total counts in the Petri dish, as well as cell size distributions at 'balanced growth', to be adequately predicted.
Micro-inflammation in functional dyspepsia: A systematic review and meta-analysis.
Du, L; Chen, B; Kim, J J; Chen, X; Dai, N
2018-04-01
Functional dyspepsia (FD) is a gastrointestinal disorder of unknown etiology. Although micro-inflammation appears to be important in the pathogenesis, studies evaluating immune activation in FD have been inconsistent. A systematic review of literature and meta-analysis was performed to compare immunologic cell counts and cytokine levels in the mucosa and peripheral blood of individuals with FD and healthy controls. PubMed, Embase, and the Cochrane library were searched. Data on immunologic cell counts and cytokines levels among individuals with FD and control groups were extracted and compared by calculating standard mean differences (SMD). Thirty-seven studies met the inclusion criteria. Mast cell (SMD = 0.94, 95%CI 0.26-1.62, P = .007) and eosinophil counts (SMD = 0.36, 95%CI 0.06-0.68, P = .03) in the stomach were increased, among individuals with FD compared to controls. Similarly, mast cell (SMD = 0.66, 95%CI 0.20-1.13, P = 0.005) and eosinophil (SMD = 0.95, 95%CI 0.66-1.24; P < .001) counts in the duodenum were also increased in those with FD compared to controls. In a subgroup analysis, elevated eosinophil counts in the duodenum were observed in both post-prandial distress syndrome (SMD = 0.97, 95%CI 0.46-1.47, P = .0002) and epigastric pain syndrome subtypes (SMD = 1.16, 95%CI 0.48-1.83, P = .0008). No differences in mucosal intraepithelial lymphocyte, enterochromaffin cell, and neutrophil counts, as well as, peripheral interlukin-6 (IL-6) and IL-10 levels were observed among individuals with FD and controls. Micro-inflammation in the form of local immune cell infiltration, particularly eosinophils and mast cells, characterizes the pathogenesis of FD. © 2018 John Wiley & Sons Ltd.
2000-07-07
To determine if triple combination therapy, particularly including HIV protease inhibitors (PI), confers an unique immunological benefit that is independent of reductions of plasma viral load (pVL). The correlation between changes from baseline in CD4 cell count and pVL was examined at all time points up to 52 weeks in three randomized clinical trials (AVANTI-2, AVANTI-3 and INCAS) that compared dual nucleoside therapy with triple combination therapy. Individual pVL and CD4 cell counts changes from baseline were entered into multivariate linear regression models for patients receiving double therapy and for those receiving triple therapy including a PI and/or a non-nucleoside reverse transcriptase inhibitor (NNRTI), and the null hypothesis was tested. After 52 weeks of therapy, the relationship between changes from baseline CD4 cell count and pVL was independent of whether patients were assigned double or triple therapy (P = 0.23 and 0.69 for intercept and slope, respectively), or whether patients were assigned triple therapy including a PI or triple therapy including an NNRTI (P = 0.92 and 0.95, respectively). Less than 5% of patients ever had 'discordant' increases in both CD4 cell count and pVL compared with baseline, and this proportion was unrelated to the class of therapy used. 'Discordant' decreases from baseline in both parameters were observed in up to 35% of individuals. The correlation between pVL and CD4 cell count changes from baseline improved over time on therapy, regardless of the therapeutic regimen involved. The data provide no evidence for a CD4 cell count benefit of highly active antiretroviral therapy (HAART) unique to triple therapy or PI-containing regimens.
Radiation detectors and sources enhanced with micro/nanotechnology
NASA Astrophysics Data System (ADS)
Whitney, Chad Michael
The ongoing threat of nuclear terrorism presents major challenges to maintaining national security. Currently, only a small percentage of the cargo containers that enter America are searched for fissionable bomb making materials. This work reports on a multi-channel radiation detection platform enabled with nanoparticles that is capable of detecting and discriminating all types of radiation emitted from fissionable bomb making materials. Typical Geiger counters are limited to detecting only beta and gamma radiation. The micro-Geiger counter reported here detects all species of radiation including beta particles, gamma/X-rays, alpha particles, and neutrons. The multi-species detecting micro-Geiger counter contains a hermetically sealed and electrically biased fill gas. Impinging radiation interacts with tailored nanoparticles to release secondary charged particles that ionize the fill gas. The ionized particles collect on respectively biased electrodes resulting in a characteristic electrical pulse. Pulse height spectroscopy and radiation energy binning techniques can then be used to analyze the pulses to determine the specific radiation isotope. The ideal voltage range of operation for energy discrimination was found to be in the proportional region at 1000VDC. In this region, specific pulse heights for different radiation species resulted. The amplification region strength which determines the device sensitivity to radiation energy can be tuned with the electrode separation distance. Considerable improvements in count rates were achieved by using the charge conversion nanoparticles with the highest cross sections for particular radiation species. The addition of tungsten nanoparticles to the microGeiger counter enabled the device to be four times more efficient at detecting low level beta particles with a dose rate of 3.2uR/hr (micro-Roentgen per hour) and just under three times more efficient than an off the shelf Geiger counter. The addition of lead nanoparticles enabled the gamma/X-ray microGeiger counter channel to be 28 times more efficient at detecting low level gamma rays with a dose rate of 10uR/hr when compared to a device without nanoparticles. The addition of 10B nanoparticles enabled the neutron microGeiger counter channel to be 17 times more efficient at detecting neutrons. The device achieved a neutron count rate of 9,866 counts per minute when compared to a BF3 tube which resulted in a count rate of 9,000 counts per minute. By using a novel micro-injection ceramic molding and low temperature (950°C) silver paste metallizing process, the batch fabrication of essentially disposable micro-devices can be achieved. This novel fabrication technique was then applied to a MEMS neutron gun and water spectroscopy device that also utilizes the high voltage/temperature insulating packaging.
Cytoprotection: Immune and Matrix Modulation of Tissue Repair
2012-04-01
bronchoalveolar lavage (BAL) fluid for cytokines, cell counts and eosinophilia, and histological analysis of airway hyper-responsiveness and remodeling...OVA administered intra-nasally on Days 21–25 with or without 0.1% XHA. B) Total leukocyte and eosinophil counts in bronchoalveolar lavage (BAL) fluid...and different doses of HA peptide. The absolute number of Tmr+ and FOXP3+ populations was determined using total cell counts and flow cytometry for Tmr
NASA Technical Reports Server (NTRS)
Smith, Stephen
2011-01-01
We are developing arrays of transition-edge sensor (TES) X-ray detectors optimized for high count-rate solar astronomy applications where characterizing the high velocity motions of X-ray jets in solar flares is of particular interest. These devices are fabricated on thick Si substrates and consist of 35x35micron^2 TESs with 4.5micron thick, 60micron pitch, electroplated absorbers. We have tested devices fabricated with different geometric stem contact areas with the TES and surrounding substrate area, which allows us to investigate the loss of athermal phonons to the substrate. Results show a correlation between the stem contact area and a non-Gaussian broadening in the spectral line shape consistent with athermal phonon loss. When the contact area is minimized we have obtained remarkable board-band spectral resolving capabilities of 1.3 plus or minus 0.leV at an energy of 1.5 keV, 1.6 plus or minus 0.1 eV at 5.9 keV and 2.0 plus or minus 0.1 eV at 8 keV. This, coupled with a capability of accommodating 100's of counts per second per pixel makes these devices an exciting prospect of future x-ray astronomy applications.
