Sample records for cementless total hip

  1. The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

    PubMed

    Russell, R C; Ghassemi, A; Dorrell, J H; Powles, D P

    2009-08-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7-18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance.

  2. The Bimetric cementless total hip replacement: 7–18 year follow-up assessing the influence of acetabular design on survivorship

    PubMed Central

    Ghassemi, A.; Dorrell, J. H.; Powles, D. P.

    2008-01-01

    The purpose of this study was to evaluate the mid- to long-term survivorship of Bimetric cementless total hip replacement and assess how it is affected by the acetabular design. This was a retrospective analysis of 127 Bimetric cementless total hip replacements in 110 patients with a follow-up of 7–18 years. A single design stem and three different cementless metal-backed acetabular designs were used. Patients were assessed clinically using the Harris hip score and radiologically by independent review of current hip radiographs. There was only one case of aseptic loosening of the femoral stem. The earliest acetabular design showed a high failure rate whilst the latter two designs showed a 96% survivorship at a mean of 9.5 years. We conclude that a combination of the bimetric stem with either of the latter acetabular cup designs has a good mid- to long-term performance. PMID:18551293

  3. An initial experience with hip resurfacing versus cementless total hip arthroplasty.

    PubMed

    Arndt, Justin Michael; Wera, Glenn D; Goldberg, Victor M

    2013-07-01

    Hip resurfacing is an alternative to total hip arthroplasty. We aimed to compare an experienced hip surgeon's initial clinical results of hip resurfacing with a new cementless total hip arthroplasty (THA). The first 55 consecutive hip resurfacing arthroplasties were compared to 100 consecutive cementless THAs using a cylindrical tapered femoral stem. The learning curve between the two procedures was compared utilizing the incidence of reoperation, complications, Harris Hip Scores (HHS), and implant survivorship. The reoperation rate was significantly higher (p = 0.019) for hip resurfacing (14.5%) versus THA (4%). The overall complication rate between the two groups was not significantly different (p = 0.398). Preoperative HHS were similar between the two groups (p = 0.2). The final mean HHS was similar in both the resurfacing and THA groups (96 vs. 98.3, respectively, p < 0.65). Kaplan-Meier survival analysis with an endpoint of reoperation suggests complications occurred earlier in the resurfacing group versus the THA group (log-rank test, p = 0.007). In comparison to our initial experience with a cementless THA stem, operative complications occur earlier and more often after hip resurfacing during the learning period. The clinical outcomes in both groups however are similar at 5 year follow-up.

  4. Long-term result of cementless femoral stem in avascular necrosis of the hip.

    PubMed

    Cheung, Kin W; Chiu, Kwok H; Chung, Kwong Y

    2015-01-01

    Avascular necrosis (AVN) of the hip may have extensive involvement of the proximal femur which may affect boney ingrowth into cementless femoral stems. From 1994 to 2004, 182 total hip arthroplasties (in 144 patients, 117 AVN hips and 65 non-AVN hips) were performed using hydroxyapatite coated femoral stems. All patients were followed up prospectively. Mean age was 51 years and mean follow-up 14.7 years (range 9.7-19.1 years). Four stems were revised because of aseptic loosening, 3 in AVN group and 1 in non-AVN group. The overall mechanical failure rate was 2.2%, the mechanical failure rate in AVN and non-AVN group was 2.6% and 1.5% respectively (p = 1). The 19.1 year survival using revision for aseptic loosening as an endpoint for AVN and non-AVN patients were 97.1% and 96.2% respectively (p = 0.654). Stable boney ingrowth was present in 99.5% hips. This study represents 1 of the largest series reporting the long-term follow-up of the use of cementless femoral stems in treating AVN of the hip. We report excellent long-term survival of cementless total hip arthroplasty used in managing AVN of the hip and is comparable to that seen in non-AVN total hip arthroplasty.

  5. Novel cemented cup-holding technique while performing total hip arthroplasty with navigation system.

    PubMed

    Takai, Hirokazu; Takahashi, Tomoki

    2017-09-01

    Recently, navigation systems have been more widely utilized in total hip arthroplasty. However, almost all of these systems have been developed for cementless cups. In the case of cemented total hip arthroplasty using a navigation system, a special-ordered cemented holder is needed. We propose a novel cemented cup-holding technique for navigation systems using readily available articles. We combine a cementless cup holder with an inverted cementless trial cup. The resulting apparatus is used as a cemented cup holder. The upside-down cup-holding technique is useful and permits cemented cup users to utilize a navigation system for placement of the acetabular component.

  6. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.

    PubMed

    Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko

    2013-03-01

    Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.

  7. Total Hip Arthroplasty in Haemophilic Patients with Modern Cementless Implants.

    PubMed

    Carulli, Christian; Felici, Irene; Martini, Caterina; Civinini, Roberto; Linari, Silvia; Castaman, Giancarlo; Innocenti, Massimo

    2015-10-01

    Hip arthropathy due to recurrent haemarthrosis in patients with haemophilia can be disabling. When severe degeneration occurs, total hip arthroplasty is indicated. Reported outcomes are variable and out of date. The aim of this study is to evaluate the survivorship of Total Hip Arthroplasty performed in a patient population with modern cementless implants. Twenty-three haemophilic patients were treated and followed by a multidisciplinary team dedicated to haemophilia. The mean age was 40.6 years. No failures or complications were recorded at a mean follow-up of 8.1 years (range: 3.1-13.7). A multidisciplinary team and the use of modern cementless implants may represent the keys to achieve good outcomes, fewer complications, and better survivorship in the approach to these difficult cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Treatment of Crowe Type-IV Hip Dysplasia Using Cementless Total Hip Arthroplasty and Double Chevron Subtrochanteric Shortening Osteotomy: A 5- to 10-Year Follow-Up Study.

    PubMed

    Li, Xigong; Lu, Yang; Sun, Junying; Lin, Xiangjin; Tang, Tiansi

    2017-02-01

    The purpose of this study was to evaluate the functional and radiographic results of patients with Crowe type-IV hip dysplasia treated by cementless total hip arthroplasty and double chevron subtrochanteric osteotomy. From January 2000 to February 2006, cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy was performed on 18 patients (22 hips) with Crowe type-IV dysplasia. The acetabular cup was placed in the position of the anatomic hip center, and subtrochanteric femoral shortening osteotomy was performed with the use of a double chevron design. The clinical and radiographic outcomes were reviewed with a mean follow-up of 6.5 years (5-10 years). The mean amount of femoral subtrochanteric shortening was 38 mm (25-60 mm). All osteotomy sites were healed by 3-6 months without complications. The mean Harris Hip Score improved significantly from 47 points (35-65 points) preoperatively to 88 points (75-97 points) at the final follow-up. The Trendelenburg sign was corrected from a positive preoperative status to a negative postoperative status in 12 of 22 hips. No acetabular and femoral components have loosened or required revision during the period of follow-up. Cementless total hip arthroplasty using double chevron subtrochanteric osteotomy allowed for restoration of anatomic hip center with safely functional limb lengthening, achieved correction of preoperative limp, and good functional and radiographic outcomes for 22 Crowe type-IV dislocation hips at the time of the 5- to 10-year follow-up. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Cementless total hip arthroplasty with a double chevron subtrochanteric shortening osteotomy in patients with Crowe type-IV hip dysplasia.

    PubMed

    Li, Xigong; Sun, Junying; Lin, Xiangjin; Xu, Sanzhong; Tang, Tiansi

    2013-06-01

    The authors describe a modified double chevron subtrochanteric shortening osteotomy combined with cementless total hip arthroplasty for Crowe type-IV hip dysplasia. Shortening the femur allows to relax the shortened musculature. This operation was performed in 18 patients (22 hips) between January 2000 and February 2006. The mean follow-up period was 5.6 years (range: 3 to 8 years). The mean amount of femoral subtrochanteric shortening was 38 mm (range: 25 to 60 mm). The mean Harris hip score improved from 47 (range: 35 to 65) preoperatively to 88 points (range: 75 to 97) at final follow-up. The Trendelenburg sign was corrected from positive to negative in 12 of 22 hips. No acetabular or femoral components loosened or required revision during the follow-up period. All osteotomy sites healed in 3 to 6 months without complications. Cementless total hip arthroplasty using the modified double chevron subtrochanteric osteotomy provided good short- to midterm results in all 22 Crowe type-IV hip dislocations. Moreover, it restored the anatomic hip center and the limb length, which contributed to correction of the preoperative limp.

  10. Changes of bone mineral density after cementless total hip arthroplasty with two different stems

    PubMed Central

    Ito, Kouji; Yamamoto, Kengo

    2007-01-01

    Cementless total hip arthroplasty has achieved reliable long-term results since porous coatings were developed, but postoperative changes around the stem remain poorly documented. In this study, changes of the bone mineral density (BMD) were compared between two types of cementless stem. In group B (28 patients with 31 hips), a straight tapered stem with porous plasma spray coating on the proximal 1/4 was used, while group S (24 patients with 26 hips) was given a fluted, tri-slot stem with porous hydroxyapatite coating on the proximal 1/3. In group B, there was an early decrease of BMD, which recovered after 12 months, indicating that stress shielding was minimal. In group S, however, BMD continued to decrease without recovery. The stem shape and radiological findings suggested that the cause of stress shielding in group S was distal fixation. PMID:17225187

  11. The cost analysis of cemented versus cementless total hip replacement operations on the NHS.

    PubMed

    Kallala, R; Anderson, P; Morris, S; Haddad, F S

    2013-07-01

    In a time of limited resources, the debate continues over which types of hip prosthesis are clinically superior and more cost-effective. Orthopaedic surgeons increasingly need robust economic evidence to understand the full value of the operation, and to aid decision making on the 'package' of procedures that are available and to justify their practice beyond traditional clinical preference. In this paper we explore the current economic debate about the merits of cemented and cementless total hip replacement, an issue that continues to divide the orthopaedic community.

  12. Neck fracture of a cementless forged titanium alloy femoral stem following total hip arthroplasty: a case report and review of the literature

    PubMed Central

    Grivas, Theodoros B; Savvidou, Olga D; Psarakis, Spyridon A; Bernard, Pierre-Francois; Triantafyllopoulos, George; Kovanis, Ioannis; Alexandropoulos, Panagiotis

    2007-01-01

    Introduction Fractures of the neck of the femoral component have been reported in uncemented total hip replacements, however, to our knowledge, no fractures of the neck of a cementless forged titanium alloy femoral stem coated in the proximal third with hydroxy-apatite have been reported in the medical literature. Case presentation This case report describes a fracture of the neck of a cementless forged titanium alloy stem coated in the proximal third with hydroxy-apatite. Conclusion The neck of the femoral stem failed from fatigue probably because of a combination of factors described analytically below. PMID:18062807

  13. Outcome after cementless total hip arthroplasty for arthritic hip in patients with residual poliomyelitis: a case series.

    PubMed

    Cho, Yoon J; Lee, Choong H; Chun, Young S; Rhyu, Kee H

    2016-09-29

    In this case series, we investigated the outcome of cementless total hip arthroplasty (THA) for advanced hip osteoarthritis in patients with residual poliomyelitis to evaluate its clinical usefulness for these patients. 11 unilateral cementless primary THA were performed to arthritic hips in patients with residual poliomyelitis. 7 were in paralytic and 4 were in nonparalytic limbs. The mean follow-up duration was 79.9 months. Retrospective clinical evaluations with various scores and radiological evaluations were made. Harris Hip Score, Western Ontario and McMaster Universities Arthritis Index (WOMAC) and Short-form (SF)-36 physical scales were significantly improved after the surgery. However, UCLA activity score and SF-36 mental scale were not. Because of remaining leg length discrepancies, all but 1 noted a residual limp. In nonparalytic hip, functional acetabular cup inclination during weight bearing significantly increased from installed inclination. Other than 1 case of posterior dislocation, no complications were observed. Although the overall result itself is excellent, THA for these patients cannot improve limp, physical activity and mental status. Surgeons should be aware of the change of the inclination of acetabular cup during mobilisation, especially for THA in contralateral hip.

  14. A Multicenter Approach Evaluating the Impact of Vitamin E-Blended Polyethylene in Cementless Total Hip Replacement

    PubMed Central

    Jäger, Marcus; van Wasen, Andrea; Warwas, Sebastian; Landgraeber, Stefan; Haversath, Marcel; Group, VITAS

    2014-01-01

    Since polyethylene is one of the most frequently used biomaterials as a liner in total hip arthroplasty, strong efforts have been made to improve design and material properties over the last 50 years. Antioxidants seems to be a promising alternative to further increase durability and reduce polyethylene wear in long term. As of yet, only in vitro results are available. While they are promising, there is yet no clinical evidence that the new material shows these advantages in vivo. To answer the question if vitamin-E enhanced ultra-high molecular weight polyethylene (UHMWPE) is able to improve long-term survivorship of cementless total hip arthroplasty we initiated a randomized long-term multicenter trial. Designed as a superiority study, the oxidation index assessed in retrieval analyses of explanted liners was chosen as primary parameter. Radiographic results (wear rate, osteolysis, radiolucency) and functional outcome (Harris Hip Scores, University of California-Los Angeles, Hip Disability and Osteoarthritis Outcome Score, Visual Analogue Scale) will serve as secondary parameters. Patients with the indication for a cementless total hip arthroplasty will be asked to participate in the study and will be randomized to either receive a standard hip replacement with a highly cross-linked UHMWPE-X liner or a highly cross-linked vitamin-E supplemented UHMWPE-XE liner. The follow-up will be 15 years, with evaluation after 5, 10 and 15 years. The controlled randomized study has been designed to determine if Vitamin-E supplemented highly cross-linked polyethylene liners are superior to standard XLPE liners in cementless total hip arthroplasty. While several studies have been started to evaluate the influence of vitamin-E, most of them evaluate wear rates and functional results. The approach used for this multicenter study, to analyze the oxidation status of retrieved implants, should make it possible to directly evaluate the ageing process and development of the implant material itself over a time period of 15 years. PMID:25002933

  15. Biomechanical evaluation of adjunctive cerclage wire fixation for the prevention of periprosthetic femur fractures using cementless press-fit total hip replacement.

    PubMed

    Christopher, Scott A; Kim, Stanley E; Roe, Simon; Pozzi, Antonio

    2016-08-01

    Periprosthetic femoral fractures are a common complication associated with cementless press-fit total hip arthroplasty. The use of prophylactic cerclage wire fixation has been advocated to reduce this complication. The objective of this study was to evaluate whether a double loop cerclage wire, used as adjunctive fixation, increased the peak torsional load to failure in femora implanted with press-fit cementless stems. Peak torsional load to failure was compared between femora without adjunctive fixation and femora receiving a 1 mm double loop cerclage wire placed proximally to the lesser trochanter. Femora treated with adjunctive cerclage wire fixation failed at 20% greater peak torque (P = 0.0001). In conclusion, a double loop cerclage wire may aid in the prevention of periprosthetic fractures associated with press-fit cementless femoral stems. Copyright © 2016. Published by Elsevier Ltd.

  16. Intraoperative Proximal Femoral Fracture in Primary Cementless Total Hip Arthroplasty.

    PubMed

    Ponzio, Danielle Y; Shahi, Alisina; Park, Andrew G; Purtill, James J

    2015-08-01

    Intraoperative proximal femoral fracture is a complication of primary cementless total hip arthroplasty (THA) at rates of 2.95-27.8%. A retrospective review of 2423 consecutive primary cementless THA cases identified 102 hips (96 patients) with fracture. Multivariate analysis compared fracture incidences between implants, Accolade (Stryker Orthopaedics) and Tri-Lock (DePuy Orthopaedics, Inc.), and evaluated potential risk factors using a randomized control group of 1150 cases without fracture. The fracture incidence was 4.4% (102/2423), 3.7% (36/1019) using Accolade and 4.9% using Tri-Lock (66/1404) (P=0.18). Female gender (OR=1.96; 95% CI 1.19-3.23; P=0.008) and smaller stem size (OR=1.64; 95% CI 1.04-2.63; P=0.03) predicted increased odds of fracture. No revisions of the femoral component were required in the fracture cohort. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Hot topics and controversies in arthroplasty: cementless femoral fixation in elderly patients.

    PubMed

    Dutton, Andrew; Rubash, Harry E

    2008-01-01

    Cementless femoral fixation has been established as the gold standard for hip arthroplasty in young patients because of its exceptional longevity. Because older Americans are living longer and staying active, cementless femoral fixation for hip arthroplasty should be considered in all patients who have good bone quality. Numerous studies have shown excellent results using cementless fixation for hip arthroplasty in elderly patients. Histologic analysis, radiographic review, and dual-energy x-ray absorptiometry have shown solid osseointegration for biologic fixation and minimal bone loss. Cementless fixation provides superb functional outcomes with results comparable to those achieved using cemented fixation for hip arthroplasty. Additional advantages of cementless femoral fixation include shorter surgical times and substantial savings in health care costs.

  18. Efficacy and safety of the topical application of tranexamic acid in primary cementless hip arthroplasty: prospective, randomised, double-blind and controlled study.

    PubMed

    Tavares Sánchez-Monge, F J; Aguado Maestro, I; Bañuelos Díaz, A; Martín Ferrero, M Á; García Alonso, M F

    To evaluate the efficacy of topical tranexamic acid topical in cementless total hip arthroplasty from the point of view of bleeding, transfusion requirements and length of stay, and describe the complications of use compared to a control group. A prospective, randomised, double-blinded and controlled study including all patients undergoing cementless total hip arthroplasty in our centre between June 2014 and July 2015. Blood loss was estimated using the formula described by Nadler and Good. The final analysis included 119 patients. The decrease in haemoglobin after surgery was lower in the tranexamic acid group (3.28±1.13g/dL) than in the controls (4.03±1.27g/dL, P=.001) and estimated blood loss (1,216.75±410.46mL vs. 1,542.12±498.97mL, P<.001), the percentage of transfused patients (35.9% vs. 19.3%, P<.05) and the number of transfused red blood cell units per patient (0.37±0.77 vs. 0.98±1.77; P<.05). There were no differences between groups in the occurrence of complications or length of stay. The use of topical tranexamic acid in cementless total hip arthroplasty results in a decrease in bleeding and transfusion requirements without increasing the incidence of complications. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. The results of a proximally-coated cementless femoral component in total hip replacement: a five- to 12-year follow-up.

    PubMed

    Kim, Y-H

    2008-03-01

    This study reviewed the results of a cementless anatomical femoral component to give immediate post-operative stability, and with a narrow distal section in order not to contact the femoral cortex in the diaphysis, ensuring exclusively metaphyseal loading. A total of 471 patients (601 hips) who had a total hip replacement between March 1995 and February 2002 were included in the study. There were 297 men and 174 women. The mean age at the time of operation was 52.7 years (28 to 63). Clinical and radiological evaluation were performed at each follow-up. Bone densitometry was carried out on all patients two weeks after operation and at the final follow-up examination. The mean follow-up was 8.8 years (5 to 12). The mean pre-operative Harris hip score was 41 points (16 to 54), which improved to a mean of 96 (68 to 100) at the final follow-up. No patient complained of thigh pain at any stage. No acetabular or femoral osteolysis was observed and no hip required revision for aseptic loosening of either component. Deep infection occurred in two hips (0.3%) which required revision. One hip (0.2%) required revision of the acetabular component for recurrent dislocation. Bone mineral densitometry revealed a minimal bone loss in the proximal femur. This cementless anatomical femoral component with metaphyseal loading but without distal fixation produced satisfactory fixation and encourages proximal femoral loading.

  20. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis

    PubMed Central

    Choi, Yoowang; Kim, Jun-Shik

    2009-01-01

    Despite improvements in the quality of alumina ceramics, osteolysis has been reported anecdotally after total hip arthroplasty (THA) with use of a contemporary alumina-on-alumina ceramic bearing. The purpose of this study was to evaluate the clinical and radiographic outcomes of THA using alumina-on-alumina ceramic bearing and to determine osteolysis using radiographs and computed tomographic (CT) scans in young patients. Consecutive primary cementless THA using alumina-on-alumina ceramic bearing were performed in 64 patients (93 hips) who were younger than 45 years of age with femoral-head osteonecrosis. There were 55 men (84 hips) and nine women (nine hips). Average age was 38.2 (range 24–45) years. Average follow-up was 11.1 (range 10–13) years. Preoperative Harris Hip Score was 52.9 (range 22–58) points, which improved to 96 (range 85−100) points at the final follow-up examination. Two of 93 hips (2%) had clicking or squeaking sound. No hip had revision or aseptic loosening. Radiographs and CT scans demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up. Contemporary cementless acetabular and femoral components with alumina-on-alumina ceramic bearing couples function well with no osteolysis at a ten year minimum and average of 11.1-year follow-up in this series of young patients with femoral-head osteonecrosis. PMID:19784647

  1. Complications of porous-coated press-fit cementless total hip replacement in dogs.

    PubMed

    Kidd, Scott W; Preston, Christopher A; Moore, George E

    2016-09-20

    To report postoperative complications using a commercially available porous-coated press-fit cementless total hip replacement (THR) system in dogs. Medical records were reviewed for client-owned dogs with hip pathologies requiring THR. A minimum of six-week postoperative orthopaedic examination and orthogonal pelvic radiographs were used to assess outcome and complications in the perioperative period. Referring veterinarian medical records, phone interviews with clients, or both were used to assess long-term functional outcome and complications. Bilateral THR was performed in 36 dogs, and unilateral in 147 dogs, making a total of 219 THR procedures in 183 dogs. A total complication rate of 31.1% (68/219) was observed. A catastrophic complication was observed in 8.2% (n = 18), a major complication in 9.6% (n = 21), and a minor complication in 13.2% (n = 29) of procedures. The most common complications were intra-operative femoral fissure (n = 46), diaphyseal femoral fracture (n = 15), and coxofemoral luxation (n = 9). Full return to function was achieved in 88.1% of procedures with a median follow-up period of 42 months. Porous-coated press-fit cementless collarless total hip replacements have a high complication rate. The majority of complications occur intra-operatively or perioperatively, with few complications occurring beyond 12 weeks postoperatively. Both fissure fractures and diaphyseal femoral fractures carry a favourable prognosis with immediate cerclage wiring and plate fixation, respectively.

  2. Bilaterally Primary Cementless Total Hip Arthroplasty for Severe Hip Ankylosis with Ankylosing Spondylitis.

    PubMed

    Feng, Dong-Xu; Zhang, Kun; Zhang, Yu-Min; Nian, Yue-Wen; Zhang, Jun; Kang, Xiao-Min; Wu, Shu-Fang; Zhu, Yang-Jun

    2016-08-01

    Total hip arthroplasty is a reliable therapeutic intervention in patients with ankylosing spondylitis, in whom the aims of surgery are to reduce pain, restore hip function and improve quality of life. The current study is a retrospective analysis of the clinical and radiographic findings in a consecutive series of patients with hip ankylosis associated with severe ankylosing spondylitis who underwent bilateral primary total hip arthroplasty using non-cemented components. From June 2008 to May 2012, total hip arthroplasty was performed on 34 hips in 17 patients with bilateral ankylosis caused by ankylosing spondylitis. The study patients included 13 men and 4 women with a mean age of 24.2 years. The mean duration of disease was 8.3 years and the average duration of hip involvement was 7.6 years. All patients had severe hip pain and dysfunction with bilateral bony ankylosis and no range of motion preoperatively and all underwent bilateral cementless total hip arthroplasty performed by a single surgeon. Joint pain, range of motion (ROM), and Harris hip scores were assessed to evaluate the postoperative results. At a mean follow-up of 31.7 months, all patients had experienced significant clinical improvement in function, ROM, posture and ambulation. At the final follow-up, the mean postoperative flexion ROM was 134.4° compared with 0° preoperatively. Similar improvements were seen in hip abduction, adduction, internal rotation and external rotation. Postoperatively, 23 hips were completely pain-free, six had only occasional discomfort, three mild to moderate pain and two severe pain. The average Harris Hip Score improved from 23.7 preoperatively to 65.8 postoperatively. No stems had loosened at the final follow-up in any patient, nor had any revision surgery been required. Bilateral severe hip ankylosis in patients with ankylosing spondylitis can be treated with cementless bilateral synchronous total hip arthroplasty, which can greatly improve hip joint function and relieve pain without significant complications. Provided the overall physical condition of a patient and their economic situation make surgery a feasible option and the surgeon is experienced, this treatment is a worthwhile surgical intervention for bilateral hip bony ankylosis. However, the technically demanding nature of the procedure and potential pre- and post-operative problems should not be underestimated. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  3. Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

    PubMed

    Lee, Paul Yuh Feng; Rachala, Madhu; Teoh, Kar Ho; Woodnutt, David John

    2016-09-01

    Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries. We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis. The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening. Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. Therapeutic III; therapeutic study.

  4. Primary cementless total hip arthroplasty with second-generation metal-on-metal bearings: a concise follow-up, at a minimum of seventeen years, of a previous report.

    PubMed

    Lass, R; Grübl, A; Kolb, A; Domayer, S; Csuk, C; Kubista, B; Giurea, A; Windhager, R

    2014-03-05

    Second-generation, metal-on-metal bearings were introduced in 1988, to reduce wear and avoid polyethylene particle-induced osteolysis from total hip arthroplasty. In 2007, we reported the long-term results of ninety-eight patients (105 hips) who underwent primary cementless total hip arthroplasty involving the use of a prosthesis with a high-carbide-concentration, metal-on-metal articulating surface between November 1992 and May 1994. The present study gives an update on this patient cohort. At a minimum of seventeen years postoperatively, forty-nine patients (fifty-two hips) were available for follow-up examination. We retrospectively evaluated clinical and radiographic results as well as serum metal concentration. The mean patient age at the time of the index arthroplasty was fifty-six years. Three cups (6% of the hips) and one stem (2% of the hips) were revised because of aseptic loosening of the implants combined with focal osteolysis. At the time of the latest follow-up evaluation, the mean Harris hip score was 88.8 points, and the mean University of California Los Angeles (UCLA) activity score was 6.7 points. The cumulative rate of implant survival, with aseptic failure as the end point, was 93.0% at 18.8 years. The median serum cobalt concentration in patients whose hip implant was the only source of cobalt was 0.70 μg/L (range, 0.4 to 5.1 μg/L), showing no increase in the value as noted at a minimum of ten years of follow-up. The clinical and radiographic results of our study, which, to our knowledge, represent the longest duration of follow-up for a series of cementless total hip arthroplasties with use of a 28-mm metal-on-metal bearing, continue to be comparable with the results observed for other hard-on-hard bearings.

  5. The tridimensional geometry of the proximal femur should determine the design of cementless femoral stem in total hip arthroplasty.

    PubMed

    Wegrzyn, Julien; Roux, Jean-Paul; Loriau, Charlotte; Bonin, Nicolas; Pibarot, Vincent

    2018-02-22

    Using a cementless femoral stem in total hip arthroplasty (THA), optimal filling of the proximal femoral metaphyseal volume (PFMV) and restoration of the extramedullary proximal femoral (PF) parameters (i.e., femoral offset (FO), neck length (FNL), and head height (FHH)) constitute key goals for optimal hip biomechanics, functional outcome, and THA survivorship. However, almost 30% of mismatch between the PF anatomy and implant geometry of the most widely implanted non-modular cementless femoral stem has been demonstrated in a computed tomography scan (CT scan) study. Therefore, this anatomic study aimed to evaluate the relationship between the intra- and extramedullary PF parameters using tridimensional CT scan reconstructions. One hundred fifty-one CT scans of adult healthy hips were obtained from 151 male Caucasian patients (mean age = 66 ± 11 years) undergoing lower limb CT scan arteriography. Tridimensional PF reconstructions and parameter measurements were performed using a corrected PF coronal plane-defined by the femoral neck and diaphyseal canal longitudinal axes-to avoid influence of PF helitorsion and femoral neck version on extramedullary PF parameters. Independently of the femoral neck-shaft angle, the PFMV was significantly and positively correlated with the FO, FNL, and FHH (r = 0.407 to 0.420; p < 0.0001). This study emphasized that the tridimensional PF geometry measurement in the corrected coronal plane of the femoral neck can be useful to determine and optimize the design of a non-modular cementless femoral stem. Particularly, continuous homothetic size progression of the intra- and extramedullary PF parameters should be achieved to assure stem fixation and restore anatomic hip biomechanics.

  6. Better early functional outcome after short stem total hip arthroplasty? A prospective blinded randomised controlled multicentre trial comparing the Collum Femoris Preserving stem with a Zweymuller straight cementless stem total hip replacement for the treatment of primary osteoarthritis of the hip

    PubMed Central

    van Oldenrijk, Jakob; Scholtes, Vanessa A B; van Beers, Loes W A H; Geerdink, Carel H; Niers, Bob B A M; Runne, Wouter; Bhandari, Mohit; Poolman, Rudolf W

    2017-01-01

    Objectives Primary aim was to compare the functional results at 3 months and 2 years between short and conventional cementless stem total hip arthroplasty (THA). Secondary aim was to determine the feasibility of a double-blind implant-related trial. Design A prospective blinded randomised controlled multicentre trial in patients with osteoarthritis of the hip. All patients, research assistants, clinical assessors, investigators and data analysts were blinded to the type of prosthesis. Population: 150 patients between 18 and 70 years with osteoarthritis of the hip, 75 in the short stem and 75 in the conventional stem group. Mean age: 60 years (SD 7). Interventions: the Collum Femoris Preserving short stem versus the Zweymuller Alloclassic conventional stem. Main outcome measures The Dutch version of the Hip Disability and Osteoarthritis Outcome Score (HOOS). Secondary outcomes measures: Harris Hip Score, the Physical Component Scale of the SF12, the Timed Up and Go test, Pain and the EQ-5D. Feasibility outcomes: continued blinding, protocol adherence and follow-up success rate. Results No significant difference between the two groups. Mean HOOS total score in the short stem group increased 32.7 points from 36.6 (95% CI 32.9 to 40.2) preoperatively to 69.3 (95% CI 66.4 to 72.1) at 3 months follow-up. Mean HOOS total score in the conventional straight stem group increased 36.3 points from 37.1 (95% CI 33.9 to 40.3) preoperatively to 73.4 (95% CI 70.3 to 76.4) at 3 months follow-up. 91.2% of patients remained blinded at 2 years follow-up. Both protocol adherence and follow-up success rate were 98%. Conclusions Functional result at 3 months and 2 years after short stem THA is not superior to conventional cementless THA. There were more perioperative and postoperative complications in the short stem group. Direct comparison of two hip implants in a double-blinded randomised controlled trial is feasible. Trial registration number NTR1560. PMID:29042371

  7. Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.

    PubMed

    Cooke, Christopher C; Hozack, William; Lavernia, Carlos; Sharkey, Peter; Shastri, Shani; Rothman, Richard H

    2003-10-01

    Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Eight patients (13.8%) required reoperation for failure of the constrained implant. Type I failure (bone-prosthesis interface) occurred in 3 cases. Two cementless shells became loose, and in 1 patient, the constrained liner was cemented into an acetabular cage, which then failed by pivoting laterally about the superior fixation screws. Type II failure (liner locking mechanism) occurred in 2 cases. Type III failure (femoral head locking mechanism) occurred in 3 patients. Seven of the 8 failures occurred in patients with recurrent instability. Constrained liners are an effective method for treatment during revision total hip arthroplasty but should be used in select cases only.

  8. [Stress analysis of femoral stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer].

    PubMed

    Oomori, H; Imura, S; Gesso, H

    1992-04-01

    To develop stem design achieving primary fixation of stems and effective load transfer to the femur, we studied stress analysis of stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer in stem-bone interface. The results of analyses of stem-bone interface stresses and von Mises stresses at the cortical bones indicated that ideal stem design features would be as follows: 1) Sufficient length, with the distal end extending beyond the isthmus region. 2) Maximum possible width, to contact the cortical bones in the isthmus region. 3) No collars but a lateral shoulder at the proximal portion. 4) A distal tip, to contact the cortical bones at the distal portion.

  9. Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems.

    PubMed

    Grant, Tanner W; Lovro, Luke R; Licini, David J; Warth, Lucian C; Ziemba-Davis, Mary; Meneghini, Robert M

    2017-03-01

    Femoral component stability and resistance to subsidence is critical for osseointegration and clinical success in cementless total hip arthroplasty. The purpose of this study was to radiographically evaluate the anatomic fit and subsidence of 2 different proximally tapered, porous-coated modern cementless femoral component designs. A retrospective cohort study of 126 consecutive cementless total hip arthroplasties was performed. Traditional fit-and-fill stems were implanted in the first 61 hips with the remaining 65 receiving morphometric tapered wedge stems. Preoperative bone morphology was radiographically assessed by the canal flare index. Canal fill in the coronal plane, subsidence, and the sagittal alignment of stems was measured digitally on immediate and 1-month postoperative radiographs. Demographics and canal flare indices were similar between groups. The percentage of femoral canal fill was greater in the tapered wedge compared to the fit-and-fill stem (P = .001). There was significantly less subsidence in the tapered wedge design (0.3 mm) compared to the fit-and-fill design (1.1 mm) (P = .001). Subsidence significantly increased as body mass index (BMI) increased in the fit-and-fill stems, a finding not observed in the tapered wedge design (P = .013). An anatomically designed morphometric tapered wedge femoral stem demonstrated greater axial stability and decreased subsidence with increasing BMI than a traditional fit-and-fill stem. The resistance to subsidence, irrespective of BMI, is likely due to the inherent axial stability of a tapered wedge design and may be the optimal stem design for obese patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Impact of a learning curve on the survivorship of 4802 cementless total hip arthroplasties.

    PubMed

    Magill, P; Blaney, J; Hill, J C; Bonnin, M P; Beverland, D E

    2016-12-01

    Our aim was to report survivorship data and lessons learned with the Corail/Pinnacle cementless total hip arthroplasty (THA) system. Between August 2005 and March 2015, a total of 4802 primary cementless Corail/Pinnacle THAs were performed in 4309 patients. In March 2016, we reviewed these hips from a prospectively maintained database. A total of 80 hips (1.67%) have been revised which is equivalent to a cumulative risk of revision of 2.5% at ten years. The rate of revision was not significantly higher in patients aged ≥ 70 years (p = 0.93). The leading indications for revision were instability (n = 22, 0.46%), infection (n = 20, 0.42%), aseptic femoral loosening (n = 15, 0.31%) and femoral fracture (n = 6, 0.12%). There were changes in the surgical technique with respect to the Corail femoral component during the ten-year period involving a change to collared components and a trend towards larger size. These resulted in a decrease in the rate of iatrogenic femoral fracture and a decrease in the rate of aseptic loosening. The rate of revision in this series is comparable with the best performing THAs in registry data. Most revisions were not directly related to the implants. Despite extensive previous experience with cemented femoral components, the senior author noted a learning curve requiring increased focus on primary stability. The number of revisions related to the femoral component is reducing. Any new technology has a learning curve that may be independent of surgical experience. Cite this article: Bone Joint J 2016;98-B:1589-96. ©2016 The British Editorial Society of Bone & Joint Surgery.

  11. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years.

    PubMed

    Berend, Keith R; Lombardi, Adolph V; Mallory, Thomas H; Chonko, Douglas J; Dodds, Kathleen L; Adams, Joanne B

    2004-10-01

    Initial stability is critical for fixation and survival of cementless total hip arthroplasty. Occasionally, a split of the calcar occurs intraoperatively. A review of 1,320 primary total hip arthroplasties with 2-year follow-up, performed between August 1985 and February 2001 using the Mallory-Head Porous tapered femoral component, revealed 58 hips in 55 patients with an intraoperative calcar fracture managed with single or multiple cerclage wires or cables and immediate full weight bearing. At 7.5 years average follow-up (range, 2-16 years), there were no revisions of the femoral component, radiographic failures, or patients with severe thigh pain, for a stem survival rate of 100%. Average Harris hip score improvement was 33.8 points. Fracture of the proximal femur occurs in approximately 4% of primary THAs using the Mallory-Head Porous femoral component. When managed intraoperatively with cerclage wire or cable, the mid- to long-term results appear unaffected with 100% femoral component survival at up to 16 years.

  12. Bilateral total hip arthroplasty in Morquio-Brailsford's syndrome: a report of two cases.

    PubMed

    Tassinari, Enrico; Boriani, Luca; Traina, Francesco; Dallari, Dante; Toni, Aldo; Giunti, Armando

    2008-09-01

    We report two cases of bilateral cementless total hip arthroplasty in two young women affected by Morquio-Brailsford syndrome. Morquio-Brailsford disease belongs to the mucopolysaccharidoses; it shows growth retardation with disproportional dwarfism. Usually patients are affected by a severe joint degeneration from their 2nd or 3rd decade. Young age, severe dysplasia, and joint size are the main technical problems for a total hip replacement. Accurate radiographic and CT planning allows the use of standard prostheses instead of custom-made ones.

  13. [The incidence of osteopenia and osteoporosis in patients with cementless total hip arthroplasty].

    PubMed

    Lacko, M; Schreierová, D; Čellár, R; Vaško, G

    2015-01-01

    The aim of the study was to evaluate the incidence of osteopenia and osteoporosis in the patients elected to cementless total hip replacement. The group evaluated comprised 100 patients with primary or secondary forms of coxarthrosis who underwent cementless total hip arthroplasty (THA). The results of densitometric examination of the lumbar spine and proximal femur were analysed. Based on the lowest T-score value, the patients were divided into three groups, i.e., fist, normal bone density; second, osteopenia; third, osteoporosis. Clinical examination included patient medical history, Harris hip scores and visual analogue scale assessment for pain intensity; the Kellgren-Lawrence classification was used to measure the grade of hip osteoarthritis; blood tests were made to assess the levels of total calcium, ionised calcium, phosphorus, vitamin D and the markers of bone resorption and formation. Osteoporosis was found in 32 and osteopenia in 21 patients; 47 patients had normal bone density. Osteoporosis was detected in the lumbar spine of 21 patients, in the proximal femur of nine patients and at both sites in two patients. In 13 patients this diagnosis was made for the fist time. The patients with osteoporosis had a significantly lower body mass index. There were no differences in the other characteristics, i.e., age, functional, radiological and laboratory findings, among the groups; all three showed the mean vitamin D concentration below the lowest level of its physiological range. Insufficient vitamin D levels were found in 54 women and 18 men. Of all patients, only 13 women and four men took vitamin D supplements. DISCUSSION Osteoarthritis and osteoporosis are the most frequent complex musculoskeletal diseases. Several studies have suggested that these disorders are mutually exclusive. This assumption has been based on the absence of radiographic evidence of osteoarthritis seen in many elderly patients with femoral neck fractures. Our relatively frequent findings of osteopenia and osteoporosis in this study show that patients with osteoarthritis may not be protected from the development of generalised osteoporosis. Our results are compared with the relevant literature data and potential effects of osteoporosis and vitamin D deficiency on total hip arthroplasty are discussed. Hip osteoarthritis does not reduce the risk of generalised osteoporosis. We found a relative high incidence of osteopenia and osteoporosis as well as vitamin D deficiency in patient with advanced form of hip osteoarthritis.

  14. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study.

    PubMed

    Goossens, Quentin; Leuridan, Steven; Henyš, Petr; Roosen, Jorg; Pastrav, Leonard; Mulier, Michiel; Desmet, Wim; Denis, Kathleen; Vander Sloten, Jos

    2017-11-01

    In cementless total hip arthroplasty (THA), the initial stability is obtained by press-fitting the implant in the bone to allow osseointegration for a long term secondary stability. However, finding the insertion endpoint that corresponds to a proper initial stability is currently based on the tactile and auditory experiences of the orthopedic surgeon, which can be challenging. This study presents a novel real-time method based on acoustic signals to monitor the acetabular implant fixation in cementless total hip arthroplasty. Twelve acoustic in vitro experiments were performed on three types of bone models; a simple bone block model, an artificial pelvic model and a cadaveric model. A custom made beam was screwed onto the implant which functioned as a sound enhancer and insertor. At each insertion step an acoustic measurement was performed. A significant acoustic resonance frequency shift was observed during the insertion process for the different bone models; 250 Hz (35%, second bending mode) to 180 Hz (13%, fourth bending mode) for the artificial bone block models and 120 Hz (11%, eighth bending mode) for the artificial pelvis model. No significant frequency shift was observed during the cadaveric experiment due to a lack of implant fixation in this model. This novel diagnostic method shows the potential of using acoustic signals to monitor the implant seating during insertion. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Fixation method does not affect restoration of rotation center in hip replacements: A single-site retrospective study

    PubMed Central

    2012-01-01

    Background Aseptic loosening is one of the greatest problems in hip replacement surgery. The rotation center of the hip is believed to influence the longevity of fixation. The aim of this study was to compare the influence of cemented and cementless cup fixation techniques on the position of the center of rotation because cemented cup fixation requires the removal of more bone for solid fixation than the cementless technique. Methods We retrospectively compared pre- and post-operative positions of the hip rotation center in 25 and 68 patients who underwent artificial hip replacements in our department in 2007 using cemented or cementless cup fixation, respectively, with digital radiographic image analysis. Results The mean horizontal and vertical distances between the rotation center and the acetabular teardrop were compared in radiographic images taken pre- and post-operatively. The mean horizontal difference was −2.63 mm (range: -11.00 mm to 10.46 mm, standard deviation 4.23 mm) for patients who underwent cementless fixation, and −2.84 mm (range: -10.87 to 5.30 mm, standard deviation 4.59 mm) for patients who underwent cemented fixation. The mean vertical difference was 0.60 mm (range: -20.15 mm to 10.00 mm, standard deviation 3.93 mm) and 0.41 mm (range: -9.26 mm to 6.54 mm, standard deviation 3.58 mm) for the cementless and cemented fixation groups, respectively. The two fixation techniques had no significant difference on the position of the hip rotation center in the 93 patients in this study. Conclusions The hip rotation center was similarly restored using either the cemented or cementless fixation techniques in this patient cohort, indicating that the fixation technique itself does not interfere with the position of the center of rotation. To completely answer this question further studies with more patients are needed. PMID:22686355

  16. Comparison of the risk of revision in cementless total hip arthroplasty with ceramic-on-ceramic and metal-on-polyethylene bearings

    PubMed Central

    Varnum, Claus; Pedersen, Alma B; Kjærsgaard-Andersen, Per; Overgaard, Søren

    2015-01-01

    Background and purpose Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA. Patients and methods In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk. Results 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture. Interpretation When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years. PMID:25637339

  17. Canine total hip replacement using a cementless threaded cup and stem: a review of 55 cases.

    PubMed

    Denny, H R; Linnell, M; Maddox, T W; Comerford, E J

    2018-06-01

    To determine the long-term results and complications associated with the Helica ® cementless hip endoprosthesis system. Retrospective study of 55 consecutive Helica total hip replacements performed between January 2010 and February 2015. A total of 55 total hip replacements were performed in 50 dogs; 45 dogs had unilateral hip replacements, and five had staged bilateral replacements. A total of 23 first-generation short femoral stems were implanted in 22 dogs, of which nine cases (39%) experienced complications and 19 (86%) recovered satisfactorily when revisions were included; 31 second-generation femoral stems were implanted in 28 dogs, of which 10 cases (32%) experienced complications, and 26 (93%) made satisfactory recoveries, including revisions. In 36 dogs for which data were available, postoperative Liverpool Osteoarthritis in Dogs scores were significantly reduced compared to preoperative scores. Complications occurred in a total of 19 cases (34·5%; 95% confidence interval: 22 to 47·1%); the most common was aseptic loosening of the femoral stem [11 cases (20%; 95% confidence interval: 9·4 to 30·6%)]. Following multivariable analysis, no risk factors were identified for overall complications, but there was a significant association of implant type (first-generation short stem) with loosening (odds ratio 4·9, 95% confidence interval: 1·1 to 22·1, P=0·034). This study found the Helica hip endoprosthesis system to be effective in the management of hip dysplasia and osteoarthritis in dogs. Aseptic loosening of the femoral stem remains the most common complication but appears to have been significantly reduced with the introduction of the second-generation stem. © 2018 British Small Animal Veterinary Association.

  18. Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty

    PubMed Central

    Mishima, Hajime; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips) were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months). Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips) of those occurring within 3 months after surgery. First- (n = 12 hips), second- (n = 32), and third- (n = 1) degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100%) and posteromedial distal portions (85%). Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree. PMID:26881087

  19. Have cementless and resurfacing components improved the medium-term results of hip replacement for patients under 60 years of age?

    PubMed Central

    Mason, James; Baker, Paul; Gregg, Paul J; Porter, Martyn; Deehan, David J; Reed, Mike R

    2015-01-01

    Background and purpose The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. Methods We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or resurfacing prosthesis (11,622 women and 13,087 men). The reference implant comprised a cemented stem with a conventional polyethylene cemented cup and a standard-sized head (28- or 32-mm). Differences in implant survival were assessed using competing-risks models, adjusted for known prognostic influences. Analysis of covariance was used to assess improvement in PROMs (Oxford hip score (OHS) and EQ5D index) in 2014 linked procedures. Results In males, PROMs and implant survival were similar across all types of implants. In females, revision was statistically significantly higher in hard-bearing and/or small-stem cementless implants (hazard ratio (HR) = 4) and resurfacings (small head sizes (< 48 mm): HR = 6; large head sizes (≥ 48 mm): HR = 5) when compared to the reference cemented implant. In component combinations with equivalent survival, women reported significantly greater improvements in OHS with hybrid implants (22, p = 0.006) and cementless implants (21, p = 0.03) (reference, 18), but similar EQ5D index. For men and women, National Health Service (NHS) costs were lowest with the reference implant and highest with a hard-bearing cementless replacement. Interpretation In young women, hybrids offer a balance of good early functional improvement and low revision risk. Fully cementless and resurfacing components are more costly and do not provide any additional benefit for younger patients. PMID:25285617

  20. Bipolar Hemarthroplasty Using Cementless Conical Stem for Treatment of Dorr Type B and C Femoral Neck Fracture.

    PubMed

    Kang, Jeong Hoon; Lee, Sang Hong; Jung, Sung

    2015-12-01

    The current study aims to evaluate the clinical and the radiological outcome of bipolar hemiarthroplasty using cementless cone stem to treat osteoporotic femoral neck fracture and compare the results according to the proximal femur geometry. Seventy-five hips (75 patients) that underwent bipolar hemiarthroplasty with cementless cone stem between September 2006 and December 2011 were analyzed. The minimum follow-up period was 3 years. Thirty-three hips were classified as type B and 41 as type C. The clinical outcome was assessed using Harris hip score and the walking ability score. Radiographic evaluation was performed to evaluate the stability of the prosthesis. At the most recent follow up, the mean Harris hip score was 86 (range, 70-92) and 65% recovered to preoperative ambulatory status. In the radiographic exam, stable stem fixation was achieved in all cases. For the complications, eight hips developed deep vein thrombosis while three hips showed heterotopic ossification. Dislocation and delayed deep infection occurred in one hip resepectively. There were no significance differences in Harris hip score and walking ability score when the type B group was compare with the type C. Bipolar hemiarthroplasty with cementless cone stem showed an excellent early outcome both clinically and radiographically regardless of the shape of the proximal femur. We believe this prosthesis can provide early stability to the Dorr type B and C femur and is an effective treatment for treating osteoporotic femoral neck fracture.

  1. Total Hip Arthroplasty Using a Polished Tapered Cemented Stem in Hereditary Multiple Exostosis

    PubMed Central

    Kanda, Akio; Kaneko, Kazuo; Obayashi, Osamu; Mogami, Atsuhiko

    2016-01-01

    A 61-year-old Japanese man underwent right total hip arthroplasty for hereditary multiple exostosis. At first presentation, he had suffered from coxalgia for a long time. On radiographic images, there was a gigantic femoral head, increased shaft angle, and large diameter of the femoral neck. He had also developed coxarthrosis and severe pain of the hip joint. The transformation of the proximal femur bone causes difficulty in setting a cementless total hip prosthesis. Therefore, total hip arthroplasty using a cemented polished tapered stem was performed via a direct lateral approach. Using a cemented polished tapered stem allowed us to deal with the femoral bone transformation and bone substance defectiveness due to exostosis and also minimized the invasiveness of the operation. PMID:27127668

  2. Two-Stage Progressive Femoral Lowering Followed by Cementless Total Hip Arthroplasty for Treating Crowe IV-Hartofilakidis Type 3 Developmental Dysplasia of the Hip.

    PubMed

    Binazzi, Roberto

    2015-05-01

    High developmental dysplasia of the hip is commonly treated with total hip arthroplasty and shortening osteotomy. We present a two stage technique, consisting of progressive femoral lowering followed by total hip arthroplasty. The clinico-radiographic results of eleven patients (twelve hips) who were operated on with the two-stage technique were evaluated at a mean follow-up of 11 ± 5 years. At the final follow-up, ten patients (eleven hips) had a mean Harris hip score of 85 ± 5 points with no implant loosening. One patient (one hip) was revised at 5 years due to infection. No neurovascular complications were observed in any patients. With this technique, we could place the cup in the anatomical position and obtain complete limb symmetry with excellent clinical results at long-term. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Cementless Hydroxyapatite Coated Hip Prostheses

    PubMed Central

    Herrera, Antonio; Mateo, Jesús; Gil-Albarova, Jorge; Lobo-Escolar, Antonio; Ibarz, Elena; Gabarre, Sergio; Más, Yolanda

    2015-01-01

    More than twenty years ago, hydroxyapatite (HA), calcium phosphate ceramics, was introduced as a coating for cementless hip prostheses. The choice of this ceramic is due to its composition being similar to organic apatite bone crystals. This ceramic is biocompatible, bioactive, and osteoconductive. These qualities facilitate the primary stability and osseointegration of implants. Our surgical experience includes the implantation of more than 4,000 cementless hydroxyapatite coated hip prostheses since 1990. The models implanted are coated with HA in the acetabulum and in the metaphyseal area of the stem. The results corresponding to survival and stability of implants were very satisfactory in the long-term. From our experience, HA-coated hip implants are a reliable alternative which can achieve long term survival, provided that certain requirements are met: good design selection, sound choice of bearing surfaces based on patient life expectancy, meticulous surgical technique, and indications based on adequate bone quality. PMID:25802848

  4. Operative tactics and results of treatment of patients with coxarthrosis secondary to congenital high luxation of hip joints.

    PubMed

    Król, Roman; Rojewski, Marek; Kamiński, Adam; Popławski, Tomasz

    2007-01-01

    Treatment of the sequelae of congenital high luxation of the hip joint is a major challenge in prosthetic surgery, demanding from the operator thorough familiarity with the problem and experience in hop reconstructive surgery. The results of 4 years observation, of the treatment of 14 woman in the average age of 38 years old with 18 hip joints with congenital high luxation are presented. In all cases cementless total hip arthroplasty was made. Acetabular component of the prosthesis was implanted correctly and stable in its physiological placement. Femur was shortened average 4 cm and stabilized by cementless press-fit stem of prosthesis. The place of femur osteotomy was covered with autogenic spongy bone from resected caput of femur. The union was achieved after average 10 weeks. In clinical assessment there were obtained 10 very good, 5 good and 3 satisfactory clinical results. There were no superficial or deep infections, no neurological disorders and no loosening of components of implanted prostheses observed. 1. Careful planning and carrying out the operative procedures allow to insert the acetabular component of the prosthesis in its physiological place and achieve good results. 2. Shortening of femur and repositioning of components of prosthesis in 90 degrees knee flexion and also position on broken bed after operative procedure allowed to avoid neurological disorders. 3. Cementless and hydroxyapatite-covered femoral component of the prosthesis correctly stabilize place of femur osteotomy.

  5. Correlation between thigh pain and radiological findings with a proximally porous-coated stem.

    PubMed

    Kinov, Plamen; Radl, Roman; Zacherl, Maximilian; Leithner, Andreas; Windhager, Reinhard

    2007-10-01

    Thigh pain has been consistently reported with cementless hip arthroplasty. The correlation between thigh pain and radiological findings and the clinical significance of thigh pain have not been studied in any detail. We carried out a retrospective study to analyse the performance of a proximally porous-coated cementless femoral component. Ninety-eight total hip arthroplasties were followed up clinically and radiologically for an average of 33 months (range: 12 to 64) after operation. The clinical results were good or excellent in 85 cases (87%). Thirteen patients (13%) reported thigh pain at latest follow-up. Subsidence of the stem was recorded in 10 cases, cortical thickening occurred in 14 hips (14%), and 17 hips (17%) presented proximal osteopenia. Proximally, radiolucent lines were observed in 11 cases. Thigh pain correlated with radiolucent lines, femoral thickening, fibrous fixation and stem migration. Bone remodelling was noted to continue even five years after implantation. Our observations demonstrated bone ingrowth in the majority of the cases and a low incidence of thigh pain. The correlation between radiological changes and thigh pain suggests implant micromotion and migration in some hips. Patients with thigh pain, changes in the proximal femur and progressive subsidence need further clinical and radiological follow-up.

  6. [Hip resurfacing arthroplasty].

    PubMed

    Witzleb, W-C; Knecht, A; Beichler, T; Köhler, T; Günther, K-P

    2004-11-01

    In comparison to stemmed total hip replacements, hip resurfacing offers advantages especially in joint stability and amount of femoral bone resection. After the poor results achieved with this concept that were mainly caused by failure of the materials used, reintroduction of the metal-on-metal bearing initiated a renaissance. This bearing, the cementless cup, and the improved surgical technique led to better short- to medium-term results. Revision and complication rates are now comparable to conventional total hip replacements. The functional capacity of the method is higher. Because long-term results are not available, however, questions remain, for instance, the consequences of the higher metal ion serum concentrations or the impossibility of changing the inlay when femoral revision becomes necessary.

  7. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  8. Mesh morphing for finite element analysis of implant positioning in cementless total hip replacements.

    PubMed

    Bah, Mamadou T; Nair, Prasanth B; Browne, Martin

    2009-12-01

    Finite element (FE) analysis of the effect of implant positioning on the performance of cementless total hip replacements (THRs) requires the generation of multiple meshes to account for positioning variability. This process can be labour intensive and time consuming as CAD operations are needed each time a specific orientation is to be analysed. In the present work, a mesh morphing technique is developed to automate the model generation process. The volume mesh of a baseline femur with the implant in a nominal position is deformed as the prosthesis location is varied. A virtual deformation field, obtained by solving a linear elasticity problem with appropriate boundary conditions, is applied. The effectiveness of the technique is evaluated using two metrics: the percentages of morphed elements exceeding an aspect ratio of 20 and an angle of 165 degrees between the adjacent edges of each tetrahedron. Results show that for 100 different implant positions, the first and second metrics never exceed 3% and 3.5%, respectively. To further validate the proposed technique, FE contact analyses are conducted using three selected morphed models to predict the strain distribution in the bone and the implant micromotion under joint and muscle loading. The entire bone strain distribution is well captured and both percentages of bone volume with strain exceeding 0.7% and bone average strains are accurately computed. The results generated from the morphed mesh models correlate well with those for models generated from scratch, increasing confidence in the methodology. This morphing technique forms an accurate and efficient basis for FE based implant orientation and stability analysis of cementless hip replacements.

  9. Ibandronate and cementless total hip arthroplasty: densitometric measurement of periprosthetic bone mass and new therapeutic approach to the prevention of aseptic loosening

    PubMed Central

    Muratore, Maurizio; Quarta, Eugenio; Quarta, Laura; Calcagnile, Fabio; Grimaldi, Antonella; Orgiani, M. Antonio; Marsilio, Antonio; Rollo, Giuseppe

    2012-01-01

    Summary Studies of the mechanisms of periprosthetic bone loss have led to the development of pharmacologic strategies intended to enhance bone mass recovery after surgery and consequently prevent aseptic loosening and prolong the implant survival. Bisphosphonates, potent anti-resorptive drugs widely used in the treatment of osteoporosis and other disorders of bone metabolism, were shown to be particularly effective in reducing periprosthetic bone resorption in the first year after hip and knee arthroplasty, both cemented and cementless. Based on these results, we investigated the inhibitory effects of ibandronate on periprosthetic bone loss in a 2-year study of postmenopausal women that underwent cementless total hip arthroplasty. In the first 6 months both groups (A, treated with ibandronate 3 mg i.v. within five days after surgery and then with oral ibandronate 150 mg/month, plus calcium and vitamin D supplementation; and B, treated with calcium and vitamin D supplementation only) experienced bone loss, though to a lesser extent in group A. After 12 months, group A showed a remarkable BMD recovery, that was statistically significant versus baseline values (about +1, 74% of global BMD) and most evident in region R1 (+3, 81%) and R2 (+4, 12%); in group B, on the contrary, BMD values were unchanged compared with those at 6 months post-surgery. Quality of life scores also showed a greater improvement in group A, both at 6 and 12 months after surgery, likely because of the pain-reducing effects of ibandronate treatment. PMID:22783337

  10. Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?

    PubMed

    Yoon, Byung-Ho; Lee, Young-Kyun; Yoo, Jeong Joon; Kim, Hee Joong; Koo, Kyung-Hoi

    2014-03-01

    Patients with residual poliomyelitis can have advanced degenerative arthritis of the hip in the paralytic limb or the nonparalytic contralateral limb. Although THA is a treatment option for some of these patients, there are few studies regarding THA in this patient population. We therefore reviewed a group of patients with residual poliomyelitis who underwent cementless THA on either their paralytic limb or nonparalytic limb to assess (1) Harris hip scores, (2) radiographic results, including implant loosening, (3) complications, including dislocation, and (4) limb length discrepancy after recovery from surgery. From January 2000 to December 2009, 10 patients with residual poliomyelitis (10 hips, four paralytic limbs and six nonparalytic contralateral limbs) underwent THA using cementless prostheses. Harris hip scores, complications, and leg length discrepancy were determined by chart review, and confirmed by questionnaire and examination; radiographs were reviewed by two observers for this study. Followup was available for all 10 patients at a minimum of 3 years (median, 7 years; range, 3.4-13 years). Surgery was done at the same side of the paralytic limb in four hips and contralateral to the paralytic limb in six. All patients had pain relief and improvement in function; the Harris hip score improved from mean of 68 preoperatively to 92 at last followup (p = 0.043). However, only three patients had complete pain relief. One hip dislocated, which was treated successfully with closed reduction and a hip spica cast for 2 months. There was no loosening or osteolysis in this series. Leg length discrepancy improved after the index operation, but only in the THAs performed in the paralytic limbs. Cementless THA may be suitable for painful hips in adult patients with residual poliomyelitis. Nonetheless, these patients should be informed of the possibility of mild residual pain and persistent leg length discrepancy, particularly patients whose THA is performed on the limb that was not affected by polio (ie, the nonparalytic contralateral limb). Level IV, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence.

  11. THA Using Metal-on-Metal Articulation in Active Patients Younger Than 50 Years

    PubMed Central

    Bonnomet, François; Clavert, Philippe; Laffargue, Philippe; Migaud, Henri

    2008-01-01

    The main concern of patients with longer life expectancies and of patients who are younger and more active is the longevity of their total hip arthroplasty. We retrospectively reviewed 83 cementless total hip arthroplasties in 73 patients implanted with metal-on-metal articulation. All patients were younger than 50 years old (average age, 41 years) at the time of the index procedure, and 80% of the patients had an activity level graded 4 or 5 when measured with the system of Devane et al. A 28-mm Metasul articulation was used with three different cementless titanium acetabular components. At the most recent followup (average, 7.3 years), the average Merle d’Aubigné-Postel score improved from a preoperative 11.1 points to 17.4 points. We observed no radiographic evidence of component loosening. Ten acetabular components had lucency limited to one zone. The 10-year survivorship with the end point of revision (ie, exchange of at least one prosthetic or bearing component) was 100% (95% confidence interval, 90%–100%). Metasul bearings with cementless acetabular components remain promising in this high-risk younger patient population. However, additional followup strategies are recommended to determine any possible long-term deleterious effects associated with the dissemination of metallic ions. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18196415

  12. Two-Stage Cementless Revision Total Hip Arthroplasty for Infected Primary Hip Arthroplasties.

    PubMed

    Camurcu, Yalkin; Sofu, Hakan; Buyuk, Abdul Fettah; Gursu, Sarper; Kaygusuz, Mehmet Akif; Sahin, Vedat

    2015-09-01

    The main purpose of the present study was to analyze the clinical features, the most common infective agents, and the results of two-stage total hip revision using a teicoplanin-impregnated spacer. Between January 2005 and July 2011, 41 patients were included. At the clinical status analysis, physical examination was performed, Harris hip score was noted, isolated microorganisms were recorded, and the radiographic evaluation was performed. The mean Harris hip score was improved from 38.9 ± 9.6 points to 81.8 ± 5.8 points (P<0.05). Infection was eradicated in 39 hips. Radiographic evidence of stability was noted in 37 acetabular revision components, and all femoral stems. Two-stage revision of the infected primary hip arthroplasty is a time-consuming but a reliable procedure with high rates of success. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Chemical Thromboprophylaxis Is Not Necessary to Reduce Risk of Thromboembolism With Tranexamic Acid After Total Hip Arthroplasty.

    PubMed

    Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik

    2017-02-01

    The major concern with the use of tranexamic acid is that it may promote a hypercoagulable state and increase the risk of deep vein thrombosis (DVT) and pulmonary embolism (PE), particularly when chemical thromboprophylaxis is not used. The objective of this study was to ascertain whether tranexamic acid reduces blood loss and transfusion amounts and increases the prevalence of DVT and PE in the patients undergoing primary cementless total hip arthroplasty (THA) without the use of routine chemical thromboprophylaxis. There were 480 patients (582 hips) in the control group who did not receive tranexamic acid and 487 patients (584 hips) in the study group who received tranexamic acid. Mechanical compression device was applied without any chemical thromboprophylaxis. Transfusion rates and volumes were recorded. DVT was diagnosed using both sonogram and venogram at 7 or 8 days postoperatively. All patients had pre- and postoperative perfusion lung scanning to defect pulmonary embolism (PE). Intraoperative (614 vs 389 mL) and postoperative blood loss (515 vs 329 mL) and transfusion volumes (3 units vs 1.5 units) were significantly lower (P < .001) in the tranexamic acid group. The prevalence of DVT was 15% (87 of 582 hips) in the control group and 18% (105 of 584 hips) in the tranexamic acid group. No fatal PE occurred in either group. The use of tranexamic acid reduces the volume of blood transfusion and does not increase the prevalence of DVT or PE in the patients who did not receive routine chemical thromboprophylaxis after primary cementless THA. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Does cemented or cementless single-stage exchange arthroplasty of chronic periprosthetic hip infections provide similar infection rates to a two-stage? A systematic review.

    PubMed

    George, D A; Logoluso, N; Castellini, G; Gianola, S; Scarponi, S; Haddad, F S; Drago, L; Romano, C L

    2016-10-10

    The best surgical modality for treating chronic periprosthetic hip infections remains controversial, with a lack of randomised controlled studies. The aim of this systematic review is to compare the infection recurrence rate after a single-stage versus a two-stage exchange arthroplasty, and the rate of cemented versus cementless single-stage exchange arthroplasty for chronic periprosthetic hip infections. We searched for eligible studies published up to December 2015. Full text or abstract in English were reviewed. We included studies reporting the infection recurrence rate as the outcome of interest following single- or two-stage exchange arthroplasty, or both, with a minimum follow-up of 12 months. Two reviewers independently abstracted data and appraised quality assessment. After study selection, 90 observational studies were included. The majority of studies were focused on a two-stage hip exchange arthroplasty (65 %), 18 % on a single-stage exchange, and only a 17 % were comparative studies. There was no statistically significant difference between a single-stage versus a two-stage exchange in terms of recurrence of infection in controlled studies (pooled odds ratio of 1.37 [95 % CI = 0.68-2.74, I 2  = 45.5 %]). Similarly, the recurrence infection rate in cementless versus cemented single-stage hip exchanges failed to demonstrate a significant difference, due to the substantial heterogeneity among the studies. Despite the methodological limitations and the heterogeneity between single cohorts studies, if we considered only the available controlled studies no superiority was demonstrated between a single- and two-stage exchange at a minimum of 12 months follow-up. The overalapping of confidence intervals related to single-stage cementless and cemented hip exchanges, showed no superiority of either technique.

  15. The effect of a single infusion of zoledronic acid on early implant migration in total hip arthroplasty. A randomized, double-blind, controlled trial.

    PubMed

    Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard

    2009-02-01

    Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.

  16. Bone turnover and periprosthetic bone loss after cementless total hip arthroplasty can be restored by zoledronic acid: a prospective, randomized, open-label, controlled trial.

    PubMed

    Huang, Tsan-Wen; Wang, Chao-Jan; Shih, Hsin-Nung; Chang, Yuhan; Huang, Kuo-Chin; Peng, Kuo-Ti; Lee, Mel S

    2017-05-22

    Although the loss of bone mineral density (BMD) after total hip arthroplasty (THA) is a known problem, it remains unresolved. This study prospectively examined the effect of zoledronic acid (ZA) on bone turnover and BMD after cementless THA. Between January 2010 and August 2011, 60 patients who underwent cementless THA were randomly assigned to receive either ZA infusion or placebo (0.9% normal saline only) postoperatively. ZA was administered at 2 day and 1 year postoperatively. Periprosthetic BMD in seven Gruen zones was assessed preoperatively and at given time points for 2 years. Serum markers of bone turnover, functional scales, and adverse events were recorded. Each group contained 27 patients for the final analysis. The loss of BMD across all Gruen zones (significantly in zones 1 and 7) up to 2 years postoperatively was noted in the placebo group. BMD was significantly higher in the ZA group than in the placebo group in Gruen zones 1, 2, 6, and 7 at 1 year and in Gruen zones 1, 6, and 7 at 2 years (p < 0.05). Compared with baseline measures of BMD, the ZA group had increased BMD in zones 1, 2, 4, 5, 6, and 7 at 1 year and in zones 1, 4, 6, and 7 at 2 years (p < 0.05). Serum bone-specific alkaline phosphatase and N-telopeptide of procollagen I levels were significantly increased at 6 weeks in the placebo group and decreased after 3 months in the ZA group. A transient decrease in osteocalcin level was found at 6 months in the ZA group. Functional scales and adverse events were not different between the two groups. The loss of periprosthetic BMD, especially in the proximal femur (zones 1 and 7), after cementless THA could be effectively reverted using ZA. In addition, bone turnover markers were suppressed until 2 years postoperatively following ZA administration. Chang Gung Memorial Hospital Protocol Record 98-1150A3, Prevention of Periprosthetic Bone Loss After Total Hip Replacement by Annual Bisphosphonate Therapy, has been reviewed and will be made public on ClinicalTrials.gov. NCT02838121 . Registered on 19 July, 2016.

  17. Independent predictors of failure up to 7.5 years after 35 386 single-brand cementless total hip replacements: a retrospective cohort study using National Joint Registry data.

    PubMed

    Jameson, S S; Baker, P N; Mason, J; Rymaszewska, M; Gregg, P J; Deehan, D J; Reed, M R

    2013-06-01

    The popularity of cementless total hip replacement (THR) has surpassed cemented THR in England and Wales. This retrospective cohort study records survival time to revision following primary cementless THR with the most common combination (accounting for almost a third of all cementless THRs), and explores risk factors independently associated with failure, using data from the National Joint Registry for England and Wales. Patients with osteoarthritis who had a DePuy Corail/Pinnacle THR implanted between the establishment of the registry in 2003 and 31 December 2010 were included within analyses. There were 35 386 procedures. Cox proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. The overall rate of revision at five years was 2.4% (99% confidence interval 2.02 to 2.79). In the final adjusted model, we found that the risk of revision was significantly higher in patients receiving metal-on-metal (MoM: hazard ratio (HR) 1.93, p < 0.001) and ceramic-on-ceramic bearings (CoC: HR 1.55, p = 0.003) compared with the best performing bearing (metal-on-polyethylene). The risk of revision was also greater for smaller femoral stems (sizes 8 to 10: HR 1.82, p < 0.001) compared with mid-range sizes. In a secondary analysis of only patients where body mass index (BMI) data were available (n = 17 166), BMI ≥ 30 kg/m(2) significantly increased the risk of revision (HR 1.55, p = 0.002). The influence of the bearing on the risk of revision remained significant (MoM: HR 2.19, p < 0.001; CoC: HR 2.09, p = 0.001). The risk of revision was independent of age, gender, head size and offset, shell, liner and stem type, and surgeon characteristics. We found significant differences in failure between bearing surfaces and femoral stem size after adjustment for a range of covariates in a large cohort of single-brand cementless THRs. In this study of procedures performed since 2003, hard bearings had significantly higher rates of revision, but we found no evidence that head size had an effect. Patient characteristics, such as BMI and American Society of Anesthesiologists grade, also influence the survival of cementless components.

  18. Long-term retrospective study on the placement of the cementless acetabular cup and clinical outcomes in patients undergoing femoral head autografting for hip dysplasia and total hip arthroplasty.

    PubMed

    Ozden, Vahit Emre; Dikmen, Goksel; Beksac, Burak; Tozun, Ismail Remzi

    2018-05-01

    Placement of acetabular cup in the dysplastic hip is a challenging procedure. Using bulk femoral head autograft to increase the bony coverage of the cup is one of the techniques, which have been described. The impact of cup position on cup and autograft survival is a controversial issue. We aimed to determine whether the position of cementless acetabular cup used in conjunction with femoral head autograft in dysplastic hips affected the autograft-host incorporation with its final radiographic appearance and the cup survivorship into the second decade. Thirty-eight dysplastic hips with varying Crowe types in 31 patients (30 women and one man) were included. The mean age was 47 years (range, 29-64 years) and the mean follow-up was 20.3 years (range, 14.8-25.9 years). The initial postoperative and final radiographs were evaluated. The survival rate of the cups was analysed using Kaplan-Meier statistics and the log-rank test. Multivariate analysis was used to evaluate the effect of variables (Crowe type, radiographic initial host bone coverage over the cup and position of the cup) on survivorship. The acetabular cups were positioned anatomical in 27/38 hips according to Ranawat measurement technique. Trabecular bridging at graft-host interface was seen in all cases at an average 22.1 months. Neither acetabular cup position nor initial host bone coverage over acetabular cup less than 50% had any significant effect on either cup survival or final radiographic appearance of the graft. The 20-year cup survival rate without aseptic revision was 66% (95 CI, 52%-84%). No revision was performed due to graft resorption. Twenty-year survival rate of the cementless cup combination with femoral head autograft showed no significant differences whether it was placed at high or anatomic hip centre. The final radiographic appearance of the autograft was not affected from either the cup location or the initial radiographic horizontal host bone coverage. Copyright © 2018 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  19. Comparison of Outcomes of Total Hip Arthroplasty between Patients with Ankylosing Spondylitis and Avascular Necrosis of the Femoral Head.

    PubMed

    Lee, Sun-Ho; Lee, Gun-Woo; Seol, Young-Jun; Park, Kyung-Soon; Yoon, Taek-Rim

    2017-09-01

    The objective of this study was to compare clinical and radiological outcomes of total hip arthroplasty (THA) between ankylosing spondylitis (AS) of the hip joint and avascular necrosis (AVN) of the femoral head. Thirty patients (30 hips) underwent cementless THA for AS between 2003 and 2012. They were compared to 30 patients (30 hips) who underwent the same procedure for AVN of the femoral head. Each group was matched for age and gender, and both groups had similar preoperative demographic characteristics. All cases were followed for minimum 4 postoperative years. Clinical evaluation was based on operation time, intraoperative blood loss, quantity of postoperative drainage, Harris Hip Score (HHS), and range of motion (ROM). Radiological results were evaluated by acetabular cup anteversion and inclination, femoral stem orientation, pre- and postoperative leg length discrepancy, and postoperative complications. The operation time was significantly longer in the AS group (120.2 ± 26.2 min) than in the AVN group (79.5 ± 11.1 min). The volume of postoperative drainage was significantly greater in the AS group (764.5 ± 355.4 mL vs. 510.5 ± 195.6 mL). Preoperative HHS was lower in the AS group (55.6 ± 13.8 vs. 59.2 ± 2.8). Similarly, postoperative HHS was significantly lower in the AS group (92.8 ± 2.7 vs. 97.4 ± 2.6). The arc of ROM was improved from 146.5° ± 13.2° preoperatively to 254.7° ± 17.2° postoperatively in the AS group and from 182.6° ± 15.5° to 260.4° ± 13.7° in the AVN group. Implant position and postoperative leg length discrepancy were not different between the groups. However, three cases of heterotopic ossification was observed in the AS group, whereas only 1 case was found in the AVN group. One deep infection and one aseptic stem loosening were found in the AS group, whereas none was observed in the AVN group. Cementless THA showed satisfactory clinical and radiological results in both groups, despite the longer operation time, larger blood loss volume, and lower HHS score of the AS group. Our findings suggest that cementless THA is an effective and reliable treatment for both AS and AVN.

  20. Cementless total hip arthroplasty for severely dislocated hips previously treated with Schanz osteotomy of the proximal femur.

    PubMed

    Akman, Yunus Emre; Yavuz, Umut; Çetinkaya, Engin; Gür, Volkan; Gül, Murat; Demir, Bilal

    2018-03-01

    We report the short-term outcomes of total hip arthroplasty(THA) in patients previously treated with Schanz osteotomy (SO). Eighteen patients [2 male, 16 female; mean age, 55.4 (range, 50-66) years] who had undergone THA after SO were retrospectively evaluated. Clinical evaluation was performed based on the Harris hip score. Radiological evaluation was performed using full-length radiographs of the lower extremities, pelvis, and hip. The mean follow-up period was 30.8 (range, 18-56) months. Mean femoral shortening was 3.7 (range, 2-5) cm. Perioperative complications occurred in 4 (22.2%) patients. Nonunion was not found at the osteotomy sites. No dislocation was observed. The Trendelenburg sign was positive for five (27.7%) patients, postoperatively. The mean Harris hip score improved from 42.7 to 78.7 (p < 0.05). THA for hips previously treated with SO is technically demanding. If careful preoperative planning is performed, successful treatment can be achieved.

  1. Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty: a review of our experience.

    PubMed

    Callaghan, John J; O'Rourke, Michael R; Goetz, Devon D; Lewallen, David G; Johnston, Richard C; Capello, William N

    2004-12-01

    Constrained acetabular components have been used to treat certain cases of intraoperative instability and postoperative dislocation after total hip arthroplasty. We report our experience with a tripolar constrained component used in these situations since 1988. The outcomes of the cases where this component was used were analyzed for component failure, component loosening, and osteolysis. At average 10-year followup, for cases treated for intraoperative instability (2 cases) or postoperative dislocation (4 cases), the component failure rate was 6% (6 of 101 hips in 5 patients). For cases where the constrained liner was cemented into a fixed cementless acetabular shell, the failure rate was 7% (2 of 31 hips in 2 patients) at 3.9-year average followup. Use of a constrained liner was not associated with an increased osteolysis or aseptic loosening rate. This tripolar constrained acetabular liner provided total hip arthroplasty construct stability in most cases in which it was used for intraoperative instability or postoperative dislocation.

  2. Early radiological and functional outcomes for a cementless press-fit design modular femoral stem revision system.

    PubMed

    Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts

    2018-05-01

    To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.

  3. Highly Cross-Linked Polyethylene Reduces Osteolysis Incidence and Wear-Related Reoperation Rate in Cementless Total Hip Arthroplasty Compared With Conventional Polyethylene at a Mean 12-Year Follow-Up.

    PubMed

    Tsukamoto, Manabu; Mori, Toshiharu; Ohnishi, Hideo; Uchida, Soshi; Sakai, Akinori

    2017-12-01

    A number of studies on total hip arthroplasty have compared highly cross-linked polyethylene (HXLPE) with conventional polyethylene (CPE) liners beyond 10 years. However, the impact of HXLPE on the wear-related reoperation rate is unclear. The purpose of this study was to evaluate the clinical advantage of using a single manufacturer's HXLPE in terms of reducing the reoperation rate. The study was a follow-up retrospective cohort study over a mean of 12 years that examined patients aged 45-70 years with cementless total hip arthroplasty using a 26-mm-diameter cobalt-chromium head. Sixty-seven patients (79 hips; HXLPE group = 41 hips, CPE group = 38 hips) were evaluated for a minimum 10-year follow-up. Kaplan-Meier survival analysis was performed, with wear-related reoperations and radiographic osteolysis serving as the end points. The polyethylene wear rate was also assessed. The mean 12-year follow-up rates of survivorship that were evaluated using wear-related reoperations as the end point were 100% and 91.4% in the HXLPE and CPE groups, respectively (P = .007), and the mean 12-year follow-up rates of survivorship with osteolysis as the end point were 100% and 36.2%, respectively (P < .001). Compared with the CPE group, the HXLPE group presented a significantly reduced wear rate (HXLPE group, 0.035 mm/y; CPE group, 0.118 mm/y). A unique strength of this study is that we assessed a single manufacturer's HXLPE while keeping most other implant parameters uniform. This study reveals the clinical advantage of using a single manufacturer's HXLPE in terms of a reduced wear-related reoperation rate at a mean 12-year follow-up. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty.

    PubMed

    Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit

    2017-01-01

    Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al . on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al . is required for acetabular implants with eccentric holes for fixation of acetabular screws.

  5. Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

    PubMed

    Ferreira, André; Aslanian, Thierry; Dalin, Thibaud; Picaud, Jean

    2017-05-01

    Using a ceramic-ceramic bearings, cementless total hip arthroplasty (THA) has provided good clinical results. To ensure longevity a good quality fixation of the implants is mandatory. Different surface treatments had been used, with inconsistent results. We hypothesized that a "bilayer coating" applied to both THA components using validated technology will provide a long-lasting and reliable bone fixation. We studied the survival and bone integration of a continuous, single-surgeon, retrospective series of 126 THA cases (116 patients) with an average follow-up of 12.2 years (minimum 10 years). The THA consisted of cementless implants with a bilayer coating of titanium and hydroxyapatite and used a ceramic-ceramic bearing. With surgical revision for any cause (except infection) as the end point, THA survival was 95.1 % at 13 years. Stem (98.8 %) and cup (98.6 %) survival was similar at 13 years. Bone integration was confirmed in 100 % of implants (Engh-Massin score of 17.42 and ARA score of 5.94). There were no instances of loosening. Revisions were performed because of instability (1.6 %), prosthetic impingement or material-related issues. A bilayer titanium and hydroxyapatite coating provides strong, fast, reliable osseo integration, without deterioration at the interface or release of damaging particles. The good clinical outcomes expected of ceramic bearings were achieved, as were equally reliable stem and cup fixation.

  6. Prospective long-term follow-up of the cementless bicontact hip stem with plasmapore coating.

    PubMed

    Ochs, U; Eingartner, C; Volkmann, R; Ochs, B G; Huber, C; Weller, S; Weise, K

    2007-01-01

    A prospective long-term study of the first 250 cementless Bicontact stems implanted in the BG Trauma Centre, Tuebingen, Germany. All of the patients in this series (treatment period June 1987 to April 1990) who were still contactable were invited for clinical and radiological follow-up. The radiographs were analysed for signs of loosening in the form of Gruen lysis zones, stress shielding, subsidence behaviour, heterotopic ossification and spot welds. The average follow-up period was 17.8 (16.7 - 19.5) years. The overall rate of follow-up was 65 % (162 of 250) and 91 % of patients who were still alive (162 of 179). The average patient age was 56.2 years at the time of operation and 74.0 years at follow-up. The average HHS was 81.6 points. In the course of the first 10 years (up to 03/1998), a total of 8 stem revisions had to be performed. In the period from 03/1998 to 01/2007, 2 cases of loosening requiring revision occurred in the patients still alive at the time of follow-up. The survival rate calculated was thus 95.6 %. These outstanding results provide enduring support for the philosophy of the cementless and bone-preserving fixation principles underlying the Bicontact hip stem with proximal intertrochanteric transmission of forces and high primary rotational stability.

  7. The cementless anatomic medullary locking femoral component: an independent clinical and radiographic assessment

    PubMed Central

    Chess, David G.; Grainger, R. Wayne; Phillips, Tom; Zarzour, Zane D.; Sheppard, Bruce R.

    1996-01-01

    Objective To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. Design A clinical and radiographic review. Setting A tertiary lower limb joint replacement centre. Patients Two hundred and twenty-one patients with noninflammatory gonarthrosis. Interventions Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons. Main Outcome Measures Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill. Results Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases. Conclusion The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. PMID:8857987

  8. Global fit concept in revision hip arthroplasty for cementless press-fit femoral stems.

    PubMed

    Canovas, F; LeBeguec, P; Batard, J; Gaillard, F; Dagneaux, L

    2017-06-01

    A revision stem may be required after a femoral extended trochanteric osteotomy (ETO) is made during revision hip arthroplasty. The two main complications of straight cementless femoral stems are subsidence due to inadequate osteointegration and stress-shielding. We will describe an original revision method with ETO that uses a straight cementless stem. The goal of this method was to achieve the most extensive press-fit possible during stem implantation to improve the transmission of stresses to the bone and to prevent reduction in bone density. The intramedullary preparation was done after closure and fixation of the ETO, which allows impaction of the revision stem with metaphyseal and diaphyseal press-fit. We report encouraging results with preservation of periprosthetic bone stock and good osteointegration of these revision stems at the final follow-up. Pronounced sagittal curvature or large bone defects are contraindications for this technique. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. 10-year results of the uncemented Allofit press-fit cup in young patients.

    PubMed

    Streit, Marcus R; Weiss, Stefan; Andreas, Franziska; Bruckner, Thomas; Walker, Tilman; Kretzer, J Philippe; Ewerbeck, Volker; Merle, Christian

    2014-08-01

    Uncemented acetabular components in primary total hip arthroplasty (THA) are commonly used today, but few studies have evaluated their survival into the second decade in young and active patients. We report on a minimum 10-year follow-up of an uncemented press-fit acetabular component that is still in clinical use. We examined the clinical and radiographic results of our first 121 consecutive cementless THAs using a cementless, grit-blasted, non-porous, titanium alloy press-fit cup (Allofit; Zimmer Inc., Warsaw, IN) without additional screw fixation in 116 patients. Mean age at surgery was 51 (21-60) years. Mean time of follow-up evaluation was 11 (10-12) years. At final follow-up, 8 patients had died (8 hips), and 1 patient (1 hip) was lost to follow-up. 3 hips in 3 patients had undergone acetabular revision, 2 for deep infection and 1 for aseptic acetabular loosening. There were no impending revisions at the most recent follow-up. We did not detect periacetabular osteolysis or loosening on plain radiographs in those hips that were evaluated radiographically (n = 90; 83% of the hips available at a minimum of 10 years). Kaplan-Meier survival analysis using revision of the acetabular component for any reason (including isolated inlay revisions) as endpoint estimated the 11-year survival rate at 98% (95% CI: 92-99). Uncemented acetabular fixation using the Allofit press-fit cup without additional screws was excellent into early in the second decade in this young and active patient cohort. The rate of complications related to the liner and to osteolysis was low.

  10. [Ex vivo microCT analysis of possible microfractures of the femoral head during implantation of a cementless hip resurfacing femoral component].

    PubMed

    Lerch, M; Olender, G; von der Höh, N; Thorey, F; von Lewinski, G; Meyer-Lindenberg, A; Windhagen, H; Hurschler, C

    2009-01-01

    Microfractures of the femoral head during implantation of the femoral components are suspected to be a cause of fractures at the implant/neck junction which represent a common failure mode in hip resurfacing arthroplasty. Callus formation observed in femoral head retrievals suggests the occurrence of microfractures inside the femoral head, which might be inadvertently caused by the surgeon during implantation. The aim of this biomechanical study was to analyse whether or not the implantation of a cementless femoral component hip resurfacing system causes microfractures in the femoral head. After the preparation of 20 paired human cadaveric femoral heads, the cementless femoral component ESKA Typ BS (ESKA Implants GmbH & Co., Lübeck) was implanted on 9 specimens with an impaction device that generates 4.5 kN impaction force. On 9 specimens the femoral component was implanted by hand. One head was used as a fracture model, 1 specimen served as control without manipulation. The femoral component used for impaction was equipped with hinges to enable its removal without further interfering with the bone stock. Specimens were scanned with a microCT device before and after impaction and the microCT datasets before and after impaction were compared to identify possible microfractures. Twenty strikes per hand or with the impaction device provided sufficient implant seating. Neither the macroscopic examination nor the 2-dimensional microCT analysis revealed any fractures of the femoral heads after impaction. At least macroscopically and in the 2-dimensional microCT analysis, implantation of the cementless hip resurfacing femoral component ESKA Typ BS with 4.5 kN or by hand does not seem to cause fractures of the femoral head. Georg Thieme Verlag KG Stuttgart, New York.

