Sample records for central control panel

  1. [Plug-in Based Centralized Control System in Operating Rooms].

    PubMed

    Wang, Yunlong

    2017-05-30

    Centralized equipment controls in an operating room (OR) is crucial to an efficient workflow in the OR. To achieve centralized control, an integrative OR needs to focus on designing a control panel that can appropriately incorporate equipment from different manufactures with various connecting ports and controls. Here we propose to achieve equipment integration using plug-in modules. Each OR will be equipped with a dynamic plug-in control panel containing physically removable connecting ports. Matching outlets will be installed onto the control panels of each equipment used at any given time. This dynamic control panel will be backed with a database containing plug-in modules that can connect any two types of connecting ports common among medical equipment manufacturers. The correct connecting ports will be called using reflection dynamics. This database will be updated regularly to include new connecting ports on the market, making it easy to maintain, update, expand and remain relevant as new equipment are developed. Together, the physical panel and the database will achieve centralized equipment controls in the OR that can be easily adapted to any equipment in the OR.

  2. 14. DETAIL OF EAST END OF CENTRAL CONTROL CONSOLE IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. DETAIL OF EAST END OF CENTRAL CONTROL CONSOLE IN SLC-3W CONTROL ROOM SHOWING BLANK PANEL AND COMPLEX SAFETY OFFICER PANEL. CONSOLES AND CHAIRS NEAR NORTH WALL IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. 16. VIEW OF THE STATIONARY OPERATING ENGINEER CONTROL PANEL INSTALLATION. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. VIEW OF THE STATIONARY OPERATING ENGINEER CONTROL PANEL INSTALLATION. THE PANEL CONTROLS AIR-HANDLING EQUIPMENT AND AIR PRESSURE WITHIN THE BUILDING. (10/6/69) - Rocky Flats Plant, Plutonium Manufacturing Facility, North-central section of Plant, just south of Building 776/777, Golden, Jefferson County, CO

  4. Multipurpose Panel Display Device Investigation. [technology assessment and product development

    NASA Technical Reports Server (NTRS)

    Sliwa, R.

    1977-01-01

    A multipurpose panel was developed to provide a flexible control and a LED display panel with easily changeable nomenclature for use in applications where panel space is limited, but where a number of similar subsystems must be controlled, or where basic panel nomenclature and functions must be changed rapidly, as in the case of between mission changes of space shuttle payloads. In the first application, panel area limitations are overcome by time sharing a central control panel among several subsystems. In the latter case, entire control panel changes are effected by simply replacing a memory module, thereby reducing the extent of installation and checkout procedures between missions. Several types of control technologies (other than LED's) which show potential in meeting criteria for overcoming limitations of the panel are assessed.

  5. 2. VIEW OF THE EXPERIMENT CONTROL PANEL IN 1970. THE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW OF THE EXPERIMENT CONTROL PANEL IN 1970. THE NUCLEAR SAFETY GROUP CONDUCTED ABOUT 1,700 CRITICAL MASS EXPERIMENTS USING URANIUM AND PLUTONIUM IN SOLUTIONS (900 TESTS), COMPACTED POWDER (300), AND METALLIC FORMS (500). ALL 1,700 CRITICALITY ASSEMBLIES WERE CONTROLLED FROM THIS PANEL. - Rocky Flats Plant, Critical Mass Laboratory, Intersection of Central Avenue & 86 Drive, Golden, Jefferson County, CO

  6. 12. DETAIL OF WEST END OF CENTRAL ATLAS CONTROL CONSOLE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. DETAIL OF WEST END OF CENTRAL ATLAS CONTROL CONSOLE IN SLC-3W CONTROL ROOM SHOWING LAUNCH CONDUCTOR AND ASSISTANT LAUNCH CONDUCTOR PANELS - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  7. 13. DETAIL OF CENTER OF CENTRAL CONTROL CONSOLE IN SLC3W ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. DETAIL OF CENTER OF CENTRAL CONTROL CONSOLE IN SLC-3W CONTROL ROOM SHOWING USAF LAUNCH CONTROLLER AND ASSISTANT USAF LAUNCH CONTROLLER PANELS. CONSOLES AND CHAIRS NEAR NORTH WALL IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  8. 66. DETAIL OF LAUNCH CONDUCTOR AND ASSISTANT LAUNCH CONDUCTOR PANELS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    66. DETAIL OF LAUNCH CONDUCTOR AND ASSISTANT LAUNCH CONDUCTOR PANELS IN CONSOLE LOCATED CENTRALLY IN SLC-3E CONTROL ROOM. FROM LEFT TO RIGHT IN BACKGROUND: LAUNCH OPERATOR, LAUNCH ANALYST, AND FACILITIES PANELS. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  9. Robust Power Management Control for Stand-Alone Hybrid Power Generation System

    NASA Astrophysics Data System (ADS)

    Kamal, Elkhatib; Adouane, Lounis; Aitouche, Abdel; Mohammed, Walaa

    2017-01-01

    This paper presents a new robust fuzzy control of energy management strategy for the stand-alone hybrid power systems. It consists of two levels named centralized fuzzy supervisory control which generates the power references for each decentralized robust fuzzy control. Hybrid power systems comprises: a photovoltaic panel and wind turbine as renewable sources, a micro turbine generator and a battery storage system. The proposed control strategy is able to satisfy the load requirements based on a fuzzy supervisor controller and manage power flows between the different energy sources and the storage unit by respecting the state of charge and the variation of wind speed and irradiance. Centralized controller is designed based on If-Then fuzzy rules to manage and optimize the hybrid power system production by generating the reference power for photovoltaic panel and wind turbine. Decentralized controller is based on the Takagi-Sugeno fuzzy model and permits us to stabilize each photovoltaic panel and wind turbine in presence of disturbances and parametric uncertainties and to optimize the tracking reference which is given by the centralized controller level. The sufficient conditions stability are formulated in the format of linear matrix inequalities using the Lyapunov stability theory. The effectiveness of the proposed Strategy is finally demonstrated through a SAHPS (stand-alone hybrid power systems) to illustrate the effectiveness of the overall proposed method.

  10. 9. View southeast corner of perimeter acquisition radar power plant ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. View southeast corner of perimeter acquisition radar power plant room #214, control room; showing central monitoring station console in foreground. Well and booster control panel in left background and electric power management panel on far right - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Power Plant, In Limited Access Area, Southwest of PARB at end of Service Road B, Nekoma, Cavalier County, ND

  11. Evaluation of the long-term efficacy of K-Othrine® PolyZone on three surfaces against laboratory reared Anopheles gambiae in semi-field conditions.

    PubMed

    Dunford, James C; Estep, Alden S; Waits, Christy M; Richardson, Alec G; Hoel, David F; Horn, Karin; Walker, Todd W; Blersch, Jessika S; Kerce, Jerry D; Wirtz, Robert A

    2018-02-23

    In this semi-field study, a new polymer-enhanced deltamethrin formulation, K-Othrine ® PolyZone, was compared to a standard deltamethrin product for residual activity against a susceptible strain of laboratory-reared Anopheles gambiae using standard WHO cone bioassays. Residual insecticide efficacy was recorded after exposure to metal, cement and wood panels maintained in experimental huts in sub-tropical environmental conditions in north central Florida, USA, and panels stored in a climate controlled chamber located at the Centers for Disease Control and Prevention, Georgia, USA. K-Othrine ® PolyZone demonstrated 100% control on metal and cement panels 1 year post application and > 80% control on wood panels up to 6 mo. The new formulation should be considered for use in indoor residual spray programmes requiring long-term control of malaria vectors.

  12. Law Panel in action.

    PubMed

    Odulana, J

    In September 1976 the Africa Regional Council (ARC) of IPPF created a Law Panel to 1) advise the ARC on the emphasis of laws and parenthood programs in the region, 2) investigate legal obstacles to family planning and ways of removing them, 3) institute a monitoring service on laws and court decisions affecting planned parenthood, and 4) prepare a list of lawyers and legal reformers by country. The panel has 1) recommended adoption of an IPPF Central Medical Committee and Central Law Panel statement on sterilization, adolescent fertility control, and the use of medical and auxiliary personnel in family planning services with guidelines for Africa; 2) appointed National Legal Correspondents to carry on the monitoring service mentioned above in 18 countries; and 3) discussed solutions to problems in delivering family planning services with family planning associations in Tanzania, Zambia, Mauritius, Madagascar, and Kenya. Laws governing family planning education and services, marriage, divorce, and maternity benefits in these countries are summarized. In 1978 the panel will hold 2 workshops on law and the status of women.

  13. 75 FR 38945 - Airworthiness Directives; The Boeing Company Model 777-200 and -300 Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ..., 2006. The service bulletin describes procedures for installing new operational software in the cabin... loading the new cabin services system central storage device software and CSCP OPS into the MMC. FAA's... cabin services system central storage device software and cabin system control panel operational...

  14. 1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. VIEW OF A PORTION OF THE HYDRIDE PROCESSING LABORATORY. OPERATIONS IN THE GLOVE BOX IN THE BACKGROUND OF THE PHOTOGRAPH INCLUDED HYDRIDING OF PLUTONIUM AND HYDRIDE SEPARATION. IN THE FOREGROUND, THE VACUUM MONITOR CONTROL PANEL MEASURED TEMPERATURES WITHIN THE GLOVEBOX. THE CENTER CONTROL PANEL REGULATED THE FURNACE INSIDE THE GLOVE BOX USED IN THE HYDRIDING PROCESSES. THIS EQUIPMENT WAS ESSENTIAL TO THE HYDRIDING PROCESS, AS WELL AS OTHER GLOVE BOX OPERATIONS. - Rocky Flats Plant, Plutonium Laboratory, North-central section of industrial area at 79 Drive, Golden, Jefferson County, CO

  15. 2. CLOSEUP OF THE ORNAMENTAL LIGHTS, THE CENTRAL BIFOLD DOORS, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. CLOSEUP OF THE ORNAMENTAL LIGHTS, THE CENTRAL BIFOLD DOORS, AND THE EXAGGERATED TRIGLYTHS ABOVE THE DOOR, LOOKING WEST. NOTE THE PERSONNEL DOOR COMPRISED OF THE BOTTOM THREE PANELS IN THE LEFT BIFOLD DOOR. - Wyoming Valley Flood Control System, Woodward Pumping Station, East of Toby Creek crossing by Erie-Lackawanna Railroad, Edwardsville, Luzerne County, PA

  16. Help at Hand

    ERIC Educational Resources Information Center

    Demski, Jennifer

    2009-01-01

    This article describes how centralized presentation control systems enable IT support staff to monitor equipment and assist end users more efficiently. At Temple University, 70 percent of the classrooms are equipped with an AMX touch panel, linked via a Netlink controller to an in-classroom computer, projector, DVD/VCR player, and speakers. The…

  17. Space shuttle heat pipe thermal control systems

    NASA Technical Reports Server (NTRS)

    Alario, J.

    1973-01-01

    Heat pipe (HP) thermal control systems designed for possible space shuttle applications were built and tested under this program. They are: (1) a HP augmented cold rail, (2) a HP/phase change material (PCM) modular heat sink and (3) a HP radiating panel for compartment temperature control. The HP augmented cold rail is similar to a standard two-passage fluid cold rail except that it contains an integral, centrally located HP throughout its length. The central HP core helps to increase the local power density capability by spreading concentrated heat inputs over the entire rail. The HP/PCM modular heat sink system consists of a diode HP connected in series to a standard HP that has a PCM canister attached to its mid-section. It is designed to connect a heat source to a structural heat sink during normal operation, and to automatically decouple from it and sink to the PCM whenever structural temperatures are too high. The HP radiating panel is designed to conductively couple the panel feeder HPs directly to a fluid line that serves as a source of waste heat. It is a simple strap-on type of system that requires no internal or external line modifications to distribute the heat to a large radiating area.

  18. Wisdom Appliance Control System

    NASA Astrophysics Data System (ADS)

    Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia

    2017-07-01

    Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.

  19. Optimal CV-22 Centralized Intermediate Repair Facility Locations and Parts Repair

    DTIC Science & Technology

    2009-06-01

    and Reorder Point for TEWS ............................ 36 Table 8. Excel Model for Safety Stock and Reorder Point for FADEC ...Digital Engine Control ( FADEC ) Main Wheel Assembly Blade Fold System Landing Gear Control Panel Drive System Interface Unit Main Landing Gear...Radar 4 Forward Looking Infrared System (FLIR) 4 Tactical Electronic Warfare System (TEWS) 1 Full Authority Digital Engine Control ( FADEC ) 2 Blade

  20. Development status of the PDC-1 Parabolic Dish Concentrator

    NASA Technical Reports Server (NTRS)

    Thostesen, T.; Soczak, I. F.; Pons, R. L.

    1982-01-01

    The status of development of the 12 m diameter parabolic dish concentrator which is planned for use with the Small Community Solar Thermal Power System. The PDC-1 unit features the use of plastic reflector film bonded to structural plastic gores supported by front-bracing steel ribs. An elevation-over-azimuth mount arrangement is employed, with a conventional wheel-and-track arrangement; outboard trunnions permit the dish to be stored in the face down position, with the added advantage of easy access to the power conversion assembly. The control system is comprised of a central computer (LSI 1123), a manual control panel, a concentrator control unit, two motor controllers, a Sun sensor, and two angular position resolvers. The system is designed for the simultaneous control of several concentrators. The optical testing of reflective panels is described.

  1. 15. Credit JTL: Detail, oblique view of central panel point ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Credit JTL: Detail, oblique view of central panel point connection at top chord; note recess in chord bar to right of joint, and missing third (central) vertical tie rod - Reading-Halls Station Bridge, U.S. Route 220, spanning railroad near Halls Station, Muncy, Lycoming County, PA

  2. 24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. INTERIOR OF CENTRAL ROOM. BASE POWER PANEL VISIBLE ON RIGHT WALL OF HALLWAY. - Chollas Heights Naval Radio Transmitting Facility, Transmitter Building, 6410 Zero Road, San Diego, San Diego County, CA

  3. Decentralized Control of Sound Radiation from an Aircraft-Style Panel Using Iterative Loop Recovery

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H.; Cabell, Randolph H.; Fuller, Chris R.

    2008-01-01

    A decentralized LQG-based control strategy is designed to reduce low-frequency sound transmission through periodically stiffened panels. While modern control strategies have been used to reduce sound radiation from relatively simple structural acoustic systems, significant implementation issues have to be addressed before these control strategies can be extended to large systems such as the fuselage of an aircraft. For instance, centralized approaches typically require a high level of connectivity and are computationally intensive, while decentralized strategies face stability problems caused by the unmodeled interaction between neighboring control units. Since accurate uncertainty bounds are not known a priori, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is validated using real-time control experiments performed on a built-up aluminum test structure representative of the fuselage of an aircraft. Experiments demonstrate that the iterative approach is capable of achieving 12 dB peak reductions and a 3.6 dB integrated reduction in radiated sound power from the stiffened panel.

  4. Building Automation Systems.

    ERIC Educational Resources Information Center

    Honeywell, Inc., Minneapolis, Minn.

    A number of different automation systems for use in monitoring and controlling building equipment are described in this brochure. The system functions include--(1) collection of information, (2) processing and display of data at a central panel, and (3) taking corrective action by sounding alarms, making adjustments, or automatically starting and…

  5. Potential Clinical Impact of The Filmarray Meningitis Encephalitis Panel In Children With Suspected Central Nervous System Infections

    PubMed Central

    Messacar, Kevin; Breazeale, Garrett; Robinson, Christine C.; Dominguez, Samuel R.

    2016-01-01

    The FilmArray Meningitis Encephalitis Panel, a multiplex PCR for testing of cerebrospinal fluid, was compared to conventional diagnostic methods in children with suspected central nervous system infections. The panel had comparable diagnostic yield (96% agreement) and improved time-to-diagnosis by 10.3 hours with potential for more judicious antimicrobial use, particularly acyclovir. PMID:27342782

  6. 77 FR 4047 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-26

    ... announced below concerns Epidemiology, Prevention and Treatment of Influenza and Other Respiratory... Diseases in Vietnam, IP12-002, The Incidence of Community Associated Influenza and Other Respiratory... Respiratory Infections in Panama and Central America Region, IP12-006, initial review. In accordance with...

  7. Planar optical waveguides for optical panel having gradient refractive index core

    DOEpatents

    Veligdan, James T.

    2001-01-01

    An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.

  8. Planar optical waveguides for optical panel having gradient refractive index core

    DOEpatents

    Veligdan, James T.

    2004-08-24

    An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.

  9. Central Control Room in the Engine Research Building

    NASA Image and Video Library

    1968-11-21

    Operators in the Engine Research Building’s Central Control Room at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The massive 4.25-acre Engine Research Building contains dozens of test cells, test stands, and altitude chambers. A powerful a collection of compressors and exhausters located in the central portion of the basement provides process air and exhaust for these test areas. This system is connected to similar process air systems in the laboratory’s other large test facilities. The Central Control Room coordinates this activity and communicates with the local utilities. The panels on the wall contain schematics with indicator lights and instrumentation for the atmospheric exhaust, altitude exhaust, refrigerated air, and process air systems. The process air equipment included twelve exhausters, four compressors, refrigeration system, cooling water, and an exhaust system. The operators in the control room kept in contact with engineers running the process air system and those conducting the tests in the test cells. The operators also coordinated with the local power companies to make sure enough electricity was available to operate the powerful compressors and exhausters.

  10. 1977 Florida Statewide Conference on Institutional Research. The Shift in Decision Making Responsibilities: Institutional Research Response.

    ERIC Educational Resources Information Center

    Strenglein, Denise, Ed.

    Centralized control of budgets and programs, a growing consumerism among students, and collective bargaining are among the issues addressed in a Florida statewide conference on institutional research. papers and reports include: the keynote address; a legislative workshop; a collective bargaining panel; The New College Story as Told by 103 Alumni…

  11. Engine Research Building’s Central Control Room

    NASA Image and Video Library

    1948-07-21

    Operators in the Engine Research Building’s Central Control Room at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The massive 4.25-acre Engine Research Building contains dozens of test cells, test stands, and altitude chambers. A powerful collection of compressors and exhausters located in the central portion of the basement provided process air and exhaust for these test areas. This system is connected to similar process air systems in the laboratory’s other large test facilities. The Central Control Room coordinates this activity and communicates with the local utilities. This photograph was taken just after a major upgrade to the control room in 1948. The panels on the wall contain rudimentary floor plans of the different Engine Research Building sections with indicator lights and instrumentation for each test cell. The process air equipment included 12 exhausters, four compressors, a refrigeration system, cooling water, and an exhaust system. The operators in the control room kept in contact with engineers running the process air system and those conducting the tests in the test cells. The operators also coordinated with the local power companies to make sure enough electricity was available to operate the powerful compressors and exhausters.

  12. Evaluation of first-draw whole blood, point-of-care cardiac markers in the context of the universal definition of myocardial infarction: a comparison of a multimarker panel to troponin alone and to testing in the central laboratory.

    PubMed

    Lee-Lewandrowski, Elizabeth; Januzzi, James L; Grisson, Ricky; Mohammed, Asim A; Lewandrowski, Grant; Lewandrowski, Kent

    2011-04-01

    Previous studies evaluating point-of-care testing (POCT) for cardiac biomarkers did not use current recommendations for troponin cutoff values or recognize the recent universal definition of acute myocardial infarction. Traditionally, achieving optimal sensitivity for the detection of myocardial injury on initial presentation required combining cardiac troponin and/or creatine kinase isoenzyme MB with an early marker, usually myoglobin. In recent years, the performance of central laboratory combining cardiac troponin assays has improved significantly, potentially obviating the need for a multimarker panel to achieve optimum sensitivity. To compare 2 commonly used POCT strategies to a fourth generation, central laboratory cardiac troponin T assay on first-draw specimens from patients being evaluated for acute myocardial infarction in the emergency department. The 2 strategies included a traditional POCT multimarker panel and a newer POCT method using cardiac troponin I alone. Blood specimens from 204 patients presenting to the emergency department with signs and/or symptoms of myocardial ischemia were measured on the 2 POCT systems and by a central laboratory method. The diagnosis for each patient was determined by retrospective chart review. The cardiac troponin T assasy alone was more sensitive for acute myocardial infarction than the multimarker POCT panel with equal or better specificity. When compared with a POCT troponin I, the cardiac troponin T was also more sensitive, but this difference was not significant. The POCT troponin I alone also had the same sensitivity as the multimarker panel. Testing for combining cardiac troponin alone using newer, commercially available, central laboratory or POCT assays performed with equal or greater sensitivity to acute myocardial infarction as the older, traditional, multimarker panel. In the near future, high-sensitivity, central laboratory troponins will be available for routine clinical use. As a result, the quality gap between central laboratories and older POCT methods will continue to widen, unless the performance of the POCT methods is improved.

  13. 12. Examples of the elaborate and plain pressedsteel ceiling panels, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Examples of the elaborate and plain pressed-steel ceiling panels, here removed to the exterior of the building for photographing. A segment of the cornice has been placed above the larger panel. The panel on the left is comprised of four square components; the panel on the right is a single piece. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  14. Artist: Rick Guidice Space Colonization - Bernal Sphere - The residential area is in the central

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Artist: Rick Guidice Space Colonization - Bernal Sphere - The residential area is in the central sphere. Farming regions are in the 'tires.' Mirrors reflect sunlight into the habitat and farms. The large flat panels radiate away extra heat into space, and panels of solar cells provide electricity. Factories and docks for spaceships are at either end of the long central tube. (NOTE: art printed in Book 'Space Colony - Frontier of the 21st Century by Franklyn M. Branley)

  15. Interaction Metrics for Feedback Control of Sound Radiation from Stiffened Panels

    NASA Technical Reports Server (NTRS)

    Cabell, Randolph H.; Cox, David E.; Gibbs, Gary P.

    2003-01-01

    Interaction metrics developed for the process control industry are used to evaluate decentralized control of sound radiation from bays on an aircraft fuselage. The metrics are applied to experimentally measured frequency response data from a model of an aircraft fuselage. The purpose is to understand how coupling between multiple bays of the fuselage can destabilize or limit the performance of a decentralized active noise control system. The metrics quantitatively verify observations from a previous experiment, in which decentralized controllers performed worse than centralized controllers. The metrics do not appear to be useful for explaining control spillover which was observed in a previous experiment.

  16. Analysis of stresses in finite anisotropic panels with centrally located cutouts

    NASA Technical Reports Server (NTRS)

    Britt, Vicki O.

    1992-01-01

    A method for analyzing biaxial- and shear-loaded anisotropic rectangular panels with centrally located circular and elliptical cutouts is presented in the present paper. The method is based on Lekhnitskii's complex variable equations of plane elastostatics combined with a boundary collocation method and a Laurent series approximation. Results are presented for anisotropic panels with elliptical cutouts and subjected to combined shear and compression loading. The effects on the stress field of panel aspect ratio, anisotropy, cutout size, and cutout orientation are addressed. Angle-ply laminates, unidirectional off-axis laminates, and ((+ or - 45/0/90)(sub 3))s, ((+ or - 45/0(sub 2))(sub 3))s, and ((+ or - 45/90(sub 2))(sub 3))s laminates are examined.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  18. Buckling and postbuckling of composite panels with cutouts subjected to combined edge shear and temperature change

    NASA Technical Reports Server (NTRS)

    Noor, Ahmed K.; Kim, Yong H.

    1995-01-01

    The results of a detailed study of the buckling and postbuckling responses of composite panels with central circular cutouts are presented. The panels are subjected to combined edge shear and temperature change. The panels are discretized by using a two-field degenerate solid element with each of the displacement components having a linear variation throughout the thickness of the panel. The fundamental unknowns consist of the average mechanical strains through the thickness and the displacement components. The effects of geometric nonlinearities and laminated anisotropic material behavior are included. The stability boundary, postbuckling response and the hierarchical sensitivity coefficients are evaluated. The hierarchical sensitivity coefficients measure the sensitivity of the buckling and postbuckling responses to variations in the panel stiffnesses, and the material properties of both the individual layers and the constituents (fibers and matrix). Numerical results are presented for composite panels with central circular cutouts subjected to combined edge shear and temperature change, showing the effects of variations in the hole diameter, laminate stacking sequence and fiber orientation, on the stability boundary and postbuckling response and their sensitivity to changes in the various panel parameters.

  19. Control system design for the large space systems technology reference platform

    NASA Technical Reports Server (NTRS)

    Edmunds, R. S.

    1982-01-01

    Structural models and classical frequency domain control system designs were developed for the large space systems technology (LSST) reference platform which consists of a central bus structure, solar panels, and platform arms on which a variety of experiments may be mounted. It is shown that operation of multiple independently articulated payloads on a single platform presents major problems when subarc second pointing stability is required. Experiment compatibility will be an important operational consideration for systems of this type.

  20. Information management system breadboard data acquisition and control system.

    NASA Technical Reports Server (NTRS)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  1. Performance of different mono- and multiplex nucleic acid amplification tests on a multipathogen external quality assessment panel.

    PubMed

    Loens, K; van Loon, A M; Coenjaerts, F; van Aarle, Y; Goossens, H; Wallace, P; Claas, E J C; Ieven, M

    2012-03-01

    An external quality assessment (EQA) panel consisting of a total of 48 samples in bronchoalveolar lavage (BAL) fluid or transport medium was prepared in collaboration with Quality Control for Molecular Diagnostics (QCMD) (www.qcmd.org). The panel was used to assess the proficiency of the three laboratories that would be responsible for examining the 6,000 samples to be collected in the GRACE Network of Excellence (www.grace-lrti.org). The main objective was to decide on the best-performing testing approach for the detection of influenza viruses A and B, parainfluenza virus types 1 to 3, respiratory syncytial virus (RSV), human metapneumovirus, coronavirus, rhinovirus, adenovirus, Chlamydophila pneumoniae, Mycoplasma pneumoniae, and Legionella pneumophila by nucleic acid amplification techniques (NAATs). Two approaches were chosen: (i) laboratories testing samples using their in-house procedures for extraction and amplification and (ii) laboratories using their in-house amplification procedures on centrally extracted samples. Furthermore, three commercially available multiplex NAAT tests-the ResPlex (Qiagen GmbH, Hilden, Germany), RespiFinder plus (PathoFinder, Maastricht, The Netherlands), and RespiFinder Smart 21 (PathoFinder) tests-were evaluated by examination of the same EQA panel by the manufacturer. No large differences among the 3 laboratories were noticed when the performances of the assays developed in-house in combination with the in-house extraction procedures were compared. Also, the extraction procedure (central versus local) had little effect on performance. However, large differences in amplification efficacy were found between the commercially available tests; acceptable results were obtained by using the PathoFinder assays.

  2. 75 FR 80790 - Proposed Information Collection; Comment Request; Survey of Income and Program Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ..., which is a household-based survey designed as a continuous series of national panels. New panels are... DEPARTMENT OF COMMERCE U.S. Census Bureau Proposed Information Collection; Comment Request; Survey... at 4-month intervals or ``waves'' over the life of the panel. The survey is molded around a central...

  3. Shear and compression buckling analysis for anisotropic panels with centrally located elliptical cutouts

    NASA Technical Reports Server (NTRS)

    Britt, V. O.

    1993-01-01

    An approximate analysis for buckling of biaxial- and shear-loaded anisotropic panels with centrally located elliptical cutouts is presented in the present paper. The analysis is composed of two parts, a prebuckling analysis and a buckling analysis. The prebuckling solution is determined using Lekhnitskii's complex variable equations of plane elastostatics combined with a Laurent series approximation and a boundary collocation method. The buckling solution is obtained using the principle of minimum potential energy. A by-product of the minimum potential energy equation is an integral equation which is solved using Gaussian quadrature. Comparisons with documented experimental results and finite element analyses indicate that the approximate analysis accurately predicts the buckling loads of square biaxial- and shear-loaded panels having elliptical cutouts with major axes up to sixty percent of the panel width. Results of a parametric study are presented for shear- and compression-loaded rectangular anisotropic panels with elliptical cutouts. The effects of panel aspect ratio, cutout shape, cutout size, cutout orientation, laminate anisotropy, and combined loading on the buckling load are examined.

  4. 31. View of mezzanine floor level in transmitter building no. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. View of mezzanine floor level in transmitter building no. 102 showing various electronic central indicator panel to control building air conditioning, steam pressure, supply temperature, discharge temperature, supply pressure, transformer vault status, and radome conditioning system. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  5. Project PARAS: Phased array radio astronomy from space

    NASA Technical Reports Server (NTRS)

    Nuss, Kenneth; Hoffmann, Christopher; Dungan, Michael; Madden, Michael; Bendakhlia, Monia

    1992-01-01

    An orbiting radio telescope is proposed which, when operated in a very long baseline interferometry (VLBI) scheme, would allow higher than currently available angular resolution and dynamic range in the maps and the ability to observe rapidly changing astronomical sources. Using passive phased array technology, the proposed design consists of 656 hexagonal modules forming a 150-m diameter antenna dish. Each observatory module is largely autonomous, having its own photovoltaic power supply and low-noise receiver and processor for phase shifting. The signals received by the modules are channeled via fiber optics to the central control computer in the central bus module. After processing and multiplexing, the data are transmitted to telemetry stations on the ground. The truss frame supporting each observatory panel is a novel hybrid structure consisting of a bottom graphite/epoxy tubular triangle and rigidized inflatable Kevlar tubes connecting the top observatory panel and the bottom triangle. Attitude control and station keeping functions will be performed by a system of momentum wheels in the bus and four propulsion modules located at the compass points on the periphery of the observatory dish. Each propulsion module has four monopropellant thrusters and four hydrazine arcjets, the latter supported by either a photovoltaic array or a radioisotope thermoelectric generator. The total mass of the spacecraft is about 20,500 kg.

  6. 78 FR 104 - Advisory Committees; Tentative Schedule of Meetings for 2013

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-02

    ... Date(s), if needed, to be Committee. determined. Peripheral and Central Nervous System May 22. Drugs... be Devices Panel. determined. Circulatory System Devices Panel....... May 17, May 24, June 27...

  7. ARC-1976-AC76-0965

    NASA Image and Video Library

    1976-06-11

    Artist: Rick Guidice Space Colonization - Bernal Sphere - The residential area is in the central sphere. Farming regions are in the 'tires.' Mirrors reflect sunlight into the habitat and farms. The large flat panels radiate away extra heat into space, and panels of solar cells provide electricity. Factories and docks for spaceships are at either end of the long central tube. (NOTE: art printed in Book 'Space Colony - Frontier of the 21st Century by Franklyn M. Branley)

  8. 65. DETAIL OF ASSISTANT LAUNCH CONTROLLER AND LAUNCH CONTROLLER PANELS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    65. DETAIL OF ASSISTANT LAUNCH CONTROLLER AND LAUNCH CONTROLLER PANELS LOCATED NEAR CENTER OF SLC-3E CONTROL ROOM. NOTE 30-CHANNEL COMMUNICATIONS PANELS. PAYLOAD ENVIRONMENTAL CONTROL AND MONITORING PANELS (LEFT) AND LAUNCH OPERATORS PANEL (RIGHT) IN BACKGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  9. 75 FR 9416 - Advisory Committee Information Hotline

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... Drugs Advisory Committee 3014512542 Peripheral and Central Nervous System Drugs Advisory Committee... Devices Panel 3014512624 Circulatory System Devices Panel 3014512625 Clinical Chemistry and Clinical... about any particular advisory committee meeting, this system will provide interested parties with timely...

  10. Event centrality prospectively predicts PTSD symptoms.

    PubMed

    Boals, Adriel; Ruggero, Camilo

    2016-09-01

    Recent evidence suggests that event centrality has a prominent association with post-traumatic stress disorder (PTSD) symptoms. However, evidence for this notion thus far has been mostly correlational. We report two studies that prospectively examined the relationship between event centrality and PTSD symptoms. Study 1 METHODS: Participants (N = 1438) reported their most stressful event ("prior event"), along with event centrality, PTSD symptoms, and neuroticism. At Time 2 participants reported their most stressful event since Time 1 ("critical event"), along with measures of event centrality and PTSD symptoms. Study 1 RESULTS: Event centrality for the critical event predicted PTSD symptoms, after controlling for event centrality and PTSD symptoms of the prior event and neuroticism. Study In the second study (N = 161) we examined changes in event centrality and PTSD symptoms over a month. Study 2 RESULTS: Using a cross-lagged panel design, results revealed event centrality at Time 1 significantly predicted PTSD symptoms at Time 2, but the reverse was not significant. In two studies, a prospective association between event centrality and PTSD symptoms, but not the reverse, emerged. This evidence implicates event centrality in the pathogenesis and/or maintenance of PTSD symptoms.

  11. 11. An abandoned electrical system was found under the pressedsteel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. An abandoned electrical system was found under the pressed-steel ceiling. For some undetermined reason the pattern of the ceiling panels has 'photographed' onto the cardboard substrate. Two different panel designs were utilized in a checkerboard pattern. One panel of each design remains in place. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  12. CubeSat Form Factor Thermal Control Louvers

    NASA Technical Reports Server (NTRS)

    Evans, Allison L. (Inventor)

    2018-01-01

    Thermal control louvers for CubeSats or small spacecraft may include a plurality of springs attached to a back panel of the thermal control louvers. The thermal control louvers may also include a front panel, which includes at least two end panels interlocked with one or more middle panels. The front panel may secure the springs, shafts, and flaps to the back panel.

  13. Rotating flexible drag mill

    DOEpatents

    Pepper, W.B.

    1984-05-09

    A rotating parachute for decelerating objects travelling through atmosphere at subsonic or supersonic deployment speeds includes a circular canopy having a plurality of circumferentially arranged flexible panels projecting radially from a solid central disk. A slot extends radially between adjacent panels to the outer periphery of the canopy. Upon deployment, the solid disk diverts air radially to rapidly inflate the panels into a position of maximum diameter. Air impinging on the panels adjacent the panel slots rotates the parachute during its descent. Centrifugal force flattens the canopy into a constant maximum diameter during terminal descent for maximum drag and deceleration.

  14. Active structural acoustic control of noise transmission through double panel systems

    NASA Astrophysics Data System (ADS)

    Carneal, James P.; Fuller, Chris R.

    1995-04-01

    A preliminary parametric study of active control of sound transmission through double panel systems has been experimentally performed. The technique used is the active structural acoustic control (ASAC) approach where control inputs, in the form of piezoelectric actuators, were applied to the structure while the radiated pressure field was minimized. Results indicate the application of control inputs to the radiating panel resulted in greater transmission loss due to its direct effect on the nature of the structural-acoustic coupling between the radiating panel and the receiving chamber. Increased control performance was seen in a double panel system consisting of a stiffer radiating panel with a lower modal density. As expected, more effective control of a radiating panel excited on-resonance is achieved over one excited off-resonance. In general, the results validate the ASAC approach for double panel systems and demonstrate that it is possible to take advantage of double panel behavior to enhance control performance, although it is clear that further research must be done to understand the physics involved.

  15. Central Nervous System Cancers, Version 1.2015.

    PubMed

    Nabors, Louis Burt; Portnow, Jana; Ammirati, Mario; Baehring, Joachim; Brem, Henry; Brown, Paul; Butowski, Nicholas; Chamberlain, Marc C; Fenstermaker, Robert A; Friedman, Allan; Gilbert, Mark R; Hattangadi-Gluth, Jona; Holdhoff, Matthias; Junck, Larry; Kaley, Thomas; Lawson, Ronald; Loeffler, Jay S; Lovely, Mary P; Moots, Paul L; Mrugala, Maciej M; Newton, Herbert B; Parney, Ian; Raizer, Jeffrey J; Recht, Lawrence; Shonka, Nicole; Shrieve, Dennis C; Sills, Allen K; Swinnen, Lode J; Tran, David; Tran, Nam; Vrionis, Frank D; Weiss, Stephanie; Wen, Patrick Yung; McMillian, Nicole; Engh, Anita M

    2015-10-01

    The NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines) for Central Nervous System (CNS) Cancers provide interdisciplinary recommendations for managing adult CNS cancers. Primary and metastatic brain tumors are a heterogeneous group of neoplasms with varied outcomes and management strategies. These NCCN Guidelines Insights summarize the NCCN CNS Cancers Panel's discussion and highlight notable changes in the 2015 update. This article outlines the data and provides insight into panel decisions regarding adjuvant radiation and chemotherapy treatment options for high-risk newly diagnosed low-grade gliomas and glioblastomas. Additionally, it describes the panel's assessment of new data and the ongoing debate regarding the use of alternating electric field therapy for high-grade gliomas. Copyright © 2015 by the National Comprehensive Cancer Network.

  16. 12. DETAIL, DECORATIVE PANEL, HEAT EXCHANGER (CROPPED PRINT FROM 21/4 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. DETAIL, DECORATIVE PANEL, HEAT EXCHANGER (CROPPED PRINT FROM 2-1/4 x 2-3/4 NEGATIVE) - U.S. General Services Administration, Central Heating Plant, C & D Streets between Twelfth & Thirteenth Streets Southwest, Washington, District of Columbia, DC

  17. SCD 02 thermal design

    NASA Technical Reports Server (NTRS)

    Cardoso, Humberto Pontes

    1990-01-01

    The Satelite de Coleta de Dados (SCD) 02 (Data Collection Satellite) has the following characteristics: 115 kg weight, octagonal prism shape, 1 m diameter, and 0.67 m height. Its specified orbit is nearly circular, 700 km altitude, is inclined 25 deg with respect to the equator line, and has 100 min period. The electric power is supplied by eight solar panels installed on the lateral sides of the satellite. The equipment is located on the central (both faces) and lower (internal face) panels. The satellite is spin stabilized and its attitude control is such that during its lifetime, the solar aspect angle will vary between 80 and 100 deg with respect to its spin axis. Two critical cases were selected for thermal control design purposes: Hot case (maximum solar constant, solar aspect angle equal to 100 deg, minimum eclipse time and maximum internal heat dissipation); and a passive thermal design concept was achieved and the maximum and minimum equipment operating temperatures were obtained through a 109 node finite difference mathematical model.

  18. View southeast of main supervisory board showing panels 3 through ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of main supervisory board showing panels 3 through 11; panel 3 at far left contains meters for monitoring power in the system; panel 4 contains controls for controlling heaters to keep track twitches free of ice and snow; panels 5, 6, and 7 date to the 1935 installation and control the catenary in the area of the station yard. These work on 120 volts direct current; panel 8 contains circuit breakers (rupture switches) which control power to individual tracks in the station area; panels 9 and 10 house controls for the West Philadelphia sub-station; panel 11 controls sub-station 13 in South Wilmington Delaware and miscellaneous meters - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA

  19. Design of a modular digital computer system, CDRL no. D001, final design plan

    NASA Technical Reports Server (NTRS)

    Easton, R. A.

    1975-01-01

    The engineering breadboard implementation for the CDRL no. D001 modular digital computer system developed during design of the logic system was documented. This effort followed the architecture study completed and documented previously, and was intended to verify the concepts of a fault tolerant, automatically reconfigurable, modular version of the computer system conceived during the architecture study. The system has a microprogrammed 32 bit word length, general register architecture and an instruction set consisting of a subset of the IBM System 360 instruction set plus additional fault tolerance firmware. The following areas were covered: breadboard packaging, central control element, central processing element, memory, input/output processor, and maintenance/status panel and electronics.

  20. Comparison of various decentralised structural and cavity feedback control strategies for transmitted noise reduction through a double panel structure

    NASA Astrophysics Data System (ADS)

    Ho, Jen-Hsuan; Berkhoff, Arthur

    2014-03-01

    This paper compares various decentralised control strategies, including structural and acoustic actuator-sensor configuration designs, to reduce noise transmission through a double panel structure. The comparison is based on identical control stability indexes. The double panel structure consists of two panels with air in between and offers the advantages of low sound transmission at high frequencies, low heat transmission, and low weight. The double panel structure is widely used, such as in the aerospace and automotive industries. Nevertheless, the resonance of the cavity and the poor sound transmission loss at low frequencies limit the double panel's noise control performance. Applying active structural acoustic control to the panels or active noise control to the cavity has been discussed in many papers. In this paper, the resonances of the panels and the cavity are considered simultaneously to further reduce the transmitted noise through an existing double panel structure. A structural-acoustic coupled model is developed to investigate and compare various structural control and cavity control methods. Numerical analysis and real-time control results show that structural control should be applied to both panels. Three types of cavity control sources are presented and compared. The results indicate that the largest noise reduction is obtained with cavity control by loudspeakers modified to operate as incident pressure sources.

  1. 30 CFR 77.310 - Control panels.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Control panels. 77.310 Section 77.310 Mineral....310 Control panels. (a) All thermal dryer system control panels constructed after June 30, 1971 shall... each thermocouple, pressure tap, or other control or gaging instrument in the drying system shall be...

  2. 30 CFR 77.310 - Control panels.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Control panels. 77.310 Section 77.310 Mineral....310 Control panels. (a) All thermal dryer system control panels constructed after June 30, 1971 shall... each thermocouple, pressure tap, or other control or gaging instrument in the drying system shall be...

  3. 30 CFR 77.310 - Control panels.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Control panels. 77.310 Section 77.310 Mineral....310 Control panels. (a) All thermal dryer system control panels constructed after June 30, 1971 shall... each thermocouple, pressure tap, or other control or gaging instrument in the drying system shall be...

  4. Multicenter validation of cancer gene panel-based next-generation sequencing for translational research and molecular diagnostics.

    PubMed

    Hirsch, B; Endris, V; Lassmann, S; Weichert, W; Pfarr, N; Schirmacher, P; Kovaleva, V; Werner, M; Bonzheim, I; Fend, F; Sperveslage, J; Kaulich, K; Zacher, A; Reifenberger, G; Köhrer, K; Stepanow, S; Lerke, S; Mayr, T; Aust, D E; Baretton, G; Weidner, S; Jung, A; Kirchner, T; Hansmann, M L; Burbat, L; von der Wall, E; Dietel, M; Hummel, M

    2018-04-01

    The simultaneous detection of multiple somatic mutations in the context of molecular diagnostics of cancer is frequently performed by means of amplicon-based targeted next-generation sequencing (NGS). However, only few studies are available comparing multicenter testing of different NGS platforms and gene panels. Therefore, seven partner sites of the German Cancer Consortium (DKTK) performed a multicenter interlaboratory trial for targeted NGS using the same formalin-fixed, paraffin-embedded (FFPE) specimen of molecularly pre-characterized tumors (n = 15; each n = 5 cases of Breast, Lung, and Colon carcinoma) and a colorectal cancer cell line DNA dilution series. Detailed information regarding pre-characterized mutations was not disclosed to the partners. Commercially available and custom-designed cancer gene panels were used for library preparation and subsequent sequencing on several devices of two NGS different platforms. For every case, centrally extracted DNA and FFPE tissue sections for local processing were delivered to each partner site to be sequenced with the commercial gene panel and local bioinformatics. For cancer-specific panel-based sequencing, only centrally extracted DNA was analyzed at seven sequencing sites. Subsequently, local data were compiled and bioinformatics was performed centrally. We were able to demonstrate that all pre-characterized mutations were re-identified correctly, irrespective of NGS platform or gene panel used. However, locally processed FFPE tissue sections disclosed that the DNA extraction method can affect the detection of mutations with a trend in favor of magnetic bead-based DNA extraction methods. In conclusion, targeted NGS is a very robust method for simultaneous detection of various mutations in FFPE tissue specimens if certain pre-analytical conditions are carefully considered.

  5. 61. Upper panel in cornerpower panel lcpa lower panel in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. Upper panel in corner-power panel lcpa lower panel in corner-oxygen regeneration unit, at right-air conditioner control panel, on floor-bio-pack 45 for emergency breathing, looking northwest - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  6. 16. Detail of original wainscot in the dining room. The ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. Detail of original wainscot in the dining room. The wainscot panels are flat (not beveled) and are painted along the edge to simulate a raised (beveled) panel. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  7. An analytical and experimental investigation of active structural acoustic control of noise transmission through double panel systems

    NASA Astrophysics Data System (ADS)

    Carneal, James P.; Fuller, Chris R.

    2004-05-01

    An analytical and experimental investigation of active control of sound transmission through double panel systems has been performed. The technique used was active structural acoustic control (ASAC) where the control inputs, in the form of piezoelectric actuators, were applied to the structure while the radiating pressure field was minimized. Results verify earlier experimental investigations and indicate the application of control inputs to the radiating panel of the double panel system resulted in greater transmission loss (TL) due to its direct effect on the nature of the structural-acoustic (or radiation) coupling between the radiating panel and the receiving acoustic space. Increased control performance was seen in a double panel system consisting of a stiffer radiating panel due to its lower modal density and also as a result of better impedance matching between the piezoelectric actuator and the radiating plate. In general the results validate the ASAC approach for double panel systems, demonstrating that it is possible to take advantage of double panel system passive behavior to enhance control performance, and provide design guidelines.

  8. 30 CFR 77.310 - Control panels.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Control panels. 77.310 Section 77.310 Mineral....310 Control panels. (a) All thermal dryer system control panels constructed after June 30, 1971 shall... manner as to minimize vibration. (b) A schematic diagram containing legends which show the location of...

  9. 30 CFR 77.310 - Control panels.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Control panels. 77.310 Section 77.310 Mineral....310 Control panels. (a) All thermal dryer system control panels constructed after June 30, 1971 shall... manner as to minimize vibration. (b) A schematic diagram containing legends which show the location of...

