Sample records for central reference point

  1. Electron gun for a multiple beam klystron with magnetic compression of the electron beams

    DOEpatents

    Ives, R. Lawrence; Tran, Hien T; Bui, Thuc; Attarian, Adam; Tallis, William; David, John; Forstall, Virginia; Andujar, Cynthia; Blach, Noah T; Brown, David B; Gadson, Sean E; Kiley, Erin M; Read, Michael

    2013-10-01

    A multi-beam electron gun provides a plurality N of cathode assemblies comprising a cathode, anode, and focus electrode, each cathode assembly having a local cathode axis and also a central cathode point defined by the intersection of the local cathode axis with the emitting surface of the cathode. Each cathode is arranged with its central point positioned in a plane orthogonal to a device central axis, with each cathode central point an equal distance from the device axis and with an included angle of 360/N between each cathode central point. The local axis of each cathode has a cathode divergence angle with respect to the central axis which is set such that the diverging magnetic field from a solenoidal coil is less than 5 degrees with respect to the projection of the local cathode axis onto a cathode reference plane formed by the device axis and the central cathode point, and the local axis of each cathode is also set such that the angle formed between the cathode reference plane and the local cathode axis results in minimum spiraling in the path of the electron beams in a homogenous magnetic field region of the solenoidal field generator.

  2. Dry needling — peripheral and central considerations

    PubMed Central

    Dommerholt, Jan

    2011-01-01

    Dry needling is a common treatment technique in orthopedic manual physical therapy. Although various dry needling approaches exist, the more common and best supported approach targets myofascial trigger points. This article aims to place trigger point dry needling within the context of pain sciences. From a pain science perspective, trigger points are constant sources of peripheral nociceptive input leading to peripheral and central sensitization. Dry needling cannot only reverse some aspects of central sensitization, it reduces local and referred pain, improves range of motion and muscle activation pattern, and alters the chemical environment of trigger points. Trigger point dry needling should be based on a thorough understanding of the scientific background of trigger points, the differences and similarities between active and latent trigger points, motor adaptation, and central sensitize application. Several outcome studies are included, as well as comments on dry needling and acupuncture. PMID:23115475

  3. Referent control and motor equivalence of reaching from standing

    PubMed Central

    Tomita, Yosuke; Feldman, Anatol G.

    2016-01-01

    Motor actions may result from central changes in the referent body configuration, defined as the body posture at which muscles begin to be activated or deactivated. The actual body configuration deviates from the referent configuration, particularly because of body inertia and environmental forces. Within these constraints, the system tends to minimize the difference between these configurations. For pointing movement, this strategy can be expressed as the tendency to minimize the difference between the referent trajectory (RT) and actual trajectory (QT) of the effector (hand). This process may underlie motor equivalent behavior that maintains the pointing trajectory regardless of the number of body segments involved. We tested the hypothesis that the minimization process is used to produce pointing in standing subjects. With eyes closed, 10 subjects reached from a standing position to a remembered target located beyond arm length. In randomly chosen trials, hip flexion was unexpectedly prevented, forcing subjects to take a step during pointing to prevent falling. The task was repeated when subjects were instructed to intentionally take a step during pointing. In most cases, reaching accuracy and trajectory curvature were preserved due to adaptive condition-specific changes in interjoint coordination. Results suggest that referent control and the minimization process associated with it may underlie motor equivalence in pointing. NEW & NOTEWORTHY Motor actions may result from minimization of the deflection of the actual body configuration from the centrally specified referent body configuration, in the limits of neuromuscular and environmental constraints. The minimization process may maintain reaching trajectory and accuracy regardless of the number of body segments involved (motor equivalence), as confirmed in this study of reaching from standing in young healthy individuals. Results suggest that the referent control process may underlie motor equivalence in reaching. PMID:27784802

  4. Fine Guidance Sensing for Coronagraphic Observatories

    NASA Technical Reports Server (NTRS)

    Brugarolas, Paul; Alexander, James W.; Trauger, John T.; Moody, Dwight C.

    2011-01-01

    Three options have been developed for Fine Guidance Sensing (FGS) for coronagraphic observatories using a Fine Guidance Camera within a coronagraphic instrument. Coronagraphic observatories require very fine precision pointing in order to image faint objects at very small distances from a target star. The Fine Guidance Camera measures the direction to the target star. The first option, referred to as Spot, was to collect all of the light reflected from a coronagraph occulter onto a focal plane, producing an Airy-type point spread function (PSF). This would allow almost all of the starlight from the central star to be used for centroiding. The second approach, referred to as Punctured Disk, collects the light that bypasses a central obscuration, producing a PSF with a punctured central disk. The final approach, referred to as Lyot, collects light after passing through the occulter at the Lyot stop. The study includes generation of representative images for each option by the science team, followed by an engineering evaluation of a centroiding or a photometric algorithm for each option. After the alignment of the coronagraph to the fine guidance system, a "nulling" point on the FGS focal point is determined by calibration. This alignment is implemented by a fine alignment mechanism that is part of the fine guidance camera selection mirror. If the star images meet the modeling assumptions, and the star "centroid" can be driven to that nulling point, the contrast for the coronagraph will be maximized.

  5. D Central Line Extraction of Fossil Oyster Shells

    NASA Astrophysics Data System (ADS)

    Djuricic, A.; Puttonen, E.; Harzhauser, M.; Mandic, O.; Székely, B.; Pfeifer, N.

    2016-06-01

    Photogrammetry provides a powerful tool to digitally document protected, inaccessible, and rare fossils. This saves manpower in relation to current documentation practice and makes the fragile specimens more available for paleontological analysis and public education. In this study, high resolution orthophoto (0.5 mm) and digital surface models (1 mm) are used to define fossil boundaries that are then used as an input to automatically extract fossil length information via central lines. In general, central lines are widely used in geosciences as they ease observation, monitoring and evaluation of object dimensions. Here, the 3D central lines are used in a novel paleontological context to study fossilized oyster shells with photogrammetric and LiDAR-obtained 3D point cloud data. 3D central lines of 1121 Crassostrea gryphoides oysters of various shapes and sizes were computed in the study. Central line calculation included: i) Delaunay triangulation between the fossil shell boundary points and formation of the Voronoi diagram; ii) extraction of Voronoi vertices and construction of a connected graph tree from them; iii) reduction of the graph to the longest possible central line via Dijkstra's algorithm; iv) extension of longest central line to the shell boundary and smoothing by an adjustment of cubic spline curve; and v) integration of the central line into the corresponding 3D point cloud. The resulting longest path estimate for the 3D central line is a size parameter that can be applied in oyster shell age determination both in paleontological and biological applications. Our investigation evaluates ability and performance of the central line method to measure shell sizes accurately by comparing automatically extracted central lines with manually collected reference data used in paleontological analysis. Our results show that the automatically obtained central line length overestimated the manually collected reference by 1.5% in the test set, which is deemed sufficient for the selected paleontological application, namely shell age determination.

  6. Robust Vision-Based Pose Estimation Algorithm for AN Uav with Known Gravity Vector

    NASA Astrophysics Data System (ADS)

    Kniaz, V. V.

    2016-06-01

    Accurate estimation of camera external orientation with respect to a known object is one of the central problems in photogrammetry and computer vision. In recent years this problem is gaining an increasing attention in the field of UAV autonomous flight. Such application requires a real-time performance and robustness of the external orientation estimation algorithm. The accuracy of the solution is strongly dependent on the number of reference points visible on the given image. The problem only has an analytical solution if 3 or more reference points are visible. However, in limited visibility conditions it is often needed to perform external orientation with only 2 visible reference points. In such case the solution could be found if the gravity vector direction in the camera coordinate system is known. A number of algorithms for external orientation estimation for the case of 2 known reference points and a gravity vector were developed to date. Most of these algorithms provide analytical solution in the form of polynomial equation that is subject to large errors in the case of complex reference points configurations. This paper is focused on the development of a new computationally effective and robust algorithm for external orientation based on positions of 2 known reference points and a gravity vector. The algorithm implementation for guidance of a Parrot AR.Drone 2.0 micro-UAV is discussed. The experimental evaluation of the algorithm proved its computational efficiency and robustness against errors in reference points positions and complex configurations.

  7. Annotated zoogeography of non-marine Tardigrada. Part I: Central America.

    PubMed

    Kaczmarek, Łukasz; Michalczyk, Łukasz; McInnes, Sandra J

    2014-02-05

    Dividing the world into nine regions, this first paper describes literature records of the limno-terrestrial tardigrades (Tardigrada) reported from Central America. Updating previously published species lists we have revised the taxonomy and provided additional habitat, geographic co-ordinates, and biogeographic comments. It is hoped this work will serve as a reference point and background for further zoogeographic studies.

  8. Imaging performance of annular apertures. IV - Apodization and point spread functions. V - Total and partial energy integral functions

    NASA Technical Reports Server (NTRS)

    Tschunko, H. F. A.

    1983-01-01

    Reference is made to a study by Tschunko (1979) in which it was discussed how apodization modifies the modulation transfer function for various central obstruction ratios. It is shown here how apodization, together with the central obstruction ratio, modifies the point spread function, which is the basic element for the comparison of imaging performance and for the derivation of energy integrals and other functions. At high apodization levels and lower central obstruction (less than 0.1), new extended radial zones are formed in the outer part of the central ring groups. These transmutation of the image functions are of more than theoretical interest, especially if the irradiance levels in the outer ring zones are to be compared to the background irradiance levels. Attention is then given to the energy distribution in point images generated by annular apertures apodized by various transmission functions. The total energy functions are derived; partial energy integrals are determined; and background irradiance functions are discussed.

  9. [How many kids are there with excess weight? What information should be published?

    PubMed

    Pérez-Ríos, Mónica; Santiago-Pérez, María I; Malvar Pintos, Alberto; Suanzes Hernández, Jorge; Hervada Vidal, Xurxo

    2018-06-11

    In epidemiological studies, there is no consensus on which references should be used to characterize the weight status of schoolchildren after estimating their body mass index. The aim of this study is to evaluate the influence that different criteria have on the characterization of the weight status of Galician schoolchildren from 6 to 15 years old and to identify the criterion that best characterizes central obesity. Cross-sectional study on a sample of 7.438 schoolchildren representative by sex and age of the Galician population of 6 to 15 year olds. The prevalence of central obesity and underweight, normal weight, overweight and obesity was estimated using the reference standards of the World Health Organization (WHO), Cole, Orbegozo-2011 and the Enkid study. In order to identify the criterion that best characterizes central obesity, the positive predictive values of obesity and the negative ones of overweight and obesity were calculated. The characterization of schoolchildren according to their weight status was different depending on the reference used with estimates that vary by 20.4 percentage points being prevalence of excess weight using WHO references 41.5% while with Enkid it is 21.1%. The reference with the best predictive capacity of central obesity was those proposed by Cole. The variability observed in the characterization of the weight status of schoolchildren asso- ciated with the use of different reference criteria is very important. If central obesity is a good indicator of excess of weight, the reference proposed by Cole would be the one with the best capacity to characterize the child and youth population, related to the best predictive capacity.

  10. Library Laws of Texas.

    ERIC Educational Resources Information Center

    Seidenberg, Ed, Ed.

    Compiled to provide a central reference point for all legislative information pertaining to libraries in the state of Texas, this publication includes all pertinent legislation as amended through the 66th Legislature, Regular Session, 1979. It contains articles dealing specifically with archives, buildings and property, city libraries, non-profit…

  11. EUPOS - Satellite multifunctional system of reference stations in Central and Eastern Europe

    NASA Astrophysics Data System (ADS)

    Sledzinski, J.

    2003-04-01

    The European project EUPOS (European Position Determination System) of establishment of a system of multifunctional satellite reference stations in Central and Eastern Europe is described in the paper. Fifteen countries intend to participate in the project: Bulgaria, Croatia, Czech Republic, Estonia, Germany, Hungary, Latvia, Lithuania, Macedonia, Poland, Romania, Russia, Serbia, Slovak Republic and Slovenia. One common project will be prepared for all countries, however it will include the existing or developed infrastructure in particular countries. The experiences of establishing and operating of the German network SAPOS as well as experiences gained by other countries will be used. The European network of stations will be compatible with the system SAPOS and future European system Galileo. The network of reference stations will provide signal for both positioning of the geodetic control points and for land, air and marine navigation. Several levels of positioning accuracy will be delivered.

  12. Library Laws of Texas.

    ERIC Educational Resources Information Center

    Getz, Richard E., Comp.

    Compiled to provide a central reference point for all legislative information pertaining to libraries in the State of Texas, this publication includes all pertinent legislation as amended through the 71st Legislature, 1989, Regular Session. This update of the 1980 edition has been expanded to include statutes pertaining to the school and academic…

  13. Analysis of point-to-point lung motion with full inspiration and expiration CT data using non-linear optimization method: optimal geometric assumption model for the effective registration algorithm

    NASA Astrophysics Data System (ADS)

    Kim, Namkug; Seo, Joon Beom; Heo, Jeong Nam; Kang, Suk-Ho

    2007-03-01

    The study was conducted to develop a simple model for more robust lung registration of volumetric CT data, which is essential for various clinical lung analysis applications, including the lung nodule matching in follow up CT studies, semi-quantitative assessment of lung perfusion, and etc. The purpose of this study is to find the most effective reference point and geometric model based on the lung motion analysis from the CT data sets obtained in full inspiration (In.) and expiration (Ex.). Ten pairs of CT data sets in normal subjects obtained in full In. and Ex. were used in this study. Two radiologists were requested to draw 20 points representing the subpleural point of the central axis in each segment. The apex, hilar point, and center of inertia (COI) of each unilateral lung were proposed as the reference point. To evaluate optimal expansion point, non-linear optimization without constraints was employed. The objective function is sum of distances from the line, consist of the corresponding points between In. and Ex. to the optimal point x. By using the nonlinear optimization, the optimal points was evaluated and compared between reference points. The average distance between the optimal point and each line segment revealed that the balloon model was more suitable to explain the lung expansion model. This lung motion analysis based on vector analysis and non-linear optimization shows that balloon model centered on the center of inertia of lung is most effective geometric model to explain lung expansion by breathing.

  14. Variability in alignment of central venous pressure transducer to physiologic reference point in the intensive care unit-A descriptive and correlational study.

    PubMed

    Sjödin, Carl; Sondergaard, Soren; Johansson, Lotta

    2018-06-01

    The phlebostatic axis is the most commonly used anatomical external reference point for central venous pressure measurements. Deviation in the central venous pressure transducer alignment from the phlebostatic axis causes inadequate pressure readings, which may affect treatment decisions for critically ill patients in intensive care units. The primary aim of the study was to assess the variability in central venous pressure transducer levelling in the intensive care unit. We also assessed whether patient characteristics impacted on central venous pressure transducer alignment deviation. A sample of 61 critical care nurses was recruited and asked to place a transducer at the appropriate level for central venous pressure measurement. The measurements were performed in the intensive care unit on critically ill patients in supine and Fowler's positions. The variability among the participants using eyeball levelling and a laser levelling device was calculated in both sessions and adjusted for patient characteristics. A significant variation was found among critical care nurses in the horizontal levelling of the pressure transducer placement when measuring central venous pressure in the intensive care unit. Using a laser levelling device did not reduce the deviation from the phlebostatic axis. Patient characteristics had little impact on the deviation in the measurements. The anatomical external landmark for the phlebostatic axis varied between critical care nurses, as the variation in the central venous pressure transducer placement was not reduced with a laser levelling device. Standardisation of a zero-level for vascular pressures should be considered to reduce the variability in vascular pressure readings in the intensive care unit to improve patient treatment decisions. Further studies are needed to evaluate critical care nurses' knowledge and use of central venous pressure monitoring and whether assistive tools and/or routines can improve the accuracy in vascular pressure measurements in intensive care units. Copyright © 2018 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration

    NASA Astrophysics Data System (ADS)

    Sabet, Mahsheed; Rowshanfarzad, Pejman; Vial, Philip; Menk, Frederick W.; Greer, Peter B.

    2012-08-01

    In this study an amorphous silicon electronic portal imaging device (a-Si EPID) converted to direct detection configuration was investigated as a transit dosimeter for intensity modulated radiation therapy (IMRT). After calibration to dose and correction for a background offset signal, the EPID-measured absolute IMRT transit doses for 29 fields were compared to a MatriXX two-dimensional array of ionization chambers (as reference) using Gamma evaluation (3%, 3 mm). The MatriXX was first evaluated as reference for transit dosimetry. The accuracy of EPID measurements was also investigated by comparison of point dose measurements by an ionization chamber on the central axis with slab and anthropomorphic phantoms in a range of simple to complex fields. The uncertainty in ionization chamber measurements in IMRT fields was also investigated by its displacement from the central axis and comparison with the central axis measurements. Comparison of the absolute doses measured by the EPID and MatriXX with slab phantoms in IMRT fields showed that on average 96.4% and 97.5% of points had a Gamma index<1 in head and neck and prostate fields, respectively. For absolute dose comparisons with anthropomorphic phantoms, the values changed to an average of 93.6%, 93.7% and 94.4% of points with Gamma index<1 in head and neck, brain and prostate fields, respectively. Point doses measured by the EPID and ionization chamber were within 3% difference for all conditions. The deviations introduced in the response of the ionization chamber in IMRT fields were<1%. The direct EPID performance for transit dosimetry showed that it has the potential to perform accurate, efficient and comprehensive in vivo dosimetry for IMRT.

  16. Control system design for the large space systems technology reference platform

    NASA Technical Reports Server (NTRS)

    Edmunds, R. S.

    1982-01-01

    Structural models and classical frequency domain control system designs were developed for the large space systems technology (LSST) reference platform which consists of a central bus structure, solar panels, and platform arms on which a variety of experiments may be mounted. It is shown that operation of multiple independently articulated payloads on a single platform presents major problems when subarc second pointing stability is required. Experiment compatibility will be an important operational consideration for systems of this type.

  17. Contribution of myofascial trigger points to migraine symptoms.

    PubMed

    Giamberardino, Maria Adele; Tafuri, Emmanuele; Savini, Antonella; Fabrizio, Alessandra; Affaitati, Giannapia; Lerza, Rosanna; Di Ianni, Livio; Lapenna, Domenico; Mezzetti, Andrea

    2007-11-01

    This study evaluated the contribution of myofascial trigger points (TrPs) to migraine pain. Seventy-eight migraine patients with cervical active TrPs whose referred areas (RAs) coincided with migraine sites (frontal/temporal) underwent electrical pain threshold measurement in skin, subcutis, and muscle in TrPs and RAs at baseline and after 3, 10, 30, and 60 days; migraine pain assessment (number and intensity of attacks) for 60 days before and 60 days after study start. Fifty-four patients (group 1) underwent TrP anesthetic infiltration on the 3rd, 10th, 30th, and 60th day (after threshold measurement); 24 (group 2) received no treatment. Twenty normal subjects underwent threshold measurements in the same sites and time points as patients. At baseline, all patients showed lower than normal thresholds in TrPs and RAs in all tissues (P < .001). During treatment in group 1, all thresholds increased progressively in TrPs and RAs (P < .0001), with sensory normalization of skin/subcutis in RAs at the end of treatment; migraine pain decreased (P < .001). Threshold increase in RAs and migraine reduction correlated linearly (.0001 < P < .006). In group 2 and normal subjects, no changes occurred. Cervical TrPs with referred areas in migraine sites thus contribute substantially to migraine symptoms, the peripheral nociceptive input from TrPs probably enhancing the sensitization level of central sensory neurons. This article shows the beneficial effects of local therapy of active myofascial trigger points (TrPs) on migraine symptoms in patients in whom migraine sites coincide with the referred areas of the TrPs. These results suggest that migraine pain is often contributed to by myofascial inputs that enhance the level of central neuronal excitability.

  18. Unitary cocycle representations of the Galilean line group: Quantum mechanical principle of equivalence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacGregor, B.R.; McCoy, A.E.; Wickramasekara, S., E-mail: wickrama@grinnell.edu

    2012-09-15

    We present a formalism of Galilean quantum mechanics in non-inertial reference frames and discuss its implications for the equivalence principle. This extension of quantum mechanics rests on the Galilean line group, the semidirect product of the real line and the group of analytic functions from the real line to the Euclidean group in three dimensions. This group provides transformations between all inertial and non-inertial reference frames and contains the Galilei group as a subgroup. We construct a certain class of unitary representations of the Galilean line group and show that these representations determine the structure of quantum mechanics in non-inertialmore » reference frames. Our representations of the Galilean line group contain the usual unitary projective representations of the Galilei group, but have a more intricate cocycle structure. The transformation formula for the Hamiltonian under the Galilean line group shows that in a non-inertial reference frame it acquires a fictitious potential energy term that is proportional to the inertial mass, suggesting the equivalence of inertial mass and gravitational mass in quantum mechanics. - Highlights: Black-Right-Pointing-Pointer A formulation of Galilean quantum mechanics in non-inertial reference frames is given. Black-Right-Pointing-Pointer The key concept is the Galilean line group, an infinite dimensional group. Black-Right-Pointing-Pointer Unitary, cocycle representations of the Galilean line group are constructed. Black-Right-Pointing-Pointer A non-central extension of the group underlies these representations. Black-Right-Pointing-Pointer Quantum equivalence principle and gravity emerge from these representations.« less

  19. Orthodontic intrusion of maxillary incisors: a 3D finite element method study

    PubMed Central

    Saga, Armando Yukio; Maruo, Hiroshi; Argenta, Marco André; Maruo, Ivan Toshio; Tanaka, Orlando Motohiro

    2016-01-01

    Objective: In orthodontic treatment, intrusion movement of maxillary incisors is often necessary. Therefore, the objective of this investigation is to evaluate the initial distribution patterns and magnitude of compressive stress in the periodontal ligament (PDL) in a simulation of orthodontic intrusion of maxillary incisors, considering the points of force application. Methods: Anatomic 3D models reconstructed from cone-beam computed tomography scans were used to simulate maxillary incisors intrusion loading. The points of force application selected were: centered between central incisors brackets (LOAD 1); bilaterally between the brackets of central and lateral incisors (LOAD 2); bilaterally distal to the brackets of lateral incisors (LOAD 3); bilaterally 7 mm distal to the center of brackets of lateral incisors (LOAD 4). Results and Conclusions: Stress concentrated at the PDL apex region, irrespective of the point of orthodontic force application. The four load models showed distinct contour plots and compressive stress values over the midsagittal reference line. The contour plots of central and lateral incisors were not similar in the same load model. LOAD 3 resulted in more balanced compressive stress distribution. PMID:27007765

  20. Creating Space for Infants to Influence ECEC Practice: The Encounter, Écart, Reversibility and Ethical Reflection

    ERIC Educational Resources Information Center

    Elwick, Sheena; Bradley, Ben; Sumsion, Jennifer

    2014-01-01

    The idea that infant participation in research is achievable by researchers "voicing" infants' experiences and "perspectives" is a central feature of current moves towards participatory research. In this article we offer an alternative. Specifically, we suggest a different point of reference than infants' own…

  1. Deriving Silence through Dependent Reference: Focus on Pronouns

    ERIC Educational Resources Information Center

    Livitz, Inna G.

    2014-01-01

    The starting point of this dissertation is the observation that pronouns that are obligatorily dependent on a sufficiently local antecedent are persistently silent. The classical hypothesis has been that silence is a lexical property of such elements. The central claim of this dissertation is that silence is instead a product of syntax--of the way…

  2. Budget. School Business Management Handbook No. 3. Revised.

    ERIC Educational Resources Information Center

    Debus, Richard C.

    The material in this handbook has been designed for continuous reference and use by administrators and school board members in formulating sound school budgets. Statements of practices and policy express the general situation and simply provide a starting point. Practical applications in union free, central, and city school districts in cities of…

  3. Rambling and trembling in response to body loading.

    PubMed

    Tahayor, Behdad; Riley, Zachary A; Mahmoudian, Armaghan; Koceja, David M; Hong, Siang Lee

    2012-04-01

    Various studies have suggested that postural sway is controlled by at least two subsystems. Rambling-Trembling analysis is a widely accepted methodology to dissociate the signals generated by these two hypothetical subsystems. The core assumption of this method is based on the equilibrium point hypothesis which suggests that the central nervous system preserves upright standing by transiently shifting the center of pressure (COP) from one equilibrium point to another. The trajectory generated by this shifting is referred to as rambling and its difference from the original COP signal is referred to as trembling. In this study we showed that these two components of COP are differentially affected when standing with external loads. Using Detrended Fluctuation analysis, we compared the pattern of these two signals in different configurations of body loading. Our findings suggest that by applying an external load, the dynamics of the trembling component is altered independently of the area of postural sway and also independently of the rambling component. The dynamics of rambling changed only during the backloading condition in which the postural sway area also substantially increased. It can be suggested that during loaded standing, the trembling mechanism (which is suggested to be activated by peripheral mechanisms and reflexes) is altered without affecting the central influence on the shifts of the equilibrium point.

  4. Wave optics of the central spot in planetary occultations

    NASA Technical Reports Server (NTRS)

    Hubbard, W. B.

    1977-01-01

    The detection of a bright central spot during the occultation of epsilon Geminorum by Mars demonstrates that an exponentially-stratified planetary atmosphere can act as a lens providing very high resolution of distant objects (e.g., quasars, white dwarfs, and pulsars). The diffraction nature of the central occultation spot is investigated, with special reference to Mars and Venus. In practice, however, central occultations by these planets are seldom observable from the earth's surface, and spacecraft would have to be used to obtain a suitable orientation for observers. Further difficulties may be encountered in image deconvolution needed for extended objects, in location of the image of a true point source, and in compensation for peculiarities of planets and their atmospheres.

  5. Beginning Plant Biotechnology Laboratories Using Fast Plants.

    ERIC Educational Resources Information Center

    Williams, Mike

    This set of 16 laboratory activities is designed to illustrate the life cycle of Brassicae plants from seeds in pots to pods in 40 days. At certain points along the production cycle of the central core of labs, there are related lateral labs to provide additional learning opportunities employing this family of plants, referred to as "fast…

  6. [Centralization of health services in primary care in summer: Patients and professionals view during two consecutive years].

    PubMed

    Giménez, N; Martínez, J M; Clanchet, T

    2015-01-01

    The Spanish primary health care, gateway and pillar of the Health Care System has his resources increasingly constrained by current crisis. To know the opinion of users and professionals on two primary care centers which centralized in August 2011 and 2012 the attendance of seven primary care centers. Two questionnaires were designed: a telephone survey of a random sample of users and a self-completed questionnaire for health care professionals. The variables were scored on a scale of 1-10 (low to high). Cronbach's coefficient α>0,84. 1293 people responded (836 users and 357 professionals). Users rated, in 2011, the satisfaction with 6.7 points in August and 7.3 points the rest of the year (P<.001). And, in 2012, with 7.7 points in August and 8.1 points the rest of the year (P<.001). Health care professionals, rated their satisfaction with 6.8 points in 2011 and 7.3 points in 2012. The waiting time was the only variable best scores in August that the rest of the year. The perception of the solution given in consultation did not change. Satisfaction, marking, care and treatment were highest rated in the regular center than in the reference center (P<.001). The centralization of primary health care during periods of reduced demand could reduce costs while maintaining quality. The experience of centralizing primary care services during August was perceived as acceptable and improved over time. Users showed a slight, but significant, preference for their usual primary care center. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Exploring behavior of an unusual megaherbivore: A spatially explicit foraging model of the hippopotamus

    USGS Publications Warehouse

    Lewison, R.L.; Carter, J.

    2004-01-01

    Herbivore foraging theories have been developed for and tested on herbivores across a range of sizes. Due to logistical constraints, however, little research has focused on foraging behavior of megaherbivores. Here we present a research approach that explores megaherbivore foraging behavior, and assesses the applicability of foraging theories developed on smaller herbivores to megafauna. With simulation models as reference points for the analysis of empirical data, we investigate foraging strategies of the common hippopotamus (Hippopotamus amphibius). Using a spatially explicit individual based foraging model, we apply traditional herbivore foraging strategies to a model hippopotamus, compare model output, and then relate these results to field data from wild hippopotami. Hippopotami appear to employ foraging strategies that respond to vegetation characteristics, such as vegetation quality, as well as spatial reference information, namely distance to a water source. Model predictions, field observations, and comparisons of the two support that hippopotami generally conform to the central place foraging construct. These analyses point to the applicability of general herbivore foraging concepts to megaherbivores, but also point to important differences between hippopotami and other herbivores. Our synergistic approach of models as reference points for empirical data highlights a useful method of behavioral analysis for hard-to-study megafauna. ?? 2003 Elsevier B.V. All rights reserved.

  8. Motion in a Central Field in the Presence of a Constant Perturbing Acceleration in a Coordinate System Comoving with the Velocity Vector

    NASA Astrophysics Data System (ADS)

    Batmunkh, N.; Sannikova, T. N.; Kholshevnikov, K. V.

    2018-04-01

    The motion of a zero-mass point under the action of gravitation toward a central body and a perturbing acceleration P is considered. The magnitude of P is taken to be small compared to the main acceleration due to the gravitation of the central body, and the components of the vector P are taken to be constant in a reference frame with its origin at the central body and its axes directed along the velocity vector, normal to the velocity vector in the plane of the osculating orbit, and along the binormal. The equations in the mean elements were obtained in an earlier study. The algorithm used to solve these equations is given in this study. This algorithm is analogous to one constructed earlier for the case when P is constant in a reference frame tied to the radius vector. The properties of the solutions are similar. The main difference is that, in the most important cases, the quadratures to which the solution reduces lead to non-elementary functions. However, they can be expressed as series in powers of the eccentricity e that converge for e < 1, and often also for e = 1.

  9. Hypervelocity Inflight Trajectory Scatter (HITS) Code. User’s Manual

    DTIC Science & Technology

    1976-04-01

    referred to as skewness. The fourth central moment is referred to as kurtosis and provides an additional measure of the clustering of the distribution... clustering of data points in the resulting "scatter diagram" would indicate correlation. The correlation can be quantified by fit- ting a straight line...10- *4 U* 0%.0 Coo IX wV~ Z de *I *- 0 On Wa )I GMX Ŕ.~ Ot. *P0 WX #- % OW- W 00WIj u +,- >ot o-O- oW cbok~ o*9 lWI $ Wld6 0000000N000 0 4 00 6 6

  10. Functional Magnetic Resonance Imaging Study of Piaget's Conservation-of-Number Task in Preschool and School-Age Children: A Neo-Piagetian Approach

    ERIC Educational Resources Information Center

    Houde, Olivier; Pineau, Arlette; Leroux, Gaelle; Poirel, Nicolas; Perchey, Guy; Lanoe, Celine; Lubin, Amelie; Turbelin, Marie-Renee; Rossi, Sandrine; Simon, Gregory; Delcroix, Nicolas; Lamberton, Franck; Vigneau, Mathieu; Wisniewski, Gabriel; Vicet, Jean-Rene; Mazoyer, Bernard

    2011-01-01

    Jean Piaget's theory is a central reference point in the study of logico-mathematical development in children. One of the most famous Piagetian tasks is number conservation. Failures and successes in this task reveal two fundamental stages in children's thinking and judgment, shifting at approximately 7 years of age from visuospatial intuition to…

  11. Metallic quantum critical points with finite BCS couplings

    NASA Astrophysics Data System (ADS)

    Raghu, Srinivas

    The problem of superconductivity near quantum critical points (QCPs) remains a central topic of modern condensed matter physics. In such systems, there is a competition between the enhanced pairing tendency due to the presence of long-range attractive interactions near criticality, and the suppression of superconductivity due to the destruction of Landau quasiparticles. I will describe some recent work that addresses these competing effects in the context of a solvable model of a metallic quantum critical point. I will show that the two effects - namely the enhanced pairing and the destruction of Landau quasiparticles - can offset one another, resulting in stable ''naked'' quantum critical points without superconductivity. However, the resulting quantum critical metal exhibits strong superconducting fluctuations on all length scales. Reference: S.R., Gonzalo Torroba, and Huajia Wang, arXiv1507.06652, PRB(2015).

  12. Variability of 137Cs inventory at a reference site in west-central Iran.

    PubMed

    Bazshoushtari, Nasim; Ayoubi, Shamsollah; Abdi, Mohammad Reza; Mohammadi, Mohammad

    2016-12-01

    137 Cs technique has been widely used for the evaluation rates and patterns of soil erosion and deposition. This technique requires an accurate estimate of the values of 137 Cs inventory at the reference site. This study was conducted to evaluate the variability of the inventory of 137 Cs regarding to the sampling program including sample size, distance and sampling method at a reference site located in vicinity of Fereydan district in Isfahan province, west-central Iran. Two 3 × 8 grids were established comprising large grid (35 m length and 8 m width), and small grid (24 m length and 6 m width). At each grid intersection two soil samples were collected from 0 to 15 cm and 15-30 cm depths, totally 96 soil samples from 48 sampling points. Coefficients of variation for 137 Cs inventory in the soil samples was relatively low (CV = 15%), and the sampling distance and methods used did not significantly affect the 137 Cs inventories across the studied reference site. To obtain a satisfactory estimate of the mean 137 Cs activity in the reference sites, particularly those located in the semiarid regions, it is recommended to collect at least four samples along in a grid pattern 3 m apart. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. On the Reporting of Experimental and Control Therapies in Stroke Rehabilitation Trials: A Systematic Review.

    PubMed

    Lohse, Keith R; Pathania, Anupriya; Wegman, Rebecca; Boyd, Lara A; Lang, Catherine E

    2018-03-01

    To use the Centralized Open-Access Rehabilitation database for Stroke to explore reporting of both experimental and control interventions in randomized controlled trials for stroke rehabilitation (including upper and lower extremity therapies). The Centralized Open-Access Rehabilitation database for Stroke was created from a search of MEDLINE, Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Cumulative Index of Nursing and Allied Health from the earliest available date to May 31, 2014. A total of 2892 titles were reduced to 514 that were screened by full text. This screening left 215 randomized controlled trials in the database (489 independent groups representing 12,847 patients). Using a mixture of qualitative and quantitative methods, we performed a text-based analysis of how the procedures of experimental and control therapies were described. Experimental and control groups were rated by 2 independent coders according to the Template for Intervention Description and Replication criteria. Linear mixed-effects regression with a random effect of study (groups nested within studies) showed that experimental groups had statistically more words in their procedures (mean, 271.8 words) than did control groups (mean, 154.8 words) (P<.001). Experimental groups had statistically more references in their procedures (mean, 1.60 references) than did control groups (mean, .82 references) (P<.001). Experimental groups also scored significantly higher on the total Template for Intervention Description and Replication checklist (mean score, 7.43 points) than did control groups (mean score, 5.23 points) (P<.001). Control treatments in stroke motor rehabilitation trials are underdescribed relative to experimental treatments. These poor descriptions are especially problematic for "conventional" therapy control groups. Poor reporting is a threat to the internal validity and generalizability of clinical trial results. We recommend authors use preregistered protocols and established reporting criteria to improve transparency. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Mapping experiment with space station

    NASA Technical Reports Server (NTRS)

    Wu, S. S. C.

    1986-01-01

    Mapping of the Earth from space stations can be approached in two areas. One is to collect gravity data for defining topographic datum using Earth's gravity field in terms of spherical harmonics. The other is to search and explore techniques of mapping topography using either optical or radar images with or without reference to ground central points. Without ground control points, an integrated camera system can be designed. With ground control points, the position of the space station (camera station) can be precisely determined at any instant. Therefore, terrestrial topography can be precisely mapped either by conventional photogrammetric methods or by current digital technology of image correlation. For the mapping experiment, it is proposed to establish four ground points either in North America or Africa (including the Sahara desert). If this experiment should be successfully accomplished, it may also be applied to the defense charting systems.

  15. A study of the mechanism of thigmomorphogenesis in plants, with special reference to the role of ethylene and its significance to research with plants in space

    NASA Technical Reports Server (NTRS)

    Jaffe, M. J.

    1979-01-01

    Because of the paucity of data concerning thigmomorphogenesis, all aspects of the phenomenon were under study, although the role of ethylene mediation was central to the approach. Although this report must necessarily point to a specific time in ongoing research, several aspects of the study reached at least temporary stopping points and were therefore written and submitted for publication. These are identified. Other papers which are currently in preparation, but not yet submitted, are also identified. The phenomenon of thigmomorphogenesis is divided into the sensory function, transduction step(s) and the response function.

  16. Enterprise Reference Library

    NASA Technical Reports Server (NTRS)

    Bickham, Grandin; Saile, Lynn; Havelka, Jacque; Fitts, Mary

    2011-01-01

    Introduction: Johnson Space Center (JSC) offers two extensive libraries that contain journals, research literature and electronic resources. Searching capabilities are available to those individuals residing onsite or through a librarian s search. Many individuals have rich collections of references, but no mechanisms to share reference libraries across researchers, projects, or directorates exist. Likewise, information regarding which references are provided to which individuals is not available, resulting in duplicate requests, redundant labor costs and associated copying fees. In addition, this tends to limit collaboration between colleagues and promotes the establishment of individual, unshared silos of information The Integrated Medical Model (IMM) team has utilized a centralized reference management tool during the development, test, and operational phases of this project. The Enterprise Reference Library project expands the capabilities developed for IMM to address the above issues and enhance collaboration across JSC. Method: After significant market analysis for a multi-user reference management tool, no available commercial tool was found to meet this need, so a software program was built around a commercial tool, Reference Manager 12 by The Thomson Corporation. A use case approach guided the requirements development phase. The premise of the design is that individuals use their own reference management software and export to SharePoint when their library is incorporated into the Enterprise Reference Library. This results in a searchable user-specific library application. An accompanying share folder will warehouse the electronic full-text articles, which allows the global user community to access full -text articles. Discussion: An enterprise reference library solution can provide a multidisciplinary collection of full text articles. This approach improves efficiency in obtaining and storing reference material while greatly reducing labor, purchasing and duplication costs. Most importantly, increasing collaboration across research groups provides unprecedented access to information relevant to NASA s mission. Conclusion: This project is an expansion and cost-effective leveraging of the existing JSC centralized library. Adding key word and author search capabilities and an alert function for notifications about new articles, based on users profiles, represent examples of future enhancements.

  17. Internal validation of the DNAscan/ANDE™ Rapid DNA Analysis™ platform and its associated PowerPlex® 16 high content DNA biochip cassette for use as an expert system with reference buccal swabs.

    PubMed

    Moreno, Lilliana I; Brown, Alice L; Callaghan, Thomas F

    2017-07-01

    Rapid DNA platforms are fully integrated systems capable of producing and analyzing short tandem repeat (STR) profiles from reference sample buccal swabs in less than two hours. The technology requires minimal user interaction and experience making it possible for high quality profiles to be generated outside an accredited laboratory. The automated production of point of collection reference STR profiles could eliminate the time delay for shipment and analysis of arrestee samples at centralized laboratories. Furthermore, point of collection analysis would allow searching against profiles from unsolved crimes during the normal booking process once the infrastructure to immediately search the Combined DNA Index System (CODIS) database from the booking station is established. The DNAscan/ANDE™ Rapid DNA Analysis™ System developed by Network Biosystems was evaluated for robustness and reliability in the production of high quality reference STR profiles for database enrollment and searching applications. A total of 193 reference samples were assessed for concordance of the CODIS 13 loci. Studies to evaluate contamination, reproducibility, precision, stutter, peak height ratio, noise and sensitivity were also performed. The system proved to be robust, consistent and dependable. Results indicated an overall success rate of 75% for the 13 CODIS core loci and more importantly no incorrect calls were identified. The DNAscan/ANDE™ could be confidently used without human interaction in both laboratory and non-laboratory settings to generate reference profiles. Published by Elsevier B.V.

  18. Keep an eye on your hands: on the role of visual mechanisms in processing of haptic space

    PubMed Central

    Zuidhoek, Sander; Noordzij, Matthijs L.; Kappers, Astrid M. L.

    2008-01-01

    The present paper reviews research on a haptic orientation processing. Central is a task in which a test bar has to be set parallel to a reference bar at another location. Introducing a delay between inspecting the reference bar and setting the test bar leads to a surprising improvement. Moreover, offering visual background information also elevates performance. Interestingly, (congenitally) blind individuals do not or to a weaker extent show the improvement with time, while in parallel to this, they appear to benefit less from spatial imagery processing. Together this strongly points to an important role for visual processing mechanisms in the perception of haptic inputs. PMID:18196305

  19. HTR-PROTEUS pebble bed experimental program cores 9 & 10: columnar hexagonal point-on-point packing with a 1:1 moderator-to-fuel pebble ratio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bess, John D.

    2014-03-01

    PROTEUS is a zero-power research reactor based on a cylindrical graphite annulus with a central cylindrical cavity. The graphite annulus remains basically the same for all experimental programs, but the contents of the central cavity are changed according to the type of reactor being investigated. Through most of its service history, PROTEUS has represented light-water reactors, but from 1992 to 1996 PROTEUS was configured as a pebble-bed reactor (PBR) critical facility and designated as HTR-PROTEUS. The nomenclature was used to indicate that this series consisted of High Temperature Reactor experiments performed in the PROTEUS assembly. During this period, seventeen criticalmore » configurations were assembled and various reactor physics experiments were conducted. These experiments included measurements of criticality, differential and integral control rod and safety rod worths, kinetics, reaction rates, water ingress effects, and small sample reactivity effects (Ref. 3). HTR-PROTEUS was constructed, and the experimental program was conducted, for the purpose of providing experimental benchmark data for assessment of reactor physics computer codes. Considerable effort was devoted to benchmark calculations as a part of the HTR-PROTEUS program. References 1 and 2 provide detailed data for use in constructing models for codes to be assessed. Reference 3 is a comprehensive summary of the HTR-PROTEUS experiments and the associated benchmark program. This document draws freely from these references. Only Cores 9 and 10 are evaluated in this benchmark report due to similarities in their construction. The other core configurations of the HTR-PROTEUS program are evaluated in their respective reports as outlined in Section 1.0. Cores 9 and 10 were evaluated and determined to be acceptable benchmark experiments.« less

  20. HTR-PROTEUS PEBBLE BED EXPERIMENTAL PROGRAM CORES 5, 6, 7, & 8: COLUMNAR HEXAGONAL POINT-ON-POINT PACKING WITH A 1:2 MODERATOR-TO-FUEL PEBBLE RATIO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John D. Bess

    2013-03-01

    PROTEUS is a zero-power research reactor based on a cylindrical graphite annulus with a central cylindrical cavity. The graphite annulus remains basically the same for all experimental programs, but the contents of the central cavity are changed according to the type of reactor being investigated. Through most of its service history, PROTEUS has represented light-water reactors, but from 1992 to 1996 PROTEUS was configured as a pebble-bed reactor (PBR) critical facility and designated as HTR-PROTEUS. The nomenclature was used to indicate that this series consisted of High Temperature Reactor experiments performed in the PROTEUS assembly. During this period, seventeen criticalmore » configurations were assembled and various reactor physics experiments were conducted. These experiments included measurements of criticality, differential and integral control rod and safety rod worths, kinetics, reaction rates, water ingress effects, and small sample reactivity effects (Ref. 3). HTR-PROTEUS was constructed, and the experimental program was conducted, for the purpose of providing experimental benchmark data for assessment of reactor physics computer codes. Considerable effort was devoted to benchmark calculations as a part of the HTR-PROTEUS program. References 1 and 2 provide detailed data for use in constructing models for codes to be assessed. Reference 3 is a comprehensive summary of the HTR-PROTEUS experiments and the associated benchmark program. This document draws freely from these references. Only Cores 9 and 10 are evaluated in this benchmark report due to similarities in their construction. The other core configurations of the HTR-PROTEUS program are evaluated in their respective reports as outlined in Section 1.0. Cores 9 and 10 were evaluated and determined to be acceptable benchmark experiments.« less

  1. HTR-PROTEUS PEBBLE BED EXPERIMENTAL PROGRAM CORES 9 & 10: COLUMNAR HEXAGONAL POINT-ON-POINT PACKING WITH A 1:1 MODERATOR-TO-FUEL PEBBLE RATIO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John D. Bess

    2013-03-01

    PROTEUS is a zero-power research reactor based on a cylindrical graphite annulus with a central cylindrical cavity. The graphite annulus remains basically the same for all experimental programs, but the contents of the central cavity are changed according to the type of reactor being investigated. Through most of its service history, PROTEUS has represented light-water reactors, but from 1992 to 1996 PROTEUS was configured as a pebble-bed reactor (PBR) critical facility and designated as HTR-PROTEUS. The nomenclature was used to indicate that this series consisted of High Temperature Reactor experiments performed in the PROTEUS assembly. During this period, seventeen criticalmore » configurations were assembled and various reactor physics experiments were conducted. These experiments included measurements of criticality, differential and integral control rod and safety rod worths, kinetics, reaction rates, water ingress effects, and small sample reactivity effects (Ref. 3). HTR-PROTEUS was constructed, and the experimental program was conducted, for the purpose of providing experimental benchmark data for assessment of reactor physics computer codes. Considerable effort was devoted to benchmark calculations as a part of the HTR-PROTEUS program. References 1 and 2 provide detailed data for use in constructing models for codes to be assessed. Reference 3 is a comprehensive summary of the HTR-PROTEUS experiments and the associated benchmark program. This document draws freely from these references. Only Cores 9 and 10 are evaluated in this benchmark report due to similarities in their construction. The other core configurations of the HTR-PROTEUS program are evaluated in their respective reports as outlined in Section 1.0. Cores 9 and 10 were evaluated and determined to be acceptable benchmark experiments.« less

  2. Myofascial trigger points: spontaneous electrical activity and its consequences for pain induction and propagation

    PubMed Central

    2011-01-01

    Active myofascial trigger points are one of the major peripheral pain generators for regional and generalized musculoskeletal pain conditions. Myofascial trigger points are also the targets for acupuncture and/or dry needling therapies. Recent evidence in the understanding of the pathophysiology of myofascial trigger points supports The Integrated Hypothesis for the trigger point formation; however unanswered questions remain. Current evidence shows that spontaneous electrical activity at myofascial trigger point originates from the extrafusal motor endplate. The spontaneous electrical activity represents focal muscle fiber contraction and/or muscle cramp potentials depending on trigger point sensitivity. Local pain and tenderness at myofascial trigger points are largely due to nociceptor sensitization with a lesser contribution from non-nociceptor sensitization. Nociceptor and non-nociceptor sensitization at myofascial trigger points may be part of the process of muscle ischemia associated with sustained focal muscle contraction and/or muscle cramps. Referred pain is dependent on the sensitivity of myofascial trigger points. Active myofascial trigger points may play an important role in the transition from localized pain to generalized pain conditions via the enhanced central sensitization, decreased descending inhibition and dysfunctional motor control strategy. PMID:21439050

  3. Pre-analytical and analytical aspects affecting clinical reliability of plasma glucose results.

    PubMed

    Pasqualetti, Sara; Braga, Federica; Panteghini, Mauro

    2017-07-01

    The measurement of plasma glucose (PG) plays a central role in recognizing disturbances in carbohydrate metabolism, with established decision limits that are globally accepted. This requires that PG results are reliable and unequivocally valid no matter where they are obtained. To control the pre-analytical variability of PG and prevent in vitro glycolysis, the use of citrate as rapidly effective glycolysis inhibitor has been proposed. However, the commercial availability of several tubes with studies showing different performance has created confusion among users. Moreover, and more importantly, studies have shown that tubes promptly inhibiting glycolysis give PG results that are significantly higher than tubes containing sodium fluoride only, used in the majority of studies generating the current PG cut-points, with a different clinical classification of subjects. From the analytical point of view, to be equivalent among different measuring systems, PG results should be traceable to a recognized higher-order reference via the implementation of an unbroken metrological hierarchy. In doing this, it is important that manufacturers of measuring systems consider the uncertainty accumulated through the different steps of the selected traceability chain. In particular, PG results should fulfil analytical performance specifications defined to fit the intended clinical application. Since PG has tight homeostatic control, its biological variability may be used to define these limits. Alternatively, given the central diagnostic role of the analyte, an outcome model showing the impact of analytical performance of test on clinical classifications of subjects can be used. Using these specifications, performance assessment studies employing commutable control materials with values assigned by reference procedure have shown that the quality of PG measurements is often far from desirable and that problems are exacerbated using point-of-care devices. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Tunnel Point Cloud Filtering Method Based on Elliptic Cylindrical Model

    NASA Astrophysics Data System (ADS)

    Zhua, Ningning; Jiaa, Yonghong; Luo, Lun

    2016-06-01

    The large number of bolts and screws that attached to the subway shield ring plates, along with the great amount of accessories of metal stents and electrical equipments mounted on the tunnel walls, make the laser point cloud data include lots of non-tunnel section points (hereinafter referred to as non-points), therefore affecting the accuracy for modeling and deformation monitoring. This paper proposed a filtering method for the point cloud based on the elliptic cylindrical model. The original laser point cloud data was firstly projected onto a horizontal plane, and a searching algorithm was given to extract the edging points of both sides, which were used further to fit the tunnel central axis. Along the axis the point cloud was segmented regionally, and then fitted as smooth elliptic cylindrical surface by means of iteration. This processing enabled the automatic filtering of those inner wall non-points. Experiments of two groups showed coincident results, that the elliptic cylindrical model based method could effectively filter out the non-points, and meet the accuracy requirements for subway deformation monitoring. The method provides a new mode for the periodic monitoring of tunnel sections all-around deformation in subways routine operation and maintenance.