  11. Pre-clinical evaluation of the mechanical properties of a low-stiffness cement-injectable hip stem.

    PubMed

    Eldesouky, Ibrahim; Harrysson, Ola; Marcellin-Little, Denis J; West, Harvey; El-Hofy, Hassan

    2017-11-01

    In total hip arthroplasty (THA), the femoral stem can be fixed with or without bone cement. Cementless stem fixation is recommended for young and active patients as it eliminates the risk of loss of fixation at the bone-cement and cement-implant interfaces. Cementless fixation, however, suffers from a relatively high early revision rate. In the current research, a novel low-stiffness hip stem was designed, fabricated and tested. The stem design provided the option to inject biodegradable bone cement that could enhance initial stem stability. The stem was made of Ti6Al4V alloy. The proximal portion of the stem was porous, with cubic cells. The stem was fabricated using electron beam melting (EBM) technology and tested in compression and bending. Finite-element analysis was used to evaluate stem performance under a dynamic load representing a stair descending cycle and compare it to the performance of a solid stem with similar geometry. The von Mises stresses and maximum principal strains generated within the bone increased after porous stem insertion compared to solid stem insertion. The low-modulus stem tested in this study has acceptable mechanical properties and generates strain patterns in bone that appear compatible with clinical use.

  12. Two- to 4-Year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

    PubMed

    Amendola, Richard L; Goetz, Devon D; Liu, Steve S; Callaghan, John J

    2017-02-01

    Short stem cementless femoral components were developed to aid insertion through smaller incisions, preserve metaphyseal bone, and potentially decrease or limit the incidence of thigh pain. Despite some clinical success, the senior author (DDG) believed a higher percentage of his patients who had received a cementless short stem design were experiencing thigh pain, which, coupled with concerns about bone ingrowth fixation, motivated the review of this case series. (1) What is the proportion of patients treated with a short stem cementless THA femoral component that develop thigh pain and what are the hip scores of this population? (2) What are the radiographic results, specifically with respect to bone ingrowth fixation and stress shielding, of this design? (3) Are there particular patient or procedural factors that are associated with thigh pain with this short stem design? Two hundred sixty-one primary THAs were performed in 238 patients by one surgeon between November 2010 and August 2012. During this time period, all patients undergoing primary THA by this surgeon received the same cementless short titanium taper stem. Seven patients (eight hips) died and five patients (five hips) were lost to followup, leaving 226 patients (248 hips) with a mean followup of 3 years (range, 2-5 years). Patients rated their thigh pain during activity or rest at final followup on a 10-point visual analog scale. Harris hip scores (HHS) were obtained at every clinic appointment. Thigh pain was evaluated at the final followup or by contacting the patient by phone. Radiographs were evaluated for bone-implant fixation, bone remodeling, and osteolysis. An attempt was made to correlate thigh pain with patient demographics, implant specifications, or radiographic findings. Seventy-six percent of hips (180 of 238) had no thigh pain, 16% of hips (37 of 238) had mild thigh pain, and 9% (21 of 238) had moderate or severe thigh pain. Preoperatively, mean HHS was 47 (SD, 16) and at last followup, mean HHS was 88 (SD, 13). There were two femoral revisions, one for severe thigh pain and the other for infection. All but two components demonstrated bone ingrowth fixation (99%). Femoral stress shielding was mild in 64% of hips (135 of 212), moderate in 0.5% (one of 212), and severe in no hips. There is an inverse linear relationship between age and severity of thigh pain (r = -0.196; p < 0.0024). Although reliable fixation was achieved and good HHS were attained, the frequency and severity of thigh pain with this short cementless stem were concerning. The surgeon has subsequently abandoned this short stem design and returned to a conventional length stem. Future study direction might investigate the biomechanical grounds for the thigh pain associated with this stem design. Level IV, therapeutic study.

  13. Possible Vascular Injury Due to Screw Eccentricity in Minimally Invasive Total Hip Arthroplasty

    PubMed Central

    Singh, Nishant Kumar; Rai, Sanjay Kumar; Rastogi, Amit

    2017-01-01

    Background: Vascular injury during minimally invasive total hip arthroplasty (THA) is uncommon, yet a well-recognized and serious issue. It emerges because of non-visibility of vascular structures proximal to the pelvic bone during reaming, drilling holes, and fixing of screws. Numerous studies have found that screw fixation during cementless THA is beneficial for the initial stability of cup; yet, no anatomical guidelines support angular eccentric screw fixation. Materials and Methods: In this study, we obtained the pelvic arterial-phase computed tomographic data of thirty eight humans and reconstructed the three-dimensional models of osseous and vessel structures. We performed the surgical simulation to fix these structures with cementless cups and screws with angular eccentricities. Results: The effect of screw eccentricities (angular eccentricities of ±17° and ±34°) on the vascular injury was determined. Measurement between screw and adjoining vessels was performed and analyzed statistically to ascertain a comparative risk study for blood vessels that are not visible during surgery. Conclusion: Authors similarly discussed the significant absence of appreciation of quadrant systems proposed by Wasielewski et al. on eccentric screws. Adjustment of quadrant systems provided by Wasielewski et al. is required for acetabular implants with eccentric holes for fixation of acetabular screws. PMID:28790474

  14. An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.

    PubMed

    Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia

    2015-09-01

    Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads.

    PubMed

    Nakahara, Ichiro; Nakamura, Nobuo; Nishii, Takashi; Miki, Hidenobu; Sakai, Takashi; Sugano, Nobuhiko

    2010-12-01

    We investigated the efficacy of combining highly cross-linked polyethylene with ceramic heads on further reduction in polyethylene wear compared with the combination with cobalt-chromium heads via PolyWare computer-assisted method. A prospective cohort study was performed on 102 cementless total hip arthroplasties using Longevity (Zimmer, Warsaw, Ind) highly cross-linked polyethylene liners. Either 26-mm zirconia heads or 26-mm cobalt-chromium heads were randomly used in 51 hips each. At a mean follow-up of 6.7 years, no significant differences were identified between the groups for total penetration rate and steady-state wear rate. Osteolysis was not observed in any hips in either group. In conclusion, no advantage was seen for the 26-mm zirconia head compared with the 26-mm cobalt-chromium head in this period. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. Hydroxyapatite in total hip arthroplasty. Our experience with a plasma spray porous titanium alloy/hydroxyapatite double-coated cementless stem.

    PubMed

    Castellini, Iacopo; Andreani, Lorenzo; Parchi, Paolo Domenico; Bonicoli, Enrico; Piolanti, Nicola; Risoli, Francesca; Lisanti, Michele

    2016-01-01

    Total hip arthroplasty could fail due to many factors and one of the most common is the aseptic loosening. In order to achieve an effective osseointegration and reduce risk of lossening, the use of cemented implant, contact porous bearing surface and organic coating were developed. Aim of this study was to evaluate clinical and radiological mid-term outcomes of a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem applied with "plasma spray" technique and to demonstrate the possibility to use this stem in different types of femoral canals. Between January 2008 and December 2012, 240 consecutive primary total hip arthroplasties (THAs) were performed using a porous titanium alloy/hydroxyapatite double coating manufactured cementless femoral stem. 182 patients were examined: 136 were females (74.7%) and 46 males (25.2%); average age was 72 years old (ranging from 26 to 92 years old). For each patient, Harris Hip Scores (HHS) and Womac Scores were collected. All X-ray images were analyzed in order to demonstrate stem survival rate and subsidence. Harris Hip Score was good or excellent in 85% of the cases (average 90%) and mean WOMAC score was 97.5 (ranging from 73.4 to 100). No cases of early/late infection or periprosthetic fracture were noticed, with an excellent implant survival rate (100%) in a mean period of 40 months (ranging from 24 and 84 months). 5 cases presented acute implant dislocation, 2 due to wrong cup positioning in a dysplastic acetabulum and 3 after ground level fall. Dorr classification of femoral geometry was uses and the results were: 51 type A bone, 53 type B bone and 78 type C bone. Stem subsidence over 2 mm was considered as a risk factor of future implant loosening and was evidenced in 3 female patients with type C of Dorr classification. No radiolucencies signs around the proximally coated portion of stem or proximal reabsorption were visible during the radiographic follow-up. Concerning the use of porous titanium alloy/hydroxyapatite double coating, this study reported an excellent implant survival rate in a mid-term period with a rate of 1,64% of subsidence in patients with type C of femoral canal but with an optimal HHS and Womac Score results. Regarding this stem, primary stability is guaranteed by trapezoid shape of proximal region and tapering in frontal plane through press-fit technique. Radiological absence of pedestal has been accepted as sign of no excessive stress transmission to distal cortex due to its tapered diaphyseal region. Thanks to the reported data, Authors can consider this double coating a valid choice with an excellent medium-term survival and encouraging subsidence results. Further studies are needed to ensure these results can be replicated.

  17. Different thermal conductivity in drilling of cemented compared with cementless hip prostheses in the treatment of periprosthetic fractures of the proximal femur: an experimental biomechanical analysis.

    PubMed

    Brand, Stephan; Klotz, Johannes; Hassel, Thomas; Petri, Maximilian; Ettinger, Max; Krettek, Christian; Goesling, Thomas; Bach, Friedrich-Wilhelm

    2013-10-01

    The purpose of this study was to evaluate the different temperature levels whilst drilling cemented and cementless hip prostheses implanted in bovine femora, and to evaluate the insulating function of the cement layer. Standard hip prostheses were implanted in bovine donor diaphyses, with or without a cement layer. Drilling was then performed using high-performance-cutting drills with a reinforced core, a drilling diameter of 5.5 mm and cooling channels through the tip of the drill for constantly applied internal cooling solution. An open type cooling model was used in this setup. Temperature was continuously measured by seven thermocouples placed around the borehole. Thermographic scans were also performed during drilling. At the cemented implant surface, the temperature never surpassed 24.7 °C when constantly applied internal cooling was used. Without the insulating cement layer (i.e. during drilling of the cementless bone-prosthesis construct), the temperature increased to 47 °C. Constantly applied internal cooling can avoid structural bone and soft tissue damage during drilling procedures. With a cement layer, the temperatures only increased to non-damaging levels. The results could be useful in the treatment of periprosthetic fractures with intraprosthetic implant fixation.

  18. Medium-term results of ceramic-on-polyethylene Zweymüller-Plus total hip arthroplasty.

    PubMed

    Li, H; Zhang, S; Wang, X M; Lin, J H; Kou, B L

    2017-08-01

    The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing. A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000. During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%). The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.

  19. Medium-term outcome in patients treated with total hip arthroplasty using a modular femoral stem.

    PubMed

    Dagnino, Augusto; Grappiolo, Guido; Benazzo, Franco M; Learmonth, Ian D; Spotorno, Lorenzo; Portinaro, Nicola

    2012-01-01

    The clinical, radiographic and quality of life results of total hip arthroplasty using the MODULUS cementless modular femoral stem were reviewed. 48 patients who had a total hip arthroplasty using the MODULUS femoral stem were identified. Six had bilateral procedures, resulting in 60 hips with complete clinical and radiographic data. Mean age at implantation was 50 years (range 33 to 82). Mean follow-up was 59 months (range 50 months to 73). There were two early post-operative dislocations (within 2 days). One patient required further surgery to remove heterotopic bone. Mean Harris Hip Score increased from 37 points preoperatively (range, 7 to 66) to 89 points at final review (range, 65 to 100 points). Radiographic evaluation revealed that all implants were stable without evidence of osteolysis but three patients (5%) exhibited heterotopic ossification. Quality of life was evaluated with the SF36. The physical component increased from 29.2 points (range, 18.5 to 46.0) to 51.7 points (range 42.9 to 60.6) and the mental component from 375 points (range, 19.5 to 50.0) to 50 points (range 32,8 to 62.0).

  20. Survival of cementless femoral components after osteonecrosis of the femoral head with different etiologies.

    PubMed

    Radl, Roman; Egner, Sigrun; Hungerford, Marc; Rehak, Peter; Windhager, Reinhard

    2005-06-01

    We reviewed 41 patients with 55 cementless total hip arthroplasty operated for advanced osteonecrosis. Patients were divided into 2 groups according to etiology of the osteonecrosis. The first group included 17 cases with osteonecrosis without a systemic disease and the second group 38 cases with osteonecrosis associated with a systemic disease. The follow-up was on average 6.4 years (range, 2-12.8). Eight (15.4%) stem revisions had to be performed; all of them were in the patients with a systemic disease. Ten-year survival rates with femoral revision as the endpoint were in the first group 100% and in the systemic disease group 68% (P = .03). The data of this retrospective study indicate a correlation between the survival of the femoral component and the etiology of the osteonecrosis.

  1. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    NASA Astrophysics Data System (ADS)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As patients are living longer and total hip arthroplasty is performed in younger patients the risks of osteolysis associated with cumulative wear is increased. Computer-assisted surgery is based on sensing feedback; vision and imaging that help surgeons align the patient's joints during total knee or hip replacement with a degree of accuracy not possible with the naked eye. For the first time, the computer feedback is essential for ligament balancing and longevity of the implants. The computers navigation systems also help surgeons to use smaller incisions instead of the traditional larger openings. Small-incision surgery offers the potential for faster recovery, less bleeding and less pain for patients. The development of SESCAN imaging technique to create a patient based model of a 3D joint will be presented to show the effective solution of complex geometry of joints.

  2. Bilateral non-traumatic acetabular and femoral neck fractures due to pregnancy-associated osteoporosis.

    PubMed

    Aynaci, Osman; Kerimoglu, Servet; Ozturk, Cagatay; Saracoglu, Metehan

    2008-03-01

    Pregnancy-associated osteoporosis is a rare disorder and its pathophysiology remains unknown. We report a case of pregnancy-associated osteoporosis in a 27-year-old primiparous patient who revealed bilateral hip pain during early postnatal period. The plain radiographs and computerized tomography showed bilateral femoral neck and acetabular fractures. The diagnosis of osteoporosis was established by bone mineral density. Diagnostic work-up excluded a secondary osteoporosis. The case was treated successfully by bilateral cementless total hip arthroplasty. Bone mineral density increased after 2 years of treatment with calcium-vitamin D, calcitriol and alendronate. Diagnosis of pregnancy-associated osteoporosis should be suspected when hip pain occurs during pregnancy or in the post-partum period as it can lead to acetabular and femoral neck fractures.

  3. Cancellous and cortical bone mineral density around an elastic press-fit socket in total hip arthroplasty.

    PubMed

    Pakvis, Dean F M; Heesterbeek, Petra J C; Severens, Marianne; Spruit, Maarten

    2016-12-01

    Background and purpose - The acetabular component has remained the weakest link in hip arthroplasty for achievement of long-term survival. One of the possible explanatory factors for acetabular failure has been acetabular stress shielding. For this, we investigated the effects of a cementless elastic socket on acetabular bone mineral density (BMD). Patients and methods - During 2008-2009, we performed a single-center prospective cohort trial on 25 patients (mean age 64 (SD 4), 18 females) in whom we implanted a cementless elastic press-fit socket. Using quantitative BMD measurements on CT, we determined the change in BMD surrounding the acetabular component over a 2-year follow-up period. Results - We found a statistically significant decrease in cancellous BMD (-14% to -35%) and a stable level of cortical BMD (5% to -5%) surrounding the elastic press-fit cup during the follow-up period. The main decrease was seen during the first 6 months after implantation. During the second year, cancellous BMD showed a further decrease in the medial and lower acetabular regions. Interpretation - We found no evidence that an elastic press-fit socket would prevent acetabular stress shielding during a 2-year follow-up.

  4. Bone density and functional results after femoral revision with a cementless press-fit stem.

    PubMed

    Canovas, F; Roche, O; Girard, J; Bonnomet, F; Goldschild, M; Le Béguec, P

    2015-05-01

    The influence of radiographic bone density changes in the area surrounding a total hip arthroplasty (THA) revision with a cementless press-fit stem is unknown, notably in terms of functional results. We have therefore conducted a study aiming to (1) propose a radiographic method to assess bone density, (2) measure the functional effects of reduced bone density, and (3) determine the factors contributing to these modifications. A reduction in radiographic bone density has a negative influence on the functional result after revision using a cementless press-fit stem. We retrospectively assessed 150 THA revisions at a mean follow-up of 6.3 ± 3.2 years (range, 2-15 years). The clinical assessment was based on the Harris Hip Score. Bone density modifications were measured radiographically and the method was evaluated. The change in bone density was classified into two groups: (1) bone density not reduced or < 2 Gruen zones (118 cases [79%]); (2) bone density reduced ≥ 2 zones (32 cases [21%]). The variables showing a potential influence were the Cortical Index (CI), the type of primary stability with the press-fit system, and the femoral implant length. Inter- and intraobserver reliability of radiographic bone density measurement was evaluated as moderate or good (Kappa, 0.58; 0.60 and 0.67, respectively). For the Harris Hip Score at follow-up, there was a borderline statistical relation between stages 1 and 2: for the 118 stage 1 patients, this score was 83.62 ± 11.54 (range, 27-99) versus 78.34 ± 15.98 (range, 62-91) for stage 2 patients (P = 0.09). A CI ≤ 0.44 showed mediocre bone quality contributing to decreased bone density (P < 0.02). On the other hand, there was no statistically significant relation with the type of primary fixation (P = 0.34) or the length of the implant (P = 0.23). A cementless revision femoral stem can induce a reduction in bone density with possible functional effects. The negative role played by bone scarcity on the functional score is confirmed, and even though the difference is not statistically significant, we suggest using a short stem when this is possible. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom.

    PubMed

    Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W

    2016-08-01

    The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. Management of an infected cementless cup with prosthetic retention and antibiotic therapy in a dog.

    PubMed

    Dan, B J; Kim, S E; Pozzi, A

    2014-11-01

    A two-year-old Rottweiler presented for acute onset of a right hindlimb lameness 20 weeks after a cementless total hip replacement (THR) and 16 weeks after open reduction to address luxation of the THR. Radiographs revealed periosteal proliferation of the medial acetabulum and a stable implant. Synovial fluid cytology was consistent with inflammatory joint fluid. Treatment consisted of surgical debridement and intravenous and oral antibiotics. THR implants were not removed. Culture of tissue removed from the THR site yielded growth of Pseudomonas and Staphylococcus species. Lameness resolved 2 months after surgery. Twenty months after surgery, the dog was exercising normally with no clinical lameness and pelvic radiographs revealed no evidence of implant loosening and markedly decreased periosteal reaction. To the authors' knowledge, this is the first report of an infected THR site successfully treated without prosthesis explantation in the dog. © 2014 British Small Animal Veterinary Association.

  7. High complication rate in reconstruction of Paprosky type IIIa acetabular defects using an oblong implant with modular side plates and a hook.

    PubMed

    Babis, G C; Sakellariou, V I; Chatziantoniou, A N; Soucacos, P N; Megas, P

    2011-12-01

    We report the results of 62 hips in 62 patients (17 males, 45 females) with mean age of 62.4 years (37 to 81), who underwent revision of the acetabular component of a total hip replacement due to aseptic loosening between May 2003 and November 2007. All hips had a Paprosky type IIIa acetabular defect. Acetabular revision was undertaken using a Procotyl E cementless oblong implant with modular side plates and a hook combined with impaction allografting. At a mean follow-up of 60.5 months (36 to 94) with no patients lost to follow-up and one died due to unrelated illness, the complication rate was 38.7%. Complications included aseptic loosening (19 hips), deep infection (3 hips), broken hook and side plate (one hip) and a femoral nerve palsy (one hip). Further revision of the acetabular component was required in 18 hips (29.0%) and a further four hips (6.4%) are currently loose and awaiting revision. We observed unacceptably high rates of complication and failure in our group of patients and cannot recommend this implant or technique.

  8. Migration characteristics and early clinical results of the NANOS® short-stem hip arthroplasty.

    PubMed

    Kaipel, Martin; Grabowiecki, Phillip; Sinz, Katrina; Farr, Sebastian; Sinz, Günter

    2015-05-01

    Femoral short stems promise essential advantages in total hip arthroplasty. Up to now, only short- and midterm clinical studies exist. Data on early stem migration that could predict later aseptic loosening at an early stage are rare. The purpose of this study was to assess migration patterns and clinical outcome 2 years after hip replacement by a metaphyseal anchored cementless short stem. Migration data and clinical results were prospectively assessed in 49 patients. Clinical outcome was measured using the Harris Hip Score (HHS). Migration analyses were performed using the computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) system. At 2 years after surgery, none of the implants needed revision, and HHS increased from 47.9 up to 98.1. Of 49 patients, 5 (10%) showed increased vertical stem migration (1.5 mm/2a) that might predict late aseptic loosening. Of 49 stems, 44 (90%) showed stable migration patterns indicating a beneficial long-term outcome. Results of this study confirm the excellent clinical data of previous works. Migration patterns strongly suggest that short-stem arthroplasty is not only an innovative but also a reliable strategy in total hip replacement.

  9. Handling the procurement of prostheses for total hip replacement: description of an original value based approach and application to a real-life dataset reported in the UK

    PubMed Central

    Messori, Andrea; Trippoli, Sabrina; Marinai, Claudio

    2017-01-01

    Objectives In most European countries, innovative medical devices are not managed according to cost–utility methods, the reason being that national agencies do not generally evaluate these products. The objective of our study was to investigate the cost-utility profile of prostheses for hip replacement and to calculate a value-based score to be used in the process of procurement and tendering for these devices. Methods The first phase of our study was aimed at retrieving the studies reporting the values of QALYs, direct cost, and net monetary benefit (NMB) from patients undergoing total hip arthroplasty (THA) with different brands of hip prosthesis. The second phase was aimed at calculating, on the basis of the results of cost–utility analysis, a tender score for each device (defined according to standard tendering equations and adapted to a 0–100 scale). This allowed us to determine the ranking of each device in the simulated tender. Results We identified a single study as the source of information for our analysis. Nine device brands (cemented, cementless, or hybrid) were evaluated. The cemented prosthesis Exeter V40/Elite Plus Ogee, the cementless device Taperloc/Exceed, and the hybrid device Exeter V40/Trident had the highest NMB (£152 877, £156 356, and £156 210, respectively) and the best value-based tender score. Conclusions The incorporation of value-based criteria in the procurement process can contribute to optimising the value for money for THA devices. According to the approach described herein, the acquisition of these devices does not necessarily converge on the product with the lowest cost; in fact, more costly devices should be preferred when their increased cost is offset by the monetary value of the increased clinical benefit. PMID:29259062

  10. Increased risk of revision of cementless stemmed total hip arthroplasty with metal-on-metal bearings

    PubMed Central

    Pedersen, Alma B; Mäkelä, Keijo; Eskelinen, Antti; Havelin, Leif Ivar; Furnes, Ove; Kärrholm, Johan; Garellick, Göran; Overgaard, Søren

    2015-01-01

    Background and purpose Data from the national joint registries in Australia and England and Wales have revealed inferior medium-term survivorship for metal-on-metal (MoM) total hip arthroplasty (THA) than for metal-on-polyethylene (MoP) THA. Based on data from the Nordic Arthroplasty Register Association (NARA), we compared the revision risk of cementless stemmed THA with MoM and MoP bearings and we also compared MoM THA to each other. Patients and methods We identified 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). The patients were followed until revision, death, emigration, or the end of the study period (December 31, 2011), and median follow-up was 3.6 (interquartile range (IQR): 2.4–4.8) years for MoM bearings and 3.4 (IQR: 2.0–5.8) years for MoP bearings. Multivariable regression in the presence of competing risk of death was used to assess the relative risk (RR) of revision for any reason (with 95% confidence interval (CI)). Results The cumulative incidence of revision at 8 years of follow-up was 7.0% (CI: 6.0–8.1) for MoM bearings and 5.1% (CI: 4.7–5.6) for MoP bearings. At 6 years of follow-up, the RR of revision for any reason was 1.5 (CI: 1.3–1.7) for MoM bearings compared to MoP bearings. The RR of revision for any reason was higher for the ASR (adjusted RR = 6.4, CI: 5.0–8.1), the Conserve Plus (adjusted RR = 1.7, CI: 1.1–2.5) and “other” acetabular components (adjusted RR = 2.4, CI: 1.5–3.9) than for MoP THA at 6 years of follow-up. Interpretation At medium-term follow-up, the survivorship for cementless stemmed MoM THA was inferior to that for MoP THA, and metal-related problems may cause higher revision rates for MoM bearings with longer follow-up. PMID:25715878

  11. High incidence of intraoperative calcar fractures with the cementless CLS Spotorno stem.

    PubMed

    Timmer, Carla; Gerhardt, Davey M J M; de Visser, Enrico; de Kleuver, Marinus; van Susante, Job L C

    2018-05-07

    This study reports on the incidence of intraoperative calcar fractures with the cementless Spotorno (CLS) stem, and the potential role of a learning curve and implant positioning is investigated. After introduction of the CLS stem, 800 consecutive cementless total hip arthroplasties (THA) were analyzed. The incidence of calcar fracture in the first 400 THA was compared with the second 400 THA, in order to study a potential learning curve effect. According to the instruction for users, varus positioning of the stem was avoided and a femoral neck osteotomy was aimed relatively close to the lesser trochanter since these are assumed to be correlated with calcar fractures. Implant positioning (neck-shaft angle, femoral offset and osteotomy-lesser trochanter distance) was measured on postoperative pelvic radiographs of all THA with calcar fractures and 100 randomly selected uncomplicated control cases. Seventeen (2.1%) intraoperative calcar fractures were recorded. The incidence of calcar fracture differed between the first 400 THA (n = 11) and the second 400 THA (n = 6). This difference was not statistically significant (p = 0.220); however, these numbers indicate a trend toward a learning effect. No significant difference in stem positioning nor the height of the femoral neck osteotomy was measured between THA with a calcar fracture (n = 17) and the control cases (n = 100). We report on a high incidence of intraoperative calcar fractures with the use of a CLS stem. The risk for calcar fractures remains clinically significant even after adequate implant positioning in the hands of experienced hip surgeons. Surgeons should be aware of this implant related phenomenon and be alert on this phenomenon intraoperatively.

  12. The cementless Bicontact stem in a prospective dual-energy X-ray absorptiometry study.

    PubMed

    Lerch, Matthias; Kurtz, Agnes; Windhagen, Henning; Bouguecha, Anas; Behrens, Bernd A; Wefstaedt, Patrick; Stukenborg-Colsman, Christina M

    2012-11-01

    The cementless Bicontact total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the Bicontact stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study. After power analysis, a consecutive series of 25 patients with unilateral Bicontact stem implantation was examined clinically and underwent DEXA examinations. Scans of seven regions of interest were taken preoperatively and at one week, six months, and one and two years. One patient required stem revision due to a deep infection. The Harris Hip Score increased significantly by 44 points. The most significant bone loss was observed in the calcar region (R7) in the first six months (-19.2 %). It recovered in the following 18 months to -8.5 %. The BMD in the greater trochanter dropped significantly after six months and remained stable at this level. BMD exceeded baseline values in distal regions and even more in the lesser trochanter region after two years. We conclude that the Bicontact stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the Bicontact system. Thus, we believe that this stem is still a state-of-the-art implant.

  13. [On the history of cementless implants in extremity surgery].

    PubMed

    Dufek, Pavel

    2017-05-01

    The aim of implantation of cementless hip prostheses is vital ingrowth of bone into the structured metal surface of the implant. Since the 1960s several implants with surfaces made of cobalt-based alloys have been produced for this purpose. In the 1980s a novel hip endoprosthesis with a spongiosa-metal surface was introduced. The three-dimensional ingrowth of bone tissue into the structured surface of the implant could be demonstrated both histologically and using scanning electron microscopy (SEM). These implants made of cobalt-based alloys can also be used in endo-exo prostheses. Titanium implants with a microstructured surface have also been used and very good osseintegration of the surface was also demonstrated by histomorphology. The optimization of the surface and design of the prostheses plays an increasingly more important role in the field of revision endoprostheses.

  14. Preparation of the Femoral Bone Cavity for Cementless Stems: Broaching vs Compaction. A Five-Year Randomized Radiostereometric Analysis and Dual Energy X-Ray Absorption Study.

    PubMed

    Hjorth, Mette H; Kold, Søren; Søballe, Kjeld; Langdahl, Bente L; Nielsen, Poul T; Christensen, Poul H; Stilling, Maiken

    2017-06-01

    Short-term experimental and animal studies have confirmed superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Forty-four hips in 42 patients (19 men) were randomly operated using cementless hydroxyapatite-coated Bi-Metric stems. Patients were followed with radiostereometric analysis at baseline, 6 and 12 weeks, 1, 2, and 5 years, and measurements of periprosthetic bone mineral density at baseline, 1, 2, and 5 years. Complications during the study period and clinical outcome measures of Harris Hip Score were recorded at mean 7 years (5-8.8) after surgery. Absolute migrations of medio/lateral translations between the broaching group and the compaction group of mean 0.14 mm (standard deviation [SD] 0.10) vs mean 0.30 mm (SD 0.27) (P = .01) at 1 year, and of mean 0.13 mm (SD 0.10) vs 0.34 mm (0.31) (P = .01) at 5 years were different. Absolute valgus/varus rotations of mean 0.12° (SD 0.13°) in the broaching group were less than mean 0.35° (0.45°) in the compaction group (P < .01) at 1 year, but at 5 years no difference was observed (P = .19). Subsidence and retroversion were similar between groups at all follow-ups (P > .13). The compaction group had significantly less bone loss than the broaching group in Gruen zone 3 (distal-lateral to the stem) at 1 and 5 years. No further differences in bone mineral density changes were found between groups up to 5 years after surgery. Complications throughout the period and clinical outcome measures of Harris Hip Score were similar at 7 years (5-8.8) after surgery. We found increased migration when preparing the bone with compaction compared with broaching in cementless femoral stems. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Matched cohort study of topical tranexamic acid in cementless primary total hip replacement.

    PubMed

    Sanz-Reig, Javier; Mas Martinez, Jesus; Verdu Román, Carmen; Morales Santias, Manuel; Martínez Gimenez, Enrique; Bustamante Suarez de Puga, David

    2018-03-29

    Tranexamic acid has been shown to be effective in reducing blood loss after total hip replacement. The purpose of this study was to prospectively assess the effectiveness of topical TXA use to reduce blood loss after primary total hip replacement and to compare these outcomes with those of a matched control group from a similar cohort that did not have received tranexamic acid. This is a prospective matched control study to assess the effect of a 2 g topical tranexamic acid in 50 mL physiological saline solution in total hip replacement. Primary outcomes were hemoglobin and hematocrit drop, and total blood loss. Secondary outcomes were transfusion rates, length of hospital stay, deep vein thrombosis, and pulmonary embolism events. We could match 100 patients to a control group. There were no statistical significantly differences between the two groups. The hemoglobin and hematocrit postoperative values were significantly higher in topical tranexamic acid group than in control group (P < 0.001). The mean total blood loss was 769 in topical tranexamic acid group and 1163 in control group with significant differences (P = 0.001), which meant 34% reduction in total blood loss. Length of stay was lower in topical tranexamic acid group. The risk of deep vein thrombosis and pulmonary events did not increase. A single dose of 2 g tranexamic acid in 50 mL physiological saline solution topical administration was effective and safe in reducing bleeding in patients undergoing unilateral primary non-cemented total hip replacement compared to a matched control group.

  16. [Total hip replacement with isoelastic prosthesis in animals (author's transl)].

    PubMed

    Muhr, O; Stockhusen, H; Müller, O

    1976-10-08

    Uncemented fixation and low-fraction materials are the basis of this experiment. Plastics with an elasticity similar to the bone ("isoelasticity") show very propitious material qualities. The direct cementless incorporation of test bodies must be checked. In 63 sheep isoelastic total hip joints were implanted. After 2 till 51 weeks the animals were sacrificed and 44 specimen of hips and organs were explored macroscopically, radiologically, spherimetrically and histologically. The result was: 1. Plastic hip prosthesis are incorporated in the bone, but the boundary layer is built by a collagenous fiber tissue. 2. Loosening brings resoption of the bone and expansion of the structural changed soft tissue. 3. The transformation of the femoral cortex to osteoporosis is considered possibly as the consequence of an insufficient biological transfer of the weight. 4. Fractures of the femoral prosthesis-stem could not be observed. 5. The radiology allows at the pelvis prosthesis a concret statement concerning stability, on the femoral part a probable one. 6. The abrasion is minimal, the tissue reaction to abrasion products is unessential. 7. Small abrasion particles are carried of by the lymph tract and stored in the first regional gland. A more distant spreading is not demonstrable.

  17. Incidence of Heterotopic Ossification after Surface and Conventional Total Hip Arthroplasty: A Comparative Study Using Anterolateral Approach and Indomethacin Prophylaxis

    PubMed Central

    Sandri, Andrea; Sambugaro, Elena

    2013-01-01

    The incidence and severity of heterotopic ossification (HO) in two homogeneous groups of patients that received surface replacement arthroplasty (SRA) and conventional total hip arthroplasty (THA) were evaluated retrospectively. Thirty-nine patients undergoing 42 hip resurfacing procedures and 41 primary cementless THAs through an anterolateral approach received a 10-day course of 150 mg/die of indomethacin postoperatively. The median surgical time was 190 minutes and 156 minutes, respectively (P < 0.003). At a minimum 1-year followup, the development of HO was assessed on standard X-ray using Brooker grading. Ectopic bone formation was detected in five cases (11.9%, two Brooker grade I and three grade II) in the SRA group and in 14 hips (34.1%, 12 grade I and two grade II) treated with conventional THA, but the difference was not significant (P < 0.11). No clinically relevant periprosthetic ossification (Brooker III or IV) occurred in both groups. Although the difference was not statistically significant, the incidence of HO after SRA was lower than conventional THA. More extensive soft tissue trauma, bone debris, and longer operative time in hip resurfacing are not likely to be absolute risk factors for HO. Further investigations including larger patient populations are needed to confirm these findings. PMID:23865045

  18. Fixation of Trochanteric Fragments in Cementless Bipolar Hemiarthroplasty of Unstable Intertrochanteric Fracture: Cerclage Wiring

    PubMed Central

    Lee, Young-Kyun; Koo, Kyung-Hoi

    2017-01-01

    Purpose Bipolar hemiarthroplasty (HA) is an option for the treatment of unstable intertrochanteric fracture in elderly patients. There is a raising concern regarding cable-grip related complications for the fixation of trochanteric fragments. Therefore, the aim of this study was to evaluate outcome of cementless HA with fixation for the trochanteric fragments using monofilament wires in unstable intertrochanteric fracture. Materials and Methods We reviewed 92 cementless bipolar HAs using a grit-blasted long stem design for unstable intertrochanteric fractures in 91 elderly patients with a mean age of 81.7 years. During the arthroplasty, trochanteric fracture fragments were fixed using 1 or 2 vertical wires and transverse wires. We evaluated the clinical outcomes such as abductor power, ambulatory ability and wire-related complications, and radiologic outcomes including the union of the trochanteric fragment and subsidence of stem. Results Sixty-two patients were followed for a minimum of 2 years (mean, 59 months) postoperatively. The mean abductor power and Koval category was 4.1 (range, 3 to 5) and 4.6 (range, 1 to 6). The wire was broken in 3 hips (4.8%) and the nonunion of the greater trochanter occurred in 1 hips (1.6%). Two stems subsided by 3 mm and 8 mm, respectively, during postoperative 6 weeks, after which the subsidence was not progressive. Conclusion Cerclage wiring of the trochanter using monofilament wire leads to acceptable outcome in cementless HA for senile patients with unstable intertrochanteric fracture. Cerclage wiring using a monofilament wire is recommended for the fixation of trochanteric fragments. PMID:29250501

  19. Computational Evaluation of the Effects of Bone Ingrowth on Bone Resorptive Remodeling after a Cementless Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Jung, Duk-Young; Kang, Yu-Bong; Tsutsumi, Sadami; Nakai, Ryusuke; Ikeuchi, Ken; Sekel, Ron

    In this study, we simulated a wide cortex separation from a cementless hip prosthesis using the bone resorption remodeling method that is based on the generation of high compressive stress around the distal cortical bone. Thereafter, we estimated the effect on late migration quantities of the hip prosthesis produced by the interface state arising from bone ingrowth. This was accomplished using cortical bone remodeling over a long period of time. Two-dimensional natural hip and implanted hip FEM models were constructed with each of the following interface statements between the bone and prosthesis: (1) non-fixation, (2) proximal 1/3, (3) proximal 2/3 and (4) full-fixation. The fixation interfaces in the fully and partially porous coated regions were rigidly fixed by bony ingrowth. The non-fixation model was constructed as a critical situation, with the fibrous or bony tissue not integrated at all into the implant surface. The daily load history was generated using the three loading cases of a one-legged stance as well as abduction and adduction motions. With the natural hip and one-legged stance, the peak compressive principal stresses were found to be under the criteria value for causing bone resorption, while no implant movement occurred. The migration magnitude of the stem of the proximal 1/3 fixation model with adduction motion was much higher, reaching 6%, 11%and 21%greater than those of the non-fixation, proximal 2/3 fixation and all-fixation models, respectively. The full-fixation model showed the lowest compressive principal stress and implant movement. Thus, we concluded that the late loosening and subsequent movement of the stem in the long term could be estimated with the cortical bone remodeling method based on a high compressive stress at the bone-implant interface. The change caused at the bone-prosthesis interface by bony or fibrous tissue ingrowth constituted the major factor in determining the extent of cortical bone resorption occurring with clinical loosening and subsequent implant movement.

  20. [Technology of cementless hip endoprosthetics].

    PubMed

    Ungethüm, M; Blömer, W

    1987-06-01

    The success achieved with non-cemented hip arthroplasty depends mainly on the stability of the fixation, the quality of the stabilizing bone being just as important as favourable biomechanical conditions. The results of the intensive research and development with respect to the particular features of a non-cemented hip endoprosthesis can be divided into the following basic categories: Biomechanical aspects with special reference to bone related to the design of the prosthesis; material characteristics, such as fatigue strength, tribology, corrosion resistance, and biocompatibility; and development of new materials and coatings to permit direct bonding of implant and bone. With regard to the stem of hip prostheses, the different design parameters of various types are examined to determine their typical design characteristics, such as bearing surface of the collar, geometry of cross section, anatomically adapted shaping, and surface of the implant forming the contact with the bone. The latter can be divided into macroprofiles and macro- and micro-porous coated surfaces. On the other hand, the methods of cementless fixation of acetabular cups can be primarily divided into conical and spherical screw fixation and pegged fixation with additional macroprofiles of porous surfaces. In a separate study of the biomechanical aspects of screwed sockets, the special importance of socket shape and thread geometry are presented with reference to primary stability and long-term fixation of prostheses.

  1. Total hip arthroplasty survival in femoral head avascular necrosis versus primary hip osteoarthritis: Case-control study with a mean 10-year follow-up after anatomical cementless metal-on-metal 28-mm replacement.

    PubMed

    Ancelin, D; Reina, N; Cavaignac, E; Delclaux, S; Chiron, P

    2016-12-01

    Total hip arthroplasty is the most widely used procedure to treat avascular necrosis (AVN) of the femoral head. Few studies have compared the outcomes of THA in femoral head AVN and primary hip osteoarthritis. Therefore we performed a case-control study to compare THA for femoral head AVN vs. primary hip osteoarthritis in terms of: (1) prosthesis survival, (2) complication rates, (3) functional outcomes and radiographic outcomes, (4) and to determine whether specific risk factors for THA failure exist in femoral head AVN. THA survival is similar in femoral head AVN and primary hip osteoarthritis. We compared two prospective cohorts of patients who underwent THA before 65 years of age, one composed of cases with femoral head AVN and the other of controls with primary hip osteoarthritis. In both cohorts, a cementless metal-on-metal prosthesis with a 28-mm cup and an anatomical stem was used. Exclusion criteria were THA with other types of prosthesis, posttraumatic AVN, and secondary osteoarthritis. With α set at 5%, to obtain 80% power, 246 patients were required in all. Prosthesis survival was assessed based on time to major revision (defined as replacement of at least one implant fixed to bone) and time to aseptic loosening. The other evaluation criteria were complications, Postel-Merle d'Aubigné (PMA) score, and the Engh and Agora Radiographic Assessment (ARA) scores for implant osseointegration. The study included 282 patients, 149 with AVN and 133 with osteoarthritis. Mean age was 47.8±10.2 years (range, 18.5-65) and mean follow-up was 11.4±2.8 years (range, 4.5-18.3 years). The 10-year survival rates were similar in the two groups: for major revision, AVN group, 92.5% (95% confidence interval [95% CI], 90.2-94.8) and osteoarthritis group, 95.3% (95% CI, 92.9-97.7); for aseptic loosening, AVN group, 98.6% (95% CI, 97.6-98.6) and osteoarthritis, 99.2% (95% CI, 98.4-100). The AVN group had higher numbers of revision for any reason (19 vs. 6, P=0.018) and for dislocation (8 vs. 1, P=0.031). Mean PMA scores at last follow-up were comparable in the AVN group (17.65±1.27 [range, 10-18]) and osteoarthritis group (17.59±1.32 [range, 14-18]) (P=0.139). Osseointegration was also similar in the two groups: global Engh score, 26.51±1.81 (range, 14-27) for AVN and 26.84±0.91 (range, 19.5-27) for osteoarthritis (P=0.065); femoral ARA score, 5.83±0.46 (range, 3-6) for AVN and 5.90±0.42 (range, 3-6) for osteoarthritis (P=0.064); and cup ARA score, 5.74±0.67 (range, 3-6) for AVN and 5.78±0.66 (range, 3-6) for osteoarthritis (P=0.344). Survival in this study was good and consistent with recent data on AVN, with no difference between AVN and osteoarthritis. Revisions for any cause or for dislocation were more common after THA for AVN. Functional outcomes were similar in the AVN and osteoarthritis groups. An anatomical cementless prosthesis combined with metal-on-metal 28-mm bearing provides durable good outcomes. III, non-randomized comparison of two prospective cohorts. Published by Elsevier Masson SAS.

  2. Revision Rates after Primary Hip and Knee Replacement in England between 2003 and 2006

    PubMed Central

    Sibanda, Nokuthaba; Copley, Lynn P; Lewsey, Jim D; Borroff, Mick; Gregg, Paul; MacGregor, Alex J; Pickford, Martin; Porter, Martyn; Tucker, Keith; van der Meulen, Jan H

    2008-01-01

    Background Hip and knee replacement are some of the most frequently performed surgical procedures in the world. Resurfacing of the hip and unicondylar knee replacement are increasingly being used. There is relatively little evidence on their performance. To study performance of joint replacement in England, we investigated revision rates in the first 3 y after hip or knee replacement according to prosthesis type. Methods and Findings We linked records of the National Joint Registry for England and Wales and the Hospital Episode Statistics for patients with a primary hip or knee replacement in the National Health Service in England between April 2003 and September 2006. Hospital Episode Statistics records of succeeding admissions were used to identify revisions for any reason. 76,576 patients with a primary hip replacement and 80,697 with a primary knee replacement were included (51% of all primary hip and knee replacements done in the English National Health Service). In hip patients, 3-y revision rates were 0.9% (95% confidence interval [CI] 0.8%–1.1%) with cemented, 2.0% (1.7%–2.3%) with cementless, 1.5% (1.1%–2.0% CI) with “hybrid” prostheses, and 2.6% (2.1%–3.1%) with hip resurfacing (p < 0.0001). Revision rates after hip resurfacing were increased especially in women. In knee patients, 3-y revision rates were 1.4% (1.2%–1.5% CI) with cemented, 1.5% (1.1%–2.1% CI) with cementless, and 2.8% (1.8%–4.5% CI) with unicondylar prostheses (p < 0.0001). Revision rates after knee replacement strongly decreased with age. Interpretation Overall, about one in 75 patients needed a revision of their prosthesis within 3 y. On the basis of our data, consideration should be given to using hip resurfacing only in male patients and unicondylar knee replacement only in elderly patients. PMID:18767900

  3. Usefullness of three-dimensional templating software to quantify the contact state between implant and femur in total hip arthroplasty.

    PubMed

    Inoue, Daisuke; Kabata, Tamon; Maeda, Toru; Kajino, Yoshitomo; Fujita, Kenji; Hasegawa, Kazuhiro; Yamamoto, Takashi; Takagi, Tomoharu; Ohmori, Takaaki; Tsuchiya, Hiroyuki

    2015-12-01

    It would be ideal if surgeons could precisely confirm whether the planned femoral component achieves the best fit and fill of implant and femur. However, the cortico-cancellous interfaces can be difficult to standardize using plain radiography, and therefore, determining the contact state is a subjective decision by the examiner. Few reports have described the use of CT-based three-dimensional templating software to quantify the contact state of stem and femur in detail. The purpose of this study was to use three-dimensional templating software to quantify the implant-femur contact state and develop a technique to analyze the initial fixation pattern of a cementless femoral stem. We conducted a retrospective review of 55 hips in 53 patients using a short proximal fit-and-fill anatomical stem (APS Natural-Hip™ System). All femurs were examined by density mapping which can visualize and digitize the contact state. We evaluated the contact state of implant and femur by using density mapping. The varus group (cases that had changed varus 2° by 3 months after surgery) consisted of 11 hips. The varus group showed no significant difference with regard to cortical contact in the proximal medial portion (Gruen 7), but the contact area in the distal portion (Gruen 3 and Gruen 5) was significantly lower than that of non-varus group. Density mapping showed that the stem only has to be press-fit to the medial calcar, but also must fill the distal portion of the implant in order to achieve the ideal contact state. Our results indicated that quantifying the contact state of implant and femur by using density mapping is a useful technique to accurately analyze the fixation pattern of a cementless femoral stem.

  4. Titanium-Based Hip Stems with Drug Delivery Functionality through Additive Manufacturing.

    PubMed

    Bezuidenhout, Martin B; Dimitrov, Dimitar M; van Staden, Anton D; Oosthuizen, Gert A; Dicks, Leon M T

    2015-01-01

    Postoperative infections are a major concern in patients that receive implants. These infections generally occur in areas with poor blood flow and pathogens do not always respond to antibiotic treatment. With the latest developments in nanotechnology, the incorporation of antibiotics into prosthetic implants may soon become a standard procedure. The success will, however, depend on the ability to control the release of antibiotics at concentrations high enough to prevent the development of antibiotic-resistant strains. Through additive manufacturing, antibiotics can be incorporated into cementless femoral stems to produce prosthetic devices with antimicrobial properties. With the emerging increase in resistance to antibiotics, the incorporation of antimicrobial compounds other than antibiotics, preferably drugs with a broader spectrum of antimicrobial activity, will have to be explored. This review highlights the microorganisms associated with total hip arthroplasty (THA), discusses the advantages and disadvantages of the latest materials used in hip implants, compares different antimicrobial agents that could be incorporated, and addresses novel ideas for future research.

  5. Titanium-Based Hip Stems with Drug Delivery Functionality through Additive Manufacturing

    PubMed Central

    Bezuidenhout, Martin B.; Dimitrov, Dimitar M.; van Staden, Anton D.; Oosthuizen, Gert A.; Dicks, Leon M. T.

    2015-01-01

    Postoperative infections are a major concern in patients that receive implants. These infections generally occur in areas with poor blood flow and pathogens do not always respond to antibiotic treatment. With the latest developments in nanotechnology, the incorporation of antibiotics into prosthetic implants may soon become a standard procedure. The success will, however, depend on the ability to control the release of antibiotics at concentrations high enough to prevent the development of antibiotic-resistant strains. Through additive manufacturing, antibiotics can be incorporated into cementless femoral stems to produce prosthetic devices with antimicrobial properties. With the emerging increase in resistance to antibiotics, the incorporation of antimicrobial compounds other than antibiotics, preferably drugs with a broader spectrum of antimicrobial activity, will have to be explored. This review highlights the microorganisms associated with total hip arthroplasty (THA), discusses the advantages and disadvantages of the latest materials used in hip implants, compares different antimicrobial agents that could be incorporated, and addresses novel ideas for future research. PMID:26504776

  6. Bilateral Femoral Neck Fractures in Cerebrotendinous Xanthomatosis Treated by Hip Arthroplasties: The First Case Report and Literature Review.

    PubMed

    Wejjakul, Witchuree; Chatmaitri, Swist; Wattanarojanaporn, Thongek; Pongkunakorn, Anuwat; Ittiwut, Chupong; Shotelersuk, Vorasuk

    2017-01-01

    Cerebrotendinous xanthomatosis (CTX) is a rare autosomal recessive lipid storage disease caused by mutations of the CYP27A1 gene and deficiency of the sterol-27-hydroxylase enzyme in bile acid biosynthesis. It is characterized by the accumulation of cholestanol and bile alcohols in plasma, the formation of xanthomatous lesions in various tissues, and organ degeneration. This disorder is also associated with osteoporosis and increased risk of fracture. To date, only two CTX patients with femoral neck fractures have been reported. Neither was treated by arthroplasties, and the operative outcomes are lacking. We report the case of a 46-year-old Thai female who presented with consecutive bilateral femoral neck fractures following minor trauma within a 3-year period and received cementless bipolar hemiarthroplasties. Her phenotypic expression included Achilles tendon masses, childhood-onset cataracts, intellectual disability, and cerebellar ataxia. A brain computed tomography showed non-enhancing hypodense lesions in the bilateral cerebellar hemispheres with mild brain atrophy. Histopathology from an Achilles tendon biopsy revealed tendinous xanthoma and molecular analysis confirmed a homozygous nonsense mutation, c.1072C>T (p.Gln358Ter), in exon 6 of the CYP27A1 gene. The intra-operative crack of a calcar femorale was a major complication during both prosthetic insertion surgeries and warranted cerclage wiring. At the 7-month follow-up of the right hip and the 41-month follow-up of the left hip, postoperative radiographs showed well-fixed and well-aligned prostheses. Independent household ambulation could be resumed with Harris hip scores of 81 points equally. CTX is associated with osteoporosis, and middle-aged patients could present with femoral neck fracture following minor trauma. Cementless bipolar hemiarthroplasty for a totally displaced fracture is justified for a patient who has cognitive impairment. Intra-operative fracture is a major complication during prosthetic insertion and warrants cerclage wiring to achieve predictable bone healing and a satisfactory result.

  7. The Frank Stinchfield Award: the impact of socioeconomic factors on outcome after THA: a prospective, randomized study.

    PubMed

    Allen Butler, R; Rosenzweig, Seth; Myers, Leann; Barrack, Robert L

    2011-02-01

    Most studies of total hip arthroplasty (THA) focus on the effect of the type of implant on the clinical result. Relatively little data are available on the impact of the patient's preoperative status and socioeconomic factors on the clinical results following THA. We determined the relative importance of patient preoperative and socioeconomic status compared to implant and technique factors in predicting patient outcome as reflected by scores on commonly utilized rating scales (eg, Harris Hip Score, WOMAC, SF-12, degree of patient satisfaction, or presence or severity of thigh pain) following cementless THA. All patients during the study period were offered enrollment in a prospective, randomized study to receive either a titanium, tapered, proximally coated stem; or a Co-Cr, cylindrical, extensively coated stem; 102 patients were enrolled. We collected detailed patient data preoperatively including diagnosis, age, gender, insurance status, medical comorbidities, tobacco and alcohol use, household income, educational level, and history of treatment for lumbar spine pathology. Clinical evaluation included Harris Hip Score, SF-12, WOMAC, pain drawing, and UCLA activity rating and satisfaction questionnaire. Implant factors included stem type, stem size, fit in the canal, and stem-bone stiffness ratios. Minimum 2 year followup was obtained in 95% of the enrolled patients (102 patients). Patient demographics and preoperative status were more important than implant factors in predicting the presence of thigh pain, dissatisfaction, and a low hip score. The most predictive factors were ethnicity, educational level, poverty level, income, and a low preoperative WOMAC score or preoperative SF-12 mental component score. No implant parameter correlated with outcome or satisfaction. Socioeconomic factors and preoperative status have more impact on the clinical outcome of cementless THA than implant related factors. Level I, prospective, randomized clinical trial. See the guidelines online for a complete description of level of evidence.

  8. Development and verification of a cementless novel tapered wedge stem for total hip arthroplasty.

    PubMed

    Faizan, Ahmad; Wuestemann, Thies; Nevelos, Jim; Bastian, Adam C; Collopy, Dermot

    2015-02-01

    Most current tapered wedge hip stems were designed based upon the original Mueller straight stem design introduced in 1977. These stems were designed to have a single medial curvature and grew laterally to accommodate different sizes. In this preclinical study, the design and verification of a tapered wedge stem using computed tomography scans of 556 patients are presented. The computer simulation demonstrated that the novel stem, designed for proximal engagement, allowed for reduced distal fixation, particularly in the 40-60 year male population. Moreover, the physical micromotion testing and finite element analysis demonstrated that the novel stem allowed for reduced micromotion. In summary, preclinical data suggest that the computed tomography based stem design described here may offer enhanced implant fit and reduced micromotion. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. A cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.

    PubMed

    Busch, Vincent J J F; Verschueren, Joost; Adang, Eddy M; Lie, Stein A; Havelin, Leif I; Schreurs, Berend W

    2016-01-01

    Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? We designed a decision model for a cost-utility analysis of a cemented cup with acetabular impaction bone grafting versus an uncemented cup, in terms of cost per quality-adjusted life year (QALY) for the young adult with acetabular bone deficiency, in need for a primary total hip arthroplasty. Outcome probabilities and effectiveness were derived from the Radboud University Nijmegen Medical Centre and the Norwegian Hip Register. Multiple sensitivity analyses were used to assess the contribution of the included variables in the model's outcome. Cemented cups with impaction bone grafting were more cost-effective compared to the uncemented option in terms of costs per QALY. A scenario suggesting equal primary survival rates of both cemented and uncemented cups still showed an effect gain of the cemented cup with impaction bone grafting, but at higher costs. Based on this model, the first choice of treatment of the acetabular bone deficient osteoarthritic hip in a young patient is reconstruction with impaction bone grafting and a cemented cup.

  10. [Dislocated fracture of the lesser trochanter with malrotation of the stem after robot assisted implantation of a cementless hip prosthesis: a casuistic report].

    PubMed

    Prymka, M; Hassenpflug, J

    2003-08-01

    This paper presents the case of a 63 year old female with a severe coxarthrosis. She got a robot assited implantation of a cementless hip prosthesis (Osteolock, Stryker-Howmedica, Mühlheim). As operation robot the CASPAR-System (Orto-Maquet, Rastatt) was used. Initially, the clinical progress of the patient was fine. She was nearly painfree within 14 days and showed an acceptable range of motion in the operated joint (flexion/ extension 90 degrees /05 degrees /00 degrees ). She was mobilized with crutches and 15 kg weight bearing at the operated leg. 3 weeks postoperative the patient complaint about increasing pain without trauma or intensification of the weight bearing. X-rays showed not only a dislocated fracture of the lesser trochanter, but also a sinking combined with a malrotation of the stem. A revision operation was necessary,where we implanted a cemented stem. Now clinical progress was completely satisfying.

  11. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Lee, Y K; Ha, Y C; Yoo, J-I; Jo, W L; Kim, K-C; Koo, K H

    2017-06-01

    We conducted a prospective study of a delta ceramic total hip arthroplasty (THA) to determine the rate of ceramic fracture, to characterise post-operative noise, and to evaluate the mid-term results and survivorship. Between March 2009 and March 2011, 274 patients (310 hips) underwent cementless THA using a delta ceramic femoral head and liner. At each follow-up, clinical and radiological outcomes were recorded. A Kaplan-Meier analysis was undertaken to estimate survival. Four patients (four hips) died and 18 patients (20 hips) were lost to follow-up within five years. The remaining 252 patients (286 hips) were followed for a mean of 66.5 months (60 to 84). There were 144 men (166 hips) and 108 women (120 hips) with a mean age of 49.7 years (16 to 83) at surgery. The mean pre-operative Harris Hip Score of 47.1 points improved to 93.8 points at final follow-up. Six patients reported squeaking in seven hips; however, none were audible. Radiolucent lines involving Gruen zones one and/or seven were seen in 52 hips (18.2%). No hip had detectable wear, focal osteolysis or signs of loosening. One hip was revised because of fracture of the ceramic liner, which occurred due to an undetected malseating of the ceramic liner at the time of surgery. One hip was revised for a periprosthetic fracture of the femur, and one hip was treated for periprosthetic joint infection. The six-year survivorship with re-operation for any reason as the endpoint was 99.0% (95% confidence interval 97.8% to 100%). The rate of delta ceramic fracture was 0.3% (one of 286). While ceramic head fracture was dominant in previous ceramic-on-ceramic THA, fracture of the delta ceramic liner due to malseating is a concern. Cite this article: Bone Joint J 2017;99-B:741-8. ©2017 The British Editorial Society of Bone & Joint Surgery.

  12. Uncemented total hip arthroplasty in chronic hemodialysis patients

    PubMed Central

    Li, Wei-Chun; Shih, Chun-Hsiung; Ueng, Steve W; Shih, Hsin-Nung; Lee, Mel S

    2010-01-01

    Background and purpose Whether or not uncemented total hip arthroplasty (THA) can achieve durable fixation of implants to bone in patients on chronic hemodialysis is unknown. We analyzed the 2–13-year clinical outcomes of cementless THA in patients with end-stage renal diseases who were maintained on long-term hemodialysis. Patients and methods We reviewed the outcome of 23 consecutive uncemented THAs undertaken between 1993 and 2004, in patients with chronic renal failure who had been on long-term hemodialysis (2–18 years). 1 patient died and 2 patients were lost to follow-up within 2 years, leaving 20 hips (20 patients, median age 66 (38–81) years at the time of THA, 11 females) that were reviewed at median 7 (2–13) years postoperatively. Results Radiographic bone-ingrowth fixation of the components was found in 19 patients. 1 patient had aseptic loosening requiring revision surgery. The median d'Aubigne and Postel score was 10 (8–14) preoperatively and 15 (12–18) at final review. No prosthetic infections were found in any of the patients. Interpretation Uncemented THA shows promising medium-term results in patients receiving long-term hemodialysis. PMID:20175645

  13. Does osteoporosis reduce the primary tilting stability of cementless acetabular cups?

    PubMed

    von Schulze Pellengahr, Christoph; von Engelhardt, Lars V; Wegener, Bernd; Müller, Peter E; Fottner, Andreas; Weber, Patrick; Ackermann, Ole; Lahner, Matthias; Teske, Wolfram

    2015-04-21

    Cementless hip cups need sufficient primary tilting stability to achieve osseointegration. The aim of the study was to assess differences of the primary implant stability in osteoporotic bone and in bone with normal bone density. To assess the influence of different cup designs, two types of threaded and two types of press-fit cups were tested. The maximum tilting moment for two different cementless threaded cups and two different cementless press-fit cups was determined in macerated human hip acetabuli with reduced (n=20) and normal bone density (n=20), determined using Q-CT. The tilting moments for each cup were determined five times in the group with reduced bone density and five times in the group with normal bone density, and the respective average values were calculated. The mean maximum extrusion force of the threaded cup Zintra was 5670.5 N (max. tilting moment 141.8 Nm) in bone with normal density and.5748.3 N (max. tilting moment 143.7 Nm) in osteoporotic bone. For the Hofer Imhof (HI) threaded cup it was 7681.5 N (192.0 Nm) in bone with normal density and 6828.9 N (max. tilting moment 170.7 Nm) in the group with osteoporotic bone. The mean maximum extrusion force of the macro-textured press-fit cup Metallsockel CL was 3824.6 N (max. tilting moment 95.6 Nm) in bone with normal and 2246.2 N (max. tilting moment 56.2 Nm) in osteoporotic bone. For the Monoblock it was 1303.8 N (max. tilting moment 32.6 Nm) in normal and 1317 N (max. tilting moment 32.9 Nm) in osteoporotic bone. There was no significance. A reduction of the maximum tilting moment in osteoporotic bone of the ESKA press-fit cup Metallsockel CL was noticed. Results on macerated bone specimens showed no statistically significant reduction of the maximum tilting moment in specimens with osteoporotic bone density compared to normal bone, neither for threaded nor for the press-fit cups. With the limitation that the results were obtained using macerated bone, we could not detect any restrictions for the clinical indication of the examined cementless cups in osteoporotic bone.

  14. Periprosthetic wear particle migration and distribution modelling and the implication for osteolysis in cementless total hip replacement.

    PubMed

    Alidousti, Hamidreza; Taylor, Mark; Bressloff, Neil W

    2014-04-01

    In total hip replacement (THR), wear particles play a significant role in osteolysis and have been observed in locations as remote as the tip of femoral stem. However, there is no clear understanding of the factors and mechanisms causing, or contributing to particle migration to the periprosthetic tissue. Interfacial gaps provide a route for particle laden joint fluid to transport wear particles to the periprosthetic tissue and cause osteolysis. It is likely that capsular pressure, gap dimensions and micromotion of the gap during cyclic loading of an implant, play defining roles to facilitate particle migration. In order to obtain a better understanding of the above mechanisms and factors, transient two-dimensional computational fluid dynamic simulations have been performed for the flow in the lateral side of a cementless stem-femur system including the joint capsule, a gap in communication with the capsule and the surrounding bone. A discrete phase model to describe particle motion has been employed. Key findings from these simulations include: (1) Particles were shown to enter the periprosthetic tissue along the entire length of the gap but with higher concentrations at both proximal and distal ends of the gap and a maximum rate of particle accumulation in the distal regions. (2) High capsular pressure, rather than gap micromotion, has been shown to be the main driving force for particle migration to periprosthetic tissue. (3) Implant micromotion was shown to pump out rather than draw in particles to the interfacial gaps. (4) Particle concentrations are consistent with known distributions of (i) focal osteolysis at the distal end of the gap and (ii) linear osteolysis along the entire gap length. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    PubMed

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  16. Risk factors for unsuccessful acetabular press-fit fixation at primary total hip arthroplasty.

    PubMed

    Brulc, U; Antolič, V; Mavčič, B

    2017-11-01

    Surgeon at primary total hip arthroplasty sometimes cannot achieve sufficient cementless acetabular press-fit fixation and must resort to other fixation methods. Despite a predominant use of cementless cups, this issue is not fully clarified, therefore we performed a large retrospective study to: (1) identify risk factors related to patient or implant or surgeon for unsuccessful intraoperative press-fit; (2) check for correlation between surgeons' volume of operated cases and the press-fit success rate. Unsuccessful intra-operative press-fit more often occurs in older female patients, particular implants, due to learning curve and low-volume surgeons. Retrospective observational cohort of prospectively collected intraoperative data (2009-2016) included all primary total hip arthroplasty patients with implant brands that offered acetabular press-fit fixation only. Press-fit was considered successful if acetabulum was of the same implant brand as the femoral component without additional screws or cement. Logistic regression models for unsuccessful acetabular press-fit included patients' gender/age/operated side, implant, surgeon, approach (posterior n=1206, direct-lateral n=871) and surgery date (i.e. learning curve). In 2077 patients (mean 65.5 years, 1093 females, 1163 right hips), three different implant brands (973 ABG-II™-Stryker, 646 EcoFit™ Implantcast, 458 Procotyl™ L-Wright) were implanted by eight surgeons. Their unsuccessful press-fit fixation rates ranged from 3.5% to 23.7%. Older age (odds ratio 1.01 [95% CI: 0.99-1.02]), female gender (2.87 [95% CI: 2.11-3.91]), right side (1.44 [95% CI: 1.08-1.92]), surgery date (0.90 [95% CI: 1.08-1.92]) and particular implants were significant risk factors only in three surgeons with less successful surgical technique (higher rates of unsuccessful press-fit with Procotyl™-L and EcoFit™ [P=0.01]). Direct-lateral hip approach had a lower rate of unsuccessful press-fit than posterior hip approach (P<0.01), but there was no correlation between surgeons' volume and rate of successful press-fit (Spearman's rho=0.10, P=0.82). Subcohort of 961 patients with 5-7-years follow-up indicated higher early/late cup revision rates with unsuccessful press-fit. Success of press-fit fixation depends entirely on the surgeon and surgical approach. With proper operative technique, the unsuccessful press-fit fixation rate should be below 5% and the impact of patients' characteristics or implants on press-fit fixation is then insignificant. Findings of huge variability in operative technique between surgeons of the presented study emphasize the need for surgeon-specific data stratification in arthroplasty studies and indicate the possibility of false attribution of clinically observed phenomena to patient-related factors in pooled data of large centers or hip arthroplasty registers. Level III, retrospective observational case control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Numeric simulation of bone remodelling patterns after implantation of a cementless straight stem.

    PubMed

    Lerch, Matthias; Windhagen, Henning; Stukenborg-Colsman, Christina M; Kurtz, Agnes; Behrens, Bernd A; Almohallami, Amer; Bouguecha, Anas

    2013-12-01

    For further development of better bone-preserving implants in total hip arthroplasty (THA), we need to look back and analyse established and clinically approved implants to find out what made them successful. Finite element analysis can help do this by simulating periprosthetic bone remodelling under different conditions. Our aim was thus to establish a numerical model of the cementless straight stem for which good long-term results have been obtained. We performed a numeric simulation of a cementless straight stem, which has been successfully used in its unaltered form since 1986/1987. We have 20 years of experience with this THA system and implanted it 555 times in 2012. We performed qualitative and quantitative validation using bone density data derived from a prospective dual-energy X-ray absorptiometry (DEXA) investigation. Bone mass loss converged to 9.25% for the entire femur. No change in bone density was calculated distal to the tip of the prosthesis. Bone mass decreased by 46.2% around the proximal half of the implant and by 7.6% in the diaphysis. The numeric model was in excellent agreement with DEXA data except for the calcar region, where deviation was 67.7%. The higher deviation in the calcar region is possibly a sign of the complex interactions between the titanium coating on the stem and the surrounding bone. We developed a validated numeric model to simulate bone remodelling for different stem-design modifications. We recommend that new THA implants undergo critical numeric simulation before clinical application.

  18. Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia.

    PubMed

    Nie, Yong; Wang, HaoYang; Huang, ZeYu; Shen, Bin; Kraus, Virginia Byers; Zhou, Zongke

    2018-01-01

    The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (P<.001). However, both methods yielded highly correlated measurements for cup coverage (Pearson r=0.761, P<.001). The size of the acetabular cup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone. [Orthopedics. 2018; 41(1):e46-e51.]. Copyright 2017, SLACK Incorporated.

  19. Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.

    PubMed

    Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D

    2015-04-01

    The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.

  20. Preclinical trial of a novel surface architecture for improved primary fixation of cementless orthopaedic implants.

    PubMed

    Harrison, Noel; Field, John R; Quondamatteo, Fabio; Curtin, William; McHugh, Peter E; Mc Donnell, Pat

    2014-09-01

    A new surface architecture for cementless orthopaedic implants (OsteoAnchor), which incorporates a multitude of tiny anchor features for enhancing primary fixation, was tested in an ovine hemi-arthroplasty pilot study. Test animals were implanted with a hip stem component incorporating the OsteoAnchor surface architecture produced using additive layer manufacturing and control animals were implanted with stems containing a standard plasma sprayed titanium coating. Intra-operative surgeon feedback indicated that superior primary fixation was achieved for the OsteoAnchor stems and rapid return to normal gait and load bearing was observed post-operation. Following a 16-week recovery time, histological evaluation of the excised femurs revealed in-growth of healthy bone into the porous structure of the OsteoAnchor stems. Bone in-growth was not achieved for the plasma sprayed stems. These results indicate the potential for the OsteoAnchor surface architecture to enhance both the initial stability and long term lifetime of cementless orthopaedic implants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. The Proximal and Distal Femoral Canal Geometry Influences Cementless Stem Anchorage and Revision Hip and Knee Implant Stability.

    PubMed

    Heinecke, Markus; Rathje, Fabian; Layher, Frank; Matziolis, Georg

    2018-05-01

    Although cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless press-fit stems of 4 different designs were implanted in synthetic femurs. The specimens were analyzed by computed tomography and were tested considering axial/torsional stiffness and migration resistance. Different stem designs anchored in different femoral canal geometries achieved comparable primary stability. Despite considerably different anchorage lengths, no difference in migration behavior or stiffness was found. Both in the distal femur and in the proximal femur, the conical stems showed a combination of conical and 3-point anchorage. Regarding the cylindrical stem tested, a much shorter anchorage length was sufficient in the distal femur to achieve comparable primary stability. In the investigated osseous defect model, the stem design (conical vs cylindrical), not the geometry of the femoral canal (proximal vs distal), was decisive regarding the circumferential anchorage length. For the conical stems, it can be postulated that there are reserves available for achieving a conical-circular fixation as a result of the large contact length. For the cylindrical stems, only a small reserve for a stable anchorage can be assumed. [Orthopedics. 2018; 41(3):e369-e375.]. Copyright 2018, SLACK Incorporated.

  2. Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years.

    PubMed

    Pritchett, James W

    2016-10-01

    Hip resurfacing is an option to consider when treating younger, more active patients. Advantages over total hip arthroplasty include a more normal gait and a lower incidence of thigh pain. In this prospective study, 190 hip resurfacing procedures (164 participants) were performed using a cobalt-chromium femoral component and a cementless acetabular cup with a 3.8-mm highly cross-linked polyethylene acetabular liner. The mean follow-up was 8.5 (range, 7-10) years. Two participants were lost to follow-up and 2 died. One participant underwent successful revision surgery for acetabular loosening. Four participants underwent successful revision to a total hip arthroplasty because of femoral neck fracture (2), femoral loosening, or infection. The Kaplan-Meier survivorship was 97%. Acetabular bone conservation was assessed using computed tomography by measuring the medial acetabular wall. The mean thickness was 9 mm. Femoral bone was well preserved with a mean head:neck ratio of 1.37. There were 4 (2%) osteolytic defects up to 0.9 cm(3) on computed tomography and no instances of impending polyethylene wear-through. Seven polyethylene retrievals had a measured wear rate of 0.05 mm/y. Hip resurfacing using a highly cross-linked polyethylene acetabular component is a reliable procedure. Both femoral and acetabular bones are reasonably preserved compared with prior resurfacing methods. The low incidence of osteolysis and the low rate of wear found on retrievals suggest that many years of use in highly active patients is possible. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. The Morscher Press-Fit Acetabular Component: An Independent Long-Term Review at 18-22 Years.

    PubMed

    Gwynne-Jones, David P; Lash, Heath W R; James, Andrew W; Iosua, Ella E; Matheson, John A

    2017-08-01

    There are relatively few 20-year results of uncemented acetabular components, and most of these are modular designs. This study reports the 20-year results of a monoblock press-fit acetabular component. A total of 122 total hip arthroplasties (111 patients) using the Morscher cup were reviewed at a mean of 19.7 years. The average age at implantation was 57.3 years (range, 36-74 years), and 81 (66%) were men. Twenty-two patients (25 hips) had died. Seven hips were revised, including 5 acetabular revisions. Six patients (6 hips) declined to participate but were known not to have been revised. The mean Oxford hip score was 41.1 (range, 22-48), and the mean reduced Western Ontario and McMaster Universities Osteoarthritis Index score was 5.7/48 (range, 0-24). Eccentric wear was seen in 13 (15.7%) and major osteolysis in 14 (17%) of 82 surviving hips with radiographs. The all-cause revision rate was 0.32 per 100 observed component years (95% confidence interval [CI], 0.13-0.66). The 20-year Kaplan-Meier survival was 93.4% (CI, 86.6-96.8) for all-cause revisions, 95.5% (CI, 89.4-98.1) for any acetabular revision, and 97.1% (CI, 91.2-99.1) for acetabular aseptic loosening, wear, or osteolysis. The Morscher acetabular component has continued to perform well at 20 years despite using conventional polyethylene with results that match or surpass other cementless acetabulae. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. To Cement or Not? Two-Year Results of a Prospective, Randomized Study Comparing Cemented Vs. Cementless Total Knee Arthroplasty (TKA).

    PubMed

    Fricka, Kevin B; Sritulanondha, Supatra; McAsey, Craig J

    2015-09-01

    The optimal mode of fixation in total knee arthroplasty (TKA) is a subject of debate. We enrolled 100 TKA patients randomized to cemented or cementless fixation. Knee Society Scores (KSS), Oxford scores and pain visual analog scales (VAS) were collected pre-operatively and post-operatively. Two-year follow-up was obtained for 93 patients. The mean VAS trended higher for the cementless group at 4 months (P=0.06). At 2 years, the KSS functional scores, Oxford scores, and self-reported questions for satisfaction, less pain and better function were similar but the cemented group had higher KSS clinical scores (96.4 vs. 92.3, P=0.03). More radiolucencies were seen in cementless knees (P<0.001). The cementless group had one revision for instability and one cemented knee was revised for infection. Cementless TKA showed equivalent survivorship (revision for any reason as the endpoint) compared to cemented TKA at this early follow-up. Close monitoring of radiolucencies is important with continued follow-up. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The influence of uncemented femoral stem length and design on its primary stability: a finite element analysis.

    PubMed

    Reimeringer, M; Nuño, N; Desmarais-Trépanier, C; Lavigne, M; Vendittoli, P A

    2013-01-01

    One of the crucial factors for short- and long-term clinical success of total hip arthroplasty cementless implants is primary stability. Indeed, motion at the bone-implant interface above 40 μm leads to partial bone ingrowth, while motion exceeding 150 μm completely inhibits bone ingrowth. The aim of this study was to investigate the effect of two cementless femoral stem designs with different lengths on the primary stability. A finite element model of a composite Sawbones(®) fourth generation, implanted with five lengths of the straight prosthesis design and four lengths of the curved prosthesis design, was loaded with hip joint and abductor forces representing two physiological activities: fast walking and stair climbing. We found that reducing the straight stem length from 146 to 54 mm increased the average micromotion from 17 to 52 μm during fast walking, while the peak value increased from 42 to 104 μm. With the curved stem, reducing length from 105 to 54 mm increased the average micromotion from 10 to 29 μm, while the peak value increased from 37 to 101 μm. Similar findings are obtained for stair climbing for both stems. Although the present study showed that femoral stem length as well as stem design directly influences its primary stability, for the two femoral stems tested, length could be reduced substantially without compromising the primary stability. With the aim of minimising surgical invasiveness, newer femoral stem design and currently well performing stems might be used with a reduced length without compromising primary stability and hence, long-term survivorship.

  6. Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.

    PubMed

    Weber, Markus; Woerner, Michael; Craiovan, Benjamin; Voellner, Florian; Worlicek, Michael; Springorum, Hans-Robert; Grifka, Joachim; Renkawitz, Tobias

    2016-12-01

    In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.

  7. Fabrication of low-cost, cementless femoral stem 316L stainless steel using investment casting technique.

    PubMed

    Baharuddin, Mohd Yusof; Salleh, Sh-Hussain; Suhasril, Andril Arafat; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Omar, Mohd Afian; Abd Kader, Ab Saman; Mohd Noor, Alias; A Harris, Arief Ruhullah; Abdul Majid, Norazman

    2014-07-01

    Total hip arthroplasty is a flourishing orthopedic surgery, generating billions of dollars of revenue. The cost associated with the fabrication of implants has been increasing year by year, and this phenomenon has burdened the patient with extra charges. Consequently, this study will focus on designing an accurate implant via implementing the reverse engineering of three-dimensional morphological study based on a particular population. By using finite element analysis, this study will assist to predict the outcome and could become a useful tool for preclinical testing of newly designed implants. A prototype is then fabricated using 316L stainless steel by applying investment casting techniques that reduce manufacturing cost without jeopardizing implant quality. The finite element analysis showed that the maximum von Mises stress was 66.88 MPa proximally with a safety factor of 2.39 against endosteal fracture, and micromotion was 4.73 μm, which promotes osseointegration. This method offers a fabrication process of cementless femoral stems with lower cost, subsequently helping patients, particularly those from nondeveloped countries. Copyright © 2013 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Preoperative digital planning versus postoperative outcomes in total hip arthroplasty using a calcar-guided short stem: frequent valgization can be avoided.

    PubMed

    Kutzner, Karl Philipp; Pfeil, Joachim; Kovacevic, Mark Predrag

    2017-07-01

    Modern total hip arthroplasty is largely dependent on the successful preservation of hip geometry. Thus, a successful implementation of the preoperative planning is of great importance. The present study evaluates the accuracy of anatomic hip reconstruction predicted by 2D digital planning using a calcar-guided short stem of the newest generation. A calcar-guided short stem was implanted in 109 patients in combination with a cementless cup using the modified anterolateral approach. Preoperative digital planning was performed including implant size, caput-collum-diaphyseal angle, offset, and leg length using mediCAD II software. A coordinate system and individual scale factors were implemented. Postoperative outcome was evaluated accordingly and was compared to the planning. Intraoperatively used stem sizes were within one unit of the planned stem sizes. The postoperative stem alignment showed a minor and insignificant (p = 0.159) mean valgization of 0.5° (SD 3.79°) compared to the planned caput-collum-diaphyseal angles. Compared to the planning, mean femoral offset gained 2.18 (SD 4.24) mm, while acetabular offset was reduced by 0.78 (SD 4.36) mm during implantation resulting in an increased global offset of 1.40 (SD 5.51) mm (p = 0.0094). Postoperative femoroacetabular height increased by a mean of 5.00 (SD 5.98) mm (p < 0.0001) compared to preoperative measures. Two-dimensional digital preoperative planning in calcar-guided short-stem total hip arthroplasty assures a satisfying implementation of the intended anatomy. Valgization, which has been frequently observed in previous short-stem designs, negatively affecting offset, can be avoided. However, surgeons have to be aware of a possible leg lengthening.

  9. Primary stability of a cementless acetabular cup in a cohort of patient-specific finite element models.

    PubMed

    O'Rourke, Dermot; Al-Dirini, Rami Ma; Taylor, Mark

    2018-03-01

    The primary stability achieved during total hip arthroplasty determines the long-term success of cementless acetabular cups. Pre-clinical finite element testing of cups typically use a model of a single patient and assume the results can be extrapolated to the general population. This study explored the variability in predicted primary stability of a Pinnacle ® cementless acetabular cup in 103 patient-specific finite element models of the hemipelvis and examined the association between patient-related factors and the observed variability. Cups were inserted by displacement-control into the FE models and then a loading configuration simulating a complete level gait cycle was applied. The cohort showed a range of polar gap of 284-1112 μm and 95th percentile composite peak micromotion (CPM) of 18-624 μm. Regression analysis was not conclusive on the relationship between patient-related factors and primary stability. No relationship was found between polar gap and micromotion. However, when the patient-related factors were categorised into quartile groups, trends suggested higher polar gaps occurred in subjects with small and shallow acetabular geometries and cup motion during gait was affected most by low elastic modulus and high bodyweight. The variation in primary stability in the cohort for an acetabular cup with a proven clinical track record may provide benchmark data when evaluating new cup designs. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1012-1023, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Tapered stems one-third proximally coated have higher complication rates than cylindrical two-third coated stems in patients with high hip dislocation undergoing total hip arthroplasty with step-cut shortening osteotomy.

    PubMed

    Ozden, V Emre; Dikmen, G; Beksac, B; Tozun, I Remzi

    2017-06-01

    The results of cementless stems in total hip arthroplasty (THA) done because of congenital dislocation with step-cut osteotomy is not well known, particularly the influence of the design and the role of extent of porous coating. Therefore we performed a retrospective study to evaluate the mid to long-term results THA performed with a single type acetabular component and different geometry and fixation type stems with ceramic bearings in the setting of step-cut subtrochanteric osteotomy in high hip dislocated (HHD) patients. We asked if the stem type affect the outcomes in terms of (1) intra and postoperative complication rates (2) radiographic outcomes (3) prosthesis survival in step-cut subtrochanteric shortening osteotomy. The type of the stem, whether cylindrical or tapered does not affect the outcome if the femoral canal fit and fill is obtained and the step-cut femoral shortening osteotomy is primarily fixed. Forty-five hips in 35 patients with a mean follow up of 10 years (range, 7-14 years) were evaluated. The single type cementless cup was placed at the level of the true acetabulum, a step-cut shortening femoral osteotomy was performed and reconstruction was performed with two different types of tapered stem in twenty-two hips (Synergy™ and Image™ proximally coated, Smith and Nephew, Menphis, TN, USA) and one type of cylindrical stem (Echelon™ with 2/3 coated, Smith and Nephew, Menphis, TN, USA) in twenty-three hips. Harris hip scores (HHS) and a University of California Los Angeles (UCLA) activity scores were calculated for all patients and successive X-rays were evaluated regarding component loosening and osteolysis, along with complications related to bearing, step-cut osteotomy and stem types. Forty-one hips (91%) had good and excellent clinical outcome according to HHS. The mean UCLA activity scores improved from 3.2±0.6 points (range, 2-4) preoperatively to 6.3 points±0.5 (range, 5-7) at the latest follow-up. The mean femoral shortening was 36±10mm (range, 20-65mm). Four (9%) dislocations were observed. There were five (11%) intra-operative femoral fractures and three (7%) cases of non-union, which were observed in tapered stems. Cylindrical stems had superior neutral alignment primarily. With any stem revision as the end point, cylindrical stems had a higher survival rate (100%) than all tapered stems (82%; 95% confident interval [CI] 77-97%) at ten years. With any revision as the end point, the 10-year survival rate for acetabular component (Reflection-Ceramic Interfit) and for femoral components were 98% (95% CI, 85-99%) and 91% (95% CI, 78-97%), respectively. There were more implant related complications in HHD patients undergoing THA when tapered stems with 1/3 proximal coating were used to reconstruct a step cut osteotomized femur, compared to cylindrical stems 2/3 coated. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. Influence of functionally graded pores on bone ingrowth in cementless hip prosthesis: a finite element study using mechano-regulatory algorithm.

    PubMed

    Tarlochan, Faris; Mehboob, Hassan; Mehboob, Ali; Chang, Seung-Hwan

    2018-06-01

    Cementless hip prostheses with porous outer coating are commonly used to repair the proximally damaged femurs. It has been demonstrated that stability of prosthesis is also highly dependent on the bone ingrowth into the porous texture. Bone ingrowth is influenced by the mechanical environment produced in the callus. In this study, bone ingrowth into the porous structure was predicted by using a mechano-regulatory model. Homogenously distributed pores (200 and 800 [Formula: see text]m in diameter) and functionally graded pores along the length of the prosthesis were introduced as a porous coating. Bone ingrowth was simulated using 25 and 12 [Formula: see text]m micromovements. Load control simulations were carried out instead of traditionally used displacement control. Spatial and temporal distributions of tissues were predicted in all cases. Functionally graded pore decreasing models gave the most homogenous bone distribution, the highest bone ingrowth (98%) with highest average Young's modulus of all tissue phenotypes approximately 4.1 GPa. Besides this, the volume of the initial callus increased to 8.33% in functionally graded pores as compared to the 200 [Formula: see text]m pore size models which increased the bone volume. These findings indicate that functionally graded porous surface promote bone ingrowth efficiently which can be considered to design of surface texture of hip prosthesis.

  12. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.

    PubMed

    Varnum, Claus

    2017-03-01

    Total hip arthroplasty (THA) is a common and successful treatment of patients suffering from severe osteoarthritis that significantly reduces pain and improves hip function and quality of life. Traditionally, the outcome of THA has been evaluated by orthopaedic surgeons and assessed in morbidity and mortality rates, and implant survival. As patients and surgeons may assess outcome after THA differently, patient-reported outcomes (PROMs) have gained much more interest and are today recognized as very important tools for evaluating the outcome and satisfaction after THA. One of the prognostic factors for the outcome of THA is the type of bearings. This PhD thesis focuses on the influence of different types of bearings on implant survival, revision causes, PROMs, and noises from THA. The aims of the thesis were: Study I: To examine the revision risk and to investigate the causes of revision of cementless ceramic-on-ceramic (CoC) THAs comparing them to those of "standard" metal-on-polyethylene (MoP) THAs. Study II: To compare the six-year revision risk for metal-on-metal (MoM) with that for MoP bearings in cementless stemmed THA, and further to study the revision risk for different designs of stemmed MoM THAs and the causes of revision. Study III: To examine the association between CoC, MoM, and MoP bearings and both generic and disease-specific PROMs, and furthermore to examine the incidence and types of noises from the three types of bearings and identify the effect of noises on PROM scores. In study I and III, we used data from the Danish Hip Arthroplasty Registry combined with data from the Civil Registration System and the Danish National Patient Registry. In study II, data from the Nordic Arthroplasty Register Association, containing data from hip arthroplasty registries in Denmark, Norway, Sweden, and Finland, was used. In study I, 11,096 patients operated from 2002 through 2009 with cementless THA were included. Of these, 16% had CoC THA and 84% had MoP THA. At 8.7-year follow-up, no difference in RR of revision for any cause was found for CoC compared to MoP THA. One cause of revision related only to CoC THA is ceramic fracture. Medical records were reviewed for patients who had revision surgery due to component failure, and six patients (0,34%) had been revised due to ceramic fracture. No other difference in prevalence of causes of revision was found when comparing CoC to MoP THA. Study II included 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). At six-year follow-up, the RR of revision for any cause was significantly higher for MoM compared to MoP THA. When comparing different combinations of cup/stem with MoM to MoP bearings, there was an increased RR of revision for any cause for the ASR/Summit, ASR/Corail, and "other" combinations. There was a higher prevalence of revision due to aseptic loosening for MoM compared to MoP THA. In contrast, the prevalence of revision due to dislocation was lower for MoM THA. In study III, a set of questionnaires including HOOS, EQ-5D, UCLA activity score, and a questionnaire about noises from the THA was sendt to patients having THA with CoC, MoM, or MoP bearings. The response rate was 85% and among the 3,089 patients responding, 45% received CoC, 17% MoM, and 38% MoP THA. No differences in mean subscale scores were found for CoC and MoM compared to MoP THA, except for CoC THA that had a lower mean HOOS symptoms score than MoP THA. 27% of patients with CoC, 29% of patients with MoM, and 12% of patients with MoP bearings had experienced noises from the THA. For the three types of bearings, PROM scores from patients with noisy THA were significantly lower when compared to silent MoP THA, except for noisy CoC and MoM THA that had the same mean UCLA activity score as silent MoP THA.