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
Kouabosso, André; Mossoro-Kpinde, Christian Diamant; Bouassa, Ralph-Sydney Mboumba; Longo, Jean De Dieu; Mbeko Simaleko, Marcel; Grésenguet, Gérard; Bélec, Laurent
2018-04-01
The accuracy of CD4 T cell monitoring by the recently developed flow cytometry-based CD4 T cell counting Muse™ Auto CD4/CD4% Assay analyzer (EMD Millipore Corporation, Merck Life Sciences, KGaA, Darmstadt, Germany) was evaluated in trained lay providers against laboratory technicians. After 2 days of training on the Muse™ Auto CD4/CD4% analyzer, EDTA-blood samples from 6 HIV-positive and 4 HIV-negative individuals were used for CD4 T cell counting in triplicate in parallel by 12 trained lay providers as compared to 10 lab technicians. Mean number of CD4 T cells in absolute number was 829 ± 380 cells/μl by lay providers and 794 ± 409 cells/μl by technicians (P > 0.05); and in percentage 36.2 ± 14.8%CD4 by lay providers and 36.1 ± 15.0%CD4 by laboratory technician (P > 0.05). The unweighted linear regression and Passing-Bablok regression analyses on CD4 T cell results expressed in absolute count revealed moderate correlation between CD4 T cell counts obtained by lay providers and lab technicians. The mean absolute bias measured by Bland-Altman analysis between CD4 T cell/μl obtained by lay providers and lab technicians was -3.41 cells/μl. Intra-assay coefficient of variance (CV) of Muse™ Auto CD4/CD4% in absolute number was 10.1% by lay providers and 8.5% by lab technicians (P > 0.05), and in percentage 5.5% by lay providers and 4.4% by lab technicians (P > 0.05). The inter-assay CV of Muse™ Auto CD4/CD4% in absolute number was 13.4% by lay providers and 10.3% by lab technicians (P > 0.05), and in percentage 7.8% by lay providers and 6.9% by lab technicians (P > 0.05). The study demonstrates the feasibility of CD4 T cell counting using the alternative flow cytometer Muse™ Auto CD4/CD4% analyzer by trained lay providers and therefore the practical possibility of decentralization CD4 T cell counting to health community centers. Copyright © 2018. Published by Elsevier B.V.
Stritesky, Gretta; Wadsworth, Kimberly; Duffy, Merry; Buck, Kelly; Dehn, Jason
2018-02-01
Umbilical cord blood units provide an important stem cell source for transplantation, particularly for patients of ethnic diversity who may not have suitably matched available, adult-unrelated donors. However, with the cost of cord blood unit acquisition from public banks significantly higher than that for adult-unrelated donors, attention is focused on decreasing cost yet still providing cord blood units to patients in need. Historical practices of banking units with low total nucleated cell counts, including units with approximately 90 × 10 7 total nucleated cells, indicates that most banked cord blood units have much lower total nucleated cell counts than are required for transplant. The objective of this study was to determine the impact on the ability to identify suitable cord blood units for transplantation if the minimum total nucleated cell count for banking were increased from 90 × 10 7 to 124 or 149 × 10 7 . We analyzed ethnically diverse patients (median age, 3 years) who underwent transplantation of a single cord blood unit in 2005 to 2016. A cord blood unit search was evaluated to identify units with equal or greater human leukocyte antigen matching and a greater total nucleated cell count than that of the transplanted cord blood unit (the replacement cord blood unit). If the minimum total nucleated cell count for banking increased to 124 or 149 × 10 7 , then from 75 to 80% of patients would still have at least 1 replacement cord blood unit in the current (2016) cord blood unit inventory. The best replacement cord blood units were often found among cords with the same ethnic background as the patient. The current data suggest that, if the minimum total nucleated cell count were increased for banking, then it would likely lead to an inventory of more desirable cord blood units while having minimal impact on the identification of suitable cord blood units for transplantation. © 2017 AABB.
NOEL, Edva; ESPERANCE, Morgan; MCLAUGHLIN, Megan; BERTRAND, Rachel; DEVIEUX, Jessy; SEVERE, Patrice; MARCELIN, Abdias; NICOTERA, Janet; DELCHER, Chris; GRISWOLD, Mark; MEREDITH, Genevive; PAPE, Jean William; KOENIG, Serena P
2013-01-01
Objective We report rates and risk factors for attrition in the first cohort of patients followed through all stages from HIV testing to ART initiation. Design Cohort study of all patients diagnosed with HIV between January and June, 2009. Methods We calculated the proportion of patients who completed CD4 cell counts and initiated ART or remained in pre-ART care during two years of follow-up, and assessed predictors of attrition. Results Of 1,427 patients newly diagnosed with HIV, 680 (48%) either initiated ART or were retained in pre-ART care for the subsequent two years. One thousand eighty-three patients (76%) received a CD4 cell count and 973 (90%) returned for result; 297 (31%) had CD4 cell count < 200 cells/μl and of these, 256 (86%) initiated ART. Among 429 patients with CD4 > 350 cells/μl, 215 (50%) started ART or were retained in pre-ART care. Active TB was associated with lower odds of attrition prior to CD4 cell count (OR: 0.08; 95% CI: 0.03–0.25) but also higher odds of attrition prior to ART initiation (OR: 2.46; 95% CI: 1.29–4.71). Lower annual income (≤ $US125) was associated with higher odds of attrition prior to CD4 cell count (OR 1.65; 95% CI: 1.25–2.19), and prior to ART initiation among those with CD4 cell count > 350 cells/μl (OR: 1.74; 95% CI: 1.20–2.52). After tracking patients through a national database, the retention rate increased to only 57%. Conclusion Fewer than half of patients newly diagnosed with HIV initiate ART or remain in pre-ART care for two years in a clinic providing comprehensive services. Additional efforts to improve retention in pre-ART are critically needed. PMID:23254154
USDA-ARS?s Scientific Manuscript database
New European Union (E.U.) regulations may require that a somatic cell count (SCC) limit of 400,000 cells/mL for milk be met by every farm that contributes to pooled milk exported to Europe. In the United States, the standard is 750,000 cells/mL. Because bulk tank SCC is not readily available through...
A systematic assessment of goblet cell sampling of the bulbar conjunctiva by impression cytology.
Doughty, Michael J
2015-07-01
The purpose of this study was to assess the apparent goblet cell density (GCD) from conjunctival impression cytology (CIC) samples in relation to the number of conjunctival cells collected onto the filters. CIC specimens were collected from the superior-temporal bulbar conjunctiva of 16 pigmented rabbits onto Biopore (Millicell-CM) membranes, fixed with buffered glutaraldehyde and stained with Giemsa. Different numbers of microscope fields of view in each of the specimens were imaged by light microscopy using a 20× magnification objective lens (200× final magnification), and the goblet cells marked and counted. The GCD values/sq. mm were calculated. The same conjunctival region of 3 other rabbits was also prepared for transmission electron microscopy (TEM) by fixation, in situ, with the same buffered glutaraldehyde. Mean values for GCD estimates were found to vary from 399 to 1576 cells/sq. mm, depending on the image sampling and analysis strategy chosen, with the lowest inter-sample variance of around 10% being found if a maximum goblet cell count was taken on substantially multilayered regions of the CIC specimens. Counts of the number of goblet cells per 1000 visible conjunctival epithelial cells yielded a value of close to 90 (range 36-151), with modest inter-sample variability of around 30%. A three or ten 200× microscope field and random sampling strategy yielded mean GCD values between 542 and 670 cells/sq. mm, but with very high intra- and inter-sample variance of at least 60% and sometimes higher than 100%. TEM confirmed the multilayered organization of the conjunctiva and the deeper lying goblet cells. The general use of a goblet cell count as an objective marker for conjunctival normality or health is likely to be highly variable unless a more specific strategy is adopted. Beyond providing details of exactly the counting strategy used, it would be very useful to provide full details of the actual microscope field size used as well as information on the intra-sample variability in goblet cell counts. Copyright © 2015 Elsevier Ltd. All rights reserved.