  10. Work and Family in the United States: A Policy Initiative. A Report of the Family Policy Panel of the Economic Policy Council of UNA-USA.

    ERIC Educational Resources Information Center

    United Nations Association of the United States of America, New York, NY.

    As part of its world employment project, the Economic Policy Council of the United Nations Association of the United States formed the family policy panel to further examine the extent of ongoing changes affecting the family, the workplace, and the economy. In its work, the family policy panel concentrated on five issues considered central to the…

  11. Active control of turbulent boundary layer-induced sound transmission through the cavity-backed double panels

    NASA Astrophysics Data System (ADS)

    Caiazzo, A.; Alujević, N.; Pluymers, B.; Desmet, W.

    2018-05-01

    This paper presents a theoretical study of active control of turbulent boundary layer (TBL) induced sound transmission through the cavity-backed double panels. The aerodynamic model used is based on the Corcos wall pressure distribution. The structural-acoustic model encompasses a source panel (skin panel), coupled through an acoustic cavity to the radiating panel (trim panel). The radiating panel is backed by a larger acoustic enclosure (the back cavity). A feedback control unit is located inside the acoustic cavity between the two panels. It consists of a control force actuator and a sensor mounted at the actuator footprint on the radiating panel. The control actuator can react off the source panel. It is driven by an amplified velocity signal measured by the sensor. A fully coupled analytical structural-acoustic model is developed to study the effects of the active control on the sound transmission into the back cavity. The stability and performance of the active control system are firstly studied on a reduced order model. In the reduced order model only two fundamental modes of the fully coupled system are assumed. Secondly, a full order model is considered with a number of modes large enough to yield accurate simulation results up to 1000 Hz. It is shown that convincing reductions of the TBL-induced vibrations of the radiating panel and the sound pressure inside the back cavity can be expected. The reductions are more pronounced for a certain class of systems, which is characterised by the fundamental natural frequency of the skin panel larger than the fundamental natural frequency of the trim panel.

  12. Anger, Sadness and Fear in Response to Breaking Crime and Accident News Stories: How Emotions Influence Support for Alcohol-Control Public Policies via Concern about Risks

    PubMed Central

    Solloway, Tyler; Slater, Michael D.; Chung, Adrienne; Goodall, Catherine

    2015-01-01

    Prior research shows that discrete emotions, notably anger and fear, can explain effects of news articles on health and alcohol-control policy support. This study advances prior work by coding expressed emotional responses to messages (as opposed to directly manipulated emotions or forced responses), incorporating and controlling for central thoughts, including sadness (a particularly relevant response to tragic stories), and examining concern’s mediating role between emotion and policy support. An experiment with a national online adult panel had participants read one of 60 violent crime or accident news stories, each manipulated to mention or withhold alcohol’s causal contribution. Multi-group structural equation models suggest that stories not mentioning alcohol had a direct effect on policy support via fear and central thoughts, unmediated by concern. When alcohol was mentioned, sadness and anger affects alcohol-control support through concern. Findings help confirm that emotional responses are key in determining news story effects on public support of health policies. PMID:26491487

  13. Limit Theory for Panel Data Models with Cross Sectional Dependence and Sequential Exogeneity.

    PubMed

    Kuersteiner, Guido M; Prucha, Ingmar R

    2013-06-01

    The paper derives a general Central Limit Theorem (CLT) and asymptotic distributions for sample moments related to panel data models with large n . The results allow for the data to be cross sectionally dependent, while at the same time allowing the regressors to be only sequentially rather than strictly exogenous. The setup is sufficiently general to accommodate situations where cross sectional dependence stems from spatial interactions and/or from the presence of common factors. The latter leads to the need for random norming. The limit theorem for sample moments is derived by showing that the moment conditions can be recast such that a martingale difference array central limit theorem can be applied. We prove such a central limit theorem by first extending results for stable convergence in Hall and Hedye (1980) to non-nested martingale arrays relevant for our applications. We illustrate our result by establishing a generalized estimation theory for GMM estimators of a fixed effect panel model without imposing i.i.d. or strict exogeneity conditions. We also discuss a class of Maximum Likelihood (ML) estimators that can be analyzed using our CLT.

  14. Fabrication and installation of the Solar Two central receiver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litwin, R.Z.; Rogers, R.D.

    The heart of the Solar Two power plant is the molten salt central receiver that has been designed, fabricated, and installed over an 18 month schedule. During this time, the receiver system from Solar One was also completely disassembled and removed. The receiver tower structure, for the most part, was left intact because Solar Two was designed to fit this structure such that construction time and costs could be minimized. In order to meet this aggressive schedule, receiver panel fabrication required the parallel production of many components. The sequence for assembly of the four major receiver panel components (i.e., tubes,more » header assembly, strongback, and header oven covers) and key fabrication activities such as welding are described. Once the receiver panels were complete, their installation at the site was begun, and the order in which receiver system components were installed in the tower is described. The completion of the Solar Two receiver proved the fabricability of this important system. However, successful operation of the system at Solar Two is needed to demonstrate the technical feasibility of the molten salt central receiver concept.« less

  15. A New MPPT Control for Photovoltaic Panels by Instantaneous Maximum Power Point Tracking

    NASA Astrophysics Data System (ADS)

    Tokushima, Daiki; Uchida, Masato; Kanbei, Satoshi; Ishikawa, Hiroki; Naitoh, Haruo

    This paper presents a new maximum power point tracking control for photovoltaic (PV) panels. The control can be categorized into the Perturb and Observe (P & O) method. It utilizes instantaneous voltage ripples at PV panel output terminals caused by the switching of a chopper connected to the panel in order to identify the direction for the maximum power point (MPP). The tracking for the MPP is achieved by a feedback control of the average terminal voltage of the panel. Appropriate use of the instantaneous and the average values of the PV voltage for the separate purposes enables both the quick transient response and the good convergence with almost no ripples simultaneously. The tracking capability is verified experimentally with a 2.8 W PV panel under a controlled experimental setup. A numerical comparison with a conventional P & O confirms that the proposed control extracts much more power from the PV panel.

  16. 32 CFR 1907.02 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Defense Other Regulations Relating to National Defense CENTRAL INTELLIGENCE AGENCY CHALLENGES TO... means the United States Central Intelligence Agency acting through the CIA Information and Privacy... Agency Release Panel; (g) Information means any knowledge that can be communicated or documentary...

  17. 32 CFR 1907.02 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Defense Other Regulations Relating to National Defense CENTRAL INTELLIGENCE AGENCY CHALLENGES TO... means the United States Central Intelligence Agency acting through the CIA Information and Privacy... Agency Release Panel; (g) Information means any knowledge that can be communicated or documentary...

  18. 32 CFR 1907.02 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Defense Other Regulations Relating to National Defense CENTRAL INTELLIGENCE AGENCY CHALLENGES TO... means the United States Central Intelligence Agency acting through the CIA Information and Privacy... Agency Release Panel; (g) Information means any knowledge that can be communicated or documentary...

  19. Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium

    PubMed Central

    Finak, Greg; Langweiler, Marc; Jaimes, Maria; Malek, Mehrnoush; Taghiyar, Jafar; Korin, Yael; Raddassi, Khadir; Devine, Lesley; Obermoser, Gerlinde; Pekalski, Marcin L.; Pontikos, Nikolas; Diaz, Alain; Heck, Susanne; Villanova, Federica; Terrazzini, Nadia; Kern, Florian; Qian, Yu; Stanton, Rick; Wang, Kui; Brandes, Aaron; Ramey, John; Aghaeepour, Nima; Mosmann, Tim; Scheuermann, Richard H.; Reed, Elaine; Palucka, Karolina; Pascual, Virginia; Blomberg, Bonnie B.; Nestle, Frank; Nussenblatt, Robert B.; Brinkman, Ryan Remy; Gottardo, Raphael; Maecker, Holden; McCoy, J Philip

    2016-01-01

    Standardization of immunophenotyping requires careful attention to reagents, sample handling, instrument setup, and data analysis, and is essential for successful cross-study and cross-center comparison of data. Experts developed five standardized, eight-color panels for identification of major immune cell subsets in peripheral blood. These were produced as pre-configured, lyophilized, reagents in 96-well plates. We present the results of a coordinated analysis of samples across nine laboratories using these panels with standardized operating procedures (SOPs). Manual gating was performed by each site and by a central site. Automated gating algorithms were developed and tested by the FlowCAP consortium. Centralized manual gating can reduce cross-center variability, and we sought to determine whether automated methods could streamline and standardize the analysis. Within-site variability was low in all experiments, but cross-site variability was lower when central analysis was performed in comparison with site-specific analysis. It was also lower for clearly defined cell subsets than those based on dim markers and for rare populations. Automated gating was able to match the performance of central manual analysis for all tested panels, exhibiting little to no bias and comparable variability. Standardized staining, data collection, and automated gating can increase power, reduce variability, and streamline analysis for immunophenotyping. PMID:26861911

  20. 77 FR 2983 - Medicare, Medicaid, and Children's Health Insurance Programs; Meeting of the Advisory Panel on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-20

    ... order to promote an active, informed selection among such options.'' The Panel is also authorized by... Central Texas Council of Governments' Area Agency on Aging; Warren Jones, Executive Director, Mississippi... Authority; Sandy Markwood, Chief Executive Officer, National Association of Area Agencies on Aging; Miriam...

  1. 76 FR 10941 - Open Meeting of the Taxpayer Advocacy Panel Taxpayer Assistance Center Project Committee

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-28

    ... Project Committee will be conducted. The Taxpayer Advocacy Panel is soliciting public comments, ideas, and... Taxpayer Assistance Center Project Committee will be held Tuesday, April 26, 2011, at 2 p.m., Central Time... Taxpayer Assistance Center Project Committee AGENCY: Internal Revenue Service (IRS), Treasury. ACTION...

  2. 20. VIEW OF CONSOLE IN NORTHWEST CORNER OF SLC3W CONTROL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. VIEW OF CONSOLE IN NORTHWEST CORNER OF SLC-3W CONTROL ROOM. PANELS FROM LEFT TO RIGHT: OPERATIONS AND CHECKOUT (LABELED POWER CONTROL AND MONITOR PANEL); RANGE SAFETY (LABELED DESTRUCT SYSTEM CONTROL AND MONITOR PANEL); BATTERY CLOCK PANELS. PEDAL FOR FOOT CONTROL OF COMMUNICATIONS HEADSET AND HEADSET IN FOREGROUND. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. Deployable reflector structure

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin, Jr. (Inventor); Hoberman, Charles (Inventor)

    1993-01-01

    A deployable reflector structure is presented. The structure has a number of movable reflector panels pivotably supported on rigid arms. Several such arms are pivotably connected to a central structure. The arm can move in starburst fashion from a packaged stage, where all arms are vertical, to a deployed stage, where all arms are horizontal. All of the movable reflector panels are maintained at a predetermined angle to an axis of the reflector structure when the arms are pivoted. The reflector panels are stacked tightly on top of each other in the packaged state of the reflector structure. Simple mechanisms are used for avoiding interference between panels on different arms in the packaged stage and for fitting the movable panels together like tiles in the deployed stage.

  4. Public acceptance for centralized storage and repositories of low-level waste session (Panel)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lutz, H.R.

    1995-12-31

    Participants from various parts of the world will provide a summary of their particular country`s approach to low-level waste management and the cost of public acceptance for low-level waste management facilities. Participants will discuss the number, geographic location, and type of low-level waste repositories and centralized storage facilities located in their countries. Each will discuss the amount, distribution, and duration of funds to gain public acceptance of these facilities. Participants will provide an estimated $/meter for centralized storage facilities and repositories. The panel will include a brief discussion about the ethical aspects of public acceptance costs, approaches for negotiating acceptance,more » and lessons learned in each country. The audience is invited to participate in the discussion.« less

  5. Active noise control using a distributed mode flat panel loudspeaker.

    PubMed

    Zhu, H; Rajamani, R; Dudney, J; Stelson, K A

    2003-07-01

    A flat panel distributed mode loudspeaker (DML) has many advantages over traditional cone speakers in terms of its weight, size, and durability. However, its frequency response is uneven and complex, thus bringing its suitability for active noise control (ANC) under question. This paper presents experimental results demonstrating the effective use of panel DML speakers in an ANC application. Both feedback and feedforward control techniques are considered. Effective feedback control with a flat panel speaker could open up a whole range of new noise control applications and has many advantages over feedforward control. The paper develops a new control algorithm to attenuate tonal noise of a known frequency by feedback control. However, due to the uneven response of the speakers, feedback control is found to be only moderately effective even for this narrow-band application. Feedforward control proves to be most capable for the flat panel speaker. Using feedforward control, the sound pressure level can be significantly reduced in close proximity to an error microphone. The paper demonstrates an interesting application of the flat panel in which the panel is placed in the path of sound and effectively used to block sound transmission using feedforward control. This is a new approach to active noise control enabled by the use of flat panels and can be used to prevent sound from entering into an enclosure in the first place rather than the traditional approach of attempting to cancel sound after it enters the enclosure.

  6. Selection of population controls for a Salmonella case-control study in the UK using a market research panel and web-survey provides time and resource savings.

    PubMed

    Mook, P; Kanagarajah, S; Maguire, H; Adak, G K; Dabrera, G; Waldram, A; Freeman, R; Charlett, A; Oliver, I

    2016-04-01

    Timely recruitment of population controls in infectious disease outbreak investigations is challenging. We evaluated the timeliness and cost of using a market research panel as a sampling frame for recruiting controls in a case-control study during an outbreak of Salmonella Mikawasima in the UK in 2013. We deployed a web-survey by email to targeted members of a market research panel (panel controls) in parallel to the outbreak control team interviewing randomly selected public health staff by telephone and completing paper-based questionnaires (staff controls). Recruitment and completion of exposure history web-surveys for panel controls (n = 123) took 14 h compared to 15 days for staff controls (n = 82). The average staff-time cost per questionnaire for staff controls was £13·13 compared to an invoiced cost of £3·60 per panel control. Differences in the distribution of some exposures existed between these control groups but case-control studies using each group found that illness was associated with consumption of chicken outside of the home and chicken from local butchers. Recruiting market research panel controls offers time and resource savings. More rapid investigations would enable more prompt implementation of control measures. We recommend that this method of recruiting controls is considered in future investigations and assessed further to better understand strengths and limitations.

  7. VIEW OF PDP AND LTR CONTROL PANEL (LEFT) AND HEAVY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF PDP AND LTR CONTROL PANEL (LEFT) AND HEAVY WATER CONTROL PANEL (RIGHT) AT SOUTH END OF PDP CONTROL ROOM, LEVEL 0’, LOOKING SOUTH - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  8. 6. COMPRESSOR CONTROL PANELS: AT LEFT, 6,000 P.S.I. PANEL, CIRCA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. COMPRESSOR CONTROL PANELS: AT LEFT, 6,000 P.S.I. PANEL, CIRCA 1957; AT RIGHT, FACING CAMERA, 10,000 P.S.I. PANEL. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Helium Compression Plant, Test Area 1-115, intersection of Altair & Saturn Boulevards, Boron, Kern County, CA

  9. An Experimental Evaluation of Cross-Vane Panel Traps for the Collection of Sylvatic Triatomines (Hemiptera: Reduviidae).

    PubMed

    Updyke, Erin Allmann; Allan, Brian F

    2018-02-28

    Due to the limited understanding of the sylvatic cycle of Chagas disease transmission, an efficient method to attract and capture sylvatic triatomines (Hemiptera: Reduviidae) is essential to monitor human exposure risk. Current collection methods for sylvatic species, though effective, are labor- and time-intensive. This study evaluated whether modified cross-vane panel traps (commonly used in forest entomology) can be used to attract and capture flying life-stages of sylvatic triatomines and whether a commercially available lure is effective in attracting sylvatic triatomines in the field. We evaluated four trap treatments in both the wet and dry seasons in central Panama: a cross-vane panel trap fitted with an ultraviolet (UV) light, a cross-vane panel trap fitted with a commercially available human-volatile lure, a cross-vane panel trap fitted with both a UV light and a human-volatile lure, and a white sheet fitted with a UV light (a standard collection method) as a control. A total of 45 adult Rhodnius pallescens Barber were captured across 10 nights of trapping representing 112 trap-nights. There was a significant overall effect of trap type on collection success; sheet traps collected more triatomines than lure traps, and there were no differences between the sheet trap and the UV trap, nor between the sheet trap and the UV + lure trap. The lure-only trap did not capture any triatomines in this study. These results indicate that cross-vane panel traps with a UV light are as effective as a sheet trap but offer the advantage of requiring less time and effort to maintain and monitor.

  10. 15. INTERIOR OVERVIEW TO SOUTHEAST. ACTIVE CONTROL PANEL AND GENERATORS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. INTERIOR OVERVIEW TO SOUTHEAST. ACTIVE CONTROL PANEL AND GENERATORS AT LEFT, HISTORIC CONTROL PANEL AT RIGHT. - Santa Ana River Hydroelectric System, SAR-1 Powerhouse, Redlands, San Bernardino County, CA

  11. Delivery system characteristics and their association with quality and costs of care: implications for accountable care organizations.

    PubMed

    Chukmaitov, Askar; Harless, David W; Bazzoli, Gloria J; Carretta, Henry J; Siangphoe, Umaporn

    2015-01-01

    Implementation of accountable care organizations (ACOs) is currently underway, but there is limited empirical evidence on the merits of the ACO model. The aim was to study the associations between delivery system characteristics and ACO competencies, including centralization strategies to manage organizations, hospital integration with physicians and outpatient facilities, health information technology, infrastructure to monitor community health and report quality, and risk-adjusted 30-day all-cause mortality and case-mixed-adjusted inpatient costs for the Medicare population. Panel data (2006-2009) were assembled from Florida and multiple sources: inpatient hospital discharge, vital statistics, the American Hospital Association, the Healthcare Information and Management Systems Society, and other databases. We applied a panel study design, controlling for hospital and market characteristics. Hospitals that were in centralized health systems or became more centralized over the study period had significantly larger reductions in mortality compared with hospitals that remained freestanding. Surprisingly, tightly integrated hospital-physician arrangements were associated with increased mortality; as such, hospitals may wish to proceed cautiously when developing specific types of alignment with local physician organizations. We observed no statistically significant differences in the growth rate of costs across hospitals in any of the health systems studied relative to freestanding hospitals. Although we observed quality improvement in some organizational types, these outcome improvements were not coupled with the additional desired objective of lower cost growth. This implies that additional changes not present during our study period, potentially changes in provider payment approaches, are essential for achieving the ACO objectives of higher quality of care at lower costs. Provider organizations implementing ACOs should consider centralizing service delivery as a viable strategy to improve quality of care, although the strategy did not result in lower cost growth.

  12. Active control of sound radiation from a vibrating rectangular panel by sound sources and vibration inputs - An experimental comparison

    NASA Technical Reports Server (NTRS)

    Fuller, C. R.; Hansen, C. H.; Snyder, S. D.

    1991-01-01

    Active control of sound radiation from a rectangular panel by two different methods has been experimentally studied and compared. In the first method a single control force applied directly to the structure is used with a single error microphone located in the radiated acoustic field. Global attenuation of radiated sound was observed to occur by two main mechanisms. For 'on-resonance' excitation, the control force had the effect of increasing the total panel input impedance presented to the nosie source, thus reducing all radiated sound. For 'off-resonance' excitation, the control force tends not significantly to modify the panel total response amplitude but rather to restructure the relative phases of the modes leading to a more complex vibration pattern and a decrease in radiation efficiency. For acoustic control, the second method, the number of acoustic sources required for global reduction was seen to increase with panel modal order. The mechanism in this case was that the acoustic sources tended to create an inverse pressure distribution at the panel surface and thus 'unload' the panel by reducing the panel radiation impedance. In general, control by structural inputs appears more effective than control by acoustic sources for structurally radiated noise.

  13. Active control of aircraft engine inlet noise using compact sound sources and distributed error sensors

    NASA Technical Reports Server (NTRS)

    Burdisso, Ricardo (Inventor); Fuller, Chris R. (Inventor); O'Brien, Walter F. (Inventor); Thomas, Russell H. (Inventor); Dungan, Mary E. (Inventor)

    1996-01-01

    An active noise control system using a compact sound source is effective to reduce aircraft engine duct noise. The fan noise from a turbofan engine is controlled using an adaptive filtered-x LMS algorithm. Single multi channel control systems are used to control the fan blade passage frequency (BPF) tone and the BPF tone and the first harmonic of the BPF tone for a plane wave excitation. A multi channel control system is used to control any spinning mode. The multi channel control system to control both fan tones and a high pressure compressor BPF tone simultaneously. In order to make active control of turbofan inlet noise a viable technology, a compact sound source is employed to generate the control field. This control field sound source consists of an array of identical thin, cylindrically curved panels with an inner radius of curvature corresponding to that of the engine inlet. These panels are flush mounted inside the inlet duct and sealed on all edges to prevent leakage around the panel and to minimize the aerodynamic losses created by the addition of the panels. Each panel is driven by one or more piezoelectric force transducers mounted on the surface of the panel. The response of the panel to excitation is maximized when it is driven at its resonance; therefore, the panel is designed such that its fundamental frequency is near the tone to be canceled, typically 2000-4000 Hz.

  14. Active control of aircraft engine inlet noise using compact sound sources and distributed error sensors

    NASA Technical Reports Server (NTRS)

    Burdisso, Ricardo (Inventor); Fuller, Chris R. (Inventor); O'Brien, Walter F. (Inventor); Thomas, Russell H. (Inventor); Dungan, Mary E. (Inventor)

    1994-01-01

    An active noise control system using a compact sound source is effective to reduce aircraft engine duct noise. The fan noise from a turbofan engine is controlled using an adaptive filtered-x LMS algorithm. Single multi channel control systems are used to control the fan blade passage frequency (BPF) tone and the BPF tone and the first harmonic of the BPF tone for a plane wave excitation. A multi channel control system is used to control any spinning mode. The multi channel control system to control both fan tones and a high pressure compressor BPF tone simultaneously. In order to make active control of turbofan inlet noise a viable technology, a compact sound source is employed to generate the control field. This control field sound source consists of an array of identical thin, cylindrically curved panels with an inner radius of curvature corresponding to that of the engine inlet. These panels are flush mounted inside the inlet duct and sealed on all edges to prevent leakage around the panel and to minimize the aerodynamic losses created by the addition of the panels. Each panel is driven by one or more piezoelectric force transducers mounted on the surface of the panel. The response of the panel to excitation is maximized when it is driven at its resonance; therefore, the panel is designed such that its fundamental frequency is near the tone to be canceled, typically 2000-4000 Hz.

  15. 3. Credit BG. The interior of the control room appears ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Credit BG. The interior of the control room appears in this view, looking north (0°). The control console in the room center permitted remote control of various propellant grinders and mixers in surrounding buildings. Television monitors (absent from their mounts in this view) permitted direct viewing of operating machinery. From foreground to background: Panel (1) contains OGAR warning light switches for Curing Buildings E-39, E-40, E-41 and E-86; (O=off, G=green safe, A=amber caution, R=red danger) Panel (2) E-85 Oxidizer Dryer Building console: OGAR switch Panel (3) E-84 Oxidizer Grinder Building console: controls for vibrator, feed, and hammer; Panel (4) E-36 Oxidizer Grinder Building console: controls for vibrator, feed, hammer, attritor, and SWECO ("SWECO" undefined) Panels (5) & (6) blank Panel (7) E-38 Mixer & Casting Building console: vacuum pump, blender, heating and cooling controls Panel (8) E-37 Mixer & Casting Building console: motor controls for 1 pint, 1 gallon, 5 gallon and 30 gallon mixers; vacuum pump, deluge (fire suppression), pot up/down, vibrator, feed, and SWECO. - Jet Propulsion Laboratory Edwards Facility, Weigh & Control Building, Edwards Air Force Base, Boron, Kern County, CA

  16. Use of Vital Pulp Therapies in Primary Teeth with Deep Caries Lesions.

    PubMed

    Dhar, Vineet; Marghalani, Abdullah A; Crystal, Yasmi O; Kumar, Ashok; Ritwik, Priyanshi; Tulunoglu, Ozlem; Graham, Laurel

    2017-09-15

    This manuscript presents evidence-based guidance on the use of vital pulp therapies for treatment of deep caries lesions in children. A guideline panel convened by the American Academy of Pediatric Dentistry formulated evidence-based recommendations on three vital pulp therapies: indirect pulp treatment (IPT; also known as indirect pulp cap), direct pulp cap (DPC), and pulpotomy. The basis of the guideline's recommendations was evidence from "Primary Tooth Vital Pulp Therapy: A Systematic Review and Meta-Analysis." (Pediatr Dent 2017;15;39[1]:16-23.) A systematic search was conducted in PubMed®/MEDLINE, Embase®, Cochrane Central Register of Controlled Trials, and trial databases to identify randomized controlled trials and systematic reviews addressing peripheral issues of vital pulp therapies such as patient preferences of treatment and impact of cost. Quality of the evidence was assessed through the Grading of Recommendations Assessment, Development, and Evaluation approach; the evidence-to-decision framework was used to formulate a recommendation. The panel was unable to make a recommendation on superiority of any particular type of vital pulp therapy owing to lack of studies directly comparing these interventions. The panel recommends use of mineral trioxide aggregate (MTA) and formocresol in pulpotomy treatments; these are recommendations based on moderate-quality evidence at 24 months. The panel made weak recommendations regarding choice of medicament in both IPT (moderate-quality evidence [24 months], low quality evidence [48 months]) and DPC (very-low quality evidence [24 months]). Success of both treatments was independent of type of medicament used. The panel also recommends use of ferric sulfate (low-quality evidence), lasers (low-quality evidence), sodium hypochlorite (very low-quality evidence), and tricalcium silicate (very low-quality evidence) in pulpotomies; these are weak recommendations based on low-quality evidence. The panel recommended against the use of calcium hydroxide as pulpotomy medicament in primary teeth with deep caries lesions. Conclusions and practical implications: The guideline intends to inform the clinical practices with evidence-based recommendations on vital pulp therapies in primary teeth with deep caries lesions. These recommendations are based upon the best available evidence to-date.

  17. Evaporating Atmospheres Around Close-in Exoplanets.

    NASA Astrophysics Data System (ADS)

    Owen, J.; Jackson, A.; Wu, Y.; Adams, F.

    2014-12-01

    The majority of currently observed exoplanets appear exceeding close to the central star (<0.1 AU) and as such are subject to intense high energy radiation from UV & X-ray photons. We will discuss that in such environments the atmospheres these planets are heated sufficiently that they can escape the planet's gravitational field in a hydrodynamic trans-sonic wind. We will show that this hydrodynamic mass-loss occurs for the majority of exoplanets at short periods, and for low-mass planets (<50 Mearth) is vigorous enough to significantly alter the planet's evolution. In some cases we will argue that an originally gas rich exoplanet can be completely evaporated leaving behind a bare rock core. In addition, we will present new multi-dimensional simulations of evaporation that include realistic treatment of the radiative transfer. These new simulations show that evaporation from 'hot' Jupiters is likely to be magnetically controlled, where mass-loss can only occur along open filed lines, where the interaction between the stellar and planetary magnetic field strongly controls the geometry of the evaporative flow. We will indicate how these new multi-dimensional radiation-magneto-hydrodynamic calculations can be used to study the time-dependence of the outflow and link the small but growing number of observations of exoplanet evaporation to the theoretical models. Finally, we will indicate that asymmetric evaporative flows can lead to orbital evolution of planets at close separations. Figure Caption: "Flow structure from an evaporating Hot Jupiter with a magnetic field strength of 0.3 Gauss. Top panels show density and magnetic field configuration and bottom panel shows plasma beta and velocity structure; left panels show simulation domain, right panels show a zoom in on the planet."

  18. THE RESEARCH TRIANGLE PARK PARTICULATE MATTER PANEL STUDY: MODELING AMBIENT SOURCE CONTRIBUTION TO PERSONAL AND RESIDENTIAL PM MASS CONCENTRATIONS

    EPA Science Inventory

    The Research Triangle Park (RTP) Particulate Matter (PM) Panel Study represented a one-year investigation of personal, residential and ambient PM mass concentrations across distances as large as 70 km in central North Carolina. One of the primary goals of this effort was to est...

  19. Integrated Power Source Grant

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Traditional spacecraft power systems incorporate a solar array energy source, an energy storage element (battery), and battery charge control and bus voltage regulation electronics to provide continuous electrical power for spacecraft systems and instruments. Dedicated power conditioning components provide limited fault isolation between systems and instruments, while a centralized power-switching unit provides spacecraft load control. Battery undervoltage conditions are detected by the spacecraft processor, which removes fault conditions and non-critical loads before permanent battery damage can occur. Cost effective operation of a micro-sat constellation requires a fault tolerant spacecraft architecture that minimizes on-orbit operational costs by permitting autonomous reconfiguration in response to unexpected fault conditions. A new micro-sat power system architecture that enhances spacecraft fault tolerance and improves power system survivability by continuously managing the battery charge and discharge processes on a cell-by-cell basis has been developed. This architecture is based on the Integrated Power Source (US patent 5644207), which integrates dual junction solar cells, Lithium Ion battery cells, and processor based charge control electronics into a structural panel that can be deployed or used to form a portion of the outer shell of a micro-spacecraft. The first generation Integrated Power Source is configured as a one inch thick panel in which prismatic Lithium Ion battery cells are arranged in a 3x7 matrix (26VDC) and a 3x1 matrix (3.7VDC) to provide the required output voltages and load currents. A multi-layer structure holds the battery cells, as well as the thermal insulators that are necessary to protect the Lithium Ion battery cells from the extreme temperatures of the solar cell layer. Independent thermal radiators, located on the back of the panel, are dedicated to the solar cell array, the electronics, and the battery cell array. In deployed panel applications, these radiators maintain the battery cells in an appropriate operational temperature range.

  20. 52. VIEW OF REMAINS OF ORIGINAL 1907 CONTROL PANEL, LOCATED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    52. VIEW OF REMAINS OF ORIGINAL 1907 CONTROL PANEL, LOCATED ON NORTH WALL OF EAST END OF CONTROL ROOM. PORTIONS OF THIS PANEL REMAINED IN USE UNTIL THE PLANT CLOSED. THE METERS AND CONTROLS ARE MOUNTED ON SOAPSTONE PANELS. THE INSTRUMENT IN THE LEFT CENTER OF THE PHOTOGRAPH IS A TIRRILL VOLTAGE REGULATOR. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  1. Designing low cost LED display for the billboard

    NASA Astrophysics Data System (ADS)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  2. 69. DETAIL OF OPERATIONS AND CHECKOUT (POWER CONTROL AND MONITOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. DETAIL OF OPERATIONS AND CHECKOUT (POWER CONTROL AND MONITOR PANEL) AND RANGE SAFETY (DESTRUCT SYSTEM CONTROL MONITOR PANEL) PANELS IN SLC-3E CONTROL ROOM - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. Limit Theory for Panel Data Models with Cross Sectional Dependence and Sequential Exogeneity

    PubMed Central

    Kuersteiner, Guido M.; Prucha, Ingmar R.

    2013-01-01

    The paper derives a general Central Limit Theorem (CLT) and asymptotic distributions for sample moments related to panel data models with large n. The results allow for the data to be cross sectionally dependent, while at the same time allowing the regressors to be only sequentially rather than strictly exogenous. The setup is sufficiently general to accommodate situations where cross sectional dependence stems from spatial interactions and/or from the presence of common factors. The latter leads to the need for random norming. The limit theorem for sample moments is derived by showing that the moment conditions can be recast such that a martingale difference array central limit theorem can be applied. We prove such a central limit theorem by first extending results for stable convergence in Hall and Hedye (1980) to non-nested martingale arrays relevant for our applications. We illustrate our result by establishing a generalized estimation theory for GMM estimators of a fixed effect panel model without imposing i.i.d. or strict exogeneity conditions. We also discuss a class of Maximum Likelihood (ML) estimators that can be analyzed using our CLT. PMID:23794781

  4. The new 34-meter antenna

    NASA Technical Reports Server (NTRS)

    Pompa, M. F.

    1986-01-01

    The new 34-m high efficiency Azimuth - Elevation antenna configuration, including its features, dynamic characteristics and performance at 8.4-GHz frequencies is described. The current-technology features of this antenna produce a highly reliable configuration by incorporation of a main wheel and track azimuth support, central pintle pivot bearing, close tolerance surface panels and all-welded construction. Also described are basic drive controls that, as slaved to three automatic microprocessors, provide accurate and safe control of the antenna's steering tasks. At this time antenna installations are completed at Goldstone and Canberra and have operationally supported the Voyager - Uranus encounter. A third installation is being constructed currently in Madrid and is scheduled for completion in late 1986.

  5. SPERTI Control Building (PER601) interior. Control panel with data readout ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SPERT-I Control Building (PER-601) interior. Control panel with data readout equipment in control room. Panels and equipment were fabricated elsewhere at NRTS during SPERT-I construction. Photographer: R.G. Larsen. Date: November 21, 1955. INEEL negative no. 55-3208 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  6. Slewing control experiment for a flexible panel

    NASA Technical Reports Server (NTRS)

    Juang, Jer-Nan

    1987-01-01

    Technology areas are identified in which better analytical and/or experimental methods are needed to adequately and accurately control the dynamic responses of multibody space platforms such as the space station. A generic space station solar panel is used to experimentally evaluate current control technologies. Active suppression of solar panel vibrations induced by large angle maneuvers is studied with a torque actuator at the root of the solar panel. These active suppression tests will identify the hardware requirements and adequacy of various controller designs.

  7. A Comparative Study of the Perceptions of Professional Staff on Their Contribution to Student Outcomes

    ERIC Educational Resources Information Center

    Regan, Julie-Anne; Dollard, Emma; Banks, Nicci

    2014-01-01

    This study examined the perceptions of professional staff on their contribution to student outcomes. An online Delphi survey method was used to collect data from two expert panels: professional staff based in faculties and professional staff based in central university departments. The aim of this method is for the panels to reach consensus. The…

  8. Quality control of involved field radiotherapy in the HD 13 and HD 14 trials : Report of the radiotherapy panel of the German Hodgkin Study Group (GHSG).

    PubMed

    Kriz, J; Baues, C; Engenhart-Cabillic, R; Haverkamp, U; Herfart, K; Lukas, P; Plütschow, A; Schmidberger, H; Staar, S; Fuchs, M; Engert, A; Eich, H T

    2017-02-01

    As part of the foundation of the German Hodgkin Study Group (GHSG) in 1978, a central radiotherapy (RT) reference centre was established to evaluate and to improve the quality of treatment. During the study generations, the quality assurance programs (QAP) were continued and adapted to the demands of each study. The purpose of this article is to demonstrate the results of the fifth study generation and to compare them to the previous findings. With the start of the fourth GHSG study generation (HD10-12), a central prospective review of all diagnostic images was established to create an individual treatment plan for each early stage study patient. The quality of involved field RT was retrospectively evaluated by an expert panel of radiation oncologists. In the fifth study generation (HD13-15), the retrospective review of radiotherapy performed was refined and the results were compared with the findings of the fourth generation. The expert panel analyzed the RT planning and application of 1037 (28 %) patients (HD13 n = 465, HD14 n = 572). Simulation films were available in 85 % of cases and verification films in 87 %. RT was assessed as major violation in 46 % (HD13 = 38 %, HD14 = 52 %), minor violation in 9 % (HD13 = 9 %, HD14 = 9 %) and according to the protocol in 45 % (HD13 = 52 %, HD14 = 38 %). The value for QAP of RT within the GHSG trials is well known. Still there were several protocol violations. In the future, the QAP program has to be adapted to the requirements of "modern RT" in malignant lymphoma.

  9. Cancer Control in Central and Eastern Europe: Current Situation and Recommendations for Improvement.

    PubMed

    Vrdoljak, Eduard; Bodoky, Gyorgy; Jassem, Jacek; Popescu, Razvan A; Mardiak, Jozef; Pirker, Robert; Čufer, Tanja; Bešlija, Semir; Eniu, Alexandru; Todorović, Vladimir; Kubáčková, Kateřina; Kurteva, Galia; Tomašević, Zorica; Sallaku, Agim; Smichkoska, Snezhana; Bajić, Žarko; Šikić, Branimir I

    2016-10-01

    : The incidence of many cancers is higher in Western European (WE) countries, but mortality is frequently higher in Central and Eastern European (CEE) countries. A panel of oncology leaders from CEE countries participating in the South Eastern European Research Oncology Group (SEEROG) was formed in 2015, aiming to analyze the current status and trends of oncology care in CEE and to propose recommendations leading to improved care and outcomes. The SEEROG panel, meeting during the 11th Central European Oncology Congress, proposed the following: (a) national cancer control plans (NCCPs) required in all CEE countries, defining priorities in cancer care, including finance allocation considering limited health care budgets; (b) national cancer registries, describing in detail epidemiological trends; (c) efforts to strengthen comprehensive cancer centers; (d) that multidisciplinary care should be mandated by the NCCPs; (e) that smaller hospitals should be connected to multidisciplinary tumor boards via the Internet, providing access to specialized expertise; (f) nationwide primary prevention programs targeting smoking, obesity, and alcohol consumption and centrally evaluated secondary prevention programs for cervical, colorectal, and breast cancers; (g) prioritize education for all involved in cancer care, including oncology nurses, general practitioners, and palliative care providers; (h) establish outpatient care in day hospitals to reduce costs associated with the current inpatient model of care in CEE countries and to improve patients' quality of life; (i) long-term pharmacoeconomic evaluations of new therapies in CEE countries; (j) increase national oncology budgets in view of the higher mortality rates in CEE compared with WE countries; and (k) CEE countries urgently need help from the European Union to increase and monitor overall investment in cancer care. Significant differences in cancer incidence and mortality have been observed between European countries. While the incidence of many cancer types is higher in Western European (WE) countries, the mortality is generally higher in Central and Eastern Europe (CEE). The primary purpose of this review was to describe the current status and trends of oncology care in the CEE region, to raise awareness among physicians, regulators, and payers, and to propose the most needed changes in order to make the oncology care in CEE closer to the WE standards. ©AlphaMed Press.

  10. 77 FR 2549 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Grants for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Grants for Injury Control Research Centers (Panel 3), Funding Opportunity Announcement (FOA) CE12-001, Initial Review In accordance with Section 10(a)(2) of the Federal Advisory...

  11. 75 FR 30844 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Conducting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Conducting Public Health Research... in response to ``Conducting Public Health Research in Kenya (Panel B),'' FOA GH10-003. Contact Person...

  12. 75 FR 28810 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Conducting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-24

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Conducting Public Health Research... in response to ``Conducting Public Health Research in Kenya (Panel C),'' FOA GH10-003. Contact Person...

  13. 76 FR 4703 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy Risk Assessment Monitoring System (PRAMS), DP11-001 Panel D, Initial Review Notice of Cancellation: This notice was published...

  14. 76 FR 5379 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-31

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy Risk Assessment..., discussion, and evaluation of ``Pregnancy Risk Assessment Monitoring System (PRAMS), DP11-001 Panels A, B...

  15. The Structure and Stability of Political Attitudes: Findings from the 1974-1976 Dearborn Panel Study.

    ERIC Educational Resources Information Center

    Wayman, Frank Whelon; Stockton, Ronald R.

    Based on a panel study of 800 voters in Dearborn, Michigan, this report examines the impact of political attitudes on the party system and on the presidential elections of 1972 and 1976. The central thesis is that public opinion can be classified into two clusters of attitudes, one which disrupts and the other which reinforces partisan voting. The…

  16. 141. Detail of east control panel in control room, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    141. Detail of east control panel in control room, looking east. This panel contains electrical switches that were used to control valves at circular forebay. It also contains voltage regulators, synchroscope adjust field breaker, ammeters, wattmeters, temperature indicator of generator windings, and butterfly valve and governor controls. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  17. 140. Detail of north control panel in control room, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    140. Detail of north control panel in control room, looking north. This panel monitors a variety of activities: gages indicate the level of Lake Tapps and level of the circular forebay; wattmeters indicate output of exciters. Photo by Jet Lowe, HAER, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  18. Panel Management to Improve Smoking and Hypertension Outcomes by VA Primary Care Teams: A Cluster-Randomized Controlled Trial.

    PubMed

    Schwartz, Mark D; Jensen, Ashley; Wang, Binhuan; Bennett, Katelyn; Dembitzer, Anne; Strauss, Shiela; Schoenthaler, Antoinette; Gillespie, Colleen; Sherman, Scott

    2015-07-01

    Panel Management can expand prevention and chronic illness management beyond the office visit, but there is limited evidence for its effectiveness or guidance on how best to incorporate it into practice. We aimed to test the effectiveness of incorporating panel management into clinical practice by incorporating Panel Management Assistants (PMAs) into primary care teams with and without panel management education. We conducted an 8-month cluster-randomized controlled trial of panel management for improving hypertension and smoking cessation outcomes among veterans. Twenty primary care teams from the Veterans Affairs New York Harbor were randomized to control, panel management support, or panel management support plus education groups. Teams included 69 clinical staff serving 8,153 hypertensive and/or smoking veterans. Teams assigned to the intervention groups worked with non-clinical Panel Management Assistants (PMAs) who monitored care gaps and conducted proactive patient outreach, including referrals, mail reminders and motivational interviewing by telephone. Measurements included mean systolic and diastolic blood pressure, proportion of patients with controlled blood pressure, self-reported quit attempts, nicotine replacement therapy (NRT) prescriptions, and referrals to disease management services. Change in mean blood pressure, blood pressure control, and smoking quit rates were similar across study groups. Patients on intervention teams were more likely to receive NRT (OR = 1.4; 95% CI 1.2-1.6) and enroll in the disease management services MOVE! (OR = 1.2; 95% CI 1.1-1.6) and Telehealth (OR = 1.7, 95% CI 1.4-2.1) than patients on control teams. Panel Management support for primary care teams improved process, but not outcome variables among veterans with hypertension and smoking. Incorporating PMAs into teams was feasible and highly valued by the clinical staff, but clinical impact may require a longer intervention.

  19. 14. View toward the northwest corner of the basement in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. View toward the northwest corner of the basement in the north segment of the building. Portions of the basement floor are earth, and portions are concrete. For some undetermined reason an unbonded, narrow panel of brick occurs in the west (left) wall. A corbeled brick footing is seen under this panel, as if the panel is carrying a concentrated load. An identical element occurs to the left, outside the camera's view. These 'columns' may support the second-story brick facade over the ground floor store windows. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  20. Buckling Behavior of Compression-Loaded Quasi-Isotropic Curved Panels with a Circular Cutout

    NASA Technical Reports Server (NTRS)

    Hilburger, Mark W.; Britt, Vicki O.; Nemeth, Michael P.

    1999-01-01

    Results from a numerical and experimental study of the response of compression-loaded quasi-isotropic curved panels with a centrally located circular cutout are presented. The numerical results were obtained by using a geometrically nonlinear finite element analysis code. The effects of cutout size, panel curvature and initial geo- metric imperfections on the overall response of compression-loaded panels are described. In addition, results are presented from a numerical parametric study that indicate the effects of elastic circumferential edge restraints on the prebuckling and buckling response of a selected panel and these numerical results are compared to experimentally measured results. These restraints are used to identify the effects of circumferential edge restraints that are introduced by the test fixture that was used in the present study. It is shown that circumferential edge restraints can introduce substantial nonlinear prebuckling deformations into shallow compression-loaded curved panels that can results in a significant increase in buckling load.

  1. Behavior of Frame-Stiffened Composite Panels with Damage

    NASA Technical Reports Server (NTRS)

    Jegley, Dawn C.

    2013-01-01

    NASA, the Air Force Research Laboratory and The Boeing Company have worked to develop new low-cost, light-weight composite structures for aircraft. A Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept has been developed which offers advantages over traditional metallic structures. In this concept, a stitched carbon-epoxy material system has been developed with the potential for reducing the weight and cost of transport aircraft structure by eliminating fasteners, thereby reducing part count and labor. Stitching and the use of thin skins with rod-stiffeners to move loading away from the morevulnerable outer surface produces a structurally efficient, damage tolerant design. This study focuses on the behavior of PRSEUS panels loaded in the frame direction and subjected to severe damage in the form of a severed central frame in a three-frame panel. Experimental results for a pristine two-frame panel and analytical predictions for pristine two-frame and three-frame panels as well as damaged three-frame panels are described.

  2. VIEW OF PDP CONTROL ROOM PANELS, LEVEL 0’, LOOKING WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF PDP CONTROL ROOM PANELS, LEVEL 0’, LOOKING WEST. THESE PANELS WERE WHERE THE A-MOTOR TAPES WOULD HAVE BEEN VISIBLE IN THE CONTROL ROOM. MORE RECENT MONITOR IN UPPER CENTER FOR “LTR FLUX MONITORS” - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  3. Processor architectures utilizing magnetic bubble and semi-conductor memories. [for the Omega navigation system

    NASA Technical Reports Server (NTRS)

    Parrish, E. A., Jr.; Aylor, J. H.