  13. Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty.

    PubMed

    Dorr, L D; Bloebaum, R; Emmanual, J; Meldrum, R

    1990-12-01

    Large amounts of metal and polyethylene debris and high ion readings are found in capsule and fibrous membranes of both loose titanium and cobalt-chromium stems. Prostaglandin E2, interleukin-1, and collagenase levels are elevated when compared to control values with collagenase having the highest and most consistent elevations. Synovial fluid and blood ion readings were elevated in loose cemented and cementless stems made from both materials. Blood ion readings were not elevated in fixed stems. Fixed stems had much less particulate debris in soft tissues. The data showed that failure of most metal hip stems was initially due to a mechanical cause, with high debris and ion counts occurring secondarily in capsule and fibrous membranes. Particulate debris and high ion readings are primarily a focal problem contained by the periprosthetic fibrous connective-tissue encapsulation within the femoral canal and joint capsules. No systemic problems were manifest in any of the patients examined and followed in this study.

  14. Could larger diameter of 4th generation ceramic bearing decrease the rate of dislocation after THA?

    PubMed

    Lee, Young-Kyun; Ha, Yong-Chan; Jo, Woo-Lam; Kim, Tae-Young; Jung, Woon-Hwa; Koo, Kyung-Hoi

    2016-05-01

    Fourth generation (Delta) ceramic bearing was developed to reduce dislocation after total hip arthroplasty (THA) by increasing the head diameter. We tested a hypothesis that 32/36 mm Delta ceramic bearing decreases the dislocation rate. We also evaluated ceramic-related complications and early outcome of this thin liner-on-large head ceramic bearing. We performed a prospective study on patients who underwent THA with use of 32/36 mm Delta ceramic bearing. The dislocation rate was compared with the historical dislocation rate of third generation 28 mm ceramic bearing. We also evaluated ceramic fracture, squeak, short-term results and survival. Follow-up period was minimum 2 years. Between April 2010 and February 2012, we enrolled 250 consecutive patients (278 hips). All patients received cementless prostheses. Four patients (4 hips) who received metal shells ≤ 46 mm and 28 mm heads were excluded. Three patients died and 2 patients were lost within 2 years. The remaining 241 patients (269 hips) were followed for 24-46 months. There were 142 men (161 hips) and 99 women (108 hips) with a mean age of 53.7 years (range, 17-75 years) at the index operation. Dislocation occurred in three hips (1.1%). An old age was a risk factor for dislocation. Ceramic fracture and squeaking did not occur in any patient. Mean Harris hip score was 90.3 points at the latest follow-up. All acetabular and femoral components had bone-ingrowth stability. No hip had detectable wear or osteolysis. The survival was 99.3% in the best case scenario and 97.8% in the worst at 48 months. Total hip arthroplasty with use of 32/36 mm Delta ceramic bearing showed lower incidence of hip dislocation compared with 28 mm third generation ceramic bearing. A caution should be paid to prevent a fall in senile patients even though a large head is used. The short-term results of THA with this type of ceramic articulation are encouraging and we did not find any ceramic-related complications. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  15. Initial stability of cementless acetabular cups: press-fit and screw fixation interaction--an in vitro biomechanical study.

    PubMed

    Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi

    2015-04-01

    Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.

  16. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers.

    PubMed

    Malfroy Camine, V; Rüdiger, H A; Pioletti, D P; Terrier, A

    2016-12-08

    A good primary stability of cementless femoral stems is essential for the long-term success of total hip arthroplasty. Experimental measurement of implant micromotion with linear variable differential transformers is commonly used to assess implant primary stability in pre-clinical testing. But these measurements are often limited to a few distinct points at the interface. New techniques based on micro-computed tomography (micro-CT) have recently been introduced, such as Digital Volume Correlation (DVC) or markers-based approaches. DVC is however limited to measurement around non-metallic implants due to metal-induced imaging artifacts, and markers-based techniques are confined to a small portion of the implant. In this paper, we present a technique based on micro-CT imaging and radiopaque markers to provide the first full-field micromotion measurement at the entire bone-implant interface of a cementless femoral stem implanted in a cadaveric femur. Micromotion was measured during compression and torsion. Over 300 simultaneous measurement points were obtained. Micromotion amplitude ranged from 0 to 24µm in compression and from 0 to 49µm in torsion. Peak micromotion was distal in compression and proximal in torsion. The technique bias was 5.1µm and its repeatability standard deviation was 4µm. The method was thus highly reliable and compared well with results obtained with linear variable differential transformers (LVDTs) reported in the literature. These results indicate that this micro-CT based technique is perfectly relevant to observe local variations in primary stability around metallic implants. Possible applications include pre-clinical testing of implants and validation of patient-specific models for pre-operative planning. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Statistical analysis of interfacial gap in a cementless stem FE model.

    PubMed

    Park, Youngbae; Choi, Donok; Hwang, Deuk Soo; Yoon, Yong-San

    2009-02-01

    In cementless total hip arthroplasty, a fair amount of interfacial gap exists between the femoral stem and the bone. However, the effect of these gaps on the mechanical stability of the stem is poorly understood. In this paper, a finite element model with various interfacial gap definitions is used to quantify the effect of interfacial gaps on the primary stability of a Versys Fiber Metal Taper stem under stair climbing loads. In the first part, 500 random interfacial gap definitions were simulated. The resulting micromotion was approximately inversely proportional to the contact ratio, and the variance of the micromotion was greater with a lower contact ratio. Moreover, when the magnitude of the micromotion was compared between the gap definitions that had contact at a specific site and those that had no contact at that site, it was found that gaps located in the proximal-medial region of the stem surface had the most important effect on the micromotion. In a second trial, 17 gap definitions mimicking a gap pattern that has been observed experimentally were simulated. For a given contact ratio, the micromotion observed in the second trial was lower than the average result of those in the first, where the gaps were placed randomly. In either trial, when the contact ratio was higher than 40%, the micromotion showed no significant difference (first trial) or a gentle slope (-0.24 mum% in the second trial) in relation to the contact ratio. Considering the reported contact ratios for properly implanted stems, variations in the amount of interfacial gap would not likely cause a drastic difference in micromotion, and this effect could be easily overshadowed by other clinical factors. In conclusion, differences in interfacial gaps are not expected to have a noticeable effect on the clinical micromotion of this cementless stem.

  18. Preparation of the femoral bone cavity in cementless stems: broaching versus compaction

    PubMed Central

    Hjorth, Mette H; Stilling, Maiken; Søballe, Kjeld; Nielsen, Poul Torben; Christensen, Poul H; Kold, Søren

    2016-01-01

    Background and purpose — Short-term experimental studies have confirmed that there is superior fixation of cementless implants inserted with compaction compared to broaching of the cancellous bone. Patients and methods — 1-stage, bilateral primary THA was performed in 28 patients between May 2001 and September 2007. The patients were randomized to femoral bone preparation with broaching on 1 side and compaction on the other side. 8 patients declined to attend the postoperative follow-up, leaving 20 patients (13 male) with a mean age of 58 (36–70) years for evaluation. The patients were followed with radiostereometric analysis (RSA) at baseline, at 6 and 12 weeks, and at 1, 2, and 5 years, and measurements of periprosthetic bone mineral density (BMD) at baseline and at 1, 2, and 5 years. The subjective part of the Harris hip score (HHS) and details of complications throughout the observation period were obtained at a mean interval of 6.3 (3.0–9.5) years after surgery. Results — Femoral stems in the compaction group had a higher degree of medio-lateral migration (0.21 mm, 95% CI: 0.03–0.40) than femoral stems in the broaching group at 5 years (p = 0.02). No other significant differences in translations or rotations were found between the 2 surgical techniques at 2 years (p > 0.4) and 5 years (p > 0.7) postoperatively. There were no individual stems with continuous migration. Periprosthetic BMD in the 7 Gruen zones was similar at 2 years and at 5 years. Intraoperative femoral fractures occurred in 2 of 20 compacted hips, but there were none in the 20 broached hips. The HHS and dislocations were similar in the 2 groups at 6.3 (3.0–9.5) years after surgery. Interpretation — Bone compaction as a surgical technique with the Bi-Metric stem did not show the superior outcomes expected compared to conventional broaching. Furthermore, 2 periprosthetic fractures occurred using the compaction technique, so we cannot recommend compaction for insertion of the cementless Bi-Metric stem. PMID:27759486

  19. Influence of undersized cementless hip stems on primary stability and strain distribution.

    PubMed

    Fottner, Andreas; Woiczinski, Matthias; Kistler, Manuel; Schröder, Christian; Schmidutz, Tobias F; Jansson, Volkmar; Schmidutz, Florian

    2017-10-01

    Undersizing of cementless hip stems is a risk factor for aseptic loosening and early subsidence. The purpose of this study was to evaluate the effects of undersized stems and determine whether a biomechanical study can predict the clinical results. Three consecutive sizes of a clinically proven stem (CLS Spotorno) were implanted into six composite femora (size large, Sawbones ® ), respectively. According to the Canal Fill Index (CFI), two stems (size 11.25 and 12.5) were undersized (CFI < 80%) and one stem (size 13.75) had an appropriate size (CFI > 80%). The primary stability was evaluated by measurement of 3-dimensional (3D)-micromotions under physiological adapted load and surface strains were recorded before and after implantation to detect stress-shielding processes. Both undersized stems revealed significantly higher micromotions in all regions compared to the appropriate stem. The highest micromotions were registered at the distal tip of the three stem sizes. The changes in surface strain did not show a significant difference between the three stem sizes, but the highest strain reduction was observed proximally indicating a tendency for stress shielding. This study confirms the clinical assumption that undersized stem result in a significantly reduced primary stability. Furthermore, in vitro studies allow to determine the effects of undersizing and stress shielding processes.

  20. [A therapeutic effect analysis of femur first principle and combined anteversion technique during total hip arthroplasty].

    PubMed

    Wang, X Q; Wu, C S; Sun, S; Wang, J; Li, W; Zhang, W

    2018-04-01

    Objective: To investigate the situation of hip dislocation with the application of "femur first" principle and "combined anteversion technique" during total hip arthroplasty. Methods: A retrospective analysis has been done on the clinical data about 104 patients(133 hips)who were diagnosed as hip disease and were treated with total hip arthroplasty by the doctors from the Department of Joint Orthorpaedics of Shandong Provincial Hospital Affiliated to Shandong University from June 2014 to June 2016, and all the prostheses applied in the operation were cementless ones.Among them, 65 patients were males, 39 females and their age was 46.6 years (ranging from 23 to 76 years) .And 29 of them underwent bilateral hip operations and 75 unilateral ones.Seventy-six cases of aseptic necrosis of the femoral head in the terminal stage, 28 cases of hip dysplasia and osteoarthritis.Surgical approach: of all the operations, 103 hips were operated on with hardinge approach, 30 with posterolateral approach.During the operation, first of all, the femoral medullary cavity was broached and then the anteversion of intramedullary broacher was measured.After that, the anteversion of the acetabular cup was calculated as 37° minus the anteversion of the broacher, and the acetabular cup was implanted at that angle.The patients' prosthesis combined anteversion, range of motion of the hip joint, operation time, hemorrhage amount, and complications had been kept record.One, three, and six months respectively after the operation, all the patients received outpatient review, and took anteroposterior and lateral position X-ray examination.Harris hip score had been applied to evaluate their hip function before the operation and six months after the operation. Results: All the patients had been operated on smoothly, with the operation time of(57.6±14.5)minutes(36-115 minutes)and hemorrhage amount of (336.5±50.8)ml(180-620 ml). The operation finding showed that the combined anteversion by employing"femur first"principle and combined anteversion techniqueis was (36.6±6.8)°. Also, range of motion of the patients' hip conforms to the D'Lima criterion and no patients had experienced dislocation and some other serious complications.The follow-up ended at August 2017, which lasted for 12.2 months(6-18 months), and 88 cases(119 hips) were interviewed. The Harris hip score for the affected sides of the hip joints 6 months after the surgery was 94.6(86-100). Compared with the score of 29.8(12-43) before surgery, the t -test had proven its statistical significance( t =12.82, P =0.003). Conclusion: Based upon the "femoral first" principle and "combined anteversion technique" during total hip arthroplasty, these operations has been carried out well enough to meet the patients' needs of performing normal daily activities.

  1. [Effect of bone cement application on the incidence of deep vein thrombosis in major joint arthroplasties].

    PubMed

    Aslan, Ahmet; Ağar, Emre; Aydoğan, Nevres Hürriyet; Atay, Tolga; Baydar, Metin Lütfi; Kırdemir, Vecihi; Ozden, Ahmet

    2011-12-01

    In this study, we have investigated whether the application of bone cement has an effect on the frequency of deep vein thrombosis (DVT) in major joint arthroplasties (MJA). A total of 95 MJA cases meeting the inclusion criteria of this study between January 2004 and January 2005 were divided into cemented and cementless groups. For prophylaxis, all patients were given low molecular weight heparin (LMWH). The patients were scanned for DVT preoperatively and on the postoperative 12(th) day by color Doppler ultrasonography. In hip arthroplasties, in knee arthroplasties and in general, DVT was seen more frequently in cemented group, however, there was no statistically significant difference between groups in the frequency of DVT (p=0.549, p=0.749 and p=0.462, respectively). Also, there was no significant difference between the results of the different LMWH groups (p=0.616). The results of this study shows that bone cement application in MJAs such as hip or knee arthroplasties has no significant effect on the frequency of DVT.

  2. Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty

    PubMed Central

    Havranek, Vitezslav; Zapletalova, Jana

    2009-01-01

    We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression analysis. Factors associated with an increased/decreased wear rate included position of the cup relative to Kohler’s line, increase in abduction angle of the cup, traumatic and inflammatory arthritis as a primary diagnosis, and patient height. Severe acetabular bone defects were predicted by an increased wear rate (odds ratio, OR = 5.782 for wear rate above 200 mm3/y), and increased height of the patient (OR = 0.905 per each centimetre). Predictors of severe bone defects in the femur were the increased wear rate (OR = 3.479 for wear rate above 200 mm3/y) and placement of the cup outside of the true acetabulum (OR = 3.292). Variables related to surgical technique were the most predictive of polyethylene wear rate. PMID:19214506

  3. Comparison of synovial fluid, urine, and serum ion levels in metal-on-metal total hip arthroplasty at a minimum follow-up of 18 years.

    PubMed

    Lass, Richard; Grübl, Alexander; Kolb, Alexander; Stelzeneder, David; Pilger, Alexander; Kubista, Bernd; Giurea, Alexander; Windhager, Reinhard

    2014-09-01

    Diagnosis of adverse reactions to metal debris in metal-on-metal hip arthroplasty is a multifactorial process. Systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urine, or synovial fluid levels and adverse local tissue reactions is still incompletely understood. The hypothesis was that elevated serum and urine metal-ion concentrations are associated with elevated local metal-ion concentrations in primary total hip arthroplasties (THA) and with failure of metal-on-metal articulations in the long-term. In our present study, we evaluated these concentrations in 105 cementless THA with metal-on-metal articulating surfaces with small head diameter at a minimum of 18 years postoperatively. Spearman correlation showed a high correlation between the joint fluid aspirate concentration of cobalt and chromium with the serum cobalt (r = 0.81) and chromium level (r = 0.77) in patients with the THA as the only source of metal-ions. In these patients serum metal-ion analysis is a valuable method for screening. In patients with more than one source of metal or renal insufficiency additional investigations, like joint aspirations are an important tool for evaluation of wear and adverse tissue reactions in metal-on-metal THA. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Minimum ten-year results of primary bipolar hip arthroplasty for degenerative arthritis of the hip.

    PubMed

    Pellegrini, Vincent D; Heiges, Bradley A; Bixler, Brian; Lehman, Erik B; Davis, Charles M

    2006-08-01

    Bipolar hip arthroplasty has been advocated by some as an alternative to total hip arthroplasty for the treatment of degenerative arthritis of the hip. We sought to assess the results of this procedure at our institution after a minimum duration of follow-up of ten years. We retrospectively reviewed a consecutive series of 152 patients (173 hips) who underwent primary bipolar hemiarthroplasty for the treatment of symptomatic degenerative arthritis of the hip with a cementless femoral component between 1983 and 1987. Of the original cohort of 152 patients, ninety-two patients (104 hips) were available for clinical and radiographic review at a mean of 12.2 years postoperatively. At the time of the latest follow-up, self-administered Harris hip questionnaires were used to assess pain, mobility, activity level, and overall satisfaction with the procedure. Biplanar hip radiographs were made to evaluate bipolar shell migration, osteolysis, and femoral stem fixation. At the time of the latest follow-up, nineteen patients (nineteen hips) had undergone revision to total hip arthroplasty because of mechanical failure, and three patients (three hips) were awaiting revision because of symptomatic radiographic mechanical failure. Twelve acetabular revisions were performed or scheduled for the treatment of pelvic osteolysis or protrusio acetabuli secondary to component migration. Acetabular reconstruction required bone-grafting, an oversized shell, and/or a pelvic reconstruction ring. The overall rate of mechanical failure was 21.2% (twenty-two of 104 hips), with 91% (twenty) of the twenty-two failures involving the acetabular component. Reaming of the acetabulum at the time of the index arthroplasty was associated with a 6.4-fold greater risk of revision. The rate of implant survival, with revision because of mechanical failure as the end point, was 94.2% for femoral components and 80.8% for acetabular components at a mean of 12.2 years. Of the remaining sixty-nine patients (eighty-one hips) in whom the original prosthesis was retained, seventeen patients (24.6%) rated the pain as moderate to severe. Nearly 30% of patients with an intact prosthesis required analgesics on a regular basis. Radiographs were available for fifty-eight hips (including all of the hips with moderate to severe pain) after a minimum duration of follow-up of ten years; twenty-eight of these fifty-eight hips had radiographic evidence of acetabular component migration. This bipolar cup, when used for hemiarthroplasty in patients with symptomatic arthritis of the hip, was associated with unacceptably high rates of pain, migration, osteolysis, and the need for revision to total hip arthroplasty, especially when the acetabulum had been reamed. To the extent that these findings can be generalized to similar implant designs with conventional polyethylene, we do not recommend bipolar hemiarthroplasty as the primary operative treatment for degenerative arthritis of the hip.

  5. Intra-operative evaluation of cementless hip implant stability: a prototype device based on vibration analysis.

    PubMed

    Lannocca, Maurizio; Varini, Elena; Cappello, Angelo; Cristofolini, Luca; Bialoblocka, Ewa

    2007-10-01

    Cementless implants are mechanically stabilized during surgery by a press-fitting procedure. Good initial stability is crucial to avoid stem loosening and bone cracking, therefore, the surgeon must achieve optimal press-fitting. A possible approach to solve this problem and assist the surgeon in achieving the optimal compromise, involves the use of vibration analysis. The present study aimed to design and test a prototype device able to evaluate the primary mechanical stability of a cementless prosthesis, based on vibration analysis. In particular, the goal was to discriminate between stable and quasi-stable implants; thus the stem-bone system was assumed to be linear in both cases. For that reason, it was decided to study the frequency responses of the system, instead of the harmonic distortion. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The most sensitive parameter to stability was the shift in resonance frequency of the stem-bone system, which was highly correlated with residual micromotion on all four specimens.

  6. Preoperative Joint Space Width Predicts Patient-Reported Outcomes After Total Hip Arthroplasty in Young Patients.

    PubMed

    Stambough, Jeffrey B; Xiong, Ao; Baca, Geneva R; Wu, Ningying; Callaghan, John J; Clohisy, John C

    2016-02-01

    In a new health care economy, there is an emerging need to understand and quantify predictors of total hip arthroplasty (THA) outcomes. We investigated the association between preoperative radiographic disease (as measured quantitatively by joint space width [JSW]) and patient-reported function, activity, pain, and quality of life after THA. We retrospectively analyzed 146 patients (146 hips) 55 years or younger with a diagnosis of osteoarthritis who underwent cementless THA between January 2009 and December 2010. Preoperative pelvic radiographs were measured by 1 author blinded to clinical outcomes to establish JSW, defined as the shortest distance between the femoral head margin and the superolateral weight-bearing portion of the acetabulum. The JSW value was treated as a continuous variable when applied to statistical modeling. The relationship between the JSW and the improvement of clinical outcome was examined via a general linear modeling approach with adjustments for patients' age, body mass index, and sex. We identified an inverse relationship between preoperative JSW and improvements in functional, activity, pain, and quality of life. We found that, as JSW decreased by 1 mm, the outcome measure improvements were modified Harris Hip Score of 6.3 (p<0.001); SF-12 physical: 2.1 (p=0.027); WOMAC-pain: 4.8 (p=0.01); and UCLA Activity: 0.44 (p=0.02). Our results demonstrate that patients with greater preoperative joint space have less predictable improvement in terms of function, pain relief, and activity. These findings suggest that THA in young patients with a JSW less than 1.5 to 2 mm provides more predictable improvements in pain and functional outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell.

    PubMed

    Delanois, Ronald E; Gwam, Chukwuweike U; Mohamed, Nequesha; Khlopas, Anton; Chughtai, Morad; Malkani, Arthur L; Mont, Michael A

    2017-09-01

    We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes. Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits. The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up. At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Bending stiffness, torsional stability, and insertion force of cementless femoral stems.

    PubMed

    Incavo, S J; Johnson, C C; Churchill, D L; Beynnon, B D

    2001-04-01

    In cementless total hip arthroplasty, increased femoral stem flexibility and decreased fracture propensity are desirable characteristics. The slotting and tapering of the stem have been introduced to achieve this. These features should not, however, be allowed to interfere with the ability of the distal stem to provide initial mechanical stability, especially under rotation. This study was done to investigate the ability of slotted and tapered stem designs to reduce stiffness and insertion force while still maintaining adequate torsional strength. The torsional strength, maximum insertion force, and insertional work of straight, slotted, and taper stems were measured by inserting each type into rigid polyurethane foam and torque testing to failure. Bending stiffness of each stem design was calculated using numerical methods. When compared to a straight stem, a unislot stem has similar torsional strength, maximum insertional force, and work of insertion. The bending stiffness is decreased by 19% to 82% depending on the bending direction. A trislot design decreased torque strength by 29%, maximal insertion force by 36%, and work by 11%. Bending stiffness was decreased by 74% and was not dependent on bending direction. A 0.5-mm taper decreased torque strength by 11% and insertional work by 14%. No difference was seen in maximum insertional force. We conclude that the design features studied (slots and taper) are effective in decreasing stem stiffness and reducing fracture propensity.

  9. Bone remodelling after femoral short stem implantation in total hip arthroplasty: 1-year results from a randomized DEXA study.

    PubMed

    Freitag, Tobias; Hein, Marie-Anne; Wernerus, Dirk; Reichel, Heiko; Bieger, Ralf

    2016-01-01

    Short stem prostheses have been developed to preserve proximal femoral bone stock. This prospective, randomized study compared periprosthetic bone remodelling following short and straight stem implantation 1 year after surgery. One hundred and forty-four consecutive patients undergoing total hip arthroplasty were randomized to either a Fitmore short or a cementless straight stem (both Zimmer, Winterthur, Switzerland). Periprosthetic bone mineral density (BMD) was measured using dual-energy X-ray absorptiometry performed the day before surgery and at 7 days, 3 months and 1 year postoperatively. Furthermore, the HHS and the WOMAC were obtained. One hundred and thirty-eight patients completed 1-year follow-up. Periprosthetic BMD changes at 1 year were most pronounced in the proximal medial region of interest (ROI) 7 with -17.2% after short stem and -16.7% after straight implantation (p = 0.67). However, there was significantly less BMD reduction in ROI 6 following short (-4.7%) versus straight stem (-10.8%) implantation (p = 0.01). There were no significant differences between the two groups in terms of the HHS and the WOMAC either before or after surgery. One year after surgery, both stems showed an implant-specific periprosthetic bone remodelling. Nevertheless, proximal load transfer was more pronounced after short stem implantation than with a straight stem.

  10. Effectiveness of autologous fibrin tissue adhesive in reducing postoperative blood loss during total hip arthroplasty: a prospective randomised study of 100 cases.

    PubMed

    Mawatari, M; Higo, T; Tsutsumi, Y; Shigematsu, M; Hotokebuchi, T

    2006-08-01

    To evaluate the effectiveness of autologous fibrin tissue adhesive (auto-FTA) in reducing blood loss during cementless total hip arthroplasty (THA). From September 2000 to August 2001, 100 patients who predonated 400 ml of autologous blood were randomised to undergo either standard treatment with auto-FTA (auto-FTA group) or standard treatment alone (control group). The volume of postoperative blood loss and the decrease in haemoglobin level were measured. All patients were followed up for 3 years to evaluate the rate of bone ingrowth and heterotopic ossification. The mean postoperative blood loss was 580 ml (standard deviation [SD], 240 ml) in the auto-FTA group and 810 ml (SD, 341 ml) in the control group; the difference was significant (230 ml, p<0.001). The decrease in haemoglobin concentration was 17 g/l (SD, 11 g/l) in the auto-FTA group and 22 g/l (SD, 12 g/l) in the control group. The difference was significant (5 g/l, p=0.03). The percentage of total blood loss of >1200 ml in any single patient was significantly lower in the auto-FTA group (4%) than in the control group (20%) [p=0.01]. Auto-FTA is a safe and effective means of reducing perioperative blood loss in THA.

  11. Results of revision total knee arthroplasty using press-fit cementless stem.

    PubMed

    Iamaguchi, Maurício Masasi; de Castro, Fernando Bley Vicente; Gobbi, Riccardo Gomes; Tirico, Luis Eduardo Passarelli; Pécora, José Ricardo; Camanho, Gilberto Luis

    2013-01-01

    To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty. Thirty-four patients (35 knees) underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years) with a maximum length of three years. Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment. There was postoperative clinical and functional improvement in comparison to the preoperative status in revision total knee arthroplasty with press-fit cementless stem. Level of Evidence IV, Case series.

  12. The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Burgo, F J; Mengelle, D E; Ozols, A; Fernandez, C; Autorino, C M

    2016-11-01

    Studies reporting specifically on squeaking in total hip arthroplasty have focused on cementless, and not on hybrid, fixation. We hypothesised that the cement mantle of the femur might have a damping effect on the sound transmitted through the metal stem. The objective of this study was to test the effect of cement on sound propagation along different stem designs and under different fixation conditions. An in vitro model for sound detection, composed of a mechanical suspension structure and a sound-registering electronic assembly, was designed. A pulse of sound in the audible range was propagated along bare stems and stems implanted in cadaveric bone femurs with and without cement. Two stems of different alloy and geometry were compared. The magnitudes of the maximum amplitudes of the bare stem were in the range of 10.8 V to 11.8 V, whereas the amplitudes for the same stems with a cement mantle in a cadaveric bone decreased to 0.3 V to 0.7 V, implying a pulse-attenuation efficiency of greater than 97%. The same magnitude is close to 40% when the comparison is made against stems implanted in cadaveric bone femurs without cement. The in vitro model presented here has shown that the cement had a remarkable effect on sound attenuation and a strong energy absorption in cement mantle and bone. The visco-elastic properties of cement can contribute to the dissipation of vibro-acoustic energy, thus preventing hip prostheses from squeaking. This could explain, at least in part, the lack of reports of squeaking when hybrid fixation is used.Cite this article: F. J. Burgo, D. E. Mengelle, A. Ozols, C. Fernandez, C. M. Autorino. The damping effect of cement as a potential mitigation factor of squeaking in ceramic-on-ceramic total hip arthroplasty. Bone Joint Res 2016;5:531-537. DOI: 10.1302/2046-3758.511.BJR-2016-0058.R1. © 2016 Burgo et al.

  13. Cementless fixation of "isoelastic" hip endoprostheses manufactured from plastic materials.

    PubMed

    Morscher, E W; Dick, W

    1983-06-01

    Nine years of clinical experience with an "isoelastic" shaft prosthesis manufactured using polyacetal resin reveal that for the transmission of forces from the pelvis through the femoral head and neck into the femoral shaft, some rigidity of the proximal part of the prosthesis is necessary. The object is to eliminate micromovements, which lead to bone resorption and implant loosening. However, elasticity greater than that present in metallic implants prevents stress concentrations and disuse stress protection atrophy of the bone. Greater elasticity of the prosthesis, which can be achieved by plastic materials, makes possible a more even, harmonious distribution of the forces transmitted from the implant to the bone and vice versa. A more elastic implant can also act as a better shock absorber than a rigid one. The results in 627 cementless polyethylene cups after a maximum observation period of 5.5 years reveal good incorporation and no aseptic loosening. Especially favorable results occurred in 61 cases by replacing loosened cemented cups with bone grafts and cementless polyethylene cups. On the femoral shaft side too high an elasticity in the proximal part of the prosthesis led to bone resorption and loosening with the first model of the prosthesis. By reinforcing the proximal part of the femoral component, much better results were obtained. The isoelastic femoral shaft, however, is in an early stage of experimentation.

  14. Bone remodelling around HA-coated acetabular cups

    PubMed Central

    Nielsen, P. T.; Søballe, K.

    2006-01-01

    This study was designed to investigate bone remodelling around the cup in cementless THA. Previous studies indicate an advantage of better sealing of the bone-prosthesis interface by HA/TCP coating of implants, inhibiting polyethylene-induced osteolysis. One hundred patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy versus Trilogy Calcicoat (HA/TCP coated). The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric), with a modular 28-mm CrCo head. The Harris Hip Score (HHS) and bone mineral density (BMD) determined by DEXA scanning were used to study the effect. Measurements revealed no difference between the two groups after 3 years either in the clinical outcome or in terms of periprosthetic bone density. Patients with a body mass index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodelling. PMID:16761153

  15. Optimization of custom cementless stem using finite element analysis and elastic modulus distribution for reducing stress-shielding effect.

    PubMed

    Saravana Kumar, Gurunathan; George, Subin Philip

    2017-02-01

    This work proposes a methodology involving stiffness optimization for subject-specific cementless hip implant design based on finite element analysis for reducing stress-shielding effect. To assess the change in the stress-strain state of the femur and the resulting stress-shielding effect due to insertion of the implant, a finite element analysis of the resected femur with implant assembly is carried out for a clinically relevant loading condition. Selecting the von Mises stress as the criterion for discriminating regions for elastic modulus difference, a stiffness minimization method was employed by varying the elastic modulus distribution in custom implant stem. The stiffness minimization problem is formulated as material distribution problem without explicitly penalizing partial volume elements. This formulation enables designs that could be fabricated using additive manufacturing to make porous implant with varying levels of porosity. Stress-shielding effect, measured as difference between the von Mises stress in the intact and implanted femur, decreased as the elastic modulus distribution is optimized.

  16. [Application of bilateral direct anterior approach total hip arthroplasty: a report of 22 cases].

    PubMed

    Tang, J; Lv, M; Zhou, Y X; Zhang, J

    2017-04-18

    To analyze the operation technique and the methods to avoid early complications on the learning curve for bilateral direct anterior approach (DAA) total hip arthroplasty (THA). We retrospectively studied a series of continued cases with bilateral avascular necrosis of the femoral head (AVN) or degenerative dysplastic hip and rheumatoid arthritis that were treated by DAA THA in Beijing Jishuitan Hospital. A total of 22 patients with 44 hips were analyzed from June 2014 to August 2016 in this study. There were 17 males and 5 females, and the median age was 48 years (range: 34-67 years). All the surgery was done by DAA method by two senior surgeons. The clinic characters, early surgery treatment results and complications were analyzed. We used the cementless stems in all the cases. The average operating time was (167±23) min; the average blood loss was (775±300) mL;the blood transfusion was in average (327±341) mL; the wound drainage in average was (111±73) mL. Most of the patients could move out of the bed by themselves on the first day after operation, 5 patients could walk without crutches on the first operating day, and 13 patients could squat on the third days after operation. The patients were discharged averagely 4 days after operation. We followed up all the patients for averagely 16 months (range: 8-24 months). There was no loosening or failure case in the latest follow up. In the study, 2 patients had great trochanter fracture, 2 patients had thigh pain, 4 patients had lateral femoral cutaneous nerve palsy, and 3 patients had muscle damage. The Harris scores were improved from 29±8 preoperatively to 90±3 postoperatively (P<0.01). The DAA THA can achieve faster recovery and flexible hip joint after operation. However it is a kind of surgery with high technique demanding. Carefully selected patients, and skilled technique, can help the surgeon avoid the early complications. It is associated with high complication rate in the learning curve for bilateral DAA THA.

  17. Cementless modular intramedullary nail without bone-on-bone fusion as a salvage procedure in chronically infected total knee prosthesis: long-term results.

    PubMed

    Scarponi, Sara; Drago, Lorenzo; Romanò, Delia; Logoluso, Nicola; Peccati, Andrea; Meani, Enzo; Romanò, Carlo L

    2014-02-01

    Our purpose was to evaluate long-term results of two-stage cementless intramedullary nailing without achieving bone-to-bone fusion for treating chronically infected total knee arthroplasty (TKA). Thirty-eight patients treated according to the same protocol were retrospectively evaluated for clinical, functional, laboratory and radiological outcomes. Spacer exchange was necessary for infection persistence in one case. At a minimum two year follow-up, 34 patients (89.5%) showed no infection recurrence; among these 34 patients, 29 (85.3%) reported no or moderate pain [visual analogue scale (VAS) ≤3]; mild to moderate handicap (Lequesne Algofunctional Index < 7.5) was observed in 18 patients (52.9%). No patient underwent revision for aseptic loosening, and no nail breakage was observed. Two-stage cementless intramedullary nailing without achieving bone-to-bone fusion is a viable option for treating chronically infected TKA in selected, complex cases.

  18. Bone scans after total knee arthroplasty in asymptomatic patients. Cemented versus cementless

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hofmann, A.A.; Wyatt, R.W.; Daniels, A.U.

    1990-02-01

    The natural history of bone scans after total knee arthroplasty (TKA) was studied in 26 patients with 28 cemented TKAs and 29 patients with 31 cementless TKAs. The bone scans were examined at specified postoperative intervals. Radionuclide activity of the femoral, tibial, and patellar regions was measured. Six patients who developed pain postoperatively were excluded. Bone scans immediately postoperative and at three months demonstrated increased uptake, which gradually decreased to baseline levels at ten to 12 months. Radioisotope uptake was comparable in the cemented and cementless groups, but was highly variable in individual patients and in each of the follow-upmore » periods. A single postoperative bone scan cannot differentiate component loosening from early bone remodeling. Sequential bone scans, as a supplement to the clinical examination and conventional radiography, may prove useful in the diagnosis of TKA failure.« less

  19. Modern dual-mobility cup implanted with an uncemented stem: about 100 cases with 12-year follow-up.

    PubMed

    Philippot, Remi; Meucci, Jean Francois; Boyer, Bertrand; Farizon, Frederic

    2013-09-01

    We report the results of a 12-year follow-up retrospective series of 100 total hip arthroplasties using cementless, press-fit, dual-mobility acetabular cups. The aim of our study was to evaluate the clinical and radiographic results of this acetabular cup at last follow-up. This continuous and homogeneous series included 100 primary total hip arthroplasties performed during the year 2000. The THA combined a Corail® stem (Corail®, Depuy, Warsaw, IN) with a stainless steel Novae Sunfit® (Serf, Decines, France) acetabular cup. Fifteen patients died and 2 were lost to follow-up. Two cases of early dislocation were observed, and 3 cases of aseptic loosening of the acetabular component were reported. The mean stem subsidence was 0.71 mm, the mean craniopodal acetabular migration was 1.37 mm, and the mean medio-lateral acetabular migration was 1.52 mm. The 12-year survivorship is comparable to the data from the literature. The low dislocation rate at 12 years confirms the long-term, high stability of dual mobility, which should be recommended in primary THA for patients at risk for postoperative instability. The absence of true intraprosthetic dislocation events at 12-year follow-up provides evidence of the good quality of the latest generation of polyethylene liners and the necessity of combining thin-mirror, polished femoral necks with dual-mobility cups.

  20. Influence of different sizes of composite femora on the biomechanical behavior of cementless hip prosthesis.

    PubMed

    Schmidutz, Florian; Woiczinski, Mathias; Kistler, Manuel; Schröder, Christian; Jansson, Volkmar; Fottner, Andreas

    2017-01-01

    For the biomechanical evaluation of cementless stems different sizes of composite femurs have been used in the literature. However, the impact of different specimen sizes on test results is unknown. To determine the potential effect of femur size the biomechanical properties of a conventional stem (CLS Spotorno) were examined in 3 different sizes (small, medium and large composite Sawbones®). Primary stability was tested under physiologically adapted dynamic loading conditions measuring 3-dimensional micromotions. For the small composite femur the dynamic load needed to be adapted since fractures occurred when reaching 1700N. Additionally, surface strain distribution was recorded before and after implantation to draw conclusions about the tendency for stress shielding. All tested sizes revealed similar micromotions only reaching a significant different level at one measurement point. The highest micromotions were observed at the tip of the stems exceeding the limit for osseous integration of 150μm. Regarding strain distribution the highest strain reduction after implantation was registered in all sizes at the level of the lesser trochanter. Specimen size seems to be a minor influence factor for biomechanical evaluation of cementless stems. However, the small composite femur is less suitable for biomechanical testing since this size failed under physiological adapted loads. For the CLS Spotorno osseous integration is unlikely at the tip of the stem and the tendency for stress shielding is the highest at the level of the lesser trochanter. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Initial mechanical stability of cementless highly-porous titanium tibial components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stone, Timothy Brandon; Amer, Luke D; Warren, Christopher P

    Cementless fixation in total knee replacement has seen limited use since reports of early failure surfaced in the late 80s and early 90s. However the emergence of improved biomaterials, particularly porous titanium and tantalum, has led to a renewed interest in developing a cementless tibial component to enhance long-term survivorship of the implants. Cement is commonly employed to minimize micromotion in new implants but represents a weak interface between the implant and bone. The elimination of cement and application of these new biomaterials, which theoretically provide improved stability and ultimate osseointegration, would likely result in greater knee replacement success. Additionally,more » the removal of cement from the procedure would help minimize surgical durations and get rid of the time needed for curing, thereby the chance of infection. The purpose of this biomechanical study was twofold. The first goal was to assess whether vibration analysis techniques can be used to evaluate and characterize initial mechanical stability of cementless implants more accurately than the traditional method of micromotion determination, which employs linear variable differential transducers (LVDTs). Second, an evaluative study was performed to determine the comparative mechanical stability of five designs of cementless tibial components under mechanical loading designed to simulate in vivo forces. The test groups will include a cemented Triathlon Keeled baseplate control group, three different 2-peg cementless baseplates with smooth, mid, and high roughnesses and a 4-peg cement/ess baseplate with mid-roughness.« less

  2. Early Experience with a Short, Tapered Titanium Porous Plasma Sprayed Stem with Updated Design.

    PubMed

    Lombardi, Adolph V; Manocchio, Antonio G; Berend, Keith R; Morris, Michael J; Adams, Joanne B

    2018-06-01

    Short stem femoral components in primary total hip arthroplasty (THA) have increased in popularity since the advent of minimally invasive surgical techniques. The concept of a short stem is particularly compatible with tapered designs where the goal is to offload forces proximally in the femur. The purpose of this retrospective review was to review our early experience with a short, tapered titanium femoral component with updated design features. Beginning in November 2011 through February 2012, 92 consented patients (93 hips), at a single center, were treated with primary cementless THA using a short stem, tapered femoral component (Taperloc® Complete Microplasty; Zimmer Biomet, Warsaw, Indiana) and were available for review with a minimum two-year follow-up. Mean patient age at surgery was 63.2 years and body mass index (BMI) was 30.8 kg/m2. Mean stem length used was 110.3mm (range, 95-125). Mean follow-up was 4.5 years (2-6). Harris hip scores improved from 52.5 preoperatively to 84.7 at most recent. One stem was revised the same day for periprosthetic fracture. One patient with early infection was treated with single-stage exchange followed by recurrence that was treated successfully with two-stage exchange. A non-healing wound in one patient was treated with incision and debridement. Radiographic assessment demonstrated no evidence of loosening, osteolysis, distal hypertrophy, or pedestal formation in any hip, and all components appeared well fixed and in appropriate alignment. In this series of patients treated with primary THA using a short, tapered titanium porous plasma-sprayed femoral component with updated design features, good results were achieved with a low incidence of complications and revision. No aseptic loosening or osteolysis has occurred. Radiographic assessment was excellent for all patients.

  3. A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

    PubMed

    Molli, Ryan G; Lombardi, Adolph V; Berend, Keith R; Adams, Joanne B; Sneller, Michael A

    2012-02-01

    While short-stem design is not a new concept, interest has surged with increasing utilization of less invasive techniques. Short stems are easier to insert through small incisions. Reliable long-term results including functional improvement, pain relief, and implant survival have been reported with standard tapered stems, but will a short taper perform as well? We compared short, flat-wedge, tapered, broach-only femoral stems to standard-length, double-tapered, ream and broach femoral stems in terms of intraoperative complications, short-term survivorship, and pain and function scores. We retrospectively reviewed the records of 606 patients who had 658 THAs using a less invasive direct lateral approach from January 2006 to March 2008. Three hundred sixty patients (389 hips) had standard-length stems and 246 (269 hips) had short stems. Age averaged 63 years, and body mass index averaged 30.7 kg/m(2). We recorded complications and pain and function scores and computed short-term survival. Minimum followup was 0.8 months (mean, 29.2 months; range, 0.8-62.2 months). We observed a higher rate of intraoperative complications with the standard-length stems (3.1%; three trochanteric avulsions, nine femoral fractures) compared with the shorter stems (0.4%; one femoral fracture) and managed all complications with application of one or more cerclage cables. There were no differences in implant survival, Harris hip score, and Lower Extremity Activity Scale score between groups. Fewer intraoperative complications occurred with the short stems, attesting to the easier insertion of these devices. While longer followup is required, our early results suggest shortened stems can be used with low complication rates and do not compromise the survival and functional outcome of cementless THA. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  4. Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants.

    PubMed

    Harwin, Steven F; Patel, Nirav K; Chughtai, Morad; Khlopas, Anton; Ramkumar, Prem N; Roche, Martin; Mont, Michael A

    2017-07-01

    Newer generation cementless total knee arthroplasty (TKA) designs are available and have novel implant coatings. We evaluated and compared beaded periapatite (PA)-coated vs highly porous titanium-coated cementless TKAs. Specifically, we compared: (1) survivorship, (2) Knee Society Scores (KSSs) and range of motion, (3) complications, and (4) radiographic findings. There were 805 TKAs with beaded PA-coated tibial and patellar components (PA group; mean age 67 years; range 41-86 years), and 219 TKAs with highly porous titanium-coated tibial and patella components (mean age 66 years; range 34-88 years). Mean follow-up was 4.4 years (range 2-9 years; median 4 years). Implant survivorship was calculated using Kaplan-Meier curves. Student t-tests and chi-square tests were used as appropriate. Radiographic evaluation was performed using Knee Society Roentgenographic Evaluation and Scoring System. All-cause implant survivorship in beaded PA-coated group was 99.5% (95% CI, 97.9%-99.9%) and 99.5% (95% CI, 92.7%-99.9%) in highly porous titanium-coated group. There were no significant differences in the KSS for pain and function. Improvement in flexion and extension was similar in the 2 groups. Overall, complication rate (2.2% vs 2.3%; P = .274) and number of revisions (6 [0.8%] vs 2 [0.2%]; P = .936) were similar in the 2 groups. Excluding the aseptic and septic failures, there were no progressive radiolucencies or osteolysis on radiographic evaluation. This study has shown good clinical and patient-reported outcomes of cementless TKA for both implants. Future multicenter large scale clinical and cost-effectiveness studies are needed to determine the superiority of one cementless implant type over the other. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. CCD and offset after Nanos short stem in total hip arthroplasty.

    PubMed

    Ettinger, M; Ettinger, P; Ezechieli, M; Büermann, S; Budde, S; Calließ, T; Petri, M; Thorey, F

    2013-01-01

    Many short stems for total hip arthroplasty have been introduced by the manufacturers only during the last decade. One of them is the Nanos short stem (Smith and Nephew, Marl, Germany). The development of short stems was aimed at preserving bone and soft tissue by utilizing a minimally invasive approach, thus allowing a quick return to an active life. It was purpose of this study to evaluate the radiological changes after using this device. We present the radiological results of 202 cementless THAs which were performed in 172 patients using the Nanos stem. Radiological evaluation was performed using standing anterior-posterior (AP) and lateral radiographs of the proximal femur preoperatively, postoperatively and during the follow up. We analyzed the preoperative and postoperativ CCD angle, the subsisdence, preoperative and postoperative offset, osteolysis, bone resorption, increased density, neocortex and periarthricular ossifications. One stem had to be revised due to subsidence four days after implantation. Two cups (BiconPlus, Smith and Nephew, Marl, Germany) had to be revised during the time of follow up due to an aseptic cup loosening. Two stems showed radiolucent lines at the implant-bone-interface at the last follow-up. An increase of bone density could be detected in 18 hips (8.9%). 14 hips showed periarticular ossifications. Measurable subsidence was detected in a total of four stems (1.9%). The preoperative neck-shaft-angle angle was 133.8 ± 4.4° (range: 118.5-146.2) and the neck-shaft-angle angle at the time of follow up was 134.6 ± 4.3° (range: 123.3-147; P< 0.05). The preoperative and postoperative offset changed from 109.3 ± 11.9 mm (range: 80.9-131.6) to 109.7 ± 12.3 mm (range: 79.7-155.6; P< 0.05). In summary, this study shows that a correct anatomical reconstruction is possible with a device of this design. The outcome is comparable to that of other short stems. Further studies should be performed in a prospective and randomized design to evaluate the advantage of such a device with a higher level of evidence.

  6. Cementless Total Knee Arthroplasty in Patients Older Than 75 Years.

    PubMed

    Newman, Jared M; Khlopas, Anton; Chughtai, Morad; Gwam, Chukwuweike U; Mistry, Jaydev B; Yakubek, George A; Harwin, Steven F; Mont, Michael A

    2017-11-01

    Some surgeons have been hesitant to use cementless fixation for total knee arthroplasty (TKA) in elderly patients due to concerns regarding successful bone biological fixation. Therefore, this study evaluated: (1) implant survivorship, (2) functional outcomes, (3) radiographic outcomes, and (4) complications in patients over 75 years of age who underwent cementless total knee arthroplasty. A total of 134 patients (142 TKAs) older than 75 years at a single institution between June 2008 and June 2014 were retrospectively reviewed. Their mean follow-up was 4 years (range: 2-8 years). The cohort consisted of 91 women and 43 men who had a mean age of 80 years (range: 76 to 88 years). The preoperative diagnoses were osteoarthritis ( n  = 107 patients), rheumatoid arthritis ( n  = 21 patients), and osteonecrosis ( n  = 6 patients). Descriptive statistics were used to calculate the means and ranges and a Kaplan-Meier analysis was performed to determine the aseptic and all cause implant survivorship. Radiographic evaluation was performed using the new Knee Society Radiographic Evaluation and Scoring System. Functional outcomes at the final follow-up as well as all medical and surgical complications were recorded for each patient. The aseptic implant survivorship was 99.3% (95% CI: 7.9-8.1), and the all cause implant survivorship was 98.6% (95% CI: 7.9-8.1). There was one aseptic revision and one septic revision. At the latest follow-up the mean Knee Society pain score was 93 points (range, 80-100 points), and the mean Knee Society function score was 84 points (range, 70-90 points). On radiographic evaluation, there were no progressive radiolucencies, subsidence, and loosening of prostheses at the latest follow-up. The use of cementless TKA demonstrated excellent survivorship, mid-term clinical and functional outcomes, as well as no progressive radiolucencies or subsidence in patients older than 75 years. In addition, there was a low rate of surgical and medical complications. Therefore, cementless TKA may be a good option for patients older than 75 years. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. [Acetabular Osteolysis in Total Hip Replacement - When to Retain the Cup?].

    PubMed

    Lutz, B; Faschingbauer, M; Bieger, R; Reichel, H; Kappe, T

    2016-08-01

    Periacetabular osteolysis is a frequent long-term complication of cementless total hip arthroplasty. The decision whether to retain or to revise a cup in the presence of osteolysis remains a challenge. The options are regular clinical and radiological check-ups, isolated liner exchange with and without bone grafting, and complete cup revision. Thorough preoperative diagnostics, including a medical history, examination and imaging, are mandatory for correct decision making. In most patients, computed tomography is useful to assess periacetabular osteolysis. If the cup is well-fixed and positioned in an asymptomatic patient without progressive osteolysis and no implant defect or higher grade polyethylene wear and no signs of infection, continuous clinical and radiological monitoring is preferred. If imaging reveals cup loosening, malposition, osteolysis localised in a weight-bearing area, imminent or present periprosthetic fractures, rapid progressive osteolysis, implant defects or massive inlay wear, surgical treatment may be preferred. Cup revision is usually performed in such patients. If the cup is well-positioned and well-fixed in the X-ray, the procedure has to be discussed with the patient individually. Apart from patient-specific risk factors, the risk of further progression has to be assessed. Isolated liner exchange can be performed if the patient is asymptomatic and the cup proves to be stable intraoperatively. It is still unclear whether filling osteolyses through screw holes or osseous windows is of long-term benefit. Georg Thieme Verlag KG Stuttgart · New York.

  8. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

    PubMed

    Craiovan, B; Weber, M; Worlicek, M; Schneider, M; Springorum, H R; Zeman, F; Grifka, J; Renkawitz, T

    2016-06-01

    The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and compared with a 3D-CT based reconstruction model within the same radiographic coronal plane. The mean difference between the radiographic and the 3D-CT measurements was - 1.4° ± 3.9° for inclination and 0.8°± 7.9° for anteversion with excellent correlation for inclination (r = 0.81, p < 0.001) and moderate correlation for anteversion (r = 0.65, p < 0.001). The intraclass correlation coefficient for measurements on radiographs ranged from 0.98 (95 %-CI: 0.98; 0.99) for the first observer to 0.94 (95 %-CI: 0.92; 0.96) for the second observer. The interrater reliability was 0.96 (95 %-CI: 0.93; 0.98) for inclination and 0.93 (95 %-CI: 0.85; 0.96) for anteversion. The largest errors in measurements were associated with an extraordinary pelvic tilt. In order to get a valuable measurement for measuring cup position after THA on pelvic radiographs by this vector arithmetic method, there is a need for a correct postoperative ap view, with special regards to the pelvic tilt for the future. • Measuring acetabular cup orientation on anteroposterior radiographs of the hip after THA is a helpful procedure in everyday clinical practice as a first-line imaging modality• CT remains the golden standard to accurately determine acetabular cup position.• Future measuring on radiographs for cup orientation after THA should account for integration of the pelvic tilt in order to maximize the measurement accuracy. Citation Format: • Craiovan B, Weber M, Worlicek M et al. Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?. Fortschr Röntgenstr 2016; 188: 574 - 581. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Computer-assisted hip and knee arthroplasty. Navigation and active robotic systems: an evidence-based analysis.

    PubMed

    2004-01-01

    The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. NAVIGATION-ASSISTED ARTHROPLASTY: Five studies were identified that examined navigation-assisted arthroplasty.A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1)A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2)A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3)Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that "the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques."(4;5) ROBOTIC-ASSISTED ARTHROPLASTY: Four studies were identified that examined robotic-assisted arthroplasty.A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6)Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6)Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6)Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6)An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7)An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8)An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9).

  10. Computer-Assisted Hip and Knee Arthroplasty. Navigation and Active Robotic Systems

    PubMed Central

    2004-01-01

    Executive Summary Objective The Medical Advisory Secretariat undertook a review of the evidence on the effectiveness and cost-effectiveness of computer assisted hip and knee arthroplasty. The two computer assisted arthroplasty systems that are the topics of this review are (1) navigation and (2) robotic-assisted hip and knee arthroplasty. The Technology Computer-assisted arthroplasty consists of navigation and robotic systems. Surgical navigation is a visualization system that provides positional information about surgical tools or implants relative to a target bone on a computer display. Most of the navigation-assisted arthroplasty devices that are the subject of this review are licensed by Health Canada. Robotic systems are active robots that mill bone according to information from a computer-assisted navigation system. The robotic-assisted arthroplasty devices that are the subject of this review are not currently licensed by Health Canada. Review Strategy The Cochrane and International Network of Agencies for Health Technology Assessment databases did not identify any health technology assessments on navigation or robotic-assisted hip or knee arthroplasty. The MEDLINE and EMBASE databases were searched for articles published between January 1, 1996 and November 30, 2003. This search produced 367 studies, of which 9 met the inclusion criteria. Summary of Findings Navigation-Assisted Arthroplasty Five studies were identified that examined navigation-assisted arthroplasty. A Level 1 evidence study from Germany found a statistically significant difference in alignment and angular deviation between navigation-assisted and free-hand total knee arthroplasty in favour of navigation-assisted surgery. However, the endpoints in this study were short-term. To date, the long-term effects (need for revision, implant longevity, pain, functional performance) are unknown.(1) A Level 2 evidence short-term study found that navigation-assisted total knee arthroplasty was significantly better than a non-navigated procedure for one of five postoperative measured angles.(2) A Level 2 evidence short-term study found no statistically significant difference in the variation of the abduction angle between navigation-assisted and conventional total hip arthroplasty.(3) Level 3 evidence observational studies of navigation-assisted total knee arthroplasty and unicompartmental knee arthroplasty have been conducted. Two studies reported that “the follow-up of the navigated prostheses is currently too short to know if clinical outcome or survival rates are improved. Longer follow-up is required to determine the respective advantages and disadvantages of both techniques.”(4;5) Robotic-Assisted Arthroplasty Four studies were identified that examined robotic-assisted arthroplasty. A Level 1 evidence study revealed that there was no statistically significant difference between functional hip scores at 24 months post implantation between patients who underwent robotic-assisted primary hip arthroplasty and those that were treated with manual implantation.(6) Robotic-assisted arthroplasty had advantages in terms of preoperative planning and the accuracy of the intraoperative procedure.(6) Patients who underwent robotic-assisted hip arthroplasty had a higher dislocation rate and more revisions.(6) Robotic-assisted arthroplasty may prove effective with certain prostheses (e.g., anatomic) because their use may result in less muscle detachment.(6) An observational study (Level 3 evidence) found that the incidence of severe embolic events during hip relocation was lower with robotic arthroplasty than with manual surgery.(7) An observational study (Level 3 evidence) found that there was no significant difference in gait analyses of patients who underwent robotic-assisted total hip arthroplasty using robotic surgery compared to patients who were treated with conventional cementless total hip arthroplasty.(8) An observational study (Level 3 evidence) compared outcomes of total knee arthroplasty between patients undergoing robotic surgery and patients who were historical controls. Brief, qualitative results suggested that there was much broader variation of angles after manual total knee arthroplasty compared to the robotic technique and that there was no difference in knee functional scores or implant position at the 3 and 6 month follow-up.(9) PMID:23074452

  11. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    PubMed

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  12. Impact of implant size on cement filling in hip resurfacing arthroplasty.

    PubMed

    de Haan, Roel; Buls, Nico; Scheerlinck, Thierry

    2014-01-01

    Larger proportions of cement within femoral resurfacing implants might result in thermal bone necrosis. We postulate that smaller components are filled with proportionally more cement, causing an elevated failure rate. A total of 19 femoral heads were fitted with polymeric replicas of ReCap (Biomet) resurfacing components fixed with low-viscosity cement. Two specimens were used for each even size between 40 and 56 mm and one for size 58 mm. All specimens were imaged with computed tomography, and the cement thickness and bone density were analyzed. The average cement mantle thickness was 2.63 mm and was not correlated with the implant size. However, specimen with low bone density had thicker cement mantles regardless of size. The average filling index was 36.65% and was correlated to both implant size and bone density. Smaller implants and specimens with lower bone density contained proportionally more cement than larger implants. According to a linear regression model, bone density but not implant size influenced cement thickness. However, both implant size and bone density had a significant impact on the filling index. Large proportions of cement within the resurfacing head have the potential to generate thermal bone necrosis and implant failure. When considering hip resurfacing in patients with a small femoral head and/or osteoporotic bone, extra care should be taken to avoid thermal bone necrosis, and alternative cementing techniques or even cementless implants should be considered. This study should help delimiting the indications for hip resurfacing and to choose an optimal cementing technique taking implant size into account.

  13. Total knee replacement-cementless tibial fixation with screws: 10-year results.

    PubMed

    Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım

    2017-12-01

    The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  14. Hip arthroplasty today and tomorrow.

    PubMed

    Amstutz, H C

    1987-12-01

    Acrylic-fixed total hip and surface replacement arthroplasty have been very effective in affording immediate relief of pain and providing improved function. Complications have been reduced by improvements in design, materials, and especially technique. They are now very low in the elderly, and the stem type acrylic-fixed design remains the procedure of choice. The failure rates in youthful patients and those with bone-stock deficiencies have been high in both THR and surface types, although the latter had the advantage of preserving femoral stock. On the femoral side, the new "macro" femoral designs from Europe and "micro" femoral porous designs have shown promise, but thigh pain, incomplete and difficult to predict bone ingrowth patterns, coupled with removal problems have influenced design and technique changes. Both press-fit stem types and porous surface replacements have produced promising initial results with less potential downside risks. On the acetabular side, both the cementless hemispherical with screw-type adjuvant fixation, or the chamfered cylinder designs, used primarily with the UCLA porous surface replacements, but also with stem-type devices, appear to achieve best short-term results, while the entire variety of screw rings are disappointing. The future will bring further refinements in technique and specific indications for certain types of replacement stem in specific types of bone stock deficiencies. The all ceramic-ceramic and ceramic-polyethylene bearings show promise of reducing wear and, hence, should improve longevity of implant fixation.

  15. R3 Cup Does Not Have a High Failure Rate in Conventional Bearings: A Minimum of 5-Year Follow-Up.

    PubMed

    Teoh, Kar H; Whitham, Robert D J; Golding, David M; Wong, Jenny F; Lee, Paul Y F; Evans, Aled R

    2018-02-01

    The R3 cementless acetabular system was first marketed in Australia and Europe in 2007. Previous papers have shown high failure rates of the R3 cup with up to 24% with metal-on-metal bearing. There are currently no medium term clinical results on this cup. The aim of the study is to review our results of the R3 acetabular cup with conventional bearings with a minimum of 5-year follow-up. Patients who were implanted with the R3 acetabular cup were identified from our center's arthroplasty database. A total of 293 consecutive total hip arthroplasties were performed in 286 patients. The primary outcome was revision. The secondary outcomes were the Oxford Hip Scores (OHS) and radiographic evaluation. The mean age of the patients was 69.4 years. The mean preoperative OHS was 23 (range 10-34) and the mean OHS was 40 (range 33-48) at the final follow-up. Radiological evaluation showed an excellent ARA score in all patients at 5 years. None of the R3 cups showed osteolysis at the final follow-up. There were 3 revisions in our series, of which 2 R3 cups were revised. The risk of revision was 1.11% at 5 years. Our experience of using the R3 acetabular system with conventional bearings showed high survivorship and is consistent with the allocated Orthopaedic Data Evaluation Panel rating of 5A* as rated in 2015 in the United Kingdom. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. The effect of bearing friction torques on the primary stability of press-fit acetabular cups: A novel in vitro method.

    PubMed

    Alexander, Jahnke; Stefan, Schroeder; Alfonso, Fonseca Ulloa Carlos; Adam, Ahmed Gafar; Alexander, Ishaque Bernd; Markus, Rickert

    2018-05-10

    Aseptic loosening is the main reason for revision of total hip arthroplasty, and relative micromotions between cementless acetabular cups and bone play an important role regarding their comparatively high loosening rate. Therefore, the aim of the present study was to analyze the influence of resulting frictional torques on the primary stability of press-fit acetabular cups subjected to two different bearing partners. A cementless press-fit cup was implanted in bone-like foam. Primary stability of the cup was analyzed by determining spatial total, translational and rotational interface micromotions by means of an eddy current sensor measuring system. Torque transmission into the cup was realized by three synchronous servomotors considering resultant friction torques based on constant friction for ceramic-on-ceramic (CoC: µ = 0.044; max. resultant torque: 1.5 Nm) and for ceramic-on-polyethylene (CoP: µ = 0.063; max. resultant torque: 1.9 Nm) bearing partners. Rotational micromotion of CoC was 8.99 ± 0.85µm and of CoP 13.39 ± 1.43µm. Translational micromotion of CoC was 29.93 ± 1.44µm and of CoP 39.91 ± 2.25µm. Maximum total relative micromotions were 37.10 ± 1.07µm for CoC and 51.64 ± 2.18µm for CoP. Micromotions resulting from CoC were statistically lower than those resulting from CoP (p < 0.05). The described 3D-measuring set-up offers a novel in vitro method of measuring primary stability of acetabular cups. We can therefore conclude, that primary stability of acetabular cup systems can be observed using either the lower friction curve (CoC) or the higher friction curve (CoP). In future studies different cup designs or cup fixation mechanisms may be tested and compared in vitro and assessed prior to implantation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. [S3 Guideline. Part 3: Non-Traumatic Avascular Necrosis in Adults - Surgical Treatment of Atraumatic Avascular Femoral Head Necrosis in Adults].

    PubMed

    Maus, U; Roth, A; Tingart, M; Rader, C; Jäger, M; Nöth, U; Reppenhagen, S; Heiss, C; Beckmann, J

    2015-10-01

    The present article describes the guidelines for the surgical treatment of atraumatic avascular necrosis (aFKN). These include joint preserving and joint replacement procedures. As part of the targeted literature, 43 publications were included and evaluated to assess the surgical treatment. According to the GRADE and SIGN criteria level of evidence (LoE), grade of recommendation (EC) and expert consensus (EK) were listed for each statement and question. The analysed studies have shown that up to ARCO stage III, joint-preserving surgery can be performed. A particular joint-preserving surgery currently cannot be recommended as preferred method. The selection of the method depends on the extent of necrosis. Core decompression performed in stage ARCO I (reversible early stage) or stage ARCO II (irreversible early stage) with medial or central necrosis with an area of less than 30 % of the femoral head shows better results than conservative therapy. In ARCO stage III with infraction of the femoral head, the core decompression can be used for a short-term pain relief. For ARCO stage IIIC or stage IV core decompression should not be performed. In these cases, the indication for implantation of a total hip replacement should be checked. Additional therapeutic procedures (e.g., osteotomies) and innovative treatment options (advanced core decompression, autologous bone marrow, bone grafting, etc.) can be discussed in the individual case. In elective hip replacement complications and revision rates have been clearly declining for decades. In the case of an underlying aFKN, however, previous joint-preserving surgery (osteotomies and grafts in particular) can complicate the implantation of a THA significantly. However, the implant life seems to be dependent on the aetiology. Higher revision rates for avascular necrosis are particularly expected in sickle cell disease, Gaucher disease, or kidney transplantation patients. Furthermore, the relatively young age of the patient with avascular necrosis should be seen as the main risk factor for higher revision rate. The results after resurfacing (today with known restricted indications) and cemented as well as cementless THA in aFKN are comparable for the appropriate indication to those in coxarthrosis or other diagnoses. Regardless of the underlying disease endoprosthetic treatment in aFKN leads to good results. Both cemented and cementless fixation techniques can be recommended. Georg Thieme Verlag KG Stuttgart · New York.

  18. 10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.

    PubMed

    Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S

    2009-01-01

    We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.

  19. Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model

    PubMed Central

    Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen

    2015-01-01

    Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses. PMID:25695057

  20. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up.

    PubMed

    Yamanaka, Hajime; Goto, Ken-ichiro; Suzuki, Munetaka

    2012-02-22

    Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee.The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis.

  1. Does vitamin E-blended polyethylene reduce wear in primary total hip arthroplasty: a blinded randomised clinical trial.

    PubMed

    Scemama, Caroline; Anract, Philippe; Dumaine, Valérie; Babinet, Antoine; Courpied, Jean Pierre; Hamadouche, Moussa

    2017-06-01

    Some data indicate that first-generation highly cross-linked polyethylene (HXLPE) can oxidise in vivo and is associated with reduced mechanical properties. To overcome these limitations, a natural anti-oxidant vitamin E has been added to HXLPE to preserve the mechanical properties and decrease oxidative degradation whilst conserving high wear resistance. We hypothesised that after a minimal three years of follow-up the use of vitamin E-blended HXLPE would result in lower radiographic wear when compared with ultra-high molecular weight polyethylene (UHMWPE). One hundred patients were randomised to receive hybrid total hip arthroplasty (THA) using a monoblock cementless acetabular component made either of UHMWPE or vitamin E-blended HXLPE. All other parameters were identical in both groups. Complete follow-up was available for 74 of these patients. Femoral head penetration was measured using a validated computer-assisted method. The median creep measured 0.111 mm (range, -0.576 - +0.444 mm) in the vitamin E-blended group versus 0.170 mm (range, -0.861 - +0.884 mm) in the UHMWPE group (difference of medians, 0.059; p = 0.046). The median steady state penetration rate was -0.008 mm/year (range, -0.88 - +0.64 mm/year) in the vitamin E-blended group versus 0.133 mm/year (range, -0.84 - +0.85 mm/year) in the UHMWPE group (difference of medians 0.141, p = 0.043). This study demonstrated that femoral head penetration was lower when using vitamin E-blended HXLPE when compared with UHMWPE, with a steady-state penetration rate far below the osteolysis threshold. Longer-term follow-up is needed to warrant whether wear reduction will generate less occurrence of osteolysis and aseptic loosening.

  2. Integration of multi-objective structural optimization into cementless hip prosthesis design: Improved Austin-Moore model.

    PubMed

    Kharmanda, G

    2016-11-01

    A new strategy of multi-objective structural optimization is integrated into Austin-Moore prosthesis in order to improve its performance. The new resulting model is so-called Improved Austin-Moore. The topology optimization is considered as a conceptual design stage to sketch several kinds of hollow stems according to the daily loading cases. The shape optimization presents the detailed design stage considering several objectives. Here, A new multiplicative formulation is proposed as a performance scale in order to define the best compromise between several requirements. Numerical applications on 2D and 3D problems are carried out to show the advantages of the proposed model.

  3. Low Frequency of Early Complications With Dual-mobility Acetabular Cups in Cementless Primary THA.

    PubMed

    Chughtai, Morad; Mistry, Jaydev B; Diedrich, Aloise M; Jauregui, Julio J; Elmallah, Randa K; Bonutti, Peter M; Harwin, Steven F; Malkani, Arthur L; Kolisek, Frank R; Mont, Michael A

    2016-10-01

    Dislocation complicates 1% to 5% of primary total hip arthroplasties (THAs). As a result, some surgeons consider dual-mobility articulations, which are usually used in the revision setting to decrease the likelihood of dislocation, as an option for primary THA. However, few studies have evaluated their use in this setting. (1) What is the cup survivorship when the dual-mobility articulation is used in the setting of primary THA? (2) What are the clinical outcomes with this approach? (3) What are the radiographic outcomes? (4) What are the complications of dual-mobility articulations in primary THA? Between 2011 and 2013, the five participating surgeons performed 495 cementless primary THAs. During that time, one of the five surgeons used dual-mobility articulations for all THAs, and the other four used it whenever the acetabular cup size was 52 mm or greater to enable a 28-mm head. Of the 495 patients, 453 (92%) were performed using this device. Smaller patients were treated with a standard THA. Of the 453 patients, a total of 43 patients (10%) were lost to followup before the 2-year minimum. The resulting 410 patients who were included in the analysis (164 men, 246 women) had a mean age of 64 years (SD, 12 years). The mean followup was 3 years (SD, 0.7 years). We performed Kaplan-Meier analyses to assess survivorship to aseptic failure and all-cause acetabular component survivorship. Clinical outcomes were evaluated using the Harris hip score (HHS); radiographs were assessed for cup migration, progressive radiolucencies, and positional changes of the components; and any surgery-related complications were recorded. The survivorship to aseptic failure and all-cause acetabular component survivorship was 99.8% (failures, n = 1) (95% confidence interval [CI], 4.517-4.547) and 99.3% (failures, aseptic, n = 1; septic, n = 2) (95% CI, 4.494-4.543); one hip had trunnion notching caused by impingement of a malpositioned cup, which was treated with revision of the cup and stem; and two patients had periprosthetic infections that were treated with two-stage revisions. There were no dislocations. Patients had a mean HHS of 94 (SD, 6) at final followup. On radiographic evaluation, no progressive radiolucencies or positional changes of the components were identified. Surgical complications included one traumatic avulsion of the abductors, one traumatic avulsion of the greater trochanter, which was repaired without revision of any of the components, and one loose femoral stem, which required revision of the femoral component only. Dual-mobility cups in primary THA yield seemingly comparable survivorship and complications to conventional THA bearings at short-term followup. Because serious complications have occasionally been reported with the use of these bearings, larger, longer term, comparative-and ideally, randomized-trials will be needed to establish the superiority of one approach over the other. Until or unless such studies show the superiority of dual-mobility designs for primary THA, we recommend that in the setting of uncomplicated primary THA, dual-mobility articulations be used only in centers that track their results carefully or in research protocols. Level IV, therapeutic study.

  4. Removal of a well-fixed cementless femoral stem using a microsagittal saw.

    PubMed

    Kim, Young-Min; Lim, Soo Taek; Yoo, Jeong Joon; Kim, Hee Joong

    2003-06-01

    Well-fixed cementless femoral components are troublesome to extract. This article describes a technique to extract a well-fixed cementless stem in which the stem is extracted with a bent microsagittal saw blade after a longitudinal cortical window is made.

  5. Vanadium release in whole blood, serum and urine of patients implanted with a titanium alloy hip prosthesis.

    PubMed

    Catalani, S; Stea, S; Beraudi, A; Gilberti, M E; Bordini, B; Toni, A; Apostoli, P

    2013-08-01

    Vanadium (V) is a minor constituent of the Titanium-Aluminum-Vanadium (TiAlV) alloy currently used in cementless hip prostheses. Present study aimed at verifying the correlation of vanadium levels among different matrices and assessing reference levels of the ion in a population of patients wearing a well-functioning hip prosthesis. Vanadium was measured using Inductive Coupled Plasma Mass Spectrometry (ICP-MS) in whole blood, serum and urine of 129 patients implanted with a TiAlV-alloy hip prosthesis. The values in the serum were above the upper limit of the reference values in 42% of patients (29% in urine and 13% in whole blood). A good correlation among matrices was observed (p < 0.001). The cohort of patients (N = 32) complaining of pain or in which a loosening or damage to the prosthesis was assessed showed a significantly higher excretion of vanadium in urine as compared with the remaining asymptomatic patients (p = 0.001). The 95th percentile distribution of vanadium in the cohort of patients with a well-functioning prosthesis was 0.3 μg/L in whole blood, 0.5 μg/L in serum and 2.8 μg/L in urine, higher that in the unexposed population, especially for urine. The presence of a prosthesis, even though well-functioning, may cause a possible release of vanadium into the blood and a significant urinary excretion. The reference values of vanadium of the asymptomatic patients with titanium alloy hip prostheses supplied information regarding the background exposure level of the ions and their lower and upper limits.

  6. Total hip arthroplasty using a cementless dual-mobility cup provides increased stability and favorable gait parameters at five years follow-up.

    PubMed

    Acker, A; Fischer, J-F; Aminian, K; Lécureux, E; Jolles, B M

    2017-02-01

    Rates of dislocation following primary total hip arthroplasty (THA) vary from 0.5 to 10%. Dual-mobility cups in THA demonstrate increased stability. Clinical outcomes following THA with dual-mobility cups have been reported, but gait has not been assessed. Therefore we performed a retrospective case control study to answer: (1) is gait better in patients following THA with a dual-mobility cup than in frail, elderly patients of the same age? (2) Are clinical outcomes better in patients following THA with a dual-mobility cup than in frail, elderly patients? (3) What is the dislocation rate following THA with a dual-mobility cup? We hypothesized that patients who underwent THA with a dual-mobility cup have a better gait compared to frail, elderly patients of the same age. Twenty patients (22 hips), mean age 79.9±7.7 (range, 62.3-88.3) years were assessed in this retrospective case-control series 5.6±1.4 (range: 4.1-8.8) years following dual-mobility cup THA. A reference group consisted of 72 "frail elderly" patients in a rehabilitation hospital for health problems unrelated to the lower limb, with no lower limb surgery or neurological conditions. Temporal and spatial gait performance were measured with four miniature gyroscopes, mounted on each thigh and calf, while patients walked freely along a 30m corridor. Harris Hip Score, WOMAC, radiological outcomes, and dislocation rate were determined. All gait parameters were better in the dual-mobility group compared to the frail elderly group. The dual-mobility group had a higher cadence (100.3 steps/minute versus 75.6 steps/minute), shorter (relative to gait cycle time) stance (61.6% versus 67.8%), shorter (relative to gait cycle time) double stance (23.3% versus 36.0%), longer stride (1.13m versus 0.80m), and faster walking speed (0.96m/s versus 0.52m/s). Range of motion of the shank, thigh and knee were better in the dual-mobility group. Harris Hip Score was 87.6±13.9 (range 51-100) and WOMAC score was 11.3±12.1 (range 0-34) in the THA group. We observed no dislocations. Gait patterns five years following THA with the dual-mobility cup were better or comparable to published study populations. III, retrospective case-control series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    PubMed

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1.4%)] and steady-state wear rate. This study suggests that there are no adverse effects on the results of THA with HXLPE from the use of cups with screw holes and the use of screws for cup fixation. Level III retrospective case-control study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  8. Short stem survival after osteonecrosis of the femoral head.

    PubMed

    Schnurr, Christoph; Loucif, Anissa; Patzer, Theresa; Schellen, Bernd; Beckmann, Johannes; Eysel, Peer

    2018-04-01

    Short stems were developed as a bone-conserving alternative especially for the young hip arthroplasty patient. Patients suffering from osteonecrosis of the femoral head are frequently younger than primary arthritis patients. The outcome of short stems in these patients remains unclear. The aim of our study was to compare mid-term survival of short stems after osteonecrosis of the femoral head (ONFH) and primary arthritis. Data on short stem implantations over a 10-year period were collected. Demographic data and X-ray measurements before and after surgery were recorded. Indication for operation was determined from medical records and X-rays. Patients were asked by post about any revision. Reason for revision was identified by analysis of operation protocols. Short stem revision rates were analyzed using Kaplan-Meier charts, comparing 212 ONFH patients (231 operations) and 1284 primary arthritis patients (1455 operations). Follow-up time averaged 5.3 and 6 years and was complete for 92% (ONFH) and 94% (primary arthritis) of the patients. ONFH patients were significantly younger (53 years vs. 59 years, p < 0.001) and more frequently male (55 vs. 42%, p < 0.001). The total revision rate did not differ between the two groups (8 years: 4.2 vs. 5.6%, p = ns). A trend towards more stem revisions was detected for ONFH patients (3 vs. 1.8%, p = ns). The aseptic stem loosening rate was significantly elevated for osteonecrosis patients (8 years: 2.6 vs. 0.7%, p = 0.013). Our study showed elevated short stem loosening rates after ONFH. Similar results are published for classic cementless stems. The question of which stem is best for the young osteonecrosis patient cannot be answered yet. Consecutive studies directly comparing loosening rates of short and classic cementless stems in young osteonecrosis patients are required.

  9. Early Migration Predicts Aseptic Loosening of Cementless Femoral Stems: A Long-term Study.

    PubMed

    Streit, Marcus R; Haeussler, Daniel; Bruckner, Thomas; Proctor, Tanja; Innmann, Moritz M; Merle, Christian; Gotterbarm, Tobias; Weiss, Stefan

    2016-07-01

    Excessive early migration of cemented stems and cups after THA has been associated with poor long-term survival and allows predictable evaluation of implant performance. However, there are few data regarding the relationship between early migration and aseptic loosening of cementless femoral components, and whether early migration might predict late failure has not been evaluated, to our knowledge. Einzel-Bild-Röntgen-Analyse-femoral component analysis (EBRA-FCA) is a validated technique to accurately measure axial femoral stem migration without the need for tantalum markers, can be performed retrospectively, and may be a suitable tool to identify poor performing implants before their widespread use. We asked: (1) Is axial migration within the first 24 months as assessed by EBRA-FCA greater among cementless stems that develop aseptic loosening than those that remain well fixed through the second decade; (2) what is the diagnostic performance of implant migration at 24 months postoperatively to predict later aseptic loosening of these components; and (3) how does long-term stem survivorship compare between groups with high and low early migration? We evaluated early axial stem migration in 158 cementless THAs using EBRA-FCA. The EBRA-FCA measurements were performed during the first week postoperatively (baseline measurement) and at regular followups of 3, 6, and 12 months postoperatively and annually thereafter. The mean duration of followup was 21 years (range, 18-24 years). The stems studied represented 45% (158 of 354) of the cementless THAs performed during that time, and cementless THAs represented 34% (354 of 1038) of the THA practice during that period. No patient enrolled in this study was lost to followup. Multivariate survivorship analysis using Cox's regression model was performed with an endpoint of aseptic loosening of the femoral component. Loosening was defined according to the criteria described by Engh et al. and assessed by two independent observers. Patients with a diagnosis of prosthetic joint infection were excluded. Receiver operating characteristic (ROC) curve analysis was used to evaluate diagnostic performance of axial stem migration 1, 2, 3, and 4 years postoperatively as a predictor of aseptic loosening. Survivorship of hips with high (≥ 2.7 mm) and low (< 2.7 mm) migration was compared using a competing-events analysis. Femoral components that had aseptic loosening develop showed greater mean distal migration at 24 months postoperatively than did components that remained well fixed throughout the surveillance period (4.2 mm ± 3.1 mm vs 0.8 mm ± 0.9 mm; mean difference, 3.4 mm, 95% CI, 2.5-4.4; p ≤ 0.001). Distal migration at 24 months postoperatively was a strong risk factor for aseptic loosening (hazard ratio, 1.98; 95% CI, 1.51-2.57; p < 0.001). The associated overall diagnostic performance of 2-year distal migration for predicting aseptic loosening was good (area under the ROC curve, 0.86; 95% CI, 0.72-1.00; p < 0.001). Sensitivity of early migration measurement was high for the prediction of aseptic loosening during the first decade after surgery but decreased markedly thereafter. Stems with large amounts of early migration (≥ 2.7 mm) had lower 18-year survivorship than did stems with little early migration (29% [95% CI, 0%-62%] versus 95% [95% CI, 90%-100%] p < 0.001). Early migration, as measured by EBRA-FCA at 2 years postoperatively, has good diagnostic capabilities for detection of uncemented femoral components at risk for aseptic loosening during the first and early second decades after surgery. However, there was no relationship between early migration patterns and aseptic loosening during the late second and third decades. EBRA-FCA can be used as a research tool to evaluate new cementless stems or in clinical practice to evaluate migration patterns in patients with painful femoral components. Level III, diagnostic study.

  10. Clinical results of Hi-tech Knee II total knee arthroplasty in patients with rheumatoid athritis: 5- to 12-year follow-up

    PubMed Central

    2012-01-01

    Background Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention, flat-on-flat surface component geometry, all-polyethylene patella, strong initial fixation by the center screw of the tibial base plate, 10 layers of titanium alloy fiber mesh, and direct compression molded ultra high molecular weight polyethylene (UHMWPE), is appropriate for TKA in the Japanese knee. The present study was performed to evaluate the clinical results of primary TKA in RA using the cementless Hi-Tech Knee II CR-type prosthesis. Materials and methods We performed 32 consecutive primary TKAs using cementless Hi-Tech Knee II CR-type prosthesis in 31 RA patients. The average follow-up period was 8 years 3 months. Clinical evaluations were performed according to the American Knee Society (KS) system, knee score, function score, radiographic evaluation, and complications. Results The mean postoperative maximum flexion angle was 115.6°, and the KS knee score and function score improved to 88 and 70 after surgery, respectively. Complications, such as infection, occurred in 1 patient and revision surgery was performed. There were no cases of loosening in this cohort, and prosthesis survival rate was 96.9% at 12 years postoperatively. Conclusion These results suggest that TKA using the cementless Hi-Tech Knee II CR-type prosthesis is a very effective form of treatment in RA patients at 5 to 12 years postoperatively. Further long-term follow-up studies are required to determine the ultimate utility of this type of prosthesis. PMID:22356935

  11. An update on the recent literature on sickle cell bone disease.

    PubMed

    Osunkwo, Ifeyinwa

    2013-12-01

    To summarize the findings of the recent publications on sickle cell bone disease (SBD). Individuals with sickle cell disease (SCD) are living longer and develop progressive organ damage including SBD with age. Recent studies suggest alternative radiological diagnostics such as ultrasound and scintigraphy can detect and differentiate between different forms of SBD. MRI with or without diffusion-weighted sequences remains the gold standard. Case reports of cranio-orofacial SBD highlight the rarity of this presentation. Vitamin D deficiency is highly prevalent at all ages, but may not be an independent risk factor for avascular necrosis (AVN). Gene polymorphisms of the Annexin A gene may predict AVN in SCD. A recent study demonstrated reduced days with pain and improved physical activity quality of life following high-dose vitamin D therapy. The high rates of osteopenia and osteoporosis in SCD support the need for research addressing this rising public health problem. Lastly, results of total hip arthroplasty for AVN in SCD has improved significantly over time with the use of cementless prosthetic material and improved supportive care. SBD remains poorly studied. Prospective randomized studies targeting predictors, diagnostics, prevention, and treatment options for SBD are sorely needed.

  12. A numerical model to reproduce squeaking of ceramic-on-ceramic total hip arthroplasty. Influence of design and material.

    PubMed

    Piriou, P; Ouenzerfi, G; Migaud, H; Renault, E; Massi, F; Serrault, M

    2016-06-01

    Modern ceramic (CoC) bearings for hip arthroplasty (THA) have been used in younger patients who expect improved survivorship. However, audible squeaking produced by the implant is an annoying complication. Previous numerical simulations were not able to accurately reproduce in vitro and in vivo observations. Therefore, we developed a finite element model to: (1) reproduce in vitro squeaking and validate the model by comparing it with in vivo recordings, (2) determine why there are differences between in vivo and in vitro squeaking frequencies, (3) identify the stem's role in this squeaking, (4) predict which designs and materials are more likely to produce squeaking. A CoC THA numerical model can be developed that reproduces the squeaking frequencies observed in vivo. Numerical methods (finite element analysis [ANSYS]) and experimental methods (using a non-lubricated simulated hip with a cementless 32mm CoC THA) were developed to reproduce squeaking. Numerical analysis was performed to identify the frequencies that cause vibrations perceived as an acoustic emission. The finite element analysis (FEA) model was enhanced by adjusting periprosthetic bone and soft tissue elements in order to reproduce the squeaking frequencies recorded in vivo. A numerical method (complex eigenvalue analysis) was used to find the acoustic frequencies of the squeaking noise. The frequencies obtained from the model and the hip simulator were compared to those recorded in vivo. The numerical results were validated by experiments with the laboratory hip simulator. The frequencies obtained (mean 2790Hz with FEA, 2755Hz with simulator, decreasing to 1759Hz when bone and soft tissue were included in the FEA) were consistent with those of squeaking hips recorded in vivo (1521Hz). The cup and ceramic insert were the source of the vibration, but had little influence on the diffusion of the noise required to make the squeaking audible to the human ear. The FEA showed that diffusion of squeaking was due to an unstable vibration of the stem during frictional contact. The FEA predicted a higher rate of squeaking (at a lower coefficient of friction) when TZMF™ alloy is used instead of Ti6Al4V and when an anatomic press-fit stem is used instead of straight self-locking designs. The current FEA model is reliable; it can be used to assess various stem designs and alloys to predict the different rates of squeaking that certain stems will likely produce. Level IV in vitro study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  13. Characterization of the fretting corrosion behavior, surface and debris from head-taper interface of two different modular hip prostheses.