2012-01-01
Background A mobile health unit may be useful to follow up adult and pediatric patients on antiretroviral treatment and living in remote areas devoid of laboratory facilities. The study evaluated the use of the simplified, robust, single-plateform, volumetric, pan-leucogating Auto40 flow cytometer (Apogee Flow Systems Ltd, Hemel Hempstead, UK) for CD4 T cell numeration in a mobile unit, compared against a reference flow cytometry method. Methods The therapeutic mobile unit of the Laboratoire National de Santé Hygiène Mobile, Yaoundé, Cameroon, was equipped with the Auto40. A FACSCalibur flow cytometer (Becton Dickinson Immuno-cytometry System, San Jose, CA, USA) was used as reference method. EDTA-blood samples from volunteers were first subjected to CD4 T cell count in the mobile unit, and an aliquot was sent within 4 hours to Centre International de Référence Chantal Biya, Yaoundé, for FACSCalibur assay. Results Two HIV screening campaigns with the mobile unit were organised in December 2009 and January 2010. The campaign in the suburb of Yaoundé which was 20 km from the reference laboratory included 188 volunteers comprising 93 children less than 5 years old. The campaign in Ambang Bikok (53 km far from Yaoundé) included 69 adult volunteers. In Yaoundé suburb, mean ± standard deviation (SD) CD4 T cell count was 996 ± 874 cells/μl by Auto40, and 989 ± 883 cells/μl by FACSCalibur; in Ambang Bikok, mean ± SD CD4 T cell count was 1041 ± 317 cells/μl by Auto40, and 1032 ± 294 cells/μl by FACSCalibur. Results by Auto40 and FACSCalibur were highly correlated in Yaoundé (r2 = 0.982) as in Ambang Bikok (r2 = 0.921). Bland-Altman analysis showed a close agreement between Auto40 and FACSCalibur results expressed in absolute count as in percentage in Yaoundé and Ambang Bikok. When pooling the 257 CD4 T cell count measurements, the Auto40 yielded a mean difference of +7.6 CD4 T cells/μl higher than by reference flow cytometry; and the sensitivity and specificity of Auto40 in enumerating absolute CD4 T cell counts of less than 200 cells/μl were 87% and 99%, respectively, and in enumerating absolute CD4 T cell counts of less than 350 cells/μl were 87% and 98%, respectively. The intrarun and interun precisions of the Auto40 assay assessed in the mobile unit were 5.5% and 7.9%, respectively. Conclusions The Auto40 flow cytometer installed in a therapeutic mobile unit and operated far from its reference laboratory gave a perfect correlation with the reference method, and could be useful in carrying out immunological monitoring of HIV-infected patients living in areas without access to laboratory facilities. PMID:22309994
Patient warming excess heat: the effects on orthopedic operating room ventilation performance.
Belani, Kumar G; Albrecht, Mark; McGovern, Paul D; Reed, Mike; Nachtsheim, Christopher
2013-08-01
Patient warming has become a standard of care for the prevention of unintentional hypothermia based on benefits established in general surgery. However, these benefits may not fully translate to contamination-sensitive surgery (i.e., implants), because patient warming devices release excess heat that may disrupt the intended ceiling-to-floor ventilation airflows and expose the surgical site to added contamination. Therefore, we studied the effects of 2 popular patient warming technologies, forced air and conductive fabric, versus control conditions on ventilation performance in an orthopedic operating room with a mannequin draped for total knee replacement. Ventilation performance was assessed by releasing neutrally buoyant detergent bubbles ("bubbles") into the nonsterile region under the head-side of the anesthesia drape. We then tracked whether the excess heat from upper body patient warming mobilized the "bubbles" into the surgical site. Formally, a randomized replicated design assessed the effect of device (forced air, conductive fabric, control) and anesthesia drape height (low-drape, high-drape) on the number of bubbles photographed over the surgical site. The direct mass-flow exhaust from forced air warming generated hot air convection currents that mobilized bubbles over the anesthesia drape and into the surgical site, resulting in a significant increase in bubble counts for the factor of patient warming device (P < 0.001). Forced air had an average count of 132.5 versus 0.48 for conductive fabric (P = 0.003) and 0.01 for control conditions (P = 0.008) across both drape heights. Differences in average bubble counts across both drape heights were insignificant between conductive fabric and control conditions (P = 0.87). The factor of drape height had no significant effect (P = 0.94) on bubble counts. Excess heat from forced air warming resulted in the disruption of ventilation airflows over the surgical site, whereas conductive patient warming devices had no noticeable effect on ventilation airflows. These findings warrant future research into the effects of forced air warming excess heat on clinical outcomes during contamination-sensitive surgery.
Owens, Brett D; White, Daniel W; Wenke, Joseph C
2009-01-01
There is much to learn about the effectiveness of different methods currently used for the irrigation of open wounds. The purpose of this study was to compare various approaches in a survival animal model. We used an established goat model involving the creation of a reproducible complex musculoskeletal wound followed by inoculation with Pseudomonas aeruginosa (lux) bacteria. This genetically altered luminescent bacterium provides the ability for quantitative analysis with a photon-counting camera system. For Study 1, wound irrigation was performed six hours after the injury and inoculation; the goats were assigned to four treatment groups: normal saline solution, bacitracin solution, castile soap, and benzalkonium chloride. All wounds received sharp débridement and irrigation with use of a pulsatile lavage device (19 psi). Images and photon counts were obtained prior to irrigation, after irrigation, and forty-eight hours after injury and inoculation. For Study 2, we used the same animal model and compared bulb syringe and pulsatile lavage irrigation with saline solution. In Study 1, the irrigation treatment lowered the bacterial counts in all treatment groups. The greatest reduction was seen with castile soap, which lowered the photon count to 13% of the pretreatment level. This was followed by benzalkonium chloride, bacitracin, and saline solution at 18%, 22%, and 29%, respectively. At forty-eight hours, imaging showed a rebound in bacterial counts in every group. The highest rebound was measured in the castile soap group, which rebounded to 120% of the pretreatment level. The benzalkonium chloride group experienced a rebound to 94% of the pretreatment level. These were followed by bacitracin solution (89%) and normal saline solution (68%). In Study 2, both treatment methods were effective in removing 75% of the bacteria initially. At forty-eight hours, the bacterial levels in the pulsed lavage group rebounded to 94% of the original levels (compared with 48% in the bulb syringe group). The difference in the mean photon count ratios at forty-eight hours was significant (p = 0.048). Approaches used to remove bacteria from wounds, such as irrigants other than saline solution or high-pressure devices, may not have the best clinical outcome.