    1975-01-01

    To aid work being conducted on the feasibility of a low cost Omega navigational receiver, a control panel was designed and constructed according to supplied specifications. Since the proposed Omega receiver is designed around a microprocessor, software engineering necessary for control panel operation is included in the design. The control panel is to be used as an operational model for use in the design of a prototype receiver. A detailed description of the hardware design is presented along with a description of the software needed to operate the panel. A complete description of the operating procedures for the panel are also included.

  4. Experimental and theoretical sound transmission. [reduction of interior noise in aircraft

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Muirhead, V. U.; Smith, H. W.; Durenberger, D. W.

    1978-01-01

    The capabilities of the Kansas University- Flight Research Center for investigating panel sound transmission as a step toward the reduction of interior noise in general aviation aircraft were discussed. Data obtained on panels with holes, on honeycomb panels, and on various panel treatments at normal incidence were documented. The design of equipment for panel transmission loss tests at nonnormal (slanted) sound incidence was described. A comprehensive theory-based prediction method was developed and shows good agreement with experimental observations of the stiffness controlled, the region, the resonance controlled region, and the mass-law region of panel vibration.

  5. Heat pipe thermal conditioning panel

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.; Loose, J. D.; Mccoy, K. E.

    1974-01-01

    Thermal control of electronic hardware and experiments on future space vehicles is critical to proper functioning and long life. Thermal conditioning panels (cold plates) are a baseline control technique in current conceptual studies. Heat generating components mounted on the panels are typically cooled by fluid flowing through integral channels within the panel. However, replacing the pumped fluid coolant loop within the panel with heat pipes offers attractive advantages in weight, reliability, and installation. This report describes the development and fabrication of two large 0.76 x 0.76 m heat pipe thermal conditioning panels to verify performance and establish the design concept.

  6. Assessment of the U. S. outer continental shelf environmental studies program. 1. Physical oceanography. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Federal responsibility for oil and gas development on the U.S. outer continental shelf (OCS) resides with the Minerals Management Service (MMS) of the U.S. Department of the Interior (DOI). The DOI's Environmental Studies Program (ESP) is the program through which MMS conducts environmental studies on the OCS and collects information to prepare environmental impact statements (EISs). It appeared to MMS in 1986 that the time was ripe to assess the status of the present program and to explore the needs for future studies. MMS requested an evaluation of the adequacy and applicability of ESP studies, a review of the generalmore » state of knowledge in the appropriate disciplines, and recommendations for future studies. Three panels were established, one of which, the Physical Oceanography Panel, investigated the physical oceanographic aspects of the ESP, the subject of the report, which is the first of three in a series. In reviewing the ESP's physical oceanography program, the panel evaluated the quality and relevance of studies carried out in waters under federal control, which extend from the limits of state jurisdictions (3-12 miles offshore) and include the central and outer continental shelf waters and the continental slope.« less

  7. Development of the technology for the fabrication of reliable laminar from control panels

    NASA Technical Reports Server (NTRS)

    Meade, L. E.; Kays, A. O.; Ferrill, R. S.; Young, H. R.

    1977-01-01

    Materials were assessed and fabrication techniques were developed for use in the manufacture of wing surface materials compatible with the application of both aluminum alloys and nonmetallic composites. The concepts investigated included perforations and slots in the metallic test panels and microporosity and perforations in the composite test panels. Perforations were produced in the metallic test panels by the electron beam process and slots were developed by controlled gaps between the metal sheets. Microporosity was produced in the composite test panels by the resin bleed process, and perforations were produced by the fugitive fiber technique. Each of these concepts was fabricated into test panels, and air flow tests were conducted on the panels.

  8. The Omics Dashboard for interactive exploration of gene-expression data.

    PubMed

    Paley, Suzanne; Parker, Karen; Spaulding, Aaron; Tomb, Jean-Francois; O'Maille, Paul; Karp, Peter D

    2017-12-01

    The Omics Dashboard is a software tool for interactive exploration and analysis of gene-expression datasets. The Omics Dashboard is organized as a hierarchy of cellular systems. At the highest level of the hierarchy the Dashboard contains graphical panels depicting systems such as biosynthesis, energy metabolism, regulation and central dogma. Each of those panels contains a series of X-Y plots depicting expression levels of subsystems of that panel, e.g. subsystems within the central dogma panel include transcription, translation and protein maturation and folding. The Dashboard presents a visual read-out of the expression status of cellular systems to facilitate a rapid top-down user survey of how all cellular systems are responding to a given stimulus, and to enable the user to quickly view the responses of genes within specific systems of interest. Although the Dashboard is complementary to traditional statistical methods for analysis of gene-expression data, we show how it can detect changes in gene expression that statistical techniques may overlook. We present the capabilities of the Dashboard using two case studies: the analysis of lipid production for the marine alga Thalassiosira pseudonana, and an investigation of a shift from anaerobic to aerobic growth for the bacterium Escherichia coli. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  9. The Omics Dashboard for interactive exploration of gene-expression data

    PubMed Central

    Paley, Suzanne; Parker, Karen; Spaulding, Aaron; Tomb, Jean-Francois; O’Maille, Paul

    2017-01-01

    Abstract The Omics Dashboard is a software tool for interactive exploration and analysis of gene-expression datasets. The Omics Dashboard is organized as a hierarchy of cellular systems. At the highest level of the hierarchy the Dashboard contains graphical panels depicting systems such as biosynthesis, energy metabolism, regulation and central dogma. Each of those panels contains a series of X–Y plots depicting expression levels of subsystems of that panel, e.g. subsystems within the central dogma panel include transcription, translation and protein maturation and folding. The Dashboard presents a visual read-out of the expression status of cellular systems to facilitate a rapid top-down user survey of how all cellular systems are responding to a given stimulus, and to enable the user to quickly view the responses of genes within specific systems of interest. Although the Dashboard is complementary to traditional statistical methods for analysis of gene-expression data, we show how it can detect changes in gene expression that statistical techniques may overlook. We present the capabilities of the Dashboard using two case studies: the analysis of lipid production for the marine alga Thalassiosira pseudonana, and an investigation of a shift from anaerobic to aerobic growth for the bacterium Escherichia coli. PMID:29040755

  10. Modular, Microprocessor-Controlled Flash Lighting System

    NASA Technical Reports Server (NTRS)

    Kiefer, Dwayne; Gray, Elizabeth; Skupinski, Robert; Stachowicz, Arthur; Birchenough, William

    2006-01-01

    A microprocessor-controlled lighting system generates brief, precisely timed, high-intensity flashes of light for scientific imaging at frame rates up to about 1 kHz. The system includes an array of light-emitting diodes (LEDs) that are driven in synchronism with an externally generated timing signal (for example, a timing signal generated by a video camera). The light output can be varied in peak intensity, pulse duration, pulse delay, and pulse rate, all depending on the timing signal and associated externally generated control signals. The array of LEDs comprises as many as 16 LED panels that can be attached together. Each LED panel is a module consisting of a rectangular subarray of 10 by 20 LEDs of advanced design on a printed-circuit board in a mounting frame with a power/control connector. The LED panels are controlled by an LED control module that contains an AC-to-DC power supply, a control board, and 8 LED-panel driver boards. In prior LED panels, the LEDs are packaged at less than maximum areal densities in bulky metal housings that reduce effective active areas. In contrast, in the present LED panels, the LEDs are packed at maximum areal density so as to afford 100-percent active area and so that when panels are joined side by side to form the array, there are no visible seams between them and the proportion of active area is still 100 percent. Each panel produces an illuminance of .5 x 10( exp 4) lux at a distance of 5.8 in. (approx.1.6 cm). The LEDs are driven according to a pulse-width-modulation control scheme that makes it safe to drive the LEDs beyond their rated steady-state currents in order to generate additional light during short periods. The drive current and the pulse-width modulation for each LED panel can be controlled independently of those of the other 15 panels. The maximum allowable duration of each pulse of drive current is a function of the amount of overdrive, the total time to be spent in overdrive operation, and the limitations of the LEDs. The system is configured to limit the overdrive according to values specific to each type of LED in the array. These values are coded into firmware to prevent inadvertent damage to the LED panels.

  11. Study of the damping characteristics of general aviation aircraft panels and development of computer programs to calculate the effectiveness of interior noise control treatment, part 1

    NASA Technical Reports Server (NTRS)

    Navaneethan, R.; Hunt, J.; Quayle, B.

    1982-01-01

    Tests were carried out on 20 inch x 20 inch panels at different test conditions using free-free panels, clamped panels, and panels as installed in the KU-FRL acoustic test facility. Tests with free-free panels verified the basic equipment set-up and test procedure. They also provided a basis for comparison. The results indicate that the effect of installed panels is to increase the damping ratio at the same frequency. However, a direct comparison is not possible, as the fundamental frequency of a free-free panel differs from the resonance frequency of the panel when installed. The damping values of panels installed in the test facility are closer to the damping values obtained with fixed-fixed panels. Effects of damping tape, stiffeners, and bonded and riveted edged conditions were also investigated. Progress in the development of a simple interior noise level control program is reported.

  12. DETAIL INTERIOR VIEW OF CONTROL PANEL IN CONTROL STATION, VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL INTERIOR VIEW OF CONTROL PANEL IN CONTROL STATION, VIEW TOWARDS WEST - St. Lucie Canal, Lock No. 1, Control Station, St. Lucie, Cross State Canal, Okeechobee Intracoastal Waterway, Stuart, Martin County, FL

  13. 3. VAL CONTROL STATION, VIEW OF CONTROL PANELS SHOWING MAIN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VAL CONTROL STATION, VIEW OF CONTROL PANELS SHOWING MAIN PRESSURE GAUGES, LOOKING NORTH. - Variable Angle Launcher Complex, Control Station, CA State Highway 39 at Morris Reservior, Azusa, Los Angeles County, CA

  14. Structural cost optimization of photovoltaic central power station modules and support structure

    NASA Technical Reports Server (NTRS)

    Sutton, P. D.; Stolte, W. J.; Marsh, R. O.

    1979-01-01

    The results of a comprehensive study of photovoltaic module structural support concepts for photovoltaic central power stations and their associated costs are presented. The objective of the study has been the identification of structural cost drivers. Parametric structural design and cost analyses of complete array systems consisting of modules, primary support structures, and foundations were performed. Area related module cost was found to be constant with design, size, and loading. A curved glass module concept was evaluated and found to have the potential to significantly reduce panel structural costs. Conclusions of the study are: array costs do not vary greatly among the designs evaluated; panel and array costs are strongly dependent on design loading; and the best support configuration is load dependent

  15. 117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    117. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111), LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF HELIUM ON LEFT SIDE OF PANEL; CONTROLS FOR NITROGEN ON RIGHT SIDE OF PANEL (AT RIGHT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. 116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    116. PNEUMATIC SUPPLY PANEL IN CENTER OF VEHICLE MECHANICAL SYSTEMS ROOM (111) OF LSB (BLDG. 770), FACING NORTH. CONTROLS FOR FLOW AND PRESSURE REGULATION OF NITROGEN ON RIGHT SIDE OF PANEL; CONTROLS FOR HELIUM ON LEFT SIDE OF PANEL (AT LEFT EDGE OF PHOTO). - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  17. 44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. DOORS FOR THE UMBILICAL MAST TRENCH RAISED FOR MAINTENANCE POSITION OF 10 DEGREES. LAUNCHER IS RIGHT OF MAST; RAILS PARALLEL TO MAST. CONTROL PANELS LEFT TO RIGHT: ELECTRICAL PANEL, COMMUNICATIONS PANEL, AND MAST CONTROL PANEL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. Modeling and Control of the Redundant Parallel Adjustment Mechanism on a Deployable Antenna Panel

    PubMed Central

    Tian, Lili; Bao, Hong; Wang, Meng; Duan, Xuechao

    2016-01-01

    With the aim of developing multiple input and multiple output (MIMO) coupling systems with a redundant parallel adjustment mechanism on the deployable antenna panel, a structural control integrated design methodology is proposed in this paper. Firstly, the modal information from the finite element model of the structure of the antenna panel is extracted, and then the mathematical model is established with the Hamilton principle; Secondly, the discrete Linear Quadratic Regulator (LQR) controller is added to the model in order to control the actuators and adjust the shape of the panel. Finally, the engineering practicality of the modeling and control method based on finite element analysis simulation is verified. PMID:27706076

  19. 67. DETAIL OF VIDEO CAMERA CONTROL PANEL LOCATED IMMEDIATELY WEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    67. DETAIL OF VIDEO CAMERA CONTROL PANEL LOCATED IMMEDIATELY WEST OF ASSISTANT LAUNCH CONDUCTOR PANEL SHOWN IN CA-133-1-A-66 - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. Syndromic Panel-Based Testing in Clinical Microbiology.

    PubMed

    Ramanan, Poornima; Bryson, Alexandra L; Binnicker, Matthew J; Pritt, Bobbi S; Patel, Robin

    2018-01-01

    The recent development of commercial panel-based molecular diagnostics for the rapid detection of pathogens in positive blood culture bottles, respiratory specimens, stool, and cerebrospinal fluid has resulted in a paradigm shift in clinical microbiology and clinical practice. This review focuses on U.S. Food and Drug Administration (FDA)-approved/cleared multiplex molecular panels with more than five targets designed to assist in the diagnosis of bloodstream, respiratory tract, gastrointestinal, or central nervous system infections. While these panel-based assays have the clear advantages of a rapid turnaround time and the detection of a large number of microorganisms and promise to improve health care, they present certain challenges, including cost and the definition of ideal test utilization strategies (i.e., optimal ordering) and test interpretation. Copyright © 2017 American Society for Microbiology.

  1. The first object oriented monitor for intravenous anesthesia.

    PubMed

    Cantraine, F R; Coussaert, E J

    2000-01-01

    To describe the design and implementation of "INFUSION TOOLBOX," a software tool to control and monitor multiple intravenous drug infusions simultaneously using pharmacokinetic and pharmacodynamic principles. INFUSION TOOLBOX has been designed to present a graphical interface. Object Oriented design was used and the software was implemented using Smalltalk, to run on a PC. Basic tools are available to manage patient, drugs, pumps and reports. These tools are the PatientPanel, the DrugPanel, the PumpPanel and the HistoryPanel. The screen is built dynamically. The panels may be collapsed or closed to avoid a crowded display. We also built control panels such as the Target ControlPanel which calculates the best infusion sequence to bring the drug concentration in the plasma compartment to a preset value. Before drug delivery, the user enters the patient's data, selects a drug, enters its dilution factor and chooses a pharmacokinetic model. The calculated plasma concentration is continually displayed and updated. The anesthetist may ask for the history of the delivery to obtain a graphic report or to add events to the logbook. A panel targeting the effect is used when a pharmacodynamic model is known. Data files for drugs, pumps and surgery are upgradable. By creating a resizeable ControlPanel we enable the anesthetist to display the information he wishes, when he wishes it. The available panels are diverse enough to meet the anesthetist needs; they may be adapted to the drug used, pumps used and surgery. It is the anesthetist who builds dynamically its different control screens. By adopting an evolutionary solution model we have achieved considerable success in building our drug delivery monitor. In addition we have gained valuable insight into the anesthesia information domain that will allow us to further enhance and expand the system.

  2. 24 CFR 3280.802 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... panelboard means a single panel or a group of panel units designed for assembly in the form of a single panel... control of light, heat, or power circuits of small individual as well as aggregate capacity; designed to...) Panelboard means a single panel or group of panel units designed for assembly in the form of a single panel...

  3. Assessment of Marine Coatings at a Central California Static Immersion Test Site

    DTIC Science & Technology

    2016-10-27

    VA 220600-6218 RE: Contract Number N00014-15-1-2321 Assessment of Marine Coatings at a Central California Static Immersion Test Site Principal...Technical Report 05/01/2015 - 07/29/2016 Assessment of Marine Coatings at a Central California Static Immersion Test Site Dean E. Wendt Cal Poly...to test the relationships between the recruitment of fouling organisms to intersite panels and water quality parameters. The static immersion site

  4. 29. MAIN CONTROL ROOM, PANELS WEST OF MAIN CONTROL AREA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. MAIN CONTROL ROOM, PANELS WEST OF MAIN CONTROL AREA, LOOKING SOUTH (LOCATION Q) - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA

  5. 28. MAIN CONTROL ROOM, PANELS WEST OF MAIN CONTROL AREA, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. MAIN CONTROL ROOM, PANELS WEST OF MAIN CONTROL AREA, LOOKING NORTH (LOCATION Q) - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA

  6. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    NASA Technical Reports Server (NTRS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (<200 Hz). The device was applied to control noise transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  7. Re-Active Passive devices for control of noise transmission through a panel

    NASA Astrophysics Data System (ADS)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (<1000 Hz) noise transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (<150 Hz). The actuator was applied to control noise transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  8. Reconfigurable work station for a video display unit and keyboard

    NASA Technical Reports Server (NTRS)

    Shields, Nicholas L. (Inventor); Roe, Fred D., Jr. (Inventor); Fagg, Mary F. (Inventor); Henderson, David E. (Inventor)

    1988-01-01

    A reconfigurable workstation is described having video, keyboard, and hand operated motion controller capabilities. The workstation includes main side panels between which a primary work panel is pivotally carried in a manner in which the primary work panel may be adjusted and set in a negatively declined or positively inclined position for proper forearm support when operating hand controllers. A keyboard table supports a keyboard in such a manner that the keyboard is set in a positively inclined position with respect to the negatively declined work panel. Various adjustable devices are provided for adjusting the relative declinations and inclinations of the work panels, tables, and visual display panels.

  9. Noise control using a plate radiator and an acoustic resonator

    NASA Technical Reports Server (NTRS)

    Pla, Frederic G. (Inventor)

    1996-01-01

    An active noise control subassembly for reducing noise caused by a source (such as an aircraft engine) independent of the subassembly. A noise radiating panel is bendably vibratable to generate a panel noise canceling at least a portion of the source noise. A piezoceramic actuator plate is connected to the panel. A front plate is spaced apart from the panel and the first plate, is positioned generally between the source noise and the panel, and has a sound exit port. A first pair of spaced-apart side walls each generally abut the panel and the front plate so as to generally enclose a front cavity to define a resonator.

  10. 75 FR 39544 - Disease, Disability, and Injury Prevention and Control

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Preparedness and Emergency Response Learning Centers (PERLC) Panel, Request for Applications (RFA) TP10- 1001, Initial Review In... in response to ``Preparedness and Emergency Response Learning Centers (PERLC) Panel, RFA TP10-1001...

  11. Technical Evaluation Report on the Flight Mechanics Panel Symposium on the Flight Mechanics Panel Symposium on Space Vehicle Flight Mechanics (La Mecanique du Vol des Vehicules Spatiaux)

    DTIC Science & Technology

    1990-11-01

    control and including final recovery for a wide range of space vehicles from tethered satellite systems and flexible space structures to the space plane...flight mechanics, members from the Fluid Dynamics Panel, the Guidance and Control Panel, the Propulsion and Energetics Panel and the Structures and... Structures and Materials which should be overcome for a successful realization of a human Space Transportation System in the 21st century. He

  12. 77. Deputy commander's launch control console, fire control panel missing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    77. Deputy commander's launch control console, fire control panel missing at right, south side - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  13. Compact Active Vibration Control System for a Flexible Panel

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H. (Inventor); Cabell, Randolph H. (Inventor); Perey, Daniel F. (Inventor)

    2014-01-01

    A diamond-shaped actuator for a flexible panel has an inter-digitated electrode (IDE) and a piezoelectric wafer portion positioned therebetween. The IDE and/or the wafer portion are diamond-shaped. Point sensors are positioned with respect to the actuator and measure vibration. The actuator generates and transmits a cancelling force to the panel in response to an output signal from a controller, which is calculated using a signal describing the vibration. A method for controlling vibration in a flexible panel includes connecting a diamond-shaped actuator to the flexible panel, and then connecting a point sensor to each actuator. Vibration is measured via the point sensor. The controller calculates a proportional output voltage signal from the measured vibration, and transmits the output signal to the actuator to substantially cancel the vibration in proximity to each actuator.

  14. Looking Northwest at Furnace Control Panels and Gas Control Furnace ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking Northwest at Furnace Control Panels and Gas Control Furnace in Red Room Within Recycle Recovery Building - Hematite Fuel Fabrication Facility, Recycle Recovery Building, 3300 State Road P, Festus, Jefferson County, MO

  15. 17. DETAIL OF CONTROL PANEL FOR FILTER #9: CONTROL SWITCHES ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. DETAIL OF CONTROL PANEL FOR FILTER #9: CONTROL SWITCHES CONTROL BY PERCENTAGE OF VALVE OPENINGS INFLUENT, EFFLUENT, DRAINAGE, BACKWASH AND SURFACE WASH. - F. E. Weymouth Filtration Plant, 700 North Moreno Avenue, La Verne, Los Angeles County, CA

  16. Active/Passive Control of Sound Radiation from Panels using Constrained Layer Damping

    NASA Technical Reports Server (NTRS)

    Gibbs, Gary P.; Cabell, Randolph H.

    2003-01-01

    A hybrid passive/active noise control system utilizing constrained layer damping and model predictive feedback control is presented. This system is used to control the sound radiation of panels due to broadband disturbances. To facilitate the hybrid system design, a methodology for placement of constrained layer damping which targets selected modes based on their relative radiated sound power is developed. The placement methodology is utilized to determine two constrained layer damping configurations for experimental evaluation of a hybrid system. The first configuration targets the (4,1) panel mode which is not controllable by the piezoelectric control actuator, and the (2,3) and (5,2) panel modes. The second configuration targets the (1,1) and (3,1) modes. The experimental results demonstrate the improved reduction of radiated sound power using the hybrid passive/active control system as compared to the active control system alone.

  17. 9. VIEW OF FRANCIS TURBINE, GENERATOR DRIVE SHAFT. NOTE ORIGINAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. VIEW OF FRANCIS TURBINE, GENERATOR DRIVE SHAFT. NOTE ORIGINAL EXCITER AND GENERATOR RHEOSTATS ATOP CONTROL PANEL AT REAR. CONTROL PANEL IS ORIGINAL EXCEPT FOR HORIZONTAL TOP PANEL WITH CLOCK AT LEFT AND SYNCHROSCOPE AT RIGHT, LOOKING EAST - Centerville Hydroelectric System, Powerhouse, Butte Creek, Centerville, Butte County, CA

  18. 76 FR 13567 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adoption of Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... Flat Wood Paneling Surface Coating Processes AGENCY: Environmental Protection Agency (EPA). ACTION... sources covered by EPA's Control Techniques Guidelines (CTG) standards for flat wood paneling surface... Protection (PADEP) submitted to EPA a SIP revision concerning the adoption of the CTG for flat wood paneling...

  19. HUBBLE SPACE TELESCOPE (HST) IMAGERY OF THE 30 DORADUS NEBULA

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Hubble Space Telescope (HST) images of the 30 Doradus Nebula show its remarkable cluster of tightly-packed young stars 160,000 light years from Earth in the large Magellanic cloud galaxy. Panel A is a portion of a image made with the HST Wide Field Planetary Camera (WFPC). WFPC photographed four adjoining sky regions simultaneously which are assembled in this mosaic. Panel B is an enlargement of the central portion of the HST image which was made in violet light. It shows the compact star cluster R136, which consists of very hot and massive young stars. The star images have bright cores that are only 0.1 arc seconds wide, allowing many more stars to be distinguished than in previous ground-based telescopic photos. Panel C is a photograph of the same region as Panel B, obtained with the Max Planck 2.2 meter telescope at the European Southern Observatory in Chile. The star images are 0.6 arc seconds wide. Panel D shows how computer processing of the HST image in Panel B has sharpened its

  20. 24 CFR 3280.802 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... supply. (15) Distribution panelboard means a single panel or a group of panel units designed for assembly...) Panelboard means a single panel or group of panel units designed for assembly in the form of a single panel... treatment of air so as to control simultaneously its temperature, humidity, cleanliness, and distribution to...

  1. A curved piezo-structure model: implications on active structural acoustic control.

    PubMed

    Henry, J K; Clark, R L

    1999-09-01

    Current research in Active Structural Acoustic Control (ASAC) relies heavily upon accurately capturing the application physics associated with the structure being controlled. The application of ASAC to aircraft interior noise requires a greater understanding of the dynamics of the curved panels which compose the skin of an aircraft fuselage. This paper presents a model of a simply supported curved panel with attached piezoelectric transducers. The model is validated by comparison to previous work. Further, experimental results for a simply supported curved panel test structure are presented in support of the model. The curvature is shown to affect substantially the dynamics of the panel, the integration of transducers, and the bandwidth required for structural acoustic control.

  2. Panel fabrication utilizing GaAs solar cells

    NASA Technical Reports Server (NTRS)

    Mardesich, N.

    1984-01-01

    The development of the GaAs solar cells for space applications is described. The activities in the fabrication of GaAs solar panels are outlined. Panels were fabricated while introducing improved quality control, soldering laydown and testing procedures. These panels include LIPS II, San Marco Satellite, and a low concentration panel for Rockwells' evaluation. The panels and their present status are discussed.

  3. 4. "TEST CONDUCTORS PANEL AT TEST STAND 1A, DIRECTORATE OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. "TEST CONDUCTORS PANEL AT TEST STAND 1-A, DIRECTORATE OF MISSILE CAPTIVE TEST, EDWARDS AFB, 15 JAN 58, 3098.58." A photograph of the control room, with seven men watching monitors and instrument panels. Photo no. "3098 58; G-AFFTC 15 JAN 58; Test Conductors Panel T.S. 1-A". - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA

  4. Roof aperture system for selective collection and control of solar energy for building heating, cooling and daylighting

    DOEpatents

    Sanders, William J.; Snyder, Marvin K.; Harter, James W.

    1983-01-01

    The amount of building heating, cooling and daylighting is controlled by at least one pair of solar energy passing panels, with each panel of the pair of panels being exposed to a separate direction of sun incidence. A shutter-shade combination is associated with each pair of panels and the shutter is connected to the shade so that rectilinear movement of the shutter causes pivotal movement of the shade.

  5. Final Environmental Assessment for Decommissioning and Demolition of the Central Heat Plant, GHLN 09-1010B F. E. Warren Air Force Base, Wyoming

    DTIC Science & Technology

    2012-06-01

    could either be accomplished by installing a solar heating panel on the roof of each of the 104 buildings or having a solar photovoltaic array...Prior to 1981 , ACMs were used extensively in plaster, wall board, joint compound, felt material , roofing material , floor tile , mastic, piping...5 5.4. Alternative D-lnstall Solar Heating Panels or Solar Photovoltaic Array ......................... 5 5.5. Alternative E

  6. Active Control of Panel Vibrations Induced by a Boundary Layer Flow

    NASA Technical Reports Server (NTRS)

    Chow, Pao-Liu

    1998-01-01

    In recent years, active and passive control of sound and vibration in aeroelastic structures have received a great deal of attention due to many potential applications to aerospace and other industries. There exists a great deal of research work done in this area. Recent advances in the control of sound and vibration can be found in the several conference proceedings. In this report we will summarize our research findings supported by the NASA grant NAG-1-1175. The problems of active and passive control of sound and vibration has been investigated by many researchers for a number of years. However, few of the articles are concerned with the sound and vibration with flow-structure interaction. Experimental and numerical studies on the coupling between panel vibration and acoustic radiation due to flow excitation have been done by Maestrello and his associates at NASA/Langley Research Center. Since the coupled system of nonlinear partial differential equations is formidable, an analytical solution to the full problem seems impossible. For this reason, we have to simplify the problem to that of the nonlinear panel vibration induced by a uniform flow or a boundary-layer flow with a given wall pressure distribution. Based on this simplified model, we have been able to study the control and stabilization of the nonlinear panel vibration, which have not been treated satisfactorily by other authors. The vibration suppression will clearly reduce the sound radiation power from the panel. The major research findings will be presented in the next three sections. In Section II we shall describe our results on the boundary control of nonlinear panel vibration, with or without flow excitation. Section III is concerned with active control of the vibration and sound radiation from a nonlinear elastic panel. A detailed description of our work on the parametric vibrational control of nonlinear elastic panel will be presented in Section IV. This paper will be submitted to the Journal of Acoustic Society of America for publication.

  7. Hybrid Active/Passive Control of Sound Radiation from Panels with Constrained Layer Damping and Model Predictive Feedback Control

    NASA Technical Reports Server (NTRS)

    Cabell, Randolph H.; Gibbs, Gary P.

    2000-01-01

    There has been considerable interest over the past several years in applying feedback control methods to problems of structural acoustics. One problem of particular interest is the control of sound radiation from aircraft panels excited on one side by a turbulent boundary layer (TBL). TBL excitation appears as many uncorrelated sources acting on the panel, which makes it difficult to find a single reference signal that is coherent with the excitation. Feedback methods have no need for a reference signal, and are thus suited to this problem. Some important considerations for the structural acoustics problem include the fact that the required controller bandwidth can easily extend to several hundred Hertz, so a digital controller would have to operate at a few kilohertz. In addition, aircraft panel structures have a reasonably high modal density over this frequency range. A model based controller must therefore handle the modally dense system, or have some way to reduce the bandwidth of the problem. Further complicating the problem is the fact that the stiffness and dynamic properties of an aircraft panel can vary considerably during flight due to altitude changes resulting in significant resonant frequency shifts. These considerations make the tradeoff between robustness to changes in the system being controlled and controller performance especially important. Recent papers concerning the design and implementation of robust controllers for structural acoustic problems highlight the need to consider both performance and robustness when designing the controller. While robust control methods such as H1 can be used to balance performance and robustness, their implementation is not easy and requires assumptions about the types of uncertainties in the plant being controlled. Achieving a useful controller design may require many tradeoff studies of different types of parametric uncertainties in the system. Another approach to achieving robustness to plant changes is to make the controller adaptive. For example, a mathematical model of the plant could be periodically updated as the plant changes, and the feedback gains recomputed from the updated model. To be practical, this approach requires a simple plant model that can be updated quickly with reasonable computational requirements. A recent paper by the authors discussed one way to simplify a feedback controller, by reducing the number of actuators and sensors needed for good performance. The work was done on a tensioned aircraft-style panel excited on one side by TBL flow in a low speed wind tunnel. Actuation was provided by a piezoelectric (PZT) actuator mounted on the center of the panel. For sensing, the responses of four accelerometers, positioned to approximate the response of the first radiation mode of the panel, were summed and fed back through the controller. This single input-single output topology was found to have nearly the same noise reduction performance as a controller with fifteen accelerometers and three PZT patches. This paper extends the previous results by looking at how constrained layer damping (CLD) on a panel can be used to enhance the performance of the feedback controller thus providing a more robust and efficient hybrid active/passive system. The eventual goal is to use the CLD to reduce sound radiation at high frequencies, then implement a very simple, reduced order, low sample rate adaptive controller to attenuate sound radiation at low frequencies. Additionally this added damping smoothes phase transitions over the bandwidth which promotes robustness to natural frequency shifts. Experiments were conducted in a transmission loss facility on a clamped-clamped aluminum panel driven on one side by a loudspeaker. A generalized predictive control (GPC) algorithm, which is suited to online adaptation of its parameters, was used in single input-single output and multiple input-single output configurations. Because this was a preliminary look at the potential constrained layer damping for adaptive control, static feedback control with no online adaptation was used. Two configurations of CLD in addition to a bare panel configuration were studied. For each CLD configuration, two sensor arrangements for the feedback controller were compared. The first arrangement used fifteen accelerometers on the panel to estimate the responses of the first six radiation modes of the panel. The second sensor arrangement was simpler, using the summed responses of only four accelerometers to approximate the response of the first radiation mode of the panel. In all cases a PZT patch was mounted at the center of the panel for control input. The performance of the controller was quantified using the responses of the fifteen accelerometers on the panel to estimate radiated sound power. The paper begins with a brief discussion of the GPC algorithm and the experimental setup. The experimental results are discussed next, comparing the CLD and sensor configurations, followed by discussion and conclusions.

  8. Polyptych Construction as Historical Methodology: An Intertextual Approach to the Stories of Central Technical School's Past

    ERIC Educational Resources Information Center

    Garnet, Dustin

    2015-01-01

    Adopting the lens of "new histories" as the basis for my inquiry into the institutional legacy of the art program at Toronto's Central Technical School (CTS), I created a methodological framework informed by the traditional art form of the polyptych, in which many panels are joined together to show and tell multilayered stories connected…

  9. Noise transmission from a curved panel into a cylindrical enclosure: analysis of structural acoustic coupling.

    PubMed

    Henry, J K; Clark, R L

    2001-04-01

    Much of the research on sound transmission through the aircraft fuselage into the interior of aircraft has considered coupling of the entire cylinder to the acoustic modes of the enclosure. Yet, much of the work on structural acoustic control of sound radiation has focused on reducing sound radiation from individual panels into an acoustic space. Research by the authors seeks to bridge this gap by considering the transmission of sound from individual panels on the fuselage to the interior of the aircraft. As part of this research, an analytical model of a curved panel, with attached piezoelectric actuators, subjected to a static pressure load was previously developed. In the present work, the analytical model is extended to consider the coupling of a curved panel to the interior acoustics of a rigid-walled cylinder. Insight gained from an accurate analytical model of the dynamics of the noise transmission from the curved panels of the fuselage into the cylindrical enclosure of an aircraft is essential to the development of feedback control systems for the control of stochastic inputs, such as turbulent boundary layer excitation. The criteria for maximal structural acoustic coupling between the modes of the curved panel and the modes of the cylindrical enclosure are studied. For panels with aspect ratios typical of those found in aircraft, results indicate that predominately axial structural modes couple most efficiently to the acoustic modes of the enclosure. The effects of the position of the curved panel on the cylinder are also studied. Structural acoustic coupling is found to not be significantly affected by varying panel position. The impact of the findings of this study on structural acoustic control design is discussed.

  10. 44. DETAIL VIEW OF CONTROL PANEL IN UPPER WEST WALL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. DETAIL VIEW OF CONTROL PANEL IN UPPER WEST WALL CONTROL STATION, LOOKING EAST. UPPER INTERMEDIATE WALL AND UPPER EAST WALL CONTROL STATIONS IN BACKGROUND - Upper Mississippi River 9-Foot Channel Project, Lock & Dam 27, Granite City, Madison County, IL

  11. Dual-mode switching of a liquid crystal panel for viewing angle control

    NASA Astrophysics Data System (ADS)

    Baek, Jong-In; Kwon, Yong-Hoan; Kim, Jae Chang; Yoon, Tae-Hoon

    2007-03-01

    The authors propose a method to control the viewing angle of a liquid crystal (LC) panel using dual-mode switching. To realize both wide viewing angle (WVA) characteristics and narrow viewing angle (NVA) characteristics with a single LC panel, the authors use two different dark states. The LC layer can be aligned homogeneously parallel to the transmission axis of the bottom polarizer for WVA dark state operation, while it can be aligned vertically for NVA dark state operation. The authors demonstrated that viewing angle control can be achieved with a single panel without any loss of contrast at the front.

  12. Effect of central obscuration on the LDR point spread function

    NASA Technical Reports Server (NTRS)

    Vanzyl, Jakob J.

    1988-01-01

    It is well known that Gaussian apodization of an aperture reduces the sidelobe levels of its point spread function (PSF). In the limit where the standard deviation of the Gaussian function is much smaller than the diameter of the aperture, the sidelobes completely disappear. However, when Gaussian apodization is applied to the Large Deployable Reflector (LDR) array consisting of 84 hexagonal panels, it is found that the sidelobe level only decreases by about 2.5 dB. The reason for this is explained. The PSF is shown for an array consisting of 91 uniformly illuminated hexagonal apertures; this array is identical to the LDR array, except that the central hole in the LDR array is filled with seven additional panels. For comparison, the PSF of the uniformly illuminated LDR array is shown. Notice that it is already evident that the sidelobe structure of the LDR array is different from that of the full array of 91 panels. The PSF's of the same two arrays are shown, but with the illumination apodized with a Gaussian function to have 20 dB tapering at the edges of the arrays. While the sidelobes of the full array have decreased dramatically, those of the LDR array changed in structure, but stayed at almost the same level. This result is not completely surprising, since the Gaussian apodization tends to emphasize the contributions from the central portion of the array; exactly where the hole in the LDR array is located. The two most important conclusions are: the size of the central hole should be minimized, and a simple Gaussian apodization scheme to suppress the sidelobes in the PSF should not be used. A more suitable apodization scheme would be a Gaussian annular ring.

  13. Experimental Study of the Bending Properties and Deformation Analysis of Web-Reinforced Composite Sandwich Floor Slabs with Four Simply Supported Edges.

    PubMed

    Qi, Yujun; Fang, Hai; Liu, Weiqing

    2016-01-01

    Web-reinforced composite sandwich panels exhibit good mechanical properties in one-way bending, but few studies have investigated their flexural behavior and deformation calculation methods under conditions of four simply supported edges. This paper studies the bending performance of and deformation calculation methods for two-way web-reinforced composite sandwich panels with different web spacing and heights. Polyurethane foam, two-way orthogonal glass-fiber woven cloth and unsaturated resin were used as raw materials in this study. Vacuum infusion molding was used to prepare an ordinary composite sandwich panel and 5 web-reinforced composite sandwich panels with different spacing and web heights. The panels were subjected to two-way panel bending tests with simple support for all four edges. The mechanical properties of these sandwich panels during the elastic stage were determined by applying uniformly distributed loads. The non-linear mechanical characteristics and failure modes were obtained under centrally concentrated loading. Finally, simulations of the sandwich panels, which used the mechanical model established herein, were used to deduce the formulae for the deflection deformation for this type of sandwich panel. The experimental results show that webs can significantly improve the limit bearing capacity and flexural rigidity of sandwich panels, with smaller web spacing producing a stronger effect. When the web spacing is 75 mm, the limit bearing capacity is 4.63 times that of an ordinary sandwich panel. The deduced deflection calculation formulae provide values that agree well with the measurements (maximum error <15%). The results that are obtained herein can provide a foundation for the structural design of this type of panel.

  14. Experimental Study of the Bending Properties and Deformation Analysis of Web-Reinforced Composite Sandwich Floor Slabs with Four Simply Supported Edges

    PubMed Central

    Qi, Yujun; Fang, Hai; Liu, Weiqing

    2016-01-01

    Web-reinforced composite sandwich panels exhibit good mechanical properties in one-way bending, but few studies have investigated their flexural behavior and deformation calculation methods under conditions of four simply supported edges. This paper studies the bending performance of and deformation calculation methods for two-way web-reinforced composite sandwich panels with different web spacing and heights. Polyurethane foam, two-way orthogonal glass-fiber woven cloth and unsaturated resin were used as raw materials in this study. Vacuum infusion molding was used to prepare an ordinary composite sandwich panel and 5 web-reinforced composite sandwich panels with different spacing and web heights. The panels were subjected to two-way panel bending tests with simple support for all four edges. The mechanical properties of these sandwich panels during the elastic stage were determined by applying uniformly distributed loads. The non-linear mechanical characteristics and failure modes were obtained under centrally concentrated loading. Finally, simulations of the sandwich panels, which used the mechanical model established herein, were used to deduce the formulae for the deflection deformation for this type of sandwich panel. The experimental results show that webs can significantly improve the limit bearing capacity and flexural rigidity of sandwich panels, with smaller web spacing producing a stronger effect. When the web spacing is 75 mm, the limit bearing capacity is 4.63 times that of an ordinary sandwich panel. The deduced deflection calculation formulae provide values that agree well with the measurements (maximum error <15%). The results that are obtained herein can provide a foundation for the structural design of this type of panel. PMID:26871435

  15. 45 CFR 170.205 - Content exchange standards and implementation specifications for exchanging electronic health...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... The Healthcare Information Technology Standards Panel (HITSP) Summary Documents Using HL7 CCD... specifications. Implementation Guide for Ambulatory Healthcare Provider Reporting to Central Cancer Registries...

  16. Acoustic plane waves normally incident on a clamped panel in a rectangular duct. [to explain noise reduction curves for reducing interior noise in aircraft

    NASA Technical Reports Server (NTRS)

    Unz, H.; Roskam, J.

    1979-01-01

    The theory of acoustic plane wave normally incident on a clamped panel in a rectangular duct is developed. The coupling theory between the elastic vibrations of the panel (plate) and the acoustic wave propagation in infinite space and in the rectangular duct is considered. The partial differential equation which governs the vibration of the panel (plate) is modified by adding to its stiffness (spring) forces and damping forces, and the fundamental resonance frequency and the attenuation factor are discussed. The noise reduction expression based on the theory is found to agree well with the corresponding experimental data of a sample aluminum panel in the mass controlled region, the damping controlled region, and the stiffness controlled region. All the frequency positions of the upward and downward resonance spikes in the sample experimental data are identified theoretically as resulting from four cross interacting major resonance phenomena: the cavity resonance, the acoustic resonance, the plate resonance, and the wooden back panel resonance.

  17. Remission is the goal for cardiovascular risk management in patients with rheumatoid arthritis: a cross-sectional comparative study.

    PubMed

    Provan, Sella A; Semb, Anne Grete; Hisdal, Jonny; Stranden, Einar; Agewall, Stefan; Dagfinrud, Hanne; Angel, Kristin; Atar, Dan; Kvien, Tore K

    2011-05-01

    To compare markers of cardiovascular disease (CVD) risk between patients with rheumatoid arthritis (RA) in an active disease state and those with RA in remission, and to compare both groups with community controls. 113 patients with RA and 86 community controls were assessed across a panel of biomarkers for CVD. RA in remission was defined as Clinical Disease Activity Index ≤2.8. Community controls were selected at random by Statistics Norway, and controls were matched with patients in the cohorts in strata using details of age, sex and residential area. A panel of biomarkers (N-terminal pro-brain natriuretic peptide (NT-proBNP), total cholesterol, reactive hyperaemia index (RHI), pressure measurements, measures of arterial stiffness and intima-media thickness) were compared between patients with active RA and those with RA in remission. Both groups were compared with controls. In addition, biomarker levels were compared across subgroups based on anticyclic citrullinated peptide status, level of joint destruction and presence of extra-articular manifestations. Patients with active RA had significantly higher levels of NT-proBNP, brachial systolic pressure, augmentation index and central systolic pressure but lower cholesterol than patients in remission and controls. In addition, patients with active RA had significantly higher levels of pulse wave velocity and worse RHI than patients in remission. Comparison across other subgroups gave less consistent differentiations in levels of CVD risk markers. Patients with active RA, but not those in remission, had significantly increased levels of CVD risk markers. These results link inflammatory activity to markers of CVD risk in patients with RA and may indirectly support the notion that remission in RA confers diminished cardiovascular morbidity.

  18. KSC-04pd2029

    NASA Image and Video Library

    2004-09-30

    KENNEDY SPACE CENTER, FLA. - A closeup of the Vehicle Assembly Building shows one of the scaffolds being used to allow workers to cover the holes with corrugated steel so the facility can be returned to performing operational activities. Xenon lights on the ground provide the illumination. The VAB lost 820 panels from the south wall during Frances, and 25 additional panels during Hurricane Jeanne. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, was battered by four hurricanes between Aug. 13 and Sept. 26.

  19. KSC-04pd2026

    NASA Image and Video Library

    2004-09-30

    KENNEDY SPACE CENTER, FLA. - The south wall of the Vehicle Assembly Building is bathed in light at night to allow workers on a scaffold to cover the holes with corrugated steel so the facility can be returned to performing operational activities. Xenon lights on the ground provide the illumination. The VAB lost 820 panels from the south wall during Frances, and 25 additional panels during Hurricane Jeanne. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, was battered by four hurricanes between Aug. 13 and Sept. 26.

  20. KSC-04pd2025

    NASA Image and Video Library

    2004-09-30

    KENNEDY SPACE CENTER, FLA. - Xenon lights on the ground near the Vehicle Assembly Building bathe the south wall in light, allowing workers on scaffolds (center and upper right near the NASA logo) to cover the holes with corrugated steel so the facility can be returned to performing operational activities. The VAB lost 820 panels from the south wall during Frances, and 25 additional panels during Hurricane Jeanne. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, was battered by four hurricanes between Aug. 13 and Sept. 26.

  1. KSC-04PD-2025

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. Xenon lights on the ground near the Vehicle Assembly Building bathe the south wall in light, allowing workers on scaffolds (center and upper right near the NASA logo) to cover the holes with corrugated steel so the facility can be returned to performing operational activities. The VAB lost 820 panels from the south wall during Frances, and 25 additional panels during Hurricane Jeanne. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, was battered by four hurricanes between Aug. 13 and Sept. 26.

  2. 29. INTERIOR VIEW TO THE NORTHEAST OF CONTROL PANEL AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. INTERIOR VIEW TO THE NORTHEAST OF CONTROL PANEL AND VIEWING WINDOW IN ROOM 105, THE CONTROL ROOM. - Nevada Test Site, Pluto Facility, Disassembly Building, Area 26, Wahmonie Flats, Cane Spring Road, Mercury, Nye County, NV

  3. Performance experiments with alternative advanced teleoperator control modes for a simulated solar maximum satellite repair

    NASA Technical Reports Server (NTRS)

    Das, H.; Zak, H.; Kim, W. S.; Bejczy, A. K.; Schenker, P. S.

