Collector design for measuring high intensity time variant sprinkler application rates
USDA-ARS?s Scientific Manuscript database
Peak water application rate in relation to soil water infiltration rate and soil surface storage capacity is important in the design of center pivot sprinkler irrigation systems for efficient irrigation and soil erosion control. Measurement of application rates of center pivot irrigation systems ha...
Performance evaluation of a center pivot variable rate irrigation system
USDA-ARS?s Scientific Manuscript database
Variable Rate Irrigation (VRI) for center pivots offers potential to match specific application rates to non-uniform soil conditions along the length of the lateral. The benefit of such systems is influenced by the areal extent of these variations and the smallest scale to which the irrigation syste...
Automating variable rate irrigation management prescriptions for center pivots from field data maps
USDA-ARS?s Scientific Manuscript database
Variable rate irrigation (VRI) enables center pivot systems to match irrigation application to non-uniform field needs. This technology has potential to improve application and water-use efficiency while reducing environmental impacts from excess runoff and poor water quality. Proper management of V...
USDA-ARS?s Scientific Manuscript database
Recent developments in wireless sensor technology and remote sensing algorithms, coupled with increased use of center pivot irrigation systems, have removed several long-standing barriers to adoption of remote sensing for real-time irrigation management. One remote sensing-based algorithm is a two s...
Integration of wireless sensor networks into automatic irrigation scheduling of a center pivot
USDA-ARS?s Scientific Manuscript database
A six-span center pivot system was used as a platform for testing two wireless sensor networks (WSN) of infrared thermometers. The cropped field was a semi-circle, divided into six pie shaped sections of which three were irrigated manually and three were irrigated automatically based on the time tem...
Center pivot mounted infrared sensors: Retrieval of ET and interface with satellite systems
USDA-ARS?s Scientific Manuscript database
Infrared sensors mounted aboard cener pivot irrigation systems can remotely sense the surface temperatures of the crops and soils, which provides important information on crop water status. This can be used for irrigation management and irrigation automation, which can increase crop water productivi...
System for automatically aligning a support roller system under a rotating body
Singletary, B. Huston
1983-01-01
Two support rings on a rotatable drum respectively engage conically tapered nd surfaces of support rollers mounted on pivot universally relative to its axis of rotation and translate therealong. Rotation of the drum on differential conical support roller diameters causes pivotal steering and axial translation of support roller until roller is centered on support rings.
System for automatically aligning a support roller system under a rotating body
Singletary, B.H.
1982-07-21
Two support rings on a rotatable drum respectively engage conically tapered end surfaces of support rollers mounted on pivot universally relative to its axis of rotation and translate therealong. Rotation of the drum on differential conical support roller diameters causes pivotal steering and axial translation of support roller until roller is centered on support rings.
27. VIEW NORTHWEST FROM DECKING ON SOUTHEAST CORNER OF PIVOT ...
27. VIEW NORTHWEST FROM DECKING ON SOUTHEAST CORNER OF PIVOT PIER, DRIVE SYSTEM FOR SWING-SPAN INCLUDES: (from left to right) WEDGE DRIVE GEAR BOX, SHAFTS TO WEDGE DRIVE DRIVE, WEDGE DRIVE CRANK SHAFTS, ELECTRIC MOTOR, INTERNATIONAL HARVESTER GASOLINE ENGINE, CONTROL RODS FOR STARTING AND CHOKING ENGINE, PIVOT (bottom center), AND TRACK ON CONCRETE PIER - Tipers Bridge, Spanning Great Wicomico River at State Route 200, Kilmarnock, Lancaster County, VA
Center Pivot Irrigated Agriculture, Libya
NASA Technical Reports Server (NTRS)
1981-01-01
A view of the Faregh Agricultural Station in the Great Calanscio Sand Sea, Libya (26.5N, 22.0E) about 300 miles southeast of Benghazi. A pattern of water wells have been drilled several miles apart to support a quarter mile center-pivot-swing-arm agricultural irrigation system. The crop grown is alfalfa which is eaten on location by flocks of sheep following the swing arm as it rotates. At maturity, the sheep are flown to market throughout Libya.
Closeup view under the track at the center/pivot pier showing ...
Close-up view under the track at the center/pivot pier showing the system of distributing girders which transfer all the load of the swing span, both dead, live load, wind, etc., onto the circular drum, thence to the rim bearing 40 20-inch diameter wheels. Note: The track timber ties supported on the bottom truss chord of the swing span truss. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
NASA Technical Reports Server (NTRS)
Wennersten, Miriam; Banes, Vince; Boegner, Greg; Clagnett, Charles; Dougherty, Lamar; Edwards, Bernard; Roman, Joe; Bauer, Frank H. (Technical Monitor)
2001-01-01
NASA Goddard Space Flight Center has built an open architecture, 24 channel spaceflight Global Positioning System (GPS) receiver. The compact PCI PiVoT GPS receiver card is based on the Mitel/GEC Plessey Builder 2 board. PiVoT uses two Plessey 2021 correlators to allow tracking of up to 24 separate GPS SV's on unique channels. Its four front ends can support four independent antennas, making it a useful card for hosting GPS attitude determination algorithms. It has been built using space quality, radiation tolerant parts. The PiVoT card works at a lower signal to noise ratio than the original Builder 2 board. It also hosts an improved clock oscillator. The PiVoT software is based on the original Piessey Builder 2 software ported to the Linux operating system. The software is posix compliant and can be easily converted to other posix operating systems. The software is open source to anyone with a licensing agreement with Plessey. Additional tasks can be added to the software to support GPS science experiments or attitude determination algorithms. The next generation PiVoT receiver will be a single radiation hardened compact PCI card containing the microprocessor and the GPS receiver optimized for use above the GPS constellation.
NASA Technical Reports Server (NTRS)
Wennersten, Miriam Dvorak; Banes, Anthony Vince; Boegner, Gregory J.; Dougherty, Lamar; Edwards, Bernard L.; Roman, Joseph; Bauer, Frank H. (Technical Monitor)
2001-01-01
NASA Goddard Space Flight Center has built an open architecture, 24 channel space flight GPS receiver. The CompactPCI PiVoT GPS receiver card is based on the Mitel/GEC Plessey Builder-2 board. PiVoT uses two Plessey 2021 correlators to allow tracking of up to 24 separate GPS SV's on unique channels. Its four front ends can support four independent antennas, making it a useful card for hosting GPS attitude determination algorithms. It has been built using space quality, radiation tolerant parts. The PiVoT card will track a weaker signal than the original Builder 2 board. It also hosts an improved clock oscillator. The PiVoT software is based on the original Plessey Builder 2 software ported to the Linux operating system. The software is POSIX complaint and can easily be converted to other POSIX operating systems. The software is open source to anyone with a licensing agreement with Plessey. Additional tasks can be added to the software to support GPS science experiments or attitude determination algorithms. The next generation PiVoT receiver will be a single radiation hardened CompactPCI card containing the microprocessor and the GPS receiver optimized for use above the GPS constellation. PiVoT was flown successfully on a balloon in July, 2001, for its first non-simulated flight.
Detail of plate and gears on center pivot. From civilian ...
Detail of plate and gears on center pivot. From civilian land. Looking north. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
Variable rate irrigation (VRI)
USDA-ARS?s Scientific Manuscript database
Variable rate irrigation (VRI) technology is now offered by all major manufacturers of moving irrigation systems, mostly on center pivot irrigation systems. Variable irrigation depths may be controlled by sector only, in which case only the speed of the irrigation lateral is regulated. Or, variable ...
Center pivot, showing substantial beams that support the trusses. Looking ...
Center pivot, showing substantial beams that support the trusses. Looking north from civilian land. - Naval Supply Annex Stockton, Daggett Road Bridge, Daggett Road traversing Burns Cut Off, Stockton, San Joaquin County, CA
Effect of irrigation and silicon fertilizer on total rice grain arsenic content and yield
USDA-ARS?s Scientific Manuscript database
Field tests were conducted for two years with rice grown with different irrigation systems and rates of calcium silicate fertilizer to determine the effects on brown rice arsenic (As) levels and rough rice yields. Irrigation systems were sprinkler irrigation using a center pivot system, intermitten...
Yield response to variable rate irrigation in corn
USDA-ARS?s Scientific Manuscript database
To investigate the impact of variable rate irrigation on corn yield, twenty plots of corn were laid out under a center pivot variable rate irrigation (VRI) system in an experimental field near Stoneville, MS. The VRI system is equipped with five VRI zone control units, a global positioning system (G...
Assessing application uniformity of a variable rate irrigation system in a windy location
USDA-ARS?s Scientific Manuscript database
Variable rate irrigation (VRI) systems are commercially available and can easily be retrofitted onto moving sprinkler systems. However, there are few reports on the application performance of such equipment. In this study, application uniformity of two center pivots equipped with a commercial VRI sy...
NASA Technical Reports Server (NTRS)
2002-01-01
Center pivot irrigation systems create red circles of healthy vegetation in this image of croplands near Garden City, Kansas. This image was acquired by Landsat 7's Enhanced Thematic Mapper plus (ETM+) sensor on September 25, 2000. This is a false-color composite image made using near infrared, red, and green wavelengths. The image has also been sharpened using the sensor's panchromatic band. Image provided by the USGS EROS Data Center Satellite Systems Branch
NASA Astrophysics Data System (ADS)
Rodrigues, Lineu; Marioti, Juliana; Steenhuis, Tammo; Wallender, Wesley
2010-05-01
Irrigated agriculture is the major consumer of surface water in Brazil using over 70% of the total supply. Due to the growing competition for water among different sectors of the economy, sustainable water use can only be achieved by decreasing the portion of water used by the irrigated agriculture. Thus, in order to maintain yield, farmers need to irrigate more efficiently. There is little known on irrigation efficiency in Brazil. Therefore a study was carried out in the Buriti Vermelho basin to assess the irrigation performance of existing system. The experimental basin has a drainage area of 940 hectares and is located in the eastern part of the Federal District, in the Brazilian savanna region. Agriculture is the main activity. There is a dominance of red latosols. Several types of land use and crop cover are encountered in the basin. Conflicts among farmers for water are increasing. As water, in quality and quantity, is crucial to maintain the livelihood of the population in the basin, concern about risk of water lack due to climatic and land use change is in place. Once irrigation is the main water user in the basin, to increase water availability and reduce conflicts a water resource management plan has to be established. For this purpose, irrigation system performance has to be understood. The objective of this work was to assess the performance and the management of irrigation (small and big) that has been carried out by farmers in the Buriti Vermelho experimental watershed. A survey undertaken in 2007 was used to identify the irrigation systems in the basin. It was verified that irrigation is practiced by both small (area up to 6 hectare) and big farmers. Small farmers usually crop limes and vegetables and use micro-irrigation, drip, sprinkler, guns or furrow to irrigate them. Big farmers plant annual crops and use center pivot as irrigation system. In this first assessment 13 irrigation systems were evaluated: five conventional sprinklers, four drip systems, one microirrigation system and three center pivots schemes. Field evaluations used the method advocated by Keller and Bliesner and conducted during farmer scheduled irrigation. Soil samples were taken before irrigations to investigate adequacy of water applied. Since the irrigation water management and the uniformity of water distribution are the two major factors used to define the quality of irrigation, the following criteria for uniformity was used: i) Localized irrigations (distribution uniformity - UD) - excellent (90% < UD), acceptable (70% < UD < 90%), not acceptable (UD < 70); ii) Center pivots and conventional sprinkler irrigations (Christiansen coefficient - UC) - excellent (85% < UC), acceptable (85% < UC < 75%), not acceptable (UC < 75%). The water stored in the root zone after an irrigation event was compared with the real necessity. The results showed that: i) Localized irrigations - Three systems had UD < 70% and all systems presented deficit or excess of irrigation; ii) Conventional sprinkler system - Three system had UD smaller than 75% and all systems applied less water than the minimum necessary to keep an amount of water in the soil that don't cause plant stress; iii) Center pivot - In two system were observed UC < 75%. In one of the center pivots the depth applied was about 42% higher than the required and in the other two it was 39% and 47% lower. The study demonstrated the importance of adopting irrigation management criteria, in agricultural basins, once irrigation water becomes limiting and reduces basin water productivity.
Spatial ET field mapping using sensors mounted on a center pivot
USDA-ARS?s Scientific Manuscript database
Site-specific irrigation management is becoming more important for improving crop water use efficiency and reducing water wastage, especially as competition for quality water resources increases. Continuous geo-referenced canopy temperature measurements using sensors mounted on a center pivot irriga...
Efficient irrigation management with conventional and VRI sprinkler systems
USDA-ARS?s Scientific Manuscript database
In Alabama, there is a ploitical push towards irrigated agriculture, as reduction in water resources for agriculture in the West becomes more limited. Some farmers have invested in center pivot systems but have little experience with irrigation scheduling methods. ARS scientists at Bushland have e...
Wireless sensor network effectively controls center pivot irrigation of sorghum
USDA-ARS?s Scientific Manuscript database
Robust automatic irrigation scheduling has been demonstrated using wired sensors and sensor network systems with subsurface drip and moving irrigation systems. However, there are limited studies that report on crop yield and water use efficiency resulting from the use of wireless networks to automat...
Developing a hybrid solar/wind powered irrigation system for crops in the Great Plains
USDA-ARS?s Scientific Manuscript database
Some small scale irrigation systems (< 2 ha) powered by wind or solar do not require subsidies, but this paper discusses ways to achieve an economical renewable energy powered center pivot irrigation system for crops in the Great Plains. By adding a solar-photovoltaic (PV) array together with a wind...
NASA Technical Reports Server (NTRS)
Drew, J. V. (Principal Investigator)
1973-01-01
The author has identified the following significant results. Color composites generated from bands 4, 5, and 7 of MSS image 1061-16552 show that Aquic Haplustolls and Typic Haplaquolls can be separated from other subgroups present on Sand Hills rangeland. Since Aquic Haplustolls are suitable for establishment of center pivot irrigation systems, this provides one means of locating and assessing sites for the establishment of center pivot irrigation for irrigated pasture or other irrigated crops. This separation also provides for a rapid assessment of subirrigated land, much of which is used for harvest of hay. Subsequent estimates of hay production can then be made as ground truth establishes actual production levels.
Anticipatory postural adjustments for altering direction during walking.
Xu, Dali; Carlton, Les G; Rosengren, Karl S
2004-09-01
The authors examined how individuals adapt their gait and regulate their body configuration before altering direction during walking. Eight young adults were asked to change direction during walking with different turning angles (0 degree, 45 degree, 90 degree), pivot foot (left, right), and walking speeds (normal and fast). The authors used video and force platform systems to determine participants' whole-body center of mass and the center of pressure during the step before they changed direction. The results showed that anticipatory postural adjustments occurred during the prior step and occurred earlier for the fast walking speed. Anticipatory postural adjustments were affected by all 3 variables (turn angle, pivot foot, and speed). Participants leaned backward and sideward on the prior step in anticipation of the turn. Those findings indicate that the motor system uses central control mechanisms to predict the required anticipatory adjustments and organizes the body configuration on the basis of the movement goal.
Droplet Kinetic Energy from Center-Pivot Sprinklers
USDA-ARS?s Scientific Manuscript database
The kinetic energy of discrete water drops impacting a bare soil surface is generally observed to lead to a drastic reduction in water infiltration rate due to soil surface seal formation. Under center-pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy developmen...
Moving spray-plate center-pivot sprinkler rating index for assessing runoff potential
USDA-ARS?s Scientific Manuscript database
Numerous moving spray-plate center-pivot sprinklers are commercially available providing a range of drop size distributions and wetted diameters. A means to quantitatively compare sprinkler choices in regards to maximizing infiltration and minimizing runoff is currently lacking. The objective of thi...
Droplet kinetic energy of moving spray-plate center-pivot irrigation sprinklers
USDA-ARS?s Scientific Manuscript database
The kinetic energy of discrete water drops impacting a bare soil surface generally leads to a drastic reduction in water infiltration rate due to formation of a seal on the soil surface. Under center-pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy development ...
Determination of kinetic energy applied by center pivot sprinklers
USDA-ARS?s Scientific Manuscript database
The kinetic energy of discrete drops impacting a bare soil surface is generally observed to lead to a drastic reduction in water infiltration rate due to soil surface seal formation. Under center pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy development can...
Tarr, Robert; Hsu, Dan; Kulcsar, Zsolt; Bonvin, Christophe; Rufenacht, Daniel; Alfke, Karsten; Stingele, Robert; Jansen, Olav; Frei, Donald; Bellon, Richard; Madison, Michael; Struffert, Tobias; Dorfler, Arnd; Grunwald, Iris Q; Reith, Wolfgang; Haass, Anton
2010-12-01
The purpose of this study was to assess the initial post-market experience of the device and how it is compared with the Penumbra Pivotal trial used to support the 510k application. A retrospective case review of 157 consecutive patients treated with the Penumbra system at seven international centers was performed. Primary endpoints were revascularization of the target vessel (TIMI score of 2 or 3), good functional outcome as defined by a modified Rankin scale (mRS) score of ≤2 and incidence of procedural serious adverse events. Results were compared with those of the Penumbra pivotal trial. A total of 157 vessels were treated. Mean baseline values at enrollment were: age 65 years, NIHSS score 16. After use of the Penumbra system, 87% of the treated vessels were revascularized to TIMI 2 (54%) or 3 (33%) as compared with 82% reported in the Pivotal trial. Nine procedural serious adverse events were reported in 157 patients (5.7%). All-cause mortality was 20% (32/157), and 41% had a mRS of ≤2 at 90-day follow-up as compared with only 25% in the Pivotal trial. Patients who were successfully revascularized by the Penumbra system had significantly better outcomes than those who were not. Initial post-market experience of the Penumbra system revealed that the revascularization rate and safety profile of the device are comparable to those reported in the Pivotal trial. However, the proportion of patients who had good functional outcome was higher than expected.
Developing wind and/or solar powered crop irrigation systems for the Great Plains
USDA-ARS?s Scientific Manuscript database
Some small scale, off-grid irrigation systems (less than 2.5 ha) that are powered by wind or solar energy are cost effective, but this paper discusses ways to achieve an economical renewable energy powered center pivot irrigation system for crops in the Great Plains. It was found that partitioning t...
Earth Observations taken by the Expedition 10 crew
2004-10-28
ISS010-E-05266 (28 October 2004) --- The Al Khufrah Oasis is featured in this image photographed by an Expedition 10 crewmember on the International Space Station (ISS). Green circles in the desert frequently indicate tracts of agriculture supported by center-pivot irrigation. The Al Khufrah Oasis in southeastern Libya (near the Egyptian border) is one of Libyas largest agricultural projects, and is an easy-to-recognize landmark for orbiting crewmembers aboard the Station. The center-pivot irrigation system pumps water under pressure into a gantry or tubular arm from a central source. Anchored by a central pivot, the gantry slowly rotates over the area to be irrigated, thereby producing the circular patterns. Although the field diameters vary, these fields are approximately 0.6 mile (1 kilometer) in diameter. Darker colors indicate fields where such crops as wheat and alfalfa are grown. Lighter colors can indicate a variety of agricultural processes: fields that have been harvested recently; fields that are lying fallow; fields that have just been planted; or fields that have been taken out of production.
Fertigation - Injecting soluble fertilizers into the irrigation system
Thomas D. Landis; Jeremy R. Pinto; Anthony S. Davis
2009-01-01
Fertigation (fertilization + irrigation) is the newest way for nursery managers to apply fertilizer, and has become a standard practice in container nurseries. Because of the inherent inefficient water distribution patterns in field irrigation systems, fertigation has not been widely used in bareroot nurseries. However, a bareroot nursery with a center-pivot irrigation...
USDA-ARS?s Scientific Manuscript database
The kinetic energy of discrete drops impacting a bare soil surface is generally observed to lead to a drastic reduction in water infiltration rate due to soil surface seal formation. Under center pivot sprinkler irrigation, kinetic energy transferred to the soil prior to crop canopy development can...
Automated support tool for variable rate irrigation prescriptions
USDA-ARS?s Scientific Manuscript database
Variable rate irrigation (VRI) enables center pivot management to better meet non-uniform water and fertility needs. This is accomplished through correctly matching system water application with spatial and temporal variability within the field. A computer program was modified to accommodate GIS dat...
Method of vibration isolating an aircraft engine
NASA Technical Reports Server (NTRS)
Bender, Stanley I. (Inventor); Butler, Lawrence (Inventor); Dawes, Peter W. (Inventor)
1991-01-01
A method for coupling an engine to a support frame for mounting to a fuselage of an aircraft using a three point vibration isolating mounting system in which the load reactive forces at each mounting point are statically and dynamically determined. A first vibration isolating mount pivotably couples a first end of an elongated support beam to a stator portion of an engine with the pivoting action of the vibration mount being oriented such that it is pivotable about a line parallel to a center line of the engine. An aft end of the supporting frame is coupled to the engine through an additional pair of vibration isolating mounts with the mounts being oriented such that they are pivotable about a circumference of the engine. The aft mounts are symmetrically spaced to each side of the supporting frame by 45 degrees. The relative orientation between the front mount and the pair of rear mounts is such that only the rear mounts provide load reactive forces parallel to the engine center line, in support of the engine to the aircraft against thrust forces. The forward mount is oriented so as to provide only radial forces to the engine and some lifting forces to maintain the engine in position adjacent a fuselage. Since each mount is connected to provide specific forces to support the engine, forces required of each mount are statically and dynamically determinable.
Economic feasibility of converting center pivot irrigation to subsurface drip irrigation
USDA-ARS?s Scientific Manuscript database
Advancements in irrigation technology have increased water use efficiency. However, producers can be reluctant to convert to a more efficient irrigation system when the initial investment costs are high. This study examines the economic feasibility of replacing low energy precision application (LEPA...
A review of mechanical move sprinkler irrigation control and automation technologies
USDA-ARS?s Scientific Manuscript database
Electronic sensors, equipment controls, and communication protocols have been developed to meet the growing interest in site-specific irrigation using center pivot and lateral move irrigation systems. Onboard and field-distributed sensors can collect data necessary for real-time irrigation manageme...
Shu, Deming; Kearney, Steven P.; Preissner, Curt A.
2015-02-17
A method and deformation compensated flexural pivots structured for precision linear nanopositioning stages are provided. A deformation-compensated flexural linear guiding mechanism includes a basic parallel mechanism including a U-shaped member and a pair of parallel bars linked to respective pairs of I-link bars and each of the I-bars coupled by a respective pair of flexural pivots. The basic parallel mechanism includes substantially evenly distributed flexural pivots minimizing center shift dynamic errors.
NASA Technical Reports Server (NTRS)
Ryan, Robert E.; Irons, James; Spruce, Joseph P.; Underwood, Lauren W.; Pagnutti, Mary
2006-01-01
This study explores the use of synthetic thermal center pivot irrigation scenes to estimate temperature retrieval accuracy for thermal remote sensed data, such as data acquired from current and proposed Landsat-like thermal systems. Center pivot irrigation is a common practice in the western United States and in other parts of the world where water resources are scarce. Wide-area ET (evapotranspiration) estimates and reliable water management decisions depend on accurate temperature information retrieval from remotely sensed data. Spatial resolution, sensor noise, and the temperature step between a field and its surrounding area impose limits on the ability to retrieve temperature information. Spatial resolution is an interrelationship between GSD (ground sample distance) and a measure of image sharpness, such as edge response or edge slope. Edge response and edge slope are intuitive, and direct measures of spatial resolution are easier to visualize and estimate than the more common Modulation Transfer Function or Point Spread Function. For these reasons, recent data specifications, such as those for the LDCM (Landsat Data Continuity Mission), have used GSD and edge response to specify spatial resolution. For this study, we have defined a 400-800 m diameter center pivot irrigation area with a large 25 K temperature step associated with a 300 K well-watered field surrounded by an infinite 325 K dry area. In this context, we defined the benchmark problem as an easily modeled, highly common stressing case. By parametrically varying GSD (30-240 m) and edge slope, we determined the number of pixels and field area fraction that meet a given temperature accuracy estimate for 400-m, 600-m, and 800-m diameter field sizes. Results of this project will help assess the utility of proposed specifications for the LDCM and other future thermal remote sensing missions and for water resource management.
De Rosario, Helios; Page, Alvaro; Mata, Vicente
2014-05-07
This paper proposes a variation of the instantaneous helical pivot technique for locating centers of rotation. The point of optimal kinematic error (POKE), which minimizes the velocity at the center of rotation, may be obtained by just adding a weighting factor equal to the square of angular velocity in Woltring׳s equation of the pivot of instantaneous helical axes (PIHA). Calculations are simplified with respect to the original method, since it is not necessary to make explicit calculations of the helical axis, and the effect of accidental errors is reduced. The improved performance of this method was validated by simulations based on a functional calibration task for the gleno-humeral joint center. Noisy data caused a systematic dislocation of the calculated center of rotation towards the center of the arm marker cluster. This error in PIHA could even exceed the effect of soft tissue artifacts associated to small and medium deformations, but it was successfully reduced by the POKE estimation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Sayed-Hossein Sadeghi; Troy R. Peters; Mohammad Z. Amini; Sparkle L. Malone; Hank W. Loescher
2015-01-01
The increased need for water and food security requires the development of new approaches to save water through irrigation management strategies, particularly for center pivot irrigation. To do so entails monitoring of the dynamic variation in wind drift and evaporation losses (WDELs) of irrigation systems under different weather conditions and for relatively long time...
Airborne pathogens from dairy manure aerial irrigation and the human health risk
USDA-ARS?s Scientific Manuscript database
Application of liquid dairy manure by traveling gun or center pivot irrigation systems is becoming more common in Wisconsin because it offers several potential benefits: reduced road impacts from hauling, optimal timing for crop nutrient uptake, and reduced risks of manure runoff and groundwater con...
Bending and Torsion Load Alleviator With Automatic Reset
NASA Technical Reports Server (NTRS)
delaFuente, Horacio M. (Inventor); Eubanks, Michael C. (Inventor); Dao, Anthony X. (Inventor)
1996-01-01
A force transmitting load alleviator apparatus and method are provided for rotatably and pivotally driving a member to be protected against overload torsional and bending (moment) forces. The load alleviator includes at least one bias spring to resiliently bias cam followers and cam surfaces together and to maintain them in locked engagement unless a predetermined load is exceeded whereupon a center housing is pivotal or rotational with respect to a crown assembly. This pivotal and rotational movement results in frictional dissipation of the overload force by an energy dissipator. The energy dissipator can be provided to dissipate substantially more energy from the overload force than from the bias force that automatically resets the center housing and crown assembly to the normally fixed centered alignment. The torsional and bending (moment) overload levels can designed independently of each other.
USDA-ARS?s Scientific Manuscript database
The objectives of this study were to characterize wireless sensor nodes that we developed in terms of power consumption and functionality, and compare the performance of mesh and non-mesh wireless sensor networks (WSNs) comprised mainly of infrared thermometer thermocouples located on a center pivot...
NASA Astrophysics Data System (ADS)
Toyoda, Masahiro; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi; Tsutsui, Tatsuo; Sankai, Yoshiyuki
A monopivot centrifugal blood pump, whose impeller is supported with a pivot bearing and a passive magnetic bearing, is under development for implantable artificial heart. The hemolysis level is less than that of commercial centrifugal pumps and the pump size is as small as 160 mL in volume. To solve a problem of thrombus caused by fluid dynamics, flow visualization experiments and animal experiments have been undertaken. For flow visualization a three-fold scale-up model, high-speed video system, and particle tracking velocimetry software were used. To verify non-thrombogenicity one-week animal experiments were conducted with sheep. The initially observed thrombus around the pivot was removed through unifying the separate washout holes to a small centered hole to induce high shear around the pivot. It was found that the thrombus contours corresponded to the shear rate of 300s-1 for red thrombus and 1300-1700s-1 for white thrombus, respectively. Thus flow visualization technique was found to be a useful tool to predict thrombus location.
Ruggles, C.A.
1957-08-27
A swinging arm gage designed to measure radial angles, tapering, sloping, or arcuate concave surfaces is described. The principle of the swinging arm gage is that in any spherical system, radii and radial lines established by them pass through the center of the sphere. Thus if an arm be made to pivot at the sphere center, the path of the swinging end can be guided by a can so set as to establish the proper center angle, and dial indicators on the arm can be zeroed on a master object, angular and dimensional manufacturing errors can be determined on a duplicate object. This device makes possible a considerable saving of time in measuring complex arcuate contours.
Self-Balancing, Optical-Center-Pivot, Fast-Steering Mirror
NASA Technical Reports Server (NTRS)
Moore, James D.; Carson, Johnathan W.
2011-01-01
A complete, self-contained fast-steering- mirror (FSM) mechanism is reported consisting of a housing, a mirror and mirror-mounting cell, three PZT (piezoelectric) actuators, and a counterbalance mass. Basically, it is a comparatively stiff, two-axis (tip-tilt), self-balanced FSM. The present invention requires only three (or three pairs for flight redundancy) actuators. If a PZT actuator degrades, the inherent balance remains, and compensation for degraded stroke is made by simply increasing the voltage to the PZT. Prior designs typically do not pivot at the mirror optical center, creating unacceptable beam shear.
Circular buffer strips in center pivot irrigation for multiple benefits in the Southern Great Plains
USDA-ARS?s Scientific Manuscript database
The Ogallala Aquifer has converted the Southern Great Plains from a dust bowl to a highly productive agricultural region in the US. However, over exploitation of the aquifer is threatening sustainability of irrigated agriculture in the region. Partial pivots, where high water using conventional crop...
Measurement of the inertial properties of the Helios F-1 spacecraft
NASA Technical Reports Server (NTRS)
Gayman, W. H.
1975-01-01
A gravity pendulum method of measuring lateral moments of inertia of large structures with an error of less than 1% is outlined. The method is based on the fact that in a physical pendulum with a knife-edge support the distance from the axis of rotation to the system center of gravity determines the minimal period of oscillation and is equal to the system centroidal radius of gyration. The method is applied to results of a test procedure in which the Helios F-1 spacecraft was placed in a roll fixture with crossed flexure pivots as elastic constraints and system oscillation measurements were made with each of a set of added moment-of-inertia increments. Equations of motion are derived with allowance for the effect of the finite pivot radius and an error analysis is carried out to find the criterion for maximum accuracy in determining the square of the centroidal radius of gyration. The test procedure allows all measurements to be made with the specimen in upright position.
Perry, Charles A.
2006-01-01
Data compiled for the High Plains region of Kansas that includes five Groundwater Management Districts (GMDs) were analyzed for trends in irrigation water use, acres irrigated, precipitation, irrigation system types, and irrigated crop types to determine the effects of irrigation practices on water use over time. For the study period 1991 through 2003, precipitation decreased significantly (with 95-percent confidence) in northwestern and west-central Kansas but not in the southwestern and south-central parts of the State. Irrigation water use had no statistically significant trend during this period. There was a good (R= -0.77) relation between average regional precipitation and total GMD irrigation water use. When irrigation water use was adjusted for this relation, there was a positive trend (90-percent confidence level) in the adjusted irrigation water use. Another adjustment to water use was made using the ratio of annual precipitation to 1991-2005 average precipitation, which resulted in a negative trend (95-percent confidence level) in irrigation water use. This demonstrated the contradictory nature of precipitation adjustments to water use, making their utility somewhat suspect. GMD 3 in southwestern Kansas used 63 percent of the total acre-feet of irrigation water within all the GMDs. When all GMDs are considered, the number of irrigated acres for flood and center pivot systems without drop nozzles decreased significantly during the study period. At the same time the number of drop nozzle irrigated acres increased significantly. The number of irrigated acres of water-intensive crops (corn, alfalfa, and soybeans) also increased significantly, whereas the number of less- or non-water-intensive crops (grain sorghum and wheat), and multiple crop type acres decreased. Drop nozzle irrigation systems used approximately 2 percent less water in a year-by-year comparison than center pivot systems and 8 to 11 percent less water than flood irrigation. The best estimator of irrigation water use incorporated total acres irrigated and annual average or March-October regional precipitation. A conclusion that can be drawn from the trend analyses described in this report is that, although irrigation water use for all GMDs showed no statistically significant trend, an apparent increased efficiency of center pivots irrigation systems with drop nozzles has allowed more water-intensive crops to be grown on more irrigated acres.
2017-12-08
Center pivot irrigation systems create red circles of healthy vegetation in this image of croplands near Garden City, Kansas. This image was acquired by Landsat 7’s Enhanced Thematic Mapper plus (ETM+) sensor on September 25, 2000. This is a false-color composite image made using near infrared, red, and green wavelengths. The image has also been sharpened using the sensor’s panchromatic band. Credit: NASA/GSFC/Landsat NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Join us on Facebook
Irrigation trends in Kansas, 1991-2011
Kenny, Joan F.; Juracek, Kyle E.
2013-01-01
This fact sheet examines trends in total reported irrigation water use and acres irrigated as well as irrigation water use by crop type and system type in Kansas for the years 1991 through 2011. During the 21-year period, total reported irrigation water diversions varied substantially from year to year as affected primarily by climatic fluctuations. Total reported acres irrigated remained comparatively constant during this time, although acreages of irrigated corn increased and center pivots with drop nozzles became the dominant system type used for irrigation.
ERIC Educational Resources Information Center
Smith, Garnett J.; McDougall, Dennis; Edelen-Smith, Patricia
2006-01-01
Cumulative-hierarchical learning (CHL) and behavior, a premise first introduced by Staats in 1975, describes how higher-level behavioral patterns and structures can emerge from interactions among a set of lower-level actions. Proponents of CHL emphasize the importance of pivotal response interventions, behavior repertoires, generative learning,…
Agricultural and Ranching area, Rio Sao Francisco, Brazil
NASA Technical Reports Server (NTRS)
1990-01-01
This agricultural and Ranching area, Rio Sao Francisco, Brazil (13.0S, 43.5W) has been under study for several years. See scene STS-31-92-045 for comparison. This area has many small single family subsistence farms, large square and rectangular commercial farms and pastures for livestock grazing. Over the several years of observation, the number and size of farms has increased and center-pivot, swing-arm irrigation systems have been installed.
Irmak, A.; Singh, Ramesh K.; Walter-Shea, Elizabeth; Verma, S.B.; Suyker, A.E.
2011-01-01
We evaluated the performance of four models for estimating soil heat flux density (G) in maize (Zea mays L.) and soybean (Glycine max L.) fields under different irrigation methods (center-pivot irrigated fields at Mead, Nebraska, and subsurface drip irrigated field at Clay Center, Nebraska) and rainfed conditions at Mead. The model estimates were compared against measurements made during growing seasons of 2003, 2004, and 2005 at Mead and during 2005, 2006, and 2007 at Clay Center. We observed a strong relationship between the G and net radiation (Rn) ratio (G/Rn) and the normalized difference vegetation index (NDVI). When a significant portion of the ground was bare soil, G/Rn ranged from 0.15 to 0.30 and decreased with increasing NDVI. In contrast to the NDVI progression, the G/Rn ratio decreased with crop growth and development. The G/Rn ratio for subsurface drip irrigated crops was smaller than for the center-pivot irrigated crops. The seasonal average G was 13.1%, 15.2%, 10.9%, and 12.8% of Rn for irrigated maize, rainfed maize, irrigated soybean, and rainfed soybean, respectively. Statistical analyses of the performance of the four models showed a wide range of variation in G estimation. The root mean square error (RMSE) of predictions ranged from 15 to 81.3 W m-2. Based on the wide range of RMSE, it is recommended that local calibration of the models should be carried out for remote estimation of soil heat flux.
Joint for deployable structures
NASA Technical Reports Server (NTRS)
Craighead, N. D., II; Preliasco, R. J.; Hult, T. D. (Inventor)
1985-01-01
A joint is described for connecting a pair of beams to pivot them between positions in alignment or beside one another, which is of light weight and which operates in a controlled manner. The joint includes a pair of fittings and at least one center link having opposite ends pivotally connected to opposite fittings and having axes that pass through centerplates of the fittings. A control link having opposite ends pivotally connected to the different fittings controls their relative orientations, and a toggle assemly holds the fittings in the deployed configuration wherein they are aligned. The fittings have stops that lie on one side of the centerplane opposite the toggle assembly.
Variable Geometry Aircraft Wing Supported by Struts And/Or Trusses
NASA Technical Reports Server (NTRS)
Melton, John E. (Inventor); Dudley, Michael R. (Inventor)
2016-01-01
The present invention provides an aircraft having variable airframe geometry for accommodating efficient flight. The aircraft includes an elongated fuselage, an oblique wing pivotally connected with said fuselage, a wing pivoting mechanism connected with said oblique wing and said fuselage, and a brace operably connected between said oblique wing and said fuselage. The present invention also provides an aircraft having an elongated fuselage, an oblique wing pivotally connected with said fuselage, a wing pivoting mechanism connected with said oblique wing and said fuselage, a propulsion system pivotally connected with said oblique wing, and a brace operably connected between said propulsion system and said fuselage.
Constant lift rotor for a heavier than air craft
NASA Technical Reports Server (NTRS)
Stroub, R. H. (Inventor)
1979-01-01
A rotor blade extended radially from a hub, characterized by an elongated spar and a plurality of axially aligned shells pivotally mounted on the spar is presented. Each has an aerodynamic center located in trailing relation with the spar and supported thereby for simultaneous axial and angular displacement as centrifugal forces are applied, a pitch controller plus a plurality of pivotal pitch limiting arms transversely related to the spar. A push-pull link interconnecting the arms is used for imparting simultaneous pivotal motion, whereby the angular relationship of the arms to the spar is varied for varying the motion of the trucks along the arms for thus limiting the pitch of the segments about the spar.
Micro electro mechanical system optical switching
Thorson, Kevin J; Stevens, Rick C; Kryzak, Charles J; Leininger, Brian S; Kornrumpf, William P; Forman, Glenn A; Iannotti, Joseph A; Spahn, Olga B; Cowan, William D; Dagel, Daryl J
2013-12-17
The present disclosure includes apparatus, system, and method embodiments that provide micro electo mechanical system optical switching and methods of manufacturing switches. For example, one optical switch embodiment includes at least one micro electro mechanical system type pivot mirror structure disposed along a path of an optical signal, the structure having a mirror and an actuator, and the mirror having a pivot axis along a first edge and having a second edge rotatable with respect to the pivot axis, the mirror being capable of and arranged to be actuated to pivot betweeen a position parallel to a plane of an optical signal and a position substantially normal to the plane of the optical signal.
Pivot/Remote: a distributed database for remote data entry in multi-center clinical trials.
Higgins, S B; Jiang, K; Plummer, W D; Edens, T R; Stroud, M J; Swindell, B B; Wheeler, A P; Bernard, G R
1995-01-01
1. INTRODUCTION. Data collection is a critical component of multi-center clinical trials. Clinical trials conducted in intensive care units (ICU) are even more difficult because the acute nature of illnesses in ICU settings requires that masses of data be collected in a short time. More than a thousand data points are routinely collected for each study patient. The majority of clinical trials are still "paper-based," even if a remote data entry (RDE) system is utilized. The typical RDE system consists of a computer housed in the CC office and connected by modem to a centralized data coordinating center (DCC). Study data must first be recorded on a paper case report form (CRF), transcribed into the RDE system, and transmitted to the DCC. This approach requires additional monitoring since both the paper CRF and study database must be verified. The paper-based RDE system cannot take full advantage of automatic data checking routines. Much of the effort (and expense) of a clinical trial is ensuring that study data matches the original patient data. 2. METHODS. We have developed an RDE system, Pivot/Remote, that eliminates the need for paper-based CRFs. It creates an innovative, distributed database. The database resides partially at the study clinical centers (CC) and at the DCC. Pivot/Remote is descended from technology introduced with Pivot [1]. Study data is collected at the bedside with laptop computers. A graphical user interface (GUI) allows the display of electronic CRFs that closely mimic the normal paper-based forms. Data entry time is the same as for paper CRFs. Pull-down menus, displaying the possible responses, simplify the process of entering data. Edit checks are performed on most data items. For example, entered dates must conform to some temporal logic imposed by the study. Data must conform to some acceptable range of values. Calculations, such as computing the subject's age or the APACHE II score, are automatically made as the data is entered. Data that is collected serially (BP, HR, etc.) can be displayed graphically in a trend form along with other related variables. An audit trail is created that automatically tracks all changes to the original data, making it possible to reconstruct the CRF to any point in time. On-line help provides information on the study protocol as well as assistance with the use of the system. Electronic security makes it possible to lock certain parts of the CRF once it has been monitored. Completed CRFs are transmitted to the DCC via electronic mail where it is reviewed and merged into the study database. Questions about subject data are transmitted back to the CC via electronic mail. This approach to maintaining the study database is unique in that the study data files are distributed among the CC and DCC. Until a subject's CRF is monitored (verified against the original patient data residing in the hospital record), it logically resides at the CC where it was collected. Copies are transmitted to the DCC and are only read there. Any pre-monitoring changes must be made to the data at the CC. Once the subject's CRF is monitored, it logically moves to the DCC, and any subsequent changes are made at the DCC with copies of the CRF flowing back to the CC. 3. DISCUSSION. Pivot/Remote eliminates the need for paper forms by utilizing portable computers that can be used at the patient bedside. A GUI makes it possible to quickly enter data. Because the user gets instant feedback on possible error conditions, time is saved because the original data is close at hand. The ability to display trended data or variables in the context of other data allows detection of erroneous conditions beyond simple range checks. The logical construction of the database minimizes the problem of managing dual databases (at the CC and DCC) and keeps CC personnel in the loop until all changes are made.
Agricultural and Ranching area, Rio Sao Francisco, Brazil
1990-12-10
STS035-73-082 (2-10 Dec 1990) --- This agricultural and ranching area, Rio Sao Francisco, Brazil (13.0S, 43.5W) has been under study for several years. See scene STS-31-92-045 for comparison. This area has many small single family subsistence farms, large square and rectangular commercial farms and pastures for livestock grazing. Over the several years of observation, the number and size of farms has increased and center-pivot, swing-arm irrigation systems have been installed.
McKeown, Mark H.; Beason, Steven C.
1991-01-01
The radial arm strike rail assembly is a system for measurement of bearings, directions, and stereophotography for geologic mapping, particularly where magnetic compasses are not appropriate. The radial arm, pivoting around a shaft axis, provides a reference direction determination for geologic mapping and bearing or direction determination. The centerable and levelable pedestal provide a base for the radial arm strike rail and the telescoping camera pedestal. The telescoping feature of the radial arm strike rail allows positioning the end of the rail for strike direction or bearing measurement with a goniometer.
Steering system for a train of rail-less vehicles
Voight, Edward T.
1983-01-01
A steering system for use with a multiple vehicle train permits tracking without rails of one vehicle after another. This system is particularly useful for moving conveyor systems into and out of curved paths of room and pillar underground mine installations. The steering system features an elongated steering bar pivotally connected to each of adjacent vehicles at end portions of the bar permitting angular orientation of each vehicle in respect to the steering bar and other vehicles. Each end portion of the steering bar is linked to the near pair of vehicle wheels through wheel yoke pivot arms about king pin type pivots. Movement of the steering bar about its pivotal connection provides proportional turning of the wheels to effect steering and tracking of one vehicle following another in both forward and reverse directions.
Effects of Management Practices on Meloidogyne incognita and Snap Bean Yield.
Smittle, D A; Johnson, A W
1982-01-01
Phenamiphos applied at 6.7 kg ai/ha through a solid set or a center pivot irrigation system with 28 mm of water effectively controlled root-knot nematodes, Meloidogyne incognita, and resulted in greater snap bean growth and yields irrespective of growing season, tillage method, or cover crop system. The percentage yield increases attributed to this method of M. incognita control over nontreated controls were 45% in the spring crop, and 90% and 409% in the fall crops following winter rye and fallow, respectively. Root galling was not affected by tillage systems or cover crop, but disk tillage resulted in over 50% reduction in bean yield compared with yields from the subsoil-bed tillage system.
Method and system for dual resolution translation stage
Halpin, John Michael
2014-04-22
A dual resolution translation stage includes a stage assembly operable to receive an optical element and a low resolution adjustment device mechanically coupled to the stage assembly. The dual resolution stage also includes an adjustable pivot block mechanically coupled to the stage assembly. The adjustable pivot block includes a pivot shaft. The dual resolution stage further includes a lever arm mechanically coupled to the adjustable pivot block. The lever arm is operable to pivot about the pivot shaft. The dual resolution stage additionally includes a high resolution adjustment device mechanically coupled to the lever arm and the stage assembly.
Detail of middle panel at pivot pier and above the ...
Detail of middle panel at pivot pier and above the two (2) center supports. The middle panel chords (not shown) were made strong enough to provide for the full bending moment with the span open and arms swinging. The middle posts support the operator's house. When closed, the bridge acts as two (2) separate simple spans, except a small amount of negative bending is accommodated due to a continuous condition. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Perceived displacement explains wolfpack effect
Šimkovic, Matúš; Träuble, Birgit
2014-01-01
We investigate the influence of perceived displacement of moving agent-like stimuli on the performance in dynamic interactive tasks. In order to reliably measure perceived displacement we utilize multiple tasks with different task demands. The perceived center of an agent's body is displaced in the direction in which the agent is facing and this perceived displacement is larger than the theoretical position of the center of mass would predict. Furthermore, the displacement in the explicit judgment is dissociated from the displacement obtained by the implicit measures. By manipulating the location of the pivot point, we show that it is not necessary to postulate orientation as an additional cue utilized by perception, as has been suggested by earlier studies. These studies showed that the agent's orientation influences the detection of chasing motion and the detection-related performance in interactive tasks. This influence has been labeled wolfpack effect. In one of the demonstrations of the wolfpack effect participants control a green circle on a display with a computer mouse. It has been shown that participants avoid display areas with agents pointing toward the green circle. Participants do so in favor of areas where the agents point in the direction perpendicular to the circle. We show that this avoidance behavior arises because the agent's pivot point selected by the earlier studies is different from where people locate the center of agent's body. As a consequence, the nominal rotation confounds rotation and translation. We show that the avoidance behavior disappears once the pivot point is set to the center of agent's body. PMID:25566114
Drinking-Straw Microbalance and Seesaw: Stability and Instability
ERIC Educational Resources Information Center
Chapman, Peter; Glasser, Leslie
2015-01-01
The mechanics of a beam balance are little appreciated and seldom understood. We here consider the conditions that result in a stable balance, with center of gravity below the fulcrum (pivot point), while an unstable balance results when the center of gravity is above the fulcrum. The highly sensitive drinking-straw microbalance, which uses a…
Scott, Jill R.; Tremblay, Paul L.
2008-08-19
A laser device includes a virtual source configured to aim laser energy that originates from a true source. The virtual source has a vertical rotational axis during vertical motion of the virtual source and the vertical axis passes through an exit point from which the laser energy emanates independent of virtual source position. The emanating laser energy is collinear with an orientation line. The laser device includes a virtual source manipulation mechanism that positions the virtual source. The manipulation mechanism has a center of lateral pivot approximately coincident with a lateral index and a center of vertical pivot approximately coincident with a vertical index. The vertical index and lateral index intersect at an index origin. The virtual source and manipulation mechanism auto align the orientation line through the index origin during virtual source motion.
NASA Astrophysics Data System (ADS)
Li, Qingyun; Karnowski, Karol; Villiger, Martin; Sampson, David D.
2017-04-01
A fibre-based full-range polarisation-sensitive optical coherence tomography system is developed to enable complete capture of the structural and birefringence properties of the anterior segment of the human eye in a single acquisition. The system uses a wavelength swept source centered at 1.3 μm, passively depth-encoded, orthogonal polarisation states in the illumination path and polarisation-diversity detection. Off-pivot galvanometer scanning is used to extend the imaging range and compensate for sensitivity drop-off. A Mueller matrix-based method is used to analyse data. We demonstrate the performance of the system and discuss issues relating to its optimisation.
Earth observations taken from the shuttle Challenger during STS-41C
2009-06-25
41C-31-1002 (6-13 April 1984) --- Though previous photographs of this area have been taken prior to 41-C, that mission?s photography represents the best ever of ground water irrigation in Near East deserts. The system here is located in northeast Saudi Arabia, in the vicinity of Al Hufuf. Designed for use in the American west, the center pivot irrigation method pumps water from the ground and broadcasts it in a half-mile diameter circle from a mobile sprinkler system. This frame was one of the visuals used by the 41-C astronauts at their post-flight press conference.