Pérez-Santiago, Josué; Ouchi, Dan; Urrea, Victor; Carrillo, Jorge; Cabrera, Cecilia; Villà-Freixa, Jordi; Puig, Jordi; Paredes, Roger; Negredo, Eugènia; Clotet, Bonaventura; Massanella, Marta; Blanco, Julià
2016-01-01
Background: The failure to increase CD4+ T-cell counts in some antiretroviral therapy suppressed participants (immunodiscordance) has been related to perturbed CD4+ T-cell homeostasis and impacts clinical evolution. Methods: We evaluated different definitions of immunodiscordance based on CD4+ T-cell counts (cutoff) or CD4+ T-cell increases from nadir value (ΔCD4) using supervised random forest classification of 74 immunological and clinical variables from 196 antiretroviral therapy suppressed individuals. Unsupervised clustering was performed using relevant variables identified in the supervised approach from 191 individuals. Results: Cutoff definition of CD4+ cell count 400 cells/μl performed better than any other definition in segregating immunoconcordant and immunodiscordant individuals (85% accuracy), using markers of activation, nadir and death of CD4+ T cells. Unsupervised clustering of relevant variables using this definition revealed large heterogeneity between immunodiscordant individuals and segregated participants into three distinct subgroups with distinct production, programmed cell-death protein-1 (PD-1) expression, activation and death of T cells. Surprisingly, a nonnegligible number of immunodiscordant participants (22%) showed high frequency of recent thymic emigrants and low CD4+ T-cell activation and death, very similar to immunoconcordant participants. Notably, human leukocyte antigen - antigen D related (HLA-DR) PD-1 and CD45RA expression in CD4+ T cells allowed reproducing subgroup segregation (81.4% accuracy). Despite sharp immunological differences, similar and persistently low CD4+ values were maintained in these participants over time. Conclusion: A cutoff value of CD4+ T-cell count 400 cells/μl classified better immunodiscordant and immunoconcordant individuals than any ΔCD4 classification. Immunodiscordance may present several, even opposite, immunological patterns that are identified by a simple immunological follow-up. Subgroup classification may help clinicians to delineate diverse approaches that may be needed to boost CD4+ T-cell recovery. PMID:27427875
NASA Astrophysics Data System (ADS)
Huffman, James Douglas
2001-11-01
The most important issue facing the future business success of the Digital Micromirror Device or DMD™ produced by Texas Instruments is the cost of the actual device. As the business and consumer markets call for higher resolution displays, the array size will have to be increased to incorporate more pixels. The manufacturing costs associated with building these higher resolution displays follow an exponential relation with the number of pixels due to yield loss and reduced number of chips per silicon wafer. Each pixel is actuated by electrostatics that are provided by a memory cell that is built in the underlying silicon substrate. One way to decrease cost of the wafer is to change the memory cell architecture from a static random access configuration or SRAM to a dynamic random access configuration or DRAM. This change has the benefits of having fewer components per area and a lower metal density. This reduction in the component count and metal density has a dramatic effect on the yield of the memory array by reducing the particle sensitivity of the underlying cell. The main drawback to using a DRAM configuration in a display application is the light sensitivity of a charge storage device built in the silicon substrate. As the photons pass through the mechanical micromirrors and illuminate the DRAM cell, the effective electrostatic potential of the memory element used for the mirror actuation is reduced. This dissertation outlines the issues associated with the light sensitivity of a DRAM memory cell as the actuation element for a micromirror. The concept of charge depletion on a silicon capacitor due to recombination of photogenerated carriers is explored and experimentally verified. The effects of the reduced potential on the capacitor on the micromirror are also explored. Optical modeling is used to determine the incoming photon flux to determine the benefits of adding a charge recombination region as part of the DRAM memory cell. Several options are explored to reduce the effect of the incoming photons on the potential of the memory cell. The results will show that a 1T1C memory cell with N-type recombination regions and maximum light shielding is sufficient for a projector application.
Low white blood cell count and cancer
Neutropenia and cancer; Absolute neutrophil count and cancer; ANC and cancer ... A person with cancer can develop a low WBC count from the cancer or from treatment for the cancer. Cancer may be in ...
Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.
Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo
2017-10-07
An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.
Maestro, M. Luisa; Gómez-España, Auxiliadora; Rivera, Fernando; Valladares, Manuel; Massuti, Bartomeu; Benavides, Manuel; Gallén, Manuel; Marcuello, Eugenio; Abad, Albert; Arrivi, Antonio; Fernández-Martos, Carlos; González, Encarnación; Tabernero, Josep M.; Vidaurreta, Marta; Aranda, Enrique; Díaz-Rubio, Eduardo
2012-01-01
Background. The Maintenance in Colorectal Cancer trial was a phase III study to assess maintenance therapy with single-agent bevacizumab versus bevacizumab plus chemotherapy in patients with metastatic colorectal cancer. An ancillary study was conducted to evaluate the circulating tumor cell (CTC) count as a prognostic and/or predictive marker for efficacy endpoints. Patients and Methods. One hundred eighty patients were included. Blood samples were obtained at baseline and after three cycles. CTC enumeration was carried out using the CellSearch® System (Veridex LLC, Raritan, NJ). Computed tomography scans were performed at cycle 3 and 6 and every 12 weeks thereafter for tumor response assessment. Results. The median progression-free survival (PFS) interval for patients with a CTC count ≥3 at baseline was 7.8 months, versus the 12.0 months achieved by patients with a CTC count <3 (p = .0002). The median overall survival (OS) time was 17.7 months for patients with a CTC count ≥3, compared with 25.1 months for patients with a lower count (p = .0059). After three cycles, the median PFS interval for patients with a low CTC count was 10.8 months, significantly longer than the 7.5 months for patients with a high CTC count (p = .005). The median OS time for patients with a CTC count <3 was significantly longer than for patients with a CTC count ≥3, 25.1 months versus 16.2 months, respectively (p = .0095). Conclusions. The CTC count is a strong prognostic factor for PFS and OS outcomes in metastatic colorectal cancer patients. PMID:22643538
McKenzie, Erica C; Tornquist, Susan J; Gorman, M Elena; Cebra, Christopher K; Payton, Mark E
2008-06-01
To determine the effects of SC administration of filgrastim on cell counts in venous blood and bone marrow of healthy adult alpacas. 10 healthy alpacas. Alpacas were randomly assigned to receive treatment with filgrastim (5 microg/kg, SC; n=5) or an equivalent volume of physiologic saline (0.9% NaCl) solution (5) once a day for 3 days. Blood samples were obtained via jugular venipuncture 1 day prior to treatment and once a day for 5 days commencing 24 hours after the first dose was administered. Complete blood counts were performed for each blood sample. Bone marrow aspirates were obtained from the sternum of each alpaca 48 hours before the first treatment was administered and 72 hours after the third treatment was administered. Myeloid-to-erythroid cell (M:E) ratio was determined via cytologic evaluation of bone marrow aspirates. In filgrastim-treated alpacas, substantial increases in counts of WBCs and neutrophils were detected within 24 hours after the first dose was administered. Band cell count and percentage significantly increased 24 hours after the second dose. Counts of WBCs, neutrophils, and band cells remained high 48 hours after the third dose. Red blood cell counts and PCV were unaffected. The M:E ratio also increased significantly after treatment with filgrastim. Filgrastim induced rapid and substantial increases in numbers of circulating neutrophils and M:E ratios of bone marrow in healthy alpacas. Therefore, filgrastim may be useful in the treatment of camelids with impaired bone marrow function.
Quan, Li; Ishikawa, Takaki; Michiue, Tomomi; Li, Dong-Ri; Zhao, Dong; Yoshida, Chiemi; Chen, Jian-Hua; Komatsu, Ayumi; Azuma, Yoko; Sakoda, Shigeki; Zhu, Bao-Li; Maeda, Hitoshi
2009-04-01
To investigate hematological and serum protein profiles of cadaveric heart blood with regard to the cause of death, serial forensic autopsy cases (n=308, >18 years of age, within 48 h postmortem) were examined. Red blood cells (Rbc), hemoglobin (Hb), platelets (Plt), white blood cells (Wbc), total protein (TP) and albumin (Alb) were examined in bilateral cardiac blood. Blood cell counts, collected after turning the bodies at autopsy, approximated to the clinical values. Postmortem changes were not significant for these markers. In non-head blunt injury cases, Rbc counts, Hb, TP and Alb levels in bilateral cardiac blood were lower in subacute deaths (survival time, 1-12 h) than in acute deaths (survival time <1 h). Wbc counts of left cardiac blood were significantly higher for non-head injury than for head injury in subacute deaths. In fire fatality cases, Plt count was markedly higher with an automated hematology analyzer than by using a blood smear test, suggesting Rbc fragmentation caused by deep burns, while increases in Wbc count and decreases in Alb levels were seen for subacute deaths. For asphyxiation, Rbc count, Hb, TP and Alb levels in bilateral cardiac blood were higher than other groups, and TP and Alb levels in the right cardiac blood were higher for hanging than for strangulation. These findings suggest that analyses of blood cells and proteins are useful for investigating the cause of death.