    1992-01-01

    Experiments are described which were conducted at the JPL Advanced Teleoperator Lab to demonstrate and evaluate the effectiveness of various teleoperator control modes in the performance of a simulated Solar Max Satellite Repair (SMSR) task. THe SMSR was selected as a test because it is very rich in performance capability requirements and it actually has been performed by two EVA astronauts in the Space Shuttle Bay in 1984. The main subtasks are: thermal blanket removal; installation of a hinge attachment for electrical panel opening; opening of electrical panel; removal of electrical connectors; relining of cable bundles; replacement of electrical panel; securing parts and cables; re-mate electrical connectors; closing of electrical panel; and reinstating thermal blanket. The current performance experiments are limited to thermal blanket cutting, electrical panel unbolting and handling electrical bundles and connectors. In one formal experiment even different control modes were applied to the unbolting and reinsertion of electrical panel screws subtasks. The seven control modes are alternative combinations of manual position and rate control with force feedback and remote compliance referenced to force-torque sensor information. Force-torque sensor and end effector position data and task completion times were recorded for analysis and quantification of operator performance.

  4. Active control of panel vibrations induced by a boundary layer flow

    NASA Technical Reports Server (NTRS)

    Chow, Pao-Liu

    1995-01-01

    The problems of active and passive control of sound and vibration has been investigated by many researchers for a number of years. However, few of the articles are concerned with the sound and vibration with flow-structure interaction. Experimental and numerical studies on the coupling between panel vibration and acoustic radiation due to flow excitation have been done by Maestrello and his associates at NASA/Langley Research Center. Since the coupled system of nonlinear partial differential equations is formidable, an analytical solution to the full problem seems impossible. For this reason, we have to simplify the problem to that of the nonlinear panel vibration induced by a uniform flow or a boundary-layer flow with a given wall pressure distribution. Based on this simplified model, we have been able to consider the control and stabilization of the nonlinear panel vibration, which have not been treated satisfactorily by other authors. Although the sound radiation has not been included, the vibration suppression will clearly reduce the sound radiation power from the panel. The major research findings are presented in three sections. In section two we describe results on the boundary control of nonlinear panel vibration, with or without flow excitation. Sections three and four are concerned with some analytical and numerical results in the optimal control of the linear and nonlinear panel vibrations, respectively, excited by the flow pressure fluctuations. Finally, in section five, we draw some conclusions from research findings.

  5. Causal feedforward control of a stochastically excited fuselage structure with active sidewall panel.

    PubMed

    Misol, Malte; Haase, Thomas; Monner, Hans Peter; Sinapius, Michael

    2014-10-01

    This paper provides experimental results of an aircraft-relevant double panel structure mounted in a sound transmission loss facility. The primary structure of the double panel system is excited either by a stochastic point force or by a diffuse sound field synthesized in the reverberation room of the transmission loss facility. The secondary structure, which is connected to the frames of the primary structure, is augmented by actuators and sensors implementing an active feedforward control system. Special emphasis is placed on the causality of the active feedforward control system and its implications on the disturbance rejection at the error sensors. The coherence of the sensor signals is analyzed for the two different disturbance excitations. Experimental results are presented regarding the causality, coherence, and disturbance rejection of the active feedforward control system. Furthermore, the sound transmission loss of the double panel system is evaluated for different configurations of the active system. A principal result of this work is the evidence that it is possible to strongly influence the transmission of stochastic disturbance sources through double panel configurations by means of an active feedforward control system.

  6. Reduction of turbulent boundary layer induced interior noise through active impedance control.

    PubMed

    Remington, Paul J; Curtis, Alan R D; Coleman, Ronald B; Knight, J Scott

    2008-03-01

    The use of a single actuator tuned to an optimum impedance to control the sound power radiated from a turbulent boundary layer (TBL) excited aircraft panel into the aircraft interior is examined. An approach to calculating the optimum impedance is defined and the limitations on the reduction in radiated power by a single actuator tuned to that impedance are examined. It is shown that there are too many degrees of freedom in the TBL and in the radiation modes of the panel to allow a single actuator to control the radiated power. However, if the panel modes are lightly damped and well separated in frequency, significant reductions are possible. The implementation of a controller that presents a desired impedance to a structure is demonstrated in a laboratory experiment, in which the structure is a mass. The performance of such a controller on an aircraft panel is shown to be effective, if the actuator impedance is similar to but not the same as the desired impedance, provided the panel resonances are well separated in frequency and lightly damped.

  7. Application of a Broadband Active Vibration Control System to a Helicopter Trim Panel

    NASA Technical Reports Server (NTRS)

    Cabell, Randolph H.; Schiller, Noah H.; Simon, Frank

    2013-01-01

    This paper discusses testing of a broadband active vibration control concept on an interior trim panel in a helicopter cabin mockup located at ONERA's Centre de Toulouse. The control system consisted of twelve diamond-shaped piezoelectric actuators distributed around a 1.2m x 1.2m trim panel. Accelerometers were mounted at the four vertices of each diamond. The aspect ratio of the diamond was based on the dielectric constants of the piezoelectric material in order to create an actuator-sensor pair that was collocated over a broad frequency range. This allowed robust control to be implemented using simple, low power analog electronics. Initial testing on a thick acrylic window demonstrated the capability of the controller, but actuator performance was less satisfactory when mounted on a composite sandwich trim panel. This may have been due to the orthotropic nature of the trim panel, or due to its much higher stiffness relative to the acrylic window. Insights gained from a finite element study of the actuator-sensor-structural system are discussed.

  8. 75 FR 78998 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Addressing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Addressing Global TB Prevention and Control in all Populations and Strengthening Health Facilities, Laboratories, Prisons and Other...

  9. 32 CFR 1907.03 - Contact for general information and requests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., Agency Release Panel, Central Intelligence Agency, Washington, DC 20505. The commercial (non-secure... INTELLIGENCE AGENCY CHALLENGES TO CLASSIFICATION OF DOCUMENTS BY AUTHORIZED HOLDERS PURSUANT TO § 1.9 OF...

  10. 45 CFR 170.205 - Content exchange standards and implementation specifications for exchanging electronic health...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    .... The Healthcare Information Technology Standards Panel (HITSP) Summary Documents Using HL7 CCD... Guide for Ambulatory Healthcare Provider Reporting to Central Cancer Registries, HL7 Clinical Document...

  11. The influence of land urbanization on landslides: An empirical estimation based on Chinese provincial panel data.

    PubMed

    Li, Gerui; Lei, Yalin; Yao, Huajun; Wu, Sanmang; Ge, Jianping

    2017-10-01

    This study used panel data for 28 provinces and municipalities in China from 2003 to 2014 to investigate the relationship between land urbanization and landslides by building panel models for a national sample and subsamples from the three regions of China and studied the problems of landslide prevention measures based on the relationship. The results showed that 1) at the national level, the percentage of built-up area and road density are respectively negative and positive for landslides. 2) At the regional level, the improvement of landslide prevention measures with increasing economic development only appears in built-up areas. The percentage of built-up areas increases the number of landslides in the western region and decreases the number in the central and eastern regions; the degree of decrease in the eastern region is larger than in the central region. Road density increases the number of landslides in each region, and the degree increases gradually from the west to the east. 3) The effect of landslide prevention funding is not obvious. Although the amount of landslide prevention funds decreases the number of landslides at the national level, the degree of increase is too small. Except in the central region, the amount of landslide prevention funding did not decrease the number of landslides effectively in the western and eastern regions. We propose a series of policy implications based on these test results that may help to improve landslide prevention measures. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. JANNAF Rocket Nozzle Technology Subcommittee Executive Committee Report

    NASA Technical Reports Server (NTRS)

    Lawrence, Timothy W.; Munafo, Paul M. (Technical Monitor)

    2002-01-01

    This viewgraph presentation provides information on the structure and activities of the panels of the Joint Army Navy NASA Air Force (JANNAF) Rocket Nozzle Technology Subcommittee. The panels profiled are the Processing Science and Materials Panel, the Nozzle Design, Test, and Evaluation Panel, the Nozzle Analysis and Modeling Panel, and the Nozzle Control Systems Panel. The presentation also lists meetings, workshops, and publications in which the subcommittee participated during the reporting period.

  13. Shuttle Orbiter Atmospheric Revitalization Pressure Control Subsystem

    NASA Technical Reports Server (NTRS)

    Walleshauser, J. J.; Ord, G. R.; Prince, R. N.

    1982-01-01

    The Atmospheric Revitalization Pressure Control Subsystem (ARPCS) provides oxygen partial pressure and total pressure control for the habitable atmosphere of the Shuttle for either a one atmosphere environment or an emergency 8 PSIA mode. It consists of a Supply Panel, Control Panel, Cabin Pressure Relief Valves and Electronic Controllers. The panels control and monitor the oxygen and nitrogen supplies. The cabin pressure relief valves protect the habitable environment from overpressurization. Electronic controllers provide proper mixing of the two gases. This paper describes the ARPCS, addresses the changes in hardware that have occurred since the inception of the program; the performance of this subsystem during STS-1 and STS-2; and discusses future operation modes.

  14. 50. DETAIL OF TYPICAL PANELS IN ANALOG RECORD BAY. LEFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. DETAIL OF TYPICAL PANELS IN ANALOG RECORD BAY. LEFT PANEL CONTAINS OSCILLOGRAPH AND CONTROLS. RIGHT PANEL CONTAINS CATHODE RAY TUBE AND INK-TYPE CHART RECORDER. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  15. PBF Control Building (PER619). Interior of control room. Control console ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Control Building (PER-619). Interior of control room. Control console in center of room. Indicator panels along walls. Window shown in ID-33-F-120 is between control panels at left. Camera facing northwest. Date: May 2004. INEEL negative no. HD-41-7-3 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  16. The ACT transport: Panacea for the 80's or designer's illusion (panel discussion)

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A panel discussion was held which attempted to make an objective and pragmatic assessment of the standing of active control technology. The discussion focused on the standing of active control technology relative to civil air transport applications, the value as opposed to the cost of the projected benefits, the need for research, development, and demonstration, the role of government and industry in developing the technology, the major obstacles to its implementation, and the probable timing of the full utilization of active control technology in commercial transportation. An edited transcription of the prepared statements of the panel members and the subsequent open discussion between the panel and the audience is presented.

  17. New modeling method and mechanism analyses for active control of interior noise in an irregular enclosure using piezoelectric actuators.

    PubMed

    Geng, Hou C; Rao, Zhu S; Han, Zu S

    2003-03-01

    A new modeling method is developed in this paper for the active minimization of noise within a three-dimensional irregular enclosure using distributed lead zirconate titanate piezoelectric (PZT) actuators, and the control mechanisms for irregular enclosure are analyzed. The irregular enclosure is modeled with four rigid walls and two simply supported flexible panels, and PZT actuators are bound to one of the flexible panels. The process of the new modeling method is as follows. First, the modal coupling method is used to establish the motion equations, which contain important coefficients such as modal masses and modal coupling coefficients, etc., of acoustic-structural-piezoelectric coupling system. Then, the acoustic modes and the modal masses of irregular enclosure are calculated by numerical methods. Last, the modal coupling coefficients in motion equations are calculated according to the numerical results of the acoustic modes of irregular enclosure and the modes of two panels. The validity of this modeling method is verified by a regular hexahedron enclosure. Two cost functions are applied to this model. With the two cost functions, good results are obtained in minimizing the sound-pressure level (SPL) within irregular enclosure according to numerical investigations. By comparing the results obtained under controlled and uncontrolled states, the control mechanisms of the system are discussed. It is found that the control mechanisms vary with disturbance frequencies. At most disturbance frequencies, the SPL within enclosure is reduced by restructuring the modes of two panels simultaneously. When the disturbance frequency comes close to one of the natural frequencies of panel a, the dominant mode of panel a is suppressed, while the modes of panel b are reconstructed. While the disturbance frequency is near one of the natural frequencies of panel b, the modes of two panels are restructured at the same time.

  18. Implantable hemodynamic monitoring (the Chronicle IHM system): remote telemonitoring for patients with heart failure.

    PubMed

    Ho, C

    2008-01-01

    (1) Remote monitoring for ambulatory heart failure patients uses an implantable device to record hemodynamic data and transmit it to a central server for continuous assessment. (2) Preliminary evidence from observational studies suggests a potential for reducing hospitalizations with the use of right ventricle implantable hemodynamic monitoring (IHM). However, although a multicentre, randomized controlled trial (COMPASS-HF) showed a reduction in hospitalizations in the IHM group the results were not statistically significant and the US Food and Drug Administration panel concluded the trial failed to meet its primary efficacy endpoint. (3) In the COMPASS-HF study the most common device-related complication was lead dislodgement. (4) Large randomized controlled trials are needed to demonstrate the clinical utility of IHM, particularly in terms of its impact on reducing hospitalization and improving patient outcomes.

  19. Building with stress-skin panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bliss, S.

    1983-10-01

    A promising new technique for constructing homes that employs stress-skin panels is described. In this method, the insulation, drywall, and sheathing are hung in a single panel. The panels are made in 4 x 8 ft. and up and are either laminated or foamed in place. Both processes require strict manufacturing controls.

  20. Report of the panel on the land surface: Process of change, section 5

    NASA Technical Reports Server (NTRS)

    Adams, John B.; Barron, Eric E.; Bloom, Arthur A.; Breed, Carol; Dohrenwend, J.; Evans, Diane L.; Farr, Thomas T.; Gillespie, Allan R.; Isaks, B. L.; Williams, Richard S.

    1991-01-01

    The panel defined three main areas of study that are central to the Solid Earth Science (SES) program: climate interactions with the Earth's surface, tectonism as it affects the Earth's surface and climate, and human activities that modify the Earth's surface. Four foci of research are envisioned: process studies with an emphasis on modern processes in transitional areas; integrated studies with an emphasis on long term continental climate change; climate-tectonic interactions; and studies of human activities that modify the Earth's surface, with an emphasis on soil degradation. The panel concluded that there is a clear requirement for global coverage by high resolution stereoscopic images and a pressing need for global topographic data in support of studies of the land surface.

  1. 32 CFR 1907.26 - Notification of decision and prohibition on adverse action.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... made to the Interagency Security Classification Appeals Panel (ISCAP) established pursuant to § 5.4 of... CENTRAL INTELLIGENCE AGENCY CHALLENGES TO CLASSIFICATION OF DOCUMENTS BY AUTHORIZED HOLDERS PURSUANT TO Â...

  2. 32 CFR 1907.26 - Notification of decision and prohibition on adverse action.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... made to the Interagency Security Classification Appeals Panel (ISCAP) established pursuant to § 5.4 of... CENTRAL INTELLIGENCE AGENCY CHALLENGES TO CLASSIFICATION OF DOCUMENTS BY AUTHORIZED HOLDERS PURSUANT TO Â...

  3. 4. INGERSOLLRAND AMMONIA COMPRESSOR AND CONTROL PANEL INSIDE BUILDING 2; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. INGERSOLL-RAND AMMONIA COMPRESSOR AND CONTROL PANEL INSIDE BUILDING 2; LOOKING SOUTHWEST - Rath Packing Company, Engine Room, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA

  4. View northeast of a microchip based computer control system installed ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View northeast of a microchip based computer control system installed in the early 1980's to replace Lamokin Tower, at center of photograph; panels 1 and 2 at right of photograph are part of main supervisory board; panel 1 controlled Allen Lane sub-station #7; responsiblity for this portion of the system was transferred to southeast Pennsylvania transit authority (septa) in 1985; panel 2 at extreme right controls catenary switches in a coach storage yard adjacent to the station - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA

  5. 75 FR 43993 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Patient Protection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Patient Protection and Affordable Care Act (PPACA), Emerging Infections Program (EIP), Enhancing Epidemiology and Laboratory Capacity...

  6. 75 FR 52356 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: National Human...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: National Human Immunodeficiency Virus (HIV) Behavioral Surveillance, Funding Opportunity Announcement PS11-001; Initial Review Correction...

  7. A double-panel active segmented partition module using decoupled analog feedback controllers: numerical model.

    PubMed

    Sagers, Jason D; Leishman, Timothy W; Blotter, Jonathan D

    2009-06-01

    Low-frequency sound transmission has long plagued the sound isolation performance of lightweight partitions. Over the past 2 decades, researchers have investigated actively controlled structures to prevent sound transmission from a source space into a receiving space. An approach using active segmented partitions (ASPs) seeks to improve low-frequency sound isolation capabilities. An ASP is a partition which has been mechanically and acoustically segmented into a number of small individually controlled modules. This paper provides a theoretical and numerical development of a single ASP module configuration, wherein each panel of the double-panel structure is independently actuated and controlled by an analog feedback controller. A numerical model is developed to estimate frequency response functions for the purpose of controller design, to understand the effects of acoustic coupling between the panels, to predict the transmission loss of the module in both passive and active states, and to demonstrate that the proposed ASP module will produce bidirectional sound isolation.

  8. IET. Control room in control building (TAN620). Terminal panels for ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Control room in control building (TAN-620). Terminal panels for instrumentation wiring. Note alarm horn and emergency light at right edge of view. Cable reel comes from Collier, Pawtucket, RI. Date: February 1955. INEEL negative no. 55-362 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  9. Factors Affecting Regional Per-Capita Carbon Emissions in China Based on an LMDI Factor Decomposition Model

    PubMed Central

    Dong, Feng; Long, Ruyin; Chen, Hong; Li, Xiaohui; Yang, Qingliang

    2013-01-01

    China is considered to be the main carbon producer in the world. The per-capita carbon emissions indicator is an important measure of the regional carbon emissions situation. This study used the LMDI factor decomposition model–panel co-integration test two-step method to analyze the factors that affect per-capita carbon emissions. The main results are as follows. (1) During 1997, Eastern China, Central China, and Western China ranked first, second, and third in the per-capita carbon emissions, while in 2009 the pecking order changed to Eastern China, Western China, and Central China. (2) According to the LMDI decomposition results, the key driver boosting the per-capita carbon emissions in the three economic regions of China between 1997 and 2009 was economic development, and the energy efficiency was much greater than the energy structure after considering their effect on restraining increased per-capita carbon emissions. (3) Based on the decomposition, the factors that affected per-capita carbon emissions in the panel co-integration test showed that Central China had the best energy structure elasticity in its regional per-capita carbon emissions. Thus, Central China was ranked first for energy efficiency elasticity, while Western China was ranked first for economic development elasticity. PMID:24353753

  10. Factors affecting regional per-capita carbon emissions in China based on an LMDI factor decomposition model.

    PubMed

    Dong, Feng; Long, Ruyin; Chen, Hong; Li, Xiaohui; Yang, Qingliang

    2013-01-01

    China is considered to be the main carbon producer in the world. The per-capita carbon emissions indicator is an important measure of the regional carbon emissions situation. This study used the LMDI factor decomposition model-panel co-integration test two-step method to analyze the factors that affect per-capita carbon emissions. The main results are as follows. (1) During 1997, Eastern China, Central China, and Western China ranked first, second, and third in the per-capita carbon emissions, while in 2009 the pecking order changed to Eastern China, Western China, and Central China. (2) According to the LMDI decomposition results, the key driver boosting the per-capita carbon emissions in the three economic regions of China between 1997 and 2009 was economic development, and the energy efficiency was much greater than the energy structure after considering their effect on restraining increased per-capita carbon emissions. (3) Based on the decomposition, the factors that affected per-capita carbon emissions in the panel co-integration test showed that Central China had the best energy structure elasticity in its regional per-capita carbon emissions. Thus, Central China was ranked first for energy efficiency elasticity, while Western China was ranked first for economic development elasticity.

  11. Impact-damaged graphite-thermoplastic trapezoidal-corrugation sandwich and semi-sandwich panels

    NASA Technical Reports Server (NTRS)

    Jegley, D.

    1993-01-01

    The results of a study of the effects of impact damage on compression-loaded trapezoidal-corrugation sandwich and semi-sandwich graphite-thermoplastic panels are presented. Sandwich panels with two identical face sheets and a trapezoidal corrugated core between them, and semi-sandwich panels with a corrugation attached to a single skin are considered in this study. Panels were designed, fabricated and tested. The panels were made using the manufacturing process of thermoforming, a less-commonly used technique for fabricating composite parts. Experimental results for unimpacted control panels and panels subjected to impact damage prior to loading are presented. Little work can be found in the literature about these configurations of thermoformed panels.

  12. Submerged combustion melting processes for producing glass and similar materials, and systems for carrying out such processes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charbonneau, Mark William

    Processes of controlling submerged combustion melters, and systems for carrying out the methods. One process includes feeding vitrifiable material into a melter vessel, the melter vessel including a fluid-cooled refractory panel in its floor, ceiling, and/or sidewall, and heating the vitrifiable material with a burner directing combustion products into the melting zone under a level of the molten material in the zone. Burners impart turbulence to the molten material in the melting zone. The fluid-cooled refractory panel is cooled, forming a modified panel having a frozen or highly viscous material layer on a surface of the panel facing the moltenmore » material, and a sensor senses temperature of the modified panel using a protected thermocouple positioned in the modified panel shielded from direct contact with turbulent molten material. Processes include controlling the melter using the temperature of the modified panel. Other processes and systems are presented.« less

  13. 75 FR 4406 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational Safety and Health Training Projects Grants, Request for Applications (RFA) 06-484; and Occupational Safety and Health Educational...

  14. 75 FR 77645 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy Risk Assessment... initial review, discussion, and evaluation of ``Pregnancy Risk Assessment Monitoring System (PRAMS), DP11...

  15. 75 FR 13769 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Natural...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Natural Experiments and... meeting will include the initial review, discussion, and evaluation of ``Natural Experiments and...

  16. 60. Shock isolator at center, pneumatic control group panel at ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Shock isolator at center, pneumatic control group panel at left, power distribution box at right, all at right of entrance to lcc. - Ellsworth Air Force Base, Delta Flight, Launch Control Facility, County Road CS23A, North of Exit 127, Interior, Jackson County, SD

  17. 75 FR 28810 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Addressing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-24

    ... evaluation of applications received in response to ``Addressing Emerging Infectious Diseases and Related... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Addressing Emerging Infectious...

  18. 77 FR 25180 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Evaluation of Dengue Epidemiology, Outcomes, and Prevention in Sentinel...

  19. 78 FR 15015 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review The meeting announced below concerns Epidemiology, Prevention and Treatment of Influenza and other Respiratory...

  20. 78 FR 28221 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Youth Violence Training and Technical Assistance, Funding Opportunity Announcement...

  1. 75 FR 76987 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Epidemiologic and Ecologic... evaluation of applications received in response to ``Epidemiologic and Ecologic Determinants of Monkeypox in...

  2. 76 FR 19995 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-11

    ..., Extramural Research Program Office, National Center for Chronic Disease Prevention and Health Promotion, CDC... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding Opportunity Announcement...

  3. View looking straightup at celing in center of entrance portico ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View looking straight-up at celing in center of entrance portico showing stenciled and painted panel saying "C.R.R. 1856." - Central of Georgia Railway, Gray Building, 227 West Broad Street, Savannah, Chatham County, GA

  4. Wireless Protection.

    ERIC Educational Resources Information Center

    Conforti, Fred

    2003-01-01

    Discusses wireless access-control equipment in the school and university setting, particularly the integrated reader lock at the door with a panel interface module at the control panel. Describes its benefits, how it works, and its reliability and security. (EV)

  5. Geostationary Space Launch Vehicles and the U.S. Dilemma

    DTIC Science & Technology

    1994-06-17

    solar panels for power generation and no attitude control system for orbit stabilization. The communications circuits were underpowered because the... solar panels were small compared to the ones used on GEO satellites today. Although the lack of attitude control systems greatly reduced the weight of...to ten year useful life has been realized using good fuel management techniques. The size of the solar panels on GEO satellites have been the

  6. Tow-Steered Panels With Holes Subjected to Compression or Shear Loads

    NASA Technical Reports Server (NTRS)

    Jegley, Dawn C.; Tatting, Brian F.; Guerdal, Zafer

    2005-01-01

    Tailoring composite laminates to vary the fiber orientations within a fiber layer of a laminate to address non-uniform stress states and provide structural advantages such as the alteration of principal load paths has potential application to future low-cost, light-weight structures for commercial transport aircraft. Evaluation of this approach requires the determination of the effectiveness of stiffness tailoring through the use of curvilinear fiber paths in flat panels including the reduction of stress concentrations around the holes and the increase in load carrying capability. Panels were designed through the use of an optimization code using a genetic algorithm and fabricated using a tow-steering approach. Manufacturing limitations, such as the radius of curvature of tows the machine could support, avoidance of wrinkling of fibers and minimization of gaps between fibers were considered in the design process. Variable stiffness tow-steered panels constructed with curvilinear fiber paths were fabricated so that the design methodology could be verified through experimentation. Finite element analysis where each element s stacking sequence was accurately defined is used to verify the behavior predicted based on the design code. Experiments on variable stiffness flat panels with central circular holes were conducted with the panels loaded in axial compression or shear. Tape and tow-steered panels are used to demonstrate the buckling, post-buckling and failure behavior of elastically tailored panels. The experimental results presented establish the buckling performance improvements attainable by elastic tailoring of composite laminates.

  7. Two-Dimensional Sequential and Concurrent Finite Element Analysis of Unstiffened and Stiffened Aluminum and Composite Panels with Hole

    NASA Technical Reports Server (NTRS)

    Razzaq, Zia; Prasad, Venkatesh

    1988-01-01

    The results of a detailed investigation of the distribution of stresses in aluminum and composite panels subjected to uniform end shortening are presented. The focus problem is a rectangular panel with two longitudinal stiffeners, and an inner stiffener discontinuous at a central hole in the panel. The influence of the stiffeners on the stresses is evaluated through a two-dimensional global finite element analysis in the absence or presence of the hole. Contrary to the physical feel, it is found that the maximum stresses from the glocal analysis for both stiffened aluminum and composite panels are greater than the corresponding stresses for the unstiffened panels. The inner discontinuous stiffener causes a greater increase in stresses than the reduction provided by the two outer stiffeners. A detailed layer-by-layer study of stresses around the hole is also presented for both unstiffened and stiffened composite panels. A parallel equation solver is used for the global system of equations since the computational time is far less than that using a sequential scheme. A parallel Choleski method with up to 16 processors is used on Flex/32 Multicomputer at NASA Langley Research Center. The parallel computing results are summarized and include the computational times, speedups, bandwidths, and their inter-relationships for the panel problems. It is found that the computational time for the Choleski method decreases with a decrease in bandwidth, and better speedups result as the bandwidth increases.

  8. KSC-04pd2027

    NASA Image and Video Library

    2004-09-30

    KENNEDY SPACE CENTER, FLA. - The south wall of the Vehicle Assembly Building is bathed in light at night to allow workers on a scaffold (at left) to cover the holes with corrugated steel so the facility can be returned to performing operational activities. Xenon lights on the ground provide the illumination. The VAB lost 820 panels from the south wall during Frances, and 25 additional panels during Hurricane Jeanne. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, was battered by four hurricanes between Aug. 13 and Sept. 26.

  9. Laminar flow control SPF/08 feasibility demonstration

    NASA Astrophysics Data System (ADS)

    Ecklund, R. C.; Williams, N. R.

    1981-10-01

    The feasibility of applying superplastic forming/diffusion bonding (SPF/DB) technology to laminar flow control (LFC) system concepts was demonstrated. Procedures were developed to produce smooth, flat titanium panels, using thin -0.016 inch sheets, meeting LFC surface smoothness requirements. Two large panels 28 x 28 inches were fabricated as final demonstration articles. The first was flat on the top and bottom sides demonstrating the capability of the tooling and the forming and diffusion bonding procedures to produce flat, defect free surfaces. The second panel was configurated for LFC porous panel treatment by forming channels with dimpled projections on the top side. The projections were machined away leaving holes extending into the panel. A perforated titanium sheet was adhesively bonded over this surface to complete the LFC demonstration panel. The final surface was considered flat enough to meet LFC requirements for a jet transport aircraft in cruising flight.

  10. 75 FR 9606 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Public...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Public Health Research on... in response to ``Public Health Research on Craniofacial Malformation, FOA DP 10-001.'' Contact Person...

  11. 77 FR 3269 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention (CDC) Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Data Coordinating Center for Autism and Other Developmental Disabilities Research and Epidemiologic Studies, RFA DD12-001, Initial...

  12. 75 FR 78999 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Centers for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Centers for Autism and... evaluation of ``Centers for Autism and Developmental Disabilities Research and Epidemiology (CADDRE), FOA...

  13. 77 FR 12844 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Reducing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Reducing Health Disparities Among... to ``Reducing Health Disparities among People with Intellectual Disabilities, FOA DD12-003, initial...

  14. 77 FR 291 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns National HIV Behavioral Surveillance For Young Men Who Have Sex With Men, Funding...

  15. 76 FR 27327 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Virologic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Virologic Evaluation of the Modes of Influenza Virus Transmission Among Humans, Funding Opportunity Announcement, IP11-001 Correction...

  16. 76 FR 13621 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family History and Diamond Blackfan Anemia, DD11- 010, Initial Review Correction: This notice was published in the Federal Register on...

  17. 76 FR 12122 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): The...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): The Association of Genetic Biomarkers and Hereditary Hemochromatosis, DD11-008, Initial Review Correction: This notice was published in...

  18. 76 FR 3908 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): The...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): The Association of Genetic... meeting will include the initial review, discussion, and evaluation of ``The Association of Genetic...

  19. 25. LOOKING SOUTH AT THE MAIN CONTROL PANEL FOR BASIC ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. LOOKING SOUTH AT THE MAIN CONTROL PANEL FOR BASIC OXYGEN FURNACE No. 1 IN THE BOP SHOP'S No. 1 CONTROL ROOM ON THE OPERATING FLOOR OF THE FURNACE AISLE. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  20. 26. LOOKING SOUTH AT THE MOTOR CONTROL SWITCHING PANEL FOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. LOOKING SOUTH AT THE MOTOR CONTROL SWITCHING PANEL FOR BASIC OXYGEN FURNACE No. 2 IN THE BOP SHOP'S MOTOR CONTROL CENTER No. 2 ON THE GROUND FLOOR OF THE FURNACE AISLE. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  1. 76 FR 10908 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal Vitamin D Status and....D., Scientific Review Officer, CDC, National Center for Chronic Disease Prevention and Health...

  2. 75 FR 7281 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Translating...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Translating Research Into Action... of the Director, Extramural Research Program Office, 4770 Buford Highway, NE., Mailstop K-92, Atlanta...

  3. 75 FR 9423 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Impact of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Impact of Japanese Encephalitis... to ``Impact of Japanese Encephalitis Vaccination in Cambodia, FOA CK10-003.'' Contact Person for More...

  4. 75 FR 69686 - Disease, Disability, and Injury Prevention and Control; Special Emphasis Panel: Epi-Centers for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-15

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control; Special Emphasis Panel: Epi-Centers for the Prevention of... following: Place: 12 Executive Park Drive, Atlanta, Georgia 30333. Contact Person for More Information...

  5. 77 FR 16232 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): A Pilot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): A Pilot Surveillance for High... in response to ``A Pilot Surveillance for High Impact/Low Prevalence Congenital and Inherited...

  6. 75 FR 29561 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance, Natural History, Quality of Care and Outcomes of Diabetes Mellitus with Onset in Childhood and Adolescence, RFA DP 10-001...

  7. 76 FR 13414 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pilot...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pilot Longitudinal Data Collection To Inform Public Health--Fragile X Syndrome, DD11-007, Initial Review Notice of Cancellation: This...

  8. 15. View northeast of main control panels, Arctic and Tropic ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. View northeast of main control panels, Arctic and Tropic Chambers, in machine area. - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  9. 133. NITROGEN SUPPLY PANEL ON SOUTH WALL OF CONTROL ROOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    133. NITROGEN SUPPLY PANEL ON SOUTH WALL OF CONTROL ROOM (114), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. Astronaut Charles Conrad Jr. working with control panel in Skylab simulation

    NASA Image and Video Library

    1973-02-01

    S73-16765 (1 Feb. 1973) --- Astronaut Charles Conrad Jr. is seen working with the control panels of the Skylab Orbital Workshop trainer during Skylab training at the Johnson Space Center. Photo credit: NASA

  11. Indicator system for advanced nuclear plant control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  12. Indicator system for a process plant control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  13. Console for a nuclear control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  14. Alarm system for a nuclear control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  15. Method of installing a control room console in a nuclear power plant

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1994-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  16. Advanced nuclear plant control complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  17. Advanced nuclear plant control room complex

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  18. Vibro-acoustic model of an active aircraft cabin window

    NASA Astrophysics Data System (ADS)

    Aloufi, Badr; Behdinan, Kamran; Zu, Jean

    2017-06-01

    This paper presents modeling and design of an active structural acoustic control (ASAC) system for controlling the low frequency sound field transmitted through an aircraft cabin window. The system uses stacked piezoelectric elements arranged in a manner to generate out-of-plane actuation point forces acting on the window panel boundaries. A theoretical vibro-acoustic model for an active quadruple-panel system is developed to characterize the dynamic behavior of the system and achieve a good understanding of the active control performance and the physical phenomena of the sound transmission loss (STL) characteristics. The quadruple-panel system represents the passenger window design used in some classes of modern aircraft with an exterior double pane of Plexiglas, an interior dust cover pane and a glazed dimmable pane, all separated by thin air cavities. The STL characteristics of identical pane window configurations with different piezoelectric actuator sets are analyzed. A parametric study describes the influence of important active parameters, such as the input voltage, number and location of the actuator elements, on the STL is investigated. In addition, a mathematical model for obtaining the optimal input voltage is developed to improve the acoustic attenuation capability of the control system. In general, the achieved results indicate that the proposed ASAC design offers a considerable improvement in the passive sound loss performance of cabin window design without significant effects, such as weight increase, on the original design. Also, the results show that the acoustic control of the active model with piezoelectric actuators bonded to the dust cover pane generates high structural vibrations in the radiating panel (dust cover) and an increase in sound power radiation. High active acoustic attenuation can be achieved by designing the ASAC system to apply active control forces on the inner Plexiglas panel or dimmable panel by installing the actuators on the boundaries of one of the two panels. In some cases, increasing the actuator numbers in the structure advances the active control performance by controlling more structural modes; however, this decreases the STL of the passive control system because of the increase in structure-borne sound transmission paths of the stiffer piezoelectric actuators.

  19. A point-of-care chemistry test for reduction of turnaround and clinical decision time.

    PubMed

    Lee, Eui Jung; Shin, Sang Do; Song, Kyoung Jun; Kim, Seong Chun; Cho, Jin Seong; Lee, Seung Chul; Park, Ju Ok; Cha, Won Chul

    2011-06-01

    Our study compared clinical decision time between patients managed with a point-of-care chemistry test (POCT) and patients managed with the traditional central laboratory test (CLT). This was a randomized controlled multicenter trial in the emergency departments (EDs) of 5 academic teaching hospitals. We randomly assigned patients to POCT or CLT stratified by the Emergency Severity Index. A POCT chemistry analyzer (Piccolo; Abaxis, Inc, Union City, Calif), which is able to test liver panel, renal panel, pancreas enzymes, lipid panel, electrolytes, and blood gases, was set up in each ED. Primary and secondary end point was turnaround time and door-to-clinical-decision time. The total 2323 patients were randomly assigned to the POCT group (n = 1167) or to the CLT group (n = 1156). All of the basic characteristics were similar in the 2 groups. The turnaround time (median, interquartile range [IQR]) of the POCT group was shorter than that of the CLT group (14, 12-19 versus 55, 45-69 minutes; P < .0001). The median (IQR) door-to-clinical-decision time was also shorter in the POCT compared with the CLT group (46, 33-61 versus 86, 68-107 minutes; P < .0001). The proportion of patients who had new decisions within 60 minutes was 72.8% for the POCT group and 12.5% for the CLT group (P < .0001). A POCT chemistry analyzer in the ED shortens the test turnaround and ED clinical decision times compared with CLT. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Manual and automatic flight control during severe turbulence penetration

    NASA Technical Reports Server (NTRS)

    Johnston, D. E.; Klein, R. H.; Hoh, R. H.

    1976-01-01

    An analytical and experimental investigation of possible contributing factors in jet aircraft turbulence upsets was conducted. Major contributing factors identified included autopilot and display deficiencies, the large aircraft inertia and associated long response time, and excessive pilot workload. An integrated flight and thrust energy management director system was synthesized. The system was incorporated in a moving-base simulation and evaluated using highly experienced airline pilots. The evaluation included comparison of pilot workload and flight performance during severe turbulence penetration utilizing four control/display concepts: manual control with conventional full panel display, conventional autopilot (A/P-A) with conventional full panel display, improved autopilot (A/P-B) with conventional full panel display plus thrust director display, and longitudinal flight director with conventional full panel display plus thrust director display. Simulation results show improved performance, reduced pilot workload, and a pilot preference for the autopilot system controlling to the flight director command and manual control of thrust following the trim thrust director.

  1. STS-28 Columbia, OV-102, Pilot Richards at forward flight deck pilots station

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Pilot Richard N. Richards, sitting at forward flight deck pilots station controls, looks back to aft flight deck during STS-28, a Department of Defense (DOD) dedicated mission. Control panels F7 and F8 and portable laptop computer propped on panel F4 appear in front of Richards. Behind him are the pilots seat seat back and head rest. A stuffed toy animal is positioned on C1 panel.

  2. 76 FR 28441 - Center for Scientific Review; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ...: Vision, Cognition and Pain. Date: June 29-30, 2011. Time: 8 a.m. to 6 p.m. Agenda: To review and evaluate...: Center for Scientific Review Special Emphasis Panel; Member Conflict: Cognition and Central Visual...

  3. 3. VIEW NORTH, SOUTHWEST FRONT, SOUTHEAST SIDE Front and side ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. VIEW NORTH, SOUTHWEST FRONT, SOUTHEAST SIDE Front and side elevation. Note gasoline sign post added. Flush store window not altered, 1900 clapboard siding and panelling remaining. - 510 Central Avenue (Commercial Building), Ridgely, Caroline County, MD

  4. [The relic in the Panels of São Vicente de Fora].

    PubMed

    Goyri-O'Neill, João; Camisão-Soares, Artur; Neves Marques, Cláudia

    2013-01-01

    The Panels of São Vicente de Fora, a polyptych dated from 1470 to 1480, are a work composed of 6 panels, authored by Nuno Gonçalves, a painter of King Afonso V. This work reveals one of the most remarkable collective portraits of European painting, making this polyptych an inexhaustible source of readings and interpretations, fueling a secular controversy. The present work aims analyzing precise an iconographic anatomical image repainted in the 6th panel, or the panel of the Relic. This consists of a central image within a structure shown by a red figure with special reverence. The investigation conducted and justification was based on direct observation and comparative analysis of iconographic data collected in the Museum of Antique Art. The bone pieces were selected at the Museum of Anatomy, Department of Anatomy, Faculty of Medical Sciences, New University of Lisbon, and the comparative analyses performed by two observers, with further analysis of the images obtained in the National Museum of Ancient Art using specific software. After watching these, it was concluded that this representation of a relic in the Panels of São Vicente is an iconic representation of an Occipital bone, fractured at its lower edge, being evident, almost complete, its vertical portion or scale.

  5. Germ-line and somatic EPHA2 coding variants in lens aging and cataract.

    PubMed

    Bennett, Thomas M; M'Hamdi, Oussama; Hejtmancik, J Fielding; Shiels, Alan

    2017-01-01

    Rare germ-line mutations in the coding regions of the human EPHA2 gene (EPHA2) have been associated with inherited forms of pediatric cataract, whereas, frequent, non-coding, single nucleotide variants (SNVs) have been associated with age-related cataract. Here we sought to determine if germ-line EPHA2 coding SNVs were associated with age-related cataract in a case-control DNA panel (> 50 years) and if somatic EPHA2 coding SNVs were associated with lens aging and/or cataract in a post-mortem lens DNA panel (> 48 years). Micro-fluidic PCR amplification followed by targeted amplicon (exon) next-generation (deep) sequencing of EPHA2 (17-exons) afforded high read-depth coverage (1000x) for > 82% of reads in the cataract case-control panel (161 cases, 64 controls) and > 70% of reads in the post-mortem lens panel (35 clear lens pairs, 22 cataract lens pairs). Novel and reference (known) missense SNVs in EPHA2 that were predicted in silico to be functionally damaging were found in both cases and controls from the age-related cataract panel at variant allele frequencies (VAFs) consistent with germ-line transmission (VAF > 20%). Similarly, both novel and reference missense SNVs in EPHA2 were found in the post-mortem lens panel at VAFs consistent with a somatic origin (VAF > 3%). The majority of SNVs found in the cataract case-control panel and post-mortem lens panel were transitions and many occurred at di-pyrimidine sites that are susceptible to ultraviolet (UV) radiation induced mutation. These data suggest that novel germ-line (blood) and somatic (lens) coding SNVs in EPHA2 that are predicted to be functionally deleterious occur in adults over 50 years of age. However, both types of EPHA2 coding variants were present at comparable levels in individuals with or without age-related cataract making simple genotype-phenotype correlations inconclusive.

  6. Germ-line and somatic EPHA2 coding variants in lens aging and cataract

    PubMed Central

    Bennett, Thomas M.; M’Hamdi, Oussama; Hejtmancik, J. Fielding

    2017-01-01

    Rare germ-line mutations in the coding regions of the human EPHA2 gene (EPHA2) have been associated with inherited forms of pediatric cataract, whereas, frequent, non-coding, single nucleotide variants (SNVs) have been associated with age-related cataract. Here we sought to determine if germ-line EPHA2 coding SNVs were associated with age-related cataract in a case-control DNA panel (> 50 years) and if somatic EPHA2 coding SNVs were associated with lens aging and/or cataract in a post-mortem lens DNA panel (> 48 years). Micro-fluidic PCR amplification followed by targeted amplicon (exon) next-generation (deep) sequencing of EPHA2 (17-exons) afforded high read-depth coverage (1000x) for > 82% of reads in the cataract case-control panel (161 cases, 64 controls) and > 70% of reads in the post-mortem lens panel (35 clear lens pairs, 22 cataract lens pairs). Novel and reference (known) missense SNVs in EPHA2 that were predicted in silico to be functionally damaging were found in both cases and controls from the age-related cataract panel at variant allele frequencies (VAFs) consistent with germ-line transmission (VAF > 20%). Similarly, both novel and reference missense SNVs in EPHA2 were found in the post-mortem lens panel at VAFs consistent with a somatic origin (VAF > 3%). The majority of SNVs found in the cataract case-control panel and post-mortem lens panel were transitions and many occurred at di-pyrimidine sites that are susceptible to ultraviolet (UV) radiation induced mutation. These data suggest that novel germ-line (blood) and somatic (lens) coding SNVs in EPHA2 that are predicted to be functionally deleterious occur in adults over 50 years of age. However, both types of EPHA2 coding variants were present at comparable levels in individuals with or without age-related cataract making simple genotype-phenotype correlations inconclusive. PMID:29267365

  7. Technological process and optimum design of organic materials vacuum pyrolysis and indium chlorinated separation from waste liquid crystal display panels.

    PubMed

    Ma, En; Xu, Zhenming

    2013-12-15

    In this study, a technology process including vacuum pyrolysis and vacuum chlorinated separation was proposed to convert waste liquid crystal display (LCD) panels into useful resources using self-design apparatuses. The suitable pyrolysis temperature and pressure are determined as 300°C and 50 Pa at first. The organic parts of the panels were converted to oil (79.10 wt%) and gas (2.93 wt%). Then the technology of separating indium was optimized by central composite design (CCD) under response surface methodology (RSM). The results indicated the indium recovery ratio was 99.97% when the particle size is less than 0.16 mm, the weight percentage of NH4Cl to glass powder is 50 wt% and temperature is 450°C. The research results show that the organic materials, indium and glass of LCD panel can be recovered during the recovery process efficiently and eco-friendly. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Steel test panel helps control additives in pyrophosphate copper plating

    NASA Technical Reports Server (NTRS)

    Hollar, W. T.

    1967-01-01

    Test panel helps control maximum tolerance level for plating solution contaminants. It provides low, medium, and high-current density areas such as exist in production plating, and plating is examined for uniformity of texture and ductility.

  9. Automated Intelligent Monitoring and the Controlling Software System for Solar Panels

    NASA Astrophysics Data System (ADS)

    Nalamwar, H. S.; Ivanov, M. A.; Baidali, S. A.

    2017-01-01

    The inspection of the solar panels on a periodic basis is important to improve longevity and ensure performance of the solar system. To get the most solar potential of the photovoltaic (PV) system is possible through an intelligent monitoring & controlling system. The monitoring & controlling system has rapidly increased its popularity because of its user-friendly graphical interface for data acquisition, monitoring, controlling and measurements. In order to monitor the performance of the system especially for renewable energy source application such as solar photovoltaic (PV), data-acquisition systems had been used to collect all the data regarding the installed system. In this paper the development of a smart automated monitoring & controlling system for the solar panel is described, the core idea is based on IoT (the Internet of Things). The measurements of data are made using sensors, block management data acquisition modules, and a software system. Then, all the real-time data collection of the electrical output parameters of the PV plant such as voltage, current and generated electricity is displayed and stored in the block management. The proposed system is smart enough to make suggestions if the panel is not working properly, to display errors, to remind about maintenance of the system through email or SMS, and to rotate panels according to a sun position using the Ephemeral table that stored in the system. The advantages of the system are the performance of the solar panel system which can be monitored and analyzed.