  5. Protocol and standard operating procedures for common use in a worldwide multicenter study on reference values.

    PubMed

    Ozarda, Yesim; Ichihara, Kiyoshi; Barth, Julian H; Klee, George

    2013-05-01

    The reference intervals (RIs) given in laboratory reports have an important role in aiding clinicians in interpreting test results in reference to values of healthy populations. In this report, we present a proposed protocol and standard operating procedures (SOPs) for common use in conducting multicenter RI studies on a national or international scale. The protocols and consensus on their contents were refined through discussions in recent C-RIDL meetings. The protocol describes in detail (1) the scheme and organization of the study, (2) the target population, inclusion/exclusion criteria, ethnicity, and sample size, (3) health status questionnaire, (4) target analytes, (5) blood collection, (6) sample processing and storage, (7) assays, (8) cross-check testing, (9) ethics, (10) data analyses, and (11) reporting of results. In addition, the protocol proposes the common measurement of a panel of sera when no standard materials exist for harmonization of test results. It also describes the requirements of the central laboratory, including the method of cross-check testing between the central laboratory of each country and local laboratories. This protocol and the SOPs remain largely exploratory and may require a reevaluation from the practical point of view after their implementation in the ongoing worldwide study. The paper is mainly intended to be a basis for discussion in the scientific community.

  6. Central Asian mountain Rhithrogenini (Ephemeroptera: Heptageniidae) with pointed and ephemeropteroid claws in the winged stages.

    PubMed

    Kluge, Nikita J

    2015-08-03

    Among mountain species of Heptageniidae from Central Asia, six species belonging to the taxa Cinygmula McDunnough 1933, Himalogena Kluge 2004 and Caucasiron Kluge 1997 have all claws of the winged stages (subimago and imago) pointed. In this area Cinygmula is represented by two species: C. hutchinsoni (Traver 1939) (with pointed claws) and C. joosti Braasch 1977 (with the more typical ephemeropteroid claws); for both species all stages of both sexes associated by rearing are redescribed. The Central Asian mountain taxon Himalogena includes seven species: Rhithrogena (Himalogena) tianshanica Brodsky 1930, Rh. (H.) pamirica sp. n., Rh. (H.) carnivora sp. n., Rh. (H.) semicarnivora sp. n., Rh. (H.) stackelbergi Sinitshenkova 1973, Rh. (H.) gunti sp. n. and Rh. (H.) nepalensis Braasch 1984; for five of them, all stages of both sexes associated by rearing are redescribed; Rh. (H.) semicarnivora is known as male imagoes reared from larvae; Rh. (H.) nepalensis formerly known only as larvae, is redescribed based on an anomalous female imago (with gynandromorphism caused by helminth in abdomen) reared from the larval stage. Among these species, Rh. (H.) tianshanica, Rh. (H.) pamirica, Rh. (H.) carnivora and Rh. (H.) semicarnivora have mandibles and the labrum modified for carnivorism, while the other three species have the usual Rhithrogena mouth apparatus. Imagoes and subimagoes of Rh. (H.) pamirica, Rh. (H.) carnivora, Rh. (H.) gunti and Rh. (H.) nepalensis, have both claws of each leg pointed, while the other species have ephemeropteroid claws. Corrections to the description of Rh. minima Sinitshenkova 1973 claw denticulation and to original figure references are given. The taxon Ironopsis/g1 is represented by two species in the Central Asian mountains: Epeorus (Caucasiron) guttatus (Braasch & Soldán 1979) (with pointed claws) and Epeorus (Ironopsis) rheophilus (Brodsky 1930) (with ephemeropteroid claws); for both species all stages of both sexes associated by rearing are redescribed. The character distribution patterns of pointed and ephemeropteroid claws within mayfly phylogeny leads one to assume that both types of claws repeatedly change back and forth within Ephemeroptera. However, within Heptageniidae, those species whose winged stages have pointed claws have overlapping ranges of distribution limited to high mountain systems of Central Asia; their larvae inhabit the same biotopes (stones in rapid streams), have the same habitat and can come into contact with one another when they aggregate on a stone. These observations allow for a hypothesis that explains the repeated change to pointed claws from ephemeropteroid claws among various Heptageniidae species via horizontal transfer of some hereditary factor during the evolutionary history of each of those species with the peculiar claw morphology.

  7. Study of a new central compact object: The neutron star in the supernova remnant G15.9+0.2

    NASA Astrophysics Data System (ADS)

    Klochkov, D.; Suleimanov, V.; Sasaki, M.; Santangelo, A.

    2016-08-01

    We present our study of the central point source CXOU J181852.0-150213 in the young Galactic supernova remnant (SNR) G15.9+0.2 based on the recent ~90 ks Chandra observations. The point source was discovered in 2005 in shorter Chandra observations and was hypothesized to be a neutron star associated with the SNR. Our X-ray spectral analysis strongly supports the hypothesis of a thermally emitting neutron star associated with G15.9+0.2. We conclude that the object belongs to the class of young cooling low-magnetized neutron stars referred to as central compact objects (CCOs). We modeled the spectrum of the neutron star with a blackbody spectral function and with our hydrogen and carbon neutron star atmosphere models, assuming that the radiation is uniformly emitted by the entire stellar surface. Under this assumption, only the carbon atmosphere models yield a distance that is compatible with a source located in the Galaxy. In this respect, CXOU J181852.0-150213 is similar to two other well-studied CCOs, the neutron stars in Cas A and in HESS J1731-347, for which carbon atmosphere models were used to reconcile their emission with the known or estimated distances.

  8. An occurrence of the protocetid whale "Eocetus" wardii in the middle Eocene Piney Point Formation of Virginia

    USGS Publications Warehouse

    Weems, R.E.; Edwards, L.E.; Osborne, J.E.; Alford, A.A.

    2011-01-01

    Two protocetid whale vertebrae, here referred to “Eocetus” wardii, have been recovered from the riverbed of the Pamunkey River in east-central Virginia. Neither bone was found in situ, but both were found with lumps of lithified matrix cemented to their surfaces. Most of this matrix was removed and processed for microfossils. Specimens of dinoflagellates were successfully recovered and this flora clearly demonstrates that both vertebrae came from the middle Eocene Piney Point Formation, which crops out above and below river level in the area where the bones were discovered. These vertebrae are the oldest whale remains reported from Virginia and are as old as any cetacean remains known from the western hemisphere.

  9. Application of microprocessors in an upper atmosphere instrument package

    NASA Technical Reports Server (NTRS)

    Lim, T. S.; Ehrman, C. H.; Allison, S.

    1981-01-01

    A servo-driven magnetometer table measuring offset from magnetic north has been developed by NASA to calculate payload azimuth required to point at a celestial target. Used as an aid to the study of gamma-ray phenomena, the high-altitude balloon-borne instrument determines a geocentric reference system, and calculates a set of pointing directions with respect to the system. Principal components include the magnetometer, stepping motor, microcomputer, and gray code shaft encoder. The single-chip microcomputer is used to control the orientation of the system, and consists of a central processing unit, program memory, data memory and input/output ports. Principal advantages include a low power requirement, consuming 6 watts, as compared to 30 watts consumed by the previous system.

  10. Kingdom Animalia: the zoological malaise from a microbial perspective

    NASA Technical Reports Server (NTRS)

    Margulis, L.

    1990-01-01

    Pain and cognitive dissonance abounds amongst biologists: the plant-animal, botany-zoology wound has nearly healed and the new gash--revealed by department and budget reorganizations--is "molecular" vs. "organismic" biology. Here I contend that resolution of these tensions within zoology requires that an autopoietic-gaian view replace a mechanical-neodarwinian perspective; in the interest of brevity and since many points have been discussed elsewhere, rather than develop detailed arguments I must make staccato statements and refer to a burgeoning literature. The first central concept is that animals, all organisms developing from blastular embryos, evolved from single protist cells that were unable to reproduce their undulipodia. The second points to the usefulness of recognizing the analogy between cyclically established symbioses and meiotic sexuality.

  11. Improving understanding of trigger points and widespread pressure pain sensitivity in tension-type headache patients: clinical implications.

    PubMed

    Fernández-De-Las-Peñas, César; Arendt-Nielsen, Lars

    2017-09-01

    The underlying etiology of tension type headache (TTH) is not understood. The current paper highlights the etiologic role of muscle trigger points (TrPs) to the development and maintenance of central sensitization in TTH and its clinical repercussion for proper management of these patients. Areas covered: A literature search on Pub Med for English-language published papers between 1990 and May 2017 to provide the most updated data on the topic was conducted. Current literature suggests that the referred pain elicited by active trigger points (TrPs) contributes to the manifestations of TTH. There is also evidence supporting that TrPs represent a peripheral source of nociception and thereby a driver in the development of central sensitization. In fact, TrPs have been found to be associated with widespread pressure pain sensitivity in TTH. Temporal and spatial summation of TrP nociception suggests that inactivating TrP in the neck, head and shoulder muscles could help these patients; however, current evidence supporting the therapeutic role of TrPs in TTH is conflicting. Expert commentary: Understanding the role of TrPs in TTH in widespread pain sensitization may help to develop better management regimes and possibly prevent TTH from developing into more chronic conditions.

  12. A Proposal of New Reference System for the Standard Axial, Sagittal, Coronal Planes of Brain Based on the Serially-Sectioned Images

    PubMed Central

    Park, Jin Seo; Park, Hyo Seok; Shin, Dong Sun; Har, Dong-Hwan; Cho, Zang-Hee; Kim, Young-Bo; Han, Jae-Yong; Chi, Je-Geun

    2010-01-01

    Sectional anatomy of human brain is useful to examine the diseased brain as well as normal brain. However, intracerebral reference points for the axial, sagittal, and coronal planes of brain have not been standardized in anatomical sections or radiological images. We made 2,343 serially-sectioned images of a cadaver head with 0.1 mm intervals, 0.1 mm pixel size, and 48 bit color and obtained axial, sagittal, and coronal images based on the proposed reference system. This reference system consists of one principal reference point and two ancillary reference points. The two ancillary reference points are the anterior commissure and the posterior commissure. And the principal reference point is the midpoint of two ancillary reference points. It resides in the center of whole brain. From the principal reference point, Cartesian coordinate of x, y, z could be made to be the standard axial, sagittal, and coronal planes. PMID:20052359

  13. Referred pain elicited by manual exploration of the lateral rectus muscle in chronic tension-type headache.

    PubMed

    Fernández-de-Las-Peñas, César; Cuadrado, Maria Luz; Gerwin, Robert D; Pareja, Juan A

    2009-01-01

    To analyze the presence of referred pain elicited by manual examination of the lateral rectus muscle in patients with chronic tension-type headache (CTTH). A case-control blinded study. It has been found previously that the manual examination of the superior oblique muscle can elicit referred pain to the head in some patients with migraine or tension-type headache. However, a referred pain from other extraocular muscles has not been investigated. Fifteen patients with CTTH and 15 healthy subjects without headache history were included. A blinded assessor performed a manual examination focused on the search for myofascial trigger points (TrPs) in the right and left lateral rectus muscles. TrP diagnosis was made when there was referred pain evoked by maintained pressure on the lateral corner of the orbit (anatomical projection of the lateral rectus muscle) for 20 seconds, and increased referred pain while the subject maintained a medial gaze on the corresponding side (active stretching of the muscle) for 15 seconds. On each side, a 10-point numerical pain rate scale was used to assess the intensity of referred pain at both stages of the examination. Ten patients with CTTH (66.6%) had referred pain that satisfied TrPs diagnostic criteria, while only one healthy control (0.07%) reported referred pain upon the examination of the lateral rectus muscles (P < 0.001). The elicited referred pain was perceived as a deep ache located at the supraorbital region or the homolateral forehead. Pain was evoked on both sides in all subjects with TrPs, with no difference in pain intensity between the right and the left. The average pain intensity was significantly greater in the patient group (P < 0.001). All CTTH patients with referred pain recognized it as the frontal pain that they usually experienced during their headache attacks, which was consistent with active TrPs. In some patients with CTTH, the manual examination of lateral rectus muscle TrPs elicits a referred pain that extends to the supraorbital region or the homolateral forehead. Nociceptive inputs from the extraocular muscles may sustain the activation of trigeminal neuron, thus sensitizing central pain pathways and exacerbating headache.

  14. Puget Sound Dredged Disposal Analysis (PSDDA). Final Environmental Impact Statement Unconfined Open-Water Disposal for Dredged Material, Phase 2. (North and South Puget Sound)

    DTIC Science & Technology

    1989-09-01

    flathead sole, rex sole, and rock sole all showed indications of blood worm infestations. One liver tumor was found in a rex sole during spring in the ZSF...concentrations Hainly in invertebrates; some trations (.01 ppb) in waters (from lOx to 42Ox reference) in fish livers ; rarely in fish of Puget Sound central...Eagle Harbor, and Sinclair fish livers , and birds in Inlet. Highest elevation industrialized ’-ban areas. along Ruston-Point Defiance Copper is a natural

  15. Variable frequency microprocessor clock generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branson, C.N.

    A microprocessor-based system is described comprising: a digital central microprocessor provided with a clock input and having a rate of operation determined by the frequency of a clock signal input thereto; memory means operably coupled to the central microprocessor for storing programs respectively including a plurality of instructions and addressable by the central microprocessor; peripheral device operably connected to the central microprocessor, the first peripheral device being addressable by the central microprocessor for control thereby; a system clock generator for generating a digital reference clock signal having a reference frequency rate; and frequency rate reduction circuit means connected between themore » clock generator and the clock input of the central microprocessor for selectively dividing the reference clock signal to generate a microprocessor clock signal as an input to the central microprocessor for clocking the central microprocessor.« less

  16. Once more on the equilibrium-point hypothesis (lambda model) for motor control.

    PubMed

    Feldman, A G

    1986-03-01

    The equilibrium control hypothesis (lambda model) is considered with special reference to the following concepts: (a) the length-force invariant characteristic (IC) of the muscle together with central and reflex systems subserving its activity; (b) the tonic stretch reflex threshold (lambda) as an independent measure of central commands descending to alpha and gamma motoneurons; (c) the equilibrium point, defined in terms of lambda, IC and static load characteristics, which is associated with the notion that posture and movement are controlled by a single mechanism; and (d) the muscle activation area (a reformulation of the "size principle")--the area of kinematic and command variables in which a rank-ordered recruitment of motor units takes place. The model is used for the interpretation of various motor phenomena, particularly electromyographic patterns. The stretch reflex in the lambda model has no mechanism to follow-up a certain muscle length prescribed by central commands. Rather, its task is to bring the system to an equilibrium, load-dependent position. Another currently popular version defines the equilibrium point concept in terms of alpha motoneuron activity alone (the alpha model). Although the model imitates (as does the lambda model) spring-like properties of motor performance, it nevertheless is inconsistent with a substantial data base on intact motor control. An analysis of alpha models, including their treatment of motor performance in deafferented animals, reveals that they suffer from grave shortcomings. It is concluded that parameterization of the stretch reflex is a basis for intact motor control. Muscle deafferentation impairs this graceful mechanism though it does not remove the possibility of movement.

  17. The Role of Celestial Compass Information in Cataglyphis Ants during Learning Walks and for Neuroplasticity in the Central Complex and Mushroom Bodies

    PubMed Central

    Grob, Robin; Fleischmann, Pauline N.; Grübel, Kornelia; Wehner, Rüdiger; Rössler, Wolfgang

    2017-01-01

    Central place foragers are faced with the challenge to learn the position of their nest entrance in its surroundings, in order to find their way back home every time they go out to search for food. To acquire navigational information at the beginning of their foraging career, Cataglyphis noda performs learning walks during the transition from interior worker to forager. These small loops around the nest entrance are repeatedly interrupted by strikingly accurate back turns during which the ants stop and precisely gaze back to the nest entrance—presumably to learn the landmark panorama of the nest surroundings. However, as at this point the complete navigational toolkit is not yet available, the ants are in need of a reference system for the compass component of the path integrator to align their nest entrance-directed gazes. In order to find this directional reference system, we systematically manipulated the skylight information received by ants during learning walks in their natural habitat, as it has been previously suggested that the celestial compass, as part of the path integrator, might provide such a reference system. High-speed video analyses of distinct learning walk elements revealed that even exclusion from the skylight polarization pattern, UV-light spectrum and the position of the sun did not alter the accuracy of the look back to the nest behavior. We therefore conclude that C. noda uses a different reference system to initially align their gaze directions. However, a comparison of neuroanatomical changes in the central complex and the mushroom bodies before and after learning walks revealed that exposure to UV light together with a naturally changing polarization pattern was essential to induce neuroplasticity in these high-order sensory integration centers of the ant brain. This suggests a crucial role of celestial information, in particular a changing polarization pattern, in initially calibrating the celestial compass system. PMID:29184487

  18. The Role of Celestial Compass Information in Cataglyphis Ants during Learning Walks and for Neuroplasticity in the Central Complex and Mushroom Bodies.

    PubMed

    Grob, Robin; Fleischmann, Pauline N; Grübel, Kornelia; Wehner, Rüdiger; Rössler, Wolfgang

    2017-01-01

    Central place foragers are faced with the challenge to learn the position of their nest entrance in its surroundings, in order to find their way back home every time they go out to search for food. To acquire navigational information at the beginning of their foraging career, Cataglyphis noda performs learning walks during the transition from interior worker to forager. These small loops around the nest entrance are repeatedly interrupted by strikingly accurate back turns during which the ants stop and precisely gaze back to the nest entrance-presumably to learn the landmark panorama of the nest surroundings. However, as at this point the complete navigational toolkit is not yet available, the ants are in need of a reference system for the compass component of the path integrator to align their nest entrance-directed gazes. In order to find this directional reference system, we systematically manipulated the skylight information received by ants during learning walks in their natural habitat, as it has been previously suggested that the celestial compass, as part of the path integrator, might provide such a reference system. High-speed video analyses of distinct learning walk elements revealed that even exclusion from the skylight polarization pattern, UV-light spectrum and the position of the sun did not alter the accuracy of the look back to the nest behavior. We therefore conclude that C. noda uses a different reference system to initially align their gaze directions. However, a comparison of neuroanatomical changes in the central complex and the mushroom bodies before and after learning walks revealed that exposure to UV light together with a naturally changing polarization pattern was essential to induce neuroplasticity in these high-order sensory integration centers of the ant brain. This suggests a crucial role of celestial information, in particular a changing polarization pattern, in initially calibrating the celestial compass system.

  19. Central poststroke pain: an abstruse outcome.

    PubMed

    Henry, James L; Lalloo, Chitra; Yashpal, Kiran

    2008-01-01

    Central poststroke pain (CPSP), formerly known as thalamic pain syndrome of Déjerine and Roussy, is a central neuropathic pain occurring in patients affected by stroke. It is one manifestation of central pain, which is broadly defined as central neuropathic pain caused by lesions or dysfunction in the central nervous system. Thalamic pain was first described 100 years ago by Déjerine and Roussy and has been described as "among the most spectacular, distressing, and intractable of pain syndromes". CPSP is characterized by constant or intermittent pain and is associated with sensory abnormalities, particularly of thermal sensation. While the pain is frequently described as burning, scalding, or burning and freezing, other symptoms are usually vague and hard to characterize, making an early diagnosis particularly difficult. In fact, those who develop CPSP may no longer be under the care of health care professionals when their symptoms begin to manifest, resulting in misdiagnosis or a significant delay before treatment begins. Diagnosis is further complicated by cognitive and speech limitations that may occur following stroke, as well as by depression, anxiety and sleep disturbances. Patients may also exhibit spontaneous dysesthesia and the stimulus-evoked sensory disturbances of dysesthesia, allodynia and hyperalgesia. The present study offers a historical reference point for future clinical and basic research into this elusive type of debilitating pain.

  20. Central poststroke pain: An abstruse outcome

    PubMed Central

    Henry, James L; Lalloo, Chitra; Yashpal, Kiran

    2008-01-01

    Central poststroke pain (CPSP), formerly known as thalamic pain syndrome of Déjerine and Roussy, is a central neuropathic pain occurring in patients affected by stroke. It is one manifestation of central pain, which is broadly defined as central neuropathic pain caused by lesions or dysfunction in the central nervous system. Thalamic pain was first described 100 years ago by Déjerine and Roussy and has been described as “among the most spectacular, distressing, and intractable of pain syndromes”. CPSP is characterized by constant or intermittent pain and is associated with sensory abnormalities, particularly of thermal sensation. While the pain is frequently described as burning, scalding, or burning and freezing, other symptoms are usually vague and hard to characterize, making an early diagnosis particularly difficult. In fact, those who develop CPSP may no longer be under the care of health care professionals when their symptoms begin to manifest, resulting in misdiagnosis or a significant delay before treatment begins. Diagnosis is further complicated by cognitive and speech limitations that may occur following stroke, as well as by depression, anxiety and sleep disturbances. Patients may also exhibit spontaneous dysesthesia and the stimulus-evoked sensory disturbances of dysesthesia, allodynia and hyperalgesia. The present study offers a historical reference point for future clinical and basic research into this elusive type of debilitating pain. PMID:18301815

  1. Looking for a Symphony: A Sort of Essay with a Perspective on Activity Theories and the Ontology of Psychology: Learning from Danish and Russian Experiences by Jens Mammen & Irina Mironenko.

    PubMed

    Neumann, Asger

    2016-06-01

    As a perspective on Mammen and Miroenkos the article is reflecting on the possibility of Activity Theory being a foundation on which Psychology could be integrated. Mammen and Miroenkos point that directed activity not only is towards objects "defined as a sum of qualities, but by individual reference" is a starting point. As a specific example the phenomenon Love, as "significant object relations", is related to the concept "choice categories". It is stated that relations of affection and love can't be understood independent of history of common activity, and that this makes the concept "choice categories" central in a psychological understanding of what love is.

  2. Sociology of health textbooks and narratives: historical significance.

    PubMed

    Nunes, Everardo Duarte

    2016-03-01

    This article has as its starting point two central ideas: textbooks as a means of production and dissemination of knowledge and narrative as an approach. After a brief review of studies on health/medical sociology textbooks, I analyze a few of these textbooks from the 1900-2012 period, produced in the United States and England. I have selected eleven textbooks which I thought were representative. In addition to a content analysis, the textbooks are located within the process of constitution of the health/medical sociology with brief references to the biographies of the authors. The textbooks analyzed were classified according to the main narrative features: doctor-centered; interdisciplinary; pedagogical; analytical; almost autobiographical; critical; and synthetic-reflective. In the final remarks, some points about the textbooks, limits and possibilities are presented.

  3. Archaeomagnetic studies in central Mexico—dating of Mesoamerican lime-plasters

    NASA Astrophysics Data System (ADS)

    Hueda-Tanabe, Y.; Soler-Arechalde, A. M.; Urrutia-Fucugauchi, J.; Barba, L.; Manzanilla, L.; Rebolledo-Vieyra, M.; Goguitchaichvili, A.

    2004-11-01

    For the first time results of an archaeomagnetic study of unburned lime-plasters from Teotihuacan and Tenochtitlan in central Mesoamerica are presented. Plasters made of lime, lithic clasts and water, appear during the Formative Period and were used for a variety of purposes in floors, sculptures, ceramics and supporting media for mural paintings in the Oaxaca and Maya area. In Central Mexico, grinded volcanic scoria rich in iron minerals is incorporated into the lime-plasters mixture. Samples were selected from two archaeological excavation projects in the Teopancazco residential compound of Teotihuacan and the large multi-stage structure of Templo Mayor in Tenochtitlan, where chronological information is available. The intensity of remanent magnetization (natural remanent magnetization (NRM)) and low-field susceptibility are weak reflecting low relative content of magnetic minerals. NRM directions are well grouped and alternating field demagnetization shows single or two-component magnetizations. Rockmagnetic experiments point to fine-grained titanomagnetites with pseudo-single domain behavior. Anisotropy of magnetic susceptibility (AMS) measurements document a depositional fabric, with normal to free-surface minimum AMS axes. Characteristic mean site directions were correlated to the paleosecular variation curve for Mesoamerica. Data from Templo Mayor reflect recent tilting of the structures. Teopancazco mean site declinations show good correspondence with the reference curve, in agreement with the radiocarbon dating. Dates for four stages of Teotihuacan occupancy based on the study of lime-plasters range from AD 350 to 550. A date for a possible Mazapa occupation around AD 850 or 950 is also suggested based on the archaeomagnetic correlation. The archaeomagnetic record of a plaster floor in Teopancazco differed from the other nearby sites pointing to a thermoremanent magnetization; comparison with the reference curve suggests dates around AD 1375 or 1415. The burning of the stucco floor likely occurred during a late re-occupation of the site by the Aztecs. Our results suggest that archaeomagnetic dating can be applied to lime-plasters, which are materials widely employed in Mesoamerica.

  4. Exploring the reference point in prospect theory: gambles for length of life.

    PubMed

    van Osch, Sylvie M C; van den Hout, Wilbert B; Stiggelbout, Anne M

    2006-01-01

    Attitude toward risk is an important factor determining patient preferences. Risk behavior has been shown to be strongly dependent on the perception of the outcome as either a gain or a loss. According to prospect theory, the reference point determines how an outcome is perceived. However, no theory on the location of the reference point exists, and for the health domain, there is no direct evidence for the location of the reference point. This article combines qualitative with quantitative data to provide evidence of the reference point in life-year certainty equivalent (CE) gambles and to explore the psychology behind the reference point. The authors argue that goals (aspirations) in life influence the reference point. While thinking aloud, 45 healthy respondents gave certainty equivalents for life-year CE gambles with long and short durations of survival. Contrary to suggestions from the literature, qualitative data argued that the offered certainty equivalent most frequently served as the reference point. Thus, respondents perceived life-year CE gambles as mixed. Framing of the question and goals set in life appeared to be important factors behind the psychology of the reference point. On the basis of the authors' quantitative and qualitative data, they argue that goals alter the perception of outcomes as described by prospect theory by influencing the reference point. This relationship is more apparent for the near future as opposed to the remote future, as goals are mostly set for the near future.

  5. [Bibliographical study of the toxicity of organic mercury compounds].

    PubMed

    Ishihara, Nobuo

    2011-09-01

    The aim of this study is to correct the misunderstanding that the toxicity of organic mercury compounds is unknown at the time of the outbreak of Minamata disease (May 1, 1956). Two case reports of organic mercury (methylmercury) intoxication were published already in 1865 and 1866. The conversion of inorganic mercury added in acetoaldehyde synthesis was already pointed out in 1921. In 1930 several cases of organic mercury poisoning among workers engaged in acetoaldehyde production were reported. Many reports on not only in occupational exposure but a oral exposure via the ingestion of flour made from grains treated with organic mercurials were available at the time of the outbreak of Minamata disease (May 1, 1956). These reports pointed out the toxic effects of organic mercury on the central nervous system, and indicated cleary that the causal substance of Minamata disease must be the organic mercury compounds (methylmercury) from the Chisso plant. The identification of methylmercury as the causal substance by the authority was presented in 1968 when acetoaldehyde production in the Chisso plant was closed. Most of these reports except that of (Hunter et al.) were not referred to in the study of Minamata disease . Inadequate referencing should be pointed out. Several reports indicated that the causal substance of Minamata disease must be methylmercury from the Chisso Plant. However, most of these reports were not referred to during the study of Minamata disease. Inadequate referencing of literatures should be pointed out.

  6. A plea for judgment.

    PubMed

    Davis, Michael

    2012-12-01

    Judgment is central to engineering, medicine, the sciences and many other practical activities. For example, one who otherwise knows what engineers know but lacks "engineering judgment" may be an expert of sorts, a handy resource much like a reference book or database, but cannot be a competent engineer. Though often overlooked or at least passed over in silence, the central place of judgment in engineering, the sciences, and the like should be obvious once pointed out. It is important here because it helps to explain where ethics fits into these disciplines. There is no good engineering, no good science, and so on without good judgment and no good judgment in these disciplines without ethics. Doing even a minimally decent job of teaching one of these disciplines necessarily includes teaching its ethics; teaching the ethics is teaching the discipline (or at least a large part of it).

  7. A Cross-Cultural Study of Reference Point Adaptation: Evidence from China, Korea, and the US

    ERIC Educational Resources Information Center

    Arkes, Hal R.; Hirshleifer, David; Jiang, Danling; Lim, Sonya S.

    2010-01-01

    We examined reference point adaptation following gains or losses in security trading using participants from China, Korea, and the US. In both questionnaire studies and trading experiments with real money incentives, reference point adaptation was larger for Asians than for Americans. Subjects in all countries adapted their reference points more…

  8. Possible generational effects of habitat degradation on alligator reproduction

    USGS Publications Warehouse

    Fujisaki, Ikuko; Rice, K.G.; Woodward, A.R.; Percival, H.F.

    2007-01-01

    Population decline of the American alligator (Alligator mississippiensis) was observed in Lake Apopka in central Florida, USA, in the early 1980s. This decline was thought to result from adult mortality and nest failure caused by anthropogenic increases in sediment loads, nutrients, and contaminants. Reproductive impairment also was reported. Extensive restoration of marshes associated with Lake Apopka has been conducted, as well as some limited restoration measures on the lake. Monitoring by the Florida Fish and Wildlife Conservation Commission (FFWCC) has indicated that the adult alligator population began increasing in the early 1990s. We expected that the previously reported high proportion of complete nest failure (??0) during the 1980s may have decreased. We collected clutches from alligator nests in Lake Apopka from 1983 to 2003 and from 5 reference areas from 1988 to 1991, and we artificially incubated them. We used a Bayesian framework with Gibbs sampler of Markov chain Monte Carlo simulation to analyze ??0. Estimated ??0was consistently higher in Lake Apopka compared with reference areas, and the difference in ??0 ranged from 0.19 to 0.56. We conducted change point analysis to identify and test the significance of the change point in ??0in Lake Apopka between 1983 and 2003, indicating the point of reproductive recovery. The estimated Bayes factor strongly supported the single change point hypothesis against the no change point hypothesis. The major downward shift in ??0 probably occurred in the mid-1990s, approximately a generation after the major population decline in the 1980s. Furthermore, estimated ??0 values after the change point (0.21) were comparable with those of reference areas (0.07-0.31). These results combined with the monitoring by FFWCC seem to suggest that anthropogenic habitat degradation caused reproductive impairment of adult females and decreases in ??0 occurred with the sexual maturity of a new generation of breeding females. Long-term monitoring is essential to understand population changes due to habitat restoration. Such information can be used as an input in planning and evaluating restoration activities.

  9. Point-of-care device to diagnose and monitor neonatal jaundice in low-resource settings

    PubMed Central

    Keahey, Pelham A.; Simeral, Mathieu L.; Schroder, Kristofer J.; Bond, Meaghan M.; Mtenthaonnga, Prince J.; Miros, Robert H.; Dube, Queen

    2017-01-01

    Newborns are at increased risk of jaundice, a condition in which excess bilirubin accumulates in blood. Left untreated, jaundice can lead to neurological impairment and death. Jaundice resulting from unconjugated hyperbilirubinemia is easily treated with exposure to blue light, and phototherapy systems have been developed for low-resource settings; however, there are no appropriate solutions to diagnose and monitor jaundice in these settings. To address this need we present BiliSpec, a low-cost reader and disposable lateral flow card designed to measure the concentration of total bilirubin from several drops of blood at the point of care. We evaluated the performance of BiliSpec, using blood from normal volunteers spiked with varying amounts of bilirubin; results measured using BiliSpec correlated well with a reference laboratory bilirubinometer (r = 0.996). We then performed a pilot clinical study using BiliSpec to measure total bilirubin in neonates at risk for jaundice at Queen Elizabeth Central Hospital in Blantyre, Malawi. Concentrations measured using BiliSpec correlated well with those measured using a laboratory reference standard in 94 patient samples ranging from 1.1 mg/dL to 23.0 mg/dL in concentration (r = 0.973). The mean difference between bilirubin levels measured with BiliSpec and the reference standard was 0.3 mg/dL (95% CI: −1.7–2.2 mg/dL). PMID:29203650

  10. Clinical utility of Abbott Precision Xceed Pro® ketone meter in diabetic patients.

    PubMed

    Yu, Hoi-Ying Elsie; Agus, Michael; Kellogg, Mark D

    2011-11-01

    Diagnosis and management of diabetic ketoacidosis (DKA) often rely on the measurement of urine ketones along with blood glucose, anion gap, and pH. These values, however, do not reliably reflect the severity of ketoacidosis. The Abbott Precision Xceed Pro® meter is an FDA-approved device that quantitatively measures β-hydroxybutyrate (BOH) in whole blood. This study was undertaken to determine whether the ketone meter meets the analytical criteria to aid DKA diagnosis and management in the hospital. 54 heparinized venous whole blood BOH concentrations from 27 diabetic patients were measured by the Abbott meter, and compared with the plasma BOH concentrations measured with Stanbio reagent (reference method). Measurements were done in the hospital central laboratory. Of the 54 pairs of specimens analyzed, 17 pairs displayed a difference of >15% between the two methods. Nearly all discrepant points occurred when BOH >5 mmol/L (reference method). Linearity evaluation revealed that the meter is not linear from 0.0 to 8.0 mmol/L, contrary to the claim by the manufacturer. Further, we identified acetoacetate, a metabolite commonly present in DKA patients, as a potential interfering substance for the meter BOH measurement. BOH measurements by the Abbott meter up to 3 mmol/L correlate well with the reference method, but become discrepant above that point. While this characteristic may be useful in the diagnosis of DKA, it may not allow clinicians to serially follow the response to therapy in hospitalized DKA patients with BOH values greater than 5 mmol/L (reference method). © 2011 John Wiley & Sons A/S.

  11. An Integrated Chemical Environment to Support 21st-Century Toxicology.

    PubMed

    Bell, Shannon M; Phillips, Jason; Sedykh, Alexander; Tandon, Arpit; Sprankle, Catherine; Morefield, Stephen Q; Shapiro, Andy; Allen, David; Shah, Ruchir; Maull, Elizabeth A; Casey, Warren M; Kleinstreuer, Nicole C

    2017-05-25

    SUMMARY : Access to high-quality reference data is essential for the development, validation, and implementation of in vitro and in silico approaches that reduce and replace the use of animals in toxicity testing. Currently, these data must often be pooled from a variety of disparate sources to efficiently link a set of assay responses and model predictions to an outcome or hazard classification. To provide a central access point for these purposes, the National Toxicology Program Interagency Center for the Evaluation of Alternative Toxicological Methods developed the Integrated Chemical Environment (ICE) web resource. The ICE data integrator allows users to retrieve and combine data sets and to develop hypotheses through data exploration. Open-source computational workflows and models will be available for download and application to local data. ICE currently includes curated in vivo test data, reference chemical information, in vitro assay data (including Tox21 TM /ToxCast™ high-throughput screening data), and in silico model predictions. Users can query these data collections focusing on end points of interest such as acute systemic toxicity, endocrine disruption, skin sensitization, and many others. ICE is publicly accessible at https://ice.ntp.niehs.nih.gov. https://doi.org/10.1289/EHP1759.

  12. An Integrated Chemical Environment to Support 21st-Century Toxicology

    PubMed Central

    Bell, Shannon M.; Phillips, Jason; Sedykh, Alexander; Tandon, Arpit; Sprankle, Catherine; Morefield, Stephen Q.; Shapiro, Andy; Allen, David; Shah, Ruchir; Maull, Elizabeth A.; Casey, Warren M.

    2017-01-01

    Summary: Access to high-quality reference data is essential for the development, validation, and implementation of in vitro and in silico approaches that reduce and replace the use of animals in toxicity testing. Currently, these data must often be pooled from a variety of disparate sources to efficiently link a set of assay responses and model predictions to an outcome or hazard classification. To provide a central access point for these purposes, the National Toxicology Program Interagency Center for the Evaluation of Alternative Toxicological Methods developed the Integrated Chemical Environment (ICE) web resource. The ICE data integrator allows users to retrieve and combine data sets and to develop hypotheses through data exploration. Open-source computational workflows and models will be available for download and application to local data. ICE currently includes curated in vivo test data, reference chemical information, in vitro assay data (including Tox21TM/ToxCast™ high-throughput screening data), and in silico model predictions. Users can query these data collections focusing on end points of interest such as acute systemic toxicity, endocrine disruption, skin sensitization, and many others. ICE is publicly accessible at https://ice.ntp.niehs.nih.gov. https://doi.org/10.1289/EHP1759 PMID:28557712

  13. Prevalence of myofascial trigger points in fibromyalgia: the overlap of two common problems.

    PubMed

    Ge, Hong-You

    2010-10-01

    With the objective evidence of their existence, myofascial trigger points (MTrPs) contribute to an increasing number of chronic regional and widespread pain conditions. The widespread spontaneous pain pattern in fibromyalgia (FM) is a summation of multiple regional pains due to active MTrPs. A regional pain in FM is from local active MTrPs and/or referred from remote active MTrPs. Positive tender points specified in FM are MTrPs, either active or latent. Manual stimulation of active MTrPs located in the muscles in different body regions completely reproduced overall spontaneous FM pain pattern. Active MTrPs as tonic peripheral nociceptive input contribute tremendously to the initiation and maintenance of central sensitization, to the impairment of descending inhibition, to the increased excitability of motor units, and to the induction of sympathetic hyperactivity observed in FM. The considerable overlap of MTrPs and FM in pain characteristics and pathophysiology suggests that FM pain is largely due to MTrPs.

  14. The 'new normal': relativity of quality of life judgments in individuals with bipolar disorder-a qualitative study.

    PubMed

    Morton, Emma; Michalak, Erin; Hole, Rachelle; Buzwell, Simone; Murray, Greg

    2018-06-01

    Quality of life (QoL) is increasingly a target of interventions for bipolar disorders (BD). While the subjective experience of consumers is often elevated as central to the construct of QoL in BD, limited investigation in this area means subjective QoL remains poorly understood. The present qualitative study seeks to address this by investigating how people with BD appraise the quality of their lives in the context of a QoL self-management intervention. Semi-structured interviews were conducted with 43 individuals who had participated in a self-management intervention for improving QoL in BD. Individuals were questioned about experiences of the intervention and perceptions of their QoL. Thematic analysis was used to explore participants' appraisal of their QoL. An overarching theme concerned the intrinsic relativity of subjective QoL: individuals located QoL as relative to self, others and possible futures. Incorporating illness-related reference points for QoL ('given my circumstances…') was associated with perceptions of improved QoL. Deliberately modifying reference points for QoL was perceived as self-compassionate. The present study generates novel hypotheses about how individuals with BD make sense of their QoL. Data suggest that individuals located their QoL relative to a variety of reference points, use of which was flexible. In accord with gap theories of QoL, individuals experienced acceptance of illness impacts as improving subjective sense of QoL. Rather than 'settling for' a lower standard of QoL, individuals experienced these changes as adaptive and positive. Findings are discussed in relation to the measurement and amelioration of QoL in BD.

  15. LMS tables for waist circumference and waist–height ratio in Colombian adults: analysis of nationwide data 2010

    PubMed Central

    Ramírez-Vélez, R; Correa-Bautista, J E; Martínez-Torres, J; Méneses-Echavez, J F; González-Ruiz, K; González-Jiménez, E; Schmidt-RioValle, J; Lobelo, F

    2016-01-01

    Background/Objectives: Indices predictive of central obesity include waist circumference (WC) and waist-to-height ratio (WHtR). These data are lacking for Colombian adults. This study aims at establishing smoothed centile charts and LMS tables for WC and WHtR; appropriate cutoffs were selected using receiver-operating characteristic analysis based on data from the representative sample. Subjects/Methods: We used data from the cross-sectional, national representative nutrition survey (ENSIN, 2010). A total of 83 220 participants (aged 20–64) were enroled. Weight, height, body mass index (BMI), WC and WHtR were measured and percentiles calculated using the LMS method (L (curve Box-Cox), M (curve median), and S (curve coefficient of variation)). Receiver operating characteristics curve analyses were used to evaluate the optimal cutoff point of WC and WHtR for overweight and obesity based on WHO definitions. Results: Reference values for WC and WHtR are presented. Mean WC and WHtR increased with age for both genders. We found a strong positive correlation between WC and BMI (r=0.847, P< 0.01) and WHtR and BMI (r=0.878, P<0.01). In obese men, the cutoff point value is 96.6 cm for the WC. In women, the cutoff point value is 91.0 cm for the WC. Receiver operating characteristic curve for WHtR was also obtained and the cutoff point value of 0.579 in men, and in women the cutoff point value was 0.587. A high sensitivity and specificity were obtained. Conclusions: This study presents first reference values of WC and WHtR for Colombians aged 20–64. Through LMS tables for adults, we hope to provide quantitative tools to study obesity and its complications. PMID:27026425

  16. Near-field spectral shift of a zero-order Bessel beam scattered from a spherical particle

    NASA Astrophysics Data System (ADS)

    Chen, Feinan; Li, Jia; Belafhal, Abdelmajid; Chafiq, Abdelghani; Sun, Xiaobing

    2018-06-01

    Within the accuracy of the first-order Born approximation, expressions are derived for the near-zone spectrum of a zero-order Bessel beam scattered from a spherical particle whose correlation function satisfies a Gaussian distribution. The dependence of the spectral shift and spectral switch of the scattered field on the effective size of the scattering potential (ESSP) are determined by numerical simulations. It is shown that the spectral shift of the scattered field does not occur along the longitudinal propagation direction. Furthermore, when the medium’s ESSP is comparable with the central wavelength of the beam, the spectrum of the scattered field loses the Gaussian distribution and exhibits a blue shift as the reference point sufficiently far away from central origin. These results may have prospective applications in guiding tiny particles when the near-zone spectrums of scattered beams are captured and analyzed.