    PubMed

    Dos Santos, Claudio T; Barbosa, Cassio; Monteiro, Maurício J; Abud, Ibrahim C; Caminha, Ieda M V; Roesler, Carlos R M

    2016-09-01

    Modular hip prostheses are flexible to match anatomical variations and to optimize mechanical and tribological properties of each part by using different materials. However, micromotions associated with the modular components can lead to fretting corrosion and, consequently, to release of debris which can cause adverse local tissue reactions in human body. In the present study, the surface damage and residues released during in vitro fretting corrosion tests were characterized by stereomicroscope, SEM and EDS. Two models of modular hip prosthesis were studied: Model SS/Ti Cementless whose stem was made of ASTM F136 Ti-6Al-4V alloy and whose metallic head was made of ASTM F138 austenitic stainless steel, and Model SS/SS Cemented with both components made of ASTM F138 stainless steel. The fretting corrosion tests were evaluated according to the criteria of ASTM F1875 standard. Micromotions during the test caused mechanical wear and material loss in the head-taper interface, resulting in fretting-corrosion. Model SS/SS showed higher grade of corrosion. Different morphologies of debris predominated in each model studied. Small and agglomerated particles were observed in the Model SS/Ti and irregular particles in the Model SS/SS. After 10 million cycles, the Model SS/Ti was more resistant to fretting corrosion than the Model SS/SS. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Comparison of cemented and uncemented fixation in total knee arthroplasty.

    PubMed

    Brown, Thomas E; Harper, Benjamin L; Bjorgul, Kristian

    2013-05-01

    As a result of reading this article, physicians should be able to :1. Understand the rationale behind using uncemented fixation in total knee arthroplasty.2.Discuss the current literature comparing cemented and uncemented total knee arthroplasty3. Describe the value of radiostereographic analysis in assessing implant stability.4. Appreciate the limitations in the available literature advocating 1 mode of fixation in total knee arthroplasty. Total knee arthroplasty performed worldwide uses either cemented, cementless, or hybrid (cementless femur with a cemented tibia) fixation of the components. No recent literature review concerning the outcomes of cemented vs noncemented components has been performed. Noncemented components offer the potential advantage of a biologic interface between the bone and implants, which could demonstrate the greatest advantage in long-term durable fixation in the follow-up of young patients undergoing arthroplasty. Several advances have been made in the backing of the tibial components that have not been available long enough to yield long-term comparative follow-up studies. Short-term radiostereographic analysis studies have yielded differing results. Although long-term, high-quality studies are still needed, material advances in biologic fixation surfaces, such as trabecular metal and hydroxyapatite, may offer promising results for young and active patients undergoing total knee arthroplasty when compared with traditional cemented options. Copyright 2013, SLACK Incorporated.

  15. A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.

    PubMed

    Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N

    2016-10-01

    The removal of well-fixed acetabular components following THA (total hip arthroplasty) is a difficult operation and could be accompanied by the loss of acetabular bone stock. The optimal method for fixation is still under debate. The aim of this pilot study was to compare the tear-out resistance and failure behavior between osseo-integrated and non-integrated screw cups. Furthermore, we examined whether there are differences in the properties mentioned between screw sockets and cemented polyethylene cups. Tear-out resistance and related mechanical work required for the tear-out of osseo-integrated screw sockets are higher than in non-integrated screw sockets. Ten human coxal bones from six cadavers with osseo-integrated screw sockets (n=4), non-integrated (implanted post-mortem, n=3) screw sockets and cemented polyethylene cups (n=3) were used for tear-out testing. The parameters axial failure load and mechanical work for tear-out were introduced as measures for determining the stability of acetabular components following THA. The osseo-integrated screw sockets yielded slightly higher tear-out resistance (1.61±0.26kN) and related mechanical work compared to the non-integrated screw sockets (1.23±0.39kN, P=0.4). The cemented polyethylene cups yielded the lowest tear-out resistance with a failure load of 1.18±0.24kN. Compared to the screw cups implanted while alive, they also differ on a non-significant level (P=0.1). Osseous failure patterns differed especially for the screw sockets compared to the cemented polyethylene cups. Osseo-integration did not greatly influence the tear-out stability in cementless screw sockets following axial loading. Furthermore, the strength of the bone-implant-interface of cementless screw sockets appears to be similar to cemented polyethylene cups. However, given the high failure load, high mechanical load and because of the related bone failure patterns, removal should not be performed by means of tear-out but rather by osteotomes or other curved cutting devices to preserve the acetabular bone stock. Level III, case-control-study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. [Tribological properties of carbon fiber-reinforced plastic. Experimental and clinical results].

    PubMed

    Früh, H J; Ascherl, R; Hipp, E

    1997-02-01

    Wear of the articulating components (especially PE-UHMW) of total hip endoprostheses is the most important technical factor limiting the functional lifetime. To minimize wear debris, ceramic heads, according to ISO 6474 (Al2O3), have been used, from 1969 paired with Al2O3 and since 1975 paired with PE-UHMW. Al2O3 balls articulating with cups made from CFRP have been in clinical use since 1988. Laboratory experiments and in-vivo testing showed minimized wear debris and mild biological response to wear products using CFRP (carbon fiber reinforced plastic) instead of PE-UHMW as the cup material. The articulating surfaces of retrieved ceramic heads (Al2O3-Biolox) and cementless CFRP cups (carbon fiber reinforced plastic, Caproman) were compared using sphericity measurement techniques, scanning electron microscopy (SEM) and roughness measurements (including advanced roughness parameters Rvk or Rpk according to ISO 4287). Altogether, the first results of the clinical study showed that the combination Al2O3-ball/CFRP-cup came up to the expected lower wear rates compared with the conventional combinations. The wear rates are comparable with the combination Al2O3/Al2O3 without the material-related problems of ceramic components in all ceramic combinations.

  17. Small and similar amounts of micromotion in an anatomical stem and a customized cementless femoral stem in regular-shaped femurs. A 5-year follow-up randomized RSA study.

    PubMed

    Nysted, Mona; Foss, Olav A; Klaksvik, Jomar; Benum, Pål; Haugan, Kristin; Husby, Otto Schnell; Aamodt, Arild

    2014-04-01

    High primary stability is important for long-term survival of uncemented femoral stems. Different stem designs are currently in use. The ABG-I is a well-documented anatomical stem with a press-fit design. The Unique stem is designed for a tight customized fit to the cortical bone of the upper femur. This implant was initially developed for patients with abnormal anatomy, but the concept can also be used in patients with normal femoral anatomy. We present 5-year radiostereometric analysis (RSA) results from a randomized study comparing the ABG-I anatomical stem with the Unique femoral stem. 100 hips with regular upper femur anatomy were randomized to either the ABG-I stem or the Unique femoral stem. RSA measurements were performed postoperatively and after 3, 6, 12, 24, and 60 months. RSA measurements from 80 hips were available for analysis at the 5-year follow-up. Small amounts of movement were observed for both stems, with no statistically significant differences between the 2 types. No improvement in long-term stability was found from using a customized stem design. However, no patients with abnormal geometry of the upper femur were included in this study.

  18. Cementless total knee arthroplasty

    PubMed Central

    Risitano, Salvatore; Sabatini, Luigi; Giachino, Matteo; Agati, Gabriele; Massè, Alessandro

    2016-01-01

    Interest for uncemented total knee arthroplasty (TKA) has greatly increased in recent years. This technique, less used than cemented knee replacement in the last decades, sees a revival thanks an advance in prosthetic design, instrumentation and operative technique. The related literature in some cases shows conflicting data on survival and on the revision’s rate, but in most cases a success rate comparable to cemented TKA is reported. The optimal fixation in TKA is a subject of debate with the majority of surgeons favouring cemented fixation. PMID:27162779

  19. Efficacy of Oral Etidronate for Skeletal Diseases in Japan

    PubMed Central

    Takeda, Tsuyoshi; Sato, Yoshihiro

    2005-01-01

    Etidronate is an oral bisphosphonate compound that is known to reduce bone resorption through the inhibition of osteoclastic activity. The efficacy of etidronate for involutional (postmenopausal and senile) and glucocorticoid-induced osteoporosis, as well as that for other skeletal diseases, was reviewed in Japanese patients. Cyclical etidronate treatment (200 mg or 400 mg/day for 2 weeks about every 3 months) increases the lumbar bone mineral density (BMD) in patients with involutional osteoporosis and prevents incident vertebral fractures in patients with glucocorticoid-induced osteoporosis. The losses of the lumbar BMD in patients with liver cirrhosis and the metacarpal BMD in hemiplegic patients after stroke are prevented, and the lumbar BMD is possibly increased, preventing fragile fractures in adult patients with osteogenesis imperfecta type I. Furthermore, proximal bone resorption around the femoral stem is reduced and some complications may be prevented in patients who undergo cementless total hip arthroplasty. Oral etidronate treatment may also help to transiently relieve metastatic cancer bone pain followed by a decrease in abnormally raised bone resorption in patients with painful bone metastases from primary cancer sites, such as the lung, breast and prostate. Thus, oral etidronate treatment is suggested to be efficacious for osteoporosis, as well as other skeletal diseases associated with increased bone resorption, in Japanese patients. Randomized controlled trials needed to be conducted on a large number of patients to confirm these effects. PMID:15988801

  20. Subsequent Total Joint Arthroplasty After Primary Total Knee or Hip Arthroplasty

    PubMed Central

    Sanders, Thomas L.; Maradit Kremers, Hilal; Schleck, Cathy D.; Larson, Dirk R.; Berry, Daniel J.

    2017-01-01

    Background: Despite the large increase in total hip arthroplasties and total knee arthroplasties, the incidence and prevalence of additional contralateral or ipsilateral joint arthroplasty are poorly understood. The purpose of this study was to determine the rate of additional joint arthroplasty after a primary total hip arthroplasty or total knee arthroplasty. Methods: This historical cohort study identified population-based cohorts of patients who underwent primary total hip arthroplasty (n = 1,933) or total knee arthroplasty (n = 2,139) between 1969 and 2008. Patients underwent passive follow-up through their medical records beginning with the primary total hip arthroplasty or total knee arthroplasty. We assessed the likelihood of undergoing a subsequent total joint arthroplasty, including simultaneous and staged bilateral procedures. Age, sex, and calendar year were evaluated as potential predictors of subsequent arthroplasty. Results: During a mean follow-up of 12 years after an initial total hip arthroplasty, we observed 422 contralateral total hip arthroplasties (29% at 20 years), 76 contralateral total knee arthroplasties (6% at 10 years), and 32 ipsilateral total knee arthroplasties (2% at 20 years). Younger age was a significant predictor of contralateral total hip arthroplasty (p < 0.0001), but not a predictor of the subsequent risk of total knee arthroplasty. During a mean follow-up of 11 years after an initial total knee arthroplasty, we observed 809 contralateral total knee arthroplasties (45% at 20 years), 31 contralateral total hip arthroplasties (3% at 20 years), and 29 ipsilateral total hip arthroplasties (2% at 20 years). Older age was a significant predictor of ipsilateral or contralateral total hip arthroplasty (p < 0.001). Conclusions: Patients undergoing total hip arthroplasty or total knee arthroplasty can be informed of a 30% to 45% chance of a surgical procedure in a contralateral cognate joint and about a 5% chance of a surgical procedure in noncognate joints within 20 years of initial arthroplasty. Increased risk of contralateral total knee arthroplasty following an initial total hip arthroplasty may be due to gait changes prior to and/or following total hip arthroplasty. The higher prevalence of bilateral total hip arthroplasty in younger patients may result from bilateral disease processes that selectively affect the young hip, such as osteonecrosis, or structural hip problems, such as acetabular dysplasia or femoroacetabular impingement. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. PMID:28244910

  1. Hip joint replacement

    MedlinePlus

    ... Total hip replacement; Hip hemiarthroplasty; Arthritis - hip replacement; Osteoarthritis - hip replacement ... total hip replacement surgery in patients with hip osteoarthritis: a long-term follow-up of a randomised ...

  2. Finite element modelling of primary hip stem stability: the effect of interference fit.

    PubMed

    Abdul-Kadir, Mohammed Rafiq; Hansen, Ulrich; Klabunde, Ralf; Lucas, Duncan; Amis, Andrew

    2008-01-01

    The most commonly reported complications related to cementless hip stems are loosening and thigh pain; both of these have been attributed to high levels of relative micromotion at the bone-implant interface due to insufficient primary fixation. Primary fixation is believed by many to rely on achieving a sufficient interference fit between the implant and the bone. However, attempting to achieve a high interference fit not infrequently leads to femoral canal fracture either intra-operatively or soon after. The appropriate range of diametrical interference fit that ensures primary stability without risking femoral fracture is not well understood. In this study, a finite element model was constructed to predict micromotion and, therefore, instability of femoral stems. The model was correlated with an in vitro micromotion experiment carried out on four cadaver femurs. It was confirmed that interference fit has a very significant effect on micromotion and ignoring this parameter in an analysis of primary stability is likely to underestimate the stability of the stem. Furthermore, it was predicted that the optimal level of interference fit is around 50 microm as this is sufficient to achieve good primary fixation while having a safety factor of 2 against femoral canal fracture. This result is of clinical relevance as it indicates a recommendation for the surgeon to err on the side of a low interference fit rather than risking femoral fracture.

  3. A biomechanical testing system to determine micromotion between hip implant and femur accounting for deformation of the hip implant: Assessment of the influence of rigid body assumptions on micromotions measurements.

    PubMed

    Leuridan, Steven; Goossens, Quentin; Roosen, Jorg; Pastrav, Leonard; Denis, Kathleen; Mulier, Michiel; Desmet, Wim; Vander Sloten, Jos

    2017-02-01

    Accurate pre-clinical evaluation of the initial stability of new cementless hip stems using in vitro micromotion measurements is an important step in the design process to assess the new stem's potential. Several measuring systems, linear variable displacement transducer-based and other, require assuming bone or implant to be rigid to obtain micromotion values or to calculate derived quantities such as relative implant tilting. An alternative linear variable displacement transducer-based measuring system not requiring a rigid body assumption was developed in this study. The system combined advantages of local unidirectional and frame-and-bracket micromotion measuring concepts. The influence and possible errors that would be made by adopting a rigid body assumption were quantified. Furthermore, as the system allowed emulating local unidirectional and frame-and-bracket systems, the influence of adopting rigid body assumptions were also analyzed for both concepts. Synthetic and embalmed bone models were tested in combination with primary and revision implants. Single-legged stance phase loading was applied to the implant - bone constructs. Adopting a rigid body assumption resulted in an overestimation of mediolateral micromotion of up to 49.7μm at more distal measuring locations. Maximal average relative rotational motion was overestimated by 0.12° around the anteroposterior axis. Frontal and sagittal tilting calculations based on a unidirectional measuring concept underestimated the true tilting by an order of magnitude. Non-rigid behavior is a factor that should not be dismissed in micromotion stability evaluations of primary and revision femoral implants. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. In vivo measured joint friction in hip implants during walking after a short rest.

    PubMed

    Damm, Philipp; Bender, Alwina; Duda, Georg; Bergmann, Georg

    2017-01-01

    It has been suspected that friction in hip implants is higher when walking is initiated after a resting period than during continuous movement. It cannot be excluded that such increased initial moments endanger the cup fixation in the acetabulum, overstress the taper connections in the implant or increase wear. To assess these risks, the contact forces, friction moments and friction coefficients in the joint were measured in vivo in ten subjects. Instrumented hip joint implants with telemetric data transmission were used to access the contact loads between the cup and head during the first steps of walking after a short rest. The analysis demonstrated that the contact force is not increased during the first step. The friction moment in the joint, however, is much higher during the first step than during continuous walking. The moment increases throughout the gait cycle were 32% to 143% on average and up to 621% individually. The high initial moments will probably not increase wear by much in the joint. However, comparisons with literature data on the fixation resistance of the cup against moments made clear that the stability can be endangered. This risk is highest during the first postoperative months for cementless cups with insufficient under-reaming. The high moments after a break can also put taper connections between the head and neck and neck and shaft at a higher risk. During continuous walking, the friction moments individually were extremely varied by factors of 4 to 10. Much of this difference is presumably caused by the varying lubrication properties of the synovia. These large moment variations can possibly lead to friction-induced temperature increases during walking, which are higher than the 43.1°C which have previously been observed in a group of only five subjects.

  5. Mortality rates at 10 years after metal-on-metal hip resurfacing compared with total hip replacement in England: retrospective cohort analysis of hospital episode statistics

    PubMed Central

    Kendal, Adrian R; Prieto-Alhambra, Daniel; Arden, Nigel K; Judge, Andrew

    2013-01-01

    Objectives To compare 10 year mortality rates among patients undergoing metal-on-metal hip resurfacing and total hip replacement in England. Design Retrospective cohort study. Setting English hospital episode statistics database linked to mortality records from the Office for National Statistics. Population All adults who underwent primary elective hip replacement for osteoarthritis from April 1999 to March 2012. The exposure of interest was prosthesis type: cemented total hip replacement, uncemented total hip replacement, and metal-on-metal hip resurfacing. Confounding variables included age, sex, Charlson comorbidity index, rurality, area deprivation, surgical volume, and year of operation. Main outcome measures All cause mortality. Propensity score matching was used to minimise confounding by indication. Kaplan-Meier plots estimated the probability of survival up to 10 years after surgery. Multilevel Cox regression modelling, stratified on matched sets, described the association between prosthesis type and time to death, accounting for variation across hospital trusts. Results 7437 patients undergoing metal-on-metal hip resurfacing were matched to 22 311 undergoing cemented total hip replacement; 8101 patients undergoing metal-on-metal hip resurfacing were matched to 24 303 undergoing uncemented total hip replacement. 10 year rates of cumulative mortality were 271 (3.6%) for metal-on-metal hip resurfacing versus 1363 (6.1%) for cemented total hip replacement, and 239 (3.0%) for metal-on-metal hip resurfacing versus 999 (4.1%) for uncemented total hip replacement. Patients undergoing metal-on-metal hip resurfacing had an increased survival probability (hazard ratio 0.51 (95% confidence interval 0.45 to 0.59) for cemented hip replacement; 0.55 (0.47 to 0.65) for uncemented hip replacement). There was no evidence for an interaction with age or sex. Conclusions Patients with hip osteoarthritis undergoing metal-on-metal hip resurfacing have reduced mortality in the long term compared with those undergoing cemented or uncemented total hip replacement. This difference persisted after extensive adjustment for confounding factors available in our data. The study results can be applied to matched populations, which exclude patients who are very old and have had complex total hip replacements. Although residual confounding is possible, the observed effect size is large. These findings require validation in external cohorts and randomised clinical trials. PMID:24284336

  6. Cementless Oxford medial unicompartimental knee replacement: an independent series with a 5-year-follow-up.

    PubMed

    Panzram, Benjamin; Bertlich, Ines; Reiner, Tobias; Walker, Tilman; Hagmann, Sébastien; Gotterbarm, Tobias

    2017-07-01

    Cemented unicompartmental knee replacement (UKR) has proven excellent long-term survival rates and functional scores in Price et al. (Clin Orthop Relat Res 435:171-180, 2005), Price and Svard (Clin Orthop Relat Res 469(1):174-179, 2011) and Murray et al. (Bone Joint Surg Br 80(6):983-989, 1998). The main causes for revision, aseptic loosening and pain of unknown origin might be addressed by cementless UKR in Liddle et al. (Bone Joint J 95-B(2):181-187, 2013), Pandit et al. (J Bone Joint Surg Am 95(15):1365-1372, 2013), National Joint Registry for England, Wales and Northern Ireland: 10th Annual Report 2013 ( http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/10th_annual_report/NJR%2010th%20Annual%20Report%202013%20B.pdf , 2013), Swedish Knee Arthroplasty Register: Annual Report 2013 ( http://www.myknee.se/pdf/SKAR2013_Eng.pdf , 2013). This single-centre retrospective cohort study reports the 5-year follow-up results of our first 30 consecutively implanted cementless Oxford UKR (OUKR). Clinical outcome was measured using the OKS, AKSS, range of movement and level of pain (visual analogue scale). The results were compared to cemented OUKR in a matched-pair analysis. Implant survival was 89.7%. One revision each was performed due to tibial fracture, progression of osteoarthritis (OA) and inlay dislocation. The 5-year survival rate of the cementless group was 89.7% and of the cemented group 94.1%. Both groups showed excellent postoperative clinical scores. Cementless fixation shows good survival rates and clinical outcome compared to cemented fixation.

  7. Bony integration of titanium implants with a novel bioactive calcium titanate (Ca4Ti3O10) surface treatment in a rabbit model.

    PubMed

    Haenle, Maximilian; Lindner, Tobias; Ellenrieder, Martin; Willfahrt, Manfred; Schell, Hanna; Mittelmeier, Wolfram; Bader, Rainer

    2012-10-01

    Nowadays total joint replacement is an indispensable component of modern medicine. The surfaces characteristics of cementless prostheses may be altered to achieve an accelerated and enduring bony integration. Classic surface coatings bear the risk of loosening or flaking from the implant body. This risk is excluded by the chemical conversion of the naturally existing TiO(2) surface layer into calcium titanate. The aim of this experimental animal study was to investigate the bony integration of implants with a new calcium titanate surface (Ca(4)Ti(3)O(10)) compared with a conventional standard Ti6Al4V surface. Cylindrical implants, made of titanium alloy (Ti6Al4V) were implanted in both lateral femoral condyles of New Zealand white rabbits. In each animal, an implant with and without surface treatment was inserted in a blinded manner. Animals were sacrificed after 4, 12, and 36 weeks, respectively. The axial pull-off forces were determined for 25 animals using a universal testing machine (Zwick Z010, Ulm, Germany). Furthermore, a histological analysis of the bony integration of the implants was performed in 12 specimens. In general, the pull-off forces for untreated and treated implants increased with longer survival times of the rabbits. No significant difference could be shown after 4 weeks between treated and untreated implants. After 12 weeks, the treated implants revealed a statistical significant higher pull-off force. After 36 weeks, the pull-off forces for treated and untreated implants aligned again. Titanium implants treated with calcium titanate, may offer an interesting and promising implant surface modification for endoprosthetic implants. They might lead to an accelerated osseointegration of total hip and knee replacements. Copyright © 2012 Wiley Periodicals, Inc.

  8. Hip contact forces in asymptomatic total hip replacement patients differ from normal healthy individuals: Implications for preclinical testing.

    PubMed

    Li, Junyan; Redmond, Anthony C; Jin, Zhongmin; Fisher, John; Stone, Martin H; Stewart, Todd D

    2014-08-01

    Preclinical durability testing of hip replacement implants is standardised by ISO-14242-1 (2002) which is based on historical inverse dynamics analysis using data obtained from a small sample of normal healthy individuals. It has not been established whether loading cycles derived from normal healthy individuals are representative of loading cycles occurring in patients following total hip replacement. Hip joint kinematics and hip contact forces derived from multibody modelling of forces during normal walking were obtained for 15 asymptomatic total hip replacement patients and compared to 38 normal healthy individuals and to the ISO standard for pre-clinical testing. Hip kinematics in the total hip replacement patients were comparable to the ISO data and the hip contact force in the normal healthy group was also comparable to the ISO cycles. Hip contact forces derived from the asymptomatic total hip replacement patients were comparable for the first part of the stance period but exhibited 30% lower peak loads at toe-off. Although the ISO standard provides a representative kinematic cycle, the findings call into question whether the hip joint contact forces in the ISO standard are representative of those occurring in the joint following total hip replacement. Copyright © 2014. Published by Elsevier Ltd.

  9. Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking.

    PubMed

    Li, Junyan; McWilliams, Anthony B; Jin, Zhongmin; Fisher, John; Stone, Martin H; Redmond, Anthony C; Stewart, Todd D

    2015-06-01

    Symptomatic leg length inequality accounts for 8.7% of total hip replacement related claims made against the UK National Health Service Litigation authority. It has not been established whether symptomatic leg length inequality patients following total hip replacement have abnormal hip kinetics during gait. Hip kinetics in 15 unilateral total hip replacement patients with symptomatic leg length inequality during gait was determined through multibody dynamics and compared to 15 native hip healthy controls and 15 'successful' asymptomatic unilateral total hip replacement patients. More significant differences from normal were found in symptomatic leg length inequality patients than in asymptomatic total hip replacement patients. The leg length inequality patients had altered functions defined by lower gait velocity, reduced stride length, reduced ground reaction force, decreased hip range of motion, reduced hip moment and less dynamic hip force with a 24% lower heel-strike peak, 66% higher mid-stance trough and 37% lower toe-off peak. Greater asymmetry in hip contact force was also observed in leg length inequality patients. These gait adaptions may affect the function of the implant and other healthy joints in symptomatic leg length inequality patients. This study provides important information for the musculoskeletal function and rehabilitation of symptomatic leg length inequality patients. Copyright © 2015. Published by Elsevier Ltd.

  10. Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: an in-vitro model.

    PubMed

    Norman, T L; Ackerman, E S; Smith, T S; Gruen, T A; Yates, A J; Blaha, J D; Kish, V L

    2006-02-01

    Cementless total hip femoral components rely on press-fit for initial stability and bone healing and remodeling for secondary fixation. However, the determinants of satisfactory press-fit are not well understood. In previous studies, human cortical bone loaded circumferentially to simulate press-fit exhibited viscoelastic, or time dependent, behavior. The effect of bone viscoelastic behavior on the initial stability of press-fit stems is not known. Therefore, in the current study, push-out loads of cylindrical stems press-fit into reamed cadaver diaphyseal femoral specimens were measured immediately after assembly and 24 h with stem-bone diametral interference and stem surface treatment as independent variables. It was hypothesized that stem-bone interference would result in a viscoelastic response of bone that would decrease push-out load thereby impairing initial press-fit stability. Results showed that push-out load significantly decreased over a 24 h period due to bone viscoelasticity. It was also found that high and low push-out loads occurred at relatively small amounts of stem-bone interference, but a relationship between stem-bone interference and push-out load could not be determined due to variability among specimens. On the basis of this model, it was concluded that press-fit fixation can occur at relatively low levels of diametral interference and that stem-bone interference elicits viscoelastic response that reduces stem stability over time. From a clinical perspective, these results suggest that there could be large variations in initial press-fit fixation among patients.

  11. Revision total hip arthroplasty due to pain from hypersensitivity to cobalt-chromium in total hip arthroplasty.

    PubMed

    Kosukegawa, Ima; Nagoya, Satoshi; Kaya, Mitsunori; Sasaki, Koichi; Sasaki, Mikito; Yamashita, Toshihiko

    2011-09-01

    We report a case with hypersensitivity to CoCr in total hip arthroplasty coupled with conventional polyethylene and CoCr femoral head. The patient complained of left hip pain and systemic fever, and computed tomography imaging revealed a periprosthetic cystic lesion, so we performed revision total hip arthroplasty using a titanium stem and ceramic head and highly crosslinked polyethylene. Hip pain and cystic lesion disappeared 3 years after revision surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Physical activity of elderly patients after total hip arthroplasty.

    PubMed

    Cukras, Zbigniew; Praczko, Katarzyna; Kostka, Tomasz; Jegier, Anna

    2007-01-01

    Total hip arthroplasty (THA) is the most common method of treatment of severe hip osteoarthritis. There is little data concerning the physical activity of total hip arthroplasty patients in Poland and investigations to explore this area are useful. The aim of the study was to describe the post-operative physical activity of total hip arthroplasty patients. A total of 146 adult people were examined, among which 28 men and 41 women had undergone total hip arthroplasty due to primary osteoarthritis of the hip, while another 32 men and 41 women matched for age who had not undergone hip surgery for osteoarthritis served as controls. The physical activity of study participants was assessed with the 7-Day Physical Activity Recall Questionnaire. All participants were also asked about the type and amount of physical activity they engaged in to maintain good health. Physical activity measured as the total amount of calories expended through physical activity per week was similar in the post-THA patients compared to the controls. The only differences were a smaller amount of calories expended during low-intensity physical activity by men after total hip arthroplasty compared to men who had not undergone surgery for osteoarthritis and a smaller amount of calories expended through high-intensity physical activity by women after total hip arthroplasty compared to female controls. The kinds of recreational physical activity most commonly practised by patients a mean of two years after total hip arthroplasty were marching, bicycling and general body conditioning exercises (usually the continuation of exercises recommended during post-operative rehabilitation). The percentage of post-THA patients undertaking physical activity for the prevention of non-communicable diseases was low. Physical activity should be more effectively encouraged in patients after total hip arthroplasty.

  13. Total hip arthroplasty of dysplastic hip after previous Chiari pelvic osteotomy.

    PubMed

    Minoda, Yukihide; Kadowaki, Toru; Kim, Mitsunari

    2006-08-01

    Many reports have suggested that Chiari pelvic osteotomy would improve the results of acetabular component placement and fixation in subsequent total hip arthroplasty. However, little is known concerning the biomechanical, radiological, and clinical effects of Chiari pelvic osteotomy on subsequent total hip arthroplasty. Ten total hip arthroplasties for developmental dysplasia of the hip after previous Chiari pelvic osteotomy (Chiari group) were compared with 20 total hip arthroplasties for developmental dysplasia of the hip without previous surgery (control group). Preoperative patient demographic data and operative technique were well matched between the groups. The mean duration of follow-up was 3.0 years. Biomechanical, radiological, and clinical evaluations were performed. No acetabular or femoral components exhibited loosening. All patients had good or excellent clinical score according to the Merle d'Aubigne-Postel rating system at the most recent follow-up. Abductor force and joint force were smaller in the Chiari group, although long operative time, more blood loss, and verticalization of joint force were noted in this group. This limited study suggested that Chiari pelvic osteotomy changed the biomechanical features of the hip joint, and that this alteration might have compromised subsequent total hip arthroplasty.

  14. Muscle strength and areal bone mineral density at the hip in women: a cross-sectional study.

    PubMed

    Pasco, Julie A; Holloway, Kara L; Brennan-Olsen, Sharon L; Moloney, David J; Kotowicz, Mark A

    2015-05-24

    Muscle strengthening exercises are promoted for building and maintaining a healthy skeleton. We aimed to investigate the relationship between muscle strength and areal bone mineral density (BMD) at the hip in women aged 26-97 years. This cross-sectional study utilises data from 863 women assessed for the Geelong Osteoporosis Study. Measures of hip flexor and abductor strength were made using a hand-held dynamometer (Nicholas Manual Muscle Tester). The maximal measure from three trials on each leg was used for analyses. BMD was measured at the hip using dual energy x-ray absorptiometry (DXA; Lunar DPX-L). Total lean mass, body fat mass and appendicular lean mass were determined from whole body DXA scans. Linear regression techniques were used with muscle strength as the independent variable and BMD as the dependent variable. Models were adjusted for age and indices of body composition. Measures of age-adjusted hip flexor strength and hip abductor strength were positively associated with total hip BMD. For each standard deviation (SD) increase in hip flexor strength, the increase in mean total hip BMD (SD) was 10.4 % (p = 0.009). A similar pattern was observed for hip abductor strength, with an increase in mean total hip BMD of 22.8 % (p = 0.025). All associations between hip muscle strength and total hip BMD were independent of height, but were nullified after adjusting for appendicular lean mass or total lean mass. There was a positive association observed between muscle strength and BMD at the hip. However, this association was explained by measures of lean mass.

  15. Tendon Disorders After Total Hip Arthroplasty: Evaluation and Management.

    PubMed

    Capogna, Brian M; Shenoy, Kartik; Youm, Thomas; Stuchin, Steven A

    2017-10-01

    Most patients who undergo total hip arthroplasty are very satisfied with their outcomes. However, there is a small subset of patients who have persistent pain after surgery. The etiology of pain after total hip arthroplasty varies widely; however, tendon disorders are a major cause of debilitating pain that often go unrecognized. We performed a literature review to identify the most common tendon pathologies after total hip arthroplasty which include iliopsoas tendinitis, greater trochanteric pain syndrome, snapping hip syndrome, and abductor tendinopathy. We present a simplified approach highlighting the presentation and management of patients with suspected tendinopathies after total hip arthroplasty. These tendinopathies are treatable, and management begins with nonoperative modalities; however, in cases not responsive to conservative management, operative intervention may be necessary. Tendinopathies after total hip arthroplasty sometimes go unrecognized but when treated can result in higher surgeon and patient satisfaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Genetic evaluation of the total hip score of four populous breeds of dog, as recorded by the New Zealand Veterinary Association Hip Dysplasia Scheme (1991-2011).

    PubMed

    Soo, M; Sneddon, N W; Lopez-Villalobos, N; Worth, A J

    2015-03-01

    To use estimated breeding value (EBV) analysis to investigate the genetic trend of the total hip score (to assess canine hip dysplasia) in four populous breeds of dogs using the records from the New Zealand Veterinary Association (NZVA) Canine Hip Dysplasia Scheme database (1991 to 2011). Estimates of heritability and EBV for the NZVA total hip score of individual dogs from the German Shepherd, Labrador Retriever, Golden Retriever and Rottweiler breeds were obtained using restricted maximum likelihood procedures with a within-breed linear animal model. The model included the fixed effects of gender, birth year, birth season, age at scoring and the random effect of animal. The pedigree file included animals recorded between 1990 and 2011. A total of 2,983 NZVA hip score records, from a pedigree of 3,172 animals, were available for genetic evaluation. Genetic trends of the NZVA total hip score were calculated as the regression coefficient of the EBV (weighted by reliabilities) on year of birth. The estimates of heritability for hip score were 0.32 (SE 0.08) in German Shepherd, 0.37 (SE 0.08) in Labrador Retriever, 0.29 (SE 0.08) in Golden Retriever and 0.52 (SE 0.18) in Rottweiler breeds. Genetic trend analysis revealed that only the German Shepherd breed exhibited a genetic trend towards better hip conformation over time, with a decline of 0.13 (SE 0.04) NZVA total hip score units per year (p<0.001). The genetic trends of total hip score for the remaining three breeds were not significantly different from zero (p>0.1). Despite moderate heritability of the NZVA total hip score, there has not been substantial improvement of this trait for the four breeds analysed in the study period. Greater improvement in reducing the prevalence of canine hip dysplasia may be possible if screening were to be compulsory as a requirement for registration of pedigree breeding stock, greater selection pressure were to be applied and selection of breeding stock made on the basis on an individual's EBV rather than the NZVA total hip score alone.

  17. Survey of patient-oriented total hip replacement information on the World Wide Web.

    PubMed

    Mabrey, J D

    2000-12-01

    The author conducted an informal survey of materials relating to diseases of the hip and total hip replacement as they appeared on the World Wide Web. The results varied depending on the key words used: hip and replacement yielded 1,818 matches; total hip replacement yielded 1,740 matches; hip replacement yielded 4,565 sites; and hip surgery yielded 1,073 sites. The number of sites for total hip replacement was observed to increase with time, having found an additional 30 sites from an identical search performed only 6 weeks earlier. The nature and quality of these sites varied from well-organized and informative, to personal testaments, to obvious commercial endeavors. Overall, this survey found an abundance of material regarding the hip and hip replacements on the World Wide Web, but orthopaedic societies need to take a more active role in constructing, maintaining, and monitoring these sites to best serve the needs of their patients and their members.

  18. Prevalence of Total Hip and Knee Replacement in the United States.

    PubMed

    Maradit Kremers, Hilal; Larson, Dirk R; Crowson, Cynthia S; Kremers, Walter K; Washington, Raynard E; Steiner, Claudia A; Jiranek, William A; Berry, Daniel J

    2015-09-02

    Descriptive epidemiology of total joint replacement procedures is limited to annual procedure volumes (incidence). The prevalence of the growing number of individuals living with a total hip or total knee replacement is currently unknown. Our objective was to estimate the prevalence of total hip and total knee replacement in the United States. Prevalence was estimated using the counting method by combining historical incidence data from the National Hospital Discharge Survey and the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases from 1969 to 2010 with general population census and mortality counts. We accounted for relative differences in mortality rates between those who have had total hip or knee replacement and the general population. The 2010 prevalence of total hip and total knee replacement in the total U.S. population was 0.83% and 1.52%, respectively. Prevalence was higher among women than among men and increased with age, reaching 5.26% for total hip replacement and 10.38% for total knee replacement at eighty years. These estimates corresponded to 2.5 million individuals (1.4 million women and 1.1 million men) with total hip replacement and 4.7 million individuals (3.0 million women and 1.7 million men) with total knee replacement in 2010. Secular trends indicated a substantial rise in prevalence over time and a shift to younger ages. Around 7 million Americans are living with a hip or knee replacement, and consequently, in most cases, are mobile, despite advanced arthritis. These numbers underscore the substantial public health impact of total hip and knee arthroplasties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  19. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  20. Subject specific finite element modeling of periprosthetic femoral fracture using element deactivation to simulate bone failure.

    PubMed

    Miles, Brad; Kolos, Elizabeth; Walter, William L; Appleyard, Richard; Shi, Angela; Li, Qing; Ruys, Andrew J

    2015-06-01

    Subject-specific finite element (FE) modeling methodology could predict peri-prosthetic femoral fracture (PFF) for cementless hip arthoplasty in the early postoperative period. This study develops methodology for subject-specific finite element modeling by using the element deactivation technique to simulate bone failure and validate with experimental testing, thereby predicting peri-prosthetic femoral fracture in the early postoperative period. Material assignments for biphasic and triphasic models were undertaken. Failure modeling with the element deactivation feature available in ABAQUS 6.9 was used to simulate a crack initiation and propagation in the bony tissue based upon a threshold of fracture strain. The crack mode for the biphasic models was very similar to the experimental testing crack mode, with a similar shape and path of the crack. The fracture load is sensitive to the friction coefficient at the implant-bony interface. The development of a novel technique to simulate bone failure by element deactivation of subject-specific finite element models could aid prediction of fracture load in addition to fracture risk characterization for PFF. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Single-dose radiation therapy for prevention of heterotopic ossification after total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Healy, W.L.; Lo, T.C.; Covall, D.J.

    1990-12-01

    Single-dose radiation therapy was prospectively evaluated for its efficacy in prevention of heterotopic ossification in patients at high risk after total hip arthroplasty. Thirty-one patients (34 hips) were treated between 1981 and 1988. Risk factors for inclusion in the protocol included prior evidence of heterotopic ossification, ankylosing spondylitis, and diffuse idiopathic skeletal hyperostosis. Patients with hypertrophic osteoarthritis or traumatic arthritis with osteophytes were not included. Operations on 34 hips included 19 primary total and 11 revision total hip arthroplasties and 4 excisions of heterotopic ossification. All patients received radiotherapy to the hip after operation with a single dose of 700more » centigray. Radiotherapy is recommended on the first postoperative day. After this single-dose radiation treatment, no patient had clinically significant heterotopic ossification. Recurrent disease developed in two hips (6%), as seen on radiography (grades 2 and 3). This series documents a 100% clinical success rate and a 94% radiographic success rate in preventing heterotopic ossification in patients at high risk after total hip arthroplasty. Single-dose radiotherapy is as effective as other radiation protocols in preventing heterotopic ossification after total hip arthroplasty. It is less expensive and easier to administer than multidose radiotherapy.« less

  2. In vivo measured joint friction in hip implants during walking after a short rest

    PubMed Central

    Damm, Philipp; Bender, Alwina; Duda, Georg; Bergmann, Georg

    2017-01-01

    Introduction It has been suspected that friction in hip implants is higher when walking is initiated after a resting period than during continuous movement. It cannot be excluded that such increased initial moments endanger the cup fixation in the acetabulum, overstress the taper connections in the implant or increase wear. To assess these risks, the contact forces, friction moments and friction coefficients in the joint were measured in vivo in ten subjects. Instrumented hip joint implants with telemetric data transmission were used to access the contact loads between the cup and head during the first steps of walking after a short rest. Results The analysis demonstrated that the contact force is not increased during the first step. The friction moment in the joint, however, is much higher during the first step than during continuous walking. The moment increases throughout the gait cycle were 32% to 143% on average and up to 621% individually. The high initial moments will probably not increase wear by much in the joint. However, comparisons with literature data on the fixation resistance of the cup against moments made clear that the stability can be endangered. This risk is highest during the first postoperative months for cementless cups with insufficient under-reaming. The high moments after a break can also put taper connections between the head and neck and neck and shaft at a higher risk. Discussion During continuous walking, the friction moments individually were extremely varied by factors of 4 to 10. Much of this difference is presumably caused by the varying lubrication properties of the synovia. These large moment variations can possibly lead to friction-induced temperature increases during walking, which are higher than the 43.1°C which have previously been observed in a group of only five subjects. PMID:28350858

  3. Unipedal standing exercise and hip bone mineral density in postmenopausal women: a randomized controlled trial.

    PubMed

    Sakai, Akinori; Oshige, Toshihisa; Zenke, Yukichi; Yamanaka, Yoshiaki; Nagaishi, Hitoshi; Nakamura, Toshitaka

    2010-01-01

    The aim of this study was to test the effect of unipedal standing exercise on bone mineral density (BMD) of the hip in postmenopausal women. Japanese postmenopausal women (n = 94) were assigned at random to an exercise or control group (no exercise). The 6-month exercise program consisted of standing on a single foot for 1 min per leg 3 times per day. BMD of the hip was measured by dual-energy X-ray absorptiometry. There was no significant difference in age and baseline hip BMD between the exercise group (n = 49) and control group (n = 45). Exercise did not improve hip BMD compared with the control group. Stepwise regression analysis identified old age as a significant determinant (p = 0.034) of increased hip total BMD at 6 months after exercise. In 31 participants aged >/=70 years, the exercise group (n = 20) showed significant increase in the values of hip BMD at the areas of total (p = 0.008), intertrochanteric (p = 0.023), and Ward's triangle (p = 0.032). The same parameters were decreased in the control group (n = 11). The percent changes in hip BMD of the exercise group were not significantly different from those of the control group either in the participants with low baseline hip total BMD (<80% of the young adult mean) or high baseline hip total BMD (> or =80% of the young adult mean). In conclusion, unipedal standing exercise for 6 months did not improve hip BMD in Japanese postmenopausal women. Effect of exercise on hip total BMD was age dependent. In participants aged > or =70 years, the exercise significantly increased hip total BMD.

  4. Mid-term results of total knee arthroplasty with a porous tantalum monoblock tibial component.

    PubMed

    Hayakawa, Kazue; Date, Hideki; Tsujimura, Shunzo; Nojiri, Sho; Yamada, Harumoto; Nakagawa, Kenji

    2014-01-01

    The objectives of the present study were to assess the mid-term results of cementless total knee arthroplasty (TKA) with the porous tantalum monoblock tibial component and to examine the time course of bone changes on plain radiographs. The subjects were 32 patients, 29 patients were available for follow-up. We investigated the mid-term results of TKA after a mean follow-up period of 7 years and 8 months. We also examined changes of the bone over time on plain radiographs. The Knee Society Clinical Rating scores showed significant improvement. Bone changes around the tibial component were as follows: new bone formation and longitudinal trabecular thickening in 41.4% (Type A), only longitudinal trabecular thickening in 41.4% (Type B), and no changes in 17.2% (Type C). Type A and B changes were more frequent in patients with osteoarthritis, whereas Type C was only seen in patients with rheumatoid arthritis. Three knees had an initial gap, but this disappeared in all cases, and no new radiolucent lines were detected. Stress shielding was observed in seven knees (21.9%), but there was no implant loosening related to it. When we examined the relationship between the mechanical axis and the locations of the tips of the tibial pegs in patients with or without stress shielding, no significant differences were found. The results of mid-term follow-up have demonstrated favorable bone ingrowth, suggesting that porous tantalum is a promising material for cementless TKA. © 2013.

  5. Total hip arthroplasty in patients with dwarfism.

    PubMed

    Sekundiak, Todd D

    2005-09-01

    Skeletal dysplasia or dwarfism presents in a host of manners. Degenerative hip disease can present as a primary problem secondary to the abnormal growth disturbance or secondarily from the abnormal load distributions through the hip joint itself. Total hip arthroplasty is a successful procedure but sought with increased risks and complications when compared to routine hip arthroplasty. Custom or modular hip implants can help a surgeon manage the abnormal bone morphology seen with this condition.

  6. Effects of cemented versus press-fit primary humeral stem fixation in the setting of revision shoulder arthroplasty.

    PubMed

    Salesky, Madeleine A; Grace, Trevor R; Feeley, Brian T; Ma, C Benjamin; Zhang, Alan L

    2018-05-01

    The influence of primary humeral stem fixation method (cemented or press fit) on intraoperative or postoperative outcomes in the setting of revision shoulder arthroplasty is unknown. A retrospective analysis of a prospectively collected cohort of revision shoulder arthroplasty patients from a single tertiary center was performed. Demographic variables, intraoperative data, and 90-day complication rates were compared between cemented and press-fit primary stem fixation cohorts. Follow-up radiographs were graded and compared using a modified Gruen system for humeral lucencies. Eighty-six primary shoulder replacements (34 hemiarthroplasties, 39 anatomic total shoulder arthroplasties, 13 reverse total shoulder arthroplasties) underwent revision arthroplasty with humeral stem removal between 2004 and 2017. Forty-five patients had cemented primary humeral fixation and 41 had press-fit fixation. The cemented cohort was older than the cementless cohort (66.6 vs. 61.4 years; P = .03) but otherwise demonstrated no difference in gender, body mass index, type of primary prosthesis (hemi, total, or reverse), or time between primary and revision operations. The cemented and cementless cohorts showed similar rates of humeral osteotomy (28.9% vs. 29.3%; P = .97), operative time (133.5  vs. 121.3 minutes; P = .16), and 90-day complication rates (13.3% vs. 9.8%; P = .61). Cemented vs. press-fit primary stems also had similar rates of humeral lucencies seen on follow-up radiographs after revision (77.1% vs. 60.6%; P = .14). Humeral stem fixation with or without cement during primary shoulder arthroplasty demonstrated similar operative time, need for intraoperative humeral osteotomy, and postoperative complication rates in the setting of revision arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Primary total hip replacement for displaced subcapital fractures of the femur.

    PubMed

    Taine, W H; Armour, P C

    1985-03-01

    The management of displaced subcapital fracture of the hip is still controversial because of the high incidence of complications after internal fixation or hemiarthroplasty. To avoid some of these complications we have used primary total hip replacement for independently mobile patients over 65 years of age. A total of 163 cases, operated on over four years, have been reviewed. There were relatively more dislocations after operation for fracture than after total replacement for arthritis, and these were associated with a posterior approach to the hip. Only seven revision operations have been required. Of 57 patients who were interviewed an average of 42 months after replacement, 62% had excellent or good results as assessed by the Harris hip score. All the others had major systemic disease which affected their assessment. This inadequacy of current systems of hip assessment is discussed. It is concluded that total hip replacement is the best management for a selected group of patients with this injury, and that further prospective studies are indicated.

  8. [Revision hip arthroplasty by Waldemar Link custom-made total hip prosthesis].

    PubMed

    Medenica, Ivica; Luković, Milan; Radoicić, Dragan

    2010-02-01

    The number of patients undergoing hip arthroplasty revision is constantly growing. Especially, complex problem is extensive loss of bone stock and pelvic discontinuity that requires reconstruction. The paper presented a 50-year old patient, who ten years ago underwent a total cement artrhroplasty of the left hip. A year after the primary operation the patient had difficulties in walking without crutches. Problems intensified in the last five years, the patient had severe pain, totally limited movement in the left hip and could not walk at all. Radiographically, we found loose femoral component, massive loss of bone stock of proximal femur, acetabular protrusion and a consequent pelvic discontinuity. Clinically, a completely disfunctional left hip joint was registered (Harris hip score--7.1). We performed total rearthroplasty by a custom-made Waldemar Link total hip prosthesis with acetabular antiprotrusio cage and compensation of bone defects with a graft from the bone bank. A year after the operation, we found clinically an extreme improvement in Harris hip score--87.8. Radiographically, we found stability of implanted components, a complete graft integration and bone bridging across the site of pelvic discontinuity. Pelvic discontinuity and massive loss of proximal femoral bone stock is a challenging and complex entity. Conventional prostheses cannot provide an adequate fixation and stability of the hip. Application of custom-made prosthesis (measured specificaly for a patient) and additional alografting bone defects is a good method in revision surgery after unsuccessful hip arthroplasty with extensive bone defects.

  9. The effect of total hip and hip resurfacing arthroplasty on vertical ground reaction force and impulse symmetry during a sit-to-stand task.

    PubMed

    Caplan, N; Stewart, S; Kashyap, S; Banaszkiewicz, P; St Clair Gibson, A; Kader, D; Ewen, A

    2014-12-01

    The aim of this study was to determine the influence of total hip arthroplasty and hip resurfacing arthroplasty on limb loading symmetry before, and after, hip reconstruction surgery during a sit-to-stand task. Fourteen patients were recruited that were about to receive either a total hip prosthesis (n=7) or a hip resurfacing prosthesis (n=7), as well as matched controls. Patients performed a sit-to-stand movement before, 3 months after, and 12 months after surgery. Peak vertical ground reaction force and impulse were measured for each leg, from which ground reaction force and impulse symmetry ratios were calculated. Before surgery, hip resurfacing patients showed a small asymmetry which was not different to normal for ground reaction force (0.88(0.28) vs. 1.00(0.11); p=0.311) or impulse (0.87(0.29) vs. 0.99(0.09); p=0.324) symmetry ratios. Total hip patients offloaded their affected hip by 30% in terms of impulse symmetry ratio (0.71(0.36) vs. 0.99(0.23); p=0.018). At 3 months following surgery asymmetries were seen that were different to normal in both hip resurfacing patients for ground reaction force (0.77(0.16); p=0.007), and total hip patients for ground reaction force (0.70(0.15); p=0.018) and impulse (0.72(0.16); p=0.011) symmetry ratios. By 12 months after surgery total hip patients regained a symmetrical loading pattern for both ground reaction force (0.95(0.06); p=0.676) and impulse (1.00(0.06); p=0.702) symmetry ratios. Hip resurfacing patients, however, performed the task by overloading their operated hip, with impulse symmetry ratio being larger than normal (1.16(0.16); p=0.035). Physiotherapists should appreciate the need for early recovery of limb loading symmetry as well as subsequent differences in the responses observed with different prostheses. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Bearing Change to Metal-On-Polyethylene for Ceramic Bearing Fracture in Total Hip Arthroplasty; Does It Work?

    PubMed

    Lee, Soong Joon; Kwak, Hong Suk; Yoo, Jeong Joon; Kim, Hee Joong

    2016-01-01

    We evaluated the short-term to midterm results of reoperation with bearing change to metal-on-polyethylene (MoP) after ceramic bearing fracture in ceramic-on-ceramic total hip arthroplasty. Nine third-generation ceramic bearing fractures (6 heads and 3 liners) were treated with bearing change to MoP. Mean age at reoperation was 52.7 years. Mean follow-up was 4.3 years. During follow-up, 2 of 3 liner-fractured hips and 1 of 6 head-fractured hips showed radiologic signs of metallosis and elevated serum chromium levels. Re-reoperation with bearing rechange to a ceramic head was performed for the hips with metallosis. One liner-fractured hip had periprosthetic joint infection. Dislocation occurred in 3 hips. From our experience, bearing change to MoP is not a recommended treatment option for ceramic bearing fracture in total hip arthroplasty. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Living history in current orthopaedic hip surgery: intrapelvic teflon granuloma after total hip replacement.

    PubMed

    Gheorghiu, Daniel; Peter, Viju; Lynch, Martin

    2010-02-01

    The teflon hip arthroplasty design was used by Sir John Charnley in the early 60's but was taken off the market due to high complication rates. A case is reported of an intrapelvic granuloma after total hip arthroplasty following the use of a teflon socket. This appears to be the last surviving patient treated by Sir John Charnley using a Teflon hip socket design.

  12. Should gram stains have a role in diagnosing hip arthroplasty infections?

    PubMed

    Johnson, Aaron J; Zywiel, Michael G; Stroh, D Alex; Marker, David R; Mont, Michael A

    2010-09-01

    The utility of Gram stains in diagnosing periprosthetic infections following total hip arthroplasty has recently been questioned. Several studies report low sensitivity of the test, and its poor ability to either confirm or rule out infection in patients undergoing revision total hip arthroplasty. Despite this, many institutions including that of the senior author continue to perform Gram stains during revision total hip arthroplasty. We assessed the sensitivity, specificity, accuracy, and positive and negative predictive values of Gram stains from surgical-site samplings taken from procedures on patients with both infected and aseptic revision total hip arthroplasties. A review was performed on patients who underwent revision total hip arthroplasty between 2000 and 2007. Eighty-two Gram stains were performed on patients who had infected total hip arthroplasties and underwent revision procedures. Additionally, of the 410 revision total hip arthroplasties performed on patients who were confirmed infection-free, 120 Gram stains were performed. Patients were diagnosed as infected using multiple criteria at the time of surgery. Sensitivity, specificity, positive and negative predictive values, and accuracy were calculated from these Gram stain results. The Gram stain demonstrated a sensitivity and specificity of 9.8% and 100%, respectively. In this series, the Gram stain had a negative predictive value of 62%, a positive predictive value of 100%, and an accuracy of 63%. Gram stains obtained from surgical-site samples had poor sensitivity and poor negative predictive value. Based on these findings, as well as those of other authors, we believe that Gram stains should no longer be considered for diagnosing infections in revision total hip arthroplasty. Level III, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence.

  13. Sexual activity after total hip replacement in Korean patients: how they do, what they want, and how to improve.

    PubMed

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Lee, Young-Kyun; Koo, Kyung-Hoi

    2013-12-01

    Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial.

  14. Sexual Activity after Total Hip Replacement in Korean Patients: How They Do, What They Want, and How to Improve

    PubMed Central

    Yoon, Byung-Ho; Lee, Kyung-Hag; Noh, Serae; Ha, Yong-Chan; Koo, Kyung-Hoi

    2013-01-01

    Background Concerns of patients on sexual activity after total hip arthroplasty have not been well studied in Asian patients. This study aimed to determine the following: (1) what are the concerns of patients related to sexual activity after total hip arthroplasty? (2) what are the changes in sexual activity after total hip replacement in Korean patients? Methods Details of sexual activity and concerns were obtained using a questionnaire designed specifically for the study. The questionnaire was administered to 64 patients in a face-to-face interview at an outpatient clinic. Results Preoperatively, 53.1% of patients experienced difficulties, primarily due to hip pathology and limitations of motion. The median time to the resumption of sexual activity was 3 months postoperatively, and most patients had no increase in the frequency of sexual activity after the total hip replacement. In 39.1% of patients were seen having difficulties with leg positioning following total hip replacement, and they were likely to change coital positions. The most common concern regarding sexual activity of patients was the fear of dislocation. Furthermore, patients with a higher stress level had lower satisfaction rates. Most patients were unable to obtain information on sexual activity following the total hip arthroplasty, and they did not consult with a physician due to the private nature of the topic. Conclusions Dislocation was the most common concern of patients during sexual activity following a total hip arthroplasty, and a higher stress level was found to be associated with a lower satisfaction rate. Because most patients were unprepared to consult a physician, the provision of appropriate information before a consultation might be beneficial. PMID:24340146

  15. Bone-preserving total hip arthroplasty in avascular necrosis of the hip-a matched-pairs analysis.

    PubMed

    Merschin, David; Häne, Richard; Tohidnezhad, Mersedeh; Pufe, Thomas; Drescher, Wolf

    2018-07-01

    Short-stem hip arthroplasty has the potential advantage of femoral bone stock preservation, especially in view of the expected revisions in the often relatively young patients. Despite short-stem hip prosthesis are increasingly used for total hip arthroplasty, there are no sufficient mid- and long-term results especially for patients with avascular femoral head osteonecrosis. The present study investigates mid-term functional results as well as the revision rate following implantation of a short-stem prosthesis. In the period 06/2005 until 12/2013, a total of 351 short-stem hip prostheses were implanted. The study included 331 complete data sets. A retrospective analysis was performed using the Oxford Hip Score. All revisions were registered. In a total of 331 prostheses, the Oxford Hip Score was "excellent" in 66.2%, "good" in 12.7%, "fair" in 13.0%, and "poor" in 8.2% with a mean follow-up of 57.4 months (SD ± 29.8; range 24-115). In 26 cases, aseptic osteonecrosis of the hip was the indication (7.9%). The Oxford Hip Score was "excellent" in 66.7%, "good" in 0.0%, "fair" in 20.8%, and "poor" in 12.5%. The cumulated five year survival rate was 96.7%. In mid-term observation, the Metha® short-stem prosthesis shows no disadvantage in functional outcome and in survival time compared to a standard hip stem. Providing a correct indication, the Metha® short stem is a valuable option in total hip arthroplasty for younger patients with avascular osteonecrosis of the femoral head. Evaluation has shown no significant differences between aseptic osteonecrosis and other indications.

  16. Hip Rotation Range of Motion in People With and Without Low Back Pain Who Participate in Rotation-Related Sports

    PubMed Central

    Van Dillen, Linda R.; Bloom, Nancy J.; Gombatto, Sara P.; Susco, Thomas M.

    2008-01-01

    Objective To examine whether passive hip rotation motion was different between people with and without low back pain (LBP) who regularly participate in sports that require repeated rotation of the trunk and hips. We hypothesized that people with LBP would have less total hip rotation motion and more asymmetry of motion between sides than people without LBP. Design Two group, case-control. Setting University-based musculoskeletal analysis laboratory. Participants Forty-eight subjects (35 males, 13 females; mean age: 26.56±7.44 years) who reported regular participation in a rotation-related sport participated. Two groups were compared; people with LBP (N=24) and people without LBP (N=24; NoLBP). Main outcome measures Data were collected on participant-related, LBP-related, sport-related and activity-related variables. Measures of passive hip rotation range of motion were obtained. The differences between the LBP and NoLBP groups were examined. Results People with and without a history of LBP were the same with regard to all participant-related, sport-related and activity-related variables. The LBP group had significantly less total rotation (P=.035) and more asymmetry of total rotation, right hip versus left hip, (P=.022) than the NoLBP group. Left total hip rotation was more limited than right total hip rotation in the LBP group (P=.004). There were no significant differences in left and right total hip rotation for the NoLBP group (P=.323). Conclusions Among people who participate in rotation-related sports, those with LBP had less overall passive hip rotation motion and more asymmetry of rotation between sides than people without LBP. These findings suggest that the specific directional demands imposed on the hip and trunk during regularly performed activities may be an important consideration in deciding which impairments may be most relevant to test and to consider in prevention and intervention strategies. PMID:19081817

  17. [Comparison of early clinical effects of two hip prosthesis designs between ceramics to ceramics and metal to polyethylene].

    PubMed

    Yang, Li-qing; Li, Xi; Fu, Qin; Wang, Cheng

    2013-07-01

    To retrospectively study early therapeutic effects of the ceramics to ceramics prosthesis design in treating hip disease. From October 2007 to September 2010, 42 patients (44 hips) with hip disease underwent replacement of total hip. Hip prosthesis designs included the Pinnacle ceramics to ceramics and the Duraloc metal to polyethylene,produced by DePuy Company, all were non-bone cement type of artificial hip joint. Twenty patients (22 hips) were performed with ceramics to ceramics total hip prosthesis (CoC group, there were 12 males and 8 females, aged from 21 to 49 years) and 22 patients (22 hips) were performed with metal to polyethylene total hip prosthesis (MoP group, there were 13 males and 9 females, aged from 42 to 55 years). All the surgical approachs were posterolateral, and the routine anticoagulation and the corresponding functional exercise were performed after operation. The follow-up time was 6 months at least including clinical and radiographic observation. Measured the motion of joint and evaluated the function of hip joint according to Harris classification. All clinical effects were satisfactory and no dislocation ,loosening,infection, deep venous thrombosis and other complications occurred. There was no statistical significance in Harris scoring and the motion of joint between two groups before and after operation (P>0.05). The clinical effect of ceramics to ceramics prosthesis design in improving clinical symptoms and the motion of joint is coordinate with metal to polyethylene total hip prosthesis, however, its advantages and long-term efficacy need further observing. The ceramics to ceramics prosthesis design may be a good choice for the young patients with hip disease because of its good wear resistance.

  18. Perioperative Pain Management in Total Hip Arthroplasty: Korean Hip Society Guidelines

    PubMed Central

    Kim, Yeesuk; Cho, Hong-Man; Park, Kyung-Soon; Yoon, Pil Whan; Nho, Jae-Hwi; Kim, Sang-Min; Lee, Kyung-Jae; Moon, Kyong-Ho

    2016-01-01

    Effective perioperative pain management techniques and accelerated rehabilitation programs can improve health-related quality of life and functional status of patients after total hip arthroplasty. Traditionally, postoperative analgesia following arthroplasty was provided by intravenous patient-controlled analgesia or epidural analgesia. Recently, peripheral nerve blockade has emerged alternative analgesic approach. Multimodal analgesia strategy combines analgesics with different mechanisms of action to improve pain management. Intraoperative periarticular injection of multimodal drugs is one of the most important procedures in perioperative pain control for total hip arthroplasty. The goal of this review article is to provide a concise overview of the principles of multimodal pain management regimens as a practical guide for the perioperative pain management for total hip arthroplasty. PMID:27536639

  19. Lean mass and fat mass predict bone mineral density in middle-aged individuals with noninsulin-requiring type 2 diabetes mellitus.

    PubMed

    Moseley, Kendall F; Dobrosielski, Devon A; Stewart, Kerry J; De Beur, Suzanne M Jan; Sellmeyer, Deborah E

    2011-05-01

    Despite high bone mineral density (BMD), persons with type 2 diabetes are at greater risk of fracture. The relationship between body composition and BMD in noninsulin-requiring diabetes is unclear. The aim was to examine how fat and lean mass independently affect the skeleton in this population. Subjects for this cross-sectional analysis were men (n = 78) and women (n = 56) aged 40-65 years (56 ± 6 years) with uncomplicated, noninsulin-requiring type 2 diabetes. Total body fat and lean mass, total body, hip and lumbar spine BMD were measured with dual energy X-ray absorptiometry. Magnetic resonance imaging measured total abdominal, visceral and subcutaneous (SQ) fat. Subjects had normal all-site BMD and were obese to overweight (body mass index 29-41 kg/m(2)) with controlled diabetes (HbA1c women 6·6 ± 1·2%, men 6·7 ± 1·6%). Lean mass was positively associated with total body, hip, femoral neck and hip BMD in both sexes. Fat mass, abdominal total and SQ fat were associated with total body and hip BMD in women. In multivariate analyses adjusted for sex, lean mass significantly predicted total, hip and femoral neck BMD in men and women. In unadjusted models, lean mass continued to predict BMD at these sites in men; fat mass also predicted total body, femoral and hip BMD in women. In men and women with uncomplicated, noninsulin-requiring diabetes, lean mass significantly predicted BMD at the total body, hip and femoral neck. Further research is needed to determine whether acquisition or maintenance of lean mass in T2DM can prevent hip fracture in this at-risk population. © 2011 Blackwell Publishing Ltd.

  20. Manual calf massage and passive ankle motion reduce the incidence of deep vein thromboembolism after total hip arthroplasty.

    PubMed

    Imai, Norio; Ito, Tomoyuki; Suda, Ken; Miyasaka, Dai; Endo, Naoto

    2017-07-01

    Venous thromboembolism is one of the general complications following total hip arthroplasty, wherein various preventive treatments have been recommended. Several studies reported that venous thromboembolism incidence after total hip arthroplasty was similar in patients who were administered prophylaxis with a conventional mechanical procedure alone, and those who were administered pharmacological anticoagulation therapy. Therefore, the optimum methods of prophylaxis are still controversial. The purpose of this study was to investigate whether manual calf massage and passive ankle motion could lower the risk for venous thromboembolism after total hip arthroplasty. We retrospectively reviewed the data of 126 consecutive patients undergoing elective primary unilateral total hip arthroplasty wherein manual calf massage and passive ankle motion were performed after the surgery at our hospitals between January and October 2014. The 138 patients of the control group underwent total hip arthroplasty using the same surgical approach and pre- and postoperative protocols without this mechanical prophylaxis between January and December 2013. This mechanical prophylaxis was performed simultaneously 30 times during approximately 10 s; these procedures were repeated thrice immediately after total hip arthroplasty. Duplex ultrasonography was performed to observe the veins of both legs in all the patients on postoperative day 7. The incidence of deep vein thrombosis was 6.52% and 0.79% in the control and manual calf massage and passive ankle motion groups, respectively. The odds ratio for the manual calf massage and passive ankle motion groups was 8.72. Performing this mechanical prophylaxis reduced the incidence of venous thromboembolism after total hip arthroplasty. This mechanical prophylaxis is not only simple and easy, but is also safe and inexpensive. We therefore recommend that manual calf massage and passive ankle motion be performed in patients who will undergo total hip arthroplasty, if deep vein thrombosis does not exist before the surgery. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  1. Compatibility of the totally replaced hip. Reduction of wear by amorphous diamond coating.

    PubMed

    Santavirta, Seppo

    2003-12-01

    Particulate wear debris in totally replaced hips causes adverse local host reactions. The extreme form of such a reaction, aggressive granulomatosis, was found to be a distinct condition and different from simple aseptic loosening. Reactive and adaptive tissues around the totally replaced hip were made of proliferation of local fibroblast like cells and activated macrophages. Methylmethacrylate and high-molecular-weight polyethylene were shown to be essentially immunologically inert implant materials, but in small particulate form functioned as cellular irritants initiating local biological reactions leading to loosening of the implants. Chromium-cobalt-molybdenum is the most popular metallic implant material; it is hard and tough, and the bearings of this metal are partially self-polishing. In total hip implants, prerequisites for longevity of the replaced hip are good biocompatibility of the materials and sufficient tribological properties of the bearings. The third key issue is that the bearing must minimize frictional shear at the prosthetic bone-implant interface to be compatible with long-term survival. Some of the approaches to meet these demands are alumina-on-alumina and metal-on-metal designs, as well as the use of highly crosslinked polyethylene for the acetabular component. In order to avoid the wear-based deleterious properties of the conventional total hip prosthesis materials or coatings, the present work included biological and tribological testing of amorphous diamond. Previous experiments had demonstrated that a high adhesion of tetrahedral amorphous carbon coatings to a substrate can be achieved by using mixing layers or interlayers. Amorphous diamond was found to be biologically inert, and simulator testing indicated excellent wear properties for conventional total hip prostheses, in which either the ball or both bearing surfaces were coated with hydrogen-free tetrahedral amorphous diamond films. Simulator testing with such total hip prostheses showed no measurable wear or detectable delamination after 15,000,000 test cycles corresponding to 15 years of clinical use. The present work clearly shows that wear is one of the basic problems with totally replaced hips. Diamond coating of the bearing surfaces appears to be an attractive solution to improve longevity of the totally replaced hip.

  2. Comparison of outcome measures and complication rates following three different approaches for primary total hip arthroplasty: a pragmatic randomised controlled trial.

    PubMed

    Talia, Adrian J; Coetzee, Cassandra; Tirosh, Oren; Tran, Phong

    2018-01-08

    Total hip arthroplasty is one of the most commonly performed surgical procedures worldwide. There are a number of surgical approaches for total hip arthroplasty and no high-level evidence supporting one approach over the other. Each approach has its unique benefits and drawbacks. This trial aims to directly compare the three most common surgical approaches for total hip arthroplasty. This is a single-centre study conducted at Western Health, Melbourne, Australia; a large metropolitan centre. It is a pragmatic, parallel three-arm, randomised controlled trial. Sample size will be 243 participants (81 in each group). Randomisation will be secure, web-based and managed by an independent statistician. Patients and research team will be blinded pre-operatively, but not post-operatively. Intervention will be either direct anterior, lateral or posterior approach for total hip arthroplasty, and the three arms will be directly compared. Participants will be aged over 18 years, able to provide informed consent and recruited from our outpatients. Patients who are having revision surgery or have indications for hip replacement other than osteoarthritis (i.e., fracture, malignancy, development dysplasia) will be excluded from the trial. The Oxford Hip Score will be determined for patients pre-operatively and 6 weeks, 6, 12 and 24 months post-operatively. The Oxford Hip Score at 24 months will be the primary outcome measure. Secondary outcome measures will be dislocation, infection, intraoperative and peri-prosthetic fracture rate, length of hospital stay and pain level, reported using a visual analogue scale. Many studies have evaluated approaches for total hip arthroplasty and arthroplasty registries worldwide are now collecting this data. However no study to date has compared these three common approaches directly in a randomised fashion. No trial has used patient-reported outcome measures to evaluate success. This pragmatic study aims to identify differences in patient perception of total hip arthroplasty depending on surgical approach. Australian New Zealand Clinical Trials Registry, ACTRN12617000272392 . Registered on 22 February 2017.

  3. Long-term outcome of total hip arthroplasty in patients with haemophilia.

    PubMed

    Strauss, A C; Rommelspacher, Y; Nouri, B; Bornemann, R; Wimmer, M D; Oldenburg, J; Pennekamp, P H; Schmolders, J

    2017-01-01

    Besides the target joints (elbow, knee and ankle), the hip is one of the commonly affected joints in haemophilic arthropathy. Hip arthroplasty is the therapy of choice after failure of conservative treatment. There are only limited data on long-term results after primary total hip arthroplasty (THA). The aim of this retrospective study was to analyse clinical outcome and complication rate after total hip replacement in patients with severe haemophilic arthropathy. Forty-three patients with haemophilia (PWH), one patient with von Willebrand disease and one patient with a Factor-VII-deficiency undergoing 49 total hip arthroplasties, were evaluated in a retrospective study. Harris hip score (HHS), range of motion (ROM), pain status (visual analogue scale, VAS) complication rate and patient satisfaction were assessed at a mean follow-up of 11.5 years (range: 3-32). HSS, ROM and VAS improved significantly combined with high patient satisfaction. In total, three (6.1%) periprosthetic infections and five (10.2%) aseptic implant loosenings occurred after THA leading to revision arthroplasty. In two (4.1%) cases, a pseudotumour and one (2.0%) periarticular ossification had to be resected after THA. Total hip replacement in PWH leads to a significant increase of function, reduction of pain and a high satisfaction. Due to the relatively high complication rate (infections and aseptic loosening) compared to patients without haemophilia, an individual assessment of the risk-benefit ratio from surgical and haemostaseological point of view is needed. © 2016 John Wiley & Sons Ltd.

  4. Total hip arthroplasty for Crowe IV hip without subtrochanteric shortening osteotomy -a long term follow up study.

    PubMed

    Kawai, Toshiyuki; Tanaka, Chiaki; Kanoe, Hiroshi

    2014-03-10

    Several authors reported encouraging results of total hip arthroplasty (THA) for Crowe IV hips performed using shortening osteotomy. However, few papers have documanted the results of THA for Crowe IV hips without shortening osteotomy. The aim of the present study was to assess the long term-results of cemented THAs for Crowe group IV hips performed without subtrochanteric shortening osteotomy. We have assessed the long term results of 27 cemented total hip arthroplasty (THA) performed without subtrochanteric osteotomy for Crowe group IV hip. All THAs were performed via transtrochanteric approach. After a mean follow-up of 10.6 (6 to 17.9) years, 25 hips (92.6%) had survived without revision surgery and survivorship analysis gave a survival rate of 96.3% at 10 years with any revision surgery as the end point. Although mean limb lengthening was 3.2 (1.0 to 5.1) cm, no hips developed nerve palsy. Complications occurred in four hips, necessitating revision surgery in two. Among the four complications, three involved the greater trochanter, two of which occurred in cases where braided cables had been used to reattach the greater trochanter. Although we encountered four complications, including three trochanteric problems, our findings suggest that THA without subtrochanteric shortening osteotomy can provide satisfactory long-term results in patients with Crowe IV hip.

  5. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis.

    PubMed

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-06-01

    Background and purpose - There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods - We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994-2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results - We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients' HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6-17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation - Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients.

  6. Cirrhosis is a risk factor for total hip arthroplasty for avascular necrosis

    PubMed Central

    Deleuran, Thomas; Overgaard, Søren; Vilstrup, Hendrik; Jepsen, Peter

    2016-01-01

    Background and purpose There are limited data on risk factors for avascular necrosis of the hip, but cirrhosis has been proposed as a risk factor. We examined the association between cirrhosis and incidence of total hip arthroplasty for avascular necrosis. Methods We used nationwide healthcare data to identify all Danish residents diagnosed with cirrhosis in 1994–2011, and matched them 1:5 by age and sex to non-cirrhotic reference individuals from the general population. We excluded people with a previous total hip arthroplasty, a previous hip fracture, or a previous diagnosis of avascular necrosis. We used stratified Cox regression to estimate the hazard ratio (HR) for cirrhosis patients relative to reference individuals, adjusting for potential confounders. We used the cumulative incidence function to compute 5-year risks. Results We included 25,421 cirrhosis patients and 114,052 reference individuals. Their median age was 57 years, and 65% were men. 45 cirrhosis patients and 44 reference individuals underwent total hip arthroplasty for avascular necrosis. Cirrhosis patients’ HR for a total hip arthroplasty for avascular necrosis was 10 (95% CI: 6–17), yet their 5-year risk of avascular necrosis was only 0.2%. For the reference individuals, the 5-year risk was 0.02%. Interpretation Cirrhosis is a strong risk factor for avascular necrosis of the hip, but it is rare even in cirrhosis patients. PMID:26900635

  7. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study.

    PubMed

    Harikesavan, Karvannan; Chakravarty, Raj D; Maiya, Arun G; Hegde, Sanjay P; Y Shivanna, Shivakumar

    2017-01-01

    Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement.

  8. Hip Abductor Strengthening Improves Physical Function Following Total Knee Replacement: One-Year Follow-Up of a Randomized Pilot Study

    PubMed Central

    Harikesavan, Karvannan; Chakravarty, Raj D.; Maiya, Arun G; Hegde, Sanjay P.; Y. Shivanna, Shivakumar

    2017-01-01

    Background: Total knee replacement (TKR) is the commonest surgical procedure for patients with severe pain and impaired physical function following end stage knee osteoarthritis. The hip abductors are well renowned in stabilization of the trunk and hip during walking, maintaining the lower limb position, and transferring the forces from the lower limbs to the pelvis. Objective: To assess the efficacy of hip abductor strengthening exercise on functional outcome using performance based outcome measures following total knee replacement. Methods: An observer blinded randomized pilot trial design was conducted at Manipal hospital, Bangalore, India. Participants designated for elective TKR were randomized to experimental group hip abductor strengthening along with standard rehabilitation (n=10) or control group standard rehabilitation alone (n=10). Participants followed for one year to assess physical function using performance based outcomes, such as timed up and go test, single leg stance test, six minute walk test, knee extensor strength and hip abductor strength. Result: Eighteen participants with a mean age of 63.1 ± 5.5 years (8 Males and 10 Females) completed the study. Improvement in hip abduction strength, single leg stand test was superior in hip abductor strengthening group at 3 months and 1 year when compared to standard rehabilitation alone. Conclusion: Hip abductor strengthening showed superior improvements in single leg stance test and six minute walk test. Hip abductor strengthening exercises has the potential to improve physical function following total knee replacement. PMID:28567148

  9. The operation of the century: total hip replacement.

    PubMed

    Learmonth, Ian D; Young, Claire; Rorabeck, Cecil

    2007-10-27

    In the 1960s, total hip replacement revolutionised management of elderly patients crippled with arthritis, with very good long-term results. Today, young patients present for hip-replacement surgery hoping to restore their quality of life, which typically includes physically demanding activities. Advances in bioengineering technology have driven development of hip prostheses. Both cemented and uncemented hips can provide durable fixation. Better materials and design have allowed use of large-bore bearings, which provide an increased range of motion with enhanced stability and very low wear. Minimally invasive surgery limits soft-tissue damage and facilitates accelerated discharge and rehabilitation. Short-term objectives must not compromise long-term performance. Computer-assisted surgery will contribute to reproducible and accurate placement of implants. Universal economic constraints in healthcare services dictate that further developments in total hip replacement will be governed by their cost-effectiveness.

  10. [Radiographic appraisal between metal and bone interosculate backfill after total hip arthroplasty with trabecular metal cup].

    PubMed

    Li, Wei; Zhou, Yi-Xin; Wu, Jian; Xu, Hui; Ji, Song-Jie

    2009-02-15

    To evaluate the bone refilling in the interface between the trabecular metal (TM) acetabular shell and the bone surface according to consecutive X film measuring after surgery. From July 2006 to July 2007, 35 patients (40 hips) accepted total hip replacement using trabecular metal monoblock acetabular cup system (TM). The cup was made of a ellipse shaped press fit Tantalum shell and high cross-linked PE liner (Longevity) with 28 mm inner diameter. The patients demography was: 16 male (20 hips), 19 female (20 hips), 5 bilateral hip replacements, age from 41 - 71 (mean 53), including 18 avascular necrosis hips, 16 osteoarthritis hips (including those secondary to a dysplasia hip), 4 avascular necrosis hips after femoral neck fracture, 2 Ankylosis Spondylitis. All the 40 total hip replacements used posterior approach, using hemispherical acetabular reamer and 2 mm press fit of final metal shell without screw fixation. The consecutive X film was taken at the end time of surgery and 2, 6, 12, 24 weeks, and 12 months. The clinical results was evaluate according to Harris scoring system, and the standard pelvis AP X film was measured at the interface between metal shell and the acetabular bone surface, witch was divided into five regions (A, B, C, D, E). Totally 32 patients (37 hips) were followed with average 8.7 months (7 - 12 months). The Harris before surgery was 50.5 (32 - 85), promoted to 91.0 (72 - 100), including 29 excellent, 6 good, 2 fair, and the total excellent and good rate was 94.6%. Complications include 4 patients leg length discrepancy from 1 - 2 cm, 3 patients moderate thigh pain and released after conservative therapy. No infection and dislocation was found. Twenty-one patients (23 hips) were found lucent line at the bone-metal interface from 1 - 5 mm, most common in B region and BC boundary than C, D, and CD boundary. All the patients followed was found the lucent line disappeared and refilled with bone at X film 24 weeks after surgery, however, no patients was found osteolysis and cup migration. The trabecular metal has strong capacity of bone conductive and bone inducement.

  11. Primary total hip arthroplasty versus hemiarthroplasty for displaced intracapsular hip fractures in older patients: systematic review.

    PubMed

    Hopley, Colin; Stengel, Dirk; Ekkernkamp, Axel; Wich, Michael

    2010-06-11

    To determine whether total hip arthroplasty is associated with lower reoperation rates, mortality, and complications, and better function and quality of life than hemiarthroplasty for displaced fractures of the femoral neck in older patients. Systematic review and meta-analysis of randomised trials, quasirandomised trials, and cohort studies. Medline, Embase, Cochrane register of controlled trials, publishers' databases, and manual search of bibliographies. Randomised controlled trials, quasirandomised trials, and cohort studies (retrospective and prospective) comparing hemiarthroplasty with total hip arthroplasty for treating displaced femoral neck fractures in patients aged more than 60 years. Relative risks, risk differences, and mean differences from each trial, aggregated using random effects models. Analyses were stratified for experimental and non-experimental designs, and two way sensitivity analyses and tests for interaction were done to assess the influence of various criteria of methodological quality on pooled estimates. 3821 references were identified. Of the 202 full papers inspected, 15 were included (four randomised controlled trials, three quasirandomised trials, and eight retrospective cohort studies, totalling 1890 patients). Meta-analysis of 14 studies showed a lower risk of reoperation after total hip arthroplasty compared with hemiarthroplasty (relative risk 0.57, 95% confidence interval 0.34 to 0.96, risk difference 4.4%, 95% confidence interval 0.2% to 8.5%), although this effect was mainly driven by investigations without concealed treatment allocation. Total hip arthroplasty consistently showed better ratings in the Harris hip score (three studies, 246 patients, weighted mean difference 5.4, 95% confidence interval 2.7 to 8.2) after follow-up periods of 12 to 48 months. The standardised mean difference of different scores from five studies was 0.42 (95% confidence interval 0.24 to 0.61), indicating a medium functional advantage of total hip arthroplasty over hemiarthroplasty. Total hip arthroplasty was associated with a slightly higher risk of dislocation (relative risk 1.48, 95% confidence interval 0.89 to 2.46) and general complications (1.14, 0.87 to 1.48). Single stage total hip arthroplasty may lead to lower reoperation rates and better functional outcomes compared with hemiarthroplasty in older patients with displaced femoral neck fractures. However, heterogeneity across the available trials and distinct subgroup effects preclude definitive statements and require further research in this area.

  12. Predictors for Long-Term Hip Survivorship Following Acetabular Fracture Surgery: Importance of Gap Compared with Step Displacement.

    PubMed

    Verbeek, Diederik O; van der List, Jelle P; Tissue, Camden M; Helfet, David L

    2018-06-06

    Historically, the greatest residual (gap or step) displacement is used to predict clinical outcome following acetabular fracture surgery. Gap and step displacement may, however, impact the outcome to different degrees. We assessed the individual relationship between gap or step displacement and hip survivorship and determined their independent association with conversion to total hip arthroplasty. Patients who had acetabular fracture fixation (from 1992 through 2014), follow-up of ≥2 years (or early conversion to total hip arthroplasty), and postoperative computed tomography (CT) scans were included. Of 227 patients, 55 (24.2%) had conversion to total hip arthroplasty at a mean follow-up (and standard deviation) of 8.7 ± 5.6 years. Residual gap and step displacement were measured using a standardized CT-based method, and assessors were blinded to the outcome. Kaplan-Meier survivorship curves for the hips were plotted and compared (log-rank test) using critical cutoff values for gap and step displacement. These values were identified using receiver operating characteristic curves. Multivariate analysis was performed to identify independent variables associated with conversion to total hip arthroplasty. Subgroup analysis was performed in younger patients (<50 years old). The critical CT cutoff value for total hip arthroplasty conversion was 5 mm for gap and 1 mm for step displacement. Hip survivorship at 10 years was 82.0% for patients with a gap of <5 mm compared with 56.5% for a gap of ≥5 mm (p < 0.001) and 80.0% for a step of <1.0 mm versus 65.5% for a step of ≥1.0 mm (p = 0.012). A gap of ≥5 mm (hazard ratio [HR], 2.3; p = 0.012) and an age of ≥50 years (HR, 4.2; p < 0.001) were independently associated with conversion to total hip arthroplasty in all patients. In the subgroup of younger patients, only a step of ≥1 mm (HR, 6.4; p = 0.017) was an independent factor for conversion to total hip arthroplasty. Residual gap and step displacement as measured on CT scans are both related to long-term hip survivorship, but step displacement (1 mm) is tolerated less than gap displacement (5 mm). Of the 2 types of displacement, only a large gap displacement (≥5 mm) was independently associated with conversion to total hip arthroplasty. In younger patients who had less articular impaction with smaller residual gaps, only step displacement (≥1 mm) appeared to be associated with this outcome. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  13. The efficacy of modified direct lateral versus posterior approach on gait function and hip muscle strength after primary total hip arthroplasty at 12months follow-up. An explorative randomised controlled trial.

    PubMed

    Rosenlund, Signe; Broeng, Leif; Overgaard, Søren; Jensen, Carsten; Holsgaard-Larsen, Anders

    2016-11-01

    The lateral and the posterior approach are the most commonly used procedures for total hip arthroplasty. Due to the detachment of the hip abductors, lateral approach is claimed to cause reduced hip muscle strength and altered gait pattern. However, this has not been investigated in a randomised controlled trial. The aim was to compare the efficacy of total hip arthroplasty performed by lateral or posterior approach on gait function and hip muscle strength up to 12months post-operatively. We hypothesised that posterior approach would be superior to lateral approach. Forty-seven patients with primary hip osteoarthritis were randomised to total hip arthroplasty with either posterior or lateral approach and evaluated pre-operatively, 3 and 12months post-operatively using 3-dimensional gait analyses as objective measures of gait function, including Gait Deviation Index, temporo-spatial parameters and range of motion. Isometric maximal hip muscle strength in abduction, flexion and extension was also tested. Post-operatively, no between-group difference in gait function was observed. However, both hip abductor and flexor muscle strength improved more in the posterior approach group: -0.20(Nm/kg)[95%CI:-0.4 to 0.0] and -0.20(Nm/kg)[95%CI:-0.4 to 0.0], respectively. Contrary to our first hypothesis, the overall gait function in the posterior approach group did not improve more than in the lateral approach group. However, in agreement with our second hypothesis, patients in the posterior approach group improved more in hip abductor and flexor muscle strength at 12months. Further investigation of the effect of reduced maximal hip muscle strength on functional capacity is needed. ClinicalTrials.gov. No.: NCT01616667. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Single-stage Acetabular Revision During Two-stage THA Revision for Infection is Effective in Selected Patients.