First NAC Image Obtained in Mercury Orbit
2017-12-08
NASA image acquired: March 29, 2011 This is the first image of Mercury taken from orbit with MESSENGER’s Narrow Angle Camera (NAC). MESSENGER’s camera system, the Mercury Dual Imaging System (MDIS), has two cameras: the Narrow Angle Camera and the Wide Angle Camera (WAC). Comparison of this image with MESSENGER’s first WAC image of the same region shows the substantial difference between the fields of view of the two cameras. At 1.5°, the field of view of the NAC is seven times smaller than the 10.5° field of view of the WAC. This image was taken using MDIS’s pivot. MDIS is mounted on a pivoting platform and is the only instrument in MESSENGER’s payload capable of movement independent of the spacecraft. The other instruments are fixed in place, and most point down the spacecraft’s boresight at all times, relying solely on the guidance and control system for pointing. The 90° range of motion of the pivot gives MDIS a much-needed extra degree of freedom, allowing MDIS to image the planet’s surface at times when spacecraft geometry would normally prevent it from doing so. The pivot also gives MDIS additional imaging opportunities by allowing it to view more of the surface than that at which the boresight-aligned instruments are pointed at any given time. On March 17, 2011 (March 18, 2011, UTC), MESSENGER became the first spacecraft ever to orbit the planet Mercury. The mission is currently in the commissioning phase, during which spacecraft and instrument performance are verified through a series of specially designed checkout activities. In the course of the one-year primary mission, the spacecraft's seven scientific instruments and radio science investigation will unravel the history and evolution of the Solar System's innermost planet. Visit the Why Mercury? section of this website to learn more about the science questions that the MESSENGER mission has set out to answer. Credit: NASA/Johns Hopkins University Applied Physics Laboratory/Carnegie Institution of Washington NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Join us on Facebook
Estimation of optimal pivot point for remote center of motion alignment in surgery.
Rosa, Benoît; Gruijthuijsen, Caspar; Van Cleynenbreugel, Ben; Sloten, Jos Vander; Reynaerts, Dominiek; Poorten, Emmanuel Vander
2015-02-01
The determination of an optimal pivot point ([Formula: see text]) is important for instrument manipulation in minimally invasive surgery. Such knowledge is of particular importance for robotic-assisted surgery where robots need to rotate precisely around a specific point in space in order to minimize trauma to the body wall while maintaining position control. Remote center of motion (RCM) mechanisms are commonly used, where the RCM point is manually and visually aligned. If not positioned appropriately, this misalignment might lead to intolerably high forces on the body wall with increased risk of postoperative complications or instrument damage. An automated method to align the RCM with the [Formula: see text] was developed and tested. Computer vision and a lightweight calibration procedure are used to estimate the optimal pivot point. One or two pre-calibrated cameras viewing the surgical scene are employed. The surgeon is asked to make short pivoting movements, applying as little torque as possible, with an instrument of choice passing through the insertion point while camera images are being recorded. The physical properties of an instrument rotating around a pivot point are exploited in a random sample consensus scheme to robustly estimate the ideal position of the RCM in the image planes. Triangulation is used to estimate the RCM position in 3D. Experiments were performed on a specially designed mockup to test the method. The position of the pivot point is estimated with an average error less than 1.85 mm using two webcams placed from approximately 30 cm to 1 m away from the scene. The entire procedure was completed in a few seconds. In automated method to estimate the ideal position of the RCM was shown to be reliable. The method can be implemented within a visual servoing approach to automatically place the RCM point, or the results can be displayed on a screen to provide guidance to the surgeon. Further work includes the development of an image-guided alignment method and validation with in vivo experiments.
Design and Fabrication of the NASA Decoupler Pylon for the F-16 Aircraft
NASA Technical Reports Server (NTRS)
Clayton, J. D.; Haller, R. L.; Hassler, J. M., Jr.
1985-01-01
The NASA Decoupler Pylon is a passive means of suppressing wing-store flutter. The feasibility of demonstrating this concept on the F-16 aircraft was established through model wind tunnel tests and analyses. As a result of these tests and studies a ship set of Decoupler Pylons was designed and fabricated for a flight test demonstration on the F-16 aircraft. Basic design criteria were developed during the analysis study pertaining to pylon pitch stiffness, alignment system requirements, and damping requirements. A design was developed which utilized an electrical motor for the pylon alignment system. The design uses a four pin, two link pivot design which results in a remote pivot located at the center of gravity of the store when the store is in the aligned position. The pitch spring was fabricated from a tapered constant stress cantilevered beam. The pylon has the same external lines as the existing production pylon and is designed to use a MAU-12 ejection rack which is the same as the one used with the production pylon. The detailed design and fabrication was supported with a complete ground test of the pylon prior to shipment to NASA.
CALUTRON ASSEMBLING AND DISASSEMBLING APPARATUS
Andrews, R.E.
1959-01-27
The construction of a calutron tank is described, whcre the face plate of the tank carrying the ion separating mechanism may be inserted or withdrawn with a minimum of difficulty, even though the plate has considerable mass and the center of gravity of the plate assembly lies within the tank. In general, the plate is pivoted at its lower end by a specially designed hinge, whereby the weight of ths plate rests on the hinge when the plato is inserted in the tank opening. A pistoncylinder arrangement is mounted on the tank and attached at the top of the plate to produce sufficient force to pivot the plate out to a point where it withdraws by its own weight and to retard the natural tendency of the plate to close with heavy impact due to the unbalanced center of gravity of the plate assembly.
Mars Science Laboratory Rover Mobility Bushing Development
NASA Technical Reports Server (NTRS)
Riggs, Benjamin
2008-01-01
NASA s Mars Science Laboratory (MSL) Project will send a six-wheeled rover to Mars in 2009. The rover will carry a scientific payload designed to search for organic molecules on the Martian surface during its primary mission. This paper describes the development and testing of a bonded film lubricated bushing system to be used in the mobility system of the rover. The MSL Rover Mobility System contains several pivots that are tightly constrained with respect to mass and volume. These pivots are also exposed to relatively low temperatures (-135 C) during operation. The combination of these constraints led the mobility team to consider the use of solid film lubricated metallic bushings and dry running polymeric bushings in several flight pivot applications. A test program was developed to mitigate the risk associated with using these materials in critical pivots on the MSL vehicle. The program was designed to characterize bushing friction and wear performance over the expected operational temperature range (-135 C to +70 C). Seven different bushing material / lubricant combinations were evaluated to aid in the selection of the final flight pivot bushing material / lubricant combination.
Tsai, Liang-Ching; Lee, Song Joo; Yang, Aaron J.; Ren, Yupeng; Press, Joel M.; Zhang, Li-Qun
2014-01-01
Objective To examine whether an off-axis elliptical training program reduces pain and improves knee function in individuals with patellofemoral pain (PFP). Design Controlled laboratory study, pre-test-post-test. Setting University rehabilitation center. Participants Twelve adult subjects with PFP. Interventions Subjects with PFP completed an exercise program consisting of 18 sessions of lower extremity off-axis training using a custom-made elliptical trainer that allows frontal-plane sliding and transverse-plane pivoting of the footplates. Main Outcome Measures Changes in knee pain and function post-training and 6 weeks following training were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and International Knee Documentation Committee (IKDC) scores. Lower extremity off-axis control was assessed by pivoting and sliding instability, calculated as the root mean square (RMS) of the footplate pivoting angle and sliding distance during elliptical exercise. Subjects’ single-leg hop distance and proprioception in detecting lower extremity pivoting motion were also evaluated. Results Subjects reported significantly greater KOOS and IKDC scores (increased by 12–18 points) and hop distance (increased by 0.2 m) following training. A significant decrease in the pivoting and sliding RMS was also observed following training. Additionally, subjects with PFP demonstrated improved pivoting proprioception when tested under a minimum-weight-bearing position. Conclusions An off-axis elliptical training program was effective in enhancing lower extremity neuromuscular control on the frontal and transverse planes, reducing pain and improving knee function in persons with PFP. PMID:25591131
2012-07-09
Acquired by NASA Terra spacecraft on in 2011, this image shows the Wadi As-Sirhan Basin in northwest Saudi Arabia, which has been steadily developing agricultural fields using center pivot irrigation by tapping into fossil ground water.
AmeriFlux US-Ne2 Mead - irrigated maize-soybean rotation site
Suyker, Andy [University of Nebraska - Lincoln
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-Ne2 Mead - irrigated maize-soybean rotation site. Site Description - The study site is one of three fields (all located within 1.6 km of each other) at the University of Nebraska Agricultural Research and Development Center near Mead, Nebraska. This site is irrigated with a center pivot system. Prior to the initiation of the study, the irrigated site had a 10-yr history of maize-soybean rotation under no-till. A tillage operation (disking) was done just prior to the 2001 planting to homogenize the top 0.1 m of soil, incorporate P and K fertilizers, as well as previously accumulated surface residues. Since this tillage operation, the site has been under no-till management.
Efficient Execution Methods of Pivoting for Bulk Extraction of Entity-Attribute-Value-Modeled Data
Luo, Gang; Frey, Lewis J.
2017-01-01
Entity-attribute-value (EAV) tables are widely used to store data in electronic medical records and clinical study data management systems. Before they can be used by various analytical (e.g., data mining and machine learning) programs, EAV-modeled data usually must be transformed into conventional relational table format through pivot operations. This time-consuming and resource-intensive process is often performed repeatedly on a regular basis, e.g., to provide a daily refresh of the content in a clinical data warehouse. Thus, it would be beneficial to make pivot operations as efficient as possible. In this paper, we present three techniques for improving the efficiency of pivot operations: 1) filtering out EAV tuples related to unneeded clinical parameters early on; 2) supporting pivoting across multiple EAV tables; and 3) conducting multi-query optimization. We demonstrate the effectiveness of our techniques through implementation. We show that our optimized execution method of pivoting using these techniques significantly outperforms the current basic execution method of pivoting. Our techniques can be used to build a data extraction tool to simplify the specification of and improve the efficiency of extracting data from the EAV tables in electronic medical records and clinical study data management systems. PMID:25608318
General closeup view of the swing span bridge in the ...
General close-up view of the swing span bridge in the close position, looking upriver. The pivot/center pier is positioned in the center of Tennessee River. Note: Each arm of the continuous swing span acts as simple spans. The total span over four (4) supports is partially continuous-- the middle panel at the center pier is continuous for bending moments, but discontinuous for shears. - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
Morant, Anne Vinther; Vestergaard, Henrik Tang
2018-07-01
A minimum of two positive, adequate, and well-controlled clinical trials has historically been the gold standard for providing substantial evidence to support regulatory approval of a new medicine. Nevertheless, the present analysis of European Marketing Authorizations granted between 2012 and 2016 showed that 45% of new active substances were approved based on a single pivotal clinical trial. For therapeutic areas such as oncology and cardiovascular diseases, approvals based on a single pivotal trial are the rule rather than the exception, whereas new medicines within the nervous system area were generally supported by two or more pivotal trials. While overall similar trends have been observed in the US, the recent US Food and Drug Administration approvals of nervous system medicines based on a single pivotal trial suggest that a case-by-case scientific evaluation of the totality of evidence is increasingly applied to facilitate faster access of new medicines to patients suffering from serious diseases. © 2017 American Society for Clinical Pharmacology and Therapeutics.
Detailed view of one (1) arm of the swing bridge ...
Detailed view of one (1) arm of the swing bridge cantilevering out from the center/pivot pier on which the entire span is balanced at its center when in the open position. Both arms of the span have equal length. Note that the members are pin-connected at their connections (joints). - Bridgeport Swing Span Bridge, Spanning Tennessee River, Bridgeport, Jackson County, AL
PROCESS DESIGN MANUAL FOR LAND TREATMENT OF MUNICIPAL WASTEWATER
The USEPA guidance on land treatment of municipal and industrial wastewater is updated for the first time since 1984. The significant new technilogical changes include phytoremediation, vadose zone monitoring, new design approaches to surface irrigation, center pivot irrigation,...
Herbicide loading to shallow ground water beneath Nebraska's Management Systems Evaluation Area.
Spalding, Roy F; Watts, Darrell G; Snow, Daniel D; Cassada, David A; Exner, Mary E; Schepers, James S
2003-01-01
Better management practices can counter deterioration of ground water quality. From 1991 through 1996 the influence of improved irrigation practices on ground water pesticide contamination was assessed at the Nebraska Management Systems Evaluation Area. Three 13.4-ha corn (Zea mays L.) fields were studied: a conventional furrow-irrigated field, a surge-irrigated field and a center pivot-irrigated field, and a center pivot-irrigated alfalfa (Medicago sativa L.) field. The corn fields received one identical banded application of Bicep (atrazine [6-chloro-N-ethyl-N'-(1-methylethyl)-1,3,5-triazine-2,4,-diamine] + metolachlor [2-chloro-N-(2-ethyl-6-methylphenyl)-N-(2-methoxy-1-methylethyl) acetamidel) annually; the alfalfa field was untreated. Ground water samples were collected three times annually from 16 depths of 31 multilevel samplers. Six years of sample data indicated that a greater than 50% reduction in irrigation water on the corn management fields lowered average atrazine concentrations in the upper 1.5 m of the aquifer downgradient of the corn fields from approximately 5.5 to <0.5 microg L(-1). Increases in deethylatrazine (DEA; 2-chloro-4-amino-6-isopropylamino-s-triazine) to atrazine molar ratios indicated that reducing water applications enhanced microbial degradation of atrazine in soil zones. The occurrence of peak herbicide loading in ground water was unpredictable but usually was associated with heavy precipitation within days of herbicide application. Focused recharge of storm runoff that ponded in the surge-irrigated field drainage ditch, in the upgradient road ditch, and at the downgradient end of the conventionally irrigated field was a major mechanism for vertical transport. Sprinkler irrigation technology limited areas for focused recharge and promoted significantly more soil microbial degradation of atrazine than furrow irrigation techniques and, thereby, improved ground water quality.
Joint Center for Operational Analysis Journal. Volume 12, Issue 3, Winter 2010-2011
2011-01-01
building . One technique that worked well involved demonstra- tion projects such as green houses, center-pivot and drip irrigation, and grain silos...or other professional objectives such that failure is not really verifiable. A common example from foreign assistance project objectives is... professionals . Indeed, there is a long litany of far more egregious and damaging projects wholly planned and executed by development professionals
NASA Technical Reports Server (NTRS)
Chandler, Jesse M. (Inventor); Suciu, Gabriel L. (Inventor)
2018-01-01
An aircraft includes a propulsion supported within an aft portion of a fuselage A thrust reverser is mounted in the aft portion of the fuselage proximate the propulsion system for directing thrust in a direction to slow the aircraft. The thrust reverser includes an upper blocker door movable about a first pivot axis to a deployed position and a lower blocker door movable about a second pivot axis not parallel to the first pivot axis.
Potato Response to Tillage and Nitrogen Management
USDA-ARS?s Scientific Manuscript database
Potato responses to different rates of pre-plant and in-season N management are evaluated under reduced and conventional tillage under center pivot irrigation. Tuber yield, tuber size distribution, and tuber specific gravity were largely similar across different tillage and N management practices. P...
Logic-centered architecture for ubiquitous health monitoring.
Lewandowski, Jacek; Arochena, Hisbel E; Naguib, Raouf N G; Chao, Kuo-Ming; Garcia-Perez, Alexeis
2014-09-01
One of the key points to maintain and boost research and development in the area of smart wearable systems (SWS) is the development of integrated architectures for intelligent services, as well as wearable systems and devices for health and wellness management. This paper presents such a generic architecture for multiparametric, intelligent and ubiquitous wireless sensing platforms. It is a transparent, smartphone-based sensing framework with customizable wireless interfaces and plug'n'play capability to easily interconnect third party sensor devices. It caters to wireless body, personal, and near-me area networks. A pivotal part of the platform is the integrated inference engine/runtime environment that allows the mobile device to serve as a user-adaptable personal health assistant. The novelty of this system lays in a rapid visual development and remote deployment model. The complementary visual Inference Engine Editor that comes with the package enables artificial intelligence specialists, alongside with medical experts, to build data processing models by assembling different components and instantly deploying them (remotely) on patient mobile devices. In this paper, the new logic-centered software architecture for ubiquitous health monitoring applications is described, followed by a discussion as to how it helps to shift focus from software and hardware development, to medical and health process-centered design of new SWS applications.
NASA Technical Reports Server (NTRS)
Allton, Charles S. (Inventor); Okane, James H. (Inventor)
1989-01-01
This invention relates to a hatch and more particularly to a hatch for a space vehicle where the hatch has a low volume sweep and can be easily manipulated from either side of the hatch. The hatch system includes an elliptical opening in a bulkhead and an elliptical hatch member. The hatch cover system includes an elliptical port opening in a housing and an elliptical cover member supported centrally by a rotational bearing for rotation about a rotational axis normal to the cover member and by pivot pins in a gimbal member for pivotal movement about axes perpendicular to the rotational axis. Arm members support the gimbal member pivotally by pivot members so that upon rotation and manipulation the cover member can be articulatedly moved from a closed position to the port opening to an out of the way position with a minimum of volume sweep by the cover member.
A quantitative microbial risk assessment for center pivot irrigation of dairy wastewaters
USDA-ARS?s Scientific Manuscript database
In the western United States where livestock wastewaters are commonly land applied, there are concerns over individuals being exposed to airborne pathogens. In response, a quantitative microbial risk assessment (QMRA) was performed to estimate infectious risks from inhaling pathogens aerosolized dur...
Antaki, Elizabeth M; Vellidis, George; Harris, Casey; Aminabadi, Peiman; Levy, Karen; Jay-Russell, Michele T
2016-10-01
Studies have shown that irrigation water can be a vector for pathogenic bacteria. Due to this, the Food Safety Modernization Act's (FSMA) produce safety rule requires that agricultural water directly applied to produce be safe and of adequate sanitary quality for use, which may pose a challenge for some farmers. The purpose of this research was to assess the presence and concentration of Salmonella and generic Escherichia coli in irrigation water from distribution systems in a mixed produce production region of southern Georgia. Water samples were collected during three growing seasons at three farms irrigating crops with surface water (Pond 1, Pond 2) or groundwater (Well) during 2012-2013. Salmonella and generic E. coli populations were monitored by culture and Most Probable Number (MPN). Confirmed isolates were characterized by pulsed-field gel electrophoresis and serotyping. In Pond 1, Salmonella was detected in 2/21 surface, 5/26 subsurface, 10/50 center pivot, and 0/16 solid set sprinkler head water samples. In Pond 2, Salmonella was detected in 2/18 surface, 1/18 subsurface, 6/36 drip line start, and 8/36 drip line end water samples. Twenty-six well pumps and 64 associated drip line water samples were negative. The overall mean Salmonella concentration for positive water samples was 0.03 MPN/100 mL (range <0.0011-1.8 MPN/100 mL). Nine Salmonella serovars comprising 22 pulsotypes were identified. Identical serovars and subtypes were found three times on the same day and location: Pond 1-Pivot-Cantaloupe (serovar Rubislaw), Pond 1-Pivot-Peanut (serovar Saintpaul), and Pond 2-Drip Line Start-Drip Line End-Yellow Squash (serovar III_16z10:e,n,x,z15). Generic E. coli was detected in water from both farm ponds and irrigation distribution systems, but the concentrations met FSMA microbial water quality criteria. The results from this study will allow producers in southern Georgia to better understand how potential pathogens move through irrigation distribution systems.
Field-scale modeling of center pivot irrigated cotton: Oullman clay loam series
USDA-ARS?s Scientific Manuscript database
Regulatory ground water pumping restrictions continue to be debated in the Southern Ogallala Aquifer region and will eventually result in allocation of irrigation resources becoming more important. Models that address the temporal and spatial variability of water, energy, and nutrient balances at fi...
Advances in sprinkler irrigation management
USDA-ARS?s Scientific Manuscript database
Sprinkler irrigation is being increasingly adopted in the US and worldwide because it offers increased crop water productivity over what is possible with gravity irrigation. Most sprinkler irrigation is by center pivot, which is presently used on about 50 and 80 percent of land irrigated in the US a...
Cairo, Egypt/Nile River viewed from STS-66 Atlantis
1994-11-14
This close-up view of the intensively cultivated Nile River flood plain near Cairo presents a sharp color contrast to the virtually non-vegetated, sandy desert, located to the west of the vegetated area. Some rectangular cultivated field patterns, as well as circular center pivot irrigation patterns, can be observed northwest of the Nile River flood plain. The world famous Giza Pyramids are located near the center of this photography (see highly reflective sand surfaces).
LU Factorization with Partial Pivoting for a Multi-CPU, Multi-GPU Shared Memory System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurzak, Jakub; Luszczek, Pitior; Faverge, Mathieu
2012-03-01
LU factorization with partial pivoting is a canonical numerical procedure and the main component of the High Performance LINPACK benchmark. This article presents an implementation of the algorithm for a hybrid, shared memory, system with standard CPU cores and GPU accelerators. Performance in excess of one TeraFLOPS is achieved using four AMD Magny Cours CPUs and four NVIDIA Fermi GPUs.
58. VIEW OF SOUTHWEST SIDE OF LAUNCHER FROM ABOVE. AFRAME ...
58. VIEW OF SOUTHWEST SIDE OF LAUNCHER FROM ABOVE. A-FRAME PIVOT POINT IN CENTER OF PHOTOGRAPH; NITROGEN CONTROL UNIT IN UPPER LEFT CORNER OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
ERIC Educational Resources Information Center
Silverman, Linda Kreger
2016-01-01
Annemarie Roeper and Leta Hollingworth are the ethical bedrock of the field of gifted education. Though they never met, their legacies are intertwined. They gave us a child-centered perspective, in which ethical development plays a pivotal role. This article traces the similarities of their philosophies, exploring the life experiences that may…
Ganesan, Anand N; Kuklik, Pawel; Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H; Roberts-Thomson, Kurt C; Sanders, Prashanthan
2014-01-01
Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour.
Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A
2011-01-01
This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.
NASA Technical Reports Server (NTRS)
Seevers, P. M.; Lewis, D. T.; Drew, J. V.
1974-01-01
Interpretations of imagery from the Earth Resources Technology Satellite (ERTS-1) indicate that soil associations and attendant range sites can be identified on the basis of vegetation and topography using multi-temporal imagery. Optical density measurements of imagery from the visible red band of the multispectral scanner (MSS band 5) obtained during the growing season were related to field measurements of vegetative biomass, a factor that closely parallels range condition class on specific range sites. ERTS-1 imagery also permitted inventory and assessment of center-pivot irrigation systems in the Sand Hills region in relation to soil and topographic conditions and energy requirements.
Kasner, William H.; Racki, Daniel J.; Swenson, Clark E.
1984-01-01
A plurality of pivotal reflectors direct a high-power laser beam onto a workpiece, and a rotatable reflector is movable to a position wherein it intercepts the beam and deflects a major portion thereof away from its normal path, the remainder of the beam passing to the pivotal reflectors through an aperture in the rotating reflector. A plurality of targets are movable to positions intercepting the path of light traveling to the pivotal reflectors, and a preliminary adjustment of the latter is made by use of a low-power laser beam reflected from the rotating reflector, after which the same targets are used to make a final adjustment of the pivotal reflectors with the portion of the high-power laser beam passed through the rotating reflector.
A thermosensory pathway that controls body temperature
Nakamura, Kazuhiro; Morrison, Shaun F.
2008-01-01
Defending body temperature against environmental thermal challenges is one of the most fundamental homeostatic functions governed by the nervous system. Here we show a novel somatosensory pathway, which essentially constitutes the afferent arm of the thermoregulatory reflex triggered by cutaneous sensation of environmental temperature changes. Using rat in vivo electrophysiological and anatomical approaches, we revealed that lateral parabrachial neurons play a pivotal role in this pathway by glutamatergically transmitting cutaneous thermosensory signals received from spinal somatosensory neurons directly to the thermoregulatory command center, preoptic area. This feedforward pathway mediates not only sympathetic and shivering thermogenic responses but also metabolic and cardiac responses to skin cooling challenges. Notably, this ‘thermoregulatory afferent’ pathway exists in parallel with the spinothalamocortical somatosensory pathway mediating temperature perception. These findings make an important contribution to our understanding of both the somatosensory system and thermal homeostasis—two mechanisms fundamental to the nervous system and to our survival. PMID:18084288
A thermosensory pathway that controls body temperature.
Nakamura, Kazuhiro; Morrison, Shaun F
2008-01-01
Defending body temperature against environmental thermal challenges is one of the most fundamental homeostatic functions that are governed by the nervous system. Here we describe a somatosensory pathway that essentially constitutes the afferent arm of the thermoregulatory reflex that is triggered by cutaneous sensation of environmental temperature changes. Using in vivo electrophysiological and anatomical approaches in the rat, we found that lateral parabrachial neurons are pivotal in this pathway by glutamatergically transmitting cutaneous thermosensory signals received from spinal somatosensory neurons directly to the thermoregulatory command center, the preoptic area. This feedforward pathway mediates not only sympathetic and shivering thermogenic responses but also metabolic and cardiac responses to skin cooling challenges. Notably, this 'thermoregulatory afferent' pathway exists in parallel with the spinothalamocortical somatosensory pathway that mediates temperature perception. These findings make an important contribution to our understanding of both the somatosensory system and thermal homeostasis -- two mechanisms that are fundamental to the nervous system and to our survival.
77 FR 25647 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-01
... inspections of the outer diameter chrome on the center axles of the MLG for cracks; and related investigative... MLG for cracks; and related investigative and corrective actions if necessary. The related... operators Lubrication of MLG pivot joints.. 4 work-hours x $85 $0 $340 per $54,400 per per hour = $340...
USDA-ARS?s Scientific Manuscript database
In the western United States where dairy wastewaters are commonly land applied, there are concerns over individuals being exposed to airborne pathogens. In response, a quantitative microbial risk assessment (QMRA) was performed to estimate infectious risks after inhalation exposure of pathogens aero...
49 CFR 572.195 - Thorax with arm.
Code of Federal Regulations, 2014 CFR
2014-10-01
... accelerometers as specified in 49 CFR 572.200(d), and deflection potentiometers for the thorax and shoulder as... paragraphs (b)(3) and (4) of this section, the top of the shoulder rib mount (drawing 180-3352) orientation... the seat back incline passing through the center of the shoulder yoke assembly arm rotation pivot...
49 CFR 572.195 - Thorax with arm.
Code of Federal Regulations, 2013 CFR
2013-10-01
... accelerometers as specified in 49 CFR 572.200(d), and deflection potentiometers for the thorax and shoulder as... paragraphs (b)(3) and (4) of this section, the top of the shoulder rib mount (drawing 180-3352) orientation... the seat back incline passing through the center of the shoulder yoke assembly arm rotation pivot...
49 CFR 572.195 - Thorax with arm.
Code of Federal Regulations, 2012 CFR
2012-10-01
... accelerometers as specified in 49 CFR 572.200(d), and deflection potentiometers for the thorax and shoulder as... paragraphs (b)(3) and (4) of this section, the top of the shoulder rib mount (drawing 180-3352) orientation... the seat back incline passing through the center of the shoulder yoke assembly arm rotation pivot...
49 CFR 572.195 - Thorax with arm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... accelerometers as specified in 49 CFR 572.200(d), and deflection potentiometers for the thorax and shoulder as... paragraphs (b)(3) and (4) of this section, the top of the shoulder rib mount (drawing 180-3352) orientation... the seat back incline passing through the center of the shoulder yoke assembly arm rotation pivot...
The Competency Pivot: Introducing a Revised Approach to the Business Communication Curriculum
ERIC Educational Resources Information Center
Lucas, Kristen; Rawlins, Jacob D.
2015-01-01
In this article, we outline a competency-based approach to teaching business communication. At the heart of this approach, classroom instruction, assignments, and evaluation center on a goals-oriented and receiver-centric understanding of communication in which students are taught strategies for meeting five core competencies of business…
The Pivotal Role of Teacher Motivation in Tanzanian Education
ERIC Educational Resources Information Center
Davidson, Euan
2007-01-01
In Tanzania, the integral role that teachers play in providing a quality education for students has been recognized consistently in government documents (e.g., Ministry of Education and Culture [MOEC] 1995; 2001). However, concerns about the quality of teachers and teaching in Tanzania persist) Massawe and Kipingu 2000; Kuleana Center for…
NASA Technical Reports Server (NTRS)
Wing, David J.; Leavitt, Laurence D.; Re, Richard J.
1993-01-01
An investigation was conducted at wind-off conditions in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance characteristics of a single expansion-ramp nozzle with thrust-vectoring capability to 105 degrees. Thrust vectoring was accomplished by the downward rotation of an upper flap with adaptive capability for internal contouring and a corresponding rotation of a center-pivoted lower flap. The static internal performance of configurations with pitch thrust-vector angles of 0 degrees, 60 degrees, and 105 degrees each with two throat areas, was investigated. The nozzle pressure ratio was varied from 1.5 to approximately 8.0 (5.0 for the maximum throat area configurations). Results of this study indicated that the nozzle configuration of the present investigation, when vectored, provided excellent flow-turning capability with relatively high levels of internal performance. In all cases, the thrust vector angle was a function of the nozzle pressure ratio. This result is expected because the flow is bounded by a single expansion surface on both vectored- and unvectored-nozzle geometries.
Treytl, William J.; Slemmons, Arthur J.; Andeen, Gerry B.
1979-01-01
A heliostat apparatus includes a frame which is rotatable about an axis which is parallel to the aperture plane of an elongate receiver. A plurality of flat flexible mirror elements are mounted to the frame between several parallel, uniformly spaced resilient beams which are pivotally connected at their ends to the frame. Channels are mounted to the sides of the beams for supporting the edges of the mirror elements. Each of the beams has a longitudinally varying configuration designed to bow into predetermined, generally circular curvatures of varying radii when the center of the beam is deflected relative to the pivotally connected ends of the beams. All of the parallel resilient beams are simultaneously deflected by a cam shaft assembly extending through openings in the centers of the beams, whereby the mirror elements together form an upwardly concave, cylindrical reflecting surface. The heliostat is rotated about its axis to track the apparent diurnal movement of the sun, while the reflecting surface is substantially simultaneously bowed into a cylindrical trough having a radius adapted to focus incident light at the plane of the receiver aperture.
Support and maneuvering apparatus for solar energy receivers
Murphy, L.M.
1988-07-28
A support and maneuvering apparatus is disclosed for a solar energy receiving device adapted for receiving and concentrating solar energy and having a central axis extending through the center thereof. The apparatus includes a frame for mounting the perimeter of said solar energy receiving device. A support member extends along the central axis of the receiving device and has a base end passing through the center of the receiving device and an outer distal end adapted for carrying a solar energy receiving and conversion mechanism. A variable tension mechanism interconnects the support member with the frame to provide stiffening for the support member and the frame and to assist in the alignment of the frame to optimize the optical efficiency of the solar energy receiving device. A rotatable base is provided, and connecting members extend from the base for pivotable attachment to the frame at spaced positions therealong. Finally, an elevation assembly is connected to the receiving device for selectively pivoting the receiving about an axis defined between the attachment positions of the connecting members on the frame. 4 figs.
Support and maneuvering apparatus for solar energy receivers
Murphy, Lawrence M.
1989-01-01
A support and maneuvering apparatus is disclosed for a solar energy receiving device adpated for receiving and concentrating solar energy and having a central axis extending through the center thereof. The apparatus includes a frame for mounting the perimeter of said solar energy receiving device. A support member extends along the central axis of the receiving device and has a base end passing through the center of the receiving device and an outer distal end adapted for carrying a solar energy receiving and conversion mechanism. A variable tension mechanism interconnects the support member with the frame to provide stiffening for the support member and the frame and to assist in the alignment of the frame to optimize the optical efficiency of the solar energy receiving device. A rotatable base is provided, and connecting members extend from the base for pivotable attachment to the frame at spaced positions therealong. Finally, an elevation assembly is connected to the receiving device for selectively pivoting the receiving device about an axis defined between the attachment positions of the connecting members on the frame.
Koontz, Alicia M.; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L.; Cooper, Rory A.
2017-01-01
This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 non-disabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers. We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies. PMID:22068376
Design and evaluation of a single-pivot supported centrifugal blood pump.
Yoshino, M; Uemura, M; Takahashi, K; Watanabe, N; Hoshi, H; Ohuchi, K; Nakamura, M; Fujita, H; Sakamoto, T; Takatani, S
2001-09-01
In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a single-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.
Gharaviri, Ali; Brooks, Anthony; Chapman, Darius; Lau, Dennis H.; Roberts-Thomson, Kurt C.; Sanders, Prashanthan
2014-01-01
Background Rotors are postulated to maintain cardiac fibrillation. Despite the importance of bipolar electrograms in clinical electrophysiology, few data exist on the properties of bipolar electrograms at rotor sites. The pivot of a spiral wave is characterized by relative uncertainty of wavefront propagation direction compared to the periphery. The bipolar electrograms used in electrophysiology recording encode information on both direction and timing of approaching wavefronts. Objective To test the hypothesis that bipolar electrograms from the pivot of rotors have higher Shannon entropy (ShEn) than electrograms recorded at the periphery due to the spatial dynamics of spiral waves. Methods and Results We studied spiral wave propagation in 2-dimensional sheets constructed using a simple cell automaton (FitzHugh-Nagumo), atrial (Courtemanche-Ramirez-Nattel) and ventricular (Luo-Rudy) myocyte cell models and in a geometric model spiral wave. In each system, bipolar electrogram recordings were simulated, and Shannon entropy maps constructed as a measure of electrogram information content. ShEn was consistently highest in the pivoting region associated with the phase singularity of the spiral wave. This property was consistently preserved across; (i) variation of model system (ii) alterations in bipolar electrode spacing, (iii) alternative bipolar electrode orientation (iv) bipolar electrogram filtering and (v) in the presence of rotor meander. Directional activation plots demonstrated that the origin of high ShEn at the pivot was the directional diversity of wavefront propagation observed in this location. Conclusions The pivot of the rotor is consistently associated with high Shannon entropy of bipolar electrograms despite differences in action potential model, bipolar electrode spacing, signal filtering and rotor meander. Maximum ShEn is co-located with the pivot for rotors observed in the bipolar electrogram recording mode, and may be an intrinsic property of spiral wave dynamic behaviour. PMID:25401331
USDA-ARS?s Scientific Manuscript database
Declining Ogallala Aquifer has threatened sustainability of highly productive irrigated agriculture in the region. The region, known for the dust bowl of thirties, is scared of its return. Lower well outputs and increasing pumping costs have compelled farmers to adapt alternative conservation strate...
ERIC Educational Resources Information Center
Lee, Stephen
2010-01-01
The purpose of this study was to evaluate the implementation of enrollment management at two public universities. The theoretical framework was conceptual and centered on the effectiveness of the implementation process as a pivotal factor in the development of a comprehensive enrollment management operation. This multi-site case study included 14…
Formative Research in Ubiquitous and Virtual Environments in Higher Education
ERIC Educational Resources Information Center
Velandia-Mesa, Cristian; Serrano-Pastor, Francisca-José; Martínez-Segura, María-José
2017-01-01
Academic training in research is fundamental in the quality of higher education and within this context, technological mediation becomes pivotal to reach student-centered learning objectives in any moment and at any time. The findings of a study, the purpose of which has been to evaluate the results of the formative research of two groups of…
49 CFR 572.76 - Limbs assembly and test procedure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... between 1g and 2g. (ii) Place the dummy legs in a plane parallel to the dummy's midsagittal plane with the knee pivot center line perpendicular to the dummy's midsagittal plane, and with the feet flat on the... parallel to the midsagittal plane at the specified velocity. (5) Guide the test probe during impact so that...
Description of a prototype emission-transmission computed tomography imaging system
NASA Technical Reports Server (NTRS)
Lang, T. F.; Hasegawa, B. H.; Liew, S. C.; Brown, J. K.; Blankespoor, S. C.; Reilly, S. M.; Gingold, E. L.; Cann, C. E.
1992-01-01
We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.
NASA Technical Reports Server (NTRS)
Weems, J.; Wyse, N.; Madura, J.; Secrist, M.; Pinder, C.
1991-01-01
Lightning plays a pivotal role in the operation decision process for space and ballistic launches at Cape Canaveral Air Force Station and Kennedy Space Center. Lightning forecasts are the responsibility of Detachment 11, 4th Weather Wing's Cape Canaveral Forecast Facility. These forecasts are important to daily ground processing as well as launch countdown decisions. The methodology and equipment used to forecast lightning are discussed. Impact on a recent mission is summarized.
Split-core heat-pipe reactors for out-of-pile thermionic power systems.
NASA Technical Reports Server (NTRS)
Niederauer, G.; Lantz, E.; Breitweiser, R.
1971-01-01
Description of the concept of splitting a heat-pipe reactor for out-of-core thermionics into two identical halves and using the resulting center gap for reactivity control. Short Li-W reactor heat pipes penetrate the axial reflectors and form a heat exchanger with long heat pipes which wind through the shield to the thermionic diodes. With one reactor half anchored to the shield, the other is attached to a long arm with a pivot behind the shield and swings through a small arc for reactivity control. A safety shim prevents large reactivity inputs, and a fueled control arm drive shaft acts as a power stabilizer. Reactors fueled with U-235C and with U-233C have been studied.-
NASA Technical Reports Server (NTRS)
Behar, Alberto E. (Inventor); Marzwell, Neville I. (Inventor); Wall, Jonathan N. (Inventor); Poole, Michael D. (Inventor)
2011-01-01
A robot and robot system that are capable of functioning in a zero-gravity environment are provided. The robot can include a body having a longitudinal axis and having a control unit and a power source. The robot can include a first leg pair including a first leg and a second leg. Each leg of the first leg pair can be pivotally attached to the body and constrained to pivot in a first leg pair plane that is substantially perpendicular to the longitudinal axis of the body.
Remote pivot decoupler pylon: Wing/store flutter suppressor
NASA Technical Reports Server (NTRS)
Hassler, J. M., Jr. (Inventor)
1986-01-01
A device for suspending a store from an aerodynamic support surface, such an an aircraft wing, and more specifically, for improving upon singlet pivot decoupler pylons by reducing both frequency of active store, alignment, and alignment system space and power requirements. Two links suspend a lower pylon/rack section and releasable attached store from an upper pylon section mounted under the wing. The links allow the lower pylon section to rotate in pitch about a remote pivot point. A leaf spring connected between the lower section and electrical alignment system servomechanism provides pitch alignment of the lower section/store combination. The servomechanism utilizes an electric servomotor to drive the gear train and reversibly move the leaf spring, thereby maintaining the pitch attitude of the store within acceptable limits. The damper strokes when the lower section rotates to damp large oscillations of store.
Engaging Employees in Well-Being: Moving From the Triple Aim to the Quadruple Aim.
Jacobs, Barbara; McGovern, Julie; Heinmiller, Jamie; Drenkard, Karen
Anne Arundel Medical Center has been on a 3-year journey to improve employee well-being with the assumption that employee well-being and employee engagement are interconnected. Improvements in employee well-being will result in increased employee engagement and will be a pivotal driver to assist the health system meet its goals. Historically, Anne Arundel Medical Center successfully differentiated itself in the market by being the region's high-quality, low-cost provider of health services delivered through intense collaboration with patients and families. The financial, quality, and patient satisfaction results are in the top percentiles nationwide. However, as the pace of change accelerates and the organization faces increased pressure to improve outcomes, keeping employees from becoming burned out and disengaged becomes an increasing concern. The WellBeing framework was developed on the basis of the work of Tom Rath and Jim Harter as the model to support Anne Arundel's WellBeing work. The efforts around well-being are comprehensive and impact all aspects of how work is conducted. Employee well-being has been elevated to an equal third prong along with providing high-quality low-cost care in a patient-centered environment. This focus on leading an employee WellBeing Program has resulted in improved engagement scores at Anne Arundel Medical Center.
Identification of Communication and Coordination Issues in the US Air Traffic Control System
NASA Technical Reports Server (NTRS)
Davison, Hayley J.; Hansman, R. John
2001-01-01
Today's air traffic control system is approaching the point of saturation, as evidenced by increasing delays across the National Airspace System (NAS). There exists an opportunity to enhance NAS efficiency and reduce delays by improving strategic communication throughout the ATC system. Although several measures have been taken to improve communication (e.g., Collaborative Decision Making tools), communication issues between ATC facilities remain. It is hypothesized that by identifying the key issues plaguing inter-facility strategic communication, steps can be taken to enhance these communications, and therefore ATC system efficiency. In this report, a series of site visits were performed at Boston and New York ATC facilities as well as at the Air Traffic Control System Command Center. The results from these site visits were used to determine the current communication and coordination structure of Traffic Management Coordinators, who hold a pivotal role in inter-facility communications. Several themes emerged from the study, including: ambiguity of organizational structure in the current ATC system, awkward coordination between ATC facilities, information flow issues, organizational culture issues, and negotiation behaviors used to cope with organizational culture issues.
Design for validation: An approach to systems validation
NASA Technical Reports Server (NTRS)
Carter, William C.; Dunham, Janet R.; Laprie, Jean-Claude; Williams, Thomas; Howden, William; Smith, Brian; Lewis, Carl M. (Editor)
1989-01-01
Every complex system built is validated in some manner. Computer validation begins with review of the system design. As systems became too complicated for one person to review, validation began to rely on the application of adhoc methods by many individuals. As the cost of the changes mounted and the expense of failure increased, more organized procedures became essential. Attempts at devising and carrying out those procedures showed that validation is indeed a difficult technical problem. The successful transformation of the validation process into a systematic series of formally sound, integrated steps is necessary if the liability inherent in the future digita-system-based avionic and space systems is to be minimized. A suggested framework and timetable for the transformtion are presented. Basic working definitions of two pivotal ideas (validation and system life-cyle) are provided and show how the two concepts interact. Many examples are given of past and present validation activities by NASA and others. A conceptual framework is presented for the validation process. Finally, important areas are listed for ongoing development of the validation process at NASA Langley Research Center.
An analysis of the Dahl friction model and its effect on a CMG gimbal rate controller
NASA Technical Reports Server (NTRS)
Nurre, G. S.
1974-01-01
The effects of friction, represented by the Dahl model, on a CMG rate control system was investigated by digital simulation. The conclusion from these simulation results is that gimbal pivot friction can be a significant effect on the gimbal rate control system. The magnitude of the problem this presents depends on the characteristics of the actual pivot. It would appear from this preliminary look that one solution is to insure that the control system natural frequency is higher by some prescribed amount than the natural frequency of the friction loop.
Central Facilities Area Sewage Lagoon Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giesbrecht, Alan
2015-03-01
The Central Facilities Area (CFA) located in Butte County, Idaho at Idaho National Laboratory (INL) has an existing wastewater system to collect and treat sanitary wastewater and non contact cooling water from the facility. The existing treatment facility consists of three cells: Cell 1 has a surface area of 1.7 acres, Cell 2 has a surface area of 10.3 acres, and Cell 3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5 acre land application site that utilizes a center pivot irrigation sprinkler system. The purpose ofmore » this current study is to update the analysis and conclusions of the December 2013 study. In this current study, the new seepage rate and influent flow rate data have been used to update the calculations, model, and analysis.« less
Service of Remembrance: a comprehensive cancer center's response to bereaved family members.
Knight, Louise; Cooper, Rhonda S; Hypki, Cinder
2012-01-01
Comprehensive cancer centers that offer an array of clinical trials and treatment options often experience significant patient mortality rates. Bereavement resources may not be routinely incorporated into the service delivery model in these specialty hospitals. In response, an interdisciplinary team at one cancer center proposed, planned, and implemented an annual Service of Remembrance. The incorporation of music, poetry, and visual arts was important in designing a program that would provide a meaningful, spiritual experience. A community artist who designed an interactive memorial art piece played a pivotal role. This article outlines the process of institutional culture change and describes future challenges in the implementation of this type of bereavement service.
USDA-ARS?s Scientific Manuscript database
Corn (Zea mays L.) for feed is an important crop in the Texas High Plains region. However, it requires more water than the other major crops grown in the area to maximize grain yields. Pumping water for agriculture from the declining Ogallala Aquifer is of concern and improving irrigation water use ...
ERIC Educational Resources Information Center
Gelso, Charles J.
This theoretical paper is based on the premise that nearly all people who enter therapy do so, to varying degrees, with the wish (conscious or unconscious demand) to have dependent longing and affectional needs gratified in the therapy itself. The conditions under, and the extent to which, the therapist provides direct gratification are crucial…
Autonomy or Oligarchy? The Changing Effects of University Endowments in Winner-Take-All Markets
ERIC Educational Resources Information Center
Meyer, Heinz-Dieter; Zhou, Kai
2017-01-01
This paper directs attention to important changes in the role and funding of elite private universities in the USA. At the center of these changes is the private endowment--an institution that has for much of its history been a pivotal element of innovation and autonomy, but which is recently tilting towards the production and reproduction of…
ERIC Educational Resources Information Center
Starks, Luciana Janee'
2010-01-01
Increasing the number of advanced degree recipients is more than an educational issue; it is also a key social issue. "A college-educated population results in pivotal benefits to society" (The National Center for Public Policy and Higher Education, 2004, p. 1). Although African Americans have made steady and notable progress in doctorate degree…
Salmon, Marla E; Maeda, Akiko
2016-01-01
In September of 2014, the Institute of Medicine (IOM) convened a global Rockefeller Bellagio Center workshop focusing on the largely overlooked area of investment in nursing and midwifery enterprise as a means for both empowering women and strengthening health systems and services. The report of this meeting, Empowering Women and Strengthening Health Systems and Services Through Investing in Nursing and Midwifery Enterprise: Lessons from Lower-Income Countries: Workshop Summary, was released in February, 2015. This report represents a pivotal point in a growing body of work begun in 2012, providing insights and perspectives of global experts that have resulted in subsequent global discussions and are paving the way for the future. This three-part article summarizes the initial exploration leading to the IOM workshop and report, followed by highlights and insights from the report and related meetings, and authors concluding discussion of implications for the future and next steps. Copyright © 2016 Elsevier Inc. All rights reserved.
Tracking system for solar collectors
Butler, Barry L.
1984-01-01
A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.
Tracking system for solar collectors
Butler, B.
1980-10-01
A tracking system is provided for pivotally mounted spaced-apart solar collectors. A pair of cables is connected to spaced-apart portions of each collector, and a driver displaces the cables, thereby causing the collectors to pivot about their mounting, so as to assume the desired orientation. The collectors may be of the cylindrical type as well as the flat-plate type. Rigid spar-like linkages may be substituted for the cables. Releasable attachments of the cables to the collectors is also described, as is a fine tuning mechanism for precisely aligning each individual collector.
2015-10-20
In the middle of the Arabian desert the city Green Oasis Wadi Al Dawasir is being developed as a new urban center for the Wadi Al Dawasir region of Saudi Arabia, as shown in this image from NASA Terra spacecraft. Huge solar fields supply the entire city and the surrounding region with energy. Hundreds of circular agricultural fields are fed by center pivot irrigation apparatus, drawing water from subterranean aquifers. The image was acquired March 30, 2013, covers an area of 30 x 45 km, and is located at 20.2 degrees north, 44.8 degrees east. http://photojournal.jpl.nasa.gov/catalog/PIA20077
Balloon-borne 3-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, G. G.
1986-01-01
The gimbal design was studied and revised to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball-bearings to replace the flex-pivot was defined and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared. Mirror development and the test program using mirror test blanks from Dornier were continued.
Balloon-borne three-meter telescope for far-infrared and submillimeter astronomy
NASA Technical Reports Server (NTRS)
Fazio, Giovanni G.
1986-01-01
The study and revision of the gimbal design of the Three-Meter Balloon Borne Telescope (TMBBT) is discussed. Efforts were made to eliminate the alignment and limited rotation problems inherent in the flex-pivot design. A new design using ball bearings to replace the flex-pivots was designed and its performance analyzed. An error analysis for the entire gondola pointing system was also prepared.
Tactical Firefighter Teams: Pivoting Toward the Fire Service’s Evolving Homeland Security Mission
2016-09-01
critical response command C-TECC Committee on Tactical Emergency Casualty Care EMS emergency medical services EMT emergency medical technician ESU...Interagency Tactical Response Model: Integrating Fire and EMS with Law Enforcement to Mitigate Mumbai-Style Terrorist Attacks (New York: FDNY Center...the assailants, several traditional fire and EMS activities must often occur simultaneously to successfully mitigate the threat. Although rare
Shoulder Injuries in US Astronauts Related to EVA Suit Design
NASA Technical Reports Server (NTRS)
Scheuring, R. A.; McCulloch, P.; Van Baalen, Mary; Minard, Charles; Watson, Richard; Blatt, T.