NASA Astrophysics Data System (ADS)
Wilson, Jolaine M.; Krigsfeld, Gabriel S.; Sanzari, Jenine K.; Wagner, Erika B.; Mick, Rosemarie; Kennedy, Ann R.
2012-01-01
Animal models are frequently used to assist in the determination of the long- and short-term effects of space flight. The space environment, including microgravity, can impact many physiological and immunological system parameters. It has been found that ground based models of microgravity produce changes in white blood cell counts, which negatively affects immunologic function. As part of the Center of Acute Radiation Research (CARR), we compared the acute effects on white blood cell parameters induced by the more traditionally used animal model of hindlimb unloading (HU) with a recently developed reduced weightbearing analog known as partial weight suspension (PWS). Female ICR mice were either hindlimb unloaded or placed in the PWS system at 16% quadrupedal weightbearing for 4 h, 1, 2, 7 or 10 days, at which point complete blood counts were obtained. Control animals (jacketed and non-jacketed) were exposed to identical conditions without reduced weightbearing. Results indicate that significant changes in total white blood cell (WBC), neutrophil, lymphocyte, monocyte and eosinophil counts were observed within the first 2 days of exposure to each system. These differences in blood cell counts normalized by day 7 in both systems. The results of these studies indicate that there are some statistically significant changes observed in the blood cell counts for animals exposed to both the PWS and HU simulated microgravity systems.
Casale, Teodorico; Sacco, Carmina; Ricci, Serafino; Loreti, Beatrice; Pacchiarotti, Alessandro; Cupelli, Vincenzo; Arcangeli, Giulio; Mucci, Nicola; Antuono, Vittorio; De Marco, Federica; Tomei, Gianfranco; Tomei, Francesco; Rosati, Maria Valeria
2016-06-01
Few studies in the literature have examined the effects of benzene on blood cells. The aim of this study was to evaluate the possible correlation between the blood benzene levels and the blood cell counts. From a population of 2658 workers, we studied a group of 215 subjects. Each worker underwent blood sampling for the assessment of the blood benzene levels and the blood cell counts. The Mann-Whitney U test for two-mode variables and the Kruskal-Wallis test for more-than-two-mode variables were performed on all subjects. We estimated the Pearson correlation index between the variables in the total sample and the subgroups divided according to sex, the smoking habit, and job. After the main confounding factors were evaluated, multiple linear regression was performed on both the total sample and the subgroups. A significant inverse correlation was found among the blood benzene levels and the white blood cells, lymphocytes, and neutrophils in traffic policemen, motorcyclists, and other outdoor workers. We did not find any significant correlation with any other parameters of blood cell count. Our results, which must be considered preliminary, indicate that increased blood benzene levels in outdoor workers lead to decreased counts of white blood cells, neutrophils, and lymphocytes, because of possible immune effects. These are worth investigating in the future by specific immune tests. Copyright © 2016. Published by Elsevier Ltd.
A prospective study of marine phytoplankton and reported ...
BACKGROUND: Blooms of marine phytoplankton may adversely affect human health. The potential public health impact of low-level exposures is not well established, and few prospective cohort studies of recreational exposures to marine phytoplankton have been conducted.OBJECTIVE: We evaluated the association between phytoplankton cell counts and subsequent illness among recreational beachgoers.METHODS:We recruited beachgoers at Boquer6n Beach, Puerto Rico, during the summer of 2009. We conducted interviews at three time points to assess baseline health, water activities, and subsequent illness. Daily water samples were quantitatively assayed for phytoplankton cell count. Logistic regression models, adjusted for age and sex, were used to assess the association between exposure to three categories of phytoplankton concentration and subsequent illness.RESULTS: During 26 study days, 15,726 individuals successfully completed all three interviews. Daily total phytoplankton cell counts ranged from 346 to 2,012 cells/ml (median, 712 cells/ml). The category with the highest (≥75th percentile) total phytoplankton cell count was associated with eye irritation [adjusted odds ratio (OR) = 1.30; 95% confidence interval (Cl): 1.01, 1.66], rash (OR = 1.27; 95% Cl: 1.02, 1.57), and earache (OR = 1.25; 95% Cl: 0.88, 1.77). In phytoplankton group-specific analyses, the category with the highest Cyanobacteria counts was associated with respiratory illness (OR = 1.37; 95% Cl: 1.12, 1
Koop, G; Dik, N; Nielen, M; Lipman, L J A
2010-06-01
The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Mäkelä, Mika J; Christensen, Helene Nordahl; Karlsson, Antti; Rastogi, Sarang; Kettunen, Kirsi
2018-01-01
Background : Eosinophilic airway inflammation is common in asthma patients and appears to be associated with severe exacerbations and loss of asthma control. Objective : To describe the resource utilization and clinical characteristics of patients with eosinophilic asthma. Design : Asthma patients ≥18 years with ≥1 blood eosinophil count in secondary care (South West Finland) during 2003‒2013 were included. Clinical characteristics (age, lung function, body mass index, and comorbidities) and asthma-related resource utilization (hospital admissions, outpatient visits, and emergency room [ER] visits) were retrieved. Resource utilization rates were compared for patients with blood eosinophil ≤ or >300 cells/μL, using adjusted negative binomial regression models. Results : Overall, 4,357 eligible patients were identified (mean age 60 years, females 68%), of which 1,927 (44%) had >300 eosinophil cells/μL blood. Patients with ≤300 and >300 eosinophil counts, exhibited similar clinical characteristics, including advanced age, poor lung function, and overweight. Comorbidities such as pneumonia, sinusitis, and nasal polyps, were more frequent among those with >300 eosinophil cells/μL blood compared with patients with lower counts. Eosinophil counts >300 cells/μL were associated with greater hospital admissions (rate ratio [RR] [95% confidence interval CI]: 1.13 [1.02;1.24]) and outpatient visits (RR [95% CI]: 1.11 [1.03;1.20]) compared with patients with lower eosinophil counts. Rates of ER visits were similar between the patient groups (RR [95% CI]: 0.99 [0.87;1.12]). Conclusions : Hospital admissions and outpatient visits occurred more often for patients with eosinophil counts >300 cells/µL, than for patients with lower eosinophil counts. Routine blood eosinophil screening might be useful to identify patients with an eosinophilic phenotype eligible for more targeted treatments.