  17. 75 FR 73128 - Certain Printing and Imaging Devices and Components Thereof; Notice of Commission Determination...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ...'' include any line extending parallel to the central axis of the roller? Or, does this refer to the central... ``a longitudinal direction'' can include any line extending parallel to the central axis of the roller...) The finding that the Taylor reference (``A Telerobot on the World Wide Web'') (RX-281) does not...

  18. Here, There, and Everywhere: Reference at the Point-of-Need.

    ERIC Educational Resources Information Center

    Trump, Judith F.; Tuttle, Ian P.

    2001-01-01

    Growing numbers of libraries are experimenting with a new form of interactive reference to extend service to their patrons at the point-of-need and time-of-need. Examines digital reference for the altered user culture and point-of-need service products. Describes a pilot project offering chat reference service. Discuses developing service…

  19. GFT centrality: A new node importance measure for complex networks

    NASA Astrophysics Data System (ADS)

    Singh, Rahul; Chakraborty, Abhishek; Manoj, B. S.

    2017-12-01

    Identifying central nodes is very crucial to design efficient communication networks or to recognize key individuals of a social network. In this paper, we introduce Graph Fourier Transform Centrality (GFT-C), a metric that incorporates local as well as global characteristics of a node, to quantify the importance of a node in a complex network. GFT-C of a reference node in a network is estimated from the GFT coefficients derived from the importance signal of the reference node. Our study reveals the superiority of GFT-C over traditional centralities such as degree centrality, betweenness centrality, closeness centrality, eigenvector centrality, and Google PageRank centrality, in the context of various arbitrary and real-world networks with different degree-degree correlations.

  20. Geometric registration of images by similarity transformation using two reference points

    NASA Technical Reports Server (NTRS)

    Kang, Yong Q. (Inventor); Jo, Young-Heon (Inventor); Yan, Xiao-Hai (Inventor)

    2011-01-01

    A method for registering a first image to a second image using a similarity transformation. The each image includes a plurality of pixels. The first image pixels are mapped to a set of first image coordinates and the second image pixels are mapped to a set of second image coordinates. The first image coordinates of two reference points in the first image are determined. The second image coordinates of these reference points in the second image are determined. A Cartesian translation of the set of second image coordinates is performed such that the second image coordinates of the first reference point match its first image coordinates. A similarity transformation of the translated set of second image coordinates is performed. This transformation scales and rotates the second image coordinates about the first reference point such that the second image coordinates of the second reference point match its first image coordinates.

  1. The usefulness of rapid point-of-care creatinine testing for the prevention of contrast-induced nephropathy in the emergency department.

    PubMed

    You, Je Sung; Chung, Yong Eun; Park, Jong Woo; Lee, Woonhyoung; Lee, Hye-Jeong; Chung, Tae Nyoung; Chung, Sung Phil; Park, Incheol; Kim, Seungho

    2013-07-01

    Renal dysfunction is the most important factor to consider when predicting a patient's risk of developing contrast-induced nephropathy (CIN). Measurement of creatinine (Cr) via rapid point-of-care blood urea nitrogen/creatinine testing (POCT-BUN/Cr) to determine CIN risk could potentially reduce the time required to achieve an accurate diagnosis and to initiate and complete treatment in the emergency department (ED). The aim of our study was to compare the results of POCT-BUN/Cr and reference laboratory tests for BUN and serum Cr. A retrospective analysis of suspected stroke patients who presented between November 2009 and November 2010, and had BUN and Cr levels measured by POCT-BUN/Cr, and the reference laboratory tests performed with the blood sample which was transferred to the central laboratory by an air-shoot system. Two assays were conducted on the whole blood (POCT) and serum (reference) by trained technicians. The time interval from arrival at the ED to reporting of the results was assessed for both assays via a computerised physician order entry system. The mean standard deviation (SD) interval from arrival at the ED to reporting of the results was 11.4 (4.9) min for POCT-BUN/Cr and 46.8 (38.5) min for the serum reference laboratory tests (p<0.001). Intra-class correlation coefficient (ICC) analysis demonstrated a high level of agreement (the consistency agreement) between POCT and the serum reference tests for both BUN (ICC=0.914) and Cr (ICC=0.980). This study suggests that POCT-BUN/Cr results correlate well with those of serum reference tests in terms of BUN and Cr levels and, in turn, predicting CIN. POCT-BUN/Cr is easily performed with a rapid turnaround time, suggesting its use in the ED may have substantial clinical benefit.

  2. Slump stretching in the management of non-radicular low back pain: a pilot clinical trial.

    PubMed

    Cleland, Joshua A; Childs, John D; Palmer, Jessica A; Eberhart, Sarah

    2006-11-01

    The purpose of this study was to determine if slump stretching results in improvements in pain, centralization of symptoms, and disability in patients with non-radicular low back pain (LBP) with likely mild to moderate neural mechanosensitivity. Thirty consecutive patients referred to physical therapy by their primary care physician for LBP who met all eligibility criteria including a positive slump test but who had a negative straight-leg-raise test (SLR) agreed to participate in the study. All patients completed several self-report measures including a body diagram, numeric pain rating scale (NPRS), and the modified Oswestry Disability Index (ODI). Patients were randomized to receive lumbar spine mobilization and exercise (n = 14) or lumbar spine mobilization, exercise, and slump stretching (n = 16). All patients were treated in physical therapy twice weekly for 3 weeks for a total of 6 visits. Upon discharge, outcome measures were re-assessed. Independent t-tests were used to assess differences between groups at baseline and discharge. No baseline differences existed between the groups (P > .05). At discharge, patients who received slump stretching demonstrated significantly greater improvements in disability (9.7 points on the ODI, P < .001), pain (.93 points on the NPRS, P = .001), and centralization of symptoms (P < .01) than patients who did not. The results suggest that slump stretching is beneficial for improving short-term disability, pain, and centralization of symptoms. Future studies should examine whether these benefits are maintained at a longer-term follow-up.

  3. Mandibular arch form: the relationship between dental and basal anatomy.

    PubMed

    Ronay, Valerie; Miner, R Matthew; Will, Leslie A; Arai, Kazuhito

    2008-09-01

    We investigated mandibular dental arch form at the levels of both the clinically relevant application points of the orthodontic bracket and the underlying anatomic structure of the apical base. The correlation of both forms was evaluated and examined to determine whether the basal arch could be used to derive a standardized clinical arch form. Thirty-five mandibular dental casts (skeletal and dental Class I) were laser scanned, and a 3-dimensional virtual model was created. Two reference points (FA, the most prominent part of the central lobe on each crown's facial surface, and WALA, a point at the height of the mucogingival junction) were selected for each tooth from the right to the left first molars. The FA and WALA arch forms were compared, and the distances between corresponding points and intercanine and intermolar widths were analyzed. Both arch forms were highly individual and the tooth values scattered. Nevertheless, a highly significant relationship between the FA and WALA curves was found, especially in the canine (0.75) and molar (0.87) areas. Both FA and WALA point-derived arch forms were individual and therefore could not be defined by a generalized shape. WALA points proved to be a useful representation of the apical base and helpful in the predetermination of an individualized dental arch form.

  4. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  5. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  6. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  7. 47 CFR 76.53 - Reference points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Reference points. 76.53 Section 76.53 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) BROADCAST RADIO SERVICES MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Carriage of Television Broadcast Signals § 76.53 Reference points. The...

  8. Passive serialization in a multitasking environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennessey, J.P.; Osisek, D.L.; Seigh, J.W. II

    1989-02-28

    In a multiprocessing system having a control program in which data objects are shared among processes, this patent describes a method for serializing references to a data object by the processes so as to prevent invalid references to the data object by any process when an operation requiring exclusive access is performed by another process, comprising the steps of: permitting the processes to reference data objects on a shared access basis without obtaining a shared lock; monitoring a point of execution of the control program which is common to all processes in the system, which occurs regularly in the process'more » execution and across which no references to any data object can be maintained by any process, except references using locks; establishing a system reference point which occurs after each process in the system has passed the point of execution at least once since the last such system reference point; requesting an operation requiring exclusive access on a selected data object; preventing subsequent references by other processes to the selected data object; waiting until two of the system references points have occurred; and then performing the requested operation.« less

  9. Synthetic Minor NSR Permit: BP America Production Company - Wolf Point Central Delivery Point

    EPA Pesticide Factsheets

    This page contains the response to public comments and the final synthetic minor NSR permit for the BP America Production Company, Wolf Point Central Delivery Point, located on the Southern Ute Indian Reservation in La Plata County, CO.

  10. Adaptive control of robotic manipulators

    NASA Technical Reports Server (NTRS)

    Seraji, H.

    1987-01-01

    The author presents a novel approach to adaptive control of manipulators to achieve trajectory tracking by the joint angles. The central concept in this approach is the utilization of the manipulator inverse as a feedforward controller. The desired trajectory is applied as an input to the feedforward controller which behaves as the inverse of the manipulator at any operating point; the controller output is used as the driving torque for the manipulator. The controller gains are then updated by an adaptation algorithm derived from MRAC (model reference adaptive control) theory to cope with variations in the manipulator inverse due to changes of the operating point. An adaptive feedback controller and an auxiliary signal are also used to enhance closed-loop stability and to achieve faster adaptation. The proposed control scheme is computationally fast and does not require a priori knowledge of the complex dynamic model or the parameter values of the manipulator or the payload.

  11. [Bioethics and the French speaking world: an answer to globalization].

    PubMed

    Byk, Christian

    2009-01-01

    Are we able, today, to take a step closer to bringing together the French speaking world and bioethics by realizing that their association could provide a profound view of the current evolution of our world characterized by what is referred to as globalization? Could we be even more ambitious and register the specificity of the rapport between the French speaking world and bioethics confronted with this global phenomenon of deconstruction/reconstruction of the planetary order by setting as its path a dynamic balance, which is an integral part of the use of the French language and cultural diversity, a central point in a truly pluridisciplinary and pluralist bioethics?

  12. Metabolic syndrome and obesity in peritoneal dialysis.

    PubMed

    Lo, Wai Kei

    2016-03-01

    Metabolic syndrome (MS) refers to clustering of features related to increased risk of cardiovascular disease, which include obesity or central obesity, dyslipidemia, diabetes mellitus or insulin resistance, together with hypertension. The prevalence of MS in end-stage renal failure patients on peritoneal dialysis is quite common, ranging from 40% to 60%, depending on the population studied and the definition used. However, there are controversies about the clinical outcome of patients with MS, particularly in the area of obesity. Whether peritoneal dialysis predisposes patients to MS is another unsolved issue. Despite these controversies, preventing patients from developing MS is important, at least from a theoretical point of view.

  13. 32 CFR 37.1040 - When and how do I report information required by § 37.1035?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the central point for reporting to the DTIC must be: (a) Submitted by the dates that your central point establishes (which is consistent with the schedule DTIC specifies to DoD Components). (b) In the format that your central point provides (which is consistent with the format that the DTIC specifies to...

  14. 32 CFR 37.1040 - When and how do I report information required by § 37.1035?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the central point for reporting to the DTIC must be: (a) Submitted by the dates that your central point establishes (which is consistent with the schedule DTIC specifies to DoD Components). (b) In the format that your central point provides (which is consistent with the format that the DTIC specifies to...

  15. 32 CFR 37.1040 - When and how do I report information required by § 37.1035?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the central point for reporting to the DTIC must be: (a) Submitted by the dates that your central point establishes (which is consistent with the schedule DTIC specifies to DoD Components). (b) In the format that your central point provides (which is consistent with the format that the DTIC specifies to...

  16. 32 CFR 37.1040 - When and how do I report information required by § 37.1035?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the central point for reporting to the DTIC must be: (a) Submitted by the dates that your central point establishes (which is consistent with the schedule DTIC specifies to DoD Components). (b) In the format that your central point provides (which is consistent with the format that the DTIC specifies to...

  17. Experimental Testing of a Generic Submarine Model in the DSTO Low Speed Wind Tunnel. Phase 2

    DTIC Science & Technology

    2014-03-01

    axis, z-axis (Nm) l Model reference length (1.35 m) L Lift force (N) MRP Moment Reference Point q Dynamic pressure       2 2 1 Uρ (Pa...moment reference point ( MRP ). The moment reference point was defined as the mid-length position on the centre-line of the model. Figure 5 presents the

  18. Reference-dependent preferences for maternity wards: an exploration of two reference points.

    PubMed

    Neuman, Einat

    2014-01-01

    It is now well established that a person's valuation of the benefit from an outcome of a decision is determined by the intrinsic "consumption utility" of the outcome itself and also by the relation of the outcome to some reference point. The most notable expression of such reference-dependent preferences is loss aversion. What precisely this reference point is, however, is less clear. This paper claims and provides empirical evidence for the existence of more than one reference point. Using a discrete choice experiment in the Israeli public health-care sector, within a sample of 219 women who had given birth, it is shown that respondents refer to two reference points : (i) a constant scenario that is used in the experiment; and (ii) also the actual state of the quantitative attributes of the service (number of beds in room of hospitalization; and travel time from residence to hospital). In line with the loss aversion theory, it is also shown that losses (vis-à-vis the constant scenario and vis-à-vis the actual state) accumulate and have reinforced effects, while gains do not.

  19. Phase-shifting point diffraction interferometer

    DOEpatents

    Medecki, H.

    1998-11-10

    Disclosed is a point diffraction interferometer for evaluating the quality of a test optic. In operation, the point diffraction interferometer includes a source of radiation, the test optic, a beam divider, a reference wave pinhole located at an image plane downstream from the test optic, and a detector for detecting an interference pattern produced between a reference wave emitted by the pinhole and a test wave emitted from the test optic. The beam divider produces separate reference and test beams which focus at different laterally separated positions on the image plane. The reference wave pinhole is placed at a region of high intensity (e.g., the focal point) for the reference beam. This allows reference wave to be produced at a relatively high intensity. Also, the beam divider may include elements for phase shifting one or both of the reference and test beams. 8 figs.

  20. Phase-shifting point diffraction interferometer

    DOEpatents

    Medecki, Hector

    1998-01-01

    Disclosed is a point diffraction interferometer for evaluating the quality of a test optic. In operation, the point diffraction interferometer includes a source of radiation, the test optic, a beam divider, a reference wave pinhole located at an image plane downstream from the test optic, and a detector for detecting an interference pattern produced between a reference wave emitted by the pinhole and a test wave emitted from the test optic. The beam divider produces separate reference and test beams which focus at different laterally separated positions on the image plane. The reference wave pinhole is placed at a region of high intensity (e.g., the focal point) for the reference beam. This allows reference wave to be produced at a relatively high intensity. Also, the beam divider may include elements for phase shifting one or both of the reference and test beams.

  1. Optimisation of phenolic extraction from Averrhoa carambola pomace by response surface methodology and its microencapsulation by spray and freeze drying.

    PubMed

    Saikia, Sangeeta; Mahnot, Nikhil Kumar; Mahanta, Charu Lata

    2015-03-15

    Optimised of the extraction of polyphenol from star fruit (Averrhoa carambola) pomace using response surface methodology was carried out. Two variables viz. temperature (°C) and ethanol concentration (%) with 5 levels (-1.414, -1, 0, +1 and +1.414) were used to design the optimisation model using central composite rotatable design where, -1.414 and +1.414 refer to axial values, -1 and +1 mean factorial points and 0 refers to centre point of the design. The two variables, temperature of 40°C and ethanol concentration of 65% were the optimised conditions for the response variables of total phenolic content, ferric reducing antioxidant capacity and 2,2-diphenyl-1-picrylhydrazyl scavenging activity. The reverse phase-high pressure liquid chromatography chromatogram of the polyphenol extract showed eight phenolic acids and ascorbic acid. The extract was then encapsulated with maltodextrin (⩽ DE 20) by spray and freeze drying methods at three different concentrations. Highest encapsulating efficiency was obtained in freeze dried encapsulates (78-97%). The obtained optimised model could be used for polyphenol extraction from star fruit pomace and microencapsulates can be incorporated in different food systems to enhance their antioxidant property. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Metonymy and Reference-Point Errors in Novice Programming

    ERIC Educational Resources Information Center

    Miller, Craig S.

    2014-01-01

    When learning to program, students often mistakenly refer to an element that is structurally related to the element that they intend to reference. For example, they may indicate the attribute of an object when their intention is to reference the whole object. This paper examines these reference-point errors through the context of metonymy.…

  3. Systems and methods that generate height map models for efficient three dimensional reconstruction from depth information

    DOEpatents

    Frahm, Jan-Michael; Pollefeys, Marc Andre Leon; Gallup, David Robert

    2015-12-08

    Methods of generating a three dimensional representation of an object in a reference plane from a depth map including distances from a reference point to pixels in an image of the object taken from a reference point. Weights are assigned to respective voxels in a three dimensional grid along rays extending from the reference point through the pixels in the image based on the distances in the depth map from the reference point to the respective pixels, and a height map including an array of height values in the reference plane is formed based on the assigned weights. An n-layer height map may be constructed by generating a probabilistic occupancy grid for the voxels and forming an n-dimensional height map comprising an array of layer height values in the reference plane based on the probabilistic occupancy grid.

  4. Genetics Home Reference: central core disease

    MedlinePlus

    ... Twitter Home Health Conditions Central core disease Central core disease Printable PDF Open All Close All Enable ... to view the expand/collapse boxes. Description Central core disease is a disorder that affects muscles used ...

  5. Unsteady steady-states: Central causes of unintentional force drift

    PubMed Central

    Ambike, Satyajit; Mattos, Daniela; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2016-01-01

    We applied the theory of synergies to analyze the processes that lead to unintentional decline in isometric fingertip force when visual feedback of the produced force is removed. We tracked the changes in hypothetical control variables involved in single fingertip force production based on the equilibrium-point hypothesis, namely, the fingertip referent coordinate (RFT) and its apparent stiffness (CFT). The system's state is defined by a point in the {RFT; CFT} space. We tested the hypothesis that, after visual feedback removal, this point (1) moves along directions leading to drop in the output fingertip force, and (2) has even greater motion along directions that leaves the force unchanged. Subjects produced a prescribed fingertip force using visual feedback, and attempted to maintain this force for 15 s after the feedback was removed. We used the “inverse piano” apparatus to apply small and smooth positional perturbations to fingers at various times after visual feedback removal. The time courses of RFT and CFT showed that force drop was mostly due to a drift in RFT towards the actual fingertip position. Three analysis techniques, namely, hyperbolic regression, surrogate data analysis, and computation of motor-equivalent and non-motor-equivalent motions, suggested strong co-variation in RFT and CFT stabilizing the force magnitude. Finally, the changes in the two hypothetical control variables {RFT; CFT} relative to their average trends also displayed covariation. On the whole the findings suggest that unintentional force drop is associated with (a) a slow drift of the referent coordinate that pulls the system towards a low-energy state, and (b) a faster synergic motion of RFT and CFT that tends to stabilize the output fingertip force about the slowly-drifting equilibrium point. PMID:27540726

  6. Unsteady steady-states: central causes of unintentional force drift.

    PubMed

    Ambike, Satyajit; Mattos, Daniela; Zatsiorsky, Vladimir M; Latash, Mark L

    2016-12-01

    We applied the theory of synergies to analyze the processes that lead to unintentional decline in isometric fingertip force when visual feedback of the produced force is removed. We tracked the changes in hypothetical control variables involved in single fingertip force production based on the equilibrium-point hypothesis, namely the fingertip referent coordinate (R FT ) and its apparent stiffness (C FT ). The system's state is defined by a point in the {R FT ; C FT } space. We tested the hypothesis that, after visual feedback removal, this point (1) moves along directions leading to drop in the output fingertip force, and (2) has even greater motion along directions that leaves the force unchanged. Subjects produced a prescribed fingertip force using visual feedback and attempted to maintain this force for 15 s after the feedback was removed. We used the "inverse piano" apparatus to apply small and smooth positional perturbations to fingers at various times after visual feedback removal. The time courses of R FT and C FT showed that force drop was mostly due to a drift in R FT toward the actual fingertip position. Three analysis techniques, namely hyperbolic regression, surrogate data analysis, and computation of motor-equivalent and non-motor-equivalent motions, suggested strong covariation in R FT and C FT stabilizing the force magnitude. Finally, the changes in the two hypothetical control variables {R FT ; C FT } relative to their average trends also displayed covariation. On the whole, the findings suggest that unintentional force drop is associated with (a) a slow drift of the referent coordinate that pulls the system toward a low-energy state and (b) a faster synergic motion of R FT and C FT that tends to stabilize the output fingertip force about the slowly drifting equilibrium point.

  7. Monte Carlo based toy model for fission process

    NASA Astrophysics Data System (ADS)

    Kurniadi, R.; Waris, A.; Viridi, S.

    2014-09-01

    There are many models and calculation techniques to obtain visible image of fission yield process. In particular, fission yield can be calculated by using two calculations approach, namely macroscopic approach and microscopic approach. This work proposes another calculation approach in which the nucleus is treated as a toy model. Hence, the fission process does not represent real fission process in nature completely. The toy model is formed by Gaussian distribution of random number that randomizes distance likesthe distance between particle and central point. The scission process is started by smashing compound nucleus central point into two parts that are left central and right central points. These three points have different Gaussian distribution parameters such as mean (μCN, μL, μR), and standard deviation (σCN, σL, σR). By overlaying of three distributions, the number of particles (NL, NR) that are trapped by central points can be obtained. This process is iterated until (NL, NR) become constant numbers. Smashing process is repeated by changing σL and σR, randomly.

  8. The Then and Now of Reference Conditions in Streams of the Central Plains

    NASA Astrophysics Data System (ADS)

    Huggins, D.; Angelo, R.; Baker, D. S.; Welker, G.

    2005-05-01

    Models of contemporary and pre-settlement reference conditions were constructed for streams that once drained the tallgrass prairies of Iowa, Nebraska, Kansas and Missouri (e.g. Western Corn Belt Plains ecoregion), and for streams within the heart of the mixed grass prairie (e.g. Southwestern Tablelands ecoregion). Data on watershed, habitat, chemistry and biology compiled for existing reference streams (least or minimally impacted systems) were used to characterize contemporary reference conditions. Contemporary reference conditions within these two prairie regions are contrasted against hypothetical pre-settlement conditions using information from the best streams (upper 25%) of the current reference population, historical accounts, museum records, natural heritage programs, Public Land Survey and current remote sensing data. Similar comparisons were made between historical and current reference conditions for the Southwestern Tablelands located in central Kansas and Oklahoma. Much of this region remains in mixed grass prairie; has limited hydrological alterations (e.g. impoundments, dewatering) and low human and livestock densities. Within the tablelands these factors have preserved reference conditions that resemble historic conditions. Qualitative and quantitative comparisons indicate that many regions within the Central Plains require caution when using "least disturbed" reference streams and conditions to identify regional biological integrity goals relative to the Clean Water Act.

  9. Summary Diagrams for Coupled Hydrodynamic-Ecosystem Model Skill Assessment

    DTIC Science & Technology

    2009-01-01

    reference point have the smallest unbiased RMSD value (Fig. 3). It would appear that the cluster of model points closest to the reference point may...total RMSD values. This is particularly the case for phyto- plankton absorption (Fig. 3B) where the cluster of points closest to the reference...pattern statistics and the bias (difference of mean values) each magnitude of the total Root-Mean-Square Difference ( RMSD ). An alternative skill score and

  10. Decoding Facial Esthetics to Recreate an Esthetic Hairline: A Method Which Includes Forehead Curvature.

    PubMed

    Garg, Anil K; Garg, Seema

    2017-01-01

    The evidence suggests that our perception of physical beauty is based on how closely the features of one's face reflect phi (the golden ratio) in their proportions. By that extension, it must certainly be possible to use a mathematical parameter to design an anterior hairline in all faces. To establish a user-friendly method to design an anterior hairline in cases of male pattern alopecia. We need a flexible measuring tape and skin marker. A reference point A (glabella) is taken in between eyebrows. Mark point E, near the lateral canthus, 8 cm horizontal on either side from the central point A. A mid-frontal point (point B) is marked 8 cm from point A on the forehead in a mid-vertical plane. The frontotemporal points (C and C') are marked on the frontotemporal area, 8 cm in a horizontal plane from point B and 8 cm in a vertical plane from point E. The temporal peak points (D and D') are marked on the line joining the frontotemporal point C to the lateral canthus point E, slightly more than halfway toward lateral canthus, usually 5 cm from the frontotemporal point C. This line makes an anterior border of the temporal triangle. We have conducted a study with 431 cases of male pattern alopecia. The average distance of the mid-frontal point from glabella was 7.9 cm. The patient satisfaction reported was 94.7%. Our method gives a skeletal frame of the anterior hairline with minimal criteria, with no need of visual imagination and experience of the surgeon. It automatically takes care of the curvature of the forehead and is easy to use for a novice surgeon.

  11. A digital microfluidic system for serological immunoassays in remote settings.

    PubMed

    Ng, Alphonsus H C; Fobel, Ryan; Fobel, Christian; Lamanna, Julian; Rackus, Darius G; Summers, Aimee; Dixon, Christopher; Dryden, Michael D M; Lam, Charis; Ho, Man; Mufti, Nooman S; Lee, Victor; Asri, Mohd Afiq Mohd; Sykes, Edward A; Chamberlain, M Dean; Joseph, Rachael; Ope, Maurice; Scobie, Heather M; Knipes, Alaine; Rota, Paul A; Marano, Nina; Chege, Paul M; Njuguna, Mary; Nzunza, Rosemary; Kisangau, Ngina; Kiogora, John; Karuingi, Michael; Burton, John Wagacha; Borus, Peter; Lam, Eugene; Wheeler, Aaron R

    2018-04-25

    Serosurveys are useful for assessing population susceptibility to vaccine-preventable disease outbreaks. Although at-risk populations in remote areas could benefit from this type of information, they face several logistical barriers to implementation, such as lack of access to centralized laboratories, cold storage, and transport of samples. We describe a potential solution: a compact and portable, field-deployable, point-of-care system relying on digital microfluidics that can rapidly test a small volume of capillary blood for disease-specific antibodies. This system uses inexpensive, inkjet-printed digital microfluidic cartridges together with an integrated instrument to perform enzyme-linked immunosorbent assays (ELISAs). We performed a field validation of the system's analytical performance at Kakuma refugee camp, a remote setting in northwestern Kenya, where we tested children aged 9 to 59 months and caregivers for measles and rubella immunoglobulin G (IgG). The IgG assays were determined to have sensitivities of 86% [95% confidence interval (CI), 79 to 91% (measles)] and 81% [95% CI, 73 to 88% (rubella)] and specificities of 80% [95% CI, 49 to 94% (measles)] and 91% [95% CI, 76 to 97% (rubella)] (measles, n = 140; rubella, n = 135) compared with reference tests (measles IgG and rubella IgG ELISAs from Siemens Enzygnost) conducted in a centralized laboratory. These results demonstrate a potential role for this point-of-care system in global serological surveillance, particularly in remote areas with limited access to centralized laboratories. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  12. The Influence of the Tri-reference Points on Fairness and Satisfaction Perception

    PubMed Central

    Zhao, Lei; Ye, Junhui; Wu, Xuexian; Hu, Fengpei

    2018-01-01

    We examined the influence of three reference points (minimum requirements [MR], the status quo [SQ], and goal [G]) proposed by the tri-reference point (TRP) theory on fairness and satisfaction perceptions of pay in three laboratory experiments. To test the effects, we manipulated these three reference points both implicitly (Experiment 1) and explicitly (Experiments 2 and 3). We also provided the information of the salary offered to a peer person that was lower than, equal to, or higher than the salary offer to the participant. As hypothesized, the results demonstrated the important role of these reference points in judging the fairness of and satisfaction with pay when they were explicitly set (an interaction between reference points and social comparison in Experiments 2 and 3, but not in Experiment 1). Participants altered their judgments when the salary was in different regions. When the salary was below MR, participants perceived very low fairness and satisfaction, even when the offer was equal to/exceeded others. When the salary was above G, participants perceived much higher fairness and satisfaction, even with disadvantageous inequality. Participants were more impacted when they were explicitly instructed of the reference points (Experiments 2 and 3) than when they were not (Experiment 1). Moreover, MR appeared to be the most important, followed by G. A Salary below MR was judged as very unacceptable, with very low fairness and satisfaction ratings. PMID:29515503

  13. Library and Information Networks: Centralization and Decentralization.

    ERIC Educational Resources Information Center

    Segal, JoAnn S.

    1988-01-01

    Describes the development of centralized library networks and the current factors that make library sharing on a smaller scale feasible. The discussion covers the need to decide the level at which library cooperation should occur and the possibility of linking via the Open System Interface Reference Model. (37 references) (CLB)

  14. Young Children Follow Pointing over Words in Interpreting Acts of Reference

    ERIC Educational Resources Information Center

    Grassmann, Susanne; Tomasello, Michael

    2010-01-01

    Adults refer young children's attention to things in two basic ways: through the use of pointing (and other deictic gestures) and words (and other linguistic conventions). In the current studies, we referred young children (2- and 4-year-olds) to things in conflicting ways, that is, by pointing to one object while indicating linguistically (in…

  15. Performance comparison of different thermodynamic cycles for an innovative central receiver solar power plant

    NASA Astrophysics Data System (ADS)

    Reyes-Belmonte, Miguel A.; Sebastián, Andrés; González-Aguilar, José; Romero, Manuel

    2017-06-01

    The potential of using different thermodynamic cycles coupled to a solar tower central receiver that uses a novel heat transfer fluid is analyzed. The new fluid, named as DPS, is a dense suspension of solid particles aerated through a tubular receiver used to convert concentrated solar energy into thermal power. This novel fluid allows reaching high temperatures at the solar receiver what opens a wide range of possibilities for power cycle selection. This work has been focused into the assessment of power plant performance using conventional, but optimized cycles but also novel thermodynamic concepts. Cases studied are ranging from subcritical steam Rankine cycle; open regenerative Brayton air configurations at medium and high temperature; combined cycle; closed regenerative Brayton helium scheme and closed recompression supercritical carbon dioxide Brayton cycle. Power cycle diagrams and working conditions for design point are compared amongst the studied cases for a common reference thermal power of 57 MWth reaching the central cavity receiver. It has been found that Brayton air cycle working at high temperature or using supercritical carbon dioxide are the most promising solutions in terms of efficiency conversion for the power block of future generation by means of concentrated solar power plants.

  16. Inertial instabilities in a mixing-separating microfluidic device

    NASA Astrophysics Data System (ADS)

    Domingues, Allysson; Poole, Robert; Dennis, David

    2017-11-01

    Combining and separating fluids has many industrial and biomedical applications. This numerical and experimental study explores inertial instabilities in a so-called mixing-separating cell micro-geometry which could potentiality be used to enhance mixing. Our microfluidic mixing-separating cell consists of two straight square parallel channels with flow from opposite directions with a central gap that allows the streams to interact, mix or remain separate (often referred to as the `H' geometry). A stagnation point is generated at the centre of symmetry due to the two opposed inlets and outlets. Under creeping flow conditions (Reynolds number [ Re 0 ]) the flow is steady, two-dimensional and produces a sharp symmetric boundary between fluids stream entering the geometry from opposite directions. For Re > 30 , an inertial instability appears which leads to the generation of a central vortex and the breaking of symmetry, although the flow remains steady. As Re increases the central vortex divides into two vortices. Our experimental and numerical investigations both show the same phenomena. The results suggest that the effect observed can be exploited to enhance mixing in biomedical or other applications. Work supported by CNPq Grant 203195/2014-0.

  17. Assessment of the potential of solar thermal small power systems in small utilities

    NASA Technical Reports Server (NTRS)

    Steitz, P.; Mayo, L. G.; Perkins, S. P., Jr.

    1978-01-01

    The potential economic benefit of small solar thermal electric power systems to small municipal and rural electric utilities is assessed. Five different solar thermal small power system configurations were considered in three different solar thermal technologies. The configurations included: (1) 1 MW, 2 MW, and 10 MW parabolic dish concentrators with a 15 kW heat engine mounted at the focal point of each dish, these systems utilized advanced battery energy storage; (2) a 10 MW system with variable slat concentrators and central steam Rankine energy conversion, this system utilized sensible thermal energy storage; and (3) a 50 MW central receiver system consisting of a field of heliostats concentrating energy on a tower-mounted receiver and a central steam Rankine conversion system, this system also utilized sensible thermal storage. The results are summarized in terms of break-even capital costs. The break-even capital cost was defined as the solar thermal plant capital cost which would have to be achieved in order for the solar thermal plants to penetrate 10 percent of the reference small utility generation mix by the year 2000. The calculated break-even capital costs are presented.

  18. Apparatus and method for mapping an area of interest

    DOEpatents

    Staab, Torsten A. Cohen, Daniel L.; Feller, Samuel [Fairfax, VA

    2009-12-01

    An apparatus and method are provided for mapping an area of interest using polar coordinates or Cartesian coordinates. The apparatus includes a range finder, an azimuth angle measuring device to provide a heading and an inclinometer to provide an angle of inclination of the range finder as it relates to primary reference points and points of interest. A computer is provided to receive signals from the range finder, inclinometer and azimuth angle measurer to record location data and calculate relative locations between one or more points of interest and one or more primary reference points. The method includes mapping of an area of interest to locate points of interest relative to one or more primary reference points and to store the information in the desired manner. The device may optionally also include an illuminator which can be utilized to paint the area of interest to indicate both points of interest and primary points of reference during and/or after data acquisition.

  19. The place of probability in Hilbert's axiomatization of physics, ca. 1900-1928

    NASA Astrophysics Data System (ADS)

    Verburgt, Lukas M.

    2016-02-01

    Although it has become a common place to refer to the 'sixth problem' of Hilbert's (1900) Paris lecture as the starting point for modern axiomatized probability theory, his own views on probability have received comparatively little explicit attention. The central aim of this paper is to provide a detailed account of this topic in light of the central observation that the development of Hilbert's project of the axiomatization of physics went hand-in-hand with a redefinition of the status of probability theory and the meaning of probability. Where Hilbert first regarded the theory as a mathematizable physical discipline and later approached it as a 'vague' mathematical application in physics, he eventually understood probability, first, as a feature of human thought and, then, as an implicitly defined concept without a fixed physical interpretation. It thus becomes possible to suggest that Hilbert came to question, from the early 1920s on, the very possibility of achieving the goal of the axiomatization of probability as described in the 'sixth problem' of 1900.

  20. Surgical management of insertional calcific achilles tendinosis with a central tendon splitting approach.

    PubMed

    Johnson, Keith W; Zalavras, Charalampos; Thordarson, David B

    2006-04-01

    Insertional calcific Achilles tendinosis is a painful, frequently disabling condition. Numerous operative approaches for this problem have been described. This study evaluated the outcome of a central tendon splitting approach. Twenty-two patients were evaluated after a central tendon splitting approach for persistent insertional calcific Achilles tendinosis. Followup averaged 34 (11 to 64) months. Suture anchors were routinely used to augment the tendon insertion after debridement. An American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, shoewear comfort, and return to work were evaluated. A paired t-test was used to evaluate the results. Pain significantly improved from 7 points preoperatively to 33 points postoperatively (p < 0.001). Function improved significantly from 36 points to 46 points (p < 0.001). The ankle-hindfoot score improved from 53 points to 89 points (p < 0.001). Age older or younger than 50 years did not affect outcome. A central tendon splitting approach yielded good relief of pain with improved function, shoewear, and ability to work without painful postoperative scars.

  1. Evaluation of major heat waves' mechanisms in EURO-CORDEX RCMs over Central Europe

    NASA Astrophysics Data System (ADS)

    Lhotka, Ondřej; Kyselý, Jan; Plavcová, Eva

    2018-06-01

    The main aim of the study is to evaluate the capability of EURO-CORDEX regional climate models (RCMs) to simulate major heat waves in Central Europe and their associated meteorological factors. Three reference major heat waves (1994, 2006, and 2015) were identified in the E-OBS gridded data set, based on their temperature characteristics, length and spatial extent. Atmospheric circulation, precipitation, net shortwave radiation, and evaporative fraction anomalies during these events were assessed using the ERA-Interim reanalysis. The analogous major heat waves and their links to the aforementioned factors were analysed in an ensemble of EURO-CORDEX RCMs driven by various global climate models in the 1970-2016 period. All three reference major heat waves were associated with favourable circulation conditions, precipitation deficit, reduced evaporative fraction and increased net shortwave radiation. This joint contribution of large-scale circulation and land-atmosphere interactions is simulated with difficulties in majority of the RCMs, which affects the magnitude of modelled major heat waves. In some cases, the seemingly good reproduction of major heat waves' magnitude is erroneously achieved through extremely favourable circulation conditions compensated by a substantial surplus of soil moisture or vice versa. These findings point to different driving mechanisms of major heat waves in some RCMs compared to observations, which should be taken into account when analysing and interpreting future projections of these events.

  2. Factors influencing superimposition error of 3D cephalometric landmarks by plane orientation method using 4 reference points: 4 point superimposition error regression model.

    PubMed

    Hwang, Jae Joon; Kim, Kee-Deog; Park, Hyok; Park, Chang Seo; Jeong, Ho-Gul

    2014-01-01

    Superimposition has been used as a method to evaluate the changes of orthodontic or orthopedic treatment in the dental field. With the introduction of cone beam CT (CBCT), evaluating 3 dimensional changes after treatment became possible by superimposition. 4 point plane orientation is one of the simplest ways to achieve superimposition of 3 dimensional images. To find factors influencing superimposition error of cephalometric landmarks by 4 point plane orientation method and to evaluate the reproducibility of cephalometric landmarks for analyzing superimposition error, 20 patients were analyzed who had normal skeletal and occlusal relationship and took CBCT for diagnosis of temporomandibular disorder. The nasion, sella turcica, basion and midpoint between the left and the right most posterior point of the lesser wing of sphenoidal bone were used to define a three-dimensional (3D) anatomical reference co-ordinate system. Another 15 reference cephalometric points were also determined three times in the same image. Reorientation error of each landmark could be explained substantially (23%) by linear regression model, which consists of 3 factors describing position of each landmark towards reference axes and locating error. 4 point plane orientation system may produce an amount of reorientation error that may vary according to the perpendicular distance between the landmark and the x-axis; the reorientation error also increases as the locating error and shift of reference axes viewed from each landmark increases. Therefore, in order to reduce the reorientation error, accuracy of all landmarks including the reference points is important. Construction of the regression model using reference points of greater precision is required for the clinical application of this model.

  3. A Tri-Reference Point Theory of Decision Making under Risk

    ERIC Educational Resources Information Center

    Wang, X. T.; Johnson, Joseph G.

    2012-01-01

    The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x greater than or equal to G), gain (SQ less than x less than G), loss (MR…

  4. 16 CFR Figure 5 to Subpart A of... - Zero Reference Point Related to Detecting Plane

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Zero Reference Point Related to Detecting Plane 5 Figure 5 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 5 Figure 5 to Subpart A of Part 1209—Zero Reference Point Related to Detecting...

  5. 16 CFR Figure 5 to Subpart A of... - Zero Reference Point Related to Detecting Plane

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Zero Reference Point Related to Detecting Plane 5 Figure 5 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 5 Figure 5 to Subpart A of Part 1209—Zero Reference Point Related to Detecting...

  6. 16 CFR Figure 5 to Subpart A of... - Zero Reference Point Related to Detecting Plane

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Zero Reference Point Related to Detecting Plane 5 Figure 5 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION.... 1209, Subpt. A, Fig. 5 Figure 5 to Subpart A of Part 1209—Zero Reference Point Related to Detecting...

  7. 15. Credit JTL: Detail, oblique view of central panel point ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. Credit JTL: Detail, oblique view of central panel point connection at top chord; note recess in chord bar to right of joint, and missing third (central) vertical tie rod - Reading-Halls Station Bridge, U.S. Route 220, spanning railroad near Halls Station, Muncy, Lycoming County, PA

  8. A tri-reference point theory of decision making under risk.

    PubMed

    Wang, X T; Johnson, Joseph G

    2012-11-01

    The tri-reference point (TRP) theory takes into account minimum requirements (MR), the status quo (SQ), and goals (G) in decision making under risk. The 3 reference points demarcate risky outcomes and risk perception into 4 functional regions: success (expected value of x ≥ G), gain (SQ < × < G), loss (MR ≤ x < SQ), and failure (x < MR). The psychological impact of achieving or failing to achieve these reference points is rank ordered as MR > G > SQ. We present TRP assumptions and value functions and a mathematical formalization of the theory. We conducted empirical tests of crucial TRP predictions using both explicit and implicit reference points. We show that decision makers consider both G and MR and give greater weight to MR than G, indicating failure aversion (i.e., the disutility of a failure is greater than the utility of a success in the same task) in addition to loss aversion (i.e., the disutility of a loss is greater than the utility of the same amount of gain). Captured by a double-S shaped value function with 3 inflection points, risk preferences switched between risk seeking and risk aversion when the distribution of a gamble straddled a different reference point. The existence of MR (not G) significantly shifted choice preference toward risk aversion even when the outcome distribution of a gamble was well above the MR. Single reference point based models such as prospect theory cannot consistently account for these findings. The TRP theory provides simple guidelines for evaluating risky choices for individuals and organizational management. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  9. Accuracy of body mass index for age to diagnose obesity in Mexican schoolchildren.

    PubMed

    Mendoza Pablo, Pedro A; Valdés, Jesús; Ortiz-Hernández, Luis

    2015-06-01

    To compare the accuracy of three BMI-forage references (World Health Organization reference, WHO; the updated International Obesity Task Force reference, IOTF; and Centers for Disease Control and Prevention (CDC) growth charts) to diagnose obesity in Mexican children. A convenience sample of Mexican schoolchildren (n = 218) was assessed. The gold standard was the percentage of body fat estimated by deuterium dilution technique. Sensitivity and specificity of the classical cutoff point of BMI-for-age to identify obesity (i.e. > 2.00 standard deviation, SD) were estimated. The accuracy (i.e. area under the curve, AUC) of three BMI-for-age references for the diagnosis of obesity was estimated with the receiver operating characteristic (ROC) curves method. The optimal cutoff point (OCP) was determined. The cutoff points to identify obesity had low (WHO reference: 57.6%, CDC: 53.5%) to very low (IOTF reference: 40.4%) sensitivities, but adequate specificities (91.6%, 95.0%, and, 97.5%, respectively). The AUC of the three references were adequate (0.89). For the IOTF reference, the AUC was lower among the older children. The OCP for the CDC reference (1.24 SD) was lower than the OCP for WHO (1.53 SD) and IOTF charts (1.47 SD). The classical cutoff point for obesity has low sensitivity--especially for the IOTF reference. The accuracy of the three references was similar. However, to obtain comparable diagnosis of obesity different cutoff points should be used depending of the reference. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  10. Image processing of HCMM-satellite thermal images for superposition with other satellite imagery and topographic and thematic maps. [Upper Rhine River Valley and surrounding highlands Switzerland, Germany, and France

    NASA Technical Reports Server (NTRS)

    Gossmann, H.; Haberaecker, P. (Principal Investigator)

    1980-01-01

    The southwestern part of Central Europe between Basal and Frankfurt was used in a study to determine the accuracy with which a regionally bounded HCMM scene could be rectified with respect to a preassigned coordinate system. The scale to which excerpts from HCMM data can be sensibly enlarged and the question of how large natural structures must be in order to be identified in a satellite thermal image with the given resolution were also examined. Relief and forest and population distribution maps and a land use map derived from LANDSAT data were digitalized and adapted to a common reference system and then combined in a single multichannel data system. The control points for geometrical rectification were determined using the coordinates of the reference system. The multichannel scene was evaluated in several different manners such as the correlation of surface temperature and relief, surface temperature and land use, or surface temperature and built up areas.