  10. 75 FR 28622 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Conducting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-21

    ... in Kenya (U01)(Panel A), Funding Opportunity Announcement (FOA) GH10-003, Initial Review In... received in response to ``Conducting Public Health Research in Kenya (U01)(Panel A),'' FOA GH10-003...

  11. Currie at RMS controls on the aft flight deck

    NASA Image and Video Library

    1998-12-05

    S88-E-5010 (12-05-98) --- Operating at a control panel on Endeavour's aft flight deck, astronaut Nancy J. Currie works with the robot arm prior to mating the 12.8-ton Unity connecting module to Endeavour's docking system. The mating took place on late afternoon of Dec. 5. A nearby monitor provides a view of the remote manipulator system's (RMS) movements in the cargo bay. The feat marked an important step in assembling the new International Space Station. Manipulating the shuttle's 50-foot-long robot arm, Currie placed Unity just inches above the extended outer ring on Endeavour's docking mechanism, enabling Robert D. Cabana, mission commander to fire downward maneuvering jets, locking the shuttle's docking system to one of two Pressurized Mating Adapters (PMA) attached to Unity. The mating occurred at 5:45 p.m. Central time, as Endeavour sailed over eastern China.

  12. Composites from southern pine juvenile wood. Part 1. Panel fabrication and initial properties

    Treesearch

    Anton D. Pugel; Eddie W. Price; Chung-Yun Hse

    1990-01-01

    Flakeboard, particleboard, and fiberboard panels were manufactured from four different sources of southern pine (Pinus taeda L.) juvenile wood. The sources were: 1) fastgrown trees; 2) the inner core of older trees; 3) branches; and 4) tops. The juvenile wood particle sizes and panel densities were similar to those used for control panels made from...

  13. 75 FR 29350 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Miner Safety...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-25

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Miner Safety and Health Training--Western United States, Request for Application (RFA) OH10-001, Initial Review In accordance with section...

  14. 76 FR 20355 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding Opportunity Announcement (FOA), Initial Review The meeting announced below concerns ``Conducting Public Health Research in Thailand by the Ministry of Public Health (MOPH)...

  15. 76 FR 9785 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Human...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Human Immunodeficiency Virus (HIV) Prevention Projects for Young Men of Color Who Have Sex With Men and Young Transgender Persons of Color...

  16. Symposium on formulation and application of microbials for spruce budworm and gypsy moth control

    Treesearch

    J. A. Armstrong; W. G. Yendol

    1985-01-01

    This panel of experts from Canada and the United States has been brought together to discuss control techniques and strategies employed against these important defoliators - the spruce budworm and the gypsy moth. In selecting the panel we have chosen people with experience ranging from research to control.

  17. 75 FR 26266 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Developing Novel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Developing Novel Diagnostic Tests To Improve Surveillance for Antimicrobial Resistant Pathogens, Funding Opportunity Announcement CI10-002; Initial Review Correction: This notice was...

  18. Local feedback control of light honeycomb panels.

    PubMed

    Hong, Chinsuk; Elliott, Stephen J

    2007-01-01

    This paper summarizes theoretical and experimental work on the feedback control of sound radiation from honeycomb panels using piezoceramic actuators. It is motivated by the problem of sound transmission in aircraft, specifically the active control of trim panels. Trim panels are generally honeycomb structures designed to meet the design requirement of low weight and high stiffness. They are resiliently mounted to the fuselage for the passive reduction of noise transmission. Local coupling of the closely spaced sensor and actuator was observed experimentally and modeled using a single degree of freedom system. The effect of the local coupling was to roll off the response between the actuator and sensor at high frequencies, so that a feedback control system can have high gain margins. Unfortunately, only relatively poor global performance is then achieved because of localization of reduction around the actuator. This localization prompts the investigation of a multichannel active control system. Globalized reduction was predicted using a model of 12-channel direct velocity feedback control. The multichannel system, however, does not appear to yield a significant improvement in the performance because of decreased gain margin.

  19. The use of an active controlled enclosure to attenuate sound radiation from a heavy radiator

    NASA Astrophysics Data System (ADS)

    Sun, Yao; Yang, Tiejun; Zhu, Minggang; Pan, Jie

    2017-03-01

    Active structural acoustical control usually experiences difficulty in the control of heavy sources or sources where direct applications of control forces are not practical. To overcome this difficulty, an active controlled enclosure, which forms a cavity with both flexible and open boundary, is employed. This configuration permits indirect implementation of active control in which the control inputs can be applied to subsidiary structures other than the sources. To determine the control effectiveness of the configuration, the vibro-acoustic behavior of the system, which consists of a top plate with an open, a sound cavity and a source panel, is investigated in this paper. A complete mathematical model of the system is formulated involving modified Fourier series formulations and the governing equations are solved using the Rayleigh-Ritz method. The coupling mechanisms of a partly opened cavity and a plate are analysed in terms of modal responses and directivity patterns. Furthermore, to attenuate sound power radiated from both the top panel and the open, two strategies are studied: minimizing the total radiated power and the cancellation of volume velocity. Moreover, three control configurations are compared, using a point force on the control panel (structural control), using a sound source in the cavity (acoustical control) and applying hybrid structural-acoustical control. In addition, the effects of boundary condition of the control panel on the sound radiation and control performance are discussed.

  20. Digital Full-Scope Simulation of a Conventional Nuclear Power Plant Control Room, Phase 2: Installation of a Reconfigurable Simulator to Support Nuclear Plant Sustainability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronald L. Boring; Vivek Agarwal; Kirk Fitzgerald

    2013-03-01

    The U.S. Department of Energy’s Light Water Reactor Sustainability program has developed a control room simulator in support of control room modernization at nuclear power plants in the U.S. This report highlights the recent completion of this reconfigurable, full-scale, full-scope control room simulator buildout at the Idaho National Laboratory. The simulator is fully reconfigurable, meaning it supports multiple plant models developed by different simulator vendors. The simulator is full-scale, using glasstop virtual panels to display the analog control boards found at current plants. The present installation features 15 glasstop panels, uniquely achieving a complete control room representation. The simulator ismore » also full-scope, meaning it uses the same plant models used for training simulators at actual plants. Unlike in the plant training simulators, the deployment on glasstop panels allows a high degree of customization of the panels, allowing the simulator to be used for research on the design of new digital control systems for control room modernization. This report includes separate sections discussing the glasstop panels, their layout to mimic control rooms at actual plants, technical details on creating a multi-plant and multi-vendor reconfigurable simulator, and current efforts to support control room modernization at U.S. utilities. The glasstop simulator provides an ideal testbed for prototyping and validating new control room concepts. Equally importantly, it is helping create a standardized and vetted human factors engineering process that can be used across the nuclear industry to ensure control room upgrades maintain and even improve current reliability and safety.« less

  1. 129. INTERIOR OF RELAY BOX FOR HYDRAULIC CONTROL PANEL IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    129. INTERIOR OF RELAY BOX FOR HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  2. 124. ACCUMULATORS AT LOWER RIGHT SIDE OF HYDRAULIC CONTROL PANEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    124. ACCUMULATORS AT LOWER RIGHT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. 22. PHOTOCOPY OF PHOTOGRAPH. View north of main control panels, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    22. PHOTOCOPY OF PHOTOGRAPH. View north of main control panels, Artic and Tropic Chambers, ca. 1955. (Source: NRDEC). - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  4. 14. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW TO SOUTH. - Rocky Mountain Arsenal, Cluster Bomb Assembly-Filling-Storage Building, 3500 feet South of Ninth Avenue; 2870 feet East of D Street, Commerce City, Adams County, CO

  5. 17. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW TO SOUTH. - Rocky Mountain Arsenal, Cluster Bomb Assembly-Filling-Storage Building, 3500 feet South of Ninth Avenue; 2870 feet East of D Street, Commerce City, Adams County, CO

  6. 15. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW TO NORTH. - Rocky Mountain Arsenal, Cluster Bomb Assembly-Filling-Storage Building, 3500 feet South of Ninth Avenue; 2870 feet East of D Street, Commerce City, Adams County, CO

  7. 16. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. INTERIOR DETAIL OF CONTROL PANEL IN BUILDING 1606. VIEW TO SOUTHWEST. - Rocky Mountain Arsenal, Cluster Bomb Assembly-Filling-Storage Building, 3500 feet South of Ninth Avenue; 2870 feet East of D Street, Commerce City, Adams County, CO

  8. Decentralized control of sound radiation using iterative loop recovery.

    PubMed

    Schiller, Noah H; Cabell, Randolph H; Fuller, Chris R

    2010-10-01

    A decentralized model-based control strategy is designed to reduce low-frequency sound radiation from periodically stiffened panels. While decentralized control systems tend to be scalable, performance can be limited due to modeling error introduced by the unmodeled interaction between neighboring control units. Since bounds on modeling error are not known in advance, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is evaluated numerically using a model of a stiffened aluminum panel that is representative of the sidewall of an aircraft. Simulations demonstrate that the iterative approach can achieve significant reductions in radiated sound power from the stiffened panel without destabilizing neighboring control units.

  9. Decentralized Control of Sound Radiation Using Iterative Loop Recovery

    NASA Technical Reports Server (NTRS)

    Schiller, Noah H.; Cabell, Randolph H.; Fuller, Chris R.

    2009-01-01

    A decentralized model-based control strategy is designed to reduce low-frequency sound radiation from periodically stiffened panels. While decentralized control systems tend to be scalable, performance can be limited due to modeling error introduced by the unmodeled interaction between neighboring control units. Since bounds on modeling error are not known in advance, it is difficult to ensure the decentralized control system will be robust without making the controller overly conservative. Therefore an iterative approach is suggested, which utilizes frequency-shaped loop recovery. The approach accounts for modeling error introduced by neighboring control loops, requires no communication between subsystems, and is relatively simple. The control strategy is evaluated numerically using a model of a stiffened aluminum panel that is representative of the sidewall of an aircraft. Simulations demonstrate that the iterative approach can achieve significant reductions in radiated sound power from the stiffened panel without destabilizing neighboring control units.

  10. NAS Panel faults export controls

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    A study prepared by a top-level panel says that current export controls on militarily sensitive U.S. technology may be “overcorrecting” previous weaknesses in that system, resulting in “a complex and confusing control system” that makes it more difficult for U.S. businesses to compete in international markets. Moreover, this control system has “an increasingly corrosive effect” on U.S. relations with allies. The panel recommended that the United States concentrate more effort on bringing about uniformity in the export control policies of countries belonging to the Coordinating Committee on Multilateral Export Controls (CoCom), i.e., most of the member nations in NATO (the North Atlantic Treaty Organization) and Japan.The 21-member panel was appointed by the Committee on Science, Engineering, and Public Policy (COSEPUP), a joint unit of the National Academy of Sciences (NAS), the National Academy of Engineering (NAE), and the Institute of Medicine (IOM). The panel, composed of administrators, researchers, and former government officials, was chaired by AGU member Lew Allen, Jr., director of the Jet Propulsion Laboratory (Pasadena, Calif.) and former chief of staff of the U.S. Air Force. Their report was supported by NAS funds, by a number of private organizations (including AGU), by the U.S. Departments of Commerce, Defense, Energy, and State, by the National Science Foundation, and by the National Aeronautics and Space Administration.

  11. Display device for indicating the value of a parameter in a process plant

    DOEpatents

    Scarola, Kenneth; Jamison, David S.; Manazir, Richard M.; Rescorl, Robert L.; Harmon, Daryl L.

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  12. The Outdoor Air Pollution and Brain Health Workshop

    EPA Science Inventory

    Accumulating evidence suggests that air pollution may have a significant impact on central nervous system (CNS) health and disease. To address this issue, the National Institute of Environmental Health Sciences/National Institute of Health convened a panel of research scientists...

  13. Pilot performance and heart rate during in-flight use of a compact instrument display.

    DOT National Transportation Integrated Search

    1975-11-01

    Instrument panels in many general aviation aircraft are becoming increasingly crowded, presenting the pilot with an instrument scanning problem. Because most aircraft instruments require use of central (foveal) vision, the pilot must look directly at...

  14. Empowerment Evaluation: Yesterday, Today, and Tomorrow

    ERIC Educational Resources Information Center

    Fetterman, David; Wandersman, Abraham

    2007-01-01

    Empowerment evaluation continues to crystallize central issues for evaluators and the field of evaluation. A highly attended American Evaluation Association conference panel, titled "Empowerment Evaluation and Traditional Evaluation: 10 Years Later," provided an opportunity to reflect on the evolution of empowerment evaluation. Several…

  15. Dynamic and thermal response finite element models of multi-body space structural configurations

    NASA Technical Reports Server (NTRS)

    Edighoffer, Harold H.

    1987-01-01

    Presented is structural dynamics modeling of two multibody space structural configurations. The first configuration is a generic space station model of a cylindrical habitation module, two solar array panels, radiator panel, and central connecting tube. The second is a 15-m hoop-column antenna. Discussed is the special joint elimination sequence used for these large finite element models, so that eigenvalues could be extracted. The generic space station model aided test configuration design and analysis/test data correlation. The model consisted of six finite element models, one of each substructure and one of all substructures as a system. Static analysis and tests at the substructure level fine-tuned the finite element models. The 15-m hoop-column antenna is a truss column and structural ring interconnected with tension stabilizing cables. To the cables, pretensioned mesh membrane elements were attached to form four parabolic shaped antennae, one per quadrant. Imposing thermal preloads in the cables and mesh elements produced pretension in the finite element model. Thermal preload variation in the 96 control cables was adjusted to maintain antenna shape within the required tolerance and to give pointing accuracy.

  16. Application of a trigonometric finite difference procedure to numerical analysis of compressive and shear buckling of orthotropic panels

    NASA Technical Reports Server (NTRS)

    Stein, M.; Housner, J. D.

    1978-01-01

    A numerical analysis developed for the buckling of rectangular orthotropic layered panels under combined shear and compression is described. This analysis uses a central finite difference procedure based on trigonometric functions instead of using the conventional finite differences which are based on polynomial functions. Inasmuch as the buckle mode shape is usually trigonometric in nature, the analysis using trigonometric finite differences can be made to exhibit a much faster convergence rate than that using conventional differences. Also, the trigonometric finite difference procedure leads to difference equations having the same form as conventional finite differences; thereby allowing available conventional finite difference formulations to be converted readily to trigonometric form. For two-dimensional problems, the procedure introduces two numerical parameters into the analysis. Engineering approaches for the selection of these parameters are presented and the analysis procedure is demonstrated by application to several isotropic and orthotropic panel buckling problems. Among these problems is the shear buckling of stiffened isotropic and filamentary composite panels in which the stiffener is broken. Results indicate that a break may degrade the effect of the stiffener to the extent that the panel will not carry much more load than if the stiffener were absent.

  17. The response of an expert panel to Nutritional armor for the warfighter: can omega-3 fatty acids enhance stress resilience, wellness, and military performance?

    PubMed

    Coulter, Ian D

    2014-11-01

    Recommendations of an Expert Panel on 5 central questions addressed during the workshop. The Panel reviewed available scientific literature, workshop presentations, and comments from workshop guests. The Panel unanimously agreed that a military Daily Recommended Intake for long-chain omega-3 fatty acids (FAs) should be established within the context of lowering current intakes of omega-6 FAs. The Panelists also felt that there was sufficient evidence to support increasing omega-3 intake to receive cardiovascular, immunological, and surgical benefits. In addition, research indicates that preloading with omega-3 FAs before combat exposure may be beneficial. Evidence for reduction of depressive symptoms and suicide prevention was felt to be strong. Insufficient data were available to evaluate post-traumatic stress disorder and impulsive aggression. Benefits for traumatic brain injury were promising. Adverse side effects were deemed negligible. The Panel concluded that based on studies analyzing omega-3 and omega-6 FA balance, it would be unethical to not attempt elevating the omega-3 status among U.S. military personnel. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  18. Complex Mobile Independent Power Station for Urban Areas

    NASA Astrophysics Data System (ADS)

    Tunik, A. A.; Tolstoy, M. Y.

    2017-11-01

    A new type of a complex mobile independent power station developed in the Department of Engineering Communications and Life-Support Systems of Irkutsk National Research Technical University, is presented in this article. This station contains only solar panel, wind turbine, accumulator, diesel generator and microbial fuel cell for to produce electric energy, heat pump and solar collector to generate heat energy and also wastewater treatment plant and new complex control system. The complex mobile independent power station is intended for full power supply of a different kind of consumers located even in remote areas thus reducing their dependence from centralized energy supply systems, decrease the fossil fuel consumption, improve the environment of urban areas and solve the problems of the purification of industrial and municipal wastewater.

  19. The development of an Infrared Environmental System for TOPEX Solar Panel Testing

    NASA Technical Reports Server (NTRS)

    Noller, E.

    1994-01-01

    Environmental testing and flight qualification of the TOPEX/POSEIDON spacecraft solar panels were performed with infrared (IR) lamps and a control system that were newly designed and integrated. The basic goal was more rigorous testing of the costly panels' new composite-structure design without jeopardizing their safety. The technique greatly reduces the costs and high risks of testing flight solar panels.

  20. Network Control Center User Planning System (NCC UPS)

    NASA Astrophysics Data System (ADS)

    Dealy, Brian

    1991-09-01

    NCC UPS is presented in the form of the viewgraphs. The following subject areas are covered: UPS overview; NCC UPS role; major NCC UPS functional requirements; interactive user access levels; UPS interfaces; interactive user subsystem; interface navigation; scheduling screen hierarchy; interactive scheduling input panels; autogenerated schedule request panel; schedule data tabular display panel; schedule data graphic display panel; graphic scheduling aid design; and schedule data graphic display.

  1. Network Control Center User Planning System (NCC UPS)

    NASA Technical Reports Server (NTRS)

    Dealy, Brian

    1991-01-01

    NCC UPS is presented in the form of the viewgraphs. The following subject areas are covered: UPS overview; NCC UPS role; major NCC UPS functional requirements; interactive user access levels; UPS interfaces; interactive user subsystem; interface navigation; scheduling screen hierarchy; interactive scheduling input panels; autogenerated schedule request panel; schedule data tabular display panel; schedule data graphic display panel; graphic scheduling aid design; and schedule data graphic display.

  2. The effect of oblique angle of sound incidence, realistic edge conditions, curvature and in-plane panel stresses on the noise reduction characteristics of general aviation type panels

    NASA Technical Reports Server (NTRS)

    Grosveld, F.; Lameris, J.; Dunn, D.

    1979-01-01

    Experiments and a theoretical analysis were conducted to predict the noise reduction of inclined and curved panels. These predictions are compared to the experimental results with reasonable agreement between theory and experiment for panels under an oblique angle of sound incidence. Theoretical as well as experimental results indicate a big increase in noise reduction when a flat test panel is curved. Further curving the panel slightly decreases the noise reduction. Riveted flat panels are shown to give a higher noise reduction in the stiffness-controlled frequency region, while bonded panels are superior in this region when the test panel is curved. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial in-plane stresses are presented and discussed. These test results indicate an important improvement in the noise reduction of these panels in the frequency range below the fundamental panel/cavity frequency.

  3. Population Genetics of Plasmodium vivax in Four Rural Communities in Central Vietnam

    PubMed Central

    Hong, Nguyen Van; Delgado-Ratto, Christopher; Thanh, Pham Vinh; Van den Eede, Peter; Guetens, Pieter; Binh, Nguyen Thi Huong; Phuc, Bui Quang; Duong, Tran Thanh; Van Geertruyden, Jean Pierre; D’Alessandro, Umberto; Erhart, Annette; Rosanas-Urgell, Anna

    2016-01-01

    Background The burden of malaria in Vietnam has drastically reduced, prompting the National Malaria Control Program to officially engage in elimination efforts. Plasmodium vivax is becoming increasingly prevalent, remaining a major problem in the country's central and southern provinces. A better understanding of P. vivax genetic diversity and structure of local parasite populations will provide baseline data for the evaluation and improvement of current efforts for control and elimination. The aim of this study was to examine the population genetics and structure of P. vivax isolates from four communities in Tra Leng commune, Nam Tra My district in Quang Nam, Central Vietnam. Methodology/Principal Findings P. vivax mono infections collected from 234 individuals between April 2009 and December 2010 were successfully analyzed using a panel of 14 microsatellite markers. Isolates displayed moderate genetic diversity (He = 0.68), with no significant differences between study communities. Polyclonal infections were frequent (71.4%) with a mean multiplicity of infection of 1.91 isolates/person. Low but significant genetic differentiation (FST value from -0.05 to 0.18) was observed between the community across the river and the other communities. Strong linkage disequilibrium (IAS = 0.113, p < 0.001) was detected across all communities, suggesting gene flow within and among them. Using multiple approaches, 101 haplotypes were grouped into two genetic clusters, while 60.4% of haplotypes were admixed. Conclusions/Significance In this area of Central Vietnam, where malaria transmission has decreased significantly over the past decade, there was moderate genetic diversity and high occurrence of polyclonal infections. Local human populations have frequent social and economic interactions that facilitate gene flow and inbreeding among parasite populations, while decreasing population structure. Findings provide important information on parasites populations circulating in the study area and are relevant to current malaria elimination efforts. PMID:26872387

  4. 76 FR 9018 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Emerging...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-16

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Emerging Infections Sentinel... with Section 10(a)(2) of the Federal Advisory Committee Act (Pub. L. 92-463), the Centers for Disease Control and Prevention (CDC), announces the aforementioned meeting: Times and Dates: 12 p.m.-2 p.m., March...

  5. The control panel for the joint NASA/Gulfstream Quiet Spike project, located in the backseat of NASA's F-15B testbed aircraft

    NASA Image and Video Library

    2006-08-16

    The control panel for the joint NASA/Gulfstream Quiet Spike project, located in the backseat of NASA's F-15B testbed aircraft. The project seeks to verify the structural integrity of the multi-segmented, articulating spike attachment designed to reduce and control a sonic boom.

  6. Fracture behavior of large-scale thin-sheet aluminum alloy

    NASA Technical Reports Server (NTRS)

    Dewit, Roland; Fields, Richard J.; Mordfin, Leonard; Low, Samuel R.; Harne, Donald

    1994-01-01

    A series of fracture tests on large-scale, pre-cracked, aluminum alloy panels is being carried out to examine and to characterize the process by which cracks propagate and link up in this material. Extended grips and test fixtures were specially designed to enable the panel specimens to be loaded in tension, in a 1780-kN-capacity universal testing machine. Twelve panel specimens, each consisting of a single sheet of bare 2024-T3 aluminum alloy, 3988 mm high, 2286 mm wide, and 1.016 mm thick are being fabricated with simulated through-cracks oriented horizontally at mid-height. Using existing information, a test matrix has been set up that explores regions of failure that are controlled by fracture mechanics, with additional tests near the boundary between plastic collapse and fracture. In addition, a variety of multiple site damage (MSD) configurations have been included to distinguish between various proposed linkage mechanisms. All tests but one use anti-buckling guides. At this writing seven specimens have been tested. Three were fabricated with a single central crack, three others had multiple cracks on each side of the central crack, and one had a single crack but no anti-buckling guides. Each fracture event was recorded on film, video, computer, magnetic tape, and occasionally optical microscopy. The visual showed the crack tip with a load meter in the field of view, using motion picture film for one tip and SVHS video tape for the other. The computer recorded the output of the testing machine load cell, the stroke, and twelve strain gages at 1.5 second intervals. A wideband FM magnetic tape recorder was used to record data from the same sources. The data were analyzed by two different procedures: (1) the plastic zone model based on the residual strength diagram; and (2) the R-curve. The first three tests were used to determine the basic material properties, and these results were then used in the analysis of the two subsequent tests with MSD cracks. There is good agreement between measured values and results obtained from the model.

  7. Application of a Bimetallic Treatment System (BTS) for PCB Removal from Older Structures on DoD Facilities

    DTIC Science & Technology

    2010-11-05

    the Banana River to the West and mosquito control lagoons to the East. The building components that are to be treated are from inside the structure... peeling /removal) is given. Untreated areas of panel 3 and 4 were tested as a control, to determine the adhesion qualities of the paint prior to...similarly shows untreated panel 4. Both panels (untreated) were scored a 5, indicating no peeling or removal of the paint upon removal of the pressure

  8. Manufacturing Methods and Technology Program Automatic In-Process Microcircuit Evaluation.

    DTIC Science & Technology

    1980-10-01

    methods of controlling the AIME system are with the computer and associated inter- face (CPU control), and with controls located on the front panels...Sync and Blanking signals When the AIME system is being operated by the front panel controls , the computer does not influence the system operation. SU...the color video monitor display. The operator controls these parameters by 1) depressing the appropriate key on the keyboard, 2) observing on the

  9. KSC-04PD-2023

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. On a scaffold barely visible along the south wall of the Vehicle Assembly Building near the NASA logo, workers are covering the holes with corrugated steel so the facility can be returned to performing operational activities. The VAB lost 820 panels from the south wall during the storm, and 25 additional panels pulled off the east wall by Hurricane Jeanne. Another scaffold is suspended near the top of the east wall (right side) for repairs. The VAB stands 525 feet tall. Central Florida, including Kennedy Space Center, has been battered by four hurricanes between Aug. 13 and Sept. 26.

  10. 32 CFR 1907.02 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... means the United States Central Intelligence Agency acting through the CIA Information and Privacy... Information and Privacy Coordinator acting in the capacity of Executive Secretary of the Agency Release Panel... the documents or information at issue; (i) Originator means the CIA officer who originated the...

  11. Material development for laminar flow control wing panels

    NASA Technical Reports Server (NTRS)

    Meade, L. E.

    1977-01-01

    The absence of suitable porous materials or techniques for the economic perforation of surface materials has previously restricted the design of laminar flow control (LFC) wing panels to a consideration of mechanically slotted LFC surfaces. A description is presented of a program which has been conducted to exploit recent advances in materials and manufacturing technology for the fabrication of reliable porous or perforated LFC surface panels compatible with the requirements of subsonic transport aircraft. Attention is given to LFC design criteria, surface materials, surface concepts, the use of microporous composites, perforated composites, and perforated metal. The described program was successful in that fabrication processes were developed for producing predictable perforated panels both of composite and of metal.

  12. Thermal-Diode Sandwich Panel

    NASA Technical Reports Server (NTRS)

    Basiulis, A.

    1986-01-01

    Thermal diode sandwich panel transfers heat in one direction, but when heat load reversed, switches off and acts as thermal insulator. Proposed to control temperature in spacecraft and in supersonic missiles to protect internal electronics. In combination with conventional heat pipes, used in solar panels and other heat-sensitive systems.

  13. Seismicity and geodynamics in the central part of the Vanuatu Arc

    NASA Astrophysics Data System (ADS)

    Baillard, C.; Crawford, W. C.; Ballu, V.; Regnier, M. M.; Pelletier, B.; Garaebiti, E.

    2013-12-01

    The Vanuatu Arc (VA) in the southwest Pacific ocean (167°E, 13-20°S), is highly seismically active, with more than 35 events of magnitude Mw ≥ 7 since 1973 (USGS catalog). The geodynamics are dominated by the east-dipping subduction of the Australian Plate under the North Fiji Basin microplate. Convergence rates are estimated to be between 130 and 170 mm/yr, except in the central part of the VA where convergence slows to 30-40 mm/yr. This slowing appears to be the result of blockage by the subducting d'Entrecastaux ridge. To quantify the tectonics of this blocked section, we deployed 30 seismometers in 2008-2009 and 8 GPS stations since 2008, in the forearc region of the central VA. The seismometers recorded more than 100 events/day. Detailed analysis of the earthquake catalog reveals: 1) a seismic gap between 40 and 60 km deep under the two largest islands of the VA (Santo and Malekula); 2) subduction plane and intraplate faulting within the down-going plate; and 3) reduced activity beneath Malekula island , perhaps indicating a locked patch on the subduction plane. We infer the geometry of the subduction interface by combining our catalog with unpublished data from the 2000 Santo Mw 6.9 earthquake and aftershocks and the USGS and Global CMT catalogs. The subduction interface appears to be composed of two different panels: a shallow one with a small dip angle and a deeper one with higher dip starting at a depth of ~50 km. We compare finite-element modeling of these panels to the geodetic data to test the connectedness of the two panels and their degree of locking.

  14. Treatment strategies in colorectal cancer patients with initially unresectable liver-only metastases, a study protocol of the randomised phase 3 CAIRO5 study of the Dutch Colorectal Cancer Group (DCCG).

    PubMed

    Huiskens, Joost; van Gulik, Thomas M; van Lienden, Krijn P; Engelbrecht, Marc R W; Meijer, Gerrit A; van Grieken, Nicole C T; Schriek, Jonne; Keijser, Astrid; Mol, Linda; Molenaar, I Quintus; Verhoef, Cornelis; de Jong, Koert P; Dejong, Kees H C; Kazemier, Geert; Ruers, Theo M; de Wilt, Johanus H W; van Tinteren, Harm; Punt, Cornelis J A

    2015-05-06

    Colorectal cancer patients with unresectable liver-only metastases may be cured after downsizing of metastases by neoadjuvant systemic therapy. However, the optimal neoadjuvant induction regimen has not been defined, and the lack of consensus on criteria for (un)resectability complicates the interpretation of published results. CAIRO5 is a multicentre, randomised, phase 3 clinical study. Colorectal cancer patients with initially unresectable liver-only metastases are eligible, and will not be selected for potential resectability. The (un)resectability status is prospectively assessed by a central panel consisting of at least one radiologist and three liver surgeons, according to predefined criteria. Tumours of included patients will be tested for RAS mutation status. Patients with RAS wild type tumours will be treated with doublet chemotherapy (FOLFOX or FOLFIRI) and randomised between the addition of either bevacizumab or panitumumab, and patients with RAS mutant tumours will be randomised between doublet chemotherapy (FOLFOX or FOLFIRI) plus bevacizumab or triple chemotherapy (FOLFOXIRI) plus bevacizumab. Radiological evaluation to assess conversion to resectability will be performed by the central panel, at an interval of two months. The primary study endpoint is median progression-free survival. Secondary endpoints are the R0/1 resection rate, median overall survival, response rate, toxicity, pathological response of resected lesions, postoperative morbidity, and correlation of baseline and follow-up evaluation with respect to outcomes by the central panel. CAIRO5 is a prospective multicentre trial that investigates the optimal systemic induction therapy for patients with initially unresectable, liver-only colorectal cancer metastases. CAIRO 5 is registered at European Clinical Trials Database (EudraCT) (2013-005435-24). CAIRO 5 is registered at ClinicalTrials.gov: NCT02162563 , June 10, 2014.

  15. PARAS program: Phased array radio astronomy from space

    NASA Astrophysics Data System (ADS)

    Jakubowski, Antoni K.; Haynes, David A.; Nuss, Ken; Hoffmann, Chris; Madden, Michael; Dungan, Michael

    1992-06-01

    An orbiting radio telescope is proposed which, when operated in a Very Long Baseline Interferometry (VLBLI) scheme, would allow higher (than currently available) angular resolution and dynamic range in the maps, and the ability of observing rapidly changing astronomical sources. Using a passive phases array technology, the proposed design consists of 656 hexagonal modules forming a 150 meter diameter dish. Each observatory module is largely autonomous, having its own photovoltaic power supply and low-noise receiver and processor for phase shifting. The signals received by the modules are channeled via fiber optics to the central control computer in the central bus module. After processing and multiplexing, the data is transmitted to telemetry stations on the ground. The truss frame supporting each observatory pane is a hybrid structure consisting of a bottom graphite/epoxy tubular triangle and rigidized inflatable Kevlar tubes connecting the top observatory panel and bottom triangle. Attitude control and stationkeeping functions are performed by a system of momentum wheels in the bus and four propulsion modules located at the compass points on the periphery of the observatory dish. Each propulsion module has four monopropellant thrusters and six hydrazine arcjets, the latter supported by a nuclear reactor. The total mass of the spacecraft is 22,060 kg.

  16. PARAS program: Phased array radio astronomy from space

    NASA Technical Reports Server (NTRS)

    Jakubowski, Antoni K.; Haynes, David A.; Nuss, Ken; Hoffmann, Chris; Madden, Michael; Dungan, Michael

    1992-01-01

    An orbiting radio telescope is proposed which, when operated in a Very Long Baseline Interferometry (VLBLI) scheme, would allow higher (than currently available) angular resolution and dynamic range in the maps, and the ability of observing rapidly changing astronomical sources. Using a passive phases array technology, the proposed design consists of 656 hexagonal modules forming a 150 meter diameter dish. Each observatory module is largely autonomous, having its own photovoltaic power supply and low-noise receiver and processor for phase shifting. The signals received by the modules are channeled via fiber optics to the central control computer in the central bus module. After processing and multiplexing, the data is transmitted to telemetry stations on the ground. The truss frame supporting each observatory pane is a hybrid structure consisting of a bottom graphite/epoxy tubular triangle and rigidized inflatable Kevlar tubes connecting the top observatory panel and bottom triangle. Attitude control and stationkeeping functions are performed by a system of momentum wheels in the bus and four propulsion modules located at the compass points on the periphery of the observatory dish. Each propulsion module has four monopropellant thrusters and six hydrazine arcjets, the latter supported by a nuclear reactor. The total mass of the spacecraft is 22,060 kg.

  17. 6. Interior view of control panels on wall of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Interior view of control panels on wall of the signal transfer room on the west side of the Signal Transfer Building (T-28A). - Air Force Plant PJKS, Systems Integration Laboratory, Signal Transfer Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  18. 75 FR 6675 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Human...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-10

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Human Immunodeficiency Virus (HIV... evaluation of applications received in response to ``HIV Prevention Projects for Community Based..., Extramural Programs, National Center for HIV, Hepatitis and Sexually Transmitted Diseases Prevention, 1600...

  19. 75 FR 81555 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Allegheny County's...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    ... Techniques Guidelines for Large Appliance and Metal Furniture; Flat Wood Paneling; Paper, Film, and Foil... appliance and metal furniture; flat wood paneling; and paper, film, and foil surface coating processes. In... Control Techniques Guidelines for Large Appliance and Metal Furniture; Flat Wood Paneling; Paper, Film...

  20. 62. View of amplifiermodulator control system with power distribution panel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. View of amplifier-modulator control system with power distribution panel on left, control power supply in middle, and amplifier modulator on right, second floor in transmitter building no. 102. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  1. 9. Interior view of control panels' (see CO88C6) detail and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Interior view of control panels' (see CO-88-C-6) detail and control junction box on wall of the signal transfer room on the west side of the Signal Transfer Building (T-28A). - Air Force Plant PJKS, Systems Integration Laboratory, Signal Transfer Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  2. Analysis and Design of the NASA Langley Cryogenic Pressure Box

    NASA Technical Reports Server (NTRS)

    Glass, David E.; Stevens, Jonathan C.; Vause, R. Frank; Winn, Peter M.; Maguire, James F.; Driscoll, Glenn C.; Blackburn, Charles L.; Mason, Brian H.

    1999-01-01

    A cryogenic pressure box was designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 72 in. x 60 in. curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20K) with 54 psig maximum pressure on the concave side, and elevated temperatures and atmospheric pressure on the convex surface. The internal surface of the panel is cooled by high pressure helium as that is cooled to -423 F by liquid helium heat exchangers. An array of twelve independently controlled fans circulate the high pressure gaseous helium to provide uniform cooling on the panel surface. The load introduction structure, consisting of four stainless steel load plates and numerous fingers attaching the load plates to the test panel, is designed to introduce loads into the test panel that represent stresses that will he observed in the actual tank structure. The load plates are trace cooled with liquid nitrogen to reduce thermal gradients that may result in bending the load plates, and thus additional stresses in the test panel. The design of the cryogenic systems, load introduction structure, and control system are discussed in this report.

  3. Evaluation of metabolic syndrome prevalence in semi-rural areas of Central Anatolia, Turkey.

    PubMed

    Arikan, Inci; Metintas, Selma; Kalyoncu, Cemalettin; Colak, Omer; Arikan, Ufuk

    2009-08-01

    To assess the prevalence and clustering of components of metabolic syndrome (MetS) in semi-rural areas of Central Anatolia, Turkey. This study was conducted between January and August 2008 on a randomly selected sample of participants from semi-rural settlement areas of the Eskisehir province, Central Anatolia, Turkey. The MetS was diagnosed as the presence of 3, or more risk factors according to the National Cholesterol Education Program-Expert Panel Adult Treatment Panel III (NCEP ATP III) criteria. The MetS prevalence was standardized according to age, and logistic regression was used to determine the risk factors affecting prevalence. The study group composed of 2,766 people (40.4% male, 59.6% female). The corrected MetS prevalence according to age was 27.6%, with values of 19.4% in males, and 33.2% in females. The prevalence increased with increasing age in both genders. Groups engaged in heavy physical exercise, and smoking showed decreased odds of having MetS, while MetS risk was lower in men who consumed proper amounts of red meat, fruits, and vegetables. In the MetS group, central obesity risk was higher for women, whereas hypertriglyceridemia risk was higher for men. In the non-MetS group, hypertension, and central obesity risks were higher for women, whereas hypertriglyceridemia risk was higher for men. It was concluded that MetS is a major problem in the Eskisehir province, and it is imperative that changes in lifestyle be made within this population to reduce the risk factors for the condition.

  4. Development of key performance indicators to evaluate centralized intake for patients with osteoarthritis and rheumatoid arthritis.

    PubMed

    Barber, Claire E; Patel, Jatin N; Woodhouse, Linda; Smith, Christopher; Weiss, Stephen; Homik, Joanne; LeClercq, Sharon; Mosher, Dianne; Christiansen, Tanya; Howden, Jane Squire; Wasylak, Tracy; Greenwood-Lee, James; Emrick, Andrea; Suter, Esther; Kathol, Barb; Khodyakov, Dmitry; Grant, Sean; Campbell-Scherer, Denise; Phillips, Leah; Hendricks, Jennifer; Marshall, Deborah A

    2015-11-14

    Centralized intake is integral to healthcare systems to support timely access to appropriate health services. The aim of this study was to develop key performance indicators (KPIs) to evaluate centralized intake systems for patients with osteoarthritis (OA) and rheumatoid arthritis (RA). Phase 1 involved stakeholder meetings including healthcare providers, managers, researchers and patients to obtain input on candidate KPIs, aligned along six quality dimensions: appropriateness, accessibility, acceptability, efficiency, effectiveness, and safety. Phase 2 involved literature reviews to ensure KPIs were based on best practices and harmonized with existing measures. Phase 3 involved a three-round, online modified Delphi panel to finalize the KPIs. The panel consisted of two rounds of rating and a round of online and in-person discussions. KPIs rated as valid and important (≥7 on a 9-point Likert scale) were included in the final set. Twenty-five KPIs identified and substantiated during Phases 1 and 2 were submitted to 27 panellists including healthcare providers, managers, researchers, and patients in Phase 3. After the in-person meeting, three KPIs were removed and six were suggested. The final set includes 9 OA KPIs, 10 RA KPIs and 9 relating to centralized intake processes for both conditions. All 28 KPIs were rated as valid and important. Arthritis stakeholders have proposed 28 KPIs that should be used in quality improvement efforts when evaluating centralized intake for OA and RA. The KPIs measure five of the six dimensions of quality and are relevant to patients, practitioners and health systems.

  5. Author Correction: Time-dependent memory transformation along the hippocampal anterior-posterior axis.

    PubMed

    Dandolo, Lisa C; Schwabe, Lars

    2018-05-24

    In the originally published version of this Article, the rightmost graph in Fig. 2c was inadvertently replaced with a duplicate of the central panel. This has now been corrected in both the PDF and HTML versions of the Article.

  6. Active control of sound transmission through a rectangular panel using point-force actuators and piezoelectric film sensors.

    PubMed

    Sanada, Akira; Higashiyama, Kouji; Tanaka, Nobuo

    2015-01-01

    This study deals with the active control of sound transmission through a rectangular panel, based on single input, single output feedforward vibration control using point-force actuators and piezoelectric film sensors. It focuses on the phenomenon in which the sound power transmitted through a finite-sized panel drops significantly at some frequencies just below the resonance frequencies of the panel in the low-frequency range as a result of modal coupling cancellation. In a previous study, it was shown that when point-force actuators are located on nodal lines for the frequency at which this phenomenon occurs, a force equivalent to the incident sound wave can act on the panel. In this study, a practical method for sensing volume velocity using a small number of piezoelectric film strips is investigated. It is found that two quadratically shaped piezoelectric film strips, attached at the same nodal lines as those where the actuators were placed, can sense the volume velocity approximately in the low-frequency range. Results of simulations show that combining the proposed actuation method and the sensing method can achieve a practical control effect at low frequencies over a wide frequency range. Finally, experiments are carried out to demonstrate the validity and feasibility of the proposed method.

  7. 76 FR 49771 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Special Interest Project (SIP), Systematic Review of Effective Community-based... Discussed: The meeting will include the initial review, discussion, and evaluation of ``Systematic Review of...

  8. 76 FR 51985 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Special Interest Project (SIP): Systematic Review of Effective Community-based Interventions of Clinical Preventive Services for Older Adults, SIP11-045, initial review. Correction: This...

  9. 144. VIEW OF EAST WALL OF CONTROL ROOM (214), LSB ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    144. VIEW OF EAST WALL OF CONTROL ROOM (214), LSB (BLDG. 751). PNEUMATIC SUPPLY PANEL ON LEFT; NITROGEN AND HELIUM PIPING AT TOP; PURGE PANEL AT BOTTOM OF PHOTOGRAPH. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. 76 FR 367 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Minority HIV...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Minority HIV/AIDS Research... Researchers To Conduct HIV/AIDS Epidemiologic and Prevention Research, Funding Opportunity Announcement (FOA... HIV/AIDS Research Initiative (MARI) to Build Capacity in Black and Hispanic Communities and Among...

  11. 76 FR 31856 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adoption of Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... Flat Wood Paneling Surface Coating Processes AGENCY: Environmental Protection Agency (EPA). ACTION... by EPA's Control Techniques Guidelines (CTG) standards for flat wood paneling surface coating processes. EPA is approving this revision concerning the adoption of the EPA CTG requirements for flat wood...

  12. 76 FR 4578 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ... Wood Paneling Coatings AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule. SUMMARY... (RACT) for sources covered by EPA's Control Techniques Guidelines (CTG) for flat wood paneling coatings. These amendments will reduce emissions of volatile organic compound (VOC) from flat wood coating...

  13. Close up view of switchboard panel operator's station #1; panel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close up view of switchboard panel operator's station #1; panel contains 1200 push-pull button switches which control poer to red, green, and white indicating lights on the model board; white lights indicate that power is off; green lights indicate that equipment (switch breaker or transformer) is off; red lights indicate that equipment is on - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA

  14. Management of Central Venous Access Device-Associated Skin Impairment: An Evidence-Based Algorithm.

    PubMed

    Broadhurst, Daphne; Moureau, Nancy; Ullman, Amanda J

    Patients relying on central venous access devices (CVADs) for treatment are frequently complex. Many have multiple comorbid conditions, including renal impairment, nutritional deficiencies, hematologic disorders, or cancer. These conditions can impair the skin surrounding the CVAD insertion site, resulting in an increased likelihood of skin damage when standard CVAD management practices are employed. Supported by the World Congress of Vascular Access (WoCoVA), developed an evidence- and consensus-based algorithm to improve CVAD-associated skin impairment (CASI) identification and diagnosis, guide clinical decision-making, and improve clinician confidence in managing CASI. A scoping review of relevant literature surrounding CASI management was undertaken March 2014, and results were distributed to an international advisory panel. A CASI algorithm was developed by an international advisory panel of clinicians with expertise in wounds, vascular access, pediatrics, geriatric care, home care, intensive care, infection control and acute care, using a 2-phase, modified Delphi technique. The algorithm focuses on identification and treatment of skin injury, exit site infection, noninfectious exudate, and skin irritation/contact dermatitis. It comprised 3 domains: assessment, skin protection, and patient comfort. External validation of the algorithm was achieved by prospective pre- and posttest design, using clinical scenarios and self-reported clinician confidence (Likert scale), and incorporating algorithm feasibility and face validity endpoints. The CASI algorithm was found to significantly increase participants' confidence in the assessment and management of skin injury (P = .002), skin irritation/contact dermatitis (P = .001), and noninfectious exudate (P < .01). A majority of participants reported the algorithm as easy to understand (24/25; 96%), containing all necessary information (24/25; 96%). Twenty-four of 25 (96%) stated that they would recommend the tool to guide management of CASI.

  15. The fractal characteristic of facial anthropometric data for developing PCA fit test panels for youth born in central China.