2011-01-01
Introduction: For every one hour spent performing extravehicular activity (EVA) in space, astronauts in the US space program spend approximately six to ten hours training in the EVA spacesuit at NASA-Johnson Space Center's Neutral Buoyancy Lab (NBL). In 1997, NASA introduced the planar hard upper torso (HUT) EVA spacesuit which subsequently replaced the existing pivoted HUT. An extra joint in the pivoted shoulder allows increased mobility but also increased complexity. Over the next decade a number of astronauts developed shoulder problems requiring surgical intervention, many of whom performed EVA training in the NBL. This study investigated whether changing HUT designs led to shoulder injuries requiring surgical repair. Methods: US astronaut EVA training data and spacesuit design employed were analyzed from the NBL data. Shoulder surgery data was acquired from the medical record database, and causal mechanisms were obtained from personal interviews Analysis of the individual HUT designs was performed as it related to normal shoulder biomechanics. Results: To date, 23 US astronauts have required 25 shoulder surgeries. Approximately 48% (11/23) directly attributed their injury to training in the planar HUT, whereas none attributed their injury to training in the pivoted HUT. The planar HUT design limits shoulder abduction to 90 degrees compared to approximately 120 degrees in the pivoted HUT. The planar HUT also forces the shoulder into a forward flexed position requiring active retraction and extension to increase abduction beyond 90 degrees. Discussion: Multiple factors are associated with mechanisms leading to shoulder injury requiring surgical repair. Limitations to normal shoulder mechanics, suit fit, donning/doffing, body position, pre-existing injury, tool weight and configuration, age, in-suit activity, and HUT design have all been identified as potential sources of injury. Conclusion: Crewmembers with pre-existing or current shoulder injuries or certain anthropometric body types should conduct NBL EVA training in the pivoted HUT.
Effects of pivoting neuromuscular training on pivoting control and proprioception.
Lee, Song Joo; Ren, Yupeng; Chang, Alison H; Geiger, François; Zhang, Li-Qun
2014-07-01
Pivoting neuromuscular control and proprioceptive acuity may play an important role in anterior cruciate ligament injuries. The goal of this study was to investigate whether pivoting off-axis intensity adjustable neuromuscular control training (POINT) could improve pivoting neuromuscular control, proprioceptive acuity, and functional performance. Among 41 subjects, 21 subjects participated in 18 sessions of POINT (three sessions per week for 6 wk), and 20 subjects served as controls who did their regular workout. Both groups received pre-, mid-, and postintervention evaluations. Propensity score analysis with multivariable regression adjustment was used to investigate the effect of training on pivoting neuromuscular control (pivoting instability, leg pivoting stiffness, maximum internal, and external pivoting angles), proprioceptive acuity, and functional performance in both groups. Compared with the control group, the training group significantly improved pivoting neuromuscular control as reduced pivoting instability, reduced maximum internal and external pivoting angles, increased leg pivoting stiffness, and decreased entropy of time to peak EMG in the gluteus maximus and lateral gastrocnemius under pivoting perturbations. Furthermore, the training group enhanced weight-bearing proprioceptive acuity and improved the single leg hop distance. Improvement of pivoting neuromuscular control in functional weight-bearing activities and task performances after POINT may help develop lower limb injury prevention and rehabilitation methods to reduce anterior cruciate ligament and other musculoskeletal injuries associated with pivoting sports.
Effects of Pivoting Neuromuscular Training on Pivoting Control and Proprioception
Lee, Song Joo; Ren, Yupeng; Chang, Alison H.; Geiger, François; Zhang, Li-Qun
2014-01-01
Purpose Pivoting neuromuscular control and proprioceptive acuity may play an important role in ACL injuries. The goal of this study was to investigate whether pivoting neuromuscular training on an offaxis elliptical trainer (POINT) could improve pivoting neuromuscular control, proprioceptive acuity, and functional performance. Methods Among 41 subjects, 21 subjects participated in 18 sessions of POINT (3 sessions/week for 6 weeks), and 20 subjects served as controls who did their regular workout. Both groups received pre-, mid-, and post-intervention evaluations. Propensity score analysis with multivariable regression adjustment was used to investigate the effect of training on pivoting neuromuscular control (pivoting instability, leg pivoting stiffness, maximum internal and external pivoting angles), proprioceptive acuity, and functional performance in both groups. Results Compared to the control group, the training group significantly improved pivoting neuromuscular control as reduced pivoting instability, reduced maximum internal and external pivoting angles, increased leg pivoting stiffness, and decreased entropy of time to peak EMG in the gluteus maximus and lateral gastrocnemius under pivoting perturbations. Furthermore, the training group enhanced weight-bearing proprioceptive acuity and improved the single leg hop distance. Conclusion Improvement of pivoting neuromuscular control in functional weight-bearing activities and task performances following POINT may help develop lower limb injury prevention and rehabilitation methods to reduce ACL and other musculoskeletal injuries associated with pivoting sports. PMID:24389517
ZAFFAGNINI, STEFANO; LOPOMO, NICOLA; SIGNORELLI, CECILIA; MUCCIOLI, GIULIO MARIA MARCHEGGIANI; BONANZINGA, TOMMASO; GRASSI, ALBERTO; RAGGI, FEDERICO; VISANI, ANDREA; MARCACCI, MAURILIO
2014-01-01
The main purpose of this article was to describe in detail, from the perspective of the clinical end user, a previously presented non-invasive methodology, applied in the treatment of anterior cruciate ligament injury, in which inertial sensors are used to quantify the pivot shift test. The outcomes obtained and relative considerations were compared with findings emerging from a review of the relevant updated literature. The detailed description here provided covers the system, the parameters identified and the testing procedure; it also includes the technical specifications of the hardware, the features introduced in the updated version of the software and the application of the system in clinical practice. The comparison of the technical considerations and clinical results with the updated literature confirmed the system’s optimal ergonomics, good reproducibility and clinical reliability. The novel approach here analyzed has been shown to overcome the weaknesses of other available devices and systems. Therefore, since it can be considered a new paradigm in the quantification of pivot shift test, we can recommend its routine use in clinical practice. PMID:25606555
Electro-mechanical heat switch for cryogenic applications
van den Berg, Marcel L.; Batteux, Jan D.; Labov, Simon E.
2003-01-01
A heat switch includes two symmetric jaws. Each jaw is comprised of a link connected at a translatable joint to a flexible arm. Each arm rotates about a fixed pivot, and has an articulated end including a thermal contact pad connected to a heat sink. The links are joined together at a translatable main joint. To close the heat switch, a closing solenoid is actuated and forces the main joint to an over-center position. This movement rotates the arms about their pivots, respectively, forces each of them into a stressed configuration, and forces the thermal contact pads towards each other and into compressive contact with a cold finger. The closing solenoid is then deactivated. The heat switch remains closed due to a restoring force generated by the stressed configuration of each arm, until actuation of an opening solenoid returns the main joint to its starting open-switch position.
Ergonomically neutral arm support system
Siminovitch, Michael J; Chung, Jeffrey Y; Dellinges, Steven; Lafever, Robin E
2005-08-02
An ergonomic arm support system maintains a neutral position for the forearm. A mechanical support structure attached to a chair or other mounting structure supports the arms of a sitting or standing person. The system includes moving elements and tensioning elements to provide a dynamic balancing force against the forearms. The support structure is not fixed or locked in a rigid position, but is an active dynamic system that is maintained in equipoise by the continuous operation of the opposing forces. The support structure includes an armrest connected to a flexible linkage or articulated or pivoting assembly, which includes a tensioning element such as a spring. The pivoting assembly moves up and down, with the tensioning element providing the upward force that balances the downward force of the arm.
AmeriFlux US-Ne1 Mead - irrigated continuous maize site
Suyker, Andy [University of Nebraska - Lincoln
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-Ne1 Mead - irrigated continuous maize site. Site Description - The study site is one of three fields (all located within 1.6 km of each other) at the University of Nebraska Agricultural Research and Development Center near Mead, Nebraska. This site is irrigated with a center pivot system. Prior to the initiation of the study, the irrigated site had a 10-yr history of maize-soybean rotation under no-till. A tillage operation (disking) was done just prior to the 2001 planting to homogenize the top 0.1 m of soil, incorporate P and K fertilizers, as well as previously accumulated surface residues. Since the tillage operation, the site has been under no-till management until the harvest of 2005. Following harvest, a conservation-plow tillage operation was initiated where a small amount of N fertilizer is sprayed on the residue immediately prior to the plow operation. Approximately 1/3 of the crop residue is left on the surface. The post-harvest conservation-plow operation continues as the current practice.
NASA Astrophysics Data System (ADS)
Budiman, M. A.; Zamzami, E. M.; Rachmawati, D.
2017-03-01
Dual-pivot quicksort, which was proposed by Yaroslavsky, has been experimentally proven to be more efficient than the classical single-pivot quicksort under the Java Virtual Machine [6]. Moreover, Kushagara, López-Ortiz, and Munro [4] has shown that triple-pivot quicksort runs 7-8% faster than dual-pivot quicksort in C, mutatis mutandis. In this research, we implement and experiment with single, dual, triple, quad, and penta-pivot quicksort algorithms in Python. Our experimental results are as follows. Firstly, the quicksort with single pivot is the slowest among the five variants. Secondly, at least until five (penta) pivots are being used, it is proven that the more pivots are used in a quicksort algorithm, the faster its performance becomes. Thirdly, the increase of speed resulted by adding more pivots tends to decrease gradually.
Airborne tracking sunphotometer apparatus and system
NASA Technical Reports Server (NTRS)
Matsumoto, Yutaka (Inventor); Mina, Cesar (Inventor); Russell, Philip B. (Inventor); Vanark, William B. (Inventor)
1987-01-01
An airborne tracking Sun photometer apparatus has a rotatable dome. An azimuth drive motor is connected to rotate the dome. The dome has an equatorial slot. A cylindrical housing is pivotally mounted inside the dome at the equatorial slot. A photometer is mounted in the housing to move in the equatorial slot as the housing pivots. The photometer has an end facing from the slot with an optical flat transparent window. An elevation drive motor is connected to pivot the cylindrical housing. The rotatable dome is mounted in the bulkhead of an aircraft to extend from the interior of the aircraft. A Sun sensor causes the photometer to track the Sun automatically. Alternatively, the photometer may be oriented manually or by computer.
Pivoting neuromuscular control and proprioception in females and males.
Lee, Song Joo; Ren, Yupeng; Kang, Sang Hoon; Geiger, François; Zhang, Li-Qun
2015-04-01
Noncontact ACL injuries occur most commonly in pivoting sports and are much more frequent in females than in males. However, information on sex differences in proprioceptive acuity under weight-bearing and leg neuromuscular control in pivoting is scarce. The objective of this study was to investigate sex differences in pivoting neuromuscular control during strenuous stepping tasks and proprioceptive acuity under weight-bearing. 21 male and 22 female subjects were recruited to evaluate pivoting proprioceptive acuity under weight-bearing, and pivoting neuromuscular control (in terms of leg pivoting instability, stiffness, maximum internal and external pivoting angles, and entropy of time-to-peak EMG in lower limb muscles) during strenuous stepping tasks performed on a novel offaxis elliptical trainer. Compared to males, females had significantly lower proprioceptive acuity under weight-bearing in both internal and external pivoting directions, higher pivoting instability, larger maximum internal pivoting angle, lower leg pivoting stiffness, and higher entropy of time-to-peak EMG in the gastrocnemius muscles during strenuous stepping tasks with internal and external pivoting perturbations. Results of this study may help us better understand factors contributing to ACL injuries in females and males, develop training strategies to improve pivoting neuromuscular control and proprioceptive acuity, and potentially reduce ACL and lower-limb musculoskeletal injuries.
NASA Astrophysics Data System (ADS)
Feng, Jianzhong; Bai, Linyan; wang, Kui; Zhang, Xuefu; Xie, Nengfu; Ran, Qiyun; Guo, Mingqiu; Xu, Lijun
2017-02-01
As China promotes the Belt and Road (BAR) initiative, the overland SREB development is widely concerned. The cities (including towns), population centers, of urban system are the cores of the economy along the SREB. Therefore, it is necessary to monitoring the urbanization of the belt so that the new growing points of urban development and the valid coupling mechanism between human and nature will be explored to promote the regional socio-economic sustainable development and effectively implement the BAR initiative. Using the DMSP-OLS stable nighttime lights (NTL) data in 1992, 2003, and 2014, in this paper we studied the urbanized spatial patterns of and the urbanized characteristics and trends of the main city system along the SREB in the view of the whole regionalized economic zone and typical cities and settlements (towns). The results showed that in general the NTL intensities in the SREB’s city system had the obvious geographical differentiation characteristics where there was maximum brightness of NTLs over the western European countries as well as being gradually decreasing from west to east. There were obvious increases of the NTL digital number (DN) values and NTL covering areas in 2003 and 2013 comparatively with that of 1992, which indicates the great urbanization development during this period. As for the four types of urban development process, there was an apparent consistency in a certain local area but a large heterogeneity among different areas. By analyzing the 273 pivot cities and the most pivot 26 cities, we found the number of the relatively small cities being decreasing but that of the large and medium-sized cities increasing. This study would provide the scientific support for the related researches and decision making of urbanization and urban economic development to promote the socio-economic comprehensive development of the overland SREB.
Communicating climate sciences in academia and beyond
NASA Astrophysics Data System (ADS)
Dupigny-Giroux, L. L.
2008-12-01
Climate change has catapulted climate and atmospheric sciences onto center stage in a way that eclipses the challenges of acid rain deposition in the late 1990s. However, there are subtle differences in the non- scientists' understanding of climate dynamics, processes, feedbacks etc.. Even among non-atmospheric scientists, there is sometimes an under-appreciation of the nuances of the land-atmosphere-ocean system. Many agencies are poised to play pivotal roles in helping to move this understanding forward, either due to their scientific missions or outreach components. Among these are the American Association of State Climatologists, the American Meteorological Society, American Geophysical Union, UCAR, NOAA, NASA and Association of American Geographers to name a few. This presentation will suggest directions in communicating climate science that come out a State Climatologist's perspective as well as liberal arts academic setting.
Motion systems providing three or four degrees of freedom
NASA Technical Reports Server (NTRS)
Chou, Richard C. (Inventor)
1982-01-01
A motion system is provided by a platform generally parallel to a base and connected thereto by a column and powered and controlled extensible members, at least three of which are connected between distributed points around the column. In a three degree of freedom device, the column is conical, rigidly supported at its base with a universal joint at its top. The points of attachment define triangles in the base and in the platform surrounding the column with one extensible member connected between each. In the four degree of freedom version, the column is modified by making it effectively a column which is pivoted or guided at the base or contains an extensible member, preferably retains its triangular shape and its universal joint connection to the platform at its apex. For stability four powered and controlled extensible members are provided between points in the base and platform distributed around the column, a preferred pattern of arrangement being a square with the column at the center.
28. VIEW EAST FROM DECKING ON SOUTHWEST CORNER OF PIVOT ...
28. VIEW EAST FROM DECKING ON SOUTHWEST CORNER OF PIVOT PIER, DRIVE SYSTEM FOR SWING-SPAN INCLUDES: (from left to right) ELECTRIC LINE FROM SHORE (bottom left), TRACK AND RAIL ON CONCRETE PIER, ELECTRIC MOTOR, GASOLINE MOTOR, SHAFTS TO WEDGE DRIVE CRANKS, WEDGE DRIVE DRIVE SHAFT, WEDGE DRIVE GEAR BOX, AND (on right) GEARING FOR MANUAL WEDGE DRIVE ACCESSED THROUGH BRIDGE DECK - Tipers Bridge, Spanning Great Wicomico River at State Route 200, Kilmarnock, Lancaster County, VA
Multi-access laser communications transceiver system
NASA Technical Reports Server (NTRS)
Ross, Monte (Inventor); Lokerson, Donald C. (Inventor); Fitzmaurice, Michael W. (Inventor); Meyer, Daniel D. (Inventor)
1993-01-01
A satellite system for optical communications such as a multi-access laser transceiver system. Up to six low Earth orbiting satellites send satellite data to a geosynchronous satellite. The data is relayed to a ground station at the Earth's surface. The earth pointing geosynchronous satellite terminal has no gimbal but has a separate tracking mechanism for tracking each low Earth orbiting satellite. The tracking mechanism has a ring assembly rotatable about an axis coaxial with the axis of the field of view of the geosynchronous satellite and a pivotable arm mounted for pivotal movement on the ring assembly. An optical pickup mechanism at the end of each arm is positioned for optical communication with one of the orbiting satellites by rotation of the ring.
Irrigated Agriculture, Saudi Arabia
NASA Technical Reports Server (NTRS)
1990-01-01
In Saudi Arabia, center-pivot, swing-arm irrigated agriculture complexes such as the one imaged at Jabal Tuwayq (20.5N, 45.0 E) extract deep fossil water reserves to achieve food crop production self sufficiency in this desert environment. The significance of the Saudi expanded irrigated agriculture is that the depletion of this finite water resource is a short term solution to a long term need that will still exist when the water has been extracted.
Irrigated Agriculture, Saudi Arabia
1990-01-20
In Saudi Arabia, center-pivot, swing-arm irrigated agriculture complexes such as the one imaged at Jabal Tuwayq (20.5N, 45.0 E) extract deep fossil water reserves to achieve food crop production self sufficiency in this desert environment. The significance of the Saudi expanded irrigated agriculture is that the depletion of this finite water resource is a short term solution to a long term need that will still exist when the water has been extracted.
NASA Technical Reports Server (NTRS)
Bickler, Donald B. (Inventor)
1989-01-01
The invention provides a rough terrain vehicle which maintains a substantially constant weight, and therefore traction, on all wheels, despite one wheel moving considerably higher or lower than the others, while avoiding a very soft spring suspension. The vehicle includes a chassis or body to be supported and a pair of side suspensions at either side of the body. In a six wheel vehicle, each side suspension includes a middle wheel, and front and rear linkages respectively coupling the front and rear wheels to the middle wheel. A body link pivotally connects the front and rear linkages together, with the middle of the body link rising or falling by only a fraction of the rise or fall of any of the three wheels. The body link pivotally supports the middle of the length of the body. A transverse suspension for suspending the end of the body on the side suspensions includes a middle part pivotally connected to the body about a longitudinal axis and opposite ends each pivotally connected to one of the side suspensions along at least a longitudinal axis.
Sagittal focusing Laue monochromator
Zhong,; Zhong, Hanson [Stony Brook, NY; Jonathan, Hastings [Wading River, NY; Jerome, Kao [Stanford, CA; Chi-Chang, Lenhard [Setauket, NY; Anthony, Siddons [Medford, NY; David Peter, Zhong [Cutchogue, NY; Hui, [Coram, NY
2009-03-24
An x-ray focusing device generally includes a slide pivotable about a pivot point defined at a forward end thereof, a rail unit fixed with respect to the pivotable slide, a forward crystal for focusing x-rays disposed at the forward end of the pivotable slide and a rearward crystal for focusing x-rays movably coupled to the pivotable slide and the fixed rail unit at a distance rearward from the forward crystal. The forward and rearward crystals define reciprocal angles of incidence with respect to the pivot point, wherein pivoting of the slide about the pivot point changes the incidence angles of the forward and rearward crystals while simultaneously changing the distance between the forward and rearward crystals.
Plume, Russell W.
2003-01-01
In 1998, ground water was being pumped from about 420 production wells in the middle Humboldt River Basin for a variety of uses. Principal uses were for agriculture, industry, mining, municipal, and power plant purposes. This report presents a compilation of the number and types of production wells, areas irrigated by ground water, and ground-water use in 14 hydrographic areas of the middle Humboldt River Basin in 1998. Annual pumping records for production wells usually are reported to the Nevada Division of Water Resources. However, operators of irrigation wells are not consistently required to report annual pumpage. Daily power-consumption and pump-discharge rates measured at 20 wells during the 1998 irrigation season and total power use at each well were used to estimate the amount of water, in feet of depth, applied to 20 alfalfa fields. These fields include about 10 percent of the total area, 36,700 acres, irrigated with ground water in the middle Humboldt River Basin. In 1998 an average of 2.0 feet of water was applied to 14 fields irrigated using center-pivot sprinkler systems, and an average of 2.6 feet of water was applied to 6 fields irrigated using wheel-line sprinkler systems. A similar approach was used to estimate the amount of water pumped at three wells using pumps powered by diesel engines. The two fields served by these three wells received 3.9 feet of water by flood irrigation during the 1998 irrigation season. The amount of water applied to the fields irrigated by center-pivot and wheel-line irrigation systems during the 1998 irrigation season was less than what would have been applied during a typical irrigation season because late winter and spring precipitation exceeded long-term monthly averages by as much as four times. As a result, the health of crops was affected by over-saturated soils, and most irrigation wells were only used sporadically in the first part of the irrigation season. Power consumption at 19 of the 20 wells in the 1994-97 irrigation seasons was 110 to 235 percent of the power consumption in the 1998 irrigation season. If the amount of water applied to fields during the 1998 irrigation season were adjusted to account for these differences in power consumption, the average amount of water applied to a field during a typical season using center-pivot and wheel-line sprinkler systems would be 3.1 feet and 3.7 feet, respectively. Total ground water pumped in the middle Humboldt River Basin during 1998 was about 298,000 acre-feet. This pumpage was distributed as follows: 78 percent for mining, 19 percent for irrigation, and 3 percent for industrial, municipal, and power plants combined. Mining pumpage is by far the largest source of ground-water use because several large gold mines have extended below local ground-water levels and the area around each mine must be dewatered in order to maintain a dry and workable mine. Total mining pumpage in 1998 was 233,000 acre-feet, of this total, 23,600 acre-feet was for consumptive use and 209,000 acre-feet was for dewatering eight mines. Excess water from the mines being dewatered was distributed as follows: 74,500 acre-feet was returned to aquifers by infiltration; 33,100 acre-feet was used for irrigation and for consumptive use at two mines and a power plant; 96,700 acre-feet was released to the Humboldt River or one of its tributaries; and 5,260 acre-feet was lost to evaporation.
NASA Technical Reports Server (NTRS)
Mendell, Wendell
1990-01-01
The author relates the history of the human exploration initiative from a personal perspective from the 1961 J. F. Kennedy initiative to land a man on the moon up to 1986 when a memo was circulated from NASA Headquarters to its employees which stated as a major goal the expansion of the human presence beyond Earth into the solar system. The pivotal role of life support research is woven into this personalized history.
Giotis, D; Paschos, N K; Zampeli, F; Pappas, E; Mitsionis, G; Georgoulis, A D
2016-09-01
Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee. Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control. Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P≤0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230). Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft. Level III, case-control therapeutic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Kim, Young-Hoo; Yoon, Sung-Hwan; Kim, Jun-Shik
2009-02-01
Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing prosthesis than in those with a PFC Sigma mobile-bearing prosthesis. We compared the results of 92 patients who had a Medial Pivot fixed-bearing prosthesis implanted in one knee and a PFC Sigma mobile-bearing prosthesis implanted in the other. There were 85 women and seven men with a mean age of 69.5 years (range, 55-81 years). The minimum followup was 2 years (mean, 2.6 years; range, 2-3 years). The patients were assessed clinically and radiographically using the rating systems of the Hospital for Special Surgery and the Knee Society at 3 months, 1 year, and annually thereafter. Contrary to expectations, we found worse early clinical outcomes, smaller ranges of knee motion, less patient satisfaction, and a higher complication rate for the Medial Pivot fixed-bearing prosthesis than for the PFC Sigma mobile-bearing prosthesis. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
A space efficient flexible pivot selection approach to evaluate determinant and inverse of a matrix.
Jafree, Hafsa Athar; Imtiaz, Muhammad; Inayatullah, Syed; Khan, Fozia Hanif; Nizami, Tajuddin
2014-01-01
This paper presents new simple approaches for evaluating determinant and inverse of a matrix. The choice of pivot selection has been kept arbitrary thus they reduce the error while solving an ill conditioned system. Computation of determinant of a matrix has been made more efficient by saving unnecessary data storage and also by reducing the order of the matrix at each iteration, while dictionary notation [1] has been incorporated for computing the matrix inverse thereby saving unnecessary calculations. These algorithms are highly class room oriented, easy to use and implemented by students. By taking the advantage of flexibility in pivot selection, one may easily avoid development of the fractions by most. Unlike the matrix inversion method [2] and [3], the presented algorithms obviate the use of permutations and inverse permutations.
Regional Security Cooperation in the Maghreb and Sahel: Algeria’s Pivotal Ambivalence
2012-02-01
between Colombian drug traffickers and AQIM, represented by Abdelkarim Targui, known as “the Tuareg,” held in Guinea Bissau in late October 2010.1...AND ADDRESS(ES) National Defense University,Africa Center for Strategic Studies,300 Fifth Avenue, Building 21, Fort Lesley J . McNair,Washington,DC...Ambassador William M. Bellamy (Ret.) National Defense University 300 Fifth Avenue, Building 21 Fort Lesley J . McNair Washington, DC 20319-5066 Phone
NASA Technical Reports Server (NTRS)
Vest, Thomas W. (Inventor); Carden, James R. (Inventor); Norton, William E. (Inventor); Belcher, Jewell G. (Inventor)
1992-01-01
A prosthetic device for below-the-elbow amputees, having a C-shaped clamping mechanism for grasping cylindrical objects, is described. The clamping mechanism is pivotally mounted to a cuff that fits on the amputee's lower arm. The present invention is utilized by placing an arm that has been amputated below the elbow into the cuff. The clamping mechanism then serves as a hand whenever it becomes necessary for the amputee to grasp a cylindrical object such as a handle, a bar, a rod, etc. To grasp the cylindrical object, the object is jammed against the opening in the C-shaped spring, causing the spring to open, the object to pass to the center of the spring, and the spring to snap shut behind the object. Various sizes of clamping mechanisms can be provided and easily interchanged to accommodate a variety of diameters. With the extension that pivots and rotates, the clamping mechanism can be used in a variety of orientations. Thus, this invention provides the amputee with a clamping mechanism that can be used to perform a number of tasks.
Venkataraman, Archana; Yang, Daniel Y-J; Dvornek, Nicha; Staib, Lawrence H; Duncan, James S; Pelphrey, Kevin A; Ventola, Pamela
2016-09-28
Behavioral interventions for autism have gained prominence in recent years; however, the neural-systems-level targets of these interventions remain poorly understood. We use a novel Bayesian framework to extract network-based differences before and after a 16-week pivotal response treatment (PRT) regimen. Our results suggest that the functional changes induced by PRT localize to the posterior cingulate and are marked by a shift in connectivity from the orbitofrontal cortex to the occipital-temporal cortex. Our results illuminate a potential PRT-induced learning mechanism, whereby the neural circuits involved during social perception shift from sensory and attentional systems to higher-level object and face processing areas.
Venkataraman, Archana; Yang, Daniel Y.-J.; Dvornek, Nicha; Staib, Lawrence H.; Duncan, James S.; Pelphrey, Kevin A.; Ventola, Pamela
2016-01-01
Behavioral interventions for autism have gained prominence in recent years; however, the neural-systems-level targets of these interventions remain poorly understood. We use a novel Bayesian framework to extract network-based differences before and after a 16-week Pivotal Response Treatment (PRT) regimen. Our results suggest that functional changes induced by PRT localize to the posterior cingulate and are marked by a shift in connectivity from the orbitofrontal cortex to the occipital temporal cortex. Our results illuminate a potential PRT-induced learning mechanism, whereby the neural circuits involved during social perception shift from sensory and attentional systems to higher-level object and face processing areas. PMID:27532879
Development of the CLAES instrument aperture door system
NASA Technical Reports Server (NTRS)
Stubbs, D. M.
1990-01-01
The design, assembly, and test processes followed in developing a space-qualified aperture door system are described. A blackbody calibration source is mounted inside the door, requiring the assembly to open and close a minimum of 150 cycles for instrument recalibration. Within the door system are four separate mechanisms, three of which are redundant; a pyro launch latch, a hinge bearing assembly, and a pair of pivot mechanisms. Decoupling devices within the pivot mechanisms allow an active drive unit to automatically overdrive a failed drive unit. The door is also stowable for possible Shuttle retrieval and re-entry. Illustrations and photographs of the flight hardware help acquaint the reader with the design. The aim is to pass on lessons learned in all phases of developing this spaceflight mechanism.
Logerstedt, David; Arundale, Amelia; Lynch, Andrew; Snyder-Mackler, Lynn
2015-01-01
Injuries to the knee, including intra-articular fractures, ligamentous ruptures, and meniscal and articular cartilage lesions, are commonplace within sports. Despite advancements in surgical techniques and enhanced rehabilitation, athletes returning to cutting, pivoting, and jumping sports after a knee injury are at greater risk of sustaining a second injury. The clinical utility of objective criteria presents a decision-making challenge to ensure athletes are fully rehabilitated and safe to return to sport. A system centered on specific indicators that can be used to develop a comprehensive profile to monitor rehabilitation progression and to establish return to activity criteria is recommended to clear athletes to begin a progressive and systematic approach to activities and sports. Integration of a sports knee injury performance profile with return to activity criteria can guide clinicians in facilitating an athlete's safe return to sport, prevention of subsequent injury, and life-long knee joint health.
Method and apparatus for deflection measurements using eddy current effects
NASA Astrophysics Data System (ADS)
Chern, Engmin J.
1993-05-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
NASA Technical Reports Server (NTRS)
Drew, J. V. (Principal Investigator); Seevers, P. M.
1974-01-01
The author has identified the following significant results. Interpretations of imagery from the Earth Resources Technology Satellite (ERTS-1) indicate that soil associations and attendant range sites can be identified on the basis of vegetation and topography using multitemporal imagery. Optical density measurements of imagery from the visible red band of the multispectral scanner(MSS band 5) obtained during the growing season were related to field measurements of vegetative biomass, a factor that closely parallels range condition class on specific range sites. ERTS-1 imagery also permitted inventory and assessment of center-pivot irrigation systems in the Sand Hills region in relation to soil and topographic conditions and energy requirements. Four resource maps of the Upper Loup Natural Resource District located entirely within the Sand Hills region were prepared from ERTS-1 imagery.
Method and apparatus for deflection measurements using eddy current effects
NASA Technical Reports Server (NTRS)
Chern, Engmin J. (Inventor)
1993-01-01
A method and apparatus for inserting and moving a sensing assembly with a mechanical positioning assembly to a desired remote location of a surface of a specimen under test and measuring angle and/or deflection by sensing the change in the impedance of at least one sensor coil located in a base plate which has a rotatable conductive plate pivotally mounted thereon so as to uncover the sensor coil(s) whose impedance changes as a function of deflection away from the center line of the base plate in response to the movement of the rotator plate when contacting the surface of the specimen under test is presented. The apparatus includes the combination of a system controller, a sensing assembly, an eddy current impedance measuring apparatus, and a mechanical positioning assembly driven by the impedance measuring apparatus to position the sensing assembly at a desired location of the specimen.
Logerstedt, David; Arundale, Amelia; Lynch, Andrew; Snyder-Mackler, Lynn
2015-01-01
Injuries to the knee, including intra-articular fractures, ligamentous ruptures, and meniscal and articular cartilage lesions, are commonplace within sports. Despite advancements in surgical techniques and enhanced rehabilitation, athletes returning to cutting, pivoting, and jumping sports after a knee injury are at greater risk of sustaining a second injury. The clinical utility of objective criteria presents a decision-making challenge to ensure athletes are fully rehabilitated and safe to return to sport. A system centered on specific indicators that can be used to develop a comprehensive profile to monitor rehabilitation progression and to establish return to activity criteria is recommended to clear athletes to begin a progressive and systematic approach to activities and sports. Integration of a sports knee injury performance profile with return to activity criteria can guide clinicians in facilitating an athlete's safe return to sport, prevention of subsequent injury, and life-long knee joint health. PMID:26537805
Crew Earth Observations (CEO) taken during Expedition Five on the ISS
2002-08-17
ISS005-E-9984 (17 August 2002) --- This digital still photograph, taken from the International Space Station (ISS) during its fifth staffing, depicts both agriculture and the petroleum industry, which compete for land use near Denver City, Texas. The photo was recently released by the Earth Sciences and Image Analysis Laboratory at Johnson Space Center. The area is southwest of Lubbock near the New Mexico border. According to analysts studying the station imagery, the economy of this region is almost completely dependent on its underground resources of petroleum and water. Both resources result in distinctive land use patterns visible from space. Historically this area has produced vast quantities of oil and gas since development began in the 1930s. A fine, light-colored grid of roads and pipelines connect well sites over this portion of the Wasson Oil Field, one of the states most productive. Since the 1940s, agricultural land use has shifted from grazing to irrigated cultivation of cotton, sorghum, wheat, hay, and corn. The water supply is drawn from wells tapping the vast Ogallala Aquifer. Note the large, circular center-pivot irrigation systems in the lower corners of the image. The largest is nearly a mile in diameter.
Wang, G; Wu, K; Hu, H; Li, G; Wang, L J
2016-10-01
To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.
NASA Astrophysics Data System (ADS)
Wang, G.; Wu, K.; Hu, H.; Li, G.; Wang, L. J.
2016-10-01
To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.
Degree-based statistic and center persistency for brain connectivity analysis.
Yoo, Kwangsun; Lee, Peter; Chung, Moo K; Sohn, William S; Chung, Sun Ju; Na, Duk L; Ju, Daheen; Jeong, Yong
2017-01-01
Brain connectivity analyses have been widely performed to investigate the organization and functioning of the brain, or to observe changes in neurological or psychiatric conditions. However, connectivity analysis inevitably introduces the problem of mass-univariate hypothesis testing. Although, several cluster-wise correction methods have been suggested to address this problem and shown to provide high sensitivity, these approaches fundamentally have two drawbacks: the lack of spatial specificity (localization power) and the arbitrariness of an initial cluster-forming threshold. In this study, we propose a novel method, degree-based statistic (DBS), performing cluster-wise inference. DBS is designed to overcome the above-mentioned two shortcomings. From a network perspective, a few brain regions are of critical importance and considered to play pivotal roles in network integration. Regarding this notion, DBS defines a cluster as a set of edges of which one ending node is shared. This definition enables the efficient detection of clusters and their center nodes. Furthermore, a new measure of a cluster, center persistency (CP) was introduced. The efficiency of DBS with a known "ground truth" simulation was demonstrated. Then they applied DBS to two experimental datasets and showed that DBS successfully detects the persistent clusters. In conclusion, by adopting a graph theoretical concept of degrees and borrowing the concept of persistence from algebraic topology, DBS could sensitively identify clusters with centric nodes that would play pivotal roles in an effect of interest. DBS is potentially widely applicable to variable cognitive or clinical situations and allows us to obtain statistically reliable and easily interpretable results. Hum Brain Mapp 38:165-181, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
F-8 oblique wing structural feasibility study
NASA Technical Reports Server (NTRS)
Koltko, E.; Katz, A.; Bell, M. A.; Smith, W. D.; Lauridia, R.; Overstreet, C. T.; Klapprott, C.; Orr, T. F.; Jobe, C. L.; Wyatt, F. G.
1975-01-01
The feasibility of fitting a rotating oblique wing on an F-8 aircraft to produce a full scale manned prototype capable of operating in the transonic and supersonic speed range was investigated. The strength, aeroelasticity, and fatigue life of such a prototype are analyzed. Concepts are developed for a new wing, a pivot, a skewing mechanism, control systems that operate through the pivot, and a wing support assembly that attaches in the F-8 wing cavity. The modification of the two-place NTF-8A aircraft to the oblique wing configuration is discussed.
NASA Technical Reports Server (NTRS)
Nemeth, Z. N.
1972-01-01
Rotor bearing dynamic tests were conducted with tilting-pad journal bearings having three different pad masses and two different pivot geometries. The rotor was vertically mounted and supported by two three-pad tilting-pad gas journal bearings and a simple externally pressurized thrust bearing. The bearing pads were 5.1 cm (2.02 in.) in diameter and 2.8 cm (1.5 in.) long. The length to diameter ratio was 0.75. One pad was mounted on a flexible diaphragm. The bearing supply pressure ranged from 0 to 690 kilonewtons per square meter (0 to 100 psig), and speeds ranged to 38,500 rpm. Heavy mass pad tilting-pad assemblies produced three rotor-bearing resonances above the first two rotor critical speeds. Lower supply pressure eliminated the resonances. The resonances were oriented primarily in the direction normal to the diaphragm.
Regulating biopharmaceuticals under CDER versus CBER: an insider's perspective.
Schwieterman, William D
2006-10-01
The FDA has recently transferred jurisdiction for the regulation of certain biopharmaceuticals from the Center for Biologics, Evaluation and Research to the Center for Drugs, Evaluation and Research, where they will be reviewed in the same FDA divisions as are traditional pharmaceutical agents. With this transfer, sponsors of investigational biopharmaceuticals should expect changes in the regulatory requirements the FDA imposes on the clinical development plans, including an increase in the size and number of pivotal studies; more consistent requirements for conducting preclinical tests in two animal species; increased emphasis on organ structure and function as components of primary endpoints; more emphasis on characterizing dose-ranging and pharmacology; more intense scrutinizing of product advertising; and decreased direct communication with the review team.
Shigeno, Shuichi; Ogura, Atsushi; Mori, Tsukasa; Toyohara, Haruhiko; Yoshida, Takao; Tsuchida, Shinji; Fujikura, Katsunori
2014-01-01
Deep-sea alvinellid worm species endemic to hydrothermal vents, such as Alvinella and Paralvinella, are considered to be among the most thermotolerant animals known with their adaptability to toxic heavy metals, and tolerance of highly reductive and oxidative stressful environments. Despite the number of recent studies focused on their overall transcriptomic, proteomic, and metabolic stabilities, little is known regarding their sensory receptor cells and electrically active neuro-processing centers, and how these can tolerate and function in such harsh conditions. We examined the extra- and intracellular organizations of the epidermal ciliated sensory cells and their higher centers in the central nervous system through immunocytochemical, ultrastructural, and neurotracing analyses. We observed that these cells were rich in mitochondria and possessed many electron-dense granules, and identified specialized glial cells and serial myelin-like repeats in the head sensory systems of Paralvinella hessleri. Additionally, we identified the major epidermal sensory pathways, in which a pair of distinct mushroom bodies-like or small interneuron clusters was observed. These sensory learning and memory systems are commonly found in insects and annelids, but the alvinellid inputs are unlikely derived from the sensory ciliary cells of the dorsal head regions. Our evidence provides insight into the cellular and system-wide adaptive structure used to sense, process, and combat the deep-sea hydrothermal vent environment. The alvinellid sensory cells exhibit characteristics of annelid ciliary types, and among the most unique features were the head sensory inputs and structure of the neural cell bodies of the brain, which were surrounded by multiple membranes. We speculated that such enhanced protection is required for the production of normal electrical signals, and to avoid the breakdown of the membrane surrounding metabolically fragile neurons from oxidative stress. Such pivotal acquisition is not broadly found in the all body parts, suggesting the head sensory inputs are specific, and these heterogenetic protection mechanisms may be present in alvinellid worms.
N-Dimensional LLL Reduction Algorithm with Pivoted Reflection
Deng, Zhongliang; Zhu, Di
2018-01-01
The Lenstra-Lenstra-Lovász (LLL) lattice reduction algorithm and many of its variants have been widely used by cryptography, multiple-input-multiple-output (MIMO) communication systems and carrier phase positioning in global navigation satellite system (GNSS) to solve the integer least squares (ILS) problem. In this paper, we propose an n-dimensional LLL reduction algorithm (n-LLL), expanding the Lovász condition in LLL algorithm to n-dimensional space in order to obtain a further reduced basis. We also introduce pivoted Householder reflection into the algorithm to optimize the reduction time. For an m-order positive definite matrix, analysis shows that the n-LLL reduction algorithm will converge within finite steps and always produce better results than the original LLL reduction algorithm with n > 2. The simulations clearly prove that n-LLL is better than the original LLL in reducing the condition number of an ill-conditioned input matrix with 39% improvement on average for typical cases, which can significantly reduce the searching space for solving ILS problem. The simulation results also show that the pivoted reflection has significantly declined the number of swaps in the algorithm by 57%, making n-LLL a more practical reduction algorithm. PMID:29351224
What does it take to have a high-grade pivot shift?
Tanaka, M; Vyas, D; Moloney, G; Bedi, A; Pearle, A D; Musahl, V
2012-04-01
The pivot shift is the most specific clinical test to assess pathological knee joint rotatory laxity following ACL injury. This article attempts to describe the anatomic structures responsible for creating a high-grade pivot shift and their potential role in customizing ACL reconstruction. A review of the literature demonstrates that disruption of the secondary stabilizers of anterior translation of the lateral compartment including the lateral meniscus, anterolateral capsule, and IT band contributes to a high-grade pivot shift in the ACL-deficient knee. The morphology of the lateral tibial plateau, including increased posteroinferior tibial slope and small size, can also contribute to high-grade pivot shift. Factors that may decrease the grade of the pivot shift include medial compartment injury, MCL injury, patient guarding, and osteoarthritis. In conclusion, a high-grade pivot shift in the ACL-deficient knee is often associated with incompetence of the lateral soft tissue envelope. Rotatory laxity as assessed by the pivot shift may also be falsely underestimated by concomitant injuries. IV.
Development of a Passively Varying Pitch Propeller
NASA Astrophysics Data System (ADS)
Heinzen, Stearns Beamon
Small general aviation aircraft and unmanned aerial systems are often equipped with sophisticated navigation, control, and other avionics, but retain propulsion systems consisting of retrofitted radio control and ultralight equipment. Consequently, new high performance airframes often rely on relatively primitive propulsive technology. This trend is beginning to shift with recent advances in small turboprop engines, fuel injected reciprocating engines, and improved electric technologies. Although these systems are technologically advanced, they are often paired with standard fixed pitch propellers. To fully realize the potential of these aircraft and the new generation of engines, small propellers which can efficiently transmit power over wide flight envelopes and a variety of power settings must be developed. This work demonstrates a propeller which passively adjusts to incoming airflow at a low penalty to aircraft weight and complexity. This allows the propeller to operate in an efficient configuration over a wide flight envelope, and can prevent blade stall in low-velocity / highly-loaded thrust cases and over-speeding at high flight speeds. The propeller incorporates blades which pivot freely on a radial axis and are aerodynamically tailored to attain and maintain a pitch angle yielding favorable local blade angles of attack, matched to changing inflow conditions. This blade angle is achieved through the use of reflexed airfoils designed for a positive pitching moment, comparable to those used on many tailless flying wings. By setting the axis of rotation at a point forward of the blade aerodynamic center, the blades will naturally adjust to a predetermined positive lift 'trim' condition. Then, as inflow conditions change, the blade angle will automatically pivot to maintain the same angle with respect to incoming air. Computational, wind tunnel, and flight test results indicate that the extent of efficient propeller operation can be increased dramatically as compared to the fixed pitch propellers currently used on most light aircraft and small unmanned systems, making significant improvements in aircraft performance possible. These improvements may yield aircraft with reduced takeoff distances, improved climb rates, increased range and endurance, and higher top speeds, without sacrificing on-design performance.
Thrust Stand for Vertically Oriented Electric Propulsion Performance Evaluation
NASA Technical Reports Server (NTRS)
Moeller, Trevor; Polzin, Kurt A.
2010-01-01
A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally-stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A non-contact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivots with oscillatory motion attenuated by a passive, eddy current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational restoring force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN-level thrusts, while those tests conducted on 200 lbm thruster yielded a resolution of roughly 2.5 micro at thrust levels of 0.5 N and greater.
Towards School Management System (SMS) Success in Teacher's Perception
ERIC Educational Resources Information Center
Hassan, Haslina binti; Rahmatullah, Bahbibi binti; Nordin, Norhisham bin Mohamad
2014-01-01
School Management System-SMS (Sistem Pengurusan Sekolah) is a system developed by Ministry of Education Malaysia in order to reduce teachers' burden and for Educational Data Integration. SMS is a type of Management Information System (MIS) and is pivotal for efficient and effective running of schools in Malaysia. As SMS is newly introduced, no…
NASA Astrophysics Data System (ADS)
Lu, Lyan-Ywan; Lin, Tzu-Kang; Jheng, Rong-Jie; Wu, Hsin-Hsien
2018-01-01
A semi-active friction damper (SAFD) can be employed for the seismic protection of structural systems. The effectiveness of an SAFD in absorbing seismic energy is usually superior to that of its passive counterpart, since its slip force can be altered in real time according to structural response and excitation. Most existing SAFDs are controlled by adjusting the clamping force applied on the friction interface. Thus, the implementation of SAFDs in practice requires precision control of the clamping force, which is usually substantially larger than the slip force. This may increase the implementation complexity and cost of SAFDs. To avoid this problem, this study proposes a novel position-controlled SAFD, named the leverage-type controllable friction damper (LCFD). The LCFD system combines a traditional passive friction damper and a leverage mechanism with a movable central pivot. By simply controlling the pivot position, the damping force generated by the LCFD system can be adjusted in real time. In order to verify the feasibility of the proposed SAFD, a prototype LCFD was tested by using a shaking table. The test results demonstrate that the equivalent friction force and hysteresis loop of the LCFD can be regulated by controlling the pivot position. By considering 16 ground motions with two different intensities, the adaptive feature of the LCFD for seismic structural control is further demonstrated numerically.
Brzoska, Tomasz; Tanaka-Murakami, Aki; Suzuki, Yuko; Sano, Hideto; Kanayama, Naohiro; Urano, Tetsumei
2015-01-01
The fibrinolytic system plays a pivotal role in the regulation of hemostasis; however, it remains unclear how and when the system is triggered to induce thrombolysis. Using intra-vital confocal fluorescence microscopy, we investigated the process of plasminogen binding to laser-induced platelet-rich microthrombi generated in the mesenteric vein of transgenic mice expressing green fluorescent protein (GFP). The accumulation of GFP-expressing platelets as well as exogenously infused Alexa Fluor 568-labeled Glu-plasminogen (Glu-plg) on the injured vessel wall was assessed by measuring the increase in the corresponding fluorescence intensities. Glu-plg accumulated in a time-dependent manner in the center of the microthrombus, where phosphatidylserine is exposed on platelet surfaces and fibrin formation takes place. The rates of binding of Glu-plg in the presence of ε-aminocaproic acid and carboxypeptidase B, as well as the rates of binding of mini-plasminogen lacking kringle domains 1-4 and lysine binding sites, were significantly lower than that of Glu-plg alone, suggesting that the binding was dependent on lysine binding sites. Furthermore, aprotinin significantly suppressed the accumulation of Glu-plg, suggesting that endogenously generated plasmin activity is a prerequisite for the accumulation. In spite of the endogenous generation of plasmin and accumulation of Glu-plg in the center of microthrombi, the microthrombi did not change in size during the 2-hour observation period. When human tissue plasminogen activator was administered intravenously, Glu-plg further accumulated and the microthrombi were lysed. Glu-plg appeared to accumulate in the center of microthrombi in the early phase of microthrombus formation, and plasmin activity and lysine binding sites were required for this accumulation. PMID:25806939
Smith, Richard W.
1979-01-01
An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.
Ghazi, Lama; Drawz, Paul
2017-01-01
The renin-angiotensin-aldosterone system (RAAS) plays a fundamental role in the physiology of blood pressure control and the pathophysiology of hypertension (HTN) with effects on vascular tone, sodium retention, oxidative stress, fibrosis, sympathetic tone, and inflammation. Fortunately, RAAS blocking agents have been available to treat HTN since the 1970s and newer medications are being developed. In this review, we will (1) examine new anti-hypertensive medications affecting the RAAS, (2) evaluate recent studies that help provide a better understanding of which patients may be more likely to benefit from RAAS blockade, and (3) review three recent pivotal randomized trials that involve newer RAAS blocking agents and inform clinical practice. PMID:28413612
Ghazi, Lama; Drawz, Paul
2017-01-01
The renin-angiotensin-aldosterone system (RAAS) plays a fundamental role in the physiology of blood pressure control and the pathophysiology of hypertension (HTN) with effects on vascular tone, sodium retention, oxidative stress, fibrosis, sympathetic tone, and inflammation. Fortunately, RAAS blocking agents have been available to treat HTN since the 1970s and newer medications are being developed. In this review, we will (1) examine new anti-hypertensive medications affecting the RAAS, (2) evaluate recent studies that help provide a better understanding of which patients may be more likely to benefit from RAAS blockade, and (3) review three recent pivotal randomized trials that involve newer RAAS blocking agents and inform clinical practice.