Sadeghi, Leila; Moallemi, Samaneh; Tabatabai, Reza Adl; Esmaeilzadeh, Ali; Ahsani-Nasab, Sara; Ahmadi, Niloofar Eghbal; Bayanolhagh, Saeed; Lolaie, Mahin; Narouei, Arsalan; Alinaghi, Ahmad; Mohraz, Minoo
2018-01-07
The initial ART regimens used by most national treatment guidelines in resource-limited settings include 2 nucleoside reverse-transcriptase inhibitors (NRTIs) and 1 non-nucleoside reverse-transcriptase inhibitor (NNRTI). The NRTIshave consistedof Zidovudine (AZT) or Stavudine (d4T) with Lamivudine (3TC); the NNRTI component hasbeen Nevirapine (NVP) or Efavirenz (EFV). There exists few data indicating if Vonavir is more effective in increasing CD4+ T cell counts or other first-line drugs of ART.Immunological outcomes of 134 individuals who just started antiretroviral therapy with Vonavir or Zidovudine/Lamivudine and Efavirenzanalyzed. Immunological response was then assessed during 28 weeks and indicated significant CD4+ T cell increase in both groups. The increase in CD4+ T cell counts was greater in Zidovudine/Lamivudine and Efavirenz treated group. A rapid CD4+ T cell increase occurred after the first 12 weeks of therapy in Vonavir treated group with initial CD4+ T cell counts ≤100 despite the individuals with higher CD4+ T cell counts. As previous studies, we observed the noticeable increase rate of CD4+ Tcells is in the first three months of therapy. A rapid CD4+ Tcell increase occurred shortly after beginning anti retroviraltherapy using either Vonaviror Zidovudine/Lamivudine and Efavirenz. Late increases in CD4+ T cell counts are more pronounced in therapy using Zidovudine/Lamivudine and Efavirenz. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
High Count-Rate Study of Two TES X-Ray Microcalorimeters With Different Transition Temperatures
NASA Technical Reports Server (NTRS)
Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.;
2017-01-01
We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures T(sub c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T(sub c)(sup s) had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.eV at 6 keV from lower and higher T(sub c) devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the socalled event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96 Percent throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T(sub c) (faster) device, and 5.8 eV FWHM with 97 Percent throughput with the lower T(sub c) (slower) device at 722 Hz.
Lewis, Joanna; Walker, A Sarah; Castro, Hannah; De Rossi, Anita; Gibb, Diana M; Giaquinto, Carlo; Klein, Nigel; Callard, Robin
2012-02-15
Effective therapies and reduced AIDS-related morbidity and mortality have shifted the focus in pediatric human immunodeficiency virus (HIV) from minimizing short-term disease progression to maintaining optimal long-term health. We describe the effects of children's age and pre-antiretroviral therapy (ART) CD4 count on long-term CD4 T-cell reconstitution. CD4 counts in perinatally HIV-infected, therapy-naive children in the Paediatric European Network for the Treatment of AIDS 5 trial were monitored following initiation of ART for a median 5.7 years. In a substudy, naive and memory CD4 counts were recorded. Age-standardized measurements were analyzed using monophasic, asymptotic nonlinear mixed-effects models. One hundred twenty-seven children were studied. Older children had lower age-adjusted CD4 counts in the long term and at treatment initiation (P < .001). At all ages, lower counts before treatment were associated with impaired recovery (P < .001). Age-adjusted naive CD4 counts increased on a timescale comparable to overall CD4 T-cell reconstitution, whereas age-adjusted memory CD4 counts increased less, albeit on a faster timescale. It appears the immature immune system can recover well from HIV infection via the naive pool. However, this potential is progressively damaged with age and/or duration of infection. Current guidelines may therefore not optimize long-term immunological health.
Hsu, Wan-Ling; Tatsukawa, Yoshimi; Neriishi, Kazuo; Yamada, Michiko; Cologne, John; Fujiwara, Saeko
2010-01-01
In studying the late health effects of atomic-bomb (A-bomb) survivors, earlier findings were that white blood cell (WBC) count increased with radiation dose in cross-sectional studies. However, a persistent effect of radiation on WBC count and other risk factors has yet to be confirmed. The objectives of the present study were 1) to examine the longitudinal relationship between A-bomb radiation dose and WBC and differential WBC counts among A-bomb survivors and 2) to investigate the potential confounding risk factors (such as age at exposure and smoking status) as well as modification of the radiation dose-response. A total of 7,562 A-bomb survivors in Hiroshima and Nagasaki were included in this study from 1964-2004. A linear mixed model was applied using the repeated WBC measurements. During the study period, a secular downward trend of WBC count was observed. Radiation exposure was a significant risk factor for elevated WBC and differential WBC counts over time. A significant increase of WBC counts among survivors with high radiation dose (> 2 Gy) was detected in men exposed below the age of 20 and in women regardless of age at exposure. Effects on WBC of low dose radiation remain unclear, however. Cigarette smoking produced the most pronounced effect on WBC counts and its impact was much larger than that of radiation exposure.
Ayoade, Folusakin; Todd, John; Al-Delfi, Firas; King, John
2017-10-01
Toxoplasmosis is an important cause of enhancing brain lesions in patients with acquired immunodeficiency syndrome (AIDS), and it is typically associated with low CD4-lymphocyte counts. Extensive toxoplasma encephalitis when the CD4-lymphocyte count is above 100 cells/µl is unusual. Cavitary lung lesions are also not typically associated with toxoplasmosis. Here, we present a case of toxoplasmosis associated with extensive brain masses and cavitary lung lesions, both of which improved with directed toxoplasmosis therapy, in an AIDS patient with a CD4 cell count of 120 cells/µl.
High-Throughput Quantification of Bacterial-Cell Interactions Using Virtual Colony Counts
Hoffmann, Stefanie; Walter, Steffi; Blume, Anne-Kathrin; Fuchs, Stephan; Schmidt, Christiane; Scholz, Annemarie; Gerlach, Roman G.
2018-01-01
The quantification of bacteria in cell culture infection models is of paramount importance for the characterization of host-pathogen interactions and pathogenicity factors involved. The standard to enumerate bacteria in these assays is plating of a dilution series on solid agar and counting of the resulting colony forming units (CFU). In contrast, the virtual colony count (VCC) method is a high-throughput compatible alternative with minimized manual input. Based on the recording of quantitative growth kinetics, VCC relates the time to reach a given absorbance threshold to the initial cell count using a series of calibration curves. Here, we adapted the VCC method using the model organism Salmonella enterica sv. Typhimurium (S. Typhimurium) in combination with established cell culture-based infection models. For HeLa infections, a direct side-by-side comparison showed a good correlation of VCC with CFU counting after plating. For MDCK cells and RAW macrophages we found that VCC reproduced the expected phenotypes of different S. Typhimurium mutants. Furthermore, we demonstrated the use of VCC to test the inhibition of Salmonella invasion by the probiotic E. coli strain Nissle 1917. Taken together, VCC provides a flexible, label-free, automation-compatible methodology to quantify bacteria in in vitro infection assays. PMID:29497603
Intestinal parasitic infections in relation to HIV/AIDS status, diarrhea and CD4 T-cell count.
Assefa, Shimelis; Erko, Berhanu; Medhin, Girmay; Assefa, Zelalem; Shimelis, Techalew
2009-09-18
HIV infection has been modifying both the epidemiology and outcome of parasitic infections. Hence, this study was undertaken to determine the prevalence of intestinal parasitic infection among people with and without HIV infection and its association with diarrhea and CD4 T-cell count. A cross-sectional study was conducted at Hawassa Teaching and Referral Hospital focusing on HIV positive individuals, who gave blood for CD4 T-cell count at their first enrollment and clients tested HIV negative from November, 2008 to March, 2009. Data on socio-demographic factors and diarrhea status were obtained by interviewing 378 consecutive participants (214 HIV positive and 164 HIV negative). Stool samples were collected from all study subjects and examined for parasites using direct, formol-ether and modified acid fast stain techniques. The prevalence of any intestinal parasitic infection was significantly higher among HIV positive participants. Specifically, rate of infection with Cryptosporidium, I. belli, and S. stercoralis were higher, particularly in those with CD4 count less than 200 cells/microL. Diarrhea was more frequent also at the same lower CD4 T-cell counts. Immunodeficiency increased the risk of having opportunistic parasites and diarrhea. Therefore; raising patient immune status and screening at least for those treatable parasites is important.