    PubMed

    Yang, Lei; Wei, Ran; Shen, Henggen

    2017-01-01

    New principal component analysis (PCA) respirator fit test panels had been developed for current American and Chinese civilian workers based on anthropometric surveys. The PCA panels used the first two principal components (PCs) obtained from a set of 10 facial dimensions. Although the PCA panels for American and Chinese subjects adopted the bivairate framework with two PCs, the number of the PCs retained in the PCA analysis was different between Chinese subjects and Americans. For the Chinese youth group, the third PC should be retained in the PCA analysis for developing new fit test panels. In this article, an additional number label (ANL) is used to explain the third PC in PCA analysis when the first two PCs are used to construct the PCA half-facepiece respirator fit test panel for Chinese group. The three-dimensional box-counting method is proposed to estimate the ANLs by calculating fractal dimensions of the facial anthropometric data of the Chinese youth. The linear regression coefficients of scale-free range R 2 are all over 0.960, which demonstrates that the facial anthropometric data of the Chinese youth has fractal characteristic. The youth subjects born in Henan province has an ANL of 2.002, which is lower than the composite facial anthropometric data of Chinese subjects born in many provinces. Hence, Henan youth subjects have the self-similar facial anthropometric characteristic and should use the particular ANL (2.002) as the important tool along with using the PCA panel. The ANL method proposed in this article not only provides a new methodology in quantifying the characteristics of facial anthropometric dimensions for any ethnic/racial group, but also extends the scope of PCA panel studies to higher dimensions.

  16. An approach to power efficiency determination in the solar energy systems using central composite design and Box-Behnken design

    NASA Astrophysics Data System (ADS)

    Venegas Mendez, Juan

    We are living in an industrialized world that relies on fossil fuels. The ways, in which these fossil fuels have damaged the earth, in special the environment is worth of special attention and corrective actions. In our days, the climate change (global warming) it is becoming the number one topic. These changes are affecting our health, comfort and our way of living. Solar systems have been working among us since several years, but the truth is that most of us really don't understand how they work and more important, how they work in time in different conditions. Solar panels are one of the most promising renewable energy ways to handle electrification requirements off several isolated consumers worldwide. Because of this, it was clear which way to take. The main focus of this research is the study of solar panels; watch their behavior on different conditions to determine on which ones this kind of systems can give us more output power. The variables to deal with are going to be the temperature, the angle of the light and the color temperature of the light, all this occurs on a controlled environment following two different methods to analyze the collected data. As objectives, three different point were stated. To find out if all the variables affect our system, which one is the most significant adobe the other for this particular study and to demonstrate the importance of the color temperature of the light on solar panels electricity production.

  17. Translations on Environmental Quality, Number 148

    DTIC Science & Technology

    1977-10-03

    Article 9. Designs for gas filtering installations must include the proper control and automation facilities as per articles 16 and 17. Article 10...mandatorily equipped with: 1. Locking armature at the gas entrance and exit with manual or remote control flanges for the installation of end-caps in...instruments shall be mounted on the control panel of the gas filtering system or the control panel for the technological process. Article 17. (1) The gas

  18. Evaluation of a Serum Lung Cancer Biomarker Panel.

    PubMed

    Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria

    2018-01-01

    A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.

  19. Evaluation of a Serum Lung Cancer Biomarker Panel

    PubMed Central

    Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria

    2018-01-01

    Background: A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. Methods: The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. Results: The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. Conclusions: This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results. PMID:29371783

  20. Thermal Performance of Orion Active Thermal Control System With Seven-Panel Reduced-Curvature Radiator

    NASA Technical Reports Server (NTRS)

    Wang, Xiao-Yen J.; Yuko, James R.

    2010-01-01

    The active thermal control system (ATCS) of the crew exploration vehicle (Orion) uses radiator panels with fluid loops as the primary system to reject heat from spacecraft. The Lockheed Martin (LM) baseline Orion ATCS uses eight-panel radiator coated with silver Teflon coating (STC) for International Space Station (ISS) missions, and uses seven-panel radiator coated with AZ 93 white paint for lunar missions. As an option to increase the radiator area with minimal impact on other component locations and interfaces, the reduced-curvature (RC) radiator concept was introduced and investigated here for the thermal perspective. Each RC radiator panel has 15 percent more area than each Lockheed Martin (LM) baseline radiator panel. The objective was to determine if the RC seven-panel radiator concept could be used in the ATCS for both ISS and lunar missions. Three radiator configurations the LM baseline, an RC seven-panel radiator with STC, and an RC seven-panel radiator with AZ 93 coating were considered in the ATCS for ISS missions. Two radiator configurations the LM baseline and an RC seven-panel radiator with AZ 93 coating were considered in the ATCS for lunar missions. A Simulink/MATLAB model of the ATCS was used to compute the ATCS performance. Some major hot phases on the thermal timeline were selected because of concern about the large amount of water sublimated for thermal topping. It was concluded that an ATCS with an RC seven-panel radiator could be used for both ISS and lunar missions, but with two different coatings STC for ISS missions and AZ 93 for lunar missions to provide performance similar to or better than that of the LM baseline ATCS.

  1. Closeup view of the Pilot's Seat on the Flight Deck ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Close-up view of the Pilot's Seat on the Flight Deck of the Orbiter Discovery. It appears the Orbiter is in the roll out / launch pad configuration. A protective cover is over the Rotational Hand Controller to protect it during the pilot's ingress. Control panels R1 and R2 are prominent in this view. Panel R1 has switches for control and maintenance of on-board cryogenics for the fuel cells among other functions and panel R2 has switches and controls for the Auxiliary Power Units, ET umbilical doors as well as other operational controls. Note the portable fire extinguisher in the lower right corner of the image. This photograph was taken at Kennedy Space Center. - Space Transportation System, Orbiter Discovery (OV-103), Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  2. A central solar domestic hot water system - Performance and economic analysis

    NASA Astrophysics Data System (ADS)

    Wolf, D.; Tamir, A.; Kudish, A. I.

    1980-02-01

    A solar-assisted central hot water system was retrofitted onto one of the student dormitory complexes. The system consisted of twenty commercial solar collectors, of the pipe and plate type, and central hot water tank connected to two dormitory buildings. The system has two loops: (1) a solar loop, in which the heated water circulates between the collector panels and the central hot water tank, and (2) a consumer loop, where the solar-heated water circulates between the central hot water tank and the dormitory. The solar-heated water circulates through the individual electric hot water tanks which serve as individual hot water storage and booster units, and the mains water is introduced at the bottom of the central tank to replace consumed water. The description of the system, the design and its performance, together with an economic analysis, are presented.

  3. miRNA Profiles in Plasma from Patients with Sleep Disorders Reveal Dysregulation of miRNAs in Narcolepsy and Other Central Hypersomnias

    PubMed Central

    Holm, Anja; Bang-Berthelsen, Claus Heiner; Knudsen, Stine; Kornum, Birgitte R.; Modvig, Signe; Jennum, Poul; Gammeltoft, Steen

    2014-01-01

    Study Objectives: MicroRNAs (miRNAs) have been implicated in the pathogenesis of human diseases including neurological disorders. The aim is to address the involvement of miRNAs in the pathophysiology of central hypersomnias including autoimmune narcolepsy with cataplexy and hypocretin deficiency (type 1 narcolepsy), narcolepsy without cataplexy (type 2 narcolepsy), and idiopathic hypersomnia. Design: We conducted high-throughput analysis of miRNA in plasma from three groups of patients—with type 1 narcolepsy, type 2 narcolepsy, and idiopathic hypersomnia, respectively—in comparison with healthy controls using quantitative real-time polymerase chain reaction (qPCR) panels. Setting: University hospital based sleep clinic and research laboratories. Patients: Twelve patients with type 1 narcolepsy, 12 patients with type 2 narcolepsy, 12 patients with idiopathic hypersomnia, and 12 healthy controls. Measurements and Results: By analyzing miRNA in plasma with qPCR we identified 50, 24, and 6 miRNAs that were different in patients with type 1 narcolepsy, type 2 narcolepsy, and idiopathic hypersomnia, respectively, compared with healthy controls. Twenty miRNA candidates who fulfilled the criteria of at least two-fold difference and p-value < 0.05 were selected to validate the miRNA changes in an independent cohort of patients. Four miRNAs differed significantly between type 1 narcolepsy patients and healthy controls. Levels of miR-30c, let-7f, and miR-26a were higher, whereas the level of miR-130a was lower in type 1 narcolepsy than healthy controls. The miRNA differences were not specific for type 1 narcolepsy, since the levels of the four miRNAs were also altered in patients with type 2 narcolepsy and idiopathic hypersomnia compared with healthy controls. Conclusion: The levels of four miRNAs differed in plasma from patients with type 1 narcolepsy, type 2 narcolepsy and idiopathic hypersomnia suggesting that alterations of miRNAs may be involved in the pathophysiology of central hypersomnias. Citation: Holm A, Bang-Berthelsen CH, Knudsen S, Kornum BR, Modvig S, Jennum P, Gammeltoft S. miRNA profiles in plasma from patients with sleep disorders reveal dysregulation of miRNAs in narcolepsy and other central hypersomnias. SLEEP 2014;37(9):1525-1533. PMID:25142559

  4. 75 FR 1589 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-12

    ... Census Coverage Measurement Recall Bias Panel Study has been added. Two previous notices were published... Reinterview, and Recall Bias Panel Study. OMB Control Number: None. Form Number(s): All data will be collected... different PI enumerator. In addition to the CCM PI Operation, CCM will conduct a Recall Bias Panel Study...

  5. Defense Automation Resources Management Manual

    DTIC Science & Technology

    1988-09-01

    Electronic Command Signals Programmer, Plugboard Programmers Punch, Card Punch, Paper Tape Reader, Character Reader-Generator, Time Cards Reader...Multiplexor-Shift Register Group Multiplier Panel Control, Plugboard Panel, Interconnection, Digital Computer Panel, Meter-Attenuator, Tape Recorder PC Cards...Perforator, Tape Plug-In Unit Potentiometer, Coefficient, Analog Computer Programmer, Plugboard Punch, Paper Tape Racks Reader, Time Code Reader

  6. Experimental and Theoretical Analysis of Sound Absorption Properties of Finely Perforated Wooden Panels.

    PubMed

    Song, Boqi; Peng, Limin; Fu, Feng; Liu, Meihong; Zhang, Houjiang

    2016-11-22

    Perforated wooden panels are typically utilized as a resonant sound absorbing material in indoor noise control. In this paper, the absorption properties of wooden panels perforated with tiny holes of 1-3 mm diameter were studied both experimentally and theoretically. The Maa-MPP (micro perforated panels) model and the Maa-Flex model were applied to predict the absorption regularities of finely perforated wooden panels. A relative impedance comparison and full-factorial experiments were carried out to verify the feasibility of the theoretical models. The results showed that the Maa-Flex model obtained good agreement with measured results. Control experiments and measurements of dynamic mechanical properties were carried out to investigate the influence of the wood characteristics. In this study, absorption properties were enhanced by sound-induced vibration. The relationship between the dynamic mechanical properties and the panel mass-spring vibration absorption was revealed. While the absorption effects of wood porous structure were not found, they were demonstrated theoretically by using acoustic wave propagation in a simplified circular pipe with a suddenly changed cross-section model. This work provides experimental and theoretical guidance for perforation parameter design.

  7. Active control of panel vibrations induced by boundary-layer flow

    NASA Technical Reports Server (NTRS)

    Chow, Pao-Liu

    1991-01-01

    Some problems in active control of panel vibration excited by a boundary layer flow over a flat plate are studied. In the first phase of the study, the optimal control problem of vibrating elastic panel induced by a fluid dynamical loading was studied. For a simply supported rectangular plate, the vibration control problem can be analyzed by a modal analysis. The control objective is to minimize the total cost functional, which is the sum of a vibrational energy and the control cost. By means of the modal expansion, the dynamical equation for the plate and the cost functional are reduced to a system of ordinary differential equations and the cost functions for the modes. For the linear elastic plate, the modes become uncoupled. The control of each modal amplitude reduces to the so-called linear regulator problem in control theory. Such problems can then be solved by the method of adjoint state. The optimality system of equations was solved numerically by a shooting method. The results are summarized.

  8. User's manual: Subsonic/supersonic advanced panel pilot code

    NASA Technical Reports Server (NTRS)

    Moran, J.; Tinoco, E. N.; Johnson, F. T.

    1978-01-01

    Sufficient instructions for running the subsonic/supersonic advanced panel pilot code were developed. This software was developed as a vehicle for numerical experimentation and it should not be construed to represent a finished production program. The pilot code is based on a higher order panel method using linearly varying source and quadratically varying doublet distributions for computing both linearized supersonic and subsonic flow over arbitrary wings and bodies. This user's manual contains complete input and output descriptions. A brief description of the method is given as well as practical instructions for proper configurations modeling. Computed results are also included to demonstrate some of the capabilities of the pilot code. The computer program is written in FORTRAN IV for the SCOPE 3.4.4 operations system of the Ames CDC 7600 computer. The program uses overlay structure and thirteen disk files, and it requires approximately 132000 (Octal) central memory words.

  9. [Methodology for construction of a panel of indicators for monitoring and evaluation of unified health system (SUS) management].

    PubMed

    Tamaki, Edson Mamoru; Tanaka, Oswaldo Yoshimi; Felisberto, Eronildo; Alves, Cinthia Kalyne de Almeida; Drumond Junior, Marcos; Bezerra, Luciana Caroline de Albuquerque; Calvo, Maria Cristina Marino; Miranda, Alcides Silva de

    2012-04-01

    This study sought to develop methodology for the construction of a Panel for the Monitoring and Evaluation of Management of the Unified Health System (SUS). The participative process used in addition to the systematization conducted made it possible to identify an effective strategy for building management tools in partnership with researchers, academic institutions and managers of the SUS. The final systematization of the Panel selected indicators for the management of the SUS in terms of Demand, Inputs, Processes, Outputs and Outcomes in order to provide a simple, versatile and useful tool for evaluation at any level of management and more transparent and easier communication with all stakeholders in decision-making. Taking the management of the SUS as the scope of these processes and practices in all normative aspects enabled dialog between systemic theories and those which consider the centrality of the social actor in the decision-making process.

  10. Preliminary design of the Carrisa Plains solar central receiver power plant. Volume III, Book 3. Appendices, Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mouradian, E. M.

    1983-12-31

    Thermal analyses for the preliminary design phase of the Receiver of the Carrizo Plains Solar Power Plant are presented. The sodium reference operating conditions (T/sub in/ = 610/sup 0/F, T/sub out/ = 1050/sup 0/F) have been considered. Included are: Nominal flux distribution on receiver panal, Energy input to tubes, Axial temperature distribution; sodium and tubes, Sodium flow distribution, Sodium pressure drop, orifice calculations, Temperature distribution in tube cut (R-0), Backface structure, and Nonuniform sodium outlet temperature. Transient conditions and panel front face heat losses are not considered. These are to be addressed in a subsequent design phase. Also to bemore » considered later are the design conditions as variations from the nominal reference (operating) condition. An addendum, designated Appendix C, has been included describing panel heat losses, panel temperature distribution, and tube-manifold joint thermal model.« less

  11. Concealed neuroanatomy in Michelangelo's Separation of Light From Darkness in the Sistine Chapel.

    PubMed

    Suk, Ian; Tamargo, Rafael J

    2010-05-01

    Michelangelo Buonarroti (1475-1564) was a master anatomist as well as an artistic genius. He dissected cadavers numerous times and developed a profound understanding of human anatomy. From 1508 to 1512, Michelangelo painted the ceiling of the Sistine Chapel in Rome. His Sistine Chapel frescoes are considered one of the monumental achievements of Renaissance art. In the winter of 1511, Michelangelo entered the final stages of the Sistine Chapel project and painted 4 frescoes along the longitudinal apex of the vault, which completed a series of 9 central panels depicting scenes from the Book of Genesis. It is reported that Michelangelo concealed an image of the brain in the first of these last 4 panels, namely, the Creation of Adam. Here we present evidence that he concealed another neuronanatomic structure in the final panel of this series, the Separation of Light From Darkness, specifically a ventral view of the brainstem. The Separation of Light From Darkness is an important panel in the Sistine Chapel iconography because it depicts the beginning of Creation and is located directly above the altar. We propose that Michelangelo, a deeply religious man and an accomplished anatomist, intended to enhance the meaning of this iconographically critical panel and possibly document his anatomic accomplishments by concealing this sophisticated neuroanatomic rendering within the image of God.

  12. Utility of genetic testing for the detection of late-onset hearing loss in neonates.

    PubMed

    Lim, B Gail; Clark, Reese H; Kelleher, Amy S; Lin, Zhili; Spitzer, Alan R

    2013-12-01

    The purpose of this study was to demonstrate the utility of molecular testing in the detection of potentially important causes of delayed hearing loss missed by current audiometric screening at birth. We enrolled infants who had received a newborn audiometric hearing screen and a filter paper blood collection for state newborn screening. A central laboratory ran the SoundGene® panel. Of 3,681 infants studied, 35 (0.95%) had a positive SoundGene panel, 16 had mitochondrial mutations, 9 had Pendred mutations, 5 were cytomegalovirus (CMV) DNA positive, 2 had connexin mutations, and 3 had a combination of different mutations. Infants with an abnormal SoundGene panel were at increased risk for hearing loss compared to neonates without mutations. Three (8.6%) of the 35 subjects had persistent hearing loss compared to 5 (0.21%) of 2,398 subjects with no report of mutation (p < .01). Of 3,681 infants studied, 8 (0.22%) had persistent hearing loss: 5 (62.5%) had abnormal newborn audiometric screens, 2 (25%) had an abnormal SoundGene panel (1 was CMV positive, 1 had a mitochondrial mutation), and 1 (12.5%) had no identifiable risk factors. A positive SoundGene panel identifies infants who are not identified by audiometric testing and may be at risk for hearing loss.

  13. Heat Pipe Thermal Conditioning Panel

    NASA Technical Reports Server (NTRS)

    Saaski, E. W.

    1973-01-01

    The technology involved in designing and fabricating a heat pipe thermal conditioning panel to satisfy a broad range of thermal control system requirements on NASA spacecraft is discussed. The design specifications were developed for a 30 by 30 inch heat pipe panel. The fundamental constraint was a maximum of 15 gradient from source to sink at 300 watts input and a flux density of 2 watts per square inch. The results of the performance tests conducted on the panel are analyzed.

  14. General aviation aircraft interior noise problem: Some suggested solutions

    NASA Technical Reports Server (NTRS)

    Roskam, J.; Navaneethan, R.

    1984-01-01

    Laboratory investigation of sound transmission through panels and the use of modern data analysis techniques applied to actual aircraft is used to determine methods to reduce general aviation interior noise. The experimental noise reduction characteristics of stiffened flat and curved panels with damping treatment are discussed. The experimental results of double-wall panels used in the general aviation industry are given. The effects of skin panel material, fiberglass insulation and trim panel material on the noise reduction characteristics of double-wall panels are investigated. With few modifications, the classical sound transmission theory can be used to design the interior noise control treatment of aircraft. Acoustic intensity and analysis procedures are included.

  15. Blackboard system generator (BSG) - An alternative distributed problem-solving paradigm

    NASA Technical Reports Server (NTRS)

    Silverman, Barry G.; Feggos, Kostas; Chang, Joseph Shih

    1989-01-01

    A status review is presented for a generic blackboard-based distributed problem-solving environment in which multiple-agent cooperation can be effected. This environment is organized into a shared information panel, a chairman control panel, and a metaplanning panel. Each panel contains a number of embedded AI techniques that facilitate its operation and that provide heuristics for solving the underlying team-agent decision problem. The status of these panels and heuristics is described along with a number of robustness considerations. The techniques for each of the three panels and for four sets of paradigm-related advances are described, along with selected results from classroom teaching experiments and from three applications.

  16. 19. VIEW OF THE PLATING BATHS AND CONTROL PANELS. GOLD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. VIEW OF THE PLATING BATHS AND CONTROL PANELS. GOLD AND SILVER WERE AMONG THE MATERIALS PLATED ONTO PARTS MADE OF COPPER, STAINLESS STEEL AND STEEL. (11/15/89) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO

  17. 7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. CONSTRUCTION PROGRESS VIEW (INTERIOR) OF CONTROL ROOM PANEL INSIDE BUNKER. SHOWS OPENING TO CABLE CHASE, FOUR PULLEY DEVICES, POWER OUTLET, CONDUIT, AND EAST END WALL OF BUNKER. INEL PHOTO NUMBER 65-5441, TAKEN OCTOBER 20, 1965. - Idaho National Engineering Laboratory, Advanced Reentry Vehicle Fusing System, Scoville, Butte County, ID

  18. Industry/Government Teleconference on Pollution Control. Proceedings National Telecast and Local Panel Sessions.

    ERIC Educational Resources Information Center

    National Association of Manufacturers, New York, NY.

    Proceedings of the closed-circuit Teleconference on Pollution Control conducted by the National Association of Manufacturers on May 26, 1971 are supplied in this compendium. Edited transcripts are provided for the national programs and local panel sessions. Seeking to bring business and government together for cooperative problem solving, the…

  19. Structural Dynamics and Control Interaction of Flexible Structures

    NASA Technical Reports Server (NTRS)

    Ryan, Robert S. (Editor); Scofield, Harold N. (Editor)

    1987-01-01

    A Workshop was held to promote technical exchange between the structural dynamic and control disciplines, foster joint technology, and provide a forum for discussing and focusing critical issues in the separate and combined areas. The workshop was closed by a panel meeting. Panel members' viewpoints and their responses to questions are included.

  20. INTERIOR VIEW OF TRANSFORMER ROOM FOR FURNACE NO. 2 LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR VIEW OF TRANSFORMER ROOM FOR FURNACE NO. 2 LOOKING SOUTHEAST, SHOWING BACK OF CONTROL PANEL AND TRANSFORMER (GE, 3000 KUA water cooled, 60 cycles, U.S. patent 1900585. Transformer dates from 1937, control panel GE resistors) - Braeburn Alloy Steel, Braeburn Road at Allegheny River, Lower Burrell, Westmoreland County, PA

  1. 46. BUILDING NO. 519, ETHER AND ALCOHOL RECOVERY HOUSE, INTERIOR, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. BUILDING NO. 519, ETHER AND ALCOHOL RECOVERY HOUSE, INTERIOR, CONTROL PANEL LEVEL (2ND DECK) OF ETHER AND ALCOHOL STILL BUILDING, LOOKING NORTH, SHOWING TWO ALCOHOL DISTILLATION TOWERS BEHIND 'MIXED SOLVENT UNIT' CONTROL PANEL. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ

  2. 75 FR 78999 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-17

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal Vitamin D Status and..., discussion, and evaluation of ``Maternal Vitamin D Status and Preterm Birth, DP11-002, initial review.'' Contact Person for More Information: Donald Blackman, PhD, Scientific Review Officer, CDC, National Center...

  3. 75 FR 28261 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Improved...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-20

    ... in response to ``Improved Diagnostics Lyme Borreliosis,'' FOA CK10-005. FOR MORE INFORMATION CONTACT..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Improved Diagnostics for Lyme Borreliosis, Funding Opportunity Announcement (FOA) CK10-005; Initial Review In accordance with Section 10(a...

  4. Astronauts Gibson and Pogue at Apollo Telescope Mount display/control panel

    NASA Image and Video Library

    1973-09-10

    S73-32837 (10 Sept. 1973) --- Scientist-astronaut Edward G. Gibson, seated, and astronaut William R. Pogue discuss a mission procedure at the Apollo Telescope Mount (ATM) display and control panel mock-up in the one-G trainer for the Multiple Docking Adapter (MDA) at Johnson Space Center. Photo credit: NASA

  5. 18. NORTH SIDE OF CONTROL ROOM SHOWING MAIN ELECTRIC PANEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. NORTH SIDE OF CONTROL ROOM SHOWING MAIN ELECTRIC PANEL ON LEFT, SIGNAL SWITCH BOX IN CENTER, AND SIGNAL RELAYS ON RIGHT. RESISTOR BANK BEHIND ON RIGHT. BRIDGE TENDER'S DESK BEHIND ON SOUTH SIDE. (Fred Small) - Burlington Northern Railroad Bridge, Spanning Willamette River at River Mile 6.9, Portland, Multnomah County, OR

  6. PROCESS WATER BUILDING, TRA605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROCESS WATER BUILDING, TRA-605. CONTROL PANEL SUPPLIES STATUS INDICATORS. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4219. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  7. Control device for automatic orientation of a solar panel based on a microcontroller (PIC16f628a)

    NASA Astrophysics Data System (ADS)

    Rezoug, M. R.; Krama, A.

    2016-07-01

    This work proposes a control device for autonomous solar tracker based on one axis, It consists of two main parts; the control part which is based on "the PIC16f628a"; it has the role of controlling, measuring and plotting responses. The second part is a mechanical device, which has the role of making the solar panel follows the day-night change of the sun throughout the year. Both parties are established to improve energy generation of the photovoltaic panels. In this paper, we will explain the main operating principles of our system. Also, we will provide experimental results which demonstrate the good performance and the efficiency of this system. This innovation is different from what has been proposed in previous studies. The important points of this system are maximum output energy and minimum energy consumption of solar tracker, its cost is relatively low with simplicity in implementation. The average power increase produced by using the tracking system for a particular day, is over 30 % compared with the static panel.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Michael; Spindler, Jeff

    For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecturemore » has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.« less

  9. Environmental Panels as a Proxy for Nursing Facility Patients With Methicillin-Resistant Staphylococcus Aure and Vancomycin-Resistant Enterococcus Colonization.

    PubMed

    Cassone, Marco; Mantey, Julia; Perri, Mary Beth; Gibson, Kristen; Lansing, Bonnie; McNamara, Sara; Patel, Payal K; Cheng, Vincent C C; Walters, Maroya S; Stone, Nimalie D; Zervos, Marcus J; Mody, Lona

    2018-05-02

    Most nursing facilities (NFs) lack methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant Enterococcus (VRE) surveillance programs due to limited resources and high costs. We investigated the utility of environmental screening of high-touch surfaces in patient rooms as a way to circumvent these challenges. We compared MRSA and VRE culture data from high-touch surfaces in patients' rooms (14450 samples from 6 NFs) and ranked each site's performance in predicting patient colonization (7413 samples). The best-performing sites were included in a MRSA- and a VRE-specific panel that functioned as a proxy for patient colonization. Molecular typing was performed to confirm available concordant patient-environment pairs. We identified and validated a MRSA panel that consisted of the bed controls, nurse call button, bed rail, and TV remote control. The VRE panel included the toilet seat, bed controls, bed rail, TV remote control, and top of the side table. Panel colonization data tracked patient colonization. Negative predictive values were 89%-92% for MRSA and 82%-84% for VRE. Molecular typing confirmed a strong clonal type relationship in available concordant patient-environment pairs (98% for MRSA, 91% for VRE), pointing to common epidemiological patterns for environmental and patient isolates. Environmental panels used as a proxy for patient colonization and incorporated into facility surveillance protocols can guide decolonization strategies, improve awareness of MRSA and VRE burden, and inform efforts to reduce transmission. Targeted environmental screening may be a viable surveillance strategy for MRSA and VRE detection in NFs.

  10. The Outdoor Air Pollution and Brain Health Workshop

    PubMed Central

    Block, Michelle L.; Elder, Alison; Auten, Rick L.; Bilbo, Staci D.; Chen, Honglei; Chen, Jiu-Chiuan; Cory-Slechta, Deborah A.; Costa, Daniel; Diaz-Sanchez, David; Dorman, David C.; Gold, Diane; Gray, Kimberly; Jeng, Hueiwang Anna; Kaufman, Joel D.; Kleinman, Michael T.; Kirshner, Annette; Lawler, Cindy; Miller, David S.; Nadadur, Sri; Ritz, Beate; Semmens, Erin O.; Tonelli, Leonardo H.; Veronesi, Bellina; Wright, Robert O.; Wright, Rosalind

    2013-01-01

    Accumulating evidence suggests that outdoor air pollution may have a significant impact on central nervous system (CNS) health and disease. To address this issue, the National Institute of Environmental Health Sciences/National Institute of Health convened a panel of research scientists that was assigned the task of identifying research gaps and priority goals essential for advancing this growing field and addressing an emerging human health concern. Here, we review recent findings that have established the effects of inhaled air pollutants in the brain, explore the potential mechanisms driving these phenomena, and discuss the recommended research priorities/approaches that were identified by the panel. PMID:22981845

  11. KSC-98pc147

    NASA Image and Video Library

    1998-01-09

    STS-90 Payload Specialist James Pawelczyk, Ph.D., holds up a panel as one of the items used during the Crew Equipment Interface Test (CEIT) in Kennedy Space Center's (KSC's) Operations and Checkout Building, where the Neurolab payload is undergoing processing. The CEIT gives astronauts an opportunity to get a hands-on look at the payloads with which they will be working on-orbit. STS-90 is scheduled to launch aboard the Shuttle Columbia from KSC on April 2. Investigations during the Neurolab mission will focus on the effects of microgravity on the nervous system. Specifically, experiments will study the adaptation of the vestibular system, the central nervous system, and the pathways that control the ability to sense location in the absence of gravity, as well as the effect of microgravity on a developing nervous system

  12. Performance of active feedforward control systems in non-ideal, synthesized diffuse sound fields.

    PubMed

    Misol, Malte; Bloch, Christian; Monner, Hans Peter; Sinapius, Michael

    2014-04-01

    The acoustic performance of passive or active panel structures is usually tested in sound transmission loss facilities. A reverberant sending room, equipped with one or a number of independent sound sources, is used to generate a diffuse sound field excitation which acts as a disturbance source on the structure under investigation. The spatial correlation and coherence of such a synthesized non-ideal diffuse-sound-field excitation, however, might deviate significantly from the ideal case. This has consequences for the operation of an active feedforward control system which heavily relies on the acquisition of coherent disturbance source information. This work, therefore, evaluates the spatial correlation and coherence of ideal and non-ideal diffuse sound fields and considers the implications on the performance of a feedforward control system. The system under consideration is an aircraft-typical double panel system, equipped with an active sidewall panel (lining), which is realized in a transmission loss facility. Experimental results for different numbers of sound sources in the reverberation room are compared to simulation results of a comparable generic double panel system excited by an ideal diffuse sound field. It is shown that the number of statistically independent noise sources acting on the primary structure of the double panel system depends not only on the type of diffuse sound field but also on the sample lengths of the processed signals. The experimental results show that the number of reference sensors required for a defined control performance exhibits an inverse relationship to control filter length.

  13. Ottawa Panel Evidence-Based Clinical Practice Guidelines for Structured Physical Activity in the Management of Juvenile Idiopathic Arthritis.

    PubMed

    Cavallo, Sabrina; Brosseau, Lucie; Toupin-April, Karine; Wells, George A; Smith, Christine A; Pugh, Arlanna G; Stinson, Jennifer; Thomas, Roanne; Ahmed, Sara; Duffy, Ciarán M; Rahman, Prinon; Àlvarez-Gallardo, Inmaculada C; Loew, Laurianne; De Angelis, Gino; Feldman, Debbie Ehrmann; Majnemer, Annette; Gagnon, Isabelle J; Maltais, Désirée; Mathieu, Marie-Ève; Kenny, Glen P; Tupper, Susan; Whitney-Mahoney, Kristi; Bigford, Sarah

    2017-05-01

    To create guidelines focused on the use of structured physical activity (PA) in the management of juvenile idiopathic arthritis (JIA). A systematic literature search was conducted using the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE (Ovid), EMBASE (Ovid), and Physiotherapy Evidence Database for all studies related to PA programs for JIA from January 1966 until December 2014, and was updated in May 2015. Study selection was completed independently by 2 reviewers. Studies were included if they involved individuals aged ≤21 years diagnosed with JIA who were taking part in therapeutic exercise or other PA interventions for which effects of various disease-related outcomes were compared with a control group (eg, no PA program or activity of lower intensity). Two reviewers independently extracted information on interventions, comparators, outcomes, time period, and study design. The statistical analysis was reported using the Cochrane Collaboration methods. The quality of the included studies was assessed according to the Physiotherapy Evidence Database Scale. Five randomized controlled trials (RCTs) fit the selection criteria; of these, 4 were high-quality RCTs. The following recommendations were developed: (1) Pilates for improving quality of life, pain, functional ability, and range of motion (ROM) (grade A); (2) home exercise program for improving quality of life and functional ability (grade A); (3) aquatic aerobic fitness for decreasing the number of active joints (grade A); and (4) and cardio-karate aerobic exercise for improving ROM and number of active joints (grade C+). The Ottawa Panel recommends the following structured exercises and physical activities for the management of JIA: Pilates, cardio-karate, home and aquatic exercises. Pilates showed improvement in a higher number of outcomes. Copyright © 2017. Published by Elsevier Inc.

  14. A Multiplexed Serum Biomarker Immunoassay Panel Discriminates Clinical Lung Cancer Patients from High-Risk Individuals Found to be Cancer-Free by CT Screening

    PubMed Central

    Bigbee, William L.; Gopalakrishnan, Vanathi; Weissfeld, Joel L.; Wilson, David O.; Dacic, Sanja; Lokshin, Anna E.; Siegfried, Jill M.

    2012-01-01

    Introduction Clinical decision-making in the setting of CT screening could benefit from accessible biomarkers that help predict the level of lung cancer risk in high-risk individuals with indeterminate pulmonary nodules. Methods To identify candidate serum biomarkers, we measured 70 cancer-related proteins by Luminex xMAP® multiplexed immunoassays in a training set of sera from 56 patients with biopsy-proven primary non small cell lung cancer and 56 age-, sex- and smoking-matched CT-screened controls. Results We identified a panel of 10 serum biomarkers – prolactin, transthyretin, thrombospondin-1, E-selectin, C-C motif chemokine 5, macrophage migration inhibitory factor, plasminogen activator inhibitor, receptor tyrosine-protein kinase, Cyfra 21.1, and serum amyloid A – that distinguished lung cancer from controls with an estimated balanced accuracy (average of sensitivity and specificity) of 76.0%±3.8% from 20-fold internal cross-validation. We then iteratively evaluated this model in independent test and verification case/control studies confirming the initial classification performance of the panel. The classification performance of the 10-biomarker panel was also analytically validated using ELISAs in a second independent case/control population further validating the robustness of the panel. Conclusions The performance of this 10-biomarker panel based model was 77.1% sensitivity/76.2% specificity in cross-validation in the expanded training set, 73.3% sensitivity/93.3% specificity (balanced accuracy 83.3%) in the blinded verification set with the best discriminative performance in Stage I/II cases: 85% sensitivity (balanced accuracy 89.2%). Importantly, the rate of misclassification of CT-screened controls was not different in most control subgroups with or without airflow obstruction or emphysema or pulmonary nodules. These biomarkers have potential to aid in the early detection of lung cancer and more accurate interpretation of indeterminate pulmonary nodules detected by screening CT. PMID:22425918

  15. Aircraft panel with sensorless active sound power reduction capabilities through virtual mechanical impedances

    NASA Astrophysics Data System (ADS)

    Boulandet, R.; Michau, M.; Micheau, P.; Berry, A.

    2016-01-01

    This paper deals with an active structural acoustic control approach to reduce the transmission of tonal noise in aircraft cabins. The focus is on the practical implementation of the virtual mechanical impedances method by using sensoriactuators instead of conventional control units composed of separate sensors and actuators. The experimental setup includes two sensoriactuators developed from the electrodynamic inertial exciter and distributed over an aircraft trim panel which is subject to a time-harmonic diffuse sound field. The target mechanical impedances are first defined by solving a linear optimization problem from sound power measurements before being applied to the test panel using a complex envelope controller. Measured data are compared to results obtained with sensor-actuator pairs consisting of an accelerometer and an inertial exciter, particularly as regards sound power reduction. It is shown that the two types of control unit provide similar performance, and that here virtual impedance control stands apart from conventional active damping. In particular, it is clear from this study that extra vibrational energy must be provided by the actuators for optimal sound power reduction, mainly due to the high structural damping in the aircraft trim panel. Concluding remarks on the benefits of using these electrodynamic sensoriactuators to control tonal disturbances are also provided.

  16. What You Can--and Can't--Do with Three-Wave Panel Data

    ERIC Educational Resources Information Center

    Vaisey, Stephen; Miles, Andrew

    2017-01-01

    The recent change in the general social survey (GSS) to a rotating panel design is a landmark development for social scientists. Sociological methodologists have argued that fixed-effects (FE) models are generally the best starting point for analyzing panel data because they allow analysts to control for unobserved time-constant heterogeneity. We…

  17. 75 FR 35764 - Proposed Information Collection; Comment Request; Survey of Income and Program Participation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-23

    ... survey designed as a continuous series of national panels. The SIPP is molded around a central ``core... DEPARTMENT OF COMMERCE U.S. Census Bureau Proposed Information Collection; Comment Request; Survey... supplemented with questions designed to address specific needs. Examples of these types of questions include...

  18. Panel discussion review: Session two - Interpretation of Observed Associations between Multiple Ambient Air Pollutants and Health Effects in Epidemiologic Analysis

    EPA Science Inventory

    Air pollution epidemiologic research has often utilized ambient air concentrations measured from centrally located monitors as a surrogate measure of exposure to these pollutants. Associations between these ambient concentrations and health outcomes such as lung function, hospita...

  19. The PLATO IV Communications System.

    ERIC Educational Resources Information Center

    Sherwood, Bruce Arne; Stifle, Jack

    The PLATO IV computer-based educational system contains its own communications hardware and software for operating plasma-panel graphics terminals. Key echoing is performed by the central processing unit: every key pressed at a terminal passes through the entire system before anything appears on the terminal's screen. Each terminal is guaranteed…

  20. 6. VIEW NORTH, INTERIOR OF STORE Note ceiling stripped for ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. VIEW NORTH, INTERIOR OF STORE Note ceiling stripped for addition of supports, but tongue and groove wall panelling and shelving showing. To the left the stairway enclosure was added with door for front entry to the upper apartments. - 510 Central Avenue (Commercial Building), Ridgely, Caroline County, MD

  1. 75 FR 70971 - Special Medical Advisory Group; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-19

    ... DEPARTMENT OF VETERANS AFFAIRS Special Medical Advisory Group; Notice of Meeting The Department of... Special Medical Advisory Group will meet on December 1, 2010, in Room 830 at VA Central Office, 810... on the Blue Ribbon Panel on VA-Medical School Affiliations Report. Any member of the public wishing...

  2. Piezoceramic Actuator Placement for Acoustic Control of Panels

    NASA Technical Reports Server (NTRS)

    Bevan, Jeffrey S.; Turner, Travis L. (Technical Monitor)

    2001-01-01

    Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibits enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.

  3. Piezoceramic Actuator Placement for Acoustic Control of Panels

    NASA Technical Reports Server (NTRS)

    Bevan, Jeffrey S.

    2000-01-01

    Optimum placement of multiple traditional piezoceramic actuators is determined for active structural acoustic control of flat panels. The structural acoustic response is determined using acoustic radiation filters and structural surface vibration characteristics. Linear Quadratic Regulator (LQR) control is utilized to determine the optimum state feedback gain for active structural acoustic control. The optimum actuator location is determined by minimizing the structural acoustic radiated noise using a modified genetic algorithm. Experimental tests are conducted and compared to analytical results. Anisotropic piezoceramic actuators exhibit enhanced performance when compared to traditional isotropic piezoceramic actuators. As a result of the inherent isotropy, these advanced actuators develop strain along the principal material axis. The orientation of anisotropic actuators is investigated on the effect of structural vibration and acoustic control of curved and flat panels. A fully coupled shallow shell finite element formulation is developed to include anisotropic piezoceramic actuators for shell structures.

  4. Active control of sound transmission through a double panel partition

    NASA Astrophysics Data System (ADS)

    Sas, P.; Bao, C.; Augusztinovicz, F.; Desmet, W.

    1995-03-01

    The feasibility of improving the insertion loss of lightweight double panel partitions by using small loudspeakers as active noise control sources inside the air gap between both panels of the partition is investigated analytically, numerically and experimentally in this paper. A theoretical analysis of the mechanisms of the fluid-structure interaction of double panel structures is presented in order to gain insight into the physical phenomena underlying the behaviour of a coupled vibro-acoustic system controlled by active methods. The analysis, based on modal coupling theory, enables one to derive some qualitative predictions concerning the potentials and limitations of the proposed approach. The theoretical analysis is valid only for geometrically simple structures. For more complex geometries, numerical simulations are required. Therefore the potential use of active noise control inside double panel structures has been analyzed by using coupled finite element and boundary element methods. To verify the conclusions drawn from the theoretical analysis and the numerical calculation and, above all, to demonstrate the potential of the proposed approach, experiments have been conducted with a laboratory set-up. The performance of the proposed approach was evaluated in terms of relative insertion loss measurements. It is shown that a considerable improvement of the insertion loss has been achieved around the lightly damped resonances of the system for the frequency range investigated (60-220 Hz).

  5. Technical advances of interventional fluoroscopy and flat panel image receptor.

    PubMed

    Lin, Pei-Jan Paul

    2008-11-01

    In the past decade, various radiation reducing devices and control circuits have been implemented on fluoroscopic imaging equipment. Because of the potential for lengthy fluoroscopic procedures in interventional cardiovascular angiography, these devices and control circuits have been developed for the cardiac catheterization laboratories and interventional angiography suites. Additionally, fluoroscopic systems equipped with image intensifiers have benefited from technological advances in x-ray tube, x-ray generator, and spectral shaping filter technologies. The high heat capacity x-ray tube, the medium frequency inverter generator with high performance switching capability, and the patient dose reduction spectral shaping filter had already been implemented on the image intensified fluoroscopy systems. These three underlying technologies together with the automatic dose rate and image quality (ADRIQ) control logic allow patients undergoing cardiovascular angiography procedures to benefit from "lower patient dose" with "high image quality." While photoconductor (or phosphor plate) x-ray detectors and signal capture thin film transistor (TFT) and charge coupled device (CCD) arrays are analog in nature, the advent of the flat panel image receptor allowed for fluoroscopy procedures to become more streamlined. With the analog-to-digital converter built into the data lines, the flat panel image receptor appears to become a digital device. While the transition from image intensified fluoroscopy systems to flat panel image receptor fluoroscopy systems is part of the on-going "digitization of imaging," the value of a flat panel image receptor may have to be evaluated with respect to patient dose, image quality, and clinical application capabilities. The advantage of flat panel image receptors has yet to be fully explored. For instance, the flat panel image receptor has its disadvantages as compared to the image intensifiers; the cost of the equipment is probably the most obvious. On the other hand, due to its wide dynamic range and linearity, lowering of patient dose beyond current practice could be achieved through the calibration process of the flat panel input dose rate being set to, for example, one half or less of current values. In this article various radiation saving devices and control circuits are briefly described. This includes various types of fluoroscopic systems designed to strive for reduction of patient exposure with the application of spectral shaping filters. The main thrust is to understand the ADRIQ control logic, through equipment testing, as it relates to clinical applications, and to show how this ADRIQ control logic "ties" those three technological advancements together to provide low radiation dose to the patient with high quality fluoroscopic images. Finally, rotational angiography with computed tomography (CT) and three dimensional (3-D) images utilizing flat panel technology will be reviewed as they pertain to diagnostic imaging in cardiovascular disease.

  6. 4. Main Control Switchboard (south end rear), view to the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Main Control Switchboard (south end rear), view to the north, with item 2 (the load frequency control panel) visible in right foreground, through item 7 (generator Unit 4 control panel) obliquely visible on left side of the photograph. Part of item 1 (the synchronization monitor) is visible behind the phone on right side of photograph. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  7. 7. Interior view of control panels' (see CO88C6) detail on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Interior view of control panels' (see CO-88-C-6) detail on wall of the signal transfer room on the west side of the Signal Transfer Building (T-28A). - Air Force Plant PJKS, Systems Integration Laboratory, Signal Transfer Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  8. 8. Interior view of control panels' (see CO88C6) detail on ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Interior view of control panels' (see CO-88-C-6) detail on wall of the signal transfer room on the west side of the Signal Transfer Building (T-28A). - Air Force Plant PJKS, Systems Integration Laboratory, Signal Transfer Building, Waterton Canyon Road & Colorado Highway 121, Lakewood, Jefferson County, CO

  9. Application of Guided Inquiry System Technique (GIST) to Controlled Ecological Life Support Systems (CELSS)

    NASA Technical Reports Server (NTRS)

    Aroeste, H.

    1982-01-01

    Guided Inquiry System Technique, a global approach to problem solving, was applied to the subject of Controlled Ecological Life Support Systems (CELSS). Nutrition, food processing, and the use of higher plants in a CELSS were considered by a panel of experts. Specific ideas and recommendations gleaned from discussions with panel members are presented.

  10. Reliability of stiffened structural panels: Two examples

    NASA Technical Reports Server (NTRS)

    Stroud, W. Jefferson; Davis, D. Dale, Jr.; Maring, Lise D.; Krishnamurthy, Thiagaraja; Elishakoff, Isaac

    1992-01-01

    The reliability of two graphite-epoxy stiffened panels that contain uncertainties is examined. For one panel, the effect of an overall bow-type initial imperfection is studied. The size of the bow is assumed to be a random variable. The failure mode is buckling. The benefits of quality control are explored by using truncated distributions. For the other panel, the effect of uncertainties in a strain-based failure criterion is studied. The allowable strains are assumed to be random variables. A geometrically nonlinear analysis is used to calculate a detailed strain distribution near an elliptical access hole in a wing panel that was tested to failure. Calculated strains are used to predict failure. Results are compared with the experimental failure load of the panel.