    PubMed

    Fink, Bernd; Schlumberger, Michael; Oremek, Damian

    2017-08-01

    The treatment of periprosthetic infections of hip arthroplasties typically involves use of either a single- or two-stage (with implantation of a temporary spacer) revision surgery. In patients with severe acetabular bone deficiencies, either already present or after component removal, spacers cannot be safely implanted. In such hips where it is impossible to use spacers and yet a two-stage revision of the prosthetic stem is recommended, we have combined a two-stage revision of the stem with a single revision of the cup. To our knowledge, this approach has not been reported before. (1) What proportion of patients treated with single-stage acetabular reconstruction as part of a two-stage revision for an infected THA remain free from infection at 2 or more years? (2) What are the Harris hip scores after the first stage and at 2 years or more after the definitive reimplantation? Between June 2009 and June 2014, we treated all patients undergoing surgical treatment for an infected THA using a single-stage acetabular revision as part of a two-stage THA exchange if the acetabular defect classification was Paprosky Types 2B, 2C, 3A, 3B, or pelvic discontinuity and a two-stage procedure was preferred for the femur. The procedure included removal of all components, joint débridement, definitive acetabular reconstruction (with a cage to bridge the defect, and a cemented socket), and a temporary cemented femoral component at the first stage; the second stage consisted of repeat joint and femoral débridement and exchange of the femoral component to a cementless device. During the period noted, 35 patients met those definitions and were treated with this approach. No patients were lost to followup before 2 years; mean followup was 42 months (range, 24-84 months). The clinical evaluation was performed with the Harris hip scores and resolution of infection was assessed by the absence of clinical signs of infection and a C-reactive protein level less than 10 mg/L. All patients were assessed before surgery, between stages, every 3 months during the first year after surgery, every 6 months during the second year postoperative, and at latest followup, and were retrospectively drawn from a longitudinally maintained institutional database. Thirty-four of 35 patients (97.2%; 95% CI, 85.4%-99.5%) appeared free of infection by criteria of Masri et al. and Zimmerli et al. at latest followup. The Harris hip score was 61 ± 13 points after the first operation and 82 ± 16 points 2 years after the second operation. This technique is a promising treatment option for periprosthetic infections of the hip in which substantial acetabular defects exclude implantation of a normal spacer and a two-stage revision of the femoral component is favored. Level IV, therapeutic study.

  15. Cemented total hip replacement cable debris and acetabular construct durability.

    PubMed

    Altenburg, Aaron J; Callaghan, John J; Yehyawi, Tameem M; Pedersen, Douglas R; Liu, Steve S; Leinen, Jessica A; Dahl, Kevin A; Goetz, Devon D; Brown, Thomas D; Johnston, Richard C

    2009-07-01

    Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% +/- 9% and 83% +/- 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal.

  16. Total hip replacement for hip fracture: Surgical techniques and concepts.

    PubMed

    Coomber, Ross; Porteous, Matthew; Hubble, Matthew J W; Parker, Martyn J

    2016-10-01

    When treating a hip fracture with a total hip replacement (THR) the surgical technique may differ in a number of aspects in comparison to elective arthroplasty. The hip fracture patient is more likely to have poor bone stock secondary to osteoporosis, be older, have a greater number of co-morbidities, and have had limited peri-operative work-up. These factors lead to a higher risk of complications, morbidity and perioperative mortality. Consideration should be made to performing the THR in a laminar flow theatre, by a surgeon experienced in total hip arthroplasty, using an anterolateral approach, cementing the implant in place, using a large head size and with repair of the joint capsule. Combined Ortho-geriatric care is recommended with similar post-operative rehabilitation to elective THR patients but with less expectation of short length of stay and consideration for fracture prevention measures. Copyright © 2016. Published by Elsevier Ltd.

  17. A biomechanical comparison of four different cementless press-fit stems used in revision surgery for total knee replacements.

    PubMed

    Zdero, Radovan; Saidi, Kevan; Mason, Stephanie A; Schemitsch, Emil H; Naudie, Douglas D R

    2012-11-01

    Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462 N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.

  18. Estimation of wear in total hip replacement using a ten station hip simulator.

    PubMed

    Brummitt, K; Hardaker, C S

    1996-01-01

    The results of hip simulator tests on a total of 16 total hip joints, all of them 22.25 mm Charnley designs, are presented. Wear at up to 6.75 million cycles was assessed by using a coordinate measuring machine. The results gave good agreement with clinical estimates of wear rate on the same design of joint replacement from a number of sources. Good agreement was also obtained when comparison was made with the published results from more sophisticated simulators. The major source of variation in the results was found to occur in the first million cycles where creep predominates. The results of this study support the use of this type of simplified simulator for estimating wear in a total hip prosthesis. The capability to test a significant number of joints simultaneously may make this mechanism preferable to more complex machines in many cases.

  19. Direct costs of osteoporosis and hip fracture: an analysis for the Mexican healthcare system.

    PubMed

    Clark, P; Carlos, F; Barrera, C; Guzman, J; Maetzel, A; Lavielle, P; Ramirez, E; Robinson, V; Rodriguez-Cabrera, R; Tamayo, J; Tugwell, P

    2008-03-01

    This study reports the direct costs related to osteoporosis and hip fractures paid for governmental and private institutions in the Mexican health system and estimates the impact of these entities on Mexico. We conclude that the economic burden due to the direct costs of hip fracture justifies wide-scale prevention programs for osteoporosis (OP). To estimate the total direct costs of OP and hip fractures in the Mexican Health care system, a sample of governmental and private institutions were studied. Information was gathered through direct questionnaires in 275 OP patients and 218 hip fracture cases. Additionally, a chart review was conducted and experts' opinions obtained to get accurate protocol scenarios for diagnoses and treatment of OP with no fracture. Microcosting and activity-based costing techniques were used to yield unit costs. The total direct costs for OP and hip fracture were estimated for 2006 based on the projected annual incidence of hip fractures in Mexico. A total of 22,233 hip fracture cases were estimated for 2006 with a total cost to the healthcare system of US$ 97,058,159 for the acute treatment alone ($4,365.50 per case). We found considerable differences in costs and the way the patients were treated across the different health sectors within the country. Costs of the acute treatment of hip fractures in Mexico are high and are expected to increase with the predicted increment of life expectancy and the number of elderly in our population.

  20. Effects of preoperative physiotherapy in hip osteoarthritis patients awaiting total hip replacement

    PubMed Central

    Czyżewska, Anna; Walesiak, Katarzyna; Krawczak, Karolina; Cabaj, Dominika; Górecki, Andrzej

    2014-01-01

    Introduction The World Health Organization (WHO) claimed osteoarthritis as a civilization-related disease. The effectiveness of preoperative physiotherapy among patients suffering hip osteoarthritis (OA) at the end of their conservative treatment is rarely described in the literature. The aim of this study was to assess the quality of life and musculoskeletal health status of patients who received preoperative physiotherapy before total hip replacement (THR) surgery within a year prior to admission for a scheduled THR and those who did not. Material and methods Forty-five patients, admitted to the Department of Orthopaedics and Traumatology of Locomotor System for elective total hip replacement surgery, were recruited for this study. The assessment consisted of a detailed interview using various questionnaires: the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the 36-Item Short Form Health Survey (SF-36), and the Hip disability and Osteoarthritis Outcome Score (HOOS), as well as physical examination. Patients were assigned to groups based on their attendance of preoperative physiotherapy within a year prior to surgery. Results Among patients who received preoperative physiotherapy a significant improvement was found for pain, daily functioning, vitality, psychological health, social life, and (active and passive) internal rotation (p < 0.05). Conclusions Patients are not routinely referred to physiotherapy within a year before total hip replacement surgery. This study confirmed that pre-operative physiotherapy may have a positive influence on selected musculoskeletal system status indicators and quality of life in hip osteoarthritis patients awaiting surgery. PMID:25395951

  1. Spine–hip relations in patients with hip osteoarthritis

    PubMed Central

    Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah

    2018-01-01

    Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844

  2. A Water Rehabilitation Program in Patients with Hip Osteoarthritis Before and After Total Hip Replacement.

    PubMed

    Łyp, Marek; Kaczor, Ryszard; Cabak, Anna; Tederko, Piotr; Włostowska, Ewa; Stanisławska, Iwona; Szypuła, Jan; Tomaszewski, Wiesław

    2016-07-25

    BACKGROUND Pain associated with coxarthrosis, typically occurring in middle-aged and elderly patients, very commonly causes considerable limitation of motor fitness and dependence on pharmacotherapy. This article provides an assessment of a rehabilitation program with tailored water exercises in patients with osteoarthritis before and after total hip replacement. MATERIAL AND METHODS A total of 192 patients (the mean age 61.03±10.89) suffering from hip osteoarthritis (OA) were evaluated before and after total hip replacement (THR). The clinical study covered measurements of hip active ranges of motion (HAROM) and the forces generated by pelvis stabilizer muscles. Pain intensity was assessed according to analogue-visual scale of pain (VAS) and according to the Modified Laitinen Questionnaire. The patients were divided into 6 groups (4 treatment and 2 control). We compared 2 rehabilitation programs using kinesitherapy and low-frequency magnetic field. One of them also had specially designed exercises in the water. Statistical analysis was carried out at the significance level α=0.05. This was a cross-sectional study. RESULTS A positive effect of water exercises on a number of parameters was found in patients with OA both before and after total hip replacement surgery. We noted a significant reduction of pain (p<0.001), increased ranges of motion and muscle strength, and reduced use of medicines (NASAIDs) (p<0.001). A correlation was found between the degree of degenerative deforming lesions and the effects of the treatment process (p<0.01). CONCLUSIONS 1. The rehabilitation program including water exercises most significantly reduced pain in patients with OA before and after total hip replacement surgery. 2. Inclusion of water exercises in a rehabilitation program can reduce the use of medicines in patient with OA and after THR.

  3. Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement.

    PubMed

    Hua, Xijin; Wang, Ling; Al-Hajjar, Mazen; Jin, Zhongmin; Wilcox, Ruth K; Fisher, John

    2014-07-01

    Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid. © IMechE 2014.

  4. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    PubMed

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  5. Surgical anesthesia with a combination of T12 paravertebral block and lumbar plexus, sacral plexus block for hip replacement in ankylosing spondylitis: CARE-compliant 4 case reports.

    PubMed

    Ke, Xijian; Li, Ji; Liu, Yong; Wu, Xi; Mei, Wei

    2017-06-26

    Anesthesia management for patients with severe ankylosing spondylitis scheduled for total hip arthroplasty is challenging due to a potential difficult airway and difficult neuraxial block. We report 4 cases with ankylosing spondylitis successfully managed with a combination of lumbar plexus, sacral plexus and T12 paravertebral block. Four patients were scheduled for total hip arthroplasty. All of them were diagnosed as severe ankylosing spondylitis with rigidity and immobilization of cervical and lumbar spine and hip joints. A combination of T12 paravertebral block, lumbar plexus and sacral plexus block was successfully used for the surgery without any additional intravenous anesthetic or local anesthetics infiltration to the incision, and none of the patients complained of discomfort during the operations. The combination of T12 paravertebral block, lumbar plexus and sacral plexus block, which may block all nerves innervating the articular capsule, surrounding muscles and the skin involved in total hip arthroplasty, might be a promising alternative for total hip arthroplasty in ankylosing spondylitis.

  6. Revision total hip arthoplasty: factors associated with re-revision surgery.

    PubMed

    Khatod, Monti; Cafri, Guy; Inacio, Maria C S; Schepps, Alan L; Paxton, Elizabeth W; Bini, Stefano A

    2015-03-04

    The survivorship of implants after revision total hip arthroplasty and risk factors associated with re-revision are not well defined. We evaluated the re-revision rate with use of the institutional total joint replacement registry. The purpose of this study was to determine patient, implant, and surgeon factors associated with re-revision total hip arthroplasty. A retrospective cohort study was conducted. The total joint replacement registry was used to identify patients who had undergone revision total hip arthroplasty for aseptic reasons from April 1, 2001, to December 31, 2010. The end point of interest was re-revision total hip arthroplasty. Risk factors evaluated for re-revision total hip arthroplasty included: patient risk factors (age, sex, body mass index, race, and general health status), implant risk factors (fixation type, bearing surface, femoral head size, and component replacement), and surgeon risk factors (volume and experience). A multivariable Cox proportional hazards model was used. Six hundred and twenty-nine revision total hip arthroplasties with sixty-three (10%) re-revisions were evaluated. The mean cohort age (and standard deviation) was 57.0 ± 12.4 years, the mean body mass index (and standard deviation) was 29.5 ± 6.1 kg/m(2), and most of the patients were women (64.5%) and white (81.9%) and had an American Society of Anesthesiologists score of <3 (52.9%). The five-year implant survival after revision total hip arthroplasty was 86.8% (95% confidence interval, 83.57% to 90.25%). In adjusted models, age, total number of revision surgical procedures performed by the surgeon, fixation, and bearing surface were associated with the risk of re-revision. For every ten-year increase in patient age, the hazard ratio for re-revision decreases by a factor of 0.72 (95% confidence interval, 0.58 to 0.90). For every five revision surgical procedures performed by a surgeon, the risk of revision decreases by a factor of 0.93 (95% confidence interval, 0.86 to 0.99). At the time of revision, a new or retained cemented femoral implant or all-cemented hip implant increases the risk of revision by a factor of 3.19 (95% confidence interval, 1.22 to 8.38) relative to a retained or new uncemented hip implant. A ceramic on a highly cross-linked polyethylene bearing articulation decreases the hazard relative to metal on highly cross-linked polyethylene by a factor of 0.32 (95% confidence interval, 0.11 to 0.95). Metal on constrained bearing increases the hazard relative to metal on highly cross-linked polyethylene by a factor of 3.32 (95% confidence interval, 1.16 to 9.48). When evaluating patient, implant, and surgical factors at the time of revision total hip arthroplasty, age, surgeon experience, implant fixation, and bearing surfaces had significant impacts on the risk of re-revision. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  7. Comparison between topical and intravenous administration of tranexamic acid in primary total hip arthroplasty.

    PubMed

    Ueno, Masaya; Sonohata, Motoki; Fukumori, Norio; Kawano, Shunsuke; Kitajima, Masaru; Mawatari, Masaaki

    2016-01-01

    Tranexamic acid has been reported to be safer with topical administration than with intravenous administration in total knee arthroplasty. However, the most effective administration route of tranexamic acid in total hip arthroplasty remains controversial. This study compared the effectiveness of topical tranexamic acid administration with that of intravenous tranexamic acid administration in total hip arthroplasty. We retrospectively examined the medical records of 886 patients with osteoarthritis of the hip joint, who had undergone unilateral primary total hip arthroplasty. The patients were divided into a control group (n = 302; did not receive tranexamic acid), topical group (n = 265; topically administered 2 g tranexamic acid in 30 mL normal saline via drain tubes placed in the joint before wound closure along with posterior soft tissue repair), and intravenous group (n = 319; intravenously administered 1 g tranexamic acid before skin incision along with posterior soft tissue repair). Data on blood loss, hemoglobin levels, transfusion rates, and occurrence of deep vein thrombosis and pulmonary embolization were collected. The mean operation times were approximately 40 min in all of the groups. The operation time and intra-operative blood loss were significantly lower in the control group than in the topical and intravenous groups. However, the post-operative blood loss, total blood loss, and decrease in the hemoglobin level were significantly higher in the control group than in the topical and intravenous groups. There were no significant differences in terms of blood loss and systemic complications between the tranexamic acid administration methods. Tranexamic acid reduces both post-operative and total blood loss in total hip arthroplasty. Moreover, a lower amount of tranexamic acid can be used to reduce blood loss in total hip arthroplasty with intravenous tranexamic acid administration than with topical tranexamic acid administration. Therefore, we suggest that tranexamic acid should be intravenously administered pre-operatively and the posterior soft tissue should be repaired to decrease total hip arthroplasty-related complications. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Characteristics and Trends of Published Adult Hip Research over the Last Decade

    PubMed Central

    Kwak, Hong Suk; Yoon, Pil Whan; Park, Moon Seok; Kim, Hee Joong

    2015-01-01

    Purpose We designed this study to demonstrate recent trends in the proportion of adult hip research in orthopedics, to identify countries leading the adult hip research, and to evaluate the relationship between the economic power of the countries and their contributions. Materials and Methods Studies published in seven select orthopedic journals were retrieved from PubMed. Among them, we determined the number of adult hip studies. The countries-of-origin of adult hip studies, and the economic power of the countries were investigated. Results A total of 7218 orthopedic publications and 1993 (27.6%) addressed adult hip research were identified. Adult hip studies increased from 313 (23.7%) in 2000 to 555 (27.9%) in 2011. Twenty-five countries accounted for 97.6% of the total number of adult hip studies, and gross domestic product correlated with publication volume (Spearman's rho, 0.723; p=0.000). Conclusion Researchers from a limited number of developed countries have published their studies in the adult hip discipline. PMID:25510756

  9. Primary total hip replacement versus hip resurfacing - hospital considerations.

    PubMed

    Ward, William G; Carter, Christina J; Barone, Marisa; Jinnah, Riyaz

    2011-01-01

    Multiple factors regarding surgical procedures and patient selection affect hospital staffing needs as well as hospital revenues. In order to better understand the potential impact on hospitals that hip arthroplasty device selection (standard total hip arthroplasty vs. resurfacing) creates, a review of all primary hip arthroplasties performed at one institution was designed to identify factors that impacted hospital staffing needs and revenue generation. All primary hip arthroplasties undertaken over three fiscal years (2008 to 2010) were reviewed, utilizing only hospital business office data and medical records data that had been previously extracted prior for billing purposes. Analysis confirmed differing demographics for two hip arthroplasty populations, with the resurfacing patients (compared to the conventional total hip arthroplasty population) consisting of younger patients (mean age, 50 vs. 61 years), who were more often male (75% vs. 45%), were more likely to have osteoarthritis as their primary diagnosis (83 vs. 67%) and were more often covered by managed care or commercial insurance (83 vs. 34%). They also had shorter hospital stays (mean length of stay, 2.3 vs. 4.1 days) and consequently provided a more favorable financial revenue stream to the hospital on a per patient basis. Several trends appeared during the study periods. There was a steady increase in all procedures in all groups except for the resurfacings, which decreased 26% in males and 53% in females between 2009 and 2010. Differences were observed in the demographics of patients presenting for resurfacing, compared to those presenting for conventional total hip arthroplasty. In addition to the revenue stream considerations, institutions undertaking a resurfacing program must commit the resources and planning in order to rehabilitate these patients more expeditiously than is usually required with conventional hip arthroplasty patients.

  10. Total medical costs of treating femoral neck fracture patients with hemi- or total hip arthroplasty: a cost analysis of a multicenter prospective study.

    PubMed

    Burgers, P T P W; Hoogendoorn, M; Van Woensel, E A C; Poolman, R W; Bhandari, M; Patka, P; Van Lieshout, E M M

    2016-06-01

    The aim of this study was to determine the total medical costs for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The mean total costs per patient at 2 years of follow-up were €26,399. These results contribute to cost awareness. The absolute number of hip fractures is rising and increases the already significant burden on society. The aim of this study was to determine the mean total medical costs per patient for treating displaced femoral neck fractures with hemi- or total hip arthroplasty in fit elderly patients. The population was the Dutch sample of an international randomized controlled trial consisting of femoral neck fracture patients treated with hemi- or total hip arthroplasty. Patient data and health care utilization were prospectively collected during a total follow-up period of 2 years. Costs were separated into costs for hospital care during primary stay, hospital costs for clinical follow-up, and costs generated outside the hospital during rehabilitation. Multiple imputations were used to account for missing data. Data of 141 participants (mean age 81 years) were included in the analysis. The 2-year mortality rate was 19 %. The mean total cost per patient after 10 weeks of follow-up was €15,216. After 1 and 2 years of follow-up the mean total costs were €23,869 and €26,399, respectively. Rehabilitation was the main cost determinant, and accounted for 46 % of total costs. Primary hospital admission days accounted for 22 % of the total costs, index surgery for 11 %, and physical therapy for 7 %. The main cost determinants for hemi- or total hip arthroplasty after treatment of displaced femoral neck fractures (€26,399 per patient until 2 years) were rehabilitation and nursing homes. Most of the costs were made in the first year. Reducing costs after hip fracture surgery should focus on improving the duration and efficiency of the rehabilitation phase.

  11. Pre-fracture individual characteristics associated with high total health care costs after hip fracture.

    PubMed

    Schousboe, J T; Paudel, M L; Taylor, B C; Kats, A M; Virnig, B A; Dowd, B E; Langsetmo, L; Ensrud, K E

    2017-03-01

    Older women with pre-fracture slow walk speed, high body mass index, and/or a high level of multimorbidity have significantly higher health care costs after hip fracture compared to those without those characteristics. Studies to investigate if targeted health care interventions for these individuals can reduce hip fracture costs are warranted. The aim of this study is to estimate the associations of individual pre-fracture characteristics with total health care costs after hip fracture, using Study of Osteoporotic Fractures (SOF) cohort data linked to Medicare claims. Our study population was 738 women age 70 and older enrolled in Medicare Fee for Service (FFS) who experienced an incident hip fracture between January 1, 1992 and December 31, 2009. We assessed pre-fracture individual characteristics at SOF study visits and estimated costs of hospitalizations, skilled nursing facility and inpatient rehabilitation stays, home health care visits, and outpatient utilization from Medicare FFS claims. We used generalized linear models to estimate the associations of predictor variables with total health care costs (2010 US dollars) after hip fracture. Median total health care costs for 1 year after hip fracture were $35,536 (inter-quartile range $24,830 to $50,903). Multivariable-adjusted total health care costs for 1 year after hip fracture were 14 % higher ($5256, 95 % CI $156 to $10,356) in those with walk speed <0.6 m/s compared to ≥1.0 m/s, 25 % higher ($9601, 95 % CI $3314 to $16,069) in those with body mass index ≥30 kg/m 2 compared to 20 to 24.9 mg/kg 2 , and 21 % higher ($7936, 95 % CI $346 to $15,526) for those with seven or more compared to no comorbid medical conditions. Pre-fracture poor mobility, obesity, and multiple comorbidities are associated with higher total health care costs after hip fracture in older women. Studies to investigate if targeted health care interventions for these individuals can reduce the costs of hip fractures are warranted.

  12. Revision hip preservation surgery with hip arthroscopy: clinical outcomes.

    PubMed

    Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J

    2014-05-01

    To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P < .0001). The visual analog scale score improved from 7.3 ± 1.5 to 3.9 ± 2.5 (P < .0001). Improvements in the Non-Arthritic Hip Score of at least 10 points and 20 points were found in 28 hips (65%) and 19 hips (44%), respectively. Four hips in 3 patients required conversion to total hip arthroplasty. Positive predictive factors for PRO improvement were previous open surgery, pincer impingement, cam impingement, symptomatic heterotopic ossification, and segmental labral defects treated with labral reconstruction. On the basis of multiple PROs, revision hip preservation with hip arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model.

    PubMed

    Barlow, Brian T; McLawhorn, Alexander S; Westrich, Geoffrey H

    2017-05-03

    Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $1,023, and the cost-effectiveness threshold for DM implants was $5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components. Economic and decision analysis Level III. See Instructions for Authors for a complete description of levels of evidence.

  14. Cemented Total Hip Replacement Cable Debris and Acetabular Construct Durability

    PubMed Central

    Altenburg, Aaron J.; Callaghan, John J.; Yehyawi, Tameem M.; Pedersen, Douglas R.; Liu, Steve S.; Leinen, Jessica A.; Dahl, Kevin A.; Goetz, Devon D.; Brown, Thomas D.; Johnston, Richard C.

    2009-01-01

    Background: Third-body wear can adversely affect the outcome of total hip arthroplasty by causing increased polyethylene wear, osteolysis, and component loosening. We hypothesized that there would be greater generation and migration of metal debris to the bearing surfaces in hips in which cobalt-chromium cables were used to reattach the osteotomized greater trochanter when compared with hips in which stainless steel wires were used. Methods: Between June 1981 and December 1983, 196 consecutive total hip arthroplasties were performed with use of an Iowa stem and a titanium-backed cemented acetabular component, with cobalt-chromium cable trochanteric reattachment. After nineteen to twenty years of follow-up, the patients were evaluated with regard to the depth of head penetration into the polyethylene (as a surrogate for wear), osteolysis, loosening, and the need for revision. The results were compared with those for a series of 304 total hip arthroplasties that were performed by the same surgeon from January 1984 to December 1985 with use of the same components and the same surgical technique, but with stainless steel wire trochanteric reattachment. The two groups had a comparable nineteen to twenty-year follow-up. All living patients (fifty-nine hips in the cable group and ninety-two hips in the wire group) had minimum ten-year follow-up radiographs. Results: The polyethylene wear rate was 0.101 mm/yr for the cable group and 0.082 mm/yr for the wire group (p = 0.039). For the living patients, the rate of revision of the acetabular component because of aseptic loosening was 37.3% (twenty-two hips) for the cable group and 20.7% (nineteen hips) for the wire group (p = 0.025). The rate of acetabular osteolysis was 44% (twenty-six hips) for the cable group and 26% (twenty-four hips) for the wire group (p = 0.022). Kaplan-Meier analysis with revision of the acetabular component because of aseptic loosening as the end point demonstrated survival rates of 73.7% ± 9% and 83% ± 7% for the cable and wire groups, respectively, at twenty years (p = 0.03). Conclusions: Because cable trochanteric attachment led to significantly greater polyethylene wear, osteolysis, acetabular loosening, and acetabular revision, presumably due to third-body metallic debris generation in this cemented total hip replacement construct, surgeons should be aware of the deleterious effects of third-body debris and avoid the use of potential debris generators in the total hip arthroplasty construct. If cable is used and fretting is recognized, especially with intra-articular migration of metallic material or nonunion of the greater trochanter, consideration should be given to cable removal. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence. PMID:19571089

  15. Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty

    PubMed Central

    Wu, Guo-Liang; Zhu, Wei; Zhao, Yan; Ma, Qi; Weng, Xi-Sheng

    2016-01-01

    Objective: The present study aimed to review the characteristics and influencing factors of squeaking after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) and to analyze the possible mechanisms of the audible noise. Data Sources: The data analyzed in this review were based on articles from PubMed and Web of Science. Study Selection: The articles selected for review were original articles and reviews found based on the following search terms: “total hip arthroplasty”, “ceramic-on-ceramic”, “hip squeaking”, and “hip noise.” Results: The mechanism of the squeaking remains unknown. The possible explanations included stripe wear, edge loading, a third body, fracture of the ceramic liner, and resonance of the prosthesis components. Squeaking occurrence is influenced by patient, surgical, and implant factors. Conclusions: Most studies indicated that squeaking after CoC THA was the consequence of increasing wear or impingement, caused by prosthesis design, patient characteristics, or surgical factors. However, as conflicts exist among different articles, the major reasons for the squeaking remain to be identified. PMID:27453238

  16. Evaluation of Hip Internal and External Rotation Range of Motion as an Injury Risk Factor for Hip, Abdominal and Groin Injuries in Professional Baseball Players

    PubMed Central

    Ma, Richard; Zhou, Hanbing; Thompson, Matthew; Dawson, Courtney; Nguyen, Joseph; Coleman, Struan

    2015-01-01

    Normal hip range of motion (ROM) is essential in running and transfer of energy from lower to upper extremities during overhead throwing. Dysfunctional hip ROM may alter lower extremity kinematics and predispose athletes to hip and groin injuries. The purpose of this study is characterize hip internal/external ROM (Arc) and its effect on the risk of hip, hamstring, and groin injuries in professional baseball players. Bilateral hip internal and external ROM was measured on all baseball players (N=201) in one professional organization (major and minor league) during spring training. Players were organized according to their respective positions. All injuries were documented prospectively for an entire MLB season (2010 to 2011). Data was analyzed according to position and injuries during the season. Total number of players (N=201) with an average age of 24±3.6 (range=17-37). Both pitchers (N=93) and catchers (N=22) had significantly decreased mean hip internal rotation and overall hip arc of motion compared to the positional players (N=86). Players with hip, groin, and hamstring injury also had decreased hip rotation arc when compared to the normal group. Overall, there is a correlation between decreased hip internal rotation and total arc of motion with hip, hamstring, and groin injuries. PMID:26793294

  17. Invariant hip moment pattern while walking with a robotic hip exoskeleton

    PubMed Central

    Lewis, Cara L.; Ferris, Daniel P.

    2011-01-01

    Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 minutes of the powered condition and the unpowered condition. After completing three 30-minute training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. PMID:21333995

  18. Frost decreases content of sugars, ascorbic acid and some quercetin glycosides but stimulates selected carotenes in Rosa canina hips.

    PubMed

    Cunja, Vlasta; Mikulic-Petkovsek, Maja; Zupan, Anka; Stampar, Franci; Schmitzer, Valentina

    2015-04-15

    Primary and secondary metabolites of Rosa canina hips were determined by HPLC/MS during ripening and after frost damage. Rose hips were harvested six times from the beginning of September until the beginning of December. Color parameters a*, b* and L* decreased during maturation. Glucose and fructose were the predominant sugars representing up to 92% total sugars, and citric acid was the major organic acid detected in rose hips (constituting up to 58% total organic acids). Total sugar and ascorbic acid content significantly decreased after frost damage; from 42.2 to 25.9 g 100 g(-1) DW for sugars and from 716.8 to 176.0 mg 100 g(-1) DW for ascorbic acid. Conversely, β-carotene and lycopene levels increased in frostbitten rose hips to 22.1 and 113.2 mg 100 g(-1) DW, respectively. In addition to cyanidin-3-glucoside (highest level in hips was 125.7 μg 100 g (-1) DW), 45 different phenolic compounds have been identified. The most abundant were proanthocyanidins (their levels amounted up to 90% of total flavanol content) and their content showed no significant differences during maturation. The levels of catechin, phloridzin, flavanones and several quercetin glycosides were highest on the first three sampling dates and decreased after frost. Antioxidant capacity similarly decreased in frostbitten rose hips. Total phenolic content increased until the third sampling and decreased on later samplings. Copyright © 2015 Elsevier GmbH. All rights reserved.

  19. A prospective randomised study comparing the jubilee dressing method to a standard adhesive dressing for total hip and knee replacements.

    PubMed

    Burke, Neil G; Green, Connor; McHugh, Gavin; McGolderick, Niall; Kilcoyne, Carol; Kenny, Patrick

    2012-08-01

    It is important to reduce potential wound complications in total hip and total knee arthroplasty procedures. The purpose of this study was to compare the jubilee dressing method to a standard adhesive dressing. 124 patients (62 total hip replacements and 62 total knee replacements) were randomly selected to have either a standard adhesive dressing or jubilee method dressing. The number of dressing changes, incidence of blistering, leakage, appearance of inflammation, infection rate and the average stay in hospital was recorded for each patient. The jubilee dressing significantly reduced the rate of blistering, leakage and number of dressing changes when compare to a traditional adhesive dressing (p < 0.05). The rate of inflammation and average length of stay in hospital was not significantly different between the two groups. The authors recommend the use of this dressing for total hip and total knee arthroplasty procedures due to the associated lower complication rate. Copyright © 2012 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  20. Transfusions and blood loss in total hip and knee arthroplasty: a prospective observational study.

    PubMed

    Carling, Malin S; Jeppsson, Anders; Eriksson, Bengt I; Brisby, Helena

    2015-03-28

    There is a high prevalence of blood product transfusions in orthopedic surgery. The reported prevalence of red blood cell transfusions in unselected patients undergoing hip or knee replacement varies between 21% and 70%. We determined current blood loss and transfusion prevalence in total hip and knee arthroplasty when tranexamic acid was used as a routine prophylaxis, and further investigated potential predictors for excessive blood loss and transfusion requirement. In total, 193 consecutive patients undergoing unilateral hip (n = 114) or knee arthroplasty (n = 79) were included in a prospective observational study. Estimated perioperative blood loss was calculated and transfusions of allogeneic blood products registered and related to patient characteristics and perioperative variables. Overall transfusion rate was 16% (18% in hip patients and 11% in knee patients, p = 0.19). Median estimated blood loss was significantly higher in hip patients (984 vs 789 mL, p < 0.001). Preoperative hemoglobin concentration was the only independent predictor of red blood cell transfusion in hip patients while low hemoglobin concentration, body mass index, and operation time were independent predictors for red blood cell transfusion in knee patients. The prevalence of red blood cell transfusion was lower than previously reported in unselected total hip or knee arthroplasty patients. Routine use of tranexamic acid may have contributed. Low preoperative hemoglobin levels, low body mass index, and long operation increase the risk for red blood cell transfusion.

  1. Metal-on-Metal Total Hip Resurfacing Arthroplasty: An Evidence-Based Analysis.

    PubMed

    2006-01-01

    The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large femoral head reduces the chance of dislocation, so that rates of dislocation are less than those with conventional THR. Second, the range of motion with hip resurfacing arthroplasty is higher than that achieved with conventional THR. A variety of MOM hip resurfacing implants are used in clinical practice. Six MOM hip resurfacing implants have been issued licences in Canada. A search of electronic bibliographies (OVID Medline, Medline In-Process and Other Non-Indexed Citations, Embase, Cochrane CENTRAL and DSR, INAHTA) was undertaken to identify evidence published from Jan 1, 1997 to October 27, 2005. The search was limited to English-language articles and human studies. The literature search yielded 245 citations. Of these, 11 met inclusion criteria (9 for effectiveness, 2 for safety). The result of the only reported randomized controlled trial on MOM hip resurfacing arthroplasty could not be included in this assessment, because it used a cemented acetabular component, whereas in the new generation of implants, a cementless acetabular component is used. After omitting this publication, only case series remained.   HEALTH OUTCOMES: The Harris hip score and SF-12 are 2 measures commonly used to report health outcomes in MOM hip resurfacing arthroplasty studies. Other scales used are the Oxford hip score and the University of California Los Angeles hip score. The case series showed that the mean revision rate of MOM hip resurfacing arthroplasty is 1.5% and the incidence of femoral neck fracture is 0.67%. Across all studies, 2 cases of osteonecrosis were reported. Four studies reported improvement in Harris hip scores. However, only 1 study reported a statistically significant improvement. Three studies reported improvement in SF-12 scores, of which 2 reported a significant improvement. One study reported significant improvement in UCLA hip score. Two studies reported postoperative Oxford hip scores, but no preoperative values were reported. None of the reviewed studies reported procedure-related deaths. Four studies reported implant survival rates ranging from 94.4% to 99.7% for a follow-up period of 2.8 to 3.5 years. Three studies reported on the range of motion. One reported improvement in all motions including flexion, extension, abduction-adduction, and rotation, and another reported improvement in flexion. Yet another reported improvement in range of motion for flexion abduction-adduction and rotation arc. However, the author reported a decrease in the range of motion in the arc of flexion in patients with Brooker class III or IV heterotopic bone (all patients were men). SAFETY OF METAL-ON-METAL HIP RESURFACING ARTHROPLASTY: There is a concern about metal wear debris and its systemic distribution throughout the body. Detectable metal concentrations in the serum and urine of patients with metal hip implants have been described as early as the 1970s, and this issue is still controversial after 35 years. Several studies have reported high concentration of cobalt and chromium in serum and/or urine of the patients with metal hip implants. Potential toxicological effects of the elevated metal ions have heightened concerns about safety of MOM bearings. This is of particular concern in young and active patients in whom life expectancy after implantation is long. Since 1997, 15 studies, including 1 randomized clinical trial, have reported high levels of metal ions after THR with metal implants. Some of these studies have reported higher metal levels in patients with loose implants. Because patients who receive a MOM hip arthroplasty are shown to be exposed to high concentrations of metallic ions, the Medical Advisory Secretariat searched the literature for reports of adverse biological effects of cobalt and chromium. Cobalt and chromium make up the major part of the metal articulations; therefore, they are a focus of concern. To date, only one study has examined the incidence of cancer after MOM and polyethylene on metal total hip arthroplasties. The results were compared to that of general population in Finland. The mean duration of follow-up for MOM arthroplasty was 15.7 years; for polyethylene arthroplasty, it was 12.5 years. The standardized incidence ratio for all cancers in the MOM group was 0.95 (95% CI, 0.79-1.13). In the polyethylene on metal group it was 0.76 (95% CI, 0.68-0.86). The combined standardized incidence ratio for lymphoma and leukemia in the patients who had MOM THR was 1.59 (95% CI, 0.82-2.77). It was 0.59 (95% CI, 0.29-1.05) for the patients who had polyethylene on metal THR. Patients with MOM THR had a significantly higher risk of leukemia. All patients who had leukemia were aged over than 60 years.   EPIDEMIOLOGICAL STUDIES OF MYOCARDIOPATHY OF BEER DRINKERS: An unusual type of myocardiopathy, characterized by pericardial effusion, elevated hemoglobin concentrations, and congestive heart failure, occurred as an epidemic affecting 48 habitual beer drinkers in Quebec City between 1965 and 1966. This epidemic was directly related the consumption of a popular beer containing cobalt sulfate. The epidemic appeared 1 month after cobalt sulfate was added to the specific brewery, and no further cases were seen a month after this specific chemical was no longer used in making this beer. A beer of the same name is made in Montreal, and the only difference at that time was that the Quebec brand of beer contained about 10 times more cobalt sulphate. Cobalt has been added to some Canadian beers since 1965 to improve the stability of the foam but it has been added in larger breweries only to draught beer. However, in small breweries, such as those in Quebec City, separate batches were not brewed for bottle and draught beer; therefore, cobalt was added to all of the beer processed in this brewery. In March 1966, a committee was appointed under the chairmanship of the Deputy Minister of Health for Quebec that included members of the department of forensic medicine of Quebec's Ministry of Justice, epidemiologists, members of Food and Drug Directorate of Ottawa, toxicologists, biomedical researchers, pathologists, and members of provincial police. Epidemiological studies were carried out by the Provincial Ministry of Health and the Quebec City Health Department. The association between the development of myocardiopathy and the consumption of the particular brand of beer was proven. The mortality rate of this epidemic was 46.1% and those who survived were desperately ill, and recovered only after a struggle for their lives. Similar cases were seen in Omaha (Nebraska). The epidemic started after a cobalt additive was used in 1 of the beers marketed in Nebraska. Sixty-four patients with the clinical diagnosis of alcoholic myocardiopathy were seen during an 18-month period (1964-1965). Thirty of these patients died. The first patient became ill within 1 month after cobalt was added to the beer, and the last patient was seen within 1 month of withdrawal of cobalt. A similar epidemic occurred in Minneapolis, Minnesota. Between 1964 and 1967, 42 patients with acute heart failure were admitted to a hospital in Minneapolis, Minnesota. Twenty of these patients were drinking 6 to 30 bottles per day of a particular brand of beer exclusively. The other 14 patients also drank the same brand of beer, but not exclusively. The mortality rate from the acute illness was 18%, but late deaths accounted for a total mortality rate of 43%. Examination of the tissue from these patients revealed markedly abnormal changes in myofibrils (heart muscles), mitochondria, and sarcoplasmic reticulum. In Belgium, a similar epidemic was reported in 1966, in which, cobalt was used in some Belgian beers. (ABSTRACT TRUNCATED)

  2. Safety measures in hip arthroscopy and their efficacy in minimizing complications: a systematic review of the evidence.

    PubMed

    Gupta, Asheesh; Redmond, John M; Hammarstedt, Jon E; Schwindel, Leslie; Domb, Benjamin G

    2014-10-01

    The purpose of this systematic review was to evaluate the literature to determine complications of hip arthroscopy, with a secondary focus on how to minimize complications and risks. Two independent reviewers performed a search of PubMed for articles that contained at least 1 of the following terms: complications and hip arthroscopy, hip impingement, femoral acetabular impingement and complications, or femoroacetabular impingement (FAI) and complications. The search was limited to articles published between 1999 and June 2013. An additional search was performed for articles evaluating techniques on how to minimize complications. We identified 81 studies (5,535 patients; 6,277 hips). The mean age was 35.48 years, and the mean body mass index was 25.20 kg/m(2). Of the participants, 52% were male and 48% were female. The majority of studies were Level IV Evidence (63%). A total of 285 complications were reported, for an overall rate of 4.5%. There were 26 major complications (0.41%) and a 4.1% minor complication rate. The overall reoperation rate was 4.03%. A total of 94 hips underwent revision arthroscopy. Regarding open procedures, 150 patients (93%) underwent either total hip arthroplasty or a hip resurfacing procedure. The conversion rate to total hip arthroplasty or a resurfacing procedure was 2.4%. Overall, primary hip arthroscopy is a successful procedure with low rates of major (0.41%) and minor (4.1%) complications. The reoperation rate was 4.03% in our review. There is admittedly a learning curve to performing hip arthroscopy, and we present a systematic review of the complications and how to minimize these complications with careful technique and planning. Level IV, systematic review of Level II to V studies. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  3. [Total hip arthroplasty through anterior "minimal invasive" approach].

    PubMed

    Moerenhout, Kevin G; Cherix, Stéphane; Rüdiger, Hannes A

    2012-12-19

    Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.

  4. Digital versus analogue preoperative planning of total hip arthroplasties: a randomized clinical trial of 210 total hip arthroplasties.

    PubMed

    The, Bertram; Verdonschot, Nico; van Horn, Jim R; van Ooijen, Peter M A; Diercks, Ron L

    2007-09-01

    The objective of this randomized clinical trial was to compare the clinical and technical results of digital preoperative planning for primary total hip arthroplasties with analogue planning. Two hundred and ten total hip arthroplasties were randomized. All plans were constructed on standardized radiographs by the surgeon who performed the arthroplasty the next day. The main outcome was accuracy of the preoperative plan. Secondary outcomes were operation time and a radiographic assessment of the arthroplasty. Digital preoperative plans were more accurate in planning the cup (P < .05) and scored higher on the postoperative radiologic assessment of cemented cup (P = .03) and stem (P < .01) components. None of the other comparisons reached statistical significance. We conclude that digital plans slightly outperform analogue plans.

  5. [Local infiltration analgesia in total joint replacement].

    PubMed

    de Jonge, Tamás; Görgényi, Szabolcs; Szabó, Gabriella; Torkos, Miklós Bulcsú

    2017-03-01

    Total hip and knee replacment surgeries are characterized by severe postoperative pain. Local infiltration analgesia is proved to be very effective. However this method has not been widely used in Hungary. To evaluate the efficacy of the local infiltration analgesia with modified components in patients underwent total hip or knee replacement surgery. Data of 99 consecutive patients underwent primary total hip or knee replacement surgery were evaluated prospectively. In all the 99 surgeries modified local infiltration analgesia was applied. Postoperative pain reported on a visual analog scale was recorded as well as the need for further analgetics during the first 18 hours after surgery. The cost of the analgetic drugs was calculated. The control group comprised 97 consecutive patients underwent total hip or knee replacement, where local infiltration analgesia was not applied. Statistical analysis was done. Patients received local infiltration analgesia reported significantly less pain (p<0.001). The need for postoperatively given analgetics was almost 50% less, and the cost of all postoperative analgetics was 47% less than in the control group. In total hip and knee replacement surgeries the modified local infiltration analgesia decreases postoperative pain effectively and contribute to the early mobilization of the patients. Orv. Hetil., 2017, 158(9), 352-357.

  6. The effect of unilateral osteoarthritis of the hip on postural balance disorders.

    PubMed

    Truszczyńska, Aleksandra; Trzaskoma, Zbigniew; Białecki, Jerzy; Drzał-Grabiec, Justyna; Dadura, Emilia; Rąpała, Kazimierz; Tarnowski, Adam

    2016-11-10

    Postural stability is of great importance because imbalances and muscle weakness are significant risk factors for falls experienced by the elderly. Hip arthrosis, which causes pain and gait disorders that affect balance control, is common in the ageing population. The aim of this study was to assess postural stability in patients with unilateral hip arthrosis before total hip arthroplasty. The study population consisted of 52 patients with hip arthrosis (study group) and 47 subjects with no history of clinical symptoms of hip pain. The groups did not differ statistically in terms of age and BMI. Static balance was assessed by conducting a quantitative analysis of balance reaction parameters in a quiet standing position with the eyes open and closed. Analysis of the collected data revealed numerous statistically significant differences between patients with unilateral hip arthrosis before total hip arthoplasty and the asymptomatic group for parameters tested with eyes closed (p<0.05). We observed higher values of total length of centre of pressure (COP), sway path (SP), length of COP path in the medial-lateral plane (SPML), maximal amplitude between the 2 most distant points in the medial-lateral plane (MaxML), mean COP velocity (MV), and mean COP velocity in medial-lateral (MVML) in the study group.

  7. A comparative analysis of warfarin and low-dose heparin as thromboembolism prophylaxis in total hip replacement patinets.

    PubMed Central

    Ritter, M A; HamiltonCW

    1975-01-01

    Warfarin, low-dose heparin, or a combination of low-dose heparin and hydrocortisone was administered to 300 patients undergoing total hip replacement. The lowest incidence of thromboembolic (5 per cent) was attained with Warfarin. Further investigation into the method of administration of low-dose heparin is necessary before it can be used effectively as thromboembolism prophylaxis in total hip replacement patients. The addition of hydrocortisone was not found useful. PMID:1138642

  8. Relationship between Physical Impairments and Movement Patterns During Gait in Patients With End-stage Hip Osteoarthritis

    PubMed Central

    Zeni, Joseph; Pozzi, Federico; Abujaber, Sumayah; Miller, Laura

    2014-01-01

    Patients with hip osteoarthritis demonstrate limited range of motion, muscle weakness and altered biomechanics; however, few studies have evaluated the relationships between physical impairments and movement asymmetries. The purpose of this study was to identify the physical impairments related to movement abnormalities in patients awaiting total hip arthroplasty. We hypothesized that muscle weakness and pain would be related to greater movement asymmetries. Fifty-six subjects who were awaiting total hip arthroplasty were enrolled. Pain was assessed using a 0 to 10 scale, range of motion was assessed with the Harris Hip Score and isometric hip abductor strength was tested using a hand-held dynamometer. Trunk, pelvis and hip angles and moments in the frontal and sagittal planes were measured during walking using three dimensional motion analysis. During gait, subjects had 3.49 degrees less peak hip flexion and 8.82 degrees less extension angles (p<0.001) and had 0.03 Nm/k*m less hip abduction moment on the affected side (p=0.043). Weaker hip muscles were related to greater pelvis (r=−0.291) and trunk (r=−0.332) rotations in the frontal plane. These findings suggest that hip weakness drives abnormal movement patterns at the pelvis and trunk in patients with hip osteoarthritis to a greater degree than hip pain. PMID:25492583

  9. Hip and knee replacement in osteogenesis imperfecta.

    PubMed

    Papagelopoulos, P J; Morrey, B F

    1993-04-01

    Five total hip and three total knee arthroplasties were performed, from 1969 to 1990, in six patients who had osteogenesis imperfecta. The patients who had a hip arthroplasty were followed for a mean of seven years, and those who had a knee arthroplasty, for a mean of ten years. Postoperatively, all had relief of pain and were able to walk; one patient used a walker and two used a cane. The only postoperative complication was an intrapelvic protrusion of the acetabular component six years after a bipolar hip replacement.

  10. Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study.

    PubMed

    McLean, Robert R; Kiel, Douglas P; Berry, Sarah D; Broe, Kerry E; Zhang, Xiaochun; Cupples, L Adrienne; Hannan, Marian T

    2018-01-05

    Although muscle mass influences strength in older adults, it is unclear whether low lean mass measured by dual-energy X-ray absorptiometry (DXA) is an independent risk factor for hip fracture. Our objective was to determine the association between DXA lean mass and incident hip fracture risk among 1978 women aged 50 years and older participating in the Framingham Study Original and Offspring cohorts. Leg and total body lean mass (kg) were assessed from whole-body DXA scans collected in 1992-2001. Hip fracture follow-up extended from DXA assessment to the occurrence of fracture, death, drop-out, or end of follow-up in 2007. Cox proportional hazards regression was used to calculate hazard ratios (HR) and 95% confidence intervals (CI) estimating the relative risk of hip fracture associated with a 1-kg increase in baseline lean mass. Mean age was 66 years (range 50-93). Over a median of 8 years of follow-up, 99 hip fractures occurred. In models adjusted for age, height, study cohort, and percent total body fat, neither leg (HR 1.11; 95% CI 0.94, 1.31) nor total body (HR 1.06; 95% CI 0.99, 1.13) lean mass were associated with hip fracture. After further adjustment for femoral neck bone mineral density, leg lean mass results were similar (HR 1.10; 95% CI 0.93, 1.30). In contrast, 1 kg greater total body lean mass was associated with 9% higher hip fracture risk (HR 1.09; 95% CI 1.02, 1.18). Our findings suggest that in women, lower lean mass measured by DXA is not associated with increased risk of hip fracture.

  11. The Cost of Joint Replacement: Comparing Two Approaches to Evaluating Costs of Total Hip and Knee Arthroplasty.

    PubMed

    Palsis, John A; Brehmer, Thomas S; Pellegrini, Vincent D; Drew, Jacob M; Sachs, Barton L

    2018-02-21

    In an era of mandatory bundled payments for total joint replacement, accurate analysis of the cost of procedures is essential for orthopaedic surgeons and their institutions to maintain viable practices. The purpose of this study was to compare traditional accounting and time-driven activity-based costing (TDABC) methods for estimating the total costs of total hip and knee arthroplasty care cycles. We calculated the overall costs of elective primary total hip and total knee replacement care cycles at our academic medical center using traditional and TDABC accounting methods. We compared the methods with respect to the overall costs of hip and knee replacement and the costs for each major cost category. The traditional accounting method resulted in higher cost estimates. The total cost per hip replacement was $22,076 (2014 USD) using traditional accounting and was $12,957 using TDABC. The total cost per knee replacement was $29,488 using traditional accounting and was $16,981 using TDABC. With respect to cost categories, estimates using traditional accounting were greater for hip and knee replacement, respectively, by $3,432 and $5,486 for personnel, by $3,398 and $3,664 for space and equipment, and by $2,289 and $3,357 for indirect costs. Implants and consumables were derived from the actual hospital purchase price; accordingly, both methods produced equivalent results. Substantial cost differences exist between accounting methods. The focus of TDABC only on resources used directly by the patient contrasts with the allocation of all operating costs, including all indirect costs and unused capacity, with traditional accounting. We expect that the true costs of hip and knee replacement care cycles are likely somewhere between estimates derived from traditional accounting methods and TDABC. TDABC offers patient-level granular cost information that better serves in the redesign of care pathways and may lead to more strategic resource-allocation decisions to optimize actual operating margins.

  12. Inter- and intra-observer variability of radiography and computed tomography for evaluation of Zurich cementless acetabular cup placement ex vivo.

    PubMed

    Leasure, Jessica O; Peck, Jeffrey N; Villamil, Armando; Fiore, Kara L; Tano, Cheryl A

    2016-11-23

    To evaluate the inter- and intra-observer variability in measurement of the angle of lateral opening (ALO) and version angle measurement using digital radiography and computed tomography (CT). Each hemipelvis was implanted with a cementless acetabular cup. Ventrodorsal and mediolateral radiographs were made of each pelvis, followed by CT imaging. After removal of the first cup, the pelves were implanted with an acetabular cup in the contralateral acetabulum and imaging was repeated. Three surgeons measured the ALO and version angles three times for each cup from the mediolateral radiographic projection. The same measurements were made using three-dimensional multiplanar reconstructions from CT images. Two anatomical axes were used to measure pelvic inclination in the sagittal plane, resulting in six measurements per cup. Two-way repeated measures analysis of variance evaluated inter- and intra-observer repeatability for radiographic and CT-based measurements. Version angle based on radiographic measurement did not differ within surgeons (p = 0.433), but differed between surgeons (p <0.001). Radiographic measurement of ALO differed within surgeons (p = 0.006) but not between surgeons (p = 0.989). The ALO and version angle measured on CT images did not differ with or between surgeons. Assessment of inter- and intra-observer measurement of ALO and version angle was more reproducible using CT images than conventional mediolateral radiography for a Zurich cementless acetabular cup.

  13. The effect of stem design on the prevalence of squeaking following ceramic-on-ceramic bearing total hip arthroplasty.

    PubMed

    Restrepo, Camilo; Post, Zachary D; Kai, Brandon; Hozack, William J

    2010-03-01

    The ceramic-on-ceramic bearing for total hip arthroplasty has an extremely low wear rate and demonstrates minimal inflammatory response in comparison with other bearing choices. However, acoustic emissions such as squeaking and clicking are being reported as annoying complications related to its use. The cause or causes of this phenomenon have not been determined. The purpose of the present study was to evaluate the possibility that design aspects of the femoral component may be a contributing factor to the etiology of squeaking associated with the ceramic-on-ceramic bearing total hip arthroplasty. We retrospectively reviewed 266 consecutive patients (304 hips) who had undergone total hip arthroplasty with use of ceramic-on-ceramic bearings. The first 131 consecutive patients (152 hips) (Group 1) received a hydroxyapatite-coated stem composed of titanium-aluminum-vanadium alloy with a C-taper neck geometry and robust midsection with an anteroposterior diameter of 13 mm. The second 135 consecutive patients (152 hips) (Group 2) also received a hydroxyapatite-coated stem, but in that group the stem was composed of titanium-molybdenum-zirconium-iron alloy, with a V-40 neck geometry and a midsection with an anteroposterior thickness of only 10 mm. All 304 hips received the same cup, composed of titanium-aluminum-vanadium alloy. Demographic characteristics, such as age, sex, height, weight, and body mass index, were similar in both groups. Data regarding the presence of squeaking were obtained prospectively. Patients who were seen for clinical follow-up either expressed the squeaking phenomenon themselves or were asked about it by the physician. Patients who were not seen at a recent clinical follow-up visit were contacted by telephone and were asked specifically about squeaking that might be associated with the hip replacement. Only patients with confirmed squeaking noise were included in the present study. Postoperative radiographs, the Short Form-36 health survey, the Harris hip score, and office or telephone interviews of the patient were used to determine the overall outcome of the procedure. The prevalence of squeaking was seven times higher for patients who received the titanium-molybdenum-zirconium-iron-alloy stem (twenty-seven patients, twenty-eight hips [18.4%]) than in those who received the titanium-aluminum-vanadium-alloy stem (three patients, four hips [2.6%]); this difference was significant (p < 0.0001). Our study suggests that different stem alloys, stem geometries, or neck geometries can have an impact on the frequency of squeaking following a ceramic-on-ceramic total hip arthroplasty.

  14. Contemporary Strategies for Rapid Recovery Total Hip Arthroplasty.

    PubMed

    Stambough, Jeffrey B; Beaulé, Paul E; Nunley, Ryan M; Clohisy, John

    2016-01-01

    Over the past several years, rapid recovery protocols for total hip arthroplasty have evolved in parallel with advancements in pain management, regional anesthesia, focused rehabilitation, and the patient selection process. As fiscal pressures from payers of health care increase, surgical outcomes and complications are being scrutinized, which evokes a sense of urgency for arthroplasty surgeons as well as hospitals. The implementation of successful accelerated recovery pathways for total hip arthroplasty requires the coordinated efforts of surgeons, practice administrators, anesthesiologists, nurses, physical and occupational therapists, case managers, and postacute care providers. To optimize performance outcomes, it is important for surgeons to select patients who are eligible for rapid recovery. The fundamental tenets of multimodal pain control, regional anesthesia, prudent perioperative blood management, venous thromboembolic prophylaxis, and early ambulation and mobility should be collectively addressed for all patients who undergo primary total hip replacement.

  15. Manual therapy intervention for a patient with a total hip arthroplasty revision.

    PubMed

    Howard, Paul D; Levitsky, Beth

    2007-12-01

    Case report. A 73-year-old active woman with a total hip arthroplasty, who later had revision surgery, developed left hip and buttock pain 2 years after the revision surgery, subsequent to lifting her foot while seated. This movement was performed so that her spouse could assist her in putting on her sock and shoe. During the first physical therapy session, the patient exhibited a forward-flexed trunk posture and difficulty weight bearing on the involved lower limb. The patient was successfully treated with manual therapy techniques and a home exercise program. The manual therapy techniques included long-axis hip distraction, lateral hip distraction, posterior-to-anterior hip joint mobilization, and a contract-relax proprioceptive neuromuscular facilitation technique. The patient's home program consisted of long-axis hip distraction, performed by her spouse, and standing lower limb pendular movements into flexion and extension. Pain scale ratings, posture and gait observations, strength, range of motion, and return to functional activities served as outcome measures. After 1 physical therapy visit, in which manual therapy techniques were utilized, the patient had a significant decrease in hip symptoms. The patient and spouse were compliant with the home exercise program and continued with physical therapy for 3 more visits, and the patient ultimately became symptom free. The patient returned to all previous activities, including household chores, cooking, and a walking program. The patient was contacted at 6 months, 1 year, and 4 years, and reported no recurrences of hip or buttock symptoms. Manual therapy techniques and home exercises described in this case report were apparently effective in eliminating symptoms and returning this patient, who had total hip arthroplasty and revision surgery 2 years earlier, to all previous functional activities after a dressing incident produced hip and buttock symptoms.

  16. Calcaneal stress fracture: an adverse event following total hip and total knee arthroplasty: a report of five cases.

    PubMed

    Miki, Takaaki; Miki, Takahito; Nishiyama, Akihiro

    2014-01-15

    Stress fractures have been reported to occur in the pubis, femoral neck, proximal part of the tibia, and fabella during the postoperative period following total knee or total hip arthroplasty. However, to our knowledge, calcaneal stress fractures after total hip or total knee arthroplasty have not been reported in the English-language literature. Most orthopaedic surgeons are not familiar with calcaneal stress fractures that may occur in elderly patients after a total knee or total hip arthroplasty. We retrospectively reviewed the clinical features, imaging findings, and bone mineral content of the proximal part of the femur and the distal end of the radius in five patients who had a calcaneal stress fracture after a total knee or total hip arthroplasty. All patients were women with a mean age of 76.8 years. All fractures occurred in the calcaneus on the same side as the arthroplasty. The fracture appeared at a mean of 10.2 weeks postoperatively. All patients reported heel pain on walking. Swelling and local heat were found in four and three patients, respectively. Pain was elicited by squeezing the calcaneus in all patients. Early radiographs had normal findings in two patients, and an irregular sclerotic line appeared later in the radiographs of all patients. All fractures were treated conservatively. Four fractures healed uneventfully, but one fracture displaced. All patients had osteoporosis. Calcaneal stress fractures during the postoperative period following total knee or total hip arthroplasty may not be as rare as previously thought. Because clinical symptoms of the fracture appear insidiously and radiographic findings are absent or subtle in the early stage, a high index of suspicion is needed for orthopaedic surgeons to make the correct diagnosis. Magnetic resonance imaging or repeated radiographs may be necessary to make the correct diagnosis when no abnormality is apparent on the initial radiograph.

  17. Invariant hip moment pattern while walking with a robotic hip exoskeleton.

    PubMed

    Lewis, Cara L; Ferris, Daniel P

    2011-03-15

    Robotic lower limb exoskeletons hold significant potential for gait assistance and rehabilitation; however, we have a limited understanding of how people adapt to walking with robotic devices. The purpose of this study was to test the hypothesis that people reduce net muscle moments about their joints when robotic assistance is provided. This reduction in muscle moment results in a total joint moment (muscle plus exoskeleton) that is the same as the moment without the robotic assistance despite potential differences in joint angles. To test this hypothesis, eight healthy subjects trained with the robotic hip exoskeleton while walking on a force-measuring treadmill. The exoskeleton provided hip flexion assistance from approximately 33% to 53% of the gait cycle. We calculated the root mean squared difference (RMSD) between the average of data from the last 15 min of the powered condition and the unpowered condition. After completing three 30-min training sessions, the hip exoskeleton provided 27% of the total peak hip flexion moment during gait. Despite this substantial contribution from the exoskeleton, subjects walked with a total hip moment pattern (muscle plus exoskeleton) that was almost identical and more similar to the unpowered condition than the hip angle pattern (hip moment RMSD 0.027, angle RMSD 0.134, p<0.001). The angle and moment RMSD were not different for the knee and ankle joints. These findings support the concept that people adopt walking patterns with similar joint moment patterns despite differences in hip joint angles for a given walking speed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Minimally invasive hip arthroplasty: what role does patient preconditioning play?

    PubMed

    Pour, Aidin Eslam; Parvizi, Javad; Sharkey, Peter F; Hozack, William J; Rothman, Richard H

    2007-09-01

    The benefits of minimally invasive total hip arthroplasty continue to be debated. The objective of this study was to investigate the role of patient education, accelerated rehabilitation, and improved pain control on the outcome of total hip arthroplasty performed through a small incision. One hundred patients undergoing total hip arthroplasty at our institution were randomized into one of four groups on the basis of the size of the incision, preoperative counseling, the type of preoperative and postoperative rehabilitation, and the analgesia protocol. The operative parameters, complications, time to discharge to home, functional improvement, and patient satisfaction were assessed. The demographic distribution among the four groups was similar. The extent of functional improvement at the time of discharge to home, patient satisfaction, and walking ability at the time of discharge were better in patients who had received an accelerated preoperative and postoperative rehabilitation regimen regardless of the size of the incision. There was no difference in estimated blood loss, mean operative time, transfusion needs, or complications among the groups. This study highlights the importance of factors such as family education, patient preconditioning, preemptive analgesia, and accelerated preoperative and postoperative rehabilitation in influencing the outcome of total hip arthroplasty. The aforementioned factors, and not the surgical technique per se, may play a major role in imparting the better outcome after minimally invasive total hip arthroplasty that has been reported by various investigators.

  19. [Progress assessment of rehabilitation in patients after hip replacement. Preliminary report].

    PubMed

    Labecka, Monika; Pingot, Mariusz; Pingot, Julia; Woldańiska-Okońska, Marta

    2014-01-01

    Coxarthrosis is one of the most common diseases of the motor system. We distinguish primary and secondary coxarthrosis. The premises for total hip replacement include pain, damage to the surface of the acetabulum and the head of the hip, relative shortening of the limb, gluteal, femur and crus muscle atrophy and gait dysfunctions. The aim of this paper is to present the influence of rehabilitation on the improvement of physical ability, especially in respect to quality of gait and antianalgesic efficacy of the physical therapy in patients after total hip replacement. The study was carried out in 37 patients aged 35-72 (mean of age--53.78 +/- 9.92). The group consisted'of 21 women and 16 men. After the total hip replacement, all the patients underwent physical therapy which involved application of laser radiation on the postoperative scar, whirpool and classic massage of the operated limb, exercises in non-weight bearing and weight-bearing exercises and gait reeducation. Modified Laitinen Pain Indicator Questionnaire, Visual Analogue Scale-VAS and the standardized mobility test--Timed-Up-And-Go test were used in the study. The statistical analysis was carried out with the use of the STATYSTIKA 5 PL computer program. The results reached point to the analgesic efficacy of the physical therapy and a better gait quality. Multifactor physical therapy after total hip replacement shows analgesic action. Appropriate selection of exercises and physical treatment have positive influence on gait reeducation in patients after total hip replacement. The Timed Up and Go test may be used in functional assessment of gait in patients with musculoskeletal disorders.

  20. A new system of computer-assisted navigation leading to reduction in operating time in uncemented total hip replacement in a matched population.

    PubMed

    Chaudhry, Fouad A; Ismail, Sanaa Z; Davis, Edward T

    2018-05-01

    Computer-assisted navigation techniques are used to optimise component placement and alignment in total hip replacement. It has developed in the last 10 years but despite its advantages only 0.3% of all total hip replacements in England and Wales are done using computer navigation. One of the reasons for this is that computer-assisted technology increases operative time. A new method of pelvic registration has been developed without the need to register the anterior pelvic plane (BrainLab hip 6.0) which has shown to improve the accuracy of THR. The purpose of this study was to find out if the new method reduces the operating time. This was a retrospective analysis of comparing operating time in computer navigated primary uncemented total hip replacement using two methods of registration. Group 1 included 128 cases that were performed using BrainLab versions 2.1-5.1. This version relied on the acquisition of the anterior pelvic plane for registration. Group 2 included 128 cases that were performed using the newest navigation software, BrainLab hip 6.0 (registration possible with the patient in the lateral decubitus position). The operating time was 65.79 (40-98) minutes using the old method of registration and was 50.87 (33-74) minutes using the new method of registration. This difference was statistically significant. The body mass index (BMI) was comparable in both groups. The study supports the use of new method of registration in improving the operating time in computer navigated primary uncemented total hip replacements.

  1. Non-sedentary Lifestyle Can Reduce Hip Fracture Risk among Older Caucasians Adults: The Adventist Health Study-2.

    PubMed

    Lousuebsakul-Matthews, Vichuda; Thorpe, Donna; Knutsen, Raymond; Beeson, W Larry; Fraser, Gary E; Knutsen, Synnove F

    2015-01-01

    The beneficial effect of physical activity on reducing hip fracture risk has been supported in many previous studies. The present cohort study explores the relationship between total daily physical activity expressed as MET-hour/day and hip fracture risk among men over 50 years of age and postmenopausal women (n=22,836). Associations between self-reported hip fracture incidence and total daily physical activity and selected lifestyle factors were assessed using Cox proportional hazard regression. In gender-specific multivariable models, total activity above average (≥ 51 MET-hours per day for men, ≥ 48 MET-hours per day for women) compared to those with sedentary lifestyle (< 40 MET-hours per day) reduced the risk of hip fracture by 60% among men (HR=0.40, 95%CI: 0.23-0.70) (Ptrend=0.002) and 48% among women (HR=0.52, 95%CI: 0.32-0.84) (Ptrend=0.01). Our findings suggest that a moderate level of physical activity and avoiding a sedentary lifestyle can reduce the risk of hip fracture among the elderly.

  2. The effectiveness of inpatient physical therapy compared to outpatient physical therapy in older adults after total hip replacement in the post-discharge period: a systematic review.

    PubMed

    Klugarova, Jitka; Klugar, Miloslav; Mareckova, Jana; Gallo, Jiri; Kelnarova, Zuzana

    2016-01-01

    Total hip replacement is the most effective and safest method for treating severe degenerative, traumatic and other diseases of the hip joint. Total hip replacement can reliably relieve pain and improve function in the majority of patients for a period of 15 to 20 years or more postoperatively. Physical therapy follows each total hip replacement surgery. Physical therapy protocols after total hip replacement in the post-discharge period vary widely in terms of setting (inpatient, outpatient), content (the particular set of exercises used), and frequency (e.g. daily versus twice a week). In current literature, there is no systematic review which has compared the effectiveness of inpatient and outpatient physical therapy in patients after total hip replacement in the post-discharge period. The objective of this systematic review was to compare the effectiveness of inpatient physical therapy with outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. This review considered studies that include older adults (over 65 years) who have had total hip replacement and are in the post-discharge period. Adults with bilateral or multiple simultaneous surgeries and also patients who have had hemiarthroplasty of the hip joint were excluded.This review considered studies that included any type of physical therapy delivered in inpatient settings provided by professionals with education in physical therapy. Inpatient physical therapy delivered at any frequency and over any duration was included.This review considered studies that included as a comparator any type of physical therapy delivered in outpatient settings provided by professionals with education in physical therapy or no physical therapy.This review considered studies that included the following primary and secondary outcomes. The primary outcome was quality of life, assessed by any validated assessment tool. The secondary outcome was measures of gait assessed by any valid methods.This review considered both experimental and observational study designs including randomized controlled trials, non-randomized controlled trials, quasi-experimental, before and after studies, prospective and retrospective cohort studies, case control studies and analytical cross sectional studies for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in 12 databases. Studies published in all languages and any date were considered for inclusion in this review. Assessment of methodological quality was not conducted as no studies were identified that met the inclusion criteria. Data extraction and synthesis was not performed because no studies were included in this systematic review. During to the three-step search strategy 4330 papers were identified. The primary and secondary reviewer independently retrieved 42 potentially relevant papers according to the inclusion criteria by title and abstract screening. Following assessment of full text all of the retrieved papers were excluded based on the inclusion criteria. There is no scientific evidence comparing the effectiveness of inpatient physical therapy with outpatient physical therapy in older patients after total hip replacement in the post-discharge period. This systematic review has identified gaps in the literature for comparing the effectiveness of inpatient physical therapy with and outpatient physical therapy on the quality of life and gait measures in older adults after total hip replacement in the post-discharge period. Prospective randomized double blind multicenter controlled trials are needed to answer this important clinical question.

  3. A Multi-centre Study to Assess the Long-term Performance of the Summit™ Hip in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-08-03

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  4. The History of Biomechanics in Total Hip Arthroplasty.

    PubMed

    Houcke, Jan Van; Khanduja, Vikas; Pattyn, Christophe; Audenaert, Emmanuel

    2017-01-01

    Biomechanics of the hip joint describes how the complex combination of osseous, ligamentous, and muscular structures transfers the weight of the body from the axial skeleton into the appendicular skeleton of the lower limbs. Throughout history, several biomechanical studies based on theoretical mathematics, in vitro , in vivo as well as in silico models have been successfully performed. The insights gained from these studies have improved our understanding of the development of mechanical hip pathologies such as osteoarthritis, hip fractures, and developmental dysplasia of the hip. The main treatment of end-stage degeneration of the hip is total hip arthroplasty (THA). The increasing number of patients undergoing this surgical procedure, as well as their demand for more than just pain relief and leading an active lifestyle, has challenged surgeons and implant manufacturers to deliver higher function as well as longevity with the prosthesis. The science of biomechanics has played and will continue to play a crucial and integral role in achieving these goals. The aim of this article, therefore, is to present to the readers the key concepts in biomechanics of the hip and their application to THA.

  5. Total hip arthroplasty in dwarfism. A case report.

    PubMed

    De Fine, Marcello; Traina, Francesco; Palmonari, Massimo; Tassinari, Enrico; Toni, Aldo

    2008-05-01

    In dwarfism hip arthritis, usually secondary to hip dysplasia, is a common finding at an early age. In these patients a joint replacement is a demanding procedure due to the peculiar joint deformity and the small size of the bones. We present a case of a bilateral hip replacement in a dwarf patient. In order to reduce intraoperative complications and improve the joint kinematics a thorough preoperative planning was performed by a CT based computerised system. On the basis of the planning we chose a conical shaped stem that enable as to restore limb length and offset with a low risk of femoral fracture. In conclusion, we consider total hip replacement in dwarfism a safe and effective procedure if an accurate preoperative planning is performed.

  6. The epidemiology of bearing surface usage in total hip arthroplasty in the United States.

    PubMed

    Bozic, Kevin J; Kurtz, Steven; Lau, Edmund; Ong, Kevin; Chiu, Vanessa; Vail, Thomas P; Rubash, Harry E; Berry, Daniel J

    2009-07-01

    Hard-on-hard bearings offer the potential to improve the survivorship of total hip arthroplasty implants. However, the specific indications for the use of these advanced technologies remain controversial. The purpose of this study was to characterize the epidemiology of bearing surface utilization in total hip arthroplasty in the United States with respect to patient, hospital, geographic, and payer characteristics. The Nationwide Inpatient Sample database was used to analyze bearing type and demographic characteristics associated with 112,095 primary total hip arthroplasties performed in the United States between October 1, 2005, and December 31, 2006. The prevalence of each type of total hip arthroplasty bearing was calculated for population subgroups as a function of age, sex, census region, payer class, and hospital type. The most commonly reported bearing was metal-on-polyethylene (51%) followed by metal-on-metal (35%) and ceramic-on-ceramic (14%). Metal-on-polyethylene bearings were most commonly reported in female Medicare patients who were sixty-five to seventy-four years old, while metal-on-metal and ceramic-on-ceramic bearings were most commonly reported in privately insured male patients who were less than sixty-five years old. Thirty-three percent of patients over sixty-five years old had a hard-on-hard bearing reported. There was substantial regional variation in bearing usage; the highest prevalence of metal-on-polyethylene bearings was reported in the Northeast and at nonteaching hospitals, and the highest prevalence of metal-on-metal bearings was reported in the South and at teaching hospitals. The usage of total hip arthroplasty bearings varies considerably by patient characteristics, hospital type, and geographic location throughout the United States. Despite uncertain advantages in older patients, hard-on-hard bearings are commonly used in patients over the age of sixty-five years. Further study is necessary to define the appropriate indications for these advanced technologies in total hip arthroplasty.

  7. Complication Rates for Hip Arthroscopy Are Underestimated: A Population-Based Study.

    PubMed

    Truntzer, Jeremy N; Hoppe, Daniel J; Shapiro, Lauren M; Abrams, Geoffrey D; Safran, Marc

    2017-06-01

    To identify major and minor complication rates associated with hip arthroscopy from a payer-based national database and compare with the rates reported in the existing literature. Patients who underwent hip arthroscopy between 2007 and 2014 were identified using PearlDiver, a publicly available database. Rates of major and minor complications, as well as conversion to total hip arthroscopy (THA), were determined by using Current Procedural Terminology (CPT) and International Classification of Diseases, Ninth Revision (ICD-9), codes. Incidence rates of select major complications across the entire database were used as a comparison group. Statistical significance was set at P < .05. Of 18 million patients screened from 2007 to 2014, a total of 2,581 hip arthroscopies were identified. The rates of major and minor complications within a 1-year postoperative period were 1.74% and 4.22%, respectively. Complications included heterotopic ossification (2.85%), bursitis (1.23%), proximal femur fracture (1.08%), deep vein thrombosis (0.79%), and hip dislocation (0.58%). The rate of conversion to THA within 1 year was 2.85%. When compared to rates in the general population, the relative risks [RRs] of requiring a THA (age <50 years, RR = 57.66, P < .001; age >50 years, RR = 22.05, P < .001), sustaining a proximal femur fracture (age <50 years, RR = 18.02, P < .001; age >50 years, RR = 2.23, P < .001), or experiencing a hip dislocation (RR 19.60, P < .001) at 1 year after hip arthroscopy were significantly higher in all age groups. Higher major complication rates after hip arthroscopy were observed using a national payer-based database than previously reported in the literature, especially in regard to hip dislocations and proximal femur fractures. Rates of total hip arthroplasty were similar to prior studies, whereas the rates of revision hip arthroscopy were higher. Level IV, case series. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Treatment of primary hip osteoarthritis for the primary care physician and the indications for total hip arthroplasty.

    PubMed

    Levine, Mathew E; Nace, James; Kapadia, Bhaveen H; Issa, Kimona; Banerjee, Samik; Cherian, Jeffery J; Mont, Michael A

    2013-01-01

    Osteoarthritis is a degenerative condition that commonly affects knees and hips with an annual incidence of 88 in 100,000 people in the United States. The purpose of this study was to review the clinical presentation of osteoarthritis of the hip as well as the available management options. We reviewed the recent literature in regard to epidemiology, presentation, and treatment options available to patients. Nonoperative treatments include weight loss and low-impact, aerobic exercises. Along with weight loss and exercise, nonsteroidal anti-inflammatory drugs (NSAIDS), narcotics, and intra-articular steroid injections have been used to improve patient's symptoms. Surgical intervention is a viable option; however, indications such as severe pain that is refractory to nonsurgical management, osteophytes, or joint space narrowing on radiographic films, or impairment of function should be present. The most common surgical option, total hip arthroplasty, has been shown to improve a patient's physical and psychological well-being. However, inherent risks are present with surgery and these should be addressed with the patient so a sound decision can be made. Osteoarthritis of the hip can be bothersome to patients, but physicians can begin management with lifestyle changes or pharmaceuticals. In the event nonoperative measures fail to markedly improve quality of life, total hip arthroplasty remains a viable option.

  9. Aspirin or Rivaroxaban for VTE Prophylaxis after Hip or Knee Arthroplasty.

    PubMed

    Anderson, David R; Dunbar, Michael; Murnaghan, John; Kahn, Susan R; Gross, Peter; Forsythe, Michael; Pelet, Stephane; Fisher, William; Belzile, Etienne; Dolan, Sean; Crowther, Mark; Bohm, Eric; MacDonald, Steven J; Gofton, Wade; Kim, Paul; Zukor, David; Pleasance, Susan; Andreou, Pantelis; Doucette, Steve; Theriault, Chris; Abianui, Abongnwen; Carrier, Marc; Kovacs, Michael J; Rodger, Marc A; Coyle, Doug; Wells, Philip S; Vendittoli, Pascal-Andre

    2018-02-22

    Clinical trials and meta-analyses have suggested that aspirin may be effective for the prevention of venous thromboembolism (proximal deep-vein thrombosis or pulmonary embolism) after total hip or total knee arthroplasty, but comparisons with direct oral anticoagulants are lacking for prophylaxis beyond hospital discharge. We performed a multicenter, double-blind, randomized, controlled trial involving patients who were undergoing total hip or knee arthroplasty. All the patients received once-daily oral rivaroxaban (10 mg) until postoperative day 5 and then were randomly assigned to continue rivaroxaban or switch to aspirin (81 mg daily) for an additional 9 days after total knee arthroplasty or for 30 days after total hip arthroplasty. Patients were followed for 90 days for symptomatic venous thromboembolism (the primary effectiveness outcome) and bleeding complications, including major or clinically relevant nonmajor bleeding (the primary safety outcome). A total of 3424 patients (1804 undergoing total hip arthroplasty and 1620 undergoing total knee arthroplasty) were enrolled in the trial. Venous thromboembolism occurred in 11 of 1707 patients (0.64%) in the aspirin group and in 12 of 1717 patients (0.70%) in the rivaroxaban group (difference, 0.06 percentage points; 95% confidence interval [CI], -0.55 to 0.66; P<0.001 for noninferiority and P=0.84 for superiority). Major bleeding complications occurred in 8 patients (0.47%) in the aspirin group and in 5 (0.29%) in the rivaroxaban group (difference, 0.18 percentage points; 95% CI, -0.65 to 0.29; P=0.42). Clinically important bleeding occurred in 22 patients (1.29%) in the aspirin group and in 17 (0.99%) in the rivaroxaban group (difference, 0.30 percentage points; 95% CI, -1.07 to 0.47; P=0.43). Among patients who received 5 days of rivaroxaban prophylaxis after total hip or total knee arthroplasty, extended prophylaxis with aspirin was not significantly different from rivaroxaban in the prevention of symptomatic venous thromboembolism. (Funded by the Canadian Institutes of Health Research; ClinicalTrials.gov number, NCT01720108 .).

  10. Walking efficiency before and after total hip replacement.

    PubMed

    Brown, M; Hislop, H J; Waters, R L; Porell, D

    1980-10-01

    The energy cost of walking and gait characteristics of patients with hip disease were studied to determine changes in walking efficiency following total hip replacement. Twenty-nine patients, 24 with unilateral hip disease and 5 with bilateral hip disease, were tested preoperatively and at various times postoperatively. Oxygen uptake was measured by a modified Douglas bag procedure. The temporal and distance characteristics of gait were measured with contact closing heel switches. Results showed postoperative increases in velocity, cadence, and stride length in patients with unilateral disease and with bilateral disease with bilateral replacement. After surgery, energy cost tended toward more normal levels, but the subjects were not within normal limits for oxygen uptake per minute, oxygen uptake per distance walked, or percent of predicted maximum aerobic capacity. Comparison of energy expenditure data with temporal and distance factors of gait indicated that all subjects became more physiologically efficient after hip replacement.

  11. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys

    PubMed Central

    2010-01-01

    Background Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Methods Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. Results The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Conclusions Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting. PMID:20958990

  12. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    PubMed

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  13. Total hip arthroplasty and perioperative oral carbohydrate treatment: a randomised, double-blind, controlled trial.

    PubMed

    Harsten, Andreas; Hjartarson, Hjörtur; Toksvig-Larsen, Sören

    2012-06-01

    Perioperative oral carbohydrate intake is beneficial to general surgery patients. Total hip arthroplasty is a common surgical procedure, and even a moderate improvement in patient outcome could have a significant effect on the resources needed for these patients. However, few studies have focused on the effects of carbohydrate intake on orthopaedic patients. The purpose of this study was to investigate if perioperative oral carbohydrate intake alters the postoperative course for patients undergoing total hip arthroplasty. The primary hypothesis was that pain scores would be lower in patients treated with carbohydrate. A randomised, double-blind, controlled trial. This study was carried out between September 2009 and April 2011 at a district Swedish hospital that specialises in orthopaedic surgery. Sixty ASA physical status I-III patients scheduled for elective total hip arthroplasty were included. Exclusion criteria were obesity, diabetes, prior hip surgery to the same hip, ongoing infection, immunological deficiency or age less than 50 or more than 80 years. Patients were given 400 ml of either an oral 12.5% carbohydrate solution or a placebo beverage (flavoured water) 1.5 h before and 2 h after surgery. Visual analogue scales were used to score six discomfort parameters. Immediately prior to surgery, the carbohydrate-treated patients were less hungry (median score 9.5 vs. 22 mm) and experienced less nausea (0 vs. 1.5 mm) (P< 0.05). Postoperatively, patients in the carbohydrate group experienced less pain at 12, 16 and 20 h (median scores 20, 30 and 34 vs. 7, 5 and 0 mm; P<0.05). This study shows that there is limited benefit from administering oral carbohydrate prior to total hip arthroplasty.

  14. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    PubMed

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  15. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report

    PubMed Central

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je

    2015-01-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture. PMID:27536622

  16. The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study.

    PubMed

    Bayliss, Lee E; Culliford, David; Monk, A Paul; Glyn-Jones, Sion; Prieto-Alhambra, Daniel; Judge, Andrew; Cooper, Cyrus; Carr, Andrew J; Arden, Nigel K; Beard, David J; Price, Andrew J

    2017-04-08

    Total joint replacements for end-stage osteoarthritis of the hip and knee are cost-effective and demonstrate significant clinical improvement. However, robust population based lifetime-risk data for implant revision are not available to aid patient decision making, which is a particular problem in young patient groups deciding on best-timing for surgery. We did implant survival analysis on all patients within the Clinical Practice Research Datalink who had undergone total hip replacement or total knee replacement. These data were adjusted for all-cause mortality with data from the Office for National Statistics and used to generate lifetime risks of revision surgery based on increasing age at the time of primary surgery. We identified 63 158 patients who had undergone total hip replacement and 54 276 who had total knee replacement between Jan 1, 1991, and Aug 10, 2011, and followed up these patients to a maximum of 20 years. For total hip replacement, 10-year implant survival rate was 95·6% (95% CI 95·3-95·9) and 20-year rate was 85·0% (83·2-86·6). For total knee replacement, 10-year implant survival rate was 96·1% (95·8-96·4), and 20-year implant survival rate was 89·7% (87·5-91·5). The lifetime risk of requiring revision surgery in patients who had total hip replacement or total knee replacement over the age of 70 years was about 5% with no difference between sexes. For those who had surgery younger than 70 years, however, the lifetime risk of revision increased for younger patients, up to 35% (95% CI 30·9-39·1) for men in their early 50s, with large differences seen between male and female patients (15% lower for women in same age group). The median time to revision for patients who had surgery younger than age 60 was 4·4 years. Our study used novel methodology to investigate and offer new insight into the importance of young age and risk of revision after total hip or knee replacement. Our evidence challenges the increasing trend for more total hip replacements and total knee replacements to be done in the younger patient group, and these data should be offered to patients as part of the shared decision making process. Oxford Musculoskeletal Biomedical Research Unit, National Institute for Health Research. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  17. Editorial Commentary: Hip Arthroscopy Plays a Role in Painful Hip Resurfacing Arthroplasty but a Prearthroscopy Diagnosis Is Critical to Outcome.

    PubMed

    Rossi, Michael J

    2016-03-01

    Whereas hip arthroscopy plays a role in the investigation and treatment of the painful hip resurfacing arthroplasty, a diagnosis before arthroscopy is critical to improved outcome. The rate of conversion to total hip arthroplasty jumps from 7% to 37% when a pre-arthroscopy diagnosis is not known. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Protective Effect of High Protein and Calcium Intake on the Risk of Hip Fracture in the Framingham Offspring Cohort

    PubMed Central

    Sahni, Shivani; Cupples, L Adrienne; Mclean, Robert R; Tucker, Katherine L; Broe, Kerry E; Kiel, Douglas P; Hannan, Marian T

    2010-01-01

    The effect of protein on bone is controversial, and calcium intake may modify protein's effect on bone. We evaluated associations of energy-adjusted tertiles of protein intake (ie, total, animal, plant, animal/plant ratio) with incident hip fracture and whether total calcium intake modified these associations in the Framingham Offspring Study. A total of 1752 men and 1972 women completed a baseline food frequency questionnaire (1991–1995 or 1995–1998) and were followed for hip fracture until 2005. Hazard ratios (HRs) were estimated using Cox proportional hazards regression adjusting for confounders. Baseline mean age was 55 years (SD 9.9 years, range 26 to 86 years). Forty-four hip fractures occurred over 12 years of follow-up. Owing to significant interaction between protein (total, animal, animal/plant ratio) and calcium intake (p interaction range = .03 to .04), stratified results are presented. Among those with calcium intakes less than 800 mg/day, the highest tertile (T3) of animal protein intake had 2.8 times the risk of hip fracture [HR = 2.84, 95% confidence interval (CI) 1.20–6.74, p = .02] versus the lowest tertile (T1, p trend = .02). In the 800 mg/day or more group, T3 of animal protein had an 85% reduced hip fracture risk (HR = 0.15, 95% CI 0.02–0.92, p = .04) versus T1 (p trend = .04). Total protein intake and the animal/plant ratio were not significantly associated with hip fracture (p range = .12 to .65). Our results from middle-aged men and women show that higher animal protein intake coupled with calcium intake of 800 mg/day or more may protect against hip fracture, whereas the effect appears reversed for those with lower calcium intake. Calcium intake modifies the association of protein intake and the risk of hip fracture in this cohort and may explain the lack of concordance seen in previous studies. © 2010 American Society for Bone and Mineral Research. PMID:20662074

  19. /sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip prostheses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weiss, P.E.; Mall, J.C.; Hoffer, P.B.