Performance and Kinematics of Various Throwing Techniques in Team-Handball
Wagner, Herbert; Pfusterschmied, Jürgen; von Duvillard, Serge P.; Müller, Erich
2011-01-01
In team-handball competition, the players utilize various throwing techniques that differ in the lower body movements (with and without run-up or jump). These different lower body movements influence changes in the upper body movements and thus also affect the performance. A comprehensive analysis of 3D-kinematics of team-handball throws that may explain these differences in performance is lacking. Consequently, the purpose of this study was (1) to compare performance (ball velocity and throwing accuracy) between the jump throw, standing throw with and without run-up, and the pivot throw; (2) to calculate the influence of kinematic parameters to ball velocity; and (3) to determine if these four throwing techniques differ significantly in kinematics. Three-dimensional kinematic data (angles, angular velocities and their timing, ball velocity and velocity of the center of mass) of 14 elite team-handball players were measured using an 8 camera Vicon MX13 motion capture system (Vicon, Oxford, UK), at 250 Hz. Significant difference was found between the four throwing techniques for ball velocity (p < 0. 001), maximal velocity of the center of mass in goal-directed movement (p < 0.001), and 15 additional kinematic variables (p < 0.003). Ball velocity was significant impacted by the run-up and the pelvis and trunk movements. Depending on floor contact (standing vs. jump throws), elite players in the study used two different strategies (lead leg braces the body vs. opposed leg movements during flight) to accelerate the pelvis and trunk to yield differences in ball velocity. However, these players were able to utilize the throwing arm similarly in all four throwing techniques. Key points Elite team-handball players achieved the greatest ball velocity in the standing throw with run-up (100%), followed by the standing throw without run-up (93%), jump throw (92%) and pivot throw (85%). Depending on the floor contact (standing vs. jump throws) the elite players of the study used two different strategies (lead leg braces the body vs. opposed leg movements during flight) to accelerate the pelvis and trunk that caused differences in ball velocity. Elite team-handball players were able to utilize the throwing arm similarly in all four throwing techniques. PMID:24149298
Wilt, Timothy J
2012-12-01
Prostate cancer is the most common noncutaneous malignancy and the second leading cause of cancer death in men. In the United States, 90% of men with prostate cancer are more than age 60 years, diagnosed by early detection with the prostate-specific antigen (PSA) blood test, and have disease believed confined to the prostate gland (clinically localized). Common treatments for clinically localized prostate cancer include watchful waiting (WW), surgery to remove the prostate gland (radical prostatectomy), external-beam radiation therapy and interstitial radiation therapy (brachytherapy), and androgen deprivation. Little is known about the relative effectiveness and harms of treatments because of the paucity of randomized controlled trials. The Department of Veterans Affairs/National Cancer Institute/Agency for Healthcare Research and Quality Cooperative Studies Program Study #407:Prostate Cancer Intervention Versus Observation Trial (PIVOT), initiated in 1994, is a multicenter randomized controlled trial comparing radical prostatectomy with WW in men with clinically localized prostate cancer. We describe the study rationale, design, recruitment methods, and baseline characteristics of PIVOT enrollees. We provide comparisons with eligible men declining enrollment and men participating in another recently reported randomized trial of radical prostatectomy vs WW conducted in Scandinavia. We screened 13 022 men with prostate cancer at 52 US medical centers for potential enrollment. From these, 5023 met initial age, comorbidity, and disease eligibility criteria, and a total of 731 men agreed to participate and were randomized. The mean age of enrollees was 67 years. Nearly one-third were African American. Approximately 85% reported that they were fully active. The median PSA was 7.8ng/mL (mean 10.2ng/mL). In three-fourths of men, the primary reason for biopsy leading to a diagnosis of prostate cancer was a PSA elevation or rise. Using previously developed tumor risk categorizations incorporating PSA levels, Gleason histologic grade, and tumor stage, it was found that approximately 40% had low-risk, 34% had medium-risk, and 21% had high-risk prostate cancer based on local histopathology. Comparison to our national sample of eligible men declining PIVOT participation as well as to men enrolled in the Scandinavian trial indicated that PIVOT enrollees are representative of men being diagnosed and treated in the United States and quite different from men in the Scandinavian trial. PIVOT enrolled an ethnically diverse population representative of men diagnosed with prostate cancer in the United States. Results will yield important information regarding the relative effectiveness and harms of surgery compared with WW for men with predominately PSA-detected clinically localized prostate cancer.
Wilt, Timothy J; Brawer, Michael K; Barry, Michael J; Jones, Karen M; Kwon, Young; Gingrich, Jeffrey R; Aronson, William J; Nsouli, Imad; Iyer, Padmini; Cartagena, Ruben; Snider, Glenn; Roehrborn, Claus; Fox, Steven
2009-01-01
Prostate cancer is the most common noncutaneous malignancy and the second leading cause of cancer death in men. Ninety percent of men with prostate cancer are over aged 60 years, diagnosed by early detection with the prostate specific antigen (PSA) blood test and have disease believed confined to the prostate gland (clinically localized). Common treatments for clinically localized prostate cancer include watchful waiting surgery to remove the prostate gland (radical prostatectomy), external beam radiation therapy and interstitial radiation therapy (brachytherapy) and androgen deprivation. Little is known about the relative effectiveness and harms of treatments due to the paucity of randomized controlled trials. The VA/NCI/AHRQ Cooperative Studies Program Study #407: Prostate cancer Intervention Versus Observation Trial (PIVOT), initiated in 1994, is a multicenter randomized controlled trial comparing radical prostatectomy to watchful waiting in men with clinically localized prostate cancer. We describe the study rationale, design, recruitment methods and baseline characteristics of PIVOT enrollees. We provide comparisons with eligible men declining enrollment and men participating in another recently reported randomized trial of radical prostatectomy versus watchful waiting conducted in Scandinavia. We screened 13,022 men with prostate cancer at 52 United States medical centers for potential enrollment. From these, 5023 met initial age, comorbidity and disease eligibility criteria and a total of 731 men agreed to participate and were randomized. The mean age of enrollees was 67 years. Nearly one-third were African-American. Approximately 85% reported they were fully active. The median prostate specific antigen (PSA) was 7.8 ng/mL (mean 10.2 ng/mL). In three-fourths of men the primary reason for biopsy leading to a diagnosis of prostate cancer was a PSA elevation or rise. Using previously developed tumor risk categorizations incorporating PSA levels, Gleason histologic grade and tumor stage, approximately 43% had low risk, 36% had medium risk and 20% had high-risk prostate cancer. Comparison to our national sample of eligible men declining PIVOT participation as well as to men enrolled in the Scandinavian trial indicated that PIVOT enrollees are representative of men being diagnosed and treated in the U.S. and quite different from men in the Scandinavian trial. PIVOT enrolled an ethnically diverse population representative of men diagnosed with prostate cancer in the United States. Results will yield important information regarding the relative effectiveness and harms of surgery compared to watchful waiting for men with predominately PSA detected clinically localized prostate cancer.
Parallel pivoting combined with parallel reduction
NASA Technical Reports Server (NTRS)
Alaghband, Gita
1987-01-01
Parallel algorithms for triangularization of large, sparse, and unsymmetric matrices are presented. The method combines the parallel reduction with a new parallel pivoting technique, control over generations of fill-ins and a check for numerical stability, all done in parallel with the work being distributed over the active processes. The parallel technique uses the compatibility relation between pivots to identify parallel pivot candidates and uses the Markowitz number of pivots to minimize fill-in. This technique is not a preordering of the sparse matrix and is applied dynamically as the decomposition proceeds.
USDA-ARS?s Scientific Manuscript database
A critical event in fetal development is the proper formation of the vascular system, of which the hepatobiliary system plays a pivotal role. This has lead pathologists and scientists to utilize transgenic mice to identify developmental disorders associated with the hepatobiliary vascular system. Va...
Nagai, Kanto; Hoshino, Yuichi; Nishizawa, Yuichiro; Araki, Daisuke; Matsushita, Takehiko; Matsumoto, Tomoyuki; Takayama, Koji; Nagamune, Kouki; Kurosaka, Masahiro; Kuroda, Ryosuke
2015-10-01
Tibial acceleration during the pivot shift test is a potential quantitative parameter to evaluate rotational laxity of anterior cruciate ligament (ACL) insufficiency. However, clinical application of this measurement has not been fully examined. This study aimed to measure and compare tibial acceleration before and after ACL reconstruction (ACLR) in ACL-injured patients. We hypothesized tibial acceleration would be reduced by ACLR and tibial acceleration would be consistent in the same knee at different time points. Seventy ACL-injured patients who underwent ACLR were enrolled. Tibial acceleration during the pivot shift test was measured using an electromagnetic measurement system before ALCR and at the second-look arthroscopy 1 year post-operatively. Tibial acceleration was compared to clinical grading and between ACL-injured/ACL-reconstructed and contralateral knees. Pre-operative tibial acceleration was increased stepwise with the increase in clinical grading (P < 0.01). Tibial acceleration in ACL-injured knee (1.9 ± 1.2 m/s(2)) was larger than that in the contralateral knee (0.8 ± 0.3 m/s(2), P < 0.01), and reduced to 0.9 ± 0.3 m/s(2) post-operatively (P < 0.01). There was no difference between ACL-reconstructed and contralateral knee (n.s.). Tibial acceleration in contralateral knees was consistent pre- and post-operatively (n.s.). Tibial acceleration measurement demonstrated increased rotational laxity in ACL-injured knees and its reduction by ALCR. Additionally, consistent measurements were obtained in ACL-intact knees at different time points. Therefore, tibial acceleration during the pivot shift test could provide quantitative evaluation of rotational stability before and after ACL reconstruction. III.
New insights into muscle function during pivot feeding in seahorses.
Van Wassenbergh, Sam; Dries, Billy; Herrel, Anthony
2014-01-01
Seahorses, pipefish and their syngnathiform relatives are considered unique amongst fishes in using elastic recoil of post-cranial tendons to pivot the head extremely quickly towards small crustacean prey. It is known that pipefish activate the epaxial muscles for a considerable time before striking, at which rotations of the head and the hyoid are temporarily prevented to allow energy storage in the epaxial tendons. Here, we studied the motor control of this system in seahorses using electromyographic recordings of the epaxial muscles and the sternohyoideus-hypaxial muscles with simultaneous high-speed video recordings of prey capture. In addition we present the results from a stimulation experiment including the muscle hypothesised to be responsible for the locking and triggering of pivot feeding in seahorses (m. adductor arcus palatini). Our data confirmed that the epaxial pre-activation pattern observed previously for pipefish also occurs in seahorses. Similar to the epaxials, the sternohyoideus-hypaxial muscle complex shows prolonged anticipatory activity. Although a considerable variation in displacements of the mouth via head rotation could be observed, it could not be demonstrated that seahorses have control over strike distance. In addition, we could not identify the source of the kinematic variability in the activation patterns of the associated muscles. Finally, the stimulation experiment supported the previously hypothesized role of the m. adductor arcus palatini as the trigger in this elastic recoil system. Our results show that pre-stressing of both the head elevators and the hyoid retractors is taking place. As pre-activation of the main muscles involved in pivot feeding has now been demonstrated for both seahorses and pipefish, this is probably a generalized trait of Syngnathidae.
New Insights into Muscle Function during Pivot Feeding in Seahorses
Van Wassenbergh, Sam; Dries, Billy; Herrel, Anthony
2014-01-01
Seahorses, pipefish and their syngnathiform relatives are considered unique amongst fishes in using elastic recoil of post-cranial tendons to pivot the head extremely quickly towards small crustacean prey. It is known that pipefish activate the epaxial muscles for a considerable time before striking, at which rotations of the head and the hyoid are temporarily prevented to allow energy storage in the epaxial tendons. Here, we studied the motor control of this system in seahorses using electromyographic recordings of the epaxial muscles and the sternohyoideus-hypaxial muscles with simultaneous high-speed video recordings of prey capture. In addition we present the results from a stimulation experiment including the muscle hypothesised to be responsible for the locking and triggering of pivot feeding in seahorses (m. adductor arcus palatini). Our data confirmed that the epaxial pre-activation pattern observed previously for pipefish also occurs in seahorses. Similar to the epaxials, the sternohyoideus-hypaxial muscle complex shows prolonged anticipatory activity. Although a considerable variation in displacements of the mouth via head rotation could be observed, it could not be demonstrated that seahorses have control over strike distance. In addition, we could not identify the source of the kinematic variability in the activation patterns of the associated muscles. Finally, the stimulation experiment supported the previously hypothesized role of the m. adductor arcus palatini as the trigger in this elastic recoil system. Our results show that pre-stressing of both the head elevators and the hyoid retractors is taking place. As pre-activation of the main muscles involved in pivot feeding has now been demonstrated for both seahorses and pipefish, this is probably a generalized trait of Syngnathidae. PMID:25271759
ERIC Educational Resources Information Center
Lang, Leah; Pirani, Judith A.
2014-01-01
This spotlight focuses on data from the 2013 CDS to better understand how higher education institutions approach financial management systems. Information provided for this spotlight was derived from Module 8 of Core Data Service (CDS), which asked several questions regarding information systems and applications. Responses from 525 institutions…
Canary, Heather E.
2011-01-01
Communication plays an important role in all aspects of the development and use of policy. We present a communication-centered perspective on the processes of enacting public health policies. Our proposed conceptual framework comprises 4 communication frames: orientation, amplification, implementation, and integration. Empirical examples from 2 longitudinal studies of school-based health policies show how each frame includes different communication processes that enable sustainable public health policy practices in school-based health initiatives. These 4 frames provide unique insight into the capacity of school-based public health policy to engage youths, parents, and a broader community of stakeholders. Communication is often included as an element of health policy; however, our framework demonstrates the importance of communication as a pivotal resource in sustaining changes in public health practices. PMID:21233442
Norbert, M.A.; Yale, O.
1992-04-28
A large effective-aperture, low-cost optical telescope with diffraction-limited resolution enables ground-based observation of near-earth space objects. The telescope has a non-redundant, thinned-aperture array in a center-mount, single-structure space frame. It employes speckle interferometric imaging to achieve diffraction-limited resolution. The signal-to-noise ratio problem is mitigated by moving the wavelength of operation to the near-IR, and the image is sensed by a Silicon CCD. The steerable, single-structure array presents a constant pupil. The center-mount, radar-like mount enables low-earth orbit space objects to be tracked as well as increases stiffness of the space frame. In the preferred embodiment, the array has elemental telescopes with subaperture of 2.1 m in a circle-of-nine configuration. The telescope array has an effective aperture of 12 m which provides a diffraction-limited resolution of 0.02 arc seconds. Pathlength matching of the telescope array is maintained by a electro-optical system employing laser metrology. Speckle imaging relaxes pathlength matching tolerance by one order of magnitude as compared to phased arrays. Many features of the telescope contribute to substantial reduction in costs. These include eliminating the conventional protective dome and reducing on-site construction activities. The cost of the telescope scales with the first power of the aperture rather than its third power as in conventional telescopes. 15 figs.
Norbert, Massie A.; Yale, Oster
1992-01-01
A large effective-aperture, low-cost optical telescope with diffraction-limited resolution enables ground-based observation of near-earth space objects. The telescope has a non-redundant, thinned-aperture array in a center-mount, single-structure space frame. It employes speckle interferometric imaging to achieve diffraction-limited resolution. The signal-to-noise ratio problem is mitigated by moving the wavelength of operation to the near-IR, and the image is sensed by a Silicon CCD. The steerable, single-structure array presents a constant pupil. The center-mount, radar-like mount enables low-earth orbit space objects to be tracked as well as increases stiffness of the space frame. In the preferred embodiment, the array has elemental telescopes with subaperture of 2.1 m in a circle-of-nine configuration. The telescope array has an effective aperture of 12 m which provides a diffraction-limited resolution of 0.02 arc seconds. Pathlength matching of the telescope array is maintained by a electro-optical system employing laser metrology. Speckle imaging relaxes pathlength matching tolerance by one order of magnitude as compared to phased arrays. Many features of the telescope contribute to substantial reduction in costs. These include eliminating the conventional protective dome and reducing on-site construction activities. The cost of the telescope scales with the first power of the aperture rather than its third power as in conventional telescopes.
Hospitalists: a chief nursing officer's perspective.
Olender, Lynda
2005-11-01
The hospitalist "specialty" is sweeping the inpatient setting with numbers of physicians choosing this specialty expected to exceed 20,000 by 2010. Yet, little is known about the involvement of nursing in the design, implementation, and evaluation of a hospitalist initiative. The author suggests the chief nursing officer's pivotal role in proactively encouraging the design and implementation of a hospitalist-nurse manager patient-centered care delivery model. The chief nursing officer can create an environment to foster research designed to identify outcomes from this partnership of hospitalist and clinical (nurse) manager.
Earth observations during Space Shuttle flight STS-29 - Discovery's voyage to the earth
NASA Technical Reports Server (NTRS)
Lulla, Kamlesh; Helfert, Michael; Whitehead, Victor; Amsbury, David; Coats, Michael; Blaha, John; Buchli, James; Springer, Robert; Bagian, James
1989-01-01
The environmental, geologic, meteorologic, and oceanographic phenomena documented by earth photography during the Space Shuttle STS-29 mission are reviewed. A map of the nadir point positions of earth-viewing photographs from the mission is given and color photographs of various regions are presented. The mission photographs include atmospheric dust and smoke over parts of Africa and Asia, Sahelian water sites, center pivot irrigation fields in the Middle East, urban smog over Mexico City, isolated burning in the Bolivian Amazon, and various ocean features and cloud formations.
Micromechanisms with floating pivot
Garcia, Ernest J.
2001-03-06
A new class of tilting micromechanical mechanisms have been developed. These new mechanisms use floating pivot structures to relieve some of the problems encountered in the use of solid flexible pivots.
Diamond-anvil high-pressure cell with improved x-ray collimation system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiferl, D.; Olinger, B.W.; Livingston, R.W.
1986-07-22
This patent describes a diamond-anvil high-pressure cell having a tubular piston and a cylinder in which the piston is slidable to effect compression of a pair of opposed diamonds located between the piston and the cylinder. The piston includes a central bore opening on one end, an adjustable X-ray collimation system comprising a tubular insert engageable in the bore of the piston, the insert including a central bore and having first and second ends, with the first end of the insert being closest to the opposed diamonds and the second end of the insert extending out of the open endmore » of the piston, a collimator insertable in the bore of the tubular insert. The collimator has a central bore and having first and second ends corresponding respectively with the first and second ends of the insert, elastomeric pivot means mounted in the bore of the insert at the first end of the insert for flexibly retaining the first end of the collimator while allowing the collimator to pivot within the pivot means, and adjustable locking means located at the second end of the insert for adjusting and securing the second end of the collimator so as to be in alignment with the opposed diamonds.« less
WASP (Write a Scientific Paper) using Excel - 2: Pivot tables.
Grech, Victor
2018-02-01
Data analysis at the descriptive stage and the eventual presentation of results requires the tabulation and summarisation of data. This exercise should always precede inferential statistics. Pivot tables and pivot charts are one of Excel's most powerful and underutilised features, with tabulation functions that immensely facilitate descriptive statistics. Pivot tables permit users to dynamically summarise and cross-tabulate data, create tables in several dimensions, offer a range of summary statistics and can be modified interactively with instant outputs. Large and detailed datasets are thereby easily manipulated making pivot tables arguably the best way to explore, summarise and present data from many different angles. This second paper in the WASP series in Early Human Development provides pointers for pivot table manipulation in Excel™. Copyright © 2018 Elsevier B.V. All rights reserved.
Viangteeravat, Teeradache; Anyanwu, Matthew N; Ra Nagisetty, Venkateswara; Kuscu, Emin
2011-07-15
Massive datasets comprising high-resolution images, generated in neuro-imaging studies and in clinical imaging research, are increasingly challenging our ability to analyze, share, and filter such images in clinical and basic translational research. Pivot collection exploratory analysis provides each user the ability to fully interact with the massive amounts of visual data to fully facilitate sufficient sorting, flexibility and speed to fluidly access, explore or analyze the massive image data sets of high-resolution images and their associated meta information, such as neuro-imaging databases from the Allen Brain Atlas. It is used in clustering, filtering, data sharing and classifying of the visual data into various deep zoom levels and meta information categories to detect the underlying hidden pattern within the data set that has been used. We deployed prototype Pivot collections using the Linux CentOS running on the Apache web server. We also tested the prototype Pivot collections on other operating systems like Windows (the most common variants) and UNIX, etc. It is demonstrated that the approach yields very good results when compared with other approaches used by some researchers for generation, creation, and clustering of massive image collections such as the coronal and horizontal sections of the mouse brain from the Allen Brain Atlas. Pivot visual analytics was used to analyze a prototype of dataset Dab2 co-expressed genes from the Allen Brain Atlas. The metadata along with high-resolution images were automatically extracted using the Allen Brain Atlas API. It is then used to identify the hidden information based on the various categories and conditions applied by using options generated from automated collection. A metadata category like chromosome, as well as data for individual cases like sex, age, and plan attributes of a particular gene, is used to filter, sort and to determine if there exist other genes with a similar characteristics to Dab2. And online access to the mouse brain pivot collection can be viewed using the link http://edtech-dev.uthsc.edu/CTSI/teeDev1/unittest/PaPa/collection.html (user name: tviangte and password: demome) Our proposed algorithm has automated the creation of large image Pivot collections; this will enable investigators of clinical research projects to easily and quickly analyse the image collections through a perspective that is useful for making critical decisions about the image patterns discovered.
Developing a clinical information system: the role of the chief information officer.
Glaser, J
1994-11-01
Chief information officers (CIOs) must play a pivotal role in the formation and implementation of a clinical information system, the subset of an organizational information system that deals specifically with support of clinical care activities. Major elements include the applications software, technology and data architecture, databases, and analysis. The organizational structures and processes that manage the development of improvement activities, including the clinical information system itself, are just as vital to the design of an information system as the hardware and software. To develop, sustain, and advance an information infrastructure, the CIO must help establish certain organizational precursors, such as medical staff involvement, experience with quality improvement, and ability to meet data needs. The CIO must then work with the senior administrative and medical leadership in developing a vision for the information system. The CIO must also create new roles and knowledge for information system and medical staff members. Interaction between information services and medical staff is vitally important to the success of a clinical information system. Organizational committees and structures that Brigham and Women's Hospital in Boston put in place to formalize the relationship between information systems and medical staff include the Clinical Initiative Development Program and the Center for Applied Medical Information Systems Research. Improving the clinical management of care and the efficacy of care processes involves complex changes in organizational culture and processes, medical practice and information system applications, technologies, staff, and data.
State and regional tools for coordinating housing and transportation.
DOT National Transportation Integrated Search
2014-01-01
Federal, state, and local governments spend billions on transportation infrastructure and affordable : housing subsidies, but rarely with complete coordination. States and regional entities are pivotal in : shaping transportation and housing systems....
Competition Among Near-Substitutable Systems
2012-09-01
the context of the dominant “Weapon System Franchise ” model of competition for major defense acquisition programs (MDAPs). Competition between near...leading to the award of a franchise . AoAs or other cost-effectiveness analyses can be pivotal in bringing attention to near-substitute systems. However...dominant ?Weapon System Franchise ? model of competition for major defense acquisition programs (MDAPs). Competition between near-substitutes can occur
Standardized pivot shift test improves measurement accuracy.
Hoshino, Yuichi; Araujo, Paulo; Ahlden, Mattias; Moore, Charity G; Kuroda, Ryosuke; Zaffagnini, Stefano; Karlsson, Jon; Fu, Freddie H; Musahl, Volker
2012-04-01
The variability of the pivot shift test techniques greatly interferes with achieving a quantitative and generally comparable measurement. The purpose of this study was to compare the variation of the quantitative pivot shift measurements with different surgeons' preferred techniques to a standardized technique. The hypothesis was that standardizing the pivot shift test would improve consistency in the quantitative evaluation when compared with surgeon-specific techniques. A whole lower body cadaveric specimen was prepared to have a low-grade pivot shift on one side and high-grade pivot shift on the other side. Twelve expert surgeons performed the pivot shift test using (1) their preferred technique and (2) a standardized technique. Electromagnetic tracking was utilized to measure anterior tibial translation and acceleration of the reduction during the pivot shift test. The variation of the measurement was compared between the surgeons' preferred technique and the standardized technique. The anterior tibial translation during pivot shift test was similar between using surgeons' preferred technique (left 24.0 ± 4.3 mm; right 15.5 ± 3.8 mm) and using standardized technique (left 25.1 ± 3.2 mm; right 15.6 ± 4.0 mm; n.s.). However, the variation in acceleration was significantly smaller with the standardized technique (left 3.0 ± 1.3 mm/s(2); right 2.5 ± 0.7 mm/s(2)) compared with the surgeons' preferred technique (left 4.3 ± 3.3 mm/s(2); right 3.4 ± 2.3 mm/s(2); both P < 0.01). Standardizing the pivot shift test maneuver provides a more consistent quantitative evaluation and may be helpful in designing future multicenter clinical outcome trials. Diagnostic study, Level I.
Yoo, Byung-Kuk; Su, Zixue; Thomas, John Meurig; Zewail, Ahmed H.
2016-01-01
Understanding the dynamical nature of the catalytic active site embedded in complex systems at the atomic level is critical to developing efficient photocatalytic materials. Here, we report, using 4D ultrafast electron microscopy, the spatiotemporal behaviors of titanium and oxygen in a titanosilicate catalytic material. The observed changes in Bragg diffraction intensity with time at the specific lattice planes, and with a tilted geometry, provide the relaxation pathway: the Ti4+=O2− double bond transformation to a Ti3+−O1− single bond via the individual atomic displacements of the titanium and the apical oxygen. The dilation of the double bond is up to 0.8 Å and occurs on the femtosecond time scale. These findings suggest the direct catalytic involvement of the Ti3+−O1− local structure, the significance of nonthermal processes at the reactive site, and the efficient photo-induced electron transfer that plays a pivotal role in many photocatalytic reactions. PMID:26729878
Test stand for precise measurement of impulse and thrust vector of small attitude control jets
NASA Technical Reports Server (NTRS)
Woodruff, J. R.; Chisel, D. M.
1973-01-01
A test stand which accurately measures the impulse bit and thrust vector of reaction jet thrusters used in the attitude control system of space vehicles has been developed. It can be used to measure, in a vacuum or ambient environment, both impulse and thrust vector of reaction jet thrusters using hydrazine or inert gas propellants. The ballistic pendulum configuration was selected because of its accuracy, simplicity, and versatility. The pendulum is mounted on flexure pivots rotating about a vertical axis at the center of its mass. The test stand has the following measurement capabilities: impulse of 0.00004 to 4.4 N-sec (0.00001 to 1.0 lb-sec) with a pulse duration of 0.5 msec to 1 sec; static thrust of 0.22 to 22 N (0.05 to 5 lb) with a 5 percent resolution; and thrust angle alinement of 0.22 to 22 N (0.05 to 5 lb) thrusters with 0.01 deg accuracy.
Evaluating a Pivot-Based Approach for Bilingual Lexicon Extraction
Kim, Jae-Hoon; Kwon, Hong-Seok; Seo, Hyeong-Won
2015-01-01
A pivot-based approach for bilingual lexicon extraction is based on the similarity of context vectors represented by words in a pivot language like English. In this paper, in order to show validity and usability of the pivot-based approach, we evaluate the approach in company with two different methods for estimating context vectors: one estimates them from two parallel corpora based on word association between source words (resp., target words) and pivot words and the other estimates them from two parallel corpora based on word alignment tools for statistical machine translation. Empirical results on two language pairs (e.g., Korean-Spanish and Korean-French) have shown that the pivot-based approach is very promising for resource-poor languages and this approach observes its validity and usability. Furthermore, for words with low frequency, our method is also well performed. PMID:25983745
The Role of the School Principal in Comparative Perspectives.
ERIC Educational Resources Information Center
Geering, Adrian D.
Decentralized school systems make the principal's role more complex in the U.S. than in Australia's highly centralized system. Principals are pivotal to school success in both countries. A principal sets a school's climate, affecting decision-making, communications, educational innovations, and teacher morale, while performing formal tasks…
Development of a Diagnostic and Remedial Learning System Based on an Enhanced Concept--Effect Model
ERIC Educational Resources Information Center
Panjaburees, Patcharin; Triampo, Wannapong; Hwang, Gwo-Jen; Chuedoung, Meechoke; Triampo, Darapond
2013-01-01
With the rapid advances in computer technology during recent years, researchers have demonstrated the pivotal influences of computer-assisted diagnostic systems on student learning performance improvement. This research aims to develop a Diagnostic and Remedial Learning System (DRLS) for an algebra course in a Thai lower secondary school context…
Asmanes, Charles
1979-01-01
A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.
Effect of torsional stiffness and inertia on the dynamics of low aspect ratio flapping wings.
Xiao, Qing; Hu, Jianxin; Liu, Hao
2014-03-01
Micro air vehicle-motivated aerodynamics in biological flight has been an important subject in the past decade. Inspired by the novel flapping wing mechanisms in insects, birds and bats, we have carried out a numerical study systematically investigating a three-dimensional flapping rigid wing with passively actuated lateral and rotational motion. Distinguishing it from the limited existing studies, this work performs a systematic examination on the effects of wing aspect ratio (AR = 1.0 to infinity), inertia (density ratio σ = 4-32), torsional stiffness (frequency ratio F = 1.5-10 and infinity) and pivot point (from chord-center to leading edge) on the dynamics response of a low AR rectangular wing under an initial zero speed flow field condition. The simulation results show that the symmetry breakdown of the flapping wing results in a forward/backward motion with a rotational pitching. When the wing reaches its stable periodic state, the induced pitching frequency is identical to its forced flapping frequency. However, depending on various kinematic and dynamic system parameters, (i.e. flapping frequency, density ratio and pitching axis), the lateral induced velocity shows a number of different oscillating frequencies. Furthermore, compared with a one degree of freedom (DoF) wing in the lateral direction only, the propulsion performance of such a two DoF wing relies very much on the magnitude of torsional stiffness adding on the pivot point, as well as its pitching axis. In all cases examined here, thrust force and moment generated by a long span wing is larger than that of a short wing, which is remarkably linked to the strong reverse von Kármán vortex street formed in the wake of a wing.
Dujovny, M; Kossovsky, N; Kossowsky, R; Valdivia, R; Suk, J S; Diaz, F G; Berman, S K; Cleary, W
1985-10-01
Because of various mechanical, metallurgical, and commercial constraints, aneurysm clips are manufactured from different alloys, including several stainless steel and cobalt alloys. Some of the steels contain volume fractions of the crystal phase known as martensite. Martensitic alloys have body-centered cubic structure, are prone to stress corrosion failure, and are ferromagnetic. Martensitic steel can be displaced like a compass needle when exposed to a magnetic field such as that generated during magnetic resonance imaging (MRI). The force exerted by the magnetic field is proportional to the volume fraction of the magnetic phase. We investigated the martensitic content and magnetic field-induced displacement of 12 common aneurysm clips. Four clips of each of the following types were examined: Sugita, Sundt-Kees Multi-Angle, Heifetz (two types), Vari-Angle McFadden, Yasargil (two types), Scoville, Mayfield, Vari-Angle, Pivot, and Kapp. Phase homogeneity and crystal structure were analyzed by x-ray diffraction using a Phillips x-ray diffractometer. Clip deflection in an Oxford Research Systems MRI spectrometer was measured in our in vivo rat abdominal aortic aneurysm model. Results showed that the volume fraction of the martensitic phase in the various clips correlated with the magnitude of the deflection. Among the clips examined, the Yasargil, Sugita, Heifetz Elgiloy, and Vari-Angle McFadden had a nonmartensitic composition and did not deflect in the magnetic field. The Scoville contained 5% martensite and deflected only marginally. Martensite comprised 35% of the Mayfield clip, which deflected 45 degrees, and 90% of the Heifetz, Vari-Angle, Pivot, and Sundt-Kees Multi-Angle clips, which deflected approximately 70 degrees or slipped off the aneurysm.(ABSTRACT TRUNCATED AT 250 WORDS)
Why Should We Pivot in Gaussian Elimination?
ERIC Educational Resources Information Center
Rozema, Edward
1988-01-01
The article discusses the use of computers to teacher college level mathematics. In particular, the Gaussian elimination procedure for solving a system of n linear equations in n unknowns, using a computer, is examined. (PK)
2013-01-01
Background With the increasing prevalence of Picture Archiving and Communication Systems (PACS) in healthcare institutions, there is a growing need to measure their success. However, there is a lack of published literature emphasizing the technical and social factors underlying a successful PACS. Methods An updated Information Systems Success Model was utilized by radiology technologists (RTs) to evaluate the success of PACS at a large medical center in Taiwan. A survey, consisting of 109 questionnaires, was analyzed by Structural Equation Modeling. Results Socio-technical factors (including system quality, information quality, service quality, perceived usefulness, user satisfaction, and PACS dependence) were proven to be effective measures of PACS success. Although the relationship between service quality and perceived usefulness was not significant, other proposed relationships amongst the six measurement parameters of success were all confirmed. Conclusions Managers have an obligation to improve the attributes of PACS. At the onset of its deployment, RTs will have formed their own subjective opinions with regards to its quality (system quality, information quality, and service quality). As these personal concepts are either refuted or reinforced based on personal experiences, RTs will become either satisfied or dissatisfied with PACS, based on their perception of its usefulness or lack of usefulness. A satisfied RT may play a pivotal role in the implementation of PACS in the future. PMID:24053458
Wallach, Joshua D; Ciani, Oriana; Pease, Alison M; Gonsalves, Gregg S; Krumholz, Harlan M; Taylor, Rod S; Ross, Joseph S
2018-03-21
The U.S. Food and Drug Administration (FDA) often approves new drugs based on trials that use surrogate markers for endpoints, which involve certain trade-offs and may risk making erroneous inferences about the medical product's actual clinical effect. This study aims to compare the treatment effects among pivotal trials supporting FDA approval of novel therapeutics based on surrogate markers of disease with those observed among postapproval trials for the same indication. We searched Drugs@FDA and PubMed to identify published randomized superiority design pivotal trials for all novel drugs initially approved by the FDA between 2005 and 2012 based on surrogate markers as primary endpoints and published postapproval trials using the same surrogate markers or patient-relevant outcomes as endpoints. Summary ratio of odds ratios (RORs) and difference between standardized mean differences (dSMDs) were used to quantify the average difference in treatment effects between pivotal and matched postapproval trials. Between 2005 and 2012, the FDA approved 88 novel drugs for 90 indications based on one or multiple pivotal trials using surrogate markers of disease. Of these, 27 novel drugs for 27 indications were approved based on pivotal trials using surrogate markers as primary endpoints that could be matched to at least one postapproval trial, for a total of 43 matches. For nine (75.0%) of the 12 matches using the same non-continuous surrogate markers as trial endpoints, pivotal trials had larger treatment effects than postapproval trials. On average, treatment effects were 50% higher (more beneficial) in the pivotal than the postapproval trials (ROR 1.5; 95% confidence interval CI 1.01-2.23). For 17 (54.8%) of the 31 matches using the same continuous surrogate markers as trial endpoints, pivotal trials had larger treatment effects than the postapproval trials. On average, there was no difference in treatment effects between pivotal and postapproval trials (dSMDs 0.01; 95% CI -0.15-0.16). Many postapproval drug trials are not directly comparable to previously published pivotal trials, particularly with respect to endpoint selection. Although treatment effects from pivotal trials supporting FDA approval of novel therapeutics based on non-continuous surrogate markers of disease are often larger than those observed among postapproval trials using surrogate markers as trial endpoints, there is no evidence of difference between pivotal and postapproval trials using continuous surrogate markers.
The influence of applied internal and external rotation on the pivot shift phenomenon.
Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland
2017-04-01
The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).
Failure Analysis on Tail Rotor Teeter Pivot Bolt on a Helicopter
NASA Astrophysics Data System (ADS)
Qiang, WANG; Zi-long, DONG
2018-03-01
Tail rotor teeter pivot bolt of a helicopter fractured when in one flight. Failure analysis on the bolt was finished in laboratory. Macroscopic observation of the tailor rotor teeter pivot bolt, macro and microscopic inspection on the fracture surface of the bolt was carried out. Chemical components and metallurgical structure was also carried out. Experiment results showed that fracture mode of the tail rotor teeter pivot bolt is fatigue fracture. Fatigue area is over 80% of the total fracture surface, obvious fatigue band characteristics can be found at the fracture face. According to the results were analyzed from the macroscopic and microcosmic aspects, fracture reasons of the tail rotor teeter pivot bolt were analyzed in detail
Targeting complement-mediated immunoregulation for cancer immunotherapy.
Kolev, Martin; Markiewski, Maciej M
2018-06-01
Complement was initially discovered as an assembly of plasma proteins "complementing" the cytolytic activity of antibodies. However, our current knowledge places this complex system of several plasma proteins, receptors, and regulators in the center of innate immunity as a bridge between the initial innate responses and adaptive immune reactions. Consequently, complement appears to be pivotal for elimination of pathogens, not only as an early response defense, but by directing the subsequent adaptive immune response. The discovery of functional intracellular complement and its roles in cellular metabolism opened novel avenues for research and potential therapeutic implications. The recent studies demonstrating immunoregulatory functions of complement in the tumor microenvironment and the premetastatic niche shifted the paradigm on our understanding of functions of the complement system in regulating immunity. Several complement proteins, through their interaction with cells in the tumor microenvironment and in metastasis-targeted organs, contribute to modulating tumor growth, antitumor immunity, angiogenesis, and therefore, the overall progression of malignancy and, perhaps, responsiveness of cancer to different therapies. Here, we focus on recent progress in our understanding of immunostimulatory vs. immunoregulatory functions of complement and potential applications of these findings to the design of novel therapies for cancer patients. Copyright © 2018 Elsevier Ltd. All rights reserved.
Bock, Eduardo; Antunes, Pedro; Leao, Tarcisio; Uebelhart, Beatriz; Fonseca, Jeison; Leme, Juliana; Utiyama, Bruno; da Silva, Cibele; Cavalheiro, Andre; Filho, Diolino Santos; Dinkhuysen, Jarbas; Biscegli, Jose; Andrade, Aron; Arruda, Celso
2011-05-01
An implantable centrifugal blood pump has been developed with original features for a left ventricular assist device. This pump is part of a multicenter and international study with the objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations and wear evaluation in bearing system were performed followed by prototyping and in vitro tests. In addition, previous blood tests for assessment of normalized index of hemolysis show results of 0.0054±2.46 × 10⁻³ mg/100 L. An electromechanical actuator was tested in order to define the best motor topology and controller configuration. Three different topologies of brushless direct current motor (BLDCM) were analyzed. An electronic driver was tested in different situations, and the BLDCM had its mechanical properties tested in a dynamometer. Prior to evaluation of performance during in vivo animal studies, anatomical studies were necessary to achieve the best configuration and cannulation for left ventricular assistance. The results were considered satisfactory, and the next step is to test the performance of the device in vivo. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Aeroelastic character of a National Aerospace Plane demonstrator concept
NASA Technical Reports Server (NTRS)
Spain, Charles V.; Zeiler, Thomas A.; Gibbons, Michael D.; Soistmann, David L.; Pozefsky, Peter; Dejesus, Rafael O.; Brannon, Cyprian P.
1993-01-01
The paper provides an analytical assessment of the flutter character of an unclassified National Aerospace Plane configuration known as the demonstrator. Linear subsonic, supersonic, and hypersonic analysis indicate that the vehicle is prone to body-freedom flutter resulting from the decrease in vibration frequency of the all-moveable wing at high flight dynamic pressures. As the wing-pivot frequency decreases, it couples with the vehicle short-period mode resulting in dynamic instability. A similar instability sometimes occurs when the pivot mode couples with the fuselage-bending mode. Also assessed, for supersonic flight conditions, are configuration variations that include relocation of the wing further aft on the lifting-body fuselage, and the addition of body flaps to the rear of the vehicle. These changes are destabilizing because they result in severe wing-pivot/fuselage-bending instabilities at dynamic pressures lower than the instabilities indicated for the original demonstrator. Finally, a two-point wing support and actuation system concept is proposed for the National Aerospace Plane, which if developed may (according to cursory analysis) enhance overall stability.
TXDOT ITS strategic plan 2013.
DOT National Transportation Integrated Search
2014-04-01
TxDOTs mission is to provide safe and reliable transportation solutions for the citizens of Texas. Intelligent transportation systems (ITS) can play a pivotal role in meeting that mission. TxDOT can take advantage of advanced and emerging technolo...
Visualization in mechanics: the dynamics of an unbalanced roller
NASA Astrophysics Data System (ADS)
Cumber, Peter S.
2017-04-01
It is well known that mechanical engineering students often find mechanics a difficult area to grasp. This article describes a system of equations describing the motion of a balanced and an unbalanced roller constrained by a pivot arm. A wide range of dynamics can be simulated with the model. The equations of motion are embedded in a graphical user interface for its numerical solution in MATLAB. This allows a student's focus to be on the influence of different parameters on the system dynamics. The simulation tool can be used as a dynamics demonstrator in a lecture or as an educational tool driven by the imagination of the student. By way of demonstration the simulation tool has been applied to a range of roller-pivot arm configurations. In addition, approximations to the equations of motion are explored and a second-order model is shown to be accurate for a limited range of parameters.
Virtual Tutoring and Student Support Systems
ERIC Educational Resources Information Center
Geary, Jennifer Lee
2005-01-01
Virtual tutoring and student support systems may be pivotal in developing opportunities of equality and of outcome for students who study at a distance. Cookson (2002) mentions that it is important to assist students to have access to study programs. Cookson (2002) elaborates upon this and states, "If access is to be equitable, once they are…
Quality, Social Justice and Accountability--Crucial Determinants of Excellence in Education
ERIC Educational Resources Information Center
Rossouw, J. P.
2015-01-01
Internationally, the quality of education, social justice and accountability can be regarded as key elements of successful school systems and societies. Separately or jointly, these elements can be analysed and debated as distinct fields of study, and linked to an education system to determine the success thereof. Being a pivotal element of…
Co-Expression analysis of miRNAs and target NBS-LRR genes in Cucumis sativus
USDA-ARS?s Scientific Manuscript database
Plants react against their biological enemies by activating the innate immune system. Their defense system comprises of various R-protein, which usually contain NBS-LRR domain. MicroRNAs (miRNAs) are important molecules of 2nd layer of plant defense and play pivotal role behind the scene. To support...
State Guide to Developing Successful Early Childhood Data Systems
ERIC Educational Resources Information Center
ICF International (NJ1), 2012
2012-01-01
Early education leaders--inside and outside of government--are looking for new ways to improve quality, accountability, and efficiency across many different programs serving young children and their families, and they see investment in data systems as a pivotal part of that effort. However, it can be challenging to develop and implement effective…
Understanding Usefulness in Human-Computer Interaction to Enhance User Experience Evaluation
ERIC Educational Resources Information Center
MacDonald, Craig Matthew
2012-01-01
The concept of usefulness has implicitly played a pivotal role in evaluation research, but the meaning of usefulness has changed over time from system reliability to user performance and learnability/ease of use for non-experts. Despite massive technical and social changes, usability remains the "gold standard" for system evaluation.…
49 CFR 571.213 - Standard No. 213; Child restraint systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the initial pre-test position of the respective knee pivot point, measured along a horizontal line... test dummy, specified in S7, when a child restraint system is tested in accordance with S6.1. Factory... body of a seated anthropomorphic test dummy, excluding the thighs, that lies between the top of the...
49 CFR 571.213 - Standard No. 213; Child restraint systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the initial pre-test position of the respective knee pivot point, measured along a horizontal line... test dummy, specified in S7, when a child restraint system is tested in accordance with S6.1. Factory... body of a seated anthropomorphic test dummy, excluding the thighs, that lies between the top of the...
49 CFR 571.213 - Standard No. 213; Child restraint systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the initial pre-test position of the respective knee pivot point, measured along a horizontal line... the head or torso of the appropriate test dummy, specified in S7, when a child restraint system is... (§ 571.225). Torso means the portion of the body of a seated anthropomorphic test dummy, excluding the...
Base excitation testing system using spring elements to pivotally mount wind turbine blades
Cotrell, Jason; Hughes, Scott; Butterfield, Sandy; Lambert, Scott
2013-12-10
A system (1100) for fatigue testing wind turbine blades (1102) through forced or resonant excitation of the base (1104) of a blade (1102). The system (1100) includes a test stand (1112) and a restoring spring assembly (1120) mounted on the test stand (1112). The restoring spring assembly (1120) includes a primary spring element (1124) that extends outward from the test stand (1112) to a blade mounting plate (1130) configured to receive a base (1104) of blade (1102). During fatigue testing, a supported base (1104) of a blad (1102) may be pivotally mounted to the test stand (1112) via the restoring spring assembly (1120). The system (1100) may include an excitation input assembly (1140) that is interconnected with the blade mouting plate (1130) to selectively apply flapwise, edgewise, and/or pitch excitation forces. The restoring spring assemply (1120) may include at least one tuning spring member (1127) positioned adjacent to the primary spring element (1124) used to tune the spring constant or stiffness of the primary spring element (1124) in one of the excitation directions.
2007-01-30
KENNEDY SPACE CENTER, FLA. -- The rotating service structure on Launch Pad 39A is being moved for the first time in more than a year due to maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15. Photo credit: NASA/George Shelton
2007-01-30
KENNEDY SPACE CENTER, FLA. -- The rotating service structure on Launch Pad 39A has been fully opened for the first time in more than a year due to maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15. Photo credit: NASA/George Shelton
2007-01-30
KENNEDY SPACE CENTER, FLA. -- The rotating service structure on Launch Pad 39A has moved for the first time in more than a year due to maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15. Photo credit: NASA/George Shelton
2007-01-30
KENNEDY SPACE CENTER, FLA. -- The rotating service structure on Launch Pad 39A is being moved for the first time in more than a year due to maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15. Photo credit: NASA/George Shelton
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2017-10-01
The purpose of this study was to compare the long-term clinical results, radiographic results, range of knee motion, patient satisfaction, and the survival rate of Medial-Pivot posterior cruciate-substituting, knee prosthesis and a press-fit condylar (PFC) Sigma cruciate-retaining mobile-bearing knee prosthesis in the same patients. One hundred eighty-two patients received Medial-Pivot knee prosthesis in one knee and a PFC Sigma knee prosthesis in the contralateral knee. The minimum duration of follow-up was 11 years (range, 11-12.6 years). The knees with a Medial-Pivot knee prosthesis had significantly worse results than those with a PFC Sigma knee prosthesis at the final follow-up with regard to the mean postoperative Knee Society knee scores (90 compared with 95 points), Western Ontario and McMaster Universities Osteoarthritis Index score (25 compared with 18 points), and range of knee motion (117° compared with 128°). Patients were more satisfied with PFC Sigma knee prosthesis (93%) than with Medial-Pivot knee prosthesis (75%). Complication rates were significantly higher in the Medial-Pivot knee group (26%) than those in the PFC Sigma knee group (6.5%). Radiographic results and survival rates (99% compared with 99.5%) were similar between the 2 groups. Although the long-term fixation and survival rate of both Medial-Pivot and PFC Sigma prostheses were similar, we observed a worse knee score, worse range of knee motion, and patient satisfaction was less in the Medial-Pivot knee group than in the PFC Sigma knee group. Furthermore, complication rate was also higher in the Medial-Pivot knee group than the other group. Copyright © 2017 Elsevier Inc. All rights reserved.