  11. 28. A typical main control panel in a 105 reactor ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. A typical main control panel in a 105 reactor building, in this case 105-F in February 1945. A single operator sat at the controls to regulate the pile's rate of reaction and monitor it for safety. The galvanometer screens (the two horizontal bars just below the nine round gauges that showed the positions of the control rods) showed the pile's current power setting. With that information, the operator could set the control rod positions to increase, decrease, or maintain the power. D-8310 - B Reactor, Richland, Benton County, WA

  12. Biomarker responses to weaning stress in beef calves.

    PubMed

    O'Loughlin, Aran; McGee, Mark; Doyle, Sean; Earley, Bernadette

    2014-10-01

    The study objective was to investigate the physiological effects of weaning on beef calves and identify a panel of blood-based welfare biomarkers. On the day (d) of weaning (d 0), 16 spring-born, single-suckled, beef bull calves that previously grazed with their dams at pasture, were assigned to one of two treatments: (1) control (n = 8), calves were loose-housed with their dam, (2) weaned (n = 8), calves were abruptly separated from their dam and loose-housed. Jugular blood was collected on d -4, 0, 1, 2, 3, 7, and 14 relative to weaning (d 0) and assayed for inflammatory and steroid variables. Total leukocyte counts were measured in whole blood. It is concluded that neutrophil number is a robust biomarker of stress and that plasma CXCL8 is a sensitive indicator of stress in weaned and control calves. In future studies, these two biomarkers should be central to the characterisation of stress responses. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Collocation and Pattern Recognition Effects on System Failure Remediation

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.; Press, Hayes N.

    2007-01-01

    Previous research found that operators prefer to have status, alerts, and controls located on the same screen. Unfortunately, that research was done with displays that were not designed specifically for collocation. In this experiment, twelve subjects evaluated two displays specifically designed for collocating system information against a baseline that consisted of dial status displays, a separate alert area, and a controls panel. These displays differed in the amount of collocation, pattern matching, and parameter movement compared to display size. During the data runs, subjects kept a randomly moving target centered on a display using a left-handed joystick and they scanned system displays to find a problem in order to correct it using the provided checklist. Results indicate that large parameter movement aided detection and then pattern recognition is needed for diagnosis but the collocated displays centralized all the information subjects needed, which reduced workload. Therefore, the collocated display with large parameter movement may be an acceptable display after familiarization because of the possible pattern recognition developed with training and its use.

  14. 10. View (looking west) of the ground floor in the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. View (looking west) of the ground floor in the south segment of the building. The door opening is on the Central Avenue sidewalk. The ground floor had two noteworthy pressed-steel ceilings, an elaborate one in the larger west room and a plain one in the smaller 'back room.' Most of the elaborate ceiling panels were removed when a suspended ceiling (here removed) was installed. The plain ceiling is still in-tact above the suspended ceiling. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  15. Experimental and Theoretical Analysis of Sound Absorption Properties of Finely Perforated Wooden Panels

    PubMed Central

    Song, Boqi; Peng, Limin; Fu, Feng; Liu, Meihong; Zhang, Houjiang

    2016-01-01

    Perforated wooden panels are typically utilized as a resonant sound absorbing material in indoor noise control. In this paper, the absorption properties of wooden panels perforated with tiny holes of 1–3 mm diameter were studied both experimentally and theoretically. The Maa-MPP (micro perforated panels) model and the Maa-Flex model were applied to predict the absorption regularities of finely perforated wooden panels. A relative impedance comparison and full-factorial experiments were carried out to verify the feasibility of the theoretical models. The results showed that the Maa-Flex model obtained good agreement with measured results. Control experiments and measurements of dynamic mechanical properties were carried out to investigate the influence of the wood characteristics. In this study, absorption properties were enhanced by sound-induced vibration. The relationship between the dynamic mechanical properties and the panel mass-spring vibration absorption was revealed. While the absorption effects of wood porous structure were not found, they were demonstrated theoretically by using acoustic wave propagation in a simplified circular pipe with a suddenly changed cross-section model. This work provides experimental and theoretical guidance for perforation parameter design. PMID:28774063

  16. NASA Aircraft Controls Research, 1983

    NASA Technical Reports Server (NTRS)

    Beasley, G. P. (Compiler)

    1984-01-01

    The workshop consisted of 24 technical presentations on various aspects of aircraft controls, ranging from the theoretical development of control laws to the evaluation of new controls technology in flight test vehicles. A special report on the status of foreign aircraft technology and a panel session with seven representatives from organizations which use aircraft controls technology were also included. The controls research needs and opportunities for the future as well as the role envisioned for NASA in that research were addressed. Input from the panel and response to the workshop presentations will be used by NASA in developing future programs.

  17. PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timothy Garfield; William D. Richins; Thomas K. Larson

    The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel barmore » reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.« less

  18. Retrospective Evaluation of Infants Aged 1-60 Days With Residual CSF Tested Using the FilmArray® Meningitis/Encephalitis (ME) Panel.

    PubMed

    Blaschke, Anne J; Holmberg, Kristen M; Daly, Judy A; Leber, Amy L; Dien Bard, Jennifer; Korgenski, Ernest K; Bourzac, Kevin M; Kanack, Kristen J

    2018-04-18

    In pediatric practice it is common for infants under 2 months of age to undergo evaluation for sepsis when they are ill, often including lumbar puncture (LP) to assess for central nervous system (CNS) infection. The FilmArray® Meningitis/Encephalitis (ME) Panel is a newly approved test for rapid identification of CNS pathogens. Our objective was to study the epidemiology of CNS infection in young infants and the potential impact of rapid multiplex PCR on their care.A performance evaluation of the FilmArray ME Panel was conducted from 2/2014-9/2014 at 11 sites. FilmArray ME Panel results were compared to reference standards but not shared with providers. In our study, medical records for infants (aged 1-60 days) enrolled at 3 sites were reviewed for clinical, laboratory and outcome data.145 infants were reviewed. Median age was 25 days. Most were hospitalized [134/145 (92%)], received antibiotics [123/145 (85%)] and almost half [71/145 (49%)] received acyclovir. One infant had a bacterial pathogen, likely false-positive, identified by the FilmArray ME Panel. Thirty-six infants (25%) had a viral pathogen detected, including 21 enteroviruses. All infants with enteroviral meningitis detected by the FilmArray ME Panel and conventional PCR were hospitalized, but 20% were discharged in less than 24 hours when conventional PCR results became available.The FilmArray ME Panel may play a role in the evaluation of young infants for CNS infection. Results may be used to guide management, possibly resulting in decreased length of stay and antimicrobial exposure for infants with low-risk viral infection detected. Copyright © 2018 Blaschke et al.

  19. Design, construction, and testing of the direct absorption receiver panel research experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chavez, J.M.; Rush, E.E.; Matthews, C.W.

    1990-01-01

    A panel research experiment (PRE) was designed, built, and tested as a scaled-down model of a direct absorption receiver (DAR). The PRE is a 3-MW{sub t}DAR experiment that will allow flow testing with molten nitrate salt and provide a test bed for DAR testing with actual solar heating. In a solar central receiver system DAR, the heat absorbing fluid (a blackened molten nitrate salt) flows in a thin film down a vertical panel (rather than through tubes as in conventional receiver designs) and absorbs the concentrated solar flux directly. The ability of the flowing salt film to absorb flux directly.more » The ability of the flowing salt film to absorb the incident solar flux depends on the panel design, hydraulic and thermal fluid flow characteristics, and fluid blackener properties. Testing of the PRE is being conducted to demonstrate the engineering feasibility of the DAR concept. The DAR concept is being investigated because it offers numerous potential performance and economic advantages for production of electricity when compared to other solar receiver designs. The PRE utilized a 1-m wide by 6-m long absorber panel. The salt flow tests are being used to investigate component performance, panel deformations, and fluid stability. Salt flow testing has demonstrated that all the DAR components work as designed and that there are fluid stability issues that need to be addressed. Future solar testing will include steady-state and transient experiments, thermal loss measurements, responses to severe flux and temperature gradients and determination of peak flux capability, and optimized operation. In this paper, we describe the design, construction, and some preliminary flow test results of the Panel Research Experiment. 11 refs., 8 figs., 2 tabs.« less

  20. Dynamics of vacuum-sealed, double-leaf partitions

    NASA Astrophysics Data System (ADS)

    Kavanaugh, Joshua Stephen

    The goal of this research is to investigate the feasibility and potential effectiveness of using vacuum-sealed, double-leaf partitions for applications in noise control. Substantial work has been done previously on double-leaf partitions where the acoustics of the inner chamber and mechanical vibrations of structural supports are passively and actively controlled. The work presented here is unique in that the proposed system aims to eliminate the need for active acoustic control of transmitted acoustic energy by removing all the air between the two panels of the double partition. Therefore, the only remaining energy paths would be along the boundary and at the points where there are intermediate structural supports connecting the two panels. The eventual goal of the research is to develop a high-loss double-leaf partition that simplifies active control by removing the need for control of the air cavity and channeling all the energy into discrete structural paths. The work presented here is a first step towards the goal of designing a high-loss, actively-controlled double-leaf partition with an air-evacuated inner chamber. One experiment is conducted to investigate the effects of various levels of vacuum on the response of a double-leaf partition whose panels are mechanically coupled only at the boundary. Another experiment is conducted which investigates the effect of changing the stiffness of an intermediate support coupling the two panels of a double-leaf partition in which a vacuum has been applied to the inner cavity. The available equipment was able to maintain a 99% vacuum between the panels. Both experiments are accompanied by analytical models used to investigate the importance of various dynamic parameters. Results show that the vacuum-sealed system shows some potential for increased transmission loss, primarily by the changing the natural frequencies of the double-leaf partition.

  1. A novel power converter for photovoltaic applications

    NASA Astrophysics Data System (ADS)

    Yuvarajan, S.; Yu, Dachuan; Xu, Shanguang

    A simple and economical power conditioner to convert the power available from solar panels into 60 Hz ac voltage is described. The raw dc voltage from the solar panels is converted to a regulated dc voltage using a boost converter and a large capacitor and the dc output is then converted to 60 Hz ac using a bridge inverter. The ratio between the load current and the short-circuit current of a PV panel at maximum power point is nearly constant for different insolation (light) levels and this property is utilized in designing a simple maximum power point tracking (MPPT) controller. The controller includes a novel arrangement for sensing the short-circuit current without disturbing the operation of the PV panel and implementing MPPT. The switching losses in the inverter are reduced by using snubbers. The results obtained on an experimental converter are presented.

  2. Modeling and stability of segmented reflector telescopes - A decentralized approach

    NASA Technical Reports Server (NTRS)

    Ryaciotaki-Boussalis, Helen A.; Ih, Che-Hang Charles

    1990-01-01

    The decentralization of a segmented reflector telescope based on a finite-element model of its structure is considered. The decentralization of the system at the panel level is considered. Each panel is originally treated as an isolated subsystem so that the controller design is performed independently at the local level, and then applied to the composite system for stability analysis. The panel-level control laws were designed by means of pole placement using local output feedback. Simulation results show a better 1000:1 vibration attenuation in panel position when compared to the open-loop system. It is shown that the overall closed-loop system is exponentially stable provided that certain conditions are met. The advantage to the decentralized approach is that the design is performed in terms of the low-dimensionality subsystems, thus drastically reducing the design computational complexities.

  3. A panel of ancestry informative markers to estimate and correct potential effects of population stratification in Han Chinese.

    PubMed

    Qin, Pengfei; Li, Zhiqiang; Jin, Wenfei; Lu, Dongsheng; Lou, Haiyi; Shen, Jiawei; Jin, Li; Shi, Yongyong; Xu, Shuhua

    2014-02-01

    Population stratification acts as a confounding factor in genetic association studies and may lead to false-positive or false-negative results. Previous studies have analyzed the genetic substructures in Han Chinese population, the largest ethnic group in the world comprising ∼20% of the global human population. In this study, we examined 5540 Han Chinese individuals with about 1 million single-nucleotide polymorphisms (SNPs) and screened a panel of ancestry informative markers (AIMs) to facilitate the discerning and controlling of population structure in future association studies on Han Chinese. Based on genome-wide data, we first confirmed our previous observation of the north-south differentiation in Han Chinese population. Second, we developed a panel of 150 validated SNP AIMs to determine the northern or southern origin of each Han Chinese individual. We further evaluated the performance of our AIMs panel in association studies in simulation analysis. Our results showed that this AIMs panel had sufficient power to discern and control population stratification in Han Chinese, which could significantly reduce false-positive rates in both genome-wide association studies (GWAS) and candidate gene association studies (CGAS). We suggest this AIMs panel be genotyped and used to control and correct population stratification in the study design or data analysis of future association studies, especially in CGAS which is the most popular approach to validate previous reports on genetic associations of diseases in post-GWAS era.

  4. Associations between alcohol outlets and emergency department injury presentations: effects of distance from the central business district.

    PubMed

    Hobday, Michelle; Meuleners, Lynn; Liang, Wenbin; Gilmore, William; Chikritzhs, Tanya

    2016-02-01

    To examine the effects of licensed outlets and sales on levels of alcohol-related injuries presenting to emergency departments (EDs) in the Inner, Middle and Outer postcode zones of Perth, Australia. Using panel data (2002-2010), a surrogate measure (based on day of week and time of day of presentation) was used to identify alcohol-related injuries presenting at EDs. Postcodes were grouped according to their distance from the central business district (CBD). Numbers of alcohol outlets and their sales were the primary explanatory variables. Data were analysed using negative binomial regression with random effects. In the Inner and Outer postcode zones, counts of on-site outlets were positively associated with alcohol-related injury (IRR: 1.008; 95%CI 1.003-1.013 and IRR: 1.021; 95%CI 1.013-1.030 respectively). An additional off-site outlet was associated with 6.8% fewer alcohol-related injuries (95%CI 0.887-0.980). In the Middle postcode zone, mean off-site sales were positively associated with injury (IRR: 1.024; 95%CI 1.003-1.044). Associations between alcohol availability variables and injury differed by outlet type and distance from the CBD. These findings provide further evidence to support stronger controls on liquor licensing, and indicate the need for different controls according to the location and type of licence. © 2015 Public Health Association of Australia.

  5. Nonlinear Dynamics and Bifurcation Analysis of a Boost Converter for Battery Charging in Photovoltaic Applications

    NASA Astrophysics Data System (ADS)

    Al-Hindawi, Mohammed M.; Abusorrah, Abdullah; Al-Turki, Yusuf; Giaouris, Damian; Mandal, Kuntal; Banerjee, Soumitro

    Photovoltaic (PV) systems with a battery back-up form an integral part of distributed generation systems and therefore have recently attracted a lot of interest. In this paper, we consider a system of charging a battery from a PV panel through a current mode controlled boost dc-dc converter. We analyze its complete nonlinear/nonsmooth dynamics, using a piecewise model of the converter and realistic nonlinear v-i characteristics of the PV panel. Through this study, it is revealed that system design without taking into account the nonsmooth dynamics of the converter combined with the nonlinear v-i characteristics of the PV panel can lead to unpredictable responses of the overall system with high current ripple and other undesirable phenomena. This analysis can lead to better designed converters that can operate under a wide variation of the solar irradiation and the battery's state of charge. We show that the v-i characteristics of the PV panel combined with the battery's output voltage variation can increase or decrease the converter's robustness, both under peak current mode control and average current mode control. We justify the observation in terms of the change in the discrete-time map caused by the nonlinear v-i characteristics of the PV panel. The theoretical results are validated experimentally.

  6. VIEW OF CONTROL PANEL (RIGHT) AT THE GROUND FLOOR LEVEL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CONTROL PANEL (RIGHT) AT THE GROUND FLOOR LEVEL AND SIDE OF THE MISSILE TUBE (FOREGROUND). VIEW FACING EAST - U.S. Naval Base, Pearl Harbor, Ford Island Polaris Missile Lab & U.S. Fleet Ballistic Missile Submarine Training Center, Between Lexington Boulvevard and the sea plane ramps on the southwest side of Ford Island, Pearl City, Honolulu County, HI

  7. 75 FR 9207 - Notice of a Project Waiver of Section 1605 (Buy American Requirement) of the American Recovery...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-01

    ... the purchase of a GrundFos SQ Flex 6 SQF- 2 solar powered submersible pump system with control and solar panels (pump system) manufactured in Denmark by GrundFos. This is a project specific waiver and... powered submersible pump system with control and solar panels (pump system) manufactured in Denmark by...

  8. 76 FR 19795 - Exelon Generation Company, LLC; Oyster Creek Nuclear Generating Station; Exemption

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... Recirculation and close V-11- Motor Generator 63 and V-11-41. (MG) Set Room Elev. 23'-6''. Manually open V- 12... ``Alternate'' and operate Control Switch on Diesel Panel to start diesel). Manually re-close 6 MCC 1B32 Feeder... transfer Switches (3 total) to ``Alternate'' and operate Control Switch on Diesel Panel to start diesel...

  9. STS-43 Pilot Baker eats a sandwich on OV-104's forward flight deck

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-43 Pilot Michael A. Baker, seated at the forward flight deck pilots station controls, eats a freefloating peanut butter and jelly sandwich while holding a carrot. Surrounding Baker on Atlantis', Orbiter Vehicle (OV) 104's, flight deck are procedural checklists, control panels, and windows. A lemonade drink bag is velcroed to overhead panel O9.

  10. Deliberating Tarceva: A case study of how British NHS managers decide whether to purchase a high-cost drug in the shadow of NICE guidance.

    PubMed

    Hughes, David; Doheny, Shane

    2011-11-01

    This paper examines audio-recorded data from meetings in which NHS managers decide whether to fund high-cost drugs for individual patients. It investigates the work of a Welsh individual patient commissioning (IPC) panel responsible for sanctioning the purchase of 'un-commissioned' treatments for exceptional cases. The case study presented highlights the changing rationales used for approving or denying a cancer drug, Tarceva, during a period when NICE first suggested it was not cost effective, but then changed its position in a final technology appraisal recommending use when the cost did not exceed that of an alternative product. Our data show how decisions taken in the shadow of NICE guidance remain complex and subject to local discretion. Guidance that takes time to prepare, is released in stages, and relates to particular disease stages, must be interpreted in the context of particular cases. The case-based IPC panel discourse stands in tension with the standardised population-based recommendations in guidance. Panel members, who based their decisions on the central notions of 'efficacy' and 'exceptionality', often struggled to apply NICE information on cost-effectiveness to their deliberations on efficacy (clinical effectiveness). The case study suggests that the complex nature of decision making makes standardization of outcomes very difficult to achieve, so that local professional judgement is likely to remain central to health care rationing at this level. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Postbuckling behavior of axially compressed graphite-epoxy cylindrical panels with circular holes

    NASA Technical Reports Server (NTRS)

    Knight, N. F., Jr.; Starnes, J. H., Jr.

    1984-01-01

    The results of an experimental and analytical study of the effects of circular holes on the postbuckling behavior of graphite-epoxy cylindrical panels loaded in axial compression are presented. The STAGSC-1 general shell analysis computer code is used to determine the buckling and postbuckling response of the panels. The loaded, curved ends of the specimens were clamped by fixtures and the unloaded, straight edges were simply supported by knife-edge restraints. The panels are loaded by uniform end shortening to several times the end shortening at buckling. The unstable equilibrium path of the postbuckling response is obtained analytically by using a method based on controlling an equilibrium-path-arc-length parameter instead of the traditional load parameter. The effects of hole diameter, panel radius, and panel thickness on postbuckling response are considered in the study. Experimental results are compared with the analytical results and the failure characteristics of the graphite-epoxy panels are described.

  12. 78 FR 72684 - National Institute of Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-03

    ... Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting Pursuant to section 10(d) of the... Diabetes and Digestive and Kidney Diseases Special Emphasis Panel; PAR11-306: NIDDK Central Repositories..., Endocrinology and Metabolic Research; 93.848, Digestive Diseases and Nutrition Research; 93.849, Kidney Diseases...

  13. 76 FR 17658 - National Institute of Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting Pursuant to section 10(d) of the... Diabetes and Digestive and Kidney Diseases Special Emphasis Panel; NIDDK Central Repositories Non-Renewable... and Nutrition Research; 93.849, Kidney Diseases, Urology and Hematology Research, National Institutes...

  14. Do Residential Conditions Explain the Relationship between Living Arrangements and Adolescent Behavior?

    ERIC Educational Resources Information Center

    Crowder, Kyle; Teachman, Jay

    2004-01-01

    Persistent effects of childhood living arrangements and family change on adolescent outcomes have often been attributed to differences in socialization and intrafamily processes. We use data from the Panel Study of Income Dynamics to assess an alternative explanation: that neighborhood context and residential mobility represent a central set of…

  15. Central Regional Annual Research Conference in Agricultural Education Proceedings (41st, Chicago, Illinois, February 22-23, 1987).

    ERIC Educational Resources Information Center

    Michigan State Univ., East Lansing. Dept. of Agricultural and Extension Education.

    This proceedings contains 18 papers on agricultural research issues selected by panel review plus the keynote address, a conference summary, and the conference agenda. The following papers are included: "Research in Agricultural Education: Requisites for Further Progress" (Warmbrod--keynote address); "Marketing Agricultural Education" (Casey,…

  16. Speaking Out for Language: Why Language Is Central to Reading Development

    ERIC Educational Resources Information Center

    Dickinson, David K.; Golinkoff, Roberta M.; Hirsh-Pasek, Kathy

    2010-01-01

    Although the National Early Literacy Panel report provides an important distillation of research, the manner in which the data are reported underrepresents the importance of language. Unlike other predictors with moderate associations with later reading, language exerts pervasive and indirect influences that are not described by the effect sizes…

  17. Modeling Cooperation in an Address-Register-Based Telephone/Face-to-Face Survey

    ERIC Educational Resources Information Center

    Lipps, Oliver

    2016-01-01

    I analyze the effects of household sociodemography, interviewer performance in the current survey, and fieldwork characteristics on cooperation in a central telephone survey, where households with no publicly listed landline number receive face-to-face visits. Using the 2013 refreshment sample of the Swiss Household Panel, I employ…

  18. Extensive Aspartoacylase Expression in the Rat Central Nervous System

    DTIC Science & Technology

    2011-01-01

    pathways are shown in panel (A) including the corpus callosum (cc), anterior com- missure (see also C; aco), and fornix ( fx ). The subfornical organ (sfo...14 MOFFETT ET AL. GLIA protein. That antibody and the one used in the current study both stained the same cellular elements. Astro - cytes were the

  19. Identifying a Core Set of Science Teaching Practices: A Delphi Expert Panel Approach

    ERIC Educational Resources Information Center

    Kloser, Matthew

    2014-01-01

    The "Framework for K-12 Science Education" details ambitious goals for students' learning of science content and practices. However, this document provides science teachers little guidance about instructional practices that are central to helping students achieve these goals. Research indicates that a teacher's instructional…

  20. 75 FR 18499 - The Effects of Mountaintop Mines and Valley Fills on Aquatic Ecosystems of the Central...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-12

    ... environmental permitting requirements for Appalachian mountaintop removal and other surface coal mining projects.../guidance/mining.html ). Both documents will be reviewed by an independent review panel convened by EPA's... the state of the science on the ecological impacts of Mountaintop Mining and Valley Fill (MTM-VF...

  1. Development and Validation of the Conceptual Assessment of Natural Selection (CANS)

    ERIC Educational Resources Information Center

    Kalinowski, Steven T.; Leonard, Mary J.; Taper, Mark L.

    2016-01-01

    We developed and validated the Conceptual Assessment of Natural Selection (CANS), a multiple-choice test designed to assess how well college students understand the central principles of natural selection. The expert panel that reviewed the CANS concluded its questions were relevant to natural selection and generally did a good job sampling the…

  2. Novel Human Radiation Exposure Biomarker Panel Applicable for Population Triage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bazan, Jose G.; Chang, Polly; Balog, Robert

    2014-11-01

    Purpose: To identify a panel of radiation-responsive plasma proteins that could be used in a point-of-care biologic dosimeter to detect clinically significant levels of ionizing radiation exposure. Methods and Materials: Patients undergoing preparation for hematopoietic cell transplantation using radiation therapy (RT) with either total lymphoid irradiation or fractionated total body irradiation were eligible. Plasma was examined from patients with potentially confounding conditions and from normal individuals. Each plasma sample was analyzed for a panel of 17 proteins before RT was begun and at several time points after RT exposure. Paired and unpaired t tests between the dose and control groupsmore » were performed. Conditional inference trees were constructed based on panels of proteins to compare the non-RT group with the RT group. Results: A total of 151 patients (62 RT, 41 infection, 48 trauma) were enrolled on the study, and the plasma from an additional 24 healthy control individuals was analyzed. In comparison with to control individuals, tenascin-C was upregulated and clusterin was downregulated in patients receiving RT. Salivary amylase was strongly radiation responsive, with upregulation in total body irradiation patients and slight downregulation in total lymphoid irradiation patients compared with control individuals. A panel consisting of these 3 proteins accurately distinguished between irradiated patients and healthy control individuals within 3 days after exposure: 97% accuracy, 0.5% false negative rate, 2% false positive rate. The accuracy was diminished when patients with trauma, infection, or both were included (accuracy, 74%-84%; false positive rate, 14%-33%, false negative rate: 8%-40%). Conclusions: A panel of 3 proteins accurately distinguishes unirradiated healthy donors from those exposed to RT (0.8-9.6 Gy) within 3 days of exposure. These findings have significant implications in terms of triaging individuals in the case of nuclear or other radiologic events.« less

  3. Novel human radiation exposure biomarker panel applicable for population triage.

    PubMed

    Bazan, Jose G; Chang, Polly; Balog, Robert; D'Andrea, Annalisa; Shaler, Thomas; Lin, Hua; Lee, Shirley; Harrison, Travis; Shura, Lei; Schoen, Lucy; Knox, Susan J; Cooper, David E

    2014-11-01

    To identify a panel of radiation-responsive plasma proteins that could be used in a point-of-care biologic dosimeter to detect clinically significant levels of ionizing radiation exposure. Patients undergoing preparation for hematopoietic cell transplantation using radiation therapy (RT) with either total lymphoid irradiation or fractionated total body irradiation were eligible. Plasma was examined from patients with potentially confounding conditions and from normal individuals. Each plasma sample was analyzed for a panel of 17 proteins before RT was begun and at several time points after RT exposure. Paired and unpaired t tests between the dose and control groups were performed. Conditional inference trees were constructed based on panels of proteins to compare the non-RT group with the RT group. A total of 151 patients (62 RT, 41 infection, 48 trauma) were enrolled on the study, and the plasma from an additional 24 healthy control individuals was analyzed. In comparison with to control individuals, tenascin-C was upregulated and clusterin was downregulated in patients receiving RT. Salivary amylase was strongly radiation responsive, with upregulation in total body irradiation patients and slight downregulation in total lymphoid irradiation patients compared with control individuals. A panel consisting of these 3 proteins accurately distinguished between irradiated patients and healthy control individuals within 3 days after exposure: 97% accuracy, 0.5% false negative rate, 2% false positive rate. The accuracy was diminished when patients with trauma, infection, or both were included (accuracy, 74%-84%; false positive rate, 14%-33%, false negative rate: 8%-40%). A panel of 3 proteins accurately distinguishes unirradiated healthy donors from those exposed to RT (0.8-9.6 Gy) within 3 days of exposure. These findings have significant implications in terms of triaging individuals in the case of nuclear or other radiologic events. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Higher DEFB4 genomic copy number in SLE and ANCA-associated small vasculitis.

    PubMed

    Zhou, Xu-Jie; Cheng, Fa-Juan; Lv, Ji-Cheng; Luo, Huan; Yu, Feng; Chen, Min; Zhao, Ming-Hui; Zhang, Hong

    2012-06-01

    Evidence shows that defensins are involved in the pathogenesis of SLE and ANCA-associated small vasculitis (AASV). The copy number variation of DEFB4 has been proposed to be susceptible to inflammatory disorders. This study aims to investigate whether the DEFB4 genomic copy number variations associate with the susceptibility to these two autoimmune diseases. A total of 1178 Chinese people were enrolled, including panel 1 comprising 240 SLE patients and 275 matched controls, panel 2 comprising 303 SLE patients and 248 matched controls and panel 3 with 112 AASV patients. The DEFB4 copy number was typed by a paralogue ratio test (PRT), and all the subjects in panel 1 were also typed using the restriction enzyme digest variant ratio (REDVR) for validation. The results from PRT and REDVR were highly concordant (R = 0.911, P = 3.85 × 10(-199)) and allowed copy numbers to be assigned into integer classes with high confidence. Comparison of mean DEFB4 copy number revealed a small increase in cases with SLE both in Panel 1 (P = 0.063) and Panel 2 (P = 0.017). When pooling panels 1 and 2 together, the association was reinforced (P = 0.002) in SLE. Such association was also observed in AASV (P = 0.009). We found that a higher DEFB4 gene copy number was associated with both SLE and AASV.

  5. Computational and experimental studies of microvascular void features for passive-adaptation of structural panel dynamic properties

    NASA Astrophysics Data System (ADS)

    Sears, Nicholas C.; Harne, Ryan L.

    2018-01-01

    The performance, integrity, and safety of built-up structural systems are critical to their effective employment in diverse engineering applications. In conflict with these goals, harmonic or random excitations of structural panels may promote large amplitude oscillations that are particularly harmful when excitation energies are concentrated around natural frequencies. This contributes to fatigue concerns, performance degradation, and failure. While studies have considered active or passive damping treatments that adapt material characteristics and configurations for structural control, it remains to be understood how vibration properties of structural panels may be tailored via internal material transitions. Motivated to fill this knowledge gap, this research explores an idea of adapting the static and dynamic material distribution of panels through embedded microvascular channels and strategically placed voids that permit the internal movement of fluids within the panels for structural dynamic control. Finite element model and experimental investigations probe how redistributing material in the form of microscale voids influences the global vibration modes and natural frequencies of structural panels. Through parameter studies, the relationships among void shape, number, size, and location are quantified towards their contribution to the changing structural dynamics. For the panel composition and boundary conditions considered in this report, the findings reveal that transferring material between strategically placed voids may result in eigenfrequency changes as great as 10.0, 5.0, and 7.4% for the first, second, and third modes, respectively.

  6. KENNEDY SPACE CENTER, FLA. - Local Central Florida television reporters Phil Robertson (left), with WFTV, and Dan Billow (right), with WESH, tape commentaries after a media tour of the Orbiter Processing Facility. The media was invited to see the orbiter Atlantis as it is being prepared for Return to Flight. Both local and national reporters representing print and TV networks were able to see work in progress on Atlantis, including the reinstallation of the Reinforced Carbon-Carbon panels on the orbiter’s wing leading edge; wiring inspections; and checks of the engines in the Orbital Maneuvering System.

    NASA Image and Video Library

    2003-09-26

    KENNEDY SPACE CENTER, FLA. - Local Central Florida television reporters Phil Robertson (left), with WFTV, and Dan Billow (right), with WESH, tape commentaries after a media tour of the Orbiter Processing Facility. The media was invited to see the orbiter Atlantis as it is being prepared for Return to Flight. Both local and national reporters representing print and TV networks were able to see work in progress on Atlantis, including the reinstallation of the Reinforced Carbon-Carbon panels on the orbiter’s wing leading edge; wiring inspections; and checks of the engines in the Orbital Maneuvering System.

  7. [Analysis of color gamut of LCD system based on LED backlight with area-controlling technique].

    PubMed

    Li, Fu-Wen; Jin, Wei-Qi; Shao, Xi-Bin; Zhang, Li-Lei; Wan, Li-Fang

    2010-05-01

    Color gamut as a significant performance index for display system describes the color reproduction ability IN real scenes. Liquid crystal display (LCD) is the most popular technology in flat panel display. However, conventional cold cathode fluorescent lamp (CCFL) backlight of LCD can not behave high color gamut compared with cathode ray tube (CRT). The common used method of color gamut measuring for LCD system is introduced at the beginning. According to the inner structure and display principle of LCD system, there are three major factors deciding LCD's color gamut: spectral properties of backlight, transmittance properties of color filters and performance of liquid crystal panel. Instead of conventional backlight CCFL, RGB-LED backlight is used for improving color reproduction of LCD display system. Due to the imperfect match between RGB-LED' s spectra and color filter's transmittance, the color filter would reduce the color gamut of LCD system more or less. Therefore, LCD system based on LED backlight with area-control technique is introduced which modifies backlight control signal according to the input signal After analyzing and calculating the spectra of LED backlight which passes through the color filters using method of colorimetry, the area sizes of color gamut triangles of RGB-LED backlight with area-control and RGB-LED backlight without area-control LCD systems are compared and the relationship between color gamut and varying contrast of liquid crystal panel is analyzed. It is indicated that LED backlight with area-control technique can avoid color saturation dropping and have little effects on the contrast variation of liquid crystal panel. In other words, LED backlight with area-control technique relaxes the requirements of both color filter performance and liquid crystal panel. Thus, it is of importance to improve the color gamut of the current LCD system with area-control LED backlight.

  8. Investigation on the Acoustic Absorption of Flexible Micro-Perforated Panel with Ultra-Micro Perforations

    NASA Astrophysics Data System (ADS)

    Li, Guoxin; Tang, Xiaoning; Zhang, Xiaoxiao; Qian, Y. J.; Kong, Deyi

    2017-11-01

    Flexible micro-perforated panel has unique advantages in noise reduction due to its good flexibility compared with traditional rigid micro-perforated panel. In this paper, flexible micro-perforated panel was prepared by computer numerical control (CNC) milling machine. Three kinds of plastics including polyvinylchloride (PVC), polyethylene terephthalate (PET), and polyimide (PI) were taken as the matrix materials to prepare flexible micro-perforated panel. It has been found that flexible micro-perforated panel made of PET possessing good porosity and proper density, elastic modulus and poisson ratio exhibited the best acoustic absorption properties. The effects of various structural parameters including perforation diameter, perforation ratio, thickness and air gap have also been investigated, which would be helpful to the optimization of acoustic absorption properties.

  9. High Step-Up DC—DC Converter for AC Photovoltaic Module with MPPT Control

    NASA Astrophysics Data System (ADS)

    Sundar, Govindasamy; Karthick, Narashiman; Rama Reddy, Sasi

    2014-08-01

    This paper presents the high gain step-up BOOST converter which is essential to step up the low output voltage from PV panel to the high voltage according to the requirement of the application. In this paper a high gain BOOST converter with coupled inductor technique is proposed with the MPPT control. Without extreme duty ratios and the numerous turns-ratios of a coupled inductor this converter achieves a high step-up voltage-conversion ratio and the leakage energy of the coupled inductor is efficiently recycled to the load. MPPT control used to extract the maximum power from PV panel by controlling the Duty ratio of the converter. The PV panel, BOOST converter and the MPPT are modeled using Sim Power System blocks in MATLAB/SIMULINK environment. The prototype model of the proposed converter has been implemented with the maximum measured efficiency is up to 95.4% and full-load efficiency is 93.1%.

  10. Autoantibody Approach for Serum-Based Detection of Head and Neck Cancer — EDRN Public Portal

    Cancer.gov

    Our long term goal is to improve survival of patients with head and neck squamous cell carcinoma (HNSCC) through early detection using simple noninvasive serum assays in an ELISA-like platform. The objective of this proposal is to improve and confirm the validity of a diagnostic serum assay based on a panel of cancer-specific biomarkers for early cancer detection in patients with HNSCC. Our central hypothesis is that the detection of antibody responses to HNSCC-specific antigens, using a panel of biomarkers, can provide sufficient sensitivity and specificity suitable for clinical testing in the primary setting to screen and diagnose HNSCC in high risk populations to improve early detection.

  11. Congenital neutropenia in the era of genomics: classification, diagnosis, and natural history.

    PubMed

    Donadieu, Jean; Beaupain, Blandine; Fenneteau, Odile; Bellanné-Chantelot, Christine

    2017-11-01

    This review focuses on the classification, diagnosis and natural history of congenital neutropenia (CN). CN encompasses a number of genetic disorders with chronic neutropenia and, for some, affecting other organ systems, such as the pancreas, central nervous system, heart, bone and skin. To date, 24 distinct genes have been associated with CN. The number of genes involved makes gene screening difficult. This can be solved by next-generation sequencing (NGS) of targeted gene panels. One of the major complications of CN is spontaneous leukaemia, which is preceded by clonal somatic evolution, and can be screened by a targeted NGS panel focused on somatic events. © 2017 John Wiley & Sons Ltd.

  12. 76 FR 28790 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial review.

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-18

    ... announced below concerns Affordable Care Act (ACA): Childhood Obesity Research Funding Opportunity... ``Affordable Care Act (ACA): Childhood Obesity Research Funding Opportunity Announcement (FOA) DP11-007, Panel...

  13. Panel flutter optimization by gradient projection

    NASA Technical Reports Server (NTRS)

    Pierson, B. L.

    1975-01-01

    A gradient projection optimal control algorithm incorporating conjugate gradient directions of search is described and applied to several minimum weight panel design problems subject to a flutter speed constraint. New numerical solutions are obtained for both simply-supported and clamped homogeneous panels of infinite span for various levels of inplane loading and minimum thickness. The minimum thickness inequality constraint is enforced by a simple transformation of variables.

  14. Development of technology for the fabrication of reliable laminar flow control panels on subsonic transports

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The feasibility of using porous composite materials (Kevlar, Doweave, and Leno Weave) as lightweight, efficient laminar flow control (LFC) surface materials is compared to the metallic 319L stainless Dynapore surfaces and electron beam drilled composite surfaces. Areas investigated include: (1) selection of the LFC-suitable surface materials, structural materials, and fabrication techniques for the LFC aircraft skins; (2) aerodynamic static air flow test results in terms of pressure drop through the LFC panel and the corresponding effective porosity; (3) structural design definition and analyses of the panels, and (4) contamination effects on static drop and effective porosity. Conclusions are presented and discussed.

  15. Luminance uniformity compensation for OLED panels based on FPGA

    NASA Astrophysics Data System (ADS)

    Ou, Peng; Yang, Gang; Jiang, Quan; Yu, Jun-Sheng; Wu, Qi-Peng; Shang, Fu-Hai; Yin, Wei; Wang, Jun; Zhong, Jian; Luo, Kai-Jun

    2009-09-01

    Aiming at the problem of luminance uniformity for organic lighting-emitting diode (OLED) panels, a new brightness calculating method based on bilinear interpolation is proposed. The irradiance time of each pixel reaching the same luminance is figured out by Matlab. Adopting the 64×32-pixel, single color and passive matrix OLED panel as adjusting luminance uniformity panel, a new circuit compensating scheme based on FPGA is designed. VHDL is used to make each pixel’s irradiance time in one frame period written in program. The irradiance brightness is controlled by changing its irradiance time, and finally, luminance compensation of the panel is realized. The simulation result indicates that the design is reasonable.

  16. Payload bay doors and radiator panels familiarization handbook

    NASA Technical Reports Server (NTRS)

    Godbold, John A.

    1992-01-01

    The structure and mechanisms associated with the Payload Bay Doors (PLBDs) and the radiator panels are detailed. The PLBDs allow the radiator panels to be exposed to space, protect payloads from contamination, and provide an aerodynamic fairing over the payload bay. The radiator panels dissipate heat from the orbiter and regulate hydraulic fluid temperature. Contamination in the payload bay can hinder the success of missions. Therefore, the contamination control barrier which the PLBDs provide must be efficient in keeping the bay free from contaminants. The aerodynamic fairing the PLBDs provide prevents the orbiter from being torn apart by aerodynamic forces. These facts make the PLBDs and radiator panels mission critical elements of the Space Shuttle.

  17. A broad investigation of the HBV-mediated changes to primary hepatocyte physiology reveals HBV significantly alters metabolic pathways.

    PubMed

    Lamontagne, R Jason; Casciano, Jessica C; Bouchard, Michael J

    2018-06-01

    As the leading risk factor for the development of liver cancer, chronic infection with hepatitis B virus (HBV) represents a significant global health concern. Although an effective HBV vaccine exists, at least 240 million people are chronically infected with HBV worldwide. Therapeutic options for the treatment of chronic HBV remain limited, and none achieve an absolute cure. To develop novel therapeutic targets, a better understanding of the complex network of virus-host interactions is needed. Because of the central metabolic role of the liver, we assessed the metabolic impact of HBV infection as a means to identify viral dependency factors and metabolic pathways that could serve as novel points of therapeutic intervention. Primary rat hepatocytes were infected with a control adenovirus, an adenovirus expressing a greater-than-unit-length copy of the HBV genome, or an adenovirus expressing the HBV X protein (HBx). A panel of 369 metabolites was analyzed for HBV- or HBx-induced changes 24 and 48 h post infection. Pathway analysis was used to identify key metabolic pathways altered in the presence of HBV or HBx expression, and these findings were further supported through integration of publically available gene expression data. We observed distinct changes to multiple metabolites in the context of HBV replication or HBx expression. Interestingly, a panel of 7 metabolites (maltotriose, maltose, myristate [14:0], arachidate [20:0], 3-hydroxybutyrate [BHBA], myo-inositol, and 2-palmitoylglycerol [16,0]) were altered by both HBV and HBx at both time points. In addition, incorporation of data from a transcriptome-based dataset allowed us to identify metabolic pathways, including long chain fatty acid metabolism, glycolysis, and glycogen metabolism, that were significantly altered by HBV and HBx. Because the liver is a central regulator of metabolic processes, it is important to understand how HBV replication and HBV protein expression affects the metabolic function of hepatocytes. Through analysis of a broad panel of metabolites we investigated this metabolic impact. The results of these studies have defined metabolic consequences of an HBV infection of hepatocytes and will help to lay the groundwork for novel research directions and, potentially, development of novel anti-HBV therapeutics. Copyright © 2018. Published by Elsevier Inc.

  18. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDowell, Michael W; Miner, Kris

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then completemore » the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to test scale prototype receiver, off sun but at temperature, at a molten salt loop at ground level adjacent to the tower also had to be abandoned. Thus, no test facility existed for a molten salt receiver test. As a result, PWR completed the prototype receiver design and then fabricated key components for testing instead of fabricating the complete prototype receiver. A number of innovative design ideas have been developed. Key features of the receiver panel have been identified. This evaluation includes input from Solar 2, personal experience of people working on these programs and meetings with Sandia. Key components of the receiver design and key processes used to fabricate a receiver have been selected for further evaluation. The Test Plan, Concentrated Solar Power Receiver In Cooperation with the Department of Energy and Sandia National Laboratory was written to define the scope of the testing to be completed as well as to provide details related to the hardware, instrumentation, and data acquisition. The document contains a list of test objectives, a test matrix, and an associated test box showing the operating points to be tested. Test Objectives: 1. Demonstrate low-cost manufacturability 2. Demonstrate robustness of two different tube base materials 3. Collect temperature data during on sun operation 4. Demonstrate long term repeated daily operation of heat shields 5. Complete pinhole tube weld repairs 6. Anchor thermal models This report discusses the tests performed, the results, and implications for design improvements and LCOE reduction.« less

  19. European Population Substructure: Clustering of Northern and Southern Populations

    PubMed Central

    Seldin, Michael F; Shigeta, Russell; Villoslada, Pablo; Selmi, Carlo; Tuomilehto, Jaakko; Silva, Gabriel; Belmont, John W; Klareskog, Lars; Gregersen, Peter K

    2006-01-01

    Using a genome-wide single nucleotide polymorphism (SNP) panel, we observed population structure in a diverse group of Europeans and European Americans. Under a variety of conditions and tests, there is a consistent and reproducible distinction between “northern” and “southern” European population groups: most individual participants with southern European ancestry (Italian, Spanish, Portuguese, and Greek) have >85% membership in the “southern” population; and most northern, western, eastern, and central Europeans have >90% in the “northern” population group. Ashkenazi Jewish as well as Sephardic Jewish origin also showed >85% membership in the “southern” population, consistent with a later Mediterranean origin of these ethnic groups. Based on this work, we have developed a core set of informative SNP markers that can control for this partition in European population structure in a variety of clinical and genetic studies. PMID:17044734

  20. The impact of regime type on health: does redistribution explain everything?

    PubMed

    Wigley, Simon; Akkoyunlu-Wigley, Arzu

    2011-01-01

    Many scholars claim that democracy improves population health. The prevailing explanation for this is that democratic regimes distribute health-promoting resources more widely than autocratic regimes. The central contention of this article is that democracies also have a significant pro-health effect regardless of public redistributive policies. After establishing the theoretical plausibility of the nondistributive effect, a panel of 153 countries for the years 1972 to 2000 is used to examine the relationship between extent of democratic experience and life expectancy. The authors find that democratic governance continues to have a salutary effect on population health even when controls are introduced for the distribution of health-enhancing resources. Data for fifty autocratic countries for the years 1994 to 2007 are then used to examine whether media freedom—independent of government responsiveness—has a positive impact on life expectancy.

  1. Flow regions of granules in Dorfan Impingo filter for gas cleanup

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuo, J.T.; Smid, J.; Hsiau, S.S.