  11. Coordinate interferometric system for measuring the position of a sample with infrared telecom laser diode

    NASA Astrophysics Data System (ADS)

    Holá, Miroslava; Lazar, Josef; Čížek, Martin; Hucl, Václav; Řeřucha, Šimon; Číp, Ondřej

    2016-11-01

    We report on a design of an interferometric position measuring system for control of a sample stage in an e-beam writer with reproducibility of the position on nanometer level and resolution below nanometer. We introduced differential configuration of the interferometer where the position is measured with respect to a central reference point to eliminate deformations caused by thermal and pressure effects on the vacuum chamber. The reference is here the electron gun of the writer. The interferometer is designed to operate at infrared, telecommunication wavelength due to the risk of interference of stray light with sensitive photodetectors in the chamber. The laser source is here a narrow-linewidth DFB laser diode with electronics of our own design offering precision and stability of temperature and current, low-noise, protection from rf interference, and high-frequency modulation. Detection of the interferometric signal relies on a novel derivative technique utilizing hf frequency modulation and phase-sensitive detection.

  12. The EBI SRS server-new features.

    PubMed

    Zdobnov, Evgeny M; Lopez, Rodrigo; Apweiler, Rolf; Etzold, Thure

    2002-08-01

    Here we report on recent developments at the EBI SRS server (http://srs.ebi.ac.uk). SRS has become an integration system for both data retrieval and sequence analysis applications. The EBI SRS server is a primary gateway to major databases in the field of molecular biology produced and supported at EBI as well as European public access point to the MEDLINE database provided by US National Library of Medicine (NLM). It is a reference server for latest developments in data and application integration. The new additions include: concept of virtual databases, integration of XML databases like the Integrated Resource of Protein Domains and Functional Sites (InterPro), Gene Ontology (GO), MEDLINE, Metabolic pathways, etc., user friendly data representation in 'Nice views', SRSQuickSearch bookmarklets. SRS6 is a licensed product of LION Bioscience AG freely available for academics. The EBI SRS server (http://srs.ebi.ac.uk) is a free central resource for molecular biology data as well as a reference server for the latest developments in data integration.

  13. A new methodology for automatic detection of reference points in 3D cephalometry: A pilot study.

    PubMed

    Ed-Dhahraouy, Mohammed; Riri, Hicham; Ezzahmouly, Manal; Bourzgui, Farid; El Moutaoukkil, Abdelmajid

    2018-04-05

    The aim of this study was to develop a new method for an automatic detection of reference points in 3D cephalometry to overcome the limits of 2D cephalometric analyses. A specific application was designed using the C++ language for automatic and manual identification of 21 (reference) points on the craniofacial structures. Our algorithm is based on the implementation of an anatomical and geometrical network adapted to the craniofacial structure. This network was constructed based on the anatomical knowledge of the 3D cephalometric (reference) points. The proposed algorithm was tested on five CBCT images. The proposed approach for the automatic 3D cephalometric identification was able to detect 21 points with a mean error of 2.32mm. In this pilot study, we propose an automated methodology for the identification of the 3D cephalometric (reference) points. A larger sample will be implemented in the future to assess the method validity and reliability. Copyright © 2018 CEO. Published by Elsevier Masson SAS. All rights reserved.

  14. Help Central: Creating a Help Desk and Knowledge Portal in SharePoint

    ERIC Educational Resources Information Center

    Ennis, Lisa A.; Tims, Randy S.

    2012-01-01

    This article discusses the authors' implementation of Help Central, a site within the Lister Hill Library Collection on the University of Alabama-Birmingham's SharePoint server. Initially, Help Central was designed to address the inadequacies in the library's old, static HTML web-based support system, including haphazard issue reporting by staff…

  15. Identification of Distant Metastatic Disease in Uterine Cervical and Endometrial Cancers with FDG PET/CT: Analysis from the ACRIN 6671/GOG 0233 Multicenter Trial.

    PubMed

    Gee, Michael S; Atri, Mostafa; Bandos, Andriy I; Mannel, Robert S; Gold, Michael A; Lee, Susanna I

    2018-04-01

    Purpose To assess the accuracy of staging positron emission tomography (PET)/computed tomography (CT) in detecting distant metastasis in patients with local-regionally advanced cervical and high-risk endometrial cancer in the clinical trial by the American College of Radiology Imaging Network (ACRIN) and the Gynecology Oncology Group (GOG) (ACRIN 6671/GOG 0233) and to compare central and institutional reader performance. Materials and Methods In this prospective multicenter trial, PET/CT and clinical data were reviewed for patients enrolled in ACRIN 6671/GOG 0233. Two central readers, blinded to site read and reference standard, reviewed PET/CT images for distant metastasis. Central review was then compared with institutional point-of-care interpretation. Reference standard was pathologic and imaging follow-up. Test performance for central and site reviews of PET/CT images was calculated and receiver operating characteristic analysis was performed. Generalized estimating equations and nonparametric bootstrap procedure for clustered data were used to assess statistical significance. Results There were 153 patients with cervical cancer and 203 patients with endometrial cancer enrolled at 28 sites. Overall prevalence of distant metastasis was 13.7% (21 of 153) for cervical cancer and 11.8% (24 of 203) for endometrial cancer. Central reader PET/CT interpretation demonstrated sensitivity, specificity, positive predictive value (PPV), and negative predictive value of 54.8%, 97.7%, 79.3%, and 93.1% for cervical cancer metastasis versus 64.6%, 98.6%, 86.1%, and 95.4% for endometrial cancer, respectively. By comparison, local institutional review demonstrated sensitivity, specificity, PPV, and negative predictive value of 47.6%, 93.9%, 55.6%, and 91.9% for cervical cancer metastasis and 66.7%, 93.9%, 59.3%, and 95.5% for endometrial cancer, respectively. For central readers, the specificity and PPV of PET/CT detection of cervical and endometrial cancer metastases were all significantly higher compared with that of local institutional review (P < .05). Central reader area under the receiver operating characteristic curve (AUC) values were 0.78 and 0.89 for cervical and endometrial cancer, respectively; these were not significantly different from local institutional AUC values (0.75 and 0.84, respectively; P > .05 for both). Conclusion FDG PET/CT demonstrates high specificity and PPV for detecting distant metastasis in cervical and endometrial cancer and should be included in the staging evaluation. Blinded central review of imaging provides improved specificity and PPV for the detection of metastases and should be considered for future oncologic imaging clinical trials. © RSNA, 2017.

  16. Semantics, Cross-Cultural Style

    ERIC Educational Resources Information Center

    Machery, Edouard; Mallon, Ron; Nichols, Shaun; Stich, Stephen P.

    2004-01-01

    Theories of reference have been central to analytic philosophy, and two views, "the descriptivist view of reference" and "the causal-historical view of reference," have dominated the field. In this research tradition, theories of reference are assessed by consulting one's intuitions about the reference of terms in hypothetical situations. However,…

  17. 49 CFR 571.210 - Standard No. 210; Seat belt assembly anchorages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... reference point, shall extend forward from that contact point at an angle with the horizontal of not less... torso belt first contacts the uppermost torso belt anchorage.Seat belt anchorage means any component... line from the seating reference point to the nearest contact point of the belt with the anchorage shall...

  18. Present-Day Kinematics of the Central Mediterranean Plate Boundary Region from Large GPS Network Analysis Using the Ambizap Algorithm

    NASA Astrophysics Data System (ADS)

    D'Anastasio, E.; D'Agostino, N.; Avallone, A.; Blewitt, G.

    2008-12-01

    The large, recent increase of continuous GPS (CGPS) stations in the Central Mediterranean plate boundary zone offers the opportunity to study in detail the present-day kinematics of this actively deforming region. CGPS data from scientific and commercial networks in the Italian region is now available from more than 350 stations, including more than 130 from the RING network deployed by the Istituto Nazionale di Geofisica e Vulcanologia. The RING stations all have high quality GPS monuments and are co- located with broadband or very broadband seismometers and strong motion sensors. The analysis presented here also uses far-field data to provide reference frame control, bringing the total to over 580 CGPS stations. GPS ambiguity resolution of such a large amount of data presents a serious challenge in terms of processing time. Many scientific GPS data processing software packages address this problem by dividing the network into several clusters. In contrast, this analysis uses the new Ambizap GPS processing algorithm (Blewitt, 2008) to obtain unique, self-consistent daily ambiguity-fixed solutions for the entire network. Ambizap allows for a rapid and multiple reanalysis of large regional networks such the one presented in this work. Tests show that Ambizap reproduces solutions from time-prohibitive full-network ambiguity resolution to much less than 1 mm. Single station GPS data are first processed with the GIPSY-OASIS II software by the precise point positioning (PPP) strategy (Zumberge et al., 1997) using JPL products from ftp://sideshow.jpl.nasa.gov. Integer ambiguity resolution is then applied using Ambizap. The resulting daily solutions are aligned to the ITRF2005 reference frame. Then, using the CATS software (Williams, 2007), time series are cleaned to remove outliers and are analyzed for their noise properties, linear velocities, periodic signals and antenna jumps. Stable plate reference frames are realized by minimizing the horizontal velocities at more than 70 and 20 sites on the Eurasia and Nubia plates, respectively. The daily RMS scatter for the east coordinates (derived from PPP) in this frame is typically in the range 2-4 mm before applying Ambizap, and 1-2 mm after applying Ambizap. The solutions are then evaluated with regard to the numerous scientific motivations behind this project, ranging from the definition of strain distribution and microplate kinematics within the plate boundary, to the evaluation of tectonic strain accumulation on active faults. References: Blewitt, G. (2008), Fixed-point theorems of GPS carrier phase ambiguity resolution and their application to massive network processing: 'Ambizap', J. Geophys. Res., doi:10.1029/2008JB005736, in press. Williams, S.D.P. (2007), CATS: GPS coordinate time series analysis software, GPS solut., doi:10.1007/s10291-007-0086-4 Zumberge, J. F., M. B. Heflin, D. C. Jefferson, M. M. Watkins, and F. H. Webb (1997), Precise point positioning for the efficient and robust analysis of GPS data from large networks, J. Geophys. Res., 102, 5005-501

  19. Handwriting assessment of Franco-Quebec primary school-age students

    PubMed

    Couture, Mélanie; Morin, Marie-France; Coallier, Mélissa; Lavigne, Audrey; Archambault, Patricia; Bolduc, Émilie; Chartier, Émilie; Liard, Karolane; Jasmin, Emmanuelle

    2016-12-01

    Reasons for referring school-age children to occupational therapy mainly relate to handwriting problems. However, there are no validated tools or reference values for assessing handwriting in francophone children in Canada. This study aimed to adapt and validate the writing tasks described in an English Canadian handwriting assessment protocol and to develop reference values for handwriting speed for francophone children. Three writing tasks from the Handwriting Assessment Protocol-2nd Edition (near-point and far-point copying and dictation) were adapted for Québec French children and administered to 141 Grade 1 ( n = 73) and Grade 2 ( n = 68) students. Reference values for handwriting speed were obtained for near point and far point copying tasks. This adapted protocol and these reference values for speed will improve occupational therapy handwriting assessments for the target population.

  20. The gallium melting-point standard: its role in our temperature measurement system.

    PubMed

    Mangum, B W

    1977-01-01

    The latest internationally-adopted temperature scale, the International Practical Temperature Scale of 1968 (amended edition of 1975), is discussed in some detail and a brief description is given of its evolution. The melting point of high-purity gallium (stated to be at least 99.99999% pure) as a secondary temperature reference point is evaluated. I believe that this melting-point temperature of gallium should be adopted by the various medical professional societies and voluntary standards groups as the reaction temperature for enzyme reference methods in clinical enzymology. Gallium melting-point cells are available at the National Bureau of Standards as Standard Reference Material No. 1968.

  1. Lessons learned from the design of chemical space networks and opportunities for new applications.

    PubMed

    Vogt, Martin; Stumpfe, Dagmar; Maggiora, Gerald M; Bajorath, Jürgen

    2016-03-01

    The concept of chemical space is of fundamental relevance in chemical informatics and computer-aided drug discovery. In a series of articles published in the Journal of Computer-Aided Molecular Design, principles of chemical space design were evaluated, molecular networks proposed as an alternative to conventional coordinate-based chemical reference spaces, and different types of chemical space networks (CSNs) constructed and analyzed. Central to the generation of CSNs was the way in which molecular similarity relationships were assessed and a primary focal point was the network-based representation of biologically relevant chemical space. The design and comparison of CSNs based upon alternative similarity measures can be viewed as an evolutionary path with interesting lessons learned along the way. CSN design has matured to the point that such chemical space representations can be used in practice. In this contribution, highlights from the sequence of CSN design efforts are discussed in context, providing a perspective for future practical applications.

  2. Lessons learned from the design of chemical space networks and opportunities for new applications

    NASA Astrophysics Data System (ADS)

    Vogt, Martin; Stumpfe, Dagmar; Maggiora, Gerald M.; Bajorath, Jürgen

    2016-03-01

    The concept of chemical space is of fundamental relevance in chemical informatics and computer-aided drug discovery. In a series of articles published in the Journal of Computer- Aided Molecular Design, principles of chemical space design were evaluated, molecular networks proposed as an alternative to conventional coordinate-based chemical reference spaces, and different types of chemical space networks (CSNs) constructed and analyzed. Central to the generation of CSNs was the way in which molecular similarity relationships were assessed and a primary focal point was the network-based representation of biologically relevant chemical space. The design and comparison of CSNs based upon alternative similarity measures can be viewed as an evolutionary path with interesting lessons learned along the way. CSN design has matured to the point that such chemical space representations can be used in practice. In this contribution, highlights from the sequence of CSN design efforts are discussed in context, providing a perspective for future practical applications.

  3. Grappling with the Literature of Education Research and Practice

    PubMed Central

    2007-01-01

    The absence of a central database and use of specialized language hinder nonexperts in becoming familiar with the science teaching and learning literature and using it to inform their work. The challenge of locating articles related to a specific question or problem, coupled with the difficulty of comprehending findings based on a variety of different perspectives and practices, can be prohibitively difficult. As I have transitioned from bench to classroom-based research, I have become familiar with how to locate, decipher, and evaluate the education research literature. In this essay, I point out analogies to the literature of science research and practice, and I reference some of the literature that I have found useful in becoming an education researcher. I also introduce a new regular feature, “Current Insights: Recent Research in Science Teaching and Learning,” which is designed to point CBE—Life Sciences Education (CBE-LSE) readers to current articles of interest in life sciences education, as well as more general and noteworthy publications in education research. PMID:18056300

  4. 3D measurement using circular gratings

    NASA Astrophysics Data System (ADS)

    Harding, Kevin

    2013-09-01

    3D measurement using methods of structured light are well known in the industry. Most such systems use some variation of straight lines, either as simple lines or with some form of encoding. This geometry assumes the lines will be projected from one side and viewed from another to generate the profile information. But what about applications where a wide triangulation angle may not be practical, particularly at longer standoff distances. This paper explores the use of circular grating patterns projected from a center point to achieve 3D information. Originally suggested by John Caulfield around 1990, the method had some interesting potential, particularly if combined with alternate means of measurement from traditional triangulation including depth from focus methods. The possible advantages of a central reference point in the projected pattern may offer some different capabilities not as easily attained with a linear grating pattern. This paper will explore the pros and cons of the method and present some examples of possible applications.

  5. Grappling with the literature of education research and practice.

    PubMed

    Dolan, Erin L

    2007-01-01

    The absence of a central database and use of specialized language hinder nonexperts in becoming familiar with the science teaching and learning literature and using it to inform their work. The challenge of locating articles related to a specific question or problem, coupled with the difficulty of comprehending findings based on a variety of different perspectives and practices, can be prohibitively difficult. As I have transitioned from bench to classroom-based research, I have become familiar with how to locate, decipher, and evaluate the education research literature. In this essay, I point out analogies to the literature of science research and practice, and I reference some of the literature that I have found useful in becoming an education researcher. I also introduce a new regular feature, "Current Insights: Recent Research in Science Teaching and Learning," which is designed to point CBE--Life Sciences Education (CBE-LSE) readers to current articles of interest in life sciences education, as well as more general and noteworthy publications in education research.

  6. A U.S. Geological Survey Data Standard (Specifications for representation of geographic point locations for information interchange)

    USGS Publications Warehouse

    ,

    1983-01-01

    This standard establishes uniform formats for geographic point location data. Geographic point location refers to the use of a coordinate system to define the position of a point that may be on, above, or below the Earth's surface. It provides a means for representing these data in digital form for the purpose of interchanging information among data systems and improving clarity and accuracy of interpersonal communications. This document is an expansion and clarification of National Bureau of Standards FIPS PUB 70, issued October 24, 1980. There are minor editorial changes, plus the following additions and modifications: (I) The representation of latitude and longitude using radian measure was added. (2) Alternate 2 for Representation of Hemispheric Information was deleted. (3) Use of the maximum precision for all numerical values was emphasized. The Alternate Representation of Precision was deleted. (4) The length of the zone representation for the State Plane Coordinate System was standardized. (5) The term altitude was substituted for elevation throughout to conform with international usage. (6) Section 3, Specifications for Altitude Data, was expanded and upgraded significantly to the same level of detail as for the horizontal values. (7) A table delineating the coverage of Universal Transverse Mercator zones and the longitudes of the Central Meridians was added and the other tables renumbered. (8) The total length of the representation of point location data at maximum precision was standardized.

  7. Efficacy of the Amsler Grid Test in Evaluating Glaucomatous Central Visual Field Defects.

    PubMed

    Su, Daniel; Greenberg, Andrew; Simonson, Joseph L; Teng, Christopher C; Liebmann, Jeffrey M; Ritch, Robert; Park, Sung Chul

    2016-04-01

    To investigate the efficacy of the Amsler grid test in detecting central visual field (VF) defects in glaucoma. Prospective, cross-sectional study. Patients with glaucoma with reliable Humphrey 10-2 Swedish Interactive Threshold Algorithm standard VF on the date of enrollment or within the previous 3 months. Amsler grid tests were performed for each eye and were considered "abnormal" if there was any perceived scotoma with missing or blurry grid lines within the central 10 degrees ("Amsler grid scotoma"). An abnormal 10-2 VF was defined as ≥3 adjacent points at P < 0.01 with at least 1 point at P < 0.005 in the same hemifield on the pattern deviation plot. Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area were calculated with the 10-2 VF as the clinical reference standard. Among eyes with an abnormal 10-2 VF, regression analyses were performed between the Amsler grid scotoma area and the 10-2 VF parameters (mean deviation [MD], scotoma extent [number of test points with P < 0.01 in total deviation map] and scotoma mean depth [mean sensitivity of test points with P < 0.01 in total deviation map]). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid scotoma area. A total of 106 eyes (53 patients) were included (mean ± standard deviation age, 24-2 MD and 10-2 MD = 66±12 years, -9.61±8.64 decibels [dB] and -9.75±9.00 dB, respectively). Sensitivity, specificity, and positive and negative predictive values of the Amsler grid test were 68%, 92%, 97%, and 46%, respectively. Sensitivity was 40% in eyes with 10-2 MD better than -6 dB, 58% in eyes with 10-2 MD between -12 and -6 dB, and 92% in eyes with 10-2 MD worse than -12 dB. The area under the receiver operating characteristic curve of the Amsler grid scotoma area was 0.810 (95% confidence interval, 0.723-0.880, P < 0.001). The Amsler grid scotoma area had the strongest relationship with 10-2 MD (quadratic R(2)=0.681), followed by 10-2 scotoma extent (quadratic R(2)=0.611) and 10-2 scotoma mean depth (quadratic R(2)=0.299) (all P < 0.001). The Amsler grid can be used to screen for moderate to severe central vision loss from glaucoma. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Framing the inborn aging process and longevity science.

    PubMed

    Farrelly, Colin

    2010-06-01

    The medical sciences are currently dominated by the "disease-model" approach to health extension, an approach that prioritizes the study of pathological mechanisms with the goal of discovering treatment modalities for specific diseases. This approach has marginalized research on the aging process itself, research that could lead to an intervention that retards aging, thus conferring health dividends that would far exceed what could be expected by eliminating any specific disease of aging. This paper offers a diagnosis of how this sub-optimal approach to health extension arose and some general prescriptions concerning how progress could be made in terms of adopting a more rational approach to health extension. Drawing on empirical findings from psychology and economics, "prospect theory" is applied to the challenges of "framing" the inborn aging process given the cognitive capacities of real (rather than rational) decision-makers under conditions of risk and uncertainty. Prospect theory reveals that preferences are in fact dependent on whether particular outcomes of a choice are regarded as "a loss" or "a gain", relative to a reference point (or "aspiration level for survival"). And this has significant consequences for the way biogerontologists ought to characterise the central aspirations of the field (i.e. to prevent disease versus extend lifespan). Furthermore, it reveals the importance of shifting the existing reference point of the medical sciences to one that is shaped by the findings of evolutionary biology and biodemography.

  9. Consideration of reference points for the management of renewable resources under an adaptive management paradigm

    USGS Publications Warehouse

    Irwin, Brian J.; Conroy, Michael J.

    2013-01-01

    The success of natural resource management depends on monitoring, assessment and enforcement. In support of these efforts, reference points (RPs) are often viewed as critical values of management-relevant indicators. This paper considers RPs from the standpoint of objective-driven decision making in dynamic resource systems, guided by principles of structured decision making (SDM) and adaptive resource management (AM). During the development of natural resource policy, RPs have been variously treated as either ‘targets’ or ‘triggers’. Under a SDM/AM paradigm, target RPs correspond approximately to value-based objectives, which may in turn be either of fundamental interest to stakeholders or intermediaries to other central objectives. By contrast, trigger RPs correspond to decision rules that are presumed to lead to desirable outcomes (such as the programme targets). Casting RPs as triggers or targets within a SDM framework is helpful towards clarifying why (or whether) a particular metric is appropriate. Further, the benefits of a SDM/AM process include elucidation of underlying untested assumptions that may reveal alternative metrics for use as RPs. Likewise, a structured decision-analytic framework may also reveal that failure to achieve management goals is not because the metrics are wrong, but because the decision-making process in which they are embedded is insufficiently robust to uncertainty, is not efficiently directed at producing a resource objective, or is incapable of adaptation to new knowledge.

  10. Gratkorn: A benchmark locality for the continental Sarmatian s.str. of the Central Paratethys

    NASA Astrophysics Data System (ADS)

    Gross, M.; Böhme, M.; Prieto, J.

    2011-11-01

    This paper presents one of the richest and most complete vertebrate faunas of the late Middle Miocene (~12 Ma) of Central Europe. Up to now, sixty-two vertebrate taxa, comprising all major groups (fishes, amphibians, reptiles, birds, mammals), have been recorded. Based on sedimentological and palaeobiological evidences, this Fossillagerstätte is assumed to originate from a floodplain paleosol formed on top of a braided river sequence. The fauna points to a highly structured, somewhat vegetated landscape with a wide array of habitats (e.g., fluvial channels, sporadically moist floodplains, short-lived ponds, savannah-like open areas and screes). It was preserved due to a rapid drowning and the switch to a freshwater lake environment. Palaeoclimatological data, derived from pedogenic features as well as from biota, indicate an overall semi-arid, subtropical climate with distinct seasonality (mean annual precipitation 486 ± 252 mm, mean annual temperature ~15°C). This underlines the late Middle/early Late Miocene dry-spell in Central Europe. From taphonomical point of view, the irregularly distributed but roughly associated larger vertebrate remains refer to an in situ accumulation of the bone bed. Splintered bones, gnawing marks as well as rhizoconcretions and root corrosion structures record some pre- and post-burial modification of the taphocoenose. However, the findings of pellet remains argue for a very fast burial and thus to a low degree of time-averaging. For this reason, the fossil fauna reflects the original vertebrate community rather well and is a cornerstone for the understanding of late Middle Miocene terrestrial ecosystems in this region. Certainly, Gratkorn will be one of the key faunas for a high-resolution continental biostratigraphy and the comprehension of Europe's faunal interchanges near the Middle/Late Miocene transition.

  11. Development of discrete choice model considering internal reference points and their effects in travel mode choice context

    NASA Astrophysics Data System (ADS)

    Sarif; Kurauchi, Shinya; Yoshii, Toshio

    2017-06-01

    In the conventional travel behavior models such as logit and probit, decision makers are assumed to conduct the absolute evaluations on the attributes of the choice alternatives. On the other hand, many researchers in cognitive psychology and marketing science have been suggesting that the perceptions of attributes are characterized by the benchmark called “reference points” and the relative evaluations based on them are often employed in various choice situations. Therefore, this study developed a travel behavior model based on the mental accounting theory in which the internal reference points are explicitly considered. A questionnaire survey about the shopping trip to the CBD in Matsuyama city was conducted, and then the roles of reference points in travel mode choice contexts were investigated. The result showed that the goodness-of-fit of the developed model was higher than that of the conventional model, indicating that the internal reference points might play the major roles in the choice of travel mode. Also shown was that the respondents seem to utilize various reference points: some tend to adopt the lowest fuel price they have experienced, others employ fare price they feel in perceptions of the travel cost.

  12. The Long-Wave Infrared Earth Image as a Pointing Reference for Deep-Space Optical Communications

    NASA Astrophysics Data System (ADS)

    Biswas, A.; Piazzolla, S.; Peterson, G.; Ortiz, G. G.; Hemmati, H.

    2006-11-01

    Optical communications from space require an absolute pointing reference. Whereas at near-Earth and even planetary distances out to Mars and Jupiter a laser beacon transmitted from Earth can serve as such a pointing reference, for farther distances extending to the outer reaches of the solar system, the means for meeting this requirement remains an open issue. We discuss in this article the prospects and consequences of utilizing the Earth image sensed in the long-wave infrared (LWIR) spectral band as a beacon to satisfy the absolute pointing requirements. We have used data from satellite-based thermal measurements of Earth to synthesize images at various ranges and have shown the centroiding accuracies that can be achieved with prospective LWIR image sensing arrays. The nonuniform emissivity of Earth causes a mispointing bias error term that exceeds a provisional pointing budget allocation when using simple centroiding algorithms. Other issues related to implementing thermal imaging of Earth from deep space for the purposes of providing a pointing reference are also reported.

  13. Solving multi-objective optimization problems in conservation with the reference point method

    PubMed Central

    Dujardin, Yann; Chadès, Iadine

    2018-01-01

    Managing the biodiversity extinction crisis requires wise decision-making processes able to account for the limited resources available. In most decision problems in conservation biology, several conflicting objectives have to be taken into account. Most methods used in conservation either provide suboptimal solutions or use strong assumptions about the decision-maker’s preferences. Our paper reviews some of the existing approaches to solve multi-objective decision problems and presents new multi-objective linear programming formulations of two multi-objective optimization problems in conservation, allowing the use of a reference point approach. Reference point approaches solve multi-objective optimization problems by interactively representing the preferences of the decision-maker with a point in the criteria (objectives) space, called the reference point. We modelled and solved the following two problems in conservation: a dynamic multi-species management problem under uncertainty and a spatial allocation resource management problem. Results show that the reference point method outperforms classic methods while illustrating the use of an interactive methodology for solving combinatorial problems with multiple objectives. The method is general and can be adapted to a wide range of ecological combinatorial problems. PMID:29293650

  14. Reference values of brachial-ankle pulse wave velocity according to age and blood pressure in a central Asia population.

    PubMed

    Yiming, Gulinuer; Zhou, Xianhui; Lv, Wenkui; Peng, Yi; Zhang, Wenhui; Cheng, Xinchun; Li, Yaodong; Xing, Qiang; Zhang, Jianghua; Zhou, Qina; Zhang, Ling; Lu, Yanmei; Wang, Hongli; Tang, Baopeng

    2017-01-01

    Brachial-ankle pulse wave velocity (baPWV), a direct measure of aortic stiffness, has increasingly become an important assessment for cardiovascular risk. The present study established the reference and normal values of baPWV in a Central Asia population in Xinjiang, China. We recruited participants from a central Asia population in Xinjiang, China. We performed multiple regression analysis to investigate the determinants of baPWV. The median and 10th-90th percentiles were calculated to establish the reference and normal values based on these categories. In total, 5,757 Han participants aged 15-88 years were included in the present study. Spearman correlation analysis showed that age (r = 0.587, p < 0.001) and mean blood pressure (MBP, r = 0.599, p <0.001) were the major factors influencing the values of baPWV in the reference population. Furthermore, in the multiple linear regression analysis, the standardized regression coefficients of age (0.445) and MBP (0.460) were much higher than those of body mass index, triglyceride, and glycemia (-0.054, 0.035, and 0.033, respectively). In the covariance analysis, after adjustment for age and MBP, only diabetes was the significant independent determinant of baPWV (p = 0.009). Thus, participants with diabetes were excluded from the reference value population. The reference values ranged from 14.3 to 25.2 m/s, and the normal values ranged from 13.9 to 21.2 m/s. This is the first study that has established the reference and normal values for baPWV according to age and blood pressure in a Central Asia population.

  15. Prospective, observational study comparing automated and visual point-of-care urinalysis in general practice

    PubMed Central

    van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier

    2016-01-01

    Objective Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. Setting The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Primary and secondary outcome measures Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Results Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Conclusions Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. PMID:27503860

  16. Prospective, observational study comparing automated and visual point-of-care urinalysis in general practice.

    PubMed

    van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier

    2016-08-08

    Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Synthetic Minor NSR Permit: Red Cedar Gathering Company - South Ignacio Central Delivery Point

    EPA Pesticide Factsheets

    This page contains the final synthetic minor NSR permit for the Red Cedar Gathering Company, South Ignacio Central Delivery Point, located on the Southern Ute Indian Reservation in La Plata County, CO.

  18. Standardized Fault-Tolerant Sensing Nodes for an Intelligent Turbine Engine Control System (Preprint)

    DTIC Science & Technology

    2013-05-01

    representation of a centralized control system on a turbine engine. All actuators and sensors are point-to-point cabled to the controller ( FADEC ) which...electronics themselves. Figure 1: Centralized Control System Each function resides within the FADEC and uses Unique Point-to-Point Analog...distributed control system on the same turbine engine. The actuators and sensors interface to Smart Nodes which, in turn communicate to the FADEC via

  19. Patron Preference in Reference Service Points.

    ERIC Educational Resources Information Center

    Morgan, Linda

    1980-01-01

    Behavior of patrons choosing between a person sitting at a counter and one sitting at a desk at each of two reference points was observed at the reference department during remodeling at the M. D. Anderson Library of the University of Houston. Results showed a statistically relevant preference for the counter. (Author/JD)

  20. Pointing As a Socio-Pragmatic Cue to Particular vs.Generic Reference

    ERIC Educational Resources Information Center

    Meyer, Meredith; Baldwin, Dare A.

    2013-01-01

    Generic noun phrases, or generics, refer to abstract kind categories ("Dogs" bark) rather than particular individuals ("Those dogs" bark). How do children distinguish these distinct kinds of reference? We examined the role of one socio-pragmatic cue, namely pointing, in producing and comprehending generic versus particular…

  1. Null test fourier domain alignment technique for phase-shifting point diffraction interferometer

    DOEpatents

    Naulleau, Patrick; Goldberg, Kenneth Alan

    2000-01-01

    Alignment technique for calibrating a phase-shifting point diffraction interferometer involves three independent steps where the first two steps independently align the image points and pinholes in rotation and separation to a fixed reference coordinate system, e.g, CCD. Once the two sub-elements have been properly aligned to the reference in two parameters (separation and orientation), the third step is to align the two sub-element coordinate systems to each other in the two remaining parameters (x,y) using standard methods of locating the pinholes relative to some easy to find reference point.

  2. In your face: transcendence in embodied interaction

    PubMed Central

    Gallagher, Shaun

    2014-01-01

    In cognitive psychology, studies concerning the face tend to focus on questions about face recognition, theory of mind (ToM) and empathy. Questions about the face, however, also fit into a very different set of issues that are central to ethics. Based especially on the work of Levinas, philosophers have come to see that reference to the face of another person can anchor conceptions of moral responsibility and ethical demand. Levinas points to a certain irreducibility and transcendence implicit in the face of the other. In this paper I argue that the notion of transcendence involved in this kind of analysis can be given a naturalistic interpretation by drawing on recent interactive approaches to social cognition found in developmental psychology, phenomenology, and the study of autism. PMID:25071523

  3. Central Alaska Network vital signs monitoring plan

    USGS Publications Warehouse

    MacCluskie, Margaret C.; Oakley, Karen L.; McDonald, Trent; Wilder, Doug

    2005-01-01

    Denali National Park and Preserve, Wrangell-St. Elias National Park and Preserve, and Yukon-Charley Rivers National Preserve have been organized into the Central Alaska Network (CAKN) for the purposes of carrying out ecological monitoring activities under the National Park Services’ Vital Signs Monitoring program. The Phase III Report is the initial draft of the Vital Signs Monitoring Plan for the Central Alaska Network. It includes updated material from the Phase I and II documents. This report, and draft protocols for 11 of the network’s Vital Signs, were peer reviewed early in 2005. Review comments were incorporated into the document bringing the network to the final stage of having a Vital Signs Monitoring Plan. Implementation of the program will formally begin in FY 2006. The broad goals of the CAKN monitoring program are to: (1) better understand the dynamic nature and condition of park ecosystems; and (2) provide reference points for comparisons with other, altered environments. The focus of the CAKN program will be to monitor ecosystems in order to detect change in ecological components and in the relationships among the components. Water quality monitoring is fully integrated within the CAKN monitoring program. A monitoring program for lentic (non-moving water) has been determined, and the program for lotic systems (moving water) is under development.

  4. Synthetic Minor NSR Permit: BP America Production Company - Salvador I/II Central Delivery Point

    EPA Pesticide Factsheets

    This page contains the final synthetic minor NSR permit for the BP America Production Company, Salvador I/II Central Delivery Point, located on the Southern Ute Indian Reservation in La Plata County, CO.

  5. Diabetes insipidus - central

    MedlinePlus

    ... Alternative Names Central diabetes insipidus; Neurogenic diabetes insipidus Images Endocrine glands References Brimioulle S. Diabetes insipidus. In: Vincent J-L, Abraham E, Moore FA, Kochanek PM, Fink ...

  6. 40 CFR 63.652 - Emissions averaging provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... emissions average. This must include any Group 1 emission points to which the reference control technology... controls for a Group 1 emission point, the pollution prevention measure alone does not have to reduce... in control after November 15, 1990; (2) Group 1 emission points that are controlled by a reference...

  7. 40 CFR 63.652 - Emissions averaging provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... emissions average. This must include any Group 1 emission points to which the reference control technology... controls for a Group 1 emission point, the pollution prevention measure alone does not have to reduce... in control after November 15, 1990; (2) Group 1 emission points that are controlled by a reference...

  8. Contour changes in human alveolar bone following tooth extraction of the maxillary central incisor.

    PubMed

    Li, Bei; Wang, Yao

    2014-12-01

    The purpose of this study was to apply cone-beam computed tomography (CBCT) to observe contour changes in human alveolar bone after tooth extraction of the maxillary central incisor and to provide original morphological evidence for aesthetic implant treatment in the maxillary anterior area. Forty patients were recruited into the study. Each patient had two CBCT scans (CBCT I and CBCT II), one taken before and one taken three months after tooth extraction of maxillary central incisor (test tooth T). A fixed anatomic reference point was used to orient the starting axial slice of the two scans. On three CBCT I axial slices, which represented the deep, middle, and shallow layers of the socket, labial and palatal alveolar bone widths of T were measured. The number of sagittal slices from the start point to the pulp centre of T was recorded. On three CBCT II axial slices, the pulp centres of extracted T were oriented according to the number of moved sagittal slices recorded in CBCT I. Labial and palatal alveolar bone widths at the oriented sites were measured. On the CBCT I axial slice which represented the middle layer of the socket, sagittal slices were reconstructed. Relevant distances of T on the sagittal slice were measured, as were the alveolar bone width and tooth length of the opposite central incisor. On the CBCT II axial slice, which represented the middle layer of the socket, relevant distances recorded in CBCT I were transferred on the sagittal slice. The height reduction of alveolar bone on labial and palatal sides was measured, as were the alveolar bone width and tooth length of the opposite central incisor at the oriented site. Intraobserver reliability assessed by intraclass correlation coefficients (ICCs) was high. Paired sample t-tests were performed. The alveolar bone width and tooth length of the opposite central incisor showed no statistical differences (P<0.05). The labial alveolar bone widths of T at the deep, middle, and shallow layers all showed statistical differences. However, no palatal alveolar bone widths showed any statistical differences. The width reduction of alveolar bone was 1.2, 1.6, and 2.7 mm at the deep, middle, and shallow layers, respectively. The height reduction of alveolar bone on labial and palatal sides of T both showed statistical differences, which was 1.9 and 1.1 mm, respectively.

  9. The Neurobiology of Reference-Dependent Value Computation

    PubMed Central

    De Martino, Benedetto; Kumaran, Dharshan; Holt, Beatrice; Dolan, Raymond J.

    2009-01-01

    A key focus of current research in neuroeconomics concerns how the human brain computes value. Although, value has generally been viewed as an absolute measure (e.g., expected value, reward magnitude), much evidence suggests that value is more often computed with respect to a changing reference point, rather than in isolation. Here, we present the results of a study aimed to dissociate brain regions involved in reference-independent (i.e., “absolute”) value computations, from those involved in value computations relative to a reference point. During functional magnetic resonance imaging, subjects acted as buyers and sellers during a market exchange of lottery tickets. At a behavioral level, we demonstrate that subjects systematically accorded a higher value to objects they owned relative to those they did not, an effect that results from a shift in reference point (i.e., status quo bias or endowment effect). Our results show that activity in orbitofrontal cortex and dorsal striatum track parameters such as the expected value of lottery tickets indicating the computation of reference-independent value. In contrast, activity in ventral striatum indexed the degree to which stated prices, at a within-subjects and between-subjects level, were distorted with respect to a reference point. The findings speak to the neurobiological underpinnings of reference dependency during real market value computations. PMID:19321780

  10. Managing Inadvertent Arterial Catheterization During Central Venous Access Procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nicholson, Tony, E-mail: Tony.Nicholson@leedsth.nhs.uk; Ettles, Duncan; Robinson, Graham

    2004-01-15

    Purpose: Approximately 200,000 central venous catheterizations are carried out annually in the National Health Service in the United Kingdom. Inadvertent arterial puncture occurs in up to 3.7%. Significant morbidity and death has been reported. We report on our experience in the endovascular treatment of this iatrogenic complication. Methods: Retrospective analysis was carried out of 9 cases referred for endovascular treatment of inadvertent arterial puncture during central venous catheterization over a 5 year period. Results: It was not possible to obtain accurate figures on the numbers of central venous catheterizations carried out during the time period. Five patients were referred withmore » carotid or subclavian pseudoaneurysms and hemothorax following inadvertent arterial catheter insertion and subsequent removal. These patients all underwent percutaneous balloon tamponade and/or stent-graft insertion. More recently 4 patients were referred with the catheter still in situ and were successfully treated with a percutaneous closure device. Conclusion: If inadvertent arterial catheterization during central venous access procedures is recognized and catheters removed, sequelae can be treated percutaneously. However, once the complication is recognized it is better to leave the catheter in situ and seal the artery percutaneously with a closure device.« less

  11. 78 FR 77019 - Energy Conservation Program: Energy Conservation Standards for Certain Consumer Products

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... Regulations the definitions for ``through-the-wall central air conditioner'' and ``through-the-wall central... superseded effective in 2006, and the now defunct references to the ``through-the-wall air conditioner and... definitions for ``through-the-wall central air conditioner'' and ``through-the-wall central air conditioning...

  12. Neuroimaging in attention-deficit hyperactivity disorder: beyond the frontostriatal circuitry.

    PubMed

    Cherkasova, Mariya V; Hechtman, Lily

    2009-10-01

    To review the findings of structural and functional neuroimaging studies in attention-deficit hyperactivity disorder (ADHD), with a focus on abnormalities reported in brain regions that lie outside the frontostriatal circuitry, which is currently believed to play a central role in the pathophysiology of ADHD. Relevant publications were found primarily by searching the MEDLINE and PubMed databases using the keywords ADHD and the abbreviations of magnetic resonance imaging (MRI), functional MRI, positron emission tomography, and single photon emission computed tomography. The reference lists of the articles found through the databases were then reviewed for the purpose of finding additional articles. There is now substantial evidence of structural and functional alterations in regions outside the frontostriatal circuitry in ADHD, most notably in the cerebellum and the parietal lobes. Although there is compelling evidence suggesting that frontostriatal dysfunction may be central to the pathophysiology of ADHD, the neuroimaging findings point to distributed neural substrates rather than a single one. More research is needed to elucidate the nature of contributions of nonfrontostriatal regions to the pathophysiology of ADHD.

  13. A pilot study using an infrared imaging system in prevention of post-endoscopic submucosal dissection ulcer bleeding.

    PubMed

    Yoshida, Yukinaga; Matsuda, Koji; Tamai, Naoto; Yoshizawa, Kai; Nikami, Toshiki; Ishiguro, Haruya; Tajiri, Hisao

    2014-01-01

    Endoscopic submucosal dissection (ESD) for superficial gastric neoplasm is a curative method. The aim of this study was to detect potential nonbleeding visible vessels (NBVVs) by using an infrared imaging (IRI) system. A total of 24 patients (25 lesions) were consecutively enrolled between March 2010 and December 2010. The day after ESD, endoscopist A (K.M.), who was blinded to the actual procedure of ESD, performed esophagogastroduodenoscopy (EGD) of the post-ESD ulcer base using the IRI system. Endoscopist A marked gray/blue points in the hard-copy images with the IRI system. After the first procedure, endoscopist B (Y.Y.), who was blinded to the results recorded by endoscopist A, performed a second EGD with white light endoscopy and administered water-jet pressure with the maximum level of an Olympus flushing pump onto the post-ESD ulcer base. This test can cause iatrogenic bleeding via application of pressure to NBVV in the post-ESD ulcer. The IRI system detected 58 gray points and 71 blue points. The post-ESD ulcer was divided into the central area and the peripheral area. There were 14 gray points (24 %) in the central area and 44 gray points (76 %) in the peripheral area. There were 19 blue points (27 %) in the central area and 52 blue points (73 %) in the peripheral area. There was no significant difference when comparing the distribution of gray points and blue points. Bleeding occurred with a water-jet pressure in 11 of 58 gray points and in none of the blue points (P = 0.000478). Among the gray points, bleeding in response to a water-jet pressure occurred in 2 points in the central area and in 9 points in the peripheral area. The IRI system detects visible vessels (VVs) that are in no need of coagulation as blue points, and VVs have a potential risk of bleeding as gray points.

  14. Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.

    PubMed

    Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K

    2013-11-01

    To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (p<0.05). The largest contact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (P<0.05). the apicogingival dimension of the contact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.

  15. Reference in Action: Links between Pointing and Language

    ERIC Educational Resources Information Center

    Cooperrider, Kensy Andrew

    2011-01-01

    When referring to things in the world, speakers produce utterances that are composites of speech and action. Pointing gestures are a pervasive part of such composite utterances, but many questions remain about exactly how pointing is integrated with speech. In this dissertation I present three strands of research that investigate relations of…

  16. Evidence-Based Practice Point-of-Care Resources: A Quantitative Evaluation of Quality, Rigor, and Content.

    PubMed

    Campbell, Jared M; Umapathysivam, Kandiah; Xue, Yifan; Lockwood, Craig

    2015-12-01

    Clinicians and other healthcare professionals need access to summaries of evidence-based information in order to provide effective care to their patients at the point-of-care. Evidence-based practice (EBP) point-of-care resources have been developed and are available online to meet this need. This study aimed to develop a comprehensive list of available EBP point-of-care resources and evaluate their processes and policies for the development of content, in order to provide a critical analysis based upon rigor, transparency and measures of editorial quality to inform healthcare providers and promote quality improvement amongst publishers of EBP resources. A comprehensive and systematic search (Pubmed, CINAHL, and Cochrane Central) was undertaken to identify available EBP point-of-care resources, defined as "web-based medical compendia specifically designed to deliver predigested, rapidly accessible, comprehensive, periodically updated, and evidence-based information (and possibly also guidance) to clinicians." A pair of investigators independently extracted information on general characteristics, content presentation, editorial quality, evidence-based methodology, and breadth and volume. Twenty-seven summary resources were identified, of which 22 met the predefined inclusion criteria for EBP point-of-care resources, and 20 could be accessed for description and assessment. Overall, the upper quartile of EBP point-of-care providers was assessed to be UpToDate, Nursing Reference Centre, Mosby's Nursing Consult, BMJ Best Practice, and JBI COnNECT+. The choice of which EBP point-of-care resources are suitable for an organization is a decision that depends heavily on the unique requirements of that organization and the resources it has available. However, the results presented in this study should enable healthcare providers to make that assessment in a clear, evidence-based manner, and provide a comprehensive list of the available options. © 2015 Sigma Theta Tau International.

  17. Ecosystem approach to fisheries: Exploring environmental and trophic effects on Maximum Sustainable Yield (MSY) reference point estimates

    PubMed Central

    Kumar, Rajeev; Pitcher, Tony J.; Varkey, Divya A.