2011-01-01
Background Massive datasets comprising high-resolution images, generated in neuro-imaging studies and in clinical imaging research, are increasingly challenging our ability to analyze, share, and filter such images in clinical and basic translational research. Pivot collection exploratory analysis provides each user the ability to fully interact with the massive amounts of visual data to fully facilitate sufficient sorting, flexibility and speed to fluidly access, explore or analyze the massive image data sets of high-resolution images and their associated meta information, such as neuro-imaging databases from the Allen Brain Atlas. It is used in clustering, filtering, data sharing and classifying of the visual data into various deep zoom levels and meta information categories to detect the underlying hidden pattern within the data set that has been used. Method We deployed prototype Pivot collections using the Linux CentOS running on the Apache web server. We also tested the prototype Pivot collections on other operating systems like Windows (the most common variants) and UNIX, etc. It is demonstrated that the approach yields very good results when compared with other approaches used by some researchers for generation, creation, and clustering of massive image collections such as the coronal and horizontal sections of the mouse brain from the Allen Brain Atlas. Results Pivot visual analytics was used to analyze a prototype of dataset Dab2 co-expressed genes from the Allen Brain Atlas. The metadata along with high-resolution images were automatically extracted using the Allen Brain Atlas API. It is then used to identify the hidden information based on the various categories and conditions applied by using options generated from automated collection. A metadata category like chromosome, as well as data for individual cases like sex, age, and plan attributes of a particular gene, is used to filter, sort and to determine if there exist other genes with a similar characteristics to Dab2. And online access to the mouse brain pivot collection can be viewed using the link http://edtech-dev.uthsc.edu/CTSI/teeDev1/unittest/PaPa/collection.html (user name: tviangte and password: demome) Conclusions Our proposed algorithm has automated the creation of large image Pivot collections; this will enable investigators of clinical research projects to easily and quickly analyse the image collections through a perspective that is useful for making critical decisions about the image patterns discovered. PMID:21884637
Jorde, Ulrich P; Kushwaha, Sudhir S; Tatooles, Antone J; Naka, Yoshifumi; Bhat, Geetha; Long, James W; Horstmanshof, Douglas A; Kormos, Robert L; Teuteberg, Jeffrey J; Slaughter, Mark S; Birks, Emma J; Farrar, David J; Park, Soon J
2014-05-06
A post-approval (PA) study for destination therapy (DT) was required by the Food and Drug Administration (FDA) to determine whether results with the HeartMate (HM) II (Thoratec, Pleasanton, California) left ventricular assist device (LVAD) in a commercial setting were comparable to results during the DT multicenter pivotal clinical trial. New device technology developed in the clinical research setting requires validation in a real-world setting. The PA study was a prospective evaluation of the first 247 HM II patients identified pre-operatively as eligible for DT in the national INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) registry. Patients were enrolled from January to September 2010 at 61 U.S. centers and followed for 2 years. A historical comparison group included patients (n = 133 at 34 centers) enrolled in the primary data cohort in the DT pivotal trial (TR). Survival rates and adverse events for the PA group were obtained from the INTERMACS registry. Baseline characteristics were similar for PA versus TR. Forty-five percent of PA patients were in INTERMACS profiles 1 to 2 and 28% were in profile 3. Adverse events in the PA group were similar or lower than those in the TR group, including improvements in device-related infection (0.22 vs. 0.47) and post-operative bleeding requiring surgery (0.09 vs. 0.23) events per patient-year. Kaplan-Meier survival at 2 years was 62% (PA group) versus 58% (TR group). PA group survival at 1 and 2 years was 82 ± 5% and 69 ± 6% for INTERMACS profiles 4 to 7 (n = 63) versus 72 ± 3% and 60 ± 4% for profiles 1 to 3 (n = 184). The median length of stay after surgery was reduced by 6 days in the PA group versus the TR group. Results in a commercial patient care setting for the DT population supported the original pivotal clinical trial findings regarding the efficacy and risk profile of the HM II LVAD. Survival was best in patients who were not inotrope-dependent (INTERMACS profiles 4 to 7). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Pivotal Response Training. What Works Clearinghouse Intervention Report
ERIC Educational Resources Information Center
What Works Clearinghouse, 2016
2016-01-01
This intervention report presents findings from a systematic review of "pivotal response training" conducted using the What Works Clearinghouse Procedures and Standards Handbook (version 3.0) and the Children and Students with an Autism Spectrum Disorder review protocol (version 3.0). "Pivotal response training"…
Remote controlled vacuum joint closure mechanism
Doll, David W.; Hager, E. Randolph
1986-01-01
A remotely operable and maintainable vacuum joint closure mechanism for a noncircular aperture is disclosed. The closure mechanism includes an extendible bellows coupled at one end to a noncircular duct and at its other end to a flange assembly having sealed grooves for establishing a high vacuum seal with the abutting surface of a facing flange which includes an aperture forming part of the system to be evacuated. A plurality of generally linear arrangements of pivotally coupled linkages and piston combinations are mounted around the outer surface of the duct and aligned along the length thereof. Each of the piston/linkage assemblies is adapted to engage the flange assembly by means of a respective piston and is further coupled to a remote controlled piston drive shaft to permit each of the linkages positioned on a respective flat outer surface of the duct to simultaneously and uniformly displace a corresponding piston and the flange assembly with which it is in contact along the length of the duct in extending the bellows to provide a high vacuum seal between the movable flange and the facing flange. A plurality of latch mechanisms are also pivotally mounted on the outside of the duct. A first end of each of the latch mechanisms is coupled to a remotely controlled latch control shaft for displacing the latch mechanism about its pivot point. In response to the pivoting displacement of the latch mechanism, a second end thereof is displaced so as to securely engage the facing flange.
Xia, Mingrui; Lin, Qixiang; Bi, Yanchao; He, Yong
2016-01-01
White matter (WM) tracts serve as important material substrates for information transfer across brain regions. However, the topological roles of WM tracts in global brain communications and their underlying microstructural basis remain poorly understood. Here, we employed diffusion magnetic resonance imaging and graph-theoretical approaches to identify the pivotal WM connections in human whole-brain networks and further investigated their wiring substrates (including WM microstructural organization and physical consumption) and topological contributions to the brain's network backbone. We found that the pivotal WM connections with highly topological-edge centrality were primarily distributed in several long-range cortico-cortical connections (including the corpus callosum, cingulum and inferior fronto-occipital fasciculus) and some projection tracts linking subcortical regions. These pivotal WM connections exhibited high levels of microstructural organization indicated by diffusion measures (the fractional anisotropy, the mean diffusivity and the axial diffusivity) and greater physical consumption indicated by streamline lengths, and contributed significantly to the brain's hubs and the rich-club structure. Network motif analysis further revealed their heavy participations in the organization of communication blocks, especially in routes involving inter-hemispheric heterotopic and extremely remote intra-hemispheric systems. Computational simulation models indicated the sharp decrease of global network integrity when attacking these highly centralized edges. Together, our results demonstrated high building-cost consumption and substantial communication capacity contributions for pivotal WM connections, which deepens our understanding of the topological mechanisms that govern the organization of human connectomes. PMID:27148015
Xia, Mingrui; Lin, Qixiang; Bi, Yanchao; He, Yong
2016-01-01
White matter (WM) tracts serve as important material substrates for information transfer across brain regions. However, the topological roles of WM tracts in global brain communications and their underlying microstructural basis remain poorly understood. Here, we employed diffusion magnetic resonance imaging and graph-theoretical approaches to identify the pivotal WM connections in human whole-brain networks and further investigated their wiring substrates (including WM microstructural organization and physical consumption) and topological contributions to the brain's network backbone. We found that the pivotal WM connections with highly topological-edge centrality were primarily distributed in several long-range cortico-cortical connections (including the corpus callosum, cingulum and inferior fronto-occipital fasciculus) and some projection tracts linking subcortical regions. These pivotal WM connections exhibited high levels of microstructural organization indicated by diffusion measures (the fractional anisotropy, the mean diffusivity and the axial diffusivity) and greater physical consumption indicated by streamline lengths, and contributed significantly to the brain's hubs and the rich-club structure. Network motif analysis further revealed their heavy participations in the organization of communication blocks, especially in routes involving inter-hemispheric heterotopic and extremely remote intra-hemispheric systems. Computational simulation models indicated the sharp decrease of global network integrity when attacking these highly centralized edges. Together, our results demonstrated high building-cost consumption and substantial communication capacity contributions for pivotal WM connections, which deepens our understanding of the topological mechanisms that govern the organization of human connectomes.
The Efficiency of Small Bearings in Instruments of the Type Used in Aircraft
NASA Technical Reports Server (NTRS)
Norton, F H
1921-01-01
This report deals with the construction and properties of bearings and pivots for use in instruments. The static and running friction for both thrust and radial loads was determined for a number of conical pivots and cylindrical and ball bearings. The static rocking friction was also measured for several conical and ball bearings under a heavy load, especially to determine their suitability for use in N. P. L. (National Physical Laboratory) type wind tunnel balance. In constructing conical pivots and sockets it was found that the pivots should be hardened and highly polished, preferably with a revolving lap, and that the sockets should be made by punching with a hardened and polished punch. It was found that for a light load the conical pivots give less friction than any other type, and their wearing qualities when hardened are excellent. Very small ball bearings are unsatisfactory because the proportional accuracy of the balls and races is not high enough to insure smooth running. For rocking pivots under heavy loads it was found that a ball-and-socket bearing, consisting of a hemispherical socket and a sphere of smaller diameter concentric with it, with a row of small balls resting between the two, was superior to a pivot resting in a socket. It was found that vibration such as occurs in an airplane will greatly reduce the static friction of a pivot or bearing, in some cases to as little as one-twentieth of its static value.
NASA Technical Reports Server (NTRS)
Cody, E. R.; Deats, C. L.; Derocher, W. L., Jr.; Kyrias, G. M.; Snodgrass, M. R.; Sosnay, R. D.; Spencer, R. A.; Wudell, A. E.
1975-01-01
Orbital maintenance concepts were examined in an effort to determine a cost effective orbital maintenance system compatible with the space transportation system. An on-orbit servicer maintenance system is recommended as the most cost effective system. A pivoting arm on-orbit servicer was selected and a preliminary design was prepared. It is indicated that orbital maintenance does not have any significant impact on the space transportation system.
NASA Technical Reports Server (NTRS)
Bradley, Glen L.
1993-01-01
Wrench ends pivot so it can be used to loosen or tighten nuts or bolts in confined spaces. One end equipped with open-end socket; other end, with double-hexagon socket. Heads pivot on pins. Pins fit tightly so heads do not flop; friction on pins sufficient to hold heads in positions until rotated intentionally.
A sustainable model for training teachers to use pivotal response training.
Suhrheinrich, Jessica
2015-08-01
The increase in the rate of autism diagnoses has created a growing demand for teachers who are trained to use effective interventions. The train-the-trainer model, which involves training supervisors to train others, may be ideal for providing cost-effective training and ongoing support to teachers. Although research supports interventions, such as pivotal response training, as evidence-based, dissemination to school environments has been problematic. This study assessed the benefits of using the train-the-trainer model to disseminate pivotal response training to school settings. A multiple-baseline design was conducted across three training groups, each consisting of one school staff member (trainer), three special education teachers, and six students. Trainers conducted the teacher-training workshop with high adherence to training protocol and met mastery criteria in their ability to implement pivotal response training, assess implementation of pivotal response training, and provide feedback to teachers. Six of the nine teachers mastered all components of pivotal response training. The remaining three teachers implemented 89% of the pivotal response training components correctly. The majority of trainers and teachers maintained their abilities at follow-up. These results support the use of the train-the-trainer model as an effective method of disseminating evidence-based practices in school settings. © The Author(s) 2014.
A single dual-stream framework for syntactic computations in music and language.
Musso, Mariacristina; Weiller, Cornelius; Horn, Andreas; Glauche, Volkmer; Umarova, Roza; Hennig, Jürgen; Schneider, Albrecht; Rijntjes, Michel
2015-08-15
This study is the first to compare in the same subjects the specific spatial distribution and the functional and anatomical connectivity of the neuronal resources that activate and integrate syntactic representations during music and language processing. Combining functional magnetic resonance imaging with functional connectivity and diffusion tensor imaging-based probabilistic tractography, we examined the brain network involved in the recognition and integration of words and chords that were not hierarchically related to the preceding syntax; that is, those deviating from the universal principles of grammar and tonal relatedness. This kind of syntactic processing in both domains was found to rely on a shared network in the left hemisphere centered on the inferior part of the inferior frontal gyrus (IFG), including pars opercularis and pars triangularis, and on dorsal and ventral long association tracts connecting this brain area with temporo-parietal regions. Language processing utilized some adjacent left hemispheric IFG and middle temporal regions more than music processing, and music processing also involved right hemisphere regions not activated in language processing. Our data indicate that a dual-stream system with dorsal and ventral long association tracts centered on a functionally and structurally highly differentiated left IFG is pivotal for domain-general syntactic competence over a broad range of elements including words and chords. Copyright © 2015 Elsevier Inc. All rights reserved.
The Conduit and Whirlpooling: A New Theory of Knowledge Constitution and Dispersion
ERIC Educational Resources Information Center
Nzegwu, Azuka
2010-01-01
There is a new epistemological approach for exploring knowledge constitution and dispersal in a dynamic Web ecosystem. The approach has three pivots. The first presents virtual whirlpools as knowledge systems. The second introduces the creator of the system as the Conduit. The third formulates a theory of knowledge that involves the collective…
"Catalyst Data": Perverse Systemic Effects of Audit and Accountability in Australian Schooling
ERIC Educational Resources Information Center
Lingard, Bob; Sellar, Sam
2013-01-01
This paper examines the perverse effects of the new accountability regime central to the Labor government's national reform agenda in schooling. The focus is on National Assessment Program -- Literacy and Numeracy (NAPLAN) results that now act as "catalyst data" and are pivotal to school and system accountability. We offer a case study,…
Pivot methods for global optimization
NASA Astrophysics Data System (ADS)
Stanton, Aaron Fletcher
A new algorithm is presented for the location of the global minimum of a multiple minima problem. It begins with a series of randomly placed probes in phase space, and then uses an iterative redistribution of the worst probes into better regions of phase space until a chosen convergence criterion is fulfilled. The method quickly converges, does not require derivatives, and is resistant to becoming trapped in local minima. Comparison of this algorithm with others using a standard test suite demonstrates that the number of function calls has been decreased conservatively by a factor of about three with the same degrees of accuracy. Two major variations of the method are presented, differing primarily in the method of choosing the probes that act as the basis for the new probes. The first variation, termed the lowest energy pivot method, ranks all probes by their energy and keeps the best probes. The probes being discarded select from those being kept as the basis for the new cycle. In the second variation, the nearest neighbor pivot method, all probes are paired with their nearest neighbor. The member of each pair with the higher energy is relocated in the vicinity of its neighbor. Both methods are tested against a standard test suite of functions to determine their relative efficiency, and the nearest neighbor pivot method is found to be the more efficient. A series of Lennard-Jones clusters is optimized with the nearest neighbor method, and a scaling law is found for cpu time versus the number of particles in the system. The two methods are then compared more explicitly, and finally a study in the use of the pivot method for solving the Schroedinger equation is presented. The nearest neighbor method is found to be able to solve the ground state of the quantum harmonic oscillator from a pure random initialization of the wavefunction.
Vessel structural support system
Jenko, James X.; Ott, Howard L.; Wilson, Robert M.; Wepfer, Robert M.
1992-01-01
Vessel structural support system for laterally and vertically supporting a vessel, such as a nuclear steam generator having an exterior bottom surface and a side surface thereon. The system includes a bracket connected to the bottom surface. A support column is pivotally connected to the bracket for vertically supporting the steam generator. The system also includes a base pad assembly connected pivotally to the support column for supporting the support column and the steam generator. The base pad assembly, which is capable of being brought to a level position by turning leveling nuts, is anchored to a floor. The system further includes a male key member attached to the side surface of the steam generator and a female stop member attached to an adjacent wall. The male key member and the female stop member coact to laterally support the steam generator. Moreover, the system includes a snubber assembly connected to the side surface of the steam generator and also attached to the adjacent wall for dampening lateral movement of the steam generator. In addition, the system includes a restraining member of "flat" attached to the side surface of the steam generator and a bumper attached to the adjacent wall. The flat and the bumper coact to further laterally support the steam generator.
Research to develop an ITS strategic plan for Texas.
DOT National Transportation Integrated Search
2014-04-01
TxDOTs mission is to provide safe and reliable transportation solutions for the citizens of Texas. Intelligent : transportation systems (ITS) can play a pivotal role in meeting that mission. TxDOT can take advantage of : advanced and emerging tech...
Drapery assembly including insulated drapery liner
Cukierski, Gwendolyn
1983-01-01
A drapery assembly is disclosed for covering a framed wall opening, the assembly including drapery panels hung on a horizontal traverse rod, the rod having a pair of master slides and means for displacing the master slides between open and closed positions. A pair of insulating liner panels are positioned behind the drapery, the remote side edges of the liner panels being connected with the side portions of the opening frame, and the adjacent side edges of the liner panels being connected with a pair of vertically arranged center support members adapted for sliding movement longitudinally of a horizontal track member secured to the upper horizontal portion of the opening frame. Pivotally arranged brackets connect the center support members with the master slides of the traverse rod whereby movement of the master slides to effect opening and closing of the drapery panels effects simultaneous opening and closing of the liner panels.
Ugolini, D; Bogliolo, A; Parodi, S; Casilli, C; Santi, L
1997-01-01
An evaluation method used to assess the quality of research productivity and to provide priorities for budget allocation purposes is presented. This method, developed by a working group of the National Institute for Research on Cancer (IST), Genoa, Italy, is based on the partitioning of categories of the Science Citation Index and Journal Citation Reports (SCI-JCR) into deciles, which normalizes journal impact factors in order to gauge the quality of the productivity. A second parameter related to the number of staff of each institute department co-authoring a given paper has been introduced in order to guide departmental budget allocations. The information scientists of the IST Documentation Center who participated in the working group played a pivotal role in developing the computerized database of publications, providing and analyzing data, supplying and evaluating literature on the topic, and placing international bibliographic databases at the working group's disposal. PMID:9028569
A Multidimensional Data Warehouse for Community Health Centers
Kunjan, Kislaya; Toscos, Tammy; Turkcan, Ayten; Doebbeling, Brad N.
2015-01-01
Community health centers (CHCs) play a pivotal role in healthcare delivery to vulnerable populations, but have not yet benefited from a data warehouse that can support improvements in clinical and financial outcomes across the practice. We have developed a multidimensional clinic data warehouse (CDW) by working with 7 CHCs across the state of Indiana and integrating their operational, financial and electronic patient records to support ongoing delivery of care. We describe in detail the rationale for the project, the data architecture employed, the content of the data warehouse, along with a description of the challenges experienced and strategies used in the development of this repository that may help other researchers, managers and leaders in health informatics. The resulting multidimensional data warehouse is highly practical and is designed to provide a foundation for wide-ranging healthcare data analytics over time and across the community health research enterprise. PMID:26958297
A Multidimensional Data Warehouse for Community Health Centers.
Kunjan, Kislaya; Toscos, Tammy; Turkcan, Ayten; Doebbeling, Brad N
2015-01-01
Community health centers (CHCs) play a pivotal role in healthcare delivery to vulnerable populations, but have not yet benefited from a data warehouse that can support improvements in clinical and financial outcomes across the practice. We have developed a multidimensional clinic data warehouse (CDW) by working with 7 CHCs across the state of Indiana and integrating their operational, financial and electronic patient records to support ongoing delivery of care. We describe in detail the rationale for the project, the data architecture employed, the content of the data warehouse, along with a description of the challenges experienced and strategies used in the development of this repository that may help other researchers, managers and leaders in health informatics. The resulting multidimensional data warehouse is highly practical and is designed to provide a foundation for wide-ranging healthcare data analytics over time and across the community health research enterprise.
Earth observations taken during STS-83 mission
2016-08-12
STS083-747-033 (4-8 April 1997) --- Center Pivot Irrigation, in Saudi Arabia. This irrigation project in Saudi Arabia is typical of many isolated irrigation projects scattered throughout the arid and hyper-arid regions of the Earth. Fossil water is mined from depths as great as 3,000 feet, pumped to the surface, and distributed via large center pivot irrigation feeds. The circles of green irrigated vegetation may comprise a variety of agricultural commodities from alfalfa to wheat. Diameters of the normally circular fields range from a few hundred meters to as much as 2 miles. The projects often trace out a narrow, sinuous, and seemingly random path. Actually, engineers generally seek ancient river channels now buried by the sand seas. The fossil waters mined in these projects accumulated during periods of wetter climate in the Pleistocene glacial epochs, between 10,000 to 2 million years ago, and are not being replenished under current climatic conditions. The projects, therefore, will have limited production as the reservoirs are drained. Water, of course, is the key to agriculture in Saudi Arabia. The Kingdom has implemented a multifaceted program to provide the vast supplies of water necessary to achieve the spectacular growth of the agricultural sector. A network of dams has been built to trap and utilize precious seasonal floods. Vast underground water reservoirs have been tapped through deep wells. Desalination plants have been built to produce fresh water from the sea for urban and industrial use, thereby freeing other sources for agriculture. Facilities have also been put into place to treat urban and industrial run-off for agricultural irrigation. These efforts collectively have helped transform vast tracts of the desert into fertile farmland. Land under cultivation has grown from under 400,000 acres in 1976 to more than 8 million acres in 1993.
Koo, Chi-Kin; Wong, Ka-Leung; Lau, Kai-Cheung; Wong, Wai-Yeung; Lam, Michael Hon-Wah
2009-08-03
The bis(diphenylphosphino)methane (dppm)-bridged dinuclear cycloplatinated complex {[Pt(L)](2)(mu-dppm)}(2+) (Pt(2)dppm; HL: 2-phenyl-6-(1H-pyrazol-3-yl)-pyridine) demonstrates interesting reversible "pivot-hinge"-like intramolecular motions in response to the protonation/deprotonation of L. In its protonated "closed" configuration, the two platinum(II) centers are held in position by intramolecular d(8)-d(8) Pt-Pt interaction. In its deprotonated "open" configuration, such Pt-Pt interaction is cleaved. To further understand the mechanism behind this hingelike motion, an analogous dinuclear cycloplatinated complex, {[Pt(L)](2)(mu-dchpm)}(2+) (Pt(2)dchpm) with bis(dicyclohexylphosphino)methane (dchpm) as the bridging ligand, was synthesized. From its protonation/deprotonation responses, it was revealed that aromatic pi-pi interactions between the phenyl moieties of the mu-dppm and the deprotonated pyrazolyl rings of L was essential to the reversible cleavage of the intramolecular Pt-Pt interaction in Pt(2)dppm. In the case of Pt(2)dchpm, spectroscopic and spectrofluorometric titrations as well as X-ray crystallography indicated that the distance between the two platinum(II) centers shrank upon deprotonation, thus causing a redshift in its room-temperature triplet metal-metal-to-ligand charge-transfer emission from 614 to 625 nm. Ab initio calculations revealed the presence of intramolecular hydrogen bonding between the deprotonated and negatively charged 1-pyrazolyl-N moiety and the methylene CH and phenyl C-H of the mu-dppm. The "open" configuration of the deprotonated Pt(2)dppm was estimated to be 19 kcal mol(-1) more stable than its alternative "closed" configuration. On the other hand, the open configuration of the deprotonated Pt(2)dchpm was 6 kcal mol(-1) less stable than its alternative closed configuration.
Kaur, Paramjeet; Jiang, Xiaojian; Stier, Ethan
2017-01-01
The US FDA's rule on "Requirements for Submission of Bioequivalence Data" requiring submission of all bioequivalence (BE) studies conducted on the same formulation of the drug product submitted for approval was published in Federal Register in January 2009. With the publication of this rule, we evaluated the impact of data from non-pivotal BE studies in assessing BE and identified the reasons for failed in vivo BE studies for generic oral delayed-release (DR) drug products only. We searched the Agency databases from January 2009 toDecember 2016 to identify Abbreviated New Drug Applications (ANDAs) submitted for DR drug products containing non-pivotal BE studies. Out of 202 ANDAs, 43 ANDAs contained 102 non-pivotal BE studies. Forty-nine non-pivotal BE studies were conducted on the to-be-marketed (TBM) formulation and 53 were conducted on formulations different from the TBM formulation. These experimental formulations primarily differed in the ratio of components of the enteric coating layer and/or amount (i.e., %w/w) of enteric coating layer. Of the 49 non-pivotal BE studies conducted on the TBM formulation, 41 failed to meet the BE acceptance criteria. The majority of failed non-pivotal BE studies on the TBM DR generic products had insufficient power, which was expected as these studies are exploratory in nature and not designed to have adequate power to pass the BE statistical criteria. In addition, among the failed non-pivotal BE studies on the TBM DR generic products, the most commonly failing pharmacokinetic parameter was Cmax. The data from these non-pivotal BE studies indicate that inadequate BE study design can lead to failure of the BE on the same formulation. Also, the non-pivotal BE studies on formulations different from the TBM formulation help us link the formulation design to the product performance in vivo. This article is open to POST-PUBLICATION REVIEW. Registered readers (see "For Readers") may comment by clicking on ABSTRACT on the issue's contents page.
Centrosome centering and decentering by microtubule network rearrangement
Letort, Gaëlle; Nedelec, Francois; Blanchoin, Laurent; Théry, Manuel
2016-01-01
The centrosome is positioned at the cell center by pushing and pulling forces transmitted by microtubules (MTs). Centrosome decentering is often considered to result from asymmetric, cortical pulling forces exerted in particular by molecular motors on MTs and controlled by external cues affecting the cell cortex locally. Here we used numerical simulations to investigate the possibility that it could equally result from the redistribution of pushing forces due to a reorientation of MTs. We first showed that MT gliding along cell edges and pivoting around the centrosome regulate MT rearrangement and thereby direct the spatial distribution of pushing forces, whereas the number, dynamics, and stiffness of MTs determine the magnitude of these forces. By modulating these parameters, we identified different regimes, involving both pushing and pulling forces, characterized by robust centrosome centering, robust off-centering, or “reactive” positioning. In the last-named conditions, weak asymmetric cues can induce a misbalance of pushing and pulling forces, resulting in an abrupt transition from a centered to an off-centered position. Taken together, these results point to the central role played by the configuration of the MTs on the distribution of pushing forces that position the centrosome. We suggest that asymmetric external cues should not be seen as direct driver of centrosome decentering and cell polarization but instead as inducers of an effective reorganization of the MT network, fostering centrosome motion to the cell periphery. PMID:27440925
Understanding Rasch Measurement: Partial Credit Model and Pivot Anchoring.
ERIC Educational Resources Information Center
Bode, Rita K.
2001-01-01
Describes the Rasch measurement partial credit model, what it is, how it differs from other Rasch models, and when and how to use it. Also describes the calibration of instruments with increasingly complex items. Explains pivot anchoring and illustrates its use and describes the effect of pivot anchoring on step calibrations, item hierarchy, and…
NASA Astrophysics Data System (ADS)
Park, Hyun Chan; Scheer, Evelyn; Witting, Karin; Hanika, Markus; Bender, Marcus; Hsu, Hao Chien; Yim, Dong Kil
2015-11-01
By controlling a thin indium tin oxide (ITO), indium zinc oxide interface layer between gate insulator and indium gallium zinc oxide (IGZO), the thin-film transistor (TFT) performance can reach higher mobility as conventional IGZO as well as superior stability. For large-area display application, Applied Materials static PVD array coater (Applied Materials GmbH & Co. KG, Alzenau, Germany) using rotary targets has been developed to enable uniform thin layer deposition in display industry. Unique magnet motion parameter optimization in Pivot sputtering coater is shown to provide very uniform thin ITO layer to reach TFT performance with high mobility, not only on small scale, but also on Gen8.5 (2500 × 2200 mm glass size) production system.
Mesofluidic controlled robotic or prosthetic finger
Lind, Randall F; Jansen, John F; Love, Lonnie J
2013-11-19
A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.
Investigation of a clamshell roll-out ejection concept
NASA Technical Reports Server (NTRS)
Hatakeyama, L. F.
1971-01-01
The equations for the motion, forces, and couples generated by clamshells released from spinning sounding rockets in accordance with a roll-out ejection concept are presented. The application of these equations to a study of a system for the Javelin rocket vehicle is discussed. The roll-out ejection concept advocated requires that each deploying clamshell be pivoted about an axis at its trailing edge located in the system sectioning plane. Clamshell despinning is a consequence of this deployment since the pivotal rate is in opposition to the rocket vehicle spin. The energy required by the deployment is derived largely from the rotational energy of the clamshell. Thus, the rocket vehicle will not be significantly despun by this kind of clamshell deployment. This ejection concept also permits a system design which makes it possible to limit clamshell angular motion to rotation about that one of its centroidal principal axes which is brought into parallelism with the rocket vehicle longitudinal axis. Also, by equalizing the moments of inertia about the other centroidal principal axes, the roll-out motion can be decoupled from any extraneous angular motion about these axes.
Improving Safe Consumer Transfers in a Day Treatment Setting Using Training and Feedback
Austin, John; Rost, Kristen; Stanley, Leslie
2011-01-01
An intervention package that included employee training, supervisory feedback, and graphic feedback was developed to increase employees' safe patient-transfers at a day treatment center for adults with disabilities. The intervention was developed based on the center's results from a Performance Diagnostic Checklist (PDC), which focused on antecedents, equipment and processes, knowledge and skills, and consequences related to patient-transfers. A multiple baseline (MBL) across two lifts (pivot and trunk), with one lift (side) remaining in baseline was used to evaluate the effects of the treatment package on three lifts commonly used by three health-care workers. The results indicated a substantial increase in the overall safe performance of the three lifts. The mean increase for group safety performance following intervention was 34% and 29% over baseline measures for the two target transfers, and 28% over baseline measures for the nontargeted transfer. The implications of these findings suggest that in settings where patient transfers are frequent and injuries are likely to occur (e.g., hospitals, day treatment centers), safe lifting and transferring behaviors can improve with an efficient and cost-effective intervention. PMID:22649577
Method and system for dynamic probabilistic risk assessment
NASA Technical Reports Server (NTRS)
Dugan, Joanne Bechta (Inventor); Xu, Hong (Inventor)
2013-01-01
The DEFT methodology, system and computer readable medium extends the applicability of the PRA (Probabilistic Risk Assessment) methodology to computer-based systems, by allowing DFT (Dynamic Fault Tree) nodes as pivot nodes in the Event Tree (ET) model. DEFT includes a mathematical model and solution algorithm, supports all common PRA analysis functions and cutsets. Additional capabilities enabled by the DFT include modularization, phased mission analysis, sequence dependencies, and imperfect coverage.
Design of a Hypermedia-Based Educating System for the Construction of Knowledge
1989-09-01
the variety they confront, promote short-term learning . This thesis provides the required background for developing an educating system which promotes...an effective educating system stems frm ever-increasing requirements for learning . Ine Total Quality Management (TQM) program, a Department of Defense...Japan has realized that best efforts ’nly pay off when the workforce is properly educated . Learning has become a pivotal element in the Japanese
Evolution of JAK-STAT Pathway Components: Mechanisms and Role in Immune System Development
Liongue, Clifford; O'Sullivan, Lynda A.; Trengove, Monique C.; Ward, Alister C.
2012-01-01
Background Lying downstream of a myriad of cytokine receptors, the Janus kinase (JAK) – Signal transducer and activator of transcription (STAT) pathway is pivotal for the development and function of the immune system, with additional important roles in other biological systems. To gain further insight into immune system evolution, we have performed a comprehensive bioinformatic analysis of the JAK-STAT pathway components, including the key negative regulators of this pathway, the SH2-domain containing tyrosine phosphatase (SHP), Protein inhibitors against Stats (PIAS), and Suppressor of cytokine signaling (SOCS) proteins across a diverse range of organisms. Results Our analysis has demonstrated significant expansion of JAK-STAT pathway components co-incident with the emergence of adaptive immunity, with whole genome duplication being the principal mechanism for generating this additional diversity. In contrast, expansion of upstream cytokine receptors appears to be a pivotal driver for the differential diversification of specific pathway components. Conclusion Diversification of JAK-STAT pathway components during early vertebrate development occurred concurrently with a major expansion of upstream cytokine receptors and two rounds of whole genome duplications. This produced an intricate cell-cell communication system that has made a significant contribution to the evolution of the immune system, particularly the emergence of adaptive immunity. PMID:22412924
Wastewater heat recovery method and apparatus
Kronberg, J.W.
1991-01-01
This invention is comprised of a heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.
Wastewater heat recovery apparatus
Kronberg, James W.
1992-01-01
A heat recovery system with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature.
Wastewater heat recovery apparatus
Kronberg, J.W.
1992-09-01
A heat recovery system is described with a heat exchanger and a mixing valve. A drain trap includes a heat exchanger with an inner coiled tube, baffle plate, wastewater inlet, wastewater outlet, cold water inlet, and preheated water outlet. Wastewater enters the drain trap through the wastewater inlet, is slowed and spread by the baffle plate, and passes downward to the wastewater outlet. Cold water enters the inner tube through the cold water inlet and flows generally upward, taking on heat from the wastewater. This preheated water is fed to the mixing valve, which includes a flexible yoke to which are attached an adjustable steel rod, two stationary zinc rods, and a pivoting arm. The free end of the arm forms a pad which rests against a valve seat. The rods and pivoting arm expand or contract as the temperature of the incoming preheated water changes. The zinc rods expand more than the steel rod, flexing the yoke and rotating the pivoting arm. The pad moves towards the valve seat as the temperature of the preheated water rises, and away as the temperature falls, admitting a variable amount of hot water to maintain a nearly constant average process water temperature. 6 figs.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Burner Assembly Showing Arms and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment 6 Figure 6 to Part 1633... and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Burner Assembly Showing Arms and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment 6 Figure 6 to Part 1633... and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Burner Assembly Showing Arms and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment 6 Figure 6 to Part 1633... and Pivots (Shoulder Screws), in Relation to, Portable Frame Allowing Burner Height Adjustment...
Central Facilities Area Sewage Lagoon Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Mark R.
2013-12-01
The Central Facilities Area (CFA), located in Butte County, Idaho, at the Idaho National Laboratory has an existing wastewater system to collect and treat sanitary wastewater and non-contact cooling water from the facility. The existing treatment facility consists of three cells: Cell #1 has a surface area of 1.7 acres, Cell #2 has a surface area of 10.3 acres, and Cell #3 has a surface area of 0.5 acres. If flows exceed the evaporative capacity of the cells, wastewater is discharged to a 73.5-acre land application site that uses a center-pivot irrigation sprinkler system. As flows at CFA have decreasedmore » in recent years, the amount of wastewater discharged to the land application site has decreased from 13.64 million gallons in 2004 to no discharge in 2012 and 2013. In addition to the decreasing need for land application, approximately 7.7 MG of supplemental water was added to the system in 2013 to maintain a water level and prevent the clay soil liners in the cells from drying out and “cracking.” The Idaho National Laboratory is concerned that the sewage lagoons and land application site may be oversized for current and future flows. A further concern is the sustainability of the large volumes of supplemental water that are added to the system according to current operational practices. Therefore, this study was initiated to evaluate the system capacity, operational practices, and potential improvement alternatives, as warranted.« less
Position specific morphological characteristics of top-level male handball players.
Srhoj, V; Marinović, M; Rogulj, N
2002-06-01
With the aim of determining the common morphological features of senior male handball players and of analyzing their specificities i.e. the probable variation between the four playing positions (back court players, wings, pivots, goalkeepers), 25 anthropometric measures were applied to the sample of 49 players, members of three top-quality handball teams. The basic descriptive parameters were calculated and then an analysis of variance and a cluster analysis were performed. A mesomorphic, athletic body- type was obtained with a marked longitudinal skeleton dimensionality, but also with a balanced ratio between the skeletal system and muscle mass and with low values of subcutaneous fat tissue. Back court players and goalkeepers are superior in terms of outstanding skeletal dimensions and circumferences. Line players, i.e. wings and pivots, have somewhat lower longitudinal measures, whereas pronounced voluminosity and a slightly higher fat tissue value differentiate pivots from players in other positions. Cluster analysis revealed a greater homogeneity in the morphological profiles of the samples of line players (wings and pivots) than in the profiles of backs or goalkeepers. The obtained position-related differences in morphological characteristics of players suggest that the experienced players from the sample were earlier successfully subjected to the selection process and oriented to a particular playing position because of the observed correspondence between their body-type and specific kinesiological demands of the position in question. Therefore, in top-quality team-handball it would be recommendable to select players whose morphological profiles are as compatible as possible with positional specificities in the demand for the game.
NASA Astrophysics Data System (ADS)
Sakota, Daisuke; Fujiwara, Tatsuki; Ohuchi, Katsuhiro; Kuwana, Katsuyuki; Yamazaki, Hiroyuki; Kosaka, Ryo; Maruyama, Osamu
2018-02-01
We developed an optical detector of thrombus formed on the pivot bearing of an extracorporeal centrifugal blood pump (MERA HCF-MP23; Senko Medical Instrument Mfg. Co., Ltd., Tokyo, Japan) which is frequently used for long-term extracorporeal circulation support to bridge to an implantable artificial heart, which in turn is used for bridge to heart transplantation in Japan. In this study, we investigated the quantitative performance of the thrombus formation in acute animal experiments. A total of three experiments of extracorporeal left ventricular assist using Japanese specific pathogen-free pigs were conducted. The optical fibers were set in the pump driver unit. The incident light at nearinfrared wavelength aiming at the pivot bearing and the resulting scattered light were guided to respective fibers. The detected signal was analyzed to obtain thrombus formation level (TFL) calculated by a specially developed software. When the increase in TFL was confirmed, the pump was exchanged and the extracorporeal circulation was restarted. The number of pump exchanges were four times at each experiment so a total of twelve pumps were evaluated. 3-dimentional data surrounding the pivot bearing and the adhered thrombus was captured by a 3-dimantional surface measurement system to calculate the thrombus surface area (TSA) formed on the pivot bearing. As a result, the correlation coefficient between TFL and TSA was 0.878. The accuracy of TSA estimated by the optical detector was 3.6+/-2.3 mm2. This was small enough to not have the pump exchanged in clinical judgement. The developed detector would be useful for optimal anti-coagulation management.
ERIC Educational Resources Information Center
Nugent, J. Kevin
2015-01-01
The period covering the first 3 months of life consists of a series of pivotal, life-changing transitions for the infant, for the parents, and for the emerging parent-child relationship. The Newborn Behavioral Observations (NBO) system is a relationship-based tool that offers individualized information to parents about their baby's communication…
NADPH Oxidase Deficiency: A Multisystem Approach
Cicalese, Maria Pia; Delmonte, Ottavia; Migliavacca, Maddalena; Cirillo, Emilia; Violi, Francesco
2017-01-01
The immune system is a complex system able to recognize a wide variety of host agents, through different biological processes. For example, controlled changes in the redox state are able to start different pathways in immune cells and are involved in the killing of microbes. The generation and release of ROS in the form of an “oxidative burst” represent the pivotal mechanism by which phagocytic cells are able to destroy pathogens. On the other hand, impaired oxidative balance is also implicated in the pathogenesis of inflammatory complications, which may affect the function of many body systems. NADPH oxidase (NOX) plays a pivotal role in the production of ROS, and the defect of its different subunits leads to the development of chronic granulomatous disease (CGD). The defect of the different NOX subunits in CGD affects different organs. In this context, this review will be focused on the description of the effect of NOX2 deficiency in different body systems. Moreover, we will also focus our attention on the novel insight in the pathogenesis of immunodeficiency and inflammation-related manifestations and on the protective role of NOX2 deficiency against the development of atherosclerosis. PMID:29430280
Brown, Alisa; Uneri, Ali; Silva, Tharindu De; Manbachi, Amir; Siewerdsen, Jeffrey H
2018-04-01
Dynamic reference frames (DRFs) are a common component of modern surgical tracking systems; however, the limited number of commercially available DRFs poses a constraint in developing systems, especially for research and education. This work presents the design and validation of a large, open-source library of DRFs compatible with passive, single-face tracking systems, such as Polaris stereoscopic infrared trackers (NDI, Waterloo, Ontario). An algorithm was developed to create new DRF designs consistent with intra- and intertool design constraints and convert to computer-aided design (CAD) files suitable for three-dimensional printing. A library of 10 such groups, each with 6 to 10 DRFs, was produced and tracking performance was validated in comparison to a standard commercially available reference, including pivot calibration, fiducial registration error (FRE), and target registration error (TRE). Pivot tests showed calibration error [Formula: see text], indistinguishable from the reference. FRE was [Formula: see text], and TRE in a CT head phantom was [Formula: see text], both equivalent to the reference. The library of DRFs offers a useful resource for surgical navigation research and could be extended to other tracking systems and alternative design constraints.
NASA Technical Reports Server (NTRS)
Fischell, D. R.; Mazique, J. C. (Inventor)
1981-01-01
A cervix-to-rectum measuring device to be used in the treatment of cervical cancer is described. It includes a handle and a probe pivotably connected to the handle for insertion in the rectum. The measuring device further includes means for coupling the handle to an intrauterine radiation applicator when the latter is positioned in the uterine cervix and the probe is inserted in the rectum to pivot the handle about the probe. A gear is provided which is adapted to pivot with the probe. A pinion pivotably connected to the handle meshes with the gear. A pointer fixed to the pinion is displaced in response to the pivoting of the handle about the probe, and this displacement can be read from a scale on the handle, providing an indication of the cervix-to-rectum distance.
Pivot tables for mortality analysis, or who needs life tables anyway?
Wesley, David; Cox, Hugh F
2007-01-01
Actuarial life-table analysis has long been used by life insurance medical directors for mortality abstraction from clinical studies. Ironically, today's life actuary instead uses pivot tables to analyze mortality. Pivot tables (a feature/function in MS Excel) collapse various dimensions of data that were previously arranged in an "experience study" format. Summary statistics such as actual deaths, actual and expected mortality (usually measured in dollars), and calculated results such as actual to expected ratios, are then displayed in a 2-dimensional grid. The same analytic process, excluding the dollar focus, can be used for clinical mortality studies. For raw survival data, especially large datasets, this combination of experience study data and pivot tables has clear advantages over life-table analysis in both accuracy and flexibility. Using the SEER breast cancer data, we compare the results of life-table analysis and pivot-table analysis.
Nelson, Jennifer
2014-01-01
The Office of Economic Opportunity-Population Council program is an example of a mid-twentieth-century federal government/private foundation cooperative effort to place family planning and maternal health at the center of a fight against entrenched poverty. These joint efforts were the trend in family planning and maternal health provision by the 1960s and had two overlapping but also contradictory goals. The first was to provide contraceptive services to poor women to reduce the numbers of poor children, thus relieving the poor of added mouths to feed. Popular fears of a population explosion, mounting welfare rolls, and an increase in the numbers of African Americans receiving welfare fueled this goal. The second aim, however, was to expand comprehensive maternal health services to help reduce poverty by increasing poor women's involvement in and control over the health institutions that could have significant impact on their lives. While the first goal pivoted on encouraging poor women to bear fewer children, the second sought to integrate poor women into community healthcare delivery systems.
Digital Earth reloaded - Beyond the next generation
NASA Astrophysics Data System (ADS)
Ehlers, M.; Woodgate, P.; Annoni, A.; Schade, S.
2014-02-01
Digital replicas (or 'mirror worlds') of complex entities and systems are now routine in many fields such as aerospace engineering; archaeology; medicine; or even fashion design. The Digital Earth (DE) concept as a digital replica of the entire planet occurs in Al Gore's 1992 book Earth in the Balance and was popularized in his speech at the California Science Center in January 1998. It played a pivotal role in stimulating the development of a first generation of virtual globes, typified by Google Earth that achieved many elements of this vision. Almost 15 years after Al Gore's speech, the concept of DE needs to be re-evaluated in the light of the many scientific and technical developments in the fields of information technology, data infrastructures, citizen?s participation, and earth observation that have taken place since. This paper intends to look beyond the next generation predominantly based on the developments of fields outside the spatial sciences, where concepts, software, and hardware with strong relationships to DE are being developed without referring to this term. It also presents a number of guiding criteria for future DE developments.
Garcia, E.J.; Christenson, T.R.; Polosky, M.A.
1999-06-29
A millimeter-sized machine, including electromagnetic circuits adapted to convert electromagnetic energy to mechanical energy, for engaging and operating external mechanical loads. A plurality of millimeter-sized magnetic actuators operate out of phase with each other to control a plurality of millimeter-sized structural elements to drive an external mechanical load. Each actuator is connected to a link. Each link, in turn, is connected to a drive pinion at another similar pivoting joint. When the magnetic actuators are energized, each drive pinion is then capable of driving a larger output gear in gear-like fashion to produce positive torque about the drive pinion center at all angular positions of the output gear. 29 figs.
NASA Technical Reports Server (NTRS)
Leavitt, L. D.
1985-01-01
An investigation was conducted at wind-off conditions in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance characteristics of a two-dimensional convergent nozzle with a thrust-vectoring capability up to 60 deg. Vectoring was accomplished by a downward rotation of a hinged upper convergent flap and a corresponding rotation of a center-pivoted lower convergent flap. The effects of geometric thrust-vector angle and upper-rotating-flap geometry on internal nozzle performance characteristics were investigated. Nozzle pressure ratio was varied from 1.0 (jet off) to approximately 5.0.
Garcia, Ernest J.; Christenson, Todd R.; Polosky, Marc A.
1999-01-01
A millimeter-sized machine, including electromagnetic circuits adapted to convert electromagnetic energy to mechanical energy, for engaging and operating external mechanical loads. A plurality of millimeter-sized magnetic actuators operate out of phase with each other to control a plurality of millimeter-sized structural elements to drive an external mechanical load. Each actuator is connected to a link. Each link, in turn, is connected to a drive pinion at another similar pivoting joint. When the magnetic actuators are energized, each drive pinion is then capable of driving a larger output gear in gear-like fashion to produce positive torque about the drive pinion center at all angular positions of the output gear.
Drag Characteristics of Several Towed Decelerator Models at Mach 3
NASA Technical Reports Server (NTRS)
Miserentino, Robert; Bohon, Herman L.
1970-01-01
An investigation has been made to determine the possibility of using toroid-membrane and wide-angle conical shapes as towed decelerators. Parameter variations were investigated which might render toroid-membrane models and wide-angle- cone models stable without loss of the high drag coefficients obtainable with sting-mounted models. The parameters varied included location of center of gravity, location of the pivot between the towline and the model, and configuration modifications of the aft end as the addition of a corner radius and the addition of a skirt. The toroid membrane can be made into a stable towed decelerator with a suitable configuration modification of the aft end.
General concepts in the management of a kidney transplant.
Ortiz-Heredia, Luis; Cangiano, Jose L
2011-01-01
The management of a kidney transplant patient is, in most cases, challenging and requires a multidisciplinary approach. For the physician caring for the patient it is imperative to have a broad knowledge regarding several concepts on their management, as they are increasingly faced with long-term care. Baseline rapport and accessibility provides a pivotal role in the treatment, monitoring and preventive measures in the kidney transplant patient. Currently, most aspects regarding patient management vary according to each transplant center. This article describes the importance of several medical issues directed towards the clinician aiming to improve awareness and expand knowledge, with the development of a systematic approach.
2007-01-30
KENNEDY SPACE CENTER, FLA. -- Workers on Launch Pad 39A get ready to begin the movement of the rotating service structure above them. The RSS has not been rotated for more than a year during the maintenance and upgrades on the pad. Some of the work included sandblasting the structure to remove rust and repainting. In addition, the RSS was jacked up and a new upper-bearing race assembly installed where the RSS pivots against the fixed service structure and a half-inch steel plate added. Pad 39A is being made ready for its first launch in four years, the upcoming STS-117 on March 15. Photo credit: NASA/George Shelton
ERIC Educational Resources Information Center
Espinoza, Roberta
2012-01-01
Minority students from low-income families face challenges in their daily lives that continually interfere with their academic performance as well as their ability to prepare for college. Although the educational system is viewed as "the great equalizer" that gives everyone an opportunity for upward social mobility, sociological and educational…
Communication and Cultural Change in University Technology Transfer
ERIC Educational Resources Information Center
Wright, David
2013-01-01
Faculty culture and communication networks are pivotal components of technology transfer on university campuses. Universities are focused upon diffusing technology to external clients and upon building structure and support systems to enhance technology transfer. However, engaging faculty members in technology transfer requires an internal…
Bock, Eduardo; Ribeiro, Adriana; Silva, Maxwell; Antunes, Pedro; Fonseca, Jeison; Legendre, Daniel; Leme, Juliana; Arruda, Celso; Biscegli, José; Nicolosi, Denys; Andrade, Aron
2008-04-01
A new dual impeller centrifugal blood pump has been developed as a research collaboration between Baylor College of Medicine and Institute Dante Pazzanese of Cardiology for long-term left ventricle assist device (LVAD). A design feature of this new pump is a dual impeller that aims to minimize a stagnant flow pattern around the inlet port. Several different materials were tested in order to adopt a double pivot bearing design originally developed by Prof. Dr. Yukihiko Nosé from Baylor College of Medicine. Hydraulic performance tests were conducted with two different inlet ports' angle configurations 30 degrees and 45 degrees . Pump with inlet port angle of 45 degrees achieved best values of pressure ahead and flow after 1800 rpm. Preliminary hemolysis tests were conducted using human blood. The pump showed good performance results and no alarming trace of hemolysis, proving to be a feasible long-term LVAD.
Double-bundle ACL reconstruction can improve rotational stability.
Yagi, Masayoshi; Kuroda, Ryosuke; Nagamune, Kouki; Yoshiya, Shinichi; Kurosaka, Masahiro
2007-01-01
Double-bundle anterior cruciate ligament (ACL) reconstruction reproduces anteromedial and posterolateral bundles, and thus has theoretical advantages over conventional single-bundle reconstruction in controlling rotational torque in vitro. However, its superiority in clinical practice has not been proven. We analyzed rotational stability with three reconstruction techniques in 60 consecutive patients who were randomly divided into three groups (double-bundle, anteromedial single-bundle, posterolateral single-bundle). In the reconstructive procedure, the hamstring tendon was harvested and used as a free tendon graft. Followup examinations were performed 1 year after surgery. Anteroposterior laxity of the knee was examined with a KT-1000 arthrometer, whereas rotatory instability, as elicited by the pivot shift test, was assessed using a new measurement system incorporating three-dimensional electromagnetic sensors. Routine clinical evaluations, including KT examination, demonstrated no differences among the three groups. However, using the new measurement system, patients with double-bundle ACL reconstruction showed better pivot shift control of complex instability than patients with anteromedial and posterolateral single-bundle reconstruction.