    1979-12-01

    A retrospective study was performed to determine the accuracy of /sup 99m/Tc-methylene diphosphonate bone imaging in the evaluation of total hip arthroplasty for loosening and/or infection. Using focally increased activity at the tip of the femoral component or in the region of the acetabular component as a criterion, the examination was 77% specific and 100% sensitive for loosening and/or infection. A possible explanation for the increased uptake at the tip of the femoral component and the role of this examination in the management of a painful total hip prosthesis are discussed.

  20. Hemorrhagic iliopsoas bursitis complicating well-functioning ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Park, Kyung Soon; Diwanji, Sanket R; Kim, Hyung Keun; Song, Eun Kyoo; Yoon, Taek Rim

    2009-08-01

    Iliopsoas bursitis has been increasingly recognized as a complication of total hip arthroplasty and is usually associated with polyethylene wear. Here, the authors report a case of hemorrhagic iliopsoas bursitis complicating an otherwise well-functioning ceramic-on-ceramic arthroplasty performed by minimal invasive modified 2-incision technique. The bursitis in turn resulted in femoral nerve palsy and femoral vein compression. In this report, there was no evidence to support that the bursitis was due to an inflammatory response to ceramic wear particles or any other wear particles originating from the total hip arthroplasty.

  1. Expect the best, prepare for the worst: surgeon and patient expectation of the outcome of primary total hip and knee replacement.

    PubMed Central

    Moran, M.; Khan, A.; Sochart, D. H.; Andrew, G.

    2003-01-01

    A cross-sectional study of 100 surgeons and 370 patients awaiting primary total hip or knee replacement was carried out. Oxford hip or knee score questionnaires were sent to the surgeons and patients. They were asked to predict the level of symptoms expected 6 months following surgery. The Oxford scores derive a value of 12-60, with a greater score indicating worsening symptoms. The mean pre-operative score was 45.12 for the hip patients and 42.96 for the knee patients, and the patients expected this to drop to 23.70 and 25.66, respectively, 6 months' postoperatively. This was a significant difference for both groups. The surgeons expected the patients to have a mean postoperative score of 20.91 for the hip group and 22.19 for the knee group. The surgeons' scores were significantly lower than those from the patients. There was a significant difference between the patients' and surgeons' expectations of the results of total knee and hip replacement surgery. The surgeons expected better results than the patients. We believe that this is the first study that directly compares surgeon and patient expectations of lower limb arthroplasty. PMID:12831497

  2. Experimental pre-clinical assessment of the primary stability of two cementless femoral knee components.

    PubMed

    Berahmani, Sanaz; Hendriks, Maartje; Wolfson, David; Wright, Abraham; Janssen, Dennis; Verdonschot, Nico

    2017-11-01

    To achieve long-lasting fixation of cementless implants, an adequate primary stability is required. We aimed to compare primary stability of a new cementless femoral knee component (Attune®) against a conventional implant (LCS®) under different loading conditions. Six pairs of femora were prepared following the normal surgical procedure. Calibrated CT-scans and 3D-optical scans of the bones were obtained to measure bone mineral density (BMD) and cut accuracy, respectively. Micromotions were measured in nine regions of interest at the bone-implant interface using digital image correlation. The reconstructions were subjected to the implant-specific's peak tibiofemoral load of gait and a deep knee bend loading profiles. Afterwards, the implants were pushed-off at a flexion angle of 150°. Micromotions of Attune were significantly lower than LCS under both loading conditions (P ≤ 0.001). Cut accuracy did not affect micromotions, and BMD was only a significant factor affecting the micromotions under simplified gait loading. No significant difference was found in high-flex push-off force, but Attune required a significantly higher load to generate excessive micromotions during push-off. Parallel anterior and posterior bone cuts in the LCS versus the tapered bone cuts of the Attune may explain the difference between the two designs. Additionally, the rims at the borders of the LCS likely reduced the area of contact with the bone for the LCS, which may have affected the initial fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. A Randomised Multi-centre Study to Compare the Long-term Performance of the Future Hip to 3 Other Implants in Primary Total Hip Replacement

    ClinicalTrials.gov

    2016-10-06

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis; Perthes Disease

  4. Estimating prevalence of osteoporosis: examples from industrialized countries.

    PubMed

    Wade, S W; Strader, C; Fitzpatrick, L A; Anthony, M S; O'Malley, C D

    2014-01-01

    In nine industrialized countries in North America, Europe, Japan, and Australia, country-specific osteoporosis prevalence (estimated from published data) at the total hip or hip/spine ranged from 9 to 38 % for women and 1 to 8 % for men. In these countries, osteoporosis affects up to 49 million individuals. Standardized country-specific prevalence estimates are scarce, limiting our ability to anticipate the potential global impact of osteoporosis. This study estimated the prevalence of osteoporosis in several industrialized countries (USA, Canada, five European countries, Australia, and Japan) using the World Health Organization (WHO) bone mineral density (BMD)-based definition of osteoporosis: BMD T-score assessed by dual-energy x-ray absorptiometry ≤-2.5. Osteoporosis prevalence was estimated for males and females aged 50 years and above using total hip BMD and then either total hip or spine BMD. We compiled published location-specific data, using the National Health and Nutrition Examination Survey (NHANES) III age and BMD reference groups, and adjusted for differences in disease definitions across sources. Relevant NHANES III ratios (e.g., male to female osteoporosis at the total hip) were applied where data were missing for countries outside the USA. Data were extrapolated from geographically similar countries as needed. Population counts for 2010 were used to estimate the number of individuals with osteoporosis in each country. For females, osteoporosis prevalence ranged from 9 % (UK) to 15 % (France and Germany) based on total hip BMD and from 16 % (USA) to 38 % (Japan) when spine BMD data were included. For males, prevalence ranged from 1 % (UK) to 4 % (Japan) based on total hip BMD and from 3 % (Canada) to 8 % (France, Germany, Italy, and Spain) when spine BMD data were included. Up to 49 million individuals met the WHO osteoporosis criteria in a number of industrialized countries in North America, Europe, Japan, and Australia.

  5. Impact of the Holocaust on the Rehabilitation Outcome of Older Patients Sustaining a Hip Fracture.

    PubMed

    Mizrahi, Eliyahu H; Lubart, Emilia; Heymann, Anthony; Leibovitz, Arthur

    2017-04-01

    Holocaust survivors report a much higher prevalence of osteoporosis and fracture in the hip joint compared to those who were not Holocaust survivors. To evaluate whether being a Holocaust survivor could affect the functional outcome of hip fracture in patients 64 years of age and older undergoing rehabilitation. A retrospective cohort study compromising 140 consecutive hip fracture patients was conducted in a geriatric and rehabilitation department of a university-affiliated hospital. Being a Holocaust survivor was based on registry data. Functional outcome was assessed by the Functional Independence Measure (FIM)TM at admission and discharge from the rehabilitation ward. Data were analyzed by t-test, chi-square test, and linear regression analysis. Total and motor FIM scores at admission (P = 0.004 and P = 0.006, respectively) and total and motor FIM gain scores at discharge (P = 0.008 and P = 0.004 respectively) were significantly higher in non-Holocaust survivors compared with Holocaust survivors. A linear regression analysis showed that being a Holocaust survivor was predictive of lower total FIM scores at discharge (β = -0.17, P = 0.004). Hip fracture in Holocaust survivors showed lower total, motor FIM and gain scores at discharge compared to non-Holocaust survivor patients. These results suggest that being a Holocaust survivor could adversely affect the rehabilitation outcome following fracture of the hip and internal fixation.

  6. Endoscopic resection of acetabular screw tip to decompress sciatic nerve following total hip arthroplasty.

    PubMed

    Yoon, Sun-Jung; Park, Myung-Sik; Matsuda, Dean K; Choi, Yun Ho

    2018-06-04

    Sciatic nerve injuries following total hip arthroplasty are disabling complications. Although degrees of injury are variable from neuropraxia to neurotmesis, mechanical irritation of sciatic nerve might be occurred by protruding hardware. This case shows endoscopic decompression for protruded acetabular screw irritating sciatic nerve, the techniques described herein may permit broader arthroscopic/endoscopic applications for management of complications after reconstructive hip surgery. An 80-year-old man complained of severe pain and paresthesias following acetabular component revision surgery. Physical findings included right buttock pain with radiating pain to lower extremity. Radiographs and computed tomography imaging showed that the sharp end of protruded screw invaded greater sciatic foramen anterior to posterior and distal to proximal direction at sciatic notch level. A protruding tip of the acetabular screw at the sciatic notch was decompressed by use of techniques gained from experience performing endoscopic sciatic nerve decompression. The pre-operative pain and paresthesias resolved post-operatively after recovering from anesthesia. This case report describes the first documented endoscopic resection of the tip of the acetabular screw irritating sciatic nerve after total hip arthroplasty. If endoscopic resection of an offending acetabular screw can be performed in a safe and minimally invasive manner, one can envision a future expansion of the role of hip arthroscopic surgery in several complications management after total hip arthroplasty.

  7. Effects of health intervention program on cardiometabolic risk profiles from health evaluation center in Asian population: a longitudinal study and propensity analysis.

    PubMed

    Liu, Chuan-Chuan; Hung, Chung-Lieh; Shih, Shou-Chuan; Ko, Hung-Ju; Chang, Ray-E

    2015-08-20

    Health intervention program (HIP) based on diet and lifestyle modifications had been shown to improve cardiovascular risks. The effects of such program on a variety of cardiometabolic outcome measures conducted in a strict analysis remained relatively unexplored. A total of 2,660 participants (mean age: 43.3 ± 10 years, 63.6% male) underwent annual health survey from our health evaluation department. We implemented health intervention program (HIP) in which diet and lifestyle modifications including smoking cessation and advised physical activities were introduced. We further studied the effects of HIP on several cardiometabolic outcome measures including Framingham, metabolic scores and renal function in terms of Egfr with a mean follow-up period of 38.5 months. Propensity score (PS) matching (HIP vs non-HIP group) was used to avoid effects of case selection bias. Totally 1,004 (502 subjects for each group) left after PS matching protocol (both HIP and non-HIP group). The HIP group showed significant decline of waist circumference (-1.46 ± 0.61, p = 0.016), post-prandial glucose (-6.77 ± 2.06, p = 0.001), and total cholesterol level (-4.42 ± 2.15, p = 0.04), with borderline increase in eGFR (1.72 ± 0.94, p = 0.068) after an average of 1.91 ± 1.14 year follow up period. Exercise behavior significantly increased for those who received HIP when compared to the non-HIP group (44.6 vs 52.4 %, p = 0.014). PS matching and difference-in-difference (DID) analysis further confirmed the beneficial effects of ATP III reduction by HIP (-0.36 ± 0.06, p < 0.05). We demonstrated in our study that several cardiometabolic profiles can be substantially improved after health intervention introduction at the health evaluation center, supporting the beneficial evidence of such health intervention programs implementation based on primary prevention view points.

  8. [Results and experiences of conversion of hip arthrodesis ].

    PubMed

    Schuh, A; Zeiler, G; Werber, S

    2005-03-01

    With the predictably good outcome of total hip arthroplasty today (THA), hip arthrodesis currently has limited indications. Over the long term, however, most patients develop secondary degenerative arthritis in the spine, contralateral hip, and ipsilateral knee due to overloading. The deteriorating condition of these joints eventually causes the onset of pain, which often requires conversion of a fused hip to a THA. The results and experiences of conversions of a hip arthrodesis into a THA are reported. Between 1 January 1985 and 31 December 2001 conversion of a previously performed arthrodesis of the hip to THA was carried out in a total of 45 patients; 34 patients could be followed up after the conversion to THA after a mean of 77.5 months (min.: 24, max.: 208). The primary indications for the conversion were low back pain (n=21) and ipsilateral knee pain (n=13). The mean age at the time of THA was 75.3 years (min.: 32, max.: 74). The mean time interval between the arthrodesis and the conversion to THA was 30.4 years (min.: 5, max.: 66). Of 34 hips, 29 (85%) were either pain free or had minimal pain. Complications included one persisting sciatic nerve palsy, two superficial infections, two periprosthetic fractures, and two heterotopic ossifications IV degrees with one recurrence of ankylosis and one marked reduction of motion. Revision arthroplasty was performed in four hips. Postoperatively 7 patients showed no limping, 11 showed a slight limp, and 17 a pronounced limp. Recurrent dislocations occurred in one patient. We conclude that this operation can lead to satisfactory results even after a long duration of the arthrodesis. There is a high rate of complications after conversion of a hip arthrodesis to a total hip arthroplasty. These issues must be carefully considered and discussed with the patient before any conversion procedure.

  9. Hip Replacement - Multiple Languages

    MedlinePlus

    ... Hip Replacement - العربية (Arabic) Bilingual PDF Health Information Translations Chinese, Simplified (Mandarin dialect) (简体中文) Expand Section Total ... Chinese, Simplified (Mandarin dialect)) Bilingual PDF Health Information Translations Chinese, Traditional (Cantonese dialect) (繁體中文) Expand Section Total ...

  10. Preventative Therapeutics for Heterotopic Ossification

    DTIC Science & Technology

    2015-10-01

    in the general population undergoing invasive surgeries such as total hip arthroplasty . There is also a congenital form of it that can affect...insults and can also occur in patients undergoing invasive surgeries, including total hip arthroplasty (6). HO is very common in our wounded service

  11. A comparison between patient recall and concurrent measurement of preoperative quality of life outcome in total hip arthroplasty.

    PubMed

    Howell, Jonathan; Xu, Min; Duncan, Clive P; Masri, Bassam A; Garbuz, Donald S

    2008-09-01

    The objective is to evaluate the reliability of patients' recall of preoperative pain and function during the immediate postoperation period after total hip arthroplasty. A prospective cohort of 104 patients completed a survey about their quality of life before operation, and recalled preoperative status at 3 days, 6 weeks, and 12 weeks after operation. Quality of life was measured by the Western Ontario and McMaster University Osteoarthritis Index, the Oxford-12 hip score, and the 12-item Short-Form score. The intraclass correlation coefficient and Spearman correlation coefficient were used to compare preoperative quality of life scores to the scores recalled. The reliability of recall remained high up to 3 months postoperation. Patients are able to accurately recall their preoperative function for up to 3 months after total hip arthroplasty.

  12. Total hip replacement and surface replacement for the treatment of pain and disability resulting from end-stage arthritis of the hip (review of technology appraisal guidance 2 and 44): systematic review and economic evaluation.

    PubMed

    Clarke, Aileen; Pulikottil-Jacob, Ruth; Grove, Amy; Freeman, Karoline; Mistry, Hema; Tsertsvadze, Alexander; Connock, Martin; Court, Rachel; Kandala, Ngianga-Bakwin; Costa, Matthew; Suri, Gaurav; Metcalfe, David; Crowther, Michael; Morrow, Sarah; Johnson, Samantha; Sutcliffe, Paul

    2015-01-01

    Total hip replacement (THR) involves the replacement of a damaged hip joint with an artificial hip prosthesis. Resurfacing arthroplasty (RS) involves replacement of the joint surface of the femoral head with a metal surface covering. To undertake clinical effectiveness and cost-effectiveness analysis of different types of THR and RS for the treatment of pain and disability in people with end-stage arthritis of the hip, in particular to compare the clinical effectiveness and cost-effectiveness of (1) different types of primary THR and RS for people in whom both procedures are suitable and (2) different types of primary THR for people who are not suitable for hip RS. Electronic databases including MEDLINE, EMBASE, The Cochrane Library, Current Controlled Trials and UK Clinical Research Network (UKCRN) Portfolio Database were searched in December 2012, with searches limited to publications from 2008 and sample sizes of ≥ 100 participants. Reference lists and websites of manufacturers and professional organisations were also screened. Systematic reviews of the literature were undertaken to appraise the clinical effectiveness and cost-effectiveness of different types of THR and RS for people with end-stage arthritis of the hip. Included randomised controlled trials (RCTs) and systematic reviews were data extracted and risk of bias and methodological quality were independently assessed by two reviewers using the Cochrane Collaboration risk of bias tool and the Assessment of Multiple Systematic Reviews (AMSTAR) tool. A Markov multistate model was developed for the economic evaluation of the technologies. Sensitivity analyses stratified by sex and controlled for age were carried out to assess the robustness of the results. A total of 2469 records were screened of which 37 were included, representing 16 RCTs and eight systematic reviews. The mean post-THR Harris Hip Score measured at different follow-up times (from 6 months to 10 years) did not differ between THR groups, including between cross-linked polyethylene and traditional polyethylene cup liners (pooled mean difference 2.29, 95% confidence interval -0.88 to 5.45). Five systematic reviews reported evidence on different types of THR (cemented vs. cementless cup fixation and implant articulation materials) but these reviews were inconclusive. Eleven cost-effectiveness studies were included; four provided relevant cost and utility data for the model. Thirty registry studies were included, with no studies reporting better implant survival for RS than for all types of THR. For all analyses, mean costs for RS were higher than those for THR and mean quality-adjusted life-years (QALYs) were lower. The incremental cost-effectiveness ratio for RS was dominated by THR, that is, THR was cheaper and more effective than RS (for a lifetime horizon in the base-case analysis, the incremental cost of RS was £11,284 and the incremental QALYs were -0.0879). For all age and sex groups RS remained clearly dominated by THR. Cost-effectiveness acceptability curves showed that, for all patients, THR was almost 100% cost-effective at any willingness-to-pay level. There were age and sex differences in the populations with different types of THR and variations in revision rates (from 1.6% to 3.5% at 9 years). For the base-case analysis, for all age and sex groups and a lifetime horizon, mean costs for category E (cemented components with a polyethylene-on-ceramic articulation) were slightly lower and mean QALYs for category E were slightly higher than those for all other THR categories in both deterministic and probabilistic analyses. Hence, category E dominated the other four categories. Sensitivity analysis using an age- and sex-adjusted log-normal model demonstrated that, over a lifetime horizon and at a willingness-to-pay threshold of £20,000 per QALY, categories A and E were equally likely (50%) to be cost-effective. A large proportion of the included studies were inconclusive because of poor reporting, missing data, inconsistent results and/or great uncertainty in the treatment effect estimates. This warrants cautious interpretation of the findings. The evidence on complications was scarce, which may be because of the absence or rarity of these events or because of under-reporting. The poor reporting meant that it was not possible to explore contextual factors that might have influenced study results and also reduced the applicability of the findings to routine clinical practice in the UK. The scope of the review was limited to evidence published in English in 2008 or later, which could be interpreted as a weakness; however, systematic reviews would provide summary evidence for studies published before 2008. Compared with THR, revision rates for RS were higher, mean costs for RS were higher and mean QALYs gained were lower; RS was dominated by THR. Similar results were obtained in the deterministic and probabilistic analyses and for all age and sex groups THR was almost 100% cost-effective at any willingness-to-pay level. Revision rates for all types of THR were low. Category A THR (cemented components with a polyethylene-on-metal articulation) was more cost-effective for older age groups. However, across all age-sex groups combined, the mean cost for category E THR (cemented components with a polyethylene-on-ceramic articulation) was slightly lower and the mean QALYs gained were slightly higher. Category E therefore dominated the other four categories. Certain types of THR appeared to confer some benefit, including larger femoral head sizes, use of a cemented cup, use of a cross-linked polyethylene cup liner and a ceramic-on-ceramic as opposed to a metal-on-polyethylene articulation. Further RCTs with long-term follow-up are needed. This study is registered as PROSPERO CRD42013003924. The National Institute for Health Research Health Technology Assessment programme.

  13. High prevalence of noise following Delta ceramic-on-ceramic total hip arthroplasty.

    PubMed

    Salo, P P; Honkanen, P B; Ivanova, I; Reito, A; Pajamäki, J; Eskelinen, A

    2017-01-01

    We evaluated the short-term functional outcome and prevalence of bearing-specific generation of audible noise in 301 patients (336 hips) operated on with fourth generation (Delta) medium diameter head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). There were 191 female (63%) and 110 male patients (37%) with a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years (1.3 to 3.4). Patients completed three questionnaires: Oxford Hip Score (OHS), Research and Development 36-item health survey (RAND-36) and a noise-specific symptom questionnaire. Plain radiographs were also analysed. A total of three hips (0.9%) were revised. There were 52 patients (54 hips, 17%) who reported noise, and in 25 (48%) of them the noise was frequently heard. In the multiple regression analysis, the only independent risk factor for noise was a specific THA brand, with a threefold increased risk (95% confidence intervals 1.39 to 6.45, p = 0.005) of noise compared with the reference THA brand. Patients with noisy hips had lower median OHS (43 versus 46.5, p = 0.002) and their physical functioning (p = 0.021) subscale in RAND-36 was reduced. Noise was surprisingly common in this population. Cite this article: Bone Joint J 2017;99-B:44-50. ©2017 The British Editorial Society of Bone & Joint Surgery.

  14. Comparison of Blood Loss After Total Hip Arthroplasty Between Ankylosing Spondylitis and Osteoarthritis.

    PubMed

    Li, Jia; Zhao, Jinzhu; He, Chongru; Tong, Wenwen; Zou, Yuming; Xu, Weidong

    2016-07-01

    This study was conducted to compare the blood loss during primary total hip arthroplasty (THA) between ankylosing spondylitis (AS) and hip osteoarthritis (OA). We reviewed 120 THAs in 68 patients comprising 3 groups: AS with total bony ankylosis of the hips (ASB), AS with stiff hips (ASS), and OA. Demographics, perioperative laboratory values, intraoperative data, blood loss, transfusion rate, transfusion reactions, surgical complications, hospitalization cost, and length of stay (LOS) were collected and analyzed among ASB, ASS, and OA groups. The patients of the ASB and ASS groups were much younger and thinner than those of the OA group. There were no significant differences in the preoperative values of activated partial thromboplastin time, prothrombin time, and international normalized ratio among the 3 groups (all P > .05). The intraoperative blood loss, volume of drainage, hidden blood loss, transfusion rate, transfusion reactions, and hospitalization cost in the ASB group were significantly higher than in the other 2 groups, although not significantly different between the ASS and OA groups (P > .05). Both AS and OA can cause hyperosteogeny to the hips, but ASB patients have more serious symptoms in their affected hips. This may cause more blood loss in THA surgery because of bone surface bleeding. The reason that ASB patients suffered more blood loss may be related to the high difficulty and long duration of the operation. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Extensive Surgical Wound Lavage Reduces the Incidence and Severity of Heterotopic Ossification in Primary Total Hip Replacement: A Study of 175 Hip Replacements.

    PubMed

    Kantak, Avadhoot P; Shah, Nirav N

    2017-12-01

    One of the local factors contributing to the formation of heterotopic ossification includes bone debris generated during the surgery. This risk can be partially nullified by use of saline wash. Our research aim was to ascertain if extensive intraoperative lavage can reduce the incidence and severity of heterotopic ossification in primary total hip arthroplasty. A retrospective case control radiological study of 145 patients (175 hip replacements). The control group received minimal intra-operative lavage (<1,000 mL); consisted of 90 primary hip replacements. The index group received extensive saline lavage (>3,000 mL), and included 85 primary hip replacements. Brooker classification was used to grade radiographs at one year for development of heterotopic ossification. Sixty-six patients in control group had heterotopic ossification, with six showing a significant grade (grade 3 or 4). Thirty-five patients in the index group had heterotopic ossification with no incidence of severe grade. Majority patients in the index group showed a predominantly grade 1 heterotopic ossification; 28 out of 35, as compared to 37 out of 66 in control group. There was a statistically significant difference in the incidence ( P <0.05) as well as severity of heterotopic ossification between the groups ( P <0.05). We conclude that use of extensive lavage during total hip replacement reduces the incidence as well as severity of heterotopic ossification.

  16. MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip.

    PubMed

    Nori, Madhavi; Marupaka, Sravan Kumar; Alluri, Swathi; Md, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran

    2015-12-01

    Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. To study pre and post core decompression MRI changes in avascular necrosis of hip. This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip.

  17. Impact of Tranexamic Acid in Total Knee and Total Hip Replacement.

    PubMed

    Boyle, Jaclyn A; Soric, Mate M

    2017-02-01

    To evaluate the net clinical benefit of tranexamic acid use in patients undergoing total knee or total hip replacement. This is a retrospective study of patients undergoing total knee or total hip replacement. The primary outcome was the net clinical benefit of tranexamic acid use. Secondary outcomes included length of stay, incidence of venous thromboembolism, change in hemoglobin, and number of units of blood transfused. Four hundred and six patients were screened for inclusion and 327 patients met inclusion criteria; 174 patients received tranexamic acid versus 153 patients who received usual care. Tranexamic acid demonstrated a positive net clinical benefit versus usual care (40.8% vs 13.7%, P < .01) but did not affect length of stay (3.39 vs 3.37 days, respectively, P = .76). Venous thromboembolism was comparable between groups (2.3% vs 0.7%, P = .38). Average change in hemoglobin and need for transfusion were lower in the treatment group versus the usual care group, respectively (3.46 vs 4.26 mg/dL, P < .01). Tranexamic acid demonstrated a significant benefit in decreasing change in hemoglobin as well as the need for blood transfusion with no increase in the risk of venous thromboembolism in patients undergoing total knee or total hip replacement.

  18. One step HIP canning of powder metallurgy composites

    NASA Technical Reports Server (NTRS)

    Juhas, John J. (Inventor)

    1990-01-01

    A single step is relied on in the canning process for hot isostatic pressing (HIP) powder metallurgy composites. The binders are totally removed while the HIP can of compatible refractory metal is sealed at high vacuum and temperature. This eliminates outgassing during hot isostatic pressing.

  19. [Gluteal compartment syndrome after total hip replacement. A presentation of two cases].

    PubMed

    Villalba, J; Solernou, X

    2013-01-01

    Many postoperative complications have been described after a total hip arthroplasty, with early and acute, as well as late, complications being reported. Two cases of compartment syndrome of the buttock are described following a hybrid total hip arthroplasty (cemented stem and press-fit and screwed acetabulum) performed on 2 patients of 60 and 68 years old, both diagnosed and treated 24-48 hours after the surgery. Both cases had a primary prosthesis with no previous significant pathological findings. This condition is still rare, and few cases have been described at the medical literature. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  20. Modes of failure of Osteonics constrained tripolar implants: a retrospective analysis of forty-three failed implants.

    PubMed

    Guyen, Olivier; Lewallen, David G; Cabanela, Miguel E

    2008-07-01

    The Osteonics constrained tripolar implant has been one of the most commonly used options to manage recurrent instability after total hip arthroplasty. Mechanical failures were expected and have been reported. The purpose of this retrospective review was to identify the observed modes of failure of this device. Forty-three failed Osteonics constrained tripolar implants were revised at our institution between September 1997 and April 2005. All revisions related to the constrained acetabular component only were considered as failures. All of the devices had been inserted for recurrent or intraoperative instability during revision procedures. Seven different methods of implantation were used. Operative reports and radiographs were reviewed to identify the modes of failure. The average time to failure of the forty-three implants was 28.4 months. A total of five modes of failure were observed: failure at the bone-implant interface (type I), which occurred in eleven hips; failure at the mechanisms holding the constrained liner to the metal shell (type II), in six hips; failure of the retaining mechanism of the bipolar component (type III), in ten hips; dislocation of the prosthetic head at the inner bearing of the bipolar component (type IV), in three hips; and infection (type V), in twelve hips. The mode of failure remained unknown in one hip that had been revised at another institution. The Osteonics constrained tripolar total hip arthroplasty implant is a complex device involving many parts. We showed that failure of this device can occur at most of its interfaces. It would therefore appear logical to limit its application to salvage situations.

  1. Investigation into three dimensional hip anatomy in anterior dislocation after THA. Influence of the position of the hip rotation centre.

    PubMed

    Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick

    2012-07-01

    The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. A case report of idiopathic iliopsoas hematoma which occurred soon after transfer to the wheelchair after total hip arthroplasty.

    PubMed

    Okumura, Tomoo; Fujita, Hiroshi; Harada, Hideto; Nishimura, Ryuuichi; Tominaga, Tomohiro

    2017-02-01

    A 79-year-old woman was diagnosed with osteoarthritis of the left hip and scheduled for total hip arthroplasty. As two lesions were detected in branches of the coronary arteries, she was treated with catheter treatment. The patient was receiving anticoagulant treatment, which was suspended eight days before the operation; however, heparin was started at 6 days before the operation and was stopped 9 hours before the operation. On the 2nd postoperative day soon after transfer to the wheel chair, she was feeling unwell and was suffering from severe pain in her left buttock and left thigh. Her blood pressure had decreased to 70 mmHg. During abdominal contrast-enhanced CT, a hematoma was detected in the left iliopsoas muscle. Catheter therapy was started by the cardiovascular department and bleeding had stopped spontaneously. The patient was able to walk with a cane and was discharged on the 40th postoperative day. THA: total hip arthroplasty, CT: computed tomography, JOA score: Japanese Orthopaedic Association hip score, HA: hydroxyapatite, PMMA: polymethyl-methacrylate, APTT: activated partial thromboplastin time.

  3. Patient-oriented Functional Results of Total Femoral Endoprosthetic Reconstruction Following Oncologic Resection

    PubMed Central

    Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.

    2011-01-01

    Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701

  4. Emerging technologies in arthroplasty: additive manufacturing.

    PubMed

    Banerjee, Samik; Kulesha, Gene; Kester, Mark; Mont, Michael A

    2014-06-01

    Additive manufacturing is an industrial technology whereby three-dimensional visual computer models are fabricated into physical components by selectively curing, depositing, or consolidating various materials in consecutive layers. Although initially developed for production of simulated models, the technology has undergone vast improvements and is currently increasingly being used for the production of end-use components in various aerospace, automotive, and biomedical specialties. The ability of this technology to be used for the manufacture of solid-mesh-foam monolithic and coated components of complex geometries previously considered unmanufacturable has attracted the attention of implant manufacturers, bioengineers, and orthopedic surgeons. Currently, there is a paucity of reports describing this fabrication method in the orthopedic literature. Therefore, we aimed to briefly describe this technology, some of the applications in other orthopedic subspecialties, its present use in hip and knee arthroplasty, and concerns with the present form of the technology. As there are few reports of clinical trials presently available, the true benefits of this technology can only be realized when studies evaluating the clinical and radiographic outcomes of cementless implants manufactured with additive manufacturing report durable fixation, less stress shielding, and better implant survivorship. Nevertheless, the authors believe that this technology holds great promise and may potentially change the conventional methods of casting, machining, and tooling for implant manufacturing in the future. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays.

    PubMed

    Murr, L E; Gaytan, S M; Medina, F; Lopez, H; Martinez, E; Machado, B I; Hernandez, D H; Martinez, L; Lopez, M I; Wicker, R B; Bracke, J

    2010-04-28

    In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the alpha-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.

  6. [The primary stability between manual and robot assisted implantation of hip prostheses: A biomechanical study on synthetic femurs].

    PubMed

    Decking, J; Gerber, A; Kränzlein, J; Meurer, A; Böhm, B; Plitz, W

    2004-01-01

    We investigated the initial stability of cementless stems implanted with robotic milling and conventional manual broaching. Proximally porous structured stems (G2, ESKA-Implants, Luebeck, Germany) were implanted into synthetic femora. In one group, the femoral cavity was prepared by a CT-based robot (CASPAR, URS-Ortho, Germany) with a high-speed milling head. In the other group, femora were rasped manually with broaches. The broaches had 1 mm proximal press-fit, the robotic cavities 1.5 mm. The implants were exposed to 15 000 loading cycles with 1 000 +/- 500 N. The direction of forces on the implant head were chosen to simulate stair climbing. Internal rotation and translation (caudal, dorsal and lateral) of the implants were measured by linear transducers. The robotic group showed significantly less reversible motion regarding translation in caudal, dorsal and lateral directions. The standard deviations of implant motions were smaller in the robotic group. Using robotic preparation of the femur, initial stability was higher and more consistent than with manual broaching, but differences in undersizing of the cavities created in the femur in relation to the implant may have contributed to these differences for the most part. In-vitro-loading experiments focusing on femoral cavities with varying press-fits are recommended before the introduction of new implants or operating procedures.

  7. The tribology of metal-on-metal total hip replacements.

    PubMed

    Scholes, S C; Unsworth, A

    2006-02-01

    Total hip surgery is an effective way of alleviating the pain and discomfort caused by diseased or damaged joints. However, in the majority of cases, these joints have a finite life. The main reason for failure is osteolysis (bone resorption). It is well documented that an important cause of osteolysis, and therefore the subsequent loosening and failure of conventional metal- or ceramic-on-ultra-high molecular weight polyethylene joints, is the body's immunological response to the polyethylene wear particles. To avoid this, interest has been renewed in metal-on-metal joints. The intention of this paper is to review the studies that have taken place within different laboratories to determine the tribological performance of new-generation metal-on-metal total hip replacements. These types of joint offer a potential solution to enhance the longevity of prosthetic hip systems; however, problems may arise owing to the effects of metal ion release, which are, as yet, not fully understood.

  8. Fibroblast growth factor 23, bone mineral density, and risk of hip fracture among older adults: the cardiovascular health study.

    PubMed

    Jovanovich, Anna; Bùzková, Petra; Chonchol, Michel; Robbins, John; Fink, Howard A; de Boer, Ian H; Kestenbaum, Bryan; Katz, Ronit; Carbone, Laura; Lee, Jennifer; Laughlin, Gail A; Mukamal, Kenneth J; Fried, Linda F; Shlipak, Michael G; Ix, Joachim H

    2013-08-01

    Fibroblast growth factor 23 (FGF23) is a phosphaturic hormone that also inhibits calcitriol synthesis. Our objective was to evaluate the relationships of plasma FGF23 concentrations with bone mineral density (BMD) and hip fracture in community-dwelling older adults. Linear regression and Cox proportional hazard models were used to examine the associations of plasma FGF23 concentrations with BMD and incident hip fracture, respectively. Analyses were also stratified by chronic kidney disease. Participants included 2008 women and 1329 men ≥65 years from the 1996 to 1997 Cardiovascular Health Study visit. Dual x-ray absorptiometry measured total hip (TH) and lumbar spine (LS) BMD in 1291 participants. Hip fracture incidence was assessed prospectively through June 30, 2008 by hospitalization records in all participants. Women had higher plasma FGF23 concentrations than men (75 [56-107] vs 66 [interquartile range = 52-92] relative units/mL; P < .001). After adjustment, higher FGF23 concentrations were associated with greater total hip and lumbar spine BMD in men only (β per doubling of FGF23 = 0.02, with 95% confidence interval [CI] = 0.001-0.04 g/cm(2), and 0.03 with 95% CI = 0.01-0.06 g/cm(2)). During 9.6 ± 5.1-11.0 years of follow-up, 328 hip fractures occurred. Higher FGF23 concentrations were not associated with hip fracture risk in women or men (adjusted hazard ratio = 0.95, with 95% CI = 0.78-1.15, and 1.09 with 95% CI = 0.82-1.46 per doubling of FGF23). Results did not differ by chronic kidney disease status (P > .4 for interactions). In this large prospective cohort of community-dwelling older adults, higher FGF23 concentrations were weakly associated with greater lumbar spine and total hip BMD but not with hip fracture risk.

  9. Is lower hip range of motion a risk factor for groin pain in athletes? A systematic review with clinical applications

    PubMed Central

    Tak, Igor; Engelaar, Leonie; Gouttebarge, Vincent; Barendrecht, Maarten; Van den Heuvel, Sylvia; Kerkhoffs, Gino; Langhout, Rob; Stubbe, Janine; Weir, Adam

    2017-01-01

    Background Whether hip range of motion (ROM) is a risk factor for groin pain in athletes is not known. Objectives To systematically review the relationship between hip ROM and groin pain in athletes in cross-sectional/case–control and prospective studies. Study design Systematic review, prospectively registered (PROSPERO) according to PRISMA guidelines. Methods Pubmed, Embase, CINAHL and SPORTDiscus were systematically searched up to December 2015. Two authors performed study selection, data extraction/analysis, quality assessment (Critical Appraisal Skills Programme) and strength of evidence synthesis. Results We identified seven prospective and four case–control studies. The total quality score ranged from 29% to 92%. Heterogeneity in groin pain classification, injury definitions and physical assessment precluded data pooling. There was strong evidence that total rotation of both hips below 85° measured at the pre-season screening was a risk factor for groin pain development. Strong evidence suggested that internal rotation, abduction and extension were not associated with the risk or presence of groin pain. Conclusion Total hip ROM is the factor most consistently related to groin pain in athletes. Screening for hip ROM is unlikely to correctly identify an athlete at risk of developing groin pain because of the small ROM differences found and poor ROM measurement properties. PMID:28432076

  10. [Optimizing primary total hip replacement--a technique to effect saving of manpower].

    PubMed

    Huber, J F; Rink, M; Broger, I; Zumstein, M; Ruflin, G B

    2003-01-01

    Development of a standardized surgical technique for total hip replacement thereby saving manpower (one assistant) by using a retractor system. Total hip replacement is performed with the patient in a true lateral position on a tunnel cushion. By means of a direct lateral approach the pelvitrochanteric muscles are partially detached using an omega-shaped cut. The Bookwalter retractor is fixed dorsally on the operating table. The ring is centered keeping the greater trochanter in the middle. The Hohmann retractors are fixed to the ring to sufficiently expose the acetabulum. To insert the femoral stem the ring needs to be opened dorsally and the patient's leg is bent 90 degrees in the hip and the knee over the tunnel cushion. The muscles inserting at the greater trochanter are retracted by a separate Hohmann retractor with weight. In a case control study with matched pairs the patients treated with this technique were compared with those treated in supine position with the transgluteal approach. The number of assistants required and the operating time were assessed. All the hip replacements with the patient in side position were performed with one assistant, in supine position with two assistants. The operating time did not differ significantly (supine position 110 min/side position 112 min). The complication rate in both groups was comparable (one secondary wound healing, one transient ischalgia). The process of total hip replacement can be optimized. The described technique allows to spare one surgical assistant without prolonging the operating time.

  11. Delivery of Antibiotics from Cementless Titanium-Alloy Cubes May Be a Novel Way to Control Postoperative Infections

    PubMed Central

    Bezuidenhout, Martin B.; van Staden, Anton D.; Oosthuizen, Gert A.; Dimitrov, Dimitar M.; Dicks, Leon M. T.

    2015-01-01

    Bacterial colonisation and biofilm formation onto orthopaedic devices are difficult to eradicate. In most cases infection is treated by surgical removal of the implant and cleaning of the infected area, followed by extensive treatment with broad-spectrum antibiotics. Such treatment causes great discomfort, is expensive, and is not always successful. In this study we report on the release of vancomycin through polyethersulfone membranes from channels in cementless titanium-alloy cubes. The cubes were constructed with LaserCUSING from Ti6Al4V ELI powder. Vancomycin was released by non-Fickian anomalous (constraint) diffusion. Approximately 50% of the vancomycin was released within the first 17 h. However, sustained delivery of vancomycin for 100 h was possible by reinjecting the channels. Refillable implants may be a novel way to control postoperative infections. PMID:25861649

  12. [EFFECTIVENESS OF BILATERAL TOTAL HIP AND KNEE ARTHROPLASTY FOR SEVERE INFLAMMATORY ARTHROPATHIES].

    PubMed

    Li, Xin; Li, Heng; Ni, Ming; Li, Xiang; Song, Xinggui; Kong, Xiangpeng; Li, Yucong; Chen, Jiying

    2016-11-08

    To evaluate the application and effectiveness of bilateral total hip arthroplasty and total knee arthroplasty in the treatment of severe inflammatory arthropathies. Between September 2008 and September 2015, 31 patients with severe inflammatory arthropathies were treated with bilateral total hip arthroplasty and total knee arthroplasty. Of 31 cases, 22 were male and 9 were female with an average age of 30 years (range, 20 to 41 years); there were 15 cases of rheumatoid arthritis and 16 cases of ankylosing spondylitis with an average onset age of 14 years (range, 5-28 years); all 4 ankylosed joints were observed in 11 cases, 3 ankylosed joints in 2 cases, 2 ankylosed joints in 6 cases, 1 ankylosed joint in 1 case, and no ankylosed joint in 11 cases. Before operation, the hip range of motion (ROM) value was (17.82±28.18)°, and the knee ROM value score was (26.45±30.18)°; the hip Harris score was 29.64±11.58, and the hospital for special surgery (HSS) score was 27.07±11.04. The patients were grouped and compared in accordance with etiology and ankylosed joint. One-stage arthroplasty was performed in 1 case, two-stage arthroplasty in 22 cases, three-stage arthroplasty in 7 cases, and four-stage arthroplasty in 1 case. The total operation time was 325-776 minutes; the total blood loss was 900-3 900 mL; the total transfusion volume was 2 220-8 070 mL; and the total hospitalization time was 21-65 days. The patients were followed up 12-94 months (mean, 51 months). The hip and knee ROM values, Harris score and HSS score at last follow-up were significantly improved when compared with preoperative ones ( P <0.05). The subjective satisfaction degree was good in 16 cases, moderate in 10 cases, and poor in 5 cases. Periprosthetic infection occurred in 2 cases (3 knees), joint stiffness in 3 cases (6 knees), joint instability in 1 case (1 knee), leg length discrepancy of >2 cm in 2 cases, and flexion deformity of 10° in 1 case (1 knee). The hip and knee ROM values, Harris score and HSS score showed no significant difference between patients with ankylosing spondylitis and patients rheumatoid arthritis at last follow-up ( P >0.05). The hip and knee ROM values of the patients with ankylosed joint were significantly lower than those of patients with no ankylosed joint ( P <0.05); the Harris score and HSS score of the patients with ankylosed joint were lower than those of patients with no ankylosed joint, but no significant difference was found ( P >0.05). A combination of bilateral hip and knee arthroplasty is an efficient treatment for severe lower extremities deformity, arthralgia and poor quality of life caused by inflammatory arthropathies. However, the postoperative periprosthetic infection and stiffness of knee are important complications influencing the effectiveness of operation.

  13. The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients

    PubMed Central

    2010-01-01

    Objective To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA. Design Retrospective clinical series Methods Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis. Results Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA. Conclusions In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures. PMID:20670440

  14. Trends in the phenotypic hip status of selected breeds of dog as measured by the New Zealand Veterinary Association Hip Dysplasia scheme (1990-2008).

    PubMed

    Worth, A J; Bridges, J P; Jones, G

    2011-03-01

    To determine whether there has been improvement in the phenotypic hip dysplasia status in four susceptible dog breeds as measured by the New Zealand Veterinary Association (NZVA) Canine Hip Dysplasia (CHD) scheme. A retrospective analysis of the NZVA CHD database was performed using records of all German Shepherd dogs, Labrador Retrievers, Golden Retrievers and Rottweilers that had undergone evaluation for hip dysplasia between 1990 and 2008. The effect of date of birth on the total hip score was analysed using linear regression, including the covariates of age and gender. When a significant effect of date of birth on total score was noted, ordinal logistic regression was performed to determine the probability of different grades of the Norberg angle and subluxation scores by year of birth; these categories being most indicative of laxity of the coxofemoral joint. Given the known heritability of hip phenotype, determined using radiological measurements, the hypothesis was that if sufficient selection pressure has been applied there would have been a trend towards a lower total score over time. For Labrador Retrievers (n=1,451), Golden Retrievers (n=896) and Rottweilers (n=313), there was no effect of date of birth on total score over the period of the study (p>0.1). For German Shepherd dogs (n=1,087), there was a significant trend to a lower total score over time (p=0.0003). However the actual size of the effect was small. Ordinal logistic regression on the Norberg angle and subluxation scores for German Shepherd dogs demonstrated a significant lowering of grade in both of these measures of hip laxity. This study failed to show significant improvement in the phenotypic hip status of three out of the four most populous large-dog breeds in the NZVA CHD database. Even in the German Shepherd dog, the trend towards a lower total score did not represent a substantial change. Lack of evidence of phenotypic improvement may be due to insufficient selection pressure over the course of the study, selective usage of the scheme (and thus a biased sample), or deficiencies within the NZVA CHD scoring method itself. Greater improvement might be possible if use of the scheme (or an equivalent) is made a compulsory requirement for registration of pedigree breeding stock, if greater selection pressure is applied and/or if pedigree data are included to enable estimations of breeding value.

  15. Does haptic robot-assisted total hip arthroplasty better restore native acetabular and femoral anatomy?

    PubMed

    Tsai, Tsung-Yuan; Dimitriou, Dimitris; Li, Jing-Sheng; Kwon, Young-Min

    2016-06-01

    The objective was to evaluate whether total hip arthroplasty (THA) using haptic robot assistance restores hip geometry better than the free-hand technique. Twelve robot-assisted and 14 free-hand unilateral THA patients underwent CT scan for three-dimensional (3D) hip models. The anteversion, inclination and hip joint centre locations of the native and implanted hips in each patient were quantified and compared. Significant increase of combined anteversion by 19.1 ± 11.7° and 23.5 ± 23.6° and decrease of cup inclination by 16.5 ± 6.0° and 10.2 ± 6.8° were observed in the robot-assisted and the free-hand THAs, respectively. Less variation in the difference of the component orientations (max 11.1 vs 18.3°) and the femoral head centre (max 4.5 vs 6.3 mm) were found in the robot-assisted group. This study demonstrated that neither robot-assisted nor free-hand THAs had fully restored native hip geometry. However, the higher precision of the robot-assisted THA suggested that it has potential utility in restoring the native hip geometry. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers.

    PubMed

    Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio

    2007-08-01

    Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.

  17. Lunar phase does not influence perioperative complications in total hip arthroplasty.

    PubMed

    Ficklscherer, Andreas; Angermann, Alexander; Weber, Patrick; Wegener, Bernd; Pietschmann, Matthias; Müller, Peter

    2012-02-29

    Lunar calendars, publishing recommendations for daily life, are gaining more and more attention in Germany, where 10.5% of the population believe in lunar effects on disease. A widespread and often heard belief is that a full moon has the most negative effects on surgical outcome. The present study evaluates the effects of lunar phase on perioperative complications in total hip arthroplasty. We performed a retrospective study with 305 patients being provided with a primary hip arthroplasty. To identify possible influences of the lunar phase on perioperative complications we investigated data such as operation length, blood loss and course of C-reactive protein that were collected during the patients' stay in the hospital and allocated them to moon illumination. There were no significant differences in all collected data concerning the lunar phase (p > 0.05). Although not statistically significant, there were fewer operations during the full moon phase. Therefore there is no evidence that lunar phase has an effect on perioperative complications in total hip arthroplasty. Fewer, though not significantly fewer, operations were performed during the full moon phase. Although this was not a prospective randomized trial, the statistical magnitude of the results does not support any recommendations for scheduling patients for total hip arthroplasty at any particular day of the lunar phase.

  18. The Role of Hip Arthroscopy in Investigating and Managing the Painful Hip Resurfacing Arthroplasty.

    PubMed

    Mei-Dan, Omer; Pascual-Garrido, Cecilia; Moreira, Brett; McConkey, Mark O; Young, David A

    2016-03-01

    To determine the safety and efficacy of hip arthroscopy performed in the peripheral compartment as a diagnostic and therapeutic treatment option for patients with hip pain after hip resurfacing surgery. Indications for hip arthroscopy after hip resurfacing included patients with a symptomatic hip-resurfaced arthroplasties who did not respond to nonoperative treatment. Patients who underwent a hip arthroscopy after a painful hip resurfacing were included with a minimum of 1 year follow-up. Subgroup analysis was performed according to whether an established diagnosis was made before arthroscopic intervention or not. Subjective measures were based on Western Ontario and McMaster Universities Arthritis Index (WOMAC) scores, and results were calculated and analyzed. We included 68 patients (26 male [38%] and 42 female [62%]) who underwent subsequent hip arthroscopy from a population of 978 consecutive hip-resurfaced arthroplasties performed between 1999 and 2010. The average age was 58 (range, 37 to 78 years). The mean follow-up after hip arthroscopy was 3.4 years (range, 12 months to 5.8 years). Patients who had an established diagnosis (n = 41) before hip arthroscopy showed statistical improvement in their WOMAC scores (7 to 2, P < .001). Only 3 (7%) of these 41 patients failed and were converted to a total hip replacement (THR); however, patients who did not have an established diagnosis (n = 27) before undergoing hip arthroscopy showed statistical worsening of the WOMAC (15 to 21, P = .002). Ten (37%) of these 27 patients without a diagnosis failed and needed to be converted to a THR. A significant correlation was found between the collections found on ultrasound (psoas bursa and/or in the hip joint) and the need for synovectomy (P = .01). The overall revision rate to THR after hip resurfacing in our group of patients was 1.3% (n = 13). Female patients were more likely to require postresurfacing hip arthroscopy with 42 (60%) female to only 26 (40%) male patients undergoing this procedure. In our study population, 70% (14/21, P < .05) of patients with hip pain caused by severe metal synovial reaction or metal-on-metal reaction were women. A total of 5 (7%) patients had minor-to-mild complications after hip arthroscopy. Hip arthroscopy is a safe surgical treatment option for those patients with a painful hip resurfacing arthroplasty. Having an accurate diagnosis before hip arthroscopy improves the likelihood a good outcome. Level IV - therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  19. Perioperative morbidity and mortality of total hip replacement in liver transplant recipients: a 7-year single-center experience.

    PubMed

    Aminata, Iman; Lee, Soo-Ho; Chang, Jae-Suk; Lee, Choon-Sung; Chun, Jae-Myeung; Park, Jin-Woong; Pawaskar, Aditya; Jeon, In-Ho

    2012-12-15

    This study aims to evaluate perioperative mortality and morbidity after total hip replacement in liver transplant recipients and suggesting safety guidelines. Hip replacement surgery is one of the most common elective surgeries even for organ transplant recipients. However, there is a paucity of literature addressing the morbidity and complications of hip replacement surgery for liver transplant recipients. We analyzed retrospectively 33 arthroplasty cases in 20 liver transplant recipients carried out in a single center from 2005 to 2011. All perioperative clinical and laboratory data were evaluated together with early and late morbidity and mortality. Of 2253 liver transplant recipients, 20 (0.9%) patients underwent 33 total hip arthroplasties. Thirty-two arthroplasties were performed for avascular necrosis of the femoral head, whereas only one was performed for osteoarthritis. There was no death, liver failure, or infection within 30 days after surgery. Three patients showed elevated liver enzyme more than 5 times the normal value, but it eventually decreased to normal within 1 week. Of 33 cases of arthroplasty, postoperative blood transfusion was needed in 14 cases with 1 case receiving more than 4 U. On long-term follow-up, no patients have developed periprosthetic fracture, implant loosening, or liver failure. All patients showed good to excellent postoperative Harris hip score. In this series, we can infer that hip replacement surgery in liver transplantation patients is safe and gives a reliably good result. Some preoperative conditions should be obtained to reduce postoperative morbidity.

  20. Prospective analyses of female urinary incontinence symptoms following total hip arthroplasty.

    PubMed

    Okumura, Keiko; Yamaguchi, Kumiko; Tamaki, Tatsuya; Oinuma, Kazuhiro; Tomoe, Hikaru; Akita, Keiichi

    2017-04-01

    Some patients with hip osteoarthritis report that urinary incontinence (UI) is improved following total hip arthroplasty (THA). However, the type and severity of UI remain unclear. In this study, we hypothesize that both stress urinary incontinence (SUI) and urge urinary incontinence (UUI) are improved after THA. We assess the characteristics of UI and discuss the anatomical factors related to UI and THA for improved treatment outcome. Fifty patients with UI who underwent direct anterior-approach THA were evaluated. Type of UI was assessed using four questionnaires: Core Lower Urinary Tract Symptom Score (CLSS), Urogenital Distress Inventory Short Form (UDI-6), International Prostate Symptom Score (IPSS), and Overactive Bladder Symptom Score (OABSS). Uroflowmetry and postvoid residual urine were measured using ultrasound technology. Hip-joint function was evaluated using Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM). Of the 50 patients, 21 had SUI, 16 had mixed urinary incontinence (MUI), and eight had urgency urinary incontinence (UUI). In total, 36 patients were better than improved (72 %). The rate of cured and improved was 76 % for SUI, 100 % MUI, and 50 % UUI. The improvement of ROM was more significant in cured or improved patients than in stable or worse patients. Improvement in mild UI may be an added benefit for those undergoing THA for hip-joint disorders. These data suggest that for patients with hip-joint disorder, hip-joint treatment could prove to also be a useful treatment for UI.

  1. Association between contact hip stress and RSA-measured wear rates in total hip arthroplasties of 31 patients.

    PubMed

    The, Bertram; Hosman, Anton; Kootstra, Johan; Kralj-Iglic, Veronika; Flivik, Gunnar; Verdonschot, Nico; Diercks, Ron

    2008-01-01

    The main concern in the long run of total hip replacements is aseptic loosening of the prosthesis. Optimization of the biomechanics of the hip joint is necessary for optimization of long-term success. A widely implementable tool to predict biomechanical consequences of preoperatively planned reconstructions still has to be developed. A potentially useful model to this purpose has been developed previously. The aim of this study is to quantify the association between the estimated hip joint contact force by this biomechanical model and RSA-measured wear rates in a clinical setting. Thirty-one patients with a total hip replacement were measured with RSA, the gold standard for clinical wear measurements. The reference examination was done within 1 week of the operation and the follow-up examinations were done at 1, 2 and 5 years. Conventional pelvic X-rays were taken on the same day. The contact stress distribution in the hip joint was determined by the computer program HIPSTRESS. The procedure for the determination of the hip joint contact stress distribution is based on the mathematical model of the resultant hip force in the one-legged stance and the mathematical model of the contact stress distribution. The model for the force requires as input data, several geometrical parameters of the hip and the body weight, while the model for stress requires as input data, the magnitude and direction of the resultant hip force. The stress distribution is presented by the peak stress-the maximal value of stress on the weight-bearing area (p(max)) and also by the peak stress calculated with respect to the body weight (p(max)/W(B)) which gives the effect of hip geometry. Visualization of the relations between predicted values by the model and the wear at different points in the follow-up was done using scatterplots. Correlations were expressed as Pearson r values. The predicted p(max) and wear were clearly correlated in the first year post-operatively (r = 0.58, p = 0.002), while this correlation is weaker after 2 years (r = 0.19, p = 0.337) and 5 years (r = 0.24, p = 0.235). The wear values at 1, 2 and 5 years post-operatively correlate with each other in the way that is expected considering the wear velocity curve of the whole group. The correlation between the predicted p(max) values of two observers who were blinded for each other's results was very good (r = 0.93, p < 0.001). We conclude that the biomechanical model used in this paper provides a scientific foundation for the development of a new way of constructing preoperative biomechanical plans for total hip replacements.

  2. Effect of Body Mass Index on Complications and Reoperations After Total Hip Arthroplasty.

    PubMed

    Wagner, Eric R; Kamath, Atul F; Fruth, Kristin M; Harmsen, William S; Berry, Daniel J

    2016-02-03

    High body mass index (BMI) is associated with increased rates of complications after total hip arthroplasty. Studies to date have evaluated risk mainly as a dichotomous variable according to BMI thresholds. The purpose of this paper was to characterize the risk of complications and implant survival according to BMI as a continuous variable. Using prospectively collected data from our institutional total joint registry, we analyzed 21,361 consecutive hips (17,774 patients) treated with primary total hip arthroplasty between 1985 and 2012 at a single institution. The average BMI at the time of surgery was 28.7 kg/m(2) (range, 15 to 69 kg/m(2)). Estimates of revision surgery and common complications associated with BMI were analyzed using the Kaplan-Meier method of assessing survivorship, with associations of outcomes assessed using a Cox model. Utilizing smoothing spline parameterization, we found that reoperation (p < 0.001) and implant revision or removal rates (p = 0.002) increased with increasing BMI. Increasing BMI was associated with increased rates of early hip dislocation (p = 0.02), wound infection, and, most strikingly, deep periprosthetic infection (a hazard ratio of 1.09 per unit of BMI >25 kg/m(2); p < 0.001). However, we found no association between increasing BMI and any revision for mechanical failure of the implant or between increasing BMI and revision for aseptic implant loosening. There was an inverse correlation between increasing BMI and risk of revision for bearing wear. The rates of reoperation, implant revision or removal, and common complications after total hip arthroplasty were strongly associated with BMI. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  3. Formal Physical Therapy After Total Hip Arthroplasty Is Not Required: A Randomized Controlled Trial.

    PubMed

    Austin, Matthew S; Urbani, Brian T; Fleischman, Andrew N; Fernando, Navin D; Purtill, James J; Hozack, William J; Parvizi, Javad; Rothman, Richard H

    2017-04-19

    The value of formal physical therapy after total hip arthroplasty is unknown. With substantial changes that have occurred in surgical and anesthesia techniques, self-directed therapy may be efficacious in restoring function to patients undergoing total hip arthroplasty. We conducted a single-center, randomized trial of 120 patients undergoing primary, unilateral total hip arthroplasty who were eligible for direct home discharge. The experimental group followed a self-directed home exercise program for 10 weeks. The control group received the standard protocol for physical therapy that included in-home visits with a physical therapist for the first 2 weeks followed by formal outpatient physical therapy for 8 weeks. Functional outcomes were measured using validated instruments including the Harris hip score (HHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the Short Form-36 Health Survey (SF-36) preoperatively, at 1 month postoperatively, and at 6 to 12 months postoperatively. Of 120 randomized patients, 108 were included in the final analysis. Ten patients (19%) were randomized to unsupervised home exercise and 20 patients (37%) were randomized to formal outpatient therapy crossed over between groups. There was no significant difference in any of the measured functional outcomes between patients receiving formal therapy (n = 54) and those participating in unsupervised home exercise (n = 54) at any time point (HHS, p = 0.82; WOMAC, p = 0.80; and SF-36 physical health, p = 0.90). This randomized trial suggests that unsupervised home exercise is both safe and efficacious for a majority of patients undergoing total hip arthroplasty, and formal physical therapy may not be required. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  4. Simulated studies of wear and friction in total hip prosthesis components with various ball sizes and surface finishes

    NASA Technical Reports Server (NTRS)

    Swikert, M. A.; Johnson, R. L.

    1976-01-01

    Experiments were conducted on a newly designed total hip joint simulator. The apparatus closely simulates the complex motions and loads of the human hip in normal walking. The wear and friction of presently used appliance configurations and materials were determined. A surface treatment of the metal femoral ball specimens was applied to influence wear. The results of the investigation indicate that wear can be reduced by mechanical treatment of metal femoral ball surfaces. A metallographic examination and surface roughness measurements were made.

  5. The effect of education and supervised exercise vs. education alone on the time to total hip replacement in patients with severe hip osteoarthritis. A randomized clinical trial protocol.

    PubMed

    Jensen, Carsten; Roos, Ewa M; Kjærsgaard-Andersen, Per; Overgaard, Søren

    2013-01-14

    The age- and gender-specific incidence of total hip replacement surgery has increased over the last two decades in all age groups. Recent studies indicate that non-surgical interventions are effective in reducing pain and disability, even at later stages of the disease when joint replacement is considered. We hypothesize that the time to hip replacement can be postponed in patients with severe hip osteoarthritis following participation in a patient education and supervised exercise program when compared to patients receiving patient education alone. A prospective, blinded, parallel-group multi-center trial (2 sites), with balanced randomization [1:1]. Patients with hip osteoarthritis and an indication for hip replacement surgery, aged 40 years and above, will be consecutively recruited and randomized into two treatment groups. The active treatment group will receive 3 months of supervised exercise consisting of 12 sessions of individualized, goal-based neuromuscular training, and 12 sessions of intensive resistance training plus patient education (3 sessions). The control group will receive only patient education (3 sessions). The primary end-point for assessing the effectiveness of the intervention is 12 months after baseline. However, follow-ups will also be performed once a year for at least 5 years. The primary outcome measure is the time to hip replacement surgery measured on a Kaplain-Meier survival curve from time of inclusion. Secondary outcome measures are the five subscales of the Hip disability and Osteoarthritis Outcome Score, physical activity level (UCLA activity score), and patient's global perceived effect. Other measures include pain after exercise, joint-specific adverse events, exercise adherence, general health status (EQ-5D-5L), mechanical muscle strength and performance in physical tests. A cost-effectiveness analysis will also be performed. To our knowledge, this is the first randomized clinical trial comparing a patient education plus supervised exercise program to patient education alone in hip osteoarthritis patients with an indication for surgery on the time to total hip replacement. NCT01697241.

  6. Ultrasound-guided Radiofrequency Lesioning of the Articular Branches of the Femoral Nerve for the Treatment of Chronic Post-arthroplasty Hip Pain.

    PubMed

    Kim, David J; Shen, Shiqian; Hanna, George M

    2017-02-01

    Total hip arthroplasty (THA) is a common surgical treatment for several conditions of the hip. While the majority of patients obtain satisfactory results, many develop chronic post-arthroplasty hip pain that can be difficult to treat. We evaluate the effectiveness of cooled (60°C) radiofrequency lesioning of the articular branches of the femoral nerve (ABFN) as a minimally invasive treatment for patients suffering from chronic post-arthroplasty hip pain. This treatment has never been described previously in this population. Case report. Center for Pain Medicine, Massachusetts General Hospital, Harvard Medical School. A 59-year-old woman with long-standing osteoarthritis of the right hip who underwent primary total hip arthroplasty and presented with chronic post-arthroplasty hip pain Intervention: Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance Outcome Measure: Functional ability and numeric rating scale (NRS) scores at rest and with activity. Prior to intervention, the patient reported severe disruption in daily activities, sleep, and relationships; NRS scores at rest and with activity were 4/10 and 10/10, respectively. At 4 weeks following intervention, the patient reported significant improvement in functional ability and NRS scores decreased to 1/10 and 2/10, respectively. At 6 months, the patient's NRS scores at rest and with activity were 0/10 and 1/10, respectively. At 24-month follow-up, the patient continued to endorse significant pain relief with NRS scores at rest and with activity of 0 - 1/10 and 1 - 2/10, respectively. There were no side effects or complications including motor weakness, sensory loss, and neuralgias. Although the patient obtained good results from the intervention, the description of the study is from a single case report. Further study is necessary to investigate the widespread use of this technique and its outcomes. Cooled (60°C) radiofrequency lesioning of the ABFN under ultrasound guidance is both an effective and minimally invasive intervention for chronic post-arthroplasty hip pain. Key words: Radiofrequency lesioning, articular branches, femoral nerve, post-arthoplasty, total hip arthoplasty, hip pain, chronic pain.

  7. [Unusual infection complication of total hip arthroplasty].

    PubMed

    Jány, R; Vojtassák, J; Lisý, M; Almási, J

    2005-01-01

    Authors present the case history of a 66-year old patient after repeated reimplantations of the THA with a deep infect caused by a rare aetiological agent (Serratia marcescens) associated with a pyogenic sinus. They describe the disease history, therapeutic procedure, complications associated with the surgery as well as postoperative course after the reimplantation of a customized total hip replacement. In the conclusion they state that in case of an infected total hip arthroplasty the treatment is focused on the salvage of the infection process and preservation of the function of the affected limb. Of essential importance is surgical revision with a radical removal of necrotic tissues and hardware in combination with an intensive parenteral antibiotic administration.

  8. Management of osteonecrosis of the femoral head in children with sickle cell disease: results of conservative and operative treatments at skeletal maturity.

    PubMed

    Mallet, C; Abitan, A; Vidal, C; Holvoet, L; Mazda, K; Simon, A-L; Ilharreborde, B

    2018-02-01

    Sickle cell disease (SCD) is the most common cause of femoral head osteonecrosis (ONFH) during childhood with an overall prevalence of 10%. In children, spontaneous revascularization can occur, as in Legg-Calve-Perthes disease. Consequently, the aim of treatment is to restore proper hip containment to prevent joint arthritis. This is the first study reporting long-term results at skeletal maturity of non-operative and surgical treatments for ONFH in SCD children. All children with ONFH due to SCD were retrospectively reviewed. At initial evaluation, extension of osteonecrosis was radiographically defined using Catterall, lateral pillar Herring and Ficat classifications. Subluxation of the femoral head with Reimers migration index > 30% required surgical treatment including femoral varus osteotomy and/or pelvic osteotomies. Conservative treatment including non-weight bearing and physiotherapy was performed in the remaining cases. Outcomes were assessed at skeletal maturity using the Harris Hip Score (HHS) and the Stulberg classification. Total hip arthroplasty and Stulberg 5 were defined as failures. A total of 25 hips in 17 patients were included (mean follow-up 7.5 years SD 3.4). Mean age at diagnosis was 11.4 years SD 2.9. In all, 15 hips (60%) were classified Catterall 3 and 4 and Herring B and C. A total of 13 patients (52%) underwent surgical treatment. At skeletal maturity, mean HHS was good (81 SD 17), 12 hips (48%) were classified Stulberg 1 and 2, seven hips (28%) were classified Stulberg 3 and 4. Both treatments led to good functional results with 75% of congruent hips at skeletal maturity. IV.

  9. Management of osteonecrosis of the femoral head in children with sickle cell disease: results of conservative and operative treatments at skeletal maturity

    PubMed Central

    Mallet, C.; Abitan, A.; Vidal, C.; Holvoet, L.; Mazda, K.; Simon, A.-L.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Sickle cell disease (SCD) is the most common cause of femoral head osteonecrosis (ONFH) during childhood with an overall prevalence of 10%. In children, spontaneous revascularization can occur, as in Legg-Calve-Perthes disease. Consequently, the aim of treatment is to restore proper hip containment to prevent joint arthritis. This is the first study reporting long-term results at skeletal maturity of non-operative and surgical treatments for ONFH in SCD children. Methods All children with ONFH due to SCD were retrospectively reviewed. At initial evaluation, extension of osteonecrosis was radiographically defined using Catterall, lateral pillar Herring and Ficat classifications. Subluxation of the femoral head with Reimers migration index > 30% required surgical treatment including femoral varus osteotomy and/or pelvic osteotomies. Conservative treatment including non-weight bearing and physiotherapy was performed in the remaining cases. Outcomes were assessed at skeletal maturity using the Harris Hip Score (HHS) and the Stulberg classification. Total hip arthroplasty and Stulberg 5 were defined as failures. Results A total of 25 hips in 17 patients were included (mean follow-up 7.5 years SD 3.4). Mean age at diagnosis was 11.4 years SD 2.9. In all, 15 hips (60%) were classified Catterall 3 and 4 and Herring B and C. A total of 13 patients (52%) underwent surgical treatment. At skeletal maturity, mean HHS was good (81 SD 17), 12 hips (48%) were classified Stulberg 1 and 2, seven hips (28%) were classified Stulberg 3 and 4. Conclusion Both treatments led to good functional results with 75% of congruent hips at skeletal maturity. Level of Evidence IV PMID:29456754

  10. Survivorship analysis of failure pattern after revision total hip arthroplasty.

    PubMed

    Retpen, J B; Varmarken, J E; Jensen, J S

    1989-12-01

    Failure, defined as established indication for or performed re-revision of one or both components, was analyzed using survivorship methods in 306 revision total hip arthroplasties. The longevity of revision total hip arthroplasties was inferior to that of previously reported primary total hip arthroplasties. The overall survival curve was two-phased, with a late failure period associated with aseptic loosening of one or both components and an early failure period associated with causes of failure other than loosening. Separate survival curves for aseptic loosening of femoral and acetabular components showed late and almost simultaneous decline, but with a tendency toward a higher rate of failure for the femoral component. No differences in survival could be found between the Stanmore, Lubinus standard, and Lubinus long-stemmed femoral components. A short interval between the index operation and the revision and intraoperative and postoperative complications were risk factors for early failure. Young age was a risk factor for aseptic loosening of the femoral component. Intraoperative fracture of the femoral shaft was not a risk factor for secondary loosening. No difference in survival was found between primary cemented total arthroplasty and primary noncemented hemiarthroplasty.

  11. Usefulness of postoperative hip irradiation in the prevention of heterotopic bone formation in a high risk group of patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacLennan, I.; Keys, H.M.; Evarts, C.M.

    1984-01-01

    Heterotopic ossification is a complication of total hip arthroplasty in 14 to 30% of patients. Significant functional impairment will occur in up to 28% of patients with ectopic bone. The high risk group includes those with preexisting heterotopic bone in either hip, those suffering from hypertrophic osteoarthritis or ankylosing spondylitis and patients who have had multiple procedures on the hip. Fifty-eight patients (67 hips) were irradiated after surgical removal of ectopic bone (53 hips) or received radiation prophylaxis of heterotopic ossification (14 hips). Ninety-five percent of patients had either no bone visible or insignificant amounts of ectopic bone visible onmore » postoperative hip X-rays. Only 5% of patients showed significant persistence of ectopic bone. Postoperative hip function was dramatically improved compared to preoperative function in all patients treated. The importance of early commencement of irradiation is emphasized.« less

  12. Dynamic Hip Kinematics During the Golf Swing After Total Hip Arthroplasty.

    PubMed

    Hara, Daisuke; Nakashima, Yasuharu; Hamai, Satoshi; Higaki, Hidehiko; Ikebe, Satoru; Shimoto, Takeshi; Yoshimoto, Kensei; Iwamoto, Yukihide

    2016-07-01

    Although most surgeons allow their patients to play golf after total hip arthroplasty (THA), the effect on the implant during the golf swing is still unclear. To evaluate hip kinematics during the golf swing after THA. Descriptive laboratory study. Eleven hips in 9 patients who underwent primary THA were analyzed. All patients were right-handed recreational golfers, and these 11 hips included 6 right hips and 5 left hips. Periodic radiographic images of the golf swing were taken using a flat-panel x-ray detector. Movements of the hip joint and components were assessed using 3-dimensional-to-2-dimensional model-to-image registration techniques. Liner-to-neck contact and translation of the femoral head with respect to the acetabular cup (cup-head translation) were examined. Hip kinematics, orientation of components, and maximum cup-head translation were compared between patients with and without liner-to-neck contact. On average, the golf swing produced approximately 50° of axial rotation in both lead and trail hips. Liner-to-neck contact was observed in 4 hips with elevated rim liners (2 lead hips and 2 trail hips) at maximum external rotation. Neither bone-to-bone nor bone-to-implant contact was observed at any phases of the golf swing in any of the hips. Four hips with liner-to-neck contact had significantly larger maximum external rotation (37.9° ± 7.0° vs 20.6° ± 9.9°, respectively; P = .01) and more cup anteversion (26.5° ± 6.1° vs 10.8° ± 8.9°, respectively; P = .01) than hips without liner-to-neck contact. No significant differences between hips with and without contact were found for cup inclination (42.0° ± 2.5° vs 38.1° ± 5.5°, respectively; P = .22), combined anteversion (45.3° ± 8.9° vs 51.4° ± 7.9°, respectively; P = .26), or maximum cup-head translation (1.3 ± 0.3 mm vs 1.5 ± 0.4 mm, respectively; P = .61). In this analysis, the golf swing did not produce excessive hip rotation or cup-head translation in any hips. However, liner-to-neck contact during the golf swing was observed in 36% of the hips, with unknown effects on the long-term results. Golf is an admissible sport after THA because dynamic hip stability was observed. However, the implant position, especially cup anteversion and the use of elevated rim liners, promoted liner-to-neck contact. © 2016 The Author(s).

  13. A comparison of regional and general anaesthesia for total replacement of the hip or knee: a meta-analysis.

    PubMed

    Hu, S; Zhang, Z-Y; Hua, Y-Q; Li, J; Cai, Z-D

    2009-07-01

    We performed a meta-analysis to evaluate the relative efficacy of regional and general anaesthesia in patients undergoing total hip or knee replacement. A comprehensive search for relevant studies was performed in PubMed (1966 to April 2008), EMBASE (1969 to April 2008) and the Cochrane Library. Only randomised studies comparing regional and general anaesthesia for total hip or knee replacement were included. We identified 21 independent, randomised clinical trials. A random-effects model was used to calculate all effect sizes. Pooled results from these trials showed that regional anaesthesia reduces the operating time (odds ratio (OR) -0.19; 95% confidence interval (CI) -0.33 to -0.05), the need for transfusion (OR 0.45; 95% CI 0.22 to 0.94) and the incidence of thromboembolic disease (deep-vein thrombosis OR 0.45, 95% CI 0.24 to 0.84; pulmonary embolism OR 0.46, 95% CI 0.29 to 0.80). Regional anaesthesia therefore seems to improve the outcome of patients undergoing total hip or knee replacement.

  14. Basic Science Considerations in Primary Total Hip Replacement Arthroplasty

    PubMed Central

    Mirza, Saqeb B; Dunlop, Douglas G; Panesar, Sukhmeet S; Naqvi, Syed G; Gangoo, Shafat; Salih, Saif

    2010-01-01

    Total Hip Replacement is one of the most common operations performed in the developed world today. An increasingly ageing population means that the numbers of people undergoing this operation is set to rise. There are a numerous number of prosthesis on the market and it is often difficult to choose between them. It is therefore necessary to have a good understanding of the basic scientific principles in Total Hip Replacement and the evidence base underpinning them. This paper reviews the relevant anatomical and biomechanical principles in THA. It goes on to elaborate on the structural properties of materials used in modern implants and looks at the evidence base for different types of fixation including cemented and uncemented components. Modern bearing surfaces are discussed in addition to the scientific basis of various surface engineering modifications in THA prostheses. The basic science considerations in component alignment and abductor tension are also discussed. A brief discussion on modular and custom designs of THR is also included. This article reviews basic science concepts and the rationale underpinning the use of the femoral and acetabular component in total hip replacement. PMID:20582240

  15. Cell therapy versus simultaneous contralateral decompression in symptomatic corticosteroid osteonecrosis: a thirty year follow-up prospective randomized study of one hundred and twenty five adult patients.

    PubMed

    Hernigou, Philippe; Dubory, Arnaud; Homma, Yasuhiro; Guissou, Isaac; Flouzat Lachaniette, Charles Henri; Chevallier, Nathalie; Rouard, Hélène

    2018-05-09

    Symptomatic osteonecrosis related to corticosteroids has a high risk of progression to collapse in absence of treatment. The purposes of this study were to evaluate the results of autologous bone marrow grafting of the symptomatic hip in adult patients with osteonecrosis and to compare the results with core decompression alone in the contralateral symptomatic hip. A total of 125 consecutive patients (78 males and 47 females) with bilateral osteonecrosis (ON) and who had both hips symptomatic and at the same stage on each side (stage I or II) were included in this study from 1988 to 1998. The volume of osteonecrosis was measured with MRI in both hips; the smaller size ON was treated with core decompression, and the contralateral hip with the larger ON was treated with percutaneous mesenchymal cell (MSC) injection obtained from bone marrow concentration. The average total number of MSCs (counted as number of colony forming units-fibroblast) injected in each hip was 90,000 ± 25,000 cells (range 45,000 to 180,000 cells). At the most recent FU (average 25 years after the first surgery, range 20 to 30 years), among the 250 hips included in the study, 35 hips (28%) had collapsed at the most recent follow-up after bone marrow grafting, and 90 (72%) after core decompression (CD). Ninety-five hips (76%) in the CD group underwent total hip replacement and 30 hips (24%) in the bone marrow graft group (p < 0.0001). Hips undergoing only CD were approximately three times more likely to undergo a primary THA (odds ratio: 10.0278; 95% CI: 5.6117 to 17.9190; p < 0.0001) as compared with hips undergoing an initial bone marrow grafting. For the 90 hips treated with bone marrow injection and without collapse, the mean volume of repair evaluated by MRI at the most recent follow-up was 16.4 cm 3 (range 12 to 21 cm 3 ) corresponding to a decrease of the pre-operative average volume from 22.4 cm 3 (range 35-15 cm 3 ) to 6 cm 3 (range 12-0 cm 3 ); as percentage of the volume of the femoral head, the decrease moved from 44.8 to 12%. Core decompression with bone marrow injection improved the outcome of the disease as compared with core decompression alone in the same patient.

  16. Effects of the Length of Stay on the Cost of Total Knee and Total Hip Arthroplasty from 2002 to 2013.

    PubMed

    Molloy, Ilda B; Martin, Brook I; Moschetti, Wayne E; Jevsevar, David S

    2017-03-01

    Utilization of total knee and hip arthroplasty has greatly increased in the past decade in the United States; these are among the most expensive procedures in patients with Medicare. Advances in surgical techniques, anesthesia, and care pathways decrease hospital length of stay. We examined how trends in hospital cost were altered by decreases in length of stay. Procedure, demographic, and economic data were collected on 6.4 million admissions for total knee arthroplasty and 2.8 million admissions for total hip arthroplasty from 2002 to 2013 using the National (Nationwide) Inpatient Sample, a component of the Healthcare Cost and Utilization Project. Trends in mean hospital costs and their association with length of stay were estimated using inflation-adjusted, survey-weighted generalized linear regression models, controlling for patient demographic characteristics and comorbidity. From 2002 to 2013, the length of stay decreased from a mean time of 4.06 to 2.97 days for total knee arthroplasty and from 4.06 to 2.75 days for total hip arthroplasty. During the same time period, the mean hospital cost for total knee arthroplasty increased from $14,988 (95% confidence interval [CI], $14,927 to $15,049) in 2002 to $22,837 (95% CI, $22,765 to $22,910) in 2013 (an overall increase of $7,849 or 52.4%). The mean hospital cost for total hip arthroplasty increased from $15,792 (95% CI, $15,706 to $15,878) in 2002 to $23,650 (95% CI, $23,544 to $23,755) in 2013 (an increase of $7,858 or 49.8%). If length of stay were set at the 2002 mean, the growth in cost for total knee arthroplasty would have been 70.8% instead of 52.4% as observed, and the growth in cost for total hip arthroplasty would have been 67.4% instead of 49.8% as observed. Hospital costs for joint replacement increased from 2002 to 2013, but were attenuated by reducing inpatient length of stay. With demographic characteristics showing an upward trend in the utilization of joint arthroplasty, including a shift toward younger population groups, reduction in length of stay remains an important target for procedure-level cost containment under emerging payment models.

  17. Evidence to suggest that women's sexual behavior is influenced by hip width rather than waist-to-hip ratio.

    PubMed

    Simpson, Victoria J; Brewer, Gayle; Hendrie, Colin A

    2014-10-01

    Waist-to-hip ratio (WHR) is an important ornament display that signals women's health and fertility. Its significance derives from human development as a bipedal species. This required fundamental changes to hip morphology/musculature to accommodate the demands of both reproduction and locomotion. The result has been an obstetric dilemma whereby women's hips are only just wide enough to allow the passage of an infant. Childbirth therefore poses a significant hip width related threat to maternal mortality/risk of gynecological injury. It was predicted that this would have a significant influence on women's sexual behavior. To investigate this, hip width and WHR were measured in 148 women (M age = 20.93 + 0.17 years) and sexual histories were recorded via questionnaire. Data revealed that hip width per se was correlated with total number of sexual partners, total number of one night stands, percentage of sexual partners that were one night stands, number of sexual partners within the context of a relationship per year sexually active, and number of one night stands per year sexually active. By contrast, WHR was not correlated with any of these measures. Further analysis indicated that women who predominantly engaged in one night stand behavior had wider hips than those who did not. WHR was again without effect in this context. Women's hip morphology has a direct impact on their risk of potentially fatal childbirth related injury. It is concluded that when they have control over this, women's sexual behavior reflects this risk and is therefore at least in part influenced by hip width.

  18. Hip arthroscopy in patients with recurrent pain following Bernese periacetabular osteotomy for acetabular dysplasia: operative findings and clinical outcomes

    PubMed Central

    Cvetanovich, Gregory L.; Heyworth, Benton E.; Murray, Kerri; Yen, Yi-Meng; Kocher, Mininder S.; Millis, Michael B.

    2015-01-01

    To report the operative findings and outcomes of hip arthroscopy for recurrent pain following periacetabular osteotomy (PAO) for acetabular dysplasia. A departmental database was used to identify patients who underwent hip arthroscopy following PAO between 2000 and 2009. Demographic data, arthroscopic findings, functional outcome scores and patient satisfaction were analysed. Of 556 PAO patients, 17 hips in 16 patients (3.1%) underwent post-PAO hip arthroscopy. Mean age at PAO was 23.8 years, and mean age at arthroscopy was 27.0 years. Common hip arthroscopy findings included labral tears (13 hips, 81.3%), significant (≥grade 2) chondral changes (12 hips, 75%), cam impingement (7 hips, 43.8%) and pincer impingement (6 hips, 37.5%). At mean follow-up 2.8 years after arthroscopy, additional procedures had been performed in six hips (37.5%), including total hip arthroplasty in one hip. Post-PAO arthroscopy questionnaire revealed 85.7% of patients with improved hip pain, 57.1% improved hip stiffness and 57.1% improved hip function. There was no significant difference in functional outcome measures. Common post-PAO hip arthroscopy findings include labral tears, chondral changes and femoroacetabular impingement. Many patients reported subjective hip improvement from post-PAO arthroscopy, but hip outcome scores were unchanged and one-third of patients had further surgery. PMID:27011852

  19. Comparison of two different rehabilitation programmes for thrust plate prosthesis: a randomized controlled study.

    PubMed

    Unver, Bayram; Karatosun, Vasfi; Gunal, Izge; Angin, Salih

    2004-02-01

    Weight bearing after total hip arthroplasty is postponed in order to prevent early loosening, but this negatively affects the rehabilitation programme. For the force transfer characteristics of thrust plate prosthesis (TPP), a new type of hip prosthesis used without cement is similar to the normal hip. We evaluated the possibilities of early weight bearing after TPP by comparing early partial with early full weight bearing. Randomized controlled study. Department of orthopaedics and traumatology in a university hospital. Sixty hips of 51 patients who underwent total hip arthroplasty with TPP were randomly assigned into two groups. Both groups received accelerated rehabilitation programmes: group 1 with early partial weight bearing and group 2 with early full weight bearing. Patients were evaluated by a blind observer preoperatively, at three months after surgery by clinical (measurement of range of hip motion (universal goniometry), muscle strength (Manual Muscle Test), functional test (6-minute walk test), hip function (Harris Hip Scoring System)) and radiographical parameters and one year after surgery by clinical (Harris Hip Scoring System) and radiographical parameters. Group 2 performed transfer activities earlier, had more walking distance at the time of discharge and shorter hospital stay than group 1. At three months, Harris Hip Score, muscle strength, 6-minute walk test, and duration of crutch use were significantly (p < 0.05) in favour of group 2. None of the patients in either group showed signs of loosening one year after the operation. These results suggest that patients with TPP can tolerate an accelerated rehabilitation programme with early weight bearing and will gain the goals of rehabilitation earlier.

  20. A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

    PubMed

    Ogawa, Hiroyuki; Hasegawa, Seiichirou; Tsukada, Sachiyuki; Matsubara, Masaaki

    2018-06-01

    We developed an acetabular cup placement device, the AR-HIP system, using augmented reality (AR). The AR-HIP system allows the surgeon to view an acetabular cup image superimposed in the surgical field through a smartphone. The smartphone also shows the placement angle of the acetabular cup. This preliminary study was performed to assess the accuracy of the AR-HIP system for acetabular cup placement during total hip arthroplasty (THA). We prospectively measured the placement angles using both a goniometer and AR-HIP system in 56 hips of 54 patients undergoing primary THA. We randomly determined the order of intraoperative measurement using the 2 devices. At 3 months after THA, the placement angle of the acetabular cup was measured on computed tomography images. The primary outcome was the absolute value of the difference between intraoperative and postoperative computed tomography measurements. The measurement angle using AR-HIP was significantly more accurate in terms of radiographic anteversion than that using a goniometer (2.7° vs 6.8°, respectively; mean difference 4.1°; 95% confidence interval, 3.0-5.2; P < .0001). There was no statistically significant difference in terms of radiographic inclination (2.1° vs 2.6°; mean difference 0.5°; 95% confidence interval, -1.1 to 0.1; P = .13). In this pilot study, the AR-HIP system provided more accurate information regarding acetabular cup placement angle than the conventional method. Further studies are required to confirm the utility of the AR-HIP system as a navigation tool. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Patient-oriented functional results of total femoral endoprosthetic reconstruction following oncologic resection.