    2017-01-01

    We present a comprehensive analysis of estimation of fisheries Maximum Sustainable Yield (MSY) reference points using an ecosystem model built for Mille Lacs Lake, the second largest lake within Minnesota, USA. Data from single-species modelling output, extensive annual sampling for species abundances, annual catch-survey, stomach-content analysis for predatory-prey interactions, and expert opinions were brought together within the framework of an Ecopath with Ecosim (EwE) ecosystem model. An increase in the lake water temperature was observed in the last few decades; therefore, we also incorporated a temperature forcing function in the EwE model to capture the influences of changing temperature on the species composition and food web. The EwE model was fitted to abundance and catch time-series for the period 1985 to 2006. Using the ecosystem model, we estimated reference points for most of the fished species in the lake at single-species as well as ecosystem levels with and without considering the influence of temperature change; therefore, our analysis investigated the trophic and temperature effects on the reference points. The paper concludes that reference points such as MSY are not stationary, but change when (1) environmental conditions alter species productivity and (2) fishing on predators alters the compensatory response of their prey. Thus, it is necessary for the management to re-estimate or re-evaluate the reference points when changes in environmental conditions and/or major shifts in species abundance or community structure are observed. PMID:28957387

  18. Instrument Pointing Capabilities: Past, Present, and Future

    NASA Technical Reports Server (NTRS)

    Blackmore, Lars; Murray, Emmanuell; Scharf, Daniel P.; Aung, Mimi; Bayard, David; Brugarolas, Paul; Hadaegh, Fred; Lee, Allan; Milman, Mark; Sirlin, Sam; hide

    2011-01-01

    This paper surveys the instrument pointing capabilities of past, present and future space telescopes and interferometers. As an important aspect of this survey, we present a taxonomy for "apples-to-apples" comparisons of pointing performances. First, pointing errors are defined relative to either an inertial frame or a celestial target. Pointing error can then be further sub-divided into DC, that is, steady state, and AC components. We refer to the magnitude of the DC error relative to the inertial frame as absolute pointing accuracy, and we refer to the magnitude of the DC error relative to a celestial target as relative pointing accuracy. The magnitude of the AC error is referred to as pointing stability. While an AC/DC partition is not new, we leverage previous work by some of the authors to quantitatively clarify and compare varying definitions of jitter and time window averages. With this taxonomy and for sixteen past, present, and future missions, pointing accuracies and stabilities, both required and achieved, are presented. In addition, we describe the attitude control technologies used to and, for future missions, planned to achieve these pointing performances.

  19. Point cloud registration from local feature correspondences-Evaluation on challenging datasets.

    PubMed

    Petricek, Tomas; Svoboda, Tomas

    2017-01-01

    Registration of laser scans, or point clouds in general, is a crucial step of localization and mapping with mobile robots or in object modeling pipelines. A coarse alignment of the point clouds is generally needed before applying local methods such as the Iterative Closest Point (ICP) algorithm. We propose a feature-based approach to point cloud registration and evaluate the proposed method and its individual components on challenging real-world datasets. For a moderate overlap between the laser scans, the method provides a superior registration accuracy compared to state-of-the-art methods including Generalized ICP, 3D Normal-Distribution Transform, Fast Point-Feature Histograms, and 4-Points Congruent Sets. Compared to the surface normals, the points as the underlying features yield higher performance in both keypoint detection and establishing local reference frames. Moreover, sign disambiguation of the basis vectors proves to be an important aspect in creating repeatable local reference frames. A novel method for sign disambiguation is proposed which yields highly repeatable reference frames.

  20. Medical ethics in times of war and insurrection: rights and duties.

    PubMed

    Benatar, S R

    1993-01-01

    In this paper I shall take the Geneva Conventions and Additional Protocols as my point of departure and link these with the International Declaration of Human Rights as a statement of faith and of aspirations.... The second part of my paper will focus on medical morality with brief reference to various languages of moral discourse and to differences in conceptual logic which underpin debates on duties and rights with particular reference to the circumstances of conflict. While acknowledging the value of talking of rights as primary I shall also suggest that the shift away from discourse on duties and obligations as primary undermines the likelihood of super-erogatory moral action. I shall conclude by emphasizing the centrality of acceptance by the State and the military of their duty to the injured and to medical personnel caring for them, if man's inhumanity to man, particularly evident during times of war, is to be kept out of our concern for each other as human beings even when nations are pitted against each other in the ongoing, but hopefully not eternal, struggle for material and ideological power.

  1. Circulating intact and cleaved forms of the urokinase-type plasminogen activator receptor: biological variation, reference intervals and clinical useful cut-points.

    PubMed

    Thurison, Tine; Christensen, Ib J; Lund, Ida K; Nielsen, Hans J; Høyer-Hansen, Gunilla

    2015-01-15

    High levels of circulating forms of the urokinase-type plasminogen activator receptor (uPAR) are significantly associated to poor prognosis in cancer patients. Our aim was to determine biological variations and reference intervals of the uPAR forms in blood, and in addition, to test the clinical relevance of using these as cut-points in colorectal cancer (CRC) prognosis. uPAR forms were measured in citrated and EDTA plasma samples using time-resolved fluorescence immunoassays. Diurnal, intra- and inter-individual variations were assessed in plasma samples from cohorts of healthy individuals. Reference intervals were determined in plasma from healthy individuals randomly selected from a Danish multi-center cross-sectional study. A cohort of CRC patients was selected from the same cross-sectional study. The reference intervals showed a slight increase with age and women had ~20% higher levels. The intra- and inter-individual variations were ~10% and ~20-30%, respectively and the measured levels of the uPAR forms were within the determined 95% reference intervals. No diurnal variation was found. Applying the normal upper limit of the reference intervals as cut-point for dichotomizing CRC patients revealed significantly decreased overall survival of patients with levels above this cut-point of any uPAR form. The reference intervals for the different uPAR forms are valid and the upper normal limits are clinically relevant cut-points for CRC prognosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Automated and continual determination of radio telescope reference points with sub-mm accuracy: results from a campaign at the Onsala Space Observatory

    NASA Astrophysics Data System (ADS)

    Lösler, Michael; Haas, Rüdiger; Eschelbach, Cornelia

    2013-08-01

    The Global Geodetic Observing System (GGOS) requires sub-mm accuracy, automated and continual determinations of the so-called local tie vectors at co-location stations. Co-location stations host instrumentation for several space geodetic techniques and the local tie surveys involve the relative geometry of the reference points of these instruments. Thus, these reference points need to be determined in a common coordinate system, which is a particular challenge for rotating equipment like radio telescopes for geodetic Very Long Baseline Interferometry. In this work we describe a concept to achieve automated and continual determinations of radio telescope reference points with sub-mm accuracy. We developed a monitoring system, including Java-based sensor communication for automated surveys, network adjustment and further data analysis. This monitoring system was tested during a monitoring campaign performed at the Onsala Space Observatory in the summer of 2012. The results obtained in this campaign show that it is possible to perform automated determination of a radio telescope reference point during normal operations of the telescope. Accuracies on the sub-mm level can be achieved, and continual determinations can be realized by repeated determinations and recursive estimation methods.

  3. Synthetic Minor NSR Permit: BP America Production Company - Treating Site #8 Central Delivery Point

    EPA Pesticide Factsheets

    This page contains the response to public comments and the final synthetic minor NSR permit for the BP America Production Company, Treating Site #8 Central Delivery Point, located on the Southern Ute Indian Reservation in La Plata County, CO.

  4. [National epidemiological survey on childhood obesity, 2006].

    PubMed

    Ding, Zong-yi

    2008-03-01

    The purpose of the 3rd national survey on childhood obesity was conducted not only to understand the present status and trends of childhood obesity in China since the last survey conducted 10 years ago, but also to reveal the health status of preschool children at nutrition transit period and to evaluate the efficacy and sensitivity of cited reference population, criteria and cut-off point of body mass index (BMI), adiposity rebound age, waist/hip ratio and other parameters relevant to the diagnosis of obesity made by the national task force on childhood obesity of China (NTFCOC). A total of 84,766 children aged 0 - 7 years were recruited in the survey by the random cluster sampling which represented a 1, 414, 220 children's population from 11 cities covered north, central, south and west regions of China. The criteria of screening overweight/obesity was more than 1 Z-score/2 Z-score of the medium of reference value of weight for height made by WHO. Length-height/weight for all subjects and waist/hip/thigh circumference and blood pressure data for children 3 - 6 years of age were measured. The prevalence of overweight and obesity, overweight-obesity ratio, adiposity rebound age and BMI were calculated. The enumeration and measurement data were statistically managed by chi-square test and T-test, respectively using SPSS version 12.0 and the significance level was 0.05. (1) The prevalence of obesity and overweight was 7.2% and 19.8% for all; 8.9% and 22.2% for boys, and 5.3% and 17.0% for girls, respectively, which is 3.6/4.7 times higher than that of 1996 respectively, the annual increase rate of obesity and overweight was in average 156% and 52%, respectively. The distribution pattern of prevalence of overweight and obesity in geographic areas and gender was that the northern regions had higher prevalence than the west and the central regions and the prevalence in boys was higher than in girls. The obesity/overweight ratio (OOR) was still at a high risk level. (2) BMI at 1 month after birth was higher than 16.5, then increased to the top of 17.8 at 1 year of age and decreased to the bottom of 15.7 at 5.5 years of age and increased a little since then. It was never higher than 18 of diagnosis point of obesity during the preschool age period. (3) The adiposity rebound age was 5.5 years of age in this study and delayed half a year as compared with that seen in 1999. The adiposity rebound ratio at first half year after birth (ARR1) was 0.56 and 0.97 at second half year after birth (ARR2) which is an acceptable level according to the cut-off point made by NTFCOC and lower than the level obtained 10 years ago. (4) The pseudo-overweight phenomenon can be seen in the western regions which was derived from linear growth retardation and showed that both the malnutrition and obesity are a health problem in the poverty and maintain area of the western regions.(5) The 12.9% of obese children who's blood pressure was higher than 95th percentile of reference value and 17.2% of them had a waist/hip ratio higher than 1.0 which is a warning point for the risk factor of CHD made by the NTFCOC. (6) The data showed that all the reference population and it's cut-off point for BMI, adiposity rebound age/ratio, waist/hip ratio etc. made by NTFCOC is valuable, reliable and practicable. The prevalence of childhood obesity and high blood pressure in obese children has been increased sharply during the recent 10 years, which is a out of control and a severe hazard to obese children. The early prevention and management of childhood obesity is urgently needed.

  5. Real-time and accurate rail wear measurement method and experimental analysis.

    PubMed

    Liu, Zhen; Li, Fengjiao; Huang, Bangkui; Zhang, Guangjun

    2014-08-01

    When a train is running on uneven or curved rails, it generates violent vibrations on the rails. As a result, the light plane of the single-line structured light vision sensor is not vertical, causing errors in rail wear measurements (referred to as vibration errors in this paper). To avoid vibration errors, a novel rail wear measurement method is introduced in this paper, which involves three main steps. First, a multi-line structured light vision sensor (which has at least two linear laser projectors) projects a stripe-shaped light onto the inside of the rail. Second, the central points of the light stripes in the image are extracted quickly, and the three-dimensional profile of the rail is obtained based on the mathematical model of the structured light vision sensor. Then, the obtained rail profile is transformed from the measurement coordinate frame (MCF) to the standard rail coordinate frame (RCF) by taking the three-dimensional profile of the measured rail waist as the datum. Finally, rail wear constraint points are adopted to simplify the location of the rail wear points, and the profile composed of the rail wear points are compared with the standard rail profile in RCF to determine the rail wear. Both real data experiments and simulation experiments show that the vibration errors can be eliminated when the proposed method is used.

  6. Pointing and Reference in Sign Language and Spoken Language: Anchoring vs. Identifying

    ERIC Educational Resources Information Center

    Barberà, Gemma; Zwets, Martine

    2013-01-01

    In both signed and spoken languages, pointing serves to direct an addressee's attention to a particular entity. This entity may be either present or absent in the physical context of the conversation. In this article we focus on pointing directed to nonspeaker/nonaddressee referents in Sign Language of the Netherlands (Nederlandse Gebarentaal,…

  7. Comparison of results of fluconazole disk diffusion testing for Candida species with results from a central reference laboratory in the ARTEMIS global antifungal surveillance program.

    PubMed

    Pfaller, M A; Hazen, K C; Messer, S A; Boyken, L; Tendolkar, S; Hollis, R J; Diekema, D J

    2004-08-01

    The accuracy of antifungal susceptibility tests is important for accurate resistance surveillance and for the clinical management of patients with serious infections. Our main objective was to compare the results of fluconazole disk diffusion testing of Candida spp. performed by ARTEMIS participating centers with disk diffusion and MIC results obtained by the central reference laboratory. A total of 2,949 isolates of Candida spp. were tested by NCCLS disk diffusion and reference broth microdilution methods in the central reference laboratory. These results were compared to the results of disk diffusion testing performed in the 54 participating centers. All tests were performed and interpreted following NCCLS recommendations. Overall categorical agreement between participant disk diffusion test results and reference laboratory MIC results was 87.4%, with 0.2% very major errors (VME) and 3.3% major errors (ME). The categorical agreement between the disk diffusion test results obtained in the reference laboratory with the MIC test results was similar: 92.8%. Likewise, good agreement was observed between participant disk diffusion test results and reference laboratory disk diffusion test results: 90.4%, 0.4% VME, and 3.4% ME. The disk diffusion test was especially reliable in detecting those isolates of Candida spp. that were characterized as resistant by reference MIC testing. External quality assurance data obtained by surveillance programs such as the ARTEMIS Global Antifungal Surveillance Program ensure the generation of useful surveillance data and result in the continued improvement of antifungal susceptibility testing practices.

  8. Metonymy and reference-point errors in novice programming

    NASA Astrophysics Data System (ADS)

    Miller, Craig S.

    2014-07-01

    When learning to program, students often mistakenly refer to an element that is structurally related to the element that they intend to reference. For example, they may indicate the attribute of an object when their intention is to reference the whole object. This paper examines these reference-point errors through the context of metonymy. Metonymy is a rhetorical device where the speaker states a referent that is structurally related to the intended referent. For example, the following sentence states an office bureau but actually refers to a person working at the bureau: The tourist asked the travel bureau for directions to the museum. Drawing upon previous studies, I discuss how student reference errors may be consistent with the use of metonymy. In particular, I hypothesize that students are more likely to reference an identifying element even when a structurally related element is intended. I then present two experiments, which produce results consistent with this analysis. In both experiments, students are more likely to produce reference-point errors that involve identifying attributes than descriptive attributes. Given these results, I explore the possibility that students are relying on habits of communication rather than the mechanistic principles needed for successful programming. Finally I discuss teaching interventions using live examples and how metonymy may be presented to non-computing students as pedagogy for computational thinking.

  9. Are tender point injections beneficial: the role of tonic nociception in fibromyalgia.

    PubMed

    Staud, Roland

    2006-01-01

    Characteristic symptoms of fibromyalgia syndrome (FM) include widespread pain, fatigue, sleep abnormalities, and distress. FM patients show psychophysical evidence for mechanical, thermal, and electrical hyperalgesia. To fulfill FM criteria, the mechanical hyperalgesia needs to be widespread and present in at least 11 out of 18 well-defined body areas (tender points). Peripheral and central abnormalities of nociception have been described in FM and these changes may be relevant for the increased pain experienced by these patients. Important nociceptor systems in the skin and muscle seem to undergo profound changes in FM patients by yet unknown mechanisms. These changes may result from the release of algesic substances after muscle or other soft tissue injury. These pain mediators can sensitize important nociceptor systems, including the transient receptor potential channel, vanilloid subfamily member 1 (TRPV1), acid sensing ion channel (ASIC) receptors, and purino-receptors (P2X3). Subsequently, tissue mediators of inflammation and nerve growth factors can excite these receptors and cause substantial changes in pain sensitivity. FM pain is widespread and does not seem to be restricted to tender points (TP). It frequently comprises multiple areas of deep tissue pain (trigger points) with adjacent much larger areas of referred pain. Analgesia of areas of extensive nociceptive input has been found to provide often long lasting local as well as general pain relief. Thus interventions aimed at reducing local FM pain seem to be effective but need to focus less on tender points but more on trigger points (TrP) and other body areas of heightened pain and inflammation.

  10. [Study on the experimental application of floating-reference method to noninvasive blood glucose sensing].

    PubMed

    Yu, Hui; Qi, Dan; Li, Heng-da; Xu, Ke-xin; Yuan, Wei-jie

    2012-03-01

    Weak signal, low instrument signal-to-noise ratio, continuous variation of human physiological environment and the interferences from other components in blood make it difficult to extract the blood glucose information from near infrared spectrum in noninvasive blood glucose measurement. The floating-reference method, which analyses the effect of glucose concentration variation on absorption coefficient and scattering coefficient, gets spectrum at the reference point and the measurement point where the light intensity variations from absorption and scattering are counteractive and biggest respectively. By using the spectrum from reference point as reference, floating-reference method can reduce the interferences from variation of physiological environment and experiment circumstance. In the present paper, the effectiveness of floating-reference method working on improving prediction precision and stability was assessed through application experiments. The comparison was made between models whose data were processed with and without floating-reference method. The results showed that the root mean square error of prediction (RMSEP) decreased by 34.7% maximally. The floating-reference method could reduce the influences of changes of samples' state, instrument noises and drift, and improve the models' prediction precision and stability effectively.

  11. Bibliographic Control in South Africa

    ERIC Educational Resources Information Center

    Musiker, Reuben

    1972-01-01

    The author sets as his task the consideration of the present state of bibliographical control of South Africa's bookstock with special reference to centralization and decentralization. (20 references) (Author/SJ)

  12. Effect of Receiver Choosing on Point Positions Determination in Network RTK

    NASA Astrophysics Data System (ADS)

    Bulbul, Sercan; Inal, Cevat

    2016-04-01

    Nowadays, the developments in GNSS technique allow to determinate point positioning in real time. Initially, point positioning was determined by RTK (Real Time Kinematic) based on a reference station. But, to avoid systematic errors in this method, distance between the reference points and rover receiver must be shorter than10 km. To overcome this restriction in RTK method, the idea of setting more than one reference point had been suggested and, CORS (Continuously Operations Reference Systems) was put into practice. Today, countries like ABD, Germany, Japan etc. have set CORS network. CORS-TR network which has 146 reference points has also been established in 2009 in Turkey. In CORS-TR network, active CORS approach was adopted. In Turkey, CORS-TR reference stations covering whole country are interconnected and, the positions of these stations and atmospheric corrections are continuously calculated. In this study, in a selected point, RTK measurements based on CORS-TR, were made with different receivers (JAVAD TRIUMPH-1, TOPCON Hiper V, MAGELLAN PRoMark 500, PENTAX SMT888-3G, SATLAB SL-600) and with different correction techniques (VRS, FKP, MAC). In the measurements, epoch interval was taken as 5 seconds and measurement time as 1 hour. According to each receiver and each correction technique, means and differences between maximum and minimum values of measured coordinates, root mean squares in the directions of coordinate axis and 2D and 3D positioning precisions were calculated, the results were evaluated by statistical methods and the obtained graphics were interpreted. After evaluation of the measurements and calculations, for each receiver and each correction technique; the coordinate differences between maximum and minimum values were measured to be less than 8 cm, root mean squares in coordinate axis directions less than ±1.5 cm, 2D point positioning precisions less than ±1.5 cm and 3D point positioning precisions less than ±1.5 cm. In the measurement point, it has been concluded that VRS correction technique is generally better than other corrections techniques.

  13. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Time Series of Greenland Ice-Sheet Elevations and Mass Changes from ICESat 2003-2009

    NASA Astrophysics Data System (ADS)

    Zwally, H. J.; Li, J.; Medley, B.; Robbins, J. W.; Yi, D.

    2015-12-01

    We follow the repeat-track analysis (RTA) of ICESat surface-elevation data by a second stage that adjusts the measured elevations on repeat passes to the reference track taking into account the cross-track slope (αc), in order to construct elevation time series. αc are obtained from RTA simultaneous solutions for αc, dh/dt, and h0. The height measurements on repeat tracks are initially interpolated to uniform along-track reference points (every 172 m) and times (ti) giving the h(xi,ti) used in the RTA solutions. The xi are the cross-track spacings from the reference track and i is the laser campaign index. The adjusted elevation measurements at the along-track reference points are hr(ti) = h(xi,ti) - xi tan(αc) - h0. The hr(ti) time series are averaged over 50 km cells creating H(ti) series and further averaged (weighted by cell area) to H(t) time series over drainage systems (DS), elevation bands, regions, and the entire ice sheet. Temperature-driven changes in the rate of firn compaction, CT(t), are calculated for 50 km cells with our firn-compaction model giving I(t) = H(t) - CT(t) - B(t) where B(t) is the vertical motion of the bedrock. During 2003 to 2009, the average dCT(t)/dt in the accumulation zone is -5 cm/yr, which amounts to a -75 km3/yr correction to ice volume change estimates. The I(t) are especially useful for studying the seasonal cycle of mass gains and losses and interannual variations. The H(t) for the ablation zone are fitted with a multi-variate function with a linear component describing the upward component of ice flow plus winter accumulation (fall through spring) and a portion of a sine function describing the superimposed summer melting. During fall to spring the H(t) indicate that the upward motion of the ice flow is at a rate of 1 m/yr, giving an annual mass gain of 180 Gt/yr in the ablation zone. The summer loss from surface melting in the high-melt summer of 2005 is 350 Gt/yr, giving a net surface loss of 170 Gt/yr from the ablation zone for 2005. During 2003-2008, the H(t) for the ablation zone show accelerations of the mass losses in the northwest DS8 and in the west-central DS7 (including Jacobshavn glacier) and offsetting decelerations of the mass losses in the east-central DS3 and southeast DS4, much of which occurred in 2008 possibly due to an eastward shift in the surface mass balance.

  15. A Review and Proposed Rationale for the use of Ultrasonography as a Diagnostic Modality in the Identification of Bone Stress Injuries.

    PubMed

    Fukushima, Yaeko; Ray, Jeremiah; Kraus, Emily; Syrop, Isaac P; Fredericson, Michael

    2018-04-14

    Bone stress injuries are common in military personnel and athletes. The delayed diagnosis of a bone stress injury can lead to a more severe injury that requires a longer period of treatment. The early detection of bone stress injuries is a central part of management. Currently, the reference standard for detecting bone stress injuries is magnetic resonance imaging. However, the expanding use of point-of-care ultrasonography (US) may enable the early detection of bone stress injuries in the clinical setting. In this article, we review the US detection of bone stress injuries, as well as discuss the rationale for the use of US in the diagnosis of these injuries. © 2018 by the American Institute of Ultrasound in Medicine.

  16. 32 CFR 242.6 - Central point of contact.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 2 2013-07-01 2013-07-01 false Central point of contact. 242.6 Section 242.6 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) MISCELLANEOUS ADMISSION POLICIES AND PROCEDURES FOR THE SCHOOL OF MEDICINE, UNIFORMED SERVICES UNIVERSITY OF THE...

  17. 32 CFR 242.6 - Central point of contact.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Central point of contact. 242.6 Section 242.6 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) MISCELLANEOUS ADMISSION POLICIES AND PROCEDURES FOR THE SCHOOL OF MEDICINE, UNIFORMED SERVICES UNIVERSITY OF THE...

  18. 32 CFR 242.6 - Central point of contact.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 2 2014-07-01 2014-07-01 false Central point of contact. 242.6 Section 242.6 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) MISCELLANEOUS ADMISSION POLICIES AND PROCEDURES FOR THE SCHOOL OF MEDICINE, UNIFORMED SERVICES UNIVERSITY OF THE...

  19. 32 CFR 242.6 - Central point of contact.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 2 2012-07-01 2012-07-01 false Central point of contact. 242.6 Section 242.6 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) MISCELLANEOUS ADMISSION POLICIES AND PROCEDURES FOR THE SCHOOL OF MEDICINE, UNIFORMED SERVICES UNIVERSITY OF THE...

  20. 32 CFR 242.6 - Central point of contact.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 2 2011-07-01 2011-07-01 false Central point of contact. 242.6 Section 242.6 National Defense Department of Defense (Continued) OFFICE OF THE SECRETARY OF DEFENSE (CONTINUED) MISCELLANEOUS ADMISSION POLICIES AND PROCEDURES FOR THE SCHOOL OF MEDICINE, UNIFORMED SERVICES UNIVERSITY OF THE...

  1. Structured perceptual input imposes an egocentric frame of reference-pointing, imagery, and spatial self-consciousness.

    PubMed

    Marcel, Anthony; Dobel, Christian

    2005-01-01

    Perceptual input imposes and maintains an egocentric frame of reference, which enables orientation. When blindfolded, people tended to mistake the assumed intrinsic axes of symmetry of their immediate environment (a room) for their own egocentric relation to features of the room. When asked to point to the door and window, known to be at mid-points of facing (or adjacent) walls, they pointed with their arms at 180 degrees (or 90 degrees) angles, irrespective of where they thought they were in the room. People did the same when requested to imagine the situation. They justified their responses (inappropriately) by logical necessity or a structural description of the room rather than (appropriately) by relative location of themselves and the reference points. In eight experiments, we explored the effect on this in perception and imagery of: perceptual input (without perceptibility of the target reference points); imaging oneself versus another person; aids to explicit spatial self-consciousness; order of questions about self-location; and the relation of targets to the axes of symmetry of the room. The results indicate that, if one is deprived of structured perceptual input, as well as losing one's bearings, (a) one is likely to lose one's egocentric frame of reference itself, and (b) instead of pointing to reference points, one demonstrates their structural relation by adopting the intrinsic axes of the environment as one's own. This is prevented by providing noninformative perceptual input or by inducing subjects to imagine themselves from the outside, which makes explicit the fact of their being located relative to the world. The role of perceptual contact with a structured world is discussed in relation to sensory deprivation and imagery, appeal is made to Gibson's theory of joint egoreception and exteroception, and the data are related to recent theories of spatial memory and navigation.

  2. Rotation and scale invariant shape context registration for remote sensing images with background variations

    NASA Astrophysics Data System (ADS)

    Jiang, Jie; Zhang, Shumei; Cao, Shixiang

    2015-01-01

    Multitemporal remote sensing images generally suffer from background variations, which significantly disrupt traditional region feature and descriptor abstracts, especially between pre and postdisasters, making registration by local features unreliable. Because shapes hold relatively stable information, a rotation and scale invariant shape context based on multiscale edge features is proposed. A multiscale morphological operator is adapted to detect edges of shapes, and an equivalent difference of Gaussian scale space is built to detect local scale invariant feature points along the detected edges. Then, a rotation invariant shape context with improved distance discrimination serves as a feature descriptor. For a distance shape context, a self-adaptive threshold (SAT) distance division coordinate system is proposed, which improves the discriminative property of the feature descriptor in mid-long pixel distances from the central point while maintaining it in shorter ones. To achieve rotation invariance, the magnitude of Fourier transform in one-dimension is applied to calculate angle shape context. Finally, the residual error is evaluated after obtaining thin-plate spline transformation between reference and sensed images. Experimental results demonstrate the robustness, efficiency, and accuracy of this automatic algorithm.

  3. Central intake to improve access to physiotherapy for children with complex needs: a mixed methods case report.

    PubMed

    Wittmeier, Kristy D M; Restall, Gayle; Mulder, Kathy; Dufault, Brenden; Paterson, Marie; Thiessen, Matthew; Lix, Lisa M

    2016-08-31

    Children with complex needs can face barriers to system access and navigation related to their need for multiple services and healthcare providers. Central intake for pediatric rehabilitation was developed and implemented in 2008 in Winnipeg Manitoba Canada as a means to enhance service coordination and access for children and their families. This study evaluates the process and impact of implementing a central intake system, using pediatric physiotherapy as a case example. A mixed methods instrumental case study design was used. Interviews were completed with 9 individuals. Data was transcribed and analyzed for themes. Quantitative data (wait times, referral volume and caregiver satisfaction) was collected for children referred to physiotherapy with complex needs (n = 1399), and a comparison group of children referred for orthopedic concerns (n = 3901). Wait times were analyzed using the Kruskal-Wallis test, caregiver satisfaction was analyzed using Fisher exact test and change point modeling was applied to examine referral volume over the study period. Interview participants described central intake implementation as creating more streamlined processes. Factors that facilitated successful implementation included 1) agreement among stakeholders, 2) hiring of a central intake coordinator, 3) a financial commitment from the government and 4) leadership at the individual and organization level. Mean (sd) wait times improved for children with complex needs (12.3(13.1) to 8.0(6.9) days from referral to contact with family, p < 0.0001; 29.8(17.9) to 24.3(17.0) days from referral to appointment, p < 0.0001) while referral volumes remained consistent. A small but significant increase in wait times was observed for the comparison group (9.6(8.6) to 10.1(6.6) days from referral to contact with family, p < 0.001; 20.4(14.3) to 22.1(13.1) days from referral to appointment, p < 0.0001), accompanied by an increasing referral volume for this group. Caregiver satisfaction remained high throughout the process (p = 0.48). Central intake implementation achieved the intended outcomes of streamlining processes and improving transparency and access to pediatric physiotherapy (i.e., decreasing wait times) for families of children with complex needs. Future research is needed to build on this single discipline case study approach to examine changes in wait times, therapy coordination and stakeholder satisfaction within the context of continuing improvements for pediatric therapy services within the province.

  4. On Deciding How to Decide: To Centralize or Decentralize.

    ERIC Educational Resources Information Center

    Chaffee, Ellen Earle

    Issues concerning whether to centralize or decentralize decision-making are addressed, with applications for colleges. Centralization/decentralization (C/D) must be analyzed with reference to a particular decision. Three components of C/D are locus of authority, breadth of participation, and relative contribution by the decision-maker's staff. C/D…

  5. Increased arterial stiffness in children with congenital heart disease.

    PubMed

    Häcker, Anna-Luisa; Reiner, Barbara; Oberhoffer, Renate; Hager, Alfred; Ewert, Peter; Müller, Jan

    2018-01-01

    Objective Central systolic blood pressure (SBP) is a measure of arterial stiffness and strongly associated with atherosclerosis and end-organ damage. It is a stronger predictor of cardiovascular events and all-cause mortality than peripheral SBP. In particular, for children with congenital heart disease, a higher central SBP might impose a greater threat of cardiac damage. The aim of the study was to analyse and compare central SBP in children with congenital heart disease and in healthy counterparts. Patients and methods Central SBP was measured using an oscillometric method in 417 children (38.9% girls, 13.0 ± 3.2 years) with various congenital heart diseases between July 2014 and February 2017. The test results were compared with a recent healthy reference cohort of 1466 children (49.5% girls, 12.9 ± 2.5 years). Results After correction for several covariates in a general linear model, central SBP of children with congenital heart disease was significantly increased (congenital heart disease: 102.1 ± 10.2 vs. healthy reference cohort: 100.4 ± 8.6, p < .001). The analysis of congenital heart disease subgroups revealed higher central SBP in children with left heart obstructions (mean difference: 3.6 mmHg, p < .001), transpositions of the great arteries after arterial switch (mean difference: 2.2 mmHg, p = .017) and univentricular hearts after total cavopulmonary connection (mean difference: 2.1 mmHg, p = .015) compared with the reference. Conclusion Children with congenital heart disease have significantly higher central SBP compared with healthy peers, predisposing them to premature heart failure. Screening and long-term observations of central SBP in children with congenital heart disease seems warranted in order to evaluate the need for treatment.

  6. Prevalence of and referred pain from myofascial trigger points in the forearm muscles in patients with lateral epicondylalgia.

    PubMed

    Fernández-Carnero, Josué; Fernández-de-Las-Peñas, César; de la Llave-Rincón, Ana Isabel; Ge, Hong-You; Arendt-Nielsen, Lars

    2007-05-01

    Referred pain and pain characteristics evoked from the extensor carpi radialis brevis, extensor carpi radialis longus, extensor digitorum communis, and brachioradialis muscles was investigated in 20 patients with lateral epicondylalgia (LE) and 20-matched controls. Both groups were examined for the presence of myofascial trigger points (TrPs) in a blinded fashion. The quality and location of the evoked referred pain, and the pressure pain threshold (PPT) at the lateral epicondyle on the right upper extremity (symptomatic side in patients, and dominant-side on controls) were recorded. Several lateral elbow pain parameters were also evaluated. Within the patient group, the elicited referred pain by manual exploration of 13 out of 20 (65%) extensor carpi radialis brevis muscles, 12/20 (70%) extensor carpi radialis longus muscles, 10/20 (50%) brachioradialis muscles, and 5/20 (25%) extensor digitorum communis muscles, shares similar pain patterns as their habitual lateral elbow and forearm pain. The mean number of muscles with TrPs for each patient was 2.9 [95% confidence interval (CI) 1,4] of which 2 (95% CI 1,3) were active, and 0.9 (95% CI 0,2) were latent TrPs. Control participants only had latent TrPs (mean: 0.4; 95% CI 0,2). TrP occurrence between the 2 groups was significantly different for active TrPs (P<0.001), but not for latent TrPs (P>0.05). The referred pain pattern was larger in patients than in controls, with pain referral to the lateral epicondyle (proximally) and to the dorso-lateral aspect of the forearm in the patients, and confined to the dorso-lateral aspect of the forearm in the controls. Patients with LE showed a significant (P<0.001) lower PPT (mean: 2.1 kg/cm; 95% CI 0.8, 4 kg/cm) as compared with controls (mean: 4.5 kg/cm; 95% CI 3, 7 kg/cm). Within the patient group, PPT at the lateral epicondyle was negatively correlated with both the total number of TrPs (rs=-0.63; P=0.003) and the number of active TrPs (rs=-0.5; P=0.02): the greater the number of active TrPs, the lower the PPT at the lateral epicondyle. Our results suggest that in patients with LE, the evoked referred pain and its sensory characteristics shared similar patterns as their habitual elbow and forearm pain, consistent with active TrPs. Lower PPT and larger referred pain patterns suggest that peripheral and central sensitization exists in LE.

  7. Joint Processing of Envelope Alignment and Phase Compensation for Isar Imaging

    NASA Astrophysics Data System (ADS)

    Chen, Tao; Jin, Guanghu; Dong, Zhen

    2018-04-01

    Range envelope alignment and phase compensation are spilt into two isolated parts in the classical methods of translational motion compensation in Inverse Synthetic Aperture Radar (ISAR) imaging. In classic method of the rotating object imaging, the two reference points of the envelope alignment and the Phase Difference (PD) estimation are probably not the same point, making it difficult to uncouple the coupling term by conducting the correction of Migration Through Resolution Cell (MTRC). In this paper, an improved approach of joint processing which chooses certain scattering point as the sole reference point is proposed to perform with utilizing the Prominent Point Processing (PPP) method. With this end in view, we firstly get the initial image using classical methods from which a certain scattering point can be chose. The envelope alignment and phase compensation using the selected scattering point as the same reference point are subsequently conducted. The keystone transform is thus smoothly applied to further improve imaging quality. Both simulation experiments and real data processing are provided to demonstrate the performance of the proposed method compared with classical method.

  8. Comparing theories of reference-dependent choice.

    PubMed

    Bhatia, Sudeep

    2017-09-01

    Preferences are influenced by the presence or absence of salient choice options, known as reference points. This behavioral tendency is traditionally attributed to the loss aversion and diminishing sensitivity assumptions of prospect theory. In contrast, some psychological research suggests that reference dependence is caused by attentional biases that increase the subjective weighting of the reference point's primary attributes. Although both theories are able to successfully account for behavioral findings involving reference dependence, this article shows that these theories make diverging choice predictions when available options are inferior to the reference point. It presents the results of 2 studies that use settings with inferior choice options to compare these 2 theories. The analysis involves quantitative fits to participant-level choice data, and the results indicate that most participants are better described by models with attentional bias than they are by models with loss aversion and diminishing sensitivity. These differences appear to be caused by violations of loss aversion and diminishing sensitivity in losses. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Pressure-Drop Considerations in the Characterization of Dew-Point Transfer Standards at High Temperatures

    NASA Astrophysics Data System (ADS)

    Mitter, H.; Böse, N.; Benyon, R.; Vicente, T.

    2012-09-01

    During calibration of precision optical dew-point hygrometers (DPHs), it is usually necessary to take into account the pressure drop induced by the gas flow between the "point of reference" and the "point of use" (mirror or measuring head of the DPH) either as a correction of the reference dew-point temperature or as part of the uncertainty estimation. At dew-point temperatures in the range of ambient temperature and below, it is sufficient to determine the pressure drop for the required gas flow, and to keep the volumetric flow constant during the measurements. In this case, it is feasible to keep the dry-gas flow into the dew-point generator constant or to measure the flow downstream the DPH at ambient temperature. In normal operation, at least one DPH in addition to the monitoring DPH are used, and this operation has to be applied to each instrument. The situation is different at high dew-point temperatures up to 95 °C, the currently achievable upper limit reported in this paper. With increasing dew-point temperatures, the reference gas contains increasing amounts of water vapour and a constant dry-gas flow will lead to a significant enhanced volume flow at the conditions at the point of use, and therefore, to a significantly varying pressure drop depending on the applied dew-point temperature. At dew-point temperatures above ambient temperature, it is also necessary to heat the reference gas and the mirror head of the DPH sufficiently to avoid condensation which will additionally increase the volume flow and the pressure drop. In this paper, a method is provided to calculate the dry-gas flow rate needed to maintain a known wet-gas flow rate through a chilled mirror for a range of temperature and pressures.

  10. Construction and validation of the midsagittal reference plane based on the skull base symmetry for three-dimensional cephalometric craniofacial analysis.

    PubMed

    Kim, Hak-Jin; Kim, Bong Chul; Kim, Jin-Geun; Zhengguo, Piao; Kang, Sang Hoon; Lee, Sang-Hwy

    2014-03-01

    The objective of this study was to determine the reliable midsagittal (MS) reference plane in practical ways for the three-dimensional craniofacial analysis on three-dimensional computed tomography images. Five normal human dry skulls and 20 normal subjects without any dysmorphoses or asymmetries were used. The accuracies and stability on repeated plane construction for almost every possible candidate MS plane based on the skull base structures were examined by comparing the discrepancies in distances and orientations from the reference points and planes of the skull base and facial bones on three-dimensional computed tomography images. The following reference points of these planes were stable, and their distribution was balanced: nasion and foramen cecum at the anterior part of the skull base, sella at the middle part, and basion and opisthion at the posterior part. The candidate reference planes constructed using the aforementioned reference points were thought to be reliable for use as an MS reference plane for the three-dimensional analysis of maxillofacial dysmorphosis.

  11. Mapping the vestibular evoked myogenic potential (VEMP).

    PubMed

    Colebatch, James G

    2012-01-01

    Effects of different electrode placements and indifferent electrodes were investigated for the vestibular evoked myogenic potential (VEMP) recorded from the sternocleidomastoid muscle (SCM). In 5 normal volunteers, the motor point of the left SCM was identified and an electrode placed there. A grid of 7 additional electrodes was laid out, along and across the SCM, based upon the location of the motor point. One reference electrode was placed over the sternoclavicular joint and another over C7. There were clear morphological changes with differing recording sites and for the two reference electrodes, but the earliest and largest responses were recorded from the motor point. The C7 reference affected the level of rectified EMG and was associated with an initial negativity in some electrodes. The latencies of the p13 potentials increased with distance from the motor point but the n23 latencies did not. Thus the p13 potential behaved as a travelling wave whereas the n23 behaved as a standing wave. The C7 reference may be contaminated by other evoked myogenic activity. Ideally recordings should be made with an active electrode over the motor point.

  12. Automation of the Image Analysis for Thermographic Inspection

    NASA Technical Reports Server (NTRS)

    Plotnikov, Yuri A.; Winfree, William P.

    1998-01-01

    Several data processing procedures for the pulse thermal inspection require preliminary determination of an unflawed region. Typically, an initial analysis of the thermal images is performed by an operator to determine the locations of unflawed and the defective areas. In the present work an algorithm is developed for automatically determining a reference point corresponding to an unflawed region. Results are obtained for defects which are arbitrarily located in the inspection region. A comparison is presented of the distributions of derived values with right and wrong localization of the reference point. Different algorithms of automatic determination of the reference point are compared.

  13. Local sensitivity of per-recruit fishing mortality reference points.

    PubMed

    Cadigan, N G; Wang, S

    2016-12-01

    We study the sensitivity of fishery management per-recruit harvest rates which may be part of a quantitative harvest strategy designed to achieve some objective for catch or population size. We use a local influence sensitivity analysis to derive equations that describe how these reference harvest rates are affected by perturbations to productivity processes. These equations give a basic theoretical understanding of sensitivity that can be used to predict what the likely impacts of future changes in productivity will be. Our results indicate that per-recruit reference harvest rates are more sensitive to perturbations when the equilibrium catch or population size per recruit, as functions of the harvest rate, have less curvature near the reference point. Overall our results suggest that per recruit reference points will, with some exceptions, usually increase if (1) growth rates increase, (2) natural mortality rates increase, or (3) fishery selectivity increases to an older age.

  14. Subacute combined degeneration

    MedlinePlus

    ... SCD Images Central nervous system and peripheral nervous system Central nervous system References Pytel P, Anthony DC. Peripheral nerves and ... chap 27. So YT. Deficiency diseases of the nervous system. In: Daroff RB, Jankovic J, Mazziotta JC, Pomeroy ...

  15. [The centralized mycobacteriological laboratory is a necessary component of a phthisiological service in large towns of Russia].

    PubMed

    Dorozhkova, I R; Freĭman, G E; Moroz, A M

    2007-01-01

    The paper presents the main points of the authors' own concept of the centralization of mycobacteriological service in large towns of the Russian Federation. The main points of step-by-step organizational and methodological measures required to solve this problem are described in detail. Consecutive measures to realize the proposed mycobacteriological service centralization model originated in January 2004 on a model of the Moscow Eastern Administrative District with 1380 thousand inhabitants are described.

  16. Model reference adaptive control for the azimuth-pointing system of a balloon-borne stabilized platform

    NASA Technical Reports Server (NTRS)

    Lubin, Philip M.; Tomizuka, Masayoshi; Chingcuanco, Alfredo O.; Meinhold, Peter R.

    1991-01-01

    A balloon-born stabilized platform has been developed for the remotely operated altitude-azimuth pointing of a millimeter wave telescope system. This paper presents a development and implementation of model reference adaptive control (MRAC) for the azimuth-pointing system of the stabilized platform. The primary goal of the controller is to achieve pointing rms better than 0.1 deg. Simulation results indicate that MRAC can achieve pointing rms better than 0.1 deg. Ground test results show pointing rms better than 0.03 deg. Data from the first flight at the National Scientific Balloon Facility (NSBF) Palestine, Texas show pointing rms better than 0.02 deg.

  17. Whether a Building or a State of Mind, the Central Office Must Evolve

    ERIC Educational Resources Information Center

    Mizell, Hayes

    2010-01-01

    The central office is both a physical place and a state of mind. In some school systems, the central office is a separate building located away from schools. In other communities, the office is housed in one of the school buildings. When someone mentions "central office," they may not be referring only to the building. They may also mean the tip…

  18. High accuracy attitude reference stabilization and pointing using the Teledyne SDG-5 gyro and the DRIRU II inertial reference unit

    NASA Astrophysics Data System (ADS)

    Green, K. N.; van Alstine, R. L.

    This paper presents the current performance levels of the SDG-5 gyro, a high performance two-axis dynamically tuned gyro, and the DRIRU II redundant inertial reference unit relating to stabilization and pointing applications. Also presented is a discussion of a product improvement program aimed at further noise reductions to meet the demanding requirements of future space defense applications.

  19. Wollaston prism phase-stepping point diffraction interferometer and method

    DOEpatents

    Rushford, Michael C.

    2004-10-12

    A Wollaston prism phase-stepping point diffraction interferometer for testing a test optic. The Wollaston prism shears light into reference and signal beams, and provides phase stepping at increased accuracy by translating the Wollaston prism in a lateral direction with respect to the optical path. The reference beam produced by the Wollaston prism is directed through a pinhole of a diaphragm to produce a perfect spherical reference wave. The spherical reference wave is recombined with the signal beam to produce an interference fringe pattern of greater accuracy.

  20. Centralization and Decentralization: An International Viewpoint on an American Dilemma. A Special CASEA Report.

    ERIC Educational Resources Information Center

    Walker, William G.

    This report outlines the history of the centralization-decentralization dilemma in the goverance of organizations, discusses two types of centralization-decentralization continua, and suggests further research. The first type of continuum discussed -- the traditional American -- refers to decisionmaking in the areas of public debate and partisan…

  1. The Central Hardwood Forest: its boundaries and physiographic provinces

    Treesearch

    James S. Fralish

    2003-01-01

    The Central Hardwood Forest (CHF) refers to the area where deciduous hardwood species overwhelmingly, but not exclusively, dominate the stands and cover types that occur as repeating units across the landscape. Transition zones where Central Hardwood species mix with species from adjacent regions identify boundaries of the region. These regions are the Northern...

  2. The Central Hardwood Forest: Its Boundaries and Physiographic Provinces

    Treesearch

    James S. Fralish

    2003-01-01

    The Central Hardwood Forest (CHF) refers to the area where deciduous hardwood species overwhelmingly, but not exclusively, dominate the stands and cover types that occur as repeating units across the landscape. Transition zones where Central Hardwood species mix with species from adjacent regions identify boundaries of the region. These regions are the Northern...