A Structure Memory for Data Flow Computers
1977-09-01
with a FET+ before the result is sent to the destination cells. If one of those cells is a SELECT that issues a FET- to reduce the refe- ence count, the...it.in a lAD packet through lADO . Since a reference count scheme is used for recovering unused cells, the controller watches for words whose reference
Occupational exposure to formaldehyde and alterations in lymphocyte subsets
Hosgood, H. Dean; Zhang, Luoping; Tang, Xiaojiang; Vermeulen, Roel; Hao, Zhenyue; Shen, Min; Qiu, Chuangyi; Ge, Yichen; Hua, Ming; Ji, Zhiying; Li, Senhua; Xiong, Jun; Reiss, Boris; Liu, Songwang; Xin, Kerry X.; Azuma, Mariko; Xie, Yuxuan; Freeman, Laura Beane; Ruan, Xiaolin; Guo, Weihong; Galvan, Noe; Blair, Aaron; Li, Laiyu; Huang, Hanlin; Smith, Martyn T.; Rothman, Nathaniel; Lan, Qing
2012-01-01
Background Formaldehyde is used in many occupational settings, most notably in manufacturing, health care, and embalming. Formaldehyde has been classified as a human carcinogen, but its mechanism of action remains uncertain. Methods We carried out a cross-sectional study of 43 formaldehyde exposed-workers and 51 unexposed age and sex-matched controls in Guangdong, China to study formaldehyde’s early biologic effects. To follow-up our previous report that the total lymphocyte count was decreased in formaldehyde-exposed workers compared to controls, we evaluated each major lymphocyte subset (i.e., CD4+ T cells, CD8+ T cells, natural killer (NK) cells, and B cells) and T cell lymphocyte subset (CD4+ naïve and memory T cells, CD8+ naïve and memory T cells, and regulatory T cells). Linear regression of each subset was used to test for differences between exposed workers and controls, adjusting for potential confounders. Results Total NK cell and T cell counts were about 24% (p=0.037) and 16% (p=0.0042) lower, respectively, among exposed workers. Among certain T cell subsets, decreased counts among exposed workers were observed for CD8+ T cells (p=0.026), CD8+ effector memory T cells (p=0.018), and regulatory T cells (CD4+FoxP3+: p=0.04; CD25+FoxP3+: p=0.008). Conclusions Formaldehyde exposed-workers experienced decreased counts of NK cells, regulatory T cells, and CD8+ effector memory T cells; however, due to the small sample size these findings need to be confirmed in larger studies. PMID:22767408
Zugaza, J L; Casabiell, X A; Bokser, L; Eiras, A; Beiras, A; Casanueva, F F
1995-07-01
We have previously demonstrated that pretreatment of several cell lines with cis-unsaturated fatty acids, like oleic acid, blocks epidermal growth factor (EGF)-induced early ionic signals, and in particular the [Ca2+]i rise. In the present work we show that this blockade does not alter EGF-stimulated cellular proliferation evaluated by direct cell counting, but induces a powerful enhancement in the pulsed thymidine incorporation assay. The lack of effect of oleic acid on EGF-stimulated cellular proliferation was confirmed by repeated cell counts, cumulative thymidine incorporation, and protein synthesis, but a clear synergistic effect between oleic acid and EGF was again obtained by means of time course experiments with pulsed thymidine. Combined flow cytometry analysis and cell counts at earlier times in EGF-stimulated cells showed that oleic acids accelerates the entrance of cells into the replicative cycle leading to an earlier cell division. Afterward, these oleic acid-pretreated cells became delayed by an unknown compensatory mechanism in such a way that at 48 h post-EGF, the cell count in control and oleic acid-pretreated cells was equal. In conclusion (a) oleic acid accelerates or enhances the EGF mitogenic action and (b) in the long term cells compensate the initial perturbation with respect to untreated cells. As a side observation, the widely employed pulsed thymidine incorporation method as a measure of cell division could be extremely misleading unless experimental conditions are well controlled.
2012-01-01
Background The risk of HIV-1 related mortality is strongly related to CD4 count. Guidance on optimal timing for initiation of antiretroviral therapy (ART) is still evolving, but the contribution of HIV-1 infection to excess mortality at CD4 cell counts above thresholds for HIV-1 treatment has not been fully described, especially in resource-poor settings. To compare mortality among HIV-1 infected and uninfected members of HIV-1 serodiscordant couples followed for up to 24 months, we conducted a secondary data analysis examining mortality among HIV-1 serodiscordant couples participating in a multicenter, randomized controlled trial at 14 sites in seven sub-Saharan African countries. Methods Predictors of death were examined using Cox regression and excess mortality by CD4 count and plasma HIV-1 RNA was computed using Poisson regression for correlated data. Results Among 3295 HIV serodiscordant couples, we observed 109 deaths from any cause (74 deaths among HIV-1 infected and 25 among HIV-1 uninfected persons). Among HIV-1 infected persons, the risk of death increased with lower CD4 count and higher plasma viral levels. HIV-1 infected persons had excess mortality due to medical causes of 15.2 deaths/1000 person years at CD4 counts of 250 – 349 cells/μl and 8.9 deaths at CD4 counts of 350 – 499 cells/μl. Above a CD4 count of 500 cells/μl, mortality was comparable among HIV-1 infected and uninfected persons. Conclusions Among African serodiscordant couples, there is a high rate of mortality attributable to HIV-1 infection at CD4 counts above the current threshold (200 – 350 cells/μl) for ART initiation in many African countries. These data indicate that earlier initiation of treatment is likely to provide clinical benefit if further expansion of ART access can be achieved. Trial Registration Clinicaltrials.gov (NCT00194519) PMID:23130818
Does corneal hysteresis correlate with endothelial cell density?
Akova-Budak, Berna; Kıvanç, Sertaç Argun
2015-05-21
Our aim was to determine if there is a correlation between corneal biomechanical properties, endothelial cell count, and corneal pachymetry in healthy corneas. Ninety-two eyes of all subjects underwent complete ocular examination, including intraocular pressure measurement by Goldmann applanation tonometer, objective refraction, and slit-lamp biomicroscopy. Topographic measurements and corneal pachymetry were performed using a Scheimpflug-based (Pentacam, Oculus, Germany) corneal topographer. Corneal hysteresis (CH) and corneal resistance factor (CRF) were measured with an Ocular Response Analyzer (ORA, Reichert Ophthalmic Instruments, Buffalo, NY). Endothelial cell count measurement was done using a specular microscope (CellChek, Konan, USA). Right eye values of the subjects were taken for the study. The mean CH was 11.5±1.7 mmHg and the mean CRF was 11.2±1.4 mmHg. Mean intraocular pressure was 15.3±2.3 mmHg. The mean endothelial cell count was 2754±205 cells/mm2. No correlation was found between biomechanical properties of cornea and endothelial cell count. There was a significant positive correlation between CH, CRF, and corneal thickness (p<0.001; r=0.79). The corneal biomechanical properties significantly correlated with corneal thickness. We found no correlation between CH and CRF with the endothelial cell density in normal subjects.