    PubMed

    Jones, Kevin B; Griffin, Anthony M; Chandrasekar, Coonoor R; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S; Grimer, Robert J; Wunder, Jay S; Ferguson, Peter C

    2011-11-01

    Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Fifty-four TFR patients were identified from three institutional prospective databases. Forty-one had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n = 27 were compared between groups and to cohorts of PFR (n = 31) and DFR (n = 85) patients using the Mann-Whitney U-test. Follow-up averaged 4 years. Mechanical complications included five hip dislocations and one femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3 ± 17.8, statistically decreased from DFR (P = 0.002) and PFR patients (P = 0.036). No significant differences were detected between patients in the fixed-hinge (n = 18) and rotating-hinge (n = 9) groups (P = 0.944), or total hip (n = 8) and hemiarthroplasty (n = 19) groups (P = 0.633). TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. Copyright © 2011 Wiley Periodicals, Inc.

  2. Extended application of WISH type S-form hip brace for patients with bilateral painful hip osteoarthritis: report of two cases.

    PubMed

    Sato, Takahisa; Yamaji, Takehiko; Inose, Hideyuki; Sato, Ena; Yoshikawa, Ayako; Usuda, Shigeru; Watanabe, Hideomi

    2009-06-01

    Dynamic lateral instability of the femoral head develops in patients with osteoarthritis (OA) of the hip. Recently we have developed a hip brace, called the WISH-type hip brace, and showed successful response of the patients quantitatively. However, a negligible effect was observed in patients with bilateral involvement. Here, we extended the application of the WISH-type hip brace for two patients with bilateral OA joints. The resultant WISH-type hip brace with two S-form portions for bilateral thighs provided good recovery in hip function. Interestingly Timed Up & Go (TUG) test performed for one patient revealed a positive effect of the brace on the functional mobility. To the best of our knowledge, this is the first report elucidating the therapeutic effect of brace therapy with bilateral hip stabilization from hip functional and functional mobility points of view. Application of the present brace should be taken into account for patients with painful bilateral hip OA before easy application of invasive surgery such as total hip arthroplasty.

  3. UEFA injury study: a prospective study of hip and groin injuries in professional football over seven consecutive seasons.

    PubMed

    Werner, J; Hägglund, M; Waldén, M; Ekstrand, J

    2009-12-01

    Groin injury is a common injury in football and a complicated area when it comes to diagnosis and therapy. There is a lack of comprehensive epidemiological data on groin injuries in professional football. To investigate the incidence, pattern and severity of hip and groin injuries in professional footballers over seven consecutive seasons. Prospective cohort study. European professional football. During the 2001/2 to 2007/8 seasons, between nine and 17 clubs per season (23 clubs in total) were investigated, accounting for 88 club seasons in total. Time loss injuries and individual exposure during club and national team training sessions and matches were recorded. Injury incidence. A total of 628 hip/groin injuries were recorded, accounting for 12-16% of all injuries per season. The total injury incidence was 1.1/1000 h (3.5/1000 match hours vs 0.6/1000 training hours, p<0.001) and was consistent over the seasons studied. Eighteen different diagnostic entities were registered, adductor (n = 399) and iliopsoas (n = 52) related injuries being the most common. More than half of the injuries (53%) were classified as moderate or severe (absence of more than a week), the mean absence per injury being 15 days. Reinjuries accounted for 15% of all registered injuries. In the 2005/6 to 2007/8 seasons, 41% of all diagnoses relied solely on clinical examination. Hip/groin injuries are common in professional football, and the incidence over consecutive seasons is consistent. Hip/groin injuries are associated with long absences. Many hip/groin diagnoses are based only on clinical examination.

  4. Increased Long-Term Cardiovascular Risk After Total Hip Arthroplasty

    PubMed Central

    Gordon, Max; Rysinska, Agata; Garland, Anne; Rolfson, Ola; Aspberg, Sara; Eisler, Thomas; Garellick, Göran; Stark, André; Hailer, Nils P.; Sköldenberg, Olof

    2016-01-01

    Abstract Total hip arthroplasty is a common and important treatment for osteoarthritis patients. Long-term cardiovascular effects elicited by osteoarthritis or the implant itself remain unknown. The purpose of the present study was to determine if there is an increased risk of late cardiovascular mortality and morbidity after total hip arthroplasty surgery. A nationwide matched cohort study with data on 91,527 osteoarthritis patients operated on, obtained from the Swedish Hip Arthroplasty Register. A control cohort (n = 270,688) from the general Swedish population was matched 1:3 to each case by sex, age, and residence. Mean follow-up time was 10 years (range, 7–21). The exposure was presence of a hip replacement for more than 5 years. The primary outcome was cardiovascular mortality after 5 years. Secondary outcomes were total mortality and re-admissions due to cardiovascular events. During the first 5 to 9 years, the arthroplasty cohort had a lower cardiovascular mortality risk compared with the control cohort. However, the risk in the arthroplasty cohort increased over time and was higher than in controls after 8.8 years (95% confidence interval [CI] 7.0–10.5). Between 9 and 13 years postoperatively, the hazard ratio was 1.11 (95% CI 1.05–1.17). Arthroplasty patients were also more frequently admitted to hospital for cardiovascular reasons compared with controls, with a rate ratio of 1.08 (95% CI 1.06–1.11). Patients with surgically treated osteoarthritis of the hip have an increased risk of cardiovascular morbidity and mortality many years after the operation when compared with controls. PMID:26871792

  5. 3D printing technology used in severe hip deformity.

    PubMed

    Wang, Shanshan; Wang, Li; Liu, Yan; Ren, Yongfang; Jiang, Li; Li, Yan; Zhou, Hao; Chen, Jie; Jia, Wenxiao; Li, Hui

    2017-09-01

    This study was designed to assess the use of a 3D printing technique in total hip arthroplasty (THA) for severe hip deformities, where new and improved approaches are needed. THAs were performed from January 2015 to December 2016. Bioprosthesis artificial hip joints were used in both conventional and 3D printing hip arthroplasties. A total of 74 patients (57 cases undergoing conventional hip replacements and 17 undergoing 3D printing hip replacements) were followed-up for an average of 24 months. The average age of the patients was 62.7 years. Clinical data between the patients treated with different approaches were compared. Results showed that the time to postoperative weight bearing and the Harris scores of the patients in the 3D printing group were better than those for patients in the conventional hip replacement group. Unfortunately, the postoperative infection and loosening rates were higher in the 3D printing group. However, there were no significant differences in femoral neck anteversion, neck shaft, acetabular or sharp angles between ipsilateral and contralateral sides in the 3D printing group (P>0.05). The femoral neck anteversion angle was significantly different between the two sides in the conventional hip replacement group (P<0.05). Based on these results, we suggest that the 3D printing approach provides a better short-term curative effect that is more consistent with the physiological structure and anatomical characteristics of the patient, and we anticipate that its use will help improve the lives of many patients.

  6. MRI Evaluation of Post Core Decompression Changes in Avascular Necrosis of Hip

    PubMed Central

    Marupaka, Sravan Kumar; Alluri, Swathi; MD, Naseeruddin; Irfan, Kazi Amir; Jampala, Venkateshwarlu; Apsingi, Sunil; Eachempati, Krishna Kiran

    2015-01-01

    Introduction Avascular necrosis of hip typically presents in young patients. Core decompression in precollapse stage provides pain relief and preservation of femoral head. The results of core decompression vary considerably despite early diagnosis. The role of MRI in monitoring patients post surgically has not been clearly defined. Aim To study pre and post core decompression MRI changes in avascular necrosis of hip. Materials and Methods This is a contiguous observational cohort of 40 hips treated by core decompression for precollapse avascular necrosis of femoral head, who had a baseline MRI performed before surgery. Core decompression of the femoral head was performed within 4 weeks. Follow up radiograph and MRI scans were done at six months. Harris hip score preoperatively, 1 month and 6 months after the surgery was noted. Success in this study was defined as postoperative increase in Harris hip score (HHS) by 20 points and no additional femoral collapse. End point of clinical adverse outcome as defined by fall in Harris hip score was conversion or intention to convert to total hip replacement (THR). MRI parameters in the follow up scan were compared to the preoperative MRI. Effect of core decompression on bone marrow oedema and femoral head collapse was noted. Results were analysed using SPSS software version. Results Harris hip score improved from 57 to 80 in all patients initially. Six hips had a fall in Harris hip score to mean value of 34.1 during follow up (9 to 12 months) and underwent total hip replacement. MRI predictors of positive outcome are lesions with grade A extent, Grade A & B location. Bone marrow oedema with lesions less than 50% involvement, medial and central location. Conclusion Careful selection of patients by MR criteria for core decompression provides satisfactory outcome in precollapse stage of avascular necrosis of hip. PMID:26816966

  7. Revision Hip Arthroscopy Indications and Outcomes: A Systematic Review.

    PubMed

    Sardana, Vandit; Philippon, Marc J; de Sa, Darren; Bedi, Asheesh; Ye, Lily; Simunovic, Nicole; Ayeni, Olufemi R

    2015-10-01

    To identify the indications and outcomes in patients undergoing revision hip arthroscopy. The electronic databases Embase, Medline, HealthStar, and PubMed were searched from 1946 to July 19, 2014. Two blinded reviewers searched, screened, and evaluated the data quality of the studies using the Methodological Index for Non-Randomized Studies scale. Data were abstracted in duplicate. Agreement and descriptive statistics are presented. Six studies were included (3 prospective case series and 3 retrospective chart reviews), with a total of 448 hips examined. The most common indications for revision hip arthroscopy included residual femoroacetabular impingement (FAI), labral tears, and chondral lesions. The mean interval between revision arthroscopy and the index procedure was 25.6 months. Overall, the modified Harris Hip Score improved by a mean of 33.6% (19.3 points) from the baseline score at 1-year follow-up. In 14.6% of patients, further surgical procedures were required, including re-revision hip arthroscopy (8.0%), total hip replacement (5.6%), and hip resurfacing (1.0%). Female patients more commonly underwent revision hip arthroscopy (59.7%). The current evidence examined in this review supports revision hip arthroscopy as a successful intervention to improve functional outcomes (modified Harris Hip Score) and relieve pain in patients with residual symptoms after primary FAI surgery, although the outcomes are inferior when compared with a matched cohort of patients undergoing primary hip arthroscopy for FAI. The main indication for revision is a candidate who has symptoms due to residual cam- or pincer-type deformity that was either unaddressed or under-resected during the index operation. However, it is important to consider that the studies included in this review are of low-quality evidence. Surgeons should consider incorporating a minimum 2-year follow-up for individuals after index hip-preservation surgery because revisions tended to occur within this time frame. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Radiographic cup position following posterior and lateral approach to total hip arthroplasty. An explorative randomized controlled trial.

    PubMed

    Kruse, Christine; Rosenlund, Signe; Broeng, Leif; Overgaard, Søren

    2018-01-01

    The two most common surgical approaches to total hip arthroplasty are the posterior approach and lateral approach. The surgical approach may influence cup positioning and restoration of the offset, which may affect the biomechanical properties of the hip joint. The primary aim was to compare cup position between posterior approach and lateral approach. Secondary aims were to compare femoral offset, abductor moment arm and leg length discrepancy between the two approaches. Eighty patients with primary hip osteoarthritis were included in a randomized controlled trial and assigned to total hip arthroplasty using posterior approach or lateral approach. Postoperative radiographs from 38 patients in each group were included in this study for measurement of cup anteversion and inclination. Femoral offset, cup offset, total offset, abductor moment arm and leg length discrepancy were measured on preoperative and postoperative radiographs in 28 patients in each group. We found that mean anteversion was 5° larger in the posterior approach group (95% CI, -8.1 to -1.4; p = 0.006), while mean inclination was 5° less steep (95% CI, 2.7 to 7.2; p<0.001) compared with the lateral approach group. The posterior approach group had a larger mean femoral offset of 4.3mm (95% CI, -7.4 to -1.3, p = 0.006), mean total offset of 6.3mm (95% CI, -9.6 to -3; p<0.001) and mean abductor moment arm of 4.8mm (95% CI, -7.6 to -1.9; p = 0.001) compared with the lateral approach group. We found a larger cup anteversion but less steep cup inclination in the posterior approach group compared with the lateral approach group. Femoral offset and abductor moment arm were restored after total hip arthroplasty using lateral approach but significantly increased when using posterior approach.

  9. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis.

    PubMed

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A M; Fiorentini, Carlo E; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M

    2017-12-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year.

  10. Total Hip Arthroplasty in an Inveterate Femoral Neck Fracture in a Patient with Congenital Insensitivity to Pain with Anhidrosis

    PubMed Central

    Dagnino, Augusto; Ursino, Nicola; Ripamonti, Carlo A. M.; Fiorentini, Carlo E.; Scelsi, Michele; D'Ambrosi, Riccardo; Portinaro, Nicola M.

    2017-01-01

    Congenital insensitivity to pain with anhidrosis (CIPA) is an extremely rare disorder characterized by autonomic and sensory nerves malfunction with insensitivity to both deep and superficial painful stimuli, inability to sweat and produce tears, and mild to moderate mental retardation with self-mutilating behavior. Related consequences of inveterate musculoskeletal injuries represent a major issue for these patients, since pain cannot act as a protection mechanism. For the same reason, the patients are at risk during postoperative rehabilitation, which should be taken into account when selecting an orthopaedic implant. To our knowledge, only one case of total hip arthroplasty has been reported in the literature to date. A 21-year-old Caucasian male patient affected with CIPA arrived at our attention complaining about a functional limitation of the left hip. No history of trauma was reported. The X-rays showed an inveterate femoral neck fracture with a severe necrosis and resorption of the femoral head. We decided to perform a total hip arthroplasty with a cemented stem and a cemented dual mobility cup. The postoperative course and rehabilitation were satisfactory, with excellent clinical results, measured with the Harris Hip Score at 1 year. PMID:29270564

  11. Association Between Pseudotumor Formation and Patient Factors in Metal-on-Metal Total Hip Arthroplasty Population.

    PubMed

    Kleeman, Lindsay T; Goltz, Daniel; Seyler, Thorsten M; Mammarappallil, Joseph G; Attarian, David E; Wellman, Samuel S; Bolognesi, Michael P

    2018-07-01

    Pseudotumor formation from metal-on-metal (MoM) hip implants is associated with implant revision. The relationship between pseudotumor type and patient outcomes is unknown. We retrospectively reviewed patients with a MoM total hip arthroplasty and metal artifact reduction sequence magnetic resonance imaging. Pseudotumors were graded using a validated classification system by a fellowship-trained radiologist. Patient demographics, metal ion levels, and implant survival were analyzed. Pseudotumors were present in 49 hips (53%). Thirty-two (65%) pseudotumors were cystic thin walled, 8 (16%) were cystic thick walled, and 9 (18%) were solid masses. Patients with pseudotumors had high offset stems (P = .030) but not higher metal ion levels. Patients with thick-walled cystic or solid masses were more likely to be symptomatic (P = .025) and were at increased risk for revision (P = .004) compared to patients with cystic lesions. Pseudotumor formation is present in 53% of patients with a MoM total hip arthroplasty, of which 40% were asymptomatic. Patients with thick-walled cystic and solid lesions were more likely to be symptomatic and undergo revision. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Preoperative anaemia is associated with increased allogeneic pack red cell transfusion in revision hip and knee joint arthroplasty: a retrospective analysis of 5387 patients over a 10-year period at a single high volume centre.

    PubMed

    Kasivisvanathan, R; Ramesh, V; Rao Baikady, R; Nadaraja, S

    2016-08-01

    To estimate the prevalence of preoperative World Health Organization (WHO) defined anaemia in patients presenting for revision hip and knee arthroplasty and its association with transfusion of allogeneic packed red blood cells (PRBC). Studies have mainly investigated the prevalence of preoperative anaemia in primary and not revision hip and knee joint arthroplasty. An analysis of a prospectively collected patient data for 5387 patients having revision hip or knee arthroplasty over a 10-year period at a single high volume centre was conducted. Logistic regression was used to assess whether the presence of WHO defined preoperative anaemia as well as other risk factors were associated with inpatient allogeneic PRBC transfusion. There were 5387 patients assessed of which 3021 (56·01%) patients had revision total hip replacements and 2366 (43·09%) had revision total knee arthroplasty. Of these patients 1956 (36·03%) had preoperative WHO defined anaemia. A total of 2034 (37·08%) patients received at least one unit of allogeneic PRBC during their primary hospital admission. In the final model preoperative WHO defined anaemia was independently associated with allogeneic PRBC transfusion in hip and knee revision surgery OR 4·042 (4·012-4·072 95% CI) CONCLUSIONS: Preoperative anaemia is common in patients presenting for revision hip and knee arthroplasty and independently associated with transfusion of allogeneic PRBC. © 2016 British Blood Transfusion Society.

  13. [Survey on the use and behaviour of metal-metal hip replacements in Spain].

    PubMed

    Calcerrada, N; Fernández-Vega, A; Valls-León, C; Garcia-Cimbrelo, E

    2016-01-01

    Following medical device alerts published in different countries of problems with metal-on-metal total hip replacements, the Spanish Agency of Medicines and Medical Devices (AEMPS) in collaboration with the Spanish Hip Society Surgery designed a national survey to gather information on the use and behaviour of these hip implants. The survey consisted of a questionnaire sent by e-mail to 283 clinical centre recipients of metal-on-metal hips to be filled in by surgeons with expertise in the field. A total of 257 questionnaires were completed. The response rate of the clinical centres was 36.7%. A total of 97.7% of the responses reported that clinical and radiological follow-ups are carried out, and 79.6% undertook metal ion analyses (chromium and cobalt). A large majority (83.6%) of the responders who had who used surface implants, and 70% of those with large-head implants reported peri-operative complications. The most common complication was pain (25% with surface implants and 30.8% with large-head implants). Currently 80.8% of those responding were considering abandoning implanting of these hip replacements. Despite the many limitations to this study, the survey has allowed us to obtain in a quick first view of the implant scenario of Metal on Metal hip implants in Spain, and to determine the type of patient implanted, the time of implantation, and the experience/expertise of the surgeons, and the type of follow-up carried out. Copyright © 2015 SECOT. Published by Elsevier Espana. All rights reserved.

  14. Mortality After Total Knee and Total Hip Arthroplasty in a Large Integrated Health Care System.

    PubMed

    Inacio, Maria C S; Dillon, Mark T; Miric, Alex; Navarro, Ronald A; Paxton, Elizabeth W

    2017-01-01

    The number of excess deaths associated with elective total joint arthroplasty in the US is not well understood. To evaluate one-year postoperative mortality among patients with elective primary and revision arthroplasty procedures of the hip and knee. A retrospective analysis was conducted of hip and knee arthroplasties performed in 2010. Procedure type, procedure volume, patient age and sex, and mortality were obtained from an institutional total joint replacement registry. An integrated health care system population was the sampling frame for the study subjects and was the reference group for the study. Standardized 1-year mortality ratios (SMRs) and 95% confidence intervals (CIs) were calculated. A total of 10,163 primary total knee arthroplasties (TKAs), 4963 primary total hip arthroplasties (THAs), 606 revision TKAs, and 496 revision THAs were evaluated. Patients undergoing primary THA (SMR = 0.6, 95% CI = 0.4-0.7) and TKA (SMR = 0.4, 95% CI = 0.3-0.5) had lower odds of mortality than expected. Patients with revision TKA had higher-than-expected mortality odds (SMR = 1.8, 95% CI = 1.1-2.5), whereas patients with revision THA (SMR = 0.9, 95% CI = 0.4-1.5) did not have higher-than-expected odds of mortality. Understanding excess mortality after joint surgery allows clinicians to evaluate current practices and to determine whether certain groups are at higher-than-expected mortality risk after surgery.

  15. Metal-on-Metal Total Hip Resurfacing Arthroplasty

    PubMed Central

    2006-01-01

    Executive Summary Objective The objective of this review was to assess the safety and effectiveness of metal on metal (MOM) hip resurfacing arthroplasty for young patients compared with that of total hip replacement (THR) in the same population. Clinical Need Total hip replacement has proved to be very effective for late middle-aged and elderly patients with severe degenerative diseases of the hips. As indications for THR began to include younger patients and those with a more active life style, the longevity of the implant became a concern. Evidence suggests that these patients experience relatively higher rates of early implant failure and the need for revision. The Swedish hip registry, for example, has demonstrated a survival rate in excess of 80% at 20 years for those aged over 65 years, whereas this figure was 33% by 16 years in those aged under 55 years. Hip resurfacing arthroplasty is a bone-conserving alternative to THR that restores normal joint biomechanics and load transfer. The technique has been used around the world for more than 10 years, specifically in the United Kingdom and other European countries. The Technology Metal-on-metal hip resurfacing arthroplasty is an alternative procedure to conventional THR in younger patients. Hip resurfacing arthroplasty is less invasive than THR and addresses the problem of preserving femoral bone stock at the initial operation. This means that future hip revisions are possible with THR if the initial MOM arthroplasty becomes less effective with time in these younger patients. The procedure involves the removal and replacement of the surface of the femoral head with a hollow metal hemisphere, which fits into a metal acetabular cup. Hip resurfacing arthroplasty is a technically more demanding procedure than is conventional THR. In hip resurfacing, the femoral head is retained, which makes it much more difficult to access the acetabular cup. However, hip resurfacing arthroplasty has several advantages over a conventional THR with a small (28 mm) ball. First, the large femoral head reduces the chance of dislocation, so that rates of dislocation are less than those with conventional THR. Second, the range of motion with hip resurfacing arthroplasty is higher than that achieved with conventional THR. A variety of MOM hip resurfacing implants are used in clinical practice. Six MOM hip resurfacing implants have been issued licences in Canada. Review Strategy A search of electronic bibliographies (OVID Medline, Medline In-Process and Other Non-Indexed Citations, Embase, Cochrane CENTRAL and DSR, INAHTA) was undertaken to identify evidence published from Jan 1, 1997 to October 27, 2005. The search was limited to English-language articles and human studies. The literature search yielded 245 citations. Of these, 11 met inclusion criteria (9 for effectiveness, 2 for safety). The result of the only reported randomized controlled trial on MOM hip resurfacing arthroplasty could not be included in this assessment, because it used a cemented acetabular component, whereas in the new generation of implants, a cementless acetabular component is used. After omitting this publication, only case series remained. Summary of Findings   Health Outcomes The Harris hip score and SF-12 are 2 measures commonly used to report health outcomes in MOM hip resurfacing arthroplasty studies. Other scales used are the Oxford hip score and the University of California Los Angeles hip score. The case series showed that the mean revision rate of MOM hip resurfacing arthroplasty is 1.5% and the incidence of femoral neck fracture is 0.67%. Across all studies, 2 cases of osteonecrosis were reported. Four studies reported improvement in Harris hip scores. However, only 1 study reported a statistically significant improvement. Three studies reported improvement in SF-12 scores, of which 2 reported a significant improvement. One study reported significant improvement in UCLA hip score. Two studies reported postoperative Oxford hip scores, but no preoperative values were reported. None of the reviewed studies reported procedure-related deaths. Four studies reported implant survival rates ranging from 94.4% to 99.7% for a follow-up period of 2.8 to 3.5 years. Three studies reported on the range of motion. One reported improvement in all motions including flexion, extension, abduction-adduction, and rotation, and another reported improvement in flexion. Yet another reported improvement in range of motion for flexion abduction-adduction and rotation arc. However, the author reported a decrease in the range of motion in the arc of flexion in patients with Brooker class III or IV heterotopic bone (all patients were men). Safety of Metal-on-Metal Hip Resurfacing Arthroplasty There is a concern about metal wear debris and its systemic distribution throughout the body. Detectable metal concentrations in the serum and urine of patients with metal hip implants have been described as early as the 1970s, and this issue is still controversial after 35 years. Several studies have reported high concentration of cobalt and chromium in serum and/or urine of the patients with metal hip implants. Potential toxicological effects of the elevated metal ions have heightened concerns about safety of MOM bearings. This is of particular concern in young and active patients in whom life expectancy after implantation is long. Since 1997, 15 studies, including 1 randomized clinical trial, have reported high levels of metal ions after THR with metal implants. Some of these studies have reported higher metal levels in patients with loose implants. Adverse Biological Effects of Cobalt and Chromium Because patients who receive a MOM hip arthroplasty are shown to be exposed to high concentrations of metallic ions, the Medical Advisory Secretariat searched the literature for reports of adverse biological effects of cobalt and chromium. Cobalt and chromium make up the major part of the metal articulations; therefore, they are a focus of concern. Risk of Cancer To date, only one study has examined the incidence of cancer after MOM and polyethylene on metal total hip arthroplasties. The results were compared to that of general population in Finland. The mean duration of follow-up for MOM arthroplasty was 15.7 years; for polyethylene arthroplasty, it was 12.5 years. The standardized incidence ratio for all cancers in the MOM group was 0.95 (95% CI, 0.79–1.13). In the polyethylene on metal group it was 0.76 (95% CI, 0.68–0.86). The combined standardized incidence ratio for lymphoma and leukemia in the patients who had MOM THR was 1.59 (95% CI, 0.82–2.77). It was 0.59 (95% CI, 0.29–1.05) for the patients who had polyethylene on metal THR. Patients with MOM THR had a significantly higher risk of leukemia. All patients who had leukemia were aged over than 60 years. Cobalt Cardiotoxicity   Epidemiological Studies of Myocardiopathy of Beer Drinkers An unusual type of myocardiopathy, characterized by pericardial effusion, elevated hemoglobin concentrations, and congestive heart failure, occurred as an epidemic affecting 48 habitual beer drinkers in Quebec City between 1965 and 1966. This epidemic was directly related the consumption of a popular beer containing cobalt sulfate. The epidemic appeared 1 month after cobalt sulfate was added to the specific brewery, and no further cases were seen a month after this specific chemical was no longer used in making this beer. A beer of the same name is made in Montreal, and the only difference at that time was that the Quebec brand of beer contained about 10 times more cobalt sulphate. Cobalt has been added to some Canadian beers since 1965 to improve the stability of the foam but it has been added in larger breweries only to draught beer. However, in small breweries, such as those in Quebec City, separate batches were not brewed for bottle and draught beer; therefore, cobalt was added to all of the beer processed in this brewery. In March 1966, a committee was appointed under the chairmanship of the Deputy Minister of Health for Quebec that included members of the department of forensic medicine of Quebec’s Ministry of Justice, epidemiologists, members of Food and Drug Directorate of Ottawa, toxicologists, biomedical researchers, pathologists, and members of provincial police. Epidemiological studies were carried out by the Provincial Ministry of Health and the Quebec City Health Department. The association between the development of myocardiopathy and the consumption of the particular brand of beer was proven. The mortality rate of this epidemic was 46.1% and those who survived were desperately ill, and recovered only after a struggle for their lives. Similar cases were seen in Omaha (Nebraska). The epidemic started after a cobalt additive was used in 1 of the beers marketed in Nebraska. Sixty-four patients with the clinical diagnosis of alcoholic myocardiopathy were seen during an 18-month period (1964–1965). Thirty of these patients died. The first patient became ill within 1 month after cobalt was added to the beer, and the last patient was seen within 1 month of withdrawal of cobalt. A similar epidemic occurred in Minneapolis, Minnesota. Between 1964 and 1967, 42 patients with acute heart failure were admitted to a hospital in Minneapolis, Minnesota. Twenty of these patients were drinking 6 to 30 bottles per day of a particular brand of beer exclusively. The other 14 patients also drank the same brand of beer, but not exclusively. The mortality rate from the acute illness was 18%, but late deaths accounted for a total mortality rate of 43%. Examination of the tissue from these patients revealed markedly abnormal changes in myofibrils (heart muscles), mitochondria, and sarcoplasmic reticulum. In Belgium, a similar epidemic was reported in 1966, in which, cobalt was used in some Belgian beers. There was a difference in mortality between the Canadian or American epidemic and this series. Only 1 of 24 patients died, 1.5 years after the diagnosis. In March 1965, at an international meeting in Brussels, a new heart disease in chronic beer drinkers was described. This disease consists of massive pericardial effusion, low cardiac output, raised venous pressure, and polycythemia in some cases. This syndrome was thought to be different from the 2 other forms of alcoholic heart disease (beriberi and a form characterized by myocardial fibrosis). The mystery of the above epidemics as stated by investigators is that the amount of cobalt added to the beer was below the therapeutic doses used for anemia. For example, 24 pints of Quebec brand of beer in Quebec would contain 8 mg of cobalt chloride, whereas an intake of 50 to 100 mg of cobalt as an antianemic agent has been well tolerated. Thus, greater cobalt intake alone does not explain the occurrence of myocardiopathy. It seems that there are individual differences in cobalt toxicity. Other features, like subclinical alcoholic heart disease, deficient diet, and electrolyte imbalance could have been precipitating factors that made these patients susceptible to cobalt’s toxic effects. In the Omaha epidemic, 60% of the patients had weight loss, anorexia, and occasional vomiting and diarrhea 2 to 6 months before the onset of cardiac symptoms. In the Quebec epidemic, patients lost their appetite 3 to 6 months before the diagnosis of myocardiopathy and developed nausea in the weeks before hospital admission. In the Belgium epidemic, anorexia was one of the most predominant symptoms at the time of diagnosis, and the quality and quantity of food intake was poor. Alcohol has been shown to increase the uptake of intracoronary injected cobalt by 47%. When cobalt enters the cells, calcium exits; this shifts the cobalt to calcium ratio. The increased uptake of cobalt in alcoholic patients may explain the high incidence of cardiomyopathies in beer drinkers’ epidemics. As all of the above suggest, it may be that prior chronic exposure to alcohol and/or a nutritionally deficient diet may have a marked synergistic effect with the cardiotoxicity of cobalt. Conclusions MOM hip resurfacing arthroplasty has been shown to be an effective arthroplasty procedure as tested in younger patients. However, evidence for effectiveness is based only on 7 case series with short duration of follow-up (2.8–3.5 years). There are no RCTs or other well-controlled studies that compare MOM hip resurfacing with THR. Revision rates reported in the MOM studies using implants currently licensed in Canada (hybrid systems, uncemented acetabular, and cemented femoral) range from 0.3% to 3.6% for a mean follow-up ranging from 2.8 to 3.5 years. Fracture of femoral neck is not very common; it occurs in 0.4% to 2.2% of cases (as observed in a short follow-up period). All the studies that measured health outcomes have reported improvement in Harris Hip and SF-12 scores; 1 study reported significant reduction in pain and improvement in function, and 2 studies reported significant improvement in SF-12 scores. One study reported significant improvement in UCLA Hip scores. Concerns remain on the potential adverse effects of metal ions. Longer-term follow-up data will help to resolve the inconsistency of findings on adverse effects, including toxicity and carcinogenicity. Ontario-Based Economic Analysis The device cost for MOM ranges from $4,300 to $6,000 (Cdn). Traditional hip replacement devices cost about $2,000 (Cdn). Using Ontario Case Costing Initiative data, the total estimated costs for hip resurfacing surgery including physician fees, device fees, follow-up consultation, and postsurgery rehabilitation is about $15,000 (Cdn). Figure 1: Cost of Total Hip Replacement Surgery in Ontario Hip Resurfacing Surgery (Based on 2005/06 inflationary-adjusted rates) Weighted Average (Academic Community! al-inclusive hospitalization cost of surgery $ 6.767.18 Device Cost $ 5,400.00 Additional Medication $ 330.75 Follow-up Consultation $ 190.30 Rehab (per outpatient CCAC case) $ 1,500.00 OH P costs (average) $ 1,068.60 Total Estimated Cost $ 15,256.83 MOM hip arthroplasty is generally recommended for patients aged under 55 years because its bone-conserving advantage enables patients to “buy time” and hence helps THRs to last over the lifetime of the patient. In 2004/2005, 15.9% of patients who received THRs were aged 55 years and younger. It is estimated that there are from 600 to 1,000 annual MOM hip arthroplasty surgeries in Canada with an estimated 100 to 150 surgeries in Ontario. Given the increased public awareness of this device, it is forecasted that demand for MOM hip arthroplasty will steadily increase with a conservative estimate of demand rising to 1,400 cases by 2010 (Figure 10). The net budget impact over a 5-year period could be $500,000 to $4.7 million, mainly because of the increasing cost of the device. Figure 2: Projected Number of Metal-on-Metal Hip Arthroplasty Surgeries in Ontario: to 2010 PMID:23074495

  16. Metal-on-Metal Hip Retrieval Analysis: A Case Report

    PubMed Central

    Pace, Thomas B.; Rusaw, Kara A.; Minette, Lawrence J.; Shirley, Brayton R.; Snider, Rebecca G.; DesJardins, John D.

    2013-01-01

    This is a case report involving a single case with severe bone and soft tissue destruction in a young male patient with a 10-year-metal on-metal total hip arthroplasty. Following complete aseptic erosion of the affected hip greater trochanter and abductor muscles, the hip was revised for recurrent instability. Histological examination of the patient's periprosthetic tissues, serological studies, and review of recent medical reports of similar cases were used to support an explanation of the destructive process and better contribute to our understanding of human reaction to metal debris in some patients following metal-on-metal hip arthroplasty. PMID:23840999

  17. Conversion of hip fusion to total hip arthroplasty: clinical, radiological outcomes and complications in 40 hips.

    PubMed

    Celiktas, Mustafa; Kose, Ozkan; Turan, Adil; Guler, Ferhat; Ors, Cagri; Togrul, Emre

    2017-01-01

    The purpose of this retrospective study is to report the clinical and radiological outcome of total hip arthroplasty in patients with previous hip arthrodesis. We retrospectively reviewed 28 (40 hips) prospectively followed patients in whom ankylosed hips were converted to total hip arthroplasty (THA) between 2010 and 2014 in our institution. The average age at the time of the conversion operation was 40.8 ± 9.8 years (range 24-62). The ankylosis had lasted 20.4 ± 13.0 years (range 3-56) before conversion surgery. The etiology of the ankylosis was septic arthritis in 10 (25%), post-traumatic hip osteoarthritis in 8 (20%), developmental hip dysplasia in 6 (15%), rheumatoid arthritis in 6 (15%), primary osteoarthritis in 5 (12.5%) and ankylosing spondylitis in 5 (12.5%) hips. The indications for arthroplasty were intractable low back pain in 14 (50%), hip pain in 24 (85.7%), and ipsilateral knee pain in 19 (67.8%) patients. Harris Hip Score (HHS) was used to rate the clinical results before and after the surgery. Radiographic evaluations included component malposition and loosening. All complications during the study period were recorded. The mean follow-up period was 39.9 ± 10.6 months (range 24-60). The mean preoperative HHS was 33.3 ± 8.6 (range 18-50) and the mean HHS at the final follow-up was 74.9 ± 8.6 (range 52-97). There was a statistically significant increase in HHS (p = 0.0001). HHS was excellent in 1, good in 6, fair in 14 and poor in 7 patients. Increase in HHS was lower than 20 points in one patient (18 points), and one patient required two-staged exchange procedure due to deep infection. Thus, according to our success criteria (increase in HHS more than 20 points, radiographically stable implant, and no further surgical reconstruction), 92.8% (26/28) of patients had benefit from the surgery. Trendelenburg sign was positive in 12 hips. There was limb length inequality in 11 patients (mean 0.5 cm, range 1-3 cm). No patients had heterotopic ossification, sciatic nerve palsy or dislocation. There were five intra-operative fractures of the greater trochanter that were treated with cable wiring. One patient had trochanteric avulsion injury and was treated with trochanteric grip and cables. One patient (2.5%) had deep infection one year after the conversion THA and was treated with two-staged exchange procedure. Conversion hip arthroplasty is an effective treatment method which provides functional recovery and patient satisfaction. However, a proper surgical technique and planning is necessary to minimize the complications.

  18. Female Sex Is a Risk Factor for Failure of Hip Arthroscopy Performed for Acetabular Retroversion

    PubMed Central

    Poehling-Monaghan, Kirsten L.; Krych, Aaron J.; Levy, Bruce A.; Trousdale, Robert T.; Sierra, Rafael J.

    2017-01-01

    Background: The success of hip surgery in treating acetabular retroversion depends on the severity of the structural deformity and on selecting the correct patient for open or arthroscopic procedures. Purpose: To compare a group of patients with retroverted hips treated successfully with hip arthroscopy with a group of patients with retroverted hips that failed arthroscopic surgery, with special emphasis on (1) patient characteristics, (2) perioperative radiographic parameters, (3) intraoperative findings and concomitant procedures, and (4) patient sex. Study Design: Case-control study; Level of evidence, 3. Methods: We retrospectively reviewed the charts of 47 adult patients (47 hips) with acetabular retroversion who had undergone hip arthroscopy. Retroversion was based on the presence of an ischial spine sign in addition to either a crossover or posterior wall sign on a well-positioned anteroposterior pelvic radiograph. A total of 24 hips (50%) (16 females, 8 males; mean patient age, 31 years) had failed arthroscopy, defined as modified Harris Hip Score (mHHS) <80 or need for subsequent procedure. Twenty-three hips (8 females, 15 males; mean patient age, 29 years) were considered successful, defined as having no subsequent procedures and an mHHS >80 at the time of most recent follow-up. Perioperative variables, radiographic characteristics, and intraoperative findings were compared between the groups, in addition to a subgroup analysis based on sex. Results: The mean follow-up for successful hips was 30 months (SD, 11 months), with a mean mHHS of 95. In the failure group, 6 patients required subsequent procedures (4 anteverting periacetabular osteotomies and 2 total hip arthroplasties). The mean overall time to failure was 21 months, and the mean time to a second procedure was 24 months (total hip arthroplasty, 29.5 months; periacetabular osteotomy, 21.2 months); 18 hips failed on the basis of a low mHHS (mean, 65; range, 27-79) at last follow-up. Factors significantly different between the success and failure groups included patient sex, with males being more likely than females to have a successful outcome (P < .02), as well as undergoing femoral osteoplasty (P < .02). Intraoperative variables that were associated with worse outcome included isolated labral debridement (P < .002). In a subgroup analysis, males were more likely than their female counterparts to have a successful outcome with both isolated cam and combined cam-pincer resection (P < .05). Level of crossover correction on postoperative radiographs had no correlation with outcome. Conclusion: Acetabular retroversion remains a challenging pathoanatomy to treat arthroscopically. If hip arthroscopy is to be considered in select cases, we recommend labral preservation when possible. Male patients with correction of cam deformities did well, while females with significant retroversion appeared to be at greater risk for failure of arthroscopic treatment. PMID:29164164

  19. The influence of optimism on functionality after total hip replacement surgery.

    PubMed

    Balck, Friedrich; Lippmann, Maike; Jeszenszky, Csilla; Günther, Klaus-Peter; Kirschner, Stephan

    2016-08-01

    Among other factors, optimism has been shown to significantly influence the course of some diseases (cancer, HIV, coronary heart disease). This study investigated whether optimism of a patient before a total hip replacement can predict the functionality of the lower limbs 3 and 6 months after surgery. A total of 325 patients took part in the study (age: 58.7 years; w: 55%). The functionality was measured with the Western Ontario and McMaster Universities arthrosis index, and optimism with the Life Orientation Test. To analyse the influences of age, gender and optimism, general linear models were calculated. In optimistic patients, functionality improved significantly over time. The study showed a clear influence of dispositional optimism on the recovery after total hip replacement in the first 3 months after surgery. © The Author(s) 2015.

  20. Early migration characteristics of a 180° porous-coated cup with 1-mm press fit.

    PubMed

    Stihsen, Christoph; Rath, Christopher; Radl, Roman; Saalabian, Ali A; Materna, Wilfried; Rehak, Peter; Windhager, Reinhard

    2013-05-01

    Evaluation of early cup movement is an important diagnostic tool to predict the likelihood of long-term implant loosening and clinical failure. The investigated cementless cup is clinically proven over 10 years, but there is a paucity of information that accurately describes the migration characteristics of this component. We retrospectively analysed the clinical outcome and migration behaviour of 60 Pinnacle 100 shells after an average 3.8-year follow-up (range 2.1-5.4 years). For migration measurement, EBRA (Einzel-Bild-Röntgen-Analyse) digital software was applied. Clinical assessment was performed using the HHS, the UCLA score and the SF-36 health survey. The clinical outcome showed excellent results with a mean HHS of 95.4 (SD 7.1) and mean UCLA of 6.9 (SD 1.3). All implants were radiologically stable within the observation period and none of the cups was at risk for aseptical loosening. EBRA analysis revealed a mean total migration of 1.4 mm (SD 0.9) (95 % CI 1.1-1.6) at 3 years. Eight cups migrated more than 1 mm within the first three postoperative months, thereafter the migration curves flattened down. Surgeons may expect to find a variable amount of early migration when using the Pinnacle cup. To our knowledge, these are the first results, which show an early "impaction" of a cementless cup, followed by subsequent osseointegration. We believe that an appropriate long-term outcome of the investigated cup is ensured. The data of the present investigation will provide clinicians with useful baseline information with which to compare new cup designs.

  1. [Modern tribology in total hip arthroplasty: pros and cons].

    PubMed

    Gómez-García, F

    2014-01-01

    The wear products and adverse reactions that occur on bearing surfaces represent one of the greatest challenges in prosthetic replacements, as the latter experience increasing demands due to the large number of young and older adult patients that have a long life expectancy and remarkable activity. The purpose of this review is to analyze the pros and cons of the new advances in the bearing components of the articular surfaces of current total hip arthroplasties. We also discuss the strategies used historically, their problems, results and the surgeon's role in prescribing the tribologic couple that best fits each patient's needs. We conclude with practical recommendations for the prescription and management of the latest articular couples for total hip arthroplasty.

  2. Patient Satisfaction Reporting After Total Hip Arthroplasty: A Systematic Review.

    PubMed

    Kahlenberg, Cynthia A; Nwachukwu, Benedict U; Schairer, William W; Steinhaus, Michael E; Cross, Michael B

    2017-05-01

    This review evaluated the quality of patient satisfaction reporting after total hip arthroplasty. The initial search of the MEDLINE database yielded 755 studies. Twenty-four met the inclusion criteria. Most studies provided level III or IV evidence (n=15, 62.5%). The most common method used to assess satisfaction was the 10-point visual analog scale (7 studies, 29.2%), followed by an ordinal satisfaction scale (6 studies, 25.0%). The quality of evidence was poor, and the methods used to assess satisfaction were not standardized. Further research is needed to define the factors that affect patient satisfaction after total hip arthroplasty and how satisfaction is best measured. [Orthopedics. 2017; 40(3):e400-e404.]. Copyright 2017, SLACK Incorporated.

  3. Dissociation of modular total hip arthroplasty at the neck-stem interface without dislocation.

    PubMed

    Kouzelis, A; Georgiou, C S; Megas, P

    2012-12-01

    Modular femoral and acetabular components are now widely used, but only a few complications related to the modularity itself have been reported. We describe a case of dissociation of the modular total hip arthroplasty (THA) at the femoral neck-stem interface during walking. The possible causes of this dissociation are discussed. Successful treatment was provided with surgical revision and replacement of the modular neck components. Surgeons who use modular components in hip arthroplasties should be aware of possible early complications in which the modularity of the prostheses is the major factor of failure.

  4. Determining Health-Related Quality-of-Life Outcomes Using the SF-6D Following Total Hip Arthroplasty.

    PubMed

    Elmallah, Randa K; Chughtai, Morad; Adib, Farshad; Bozic, Kevin J; Kurtz, Steven M; Mont, Michael A

    2017-03-15

    Following total hip arthroplasty, patients' perception of their postoperative improvement and health plays a large role in satisfaction with and success of the surgical procedure. The Short Form-6D (SF-6D) is a health-related quality-of-life measure that assigns numerical value to the perception of patients' own health. The purpose was to determine SF-6D values of patients after total hip arthroplasty, to determine whether score changes were clinically relevant, and to compare these with postoperative functional improvements. We evaluated 188 patients who underwent primary total hip arthroplasty at 7 institutions and who had a mean age of 69 years (range, 47 to 88 years) and a mean body mass index of 28.8 kg/m (range, 19.8 to 38.9 kg/m). The SF-6D values were obtained from patients' SF-36 scores, and clinical relevance of value changes was determined using effect size. Using previous research, effect sizes were considered small between 0.2 and 0.5, moderate between 0.6 to 0.8, and large at >0.8. Clinical correlation was assessed using the Lower-Extremity Activity Scale and Harris hip scores. Patients were assessed preoperatively and postoperatively at 6 months and 1, 2, 3, and 5 years. The SF-6D scores improved from preoperatively and achieved significance (p < 0.05) at all points. The effect size demonstrated good clinical relevance up to the latest follow-up: 1.27 at 6 months, 1.30 at 1 year, 1.07 at 2 years, 1.08 at 3 years, and 1.05 at 5 years. The Lower-Extremity Activity Scale improved at all follow-up points from preoperatively to 1.8 at 6 months, 2.0 at 1 year, 1.8 at 2 years, 1.5 at 3 years, and 1.6 points at 5 years. The Harris hip score improved to 38 points at 6 months, 40 points at 1 year, 38 points at 2 years, 39 points at 3 years, and 41 points at 5 years postoperatively. The improvements in the Lower-Extremity Activity Scale and the Harris hip score significantly positively correlated (p < 0.01) with the SF-6D scores at all time points. SF-6D scores after total hip arthroplasty correlate with functional outcomes and have clinical relevance, as demonstrated by their effect size. Incorporating this straightforward and easy-to-use measurement tool when evaluating patients following total hip arthroplasty will facilitate future cost-utility analyses. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  5. [Poldi-Čech cemented femoral stem in total hip arthroplasty after 25 years].

    PubMed

    Rozkydal, Z; Janíček, P

    2010-08-01

    The aim of the study was to evaluate the results of Poldi-Čech femoral stem implantation in primary total hip arthroplasty after 25 years. A group of 65 patients (90 hips) with Poldi-Čech total hip arthroplasty carried out between 1974 and 1984 was evaluated at the end of 2009. The mean follow-up of all patients was 28 years (25 to 35). There were seven men and 58 women. The mean age at the time of implantation was 43 years (26 to 60) and at the latest follow-up it was 72 years. In all patients the cemented UHMW PE acetabular component (RCH 1000) was used together with AKV Ultra 2 Poldi steel femoral stems (1st, 2nd and 3rd generations). The stem was a monoblock with a 32-mm head. The evaluation of the results was based on the Harris hip score and X ray with an A-P view of the pelvis and the affected hip. Statistical analysis was made using the life-table method. At the latest follow up the mean Harris score was 69.7 points (40 to 88). There were 69 hips with an original Poldi-Čech femoral component still in situ, 64 of them were stable and five with radiological evidence of aseptic loosening. Five patients had undergone Girdlestone resection arthroplasty for septic loosening. Thirteen patients (16 hips) had femoral stem revision. The cumulative proportion of clinical survivorship of the Poldi-Čech femoral stem, with revision for any reason as the endpoint, .was 0.93 at 6 years, 0.84 at 12 years, and 0.77 at 18, 24 and 30 years after the index surgery. Radiographic findings revealed 64 hips with stable stems, five hips with ;aseptic loosening (probable, 0 possible, 2, definite, 3). Six- teen hips were after revision surgery for aseptic loosening of the stem and five hips were after Girdlestone resection arthroplasty for septic failure. The cumulative proportion of radiological survivorship of the Poldi-Čech femoral stem with any reason as the endpoint was 0.92 at 6 years, 0.78 at 12 years, 0.72 at 18 years, 0.69 at 24 years and 0.69 at 30 years. The Poldi-Čech stem with its anatomical shape and a highly polished surface meets the principles of successful composite beam stems. Its disadvantage is a valgus neck- shaft angle of 140° giving lower femoral offset and the risk of development of valgus deformity of the ipsilateral knee. In most cases osteolysis, radiolucent lines and bone rarefaction of the femur resulted from polyethylene wear of the acetabular component. This study demonstrates a long-term survivorship of the Poldi-Čech femoral component in patients undergoing total hip arthroplasty 25 to 35 years ago.

  6. Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021.

    PubMed

    Kurtz, Steven M; Ong, Kevin L; Lau, Edmund; Bozic, Kevin J

    2014-04-16

    Few studies have explored the role of the National Health Expenditure and macroeconomics on the utilization of total joint replacement. The economic downturn has raised questions about the sustainability of growth for total joint replacement in the future. Previous projections of total joint replacement demand in the United States were based on data up to 2003 using a statistical methodology that neglected macroeconomic factors, such as the National Health Expenditure. Data from the Nationwide Inpatient Sample (1993 to 2010) were used with United States Census and National Health Expenditure data to quantify historical trends in total joint replacement rates, including the two economic downturns in the 2000s. Primary and revision hip and knee arthroplasty were identified using codes from the International Classification of Diseases, Ninth Revision, Clinical Modification. Projections in total joint replacement were estimated using a regression model incorporating the growth in population and rate of arthroplasties from 1993 to 2010 as a function of age, sex, race, and census region using the National Health Expenditure as the independent variable. The regression model was used in conjunction with government projections of National Health Expenditure from 2011 to 2021 to estimate future arthroplasty rates in subpopulations of the United States and to derive national estimates. The growth trend for the incidence of joint arthroplasty, for the overall United States population as well as for the United States workforce, was insensitive to economic downturns. From 2009 to 2010, the total number of procedures increased by 6.0% for primary total hip arthroplasty, 6.1% for primary total knee arthroplasty, 10.8% for revision total hip arthroplasty, and 13.5% for revision total knee arthroplasty. The National Health Expenditure model projections for primary hip replacement in 2020 were higher than a previously projected model, whereas the current model estimates for total knee arthroplasty were lower. Economic downturns in the 2000s did not substantially influence the national growth trends for hip and knee arthroplasty in the United States. These latest updated projections provide a basis for surgeons, hospitals, payers, and policy makers to plan for the future demand for total joint replacement surgery.

  7. Does the addition of hip strengthening exercises improve outcomes following total knee arthroplasty? A study protocol for a randomized trial.

    PubMed

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-06-13

    Total knee arthroplasty (TKA) is effective in reducing pain and improving function for end-stage knee osteoarthritis. However, muscle weakness and functional limitations persist despite assistance from post-operative rehabilitation programs that traditionally focus on quadriceps strengthening and range of movement exercises. Hip abductor muscle weakness is evident in knee osteoarthritis and hip muscle strengthening reduces knee pain in this group. Following TKA, people with weak hip abductor strength perform more poorly on measures of physical function. However, very little is known of the effectiveness of including hip abductor strengthening exercises in post-operative rehabilitation. The aim of this trial is to compare the effects of targeted hip abductor strengthening to those of traditional care in a TKA rehabilitation program on muscle strength, patient reported outcomes and functional performance measures. This protocol describes a single-blinded randomized controlled trial, where 104 participants referred for inpatient rehabilitation following TKA will be recruited. Participants will be randomized using computer-generated numbers to one of two groups: usual care or usual care with additional hip strengthening exercises. Participants will attend physiotherapy daily during their inpatient length of stay, and will then attend between six and eight physiotherapy sessions as an outpatient. Primary outcomes are isometric hip abductor strength and the Knee Injury and Osteoarthritis Outcome Score (KOOS). Secondary outcomes are stair climb test, 6 min walk test, timed up and go, 40 m fast-paced walk test, 30 second chair stand test, isometric quadriceps strength, Lower Extremity Functional Scale (LEFS) and SF-12. Outcome measures will be recorded at baseline (admission to inpatient rehabilitation), and then 3 weeks, 6 weeks and 6 months post admission to rehabilitation. The findings of this study will determine whether the addition of targeted hip strengthening to usual care rehabilitation improves physical performance and patient reported outcomes following TKA when compared to usual care rehabilitation. This will then determine whether targeted hip strengthening exercises should be included in traditional rehabilitation programs to improve the outcomes following total knee arthroplasty. The trial protocol was registered with the Australian Clinical Trial Registry ( ACTRN12615000863538 ) on 18 August 2015.

  8. Surgical dislocation of the hip and the management of femoroacetabular impingement: results of the Christchurch experience.

    PubMed

    Kempthorne, Joshua T; Armour, Paul C; Rietveld, John A; Hooper, Gary J

    2011-06-01

    Surgical dislocation of the hip has been developed to deal with the problems causing femoroacetabular impingement (FAI). This is a relatively recent procedure that was historically reserved for larger areas specializing in hip surgery. We hypothesized that surgical dislocation can be used for symptomatic FAI in a typical Australasian tertiary orthopaedic centre with acceptable results. This prospective study reviews the results of 53 surgical dislocations in this setting, looking particularly at functional outcomes and early complications. There were significant improvements in the Western Ontario and McMaster University Osteoarthritis Index score at 1, 2, 3 and 4 years post-operatively. Western Ontario and McMaster University Osteoarthritis Index scores increased by 23, 28, 34 and 35 points, respectively (P 0.0039). There was no significant improvement in hip range of motion. There were two (4%) early failures with conversion to total hip arthroplasty, and no cases of post-operative avascular necrosis of the femoral head. We believe that as the diagnosis of FAI and conservative nonarthroplasty surgery of the hip gains wider acceptance, it will become a procedure that should be offered to all appropriate patients in an attempt to delay or limit total hip arthroplasty in this young age group.

  9. Lessons learned from study of congenital hip disease in adults.

    PubMed

    Hartofilakidis, George; Lampropoulou-Adamidou, Kalliopi

    2016-12-18

    Orthopaedic surgeons specialising in adult hip reconstruction surgery often face the problem of osteoarthritis secondary to congenital hip disease (CHD). To achieve better communication among physicians, better treatment planning and evaluation of the results of various treatment options, an agreed terminology is needed to describe the entire pathology. Furthermore, a generally accepted classification of the deformities is necessary. Herein, the authors propose the use of the term "congenital hip disease" and its classification as dysplasia, low dislocation and high dislocation. Knowledge of the CHD natural history facilitates comprehension of the potential development and progression of the disease, which differs among the aforementioned types. This can lead to better understanding of the anatomical abnormalities found in the different CHD types and thus facilitate preoperative planning and choice of the most appropriate management for adult patients. The basic principles for improved results of total hip replacement in patients with CHD, especially those with low and high dislocation, are: Wide exposure, restoration of the normal centre of rotation and the use of special techniques and implants for the reconstruction of the acetabulum and femur. Application of these principles during total hip replacement in young female patients born with severe deformities of the hip joint has led to radical improvement of their quality of life.

  10. Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

    PubMed

    Kwok, Iris H Y; Pallett, Scott J C; Massa, Edward; Cundall-Curry, Duncan; Loeffler, Mark D

    2016-03-01

    Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Predictors of perioperative blood loss in total joint arthroplasty.

    PubMed

    Park, Jai Hyung; Rasouli, Mohammad R; Mortazavi, S M Javad; Tokarski, Anthony T; Maltenfort, Mitchell G; Parvizi, Javad

    2013-10-02

    UPDATE The print version of this article has errors that have been corrected in the online version of this article. In the Materials and Methods section, the sentence that reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 mg/dL or a hematocrit level of at least 33%." in the print version now reads as "During the study period, our institution offered preoperative autologous blood donation to all patients who were scheduling for total joint arthroplasty with a hemoglobin level of no less than 11 g/dL or a hematocrit level of at least 33%." in the online version. In Table III, the footnote that reads as "The values are given as the estimate and the standard error in milligrams per deciliter." in the print version now reads as "The values are given as the estimate and the standard error in grams per deciliter." in the online version. Despite advances in surgical and anesthetic techniques, lower-extremity total joint arthroplasty is associated with considerable perioperative blood loss. As predictors of perioperative blood loss and allogenic blood transfusion have not yet been well defined, the purpose of this study was to identify clinical predictors for perioperative blood loss and allogenic blood transfusion in patients undergoing total joint arthroplasty. From 2000 to 2008, all patients undergoing unilateral primary total hip or knee arthroplasty who met the inclusion criteria were enrolled in the study. Perioperative blood loss was calculated with use of a previously validated formula. The predictors of perioperative blood loss and allogenic blood transfusion were identified in a multivariate analysis. Eleven thousand three hundred and seventy-three patients who underwent total joint arthroplasty, including 4769 patients who underwent total knee arthroplasty and 6604 patients who underwent total hip arthroplasty, were evaluated. Multivariate analysis indicated that an increase in blood loss was associated with being male (263.59 mL in male patients who had undergone total hip arthroplasty and 233.60 mL in male patients who had undergone total knee arthroplasty), a Charlson Comorbidity Index of >3 (293.99 mL in patients who had undergone total hip arthroplasty and 167.96 mL in patients who had undergone total knee arthroplasty), and preoperative autologous blood donation (593.51 mL in patients who had undergone total hip arthroplasty and 592.30 mL in patients who had undergone total knee arthroplasty). In patients who underwent total hip arthroplasty, regional anesthesia compared with general anesthesia reduced the amount of blood loss. The risk of allogenic blood transfusion increased with the amount of blood loss in the patients who underwent total hip arthroplasty (odds ratio, 1.43 [95% confidence interval, 1.40 to 1.46]) and the patients who underwent total knee arthroplasty (odds ratio, 1.47 [95% confidence interval, 1.42 to 1.51]), but the risk of blood transfusion increased with the Charlson Comorbidity Index only in patients who underwent total knee arthroplasty (odds ratio, 3.2 [95% confidence interval, 1.99 to 5.15]). The risk of allogenic blood transfusion decreased with preoperative autologous blood donation in patients who underwent total hip arthroplasty (odds ratio, 0.01 [95% confidence interval, 0.01 to 0.02]) and patients who underwent total knee arthroplasty (odds ratio, 0.02 [95% confidence interval, 0.01 to 0.03]). This study identified some clinical predictors for blood loss in patients undergoing total joint arthroplasty that we believe can be used for implementing more effective blood conservation strategies. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  12. Issues relating to long-term follow-up in hip arthroplasty surgery: a review of 598 cases at 7 years comparing 2 prostheses using revision rates, survival analysis, and patient-based measures.

    PubMed

    Dawson, J; Jameson-Shortall, E; Emerton, M; Flynn, J; Smith, P; Gundle, R; Murray, D

    2000-09-01

    We reviewed 598 cemented Charnley and Hi-nek total hip arthroplasties at 7 years. Data were obtained from general practitioners, hospital medical notes, microfilm, and patient questionnaires. Outcome measures were revision rates, survival analysis, 12-item Oxford Hip Score, and satisfaction ratings. There were 471 Charnley (79%) and 127 Hi-nek (21%) total hip arthroplasties; 139 deaths (23%) occurred, and 5 (<1%) were lost to follow-up. Characteristics of the Charnley and Hi-nek patient groups were similar, with more information missing for Charnley cases. Revision rates were Charnley, 37 (8%), and Hi-nek, 6 (5%) (not significant). Survival analysis revealed no difference between the 2 groups (P = .23). The patients' median Oxford Hip Score was low/good (19), slightly worse for the Hi-nek group (not significant). Taking all evidence together, neither implant was outperforming the other at 7 years.

  13. Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

    PubMed

    Fujishiro, Takaaki; Hayashi, Shinya; Kanzaki, Noriyuki; Hashimoto, Shingo; Shibanuma, Nao; Kurosaka, Masahiro

    2014-06-01

    The use of screws can enhance immediate cup fixation, but the influence of screw insertion on cup position has not previously been measured. The purpose of this study was to quantitatively evaluate the effect of intra-operative screw fixation on acetabular component alignment that has been inserted with the use of a navigation system. We used a navigation system to measure cup alignment at the time of press-fit and after screw fixation in 144 hips undergoing total hip arthroplasty. We also compared those findings with factors measured from postoperative radiographs. The mean intra-operative change of cup position was 1.78° for inclination and 1.81° for anteversion. The intra-operative change of anteversion correlated with the number of screws. The intra-operative change of inclination also correlated with medial hip centre. The insertion of screws can induce changes in cup alignment, especially when multiple screws are used or if a more medial hip centre is required for rigid acetabular fixation.

  14. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry.

    PubMed

    Lenguerrand, E; Whitehouse, M R; Beswick, A D; Jones, S A; Porter, M L; Blom, A W

    2017-06-01

    We used the National Joint Registry for England, Wales, Northern Ireland and the Isle of Man (NJR) to investigate the risk of revision due to prosthetic joint infection (PJI) for patients undergoing primary and revision hip arthroplasty, the changes in risk over time, and the overall burden created by PJI. We analysed revision total hip arthroplasties (THAs) performed due to a diagnosis of PJI and the linked index procedures recorded in the NJR between 2003 and 2014. The cohort analysed consisted of 623 253 index primary hip arthroplasties, 63 222 index revision hip arthroplasties and 7585 revision THAs performed due to a diagnosis of PJI. The prevalence, cumulative incidence functions and the burden of PJI (total procedures) were calculated. Overall linear trends were investigated with log-linear regression. We demonstrated a prevalence of revision THA due to prosthetic joint infection of 0.4/100 procedures following primary and 1.6/100 procedures following revision hip arthroplasty. The prevalence of revision due to PJI in the three months following primary hip arthroplasty has risen 2.3-fold (95% confidence interval (CI) 1.3 to 4.1) between 2005 and 2013, and 3.0-fold (95% CI 1.1 to 8.5) following revision hip arthroplasty. Over 1000 procedures are performed annually as a consequence of hip PJI, an increase of 2.6-fold between 2005 and 2013. Although the risk of revision due to PJI following hip arthroplasty is low, it is rising and, coupled with the established and further predicted increased incidence of both primary and revision hip arthroplasty, this represents a growing and substantial treatment burden. Cite this article : E. Lenguerrand, M. R. Whitehouse, A. D. Beswick, S. A. Jones, M. L. Porter, A. W. Blom. Revision for prosthetic joint infection following hip arthroplasty: Evidence from the National Joint Registry. Bone Joint Res 2017;6:391-398. DOI: 10.1302/2046-3758.66.BJR-2017-0003.R1. © 2017 Lenguerrand et al.

  15. Post-Discharge Care Duration, Charges, and Outcomes Among Medicare Patients After Primary Total Hip and Knee Arthroplasty.

    PubMed

    Ponnusamy, Karthikeyan E; Naseer, Zan; El Dafrawy, Mostafa H; Okafor, Louis; Alexander, Clayton; Sterling, Robert S; Khanuja, Harpal S; Skolasky, Richard L

    2017-06-07

    In April 2016, the U.S. Centers for Medicare & Medicaid Services initiated mandatory 90-day bundled payments for total hip and knee arthroplasty for much of the country. Our goal was to determine duration of care, 90-day charges, and readmission rates by discharge disposition and U.S. region after hip or knee arthroplasty. Using the 2008 Medicare Provider Analysis and Review database 100% sample, we identified patients who had undergone elective primary total hip or knee arthroplasty. We collected data on patient age, sex, comorbidities, U.S. Census region, discharge disposition, duration of care, 90-day charges, and readmission. Multivariate regression was used to assess factors associated with readmission (logistic) and charges (linear). Significance was set at p < 0.01. Patients undergoing 138,842 total hip arthroplasties were discharged to home (18%), home health care (34%), extended-care facilities (35%), and inpatient rehabilitation (13%); patients undergoing 329,233 total knee arthroplasties were discharged to home (21%), home health care (38%), extended-care facilities (31%), and inpatient rehabilitation (10%). Patients in the Northeast were more likely to be discharged to extended-care facilities or inpatient rehabilitation than patients in other regions. Patients in the West had the highest 90-day charges. Approximately 70% of patients were discharged home from extended-care facilities, whereas after inpatient rehabilitation, >50% of patients received home health care. Among those discharged to home, 90-day readmission rates were highest in the South (9.6%) for patients undergoing total hip arthroplasty and in the Midwest (8.7%) and the South (8.5%) for patients undergoing total knee arthroplasty. Having ≥4 comorbidities, followed by discharge to inpatient rehabilitation or an extended-care facility, had the strongest associations with readmission, whereas the region of the West and the discharge disposition to inpatient rehabilitation had the strongest association with higher charges. Among Medicare patients, discharge disposition and number of comorbidities were most strongly associated with readmission. Inpatient rehabilitation and the West region had the strongest associations with higher charges. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. Use of Hip Arthroscopy and Risk of Conversion to Total Hip Arthroplasty: A Population-Based Analysis.

    PubMed

    Schairer, William W; Nwachukwu, Benedict U; McCormick, Frank; Lyman, Stephen; Mayman, David

    2016-04-01

    To use population-level data to (1) evaluate the conversion rate of total hip arthroplasty (THA) within 2 years of hip arthroscopy and (2) assess the influence of age, arthritis, and obesity on the rate of conversion to THA. We used the State Ambulatory Surgery Databases and State Inpatient Databases for California and Florida from 2005 through 2012, which contain 100% of patient visits. Hip arthroscopy patients were tracked for subsequent primary THA within 2 years. Out-of-state patients and patients with less than 2 years follow-up were excluded. Multivariate analysis identified risks for subsequent hip arthroplasty after arthroscopy. We identified 7,351 patients who underwent hip arthroscopy with 2 years follow-up. The mean age was 43.9 ± 13.7 years, and 58.8% were female patients. Overall, 11.7% of patients underwent THA conversion within 2 years. The conversion rate was lowest in patients aged younger than 40 years (3.0%) and highest in the 60- to 69-year-old group (35.0%) (P < .001). We found an increased risk of THA conversion in older patients and in patients with osteoarthritis or obesity at the time of hip arthroscopy. Patients treated at high-volume hip arthroscopy centers had a lower THA conversion rate than those treated at low-volume centers (15.1% v 9.7%, P < .001). Hip arthroscopy is performed in patients of various ages, including middle-aged and elderly patients. Older patients have a higher rate of conversion to THA, as do patients with osteoarthritis or obesity. Level III, retrospective comparative study. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Screws are not needed when secure interference fit of uncemented acetabular components is adequate: a 5- to 15-year follow-up with clinical and radiological analysis.

    PubMed

    García-Rey, Eduardo

    2017-05-12

    Even with good surgical preparation, adequate primary stability of the acetabular component is not always achieved after primary total hip replacement (THR). We hypothesise that adequate bone preparation for appropriate cortical loading would allow us to avoid screw use. A total of 791 uncemented cups were analysed to compare the need for screws to obtain primary fixation in 5 different designs. Arthritic hips with inflammatory arthritis or severe congenital hip disease were excluded. A press-fit technique was first tried in all hips and screws were only used when strictly needed. Radiological acetabular shape and postoperative cup position were assessed in all hips. The mean follow-up was 9.6 (5-15) years. Screws were required in 155 hips (19.6%). We could not detect any difference in the percentage of screw use between designs. We found that female patients (odds ratio [OR] 2.06; 95% confidence interval [CI], 1.41-3.02) and cups with a greater distance to the hip rotation centre on the postoperative radiograph (OR 1.69; 95% CI, 1.17-2.45) had a higher risk for screw use. A greater anteversion of the cup had a lower risk for screw use (OR 0.96; 95% CI, 0.94-0.99). At latest follow-up no hips had needed revision for aseptic loosening. Good intraoperative technique is not enough to avoid screw use since more accurate cup position and reconstruction of the hip rotation centre are required for an adequate interference fit. A press-fit technique can provide similar mid-term results to screw use in hips without severe deformities.

  18. Comparison of Downstream Health Care Utilization, Costs, and Long-Term Opioid Use: Physical Therapist Management Versus Opioid Therapy Management After Arthroscopic Hip Surgery.

    PubMed

    Rhon, Daniel I; Snodgrass, Suzanne J; Cleland, Joshua A; Greenlee, Tina A; Sissel, Charles D; Cook, Chad E

    2018-05-01

    Physical therapy and opioid prescriptions are common after hip surgery, but are sometimes delayed or not used. The objective of this study was to compare downstream health care utilization and opioid use following hip surgery for different patterns of physical therapy and prescription opioids. The design of this study was an observational cohort. Health care utilization was abstracted from the Military Health System Data Repository for patients who were 18 to 50 years old and were undergoing arthroscopic hip surgery between 2004 and 2013. Patients were grouped into those receiving an isolated treatment (only opioids or only physical therapy) and those receiving both treatments on the basis of timing (opioid first or physical therapy first). Outcomes included overall health care visits and costs, hip-related visits and costs, additional surgeries, and opioid prescriptions. Of 1870 total patients, 82.7% (n = 1546) received physical therapy only, 71.6% (n = 1339) received prescription opioids, and 1073 (56.1%) received both physical therapy and opioids. Because 24 patients received both opioids and physical therapy on the same day, they were eventually removed the final timing-of-care analysis. Adjusted hip-related mean costs were the same in both groups receiving isolated treatments (${\\$}$11,628 vs ${\\$}$11,579), but the group receiving only physical therapy had significantly lower overall total health care mean costs (${\\$}$18,185 vs ${\\$}$23,842) and fewer patients requiring another hip surgery. For patients receiving both treatments, mean hip-related downstream costs were significantly higher in the group receiving opioids first than in the group receiving physical therapy first (${\\$}$18,806 vs ${\\$}$16,955) and resulted in greater opioid use (7.83 vs 4.14 prescriptions), greater total days' supply of opioids (90.17 vs 44.30 days), and a higher percentage of patients with chronic opioid use (69.5% vs 53.2%). Claims data were limited by the accuracy of coding, and observational data limit inferences of causality. Physical therapy first was associated with lower hip-related downstream costs and lower opioid use than opioids first; physical therapy instead of opioids was associated with less total downstream health care utilization. These results need to be validated in prospective controlled trials.

  19. The association between lower extremity energy absorption and biomechanical factors related to anterior cruciate ligament injury.

    PubMed

    Norcross, Marc F; Blackburn, J Troy; Goerger, Benjamin M; Padua, Darin A

    2010-12-01

    Greater total energy absorption by the lower extremity musculature during landing may reduce stresses placed on capsuloligamentous tissues with differences in joint contributions to energy absorption potentially affecting anterior cruciate ligament injury risk. However, the relationships between energy absorption and prospectively identified biomechanical factors associated with non-contact anterior cruciate ligament injury have yet to be demonstrated. Sagittal plane total, hip, knee and ankle energy absorption, and peak vertical ground reaction force, anterior tibial shear force, knee flexion and knee valgus angles, and internal hip extension and knee varus moments were measured in 27 individuals (14 females, 13 males) performing double leg jump landings. Correlation coefficients assessed the relationships between energy absorption during three time intervals (initial impact phase, terminal phase, and total landing) and biomechanical factors related to anterior cruciate ligament injury. More favorable values of biomechanical factors related to non-contact anterior cruciate ligament injury were associated with: 1) Lesser total (R(2)=0.178-0.558), hip (R(2)=0.229-0.651) and ankle (R(2)=0.280), but greater knee (R(2)=0.147) energy absorption during the initial impact phase; 2) Greater total (R(2)=0.170-0.845), hip (R(2)=0.599), knee (R(2)=0.236-0.834), and ankle (R(2)=0.276) energy absorption during the terminal phase of landing; and 3) Greater knee (R(2)=0.158-0.709), but lesser hip (R(2)=0.309) and ankle (R(2)=0.210-0.319) energy absorption during the total landing period. These results suggest that biomechanical factors related to anterior cruciate ligament injury are influenced by both the magnitude and timing of lower extremity energy absorption during landing. Copyright © 2010 Elsevier Ltd. All rights reserved.

  20. Huntingtin interacting protein 1 as a histopathologic adjunct in the diagnosis of Merkel cell carcinoma.

    PubMed

    Marghalani, Siham; Feller, John Kyle; Mahalingam, Meera; Mirzabeigi, Marjan

    2015-06-01

    Huntington interacting protein 1 (HIP1), an antiapoptotic protein normally expressed in the brain, is highly expressed in Merkel cell carcinomas (MCCs). Given this, the aim of the current study was to ascertain the value of HIP1 as a histopathologic adjunct in the diagnosis of MCC. In this retrospective study, archival material from 26 cases with a diagnosis of MCC and/or neuroendocrine carcinoma were retrieved from the pathology files of the Skin Pathology Laboratory (Boston University School of Medicine, Boston, MA, USA). Histopathologic sections of all cases were re-reviewed and the diagnosis confirmed. All patient data were de-identified. Immunohistochemical studies were performed using antibodies to HIP1 and cytokeratins (CK) 20 and 7. A semiquantitative scoring system for immunohistochemical expression of HIP1 was utilized by deriving a cumulative score (based on percentage positivity of cells and intensity of expression). Using a cut-off total score of 3 or more as positive, the total number of positive cases was 22 for HIP1, 24 for CK20, and 11 for CK7. Comparing the results of HIP1 and CK20, there were four discordant pairs (three positive for CK20 but negative for HIP1 and one positive for HIP1 but negative for CK20). McNemar's test indicated that there was no statistical significance (P = 0.625), thereby implying a close agreement between the expression of HIP1 and CK20 in these neuroendocrine neoplasms. © 2014 The International Society of Dermatology.

  1. Ultrasound screening of periarticular soft tissue abnormality around metal-on-metal bearings.

    PubMed

    Nishii, Takashi; Sakai, Takashi; Takao, Masaki; Yoshikawa, Hideki; Sugano, Nobuhiko

    2012-06-01

    Although metal hypersensitivity or pseudotumors are concerns for metal-on-metal (MoM) bearings, detailed pathologies of patterns, severity, and incidence of periprosthetic soft tissue lesions are incompletely understood. We examined the potential of ultrasound for screening of periarticular soft tissue lesions around MoM bearings. Ultrasound examinations were conducted in 88 hips (79 patients) with MoM hip resurfacings or MoM total hip arthroplasties with a large femoral head. Four qualitative ultrasound patterns were shown, including normal pattern in 69 hips, joint-expansion pattern in 11 hips, cystic pattern in 5 hips, and mass pattern in 3 hips. Hips with the latter 3 abnormal patterns showed significantly higher frequency of clinical symptoms, without significant differences of sex, duration of implantation, head sizes, and cup abduction/anteversion angles, compared with hips with normal pattern. Ultrasound examination provides sensitive screening of soft tissue reactions around MoM bearings and may be useful in monitoring progression and defining treatment for periarticular soft tissue abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Can Arthroplasty Stem INfluence Outcome? (CASINO): a randomized controlled equivalence trial of 125 mm versus 150 mm Exeter V40 stems in total hip arthroplasty.

    PubMed

    Hamilton, David F; Ohly, Nicholas E; Gaston, Paul

    2018-04-16

    The use of shorter length femoral stems during total hip arthroplasty has been suggested to accommodate wider patient femoral geometry and offer maximal bone preservation. However, cemented short-stem designs may increase the risk of varus stem malalignment and influence patient outcomes. CASINO is a multi-centre randomised equivalence trial that will recruit 220 patients undergoing total hip arthroplasty for osteoarthritis at two NHS hospitals in Scotland. Patients will be aged 45-80, undergoing unilateral primary hip arthroplasty, with no plan for contralateral procedure within the study timeframe, and able to comply with the protocol. Participants will be randomised to receive either a short (125 mm) or a standard (150 mm) Exeter V40 stem. The Contemporary acetabular component will be used in all cases. All implants will be cemented. Patient pain, function and satisfaction will be assessed using change from baseline measurement in Oxford Hip Score, Forgotten Joint Score, EQ-5D, pain numerical rating scores, and patient satisfaction questionnaire at baseline and at 1 and 2 years following surgery. Radiographic assessment will evaluate stem position and will be appraised by independent reviewers. Patients will be blind to implant allocation. Stem length may be associated with outcome; however, we can find no randomised trial in which researchers investigated the effect of stem length on patient outcome following cemented total hip arthroplasty. The aim of this trial is to determine if the use of short cemented stems offers equivalent patient outcomes to those achieved following surgery with standard length stems. International Standard Randomised Controlled Trial Number, ISRCTN13154542 , Registered on 30 June 2017.

  3. Photobiomodulation therapy (PBMT) on acute pain and inflammation in patients who underwent total hip arthroplasty-a randomized, triple-blind, placebo-controlled clinical trial.

    PubMed

    Langella, Luciana Gonçalves; Casalechi, Heliodora Leão; Tomazoni, Shaiane Silva; Johnson, Douglas Scott; Albertini, Regiane; Pallotta, Rodney Capp; Marcos, Rodrigo Labat; de Carvalho, Paulo de Tarso Camillo; Leal-Junior, Ernesto Cesar Pinto

    2018-06-16

    When conservative treatments fail, hip osteoarthritis (OA), a chronic degenerative disease characterized by cartilage wear, progressive joint deformity, and loss of function, can result in the need for a total hip arthroplasty (THA). Surgical procedures induced tissue trauma and incite an immune response. Photobiomodulation therapy (PBMt) using low-level laser therapy (LLLT) and/or light-emitting diode therapy (LEDT) has proven effective in tissue repair by modulating the inflammatory process and promoting pain relief. Therefore, the aim of this study was to analyze the immediate effect of PBMt on inflammation and pain of patients undergoing total hip arthroplasty. The study consisted of 18 post-surgical hip arthroplasty patients divided into two groups (n = 9 each) placebo and active PBMt who received one of the treatments in a period from 8 to 12 h following THA surgery. PBMt (active or placebo) was applied using a device consisting of nine diodes (one super-pulsed laser of 905 nm, four infrared LEDs of 875 nm, and four red LEDs 640 nm, 40.3 J per point) applied to 5 points along the incision. Visual analog scale (VAS) and blood samples for analysis of the levels of the cytokines TNF-α, IL-6, and IL-8 were recorded before and after PBMt application. The values for the visual analog scale as well as those in the analysis of TNF-α and IL-8 serum levels decreased in the active PBMt group compared to placebo-control group (p < 0.05). No decrease was observed for IL-6 levels. We conclude that PBMt is effective in decreasing pain intensity and post-surgery inflammation in patients receiving total hip arthroplasty.

  4. Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial.

    PubMed

    Howie, Donald W; Holubowycz, Oksana T; Middleton, Robert

    2012-06-20

    The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference, 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established.

  5. Reduced survival for uncemented compared to cemented total hip arthroplasty after operatively treated acetabular fractures.

    PubMed

    Clarke-Jenssen, John; Westberg, Marianne; Røise, Olav; Storeggen, Stein Arne Øvre; Bere, Tone; Silberg, Ingunn; Madsen, Jan Erik

    2017-11-01

    Post traumatic arthritis and avascular necrosis of the femoral head are common complications after operatively treated acetabular fractures. This may cause severe disabilities for the patient, necessitating a total hip arthroplasty. Even though an arthroplasty may provide good symptomatic relief, the long-term results are more uncertain and no consensus exists according to preferred prosthetic designs. With this cohort study, we aimed to investigate the medium to long term arthroplasty survival and clinical results of total hip arthroplasty after operatively treated acetabular fractures. We included 52 patients treated with a secondary total hip arthroplasty at a median of 2.4 (0.1-14.1) years after an operatively treated acetabular fracture. The median age was 54 (11-82) years. Cemented arthroplasty was used for 33 patients, 10 patients had an uncemented arthroplasty and 9 patients received a hybrid arthroplasty. Average follow up was 8.0 (SD 5.0) years. Ten-year revision free arthroplasty survival was 79%. Uncemented arthroplasties had a significantly worse 10-year survival of 57%. Arthroplasties performed at a centre without a pelvic fracture service also had a significantly worse 10-years survival of 51%. Cox regression showed similar results with an 8-fold increase in risk of revision for both uncemented arthroplasties and operations performed at a non-pelvic trauma centre. Total hip arthroplasty secondary to an operatively treated acetabular fracture provides good symptomatic relief. These patients are, however, complex cases and are probably best treated at specialist centres with both pelvic trauma surgeons and arthroplasty surgeons proficient in complex revisions present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Handball Practice Enhances Bone Mass in Specific Sites Among Prepubescent Boys.

    PubMed

    Missawi, Kawther; Zouch, Mohamed; Chakroun, Yosra; Chaari, Hamada; Tabka, Zouhair; Bouajina, Elyès

    2016-01-01

    This investigation's purpose is to focus on the effects of practicing handball for at least 2 yr on bone acquisition among prepubescent boys. One hundred prepubescent boys aged 10.68 ± 0.85 yr were divided into 2 groups: 50 handball players (HP group) and 50 controls (C group). Bone mineral density (BMD), bone mineral content (BMC), and bone area (BA) were evaluated by using dual-photon X-ray absorptiometry on the whole body, lumbar spine (L2-L4), legs, arms, femoral necks, hips and radiuses. Results showed greater values of BMD in both right and left femoral neck and total hip in handball players than in controls. In addition, handball players had higher values of legs and right total hip BMC than controls without any obvious variation of BA measurement in all sites between groups. All results of the paired t-test displayed an obviously marked variation of bone mass parameters between the left and right sides in the trained group without any marked variation among controls. Data showed an increased BMD of the supporting sites between the left and the right leg among handball players. However, "BMC" results exhibited higher values in the right than in the left total hip, and in the right total radius than in the left correspondent site. In addition, differences in the "BA" measurements were observed in the left total hip and in the right arm. Specific bone sites are markedly stimulated by handball training in prepubescent boys. Copyright © 2016 International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  7. [Effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early osteonecrosis of the femoral head].

    PubMed

    Li, Ji; Li, Zhongli; Su, Xiangzheng; Liu, Chunhui; Zhang, Hao; Wang, Ketao

    2017-09-01

    To evaluate the effectiveness of multiple small-diameter drilling decompression combined with hip arthroscopy for early oeteonecrosis of the femoral head (ONFH). Between March 2010 and December 2013, 91 patients with early ONFH were treated with the operation of multiple small-diameter drilling decompression combined with hip arthroscopy in 39 cases (53 hips, group A) or with drilling decompression alone in 52 cases (74 hips, group B). The patients in 2 groups had obvious hip pain and limited motion before operation. There was no significant difference in gender, age, etiology, effected side, stage of osteonecrosis, and preoperative Harris score between 2 groups ( P >0.05). All operations succeeded and all incisions healed by first intention. The operation time was significantly longer in group A [(73.3±10.6) minutes] than in group B [(41.5±7.2) minutes] ( t =8.726, P =0.000). Temporary of sciatic nerve apraxia after operation occurred in 2 patients of group A, and no complication occurred in other patients. Patients were followed up 24-52 months (mean, 39.3 months) in group A and 24-48 months (mean, 34.6 months) in group B. At last follow-up, the Harris scores were 83.34±8.76 in group A and 76.61±9.22 in group B, showing significant differences when compared between 2 groups ( t =-4.247, P =0.029) and when compared with preoperative values in 2 groups ( t =-10.327, P =0.001; t =-8.216, P =0.008). X-ray films showed that the collapse of the femoral head was observed in 6 hips (1 hip at stage Ⅰand 5 hips at stage Ⅱ) in group A, and in 16 hips (4 hips at stageⅠand 12 hips at stage Ⅱ) in group B; and hip arthroplasty was performed. The total effective rates were 88.68% (47/53) in group A and 78.38% (58/74) in group B, respectively; showing significant difference between 2 groups ( χ 2 =5.241, P =0.041). Multiple small-diameter drilling decompression combined with hip arthroscopy is effective in pain relief, improvement of hip function, slowing-down the process of femoral head necrosis, delaying the need for total hip arthroplasty in patients with early ONFH.

  8. The Exercise Plus Program for Older Women Post Hip Fracture: Participant Perspectives

    ERIC Educational Resources Information Center

    Resnick, Barbara; Orwig, Denise; Wehren, Lois; Zimmerman, Sheryl; Simpson, Marjorie; Magaziner, Jay

    2005-01-01

    Purpose: The purpose of this study was to explore the experiences of older women post hip fracture who were exposed to a motivational intervention, the Exercise Plus Program, intended to increase adherence to exercise. Design and Methods: This study used a naturalistic inquiry. We interviewed a total of 70 older women, 12 months post hip fracture,…

  9. Effect of cup inclination on predicted contact stress-induced volumetric wear in total hip replacement.

    PubMed

    Rijavec, B; Košak, R; Daniel, M; Kralj-Iglič, V; Dolinar, D

    2015-01-01

    In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.

  10. Achieving Consensus on Total Joint Replacement Trial Outcome Reporting Using the OMERACT Filter: Endorsement of the Final Core Domain Set for Total Hip and Total Knee Replacement Trials for Endstage Arthritis.