  3. The Unicellular State as a Point Source in a Quantum Biological System

    PubMed Central

    Torday, John S.; Miller, William B.

    2016-01-01

    A point source is the central and most important point or place for any group of cohering phenomena. Evolutionary development presumes that biological processes are sequentially linked, but neither directed from, nor centralized within, any specific biologic structure or stage. However, such an epigenomic entity exists and its transforming effects can be understood through the obligatory recapitulation of all eukaryotic lifeforms through a zygotic unicellular phase. This requisite biological conjunction can now be properly assessed as the focal point of reconciliation between biology and quantum phenomena, illustrated by deconvoluting complex physiologic traits back to their unicellular origins. PMID:27240413

  4. Earthquake effect on volcano and the geological structure in central java using tomography travel time method and relocation hypocenter by grid search method

    NASA Astrophysics Data System (ADS)

    Suharsono; Nurdian, S. W.; Palupi, I. R.

    2016-11-01

    Relocating hypocenter is a way to improve the velocity model of the subsurface. One of the method is Grid Search. To perform the distribution of the velocity in subsurface by tomography method, it is used the result of relocating hypocenter to be a reference for subsurface analysis in volcanic and major structural patterns, such as in Central Java. The main data of this study is the earthquake data recorded from 1952 to 2012 with the P wave number is 9162, the number of events is 2426 were recorded by 30 stations located in the vicinity of Central Java. Grid search method has some advantages they are: it can relocate the hypocenter more accurate because this method is dividing space lattice model into blocks, and each grid block can only be occupied by one point hypocenter. Tomography technique is done by travel time data that has had relocated with inversion pseudo bending method. Grid search relocated method show that the hypocenter's depth is shallower than before and the direction is to the south, the hypocenter distribution is modeled into the subduction zone between the continent of Eurasia with the Indo-Australian with an average angle of 14 °. The tomography results show the low velocity value is contained under volcanoes with value of -8% to -10%, then the pattern of the main fault structure in Central Java can be description by the results of tomography at high velocity that is from 8% to 10% with the direction is northwest and northeast-southwest.

  5. An Indoor Positioning Technique Based on a Feed-Forward Artificial Neural Network Using Levenberg-Marquardt Learning Method

    NASA Astrophysics Data System (ADS)

    Pahlavani, P.; Gholami, A.; Azimi, S.

    2017-09-01

    This paper presents an indoor positioning technique based on a multi-layer feed-forward (MLFF) artificial neural networks (ANN). Most of the indoor received signal strength (RSS)-based WLAN positioning systems use the fingerprinting technique that can be divided into two phases: the offline (calibration) phase and the online (estimation) phase. In this paper, RSSs were collected for all references points in four directions and two periods of time (Morning and Evening). Hence, RSS readings were sampled at a regular time interval and specific orientation at each reference point. The proposed ANN based model used Levenberg-Marquardt algorithm for learning and fitting the network to the training data. This RSS readings in all references points and the known position of these references points was prepared for training phase of the proposed MLFF neural network. Eventually, the average positioning error for this network using 30% check and validation data was computed approximately 2.20 meter.

  6. Genetics Home Reference: lymphedema-distichiasis syndrome

    MedlinePlus

    ... on PubMed or Free article on PubMed Central Erickson RP, Dagenais SL, Caulder MS, Downs CA, Herman ... article on PubMed Central Fang J, Dagenais SL, Erickson RP, Arlt MF, Glynn MW, Gorski JL, Seaver ...

  7. Robust iterative closest point algorithm based on global reference point for rotation invariant registration.

    PubMed

    Du, Shaoyi; Xu, Yiting; Wan, Teng; Hu, Huaizhong; Zhang, Sirui; Xu, Guanglin; Zhang, Xuetao

    2017-01-01

    The iterative closest point (ICP) algorithm is efficient and accurate for rigid registration but it needs the good initial parameters. It is easily failed when the rotation angle between two point sets is large. To deal with this problem, a new objective function is proposed by introducing a rotation invariant feature based on the Euclidean distance between each point and a global reference point, where the global reference point is a rotation invariant. After that, this optimization problem is solved by a variant of ICP algorithm, which is an iterative method. Firstly, the accurate correspondence is established by using the weighted rotation invariant feature distance and position distance together. Secondly, the rigid transformation is solved by the singular value decomposition method. Thirdly, the weight is adjusted to control the relative contribution of the positions and features. Finally this new algorithm accomplishes the registration by a coarse-to-fine way whatever the initial rotation angle is, which is demonstrated to converge monotonically. The experimental results validate that the proposed algorithm is more accurate and robust compared with the original ICP algorithm.

  8. Robust iterative closest point algorithm based on global reference point for rotation invariant registration

    PubMed Central

    Du, Shaoyi; Xu, Yiting; Wan, Teng; Zhang, Sirui; Xu, Guanglin; Zhang, Xuetao

    2017-01-01

    The iterative closest point (ICP) algorithm is efficient and accurate for rigid registration but it needs the good initial parameters. It is easily failed when the rotation angle between two point sets is large. To deal with this problem, a new objective function is proposed by introducing a rotation invariant feature based on the Euclidean distance between each point and a global reference point, where the global reference point is a rotation invariant. After that, this optimization problem is solved by a variant of ICP algorithm, which is an iterative method. Firstly, the accurate correspondence is established by using the weighted rotation invariant feature distance and position distance together. Secondly, the rigid transformation is solved by the singular value decomposition method. Thirdly, the weight is adjusted to control the relative contribution of the positions and features. Finally this new algorithm accomplishes the registration by a coarse-to-fine way whatever the initial rotation angle is, which is demonstrated to converge monotonically. The experimental results validate that the proposed algorithm is more accurate and robust compared with the original ICP algorithm. PMID:29176780

  9. Restored agricultural wetlands in Central Iowa: habitat quality and amphibian response

    USGS Publications Warehouse

    Reeves, Rebecca A.; Pierce, Clay; Smalling, Kelly L.; Klaver, Robert W.; Vandever, Mark W.; Battaglin, William A.; Muths, Erin L.

    2016-01-01

    Amphibians are declining throughout the United States and worldwide due, partly, to habitat loss. Conservation practices on the landscape restore wetlands to denitrify tile drainage effluent and restore ecosystem services. Understanding how water quality, hydroperiod, predation, and disease affect amphibians in restored wetlands is central to maintaining healthy amphibian populations in the region. We examined the quality of amphibian habitat in restored wetlands relative to reference wetlands by comparing species richness, developmental stress, and adult leopard frog (Lithobates pipiens) survival probabilities to a suite of environmental metrics. Although measured habitat variables differed between restored and reference wetlands, differences appeared to have sub-lethal rather than lethal effects on resident amphibian populations. There were few differences in amphibian species richness and no difference in estimated survival probabilities between wetland types. Restored wetlands had more nitrate and alkaline pH, longer hydroperiods, and were deeper, whereas reference wetlands had more amphibian chytrid fungus zoospores in water samples and resident amphibians exhibited increased developmental stress. Restored and reference wetlands are both important components of the landscape in central Iowa and maintaining a complex of fish-free wetlands with a variety of hydroperiods will likely contribute to the persistence of amphibians in this landscape.

  10. Preset pivotal tool holder

    DOEpatents

    Asmanes, Charles

    1979-01-01

    A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.

  11. Can prospect theory explain risk-seeking behavior by terminally ill patients?

    PubMed

    Rasiel, Emma B; Weinfurt, Kevin P; Schulman, Kevin A

    2005-01-01

    Patients with life-threatening conditions sometimes appear to make risky treatment decisions as their condition declines, contradicting the risk-averse behavior predicted by expected utility theory. Prospect theory accommodates such decisions by describing how individuals evaluate outcomes relative to a reference point and how they exhibit risk-seeking behavior over losses relative to that point. The authors show that a patient's reference point for his or her health is a key factor in determining which treatment option the patient selects, and they examine under what circumstances the more risky option is selected. The authors argue that patients' reference points may take time to adjust following a change in diagnosis, with implications for predicting under what circumstances a patient may select experimental or conventional therapies or select no treatment.

  12. Anti-emetic mechanisms of Zingiber officinale against cisplatin induced emesis in the pigeon; behavioral and neurochemical correlates.

    PubMed

    Ullah, Ihsan; Subhan, Fazal; Ayaz, Muhammad; Shah, Rehmat; Ali, Gowhar; Haq, Ikram Ul; Ullah, Sami

    2015-02-26

    Zingiber officinale (ZO, family Zingiberaceae) has been reported for its antiemetic activity against cancer chemotherapy induced emesis in animal models and in clinics. Current study was designed to investigate ZO for potential usefulness against cisplatin induced vomiting in pigeon and its effects on central and peripheral neurotransmitters involved in the act of vomiting. Zingiber officinale acetone fraction (ZO-ActFr) was investigated for attenuation of emesis induced by cisplatin in healthy pigeons. Neurotransmitters DA, 5HT and their metabolites DOPAC, HVA and 5HIAA were analyzed using High Performance Liquid Chromatography system coupled with electrochemical detector in area postrema, brain stem and intestine. Antiemetic effect of ZO-ActFr was correlated with central and intestinal neurotransmitters levels in pigeon. Cisplatin (7 mg/kg i.v.) induced emesis without lethality upto the observation period. ZO-ActFr (25, 50 & 100 mg/kg) attenuated cisplatin induced emesis ~ 44.18%, 58.13% (P < 0.05) and 27.9%, respectively; the reference drug, metoclopramide (MCP; 30 mg/kg), produced ~ 48.83% reduction (P < 0.05). ZO-ActFr reduced (P < 0.05 - 0.001) 5-hydroxytryptamine (5HT) concentration in the area postrema, brain stem and intestine at 3(rd) hour of cisplatin administration, while at the 18(th) hour ZO treatments attenuated the dopamine upsurge (P < 0.001) caused by cisplatin in the area postrema and 5HT concentration (P < 0.01 - 0.001) in the brain stem and intestine. ZO treatments alone did not altered the basal neurotransmitters and their metabolites in the brain areas and intestine. The behavioral study verify the antiemetic profile of ZO against cisplatin induced emesis in the pigeon, where central and peripheral neural evidences advocate the involvement of serotonergic mechanism at initial time point (3(rd) hr), while the later time point (18(th) hr) is associated with serotonergic and dopaminergic component in the mediation of its antiemetic effect.

  13. EULAR-PReS points to consider for the use of imaging in the diagnosis and management of juvenile idiopathic arthritis in clinical practice.

    PubMed

    Colebatch-Bourn, A N; Edwards, C J; Collado, P; D'Agostino, M-A; Hemke, R; Jousse-Joulin, S; Maas, M; Martini, A; Naredo, E; Østergaard, M; Rooney, M; Tzaribachev, N; van Rossum, M A; Vojinovic, J; Conaghan, P G; Malattia, C

    2015-11-01

    To develop evidence based points to consider the use of imaging in the diagnosis and management of juvenile idiopathic arthritis (JIA) in clinical practice. The task force comprised a group of paediatric rheumatologists, rheumatologists experienced in imaging, radiologists, methodologists and patients from nine countries. Eleven questions on imaging in JIA were generated using a process of discussion and consensus. Research evidence was searched systematically for each question using MEDLINE, EMBASE and Cochrane CENTRAL. Imaging modalities included were conventional radiography, ultrasound, MRI, CT, scintigraphy and positron emission tomography. The experts used the evidence obtained from the relevant studies to develop a set of points to consider. The level of agreement with each point to consider was assessed using a numerical rating scale. A total of 13 277 references were identified from the search process, from which 204 studies were included in the systematic review. Nine points to consider were produced, taking into account the heterogeneity of JIA, the lack of normative data and consequent difficulty identifying pathology. These encompassed the role of imaging in making a diagnosis of JIA, detecting and monitoring inflammation and damage, predicting outcome and response to treatment, use of guided therapies, progression and remission. Level of agreement for each proposition varied according to the research evidence and expert opinion. Nine points to consider and a related research agenda for the role of imaging in the management of JIA were developed using published evidence and expert opinion. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Leave or Stay as a Risky Choice: Effects of Salary Reference Points and Anchors on Turnover Intention

    PubMed Central

    Xiong, Guanxing; Wang, X. T.; Li, Aimei

    2018-01-01

    Within a risky choice framework, we examine how multiple reference points and anchors regulate pay perception and turnover intentions in real organizational contexts with actual employees. We hypothesize that the salary range is psychologically demarcated by three reference points into four regions, the minimum requirement (MR), the status quo (SQ), and the goal (G). Three studies were conducted: Study 1 analyzed the relationship between turnover intention and the subjective likelihood of falling into each of four expected salary regions; Study 2 tested the mediating effect of pay satisfaction on salary reference point-dependent turnover intention; and Study 3 explored the anchoring effect of estimated peer salaries. The results show that turnover intention was higher in the region below MR or between SQ and G but lower in the region above G or between MR and SQ. That is, turnover intention can be high even in situations of salary raise, if the raise is below a salary goal (i.e., leaving for a lack of opportunity) and low even in situations of salary loss, if the expected salary is still above the MR (i.e., staying for security). In addition, turnover intention was regulated by pay satisfaction and peer salaries. In conclusion, turnover intention can be viewed as a risky choice adapted to salary reference points. PMID:29872409

  15. Assessing the accuracy of TDR-based water leak detection system

    NASA Astrophysics Data System (ADS)

    Fatemi Aghda, S. M.; GanjaliPour, K.; Nabiollahi, K.

    2018-03-01

    The use of TDR system to detect leakage locations in underground pipes has been developed in recent years. In this system, a bi-wire is installed in parallel with the underground pipes and is considered as a TDR sensor. This approach greatly covers the limitations arisen with using the traditional method of acoustic leak positioning. TDR based leak detection method is relatively accurate when the TDR sensor is in contact with water in just one point. Researchers have been working to improve the accuracy of this method in recent years. In this study, the ability of TDR method was evaluated in terms of the appearance of multi leakage points simultaneously. For this purpose, several laboratory tests were conducted. In these tests in order to simulate leakage points, the TDR sensor was put in contact with water at some points, then the number and the dimension of the simulated leakage points were gradually increased. The results showed that with the increase in the number and dimension of the leakage points, the error rate of the TDR-based water leak detection system increases. The authors tried, according to the results obtained from the laboratory tests, to develop a method to improve the accuracy of the TDR-based leak detection systems. To do that, they defined a few reference points on the TDR sensor. These points were created via increasing the distance between two conductors of TDR sensor and were easily identifiable in the TDR waveform. The tests were repeated again using the TDR sensor having reference points. In order to calculate the exact distance of the leakage point, the authors developed an equation in accordance to the reference points. A comparison between the results obtained from both tests (with and without reference points) showed that using the method and equation developed by the authors can significantly improve the accuracy of positioning the leakage points.

  16. Point-of-Care Virologic Testing to Improve Outcomes of HIV-Infected Children in Zambia: A Clinical Trial Protocol.

    PubMed

    Chibwesha, Carla J; Ford, Catherine E; Mollan, Katie R; Stringer, Jeffrey S A

    2016-08-01

    In the absence of early infant diagnosis (EID) and immediate antiretroviral therapy (ART), some 50% of untreated HIV-infected infants die before age 2. Conventional EID requires sophisticated instruments that are typically placed in centralized or reference laboratories. In low-resource settings, centralized systems often lead to result turnaround times of several months, long delays in diagnosis, and adverse outcomes for HIV-infected children. Our clinical trial tests the effectiveness of a new point-of-care (POC) diagnostic technology to identify HIV-infected infants and start providing them life-saving ART as soon as possible. The study uses a randomized, controlled design to test whether the Alere q platform for HIV DNA polymerase chain reaction (PCR) testing improves outcomes of HIV-infected children in Zambia. We aim to enroll 2867 HIV-exposed infants aged 4-12 weeks and to follow those who are HIV infected for 12 months as they receive HIV care at 6 public health facilities in Lusaka. The trial's primary endpoint is the proportion of HIV-infected infants in each study arm who start ART and remain alive, in care, and virally suppressed 12 months after their diagnostic blood draw. Our trial will provide evidence for the incremental benefit of implementing a POC EID strategy in low-resource settings where only off-site PCR services are currently available. The results will be useful in guiding future decisions regarding investments in POC virologic testing as part of overall pediatric AIDS mitigation strategies in sub-Saharan Africa. clinicaltrials.gov NCT02682810.

  17. Nutritional condition and serum biochemistry for free-living Swainson's Hawks wintering in central Argentina.

    PubMed

    Sarasola, José Hernán; Negro, Juan José; Travaini, Alejandro

    2004-04-01

    We assessed the nutritional condition and established reference values for serum chemistry parameters in a long distance migrant bird of prey, the Swainson's Hawk (Buteo swainsoni), wintering in central Argentina. We analyzed serum concentration of urea, uric acid, cholesterol, and triglycerides and assessed age and sex related differences in these parameters. A body condition index was obtained from the resultant residuals of the regression of body mass and a morphometric measure. No statistical differences were observed among sex and age groups for urea, uric acid and triglyceride serum concentration. However, cholesterol concentration differed among male and female hawks, which could be related to the gain of body mass in wintering grounds at differential rates. The mean values of the four parameters were in the range of those recorded in the Common Buzzard (Buteo buteo), indicating good nutritional condition of the population we studied. Forearm length was the morphometric variable that better correlated with body mass. The resultant body condition index was only correlated with triglyceride concentration, suggesting that this index could be valuable in future work dealing with the assessment of body fat storage in wintering and breeding hawks, as well as in stopover points on the migratory route.

  18. The Human Central Pattern Generator for Locomotion.

    PubMed

    Minassian, Karen; Hofstoetter, Ursula S; Dzeladini, Florin; Guertin, Pierre A; Ijspeert, Auke

    2017-03-01

    The ability of dedicated spinal circuits, referred to as central pattern generators (CPGs), to produce the basic rhythm and neural activation patterns underlying locomotion can be demonstrated under specific experimental conditions in reduced animal preparations. The existence of CPGs in humans is a matter of debate. Equally elusive is the contribution of CPGs to normal bipedal locomotion. To address these points, we focus on human studies that utilized spinal cord stimulation or pharmacological neuromodulation to generate rhythmic activity in individuals with spinal cord injury, and on neuromechanical modeling of human locomotion. In the absence of volitional motor control and step-specific sensory feedback, the human lumbar spinal cord can produce rhythmic muscle activation patterns that closely resemble CPG-induced neural activity of the isolated animal spinal cord. In this sense, CPGs in humans can be defined by the activity they produce. During normal locomotion, CPGs could contribute to the activation patterns during specific phases of the step cycle and simplify supraspinal control of step cycle frequency as a feedforward component to achieve a targeted speed. Determining how the human CPGs operate will be essential to advance the theory of neural control of locomotion and develop new locomotor neurorehabilitation paradigms.

  19. Genetics Home Reference: central precocious puberty

    MedlinePlus

    ... girls and between ages 9 and 14 in boys, girls with central precocious puberty begin exhibiting signs before ... of puberty is even earlier than normal in girls than in boys. Boys with an MKRN3 gene mutation inherited from ...

  20. Genetics Home Reference: congenital central hypoventilation syndrome

    MedlinePlus

    ... M, Stevens CA, Berry-Kravis EM, Weese-Mayer DE. PHOX2B mutation-confirmed congenital central hypoventilation syndrome: presentation ... on PubMed Axelrod FB, Chelimsky GG, Weese-Mayer DE. Pediatric autonomic disorders. Pediatrics. 2006 Jul;118(1): ...

  1. Index to limnological data for southcentral Alaska Lakes

    USGS Publications Warehouse

    Maurer, M.A.; Woods, P.F.

    1987-01-01

    South-central Alaska lakes are a valuable natural resource and provide a variety of recreational opportunities to the public. Lakeside development has increased significantly in the past 10 years and several south-central Alaskan lakes have documented pollution problems. Cultural eutrophication, the process by which man-induced nutrient loading to a lake results in large increases in biological productivity, can also produce noxious algae blooms, dissolved oxygen depletion at depth, reduced water transparency, and fish kills. The potential for cultural eutrophication of south-central Alaska lakes prompted the U.S. Geological Survey (USGS) Water Resources Division and the Alaska Department of Natural Resources-Division of Geological and Geophysical Surveys (ADGGS) to provide lake researchers, managers, and the public with this index of published historical and current limnological references. The purpose of the index is to provide reference to the data which can be used to identify and monitor cultural eutrophication of south-central Alaska lakes. (Lantz-PTT)

  2. Spatial Updating Strategy Affects the Reference Frame in Path Integration.

    PubMed

    He, Qiliang; McNamara, Timothy P

    2018-06-01

    This study investigated how spatial updating strategies affected the selection of reference frames in path integration. Participants walked an outbound path consisting of three successive waypoints in a featureless environment and then pointed to the first waypoint. We manipulated the alignment of participants' final heading at the end of the outbound path with their initial heading to examine the adopted reference frame. We assumed that the initial heading defined the principal reference direction in an allocentric reference frame. In Experiment 1, participants were instructed to use a configural updating strategy and to monitor the shape of the outbound path while they walked it. Pointing performance was best when the final heading was aligned with the initial heading, indicating the use of an allocentric reference frame. In Experiment 2, participants were instructed to use a continuous updating strategy and to keep track of the location of the first waypoint while walking the outbound path. Pointing performance was equivalent regardless of the alignment between the final and the initial headings, indicating the use of an egocentric reference frame. These results confirmed that people could employ different spatial updating strategies in path integration (Wiener, Berthoz, & Wolbers Experimental Brain Research 208(1) 61-71, 2011), and suggested that these strategies could affect the selection of the reference frame for path integration.

  3. Bayesian Probability Theory

    NASA Astrophysics Data System (ADS)

    von der Linden, Wolfgang; Dose, Volker; von Toussaint, Udo

    2014-06-01

    Preface; Part I. Introduction: 1. The meaning of probability; 2. Basic definitions; 3. Bayesian inference; 4. Combinatrics; 5. Random walks; 6. Limit theorems; 7. Continuous distributions; 8. The central limit theorem; 9. Poisson processes and waiting times; Part II. Assigning Probabilities: 10. Transformation invariance; 11. Maximum entropy; 12. Qualified maximum entropy; 13. Global smoothness; Part III. Parameter Estimation: 14. Bayesian parameter estimation; 15. Frequentist parameter estimation; 16. The Cramer-Rao inequality; Part IV. Testing Hypotheses: 17. The Bayesian way; 18. The frequentist way; 19. Sampling distributions; 20. Bayesian vs frequentist hypothesis tests; Part V. Real World Applications: 21. Regression; 22. Inconsistent data; 23. Unrecognized signal contributions; 24. Change point problems; 25. Function estimation; 26. Integral equations; 27. Model selection; 28. Bayesian experimental design; Part VI. Probabilistic Numerical Techniques: 29. Numerical integration; 30. Monte Carlo methods; 31. Nested sampling; Appendixes; References; Index.

  4. ORCA: measuring the neutrino mass hierarchy with atmospheric neutrinos in the Mediterranean

    NASA Astrophysics Data System (ADS)

    Van Elewyck, Véronique; KM3NeT Collaboration

    2015-04-01

    Since the measurement of the mixing angle θ13, the determination of the neutrino mass hierarchy has become a central challenge of neutrino physics. Recent studies have pointed out that it could reveal itself in the atmospheric neutrino sector, where oscillations are affected by Earth matter effects. This contribution reports on the ORCA feasibility study for such a measurement with an underwater Cherenkov detector based on the technology developed for the KM3NeT neutrino telescope. The baseline performances are discussed for a reference detector with 50 instrumented lines. Preliminary projections, based on the muon channel only, indicate that a 3 — 5σ significance measurement is within reach of a detector with an exposure of the order of 20 Mton years. Further improvement is expected to come from the electron channel, which is currently under study.

  5. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    PubMed

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p < 0.000). Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p < 0.000). When categorizing CPP as binary endpoint, 18.8% of values were identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  6. Mechanisms of thermal acclimation to exercise and heat

    NASA Technical Reports Server (NTRS)

    Nadel, E. R.; Pandolf, K. B.; Roberts, M. F.; Stolwijk, J. A. J.

    1974-01-01

    By plotting local sweating rate from a given area against the central sweating drive (which is analogous to esophageal temperature, when mean skin temperature is constant), it is possible to determine the characteristic gain constant of that area as well as its point of zero central drive. An increase in the gain constant as a result of acclimation would indicate an increased sensitivity of the sweating mechanism per unit of central sweating drive, i.e., enhanced peripheral sensitivity. A displacement of the point of zero central drive as a result of acclimation would indicate that central mechanisms are responsible for the heightened sweating response. The study was undertaken to provide information about whether central or peripheral physiological mechanisms provide for increased sweating capabilities during acclimation, and about whether the increased sweating capabilities in heat acclimation and physical training are provided for by the same mechanisms.

  7. Nonimaging optical illumination system

    DOEpatents

    Winston, R.; Ries, H.

    1996-12-17

    A nonimaging illumination optical device for producing a selected far field illuminance over an angular range. The optical device includes a light source, a light reflecting surface, and a family of light edge rays defined along a reference line with the reflecting surface defined in terms of the reference line as a parametric function R(t) where t is a scalar parameter position and R(t)=k(t)+Du(t) where k(t) is a parameterization of the reference line, and D is a distance from a point on the reference line to the reflection surface along the desired edge ray through the point. 35 figs.

  8. Nonimaging optical illumination system

    DOEpatents

    Winston, R.; Ries, H.

    1998-10-06

    A nonimaging illumination optical device for producing a selected far field illuminance over an angular range. The optical device includes a light source a light reflecting surface, and a family of light edge rays defined along a reference line with the reflecting surface defined in terms of the reference lines a parametric function R(t) where t is a scalar parameter position and R(t)=k(t)+Du(t) where k(t) is a parameterization of the reference line, and D is a distance from a point on the reference line to the reflection surface along the desired edge ray through the point. 35 figs.

  9. Sharing reference data and including cows in the reference population improve genomic predictions in Danish Jersey.

    PubMed

    Su, G; Ma, P; Nielsen, U S; Aamand, G P; Wiggans, G; Guldbrandtsen, B; Lund, M S

    2016-06-01

    Small reference populations limit the accuracy of genomic prediction in numerically small breeds, such like Danish Jersey. The objective of this study was to investigate two approaches to improve genomic prediction by increasing size of reference population in Danish Jersey. The first approach was to include North American Jersey bulls in Danish Jersey reference population. The second was to genotype cows and use them as reference animals. The validation of genomic prediction was carried out on bulls and cows, respectively. In validation on bulls, about 300 Danish bulls (depending on traits) born in 2005 and later were used as validation data, and the reference populations were: (1) about 1050 Danish bulls, (2) about 1050 Danish bulls and about 1150 US bulls. In validation on cows, about 3000 Danish cows from 87 young half-sib families were used as validation data, and the reference populations were: (1) about 1250 Danish bulls, (2) about 1250 Danish bulls and about 1150 US bulls, (3) about 1250 Danish bulls and about 4800 cows, (4) about 1250 Danish bulls, 1150 US bulls and 4800 Danish cows. Genomic best linear unbiased prediction model was used to predict breeding values. De-regressed proofs were used as response variables. In the validation on bulls for eight traits, the joint DK-US bull reference population led to higher reliability of genomic prediction than the DK bull reference population for six traits, but not for fertility and longevity. Averaged over the eight traits, the gain was 3 percentage points. In the validation on cows for six traits (fertility and longevity were not available), the gain from inclusion of US bull in reference population was 6.6 percentage points in average over the six traits, and the gain from inclusion of cows was 8.2 percentage points. However, the gains from cows and US bulls were not accumulative. The total gain of including both US bulls and Danish cows was 10.5 percentage points. The results indicate that sharing reference data and including cows in reference population are efficient approaches to increase reliability of genomic prediction. Therefore, genomic selection is promising for numerically small population.

  10. 75 FR 5363 - Self-Regulatory Organizations; NYSE Arca, Inc.; Order Approving Proposed Rule Change Modifying...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-02

    ... Reference Prices constitute ``non-core data;'' i.e., the Exchange does not require a central processor to... Realtime Reference Prices Service January 22, 2010. I. Introduction On December 1, 2009, NYSE Arca, Inc... thereunder,\\2\\ a proposed rule change to add data elements to its ``NYSE Arca Realtime Reference Prices...

  11. Color-coded topography and shaded relief map of the lunar near side and far side hemispheres

    USGS Publications Warehouse

    ,

    2003-01-01

    This publication is a set of three sheets of topographic maps that presents color-coded topographic data digitally merged with shaded relief data. Adopted figure: The figure for the Moon, used for the computation of the map projection, is a sphere with a radius of 1737.4 km. Because the Moon has no surface water, and hence no sea level, the datum (the 0 km contour) for elevations is defined as the radius of 1737.4 km. Coordinates are based on the mean Earth/polar axis (M.E.) coordinates system, the z axis is the axis of the Moon's rotation, and the x axis is the mean Earth direction. The center of mass is the origin of the coordinate system. The equator lies in the x-y plane and the prime meridian lies in the x-z plane with east longitude values being positive. Projection: The projection is Lambert Azimuthal Equal Area Projection. The scale factor at the central latitude and central longitude point is 1:10,000,000. For the near side hemisphere the central latitude and central longitude point is at 0° and 0°. For the far side hemisphere the central latitude and central longitude point is at 0° and 180°.

  12. "Keep your eyes on the prize": reference points and racial differences in assessing progress toward equality.

    PubMed

    Eibach, Richard P; Ehrlinger, Joyce

    2006-01-01

    White Americans tend to perceive greater progress toward racial equality than do ethnic minorities. Correlational evidence (Study 1) and two experimental manipulations of framing (Studies 2 and 3) supported the hypothesis that this perception gap is associated with different reference points the two groups spontaneously use to assess progress, with Whites anchoring on comparisons with the past and ethnic minorities anchoring on ideal standards. Consistent with the hypothesis that the groups anchor on different reference points, the gap in perceptions of progress was affected by the time participants spent deliberating about the topic (Study 4). Implications for survey methods and political conflict are discussed.

  13. Chandra Observations of the M31

    NASA Technical Reports Server (NTRS)

    Garcia, Michael; Lavoie, Anthony R. (Technical Monitor)

    2000-01-01

    We report on Chandra observations of the nearest Spiral Galaxy, M3l, The nuclear source seen with previous X-ray observatories is resolved into five point sources. One of these sources is within 1 arc-sec of the M31 central super-massive black hole. As compared to the other point sources in M3l. this nuclear source has an unusually soft spectrum. Based on the spatial coincidence and the unusual spectrum. we identify this source with the central black hole. A bright transient is detected 26 arc-sec to the west of the nucleus, which may be associated with a stellar mass black hole. We will report on a comparison of the x-ray spectrum of the diffuse emission and point sources seen in the central few arcmin

  14. Proposed catalog of the neuroanatomy and the stratified anatomy for the 361 acupuncture points of 14 channels.

    PubMed

    Chapple, Will

    2013-10-01

    In spite of the extensive research on acupuncture mechanisms, no comprehensive and systematic peer-reviewed reference list of the stratified anatomical and the neuroanatomical features of all 361 acupuncture points exists. This study creates a reference list of the neuroanatomy and the stratified anatomy for each of the 361 acupuncture points on the 14 classical channels and for 34 extra points. Each acupuncture point was individually assessed to relate the point's location to anatomical and neuroanatomical features. The design of the catalogue is intended to be useful for any style of acupuncture or Oriental medicine treatment modality. The stratified anatomy was divided into shallow, intermediate and deep insertion. A separate stratified anatomy was presented for different needle angles and directions. The following are identified for each point: additional specifications for point location, the stratified anatomy, motor innervation, cutaneous nerve and sensory innervation, dermatomes, Langer's lines, and somatotopic organization in the primary sensory and motor cortices. Acupuncture points for each muscle, dermatome and myotome are also reported. This reference list can aid clinicians, practitioners and researchers in furthering the understanding and accurate practice of acupuncture. Additional research on the anatomical variability around acupuncture points, the frequency of needle contact with an anatomical structure in a clinical setting, and conformational imaging should be done to verify this catalogue. Copyright © 2013. Published by Elsevier B.V.

  15. Genetics Home Reference: lactose intolerance

    MedlinePlus

    ... or Free article on PubMed Central Järvelä IE. Molecular genetics of adult-type hypolactasia. Ann Med. 2005;37( ... Citation on PubMed Robayo-Torres CC, Nichols BL. Molecular differentiation of congenital lactase ... Bulletins Genetics Home Reference Celebrates Its ...

  16. Alternative Attitude Commanding and Control for Precise Spacecraft Landing

    NASA Technical Reports Server (NTRS)

    Singh, Gurkirpal

    2004-01-01

    A report proposes an alternative method of control for precision landing on a remote planet. In the traditional method, the attitude of a spacecraft is required to track a commanded translational acceleration vector, which is generated at each time step by solving a two-point boundary value problem. No requirement of continuity is imposed on the acceleration. The translational acceleration does not necessarily vary smoothly. Tracking of a non-smooth acceleration causes the vehicle attitude to exhibit undesirable transients and poor pointing stability behavior. In the alternative method, the two-point boundary value problem is not solved at each time step. A smooth reference position profile is computed. The profile is recomputed only when the control errors get sufficiently large. The nominal attitude is still required to track the smooth reference acceleration command. A steering logic is proposed that controls the position and velocity errors about the reference profile by perturbing the attitude slightly about the nominal attitude. The overall pointing behavior is therefore smooth, greatly reducing the degree of pointing instability.

  17. Performance of Mercury Triple-Point Cells Made in Brazil

    NASA Astrophysics Data System (ADS)

    Petkovic, S. G.; Santiago, J. F. N.; Filho, R. R.; Teixeira, R. N.; Santos, P. R. F.

    2003-09-01

    Fixed-points cells are primary standards in ITS-90. They contain reference material with a purity of 99.999 % or more. The gallium in a melting-point cell, for example, can reach a purity of 99.99999 %. This level of purity is not easy to obtain. However, substances like water and mercury can be purified by means of distillation and chemical procedures. This paper presents the results of mercury triple-point cells made in Brazil that were directly compared to a mercury triple-point cell of 99.999% purity. This reference cell, made by Isotech (England), was previously compared to cells from CENAM (Mexico) and NRC (Canada) and the maximum deviation found was approximately 0.4 mK. The purification stage started with a sample of mercury 99.3 % pure, and the repeated use of both mechanical and chemical processes led to a purification grade considered good enough for calibration of standard platinum resistance thermometers. The purification procedures, the method of construction of the cell, the laboratory facilities, the comparison results and the budget of uncertainties are described in this paper. All of the cells tested have a triple-point temperature within 0.25 mK of the triple-point temperature of the Inmetro reference cell.

  18. 12 CFR 204.125 - Foreign, international, and supranational entities referred to in §§ 204.2(c)(1)(iv)(E) and 204.8...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Bank. Banque Centrale des Etats de l'Afrique Equatorial et du Cameroun. Banque Centrale des Etats d'Afrique del'Ouest. Conseil de l'Entente. East African Community. Organisation Commune Africaine et Malagache. Organization of African Unity. Union des Etats de l'Afrique Centrale. Union Douaniere et...

  19. Collection development at the NOAA Central Library

    NASA Technical Reports Server (NTRS)

    Quillen, Steve R.

    1994-01-01

    The National Oceanic and Atmospheric Administration (NOAA) Central Library collection, approximately one million volumes, incorporates the holdings of its predecessor agencies. Within the library, the collections are filed separately, based on their source and/or classification schemes. The NOAA Central Library provides a variety of services to users, ranging from quick reference and interlibrary loan to in-depth research and online data bases.

  20. 76 FR 66192 - Fisheries of the Northeastern United States; Monkfish; Framework Adjustment 7

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-26

    ... with the new annual catch target, and establishes revised biomass reference points for the Northern and... biomass reference points in the Monkfish FMP to be consistent with the results of SARC 50. Approved... SARC 50 report, the Southern Demersal Working Group recommended an approach that would set biomass...

  1. Stratigraphy and characteristic mollusks of the Pamunkey Group (lower Tertiary) and the Old Church Formation of the Chesapeake Group; Virginia Coastal Plain

    USGS Publications Warehouse

    Ward, Lauck W.

    1985-01-01

    Along the Pamunkey River and its tributaries can be found a very complete, well-preserved, Tertiary stratigraphic record that reflects the sea-level changes as well as the local tectonic history of the central Virginia Coastal Plain. Using this record, I have described the lower Tertiary units and proposed a sequential model for their occurrence. Sediments examined in this study range in age from early Paleocene to latest Oligocene or earliest Miocene. Upper Tertiary units are described where they occur in the same sections with the lower Tertiary beds. The Brightseat Formation (lower Paleocene), Aquia Formation (upper Paleocene), Marlboro Clay (upper Paleocene), Nanjemoy Formation (lower Eocene), Piney Point Formation (middle Eocene) and Old Church Formation (new unit, upper Oligocene and lower Miocene) were studied. The definitions of the Piscataway and Paspotansa Members of the Aquia are amended, and a lectostratotype (principal reference section) is designated for those units as well as the Aquia on the Potomac River just below the mouth of Aquia Creek. A lectostratotype section is also designated for the Nanjemoy and its two members, the Potapaco and the Woodstock. That section is on the Potomac above Popes Creek. Beds assigned to the Piney Point and Old Church Formations, previously known only in the subsurface, crop out extensively on the Pamunkey River. A hypostratotype (reference section) is selected for the Piney Point Formation on the Pamunkey River at Horseshoe. The Old Church Formation (named herein) is included in the Chesapeake Group. Areal extent of the stratigraphic units was determined by correlation of outcropping beds on the Pamunkey, Patuxent, Potomac, Rappahannock, Mattaponi, Chickahominy, and James Rivers supplemented by well data. Comparisons of the onlap histories of the Salisbury, Albemarle, and Charleston Embayments indicate a number of simultaneous transgressive events implying global sea-level rises. More restricted transgressions appear to be the result of local downwarping.

  2. Visual navigation of the UAVs on the basis of 3D natural landmarks

    NASA Astrophysics Data System (ADS)

    Karpenko, Simon; Konovalenko, Ivan; Miller, Alexander; Miller, Boris; Nikolaev, Dmitry

    2015-12-01

    This work considers the tracking of the UAV (unmanned aviation vehicle) on the basis of onboard observations of natural landmarks including azimuth and elevation angles. It is assumed that UAV's cameras are able to capture the angular position of reference points and to measure the angles of the sight line. Such measurements involve the real position of UAV in implicit form, and therefore some of nonlinear filters such as Extended Kalman filter (EKF) or others must be used in order to implement these measurements for UAV control. Recently it was shown that modified pseudomeasurement method may be used to control UAV on the basis of the observation of reference points assigned along the UAV path in advance. However, the use of such set of points needs the cumbersome recognition procedure with the huge volume of on-board memory. The natural landmarks serving as such reference points which may be determined on-line can significantly reduce the on-board memory and the computational difficulties. The principal difference of this work is the usage of the 3D reference points coordinates which permits to determine the position of the UAV more precisely and thereby to guide along the path with higher accuracy which is extremely important for successful performance of the autonomous missions. The article suggests the new RANSAC for ISOMETRY algorithm and the use of recently developed estimation and control algorithms for tracking of given reference path under external perturbation and noised angular measurements.

  3. Linking language to the visual world: Neural correlates of comprehending verbal reference to objects through pointing and visual cues.

    PubMed

    Peeters, David; Snijders, Tineke M; Hagoort, Peter; Özyürek, Aslı

    2017-01-27

    In everyday communication speakers often refer in speech and/or gesture to objects in their immediate environment, thereby shifting their addressee's attention to an intended referent. The neurobiological infrastructure involved in the comprehension of such basic multimodal communicative acts remains unclear. In an event-related fMRI study, we presented participants with pictures of a speaker and two objects while they concurrently listened to her speech. In each picture, one of the objects was singled out, either through the speaker's index-finger pointing gesture or through a visual cue that made the object perceptually more salient in the absence of gesture. A mismatch (compared to a match) between speech and the object singled out by the speaker's pointing gesture led to enhanced activation in left IFG and bilateral pMTG, showing the importance of these areas in conceptual matching between speech and referent. Moreover, a match (compared to a mismatch) between speech and the object made salient through a visual cue led to enhanced activation in the mentalizing system, arguably reflecting an attempt to converge on a jointly attended referent in the absence of pointing. These findings shed new light on the neurobiological underpinnings of the core communicative process of comprehending a speaker's multimodal referential act and stress the power of pointing as an important natural device to link speech to objects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evaluation of six TPS algorithms in computing entrance and exit doses.

    PubMed

    Tan, Yun I; Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun; Elliott, Alex

    2014-05-08

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%-3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison.

  5. The Biomarker S100B and Mild Traumatic Brain Injury: A Meta-analysis.

    PubMed

    Oris, Charlotte; Pereira, Bruno; Durif, Julie; Simon-Pimmel, Jeanne; Castellani, Christoph; Manzano, Sergio; Sapin, Vincent; Bouvier, Damien

    2018-05-01

    The usefulness of S100B has been noted as a biomarker in the management of mild traumatic brain injury (mTBI) in adults. However, S100B efficacy as a biomarker in children has previously been relatively unclear. A meta-analysis is conducted to assess the prognostic value of S100B in predicting intracerebral lesions in children after mTBI. Medline, Embase, the Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science, Scopus, and Google Scholar. Studies including children suffering mTBI who underwent S100B measurement and computed tomography (CT) scans were included. Of 1030 articles screened, 8 studies met the inclusion criteria. The overall pooled sensitivity and specificity were 100% (95% confidence interval [CI]: 98%-100%) and 34% (95% CI: 30%-38%), respectively. A second analysis was based on the collection of 373 individual data points from 4 studies. Sensitivity and specificity results, obtained from reference ranges in children with a sampling time <3 hours posttrauma, were 97% (95% CI: 84.2%-99.9%) and 37.5% (95% CI: 28.8%-46.8%), respectively. Only 1 child had a low S100B level and a positive CT scan result without clinically important traumatic brain injury. Only patients undergoing both a CT scan and S100B testing were selected for evaluation. S100B serum analysis as a part of the clinical routine could significantly reduce the number of CT scans performed on children with mTBI. Sampling should take place within 3 hours of trauma. Cutoff levels should be based on pediatric reference ranges. Copyright © 2018 by the American Academy of Pediatrics.

  6. Fast nonlinear gravity inversion in spherical coordinates with application to the South American Moho

    NASA Astrophysics Data System (ADS)

    Uieda, Leonardo; Barbosa, Valéria C. F.

    2017-01-01

    Estimating the relief of the Moho from gravity data is a computationally intensive nonlinear inverse problem. What is more, the modelling must take the Earths curvature into account when the study area is of regional scale or greater. We present a regularized nonlinear gravity inversion method that has a low computational footprint and employs a spherical Earth approximation. To achieve this, we combine the highly efficient Bott's method with smoothness regularization and a discretization of the anomalous Moho into tesseroids (spherical prisms). The computational efficiency of our method is attained by harnessing the fact that all matrices involved are sparse. The inversion results are controlled by three hyperparameters: the regularization parameter, the anomalous Moho density-contrast, and the reference Moho depth. We estimate the regularization parameter using the method of hold-out cross-validation. Additionally, we estimate the density-contrast and the reference depth using knowledge of the Moho depth at certain points. We apply the proposed method to estimate the Moho depth for the South American continent using satellite gravity data and seismological data. The final Moho model is in accordance with previous gravity-derived models and seismological data. The misfit to the gravity and seismological data is worse in the Andes and best in oceanic areas, central Brazil and Patagonia, and along the Atlantic coast. Similarly to previous results, the model suggests a thinner crust of 30-35 km under the Andean foreland basins. Discrepancies with the seismological data are greatest in the Guyana Shield, the central Solimões and Amazonas Basins, the Paraná Basin, and the Borborema province. These differences suggest the existence of crustal or mantle density anomalies that were unaccounted for during gravity data processing.

  7. BADERI: an online database to coordinate handsearching activities of controlled clinical trials for their potential inclusion in systematic reviews.