    1999-07-01

    Inside a two-dimensional model of the louvered Dorfan Impingo panel with transparent front and rear walls the flow region of filter granules without gas cross flow were observed. The white PE beads were used as filter granules. Colored PE beads served as tracers. Filter granules were discharged and circulated to the bed. The flow rate of filter medium was controlled by the belt conveyor. The image processing system including a Frame Grabber and JVC videocamera was used to record the granular flow. Every image of motion was digitized and stored in a file. The flow patterns and the quasi-stagnant zonesmore » history in the moving granular bed were evaluated. The experiment showed fast central moving region (flowing core) of filter granules and quasi-stagnant zones close to louver walls.« less

  2. Physical mechanisms of active control of sound transmission through rib stiffened double-panel structure

    NASA Astrophysics Data System (ADS)

    Ma, Xiyue; Chen, Kean; Ding, Shaohu; Yu, Haoxin

    2016-06-01

    This paper presents an analytical investigation on physical mechanisms of actively controlling sound transmission through a rib stiffened double-panel structure using point source in the cavity. The combined modal expansion and vibro-acoustic coupling methods are applied to establish the theoretical model of such active structure. Under the condition of minimizing radiated power of the radiating ribbed plate, the physical mechanisms are interpreted in detail from the point of view of modal couplings similar as that used in existed literatures. Results obtained demonstrate that the rule of sound energy transmission and the physical mechanisms for the rib stiffened double-panel structure are all changed, and affected by the coupling effects of the rib when compared with the analytical results obtained for unribbed double-panel case. By taking the coupling effects of the rib into considerations, the cavity modal suppression and rearrangement mechanisms obtained in existed investigations are modified and supplemented for the ribbed plate case, which gives a clear interpretation for the physical nature involved in the active rib stiffened double-panel structure.

  3. Structural Acoustic Response of a Shape Memory Alloy Hybrid Composite Panel (Lessons Learned)

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.

    2002-01-01

    This study presents results from an effort to fabricate a shape memory alloy hybrid composite (SMAHC) panel specimen and test the structure for dynamic response and noise transmission characteristics under the action of thermal and random acoustic loads. A method for fabricating a SMAHC laminate with bi-directional SMA reinforcement is described. Glass-epoxy unidirectional prepreg tape and Nitinol ribbon comprise the material system. Thermal activation of the Nitinol actuators was achieved through resistive heating. The experimental hardware required for mechanical support of the panel/actuators and for establishing convenient electrical connectivity to the actuators is presented. Other experimental apparatus necessary for controlling the panel temperature and acquiring structural acoustic data are also described. Deficiency in the thermal control system was discovered in the process of performing the elevated temperature tests. Discussion of the experimental results focuses on determining the causes for the deficiency and establishing means for rectifying the problem.

  4. Structural acoustic response of a shape memory alloy hybrid composite panel (lessons learned)

    NASA Astrophysics Data System (ADS)

    Turner, Travis L.

    2002-07-01

    This study presents results from an effort to fabricate a shape memory alloy hybrid composite (SMAHC) panel specimen and test the structure for dynamic response and noise transmission characteristics under the action of thermal and random acoustic loads. A method for fabricating a SMAHC laminate with bi-directional SMA reinforcement is described. Glass-epoxy unidirectional prepreg tape and Nitinol ribbon comprise the material system. Thermal activation of the Nitinol actuators was achieved through resistive heating. The experimental hardware required for mechanical support of the panel/actuators and for establishing convenient electrical connectivity to the actuators is presented. Other experimental apparatus necessary for controlling the panel temperature and acquiring structural acoustic data are also described. Deficiency in the thermal control system was discovered in the process of performing the elevated temperature tests. Discussion of the experimental results focuses on determining the causes for the deficiency and establishing means for rectifying the problem.

  5. Using a Fuzzy Light Sensor to Improve the Efficiency of Solar Panels

    NASA Astrophysics Data System (ADS)

    Suryono; Suseno, Jatmiko Endro; Sulistiati, Ainie Khuriati Riza; Prahara, Tahan

    2018-02-01

    Solar panel efficiency can be increased by improving the quality of photovoltaic material, the effectiveness of electronic circuit, and the light source tracking model. This research is aimed at improving the quality of solar panels by tracking light source using a fuzzy logic sensor. A fuzzy light sensor property is obtained from two LDR (light dependent resistor) light sensors installed in parallel to each other and is given a light separator in between them. Both sensors are mounted on a solar panel. Sensor output is acquired using a 12 bit ADC from an ATSAM3XE microcontroller and is then sent to a computer using WIFI radio. A PID (Proportional-Integral-Derivative) control algorithm is used to manage the position of the solar panel in line with the input given by the fuzzy light sensor. This control mechanism works based on the margin of fuzzy membership from both sensors that is used to move a motor DC that in turn moves the solar panel. Experimental results show a characteristically symmetrical fuzzy membership of both sensors with a reflected correlation of R=0.9981 after gains from both sensors are arranged with a program. Upon being tested in the field, this system was capable of improving the performance of solar panels in gaining power compared to their original fixed position. The discrepancy was evident when the angle of incoming sunlight approached both 0° and 180°. Further calculations of data acquired by the fuzzy light sensor show increased solar panel power efficiency by up to 5.6%.

  6. Interactive Multimedia Distance Learning (IMDL)

    DTIC Science & Technology

    1999-01-01

    scales to their original values. Media Toolbar. The Media Toolbar provides the instructor the ability to choose camera positions, use the whiteboard ...on the classroom server computer. Whiteboard . Activates a whiteboard associated with the MIDL system. The whiteboard is used to annotate the course...button. Media Control Panel. The Media Control Panel allows the instructor to choose a camera position, use the whiteboard , play some computer video, use

  7. 12. CONTROL PANELS, WEST SIDE (LEFT & RIGHT), MAIN FLOOR: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. CONTROL PANELS, WEST SIDE (LEFT & RIGHT), MAIN FLOOR: CENTER OF CLUSTERS, TOP BOX: MEGAWATT METER CENTER OF CLUSTERS, LOWER THREE BOXES: AMPERE METERS LEFT SIDE OF CLUSTERS: VOLTAGE CHART RECORDER RIGHT SIDE OF CLUSTERS: RECLOSE RELAY CENTER UNDER CLUSTERS: TESTING SWITCHES BELOW TESTING SWITCHES: BREAKER SWITCHES - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  8. STS-43 Pilot Baker eats a sandwich on OV-104's forward flight deck

    NASA Image and Video Library

    1991-08-11

    STS043-02-020 (2-11 Aug. 1991) --- Astronaut Michael A. Baker, STS-43 pilot, seated at the forward flight deck pilot station controls of the Space Shuttle Atlantis, eats a free-floating peanut butter and jelly sandwich while holding a carrot. Surrounding Baker are procedural checklists, control panels, and windows. A lemonade drink bag is velcroed to overhead panel.

  9. Characteristics of Clinical Studies Used for US Food and Drug Administration Approval of High-Risk Medical Device Supplements.

    PubMed

    Zheng, Sarah Y; Dhruva, Sanket S; Redberg, Rita F

    2017-08-15

    High-risk medical devices often undergo modifications, which are approved by the US Food and Drug Administration (FDA) through various kinds of premarket approval (PMA) supplements. There have been multiple high-profile recalls of devices approved as PMA supplements. To characterize the quality of the clinical studies and data (strength of evidence) used to support FDA approval of panel-track supplements (a type of PMA supplement pathway that is used for significant changes in a device or indication for use and always requires clinical data). Descriptive study of clinical studies supporting panel-track supplements approved by the FDA between April 19, 2006, and October 9, 2015. Panel-track supplement approval. Methodological quality of studies including randomization, blinding, type of controls, clinical vs surrogate primary end points, use of post hoc analyses, and reporting of age and sex. Eighty-three clinical studies supported the approval of 78 panel-track supplements, with 71 panel-track supplements (91%) supported by a single study. Of the 83 studies, 37 (45%) were randomized clinical trials and 25 (30%) were blinded. The median number of patients per study was 185 (interquartile range, 75-305), and the median follow-up duration was 180 days (interquartile range, 84-270 days). There were a total of 150 primary end points (mean [SD], 1.8 [1.2] per study), and 57 primary end points (38%) were compared with controls. Of primary end points with controls, 6 (11%) were retrospective controls and 51 (89%) were active controls. One hundred twenty-one primary end points (81%) were surrogate end points. Thirty-three studies (40%) did not report age and 25 (30%) did not report sex for all enrolled patients. The FDA required postapproval studies for 29 of 78 (37%) panel-track supplements. Among clinical studies used to support FDA approval of high-risk medical device modifications, fewer than half were randomized, blinded, or controlled, and most primary outcomes were based on surrogate end points. These findings suggest that the quality of studies and data evaluated to support approval by the FDA of modifications of high-risk devices should be improved.

  10. Are the psychosocial aspects of weapons of mass destruction incidents addressed in the Federal Response Plan: summary of an expert panel.

    PubMed

    Becker, S M

    2001-12-01

    Within the domestic preparedness community, there is a growing recognition of the importance of psychosocial issues in weapons of mass destruction (WMD) incidents. Whereas social and behavioral issues were only infrequently considered just a few years ago, they are now coming to be seen as central to consequence management efforts. As a result, discussions in the domestic preparedness community are beginning to consider the extent to which psychosocial effects are addressed in the Federal Response Plan and the degree to which additional preparedness and response steps may be needed. To grapple with this crucial issue, an expert panel was brought together at the International Conference on the Operational Impact of Psychological Casualties from Weapons of Mass Destruction. The panel brought together a wide range of specialists from federal agencies, the armed services, and the academic community. This article summarizes the views and assessments of the panelists as well as their policy recommendations for enhancing preparedness.

  11. ADST Software Design Document for the BDS-D VIDS-equipped M1

    DTIC Science & Technology

    1993-09-10

    system responds to perceived threats in the following ways:I a. by displaying visual icons on the Commander’s Controls Display Panel (CCDP). b. by...also referred to as the Soldier Machine Interface (SMI) and the Commander’s Controls Display Panel (CCDP). 3.2.1. VIDS-GT CSC The VIDS-GT CSC handles...countermeasure will be activated first in Individual_CM_Simul. 4.1.3.4.3. IndividualCMSimul CSU IndividualCM-Simul controls the activation and deactivation of

  12. A 2.2 sq m /24 sq ft/ self-controlled deployable heat pipe radiator - Design and test

    NASA Technical Reports Server (NTRS)

    Edelstein, F.

    1975-01-01

    An all heat pipe, deployable radiator has been developed which can effectively control pumped fluid loop temperatures under varying loads using variable conductance panel heat pipes. The 2.2 sq m (24 sq ft) aluminum panel can be coupled to either a fluid header or a flexible heat pipe header capable of transporting 850 watts in a 90-deg bent configuration. Test results support the feasibility of using this system to passively control Freon-21 loop temperatures.

  13. Sensitivity Analysis of Algan/GAN High Electron Mobility Transistors to Process Variation

    DTIC Science & Technology

    2008-02-01

    delivery system gas panel including both hydride and alkyl delivery modules and the vent/valve configurations [14...Reactor Gas Delivery Systems A basic schematic diagram of an MOCVD reactor delivery gas panel is shown in Figure 13. The reactor gas delivery...system, or gas panel , consists of a network of stainless steel tubing, automatic valves and electronic mass flow controllers (MFC). There are separate

  14. Prediction of Supersonic Store Separation Characteristics Including Fuselage and Stores of Noncircular Cross Section, Volume IV. Appendices C and D, Details of Program II.

    DTIC Science & Technology

    1980-11-01

    act in the sense displayed in Figure 17 of Volume II. All moments are about the store moment center COMMON /ONE/ DELTP(250),FN(250), PNLC (250),SWPPLE...linear loading pressure coefficient of Jth u-velocity panel FN(J) normal force divided by q for Jth u-velocity panel PNLC (J) panel chord through control

  15. The United States Air Force Academy Solar Energy Research

    DTIC Science & Technology

    1980-07-01

    controller, ir the solar sy .4tem, is malfunctioning. Put simply, the house will get cold. lf oh cUrs the occupant will notify civil engineering mainte...with this product has been Revere Copper Laminated Panel Sys - trial uses, condenser tubing, electrical of vital assistance in accumulating the tern...Laminated Panel require water temperatures near the additional components Include tubes,. Construction. In the Revere Panel Sys - boiling point,whereas

  16. Large Deformation Behavior of Long Shallow Cylindrical Composite Panels

    NASA Technical Reports Server (NTRS)

    Carper, Douglas M.; Hyer, Michael W.; Johnson, Eric R.

    1991-01-01

    An exact solution is presented for the large deformation response of a simply supported orthotropic cylindrical panel subjected to a uniform line load along a cylinder generator. The cross section of the cylinder is circular and deformations up to the fully snapped through position are investigated. The orthotropic axes are parallel to the generator and circumferential directions. The governing equations are derived using laminated plate theory, nonlinear strain-displacement relations, and applying variational principles. The response is investigated for the case of a panel loaded exactly at midspan and for a panel with the load offset from midspan. The mathematical formulation is one dimensional in the circumferential coordinate. Solutions are obtained in closed-form. An experimental apparatus was designed to load the panels. Experimental results of displacement controlled tests performed on graphite-epoxy curved panels are compared with analytical predictions.

  17. 138. LIQUID NITROGEN INSTRUMENT PANEL ON EAST WALL OF LIQUID ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    138. LIQUID NITROGEN INSTRUMENT PANEL ON EAST WALL OF LIQUID NITROGEN CONTROL ROOM (115), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  18. 76 FR 28437 - Disease, Disability, and Injury Prevention and Control Special Interest Project (SIP): Initial...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-17

    ... announced below concerns ``Validation of Self-Reported Sleep Surveillance Measures, SIP11-047, Panel E..., discussion, and evaluation of ``Validation of Self-Reported Sleep Surveillance Measures, SIP11-047, Panel E...

  19. An international nanoscience advisory board to improve and harmonize nanotechnology oversight

    NASA Astrophysics Data System (ADS)

    Marchant, Gary E.; White, Andrew

    2011-04-01

    As governments around the world begin to implement regulations aimed at controlling nanotechnology, those regulations should be based upon the best available science, applied as consistently as possible within jurisdictions and, to the extent feasible, across jurisdictions. These goals would be easier to achieve with the creation of an international nanoscience advisory board. Such a body could be modeled on similar international scientific advisory bodies for other issues, such as the Intergovernmental Panel on Climate Change (IPCC) and the Intergovernmental Science-Policy Platform on Biodiversity and Ecosystem Services. Such a body should also take into account lessons learned from these similar organizations. An international nanoscience advisory board could assist regulatory bodies by providing a central source of accurate scientific information about the risks and benefits of nanotechnology, including relevant uncertainties, rather than having each regulatory body make these determinations independently. An international nanoscience advisory board could facilitate harmonization within and between jurisdictions by involving the top experts in the field to produce a centralized knowledge base for regulatory decisions. While an international nanoscience advisory board presents many potential benefits, it also faces significant difficulties, which are best illustrated by examining the history and challenges of existing international science advisory bodies.

  20. TFTR neutral beam control and monitoring for DT operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O`Connor, T.; Kamperschroer, J.; Chu, J.

    1995-12-31

    Record fusion power output has recently been obtained in TFTR with the injection of deuterium and tritium neutral beams. This significant achievement was due in part to the controls, software, and data processing capabilities added to the neutral beam system for DT operations. Chief among these improvements was the addition of SUN workstations and large dynamic data storage to the existing Central Instrumentation Control and Data Acquisition (CICADA) system. Essentially instantaneous look back over the recent shot history has been provided for most beam waveforms and analysis results. Gas regulation controls allowing remote switchover between deuterium and tritium were alsomore » added. With these tools, comparison of the waveforms and data of deuterium and tritium for four test conditioning pulses quickly produced reliable tritium setpoints. Thereafter, all beam conditioning was performed with deuterium, thus saving the tritium supply for the important DT injection shots. The lookback capability also led to modifications of the gas system to improve reliability and to control ceramic valve leakage by backbiasing. Other features added to improve the reliability and availability of DT neutral beam operations included master beamline controls and displays, a beamline thermocouple interlock system, a peak thermocouple display, automatic gas inventory and cryo panel gas loading monitoring, beam notching controls, a display of beam/plasma interlocks, and a feedback system to control beam power based on plasma conditions.« less

  1. Social health insurance and labor market outcomes: evidence from central and eastern Europe, and central Asia.

    PubMed

    Wagstaff, Adam; Moreno-Serra, Rodrigo

    2009-01-01

    The implications of social health insurance (SHI) for labor markets have featured prominently in recent debates over the merits of SHI and general revenue financing. It has been argued that by raising the nonwage component of labor costs, SHI reduces firms' demand for labor, lowers employment levels and net wages, and encourages self-employment and informal working arrangements. At the national level, SHI has been claimed to reduce a country's competitiveness in international markets and to discourage foreign direct investment (FDI). The transition from general revenue finance to SHI that occurred during the 1990s in many of the central and eastern European and central Asian countries provides a unique opportunity to investigate empirically these claims. We employ regression-based generalizations of difference-in-differences (DID) and instrumental variables (IV) on country-level panel data from 28 countries for the period 1990-2004. We find that, controlling for gross domestic product (GDP) per capita, SHI increases (gross) wages by 20%, reduces employment (as a share of the population) by 10%, and increases self-employment by 17%. However, we find no significant effects of SHI on unemployment (registered or self-reported), agricultural employment, a widely used measure of the size of the informal economy, or FDI. We do not claim that our results imply that SHI adoption everywhere must necessarily reduce employment and increase self-employment. Nonetheless, our results ought to serve as a warning to those contemplating shifting the financing of health care from general revenues to a SHI system.

  2. Space Station Engineering and Technology Development. Proceedings of the Panel on Solar Thermodynamics Research and Technology Development, July 31, 1985

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Solar thermodynamics research and technology is reported. Comments on current program activity and future plans with regard to satisfying potential space station electric power generation requirements are provided. The proceedings contain a brief synopsis of the presentations to the panel, including panel comments, and a summary of the panel's observations. Selected presentation material is appended. Onboard maintainability and repair in space research and technology plan, solar thermodynamic research, program performance, onboard U.S. ground based mission control, and technology development rad maps from 10 C to the growth station are addressed.

  3. Buckling Analysis of Anisotropic Curved Panels and Shells with Variable Curvature

    NASA Technical Reports Server (NTRS)

    Jaunky, Navin; Knight, Norman F., Jr.; Ambur, Damodar R.

    1998-01-01

    A buckling formulation for anisotropic curved panels with variable curvature is presented in this paper. The variable curvature panel is assumed to consists of two or more panels of constant but different curvatures. Bezier functions are used as Ritz functions Displacement (C(sup 0)), and slope (C(sup 1)) continuities between segments are imposed by manipulation of the Bezier control points. A first-order shear-deformation theory is used in the buckling formulation. Results obtained from the present formulation are compared with those from finite element simulations and are found to be in good agreement.

  4. Transient analysis of a molten salt central receiver (MSCR) in a solar power plant

    NASA Astrophysics Data System (ADS)

    Joshi, A.; Wang, C.; Akinjiola, O.; Lou, X.; Neuschaefer, C.; Quinn, J.

    2016-05-01

    Alstom is developing solar power tower plants utilizing molten salt as the working fluid. In solar power tower, the molten salt central receiver (MSCR) atop of the tower is constructed of banks of tubes arranged in panels creating a heat transfer surface exposed to the solar irradiation from the heliostat field. The molten salt heat transfer fluid (HTF), in this case 60/40%wt NaNO3-KNO3, flows in serpentine flow through the surface collecting sensible heat thus raising the HTF temperature from 290°C to 565°C. The hot molten salt is stored and dispatched to produce superheated steam in a steam generator, which in turn produces electricity in the steam turbine generator. The MSCR based power plant with a thermal energy storage system (TESS) is a fully dispatchable renewable power plant with a number of opportunities for operational and economic optimization. This paper presents operation and controls challenges to the MSCR and the overall power plant, and the use of dynamic model computer simulation based transient analyses applied to molten salt based solar thermal power plant. This study presents the evaluation of the current MSCR design, using a dynamic model, with emphasis on severe events affecting critical process response, such as MS temperature deviations, and recommend MSCR control design improvements based on the results. Cloud events are the scope of the transient analysis presented in this paper. The paper presents results from a comparative study to examine impacts or effects on key process variables related to controls and operation of the MSCR plant.

  5. 75 FR 57971 - National Institute of Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-23

    ... Diabetes and Digestive and Kidney Diseases; Notice of Closed Meeting Pursuant to section 10(d) of the... Diabetes and Digestive and Kidney Diseases Special Emphasis Panel, Central Repositories Non-Renewable Sample Access (PAR-10-90)--Liver, Kidney, Urological Sciences. Date: October 12, 2010. Time: 2 p.m. to 4...

  6. NASA's Role in Aeronautics: A Workshop. Volume II - Military Aviation.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC. Assembly of Engineering.

    The central task of a 1980 workshop on the role of the National Aeronautics and Space Administration (NASA) in aeronautics was to examine the relationship of NASA's research capabilities to the state of U.S. aviation and to make recommendations about NASA's future role in aeronautics. The findings and recommendations of the Panel on Military…

  7. 75 FR 24568 - Notice of Intent To Seek OMB Approval To Collect Information: Revision of a Form Pertaining to...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-05

    ... Peer Review of ARS Research Projects AGENCY: Agricultural Research Service (ARS), USDA. ACTION: Notice... scientific peer reviews of all research activities conducted by the USDA. The Office manages the ARS peer review system by centrally planning peer panel reviews for ARS research projects on a five-year cycle...

  8. Hardwood genetics and tree improvement - A Midwest USA perspective

    Treesearch

    C. H. Michler; R. Meilan; K. E. Woeste; P. M. Pijut; D. Jacobs; P. Aldrich; J. Glaubitz

    2005-01-01

    Fine hardwood trees in the Central Hardwoods region of the United States are an important resource for the furniture, cabinetry, flooring, modular home, and paneling manufacturing industries. Consumers find wood from these trees to be very desirable because of quality factors such as grain, strength and color. To enhance wood production, tree improvement programs can...

  9. NASA's Role in Aeronautics: A Workshop. Volume VI - Aeronautical Research.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC. Assembly of Engineering.

    The central task of a 1980 workshop on the role of the National Aeronautics and Space Administration (NASA) in aeronautics was to examine the relationship of NASA's research capabilities to the state of U.S. aviation and to make recommendations about NASA's future role in aeronautics. Following a brief introduction, the Overview Panel on…

  10. NASA's Role in Aeronautics: A Workshop. Volume III - Transport Aircraft.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC. Assembly of Engineering.

    The central task of a 1980 workshop on the role of the National Aeronautics and Space Administration (NASA) in aeronautics was to examine the relationship of NASA's research capabilities to the state of U.S. aviation and to make recommendations about NASA's future role in aeronautics. The specific task of the Panel on Transport Aircraft was to…

  11. The Social and Psychological Consequences of Intragenerational Mobility. Working Paper 73.4.

    ERIC Educational Resources Information Center

    Rojek, Dean G.

    The relationship between prior and present socioeconomic status and 10 symptoms of social and psychological stress were examined for mobility effects. The analysis was confined to a 5-year, intragenerational mobility panel from 2 Illinois regions--Putnam County and segments of 3 other adjacent counties in north-central Illinois, and a portion of…

  12. 78 FR 31985 - Atomic Safety and Licensing Board Panel; Before the Licensing Board: G. Paul Bollwerk, III...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-28

    ... authorizes the operation of CBR's existing in situ uranium recovery (ISR) facility near Crawford, Nebraska... operate a satellite ISR facility, the Marsland Expansion Area (MEA) site, which is located in Dawes County, Nebraska, some eleven miles to the southeast of CBR's Crawford central processing facility. In response to...

  13. 8. Several of the rental rooms are joined by doors, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Several of the rental rooms are joined by doors, and each room is accessed from the corridor. Originally, the transoms were glazed. When a central heating/cooling system was installed, the transoms were modified to accommodate air grilles that are supplied by a duct located in the corridor. The five-panel door and wood wainscot are original features. However, the wainscot does not occur in every room. The lath and plaster partitions and the wood flooring are typical of the original construction. Credit GADA/MRM. - Stroud Building, 31-33 North Central Avenue, Phoenix, Maricopa County, AZ

  14. Study of the application of superplastically formed and diffusion bonded (SPF/DB) titanium structure to laminar flow control (LFC) wing design

    NASA Technical Reports Server (NTRS)

    Mcquilkin, F. T.

    1979-01-01

    Eighteen design concepts for a LFC wing cover, using various SPF/DB approaches, were developed. After evaluation of producibility, compatibility with LFC requirements, structural efficiency and fatigue requirements, three candidates were selected for fabrication of demonstration panels. Included were both sandwich and stiffened semi-sandwich panels with slotted and perforated surfaces. Subsequent to the evaluation of the three demonstration panels, one concept was selected for fabrication of a 0.3 x 1.0 meter (12 x 42 inch) feasibility panel. It was a stiffened, semi-sandwich panel with a slotted surface, designed to meet the requirements of the upper wing cover at the maximum wing bending moment of the baseline configuration.

  15. Ergonomic Redesign of an Industrial Control Panel.

    PubMed

    Raeisi, S; Osqueizadeh, R; Maghsoudipour, M; Jafarpisheh, A S

    2016-07-01

    Operator's role in industrial control centers takes place in time, which is one of the most important determinants of whether an expected action is going to be successful or not. In certain situations, due to the complex nature of the work, the existing interfaces and already prepared procedures do not meet the dynamic requirements of operator's cognitive demands, making the control tasks unnecessarily difficult. This study was conducted to identify ergonomic issues with a specific industrial control panel, and redesign its layout and elements to enhance its usability. Task and link analysis methodologies were implemented. All essential functions and supporting operations were identified at the required trivial levels. Next, the weight of any possible link between the elements of the panel was computed as a composite index of frequency and importance. Finally, all components were rearranged within a new layout, and a computerized mockup was generated. A total of 8 primary tasks was identified, including 4 system failure handling tasks, switching between manual and automated modes, and 3 types of routine vigilance and control tasks. These tasks were broken down into 28 functions and 145 supporting operations, accordingly. Higher link values were observed between hand rest position and 2 elements. Also, 6 other components showed robust linkages. In conclusion, computer modeling can reduce the likelihood of accidents and near misses in industrial control rooms by considering the operators' misperception or mental burden and correcting poor design of the panels and inappropriate task allocation.

  16. Proteomic Approach for Diagnostic Applications in Head and Neck Cancer — EDRN Public Portal

    Cancer.gov

    To evaluate the test characteristics of a panel of biomarkers for identifying patients with early stage head and neck squamous cell carcinoma (HNSCC). The primary endpoints are sensitivity, specificity and accuracy of the marker panel. This study of the test characteristics of a modeling strategy for diagnosing HNSCC uses a case-control design, with several types of cases and several types of controls.

  17. 5. Main Control Switchboard (north end rear), view to the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Main Control Switchboard (north end rear), view to the south, with item 14 (the Libby transmission line panel) visible in left foreground, through item 9 (the Hot Springs No. 2 transmission line panel) obliquely visible on left side of the photograph. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  18. Effect of bow-type initial imperfection on reliability of minimum-weight, stiffened structural panels

    NASA Technical Reports Server (NTRS)

    Stroud, W. Jefferson; Krishnamurthy, Thiagaraja; Sykes, Nancy P.; Elishakoff, Isaac

    1993-01-01

    Computations were performed to determine the effect of an overall bow-type imperfection on the reliability of structural panels under combined compression and shear loadings. A panel's reliability is the probability that it will perform the intended function - in this case, carry a given load without buckling or exceeding in-plane strain allowables. For a panel loaded in compression, a small initial bow can cause large bending stresses that reduce both the buckling load and the load at which strain allowables are exceeded; hence, the bow reduces the reliability of the panel. In this report, analytical studies on two stiffened panels quantified that effect. The bow is in the shape of a half-sine wave along the length of the panel. The size e of the bow at panel midlength is taken to be the single random variable. Several probability density distributions for e are examined to determine the sensitivity of the reliability to details of the bow statistics. In addition, the effects of quality control are explored with truncated distributions.

  19. Aircraft interior noise reduction by alternate resonance tuning

    NASA Technical Reports Server (NTRS)

    Gottwald, James A.; Bliss, Donald B.

    1990-01-01

    The focus is on a noise control method which considers aircraft fuselages lined with panels alternately tuned to frequencies above and below the frequency that must be attenuated. An interior noise reduction called alternate resonance tuning (ART) is described both theoretically and experimentally. Problems dealing with tuning single paneled wall structures for optimum noise reduction using the ART methodology are presented, and three theoretical problems are analyzed. The first analysis is a three dimensional, full acoustic solution for tuning a panel wall composed of repeating sections with four different panel tunings within that section, where the panels are modeled as idealized spring-mass-damper systems. The second analysis is a two dimensional, full acoustic solution for a panel geometry influenced by the effect of a propagating external pressure field such as that which might be associated with propeller passage by a fuselage. To reduce the analysis complexity, idealized spring-mass-damper panels are again employed. The final theoretical analysis presents the general four panel problem with real panel sections, where the effect of higher structural modes is discussed. Results from an experimental program highlight real applications of the ART concept and show the effectiveness of the tuning on real structures.

  20. Control of Thermal Deflection, Panel Flutter and Acoustic Fatigue at Elevated Temperatures Using Shape Memory Alloys

    NASA Technical Reports Server (NTRS)

    Mei, Chuh; Huang, Jen-Kuang

    1996-01-01

    The High Speed Civil Transport (HSCT) will have to be designed to withstand high aerodynamic load at supersonic speeds (panel flutter) and high acoustic load (acoustic or sonic fatigue) due to fluctuating boundary layer or jet engine acoustic pressure. The thermal deflection of the skin panels will also alter the vehicle's configuration, thus it may affect the aerodynamic characteristics of the vehicle and lead to poor performance. Shape memory alloys (SMA) have an unique ability to recover large strains completely when the alloy is heated above the characteristic transformation (austenite finish T(sub f)) temperature. The recovery stress and elastic modulus are both temperature dependent, and the recovery stress also depends on the initial strain. An innovative concept is to utilize the recovery stress by embedding the initially strained SMA wire in a graphite/epoxy composite laminated panel. The SMA wires are thus restrained and large inplane forces are induced in the panel at elevated temeperatures. By embedding SMA in composite panel, the panel becomes much stiffer at elevated temperatures. That is because the large tensile inplane forces induced in the panel from the SMA recovery stress. A stiffer panel would certainly yield smaller dynamic responses.

  1. A Randomized, Controlled Trial of a Shared Panel Management Program for Small Practices.

    PubMed

    Bishop, Tara F; Ryan, Andrew M; Chen, Melinda A; Mendelsohn, Jayme; Gottlieb, Daniel; Shih, Sarah; Desai, Priya; Wolff, Elizabeth A; Casalino, Lawrence P

    2016-10-01

    To determine whether a shared panel management program was effective at improving quality of care for patients with uncontrolled chronic disease. Data were extracted from electronic health records. Randomized controlled trial of a panel management program initiated by New York City Department of Health and Mental Hygiene. Patients from 20 practices with an uncontrolled chronic disease and a lapse in care were assigned to the intervention (a phone call requesting that the patient schedule a physician appointment) or usual care. Outcomes were visits to physician practices, body mass index measurement, blood pressure measurement and control, use of antithrombotics, and low-density lipoprotein measurement and control. Panel managers were able to successfully speak with 1,676 patients (14.7 percent of the intervention group). There were no significant differences in outcomes between the intervention and usual care groups. Successfully contacted patients were more likely to have an office visit within 1 year of randomization (45.6 percent [95 percent CI: 22.8, 26.9] vs. 38.1 percent [95 percent CI: 36.8, 39.3]) and more likely to be on antithrombotics (24.4 percent [95 percent CI: 17.7, 31.0]) versus those in the usual care group (17.0 percent [95 percent CI: 13.9, 20.0]) but had no other difference in quality. A shared, low-intensity panel management program run by a city health department did not improve quality of care for patients with chronic illnesses and lapses in care. © Health Research and Educational Trust.

  2. Tilted membrane panel: A new module concept to maximize the impact of air bubbles for membrane fouling control in microalgae harvesting.

    PubMed

    Eliseus, A; Bilad, M R; Nordin, N A H M; Putra, Z A; Wirzal, M D H

    2017-10-01

    Microalgae harvesting using membrane technology is challenging because of its high fouling propensity. As an established fouling mitigation technique, efficacy of air bubbles can be improved by maximizing the impact of shear-rates in scouring foulant. In this study, it is achieved by tilting the membrane panel. We investigate the effect of tilting angle, switching period as well as aeration rate during microalgal broth filtration. Results show that higher tilting angles (up to 20°) improve permeability of up to 2.7 times of the vertical panel. In addition, operating a one-sided panel is better than a two-sided panel, in which the later involved switching mode. One-sided membrane panel only require a half of area, yet its performance is comparable with of a large-scale module. This tilted panel can lead to significant membrane cost reductions and eventually improves the competitiveness of membrane technology for microalgae harvesting application. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Nonlinear vibration and radiation from a panel with transition to chaos induced by acoustic waves

    NASA Technical Reports Server (NTRS)

    Maestrello, Lucio; Frendi, Abdelkader; Brown, Donald E.

    1992-01-01

    The dynamic response of an aircraft panel forced at resonance and off-resonance by plane acoustic waves at normal incidence is investigated experimentally and numerically. Linear, nonlinear (period doubling) and chaotic responses are obtained by increasing the sound pressure level of the excitation. The response time history is sensitive to the input level and to the frequency of excitation. The change in response behavior is due to a change in input conditions, triggered either naturally or by modulation of the bandwidth of the incident waves. Off-resonance, bifurcation is diffused and difficult to maintain, thus the panel response drifts into a linear behavior. The acoustic pressure emanated by the panel is either linear or nonlinear as is the vibration response. The nonlinear effects accumulate during the propagation with distance. Results are also obtained on the control of the panel response using damping tape on aluminum panel and using a graphite epoxy panel having the same size and weight. Good agreement is obtained between the experimental and numerical results.

  4. Nonlinear vibration and radiation from a panel with transition to chaos

    NASA Technical Reports Server (NTRS)

    Maestrello, Lucio; Frendi, Abdelkader; Brown, Donald E.

    1992-01-01

    The dynamic response of an aircraft panel forced at resonance and off-resonance by plane acoustic waves at normal incidence is investigated experimentally and numerically. Linear, nonlinear (period doubling), and chaotic responses are obtained by increasing the sound pressure level of the excitation. The response time history is sensitive to the input level and to the frequency of excitation. The change in response behavior is due to a change in input conditions, triggered either naturally or by modulation of the bandwidth of the incident waves. Off-resonance bifurcation is diffused and difficult to maintain; thus the panel response drifts into a linear behavior. The acoustic pressure emanated by the panel is either linear or nonlinear as is the vibration response. The nonlinear effects accumulate during the propagation with distance. Results are also obtained on the control of the panel response using damping tape on an aluminum panel and a graphite epoxy panel having the same size and weight. Good agreement is obtained betwen the experimental and numerical results.

  5. 141. NITROGEN SUPPLY PANEL PRESSURE REGULATOR IN NORTHWEST CORNER OF ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    141. NITROGEN SUPPLY PANEL PRESSURE REGULATOR IN NORTHWEST CORNER OF CONTROL ROOM (214), LSB (BLDG. 751), FACING WEST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. 75 FR 77645 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Monitoring System (PRAMS), DP11-001 Panel D, Initial Review In accordance with Section 10(a)(2) of the... initial review, discussion, and evaluation of ``Pregnancy Risk Assessment Monitoring System (PRAMS), DP11...

  7. 75 FR 77645 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Pregnancy...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-13

    ... Monitoring System (PRAMS), DP11-001 Panel F, Initial Review In accordance with Section 10(a)(2) of the... initial review, discussion, and evaluation of ``Pregnancy Risk Assessment Monitoring System (PRAMS), DP11...

  8. Command and Control Workshop: Structures and Processes for R&D Service Delivery

    DTIC Science & Technology

    1996-12-01

    syndicates. After getting direction from Deputy Chief of Defence Staff (DCDS) and CRAD as well as a panel of senior officers and managers , the workshop...prepared speeches providing direction to the attendees. This was followed by presentations from a panel of senior officers and civilian managers which...On the morning of the final day, the panel of senior officers and managers reconvened to hear summary presentations of the previous days

  9. Small Satellite Formations for Distributed Surveillance: System Design and Optimal Control Considerations (Formations de petits satellites pour une surveillance distribuee: Considerations relatives la conception de systeme et a l’optimisation de commandes)

    DTIC Science & Technology

    2009-04-01

    System Analysis and Studies Panel • SCI Systems Concepts and Integration Panel • SET Sensors and Electronics Technology Panel These bodies are... Industriales GRUPO M.TORRES Ctra. Pamplona-Huesca, Km.9 31119 Torres de Elorz (Navarra) Spain +34 948 317 811 +34 948 317 952 irene.eguinoa@mtorres.es

  10. Pilot Fullerton sleeps on aft flight deck

    NASA Image and Video Library

    1982-03-30

    STS003-22-113 (24 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, wearing communication kit assembly mini-headset (HDST), sleeps on aft flight deck resting his back against the floor and his feet against commander's ejection seat (S1) back. On-orbit station control panel A8 and payload station panel L15 appear above Fullerton. Special clips for holding notebooks open and beverage containers are velcroed on various panels. Photo credit: NASA

  11. Impact of life expectancy, literacy rate, opened unemployment rate and gross domestic regional income per capita on poverty in the districts/city in Central Sulawesi Province

    NASA Astrophysics Data System (ADS)

    Tombolotutu, A. D.; Djirimu, M. A.; Lutfi, M.; Anggadini, F.

    2018-05-01

    Research was conducted in several districts/city in Central Sulawesi Province in order to determine the effect of life expectancy, literacy rate, opened unemployment rate, and gross domestic regional income per capita on poverty at the districts/city in the province. The analysis used is Panel Data Regression. The results show that first, life expectancy and gross domestic regional income have a negative and significant impact on the poverty level in the districts/city in the Province. Second, the opened unemployment rate has a positive and significant effect on the poverty level in the districts/city in the province. Third, literacy rates show a positive effect and insignificant effect on the poverty level in the districts/city in the Province of Central Sulawesi. Fourth, these four variables simultaneously affect the poverty in the districts/city in Central Sulawesi

  12. Questionnaire design: carry-over effects of overall acceptance question placement and pre-evaluation instructions on overall acceptance scores in central location tests.

    PubMed

    Bastian, Mauresa; Eggett, Dennis L; Jefferies, Laura K

    2015-02-01

    Question placement and usage of pre-evaluation instructions (PEI) in questionnaires for food sensory analysis may bias consumers' scores via carry-over effects. Data from consumer sensory panels previously conducted at a central location, spanning 11 years and covering a broad range of food product categories, were compiled. Overall acceptance (OA) question placement was studied with categories designated as first (the first evaluation question following demographic questions), after nongustation questions (immediately following questions that do not require panelists to taste the product), and later (following all other hedonic and just-about-right [JAR] questions, but occasionally before ranking, open-ended comments, and/or intent to purchase questions). Each panel was categorized as having or not having PEI in the questionnaire; PEI are instructions that appear immediately before the first evaluation question and show panelists all attributes they will evaluate before receiving test samples. Postpanel surveys were administered regarding the self-reported effect of PEI on panelists' evaluation experience. OA scores were analyzed and compared (1) between OA question placement categories and (2) between panels with and without PEI. For most product categories, OA scores tended to be lower when asked later in the questionnaire, suggesting evidence of a carry-over effect. Usage of PEI increased OA scores by 0.10 of a 9-point hedonic scale point, which is not practically significant. Postpanel survey data showed that presence of PEI typically improved the panelists' experience. Using PEI does not appear to introduce a meaningful carry-over effect. © 2015 Institute of Food Technologists®

  13. Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

    NASA Technical Reports Server (NTRS)

    Wu, Shu-Yau; Turner, Travis L.; Rizzi, Stephen A.

    2000-01-01

    At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL was increased. Detailed experimental results will be presented.

  14. Instruction manual, optical effects module electronic controller and processor, model OEMCP

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The OEM-1 electronic module is discussed; it is comprised of four subsystems: the signal processing and display; the stepper motor controls; the chopper controls; and the dc-dc invertor. The OEM-1 module controls the sample wheel so that the relative transmittance of the samples can be compared to the clear aperture position. The 3-1/2 digit digital voltmeter displays the clear aperture signal level as well as the ratio of the remaining sample positions relative to the clear aperture position. The sample wheel position is decoded so that the signals and ratios can be correlated to the data. The OEM is automatically reset to the I sub o on initial turn-on and can be reset to the '0' position by actuating a front panel switch. The sample wheel can be interrupted to change samples or induce a longer integration time if desired by a front panel command. Integration times from 1 - 50 seconds are provided at the front panel, and BCD data for external interfacing is provided.

  15. Molecular detection of viral causes of encephalitis and meningitis in New York State.

    PubMed

    Dupuis, Michelle; Hull, Rene; Wang, Heng; Nattanmai, Seela; Glasheen, Bernadette; Fusco, Heather; Dzigua, Lela; Markey, Katie; Tavakoli, Norma P

    2011-12-01

    The etiology of encephalitis and meningitis, serious diseases of the central nervous system (CNS), in most cases remains unknown. The importance of establishing a diagnosis however, becomes even more important as advances are made in effective therapy. Molecular methods of detection, in particular, PCR, are being used routinely and have established a place in the arsenal of tools for diagnosis of CNS infections. In this study a viral etiological agent was detected by PCR in 340 of the total 2,357 specimens from patients who exhibited symptoms of encephalitis or meningitis. The detection rate increased from 8.9% during the first year of the study to 14.8% during the second year of the study with improved methodology and an expanded panel of viral agents. Methods were enhanced by developing real-time PCR assays (some multiplexed), using increased automation, superior nucleic acid extraction, and reverse transcription (RT) methods, and incorporation of an internal extraction control. Additionally, adenovirus and human herpes virus 6 (HHV-6) were added to the original panel of 10 viruses that included enteroviruses, herpesviruses, and arboviruses. The most common viruses detected were enteroviruses (129; 5.5%), Epstein-Barr virus (EBV) (85; 3.6%), herpes simplex viruses (HSVs) 1 and 2 (67; 2.8%), and varicella zoster virus (VZV) (44; 1.9%). Copyright © 2011 Wiley Periodicals, Inc.

  16. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology

    PubMed Central

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B.; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-01-01

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is <30%. Many different test-methods have been proposed to increase diagnostic accuracy in such lesions, including Galectin-3-ICC (GAL-3-ICC), BRAF mutation analysis (BRAF), Gene Expression Classifier (GEC) alone and GEC+BRAF, mutation/fusion (M/F) panel, alone, M/F panel+miRNA GEC, and M/F panel by next generation sequencing (NGS), FDG-PET/CT, MIBI-Scan and TSHR mRNA blood assay. We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings. In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions. PMID:28472764

  17. Optimization of the level and range of working temperature of the PCM in the gypsum-microencapsulated PCM thermal energy storage unit for summer conditions in Central Poland

    NASA Astrophysics Data System (ADS)

    Łapka, P.; Jaworski, M.

    2017-10-01

    In this paper thermal energy storage (TES) unit in a form of a ceiling panel made of gypsum-microencapsulated PCM composite with internal U-shaped channels was considered and optimal characteristics of the microencapsulated PCM were determined. This panel may be easily incorporated into, e.g., an office or residential ventilation system in order to reduce daily variations of air temperature during the summer without additional costs related to the consumption of energy for preparing air parameters to the desired level. For the purpose of the analysis of heat transfer in the panel, a novel numerical simulator was developed. The numerical model consists of two coupled parts, i.e., the 1D which deals with the air flowing through the U-shaped channel and the 3D which deals with heat transfer in the body of the panel. The computational tool was validated based on the experimental study performed on the special set-up. Using this tool an optimization of parameters of the gypsum-microencapsulated PCM composite was performed in order to determine its most appropriate properties for the application under study. The analyses were performed for averaged local summer conditions in Warsaw, Poland.

  18. The test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

    NASA Technical Reports Server (NTRS)

    Milam, Laura J.

    1990-01-01

    The Cosmic Background Explorer Observatory (COBE) underwent a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

  19. Active control of turbulent boundary layer sound transmission into a vehicle interior

    NASA Astrophysics Data System (ADS)

    Caiazzo, A.; Alujević, N.; Pluymers, B.; Desmet, W.

    2016-09-01

    In high speed automotive, aerospace, and railway transportation, the turbulent boundary layer (TBL) is one of the most important sources of interior noise. The stochastic pressure distribution associated with the turbulence is able to excite significantly structural vibration of vehicle exterior panels. They radiate sound into the vehicle through the interior panels. Therefore, the air flow noise becomes very influential when it comes to the noise vibration and harshness assessment of a vehicle, in particular at low frequencies. Normally, passive solutions, such as sound absorbing materials, are used for reducing the TBL-induced noise transmission into a vehicle interior, which generally improve the structure sound isolation performance. These can achieve excellent isolation performance at higher frequencies, but are unable to deal with the low-frequency interior noise components. In this paper, active control of TBL noise transmission through an acoustically coupled double panel system into a rectangular cavity is examined theoretically. The Corcos model of the TBL pressure distribution is used to model the disturbance. The disturbance is rejected by an active vibration isolation unit reacting between the exterior and the interior panels. Significant reductions of the low-frequency vibrations of the interior panel and the sound pressure in the cavity are observed.

  20. Test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

    NASA Technical Reports Server (NTRS)

    Milam, Laura J.

    1991-01-01

    The Cosmic Background Explorer Observatory (COBE) underwant a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Top