    PubMed

    Singh, Jasvinder A; Dowsey, Michelle M; Dohm, Michael; Goodman, Susan M; Leong, Amye L; Scholte Voshaar, Marieke M J H; Choong, Peter F

    2017-11-01

    Discussion and endorsement of the OMERACT total joint replacement (TJR) core domain set for total hip replacement (THR) and total knee replacement (TKR) for endstage arthritis; and next steps for selection of instruments. The OMERACT TJR working group met at the 2016 meeting at Whistler, British Columbia, Canada. We summarized the previous systematic reviews, the preliminary OMERACT TJR core domain set and results from previous surveys. We discussed preliminary core domains for TJR clinical trials, made modifications, and identified challenges with domain measurement. Working group participants (n = 26) reviewed, clarified, and endorsed each of the inner and middle circle domains and added a range of motion domain to the research agenda. TJR were limited to THR and TKR but included all endstage hip and knee arthritis refractory to medical treatment. Participants overwhelmingly endorsed identification and evaluation of top instruments mapping to the core domains (100%) and use of subscales of validated multidimensional instruments to measure core domains for the TJR clinical trial core measurement set (92%). An OMERACT core domain set for hip/knee TJR trials has been defined and we are selecting instruments to develop the TJR clinical trial core measurement set to serve as a common foundation for harmonizing measures in TJR clinical trials.

  11. Association of Body Weight and Body Mass Index with Bone Mineral Density in Women and Men from Kosovo.

    PubMed

    Rexhepi, Sylejman; Bahtiri, Elton; Rexhepi, Mjellma; Sahatciu-Meka, Vjollca; Rexhepi, Blerta

    2015-08-01

    Body weight and body mass index (BMI) are considered potentially modifiable determinants of bone mass. Therefore, the aim of this study was to explore the association between body weight and body mass index (BMI) with total hip and lumbar spine bone mineral density (BMD). This cross-sectional study included a population of 100 women and 32 men from Kosovo into three BMI groups. All the study subjects underwent dual-energy X-ray absorptiometry (DXA) measurements. Total hip BMD levels of obese menopausal and premenopausal women and men were significantly higher compared to overweight or normal weight subjects, while lumbar spine BMD levels of only menopausal women and men were higher among obese subjects. Age-adjusted linear regression analysis showed that BMI is a significant independent associate of lumbar spine and total hip BMD in menopausal women and men. Despite positive association between BMI and lumbar spine and total hip BMD in menopausal women, presence of more obese and osteoporotic subjects among menopausal women represent a population at risk for fractures because of poor balance and frequent falls; therefore, both obesity and osteoporosis prevention efforts should begin early on in life.

  12. [Minimally invasive approaches to hip and knee joints for total joint replacement].

    PubMed

    Rittmeister, M; König, D P; Eysel, P; Kerschbaumer, F

    2004-11-01

    The manuscript features the different minimally invasive approaches to the hip for joint replacement. These include medial, anterior, anterolateral, and posterior approaches. The concept of minimally invasive hip arthroplasty makes sense if it is an integral part of a larger concept to lower postoperative morbidity. Besides minimal soft tissue trauma, this concept involves preoperative patient education, preemptive analgesia, and postoperative physiotherapy. It is our belief that minimal incision techniques for the hip are not suited for all patients and all surgeons. The different minimally invasive approaches to the knee joint for implantation of a knee arthroplasty are described and discussed. There have been no studies published yet that fulfill EBM criteria. The data so far show that minimally invasive approaches and implantation techniques for total knee replacements lead to quicker rehabilitation of patients.

  13. Survivorship of the native hip joint after percutaneous repair of acetabular fractures in the elderly.

    PubMed

    Gary, Joshua L; Lefaivre, Kelly A; Gerold, Frank; Hay, Michael T; Reinert, Charles M; Starr, Adam J

    2011-10-01

    Our purpose was to examine survivorship of the native hip joint in patients ages 60 and over who underwent percutaneous reduction and fixation of acetabular fractures. A retrospective review at a University Level I Trauma Center was performed. Our institutional trauma database was reviewed. Patients aged 60 or older treated with percutaneous reduction and fixation of acetabular fractures between 1994 and 2007 were selected. 79 consecutive patients with 80 fractures were identified. Rate of conversion to total hip arthroplasty were used to construct a Kaplan-Meier curve showing survivorship of the native hip joint after treatment. 75 fractures had adequate clinical follow-up with a mean of 3.9 years (range 0.5-11.9 years). Average blood loss was 69 cc and there were no postoperative infections. 19/75 (25%) were converted to total hip arthroplasty at a mean time of 1.4 years after the index procedure. Survivorship analysis demonstrated a cumulative survival of 65% at 11.9 years of follow-up. There were no conversions to arthroplasty beyond 4.7 years postoperatively. There were no statistically significant associations between conversion to arthroplasty and age, sex, closed vs. limited open reduction, and simple vs. complex fracture pattern. Percutaneous fixation is a viable treatment option for patients age 60 or greater with acetabular fractures. Rates of conversion to total hip arthroplasty are comparable to open treatment methods and if conversion is required, soft tissues are preserved for future surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Early failure of total hip replacements implanted at distant hospitals to reduce waiting lists.

    PubMed Central

    Ciampolini, Jac; Hubble, Matthew J. W.

    2005-01-01

    AIM: In the years 1990-1993, in an effort to reduce waiting-list time, a small number of patients were sent from Exeter to hospitals in London to undergo elective total hip replacement. No medium- or long-term follow-up was arranged. Our aim was to audit the outcome of these hip replacements. PATIENTS AND METHODS: Review of the records of the referring medical practices, Regional Health Authority, local orthopaedic hospital and the distant centres at which the surgery was performed identified 31 cases. A total of 27 hip replacements in 24 patients were available for clinical and radiological review. RESULTS: 12 (44%) hips have so far required revision surgery, at a mean of 6.5 years. Of these, three (11%) have been for deep infection. A further three hips (11%) are radiologically loose and are being closely monitored. Two patients (7%) suffered permanent sciatic nerve palsy. CONCLUSIONS: Patients whose surgery was performed locally over a similar time period have a published failure rate of only 4.9%. This difference is highly statistically significant (P < 0.001). The causes for such a difference in outcome were analysed and include surgical technique, implant selection and absence of follow-up. In the light of this evidence, we would like to urge the government to address waiting list problems by investing in the local infrastructure. Expanding those facilities where properly audited and fully accountable surgeons operate must be the way forward. PMID:15720905

  15. Celecoxib versus ibuprofen in the prevention of heterotopic ossification following total hip replacement: a prospective randomised trial.

    PubMed

    Saudan, M; Saudan, P; Perneger, T; Riand, N; Keller, A; Hoffmeyer, P

    2007-02-01

    We examined whether a selective cyclooxygenase-2 (COX-2) inhibitor (celecoxib) was as effective as a non-selective inhibitor (ibuprofen) for the prevention of heterotopic ossification following total hip replacement. A total of 250 patients were randomised to receive celecoxib (200 mg b/d) or ibuprofen (400 mg t.d.s) for ten days after surgery. Anteroposterior radiographs of the pelvis were examined for heterotopic ossification three months after surgery. Of the 250 patients, 240 were available for assessment. Heterotopic ossification was more common in the ibuprofen group (none 40.7% (50), Brooker class I 46.3% (57), classes II and III 13.0% (16)) than in the celecoxib group (none 59.0% (69), Brooker class I 35.9% (42), classes II and III 5.1% (6), p=0.002). Celecoxib was more effective than ibuprofen in preventing heterotopic bone formation after total hip replacement.

  16. Hip protector compliance: a 13-month study on factors and cost in a long-term care facility.

    PubMed

    Burl, Jeffrey B; Centola, James; Bonner, Alice; Burque, Colleen

    2003-01-01

    To determine if a high compliance rate for wearing external hip protectors could be achieved and sustained in a long-term care population. A 13-month prospective study of daytime use of external hip protectors in an at-risk long-term care population. One hundred-bed not-for-profit long-term care facility. Thirty-eight ambulatory residents having at least 1 of 4 risk factors (osteoporosis, recent fall, positive fall screen, previous fracture). The rehabilitation department coordinated an implementation program. Members of the rehabilitation team met with eligible participants, primary caregivers, families, and other support staff for educational instruction and a description of the program. The rehabilitation team assumed overall responsibility for measuring and ordering hip protectors and monitoring compliance. By the end of the third month, hip protector compliance averaged greater than 90% daily wear. The average number of falls per month in the hip protector group was 3.9 versus 1.3 in nonparticipants. Estimated total indirect staff time was 7.75 hours. The total cost of the study (hip protectors and indirect staff time) was 6,300 US dollars. High hip protector compliance is both feasible and sustainable in an at-risk long-term care population. Achieving high compliance requires an interdisciplinary approach with one department acting as a champion. The cost of protectors could be a barrier to widespread use. Facilities might be unable to cover the cost until the product is paid for by third-party payers.

  17. Primary Stability Recognition of the Newly Designed Cementless Femoral Stem Using Digital Signal Processing

    PubMed Central

    Salleh, Sh-Hussain; Hamedi, Mahyar; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Mohd Noor, Alias; Harris, Arief Ruhullah A.; Abdul Majid, Norazman

    2014-01-01

    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing. PMID:24800230

  18. Primary stability recognition of the newly designed cementless femoral stem using digital signal processing.

    PubMed

    Baharuddin, Mohd Yusof; Salleh, Sh-Hussain; Hamedi, Mahyar; Zulkifly, Ahmad Hafiz; Lee, Muhammad Hisyam; Mohd Noor, Alias; Harris, Arief Ruhullah A; Abdul Majid, Norazman

    2014-01-01

    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.

  19. Effectiveness of multimodal pain management after bipolar hemiarthroplasty for hip fracture: a randomized, controlled study.

    PubMed

    Kang, Hyun; Ha, Yong-Chan; Kim, Jin-Yun; Woo, Young-Cheol; Lee, Jae-Sung; Jang, Eui-Chan

    2013-02-20

    Appropriate pain management affects outcome after hip fracture surgery. Although multimodal pain management is commonly used for pain control for patients undergoing elective surgery, few studies have evaluated its use in those undergoing hip fracture surgery. This prospective randomized study was designed to determine the clinical value of multimodal pain management with preemptive pain medication and intraoperative periarticular multimodal drug injections in patients undergoing bipolar hip hemiarthroplasty. Of eighty-two cognitively intact elderly patients about to undergo bipolar hemiarthroplasty after a hip fracture, forty-three were randomly assigned to receive preemptive pain medication and intraoperative periarticular injections (Group I) and thirty-nine were assigned to not receive preemptive medication and injections (Group II). These two groups were compared with regard to the pain level on postoperative days one, four, and seven; at discharge; and when they started walking and standing exercises. Total amounts of fentanyl used, the frequency of use of patient-controlled analgesia, patient satisfaction at discharge, and perioperative complications were recorded. Group I had a lower pain level than Group II on postoperative days one and four, but no intergroup difference in pain level was observed on postoperative day seven. The total amount of fentanyl used and the frequency of use of patient-controlled analgesia were also lower in Group I. Patient satisfaction at discharge was higher in Group I. No significant intergroup differences were found in the times until the patients walked or performed standing exercises or in the complications. Multimodal pain management provides additional pain relief until the fourth postoperative day, improves patient satisfaction at discharge, and reduces total narcotic consumption for postoperative pain management after hip hemiarthroplasty for hip fractures.

  20. Bone marrow edema pattern in advanced hip osteoarthritis: quantitative assessment with magnetic resonance imaging and correlation with clinical examination, radiographic findings, and histopathology.

    PubMed

    Taljanovic, Mihra S; Graham, Anna R; Benjamin, James B; Gmitro, Arthur F; Krupinski, Elizabeth A; Schwartz, Stephanie A; Hunter, Tim B; Resnick, Donald L

    2008-05-01

    To correlate the amount of bone marrow edema (BME) calculated by magnetic resonance imaging(MRI) with clinical findings, histopathology, and radiographic findings, in patients with advanced hip osteoarthritis(OA). The study was approved by The Institutional Human Subject Protection Committee. Coronal MRI of hips was acquired in 19 patients who underwent hip replacement. A spin echo (SE) sequence with four echoes and separate fast spin echo (FSE) proton density (PD)-weighted SE sequences of fat (F) and water (W) were acquired with water and fat suppression, respectively. T2 and water:fat ratio calculations were made for the outlined regions of interest. The calculated MRI values were correlated with the clinical, radiographic, and histopathologic findings. Analyses of variance were done on the MRI data for W/(W + F) and for T2 values (total and focal values) for the symptomatic and contralateral hips. The values were significantly higher in the study group. Statistically significant correlations were found between pain and total W/(W + F), pain and focal T2 values, and the number of microfractures and calculated BME for the focal W/(W + F) in the proximal femora. Statistically significant correlations were found between the radiographic findings and MRI values for total W/(W + F), focal W/(W + F) and focal T2 and among the radiographic findings, pain, and hip movement. On histopathology, only a small amount of BME was seen in eight proximal femora. The amount of BME in the OA hip, as measured by MRI, correlates with the severity of pain, radiographic findings, and number of microfractures.

  1. The effects of different nutritional measurements on delayed wound healing after hip fracture in the elderly.

    PubMed

    Guo, Jiong Jiong; Yang, Huilin; Qian, Haixin; Huang, Lixin; Guo, Zhongxing; Tang, Tiansi

    2010-03-01

    It has been well recognized that malnutrition causes wounds to heal inadequately and incompletely. Malnutrition is often observed in the elderly, and it appears to be more severe in patients with hip fracture than in the general aging population. Few prospective studies give a detailed account of the identification and classification of nutritional status in the elderly. The objective of this study was to evaluate the effects of different nutritional measurements on wound healing status after hip fracture in the elderly. From September 2002 to December 2007, 207 hip fracture patients older than 60 y treated surgically were reviewed for preoperative nutritional status. There were 81 males and 126 females with an average age of 75.93 y (62-91 y); 131 cases with femoral neck fractures, 76 cases with intertrochanteric fractures. Parameters indicative of nutritional status (serum albumin, serum transferrin, serum pre-albumin, and total lymphocyte count levels) at the time of admission were assessed, along with anthropometric measurements, Rainey MacDonald nutritional index, and MNA tool. Suture removal was performed on postoperative day 14. Delayed wound healing complicated 46 (22.2%) of the 207 cases. The preoperative serum transferring total lymphocyte count levels, MNA total score, and Rainey MacDonald nutritional index were significantly lower for patients who subsequently had delayed wound healing. When all variables were subjected to multivariate analysis, only total lymphocyte count levels and MNA total score showed significant value in predicting which patients would have delayed wound healing. Through prophylactic antibiotics and adherence to strict aseptic precautions, on follow-up, wound healing was normal in all patients. Patients at risk for delayed wound healing problems after hip fracture can be identified using relatively inexpensive laboratory test such as TLC and MNA tool. The clinician must be aware of the risk values of both measurements. We believe this information is particularly important before planning procedures of hip fractures in the elderly. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  2. Intra-articular steroid injection for osteoarthritis of the hip prior to total hip arthroplasty : is it safe? a systematic review.

    PubMed

    Pereira, L C; Kerr, J; Jolles, B M

    2016-08-01

    Using a systematic review, we investigated whether there is an increased risk of post-operative infection in patients who have received an intra-articular corticosteroid injection to the hip for osteoarthritis prior to total hip arthroplasty (THA). Studies dealing with an intra-articular corticosteroid injection to the hip and infection following subsequent THA were identified from databases for the period between 1990 to 2013. Retrieved articles were independently assessed for their methodological quality. A total of nine studies met the inclusion criteria. Two recommended against a steroid injection prior to THA and seven found no risk with an injection. No prospective controlled trials were identified. Most studies were retrospective. Lack of information about the methodology was a consistent flaw. The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35. ©2016 The British Editorial Society of Bone & Joint Surgery.

  3. [Influence of Training of Orthopaedic Surgeons on Clinical Outcome after Total Hip Arthroplasty in a High Volume Endoprosthetic Centre].

    PubMed

    Osmanski-Zenk, Katrin; Finze, Susanne; Lenz, Robert; Bader, Rainer; Mittelmeier, Wolfram

    2018-06-26

    The study aims to evaluate whether the postoperative outcome and the probability of complications of patients with total hip arthroplasty increases significantly when surgeons in training are in charge, assisted by a high volume surgeon, compared to a highly experienced orthopaedic surgeon, within the context of a high volume hospital certified to EndoCert. 192 patients with a primary hip arthroplasty were included. To assess the outcome, the Harris Hip Score, WOMAC, SF-36 and EuroQol-5D were surveyed pre- and 12 months postoperatively. As complications we considered the quality indicators defined by EndoCert. We found significant improvements in the postoperative score values with the qualifications of the surgeon in charge, even when a high volume surgeon or a surgeon in training was responsible. If a surgeon in training is assisted by a highly experienced surgeon, the risk of complications does not increase, although the operating time was significantly increased. Both the surgeon in training as well as the arthroplasty patient benefit from implementing the EndoCert system, because the postoperative outcome and the complication probability is independent of the qualifcation of the operating orthopaedic surgeon performing total hip arthroplasty when assisted by an experienced surgeon. Georg Thieme Verlag KG Stuttgart · New York.

  4. Translation, cross-cultural adaptation, and psychometric properties of the German version of the hip disability and osteoarthritis outcome score.

    PubMed

    Blasimann, Angela; Dauphinee, Sharon Wood; Staal, J Bart

    2014-12-01

    Clinical measurement. To translate and cross-culturally adapt the Hip disability and Osteoarthritis Outcome Score (HOOS) from English into German, and to study its psychometric properties in patients after hip surgery. There is no specific hip questionnaire in German that not only measures symptoms and function but also contains items about hip-related quality of life. The translation and cross-cultural adaptation involved forward translation, harmonization, cognitive debriefing, back translation, and comparison to the original HOOS following international guidelines. The German version was tested in 51 Swiss inpatients 8 weeks after different types of hip surgery, mainly total hip replacement. The mean age of the participants was 62.5 years, and the age range was from 27 to 87 years. Thirty (58.8%) of the participants were women. Internal consistency and test-retest reliability were estimated using Cronbach alpha and intraclass correlation coefficients for agreement. For construct validity, total scores of the German HOOS were correlated with those of the Western Ontario and McMaster Universities Osteoarthritis Index. The HOOS was also compared to the Medical Outcomes Study 36-Item Short-Form Health Survey. Cronbach alpha values for all German HOOS subscales were between .87 and .93. For test-retest reliability, the intraclass correlation coefficient for agreement was 0.85 for the total scores of the German HOOS. The Spearman rho for the Medical Outcomes Study 36-Item Short-Form Health Survey physical functioning subscale compared to the sum of all HOOS subscales was 0.71, and that for the Medical Outcomes Study 36-Item Short-Form Health Survey physical component summary was 0.97. The German HOOS has demonstrated adequate reliability and validity. Use of the German HOOS is recommended for assessment of patients after hip surgery, with the proviso that additional psychometric testing should be done in future research.

  5. Newer anesthesia and rehabilitation protocols enable outpatient hip replacement in selected patients.

    PubMed

    Berger, Richard A; Sanders, Sheila A; Thill, Elizabeth S; Sporer, Scott M; Della Valle, Craig

    2009-06-01

    Advancements in the surgical approach, anesthetic technique, and the initiation of rapid rehabilitation protocols have decreased the duration of hospitalization and subsequent length of recovery following elective total hip arthroplasty. We assessed the feasibility and safety of outpatient total hip arthroplasty in 150 consecutive patients. A comprehensive perioperative anesthesia and rehabilitation protocol including preoperative teaching, regional anesthesia, and preemptive oral analgesia and antiemetic therapy was implemented around a minimally invasive surgical technique. A rapid rehabilitation pathway was started immediately after surgery and patients had the option of being discharged to home the day of surgery if standard discharge criteria were met. All 150 patients were discharged to home the day of surgery, at which time 131 patients were able to walk without assistive devices. Thirty-eight patients required some additional intervention outside the pathway to resolve nausea, hypotension, or sedation prior to discharge. There were no readmissions for pain, nausea, or hypotension yet there was one readmission for fracture and nine emergency room evaluations in the three month perioperative period. This anesthetic and rehabilitation protocol allowed outpatient total hip arthroplasty to be routinely performed in these consecutive patients undergoing primary total hip arthroplasty. With current reimbursement approaches the modest savings to the hospital in length of stay may be outweighed by the additional costs of personnel, thereby making this outpatient system more expensive to implement. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  6. How much arthritis is too much for hip arthroscopy: a systematic review.

    PubMed

    Domb, Benjamin G; Gui, Chengcheng; Lodhia, Parth

    2015-03-01

    The purpose of this study was to determine the extent of preoperative osteoarthritis (OA) that precludes benefit from hip arthroscopy by systematically reviewing the literature on hip arthroscopy in the setting of OA. We searched the Medline and PubMed databases using the following Medical Subject Heading terms: arthritis, osteoarthritis, chondral damage, chondral injury, chondral delamination, and hip arthroscopy. Two authors independently reviewed the literature and included articles if they were in the English language; commented on preoperative factors, parameters, physical examination, or diagnostic testing that may be evidence of cartilage damage and/or arthritis; contained outcome data on patients undergoing hip arthroscopy; and had a sample size of at least 10 patients with arthritic changes in the hip. We excluded review articles, technique articles, articles with overlapping patient populations, articles with hip arthroscopy used as an adjunct to an open procedure, articles with inflammatory and septic arthritis, and articles with a mean age younger than 18 years. Our search identified 518 articles, of which 15 met the inclusion and exclusion criteria. Two thousand fifty-one hips underwent arthroscopy at a mean patient age of 40.2 years. Of these, 1,195 hips had signs of OA. There were 345 conversions to total hip arthroplasty/surface replacement arthroplasty. Of these patients, 274 had OA. Eight patient-reported outcome instruments were used. Factors influencing outcomes were preoperative OA, age, chondral damage, femoroacetabular impingement, and duration of symptoms. Current evidence is insufficient to define a cutoff for how much arthritis is too much for hip arthroscopy. However, this analysis shows that patients with a Tönnis grade of 1 or greater or a joint space of 2 mm or less are less likely to benefit from hip arthroscopy and more likely to require conversion to total hip arthroplasty/surface replacement arthroplasty. Postoperative scores on patient-reported outcome instruments are lower in the arthritic population at follow-up compared with their nonarthritic counterparts. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. [Short-term curative effects of Tantalum rod treatment in early avascular necrosis].

    PubMed

    Ye, Fu-Sheng; Ni, Zhe-Ji; Chu, Xiao-Bing; He, Bang-Jian; Li, Ju; Tong, Pei-Jian

    2013-08-01

    To explore the recent clinical curative effect of Tantalum rod in treating the early avascular necrosis. From January 2008 to November 2008, the 25 patients (39 hips) with early avascular necrosis accepted tantalum rod placement and included 9 males (11 hips) and 16 females (28 hips) with an average age of 37 years old ranging from 18 to 74 years old. Four patients (6 hips) caused by Alcoholic, 6 patients (8 hips) by hormone, 2 cases (2 hips) by traumatic, 13 cases (23 hips) by idiopathic. Steinberg preoperative stage involved 7 hips in period I, 24 hips in period II, 8 hips in period III. Curative effect analysis included preoperative and postoperative Harris score, radiographic changes and hip replacement for follow-up to accept the end of the femoral head survival rate. All patients were followed up for 6 to 47 months (averaged 37.4 months). All 12 hips imaging appeard progress,including tantalum rod exit in 1 hip, hip hemiarthroplasty collapse in 3 hips, the area increased to avascular necrosis in 8 hips. Six hips accepted total hip replacement, including imaging progress in 5 hips (41.7%, 5/12), no imaging progress in 1 hip (3.7%,1/27). All hips' Kaplan-Meier survival curves showed 6-month survival rate was (97.4 +/- 2.5)% after tantalum stick insertion, 1-year survival rate was (94.7 +/- 3.6), and 2-year survival rate was (88.6 +/- 5.4)%, 3-year survival rate was (72.5 +/- 11.2). It is effective for treatment of avascular necrosis of femoral head in Steinberg I and II by Tantalum rod, and it can effectively relieve femoral head replacement time.

  8. Etidronate

    MedlinePlus

    ... the skeleton) in people who have had total hip replacement surgery (surgery to replace the hip joint with an artificial joint) or in people ... 8 ounces [180 to 240 mL]) of plain water while you are sitting or standing. Sit or ...

  9. Hip fracture prevalence in grandfathers is associated with reduced cortical cross-sectional bone area in their young adult grandsons.

    PubMed

    Rudäng, Robert; Ohlsson, Claes; Odén, Anders; Johansson, Helena; Mellström, Dan; Lorentzon, Mattias

    2010-03-01

    Parent hip fracture prevalence is a known risk factor for osteoporosis. The role of hip fracture prevalence in grandparents on areal bone mineral density (aBMD) and bone size in their grandsons remains unknown. The objective of the study was to examine whether hip fracture prevalence in grandparents was associated with lower aBMD and reduced cortical bone size in their grandsons. This was a population-based cohort study in Sweden. Subjects included 1015 grandsons (18.9 +/- 0.6) (mean +/- sd) and 3688 grandparents. aBMD, cortical bone size, volumetric bone mineral density and polar strength strain index of the cortex in the grandsons in relation to hip fracture prevalence in their grandparents were measured. Grandsons of grandparents with hip fracture (n = 269) had lower aBMD at the total body, radius, and lumbar spine, but not at the hip, as well as reduced cortical cross-sectional area at the radius (P < 0.05) than grandsons of grandparents without hip fracture. Subgroup analysis demonstrated that grandsons of grandfathers with hip fracture (n = 99) had substantially lower aBMD at the lumbar spine (4.9%, P < 0.001) and total femur (4.1%, P = 0.003) and lower cortical cross-sectional area of the radius (4.1%, P < 0.001) and tibia (3.3%, P < 0.011). Adjusting bone variables for grandson age, weight, height, smoking, calcium intake, and physical activity and taking grandparent age at register entry, years in register, and grandparent sex into account strengthened or did not affect these associations. Family history of a grandfather with hip fracture was associated with reduced aBMD and cortical bone size in 19-yr-old men, indicating that patient history of hip fracture in a grandfather could be of value when evaluating the risk of low bone mass in men.

  10. HIP AND GLENOHUMERAL PASSIVE RANGE OF MOTION IN COLLEGIATE SOFTBALL PLAYERS

    PubMed Central

    Plummer, Hillary; Brambeck, Allison

    2016-01-01

    Background and Purpose Range of motion deficits at the hip and glenohumeral joint (GHJ) may contribute to the incidence of injury in softball players. With injury in softball players on the rise, softball related studies in the literature are important. The purpose of this study was to examine hip and GHJ passive range of motion (PROM) patterns in collegiate softball players. Hypothesis It was hypothesized that the position players would exhibit significantly different PROM patterns than pitchers. Additionally, position players would exhibit significantly different side-to-side differences in PROM for both the hip and GHJ compared to pitchers. Study Design Prospective cohort study. Methods Forty-nine collegiate softball players (19.63 ± 1.15 years; 170.88 ± 8.08 cm; 72.96 ± 19.41 kg) participated. Passive hip and GHJ internal (IR) and external rotation (ER) measures were assessed. Glenohumeral PROM was measured with the participants supine with the arm abducted to 90 °. The measurements were recorded when the scapula began to move or a firm capsular end-feel was achieved. The hip was positioned in 90 ° of flexion and passively rotated until a capsular end-feel was achieved. Total PROM was calculated by taking the sum of IR and ER for both the hip and GHJ. Results No significant side-to-side PROM differences were observed in pitchers, at the GHJ or hip joint. Position players throwing side hip IR was significantly greater than the non-throwing side hip (p = 0.002). The non-throwing side hip had significantly greater ER compared to the throwing side hip (p = 0.002). When examining side-to-side differences at the GHJ, IR was significantly greater in the non-throwing shoulder (p = 0.047). No significant differences in total range of motion of the hip and GHJ were observed. Conclusion In the current study, position players displayed side-to-side differences in hip and GHJ IR PROM while no statistically significant differences were observed in the softball pitchers. The findings of the current study add to the body of literature related to PROM in throwing athletes, additionally these are the first hip IR and ER PROM data presented in softball players. Level of Evidence Level 3 PMID:27757286

  11. Anticipatory postural adjustments during lateral step motion in patients with hip osteoarthritis.

    PubMed

    Tateuchi, Hiroshige; Ichihashi, Noriaki; Shinya, Masahiro; Oda, Shingo

    2011-02-01

    Patients with hip osteoarthritis (OA) have difficulty with mediolateral postural control. Since the symptom of hip OA includes joint pain, which mostly occurs upon initial movement, patients with hip OA might have disabling problems with movement initiation. This study aimed to identify the movement strategy during the anticipatory postural adjustments in the lateral step motion in patients with hip OA. We studied 18 female subjects with unilateral hip OA and 10 healthy subjects, and measured temporal, kinetic, and kinematic variables. Patients with hip OA required a longer duration of anticipation phase than the control subjects, the total duration of lateral stepping was not different between the groups. Displacement of the center of mass to the supporting (affected) side during the anticipation phase was not different between the two groups. These findings suggest that, in patients with hip OA, the center of mass slowly moved to the affected side. Furthermore, patients with hip OA showed greater shift of the trunk to the supporting side than did the control subjects. These movement characteristics might contribute to the achievement of both protection of the affected hip joint and quickness in the subsequent lateral step in patients with hip OA.

  12. Bone Remodeling in Acetabular Reconstruction Using a Kerboull-Type Reinforcement Device and Structural Bone-Grafting in Total Hip Arthroplasty.

    PubMed

    Oe, Kenichi; Iida, Hirokazu; Tsuda, Kohei; Nakamura, Tomohisa; Okamoto, Naofumi; Ueda, Yusuke

    2017-03-01

    The purpose of this study was to identify the long-term durability of the Kerboull-type reinforcement device (KT plate) in acetabular reconstruction for massive bone defects, assessing the remodeling of structural bone grafts. This study retrospectively evaluated 106 hips that underwent acetabular reconstruction using a KT plate between November 2000 and December 2010. Thirty-eight primary total hip arthoplasties (THAs) and 68 revised THAs were performed, and the mean duration of clinical follow-up was 8 years (5-14 years). Regarding reconstructing the acetabular bone defects, autografts were used in 37 hips, allografts in 68 hips, and A-W glass ceramics in 2 hips. One hip exhibited radiological migration and no revision for aseptic loosening. The mean Merle d'Aubigné Clinical Score improved from 7.5 points (4-12 points) preoperatively to 10.9 points (9-18 points) at the last follow-up. The Kaplan-Meier survival rate for radiological migration of primary and revised THAs at 10 years was 100% and 97% (95% confidence interval: 96%-100%), respectively. Bone remodeling was evaluated using the radiological demarcation at the bone-to-bone interface, and an improvement of 100% in primary THAs and 94% in revised THAs was observed. For massive bone defects, acetabular reconstruction using the KT plate with a structural bone grafting can yield successful results. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Cross-cultural adaptation and validation of the Turkish version of Oxford hip score.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Hazar, Zeynep; Yüksel, İnci; Atilla, Bülent

    2015-06-01

    The purpose of this study was to translate the Oxford hip score (OHS) into Turkish and to evaluate the psychometric properties by testing the internal consistency, reproducibility, construct validity, and responsiveness in patients with hip osteoarthritis (OA). Oxford hip score was translated and culturally adapted according to the guidelines in the literature. Seventy patients (mean age 61.45 ± 9.29 years) with hip osteoarthritis participated in the study. Patients completed the Turkish Oxford hip score (OHS-TR), the Short-Form 36 (SF-36), and Western Ontario and McMaster Universities Index (WOMAC). Internal consistency was tested using Cronbach's α coefficient. Patients completed OHS-TR questionnaire twice in 7 days for determining the reproducibility. Correlation between the total results of both tests was determined by the Pearson correlation coefficient and intraclass correlation coefficient (ICC). Validity was assessed by calculating the Pearson correlation coefficient between the OHS-TR and WOMAC and SF-36 scores. Floor and ceiling effects were analyzed. The internal consistency was high (Cronbach's α 0.93). The construct validity showed a significant correlation between the OHS-TR and WOMAC and related SF-36 domains (p < 0.001). The ICC's ranged between 0.80 and 0.99. There was no floor or ceiling effect in total OHS-TR score. The OHS-TR questionnaire is valid, reliable, and responsive for the Turkish-speaking patients with hip OA.

  14. Prevalence and severity of hip and groin pain in sub-elite male football: a cross-sectional cohort study of 695 players.

    PubMed

    Thorborg, K; Rathleff, M S; Petersen, P; Branci, S; Hölmich, P

    2017-01-01

    The purpose of this study was twofold: (a) to investigate the prevalence of hip and groin pain in sub-elite male adult football in Denmark and (b) to explore the association between prevalence and duration of hip and groin pain in the previous season with the Copenhagen Hip and Groin Outcome Score (HAGOS) in the beginning of the new season. In total 695 respondents from 40 teams (Division 1-4) were included. Players completed in the beginning of the new season (July-Sept 2011) a self-reported paper questionnaire on hip and/or groin pain during the previous season and HAGOS. In total 49% (95% CI: 45-52%) reported hip and/or groin pain during the previous season. Of these, 31% (95% CI: 26-36%) reported pain for >6 weeks. Players with the longest duration of pain during the previous season had the lowest HAGOS scores, when assessed at the beginning of the new season, P < 0.001. This study documents that half of sub-elite male adult football players report pain in the hip and/or groin during a football season. The football players with the longest duration of pain in previous season displayed the lowest HAGOS scores in the beginning of the new season. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Analysis of the kinematics of different hip simulators used to study wear of candidate materials for the articulation of total hip arthroplasties.

    PubMed

    Ramamurti, B S; Estok, D M; Jasty, M; Harris, W H

    1998-05-01

    We developed an analytical technique to determine the paths traced by specific points on the femoral head against the acetabulum in the human hip joint during gait. The purpose of the study was to apply this technique to the mechanical hip simulators chosen to conduct wear tests on polymeric acetabular liners used in total hip replacements. These simulators differ from one another in the type of motion produced, apart from other variables such as type of lubricant and head position. Due to the variation in the kinematics between the machines, the paths traced by the points on the femoral head against the acetabular liner ranged from simple linear traces to figure-8 loops and quasi-elliptical paths during a single simulator cycle. The distances traveled by these points during the same period also varied appreciably among the different hip simulator designs. These results are important when combined with other studies that have shown that kinematics can play an important role in the outcome of in vitro wear experiments. The kinematic differences quantified in this study can partially explain the substantial differences in wear data reported from different simulator designs and also underscore the usefulness of the technique described in this study in judging the results from different hip simulator experiments.

  16. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    PubMed

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  17. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    PubMed Central

    2011-01-01

    Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm) and increased offset (44 mm) were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb). Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses), altering anteversion played a lesser role (5%). Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved. PMID:21569522

  18. Adventure sports and sexual freedom hip replacement: the tripolar hip.

    PubMed

    Pritchett, James W

    2018-01-01

    Certain athletic activities and lifestyles require a completely stable and very mobile hip. Total hip replacement with a natural femoral head size and two mobile-bearing surfaces (i.e., a "tripolar" prosthesis) is the most stable prosthesis. Elegant design and wear-resistant bearing surfaces are the keys to long-term implant survivorship. The hypothesis is that a ceramic-coated tripolar prosthesis using highly cross-linked polyethylene can provide full function and complete stability with low wear. This study sought to determine: (1) patient-reported outcomes, (2) functional outcomes, (3) implant survivorship and complications, and (4) postoperative sexual limitations. Between 1998 and 2011, the author performed 160 primary total hip replacements using tripolar prostheses in patients participating in adventure sports and other physically demanding activities. The institutional review board approved this study. The inclusion criteria were patients who needed unrestricted activity and who were not candidates for or did not choose hip resurfacing. Patients were followed every second year and assessed with radiographs, Harris Hip Score, WOMAC, SF-12, and UCLA functional outcome scores. Patients were asked about symptoms of instability and satisfaction with their hip replacement. Patients were asked both preoperatively and 2 years postoperatively four questions about their sexual activity. Mean follow-up was 11 years. At 2 years' postoperatively, 98% of patients reported their satisfaction as excellent or good and 99% were not limited for sexual activity following surgery. Seventy-four percent of patients reported they were recovered within 6 weeks of surgery. There were no dislocations. There were three revision procedures for implant loosening, infection, and periprosthetic fracture, but there were no failures of the tripolar articulation. The mean postoperative UCLA score was the highly athletic score of 8. There were no signs of osteolysis, wear, or metal sensitivity reactions. The range of motion achieved, sexual, and functional outcomes were higher than with other types of total hip replacement. This ceramic-coated tripolar prosthesis using highly cross-linked polyethylene provides full function, complete stability, and low wear to younger, active patients, thus confirming the hypothesis and clinical relevance.

  19. Retrospective Analysis for Genetic Improvement of Hip Joints of Cohort Labrador Retrievers in the United States: 1970–2007

    PubMed Central

    Lust, George; Zhu, Lan; Zhang, Zhiwu; Todhunter, Rory J.

    2010-01-01

    Background Canine Hip Dysplasia (CHD) is a common inherited disease that affects dog wellbeing and causes a heavy financial and emotional burden to dog owners and breeders due to secondary hip osteoarthritis. The Orthopedic Foundation for Animals (OFA) initiated a program in the 1960's to radiograph hip and elbow joints and release the OFA scores to the public for breeding dogs against CHD. Over last four decades, more than one million radiographic scores have been released. Methodology/Principal Findings The pedigrees in the OFA database consisted of 258,851 Labrador retrievers, the major breed scored by the OFA (25% of total records). Of these, 154,352 dogs had an OFA hip score reported between 1970 and 2007. The rest of the dogs (104,499) were the ancestors of the 154,352 dogs to link the pedigree relationships. The OFA hip score is based on a 7-point scale with the best ranked as 1 (excellent) and the worst hip dysplasia as 7. A mixed linear model was used to estimate the effects of age, sex, and test year period and to predict the breeding value for each dog. Additive genetic and residual variances were estimated using the average information restricted maximum likelihood procedure. The analysis also provided an inbreeding coefficient for each dog. The hip scores averaged 1.93 (±SD = 0.59) and the heritability was 0.21. A steady genetic improvement has accrued over the four decades. The breeding values decreased (improved) linearly. By the end of 2005, the total genetic improvement was 0.1 units, which is equivalent to 17% of the total phenotypic standard deviation. Conclusion/Significance A steady genetic improvement has been achieved through the selection based on the raw phenotype released by the OFA. As the heritability of the hip score was on the low end (0.21) of reported ranges, we propose that selection based on breeding values will result in more rapid genetic improvement than breeding based on phenotypic selection alone. PMID:20195372

  20. Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.

    PubMed

    Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V

    2017-08-01

    Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important part of the pre-operative discussion.

  1. Sagittal plane gait characteristics in hip osteoarthritis patients with mild to moderate symptoms compared to healthy controls: a cross-sectional study.

    PubMed

    Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Risberg, May Arna

    2012-12-20

    Existent biomechanical studies on hip osteoarthritic gait have primarily focused on the end stage of disease. Consequently, there is no clear consensus on which specific gait parameters are of most relevance for hip osteoarthritis patients with mild to moderate symptoms. The purpose of this study was to explore sagittal plane gait characteristics during the stance phase of gait in hip osteoarthritis patients not eligible for hip replacement surgery. First, compared to healthy controls, and second, when categorized into two subgroups of radiographic severity defined from a minimal joint space of ≤/>2 mm. Sagittal plane kinematics and kinetics of the hip, knee and ankle joint were calculated for total joint excursion throughout the stance phase, as well as from the specific events initial contact, midstance, peak hip extension and toe-off following 3D gait analysis. In addition, the Western Ontario and McMaster Universities Osteoarthritis Index, passive hip range of motion, and isokinetic muscle strength of hip and knee flexion and extension were included as secondary outcomes. Data were checked for normality and differences evaluated with the independent Student's t-test, Welch's t-test and the independent Mann-Whitney U-test. A binary logistic regression model was used in order to control for velocity in key variables. Fourty-eight hip osteoarthritis patients and 22 controls were included in the final material. The patients walked significantly slower than the controls (p=0.002), revealed significantly reduced joint excursions of the hip (p<0.001) and knee (p=0.011), and a reduced hip flexion moment at midstance and peak hip extension (p<0.001). Differences were primarily manifested during the latter 50% of stance, and were persistent when controlling for velocity. Subgroup analyses of patients with minimal joint space ≤/>2 mm suggested that the observed deviations were more pronounced in patients with greater radiographic severity. The biomechanical differences were, however, not reflected in self-reported symptoms or function. Reduced gait velocity, reduced sagittal plane joint excursion, and a reduced hip flexion moment in the late stance phase of gait were found to be evident already in hip osteoarthritis patients with mild to moderate symptoms, not eligible for total hip replacement. Consequently, these variables should be considered as key features in studies regarding hip osteoarthritic gait at all stages of disease. Subgroup analyses of patients with different levels of radiographic OA further generated the hypothesis that the observed characteristics were more pronounced in patients with a minimal joint space ≤2 mm.

  2. Histopathology of femoral head donations: a retrospective review of 6161 cases.

    PubMed

    Mackie, Katherine E; Zhou, Ziqiang; Robbins, Peter; Bulsara, Max; Zheng, Ming H

    2011-08-17

    Although total hip arthroplasty is one of the most common orthopaedic surgical procedures, it remains unclear whether histopathological examination of the excised femoral head adds to the quality of patient care. We propose that assessment of femoral heads resected during total hip arthroplasty and donated for allograft use may provide a profile of femoral head pathology that benefits total hip arthroplasty patients and bone donors. We retrospectively analyzed the histological findings reported for 6161 femoral heads donated for allograft use between 1993 and 2006. Specimens obtained during total hip arthroplasty and specimens donated at death were reviewed. Follow-up investigations that resulted from abnormal histopathological findings were also reviewed. The Western Australian Cancer Registry was used to determine whether patients with a suspected neoplasm were subsequently diagnosed with such a disease. A retrospective review of the histopathological findings was conducted to evaluate and reclassify all previous observations of abnormalities. One hundred and five femoral heads demonstrated abnormal or reactive histopathological features not reported prior to surgery and were rejected for allograft use. A reactive lymphocytic infiltrate, most likely due to osteoarthritis, was the most commonly identified feature (forty-five cases). Other features observed in twenty-seven cases were also most likely due to the presence of severe osteoarthritis. Ten femoral heads demonstrated plasmacytosis, which may have been related to osteoarthritis. Two patients were diagnosed with Paget's disease, and two, with rheumatoid arthritis. Nineteen patients had a suspected neoplasm. Of these nineteen, eight cases of non-Hodgkin's lymphoma or chronic lymphocytic leukemia and one case of myelodysplastic syndrome were confirmed on further investigation. One subsequently confirmed malignancy was detected per 770 femoral heads examined. Our findings indicate that, even with a detailed medical history and careful physical examination, clinically important diseases including neoplasms and Paget's disease are observed in patients diagnosed with osteoarthritis prior to total hip arthroplasty. Histological examination plays an integral role in quality assurance in femoral head banking, and it also represents a possible early diagnostic test for bone and bone-marrow-related diseases in patients undergoing total hip arthroplasty.

  3. Recognizing anterior metaphyseal femoral bone loss during uncemented total hip arthroplasty: the skylight sign.

    PubMed

    Harwin, Steven F

    2007-03-01

    During preparation for uncemented femoral arthroplasty, a phenomenon has been observed that indicates thinning of anterior metaphyseal bone to a critical level. Light can be seen from within the canal passing through the anterior cortex. This skylight sign alerts the surgeon that a cortical defect or fracture can occur on reaming, broaching, or component insertion. In 420 consecutive arthroplasties, a skylight sign was noted in 97 (23%) hips. In 5 of those hips an oval cortical defect was created and in 3 hips a fracture occurred during broaching or insertion. Loosening developed in 1 hip with fracture. No fractures or defects occurred in hips without a skylight sign. If a skylight sign is present, the femur is at risk and preventive measures should be taken.

  4. Comparing return to sport activities after short metaphyseal femoral arthroplasty with resurfacing and big femoral head arthroplasties.

    PubMed

    Karampinas, Panagiotis K; Papadelis, Eustratios G; Vlamis, John A; Basiliadis, Hlias; Pneumaticos, Spiros G

    2017-07-01

    Young patients feel that maintaining sport activities after total hip arthroplasty constitutes an important part of their quality of life. The majority of hip surgeons allow patients to return to low-impact activities, but significant caution is advised to taking part in high-impact activities. The purpose of this study is to compare and evaluate the post-operative return to daily living habits and sport activities following short-metaphyseal hip and high functional total hip arthroplasties (resurfacing and big femoral head arthroplasties). In a study design, 48 patients (55 hips) were enrolled in three different comparative groups, one with the short-metaphyseal arthroplasties, a second with high functional resurfacing arthroplasties and a third of big femoral head arthroplasties. Each patient experienced a clinical examination and evaluated with Harris Hip Score, WOMAC, Sf-36, UCLA activity score, satisfaction VAS, anteroposterior and lateral X-rays of the hip and were followed in an outpatient setting for 2 years. Statistical analysis revealed no notable differences between the three groups regarding their demographic data however significant differences have been found between preoperative and postoperative clinical scores of each group. Also, we fail to reveal any significant differences when comparing data of all three groups at the final 2 years postoperative control regarding their clinical scores. The overall outcome of all three groups was similar, all the patients were satisfied and returned to previous level of sport activities. Short metaphyseal hip arthroplasties in young patients intending to return to previous and even high impact sport activities, similar to high functional resurfacing, big femoral head arthroplasties. Short stems with hard on hard bearing surfaces might become an alternative to standard stems and hip resurfacing.

  5. Autonomy, Choice, Patient-Centered Care, and Hip Protectors: The Experience of Residents and Staff in Long-Term Care

    PubMed Central

    Sims-Gould, Joanie; McKay, Heather A.; Feldman, Fabio; Scott, Victoria; Robinovitch, Stephen N.

    2013-01-01

    The purpose of this study was to examine long-term care (LTC) resident and staff perceptions on the decision to use hip protectors and identify the factors that influence attitudes toward hip protector use. Staff (N = 39) and residents (N = 27) at two residential care facilities in British Columbia, Canada were invited to participate in focus groups on fall prevention and hip protector use. A total of 11 focus groups were conducted. Using framework analysis results show that residents and staff shared concerns on aesthetic and comfort issues with hip protectors. Residents also generally felt they did not need, or want to use, hip protectors. However, they also had desire to be cooperative within the LTC environment. Staff underscored their role in advocating for hip protector use and their desire to protect residents from harm. Practice considerations for facilities wishing to promote hip protectors within a patient centered framework are highlighted. PMID:24652886

  6. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 conserve plus.

    PubMed

    Amstutz, Harlan C; Le Duff, Michel J

    2008-09-01

    Hip resurfacing is currently the fastest growing hip procedure worldwide. We reviewed 1000 hips in 838 patients who received a Conserve Plus (Wright Medical Technology, Inc., Arlington, Tenn) resurfacing at a single institution. The mean age of the patients was 50.0 years with 74.7% male. The hips were resurfaced irrespective of femoral defect size or etiology. The mean follow-up was 5.6 years (range, 1.1-11.0 years). All clinical scores improved significantly (P < .05). There was no acetabular component loosening. Ten were converted to total hip arthroplasty for femoral neck fracture, 20 for femoral loosening, 2 for sepsis, and 1 for recurrent subluxations. The 5-year survivorship was 95.2% with no failures in hips implanted since 2002. Short-term failures can be prevented. First-generation surgical technique and a low body mass index were the most important risk factors for the procedure. Improvements in bone preparation significantly increased prosthetic survival in hips with risk factors for failure.

  7. Hip arthroscopy using the lateral approach.

    PubMed

    Glick, J M

    1988-01-01

    The benefits of hip arthroscopy are apparent. It produces little postoperative morbidity and can be performed on an outpatient basis. The prompt recovery from the operation is also beneficial, particularly for elderly patients. Distraction of the hip by traction on a fracture table is necessary. Suggested indications for this procedure include synovectomy and synovial biopsy; removal of loose bodies; removal of debris after a closed reduction of a fracture-dislocation; evaluation and treatment of osteochondritis dissecans; evaluation for arthroplasty; and unresolved hip pain. Whether the lateral approach is useful in the following situations is yet to be explored: (1) Evaluation of pediatric conditions such as Legg-Perthes disease and congenital dislocated hip; (2) treatment of localized infection; (3) removal of entrapped methylmethacrylate in total hip replacement; and (4) reducing and fixating an acetabular fracture (M. Brennan, oral communication, April 6, 1987). Arthroscopy of the hip joint by the lateral approach is a valuable addition to the evaluation and treatment of hip disorders.

  8. Outcome of total hip arthroplasty for avascular necrosis of the femoral head in systemic lupus erythematosus.

    PubMed

    Woo, Min Su; Kang, Joon Soon; Moon, Kyoung Ho

    2014-12-01

    This study evaluated the result of total hip arthroplasty (THA) for avascular necrosis of the femur head (AVNFH) in systemic lupus erythematosus (SLE) patients. Nineteen THAs were performed on 13 patients with SLE. The results of these patients were compared with the results of the control group (19 patients) who had THR due to AVNFH with none-SLE conditions. The Harris hip score increased from a preoperative average of 65.3 points to 94.9 at the most recent follow-up. In the control group, the mean HHS was 67.2 preoperatively and 96.1 postoperatively at the last follow-up. No significant difference was found between SLE patients and non-SLE patients who underwent hip arthroplasty. In conclusion, THA is an acceptable treatment for achieving functional improvement in patients who had SLE and AVNFH. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Unconstrained tripolar implants for primary total hip arthroplasty in patients at risk for dislocation.

    PubMed

    Guyen, Olivier; Pibarot, Vincent; Vaz, Gualter; Chevillotte, Christophe; Carret, Jean-Paul; Bejui-Hugues, Jacques

    2007-09-01

    We performed a retrospective study on 167 primary total hip arthroplasty (THA) procedures in 163 patients at high risk for instability to assess the reliability of unconstrained tripolar implants (press-fit outer metal shell articulating a bipolar polyethylene component) in preventing dislocations. Eighty-four percent of the patients had at least 2 risk factors for dislocation. The mean follow-up length was 40.2 months. No dislocation was observed. Harris hip scores improved significantly. Six hips were revised, and no aseptic loosening of the cup was observed. The tripolar implant was extremely successful in achieving stability. However, because of the current lack of data documenting polyethylene wear at additional bearing, the routine use of tripolar implants in primary THA is discouraged and should be considered at the present time only for selected patients at high risk for dislocation and with limited activities.

  10. Analysis of lumbar spine and hip motion during forward bending in subjects with and without a history of low back pain.

    PubMed

    Esola, M A; McClure, P W; Fitzgerald, G K; Siegler, S

    1996-01-01

    This study analyzed two groups of subjects during forward bending. Group 1 (n = 20) contained subjects with a history of low back pain and Group 2 (n = 21) included subjects without a history of low back pain. The purposes of this study were to establish the amount and pattern of lumbar spine and hip motion during forward bending, and determine differences in motion in subjects with and without a history of low back pain. Reported values for lumbar spine motion during forward bending vary from 23.9 degrees to 60 degrees and hip motion during forward bending ranges from 26 degrees to 66 degrees. There has been no direct study of both lumbar spine and hip motion during forward bending in subjects with and without a history of low back pain to establish differences in total amounts or pattern of lumbar spine and hip motion during forward bending. A three-dimensional optoelectric motion analysis system was used to measure the amount and velocity of lumbar spine and hip motion during forward bending. Each subject performed three trials of forward bending that were averaged and used for statistical analysis. Hamstring flexibility was also assessed by two clinical tests, the passive straight leg raising and active knee extension tests. Mean total forward bending for all subjects was 111 degrees: 41.6 degrees from the lumbar spine and 69.4 degrees from the hips. There were no group differences for total amounts of lumbar spine and hip motion or velocity during forward bending. The pattern of motion was described by calculating lumbar-to-hip flexion ratios for early (0-30 degrees), middle (30-60 degrees), and late (60-90 degrees) forward bending. For all subjects, mean lumbar-to-hip ratios for early, middle, and late forward bending were 1.9, 0.9, and 0.4, respectively. Therefore, the lumbar spine had a greater contribution to early forward bending, the lumbar spine and hips contributed almost equally to middle forward bending, and the hips had a greater contribution to late forward bending. A t test revealed a difference between groups for the pattern of motion. Group 1 tended to move more at their lumbar spine during early forward bending and had a significantly lower lumbar-to-hip flexion ratio during middle forward bending (P < 0.01). Hamstring flexibility was strongly correlated to motion in subjects with a history of low back pain, but not in healthy subjects. The results provide quantitative data to guide clinical assessment of forward bending motion. Results also suggest that although people with a history of low back pain have amounts of lumbar spine and hip motion during forward bending similar to those of healthy subjects, the pattern of motion is different. It may be desirable to teach patients with a history of low back pain to use more hip motion during early forward bending, and hamstring stretching may be helpful for encouraging earlier hip motion.

  11. Effect of Body Mass Index on Digital Templating for Total Hip Arthroplasty.

    PubMed

    Sershon, Robert A; Diaz, Alejandro; Bohl, Daniel D; Levine, Brett R

    2017-03-01

    Digital templating is becoming more prevalent in orthopedics. Recent investigations report high accuracy using digital templating in total hip arthroplasty (THA); however, the effect of body mass index (BMI) on templating accuracy is not well described. Digital radiographs of 603 consecutive patients (645 hips) undergoing primary THA by a single surgeon were digitally templated using OrthoView (Jacksonville, FL). A 25-mm metallic sphere was used as a calibration marker. Preoperative digital hip templates were compared with the final implant size. Hips were stratified into groups based on BMI: BMI <30 (315), BMI 30-35 (132), BMI 35-40 (97), and BMI >40 (101). Accuracy between templating and final size did not vary by BMI for acetabular or femoral components. Digital templating was within 2 sizes of the final acetabular and femoral implants in 99.1% and 97.1% of cases, respectively. Digital templating is an effective means of predicting the final size of THA components. BMI does not appear to play a major role in altering THA digital templating accuracy. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Clinical Results of Total Hip Arthroplasty in Two Patients with Charcot Hip Joints due to Congenital Insensivity to Pain with Anhydrosis

    PubMed Central

    Inoue, Daisuke; Kajino, Yoshitomo; Taga, Tadashi; Yamamoto, Takashi; Takagi, Tomoharu

    2018-01-01

    Traditionally, Charcot arthropathy has been considered an absolute contraindication for total hip arthroplasty (THA). However, some recent reports have shown that good short- to mid-term results can be achieved by improving the durability of the implant. This paper reports the mid- to long-term results of THA in two patients with Charcot hip joints caused by congenital insensivity to pain with anhydrosis. Both patients suffered multiple posterior dislocations in the six months immediately following surgery. However, with the continuous use of a hard abduction brace, one patient was eventually able to walk with a lofstrand cane and the other with the use of one crutch. Although one patient experienced a dislocation five years after surgery, X-rays taken after nine years and five years, respectively, revealed no clinical signs of implant loosening. We conclude that, with careful planning and appropriate precautions, THA may be a viable treatment option for Charcot hip joints caused by congenital insensivity to pain with anhydrosis. PMID:29666733

  13. Properties of the patient administered questionnaires: new scales measuring physical and psychological symptoms of hip and knee disorders.

    PubMed

    Mancuso, Carol A; Ranawat, Amar S; Meftah, Morteza; Koob, Trevor W; Ranawat, Chitranjan S

    2012-04-01

    The Patient Administered Questionnaires (PAQ) incorporate physical and psychological symptoms into one scale and permit more comprehensive self-reports for hip and knee disorders. We tested the psychometric properties of the PAQ-Hip and PAQ-Knee. Correlations between baseline PAQ-Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) were .39 to .72 (n = 102), .39 to .69 for score change (n = 68 post-total hip arthroplasty), and most κ values > .60 (n = 50). Correlations between baseline PAQ-Knee and WOMAC were .35 to .64 (n = 100), .62 to .79 for score change (n = 43 post-total knee arthroplasty), and most κ values >.60 (n = 51). For both scales, effect sizes were higher than for the WOMAC, and there was modest correlation between physical and psychological questions, indicating these concepts are not completely interchangeable. Thus, the PAQ scales have strong psychometric properties and are unique compared with existing scales by including physical and psychological symptoms. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. [Total hip arthroplasty in post-dysplastic hip arthritis. Can type and position of the acetabular component influence longevity of the prosthesis?].

    PubMed

    Fousek, J; Indráková, P

    2007-02-01

    The aim of the study was a retrospective evaluation of our patients with post-dysplastic hips treated by cemented or non-cemented total hip arthroplasty (THA) in order to ascertain which type and position of the acetabular component was most effective. In the years 1999-2002, 111 THA procedures were performed in 93 patients, 76 women and 17 men, with post-dysplastic hip arthritis. The average age of the patients at the time of implantation was 52.6 years. On the basis of pre-operative radiographic findings, the patients' conditions were evaluated using the Hartofilakidis classification into three disease categories: dysplasia, low dislocation and high dislocation, and the patients were placed in two groups. Group 1 included 78 patients, and group 2 comprised 26 patients. None of our patients was classified as having high dislocation. Thirty-nine of these patients had previously undergone surgery for dysplastic hips. A total of 104 THAs were evaluated, because radiographic data was incomplete in seven cases. In addition to X-ray findings, the prosthesis type (cemented, hybrid, non-cemented), post-operative complications and signs of loosening were included in the evaluation. Clinical outcomes were assessed by the Harris score. The follow-up terminating on 31st December 2005 was 67 months on the average. In group 1 patients, the average Harris score increased from 38.6 to 80.3 points and in group 2 patients from 35.5 to 84.9 points, mostly with excellent and good results. In 72.1 % of the hips, a press-fit acetabular component was implanted. In 55.8 % of the cases, the acetabular component was implanted off the anatomical center of rotation, into the high hip center, with the range from 9 to 20 mm and an average of 15 mm. The average limb lengthening was 2.5 cm, ranging from 1.0 to 3.5 cm. Our results show that it is more effective to use non-cemented THA for post-dysplastic hips. The implantation of a noncemented acetabular component into the high center provides better covering of the cup with solid bone, without the necessity of cotyloplasty or structural graft use. Also, it does not markedly affect hip function or patients' subjective feelings.

  15. Posterior hip dislocation in a non-professional football player: a case report and review of the literature.

    PubMed

    Bakalakos, Matthaios; Benetos, Ioannis S; Rozis, Meletios; Vlamis, John; Pneumaticos, Spiros

    2018-06-02

    The majority of injuries during a football game are contusions, sprains and/or strains in the thigh, knee and ankle. Hip dislocations account for 2-5% of total hip dislocations, and they can be posterior or anterior. Major complications of traumatic hip dislocation include avascular necrosis of femoral head, secondary osteoarthritis, sciatic nerve injury and heterotopic ossification. On the occasion of a case of a 33-year-old football player, who suffered a posterior hip dislocation, associated with a posterior wall fracture of the acetabulum, while playing football, we review the literature and analyze the various mechanisms of injury, the possible complications and the management including surgery and rehabilitation.

  16. [Influence of Comorbidities on Revision Rate within the First Year after Primary Total Hip Arthroplasty].

    PubMed

    Nesslage, Roman; Radtke, Kerstin; Hohloch, Lisa; Flörkemeier, Thilo; Windhagen, Henning; Lewinski, Gabriela von

    2017-04-01

    Background Total hip arthroplasty (THA) is very frequently performed. Despite low complication rates, revisions play an important clinical and economical role. The aim of this study was to identify comorbid diseases of patients undergoing primary THA and their potential influence on the survival of hip replacements. Patients/Material and Methods A total of 867 patients were included in this retrospective study. All revisions were reviewed that took place at our hospital within one year of primary implantation of THA. Comorbid diseases were detected by administrative data, using the Elixhauser definition, which includes thirty diseases. The Cox regression model and Fisher's exact test were used to examine correlations between comorbidities and risk of revision. Results 41 Patients required re-operation within the first year of surgery. The presence of one or more of the analysed comorbidities was associated with a greater risk of revision. Deficiency anemia, obesity, drug abuse, alcohol abuse, fluid and electrolyte disorders and peripheral vascular disorders were associated with increased risk of revision (p < 0.05 for all comparisons). The total number of comorbidities and specific comorbid diseases was independently associated with an increased risk of re-operation within the first year of total hip arthroplasty. This information could be helpful in pre- and post-operative risk adjustment and patient selection. Georg Thieme Verlag KG Stuttgart · New York.

  17. Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty.

    PubMed

    Lecerf, G; Fessy, M H; Philippot, R; Massin, P; Giraud, F; Flecher, X; Girard, J; Mertl, P; Marchetti, E; Stindel, E

    2009-05-01

    BACKGROUND OBJECTIVE: Femoral offset is supposed to influence the results of hip replacement but little is known about the accurate method of measure and the true effect of offset modifications. This article is a collection of independent anatomic, radiological and clinical works, which purpose is to assess knowledge of the implications of femoral offset for preoperative templating and total hip arthroplasty. There is a strong correlation between femoral offset, abductors lever arm and hip abductor strength. Hip lateralization is independent of the femoral endomedullary characteristics. The abductors lever arm is highly correlated to the gluteus medius activation angle. There were correlations between femoral offset and endomedullary shape. The hip center was high and medial for stovepipe metaphysis while it was lower and lateralized for champagne - flute upper femur. A study was performed to compare the femoral offset measured by X-ray and CT-scan in 50 patients, demonstrated that plain radiography underestimates offset measurement. The 2D templating cannot appreciate the rotation of the lower limb. Taking into account the horizontal plane is essential to obtain proper 3D planning of the femoral offset. A randomized study was designed to compare femoral offset measurements after hip resurfacing and total hip arthroplasty. This study underlined hip resurfacing reduced the femoral offset, while hip replacement increased offset. However, the reduction of femoral offset after hip resurfacing does not affect the function. A pilot study was designed to assess the results of 120 hip arthroplasties with a modular femoral neck. This study showed that the use of a modular collar ensures an easier restoration of the femoral offset. A cohort of high offset stems (Lubinus 117 degrees) was retrospectively assessed. The survival rate was slightly lower that the standard design reported in the Swedish register. Finally, the measurement of offset and leg length was assessed with the help of computer assistance. The software changed the initial schedule (obtained by templating) in 29%. Therefore, femoral offset restoration is essential to improve function and longevity of hip arthroplasty. CT-scan is more accurate than plain radiography to assess femoral offset. Hip resurfacing decreases offset without effect on function. Modular neck and computer assistance may improve intraoperative calculation and reproduction of femoral offset. Increasing offset with a standard cemented design may decrease long-term fixation. Level IV: Retrospective or historical series.

  18. Corrosion on the acetabular liner taper from retrieved modular metal-on-metal total hip replacements.

    PubMed

    Gascoyne, Trevor C; Dyrkacz, Richard M; Turgeon, Thomas R; Burnell, Colin D; Wyss, Urs P; Brandt, Jan-M

    2014-10-01

    Eight retrieved metal-on-metal total hip replacements displayed corrosion damage along the cobalt-chromium alloy liner taper junction with the Ti alloy acetabular shell. Scanning electron microscopy indicated the primary mechanism of corrosion to be grain boundary and associated crevice corrosion, which was likely accelerated through mechanical micromotion and galvanic corrosion resulting from dissimilar alloys. Coordinate measurements revealed up to 4.3mm(3) of the cobalt-chromium alloy taper surface was removed due to corrosion, which is comparable to previous reports of corrosion damage on head-neck tapers. The acetabular liner-shell taper appears to be an additional source of metal corrosion products in modular total hip replacements. Patients with these prostheses should be closely monitored for signs of adverse reaction towards corrosion by-products. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Total hip arthroplasty using a short-stem prosthesis: restoration of hip anatomy.

    PubMed

    Amenabar, Tomas; Marimuthu, Kanniraj; Hawdon, Gabrielle; Gildone, Alessandro; McMahon, Stephen

    2015-04-01

    To evaluate hip parameters such as vertical centre of rotation (VCR), horizontal centre of rotation (HCR), femoral offset, and leg length after total hip arthroplasty (THA) using the Nanos short-stem prosthesis. Medical records of 73 men and 74 women aged 25 to 92 (mean, 63) years who underwent THA using the Nanos short-stem prosthesis by a single surgeon were reviewed. Prior to the surgery, the optimal cup and stem size, head length, and level of the neck osteotomy were determined using radiographs. Intra-operatively, the leg length and femoral offset were checked, and the level of neck resection and head length were adjusted. VCR, HCR, femoral offset, and leg length of the operated and contralateral sides were compared. Functional outcomes were assessed using the Harris Hip Score (HHS). Compared with the normal contralateral hips, the operated hips had a mean increase of 0.4 mm in VCR (p=0.032), a mean decrease of 1.4 mm in HCR (p=0.027), a mean increase of 0.6 mm in femoral offset (p=0.043), and a mean increase of 0.36 mm in leg length (p=0.035). For these respective parameters, the difference between the normal contralateral side and the operated side was within 5 mm in 89%, 80%, 71%, and 96% of patients. The HHS improved from a mean of 53 to 91 at one year (p<0.001). THA using the Nanos short-stem prosthesis enabled restoration of hip anatomy (VCR, HCR, femoral offset, and leg length).

  20. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    PubMed Central

    Ovesen, Ole; Brixen, Kim; Varmarken, Jens-Erik; Overgaard, SØren

    2010-01-01

    Background and purpose Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. Method We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15° internal, neutral, and 15° external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. Results When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15° or 30°, the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. Interpretation If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled. PMID:20367420

  1. Posterosuperior Placement of a Standard-Sized Cup at the True Acetabulum in Acetabular Reconstruction of Developmental Dysplasia of the Hip With High Dislocation.

    PubMed

    Xu, Jiawei; Xu, Chen; Mao, Yuanqing; Zhang, Jincheng; Li, Huiwu; Zhu, Zhenan

    2016-06-01

    We sought to evaluate posterosuperior placement of the acetabular component at the true acetabulum during acetabular reconstruction in patients with Crowe type-IV developmental dysplasia of the hip. Using pelvic computed tomography and image processing, we developed a two-dimensional mapping technique to demonstrate the distribution of preoperative three-dimensional cup coverage at the true acetabulum, determined the postoperative location of the acetabular cup, and calculated postoperative three-dimensional coverage for 16 Crowe type-IV dysplastic hips in 14 patients with a mean age of 52 years (33-78 years) who underwent total hip arthroplasty. Mean follow-up was 6.3 years (5.5-7.3 years). On preoperative mapping, the maximum three-dimensional coverage using a 44-mm cup was 87.31% (77.36%-98.14%). Mapping enabled the successful replacement of 16 hips using a mean cup size of 44.13 mm (42-46 mm) with posterosuperior placement of the cup. Early weight-bearing and no prosthesis revision or loosening during follow-up were achieved in all patients. The postoperative two-dimensional coverage on anteroposterior radiographs and three-dimensional coverage were 96.15% (89.49%-100%) and 83.42% (71.81%-98.50%), respectively. This technique may improve long-term implant survival in patients with Crowe-IV developmental dysplasia of the hip undergoing total hip arthroplasty by allowing the use of durable bearings, increasing host bone coverage, ensuring initial stability, and restoring the normal hip center. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Mini Nutritional Assessment predicts gait status and mortality 6 months after hip fracture.

    PubMed

    Gumieiro, David N; Rafacho, Bruna P M; Gonçalves, Andrea F; Tanni, Suzana E; Azevedo, Paula S; Sakane, Daniel T; Carneiro, Carlos A S; Gaspardo, David; Zornoff, Leonardo A M; Pereira, Gilberto J C; Paiva, Sergio A R; Minicucci, Marcos F

    2013-05-01

    The aim of the present study was to evaluate the Mini Nutritional Assessment (MNA), the Nutritional Risk Screening (NRS) 2002 and the American Society of Anesthesiologists Physical Status Score (ASA) as predictors of gait status and mortality 6 months after hip fracture. A total of eighty-eight consecutive patients over the age of 65 years with hip fracture admitted to an orthopaedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, and the MNA, the NRS 2002 and the ASA were performed. Gait status and mortality were evaluated 6 months after hip fracture. Of the total patients, two were excluded because of pathological fractures. The remaining eighty-six patients (aged 80·2 (sd 7·3) years) were studied. Among these patients 76·7 % were female, 69·8 % walked with or without support and 12·8 % died 6 months after the fracture. In a multivariate analysis, only the MNA was associated with gait status 6 months after hip fracture (OR 0·773, 95 % CI 0·663, 0·901; P= 0·001). In the Cox regression model, only the MNA was associated with mortality 6 months after hip fracture (hazard ratio 0·869, 95 % CI 0·757, 0·998; P= 0·04). In conclusion, the MNA best predicts gait status and mortality 6 months after hip fracture. These results suggest that the MNA should be included in the clinical stratification of patients with hip fracture to identify and treat malnutrition in order to improve the outcomes.

  3. Accuracy of femoral templating in reproducing anatomical femoral offset in total hip replacement.

    PubMed

    Davies, H; Foote, J; Spencer, R F

    2007-01-01

    Restoration of hip biomechanics is a crucial component of successful total hip replacement. Preoperative templating is recommended to ensure that the size and orientation of implants is optimised. We studied how closely natural femoral offset could be reproduced using the manufacturers' templates for 10 femoral stems in common use in the UK. A series of 23 consecutive preoperative radiographs from patients who had undergone unilateral total hip replacement for unilateral osteoarthritis of the hip was employed. The change in offset between the templated position of the best-fitting template and the anatomical centre of the hip was measured. The templates were then ranked according to their ability to reproduce the normal anatomical offset. The most accurate was the CPS-Plus (Root Mean Square Error 2.0 mm) followed in rank order by: C stem (2.16), CPT (2.40), Exeter (3.23), Stanmore (3.28), Charnley (3.65), Corail (3.72), ABG II (4.30), Furlong HAC (5.08) and Furlong modular (7.14). A similar pattern of results was achieved when the standard error of variability of offset was analysed. We observed a wide variation in the ability of the femoral prosthesis templates to reproduce normal femoral offset. This variation was independent of the seniority of the observer. The templates of modern polished tapered stems with high modularity were best able to reproduce femoral offset. The current move towards digitisation of X-rays may offer manufacturers an opportunity to improve template designs in certain instances, and to develop appropriate computer software.

  4. The Effect of Vitamin A on Fracture Risk: A Meta-Analysis of Cohort Studies

    PubMed Central

    Zhang, Xinge; Zhang, Rui; Wang, Yueqiao; Yan, Hanyi; Wu, Yingru; Tan, Anran; Fu, Jialin; Shen, Ziqiong; Qin, Guiyu; Li, Rui; Chen, Guoxun

    2017-01-01

    This meta-analysis evaluated the influence of dietary intake and blood level of vitamin A (total vitamin A, retinol or β-carotene) on total and hip fracture risk. Cohort studies published before July 2017 were selected through English-language literature searches in several databases. Relative risk (RR) with corresponding 95% confidence interval (CI) was used to evaluate the risk. Heterogeneity was checked by Chi-square and I2 test. Sensitivity analysis and publication bias were also performed. For the association between retinol intake and total fracture risk, we performed subgroup analysis by sex, region, case ascertainment, education level, age at menopause and vitamin D intake. R software was used to complete all statistical analyses. A total of 319,077 participants over the age of 20 years were included. Higher dietary intake of retinol and total vitamin A may slightly decrease total fracture risk (RR with 95% CI: 0.95 (0.91, 1.00) and 0.94 (0.88, 0.99), respectively), and increase hip fracture risk (RR with 95% CI: 1.40 (1.02, 1.91) and 1.29 (1.06, 1.57), respectively). Lower blood level of retinol may slightly increase total fracture risk (RR with 95% CI: 1.11 (0.94, 1.30)) and hip fracture risk (RR with 95% CI: 1.27 (1.05, 1.53)). In addition, higher β-carotene intake was weakly associated with the increased risk of total fracture (RR with 95% CI: 1.07 (0.97, 1.17)). Our data suggest that vitamin A intake and level may differentially influence the risks of total and hip fractures. Clinical trials are warranted to confirm these results and assess the clinical applicability. PMID:28891953

  5. Mechanical Prophylaxis after Lower Extremity Total Joint Arthroplasty: A Review.

    PubMed

    Chughtai, Morad; Newman, Jared M; Solow, Max; Davidson, Iyooh U; Sodhi, Nipun; Gaal, Benjamin; Khlopas, Anton; Sultan, Assem A; Mont, Michael A

    2017-12-22

    Venous thromboembolism (VTE) is a serious complication that can occur after total hip and knee arthroplasty, and can potentially lead to significant morbidity and even mortality. While various modalities have been used to prevent VTE development, the medications can be associated with a number of adverse events. Therefore, mechanical prophylaxis with pumps and compressive devices has been used more frequently alone, or in combination, with medications. Therefore, the purpose of this study was to review the current literature on mechanical prophylaxis for VTEs after lower extremity total joint arthroplasty. Specifically, we reviewed mechanical prophylaxis after: 1) total hip arthroplasty and 2) total knee arthroplasty.

  6. Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty.

    PubMed

    Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray

    2015-03-01

    The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.

  7. Hip Arthroscopy Outcomes With Respect to Patient Acceptable Symptomatic State and Minimal Clinically Important Difference.

    PubMed

    Levy, David M; Kuhns, Benjamin D; Chahal, Jaskarndip; Philippon, Marc J; Kelly, Bryan T; Nho, Shane J

    2016-09-01

    To determine whether the hip arthroscopy literature to date has shown outcomes consistent with published patient acceptable symptomatic state (PASS) and minimal clinically important difference (MCID) estimates. All clinical investigations of hip arthroscopy using modified Harris Hip Score (mHHS) and/or Hip Outcome Score (HOS) outcomes with at least 1 year of follow-up were reviewed. Ninety-one studies (9,746 hips) were included for review. Eighty-one studies (9,317 hips) contained only primary hip arthroscopies and were the primary focus of this review. The remaining studies (429 hips) did not exclude patients with prior surgical history and were thus considered separately. Mean mHHS, HOS-ADL (Activities of Daily Living) and HOS-SS (Sports-Specific) scores were compared with previously published PASS and MCID values. After 31 ± 20 months, 5.8% of study populations required revision arthroscopy and 5.5% total hip arthroplasty. A total of 88%, 25%, and 30% of study populations met PASS for mHHS, HOS-ADL, and HOS-SS, respectively, and 97%, 90%, and 93% met MCID. On bivariate analysis, increasing age was associated with significantly worse postoperative mHHS (P < .01, R(2) = 0.14), HOS-SS (P = .05, R(2) = 0.12), and rates of reoperation (P = .02, R(2) = 0.08). Increasing body mass index was associated with significantly worse HOS-ADL (P = .02, R(2) = 0.35) and HOS-SS (P = .03, R(2) = 0.30). In this meta-analysis of 81 studies of primary hip arthroscopy, we have found that more than 90% of study populations meet MCID standards for the most commonly used patient-reported outcomes measures in hip arthroscopy literature, mHHS and HOS. Eighty-eight percent meet PASS standards for the mHHS, but PASS standards are far more difficult to achieve for HOS-ADL (25%) and HOS-SS (30%) subscales. Differences in psychometric properties of the mHHS and HOS likely account for the discrepancies in PASS. Level IV, systematic review of Level I to IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Dynamic long leg casting fixation for treating 12- to 18-month-old infants with developmental dysplasia of the hip.

    PubMed

    Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun

    2017-02-01

    Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.

  9. Quality Indicators for Quality of Care During Hospitalization for Vulnerable Elder Persons

    DTIC Science & Technology

    2004-08-01

    hip fracture as well as all abdominal, pelvic or lower extremity surgeries above the shin, except laparoscopic surgeries, and patients with prior...24 63. Williams MA, Campbell EB, Raynor WJ, Mlynarczyk SM, Ward SE. Reducing acute confusional states in elderly patients with hip fractures ...studies of patients receiving total hip replacements) but inferior to the acceptable regimens above. Pulmonary embolism, the sequelae of deep vein

  10. Static balance according to hip joint angle of unsupported leg during one-leg standing.

    PubMed

    Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob

    2017-05-01

    [Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.

  11. Efficacy of Kirschner-wires and tension band in hip arthroplasty for aged patients with unstable intertrochanteric osteoporotic fracture

    PubMed Central

    Zhang, Hua; Xu, Zhongwei; Zhou, Aiguo; Yan, Wenlong; Zhao, Pei; Huang, Xiao; Zhang, Jian

    2017-01-01

    Abstract The aim of this study was to evaluate the efficacy of supplementary fixation in hip arthroplasty with the use of Kirschner-wires and tension band for geriatric patients suffering unstable intertrochanteric osteoporotic fractures. A total of 103 patients aged more than 75 years were recruited. A bipolar or total hip replacement was performed with additional application of Kirschner-wires and tension band, and the participants were followed up for 2 to 11 years. Physical component summary (PCS), mental component summary (MCS), visual analog scale (VAS), and Harris hip score were utilized to evaluate patients’ hip pain and function, as well as the mental condition postoperatively after 1.5 months, 3 months, 6 months, 1 year, and annually thereafter until the latest follow-up in 2015. Patients showed a significant improvement in all scores between 1.5 months and 1 year (P < 0.001), with the good efficacy lasting at least until the 2-year follow-up. None of the patients showed dislocation, implant loosening, or nonunion of the fracture throughout the follow-up period. In conclusion, it was beneficial to treat unstable intertrochanteric osteoporotic fractures in aged patients with hip arthroplasty coupled with Kirschner-wires and tension band. PMID:28072698

  12. Patient-specific musculoskeletal modeling of the hip joint for preoperative planning of total hip arthroplasty: A validation study based on in vivo measurements

    PubMed Central

    Schick, Fabian; Asseln, Malte; Damm, Philipp; Radermacher, Klaus

    2018-01-01

    Validation of musculoskeletal models for application in preoperative planning is still a challenging task. Ideally, the simulation results of a patient-specific musculoskeletal model are compared to corresponding in vivo measurements. Currently, the only possibility to measure in vivo joint forces is to implant an instrumented prosthesis in patients undergoing a total joint replacement. In this study, a musculoskeletal model of the AnyBody Modeling System was adapted patient-specifically and validated against the in vivo hip joint force measurements of ten subjects performing one-leg stance and level walking. The impact of four model parameters was evaluated; hip joint width, muscle strength, muscle recruitment, and type of muscle model. The smallest difference between simulated and in vivo hip joint force was achieved by using the hip joint width measured in computed tomography images, a muscle strength of 90 N/cm2, a third order polynomial muscle recruitment, and a simple muscle model. This parameter combination reached mean deviations between simulation and in vivo measurement during the peak force phase of 12% ± 14% in magnitude and 11° ± 5° in orientation for one-leg stance and 8% ± 6% in magnitude and 10° ± 5° in orientation for level walking. PMID:29649235

  13. A Two Centre Study to Assess the Stability and Long-term Performance of the C-Stem™ AMT in a Total Primary Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Rheumatoid Arthritis; Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  14. A Randomised Single Centre Study to Compare the Long-term Wear Characteristics of Marathon™ and Enduron™ Polyethylene Cup Liners in Primary Total Hip Replacement

    ClinicalTrials.gov

    2017-06-23

    Osteoarthritis; Post-traumatic Arthritis; Collagen Disorders; Avascular Necrosis; Traumatic Femoral Fractures; Nonunion of Femoral Fractures; Congenital Hip Dysplasia; Slipped Capital Femoral Epiphysis

  15. Ten-Year Outcome of Serum Metal Ion Levels After Primary Total Hip Arthroplasty

    PubMed Central

    Levine, Brett R.; Hsu, Andrew R.; Skipor, Anastasia K.; Hallab, Nadim J.; Paprosky, Wayne G.; Galante, Jorge O.; Jacobs, Joshua J.

    2013-01-01

    Abstract: We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times higher at 120 months than they were at baseline, and the CoCr total hip arthroplasty group had chromium levels that were 3.6 times higher at 120 months than they were at baseline. The serum titanium levels were higher in the titanium group at all follow-up time intervals as compared with the levels in all other groups, and the level in the titanium group at 120 months was eighteen times higher than it was at baseline (p < 0.01). Patients with well-functioning primary metal-on-polyethylene total hip replacements had elevated serum metal levels for as many as ten years postoperatively. Furthermore, metal release at the modular femoral head-neck junctions, rather than passive dissolution from porous ingrowth surfaces, was likely the dominant source of serum cobalt and chromium. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:23515985

  16. Online follow-up after total hip replacement: a first case

    PubMed Central

    Dexter, Caroline; Bradley, Benjamin; Williams, Daniel H

    2013-01-01

    With the current challenging financial climate in the NHS there is an increasing drive to reduce the number of postoperative follow-up appointments. We report on a patient who has successfully used a new online platform, www.myclinicaloutcomes.co.uk, to record condition-specific and generic wellbeing scores following total hip replacement. This case highlights the potential for remote follow-up of routine postoperative patients. PMID:23396931

  17. Association of Body Weight and Body Mass Index with Bone Mineral Density in Women and Men from Kosovo

    PubMed Central

    Rexhepi, Sylejman; Bahtiri, Elton; Rexhepi, Mjellma; Sahatciu-Meka, Vjollca; Rexhepi, Blerta

    2015-01-01

    Background and objective: Body weight and body mass index (BMI) are considered potentially modifiable determinants of bone mass. Therefore, the aim of this study was to explore the association between body weight and body mass index (BMI) with total hip and lumbar spine bone mineral density (BMD). Methods: This cross-sectional study included a population of 100 women and 32 men from Kosovo into three BMI groups. All the study subjects underwent dual-energy X-ray absorptiometry (DXA) measurements. Results: Total hip BMD levels of obese menopausal and premenopausal women and men were significantly higher compared to overweight or normal weight subjects, while lumbar spine BMD levels of only menopausal women and men were higher among obese subjects. Age-adjusted linear regression analysis showed that BMI is a significant independent associate of lumbar spine and total hip BMD in menopausal women and men. Conclusion: Despite positive association between BMI and lumbar spine and total hip BMD in menopausal women, presence of more obese and osteoporotic subjects among menopausal women represent a population at risk for fractures because of poor balance and frequent falls; therefore, both obesity and osteoporosis prevention efforts should begin early on in life. PMID:26543419

  18. Efficacy of Multimodal Pain Control Protocol in the Setting of Total Hip Arthroplasty

    PubMed Central

    Lee, Kyung-Jae; Bae, Ki-Cheor; Cho, Chul-Hyun; Kwon, Doo-Hyun

    2009-01-01

    Background This study evaluated the benefits and safety of a multimodal pain control protocol, which included a periarticular injection of local anesthetics, in patients undergoing total hip arthroplasty. Methods Between March 2006 and March 2007, 60 patients undergoing unilateral total hip arthroplasty were randomized to undergo either a multimodal pain control protocol or a conventional pain control protocol. The following parameters were compared: the preoperative and postoperative visual analogue scales (VAS), hospital stay, operative time, postoperative rehabilitation, additional painkiller consumption, and complication rates. Results There was no difference between the groups in terms of diagnosis, age, gender, and BMI. Although both groups had similar VAS scores in the preoperative period and on the fifth postoperative day, there was a significant difference between the groups over the four-day period after surgery. There were no differences in the hospital stay, operative time, additional painkiller consumption, or complication rate between the groups. The average time for comfortable crutch ambulation was 2.8 days in the multimodal pain control protocol group and 5.3 days in the control group. Conclusions The multimodal pain control protocol can significantly reduce the level of postoperative pain and improve patients' satisfaction, with no apparent risks, after total hip arthroplasty. PMID:19885051

  19. Monitoring the quality of total hip replacement in a tertiary care department using a cumulative summation statistical method (CUSUM).

    PubMed

    Biau, D J; Meziane, M; Bhumbra, R S; Dumaine, V; Babinet, A; Anract, P

    2011-09-01

    The purpose of this study was to define immediate post-operative 'quality' in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.

  20. [A project to provide instruction in the nursing of elderly patients with total hip replacement (T.H.R.)].

    PubMed

    Ting, Chao-Fong; Chou, Hsiu-Ling; Chen, Ming-Mie

    2006-02-01

    This project was aimed at improving the nursing of patients who have undergone total hip replacements. Investigation showed the following problems with existing nursing instruction in this area: lack of standard instruction, outdated educational materials, a 33.75% rate of completion of instruction lack of familiarity with instruction materials, and an average satisfaction score of 2.56 among nurses who have undergone instruction; The reading for patient's satisfaction with the guidance of nurses was 2.04. After site investigation, status analysis and reference check, we proposed the following program. (1) Establish standards and monitor tools for instruction for nursing total hip replacement patients, including "Caring standard", "Guidance for nursing instruction", "Nursing instruction sheet", "Notes at nursing instruction", "Satisfaction scoring system for nursing instruction"; (2) Carry out a training course to enhance nursing staff's knowledge about caring for patients with total hip replacement. After program had been implemented, a completion rate of 88.56% was achieved, and the satisfaction scores among nursing staff and patients were 4.3 and 4.36 respectively. This result shows that when we undertake reform at various different levels--including systemic structure, processing and monitoring--this can radically improve the quality of nursing instruction.

Top