    PubMed

    Pardo-Hernandez, Hector; Urrútia, Gerard; Barajas-Nava, Leticia A; Buitrago-Garcia, Diana; Garzón, Julieth Vanessa; Martínez-Zapata, María José; Bonfill, Xavier

    2017-06-13

    Systematic reviews provide the best evidence on the effect of health care interventions. They rely on comprehensive access to the available scientific literature. Electronic search strategies alone may not suffice, requiring the implementation of a handsearching approach. We have developed a database to provide an Internet-based platform from which handsearching activities can be coordinated, including a procedure to streamline the submission of these references into CENTRAL, the Cochrane Collaboration Central Register of Controlled Trials. We developed a database and a descriptive analysis. Through brainstorming and discussion among stakeholders involved in handsearching projects, we designed a database that met identified needs that had to be addressed in order to ensure the viability of handsearching activities. Three handsearching teams pilot tested the proposed database. Once the final version of the database was approved, we proceeded to train the staff involved in handsearching. The proposed database is called BADERI (Database of Iberoamerican Clinical Trials and Journals, by its initials in Spanish). BADERI was officially launched in October 2015, and it can be accessed at www.baderi.com/login.php free of cost. BADERI has an administration subsection, from which the roles of users are managed; a references subsection, where information associated to identified controlled clinical trials (CCTs) can be entered; a reports subsection, from which reports can be generated to track and analyse the results of handsearching activities; and a built-in free text search engine. BADERI allows all references to be exported in ProCite files that can be directly uploaded into CENTRAL. To date, 6284 references to CCTs have been uploaded to BADERI and sent to CENTRAL. The identified CCTs were published in a total of 420 journals related to 46 medical specialties. The year of publication ranged between 1957 and 2016. BADERI allows the efficient management of handsearching activities across different countries and institutions. References to all CCTs available in BADERI can be readily submitted to CENTRAL for their potential inclusion in systematic reviews.

  8. A Smart Power Electronic Multiconverter for the Residential Sector.

    PubMed

    Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva

    2017-05-26

    The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it.

  9. Solar tower cavity receiver aperture optimization based on transient optical and thermo-hydraulic modeling

    NASA Astrophysics Data System (ADS)

    Schöttl, Peter; Bern, Gregor; van Rooyen, De Wet; Heimsath, Anna; Fluri, Thomas; Nitz, Peter

    2017-06-01

    A transient simulation methodology for cavity receivers for Solar Tower Central Receiver Systems with molten salt as heat transfer fluid is described. Absorbed solar radiation is modeled with ray tracing and a sky discretization approach to reduce computational effort. Solar radiation re-distribution in the cavity as well as thermal radiation exchange are modeled based on view factors, which are also calculated with ray tracing. An analytical approach is used to represent convective heat transfer in the cavity. Heat transfer fluid flow is simulated with a discrete tube model, where the boundary conditions at the outer tube surface mainly depend on inputs from the previously mentioned modeling aspects. A specific focus is put on the integration of optical and thermo-hydraulic models. Furthermore, aiming point and control strategies are described, which are used during the transient performance assessment. Eventually, the developed simulation methodology is used for the optimization of the aperture opening size of a PS10-like reference scenario with cavity receiver and heliostat field. The objective function is based on the cumulative gain of one representative day. Results include optimized aperture opening size, transient receiver characteristics and benefits of the implemented aiming point strategy compared to a single aiming point approach. Future work will include annual simulations, cost assessment and optimization of a larger range of receiver parameters.

  10. A Smart Power Electronic Multiconverter for the Residential Sector

    PubMed Central

    Guerrero-Martinez, Miguel Angel; Milanes-Montero, Maria Isabel; Barrero-Gonzalez, Fermin; Miñambres-Marcos, Victor Manuel; Romero-Cadaval, Enrique; Gonzalez-Romera, Eva

    2017-01-01

    The future of the grid includes distributed generation and smart grid technologies. Demand Side Management (DSM) systems will also be essential to achieve a high level of reliability and robustness in power systems. To do that, expanding the Advanced Metering Infrastructure (AMI) and Energy Management Systems (EMS) are necessary. The trend direction is towards the creation of energy resource hubs, such as the smart community concept. This paper presents a smart multiconverter system for residential/housing sector with a Hybrid Energy Storage System (HESS) consisting of supercapacitor and battery, and with local photovoltaic (PV) energy source integration. The device works as a distributed energy unit located in each house of the community, receiving active power set-points provided by a smart community EMS. This central EMS is responsible for managing the active energy flows between the electricity grid, renewable energy sources, storage equipment and loads existing in the community. The proposed multiconverter is responsible for complying with the reference active power set-points with proper power quality; guaranteeing that the local PV modules operate with a Maximum Power Point Tracking (MPPT) algorithm; and extending the lifetime of the battery thanks to a cooperative operation of the HESS. A simulation model has been developed in order to show the detailed operation of the system. Finally, a prototype of the multiconverter platform has been implemented and some experimental tests have been carried out to validate it. PMID:28587131

  11. Update on the efficacy of extracorporeal shockwave treatment for myofascial pain syndrome and fibromyalgia.

    PubMed

    Ramon, Silvia; Gleitz, Markus; Hernandez, Leonor; Romero, Luis David

    2015-12-01

    Chronic muscle pain syndrome is one of the main causes of musculoskeletal pathologies requiring treatment. Many terms have been used in the past to describe painful muscular syndromes in the absence of evident local nociception such as myogelosis, muscle hardening, myalgia, muscular rheumatism, fibrositis or myofascial trigger point with or without referred pain. If it persists over six months or more, it often becomes therapy resistant and frequently results in chronic generalized pain, characterized by a high degree of subjective suffering. Myofascial pain syndrome (MPS) is defined as a series of sensory, motor, and autonomic symptoms caused by a stiffness of the muscle, caused by hyperirritable nodules in musculoskeletal fibers, known as myofascial trigger points (MTP), and fascial constrictions. Fibromyalgia (FM) is a chronic condition that involves both central and peripheral sensitization and for which no curative treatment is available at the present time. Fibromyalgia shares some of the features of MPS, such as hyperirritability. Many treatments options have been described for muscle pain syndrome, with differing evidence of efficacy. Extracorporeal Shockwave Treatment (ESWT) offers a new and promising treatment for muscular disorders. We will review the existing bibliography on the evidence of the efficacy of ESWT for MPS, paying particular attention to MTP (Myofascial Trigger Point) and Fibromyalgia (FM). Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  12. Precision Pointing Control System (PPCS) system design and analysis. [for gimbaled experiment platforms

    NASA Technical Reports Server (NTRS)

    Frew, A. M.; Eisenhut, D. F.; Farrenkopf, R. L.; Gates, R. F.; Iwens, R. P.; Kirby, D. K.; Mann, R. J.; Spencer, D. J.; Tsou, H. S.; Zaremba, J. G.

    1972-01-01

    The precision pointing control system (PPCS) is an integrated system for precision attitude determination and orientation of gimbaled experiment platforms. The PPCS concept configures the system to perform orientation of up to six independent gimbaled experiment platforms to design goal accuracy of 0.001 degrees, and to operate in conjunction with a three-axis stabilized earth-oriented spacecraft in orbits ranging from low altitude (200-2500 n.m., sun synchronous) to 24 hour geosynchronous, with a design goal life of 3 to 5 years. The system comprises two complementary functions: (1) attitude determination where the attitude of a defined set of body-fixed reference axes is determined relative to a known set of reference axes fixed in inertial space; and (2) pointing control where gimbal orientation is controlled, open-loop (without use of payload error/feedback) with respect to a defined set of body-fixed reference axes to produce pointing to a desired target.

  13. Nonimaging optical illumination system

    DOEpatents

    Winston, Roland; Ries, Harald

    2000-01-01

    A nonimaging illumination optical device for producing a selected far field illuminance over an angular range. The optical device includes a light source 102, a light reflecting surface 108, and a family of light edge rays defined along a reference line 104 with the reflecting surface 108 defined in terms of the reference line 104 as a parametric function R(t) where t is a scalar parameter position and R(t)=k(t)+Du(t) where k(t) is a parameterization of the reference line 104, and D is a distance from a point on the reference line 104 to the reflection surface 108 along the desired edge ray through the point.

  14. Nonimaging optical illumination system

    DOEpatents

    Winston, Roland; Ries, Harald

    1998-01-01

    A nonimaging illumination optical device for producing a selected far field illuminance over an angular range. The optical device includes a light source 102, a light reflecting surface 108, and a family of light edge rays defined along a reference line 104 with the reflecting surface 108 defined in terms of the reference line 104 as a parametric function R(t) where t is a scalar parameter position and R(t)=k(t)+Du(t) where k(t) is a parameterization of the reference line 104, and D is a distance from a point on the reference line 104 to the reflection surface 108 along the desired edge ray through the point.

  15. Nonimaging optical illumination system

    DOEpatents

    Winston, Roland; Ries, Harald

    1996-01-01

    A nonimaging illumination optical device for producing a selected far field illuminance over an angular range. The optical device includes a light source 102, a light reflecting surface 108, and a family of light edge rays defined along a reference line 104 with the reflecting surface 108 defined in terms of the reference line 104 as a parametric function R(t) where t is a scalar parameter position and R(t)=k(t)+Du(t) where k(t) is a parameterization of the reference line 104, and D is a distance from a point on the reference line 104 to the reflection surface 108 along the desired edge ray through the point.

  16. Implementing system simulation of C3 systems using autonomous objects

    NASA Technical Reports Server (NTRS)

    Rogers, Ralph V.

    1987-01-01

    The basis of all conflict recognition in simulation is a common frame of reference. Synchronous discrete-event simulation relies on the fixed points in time as the basic frame of reference. Asynchronous discrete-event simulation relies on fixed-points in the model space as the basic frame of reference. Neither approach provides sufficient support for autonomous objects. The use of a spatial template as a frame of reference is proposed to address these insufficiencies. The concept of a spatial template is defined and an implementation approach offered. Discussed are the uses of this approach to analyze the integration of sensor data associated with Command, Control, and Communication systems.

  17. Parametric representation of open quantum systems and cross-over from quantum to classical environment.

    PubMed

    Calvani, Dario; Cuccoli, Alessandro; Gidopoulos, Nikitas I; Verrucchi, Paola

    2013-04-23

    The behavior of most physical systems is affected by their natural surroundings. A quantum system with an environment is referred to as open, and its study varies according to the classical or quantum description adopted for the environment. We propose an approach to open quantum systems that allows us to follow the cross-over from quantum to classical environments; to achieve this, we devise an exact parametric representation of the principal system, based on generalized coherent states for the environment. The method is applied to the s = 1/2 Heisenberg star with frustration, where the quantum character of the environment varies with the couplings entering the Hamiltonian H. We find that when the star is in an eigenstate of H, the central spin behaves as if it were in an effective magnetic field, pointing in the direction set by the environmental coherent-state angle variables (θ, ϕ), and broadened according to their quantum probability distribution. Such distribution is independent of ϕ, whereas as a function of θ is seen to get narrower as the quantum character of the environment is reduced, collapsing into a Dirac-δ function in the classical limit. In such limit, because ϕ is left undetermined, the Von Neumann entropy of the central spin remains finite; in fact, it is equal to the entanglement of the original fully quantum model, a result that establishes a relation between this latter quantity and the Berry phase characterizing the dynamics of the central spin in the effective magnetic field.

  18. Reading Gate Positions with a Smartphone

    NASA Astrophysics Data System (ADS)

    van Overloop, Peter-Jules; Hut, Rolf

    2015-04-01

    Worldwide many flow gates are built in water networks in order to direct water to appropriate locations. Most of these gates are adjusted manually by field operators of water management organizations and it is often centrally not known what the new position of the gate is. This makes centralized management of the entire water network difficult. One of the reasons why the measurement of the gate position is usually not executed, is that for certain gates it is not easy to do such a reading. Tilting weirs or radial gates are examples where operators need special equipment (measuring rod and long level) to determine the position and it could even be a risky procedure. Another issue is that once the measurement is done, the value is jotted down in a notebook and later, at the office, entered in a computer system. So the entire monitoring procedure is not real-time and prone to human errors. A new way of monitoring gate positions is introduced. It consists of a level that is attached to the gate and an app with which a picture can be taken from the level. Using dedicated pattern recognition algorithms, the gate position can be read by using the angle of the level versus reference points on the gate, the radius of that gate and the absolute level of the joint around which the gate turn. The method uses gps-localization of the smartphone to store the gate position in the right location in the central database.

  19. KEY COMPARISON: Final Report on CCT-K7: Key comparison of water triple point cells

    NASA Astrophysics Data System (ADS)

    Stock, M.; Solve, S.; del Campo, D.; Chimenti, V.; Méndez-Lango, E.; Liedberg, H.; Steur, P. P. M.; Marcarino, P.; Dematteis, R.; Filipe, E.; Lobo, I.; Kang, K. H.; Gam, K. S.; Kim, Y.-G.; Renaot, E.; Bonnier, G.; Valin, M.; White, R.; Dransfield, T. D.; Duan, Y.; Xiaoke, Y.; Strouse, G.; Ballico, M.; Sukkar, D.; Arai, M.; Mans, A.; de Groot, M.; Kerkhof, O.; Rusby, R.; Gray, J.; Head, D.; Hill, K.; Tegeler, E.; Noatsch, U.; Duris, S.; Kho, H. Y.; Ugur, S.; Pokhodun, A.; Gerasimov, S. F.

    2006-01-01

    The triple point of water serves to define the kelvin, the unit of thermodynamic temperature, in the International System of Units (SI). Furthermore, it is the most important fixed point of the International Temperature Scale of 1990 (ITS-90). Any uncertainty in the realization of the triple point of water contributes directly to the measurement uncertainty over the wide temperature range from 13.8033 K to 1234.93 K. The Consultative Committee for Thermometry (CCT) decided at its 21st meeting in 2001 to carry out a comparison of water triple point cells and charged the BIPM with its organization. Water triple point cells from 20 national metrology institutes were carried to the BIPM and were compared with highest accuracy with two reference cells. The small day-to-day changes of the reference cells were determined by a least-squares technique. Prior to the measurements at the BIPM, the transfer cells were compared with the corresponding national references and therefore also allow comparison of the national references of the water triple point. This report presents the results of this comparison and gives detailed information about the measurements made at the BIPM and in the participating laboratories. It was found that the transfer cells show a standard deviation of 50 µK the difference between the extremes is 160 µK. The same spread is observed between the national references. The most important result of this work is that a correlation between the isotopic composition of the cell water and the triple point temperature was observed. To reduce the spread between different realizations, it is therefore proposed that the definition of the kelvin should refer to water of a specified isotopic composition. The CCT recommended to the International Committee of Weights and Measures (CIPM) to clarify the definition of the kelvin in the SI brochure by explicitly referring to water with the isotopic composition of Vienna Standard Mean Ocean Water (VSMOW). The CIPM accepted this recommendation and the next edition of the SI brochure will include this specification. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  20. Practical challenges related to point of care testing.

    PubMed

    Shaw, Julie L V

    2016-04-01

    Point of care testing (POCT) refers to laboratory testing that occurs near to the patient, often at the patient bedside. POCT can be advantageous in situations requiring rapid turnaround time of test results for clinical decision making. There are many challenges associated with POCT, mainly related to quality assurance. POCT is performed by clinical staff rather than laboratory trained individuals which can lead to errors resulting from a lack of understanding of the importance of quality control and quality assurance practices. POCT is usually more expensive than testing performed in the central laboratory and requires a significant amount of support from the laboratory to ensure the quality testing and meet accreditation requirements. Here, specific challenges related to POCT compliance with accreditation standards are discussed along with strategies that can be used to overcome these challenges. These areas include: documentation of POCT orders, charting of POCT results as well as training and certification of individuals performing POCT. Factors to consider when implementing connectivity between POCT instruments and the electronic medical record are also discussed in detail and include: uni-directional versus bidirectional communication, linking patient demographic information with POCT software, the importance of positive patient identification and considering where to chart POCT results in the electronic medical record.

  1. Volume 2 - Point Sources

    EPA Pesticide Factsheets

    Point source emission reference materials from the Emissions Inventory Improvement Program (EIIP). Provides point source guidance on planning, emissions estimation, data collection, inventory documentation and reporting, and quality assurance/quality contr

  2. SDSS-IV MaNGA - the spatially resolved transition from star formation to quiescence

    NASA Astrophysics Data System (ADS)

    Belfiore, Francesco; Maiolino, Roberto; Maraston, Claudia; Emsellem, Eric; Bershady, Matthew A.; Masters, Karen L.; Bizyaev, Dmitry; Boquien, Médéric; Brownstein, Joel R.; Bundy, Kevin; Diamond-Stanic, Aleksandar M.; Drory, Niv; Heckman, Timothy M.; Law, David R.; Malanushenko, Olena; Oravetz, Audrey; Pan, Kaike; Roman-Lopes, Alexandre; Thomas, Daniel; Weijmans, Anne-Marie; Westfall, Kyle B.; Yan, Renbin

    2017-04-01

    Using spatially resolved spectroscopy from SDSS-IV MaNGA we have demonstrated that low ionization emission-line regions (LIERs) in local galaxies result from photoionization by hot evolved stars, not active galactic nuclei, hence tracing galactic region hosting old stellar population where, despite the presence of ionized gas, star formation is no longer occurring. LIERs are ubiquitous in both quiescent galaxies and in the central regions of galaxies where star formation takes place at larger radii. We refer to these two classes of galaxies as extended LIER (eLIER) and central LIER (cLIER) galaxies, respectively. cLIERs are late-type galaxies primarily spread across the green valley, in the transition region between the star formation main sequence and quiescent galaxies. These galaxies display regular disc rotation in both stars and gas, although featuring a higher central stellar velocity dispersion than star-forming galaxies of the same mass. cLIERs are consistent with being slowly quenched inside-out; the transformation is associated with massive bulges, pointing towards the importance of bulge growth via secular evolution. eLIERs are morphologically early types and are indistinguishable from passive galaxies devoid of line emission in terms of their stellar populations, morphology and central stellar velocity dispersion. Ionized gas in eLIERs shows both disturbed and disc-like kinematics. When a large-scale flow/rotation is observed in the gas, it is often misaligned relative to the stellar component. These features indicate that eLIERs are passive galaxies harbouring a residual cold gas component, acquired mostly via external accretion. Importantly, quiescent galaxies devoid of line emission reside in denser environments and have significantly higher satellite fraction than eLIERs. Environmental effects thus represent the likely cause for the existence of line-less galaxies on the red sequence.

  3. Survey of abdominal obesities in an adult urban population of Kinshasa, Democratic Republic of Congo

    PubMed Central

    Kasiam Lasi On’kin, JB; Longo-Mbenza, B; Okwe, A Nge; Kabangu, N Kangola

    2007-01-01

    Summary Background The prevalence of overweight/obesity, which is an important cardiovascular risk factor, is rapidly increasing worldwide. Abdominal obesity, a fundamental component of the metabolic syndrome, is not defined by appropriate cutoff points for sub-Saharan Africa. Objective To provide baseline and reference data on the anthropometry/body composition and the prevalence rates of obesity types and levels in the adult urban population of Kinshasa, DRC, Central Africa. Methods During this cross-sectional study carried out within a random sample of adults in Kinshasa town, body mass index, waist circumference and fatty mass were measured using standard methods. Their reference and local thresholds (cut-off points) were compared with those of WHO, NCEP and IFD to define the types and levels of obesity in the population. Results From this sample of 11 511 subjects (5 676 men and 5 835 women), the men presented with similar body mass index and fatty mass values to those of the women, but higher waist measurements. The international thresholds overestimated the prevalence of denutrition, but underscored that of general and abdominal obesity. The two types of obesity were more prevalent among women than men when using both international and local thresholds. Body mass index was negatively associated with age; but abdominal obesity was more frequent before 20 years of age and between 40 and 60 years old. Local thresholds of body mass index (≥ 23, ≥ 27 and ≥ 30 kg/m2) and waist measurement (≥ 80, ≥ 90 and ≥ 94 cm) defined epidemic rates of overweight/general obesity (52%) and abdominal obesity (40.9%). The threshold of waist circumference ≥ 94 cm (90th percentile) corresponding to the threshold of the body mass index ≥ 30 kg/m2 (90th percentile) was proposed as the specific threshold of definition of the metabolic syndrome, without reference to gender, for the cities of sub-Saharan Africa. Conclusion Further studies are required to define the optimal threshold of waist circumference in rural settings. The present local cut-off points of body mass index and waist circumference could be appropriate for the identification of Africans at risk of obesity-related disorders, and indicate the need to implement interventions to reverse increasing levels of obesity. PMID:17985031

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlichenmaier, M

    Recently, Lax operator algebras appeared as a new class of higher genus current-type algebras. Introduced by Krichever and Sheinman, they were based on Krichever's theory of Lax operators on algebraic curves. These algebras are almost-graded Lie algebras of currents on Riemann surfaces with marked points (in-points, out-points and Tyurin points). In a previous joint article with Sheinman, the author classified the local cocycles and associated almost-graded central extensions in the case of one in-point and one out-point. It was shown that the almost-graded extension is essentially unique. In this article the general case of Lax operator algebras corresponding to several in- andmore » out-points is considered. As a first step they are shown to be almost-graded. The grading is given by splitting the marked points which are non-Tyurin points into in- and out-points. Next, classification results both for local and bounded cocycles are proved. The uniqueness theorem for almost-graded central extensions follows. To obtain this generalization additional techniques are needed which are presented in this article. Bibliography: 30 titles.« less

  5. Connecting Online Learners with Diverse Local Practices: The Design of Effective Common Reference Points for Conversation

    ERIC Educational Resources Information Center

    Friend Wise, Alyssa; Padmanabhan, Poornima; Duffy, Thomas M.

    2009-01-01

    This mixed-methods study probed the effectiveness of three kinds of objects (video, theory, metaphor) as common reference points for conversations between online learners (student teachers). Individuals' degree of detail-focus was examined as a potentially interacting covariate and the outcome measure was learners' level of tacit knowledge related…

  6. NGEE Arctic Plant Traits: Vegetation Plot Locations, Ecotypes, and Photos, Kougarok Road Mile Marker 64, Seward Peninsula, Alaska, 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colleen Iversen; Amy Breen; Verity Salmon

    Data includes GPS waypoints for intensive plots, reference points, vegetation plots, and soil temperature/moisture monitoring stations that were established in July 2016 at the Kougarok hill slope located at Kougarok Road, Mile Marker 64. Photographs of all intensive plots and reference points are also included.

  7. Tipping Points: Teachers' Reported Reasons for Referring Primary School Children for Excessive Anxiety

    ERIC Educational Resources Information Center

    Hinchliffe, Kaitlin J.; Campbell, Marilyn A.

    2016-01-01

    The current study explored the reasons that primary school teachers reported were tipping points for them in deciding whether or not and when to refer a child to the school student support team for excessive anxiety. Twenty teachers in two Queensland primary schools were interviewed. Content analysis of interview transcripts revealed six themes…

  8. JPRS Report, East Europe. Reference Aid: Abbreviations in the Polish Press.

    DTIC Science & Technology

    1989-12-07

    Artykulami Rolnymi Centralne Biuro Obrotu Maszynami Centrum Badania Opinii Spolecznej Centralne Biuro Planowania Centralne Biuro Projektöw... Badania Odmian Roslin Uprawnych Central Optical Laboratory Central Laboratory of the Wood Products Industry Central Laboratory of the...Glöwny Inspektorat Wyszkolenia Bojowego Glöwny Komitet Gminny Komitet Glöwna Komisja Arbitrazowa Glöwna Komisja Badania Zbrodni Hitlerowskich w

  9. Does Central Coherence Relate to the Cognitive Performance of Children with Autism in Dynamic Assessments?

    ERIC Educational Resources Information Center

    Aljunied, Mariam; Frederickson, Norah

    2013-01-01

    Central coherence refers to an in-built propensity to form meaningful links over a wide range of stimuli and to generalize over as wide a range of contexts as possible. In children with autism this ability is diminished, and the impact of central coherence deficits in children with autism have previously been observed using static measures of…

  10. Scattered radiation doses absorbed by technicians at different distances from X-ray exposure: Experiments on prosthesis.

    PubMed

    Chiang, Hsien-Wen; Liu, Ya-Ling; Chen, Tou-Rong; Chen, Chun-Lon; Chiang, Hsien-Jen; Chao, Shin-Yu

    2015-01-01

    This work aimed to investigate the spatial distribution of scattered radiation doses induced by exposure to the portable X-ray, the C-arm machine, and to simulate the radiologist without a shield of lead clothing, radiation doses absorbed by medical staff at 2 m from the central exposure point. With the adoption of the Rando Phantom, several frequently X-rayed body parts were exposed to X-ray radiation, and the scattered radiation doses were measured by ionization chamber dosimeters at various angles from the patient. Assuming that the central point of the X-ray was located at the belly button, five detection points were distributed in the operation room at 1 m above the ground and 1-2 m from the central point horizontally. The radiation dose measured at point B was the lowest, and the scattered radiation dose absorbed by the prosthesis from the X-ray's vertical projection was 0.07 ±0.03 μGy, which was less than the background radiation levels. The Fluke biomedical model 660-5DE (400 cc) and 660-3DE (4 cc) ion chambers were used to detect air dose at a distance of approximately two meters from the central point. The AP projection radiation doses at point B was the lowest (0.07±0.03 μGy) and the radiation doses at point D was the highest (0.26±0.08 μGy) .Only taking the vertical projection into account, the radiation doses at point B was the lowest (0.52 μGy), and the radiation doses at point E was the highest (4 μGy).The PA projection radiation at point B was the lowest (0.36 μGy) and the radiation doses at point E was the highest(2.77 μGy), occupying 10-32% of the maximum doses. The maximum dose in five directions was nine times to the minimum dose. When the PX and the C-arm machine were used, the radiation doses at a distance of 2 m were attenuated to the background radiation level. The radiologist without a lead shield should stand at point B of patient's feet. Accordingly, teaching materials on radiation safety for radiological interns and clinical technicians were formulated.

  11. Chandra Detects Enigmatic Point X-ray Sources in the Cat's Eye and the Helix Nebulae

    NASA Astrophysics Data System (ADS)

    Guerrero, M. A.; Gruendl, R. A.; Chu, Y.-H.; Kaler, J. B.; Williams, R. M.

    2000-12-01

    Central stars of planetary nebulae (PNe) with Teff greater than 100,000 K are expected to emit soft X-rays that peak below 0.1 keV. Chandra ACIS-S observations of the Cat's Eye Nebula (NGC 6543) and the Helix Nebula (NGC 7293) have detected point X-ray sources at their central stars. The point X-ray source at the central star of the Cat's Eye is both unknown previously and unexpected because the stellar temperature is only ~50,000 K. In contrast, the point X-ray source at the central star of the Helix was previously detected by ROSAT and its soft X-ray emission is expected because the stellar temperature is ~100,000 K. However, the Helix X-ray source also shows a harder X-ray component peaking at 0.8 keV that is unexpected and for which Chandra has provided the first high-resolution spectrum for detailed analysis. The spectra of the point X-ray sources in the Cat's Eye and the Helix show line features indicating an origin of thermal plasma emission. The spectrum of the Helix source can be fit by Raymond & Smith's model of plasma emission at ~9*E6 K. The spectrum of the Cat's Eye source has too few counts for a spectral fit, but appears to be consistent with plasma emission at 2-3*E6 K. The X-ray luminosities of both sources are ~5*E29 erg s-1. The observed plasma temperatures are too high for accretion disks around white dwarfs, but they could be ascribed to coronal X-ray emission. While central stars of PNe are not known to have coronae, the observed spectra are consistent with quiescent X-ray emission from dM flare stars. On the other hand, neither the central star of the Helix or the Cat's Eye are known to have a binary companion. It is possible that the X-rays from the Cat's Eye's central star originate from shocks in the stellar wind, but the central star of the Helix does not have a measurable fast stellar wind. This work is supported by the CXC grant number GO0-1004X.

  12. Improvements of the Ray-Tracing Based Method Calculating Hypocentral Loci for Earthquake Location

    NASA Astrophysics Data System (ADS)

    Zhao, A. H.

    2014-12-01

    Hypocentral loci are very useful to reliable and visual earthquake location. However, they can hardly be analytically expressed when the velocity model is complex. One of methods numerically calculating them is based on a minimum traveltime tree algorithm for tracing rays: a focal locus is represented in terms of ray paths in its residual field from the minimum point (namely initial point) to low residual points (referred as reference points of the focal locus). The method has no restrictions on the complexity of the velocity model but still lacks the ability of correctly dealing with multi-segment loci. Additionally, it is rather laborious to set calculation parameters for obtaining loci with satisfying completeness and fineness. In this study, we improve the ray-tracing based numerical method to overcome its advantages. (1) Reference points of a hypocentral locus are selected from nodes of the model cells that it goes through, by means of a so-called peeling method. (2) The calculation domain of a hypocentral locus is defined as such a low residual area that its connected regions each include one segment of the locus and hence all the focal locus segments are respectively calculated with the minimum traveltime tree algorithm for tracing rays by repeatedly assigning the minimum residual reference point among those that have not been traced as an initial point. (3) Short ray paths without branching are removed to make the calculated locus finer. Numerical tests show that the improved method becomes capable of efficiently calculating complete and fine hypocentral loci of earthquakes in a complex model.

  13. The Geodetic Monitoring of the Engineering Structure - A Practical Solution of the Problem in 3D Space

    NASA Astrophysics Data System (ADS)

    Filipiak-Kowszyk, Daria; Janowski, Artur; Kamiński, Waldemar; Makowska, Karolina; Szulwic, Jakub; Wilde, Krzysztof

    2016-12-01

    The study raises the issues concerning the automatic system designed for the monitoring of movement of controlled points, located on the roof covering of the Forest Opera in Sopot. It presents the calculation algorithm proposed by authors. It takes into account the specific design and location of the test object. High forest stand makes it difficult to use distant reference points. Hence the reference points used to study the stability of the measuring position are located on the ground elements of the sixmeter-deep concrete foundations, from which the steel arches are derived to support the roof covering (membrane) of the Forest Opera. The tacheometer used in the measurements is located in the glass body placed on a special platform attached to the steel arcs. Measurements of horizontal directions, vertical angles and distances can be additionally subject to errors caused by the laser beam penetration through the glass. Dynamic changes of weather conditions, including the temperature and pressure also have a significant impact on the value of measurement errors, and thus the accuracy of the final determinations represented by the relevant covariance matrices. The estimated coordinates of the reference points, controlled points and tacheometer along with the corresponding covariance matrices obtained from the calculations in the various epochs are used to determine the significance of acquired movements. In case of the stability of reference points, the algorithm assumes the ability to study changes in the position of tacheometer in time, on the basis of measurements performed on these points.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, R; Zhu, X; Li, S

    Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginalmore » mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.« less

  15. Geoscience laser altimeter system-stellar reference system

    NASA Astrophysics Data System (ADS)

    Millar, Pamela S.; Sirota, J. Marcos

    1998-01-01

    GLAS is an EOS space-based laser altimeter being developed to profile the height of the Earth's ice sheets with ~15 cm single shot accuracy from space under NASA's Mission to Planet Earth (MTPE). The primary science goal of GLAS is to determine if the ice sheets are increasing or diminishing for climate change modeling. This is achieved by measuring the ice sheet heights over Greenland and Antarctica to 1.5 cm/yr over 100 km×100 km areas by crossover analysis (Zwally 1994). This measurement performance requires the instrument to determine the pointing of the laser beam to ~5 urad (1 arcsecond), 1-sigma, with respect to the inertial reference frame. The GLAS design incorporates a stellar reference system (SRS) to relate the laser beam pointing angle to the star field with this accuracy. This is the first time a spaceborne laser altimeter is measuring pointing to such high accuracy. The design for the stellar reference system combines an attitude determination system (ADS) with a laser reference system (LRS) to meet this requirement. The SRS approach and expected performance are described in this paper.

  16. Transit traverse in Missouri, 1900-1937. Part 7, Central Missouri, 1902-37

    USGS Publications Warehouse

    Staack, John George

    1940-01-01

    This bulletin, which for convenience is to be published in eight parts, contains the results of all transit traverse* done In Missouri through 1937 by the Geological Survey, United States Department of the Interior, including those heretofore published. (See page X.) Each of the parts deals with one of eight sections into which the State has been divided for this purpose and which have been designated northeastern, northwestern, southeastern, southwestern, central, east-central, south-central, and west-central Missouri. In each part descriptions of the points for which geodetic positions have been determined are listed according to the quadrangles in which the points occur. Results of transit traverse other than that done by the Geological Survey have not been included.Central Missouri, as the term is used in this bulletin and as the subject of part 7 of the bulletin, is that section of the State lying between latitudes 36°00' and 39°30' and between longitudes 92°00' and 93°30'.

  17. Transit traverse in Missouri, 1900-1937. Part 8, West-central Missouri, 1906-37

    USGS Publications Warehouse

    Staack, John G.

    1940-01-01

    This bulletin, which for convenience is to be published in eight parts, contains the results of all transit traverse* done In Missouri through 1937 by the Geological Survey, United States Department of the Interior, including those heretofore published. (See page X.) Each of the parts deals with one of eight sections into which the State has been divided for this purpose and which have been designated northeastern, northwestern, southeastern, southwestern, central, east-central, south-central, and west-central Missouri. In each part descriptions of the points for which geodetic positions have been determined are listed according to the quadrangles in which the points occur. Results of transit traverse other than that done by the Geological Survey have not been included.West-central Missouri, as the term is used in this bulletin and as the subject of part 8 of the bulletin, is that section of the State lying between latitudes 38°00' and 39°30' and west of longitude 93°30'.

  18. Data on the fungal species consumed by mammal species in Australia.

    PubMed

    Nuske, S J; Vernes, K; May, T W; Claridge, A W; Congdon, B C; Krockenberger, A; Abell, S E

    2017-06-01

    The data reported here support the manuscript Nuske et al. (2017) [1]. Searches were made for quantitative data on the occurrence of fungi within dietary studies of Australian mammal species. The original location reported in each study was used as the lowest grouping variable within the dataset. To standardise the data and compare dispersal events from populations of different mammal species that might overlap, data from locations were further pooled and averaged across sites if they occurred within 100 km of a random central point. Three locations in Australia contained data on several (>7) mycophagous mammals, all other locations had data on 1-3 mammal species. Within these three locations, the identity of the fungi species was compared between mammal species' diets. A list of all fungi species found in Australian mammalian diets is also provide along with the original reference and fungal synonym names.

  19. Ceramide induced mitophagy and tumor suppression

    PubMed Central

    Dany, Mohammed; Ogretmen, Besim

    2015-01-01

    Sphingolipids are bioactive lipid effectors, which are involved in the regulation of various cellular signaling pathways. Sphingolipids play essential roles in controlling cell inflammation, proliferation, death, migration, senescence, metastasis and autophagy. Alterations in sphingolipid metabolism has been also implicated in many human cancers. Macroautophagy (referred to here as autophagy) is a form of nonselective sequestering of cytosolic materials by double membrane structures, autophagosomes, which can be either protective or lethal for cells. Ceramide, a central molecule of sphingolipid metabolism is involved in the regulation of autophagy at various levels, including the induction of lethal mitophagy, a selective autophagy process to target and eliminate damaged mitochondria. In this review, we focused on recent studies with regard to the regulation of autophagy, in particular lethal mitophagy, by ceramide, and aimed at providing discussion points for various context-dependent roles and mechanisms of action of ceramide in controlling mitophagy. PMID:25634657

  20. Resident training in point-of-care testing.

    PubMed

    Campbell, Sheldon; Howanitz, Peter J

    2007-06-01

    Although central laboratory testing has been the norm for the last few decades and point-of-care testing (POCT) is considered an emerging area, physicians were performing POCT long before the existence of central laboratory testing. As medical directors of POCT programs, pathologists need the basic knowledge and skills associated with directing laboratory-based testing programs as well as additional knowledge and skills about testing at the point of care. Although the essential elements of quality testing are the same for laboratory-based and POCT, the enormous variety of settings, technologies, and workers involved present unique challenges.

  1. Structural re-alignment in an immunologic surface region of ricin A chain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zemla, A T; Zhou, C E

    2007-07-24

    We compared structure alignments generated by several protein structure comparison programs to determine whether existing methods would satisfactorily align residues at a highly conserved position within an immunogenic loop in ribosome inactivating proteins (RIPs). Using default settings, structure alignments generated by several programs (CE, DaliLite, FATCAT, LGA, MAMMOTH, MATRAS, SHEBA, SSM) failed to align the respective conserved residues, although LGA reported correct residue-residue (R-R) correspondences when the beta-carbon (Cb) position was used as the point of reference in the alignment calculations. Further tests using variable points of reference indicated that points distal from the beta carbon along a vector connectingmore » the alpha and beta carbons yielded rigid structural alignments in which residues known to be highly conserved in RIPs were reported as corresponding residues in structural comparisons between ricin A chain, abrin-A, and other RIPs. Results suggest that approaches to structure alignment employing alternate point representations corresponding to side chain position may yield structure alignments that are more consistent with observed conservation of functional surface residues than do standard alignment programs, which apply uniform criteria for alignment (i.e., alpha carbon (Ca) as point of reference) along the entirety of the peptide chain. We present the results of tests that suggest the utility of allowing user-specified points of reference in generating alternate structural alignments, and we present a web server for automatically generating such alignments.« less

  2. Nucleic-acid testing, new platforms and nanotechnology for point-of-decision diagnosis of animal pathogens.

    PubMed

    Teles, Fernando; Fonseca, Luís

    2015-01-01

    Accurate disease diagnosis in animals is crucial for animal well-being but also for preventing zoonosis transmission to humans. In particular, livestock diseases may constitute severe threats to humans due to the particularly high physical contact and exposure and, also, be the cause of important economic losses, even in non-endemic countries, where they often arise in the form of rapid and devastating epidemics. Rapid diagnostic tests have been used for a long time in field situations, particularly during outbreaks. However, they mostly rely on serological approaches, which may confirm the exposure to a particular pathogen but may be inappropriate for point-of-decision (point-of-care) settings when emergency responses supported on early and accurate diagnosis are required. Moreover, they often exhibit modest sensitivity and hence significantly depend on later result confirmation in central or reference laboratories. The impressive advances observed in recent years in materials sciences and in nanotechnology, as well as in nucleic-acid synthesis and engineering, have led to an outburst of new in-the-bench and prototype tests for nucleic-acid testing towards point-of-care diagnosis of genetic and infectious diseases. Manufacturing, commercial, regulatory, and technical nature issues for field applicability more likely have hindered their wider entrance into veterinary medicine and practice than have fundamental science gaps. This chapter begins by outlining the current situation, requirements, difficulties, and perspectives of point-of-care tests for diagnosing diseases of veterinary interest. Nucleic-acid testing, particularly for the point of care, is addressed subsequently. A range of valuable signal transduction mechanisms commonly employed in proof-of-concept schemes and techniques born on the analytical chemistry laboratories are also described. As the essential core of this chapter, sections dedicated to the principles and applications of microfluidics, lab-on-a-chip, and nanotechnology for the development of point-of-care tests are presented. Microdevices already applied or under development for application in field diagnosis of animal diseases are reviewed.

  3. Features of the photometry of the superposition of coherent vector electromagnetic waves

    NASA Astrophysics Data System (ADS)

    Sakhnovskyj, Mykhajlo Yu.; Tymochko, Bogdan M.; Rudeichuk, Volodymyr M.

    2018-01-01

    In the paper we propose a general approach to the calculation of the forming the intensity and polarization fields of the superposition of arbitrary coherent vector beams at points of a given reference plane. The method of measuring photometric parameters of a field, formed in the neighborhood of an arbitrary point of the plane of analysis by minimizing the values of irradiance in the vicinity of a given point (method of zero-amplitude at a given point), which is achieved by superimposing on it the reference wave with the controlled values of intensity, polarization state, phase, and angle of incidence, is proposed.

  4. Handheld tools assess medical necessity at the point of care.

    PubMed

    Pollard, Dan

    2002-01-01

    An emerging strategy to manage financial risk in clinical practice is to involve the physician at the point of care. Using handheld technology, encounter-specific information along with medical necessity policy can be presented to physicians allowing them to integrate it into their medical decision-making process. Three different strategies are discussed: reference books or paper encounter forms, electronic reference tools, and integrated process tools. The electronic reference tool strategy was evaluated and showed a return on investment exceeding 1200% due to reduced overhead costs associated with rework of claim errors.

  5. Predictors of early person reference development: maternal language input, attachment and neurodevelopmental markers.

    PubMed

    Lemche, Erwin; Joraschky, Peter; Klann-Delius, Gisela

    2013-12-01

    In a longitudinal natural language development study in Germany, the acquisition of verbal symbols for present persons, absent persons, inanimate things and the mother-toddler dyad was investigated. Following the notion that verbal referent use is more developed in ostensive contexts, symbolic play situations were coded for verbal person reference by means of noun and pronoun use. Depending on attachment classifications at twelve months of age, effects of attachment classification and maternal language input were studied up to 36 months in four time points. Hierarchical regression analyses revealed that, except for mother absence, maternal verbal referent input rates at 17 and 36 months were stronger predictors for all referent types than any of the attachment organizations, or any other social or biological predictor variable. Attachment effects accounted for up to 9.8% of unique variance proportions in the person reference variables. Perinatal and familial measures predicted person references dependent on reference type. The results of this investigation indicate that mother-reference, self-reference and thing-reference develop in similar quantities measured from the 17-month time point, but are dependent of attachment quality. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Genetics Home Reference: ethylmalonic encephalopathy

    MedlinePlus

    ... Tiranti V, Zeviani M. Altered sulfide (H(2)S) metabolism in ethylmalonic encephalopathy. Cold Spring Harb Perspect Biol. 2013 Jan 1;5(1):a011437. doi: 10.1101/cshperspect.a011437. Review. Citation on PubMed or Free article on PubMed Central More from Genetics Home Reference ...

  7. Automatic identification of the reference system based on the fourth ventricular landmarks in T1-weighted MR images.

    PubMed

    Fu, Yili; Gao, Wenpeng; Chen, Xiaoguang; Zhu, Minwei; Shen, Weigao; Wang, Shuguo

    2010-01-01

    The reference system based on the fourth ventricular landmarks (including the fastigial point and ventricular floor plane) is used in medical image analysis of the brain stem. The objective of this study was to develop a rapid, robust, and accurate method for the automatic identification of this reference system on T1-weighted magnetic resonance images. The fully automated method developed in this study consisted of four stages: preprocessing of the data set, expectation-maximization algorithm-based extraction of the fourth ventricle in the region of interest, a coarse-to-fine strategy for identifying the fastigial point, and localization of the base point. The method was evaluated on 27 Brain Web data sets qualitatively and 18 Internet Brain Segmentation Repository data sets and 30 clinical scans quantitatively. The results of qualitative evaluation indicated that the method was robust to rotation, landmark variation, noise, and inhomogeneity. The results of quantitative evaluation indicated that the method was able to identify the reference system with an accuracy of 0.7 +/- 0.2 mm for the fastigial point and 1.1 +/- 0.3 mm for the base point. It took <6 seconds for the method to identify the related landmarks on a personal computer with an Intel Core 2 6300 processor and 2 GB of random-access memory. The proposed method for the automatic identification of the reference system based on the fourth ventricular landmarks was shown to be rapid, robust, and accurate. The method has potentially utility in image registration and computer-aided surgery.

  8. The limits of boundaries: unpacking localization and cognitive mapping relative to a boundary.

    PubMed

    Zhou, Ruojing; Mou, Weimin

    2018-05-01

    Previous research (Zhou, Mou, Journal of Experimental Psychology: Learning, Memory and Cognition 42(8):1316-1323, 2016) showed that learning individual locations relative to a single landmark, compared to learning relative to a boundary, led to more accurate inferences of inter-object spatial relations (cognitive mapping of multiple locations). Following our past findings, the current study investigated whether the larger number of reference points provided by a homogeneous circular boundary, as well as less accessible knowledge of direct spatial relations among the multiple reference points, would lead to less effective cognitive mapping relative to the boundary. Accordingly, we manipulated (a) the number of primary reference points (one segment drawn from a circular boundary, four such segments, vs. the complete boundary) available when participants were localizing four objects sequentially (Experiment 1) and (b) the extendedness of each of the four segments (Experiment 2). The results showed that cognitive mapping was the least accurate in the whole boundary condition. However, expanding each of the four segments did not affect the accuracy of cognitive mapping until the four were connected to form a continuous boundary. These findings indicate that when encoding locations relative to a homogeneous boundary, participants segmented the boundary into differentiated pieces and subsequently chose the most informative local part (i.e., the segment closest in distance to one location) as the primary reference point for a particular location. During this process, direct spatial relations among the reference points were likely not attended to. These findings suggest that people might encode and represent bounded space in a fragmented fashion when localizing within a homogeneous boundary.

  9. Method of recertifying a loaded bearing member

    NASA Technical Reports Server (NTRS)

    Allison, Sidney G. (Inventor)

    1992-01-01

    A method is described of recertifying a loaded bearing member using ultrasound testing to compensate for different equipment configurations and temperature conditions. The standard frequency F1 of a reference block is determined via an ultrasonic tone burst generated by a first pulsed phased locked loop (P2L2) equipment configuration. Once a lock point number S is determined for F1, the reference frequency F1a of the reference block is determined at this lock point number via a second P2L2 equipment configuration to permit an equipment offset compensation factor Fo1=((F1-F1a)/F1)(1000000) to be determined. Next, a reference frequency F2 of the unloaded bearing member is determined using a second P2L2 equipment configuration and is then compensated for equipment offset errors via the relationship F2+F2(Fo1)/1000000. A lock point number b is also determined for F2. A resonant frequency F3 is determined for the reference block using a third P2L2 equipment configuration to determine a second offset compensation factor F02=((F1-F3)/F1) 1000000. Next the resonant frequency F4 of the loaded bearing member is measured at lock point number b via the third P2L2 equipment configuration and the bolt load determined by the relationship (-1000000)CI(((F2-F4)/F2)-Fo2), wherein CI is a factor correlating measured frequency shift to the applied load. Temperature compensation is also performed at each point in the process.