Hard turning micro-machine tool
DeVor, Richard E; Adair, Kurt; Kapoor, Shiv G
2013-10-22
A micro-scale apparatus for supporting a tool for hard turning comprises a base, a pivot coupled to the base, an actuator coupled to the base, and at least one member coupled to the actuator at one end and rotatably coupled to the pivot at another end. A tool mount is disposed on the at least one member. The at least one member defines a first lever arm between the pivot and the tool mount, and a second lever arm between the pivot and the actuator. The first lever arm has a length that is less than a length of the second lever arm. The actuator moves the tool mount along an arc.
Continuous wavelength tunable laser source with optimum positioning of pivot axis for grating
Pushkarsky, Michael; Amone, David F.
2010-06-08
A laser source (10) for generating a continuously wavelength tunable light (12) includes a gain media (16), an optical output coupler (36F), a cavity collimator (38A), a diffraction grating (30), a grating beam (54), and a beam attacher (56). The diffraction grating (30) is spaced apart from the cavity collimator (38A) and the grating (30) cooperates with the optical output coupler (36F) to define an external cavity (32). The grating (30) includes a grating face surface (42A) that is in a grating plane (42B). The beam attacher (56) retains the grating beam (54) and allows the grating beam (54) and the grating (30) to effectively pivot about a pivot axis (33) that is located approximately at an intersection of a pivot plane (50) and the grating plane (42B). As provided herein, the diffraction grating (30) can be pivoted about the unique pivot axis (33) to move the diffraction grating (30) relative to the gain media (16) to continuously tune the lasing frequency of the external cavity (32) and the wavelength of the output light (12) so that the output light (12) is mode hop free.
Gender differences in offaxis neuromuscular control during stepping under a slippery condition.
Lee, Song Joo; Ren, Yupeng; Geiger, François; Zhang, Li-Qun
2013-11-01
Females are at greater risks of musculoskeletal injuries than are males, which may be related to decreased neuromuscular control in axial and/or frontal planes, offaxis neuromuscular control. The objective of this study was to investigate gender differences in offaxis neuromuscular control during stepping under a slippery condition. Forty-three healthy subjects (21 males and 22 females) performed different stepping tasks under a slippery condition, namely, free pivoting task (FPT) to control axial plane pivoting, free sliding task (FST) to control frontal plane sliding, and free pivoting and sliding task (FPST) to control axial pivoting, and frontal sliding on a custom-made offaxis elliptical trainer. Compared to males, females showed significantly higher pivoting instability, higher max internal and external pivoting angles, higher mean max medial and lateral sliding distance, and higher entropy of time to peak EMG in the medial and lateral gastrocnemius muscles during the FPST and higher entropy of time to peak EMG in the lateral gastrocnemius muscle during the FPT and FST. The findings may help us understand potential injury risk factors associated with gender differences, and provide a basis for developing targeted neuromuscular training to improve offaxis neuromuscular control, and reduce musculoskeletal injuries associated with excessive offaxis loadings.
Statistical Short-Range Guidance for Peak Wind Speed Forecasts at Edwards Air Force Base, CA
NASA Technical Reports Server (NTRS)
Dreher, Joseph; Crawford, Winifred; Lafosse, Richard; Hoeth, Brian; Burns, Kerry
2008-01-01
The peak winds near the surface are an important forecast element for Space Shuttle landings. As defined in the Shuttle Flight Rules (FRs), there are peak wind thresholds that cannot be exceeded in order to ensure the safety of the shuttle during landing operations. The National Weather Service Spaceflight Meteorology Group (SMG) is responsible for weather forecasts for all shuttle landings. They indicate peak winds are a challenging parameter to forecast. To alleviate the difficulty in making such wind forecasts, the Applied Meteorology Unit (AMTJ) developed a personal computer based graphical user interface (GUI) for displaying peak wind climatology and probabilities of exceeding peak-wind thresholds for the Shuttle Landing Facility (SLF) at Kennedy Space Center. However, the shuttle must land at Edwards Air Force Base (EAFB) in southern California when weather conditions at Kennedy Space Center in Florida are not acceptable, so SMG forecasters requested that a similar tool be developed for EAFB. Marshall Space Flight Center (MSFC) personnel archived and performed quality control of 2-minute average and 10-minute peak wind speeds at each tower adjacent to the main runway at EAFB from 1997- 2004. They calculated wind climatologies and probabilities of average peak wind occurrence based on the average speed. The climatologies were calculated for each tower and month, and were stratified by hour, direction, and direction/hour. For the probabilities of peak wind occurrence, MSFC calculated empirical and modeled probabilities of meeting or exceeding specific 10-minute peak wind speeds using probability density functions. The AMU obtained and reformatted the data into Microsoft Excel PivotTables, which allows users to display different values with point-click-drag techniques. The GUT was then created from the PivotTables using Visual Basic for Applications code. The GUI is run through a macro within Microsoft Excel and allows forecasters to quickly display and interpret peak wind climatology and likelihoods in a fast-paced operational environment. A summary of how the peak wind climatologies and probabilities were created and an overview of the GUT will be presented.
Approaches Mediating Oxytocin Regulation of the Immune System.
Li, Tong; Wang, Ping; Wang, Stephani C; Wang, Yu-Feng
2016-01-01
The hypothalamic neuroendocrine system is mainly composed of the neural structures regulating hormone secretion from the pituitary gland and has been considered as the higher regulatory center of the immune system. Recently, the hypothalamo-neurohypophysial system (HNS) emerged as an important component of neuroendocrine-immune network, wherein the oxytocin (OT)-secreting system (OSS) plays an essential role. The OSS, consisting of OT neurons in the supraoptic nucleus, paraventricular nucleus, their several accessory nuclei and associated structures, can integrate neural, endocrine, metabolic, and immune information and plays a pivotal role in the development and functions of the immune system. The OSS can promote the development of thymus and bone marrow, perform immune surveillance, strengthen immune defense, and maintain immune homeostasis. Correspondingly, OT can inhibit inflammation, exert antibiotic-like effect, promote wound healing and regeneration, and suppress stress-associated immune disorders. In this process, the OSS can release OT to act on immune system directly by activating OT receptors or through modulating activities of other hypothalamic-pituitary-immune axes and autonomic nervous system indirectly. However, our understandings of the role of the OSS in neuroendocrine regulation of immune system are largely incomplete, particularly its relationship with other hypothalamic-pituitary-immune axes and the vasopressin-secreting system that coexists with the OSS in the HNS. In addition, it remains unclear about the relationship between the OSS and peripherally produced OT in immune regulation, particularly intrathymic OT that is known to elicit central immunological self-tolerance of T-cells to hypophysial hormones. In this work, we provide a brief review of current knowledge of the features of OSS regulation of the immune system and of potential approaches that mediate OSS coordination of the activities of entire neuroendocrine-immune network.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Burner Assembly Showing Arms and Pivots (Shoulder Screws) in Relation to Portable Frame Allowing Burner Height Adjustment 6 Figure 6 to Part 1633... and Pivots (Shoulder Screws) in Relation to Portable Frame Allowing Burner Height Adjustment ER15MR06...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Burner Assembly Showing Arms and Pivots (Shoulder Screws) in Relation to, Portable Frame Allowing Burner Height Adjustment 6 Figure 6 to Part 1633... and Pivots (Shoulder Screws) in Relation to, Portable Frame Allowing Burner Height Adjustment ER15MR06...
Tool for use in lifting pin supported objects
NASA Technical Reports Server (NTRS)
Marzek, R. A.; Read, W. S. (Inventor)
1974-01-01
A tool for use in lifting a pin-supported, electronic package mounted in juxtaposition with the surface of an electronic circuit board is described. The tool is configured to be received beneath a pin-supported package and is characterized by a manually operable linkage, including an elongated, rigid link is supported for axial reciprocation and a pivotal link pinned to the body and supported for oscillation induced in response to axial motion imparted to the rigid link. A lifting plate is pivotally coupled to the distal end of the pivotal link so that oscillatory motion imparted to the pivotal link serves to move the plate vertically for elevating the plate into lifting engagement with the electronic package positioned thereabove.
Electrical servo actuator bracket. [fuel control valves on jet engines
NASA Technical Reports Server (NTRS)
Sawyer, R. V. (Inventor)
1981-01-01
An electrical servo actuator is mounted on a support arm which is allowed to pivot on a bolt through a fixed mounting bracket. The actuator is pivotally connected to the end of the support arm by a bolt which has an extension allowed to pass through a slot in the fixed mounting bracket. An actuator rod extends from the servo actuator to a crank arm which turns a control shaft. A short linear thrust of the rod pivots the crank arm through about 90 for full-on control with the rod contracted into the servo actuator, and full-off control when the rod is extended from the actuator. A spring moves the servo actuator and actuator rod toward the control crank arm once the actuator rod is fully extended in the full-off position. This assures the turning of the control shaft to a full-off position. A stop bolt and slot are provided to limit pivot motion. Once fully extended, the spring pivots the motion.
PIVOT: platform for interactive analysis and visualization of transcriptomics data.
Zhu, Qin; Fisher, Stephen A; Dueck, Hannah; Middleton, Sarah; Khaladkar, Mugdha; Kim, Junhyong
2018-01-05
Many R packages have been developed for transcriptome analysis but their use often requires familiarity with R and integrating results of different packages requires scripts to wrangle the datatypes. Furthermore, exploratory data analyses often generate multiple derived datasets such as data subsets or data transformations, which can be difficult to track. Here we present PIVOT, an R-based platform that wraps open source transcriptome analysis packages with a uniform user interface and graphical data management that allows non-programmers to interactively explore transcriptomics data. PIVOT supports more than 40 popular open source packages for transcriptome analysis and provides an extensive set of tools for statistical data manipulations. A graph-based visual interface is used to represent the links between derived datasets, allowing easy tracking of data versions. PIVOT further supports automatic report generation, publication-quality plots, and program/data state saving, such that all analysis can be saved, shared and reproduced. PIVOT will allow researchers with broad background to easily access sophisticated transcriptome analysis tools and interactively explore transcriptome datasets.
Haider, Adil H; Hashmi, Zain G; Gupta, Sonia; Zafar, Syed Nabeel; David, Jean-Stephane; Efron, David T; Stevens, Kent A; Zafar, Hasnain; Schneider, Eric B; Voiglio, Eric; Coimbra, Raul; Haut, Elliott R
2014-08-01
National trauma registries have helped improve patient outcomes across the world. Recently, the idea of an International Trauma Data Bank (ITDB) has been suggested to establish global comparative assessments of trauma outcomes. The objective of this study was to determine whether global trauma data could be combined to perform international outcomes benchmarking. We used observed/expected (O/E) mortality ratios to compare two trauma centers [European high-income country (HIC) and Asian lower-middle income country (LMIC)] with centers in the North American National Trauma Data Bank (NTDB). Patients (≥16 years) with blunt/penetrating injuries were included. Multivariable logistic regression, adjusting for known predictors of trauma mortality, was performed. Estimates were used to predict the expected deaths at each center and to calculate O/E mortality ratios for benchmarking. A total of 375,433 patients from 301 centers were included from the NTDB (2002-2010). The LMIC trauma center had 806 patients (2002-2010), whereas the HIC reported 1,003 patients (2002-2004). The most important known predictors of trauma mortality were adequately recorded in all datasets. Mortality benchmarking revealed that the HIC center performed similarly to the NTDB centers [O/E = 1.11 (95% confidence interval (CI) 0.92-1.35)], whereas the LMIC center showed significantly worse survival [O/E = 1.52 (1.23-1.88)]. Subset analyses of patients with blunt or penetrating injury showed similar results. Using only a few key covariates, aggregated global trauma data can be used to adequately perform international trauma center benchmarking. The creation of the ITDB is feasible and recommended as it may be a pivotal step towards improving global trauma outcomes.
Remote controlled vacuum joint closure mechanism
Doll, D.W.; Hager, E.R.
1984-02-22
A remotely operable and maintainable vacuum joint closure mechanism for a noncircular aperture is disclosed. The closure mechanism includes an extendible bellows coupled at one end to a noncircular duct and at its other end to a flange assembly having sealed grooves for establishing a high vacuum seal with the abutting surface of a facing flange which includes an aperture forming part of the system to be evacuated. A plurality of generally linear arrangements of pivotally coupled linkages and piston combinations are mounted around the outer surface of the duct and aligned along the length thereof. Each of the piston/linkage assemblies is adapted to engage the flange assembly by means of a respective piston and is further coupled to a remote controlled piston drive shaft to permit each of the linkages positioned on a respective flat outer surface of the duct to simultaneously and uniformly displace a corresponding piston and the flange assembly with which it is in contact along the length of the duct in extending the bellows to provide a high vacuum seal between the movable flange and the facing flange. A plurality of latch mechanisms are also pivotally mounted on the outside of the duct. A first end of each of the latch mechanisms is coupled to a remotely controlled latch control shaft for displacing the latch mechanism about its pivot point. In response to the pivoting displacement of the latch mechanism, a second end thereof is displaced so as to securely engage the facing flange and maintain the high vacuum seal established by the displacement of the flange assembly and extension of the bellows without displacing the entire duct.
Graphical Language Games: Interactional Constraints on Representational Form
ERIC Educational Resources Information Center
Healey, Patrick G. T.; Swoboda, Nik; Umata, Ichiro; King, James
2007-01-01
The emergence of shared symbol systems is considered to be a pivotal moment in human evolution and human development. These changes are normally explained by reference to changes in people's internal cognitive processes. We present 2 experiments which provide evidence that changes in the external, collaborative processes that people use to…
Religion, Modernity and Social Rights in European Education
ERIC Educational Resources Information Center
Zambeta, Evie
2008-01-01
Religion, as social construct and institutional reality, has played a pivotal role in shaping European societies. In spite of the impact of Enlightenment theories in the formation of European modernity, institutionalized religions and established churches have managed to maintain their influence in the public domain. Educational systems, the par…
Ontology-Based Learner Categorization through Case Based Reasoning and Fuzzy Logic
ERIC Educational Resources Information Center
Sarwar, Sohail; García-Castro, Raul; Qayyum, Zia Ul; Safyan, Muhammad; Munir, Rana Faisal
2017-01-01
Learner categorization has a pivotal role in making e-learning systems a success. However, learner characteristics exploited at abstract level of granularity by contemporary techniques cannot categorize the learners effectively. In this paper, an architecture of e-learning framework has been presented that exploits the machine learning based…
Implementing Collaborative Design in the Next Series of eLearning Platforms
ERIC Educational Resources Information Center
Kropf, Dorothy
2013-01-01
Collaborative design empowers learning management system (LMS) providers and end users (online students) to develop a vibrant teaching and learning community. Successful periodic collaborations utilizing collaborative web tools between these two pivotal groups can produce the next series of eLearning platforms that are fertile grounds for…
Resilient organizations: matrix model and service line management.
Westphal, Judith A
2005-09-01
Resilient organizations modify structures to meet the demands of the marketplace. The author describes a structure that enables multihospital organizations to innovate and rapidly adapt to changes. Service line management within a matrix model is an evolving organizational structure for complex systems in which nurses are pivotal members.
NASA Astrophysics Data System (ADS)
Rubio, Rafael M.; Salamanca, Juan J.
2018-07-01
The dynamics of external force free motion of pendulums on surfaces of constant Gaussian curvature is addressed when the pivot moves along a geodesic obtaining the Lagrangian of the system. As an application it is possible the study of elastic and quantum pendulums.
ERIC Educational Resources Information Center
Gordon, Dan
2011-01-01
In the 2007 report, "Maximizing the Impact: The Pivotal Role of Technology in a 21st Century Education System," a task force of leading employers, education technology advocates, and educators concluded that schools were barely using technology, much less developing the tech skills needed of those entering the workplace. The report was a loud,…
Empowering Principals to Lead and Manage Public Schools Effectively in the 21st Century
ERIC Educational Resources Information Center
Mestry, Raj
2017-01-01
Globally, education systems have been affected by radical social, political and economic changes. Although school principals play a pivotal role in improving student learning and attaining educational outcomes, they work under strenuous conditions to deal with multifaceted transformational issues. Principals experience great difficulty in coping…
NASA Technical Reports Server (NTRS)
Mayall, S. D.
1974-01-01
Bearing provides continuous, smooth movement of the cat's-eye mirror, eliminating wear and deterioration of bearing surface and resulting oscillation effects in servo system. Design features self-aligning configuration; single-point, pivotal pad mounting, having air passage through it; and design of pads that allows for precise control of discharge path of air from pads.
Strategic School Funding for Improved Student Achievement
ERIC Educational Resources Information Center
Chambers, Jay G.; Brown, James R.; Levin, Jesse; Jubb, Steve; Harper, Dorothy; Tolleson, Ray; Manship, Karen
2010-01-01
This article features Strategic School Funding for Results (SSFR) project, a new joint initiative of the American Institutes for Research (AIR) and Pivot Learning Partners (PLP) aimed at improving school finance, human resources, and management systems in large urban school districts. The goal of the project is to develop and implement more…
Stress optimization of leaf-spring crossed flexure pivots for an active Gurney flap mechanism
NASA Astrophysics Data System (ADS)
Freire Gómez, Jon; Booker, Julian D.; Mellor, Phil H.
2015-04-01
The EU's Green Rotorcraft programme is pursuing the development of a functional and airworthy Active Gurney Flap (AGF) for a full-scale helicopter rotor blade. Interest in the development of this `smart adaptive rotor blade' technology lies in its potential to provide a number of aerodynamic benefits, which would in turn translate into a reduction in fuel consumption and noise levels. The AGF mechanism selected employs leaf-spring crossed flexure pivots. These provide important advantages over bearings as they are not susceptible to seizing and do not require maintenance (i.e. lubrication or cleaning). A baseline design of this mechanism was successfully tested both in a fatigue rig and in a 2D wind tunnel environment at flight-representative deployment schedules. For full validation, a flight test would also be required. However, the severity of the in-flight loading conditions would likely compromise the mechanical integrity of the pivots' leaf-springs in their current form. This paper investigates the scope for stress reduction through three-dimensional shape optimization of the leaf-springs of a generic crossed flexure pivot. To this end, a procedure combining a linear strain energy formulation, a parametric leaf-spring profile definition and a series of optimization algorithms is employed. The resulting optimized leaf-springs are proven to be not only independent of the angular rotation at which the pivot operates, but also linearly scalable to leaf-springs of any length, minimum thickness and width. Validated using non-linear finite element analysis, the results show very significant stress reductions relative to pivots with constant cross section leaf-springs, of up to as much as 30% for the specific pivot configuration employed in the AGF mechanism. It is concluded that shape optimization offers great potential for reducing stress in crossed flexure pivots and, consequently, for extending their fatigue life and/or rotational range.
Schuijt, Tim J.; Bakhtiari, Kamran; Daffre, Sirlei; DePonte, Kathleen; Wielders, Simone J.H.; Marquart, J. Arnoud; Hovius, Joppe W.; van der Poll, Tom; Fikrig, Erol; Bunce, Matthew W.; Camire, Rodney M.; Nicolaes, Gerry A.F.; Meijers, Joost C.M.; van 't Veer, Cornelis
2013-01-01
Background Generation of active procoagulant cofactor FVa and its subsequent association with the enzyme FXa to form the prothrombinase complex is a pivotal initial event in blood coagulation and has been the subject of investigative effort, speculation and controversy. The current paradigm assumes that FV activation is initiated by limited proteolysis by traces of (meizo) thrombin. Methods and Results Recombinant tick salivary protein TIX-5 was produced and anticoagulant properties were studied using plasma, whole blood and purified systems. Here we report that TIX-5 specifically inhibits FXa-mediated FV activation involving the B-domain of FV and show that FXa activation of FV is pivotal for plasma and blood clotting. In line, tick feeding is impaired on TIX-5 immune rabbits displaying the in vivo importance of TIX-5. Conclusions Our data elucidate a unique molecular mechanism by which ticks inhibit the host's coagulation system. Based on our data we propose a revised blood coagulation scheme wherein direct FXa-mediated FV activation occurs in the initiation phase during which thrombin-mediated FV activation is restrained by fibrinogen and inhibitors. PMID:23817575
Flexible pipe crawling device having articulated two axis coupling
Zollinger, William T.
1994-01-01
An apparatus for moving through the linear and non-linear segments of piping systems. The apparatus comprises a front leg assembly, a rear leg assembly, a mechanism for extension and retraction of the front and rear leg assembles with respect to each other, such as an air cylinder, and a pivoting joint. One end of the flexible joint attaches to the front leg assembly and the other end to the air cylinder, which is also connected to the rear leg assembly. The air cylinder allows the front and rear leg assemblies to progress through a pipe in "inchworm" fashion, while the joint provides the flexibility necessary for the pipe crawler to negotiate non-linear piping segments. The flexible connecting joint is coupled with a spring-force suspension system that urges alignment of the front and rear leg assemblies with respect to each other. The joint and suspension system cooperate to provide a firm yet flexible connection between the front and rear leg assemblies to allow the pivoting of one with respect to the other while moving around a non-linear pipe segment, but restoring proper alignment coming out of the pipe bend.
Flexible pipe crawling device having articulated two axis coupling
Zollinger, W.T.
1994-05-10
An apparatus is described for moving through the linear and non-linear segments of piping systems. The apparatus comprises a front leg assembly, a rear leg assembly, a mechanism for extension and retraction of the front and rear leg assembles with respect to each other, such as an air cylinder, and a pivoting joint. One end of the flexible joint attaches to the front leg assembly and the other end to the air cylinder, which is also connected to the rear leg assembly. The air cylinder allows the front and rear leg assemblies to progress through a pipe in inchworm' fashion, while the joint provides the flexibility necessary for the pipe crawler to negotiate non-linear piping segments. The flexible connecting joint is coupled with a spring-force suspension system that urges alignment of the front and rear leg assemblies with respect to each other. The joint and suspension system cooperate to provide a firm yet flexible connection between the front and rear leg assemblies to allow the pivoting of one with respect to the other while moving around a non-linear pipe segment, but restoring proper alignment coming out of the pipe bend. 4 figures.
NASA Astrophysics Data System (ADS)
Weng, Hanli; Li, Youping
2017-04-01
The working principle, process device and test procedure of runner static balancing test method by weighting with three-pivot pressure transducers are introduced in this paper. Based on an actual instance of a V hydraulic turbine runner, the error and sensitivity of the three-pivot pressure transducer static balancing method are analysed. Suggestions about improving the accuracy and the application of the method are also proposed.
Simulator scene display evaluation device
NASA Technical Reports Server (NTRS)
Haines, R. F. (Inventor)
1986-01-01
An apparatus for aligning and calibrating scene displays in an aircraft simulator has a base on which all of the instruments for the aligning and calibrating are mounted. Laser directs beam at double right prism which is attached to pivoting support on base. The pivot point of the prism is located at the design eye point (DEP) of simulator during the aligning and calibrating. The objective lens in the base is movable on a track to follow the laser beam at different angles within the field of vision at the DEP. An eyepiece and a precision diopter are movable into a position behind the prism during the scene evaluation. A photometer or illuminometer is pivotable about the pivot into and out of position behind the eyepiece.
Rasmussen, Matthew T; Nitri, Marco; Williams, Brady T; Moulton, Samuel G; Cruz, Raphael Serra; Dornan, Grant J; Goldsmith, Mary T; LaPrade, Robert F
2016-03-01
Recent investigations have described the structural and functional behavior of the anterolateral ligament (ALL) of the knee through pull-apart and isolated sectioning studies. However, the secondary stabilizing role of the ALL in the setting of a complete anterior cruciate ligament (ACL) tear has not been fully defined for common simulated clinical examinations, such as the pivot-shift, anterior drawer, and internal rotation tests. Combined sectioning of the ALL and ACL would lead to increased internal rotation and increased axial plane translation during a pivot-shift test when compared with isolated sectioning of the ACL. Controlled laboratory study. Ten fresh-frozen human cadaveric knees were subjected to a simulated pivot-shift test with coupled 10-N·m valgus and 5-N·m internal rotation torques from 0° to 60° of knee flexion and a 5-N·m internal rotation torque and an 88-N anterior tibial load, both from 0° to 120° of knee flexion via a 6 degrees of freedom robotic system. Kinematic changes were measured and compared with the intact state for isolated sectioning of the ACL and combined sectioning of the ACL and ALL. Combined sectioning of the ACL and ALL resulted in a significant increase in axial plane tibial translation during a simulated pivot shift at 0°, 15°, 30°, and 60° of knee flexion and a significant increase in internal rotation at 0°, 15°, 30°, 45°, 60°, 75°, 90°, 105°, and 120° when compared with the intact and ACL-deficient states. Based on the model results, ALL sectioning resulted in an additional 2.1 mm (95% CI, 1.4-2.9 mm; P < .001) of axial plane translation during the pivot shift when compared with ACL-only sectioning, when pooling evidence over all flexion angles. Likewise, when subjected to IR torque, the ACL+ALL-deficient state resulted in an additional 3.2° of internal rotation (95% CI, 2.4°-4.1°; P < .001) versus the intact state, and the additional sectioning of the ALL increased internal rotation by 2.7° (95% CI, 1.8°-3.6°; P < .001) versus the ACL-deficient state. The results of this study confirm the ALL as an important lateral knee structure that provides rotatory stability to the knee. Specifically, the ALL was a significant secondary stabilizer throughout flexion during an applied internal rotation torque and simulated pivot-shift test in the context of an ACL-deficient knee. Residual internal rotation and a positive pivot shift after ACL reconstruction may be attributed to ALL injury. For these patients, surgical treatment of an ALL tear may be considered. © 2015 The Author(s).
ERIC Educational Resources Information Center
Cicero, Gayle M.
2010-01-01
Professional school counselors' leadership capacity may well play a pivotal role in educational reform in the twenty-first century. Crucial to the success of this vision, supported by the American School Counseling Association, is the perspective of system-level supervisors of school counselors. This exploratory qualitative study employed in-depth…
Apparatus for mounting photovoltaic power generating systems on buildings
Russell, Miles C [Lincoln, MA
2009-08-18
Rectangular photovoltaic (PV) modules are mounted on a building roof by mounting stands that are distributed in rows and columns. Each stand comprises a base plate and first and second different height brackets attached to opposite ends of the base plate. Each first and second bracket comprises two module-support members. One end of each module is pivotally attached to and supported by a first module-support member of a first bracket and a second module-support member of another first bracket. At its other end each module rests on but is connected by flexible tethers to module-support members of two different second brackets. The tethers are sized to allow the modules to pivot up away from the module-support members on which they rest to a substantially horizontal position in response to wind uplift forces.
Experimental determination of airplane mass and inertial characteristics
NASA Technical Reports Server (NTRS)
Wolowicz, C. H.; Yancey, R. B.
1974-01-01
Current practices are evaluated for experimentally determining airplane center of gravity, moments of inertia, and products of inertia. The techniques discussed are applicable to bodies other than airplanes. In pitching- and rolling-moment-of-inertia investigations with the airplane mounted on and pivoted about knife edges, the nonlinear spring moments that occur at large amplitudes of oscillation can be eliminated by using the proper spring configuration. The single-point suspension double-pendulum technique for obtaining yawing moments of inertia, products of inertia, and the inclination of the principal axis provides accurate results from yaw-mode oscillation data, provided that the sway-mode effects are minimized by proper suspension rig design. Rocking-mode effects in the data can be isolated.
Agrawal, Rina; Burt, Elizabeth; Homburg, Roy
2013-12-01
In the wake of political upheaval, the Human Fertilisation and Embryo Authority (HFEA) has faced increasing insecurity over its future as a pivotal regulatory body of fertility practices in the UK. HFEA regulates activities by means of licensing, audit, and inspection of fertility centers and maintaining the Code of Practice, which ensures the optimum undertaking of licensed activities by fertility centers. In 2009, amendments to the 1990 Act came into force representing an amalgamation of cumulative proposals, debates, and changes in legislation, which have shaped the world of reproductive medicine. The medical world has, in many cases, adapted to righteous political and social demands, and continues to evolve at a rapid rate. The HFEA has faced many regulatory challenges and changes, and through this study, we aim to provide an overview of some of these changes, particularly those during the last 10 years and the implications that they may have had to fertility practices.
Effective Nurse Communication With Type 2 Diabetes Patients: A Review.
Mulder, Bob C; Lokhorst, Anne Marike; Rutten, Guy E H M; van Woerkum, Cees M J
2015-08-01
Many type 2 diabetes mellitus patients have difficulties reaching optimal blood glucose control. With patients treated in primary care by nurses, nurse communication plays a pivotal role in supporting patient health. The twofold aim of the present review is to categorize common barriers to nurse-patient communication and to review potentially effective communication methods. Important communication barriers are lack of skills and self-efficacy, possibly because nurses work in a context where they have to perform biomedical examinations and then perform patient-centered counseling from a biopsychosocial approach. Training in patient-centered counseling does not seem helpful in overcoming this paradox. Rather, patient-centeredness should be regarded as a basic condition for counseling, whereby nurses and patients seek to cooperate and share responsibility based on trust. Nurses may be more successful when incorporating behavior change counseling based on psychological principles of self-regulation, for example, goal setting, incremental performance accomplishments, and action planning. © The Author(s) 2014.
Downing, Nicholas S; Shah, Nilay D; Neiman, Joseph H; Aminawung, Jenerius A; Krumholz, Harlan M; Ross, Joseph S
2016-04-14
Pivotal trials, the clinical studies that inform U.S. Food and Drug Administration (FDA) approval decisions, provide the foundational evidence supporting the safety and efficacy of novel therapeutics. We determined the representation of the elderly, women, and patients from racial and ethnic minorities in pivotal trials and whether the FDA is making subgroup efficacy analyses among these subpopulations available to the public. We conducted a cross-sectional study of novel therapeutics approved by the FDA between 2011 and 2013. Using publicly available FDA documents, we collected information on the demographic characteristics of pivotal trial participants (age ≥65 years, sex [male, female], race [white, black, Asian, other], and ethnicity [Hispanic, non-Hispanic]) and determined the availability of subgroup analyses by age, sex, race, and ethnicity. We identified 86 novel therapeutic that were approved by the FDA between 2011 and 2013 for 92 indications on the basis of 206 pivotal trials. The median age of pivotal trial patients was 53.1 years (interquartile range 40.6-60.6), and the mean proportion of patients ≥65 years of age was 28.9 % (95 % CI 23.5-34.4 %). Similar proportions of pivotal trial participants were male (mean 50.3 %, 95 % CI 45.3-55.2 %) and female (mean 49.7 %, 95 % CI 44.7-54.7 %). Most participants were white (mean 79.2 %, 95 % CI 75.9-82.6 %), while the mean proportion of black patients was 7.4 % (95 % CI 5.5-9.3 %), that of Asian patients was 7.4 % (95 % CI 5.2-9.7 %), and that of patients of other races was 5.9 % (95 % CI 4.4-7.5 %). Information about ethnicity was available for only 59.8 % of indications, and where such data were available, the mean proportion of Hispanic participants was 13.3 % (95 % CI 10.3-16.3 %). FDA reviewers performed and made available subgroup efficacy analyses by age, sex, and race for at least one of the pivotal trials used as the basis of approval for over 80 % of indications. Although women are equally represented in pivotal trials supporting recent novel therapeutic approvals by the FDA, elderly patients and those from racial and ethnic minorities are underrepresented. FDA reviewers generally perform subgroup efficacy analyses by age, sex, and race and make these subgroup analyses available to the public.
Re-use of pilot data and interim analysis of pivotal data in MRMC studies: a simulation study
NASA Astrophysics Data System (ADS)
Chen, Weijie; Samuelson, Frank; Sahiner, Berkman; Petrick, Nicholas
2017-03-01
Novel medical imaging devices are often evaluated with multi-reader multi-case (MRMC) studies in which radiologists read images of patient cases for a specified clinical task (e.g., cancer detection). A pilot study is often used to measure the effect size and variance parameters that are necessary for sizing a pivotal study (including sizing readers, non-diseased and diseased cases). Due to the practical difficulty of collecting patient cases or recruiting clinical readers, some investigators attempt to include the pilot data as part of their pivotal study. In other situations, some investigators attempt to perform an interim analysis of their pivotal study data based upon which the sample sizes may be re-estimated. Re-use of the pilot data or interim analyses of the pivotal data may inflate the type I error of the pivotal study. In this work, we use the Roe and Metz model to simulate MRMC data under the null hypothesis (i.e., two devices have equal diagnostic performance) and investigate the type I error rate for several practical designs involving re-use of pilot data or interim analysis of pivotal data. Our preliminary simulation results indicate that, under the simulation conditions we investigated, the inflation of type I error is none or only marginal for some design strategies (e.g., re-use of patient data without re-using readers, and size re-estimation without using the effect-size estimated in the interim analysis). Upon further verifications, these are potentially useful design methods in that they may help make a study less burdensome and have a better chance to succeed without substantial loss of the statistical rigor.
Hardy, Alexandre; Casabianca, Laurent; Hardy, Edouard; Grimaud, Olivier; Meyer, Alain
2017-04-01
The pivot shift test is quantified subjectively during assessment of patients presenting with suspected Anterior Cruciate Ligament (ACL) tears and has a low interobserver reproducibility. The Kinematic Rapid Assessment (KiRA) is a triaxial accelerometer that makes it possible to non-invasively quantify tibial acceleration during the pivot shift test. Abolishing pivot shift is considered to be a key element in surgical reconstruction but is incomplete in 25-38% of patients. Patients were included prospectively. Inclusion criteria were patients requiring ACL reconstruction associated with at least one of the following factors corresponding to the patient who have a high risk of rupture either by their sports activity, a failure case, or the notion of important rotational laxity: the patient practiced a competitive pivot-contact sport, revision ACL reconstruction (besides STG (semitendinosus-gracilis graft) repair), subjective explosive rotational laxity, Segond fracture, and TELOS value of >10 mm. Standardized pre- and postoperative pivot shift tests were immediately performed under anesthesia in both knees. Forty-three patients were included. Mean preoperative variations in tibial acceleration in the healthy and injured knees were 1.2 ± 0.1 and 2.7 ± 0.3 m/s 2 , respectively, p < 0.01. A statistically significant decrease in immediate postoperative mean variations in acceleration in the injured knee occurred: 1.5 ± 0.3 m/s 2 , p < 0.01. There was no longer any statistical difference between postoperative contralateral healthy knees and operated knees (n.s). Combined ACL reconstruction associated with anterolateral tenodesis suppress acute pathologic tibial acceleration in the pivot shift. III.
Focus collimator press for a collimator for gamma ray cameras
DOE Office of Scientific and Technical Information (OSTI.GOV)
York, R.N.; York, D.L.
A focus collimator press for collimators for gamma ray cameras is described comprising a pivot arm of fixed length mounted on a travelling pivot which is movable in the plane of a spaced apart work table surface in a direction toward and away from the work table. A press plate is carried at the opposite end of the fixed length pivot arm, and is maintained in registration with the same portion of the work table for pressing engagement with each undulating radiation opaque strip as it is added to the top of a collimator stack in process by movement ofmore » the travelling pivot inward toward the work table. This enables the press plate to maintain its relative position above the collimator stack and at the same time the angle of the press plate changes, becoming less acute in relation to the work table as the travelling pivot motes inwardly toward the work table. The fixed length of the pivot arm is substantially equal to the focal point of the converging apertures formed by each pair of undulating strips stacked together. Thus, the focal point of each aperture row falls substantially on the axis of the travelling pivot, and since it moves in the plane of the work table surface the focal point of each aperture row is directed to lie in the same common plane. When one of two collimator stacks made in this way is rotated 180 degrees and the two bonded together along their respective first strips, all focal points of every aperture row lie on the central axis of the completed collimator.« less
Enabling recruitment success in bariatric surgical trials: pilot phase of the By-Band-Sleeve study.
Paramasivan, S; Rogers, C A; Welbourn, R; Byrne, J P; Salter, N; Mahon, D; Noble, H; Kelly, J; Mazza, G; Whybrow, P; Andrews, R C; Wilson, C; Blazeby, J M; Donovan, J L
2017-11-01
Randomized controlled trials (RCTs) involving surgical procedures are challenging for recruitment and infrequent in the specialty of bariatrics. The pilot phase of the By-Band-Sleeve study (gastric bypass versus gastric band versus sleeve gastrectomy) provided the opportunity for an investigation of recruitment using a qualitative research integrated in trials (QuinteT) recruitment intervention (QRI). The QRI investigated recruitment in two centers in the pilot phase comparing bypass and banding, through the analysis of 12 in-depth staff interviews, 84 audio recordings of patient consultations, 19 non-participant observations of consultations and patient screening data. QRI findings were developed into a plan of action and fed back to centers to improve information provision and recruitment organization. Recruitment proved to be extremely difficult with only two patients recruited during the first 2 months. The pivotal issue in Center A was that an effective and established clinical service could not easily adapt to the needs of the RCT. There was little scope to present RCT details or ensure efficient eligibility assessment, and recruiters struggled to convey equipoise. Following presentation of QRI findings, recruitment in Center A increased from 9% in the first 2 months (2/22) to 40% (26/65) in the 4 months thereafter. Center B, commencing recruitment 3 months after Center A, learnt from the emerging issues in Center A and set up a special clinic for trial recruitment. The trial successfully completed pilot recruitment and progressed to the main phase across 11 centers. The QRI identified key issues that enabled the integration of the trial into the clinical setting. This contributed to successful recruitment in the By-Band-Sleeve trial-currently the largest in bariatric practice-and offers opportunities to optimize recruitment in other trials in bariatrics.
Fonseca, Fernando G A; Esmerino, Erick A; Filho, Elson R Tavares; Ferraz, Juliana P; da Cruz, Adriano G; Bolini, Helena M A
2016-05-01
Rapid sensory profiling methods have gained space in the sensory evaluation field. Techniques using direct analysis of the terms generated by consumers are considered easy to perform, without specific training requirements, thus improving knowledge about consumer perceptions on various products. This study aimed to determine the sensory profile of different commercial samples of chocolate ice cream, labeled as conventional and light or diet, using the "comment analysis" and "pivot profile" methods, based on consumers' perceptions. In the comment analysis task, consumers responded to 2 separate open questions describing the sensory attributes they liked or disliked in each sample. In the pivot profile method, samples were served in pairs (consisting of a coded sample and pivot), and consumers indicated the higher and lower intensity attributes in the target sample compared with the pivot. We observed that both methods were able to characterize the different chocolate ice cream samples using consumer perception, with high correlation results and configurational similarity (regression vector coefficient=0.917) between them. However, it is worth emphasizing that comment analysis is performed intuitively by consumers, whereas the pivot profile method showed high analytical and discriminative power even using consumers, proving to be a promising technique for routine application when classical descriptive methods cannot be used. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Abasic pivot substitution harnesses target specificity of RNA interference
Lee, Hye-Sook; Seok, Heeyoung; Lee, Dong Ha; Ham, Juyoung; Lee, Wooje; Youm, Emilia Moonkyung; Yoo, Jin Seon; Lee, Yong-Seung; Jang, Eun-Sook; Chi, Sung Wook
2015-01-01
Gene silencing via RNA interference inadvertently represses hundreds of off-target transcripts. Because small interfering RNAs (siRNAs) can function as microRNAs, avoiding miRNA-like off-target repression is a major challenge. Functional miRNA–target interactions are known to pre-require transitional nucleation, base pairs from position 2 to the pivot (position 6). Here, by substituting nucleotide in pivot with abasic spacers, which prevent base pairing and alleviate steric hindrance, we eliminate miRNA-like off-target repression while preserving on-target activity at ∼80–100%. Specifically, miR-124 containing dSpacer pivot substitution (6pi) loses seed-mediated transcriptome-wide target interactions, repression activity and biological function, whereas other conventional modifications are ineffective. Application of 6pi allows PCSK9 siRNA to efficiently lower plasma cholesterol concentration in vivo, and abolish potentially deleterious off-target phenotypes. The smallest spacer, C3, also shows the same improvement in target specificity. Abasic pivot substitution serves as a general means to harness the specificity of siRNA experiments and therapeutic applications. PMID:26679372
Fischer, William H.; Yoon, Kue H.
1984-04-10
A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed perpendicular to the direction of travel of the inner conductor/insulating support assembly.
New Learning: A Charter for Change in Education
ERIC Educational Resources Information Center
Kalantzis, Mary; Cope, Bill
2012-01-01
In this moment of tremendous change, investing in old ways of doing education is not the best way forward. In offering a Charter for Change we recognise that knowledge and learning will be pivotal to the social and personal transformations necessary to address the idiosyncratic challenges of our times. The transformed economic system emerging from…
ERIC Educational Resources Information Center
Petocz, Agnes; Keller, Peter E.; Stevens, Catherine J.
2008-01-01
In auditory warning design the idea of the strength of the association between sound and referent has been pivotal. Research has proceeded via constructing classification systems of signal-referent associations and then testing predictions about ease of learning of different levels of signal-referent relation strength across and within different…
Educator Discourses on ICT in Education: A Critical Analysis
ERIC Educational Resources Information Center
Bladergroen, Moira; Chigona, Wallace; Bytheway, Andy; Cox, Sanet; Dumas, Chris; van Zyl, Izak
2012-01-01
This paper presents a Critical Discourse Analysis (CDA) of Primary School Educators' dialogue on the use of ICT in an under-resourced schooling context. Educators play a pivotal role in the education system. Information and Communication Technology (ICT) interventions in schools will be effective only if educators are willing and able to…
ERIC Educational Resources Information Center
Tempelaar, Dirk T.; Rienties, Bart; Giesbers, Bas; Gijselaers, Wim H.
2015-01-01
Empirical studies into meaning systems surrounding implicit theories of intelligence typically entail two stringent assumptions: that different implicit theories and different effort beliefs represent opposite poles on a single scale, and that implicit theories directly impact the constructs as achievement goals and academic motivations. Through…
The Curriculum of Climate Change Education: A Case for Singapore
ERIC Educational Resources Information Center
Chang, Chew-Hung; Pascua, Liberty
2017-01-01
The inclusion of the climate change topic in the curriculum of school subjects in Singapore was pivotal, such that it positioned the discourse squarely in the structure of Singapore's education system. In an examination of the intersections and disjoints between state policies on climate change against the programmatic curriculum, results showed…
A Critical Approach and a Statistical Study to Leadership in University Education
ERIC Educational Resources Information Center
Goulionis, Yannis
2013-01-01
The higher education sub-sector of the entire education system is very important and plays pivotal role in all walks of life. Quality in the universities cannot be orchestrated without charismatic and effective administration doubled with management decision-making techniques. The study was aimed at evaluating the management techniques used in…
Landsat's role in ecological applications of remote sensing.
Warren B. Cohen; Samuel N. Goward
2004-01-01
Remote sensing, geographic information systems, and modeling have combined to produce a virtual explosion of growth in ecological investigations and applications that are explicitly spatial and temporal. Of all remotely sensed data, those acquired by landsat sensors have played the most pivotal role in spatial and temporal scaling. Modern terrestrial ecology relies on...
Investigation of a rotor system incorporating a constant lift tip
NASA Technical Reports Server (NTRS)
Mcveigh, M. A.; Rosenstein, H.; Bartie, K.; Mchugh, F. J.
1981-01-01
A wind tunnel test of a 16.8 ft. model of a rotor having passively controlled pivotable tips is described. Performance and vibratory hub load data are presented which compare the performance of the rotor with the tips free and fixed. A brief analysis of the experimental findings is included.
Hovis, Gregory L.; Erickson, Scott A.; Blackmon, Bruce L.
2002-01-01
A pipe crawler apparatus particularly useful for 3-inch and 4-inch diameter pipes is provided. The pipe crawler apparatus uses a gripping apparatus in which a free end of a piston rod is modified with a bearing retaining groove. Bearings, placed within the groove, are directed against a camming surface of three respective pivoting support members. The non-pivoting ends of the support members carry a foot-like gripping member that, upon pivoting of the support member, engages the interior wall of the pipe.
Vibration assessment for thrombus formation in the centrifugal pump.
Nakazawa, T; Makinouchi, K; Takami, Y; Glueck, J; Tayama, E; Nosé, Y
1997-04-01
To clarify the correlation of vibration and thrombus formation inside a rotary blood pump, 40 preliminary vibration studies were performed on pivot bearing centrifugal pumps. No such studies were found in the literature. The primary data acquisition equipment included an accelerometer (Isotron PE accelerometer, ENDEVCO, San Juan Capistrano, CA, U.S.A.), digitizing oscilloscope (TDS 420, Tektronix Inc., Pittsfield, MA, U.S.A.), and pivot bearing centrifugal pumps. The pump impeller was coupled magnetically to the driver magnet. The accelerometer was mounted on the top of the pump casing to sense radial and axial accelerations. To simulate the 3 common areas of thrombus formation, a piece of silicone rubber was attached to each of the following 3 locations as described: a circular shape on the center bottom of the impeller (CI), an eccentric shape on the bottom of the impeller (EI), and a circular shape on the center bottom casing (CC). A fast Fourier transform (FFT) method at 5 L/min against 100 mm Hg, with a pump rotating speed of 1,600 rpm was used. The frequency response of the vibration sensors used spans of 40 Hz to 2 kHz. The frequency domain was already integrated into the oscilloscope, allowing for comparison of the vibration results. The area of frequency domain at a radial direction was 206 +/- 12.7 mVHz in CI, 239.5 +/- 12.1 mVHz in EI, 365 +/- 12.9 mVHz in CC, and 163 +/- 7.9 mVHz in the control (control vs. CI p = 0.07, control vs. EI p < 0.001, control vs. CC p < 0.001, EI vs. CC p < 0.001, CI vs. CC p < 0.001). Three types of imitation thrombus formations were roughly distinguishable. These results suggested the possibility of detecting thrombus formation using vibration signals, and these studies revealed the usefulness of vibration monitoring to detect thrombus formation in a centrifugal pump.
NASA Technical Reports Server (NTRS)
Ferragut, Nelson J.
2005-01-01
A rugged iris mechanism has been designed to satisfy several special requirements, including a wide aperture in the "open" position, full obscuration in the "closed" position, ability to function in a cryogenic or other harsh environment, and minimization of friction through minimization of the number of components. An important element of the low-friction aspect of the design is maximization of the flatness of, and provision of small gaps between, adjacent iris blades. The tolerances of the design can be very loose, accommodating thermal expansions and contractions associated with large temperature excursions. The design is generic in that it is adaptable to a wide range of aperture sizes and can be implemented in a variety of materials to suit the thermal, optical, and mechanical requirements of various applications. The mechanism (see figure) includes an inner flat ring, an outer flat ring, and an even number of iris blades. The iris blades shown in front in the figure are denoted as "upper," and the iris blades shown partly hidden behind the front ones are denoted as "lower." Each iris blade is attached to the inner ring by a pivot assembly and to the outer ring by a roller/slider assembly. The upper and lower rings are co-centered and are kept in sliding contact. The iris is opened or closed by turning the outer ring around the center while holding the inner ring stationary. The mechanism is enclosed in a housing (not shown in the figure) that comprises an upper and a lower housing shell. The housing provides part of the sliding support for the outer ring and keeps the two rings aligned as described above. The aforementioned pivot assemblies at the inner ring also serve as spacers for the housing. The lower housing shell contains part of the lower sliding surface and features for mounting the overall mechanism and housing assembly. The upper housing shell contains part of the upper sliding surface.
Early outcomes with a single-sided access endovascular stent.
Hofmann, Michael; Pecoraro, Felice; Planer, David; Pfammatter, Thomas; Puippe, Gilbert; Bettex, Dominique; Veith, Frank J; Lachat, Mario; Chaykovska, Lyubov
2018-03-27
The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
18. Detail view of central pivot pier, drive gear rack, ...
18. Detail view of central pivot pier, drive gear rack, and stabilizing wheel, looking southwest - India Point Railroad Bridge, Spanning Seekonk River between Providence & East Providence, Providence, Providence County, RI
Steam separator latch assembly
Challberg, Roy C.; Kobsa, Irvin R.
1994-01-01
A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof.
Steam separator latch assembly
Challberg, R.C.; Kobsa, I.R.
1994-02-01
A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof. 12 figures.
Reliability of the anterior drawer test, the pivot shift test, and the Lachman test.