Cora, Michelle C; Neel, Jennifer A; Grindem, Carol B; Kissling, Grace E; Hess, Paul R
2013-06-01
To determine the frequency of clinically relevant abnormalities missed by failure to perform a blood smear evaluation in a specific subset of dogs receiving chemotherapy and to compare automated and manual neutrophil counts in the same population. Retrospective case series. 50 dogs receiving chemotherapy with a total nucleated cell count > 4,000 nucleated cells/μL. 50 blood smears were evaluated for abnormalities that have strong potential to change the medical plan for a patient: presence of blast cells, band neutrophils, nucleated RBCs, toxic change, hemoparasites, schistocytes, and spherocytes. Automated and manual neutrophil counts were compared. Blood smears from 10 (20%) patients had ≥ 1 abnormalities. Blast cells were identified on 4 (8%) blood smears, increased nucleated RBCs were identified on 5 (10%), and very mild toxic change was identified on 2 (4%). Correlation coefficient of the neutrophil counts was 0.96. Analysis revealed a slight bias between the automated and manual neutrophil counts (mean ± SD difference, -0.43 × 10(3)/μL ± 1.10 × 10(3)/μL). In this series of patients, neutrophil count correlation was very good. Clinically relevant abnormalities were found on 20% of the blood smears. An automated CBC appears to be accurate for neutrophil counts, but a microscopic examination of the corresponding blood smear is still recommended; further studies are needed to determine whether the detection or frequency of these abnormalities would differ dependent on chemotherapy protocol, neoplastic disease, and decision thresholds used by the oncologist in the ordering of a CBC without a blood smear evaluation.
Van Rie, Annelies; Patel, Monita R; Nana, Mbonze; Vanden Driessche, Koen; Tabala, Martine; Yotebieng, Marcel; Behets, Frieda
2014-03-01
A crucial question in managing HIV-infected patients with tuberculosis (TB) concerns when and how to initiate antiretroviral therapy (ART). The effectiveness of CD4-stratified ART initiation in a nurse-centered, integrated TB/HIV program at primary care in Kinshasa, Democratic Republic of Congo, was assessed. Prospective cohort study was conducted to assess the effect of CD4-stratified ART initiation by primary care nurses (513 TB patients, August 2007 to November 2009). ART was to be initiated at 1 month of TB treatment if CD4 count is <100 cells per cubic millimeter, at 2 months if CD4 count is 100-350 cells per cubic millimeter, and at the end of TB treatment after CD4 count reassessment if CD4 count is >350 cells per cubic millimeter. ART uptake and mortality were compared with a historical prospective cohort of 373 HIV-infected TB patients referred for ART to a centralized facility and 3577 HIV-negative TB patients (January 2006 to May 2007). ART uptake increased (17%-69%, P < 0.0001) and mortality during TB treatment decreased (20.1% vs 9.8%, P < 0.0003) after decentralized, nurse-initiated, CD4-stratified ART. Mortality among TB patients with CD4 count >100 cells per cubic millimeter was similar to that of HIV-negative TB patients (5.6% vs 6.3%, P = 0.65), but mortality among those with CD4 count <100 cells per cubic millimeter remained high (18.8%). Nurse-centered, CD4-stratified ART initiation at primary care level was effective in increasing timely ART uptake and reducing mortality among TB patients but may not be adequate to prevent mortality among those presenting with severe immunosuppression. Further research is needed to determine the optimal management at primary care level of TB patients with CD4 counts <100 cells per cubic millimeter.
Misha, Mehak; Rai, Lavanya
2014-01-01
Objectives. To evaluate the effect of preeclampsia on the cord blood and maternal NRBC count and to correlate NRBC count and neonatal outcome in preeclampsia and control groups. Study Design. This is a prospective case control observational study. Patients and Methods. Maternal and cord blood NRBC counts were studied in 50 preeclamptic women and 50 healthy pregnant women. Using automated cell counter total leucocyte count was obtained and peripheral smear was prepared to obtain NRBC count. Corrected WBC count and NRBC count/100 leucocytes in maternal venous blood and in cord blood were compared between the 2 groups. Results. No significant differences were found in corrected WBC count in maternal and cord blood in cases and controls. Significant differences were found in mean cord blood NRBC count in preeclampsia and control groups (40.0 ± 85.1 and 5.9 ± 6.3, P = 0.006). The mean maternal NRBC count in two groups was 2.4 ± 9.0 and 0.8 ± 1.5, respectively (P = 0.214). Cord blood NRBC count cut off value ≤13 could rule out adverse neonatal outcome with a sensitivity of 63% and specificity of 89%. Conclusion. Cord blood NRBC are significantly raised in preeclampsia. Neonates with elevated cord blood NRBC counts are more likely to have IUGR, low birth weight, neonatal ICU admission, respiratory distress syndrome, and assisted ventilation. Below the count of 13/100 leucocytes, adverse neonatal outcome is quite less likely. PMID:24734183
Comparison of six different methods to calculate cell densities.
Camacho-Fernández, Carolina; Hervás, David; Rivas-Sendra, Alba; Marín, Mª Pilar; Seguí-Simarro, Jose M
2018-01-01
For in vitro culture of plant and animal cells, one of the critical steps is to adjust the initial cell density. A typical example of this is isolated microspore culture, where specific cell densities have been determined for different species. Out of these ranges, microspore growth is not induced, or is severely reduced. A similar situation occurs in many other plant and animal cell culture systems. Traditionally, researchers have used counting chambers (hemacytometers) to calculate cell densities, but little is still known about their technical advantages. In addition, much less information is available about other, alternative methods. In this work, using isolated eggplant microspore cultures and fluorescent beads (fluorospheres) as experimental systems, we performed a comprehensive comparison of six methods to calculate cell densities: (1) a Neubauer improved hemacytometer, (2) an automated cell counter, (3) a manual-counting method, and three flow cytometry methods based on (4) autofluorescence, (5) propidium iodide staining, and (6) side scattered light (SSC). Our results show that from a technical perspective, hemacytometers are the most reasonable option for cell counting, which may explain their widely spread use. Automated cell counters represent a good compromise between precision and affordability, although with limited accuracy. Finally, the methods based on flow cytometry were, by far, the best in terms of reproducibility and agreement between them, but they showed deficient accuracy and precision. Together, our results show a thorough technical evaluation of each counting method, provide unambiguous arguments to decide which one is the most convenient for the particular case of each laboratory, and in general, shed light into the best way to determine cell densities for in vitro cell cultures. They may have an impact in such a practice not only in the context of microspore culture, but also in any other plant cell culture procedure, or in any process involving particle counting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taneja, S; Fru, L Che; Desai, V
Purpose: It is now commonplace to handle treatments of hyperthyroidism using iodine-131 as an outpatient procedure due to lower costs and less stringent federal regulations. The Nuclear Regulatory Commission has currently updated release guidelines for these procedures, but there is still a large uncertainty in the dose to the public. Current guidelines to minimize dose to the public require patients to remain isolated after treatment. The purpose of this study was to use a low-cost common device, such as a cell phone, to estimate exposure emitted from a patient to the general public. Methods: Measurements were performed using an Applemore » iPhone 3GS and a Cs-137 irradiator. The charge-coupled device (CCD) camera on the phone was irradiated to exposure rates ranging from 0.1 mR/hr to 100 mR/hr and 30-sec videos were taken during irradiation with the camera lens covered by electrical tape. Interactions were detected as white pixels on a black background in each video. Both single threshold (ST) and colony counting (CC) methods were performed using MATLAB®. Calibration curves were determined by comparing the total pixel intensity output from each method to the known exposure rate. Results: The calibration curve showed a linear relationship above 5 mR/hr for both analysis techniques. The number of events counted per unit exposure rate within the linear region was 19.5 ± 0.7 events/mR and 8.9 ± 0.4 events/mR for the ST and CC methods respectively. Conclusion: Two algorithms were developed and show a linear relationship between photons detected by a CCD camera and low exposure rates, in the range of 5 mR/hr to 100-mR/hr. Future work aims to refine this model by investigating the dose-rate and energy dependencies of the camera response. This algorithm allows for quantitative monitoring of exposure from patients treated with iodine-131 using a simple device outside of the hospital.« less