Kim, S J; Kim, H K
1995-08-01
In 147 patients with arthroscopically proved chronic injuries of the anterior cruciate ligament, the anterior drawer test, the Lachman test, and the pivot shift test were done before operation under general or spinal anesthesia. Results of the anterior drawer test were positive in 79.6% of the patients, in 98.6% patients having the Lachman test, and in 89.8% of patients having the pivot shift test. In 19 cases (12.9%), arthroscopic examination showed reattachment of the proximally torn end of the anterior cruciate ligament to the posterior cruciate ligament. In these cases, results of the anterior drawer test were positive in 13 patients (68.4%), in 17 (89.5%) patients having the Lachman test, and in 12 patients (63.2%) having the pivot shift test. In 15 cases with a false negative pivot shift test, arthroscopy showed blockage of anterior subluxation of the lateral tibial condyle by a partially functioning portion of the anterior cruciate ligament, which was reattached to the posterior cruciate ligament in 7 cases. In 2 cases with a false negative Lachman test, there was firm reattachment of the torn end of the anterior cruciate ligament to the proximal portion of the posterior cruciate ligament combined with a bucket handle tear of the medial meniscus. The Lachman test was most sensitive in diagnosing chronic injuries of the anterior cruciate ligament. The pivot shift test was also sensitive but was influenced by many factors.
Data-driven sensor placement from coherent fluid structures
NASA Astrophysics Data System (ADS)
Manohar, Krithika; Kaiser, Eurika; Brunton, Bingni W.; Kutz, J. Nathan; Brunton, Steven L.
2017-11-01
Optimal sensor placement is a central challenge in the prediction, estimation and control of fluid flows. We reinterpret sensor placement as optimizing discrete samples of coherent fluid structures for full state reconstruction. This permits a drastic reduction in the number of sensors required for faithful reconstruction, since complex fluid interactions can often be described by a small number of coherent structures. Our work optimizes point sensors using the pivoted matrix QR factorization to sample coherent structures directly computed from flow data. We apply this sampling technique in conjunction with various data-driven modal identification methods, including the proper orthogonal decomposition (POD) and dynamic mode decomposition (DMD). In contrast to POD-based sensors, DMD demonstrably enables the optimization of sensors for prediction in systems exhibiting multiple scales of dynamics. Finally, reconstruction accuracy from pivot sensors is shown to be competitive with sensors obtained using traditional computationally prohibitive optimization methods.
Lifting system and apparatus for constructing wind turbine towers
Livingston, Tracy; Schrader, Terry; Goldhardt, James; Lott, James
2011-02-01
The disclosed invention is utilized for mounting a wind turbine and blade assembly on the upper end of a wind turbine tower. The invention generally includes a frame or truss that is pivotally secured to the top bay assembly of the tower. A transverse beam is connected to the frame or truss and extends fore of the tower when the frame or truss is in a first position and generally above the tower when in a second position. When in the first position, a wind turbine or blade assembly can be hoisted to the top of the tower. The wind turbine or blade assembly is then moved into position for mounting to the tower as the frame or truss is pivoted to a second position. When the turbine and blade assembly are secured to the tower, the frame or truss is disconnected from the tower and lowered to the ground.
New graphic AUC-based method to estimate overall survival benefit: pomalidomide reanalysis.
Fenix-Caballero, S; Diaz-Navarro, J; Prieto-Callejero, B; Rios-Sanchez, E; Alegre-del Rey, E J; Borrero-Rubio, J M
2016-02-01
Difference in median survival is an erratic measure and sometimes does not provide a good assessment of survival benefit. The aim of this study was to reanalyse the overall survival benefit of pomalidomide from pivotal clinical trial using a new area under curve (AUC)-based method. In the pivotal trial, pomalidomide plus low-dose dexamethasone showed a significant survival benefit over high-dose dexamethasone, with a difference between medians of 4.6 months. The new AUC method applied to the survival curves, obtained an overall survival benefit of 2.6 months for the pomalidomide treatment. This average difference in OS was calculated for the 61.5% of patients for whom the time to event is reliable enough. This 2-month differential would have major clinical and pharmacoeconomic implications, on both cost-effectiveness studies and on the willingness of the healthcare systems to pay for this treatment. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Sheheitli, H.; Touma, J. R.
2018-06-01
We investigate the dynamics of a spinning top driven by a turntable that rotates with a given angular speed Ω. The pivot point of the top is at a fixed distance from the center of the turntable. We show that such a setup leads to resonance where the spinning top is locked in a state of relative equilibrium: precessing with an angular speed equal to that of the turntable while maintaining a constant nutation angle. Bifurcation diagrams are presented to depict how the stability of these relative equilibria, along with the corresponding value of the nutation angle, depends on the two parameters: the initial spin angular momentum and Ω. We discuss the classical spinning top, that is, the Ω = 0 case, and address the relation of the "sleeping top" state to the aforementioned relative equilibria. We also relate the dynamics to that of a spherical pendulum on a rotary arm and show that the latter can be viewed as a special case of the system at hand. Finally, we illustrate how the relative equilibria can be exploited for the attitude control of the top through resonance capture while slowly varying the turnable angular speed, Ω.
Neural decoding with kernel-based metric learning.
Brockmeier, Austin J; Choi, John S; Kriminger, Evan G; Francis, Joseph T; Principe, Jose C
2014-06-01
In studies of the nervous system, the choice of metric for the neural responses is a pivotal assumption. For instance, a well-suited distance metric enables us to gauge the similarity of neural responses to various stimuli and assess the variability of responses to a repeated stimulus-exploratory steps in understanding how the stimuli are encoded neurally. Here we introduce an approach where the metric is tuned for a particular neural decoding task. Neural spike train metrics have been used to quantify the information content carried by the timing of action potentials. While a number of metrics for individual neurons exist, a method to optimally combine single-neuron metrics into multineuron, or population-based, metrics is lacking. We pose the problem of optimizing multineuron metrics and other metrics using centered alignment, a kernel-based dependence measure. The approach is demonstrated on invasively recorded neural data consisting of both spike trains and local field potentials. The experimental paradigm consists of decoding the location of tactile stimulation on the forepaws of anesthetized rats. We show that the optimized metrics highlight the distinguishing dimensions of the neural response, significantly increase the decoding accuracy, and improve nonlinear dimensionality reduction methods for exploratory neural analysis.
Gaber, Lillian W
2007-08-01
Pancreas transplantation has become a therapeutic option for patients with type 1 diabetes mellitus who are in end-stage renal failure. It also is indicated for a subset of nonuremic, insulin-dependent diabetics who experience extreme difficulties in maintaining proper glucose homeostasis by insulin therapy that compromises their productivity and safety. To provide a review of the literature and expert experiences for understanding the histologic findings in pancreas transplantation. The published literature between 1990 and 2005 was reviewed for this report. Additionally, personal files of the author were used, along with biopsy slides that were used for figures. Pancreas transplantation reestablishes the physiologic state of insulin secretion, and pancreas transplant recipients are able to maintain a state of long-term euglycemia and are less likely to be exposed to hyperglycemia and its systemic complications. Key to the success of transplantation is the scrupulous management and close monitoring of the pancreas transplant recipients. To that end, histologic evaluation of pancreas allografts assumed a pivotal role in management of pancreas allograft dysfunction episodes, and in some centers surveillance biopsies are used to monitor immunologically high-risk situations.
The retention of health human resources in primary healthcare centers in Lebanon: a national survey.
Alameddine, Mohamad; Saleh, Shadi; El-Jardali, Fadi; Dimassi, Hani; Mourad, Yara
2012-11-22
Critical shortages of health human resources (HHR), associated with high turnover rates, have been a concern in many countries around the globe. Of particular interest is the effect of such a trend on the primary healthcare (PHC) sector; considered a cornerstone in any effective healthcare system. This study is a rare attempt to investigate PHC HHR work characteristics, level of burnout and likelihood to quit as well as the factors significantly associated with staff retention at PHC centers in Lebanon. A cross-sectional design was utilized to survey all health providers at 81 PHC centers dispersed in all districts of Lebanon. The questionnaire consisted of four sections: socio-demographic/ professional background, organizational/institutional characteristics, likelihood to quit and level of professional burnout (using the Maslach-Burnout Inventory). A total of 755 providers completed the questionnaire (60.5% response rate). Bivariate analyses and multinomial logistic regression were used to determine factors associated with likelihood to quit. Two out of five respondents indicated likelihood to quit their jobs within the next 1-3 years and an additional 13.4% were not sure about quitting. The top three reasons behind likelihood to quit were poor salary (54.4%), better job opportunities outside the country (35.1%) and lack of professional development (33.7%). A U-shaped relationship was observed between age and likelihood to quit. Regression analysis revealed that high levels of burnout, lower level of education and low tenure were all associated with increased likelihood to quit. The study findings reflect an unstable workforce and are not conducive to supporting an expanded role for PHC in the Lebanese healthcare system. While strategies aiming at improving staff retention would be important to develop and implement for all PHC HHR; targeted retention initiatives should focus on the young-new recruits and allied health professionals. Particular attention should be dedicated to enhancing providers' role satisfaction and sense of job security. Such initiatives are of pivotal importance to stabilize the workforce and ensure its longevity.
The retention of health human resources in primary healthcare centers in Lebanon: a national survey
2012-01-01
Background Critical shortages of health human resources (HHR), associated with high turnover rates, have been a concern in many countries around the globe. Of particular interest is the effect of such a trend on the primary healthcare (PHC) sector; considered a cornerstone in any effective healthcare system. This study is a rare attempt to investigate PHC HHR work characteristics, level of burnout and likelihood to quit as well as the factors significantly associated with staff retention at PHC centers in Lebanon. Methods A cross-sectional design was utilized to survey all health providers at 81 PHC centers dispersed in all districts of Lebanon. The questionnaire consisted of four sections: socio-demographic/ professional background, organizational/institutional characteristics, likelihood to quit and level of professional burnout (using the Maslach-Burnout Inventory). A total of 755 providers completed the questionnaire (60.5% response rate). Bivariate analyses and multinomial logistic regression were used to determine factors associated with likelihood to quit. Results Two out of five respondents indicated likelihood to quit their jobs within the next 1–3 years and an additional 13.4% were not sure about quitting. The top three reasons behind likelihood to quit were poor salary (54.4%), better job opportunities outside the country (35.1%) and lack of professional development (33.7%). A U-shaped relationship was observed between age and likelihood to quit. Regression analysis revealed that high levels of burnout, lower level of education and low tenure were all associated with increased likelihood to quit. Conclusions The study findings reflect an unstable workforce and are not conducive to supporting an expanded role for PHC in the Lebanese healthcare system. While strategies aiming at improving staff retention would be important to develop and implement for all PHC HHR; targeted retention initiatives should focus on the young-new recruits and allied health professionals. Particular attention should be dedicated to enhancing providers’ role satisfaction and sense of job security. Such initiatives are of pivotal importance to stabilize the workforce and ensure its longevity. PMID:23173905
Fischer, William H.
1984-01-01
A gas-insulated transmission line includes a corrugated outer conductor, an inner conductor disposed within and insulated from the outer conductor by means of support insulators and an insulating gas, and a non-binding transport device for supporting and permitting movement of the inner conductor/insulating support assembly axially along the corrugated outer conductor without radial displacement and for moving without binding along corrugations of any slope less than vertical. The transport device includes two movable contacts, such as skids or rollers, supported on a common pivot lever, the pivot lever being rotatably disposed about a pivot lever axis, which pivot lever axis is in turn disposed on the periphery of a support insulator or particle trap if one is used. The movable contacts are separated axially a distance equal to the axial distance between the peaks and valleys of the corrugations of the outer conductor and separated radially a distance equal to the radial distance between the peaks and valleys of the corrugations of the outer conductor. The transport device has the pivot lever axis disposed parallel to the motion of travel of the inner conductor/insulating support assembly.
Plant responses, climate pivot points, and trade-offs in water-limited ecosystems
NASA Astrophysics Data System (ADS)
Munson, S. M.; Bunting, E.
2017-12-01
Ecosystem transitions and thresholds are conceptually well-defined and have become a framework to address vegetation response to climate change and land-use intensification, yet there are few approaches to define the environmental conditions which can lead to them. We demonstrate a novel climate pivot point approach using long-term monitoring data from a broad network of permanent plots, satellite imagery, and experimental treatments across the southwestern U.S. The climate pivot point identifies conditions that lead to decreased plant performance and serves as an early warning sign of increased vulnerability of crossing a threshold into an altered ecosystem state. Plant responses and climate pivot points aligned with the lifespan and structural characteristics of species, were modified by soil and landscape attributes of a site, and had non-linear dynamics in some cases. Species with strong increases in abundance when water was available were most susceptible to losses during water shortages, reinforcing plant energetic and physiological tradeoffs. Future research to uncover the heterogeneity of plant responses and climate pivot points at multiple scales can lead to greater understanding of shifts in ecosystem productivity and vulnerability to climate change.
Li, Wan; Chen, Lina; Li, Xia; Jia, Xu; Feng, Chenchen; Zhang, Liangcai; He, Weiming; Lv, Junjie; He, Yuehan; Li, Weiguo; Qu, Xiaoli; Zhou, Yanyan; Shi, Yuchen
2013-12-01
Network motifs in central positions are considered to not only have more in-coming and out-going connections but are also localized in an area where more paths reach the networks. These central motifs have been extensively investigated to determine their consistent functions or associations with specific function categories. However, their functional potentials in the maintenance of cross-talk between different functional communities are unclear. In this paper, we constructed an integrated human signaling network from the Pathway Interaction Database. We identified 39 essential cancer-related motifs in central roles, which we called cancer-related marketing centrality motifs, using combined centrality indices on the system level. Our results demonstrated that these cancer-related marketing centrality motifs were pivotal units in the signaling network, and could mediate cross-talk between 61 biological pathways (25 could be mediated by one motif on average), most of which were cancer-related pathways. Further analysis showed that molecules of most marketing centrality motifs were in the same or adjacent subcellular localizations, such as the motif containing PI3K, PDK1 and AKT1 in the plasma membrane, to mediate signal transduction between 32 cancer-related pathways. Finally, we analyzed the pivotal roles of cancer genes in these marketing centrality motifs in the pathogenesis of cancers, and found that non-cancer genes were potential cancer-related genes.
Gao, Kun; Chen, Fanjun; Yuan, Lixing; Mi, Guohua
2013-01-01
The inhibitory effect of ammonium on primary root growth has been well documented; however the underlying physiological and molecular mechanisms are still controversial. To avoid ammonium toxicity to shoot growth, we used a vertical two-layer split plate system, in which the upper layer contained nitrate and the lower layer contained ammonium. In this way, nitrogen status was maintained and only the apical part of the root system was exposed to ammonium. Using a kinematic approach, we show here that 1 mM ammonium reduces primary root growth, decreasing both elemental expansion and cell production. Ammonium inhibits the length of elongation zone and the maximum elemental expansion rate. Ammonium also decreases the apparent length of the meristem as well as the number of dividing cells without affecting cell division rate. Moreover, ammonium reduces the number of root cap cells but appears to affect neither the status of root stem cell niche nor the distal auxin maximum at the quiescent center. Ammonium also inhibits root gravitropism and concomitantly down-regulates the expression of two pivotal auxin transporters, AUX1 and PIN2. Insofar as ammonium inhibits root growth rate in AUX1 and PIN2 loss-of-function mutants almost as strongly as in wild type, we conclude that ammonium inhibits root growth and gravitropism by largely distinct pathways. PMID:23577185
Ecological Consciousness in Ontario Elementary Schools: The Truant Curriculum and the Consequences
ERIC Educational Resources Information Center
Puk, T.; Makin, Darrell
2006-01-01
Global ecological degradation is currently causing widespread suffering and this is expected to worsen unless we change our global behaviors. Wilson (2002) has suggested that the consequences of ecological degradation are a threat to all life on earth. Woodbridge (2004) asserts that human pressures on natural systems will reach pivotal status by…
1994: New Academic Profession for a New South Africa?
ERIC Educational Resources Information Center
Wolhuter, C. C.
2015-01-01
Since 1994, the eyes of the world have been on South Africa, observing with interest the societal reconstruction project, upon which the country had embarked. In this project, higher education is both the terrain and the perceived instrument of change. In this higher education system and its mission, the academic profession is pivotal--especially,…
USDA-ARS?s Scientific Manuscript database
Microbial symbionts play pivotal roles in the ecology and physiology of insects feeding in woody plants. Both eukaryotic and bacterial members occur in these systems where they facilitate digestive and nutrition provisioning. The larval gut of the Asian longhorned beetle (Anoplophora glabripennis) i...
Casting a Statewide Strategic Performance Net: Interlaced Data and Responsive Supports
ERIC Educational Resources Information Center
Layland, Allison; Redding, Sam
2017-01-01
The pivot point for educational change is now firmly placed with the district, rebalancing the position of the state and the school relative to the local education agency (LEA). The state education agency (SEA) has been shifting its emphasis for decades, from a compliance-focused authority to a change agent equipped with systems, processes,…
Creating an Optimal Language Learning Environment: A Focus on Family and Culture
ERIC Educational Resources Information Center
Cheng, Li-Rong Lilly
2009-01-01
Understanding the family systems and structures of our diverse populations is one of the most important tasks of professionals in education. Children learn from their family, school, and community. They learn from their experiences by observing, talking, and interacting with their environment. Parents play a pivotal role in the education of their…
Maximizing the Impact: The Pivotal Role of Technology in a 21st Century Education System
ERIC Educational Resources Information Center
Vockley, Martha
2007-01-01
All students need a more robust education--and a refreshingly different kind of education--than most are getting today. The vision of learning individuals embrace focuses on teaching students to become critical thinkers, problem solvers and innovators; effective communicators and collaborators; and self-directed learners. This vision responds to…
Visualization in Mechanics: The Dynamics of an Unbalanced Roller
ERIC Educational Resources Information Center
Cumber, Peter S.
2017-01-01
It is well known that mechanical engineering students often find mechanics a difficult area to grasp. This article describes a system of equations describing the motion of a balanced and an unbalanced roller constrained by a pivot arm. A wide range of dynamics can be simulated with the model. The equations of motion are embedded in a graphical…
The Damaged Object: A "Strange Attractor" in the Dynamical System of the Mind
ERIC Educational Resources Information Center
Shulman, Graham
2010-01-01
This article discusses the impact of the damaged object on the development and functioning of psychic life with particular reference to the sense of reality. The damaged object is of pivotal significance in Klein's and Winnicott's models of psychic development and experience in early infancy. A key dimension of the development and functioning of…
The Effect of Feedback on Instructional Behaviours of Pre-Service Teacher Education
ERIC Educational Resources Information Center
Gürkan, Serkan
2018-01-01
Teacher training programs have a pivotal role in sophisticated Turkish education system. In order to reach high standards in teacher training, trainers should encourage and supervise pre-service teachers to use effective teaching skills and strategies. To ensure that providing feedback is regarded to be a widely accepted way for maximizing the use…
2008-02-14
g. Material. 5.1.7 Wheel Geometry. a. Camber angle. b. Caster angle. c. Pivot angle. d. Static toe-in. e. Turning angles...the vehicle characteristics to be obtained during testing of wheeled and tracked vehicles and their components. Physical characterization of test...frontal area Characteristic data sheet Power train Suspention Wheel geometry Vehicle clearance angles Armament Gun control systems 16. SECURITY
ERIC Educational Resources Information Center
Weeks, Ann Carlson; DiScala, Jeffrey; Barlow, Diane L.; Massey, Sheri A.; Kodama, Christie; Hall, Rosemary; Jarrell, Kelsey; Jacobs, Leah; Moses, Alexandra; Follman, Rebecca
2017-01-01
The school district library supervisor plays a pivotal role in supporting, advising, and providing professional development to building-level librarians; advocating for the program; providing leadership; and representing school library programs to stakeholders in the school system and the larger community. To gain a better understanding of…
Nitrogen and water management strategies to reduce nitrate leaching under irrigated maize
NASA Astrophysics Data System (ADS)
Schepers, J. S.; Varvel, G. E.; Watts, D. G.
1995-12-01
Cropping systems that fail to integrate nitrogen (N) water management are frequently associated with elevated concentrations of nitrate-N in soil and groundwater. Examples of poorly integrated management practices are abundant, especially where irrigation is used to minimize the effects of drought and N fertilizer is inexpensive. Two maize fields under improved water and N management practices at the Nebraska Management Systems Evaluation Area (MSEA) project were compared with an adjacent field under conventional furrow irrigation that followed management guidelines mandated by the local Natural Resources District. Surge-flow furrow irrigation with laser grading and a runoff-water recovery system reduced water application by 45-69% compared to conventional furrow irrigation over the three years of this study. Center-pivot sprinkler irrigation reduced water application by 60-72% compared to conventional furrow irrigation. Uniformity of water application was improved with the surge-flow and sprinkler irrigation systems, which made it reasonable to consider adding fertilizer N in the water (fertigation) to meet crop needs. The spoon-feeding strategy, based on chlorophyll meter readings to schedule fertigation, saved 168 kg ha t1¯ N the first year and 105 kg ha -1 N the second year without reducing yields. Near total reliance of fertigation to meet crop N needs resulted in a 15% yield reduction the second year because spatial variability in soil N status made it difficult to collect representative chlorophyll meter data. Plot studies showed chlorophyll meter readings and yields were consistently higher for maize following soybean than where maize was grown in monoculture.
The Pivot to Asia: Can It Serve as the Foundation for American Grand Strategy in the 21st Century
in which the Obama Administration cannot make a definitive choice in favor of one of these schools of thought, it has opted for a policy of hedging...also discusses the problems that the Obama Administration has been forced to confront in other placese.g., Ukraine, Libya, Syria, etc.that have...complicated its efforts to keep its focus on the pivot strategy in the IAP region. He concludes with some lessons for strategists, derived from the Obama teams experience with the pivot.
Development and Present Situation Analysis of Power Transformer State Maintenance
NASA Astrophysics Data System (ADS)
Lv, Sen; Li, Biao; Li, Huan
2018-02-01
The pivotal status of power transformer in the power system is one of the most important equipment. The safety and reliability of its operation is directly related to the safety and stability of power system. Based on the analysis of the present situation of power transformer state maintenance in home and abroad. The paper points out the deficiency of the current method and provides a theoretical basis for further research, which has a certain guiding significance.
2010-09-01
matrix is used in many methods, like Jacobi or Gauss Seidel , for solving linear systems. Also, no partial pivoting is necessary for a strictly column...problems that arise during the procedure, which in general, converges to the solving of a linear system. The most common issue with the solution is the... iterative procedure to find an appropriate subset of parameters that produce an optimal solution commonly known as forward selection. Then, the
A Flexible CUDA LU-based Solver for Small, Batched Linear Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumeo, Antonino; Gawande, Nitin A.; Villa, Oreste
This chapter presents the implementation of a batched CUDA solver based on LU factorization for small linear systems. This solver may be used in applications such as reactive flow transport models, which apply the Newton-Raphson technique to linearize and iteratively solve the sets of non linear equations that represent the reactions for ten of thousands to millions of physical locations. The implementation exploits somewhat counterintuitive GPGPU programming techniques: it assigns the solution of a matrix (representing a system) to a single CUDA thread, does not exploit shared memory and employs dynamic memory allocation on the GPUs. These techniques enable ourmore » implementation to simultaneously solve sets of systems with over 100 equations and to employ LU decomposition with complete pivoting, providing the higher numerical accuracy required by certain applications. Other currently available solutions for batched linear solvers are limited by size and only support partial pivoting, although they may result faster in certain conditions. We discuss the code of our implementation and present a comparison with the other implementations, discussing the various tradeoffs in terms of performance and flexibility. This work will enable developers that need batched linear solvers to choose whichever implementation is more appropriate to the features and the requirements of their applications, and even to implement dynamic switching approaches that can choose the best implementation depending on the input data.« less
NASA Technical Reports Server (NTRS)
Wilson, Andrew (Inventor); Punnoose, Andrew (Inventor); Strausser, Katherine (Inventor); Parikh, Neil (Inventor)
2011-01-01
A mobile robotic unit features a main body, a plurality of legs for supporting the main body on and moving the main body in forward and reverse directions about a base surface, and a drive assembly. According to an exemplary embodiment each leg includes a respective pivotal hip joint, a pivotal knee joint, and a wheeled foot adapted to roll along the base surface. Also according to an exemplary embodiments the drive assembly includes a motor operatively associated with the hip and knee joints and the wheeled foot for independently driving pivotal movement of the hip joint and the knee joint and rolling motion of the wheeled foot. The hip joint may include a ball-and-socket-type joint interconnecting top portion of the leg to the main body, such that the hip joint is adapted to pivot said leg in a direction transverse to a forward-and-reverse direction.
Dual resolution, vacuum compatible optical mount
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halpin, John Michael
2011-10-04
An optical mount for an optical element includes a mounting plate, a lever arm pivot coupled to mounting plate, and an adjustment plate. The optical mount also includes a flexure pivot mechanically coupling the adjustment plate to the mounting plate and a lever arm. The optical mount further includes a first adjustment device extending from the adjustment plate to make contact with the lever arm at a first contact point. A projection of a line from the first contact point to a pivot point, measured along the lever arm, is a first predetermined distance. The optical mount additionally includes amore » second adjustment device extending from the adjustment plate to make contact with the lever arm at a second contact point. A projection of a line from the second contact point to the pivot point, measured along the lever arm, is a second predetermined distance greater than the first predetermined distance.« less
NASA Astrophysics Data System (ADS)
Liou-Mark, J.; Blake, R.
2014-12-01
With community college and two-year program students playing pivotal roles in advancing the nation's STEM agenda now and throughout the remainder of this young millennia, it is incumbent on educators to devise innovative and sustainable STEM initiatives to attract, retain, graduate, and elevate these students to four-year programs and beyond. Involving these students in comprehensive, holistic research experiences is one approach that has paid tremendous dividends. The New York City College of Technology (City Tech) was recently awarded a National Science Foundation Research Experiences for Undergraduates (REU) supplemental grant to integrate a community college/two-year program component into its existing REU program. The program created an inviting and supportive community of scholars for these students, nurtured them through strong, dynamic mentoring, provided them with the support structures needed for successful scholarship, and challenged them to attain the same research prominence as their Bachelor degree program companions. Along with their colleagues, the community college/two-year program students were given an opportunity to conduct intensive satellite and ground-based remote sensing research at the National Oceanic and Atmospheric Administration Cooperative Remote Sensing Science and Technology Center (NOAA-CREST) at City College and its CREST Institute Center for Remote Sensing and Earth System Science (ReSESS) at City Tech. This presentation highlights the challenges, the rewards, and the lessons learned from this necessary and timely experiment. Preliminary results indicate that this paradigm for geoscience inclusion and high expectation has been remarkably successful. (The program is supported by NSF REU grant #1062934.)
Modified rib pivot lateral thoracotomy: a case series.
Appelgrein, C; Hosgood, G
2018-01-01
To describe a modified rib pivot thoracotomy and its clinical application in client-owned dogs and cats. Case series of 24 dogs and 1 cat requiring a thoracotomy. A lateral thoracic incision over the required thoracic segment was made. The latissimus dorsi muscle was reflected dorsally. The predetermined rib was identified and the periosteum overlying the rib was elevated circumferentially, avoiding the intercostal neurovascular structures. Holes were pre-placed above and below the proposed osteotomy site. The rib was osteotomised and pivoted cranially. The pleura was incised and the required intrathoracic procedure was then performed. The thoracic cavity was closed by pre-placement of a suture through the pre-placed holes within the osteotomised rib. The pleura and intercostal musculature were closed, avoiding the intercostal neurovascular structures. The rib was re-apposed and the lateral approach was closed. The cases included were reviewed for both the rib pivoted as per the procedure required and postoperative complications. The study group comprised 8 Staffordshire Bull Terriers, 2 Poodles, 2 German Shepherd Dogs, 1 each of Basset Hound, Rhodesian Ridgeback, Golden Retriever, Australian Shepherd, Vizsla, Bull Mastiff, Schnauzer, Jack Russell Terrier, Bulldog, Deerhound, Labrador Retriever and Australian Terrier, and 1 cat. A modified rib pivot thoracotomy was performed for lung lobectomy (n = 11), oesophagectomy (7), subtotal pericardectomy (5), patent ductus arteriosus ligation (1) and thoracic duct ligation (1). Follow-up ranged from 2 to 40 weeks postoperatively. Postoperative complications included seroma formation in two dogs. A modified rib pivot thoracotomy should be considered as an alternative lateral thoracic approach with good exposure, minimal complications and low morbidity. © 2018 Australian Veterinary Association.
Support system design of the sub-mirror cell of the LAMOST Schmidt plate
NASA Astrophysics Data System (ADS)
Yang, Dehua; Jiang, Fanghua
2006-06-01
The reflecting Schmidt plate of the Large sky Area Multi-Object Spectroscopic Telescope (LAMOST) is composed of 24 hexagonal segments, each of which is 1100 mm from corner to corner and 25 mm in thickness. Both segmented mirror active optics and deformable mirror active optics are involved in the Schmidt plate so as to compensate for optical aberration and structural deformation. A prototype of the segment support system with dummy aluminum mirror had been setup and tested during 2003 to 2004, afterwards, based on the evaluation of test, the whole support system was updated to a backlash-free and light-weighted design. For the segmented mirror active optics, the segment mirror support system is to fulfill motions of tip, tilt and piston with three linear positioning actuators. Instead of self-alignment bearing adopted in the early prototype, a centering diaphragm is employed to realize a backlash-free pintle. And a lever with reduction of 10:1 is introduced to each of the three positioning actuator mechanisms, respectively, to obtain greater load capacity and further finer output displacement, as hence releases requirement and cost of the actuators. For better performance, high strength steel blades are used in tension state for pivots of the levers preloaded with longitudinal springs. To gap the mirror segments with respect to each other for making proper space for edge sensors, three adjustable fixtures are implemented for each segment mirror module to do translation and pistion on three conrresponding nodes on the top layer of the gross mirror cell truss before being anchored once and forever. In addition, safety measurements as well as anti-rotation mechanism have been taken into consideration throughout the design and development process. This paper describes the mechanical design and related analysis of the segment mirror support system in detail.
Torque Compensator for Mirror Mountings
NASA Technical Reports Server (NTRS)
Howe, S. D.
1983-01-01
Device nulls flexural distributions of pivotal torques. Magnetic compensator for flexing pivot torque consists of opposing fixed and movable magnet bars. Magnetic torque varies nonlinearly as function of angle of tilt of movable bar. Positions of fixed magnets changed to improve magnetic torque linearity.
Compound floating pivot micromechanisms
Garcia, Ernest J.
2001-04-24
A new class of tilting micromechanical mechanisms have been developed. These new mechanisms use compound floating pivot structures to attain far greater tilt angles than are practical using other micromechanical techniques. The new mechanisms are also capable of bi-directional tilt about multiple axes.
Investigation of delayed cracking in pivot steel box girders.
DOT National Transportation Integrated Search
1997-01-01
This report describes the results of an investigation to find the cause of the delayed cracking in the welds of the fracturecritical steel pivot box girders fabricated for the George P. Coleman Bridge. Through the use of different nondestructive meth...
New fundamental parameters for attitude representation
NASA Astrophysics Data System (ADS)
Patera, Russell P.
2017-08-01
A new attitude parameter set is developed to clarify the geometry of combining finite rotations in a rotational sequence and in combining infinitesimal angular increments generated by angular rate. The resulting parameter set of six Pivot Parameters represents a rotation as a great circle arc on a unit sphere that can be located at any clocking location in the rotation plane. Two rotations are combined by linking their arcs at either of the two intersection points of the respective rotation planes. In a similar fashion, linking rotational increments produced by angular rate is used to derive the associated kinematical equations, which are linear and have no singularities. Included in this paper is the derivation of twelve Pivot Parameter elements that represent all twelve Euler Angle sequences, which enables efficient conversions between Pivot Parameters and any Euler Angle sequence. Applications of this new parameter set include the derivation of quaternions and the quaternion composition rule, as well as, the derivation of the analytical solution to time dependent coning motion. The relationships between Pivot Parameters and traditional parameter sets are included in this work. Pivot Parameters are well suited for a variety of aerospace applications due to their effective composition rule, singularity free kinematic equations, efficient conversion to and from Euler Angle sequences and clarity of their geometrical foundation.
Kim, Jae-Woong; Kwon, Moon-Seok; Yenuga, Sree Sushma; Kwon, Young-Hoooo
2010-06-01
The study purpose was to investigate the effects of target distance on pivot hip, trunk, pelvis, and kicking leg movements in Taekwondo roundhouse kick. Twelve male black-belt holders executed roundhouse kicks for three target distances (Normal, Short, and Long). Linear displacements of the pivot hip and orientation angles of the pelvis, trunk, right thigh, and right shank were obtained through a three-dimensional video motion analysis. Select displacements, distances, peak orientation angles, and angle ranges were compared among the conditions using one-way repeated measure ANOVA (p < 0.05). Several orientation angle variables (posterior tilt range, peak right-tilted position, peak right-rotated position, peak left-rotated position, and left rotation range of the pelvis; peak hyperextended position and peak right-flexed position of the trunk; peak flexed position, flexion range and peak internal-rotated position of the hip) as well as the linear displacements of the pivot hip and the reach significantly changed in response to different target distances. It was concluded that the adjustment to different target distances was mainly accomplished through the pivot hip displacements, hip flexion, and pelvis left rotation. Target distance mainly affected the reach control function of the pelvis and the linear balance function of the trunk.
Walter Reed Army Medical Center's mental health response to the Pentagon attack.
Cozza, Stephen J; Huleatt, William J; James, Larry C
2002-09-01
The September 11 terrorist attack on the Pentagon captured the attention and concern of America as well as the world. Given the extent of devastation, and the number of deaths at the Pentagon, it was believed that the uniformed mental health services would serve a pivotal role in the recovery and relief efforts. This article provides a synopsis of the complex and multidisciplinary mental health services provided by Walter Reed Army Medical Center in the wake of the September 11 attack on the Pentagon. This article offers an overview of the functions and roles of mental health team members, describes a constellation of services rendered, and describes how missions differed inside and outside of the Pentagon. Additionally, the authors provide the reader with how services were provided at the Family Assistance Center to family members of those killed during the attack. Liaison with civilian medical, mental health, and relief agencies and facilities will be discussed as well. The mental health response was an intensive and complicated experience and has yielded many lesson learned. To this end, the authors will provide the reader with an understanding of how the lessons learned during this mission may assist mental health commanders and leaders in planning and responding to similar deployments in the future.
ERIC Educational Resources Information Center
Hancock, Dawson R.; Muller, Ulrich
2009-01-01
In the United States and Germany, effective school leadership is pivotal to a school's success. Yet in each country, attracting and retaining qualified school leaders is a formidable challenge. This study compares the influence of possible motivators and inhibitors that impact teachers' decisions to become principals in the two countries. Survey…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
Basham, James D.; Smith, Sean J.; Greer, Diana L.; Marino, Matthew T.
2013-01-01
This article examines the complex array of variables and implementation models that must be accounted for during the pivot from a purely brick-and-mortar educational system to one that makes use of both virtual and blended environments. The authors call for enhanced emphasis on instructional goals and design principles, rather than available…
ERIC Educational Resources Information Center
Rosenwald, Mitchell; Bronstein, Laura
2008-01-01
Foster parents play a pivotal role in the child welfare system. A study that employed focus groups with foster parents was conducted at a private foster care agency with the initial purpose of understanding the characteristics of foster children that foster parents both preferred and not preferred. In the qualitative research tradition, their…
The European Research Elite: A Cross-National Study of Highly Productive Academics in 11 Countries
ERIC Educational Resources Information Center
Kwiek, Marek
2016-01-01
In this paper, we focus on a rare scholarly theme of highly productive academics, statistically confirming their pivotal role in knowledge production across 11 systems studied. The upper 10% of highly productive academics in 11 European countries studied (N = 17,211) provide on average almost half of all academic knowledge production. In contrast…
An automated data collection system for a Charpy impact tester
NASA Technical Reports Server (NTRS)
Weigman, Bernard J.; Spiegel, F. Xavier
1993-01-01
A method for automated data collection has been developed for a Charpy impact tester. A potentiometer is connected to the pivot point of the hammer and measures the angular displacement of the hammer. This data is collected with a computer and, through appropriate software, accurately records the energy absorbed by the specimen. The device can be easily calibrated with minimal effort.
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
Perceptions of Peer to Peer HIV/AIDS Education: A Social Work Perspective
ERIC Educational Resources Information Center
Sweifach, Jay; LaPorte, Heidi Heft
2006-01-01
Although advances in HIV/AIDS treatment and prevention have led to improvements in health and well-being, HIV/AIDS continues to be a global health concern, especially for adolescents and young adults. The school system, with its access to vast numbers of youth, has and continues to be the most pivotal player in prevention. This article reports on…
ERIC Educational Resources Information Center
Kramarczuk Voulgarides, Catherine; Fergus, Edward; King Thorius, Kathleen A.
2017-01-01
In the review, we examine what is known about disproportionality with the intention of informing the direction of policy and practice remedies. We outline the definition, contours, and characteristics of disproportionality and examine some of the prevailing explanations as to why the issue persists. We then pivot the review to consider how policy,…
ERIC Educational Resources Information Center
Walker, Ruth
2010-01-01
Five years after implementation, the Certificate IV in Training and Assessment (TAA40104, and hereafter also referred to as the Certificate IV) remains a pivotal qualification in the national vocational education and training (VET) system. Under the Australian Quality Training Framework (AQTF) it is the qualification required by both workplace…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
[Cell phone communication: hygienic characteristics, biological action, standardization (a review)].
Gudina, M V; Volkotrub, L P
2010-01-01
The paper considers the topical issues concerning the functioning of the cellular communication system. It provides the hygienic characteristics of its individual elements. The factors influencing the size of an electromagnetic field generated by mobile phones are stated. Research data on the impact of electromagnetic radiation from a mobile phone on users' health are reviewed. The pivots of present-day Russian hygienic rating regarding the permissible exposures to nonionizing electromagnetic energy generated by the elements of the cellular communication system are identified.
Method and apparatus for production of subsea hydrocarbon formations
Blandford, Joseph W.
1994-01-01
A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and export riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.
Method and apparatus for production of subsea hydrocarbon formations
Blandford, Joseph W.
1992-01-01
A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and expert riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.
Modal control theory and application to aircraft lateral handling qualities design
NASA Technical Reports Server (NTRS)
Srinathkumar, S.
1978-01-01
A multivariable synthesis procedure based on eigenvalue/eigenvector assignment is reviewed and is employed to develop a systematic design procedure to meet the lateral handling qualities design objectives of a fighter aircraft over a wide range of flight conditions. The closed loop modal characterization developed provides significant insight into the design process and plays a pivotal role in the synthesis of robust feedback systems. The simplicity of the synthesis algorithm yields an efficient computer aided interactive design tool for flight control system synthesis.
Timmerman, Dirk; Van Calster, Ben; Testa, Antonia; Savelli, Luca; Fischerova, Daniela; Froyman, Wouter; Wynants, Laure; Van Holsbeke, Caroline; Epstein, Elisabeth; Franchi, Dorella; Kaijser, Jeroen; Czekierdowski, Artur; Guerriero, Stefano; Fruscio, Robert; Leone, Francesco P G; Rossi, Alberto; Landolfo, Chiara; Vergote, Ignace; Bourne, Tom; Valentin, Lil
2016-04-01
Accurate methods to preoperatively characterize adnexal tumors are pivotal for optimal patient management. A recent metaanalysis concluded that the International Ovarian Tumor Analysis algorithms such as the Simple Rules are the best approaches to preoperatively classify adnexal masses as benign or malignant. We sought to develop and validate a model to predict the risk of malignancy in adnexal masses using the ultrasound features in the Simple Rules. This was an international cross-sectional cohort study involving 22 oncology centers, referral centers for ultrasonography, and general hospitals. We included consecutive patients with an adnexal tumor who underwent a standardized transvaginal ultrasound examination and were selected for surgery. Data on 5020 patients were recorded in 3 phases from 2002 through 2012. The 5 Simple Rules features indicative of a benign tumor (B-features) and the 5 features indicative of malignancy (M-features) are based on the presence of ascites, tumor morphology, and degree of vascularity at ultrasonography. Gold standard was the histopathologic diagnosis of the adnexal mass (pathologist blinded to ultrasound findings). Logistic regression analysis was used to estimate the risk of malignancy based on the 10 ultrasound features and type of center. The diagnostic performance was evaluated by area under the receiver operating characteristic curve, sensitivity, specificity, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), negative predictive value (NPV), and calibration curves. Data on 4848 patients were analyzed. The malignancy rate was 43% (1402/3263) in oncology centers and 17% (263/1585) in other centers. The area under the receiver operating characteristic curve on validation data was very similar in oncology centers (0.917; 95% confidence interval, 0.901-0.931) and other centers (0.916; 95% confidence interval, 0.873-0.945). Risk estimates showed good calibration. In all, 23% of patients in the validation data set had a very low estimated risk (<1%) and 48% had a high estimated risk (≥30%). For the 1% risk cutoff, sensitivity was 99.7%, specificity 33.7%, LR+ 1.5, LR- 0.010, PPV 44.8%, and NPV 98.9%. For the 30% risk cutoff, sensitivity was 89.0%, specificity 84.7%, LR+ 5.8, LR- 0.13, PPV 75.4%, and NPV 93.9%. Quantification of the risk of malignancy based on the Simple Rules has good diagnostic performance both in oncology centers and other centers. A simple classification based on these risk estimates may form the basis of a clinical management system. Patients with a high risk may benefit from surgery by a gynecological oncologist, while patients with a lower risk may be managed locally. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zimakov, L. G.; Raczka, J.; Barrientos, S. E.
2016-12-01
We will discuss and show the results obtained from an integrated SeismoGeodetic System, model SG160-09, installed in the Chile (Chilean National Network), Italy (University of Naples Network), and California. The SG160-09 provides the user high rate GNSS and accelerometer data, full epoch-by-epoch measurement integrity and the ability to create combined GNSS and accelerometer high-rate (200Hz) displacement time series in real-time. The SG160-09 combines seismic recording with GNSS geodetic measurement in a single compact, ruggedized case. The system includes a low-power, 220-channel GNSS receiver powered by the latest Trimble-precise Maxwell™6 technology and supports tracking GPS, GLONASS and Galileo signals. The receiver incorporates on-board GNSS point positioning using Real-Time Precise Point Positioning (PPP) technology with satellite clock and orbit corrections delivered over IP networks. The seismic recording includes an ANSS Class A, force balance accelerometer with the latest, low power, 24-bit A/D converter, producing high-resolution seismic data. The SG160-09 processor acquires and packetizes both seismic and geodetic data and transmits it to the central station using an advanced, error-correction protocol providing data integrity between the field and the processing center. The SG160-09 has been installed in three seismic stations in different geographic locations with different Trimble global reference stations coverage The hardware includes the SG160-09 system, external Zephyr Geodetic-2 GNSS antenna, both radio and high-speed Internet communication media. Both acceleration and displacement data was transmitted in real-time to the centralized Data Acquisition Centers for real-time data processing. Command/Control of the field station and real-time GNSS position correction are provided via the Pivot platform. Data from the SG160-09 system was used for seismic event characterization along with data from traditional seismic and geodetic stations installed in the network. Our presentation will focus on the key improvements of the network installation with the SG160-09 system, RTX correction accuracy obtained from Trimble Global RTX tracking network, rapid data transmission, and real-time data processing for strong seismic events and aftershock characterization.
Spot-Welding Gun With Pivoting Twin-Collet Assembly
NASA Technical Reports Server (NTRS)
Nguyen, Francis; Simpson, Gareth; Hoult, William S.
1996-01-01
Modified spot-welding gun includes pivoting twin-collet assembly that holds two spot-welding electrodes. Designed to weld highly conductive (30 percent gold) brazing-alloy foils to thin nickel alloy workpieces; also suitable for other spot-welding applications compatible with two-electrode configuration.
SiRen: Leveraging Similar Regions for Efficient and Accurate Variant Calling
2015-05-30
Cloudera, EMC2, Ericsson, Facebook, Guavus, HP, Huawei, Informatica , Intel, Microsoft, NetApp, Pivotal, Samsung, Schlumberger, Splunk, Virdata and VMware...EMC2, Ericsson, Facebook, Guavus, HP, Huawei, Informatica , Intel, Microsoft, NetApp, Pivotal, Samsung, Schlumberger, Splunk, Virdata and VMware
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adamson, J. C.
1984-01-31
A reflective shutter rotates within a skylight housing in such a fashion as to control solar energy thereby providing a combination of heating, lighting, and ventilation. The skylight housing has three faces: a glazed southern face, a glazed northern face, and an open downwardly oriented face to the interior of the structure. Counter-weighted pivot arms support the shutter at either end causing the center of rotation to pass through the center of gravity. The shutter has three basic positions: In the first position, during the winter day, the shutter closes off the northern face, allowing solar energy to enter directlymore » into the supporting structure providing heat gain and daylighting. In the second position, during the winter night, the shutter closes off the open face to the interior, providing insulation between the structure and the skylight housing. In the third position, during the non-heating season, the shutter closes off the southern face blocking unwanted heat gain but allowing diffuse northern light to penetrate for daylighting. In this last position, a means is provided for ventilating by natural convection. The apparatus can be operated either manually or by motor.« less
Adamson, James C.
1984-01-01
A reflective shutter rotates within a skylight housing in such a fashion as to control solar energy thereby providing a combination of heating, lighting, and ventilation. The skylight housing has three faces: a glazed southern face, a glazed northern face, and an open downwardly oriented face to the interior of the structure. Counter-weighted pivot arms support the shutter at either end causing the center of rotation to pass through the center of gravity. The shutter has three basic positions: In the first position, during the winter day, the shutter closes off the northern face, allowing solar energy to enter directly into the supporting structure providing heat gain and daylighting. In the second position, during the winter night, the shutter closes off the open face to the interior, providing insulation between the structure and the skylight housing. In the third position, during the non-heating season, the shutter closes off the southern face blocking unwanted heat gain but allowing diffuse northern light to penetrate for daylighting. In this last position, a means is provided for ventilating by natural convection. The apparatus can be operated either manually or by motor.
Cammarota, Ryan C; Vollmer, Matthew V; Xie, Jing; Ye, Jingyun; Linehan, John C; Burgess, Samantha A; Appel, Aaron M; Gagliardi, Laura; Lu, Connie C
2017-10-11
Large-scale CO 2 hydrogenation could offer a renewable stream of industrially important C 1 chemicals while reducing CO 2 emissions. Critical to this opportunity is the requirement for inexpensive catalysts based on earth-abundant metals instead of precious metals. We report a nickel-gallium complex featuring a Ni(0)→Ga(III) bond that shows remarkable catalytic activity for hydrogenating CO 2 to formate at ambient temperature (3150 turnovers, turnover frequency = 9700 h -1 ), compared with prior homogeneous Ni-centered catalysts. The Lewis acidic Ga(III) ion plays a pivotal role in stabilizing catalytic intermediates, including a rare anionic d 10 Ni hydride. Structural and in situ characterization of this reactive intermediate support a terminal Ni-H moiety, for which the thermodynamic hydride donor strength rivals those of precious metal hydrides. Collectively, our experimental and computational results demonstrate that modulating a transition metal center via a direct interaction with a Lewis acidic support can be a powerful strategy for promoting new reactivity paradigms in base-metal catalysis.
Light scattering by marine algae: two-layer spherical and nonspherical models
NASA Astrophysics Data System (ADS)
Quirantes, Arturo; Bernard, Stewart
2004-11-01
Light scattering properties of algae-like particles are modeled using the T-matrix for coated scatterers. Two basic geometries have been considered: off-centered coated spheres and centered spheroids. Extinction, scattering and absorption efficiencies, plus scattering in the backward plane, are compared to simpler models like homogeneous (Mie) and coated (Aden-Kerker) models. The anomalous diffraction approximation (ADA), of widespread use in the oceanographic light-scattering community, has also been used as a first approximation, for both homogeneous and coated spheres. T-matrix calculations show that some light scattering values, such as extinction and scattering efficiencies, have little dependence on particle shape, thus reinforcing the view that simpler (Mie, Aden-Kerker) models can be applied to infer refractive index (RI) data from absorption curves. The backscattering efficiency, on the other hand, is quite sensitive to shape. This calls into question the use of light scattering techniques where the phase function plays a pivotal role, and can help explain the observed discrepancy between theoretical and experimental values of the backscattering coefficient in observed in oceanic studies.
2007-05-15
KENNEDY SPACE CENTER, FLA. -- Space Shuttle Atlantis, mounted on a mobile launch platform, finally rests on the hard stand of Launch Pad 39A, straddling the flame trench. This is the second rollout for the shuttle. The flame trench transecting the pad's mound at ground level is 490 feet long, 58 feet wide and 40 feet high. It is made of concrete and refractory brick. Pad structures are insulated from the intense heat of launch by the flame deflector system, which protects the flame trench floor and the pad surface along the top of the flame trench. On the left of the shuttle are the fixed service structure and rotating service structure in open position. When closed, the rotating structure provides protected access to the orbiter for changeout and servicing of payloads at the pad. It is supported by a rotating bridge that pivots about a vertical axis on the west side of the pad's flame trench. The white area in the center is the Payload Changeout Room, an enclosed, environmentally controlled portion of the rotating service structure that supports payload delivery at the launch pad and subsequent vertical installation in the orbiter payload bay. First motion out of the Vehicle Assembly Building was at 5:02 a.m. EDT. In late February, while Atlantis was on the launch pad, Atlantis' external tank received hail damage during a severe thunderstorm that passed through the Kennedy Space Center Launch Complex 39 area. The hail caused visible divots in the giant tank's foam insulation, as well as minor surface damage to about 26 heat shield tiles on the shuttle's left wing. The shuttle was returned to the VAB for repairs. The launch of Space Shuttle Atlantis on mission STS-117 is now targeted for June 8. A flight readiness review will be held on May 30 and 31. Photo credit: NASA/Troy Cryder
Tsai, Liang-Ching; Ren, Yupeng; Gaebler-Spira, Deborah J; Revivo, Gadi A; Zhang, Li-Qun
2017-07-01
This preliminary study examined the effects of off-axis elliptical training on reducing transverse-plane gait deviations and improving gait function in 8 individuals with cerebral palsy (CP) (15.5 ± 4.1 years) who completed an training program using a custom-made elliptical trainer that allows transverse-plane pivoting of the footplates during exercise. Lower-extremity off-axis control during elliptical exercise was evaluated by quantifying the root-mean-square and maximal angular displacement of the footplate pivoting angle. Lower-extremity pivoting strength was assessed. Gait function and balance were evaluated using 10-m walk test, 6-minute-walk test, and Pediatric Balance Scale. Toe-in angles during gait were quantified. Participants with CP demonstrated a significant decrease in the pivoting angle (root mean square and maximal angular displacement; effect size, 1.00-2.00) and increase in the lower-extremity pivoting strength (effect size = 0.91-1.09) after training. Reduced 10-m walk test time (11.9 ± 3.7 seconds vs. 10.8 ± 3.0 seconds; P = 0.004; effect size = 1.46), increased Pediatric Balance Scale score (43.6 ± 12.9 vs. 45.6 ± 10.8; P = 0.042; effect size = 0.79), and decreased toe-in angle (3.7 ± 10.5 degrees vs. 0.7 ± 11.7 degrees; P = 0.011; effect size = 1.22) were observed after training. We present an intervention to challenge lower-extremity off-axis control during a weight-bearing and functional activity for individuals with CP. Our preliminary findings suggest that this intervention was effective in enhancing off-axis control, gait function, and balance and reducing in-toeing gait in persons with CP.
Englund, Erin K; Rodgers, Zachary B; Langham, Michael C; Mohler, Emile R; Floyd, Thomas F; Wehrli, Felix W
2018-02-01
To investigate the relationship between blood flow and oxygen consumption in skeletal muscle, a technique called "Velocity and Perfusion, Intravascular Venous Oxygen saturation and T2*" (vPIVOT) is presented. vPIVOT allows the quantification of feeding artery blood flow velocity, perfusion, draining vein oxygen saturation, and muscle T2*, all at 4-s temporal resolution. Together, the measurement of blood flow and oxygen extraction can yield muscle oxygen consumption ( V˙O2) via the Fick principle. In five subjects, vPIVOT-derived results were compared with those obtained from stand-alone sequences during separate ischemia-reperfusion paradigms to investigate the presence of measurement bias. Subsequently, in 10 subjects, vPIVOT was applied to assess muscle hemodynamics and V˙O2 following a bout of dynamic plantar flexion contractions. From the ischemia-reperfusion paradigm, no significant differences were observed between data from vPIVOT and comparison sequences. After exercise, the macrovascular flow response reached a maximum 8 ± 3 s after relaxation; however, perfusion in the gastrocnemius muscle continued to rise for 101 ± 53 s. Peak V˙O2 calculated based on mass-normalized arterial blood flow or perfusion was 15.2 ± 6.7 mL O 2 /min/100 g or 6.0 ± 1.9 mL O 2 /min/100 g, respectively. vPIVOT is a new method to measure blood flow and oxygen saturation, and therefore to quantify muscle oxygen consumption. Magn Reson Med 79:846-855, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Nishida, Masahiro; Nakayama, Kento; Sakota, Daisuke; Kosaka, Ryo; Maruyama, Osamu; Kawaguchi, Yasuo; Kuwana, Katsuyuki; Yamane, Takashi
2016-06-01
The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
El-Sayed, Wael M; Hussin, Warda A; Al-Faiyz, Yasair S; Ismail, Mohamed A
2013-09-05
The antimutagenic activity of eight novel imidazo[1,2-a]pyridine derivatives (I-VIII) against sodium azide (NaN3) and benzo[a]pyrene (B[a]P) was evaluated using the Salmonella reverse mutation assay. At non-toxic concentrations (12.5-50 µM), imidazopyridines I, II, III, and V with a terminal imidazopyridine group were mutagenic, while derivatives VII and VIII with a central imidazopyridine group were not mutagenic. Compounds IV, VII, and VIII exerted a moderate antimutagenic activity against NaN3 under pre-exposure conditions, and a strong activity (>40%) against B[a]P in the presence of S9 under both pre- and co-exposure conditions and mostly independent on the dose. Imidazopyridines possibly inhibited the microsomal-dependent activation of B[a]P. The demethylated derivative VII was the most active antimutagen. All imidazopyridines had a low to moderate antioxidant activity. The antibacterial activity of imidazopyridines was sporadic and moderate probably due to the failure of bacteria to convert imidazopyridines into active metabolites. The position of imidazopyridine was a pivotal factor in the mutagenic/antimutagenic activity. The strong antimutagenic compounds were dicationic planar compounds with a centered imidazo[1,2-a]pyridine spacer. With LD50 of 60 mg/kg in mice for both derivatives VII and VIII, it is safe to investigate the anticancer activity of these derivatives in animal models. © 2013 Elsevier B.V. All rights reserved.
SANGUINATE (PEGylated Carboxyhemoglobin Bovine): Mechanism of Action and Clinical Update.
Abuchowski, Abraham
2017-04-01
Historically, blood substitutes were under development that would provide oxygen carrying capacity as well as fluid replacement for both trauma and surgical indications. Their development was halted by the inability of the products to deliver therapeutic amounts of oxygen targeted to hypoxic tissue as well as from the inherent toxicity of the molecules. This led to the concept of an oxygen therapeutic that would be targeted for indications caused by anemia/ischemia/hypoxia but would not exhibit the toxicity that plagued earlier products. The complex pathophysiology of diseases such as sickle cell and hemorrhagic stroke not only has hypoxia as a pivotal event but also includes inflammation and vasoconstriction that perpetuate the oxygen deprivation. There is a need for an effective therapeutic that addresses the multiple events of inflammation and oxygen deprivation. SANGUINATE acts as a dual mode carbon monoxide (CO) and oxygen delivery therapeutic. SANGUINATE is designed not only to treat hypoxia but also to act on concurrent pathologies such as inflammation and reperfusion injury. This expands the potential therapeutic utility of SANGUINATE beyond anemia into indications such as early brain injury and delayed kidney graft function, where inflammation plays a pivotal pathological role as well as in indications such as sickle cell disease where the inflammation and hypoxia contribute to the development of comorbidities such as vaso-occlusive crisis. Clinical trials in multiple indications are underway. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Geeslin, Andrew G; Chahla, Jorge; Moatshe, Gilbert; Muckenhirn, Kyle J; Kruckeberg, Bradley M; Brady, Alex W; Coggins, Ashley; Dornan, Grant J; Getgood, Alan M; Godin, Jonathan A; LaPrade, Robert F
2018-05-01
The individual kinematic roles of the anterolateral ligament (ALL) and the distal iliotibial band Kaplan fibers in the setting of anterior cruciate ligament (ACL) deficiency require further clarification. This will improve understanding of their potential contribution to residual anterolateral rotational laxity after ACL reconstruction and may influence selection of an anterolateral extra-articular reconstruction technique, which is currently a matter of debate. Hypothesis/Purpose: To compare the role of the ALL and the Kaplan fibers in stabilizing the knee against tibial internal rotation, anterior tibial translation, and the pivot shift in ACL-deficient knees. We hypothesized that the Kaplan fibers would provide greater tibial internal rotation restraint than the ALL in ACL-deficient knees and that both structures would provide restraint against internal rotation during a simulated pivot-shift test. Controlled laboratory study. Ten paired fresh-frozen cadaveric knees (n = 20) were used to investigate the effect of sectioning the ALL and the Kaplan fibers in ACL-deficient knees with a 6 degrees of freedom robotic testing system. After ACL sectioning, sectioning was randomly performed for the ALL and the Kaplan fibers. An established robotic testing protocol was utilized to assess knee kinematics when the specimens were subjected to a 5-N·m internal rotation torque (0°-90° at 15° increments), a simulated pivot shift with 10-N·m valgus and 5-N·m internal rotation torque (15° and 30°), and an 88-N anterior tibial load (30° and 90°). Sectioning of the ACL led to significantly increased tibial internal rotation (from 0° to 90°) and anterior tibial translation (30° and 90°) as compared with the intact state. Significantly increased internal rotation occurred with further sectioning of the ALL (15°-90°) and Kaplan fibers (15°, 60°-90°). At higher flexion angles (60°-90°), sectioning the Kaplan fibers led to significantly greater internal rotation when compared with ALL sectioning. On simulated pivot-shift testing, ALL sectioning led to significantly increased internal rotation and anterior translation at 15° and 30°; sectioning of the Kaplan fibers led to significantly increased tibial internal rotation at 15° and 30° and anterior translation at 15°. No significant difference was found when anterior tibial translation was compared between the ACL/ALL- and ACL/Kaplan fiber-deficient states on simulated pivot-shift testing or isolated anterior tibial load. The ALL and Kaplan fibers restrain internal rotation in the ACL-deficient knee. Sectioning the Kaplan fibers led to greater tibial internal rotation at higher flexion angles (60°-90°) as compared with ALL sectioning. Additionally, the ALL and Kaplan fibers contribute to restraint of the pivot shift and anterior tibial translation in the ACL-deficient knee. This study reports that the ALL and distal iliotibial band Kaplan fibers restrain anterior tibial translation, internal rotation, and pivot shift in the ACL-deficient knee. Furthermore, sectioning the Kaplan fibers led to significantly greater tibial internal rotation when compared with ALL sectioning at high flexion angles. These results demonstrate increased rotational knee laxity with combined ACL and anterolateral extra-articular knee injuries and may allow surgeons to optimize the care of patients with this injury pattern.
Classroom Pivotal Response Teaching for Children with Autism
ERIC Educational Resources Information Center
Stahmer, Aubyn C.; Suhrheinrich, Jessica; Reed, Sarah; Schreibman, Laura; Bolduc, Cynthia
2011-01-01
This practical manual and accompanying DVD-ROM present a research-supported behavioral intervention for children with autism that teachers can easily integrate into their existing classroom curriculum. Classroom Pivotal Response Teaching (CPRT) enhances children's motivation and participation in learning; increases the number of learning…
20. VIEW TO SOUTHEAST AT CENTERLINE (U37) WHERE SWING SPANS ...
20. VIEW TO SOUTHEAST AT CENTERLINE (U37) WHERE SWING SPANS MEET. PIVOT PIER 1N AT LEFT, PIVOT PIER 1S AT RIGHT. - George P. Coleman Memorial Bridge, Spanning York River at U.S. Route 17, Yorktown, York County, VA
Multiprocessor sparse L/U decomposition with controlled fill-in
NASA Technical Reports Server (NTRS)
Alaghband, G.; Jordan, H. F.
1985-01-01
Generation of the maximal compatibles of pivot elements for a class of small sparse matrices is studied. The algorithm involves a binary tree search and has a complexity exponential in the order of the matrix. Different strategies for selection of a set of compatible pivots based on the Markowitz criterion are investigated. The competing issues of parallelism and fill-in generation are studied and results are provided. A technque for obtaining an ordered compatible set directly from the ordered incompatible table is given. This technique generates a set of compatible pivots with the property of generating few fills. A new hueristic algorithm is then proposed that combines the idea of an ordered compatible set with a limited binary tree search to generate several sets of compatible pivots in linear time. Finally, an elimination set to reduce the matrix is selected. Parameters are suggested to obtain a balance between parallelism and fill-ins. Results of applying the proposed algorithms on several large application matrices are presented and analyzed.
Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca
2012-10-15
Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.
Ellis, Horace; Alexander, Vinette
2016-06-01
There has been renewed, global interest in developing new and transformative models of facilitating access to high-quality, cost-effective, and individually-centered health care for severe mentally-ill (SMI) persons of diverse racial/ethnic, cultural and socioeconomic backgrounds. However, in our present-day health-service delivery systems, scholars have identified layers of barriers to widespread dispersal of well-needed mental health care both nationally and internationally. It is crucial that contemporary models directed at eradicating barriers to mental health services are interdisciplinary in context, design, scope, sequence, and best-practice standards. Contextually, nurses are well-positioned to influence the incorporation and integration of new concepts into operationally interdisciplinary, evidence-based care models with measurable outcomes. The aim of this concept paper is to use the available evidence to contextually explicate how the blended roles of psychiatric mental health (PMH) nursing can be influential in eradicating barriers to care and services for SMI persons through the integrated principles of collaboration, integration and service expansion across health, socioeconomic, and community systems. A large body of literature proposes that any best-practice standards aimed at eliminating barriers to the health care needs of SMI persons require systematic, well-coordinated interdisciplinary partnerships through evidence-based, high-quality, person-centered, and outcome-driven processes. Transforming the conceptual models of collaboration, integration and service expansion could be revolutionary in how care and services are coordinated and dispersed to populations across disadvantaged communities. Building on their longstanding commitment to individual and community care approaches, and their pivotal roles in research, education, leadership, practice, and legislative processes; PMH nurses are well-positioned to be both influential and instrumental in the development of innovative, revolutionary, and transformative paradigmatic models aimed at eradicating treatment barriers, promoting well-being, and reducing preventable mortalities and morbidities among SMI persons. Copyright © 2016 Elsevier Inc. All rights reserved.
Development of confidence limits by pivotal functions for estimating software reliability
NASA Technical Reports Server (NTRS)
Dotson, Kelly J.
1987-01-01
The utility of pivotal functions is established for assessing software reliability. Based on the Moranda geometric de-eutrophication model of reliability growth, confidence limits for attained reliability and prediction limits for the time to the next failure are derived using a pivotal function approach. Asymptotic approximations to the confidence and prediction limits are considered and are shown to be inadequate in cases where only a few bugs are found in the software. Departures from the assumed exponentially distributed interfailure times in the model are also investigated. The effect of these departures is discussed relative to restricting the use of the Moranda model.
Characterization of flexure hinges for the French watt balance experiment
NASA Astrophysics Data System (ADS)
Pinot, Patrick; Genevès, Gérard
2014-08-01
In the French watt balance experiment, the translation and rotation functions must have no backlash, no friction, nor the need for lubricants. In addition errors in position and movement must be below 100 nm. Flexure hinges can meet all of these criteria. Different materials, profile shapes and machining techniques have been studied. The flexure pivots have been characterized using three techniques: 1) an optical microscope and, if necessary, a SEM to observe the surface inhomogeneities; 2) a mass comparator to determine the bending stiffness of unloaded pivots; 3) a loaded beam oscillating freely under vacuum to study the dynamic behavior of loaded pivots.
Work motivation among healthcare professionals.
Kjellström, Sofia; Avby, Gunilla; Areskoug-Josefsson, Kristina; Andersson Gäre, Boel; Andersson Bäck, Monica
2017-06-19
Purpose The purpose of this paper is to explore work motivation among professionals at well-functioning primary healthcare centers subject to a national healthcare reform which include financial incentives. Design/methodology/approach Five primary healthcare centers in Sweden were purposively selected for being well-operated and representing public/private and small/large units. In total, 43 interviews were completed with different medical professions and qualitative deductive content analysis was conducted. Findings Work motivation exists for professionals when their individual goals are aligned with the organizational goals and the design of the reform. The centers' positive management was due to a unique combination of factors, such as clear direction of goals, a culture of non-hierarchical collaboration, and systematic quality improvement work. The financial incentives need to be translated in terms of quality patient care to provide clear direction for the professionals. Social processes where professionals work together as cohesive groups, and provided space for quality improvement work is pivotal in addressing how alignment is created. Practical implications Leaders need to consistently translate and integrate reforms with the professionals' drives and values. This is done by encouraging participation through teamwork, time for structured reflection, and quality improvement work. Social implications The design of the reforms and leadership are essential preconditions for work motivation. Originality/value The study offers a more complete picture of how reforms are managed at primary healthcare centers, as different medical professionals are included. The value also consists of showing how a range of aspects combine for primary healthcare professionals to successfully manage external reforms.
The Gravitation of the Moon Plays Pivotal Roles in the Occurrence of the Acute Myocardial Infarction
Wake, Ryotaro; Yoshikawa, Junichi; Haze, Kazuo; Otani, Shinichiro; Yoshimura, Takayoshi; Toda, Iku; Nishimoto, Masaki; Kawarabayashi, Takahiko; Tanaka, Atsushi; Shimada, Kenei; Iida, Hidetaka; Takeuchi, Kazuhide; Yoshiyama, Minoru
2008-01-01
Acute myocardial infarction (AMI) is a social burden. However, being able to predict AMI could lead to prevention. A previous study showed only the relation between the lunar phase and the occurrence of AMI, but the period it takes for the moon to orbit around the earth and the period of the lunar phase differ. This study investigated the effect of the gravitation of the moon on AMI. Data was comprised of 1369 consecutive patients with first AMI at 5 hospitals from October, 1984 to December, 1997. The universal gravitation of the moon was calculated and compared to the earth onset time of AMI. Universal gravitation of the moon was derived by G*m/d2 (G: universal gravitation constant, m: the mass of the moon, d: the distance between the center of the moon and the center of the earth). The relationship between m/d2 and the cases of AMI was determined. There was an increase in cases, when there is a distance of more than 399864 km from the center of the earth to the center of the moon. The gravitation of more than 399864 km was determined to be weaker gravitation. It is confirmed that the number of AMI patients significantly increases at weaker gravitation periods in this multicenter trial. In conclusion, these results suggest that the gravitation of the moon may have an influence on the occurrence of AMI. PMID:21572849
ELECTRIC FURNACES TILT AROUND A PIVOT UNDER THE SPOUT TO ...
ELECTRIC FURNACES TILT AROUND A PIVOT UNDER THE SPOUT TO FILL BULL LADLES BELOW THE CHARGING DECK. THE REAR VIEW OF A POURING ELECTRIC FURNACE FROM THE CHARGING DECK IS SHOWN HERE. - Southern Ductile Casting Company, Melting, 2217 Carolina Avenue, Bessemer, Jefferson County, AL
Effectiveness of Community-Based Early Intervention Based on Pivotal Response Treatment
ERIC Educational Resources Information Center
Smith, Isabel M.; Flanagan, Helen E.; Garon, Nancy; Bryson, Susan E.
2015-01-01
Preschoolers (n = 118) with autism spectrum disorder (ASD) participated in this prospective effectiveness study of an early intervention program. Treatment entailed parent training and therapist-implemented components, incorporating Pivotal Response Treatment and Positive Behaviour Support. Standardized ability and behavioural measures were…
The Diamond Model of Intrusion Analysis
2013-07-05
infrastructure pivot) which were then “ sinkholed ”12 to identify global victims (infrastructure-to-victim pivot). Each victim was then further identified...which would have matching social-political needs using cyber-victimology (§5.1.2) [43]. 12“ Sinkholing ” is an aggressive defender technique to takeover
Thrust stand for vertically oriented electric propulsion performance evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moeller, Trevor; Polzin, Kurt A.
A variation of a hanging pendulum thrust stand capable of measuring the performance of an electric thruster operating in the vertical orientation is presented. The vertical orientation of the thruster dictates that the thruster must be horizontally offset from the pendulum pivot arm, necessitating the use of a counterweight system to provide a neutrally stable system. Motion of the pendulum arm is transferred through a balance mechanism to a secondary arm on which deflection is measured. A noncontact light-based transducer is used to measure displacement of the secondary beam. The members experience very little friction, rotating on twisting torsional pivotsmore » with oscillatory motion attenuated by a passive, eddy-current damper. Displacement is calibrated using an in situ thrust calibration system. Thermal management and self-leveling systems are incorporated to mitigate thermal and mechanical drifts. Gravitational force and torsional spring constants associated with flexure pivots provide restoring moments. An analysis of the design indicates that the thrust measurement range spans roughly four decades, with the stand capable of measuring thrust up to 12 N for a 200 kg thruster and up to approximately 800 mN for a 10 kg thruster. Data obtained from calibration tests performed using a 26.8 lbm simulated thruster indicated a resolution of 1 mN on 100 mN level thrusts, while those tests conducted on a 200 lbm thruster yielded a resolution of roughly 2.5 mN at thrust levels of 0.5 N and greater.« less
Thrust Stand for Electric Propulsion Performance Evaluation
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Markusic, Thomas E.; Stanojev, Boris J.; Dehoyos, Amado; Spaun, Benjamin
2006-01-01
An electric propulsion thrust stand capable of supporting testing of thrusters having a total mass of up to 125 kg and producing thrust levels between 100 microN to 1 N has been developed and tested. The design features a conventional hanging pendulum arm attached to a balance mechanism that converts horizontal deflections produced by the operating thruster into amplified vertical motion of a secondary arm. The level of amplification is changed through adjustment of the location of one of the pivot points linking the system. Response of the system depends on the relative magnitudes of the restoring moments applied by the displaced thruster mass and the twisting torsional pivots connecting the members of the balance mechanism. Displacement is measured using a non-contact, optical linear gap displacement transducer and balance oscillatory motion is attenuated using a passive, eddy-current damper. The thrust stand employs an automated leveling and thermal control system. Pools of liquid gallium are used to deliver power to the thruster without using solid wire connections, which can exert undesirable time-varying forces on the balance. These systems serve to eliminate sources of zero-drift that can occur as the stand thermally or mechanically shifts during the course of an experiment. An in-situ calibration rig allows for steady-state calibration before, during and after thruster operation. Thrust measurements were carried out on a cylindrical Hall thruster that produces mN-level thrust. The measurements were very repeatable, producing results that compare favorably with previously published performance data, but with considerably smaller uncertainty.
NASA Technical Reports Server (NTRS)
Muratore, John F.
2007-01-01
Space Rescue has been a topic of speculation for a wide community of people for decades. Astronauts, aerospace engineers, diplomats, medical and rescue professionals, inventors and science fiction writers have all speculated on this problem. Martin Caidin's 1964 novel Marooned dealt with the problems of rescuing a crew stranded in low earth orbit. Legend at the Johnson Space Center says that Caidin's portrayal of a Russian attempt to save the American crew played a pivotal role in convincing the Russians to join the real joint Apollo-Soyuz mission. Space Rescue has been a staple in science fiction television and movies portrayed in programs such as Star Trek, Stargate-SG1 and Space 1999 and movies such as Mission To Mars and Red Planet. As dramatic and as difficult as rescue appears in fictional accounts, in the real world it has even greater drama and greater difficulty. Space rescue is still in its infancy as a discipline and the purpose of this chapter is to describe the issues associated with space rescue and the work done so far in this field. For the purposes of this chapter, the term space rescue will refer to any system which allows for rescue or escape of personnel from situations which endanger human life in a spaceflight operation. This will span the period from crew ingress prior to flight through crew egress postlanding. For the purposes of this chapter, the term primary system will refer to the spacecraft system that a crew is either attempting to escape from or from which an attempt is being made to rescue the crew.
Wagner, Peter D
2012-01-01
Exercise is the example par excellence of the body functioning as a physiological system. Conventionally we think of the O(2) transport process as a major manifestation of that system linking and integrating pulmonary, cardiovascular, hematological and skeletal muscular contributions to the task of getting O(2) from the air to the mitochondria, and this process has been well described. However, exercise invokes system responses at levels additional to those of macroscopic O(2) transport. One such set of responses appears to center on muscle intracellular PO(2), which falls dramatically from rest to exercise. At rest, it approximates 4 kPa, but during heavy endurance exercise it falls to about 0.4-0.5 kPa, an amazingly low value for a tissue absolutely dependent on the continual supply of O(2) to meet very high energy demands. One wonders why intracellular PO(2) is allowed to fall to such levels. The proposed answer, to be presented in the review, is that a low intramyocyte PO(2) is pivotal in: (a) optimizing oxygen's own physiological transport, and (b) stimulating adaptive gene expression that, after translation, enables greater exercise capacity-all the while maintaining PO(2) at levels sufficient to allow oxidative phosphorylation to operate sufficiently fast enough to support intense muscle contraction. Thus, during exercise, reductions of intracellular PO(2) to less than 1% of that in the atmosphere enables an integrated response that fundamentally and simultaneously optimizes physiological, biochemical and molecular events that support not only the exercise as it happens but the adaptive changes to increase exercise capacity over the longer term.
Murzuk Sand Sea, Sahara Desert, Libya, Africa
1993-01-19
STS054-152-189 (13-19 Jan. 1993) --- This near-vertical color photograph shows the very diverse landscape that is part of the great Sahara Desert of north Africa. Specifically, the vast expanse of sand dunes, located in the extreme southwestern corner of Libya, is known as the Murzuk Sand Sea. Close inspection of this photograph shows the agricultural village of Murzuk as evidenced by the numerous center pivot irrigation patterns at the edge of the Murzuk Sand Sea. The very rugged, dissected terrain to the west of this sand sea is the eastern tip of the Tassili N'ajjer Mountains and the Tadrart Plateau that are in neighboring Algeria. Several smaller areas of sand dunes are interspersed between the major areas of rock outcrops. The photograph was taken with a Linhof camera.
Zschaeck, Sebastian; Lohaus, Fabian; Beck, Marcus; Habl, Gregor; Kroeze, Stephanie; Zamboglou, Constantinos; Koerber, Stefan Alexander; Debus, Jürgen; Hölscher, Tobias; Wust, Peter; Ganswindt, Ute; Baur, Alexander D J; Zöphel, Klaus; Cihoric, Nikola; Guckenberger, Matthias; Combs, Stephanie E; Grosu, Anca Ligia; Ghadjar, Pirus; Belka, Claus
2018-05-11
68 Gallium prostate specific membrane antigen (PSMA) ligand positron emission tomography (PET) is an increasingly used imaging modality in prostate cancer, especially in cases of tumor recurrence after curative intended therapy. Owed to the novelty of the PSMA-targeting tracers, clinical evidence on the value of PSMA-PET is moderate but rapidly increasing. State of the art imaging is pivotal for radiotherapy treatment planning as it may affect dose prescription, target delineation and use of concomitant therapy.This review summarizes the evidence on PSMA-PET imaging from a radiation oncologist's point of view. Additionally a short survey containing twelve examples of patients and 6 additional questions was performed in seven mayor academic centers with experience in PSMA ligand imaging and the findings are reported here.
Kansas environmental and resource study: A Great Plains model
NASA Technical Reports Server (NTRS)
Haralick, R. M.; Kanemasu, E. T.; Morain, S. A.; Yarger, H. L.; Ulaby, F. T. (Principal Investigator)
1973-01-01
The land use category of subimage regions over Kansas within an MSS image can be identified with an accuracy of about 70% using the textural-spectral features of the multi-images from the four MSS bands. Ground truth measurements indicate that reflectance ratios of the 545 and 655 nm wavebands provide an index of plant development and possibly physiological stress. Agricultural consultants have expressed substantial interest in work conducted on center pivot irrigation and have inquired as to how they may use ERTS-1 imagery to aid those in the irrigation field. Results of the land use mapping experiment indicate that ERTS-1 imagery has major potential in regionalization. The ways in which land is utilized within these regions may then be studied more effectively than if no adequate regionalization is available.
Site Description for the University of Nebraska's Sandhills Agricultural Laboratory
NASA Technical Reports Server (NTRS)
Gardner, B. R.; Blad, B. L.
1985-01-01
The Sandhills Agricultural Laboratory is operated by the University of Nebraska. The laboratory is located in the south-central part of the Nebraska Sandhills near Tryon, Nebraska (41 deg. 37' N; 100 deg. 50' W). The laboratory is surrounded on the west and south by native rangeland vegetation, on the south by a large field of corn irrigated by a center pivot, and on the east by wheat stubble. This site is appropriate for moisture stress studies since rainfall is almost always inadequate to meet evaporative demands of agricultural crops during most of the growing season and the sandy soils (Valentine fine sand) at the site do not store large quantities of water. Various levels of water stress are achieved through irrigation from solid set sprinklers.
Intrinsic motivation: how can it play a pivotal role in changing clinician behaviour?
Nantha, Yogarabindranath Swarna
2013-01-01
In the light of an increasing healthcare burden, this paper seeks to offer insight about how intrinsic motivation could play a pivotal role in improving the pre-existing healthcare service delivery systems by altering clinician behaviour. The paper argues the case for four salient dimensions worth exploring through the lens of intrinsic motivation--non-financial incentives, positive affective states, organizational culture and prescribing quality. This article reviews literature from both social sciences and health management practices to provide rationale on how intrinsic motivational approaches could optimize healthcare service delivery systems. The scrutiny of the body of evidence leads to the assertion that there is neglect in the initiatives to reinforce intrinsic motivation as a method to address the ailing morale of doctors. This seems to have exacerbated negative outcomes that include job dissatisfaction, compromise in the quality of care and poor patient-doctor relationships. Diminution in positive affective states amongst doctors, largely controlled by intrinsic motivation, led to strained doctor-patient communication and poor quality of care. Barriers in a healthcare organizational culture that restricts autonomy and empowerment seem to directly undermine job satisfaction. The article argues that it is crucial to shift away from the conventional tendencies promoting tangible rewards. A more holistic approach should be adopted by conducting formal research into intrinsic motivation and how it could aid the formulation of policies tailored to meet the current demands of the healthcare system.
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
Wessler, Stephen
This publication focuses on initiatives that are designed to address hate crimes by enhancing efforts of the criminal justice system. After discussing the pivotal role of law enforcement in this effort, the paper describes six Bureau of Justice Assistance-funded initiatives, which include: the International Association of Chiefs of Police Summit:…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2013
2013-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
Mishra, Mukti
2014-01-01
At present, India's education system turns out millions of young people who are ready to think, but not enough people with entrepreneurial or employment skills. As India faces increasing limits on its resources, both economic and natural, the competency and capability of human resources play a pivotal role in developing and sustaining the economy.…
Children of Two to Three Years of Age in France: Early Childhood Settings and Age Divisions
ERIC Educational Resources Information Center
Garnier, Pascale; Rayna, Sylvie; Brougère, Gilles; Rupin, Pablo
2017-01-01
In a French early childhood care and education system that is strongly divided by age and institution, the current research studies the collective life of children at the pivotal age of two to three years of age in four different early childhood settings: (1) a group of "grands" (nursery) in a "crèche" (daycare centre), (2) a…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
District of Columbia Public Schools, 2012
2012-01-01
The 2012-2013 school year represents a pivotal juncture for DC Public Schools. Last spring, Mayor Gray and Chancellor Kaya Henderson introduced "A Capital Commitment," their ambitious plan to dramatically accelerate student achievement in the district over the next five years by providing all of their students with a safe, academically…
ERIC Educational Resources Information Center
Sachser, Ricardo Marcelo; Crestani, Ana Paula; Quillfeldt, Jorge Alberto; e Souza, Tadeu Mello; de Oliveira Alvares, Lucas
2015-01-01
Despite the fact that the cannabinoid receptor type 1 (CB1R) plays a pivotal role in emotional memory processing in different regions of the brain, its function in the retrosplenial cortex (RSC) remains unknown. Here, using contextual fear conditioning in rats, we showed that a post-training intra-RSC infusion of the CB1R antagonist AM251…
Large capacity oblique all-wing transport aircraft
NASA Technical Reports Server (NTRS)
Galloway, Thomas L.; Phillips, James A.; Kennelly, Robert A., Jr.; Waters, Mark H.
1996-01-01
Dr. R. T. Jones first developed the theory for oblique wing aircraft in 1952, and in subsequent years numerous analytical and experimental projects conducted at NASA Ames and elsewhere have established that the Jones' oblique wing theory is correct. Until the late 1980's all proposed oblique wing configurations were wing/body aircraft with the wing mounted on a pivot. With the emerging requirement for commercial transports with very large payloads, 450-800 passengers, Jones proposed a supersonic oblique flying wing in 1988. For such an aircraft all payload, fuel, and systems are carried within the wing, and the wing is designed with a variable sweep to maintain a fixed subsonic normal Mach number. Engines and vertical tails are mounted on pivots supported from the primary structure of the wing. The oblique flying wing transport has come to be known as the Oblique All-Wing (OAW) transport. This presentation gives the highlights of the OAW project that was to study the total concept of the OAW as a commercial transport.
NASA Technical Reports Server (NTRS)
Tittel, Frank K. (Inventor); Curl, Robert F. (Inventor); Wysocki, Gerard (Inventor)
2010-01-01
A widely tunable, mode-hop-free semiconductor laser operating in the mid-IR comprises a QCL laser chip having an effective QCL cavity length, a diffraction grating defining a grating angle and an external cavity length with respect to said chip, and means for controlling the QCL cavity length, the external cavity length, and the grating angle. The laser of claim 1 wherein said chip may be tuned over a range of frequencies even in the absence of an anti-reflective coating. The diffraction grating is controllably pivotable and translatable relative to said chip and the effective QCL cavity length can be adjusted by varying the injection current to the chip. The laser can be used for high resolution spectroscopic applications and multi species trace-gas detection. Mode-hopping is avoided by controlling the effective QCL cavity length, the external cavity length, and the grating angle so as to replicate a virtual pivot point.
A Hierarchical Security Architecture for Cyber-Physical Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quanyan Zhu; Tamer Basar
2011-08-01
Security of control systems is becoming a pivotal concern in critical national infrastructures such as the power grid and nuclear plants. In this paper, we adopt a hierarchical viewpoint to these security issues, addressing security concerns at each level and emphasizing a holistic cross-layer philosophy for developing security solutions. We propose a bottom-up framework that establishes a model from the physical and control levels to the supervisory level, incorporating concerns from network and communication levels. We show that the game-theoretical approach can yield cross-layer security strategy solutions to the cyber-physical systems.
Transport as a system: reorganization of perinatal assistance in Northern Lombardy.
Martinelli, Stefano; Vergani, Patrizia; Zanini, Rinaldo; Bellù, Roberto; Farina, Clotilde; Tagliabue, Paolo
2011-10-01
The organization of perinatal care has been a pivotal mean for improvement in neonatal survivals. Despite the excellent standard of assistance in Lombardy, Obstetrics and Neonatal Units of MBBM Foundation-Monza, Manzoni Hospital-Lecco and Niguarda Hospital-Milan put forward a pilot project proposing reorganization of perinatal care in the northern part of Lombardy. The main goals of the project are implementation of maternal transport system and use of neonatal back transport as a system to increase the availability of intensive care beds. The project's fundamental steps and critical points will be discussed.
A Gimbal sizing analysis for an IPACS rotating assembly
NASA Technical Reports Server (NTRS)
Burke, P. R.; Coronato, P. A.
1985-01-01
All major components of an integrated power/attitude control system (IPACS) assembly were analyzed for testing, launch, and operational stresses. The conceptual design for the outer gimbal and mounting ring structures were developed and analyzed along with preliminary designs of the pivot and torquer assemblies. Results from the system response analysis and the thermal analysis are also presented. Gimballing of this rotating assembly should present few difficulties as the maximum gimballing rate is quite low. However, the inner gimbal assembly in its current configuration must be modified to develop the system from a laboratory concept to a realistic flight hardware status.
Grelier, S; Thetio, M; Quentin, V; Achache, V; Sanchez, N; Leroux, V; Durand, E; Pequignot, R
2011-03-01
The National Hospital of Saint Maurice (HNSM) for Physical Medicine and Rehabilitation aims at strengthening its position as a pivot rehabilitation and physical therapy center. The opening in 2011 of a new unit for the evaluation and treatment of motor disabilities meets this objective. This project includes several parts: clinical, financial, architectural, organizational, applied clinical research as well as dealing with medical equipments and information system. This study focuses on the risk assessment of this future technical unit. This study was conducted by a group of professionals working for the hospital. It started with the design of a functional model to better comprehend the system to be analyzed. Risk assessment consists in confronting this functional model to a list of dangers in order to determine the vulnerable areas of the system. Then the team designed some scenarios to identify the causes, securities barriers and consequences in order to rank the risks. The analysis targeted various dangers, e.g. political, strategic, financial, economical, marketing, clinical and operational. The team identified more than 70 risky scenarios. For 75% of them the criticality level was deemed initially tolerable and under control or unacceptable. The implementation of an action plan for reducing the level of risks before opening this technical unit brought the system down to an acceptable level at 66%. A year prior to opening this technical unit for the evaluation and treatment of motor disabilities, conducting this preliminary risk assessment, with its exhaustive and rigorous methodology, enabled the concerned professionals to work together around an action plan for reducing the risks. 2011 Elsevier Masson SAS. All rights reserved.
75 FR 7931 - Airworthiness Directives; Airbus Model A380-841, -842, and -861 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... addition, delamination has been observed within the monolithic Carbon Fibre Reinforced Plastic (CFRP... observed within the monolithic Carbon Fibre Reinforced Plastic (CFRP) structure around the pivot support... monolithic Carbon Fibre Reinforced Plastic (CFRP) structure around the pivot support-ring. This condition, if...
Twelve Great Basketball Offenses.
ERIC Educational Resources Information Center
Healey, William A.; Hartley, Joseph W.
Features and merits of twelve offensive basketball patterns are presented in this volume. Plays described are: (1) single pivot-post offense; (2) double pivot-post offense; (3) weak-side cutter series (reverse action offense); (4) 1-3-1 offense (hi-lo offense); (5) Illinois continuity offense; (6) rotation offense; (7) shuffle offense; (8) pick…
Pivotal Teaching Moments in Technology-Intensive Secondary Geometry Classrooms
ERIC Educational Resources Information Center
Cayton, Charity; Hollebrands, Karen; Okumus, Samet; Boehm, Ethan
2017-01-01
This study investigates three teachers' uses of a dynamic geometry program (The Geometer's Sketchpad) in their high school geometry classes over a 2-year period. The researchers examine teachers' actions and questions during pivotal teaching moments to characterize mathematics instruction that utilizes technology. Findings support an association…
49 CFR 178.337-3 - Structural integrity.
Code of Federal Regulations, 2013 CFR
2013-10-01
... each case, the forces applied must be 0.35 times the vertical reaction at the suspension assembly... assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel) or turntable; or... reaction at the suspension assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel...
49 CFR 178.337-3 - Structural integrity.
Code of Federal Regulations, 2012 CFR
2012-10-01
... each case, the forces applied must be 0.35 times the vertical reaction at the suspension assembly... assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel) or turntable; or... reaction at the suspension assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel...
49 CFR 178.337-3 - Structural integrity.
Code of Federal Regulations, 2014 CFR
2014-10-01
... each case, the forces applied must be 0.35 times the vertical reaction at the suspension assembly... assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel) or turntable; or... reaction at the suspension assembly of a trailer; or the horizontal pivot of the upper coupler (fifth wheel...
Examination of Studies Targeting Social Skills with Pivotal Response Treatment
ERIC Educational Resources Information Center
Bozkus Genc, Gulden; Vuran, Sezgin
2013-01-01
In early education, especially in effective teaching to children with autism spectrum disorders, the teaching methods which are applicable in natural settings like pivotal response treatment (PRT) are commonly used. It is one of the naturalistic intervention models aiming to facilitate the stimulant-response generalization, decrease the dependency…
Tanaka, Yoshiya; Bass, Damon; Chu, Myron; Egginton, Sally; Ji, Beulah; Struemper, Herbert; Roth, David
2018-05-24
To assess the efficacy and safety of intravenous belimumab plus standard systemic lupus erythematosus (SLE) therapy (SoC) in Japanese patients with SLE. A Phase 3, multicenter, double-blind, placebo-controlled, 52-week study (BEL 113750; NCT01345253) in patients with SLE, randomized 2:1 to belimumab 10 mg/kg plus SoC or placebo plus SoC to Week 48. Sixty of 707 randomized patients were enrolled from study centers in Japan (belimumab, n = 39; placebo, n = 21). In this cohort, more patients achieved SLE Responder Index 4 response at Week 52 in the belimumab group compared with placebo (46.2% [18/39] vs 25.0% [5/20]; odds ratio, 2.57 [95% confidence interval: 0.78, 8.47]; p = 0.1204). Fewer patients receiving belimumab experienced a severe flare through Week 52, with longer median time to flare compared with placebo. More patients with baseline prednisone dose >7.5 mg/day receiving belimumab had a dose reduction of ≥25% from baseline to ≤7.5 mg/day during Weeks 40 to 52, compared with placebo. No new safety issues were identified within the Japanese cohort. In Japanese patients with SLE, belimumab improved disease activity, with efficacy and safety results similar and consistent to the pivotal Phase 3 trials, suggesting that belimumab is a potential treatment option in this population.
U.S. national response assets for radiological incidents.
Remick, Alan L; Crapo, John L; Woodruff, Charles R
2005-11-01
The federal government has had the ability to respond to incidents of national significance for decades. Since 11 September 2001, there have been enhancements to existing federal assets and the creation of new federal assets. This presentation will provide an overview of the more significant federal assets. Pivotal to a response of national significance is the U.S. Department of Energy (DOE) Federal Radiological Monitoring and Assessment Center, which organizes and coordinates federal agency monitoring activities during an emergency. DOE manages the Federal Radiological Monitoring and Assessment Center during the emergency phase, and the Environmental Protection Agency (EPA) manages the response during the recovery phase once the emergency is terminated. EPA monitoring teams provide support during both the emergency and recovery phases of an emergency. Other DOE teams are available to respond to major nuclear power plant events, transportation accidents, or terrorism events involving the use of radiological materials, including the Radiological Assistance Program, the Aerial Measuring System, the National Atmospheric Release Advisory Center, and the Radiation Emergency Assistance Center/Training Site. For incidents involving a nuclear weapon, an improvised nuclear device, or a radiological dispersal device, DOE assets such as the Nuclear Emergency Support Team and the Accident Response Group could provide capabilities for weapon or device search, recovery, and removal. The Radiological Triage System harnesses the weapons scientists and engineers at the DOE national laboratories to provide gamma spectroscopy interpretation for agencies responding to an incident. In recent years, National Guard Weapons of Mass Destruction-Civil Support Teams have been created to support state and local response to terrorism events. The Civil Support Teams normally come under direct control of the state and can respond without requiring authorization from the U.S. Department of Defense (DoD). Changes brought about by the events of September 11 also extend to changing federal response policy and planning. Therefore, the Catastrophic Incident Response Annex to the National Response Plan is discussed. DoD also provides specifically designated radiological response capabilities that can be utilized within the guidelines of the National Response Plan. While optimally designed to support military missions, these resources also help provide for a well-equipped set of national assets to temporarily support and augment the local, state, and federal civil agencies that have primary authority and responsibility for domestic disaster assistance. The military's role in domestic emergencies is well defined in military regulations, as well as the national plan.
NASA Astrophysics Data System (ADS)
Hester, R. E., Jr.
2015-12-01
The study considers a north-south pair of mid-latitude rings of atmospheric mass, symmetric with respect to the equator, and rotating with respect to the distant stars. The mass and angular velocity are assigned similar to the annual and zonal mean upper level westerlies. Their relatively rapid rotation is assumed to allow a rigid body approximation on long time and space scales. The rings are constrained to move as if rigidly connected to a common axis of rotation. The pair thus constitutes a symmetric top with a fixed pivot point at the center of mass. Analysis of the dynamics follows the classical mechanics approach used for precession of the equinoxes. The theoretical rate of precession for this highly idealized system yields a period on the order of decades. The predicted dynamics appears consistent with three prior studies of observational data: latitudinal movements of atmospheric circulation above far Southern Australia, latitudinal movements of ocean circulation in the Kuroshio Extension, and changes in global Atmospheric Angular Momentum before and after 1976. Each of these observational records indicates correlation with the Pacific Decadal Oscillation. The theoretical dynamics in combination with the observations suggests the axis of rotation of the atmospheric westerlies is offset from the Earth axis by a few degrees, and further, that this axis precesses around a mean axis on a time scale of a few decades.
Clinical excellence in academia: perspectives from masterful academic clinicians.
Christmas, Colleen; Kravet, Steven J; Durso, Samuel C; Wright, Scott M
2008-09-01
To better understand and characterize clinical excellence in academia by exploring the perspectives of clinically excellent faculty in the top American departments of medicine. Between March 1 and May 31, 2007, 2 investigators conducted in-depth semistructured interviews with 24 clinically excellent Department of Medicine physicians at 8 academic institutions. Interview transcripts were independently analyzed by 2 investigators and compared for agreement. Content analysis identified several major themes that relate to clinical excellence in academia. Physicians hailed from a range of internal medicine specialties; 20 (83%) were associate professors or professors and 8 (33%) were women. The mean percentage of time physicians spent in clinical care was 48%. Eight domains emerged as the major features of clinical excellence in academia: reputation, communication and interpersonal skills, professionalism and humanism, diagnostic acumen, skillful negotiation of the health care system, knowledge, scholarly approach to clinical care, and passion for clinical medicine. Understanding the core elements that contribute to clinical excellence in academia represents a pivotal step to defining clinical excellence in this setting. It is hoped that such work will lead to initiatives aimed at measuring and rewarding clinical excellence in our academic medical centers such that the most outstanding clinicians feel valued and decide to stay in academia to serve as role models for medical trainees.
NASA Technical Reports Server (NTRS)
Callicott, William M.
1992-01-01
NOAA has 11 terabytes of digital data stored on 240,000 computer tapes. There are an additional 100 terabytes (TB) of geostationary satellite data stored in digital form on specially configured SONY U-Matic video tapes at the University of Wisconsin. There are over 90,000,000 non-digital form records in manuscript, film, printed, and chart form which are not easily accessible. The three NOAA Data Centers service 6,000 requests per year and publish 5,000 bulletins which are distributed to 40,000 subscribers. Seventeen CD-ROM's have been produced. Thirty thousand computer tapes containing polar satellite data are being copied to 12 inch WORM optical disks for research applications. The present annual data accumulation rate of 10 TB will grow to 30 TB in 1994 and to 100 TB by the year 2000. The present storage and distribution technologies with their attendant support systems will be overwhelmed by these increases if not improved. Increased user sophistication coupled with more precise measurement technologies will demand better quality control mechanisms, especially for those data maintained in an indefinite archive. There is optimism that the future will offer improved media technologies to accommodate the volumes of data. With the advanced technologies, storage and performance monitoring tools will be pivotal to the successful long-term management of data and information.
Washetine, Kevin; Kara-Borni, Mehdi; Heeke, Simon; Bonnetaud, Christelle; Félix, Jean-Marc; Ribeyre, Lydia; Bence, Coraline; Ilié, Marius; Bordone, Olivier; Pedro, Marine; Maitre, Priscilla; Tanga, Virginie; Gormally, Emmanuelle; Mossuz, Pascal; Lorimier, Philippe; Marquette, Charles Hugo; Mouroux, Jérôme; Cohen, Charlotte; Lassalle, Sandra; Long-Mira, Elodie; Clément, Bruno; Dagher, Georges; Hofman, Véronique; Hofman, Paul
2018-06-11
Collected specimens for research purposes may or may not be made available depending on their scarcity and/or on the project needs. Their protection against degradation or in the event of an incident is pivotal. Duplication and storage on a different site is the best way to assure their sustainability. The conservation of samples at room temperature (RT) by duplication can facilitate their protection. We describe a security system for the collection of non-small cell lung cancers (NSCLC) stored in the biobank of the Nice Hospital Center, France, by duplication and conservation of lyophilized (dried), encapsulated DNA kept at RT. Therefore, three frozen tissue collections from non-smoking, early stage and sarcomatoid carcinoma NSCLC patients were selected for this study. DNA was extracted, lyophilized and encapsulated at RT under anoxic conditions using the DNAshell technology. In total, 1974 samples from 987 patients were encapsulated. Six and two capsules from each sample were stored in the biobanks of the Nice and Grenoble (France) Hospitals, respectively. In conclusion, DNA maintained at RT allows for the conservation, duplication and durability of collections of interest stored in biobanks. This is a low-cost and safe technology that requires a limited amount of space and has a low environmental impact.