  10. Exposure and effects of perfluoroalkyl compounds on tree swallows nesting at Lake Johanna in east central Minnesota, USA

    USGS Publications Warehouse

    Custer, Christine M.; Custer, Thomas W.; Schoenfuss, Heiko L.; Poganski, Beth H.; Solem, Laura

    2012-01-01

    Tree swallow (Tachycineta bicolor) samples were collected at a reference lake and a nearby lake (Lake Johanna) in east central Minnesota, USA contaminated with perfluorinated carboxylic and sulfonic acids. Tissues were analyzed for a suite of 13 perfluoroalkyl compounds (PFCs) to quantify exposure and to determine if there was an association between egg concentrations of PFCs and reproductive success of tree swallows. Concentrations of perfluoroocatane sulfonate (PFOS) were elevated in all tree swallow tissues from Lake Johanna compared to tissues collected at the reference lake. Other PFCs, except for two, were elevated in blood plasma at Lake Johanna compared to the reference lake. PFOS was the dominant PFC (>75%) at Lake Johanna, but accounted for <50% of total PFCs at the reference lake. There was a negative association between concentrations of PFOS in eggs and hatching success. Reduced hatching success was associated with PFOS levels as low as 150 ng/g wet weight.

  11. Hematology and plasma biochemistry values for the giant garter snake (Thamnophis gigas) and valley garter snake (Thamnophis sirtalis fitchi) in the Central Valley of California.

    PubMed

    Wack, Raymund F; Hansen, Eric; Small, Marilyn; Poppenga, Robert; Bunn, David; Johnson, Christine K

    2012-04-01

    Hematology and plasma biochemistry parameters are useful in the assessment and management of threatened and endangered species. Although reference ranges are readily available for many mammalian species, reference ranges for snakes are lacking for most species. We determined hematology and plasma biochemistry reference ranges for giant garter snakes (Thamnophis gigas) and valley garter snakes (Thamnophis sirtalis fitchi) living in four management areas in the Central Valley of California. White blood cell, heterophil, lymphocyte, and azurophil counts in giant garter snakes were approximately twice the values of valley garter snakes. Statistically significant differences in aspartate aminotransferase, globulin, and potassium between the two species did not appear clinically significant. No significant differences were found in the measured parameters between male and female giant garter snakes. Some differences were found among collection sites. These reference ranges provide baseline data for comparisons over time and between collection sites.

  12. Impact of bias correction and downscaling through quantile mapping on simulated climate change signal: a case study over Central Italy

    NASA Astrophysics Data System (ADS)

    Sangelantoni, Lorenzo; Russo, Aniello; Gennaretti, Fabio

    2018-02-01

    Quantile mapping (QM) represents a common post-processing technique used to connect climate simulations to impact studies at different spatial scales. Depending on the simulation-observation spatial scale mismatch, QM can be used for two different applications. The first application uses only the bias correction component, establishing transfer functions between observations and simulations at similar spatial scales. The second application includes a statistical downscaling component when point-scale observations are considered. However, knowledge of alterations to climate change signal (CCS) resulting from these two applications is limited. This study investigates QM impacts on the original temperature and precipitation CCSs when applied according to a bias correction only (BC-only) and a bias correction plus downscaling (BC + DS) application over reference stations in Central Italy. BC-only application is used to adjust regional climate model (RCM) simulations having the same resolution as the observation grid. QM BC + DS application adjusts the same simulations to point-wise observations. QM applications alter CCS mainly for temperature. BC-only application produces a CCS of the median 1 °C lower than the original ( 4.5 °C). BC + DS application produces CCS closer to the original, except over the summer 95th percentile, where substantial amplification of the original CCS resulted. The impacts of the two applications are connected to the ratio between the observed and the simulated standard deviation (STD) of the calibration period. For the precipitation, original CCS is essentially preserved in both applications. Yet, calibration period STD ratio cannot predict QM impact on the precipitation CCS when simulated STD and mean are similarly misrepresented.

  13. Artificial gravity as a countermeasure in long-duration space flight

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; DiZio, P.

    2000-01-01

    Long-duration exposure to weightlessness results in bone demineralization, muscle atrophy, cardiovascular deconditioning, altered sensory-motor control, and central nervous system reorganizations. Exercise countermeasures and body loading methods so far employed have failed to prevent these changes. A human mission to Mars might last 2 or 3 years and without effective countermeasures could result in dangerous levels of bone and muscle loss. Artificial gravity generated by rotation of an entire space vehicle or of an inner chamber could be used to prevent structural changes. Some of the physical characteristics of rotating environments are outlined along with their implications for human performance. Artificial gravity is the centripetal force generated in a rotating vehicle and is proportional to the product of the square of angular velocity and the radius of rotation. Thus, for a particular g-level, there is a tradeoff between velocity of rotation and radius. Increased radius is vastly more expensive to achieve than velocity, so it is important to know the highest rotation rates to which humans can adapt. Early studies suggested that 3 rpm might be the upper limit because movement control and orientation were disrupted at higher velocities and motion sickness and chronic fatigue were persistent problems. Recent studies, however, are showing that, if the terminal velocity is achieved over a series of gradual steps and many body movements are made at each dwell velocity, then full adaptation of head, arm, and leg movements is possible. Rotation rates as high as 7.5-10 rpm are likely feasible. An important feature of the new studies is that they provide compelling evidence that equilibrium point theories of movement control are inadequate. The central principles of equilibrium point theories lead to the equifinality prediction, which is violated by movements made in rotating reference frames. Copyright 2000 Wiley-Liss, Inc.

  14. Centralization vs. Decentralization: A Location Analysis Approach for Librarians

    ERIC Educational Resources Information Center

    Raffel, Jeffrey; Shishko, Robert

    1972-01-01

    An application of location theory to the question of centralized versus decentralized library facilities for a university, with relevance for special libraries is presented. The analysis provides models for a single library, for two or more libraries, or for decentralized facilities. (6 references) (Author/NH)

  15. 47 CFR 73.208 - Reference points and distance computations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...

  16. 47 CFR 73.208 - Reference points and distance computations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SERVICES RADIO BROADCAST SERVICES FM Broadcast Stations § 73.208 Reference points and distance computations... filed no later than: (i) The last day of a filing window if the application is for a new FM facility or...(d) and 73.3573(e) if the application is for a new FM facility or a major change in the reserved band...

  17. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    PubMed

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Media Criticism Group Speech

    ERIC Educational Resources Information Center

    Ramsey, E. Michele

    2004-01-01

    Objective: To integrate speaking practice with rhetorical theory. Type of speech: Persuasive. Point value: 100 points (i.e., 30 points based on peer evaluations, 30 points based on individual performance, 40 points based on the group presentation), which is 25% of course grade. Requirements: (a) References: 7-10; (b) Length: 20-30 minutes; (c)…

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kang, Hyun-Ju; Chung, Chin-Wook, E-mail: joykang@hanyang.ac.kr; Choi, Hyeok

    A modified central difference method (MCDM) is proposed to obtain the electron energy distribution functions (EEDFs) in single Langmuir probes. Numerical calculation of the EEDF with MCDM is simple and has less noise. This method provides the second derivatives at a given point as the weighted average of second order central difference derivatives calculated at different voltage intervals, weighting each by the square of the interval. In this paper, the EEDFs obtained from MCDM are compared to those calculated via the averaged central difference method. It is found that MCDM effectively suppresses the noises in the EEDF, while the samemore » number of points are used to calculate of the second derivative.« less

  20. Decentralized model reference adaptive control of large flexible structures

    NASA Technical Reports Server (NTRS)

    Lee, Fu-Ming; Fong, I-Kong; Lin, Yu-Hwan

    1988-01-01

    A decentralized model reference adaptive control (DMRAC) method is developed for large flexible structures (LFS). The development follows that of a centralized model reference adaptive control for LFS that have been shown to be feasible. The proposed method is illustrated using a simply supported beam with collocated actuators and sensors. Results show that the DMRAC can achieve either output regulation or output tracking with adequate convergence, provided the reference model inputs and their time derivatives are integrable, bounded, and approach zero as t approaches infinity.

  1. Global chaotization of fluid particle trajectories in a sheared two-layer two-vortex flow.

    PubMed

    Ryzhov, Evgeny A; Koshel, Konstantin V

    2015-10-01

    In a two-layer quasi-geostrophic approximation, we study the irregular dynamics of fluid particles arising due to two interacting point vortices embedded in a deformation flow consisting of shear and rotational components. The two vortices are arranged within the bottom layer, but an emphasis is on the upper-layer fluid particle motion. Vortices moving in one layer induce stirring of passive scalars in the other layer. This is of interest since point vortices induce singular velocity fields in the layer they belong to; however, in the other layer, they induce regular velocity fields that generally result in a change in passive particle stirring. If the vortices are located at stagnation points, there are three different types of the fluid flow. We examine how properties of each flow configuration are modified if the vortices are displaced from the stagnation points and thus circulate in the immediate vicinity of these points. To that end, an analysis of the steady-state configurations is presented with an emphasis on the frequencies of fluid particle oscillations about the elliptic stagnation points. Asymptotic relations for the vortex and fluid particle zero-oscillation frequencies are derived in the vicinity of the corresponding elliptic points. By comparing the frequencies of fluid particles with the ones of the vortices, relations between the parameters that lead to enhanced stirring of fluid particles are established. It is also demonstrated that, if the central critical point is elliptic, then the fluid particle trajectories in its immediate vicinity are mostly stable making it harder for the vortex perturbation to induce stirring. Change in the type of the central point to a hyperbolic one enhances drastically the size of the chaotic dynamics region. Conditions on the type of the central critical point also ensue from the derived asymptotic relations.

  2. Central retinal artery occlusion - rethinking retinal survival time.

    PubMed

    Tobalem, Stephan; Schutz, James S; Chronopoulos, Argyrios

    2018-04-18

    The critical time from onset of complete occlusion of the central retinal artery (CRA) to functionally significant inner retinal infarction represents a window of opportunity for treatment and also has medical-legal implications, particularly when central retinal artery occlusion (CRAO) complicates therapeutic interventions. Here, we review the evidence for time to infarction from complete CRAO and discuss the implications of our findings. A Medline search was performed using each of the terms "central retinal artery occlusion", "retinal infarction", "retinal ischemia", and "cherry red spot" from 1970 to the present including articles in French and German. All retrieved references as well as their reference lists were screened for relevance. An Internet search using these terms was also performed to look for additional references. We find that the experimental evidence showing that inner retinal infarction occurs after 90-240 min of total CRAO, which is the interval generally accepted in the medical literature and practice guidelines, is flawed in important ways. Moreover, the retinal ganglion cells, supplied by the CRA, are part of the central nervous system which undergoes infarction after non-perfusion of 12-15 min or less. Retinal infarction is most likely to occur after only 12-15 min of complete CRAO. This helps to explain why therapeutic maneuvers for CRAO are often ineffective. Nevertheless, many CRAOs are incomplete and may benefit from therapy after longer intervals. To try to avoid retinal infarcton from inadvertent ocular compression by a headrest during prone anesthesia, the eyes should be checked at intervals of less than 15'.

  3. China Report: Political, Sociological and Military Affairs. No. 440

    DTIC Science & Technology

    1983-07-26

    is comprised of 25 persons. The chairman of the commmssion is Zeng Tianjie [2582 1131 4634], and vice chairmen are Zuo Hongtao [1563 3163 3447...Comrade Qian Yunlu pointed out: Speeding up the development of broadcasting and television work is a demand raised by the central leadership and the...contributions to achieving them. Comrade Qian Yunlu said: The secretariat of the CPC Central Committee has pointed out that radio and television are the most

  4. Side Effects in Time Discounting Procedures: Fixed Alternatives Become the Reference Point

    PubMed Central

    2016-01-01

    Typical research on intertemporal choice utilizes a two-alternative forced choice (2AFC) paradigm requiring participants to choose between a smaller sooner and larger later payoff. In the adjusting-amount procedure (AAP) one of the alternatives is fixed and the other is adjusted according to particular choices made by the participant. Such a method makes the alternatives unequal in status and is speculated to make the fixed alternative a reference point for choices, thereby affecting the decision made. The current study shows that fixing different alternatives in the AAP influences discount rates in intertemporal choices. Specifically, individuals’ (N = 283) choices were affected to just the same extent by merely fixing an alternative as when choices were preceded by scenarios explicitly imposing reference points. PMID:27768759

  5. Maritime Claims Reference Manual

    DTIC Science & Technology

    1990-07-12

    line connecting the following points: Cap de la Morsetta--Pointe des Scoglietti-llot de Gargalo--Cap Rosso --Pointe d’Omignis--Cap de Feno (Golfe de...Tg. Rua. 127. 09 - 45.5 S 119 - 11.6 T Tg. Mambo. 128. 09 - 40.5 S 119 - 02.0 T 129. 08 - 53.6 S 118 - 29.9 T Toro Doro. 2-229 REFERENCE CO-ORDINATES...8217 - 12013.40’) to Capo Linaro (42001.70’ - 11050.20’); From Civitavecchia beacon (42005.75’ - 11046.65’) to Isola Giannutri Punta del Capel Rosso

  6. Campaign-Style Measurements of Vertical Seafloor Deformation in the Cascadia Subduction Zone Using an Absolute Self-Calibrating Pressure Recorder

    NASA Astrophysics Data System (ADS)

    Cook, M. J.; Sasagawa, G. S.; Roland, E. C.; Schmidt, D. A.; Wilcock, W. S. D.; Zumberge, M. A.

    2017-12-01

    Seawater pressure can be used to measure vertical seafloor deformation since small seafloor height changes produce measurable pressure changes. However, resolving secular vertical deformation near subduction zones can be difficult due to pressure gauge drift. A typical gauge drift rate of about 10 cm/year exceeds the expected secular rate of 1 cm/year or less in Cascadia. The absolute self-calibrating pressure recorder (ASCPR) was developed to solve the issue of gauge drift by using a deadweight calibrator to make campaign-style measurements of the absolute seawater pressure. Pressure gauges alternate between observing the ambient seawater pressure and the deadweight calibrator pressure, which is an accurately known reference value, every 10-20 minutes for several hours. The difference between the known reference pressure and the observed seafloor pressure allows offsets and transients to be corrected to determine the true, absolute seafloor pressure. Absolute seafloor pressure measurements provide a great utility for geodetic deformation studies. The measurements provide instrument-independent, benchmark values that can be used far into the future as epoch points in long-term time series or as important calibration points for other continuous pressure records. The ASCPR was first deployed in Cascadia in 2014 and 2015, when seven concrete seafloor benchmarks were placed along a trench-perpendicular profile extending from 20 km to 105 km off the central Oregon coast. Two benchmarks have ASCPR measurements that span three years, one benchmark spans two years, and four benchmarks span one year. Measurement repeatability is currently 3 to 4 cm, but we anticipate accuracy on the order of 1 cm with improvements to the instrument metrology and processing tidal and non-tidal oceanographic signals.

  7. Accuracy of image guidance using free-breathing cone-beam computed tomography for stereotactic lung radiotherapy.

    PubMed

    Kamomae, Takeshi; Monzen, Hajime; Nakayama, Shinichi; Mizote, Rika; Oonishi, Yuuichi; Kaneshige, Soichiro; Sakamoto, Takashi

    2015-01-01

    Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the examinations. Reference point discrepancies between the MV X-ray beam and the CBCT system were calculated using a phantom device with a centrally mounted steel ball. The precision of manual image matching between the CBCT and the averaged intensity (AI) images restructured from four-dimensional CT (4DCT) was estimated with a respiratory motion phantom, as determined in evaluations by five independent operators. Reference point discrepancies between the MV X-ray beam and the CBCT image-guidance systems, categorized as left-right (LR), anterior-posterior (AP), and superior-inferior (SI), were 0.33 ± 0.09, 0.16 ± 0.07, and 0.05 ± 0.04 mm, respectively. The LR, AP, and SI values for residual errors from manual image matching were -0.03 ± 0.22, 0.07 ± 0.25, and -0.79 ± 0.68 mm, respectively. The accuracy of target position localization using the Vero4DRT system in our center was 1.07 ± 1.23 mm (2 SD). This study experimentally demonstrated the sufficient level of geometric accuracy using the free-breathing CBCT and the image-guidance system mounted on the Vero4DRT. However, the inter-observer variation and systematic localization error of image matching substantially affected the overall geometric accuracy. Therefore, when using the free-breathing CBCT images, careful consideration of image matching is especially important.

  8. Holocene relative sea levels of Bonaire (Leeward Antilles) - Evidence from circumlittoral sediment traps

    NASA Astrophysics Data System (ADS)

    Engel, Max; May, Simon Matthias; Brückner, Helmut

    2014-05-01

    Relative sea-level (RSL) rise in the near future represents one of the most serious coastal hazards worldwide, in particular in the Caribbean region where it may enhance negative effects from hurricane-induced flooding. RSL is a function of global (glacioeustasy, steric effect), regional (e.g. glacio-isostatic adjustment [GIA], gravitational effects inducing deformation of the earth, upper/lower mantle viscosity, etc.) and local (sediment compaction, tectonic uplift/subsidence) factors. Information on past RSL supports inferences on upper limits of ice shield ablation, estimates of anthropogenic contribution to historical and future RSL rise and calibration of rheological Earth models. We present the first Holocene RSL curve for the island of Bonaire in the southern Caribbean based on 42 14C datings from 20 sediment cores taken from nine different sedimentary archives along the coast. The sedimentary environment of each index point was linked to a palaeo-water depth based on literature and field observations. The index points trace a local RSL history of decelerating rise since 7000-6000 years ago and subsequent asymptotical approximation, similar to RSL curves from adjacent coasts of Curaςao and Venezuela. The results were compared to an existing reference model which considers global effects and regional GIA (including implications for geopotential). Even though the central and northwestern parts of Bonaire experienced slow tectonic uplift of up to 50 cm since the mid-Holocene and correction for compaction was applied, the new RSL curve for Bonaire runs slightly below the reference model which is probably due to sediment compaction in the investigated archives, collapse of cavities in the underlying limestone, or, at Boka Bartol, local-scale normal faulting (c. 1.5 mm/yr).

  9. Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

    PubMed

    Babu, Sumanth; Manjunath, Shaurya; Vajawat, Mayuri

    2016-01-01

    The aim of this in-vitro study was to assess the influence of shallow and deep palatal forms on the movement of teeth during the processing of complete denture prosthesis. Maxillary casts with shallow and deep palatal forms were selected and duplicated to make 10 casts of each palatal form. Base plates were constructed and teeth were arranged in their anatomic positions. Metal pins with true apex were placed on the central groove of the right and left first molars and one on the incisive papilla area as a reference point. Casts were scanned using i-CAT Vision Q 1.9 (i-CAT cone beam 3D dental imaging system by Imaging Sciences International, PA, USA), which has 360° rotational tomography. The distances between the apices of metallic pin inserts on the teeth and fitted point of reference were recorded in buccopalatal axes at waxed up stage, after deflasking, and after finishing and polishing. Results showed a statistically significant movement of teeth in shallow and deep palatal forms during all stages of complete denture processing. In shallow palatal form dentures, there was a significant tooth movement in palatal direction between Stages 1 and 2 (P ≤ 0.05) and buccal movement between Stages 2 and 3. In deep palatal form dentures, teeth showed a statistically significant (P ≤ 0.05) movement in buccal direction during all stages of denture processing. Teeth showed significant movement during processing of acrylic resin dentures. Overall, the movement of teeth in shallow palatal form dentures was in palatal direction, whereas in deep palatal form dentures, the movement of teeth was in buccal direction.

  10. Diagnosing Cervical Neoplasia in Rural Brazil Using a Mobile Van Equipped with In Vivo Microscopy: A Cluster-Randomized Community Trial.

    PubMed

    Hunt, Brady; Fregnani, José Humberto Tavares Guerreiro; Schwarz, Richard A; Pantano, Naitielle; Tesoni, Suelen; Possati-Resende, Júlio César; Antoniazzi, Marcio; de Oliveira Fonseca, Bruno; de Macêdo Matsushita, Graziela; Scapulatempo-Neto, Cristovam; Kerr, Ligia; Castle, Philip E; Schmeler, Kathleen; Richards-Kortum, Rebecca

    2018-06-01

    Cervical cancer is a leading cause of death in underserved areas of Brazil. This prospective randomized trial involved 200 women in southern/central Brazil with abnormal Papanicolaou tests. Participants were randomized by geographic cluster and referred for diagnostic evaluation either at a mobile van upon its scheduled visit to their local community, or at a central hospital. Participants in both arms underwent colposcopy, in vivo microscopy, and cervical biopsies. We compared rates of diagnostic follow-up completion between study arms, and also evaluated the diagnostic performance of in vivo microscopy compared with colposcopy. There was a 23% absolute and 37% relative increase in diagnostic follow-up completion rates for patients referred to the mobile van (102/117, 87%) compared with the central hospital (53/83, 64%; P = 0.0001; risk ratio = 1.37, 95% CI, 1.14-1.63). In 229 cervical sites in 144 patients, colposcopic examination identified sites diagnosed as cervical intraepithelial neoplasia grade 2 or more severe (CIN2+; 85 sites) with a sensitivity of 94% (95% CI, 87%-98%) and specificity of 50% (95% CI, 42%-58%). In vivo microscopy with real-time automated image analysis identified CIN2+ with a sensitivity of 92% (95% CI, 84%-97%) and specificity of 48% (95% CI, 40%-56%). Women referred to the mobile van were more likely to complete their diagnostic follow-up compared with those referred to a central hospital, without compromise in clinical care. In vivo microscopy in a mobile van provides automated diagnostic imaging with sensitivity and specificity similar to colposcopy. Cancer Prev Res; 11(6); 359-70. ©2018 AACR . ©2018 American Association for Cancer Research.

  11. Reconstruction method for fringe projection profilometry based on light beams.

    PubMed

    Li, Xuexing; Zhang, Zhijiang; Yang, Chen

    2016-12-01

    A novel reconstruction method for fringe projection profilometry, based on light beams, is proposed and verified by experiments. Commonly used calibration techniques require the parameters of projector calibration or the reference planes placed in many known positions. Obviously, introducing the projector calibration can reduce the accuracy of the reconstruction result, and setting the reference planes to many known positions is a time-consuming process. Therefore, in this paper, a reconstruction method without projector's parameters is proposed and only two reference planes are introduced. A series of light beams determined by the subpixel point-to-point map on the two reference planes combined with their reflected light beams determined by the camera model are used to calculate the 3D coordinates of reconstruction points. Furthermore, the bundle adjustment strategy and the complementary gray-code phase-shifting method are utilized to ensure the accuracy and stability. Qualitative and quantitative comparisons as well as experimental tests demonstrate the performance of our proposed approach, and the measurement accuracy can reach about 0.0454 mm.

  12. The Photogrammetry Cube

    NASA Technical Reports Server (NTRS)

    2008-01-01

    We can determine distances between objects and points of interest in 3-D space to a useful degree of accuracy from a set of camera images by using multiple camera views and reference targets in the camera s field of view (FOV). The core of the software processing is based on the previously developed foreign-object debris vision trajectory software (see KSC Research and Technology 2004 Annual Report, pp. 2 5). The current version of this photogrammetry software includes the ability to calculate distances between any specified point pairs, the ability to process any number of reference targets and any number of camera images, user-friendly editing features, including zoom in/out, translate, and load/unload, routines to help mark reference points with a Find function, while comparing them with the reference point database file, and a comprehensive output report in HTML format. In this system, scene reference targets are replaced by a photogrammetry cube whose exterior surface contains multiple predetermined precision 2-D targets. Precise measurement of the cube s 2-D targets during the fabrication phase eliminates the need for measuring 3-D coordinates of reference target positions in the camera's FOV, using for example a survey theodolite or a Faroarm. Placing the 2-D targets on the cube s surface required the development of precise machining methods. In response, 2-D targets were embedded into the surface of the cube and then painted black for high contrast. A 12-inch collapsible cube was developed for room-size scenes. A 3-inch, solid, stainless-steel photogrammetry cube was also fabricated for photogrammetry analysis of small objects.

  13. Detection of Dry Intrusion on Water Vapor Images Over Central Europe - June 2010 TO September 2011

    NASA Astrophysics Data System (ADS)

    Novotny, J.; Dejmal, K.; Hudec, F.; Kolar, P.

    2016-06-01

    The knowledge of evaluation of the intensity of cyclogenesis which could be connected with the weather having a significant impact on Earth's surface is quite useful. If, as one of the basic assumptions, the existence of connection between dry intrusions, dry bands, tropopause height and warm dark areas distribution on water vapor images (WV images) is considered, it is possible to set up a method of detecting dry intrusions on searching and tracking areas with higher brightness temperature compared with the surrounding environment. This paper covers the period between June 2010 and September 2011 over Central Europe. The ISIS method (Instrument de Suivi dans I'Imagerie satellitaire), originally developed for detection of cold cloud tops, was used as an initial ideological point. Subsequently, this method was modified by Michel and Bouttier for usage on WV images. Some of the applied criteria and parameters were chosen with reference to the results published by Michel and Bouttier as well as by Novotny. The procedure can be divided into two steps: detection of warm areas and their tracking. Cases of detection of areas not evidently connected with dry intrusions can be solved by filtering off based on the connection between detected warm areas to the cyclonic side of jet streams and significant lowering of the tropopause.

  14. Bioactive Potential of Marine Macroalgae from the Central Red Sea (Saudi Arabia) Assessed by High-Throughput Imaging-Based Phenotypic Profiling

    PubMed Central

    Kremb, Stephan; Müller, Constanze; Schmitt-Kopplin, Philippe; Voolstra, Christian R.

    2017-01-01

    Marine algae represent an important source of novel natural products. While their bioactive potential has been studied to some extent, limited information is available on marine algae from the Red Sea. This study aimed at the broad discovery of new bioactivities from a collection of twelve macroalgal species from the Central Red Sea. We used imaging-based High-Content Screening (HCS) with a diverse spectrum of cellular markers for detailed cytological profiling of fractionated algal extracts. The cytological profiles for 3 out of 60 algal fractions clustered closely to reference inhibitors and showed strong inhibitory activities on the HIV-1 reverse transcriptase in a single-enzyme biochemical assay, validating the suggested biological target. Subsequent chemical profiling of the active fractions of two brown algal species by ultra-high resolution mass spectrometry (FT-ICR-MS) revealed possible candidate molecules. A database query of these molecules led us to groups of compounds with structural similarities, which are suggested to be responsible for the observed activity. Our work demonstrates the versatility and power of cytological profiling for the bioprospecting of unknown biological resources and highlights Red Sea algae as a source of bioactives that may serve as a starting point for further studies. PMID:28335513

  15. [Antiretroviral drug supply in Argentina: National Program to Combat Human Retroviruses, AIDS, and STDs].

    PubMed

    Colautti, Marisel; Luppi, Irene; Salamano, Mercedes; Traverso, María Luz; Botta, Carina; Palchik, Valeria

    2009-01-01

    To evaluate the supply cycle of antiretroviral (ARV) drugs, overseen by the National Program to Combat Human Retroviruses, AIDS, and STDs, through its order fulfillment indicators, and to obtain input from supply chain stakeholders. A study was carried out from April-September 2005 in the pharmacies of two hospitals in Rosario, Argentina, involving both a quantitative analysis of indicators and secondary sources and a qualitative evaluation using semistructured interviews. The indicators reveal the impact that interruptions in ARV supply stream from the Program (central level) have and the overstocking that takes place at the pharmacies (local level) to manage the shortages. Changes in ARV treatment account for over 50% of the prescriptions. Fulfillments fall short of the reference value. The interviewees shared possible strategies for overcoming the communication gaps between levels, for building-up stock, for guaranteeing availability, and for shortening waiting times; reached informal agreements to deal with the lack of policies and the shortage of staff; acknowledged the challenges facing the jurisdictions (central, intermediate, and local/community); and recognized local efforts to improve management. These challenges could be the starting point for building teams to work on effectively decentralizing the entire supply chain and allowing the Program to fulfill its much-needed oversight role.

  16. Role of social support in cognitive function among elders.

    PubMed

    Zhu, Shuzhen; Hu, Jie; Efird, Jimmy T

    2012-08-01

    To examine cognitive function and its relationships to demographic characteristics and social support among elders in central China. Cognitive decline is prevalent among elders. Few studies have explored the relationship between social support and cognitive function among elders. A cross-sectional, descriptive correlational study. A quasi-random, point of reference sample of 120 elders residing in central China was recruited for study. Instruments used included a: Socio-demographic Questionnaire, the Multidimensional Scale on Perceived Social Support and the Mini-Mental State Examination. Hierarchical multiple regression was performed to examine the relationships among demographic variables, social support and cognitive function. Age, education and social support accounted for 45·2% of the variance in cognitive function. Family support was the strongest predictor of cognitive function. Elders who had higher educational levels and more family support had better cognitive function. Relevance to clinical practice.  Community healthcare providers should consolidate social support among elders in China and use family support interventions to reduce or delay cognitive decline, especially among those of increased age who are illiterate. Elders who had higher educational level and more family support had better cognitive function levels. Interventions that include family support are needed to improve cognitive function among elders in China. © 2012 Blackwell Publishing Ltd.

  17. Costs of health IT: beginning to understand the financial impact of a dental school EHR.

    PubMed

    Spallek, Heiko; Johnson, Lynn; Kerr, Joseph; Rankin, David

    2014-11-01

    Health Information Technology (Health IT) constitutes an integral component of the operations of most academic dental institutions nowadays. However, the expenses associated with the acquisition and the ongoing maintenance of these complex systems have often been buried among costs for other electronic infrastructure systems, distributed across various cost centers including unmeasured central campus support, covered centrally and therefore difficult to quantify, and spread over years, denying school administrators a clear understanding of the resources that have been dedicated to Health IT. The aim of this study was to understand the financial impact of Health IT at four similar U.S. dental schools: two schools using a purchased Electronic Health Record (EHR), and two schools that developed their own EHR. For these schools, the costs of creating ($2.5 million) and sustaining ($174,000) custom EHR software were significantly higher than acquiring ($500,000) and sustaining ($121,000) purchased software. These results are based on historical data and should not be regarded as a gold standard for what a complete Health IT suite should cost. The presented data are intended to inform school administrators about the myriad of costs associated with Health IT and give them a point of reference when comparing costs or making estimates for implementation projects.

  18. Bioactive Potential of Marine Macroalgae from the Central Red Sea (Saudi Arabia) Assessed by High-Throughput Imaging-Based Phenotypic Profiling.

    PubMed

    Kremb, Stephan; Müller, Constanze; Schmitt-Kopplin, Philippe; Voolstra, Christian R

    2017-03-20

    Marine algae represent an important source of novel natural products. While their bioactive potential has been studied to some extent, limited information is available on marine algae from the Red Sea. This study aimed at the broad discovery of new bioactivities from a collection of twelve macroalgal species from the Central Red Sea. We used imaging-based High-Content Screening (HCS) with a diverse spectrum of cellular markers for detailed cytological profiling of fractionated algal extracts. The cytological profiles for 3 out of 60 algal fractions clustered closely to reference inhibitors and showed strong inhibitory activities on the HIV-1 reverse transcriptase in a single-enzyme biochemical assay, validating the suggested biological target. Subsequent chemical profiling of the active fractions of two brown algal species by ultra-high resolution mass spectrometry (FT-ICR-MS) revealed possible candidate molecules. A database query of these molecules led us to groups of compounds with structural similarities, which are suggested to be responsible for the observed activity. Our work demonstrates the versatility and power of cytological profiling for the bioprospecting of unknown biological resources and highlights Red Sea algae as a source of bioactives that may serve as a starting point for further studies.

  19. Neural mechanisms of attentional control in mindfulness meditation

    PubMed Central

    Malinowski, Peter

    2013-01-01

    The scientific interest in meditation and mindfulness practice has recently seen an unprecedented surge. After an initial phase of presenting beneficial effects of mindfulness practice in various domains, research is now seeking to unravel the underlying psychological and neurophysiological mechanisms. Advances in understanding these processes are required for improving and fine-tuning mindfulness-based interventions that target specific conditions such as eating disorders or attention deficit hyperactivity disorders. This review presents a theoretical framework that emphasizes the central role of attentional control mechanisms in the development of mindfulness skills. It discusses the phenomenological level of experience during meditation, the different attentional functions that are involved, and relates these to the brain networks that subserve these functions. On the basis of currently available empirical evidence specific processes as to how attention exerts its positive influence are considered and it is concluded that meditation practice appears to positively impact attentional functions by improving resource allocation processes. As a result, attentional resources are allocated more fully during early processing phases which subsequently enhance further processing. Neural changes resulting from a pure form of mindfulness practice that is central to most mindfulness programs are considered from the perspective that they constitute a useful reference point for future research. Furthermore, possible interrelations between the improvement of attentional control and emotion regulation skills are discussed. PMID:23382709

  20. Neural mechanisms of attentional control in mindfulness meditation.

    PubMed

    Malinowski, Peter

    2013-01-01

    The scientific interest in meditation and mindfulness practice has recently seen an unprecedented surge. After an initial phase of presenting beneficial effects of mindfulness practice in various domains, research is now seeking to unravel the underlying psychological and neurophysiological mechanisms. Advances in understanding these processes are required for improving and fine-tuning mindfulness-based interventions that target specific conditions such as eating disorders or attention deficit hyperactivity disorders. This review presents a theoretical framework that emphasizes the central role of attentional control mechanisms in the development of mindfulness skills. It discusses the phenomenological level of experience during meditation, the different attentional functions that are involved, and relates these to the brain networks that subserve these functions. On the basis of currently available empirical evidence specific processes as to how attention exerts its positive influence are considered and it is concluded that meditation practice appears to positively impact attentional functions by improving resource allocation processes. As a result, attentional resources are allocated more fully during early processing phases which subsequently enhance further processing. Neural changes resulting from a pure form of mindfulness practice that is central to most mindfulness programs are considered from the perspective that they constitute a useful reference point for future research. Furthermore, possible interrelations between the improvement of attentional control and emotion regulation skills are discussed.

  1. An Account of Old English Stress.

    ERIC Educational Resources Information Center

    McCully, C. B.; Hogg, R. M.

    1990-01-01

    An analysis of stress patterns in Old English, from the perspective of a framework based on lexicalist metrical phonology, indicates that there was a central Old English stress rule that operated from left-to-right, in contrast to to the central rule for present day English. (46 references) (Author/CB)

  2. 75 FR 81440 - Establishment of Class E Airspace; Central City, NE

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-28

    ... this action to enhance the safety and management of Instrument Flight Rule (IFR) operations at the... airspace at Central City, NE, to accommodate new Area Navigation (RNAV) Standard Instrument Approach... this incorporation by reference action under 1 CFR part 51, subject to the annual revision of FAA Order...

  3. 29 CFR 100.614 - Collection by administrative offset.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... conducted more than 10 years after the Government's right to collect the claim or debt first accrued. (b) Mandatory centralized offset. (1) The NLRB is required to refer past due legally enforceable, nontax debts... centralized administrative offset is not available or appropriate to collect past due legally enforceable...

  4. USING REGIONAL EXPOSURE CRITERIA AND UPSTREAM REFERENCE DATA TO CHARACTERIZE SPATIAL AND TEMPORAL EXPOSURES TO CHEMICAL CONTAMINANTS

    EPA Science Inventory

    Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a baseline of fish from refer...

  5. USING REGIONAL EXPOSURE CRITERIA AND UPSTREAM REFERENCE DATA TO CHARACTERIZE SPATIAL AND TEMPORAL EXPOSURES TO CHEMICAL CONTAMINANTS

    EPA Science Inventory

    Analyses of biomarkers in fish were used to evaluate exposures among locations and across time. Two types of references were used for comparison, an upstream reference sample remote from known point sources and regional exposure criteria derived from a basline of fish from refere...

  6. The SPQR experiment: detecting damage to orbiting spacecraft with ground-based telescopes

    NASA Astrophysics Data System (ADS)

    Paolozzi, Antonio; Porfilio, Manfredi; Currie, Douglas G.; Dantowitz, Ronald F.

    2007-09-01

    The objective of the Specular Point-like Quick Reference (SPQR) experiment was to evaluate the possibility of improving the resolution of ground-based telescopic imaging of manned spacecraft in orbit. The concept was to reduce image distortions due to atmospheric turbulence by evaluating the Point Spread Function (PSF) of a point-like light reference and processing the spacecraft image accordingly. The target spacecraft was the International Space Station (ISS) and the point-like reference was provided by a laser beam emitted by the ground station and reflected back to the telescope by a Cube Corner Reflector (CCR) mounted on an ISS window. The ultimate objective of the experiment was to demonstrate that it is possible to image spacecraft in Low Earth Orbit (LEO) with a resolution of 20 cm, which would have probably been sufficient to detect the damage which caused the Columbia disaster. The experiment was successfully performed from March to May 2005. The paper provides an overview of the SPQR experiment.

  7. Alternative Methods for Estimating Plane Parameters Based on a Point Cloud

    NASA Astrophysics Data System (ADS)

    Stryczek, Roman

    2017-12-01

    Non-contact measurement techniques carried out using triangulation optical sensors are increasingly popular in measurements with the use of industrial robots directly on production lines. The result of such measurements is often a cloud of measurement points that is characterized by considerable measuring noise, presence of a number of points that differ from the reference model, and excessive errors that must be eliminated from the analysis. To obtain vector information points contained in the cloud that describe reference models, the data obtained during a measurement should be subjected to appropriate processing operations. The present paperwork presents an analysis of suitability of methods known as RANdom Sample Consensus (RANSAC), Monte Carlo Method (MCM), and Particle Swarm Optimization (PSO) for the extraction of the reference model. The effectiveness of the tested methods is illustrated by examples of measurement of the height of an object and the angle of a plane, which were made on the basis of experiments carried out at workshop conditions.

  8. First impressions and beyond: marketing your practice in touch points--Part I.

    PubMed

    Bisera, Cheryl

    2012-01-01

    Often medical administrators or providers call in a marketing expert when they feel the practice is lacking the growth they want. What's on their mind is usually how to bring in more patients, and they automatically look to external marketing strategies. However, one of the most important elements to successfully marketing a practice is making sure you haven't created a turnstile, where new patients are coming often but not returning or being converted into loyal, referring patients. When new patients are going as quickly as they are coming, you aren't building solid growth. Loyal, referring patients are powerful marketing assets-they are in the community speaking good of you and your practice from first-hand experience. You can create this atmosphere of loyal, referring patients by providing positive touch points that fulfill the needs of your patients. Touch points are the groundwork supporting other types of marketing. This article covers three important touch points that are crucial to a positive patient experience.

  9. INTERIOR FROM MEZZANINE LEVEL OF CENTRAL SECTION, VIEW FACING WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR FROM MEZZANINE LEVEL OF CENTRAL SECTION, VIEW FACING WEST. - Naval Air Station Barbers Point, Aircraft Storehouse, Between Midway & Card Streets at Enterprise Avenue intersection, Ewa, Honolulu County, HI

  10. Circular common-path point diffraction interferometer.

    PubMed

    Du, Yongzhao; Feng, Guoying; Li, Hongru; Vargas, J; Zhou, Shouhuan

    2012-10-01

    A simple and compact point-diffraction interferometer with circular common-path geometry configuration is developed. The interferometer is constructed by a beam-splitter, two reflection mirrors, and a telescope system composed by two lenses. The signal and reference waves travel along the same path. Furthermore, an opaque mask containing a reference pinhole and a test object holder or test window is positioned in the common focal plane of the telescope system. The object wave is divided into two beams that take opposite paths along the interferometer. The reference wave is filtered by the reference pinhole, while the signal wave is transmitted through the object holder. The reference and signal waves are combined again in the beam-splitter and their interference is imaged in the CCD. The new design is compact, vibration insensitive, and suitable for the measurement of moving objects or dynamic processes.

  11. Phase-shifting point diffraction interferometer grating designs

    DOEpatents

    Naulleau, Patrick; Goldberg, Kenneth Alan; Tejnil, Edita

    2001-01-01

    In a phase-shifting point diffraction interferometer, by sending the zeroth-order diffraction to the reference pinhole of the mask and the first-order diffraction to the test beam window of the mask, the test and reference beam intensities can be balanced and the fringe contrast improved. Additionally, using a duty cycle of the diffraction grating other than 50%, the fringe contrast can also be improved.

  12. 16 CFR Figure 5 to Subpart A of... - Zero Reference Point Related to Detecting Plane

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Zero Reference Point Related to Detecting Plane 5 Figure 5 to Subpart A of Part 1209 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard Pt. 1209, Subpt. A, Fig. 5 Figure 5 to Subpart A o...

  13. Reference Values for the Pediatric Quality of Life Inventory and the Multidimensional Fatigue Scale in Adolescent Athletes by Sport and Sex.

    PubMed

    Snyder Valier, Alison R; Welch Bacon, Cailee E; Bay, R Curtis; Molzen, Eileen; Lam, Kenneth C; Valovich McLeod, Tamara C

    2017-10-01

    Effective use of patient-rated outcome measures to facilitate optimal patient care requires an understanding of the reference values of these measures within the population of interest. Little is known about reference values for commonly used patient-rated outcome measures in adolescent athletes. To determine reference values for the Pediatric Quality of Life Inventory (PedsQL) and the Multidimensional Fatigue Scale (MFS) in adolescent athletes by sport and sex. Cross-sectional study; Level of evidence, 3. A convenience sample of interscholastic adolescent athletes from 9 sports was used. Participants completed the PedsQL and MFS during one testing session at the start of their sport season. Data were stratified by sport and sex. Dependent variables included the total PedsQL score and the 5 PedsQL subscale scores: physical functioning, psychosocial functioning, emotional functioning, social functioning, and school functioning. Dependent variables for the MFS included 3 subscale scores: general functioning, sleep functioning, and cognitive functioning. Summary statistics were reported for total and subscale scores by sport and sex. Among 3574 males and 1329 female adolescent athletes, the PedsQL scores (100 possible points) generally indicated high levels of health regardless of sport played. Mean PedsQL total and subscales scores ranged from 82.6 to 95.7 for males and 83.9 to 95.2 for females. Mean MFS subscale scores (100 possible points) ranged from 74.2 to 90.9 for males and 72.8 to 87.4 for females. Healthy male and female adolescent athletes reported relatively high levels of health on the PedsQL subscales and total scores regardless of sport; no mean scores were lower than 82.6 points for males or 83.9 points for females. On the MFS, males and females tended to report low effect of general and cognitive fatigue regardless of sport; mean scores were higher than 83.5 points for males and 83.8 points for females. Clinically, athletes who score below the reference values for their sport have poorer health status than average adolescent athletes participating in that sport. Scores below reference values may warrant consideration of early intervention or treatment.

  14. Futures for Schooling in Australia: Nationalisation, Privatisation or Unification? Occasional Paper No. 13.

    ERIC Educational Resources Information Center

    Connors, Lyndsay

    An analysis of Australia's two conflicting trends in school governance and their effectiveness in meeting two major educational challenges is the purpose of this paper. Nationalization, which refers to greater centralization and increased national regulation; and privatization, which refers to decentralization, deregulation, and increased local…

  15. Determination of Medical Task Times in an Emergency Center Setting

    DTIC Science & Technology

    1990-08-01

    supraclavicular central venous line, "Wound expl." signifies wound exploration, and "thoracostomy" refers to tube thoracostomy. The task time for chest...bore line is needed for aggressive fluid resuscitation, or whenever monitoring of central venous pressure as a reflection of available blood volume...of newly annexed city territory. Most ALS responses in the central city are made within 4 min of receipt of calls. There were 68,000 EMS transports

  16. Type T reference function suitability for low temperature applications

    NASA Astrophysics Data System (ADS)

    Dowell, D.

    2013-09-01

    Type T thermocouples are commonly used in industrial measurement applications due to their accuracy relative to other thermocouple types, low cost, and the ready availability of measurement equipment. Type T thermocouples are very effective when used in differential measurements, as there is no cold junction compensation necessary for the connections to the measurement equipment. Type T's published accuracy specifications result in its frequent use in low temperature applications. An examination of over 328 samples from a number of manufacturers has been completed for this investigation. Samples were compared to a Standard Platinum Resistance Thermometer (SPRT) at the LN2 boiling point along with four other standardized measurement points using a characterized ice point reference, low-thermal EMF scanner and an 8.5 digit multimeter, and the data compiled and analyzed. The test points were approximately -196 °C, -75 °C, 0 °C, +100 °C, and +200 °C. These data show an anomaly in the conformance to the reference functions where the reference functions meet at 0 °C. Additionally, in the temperature region between -100 °C to -200 °C, a positive offset of up to 5.4 °C exists between the reference function equations published in the ASTM E230-06 for the nitrogen point and the measured response of the actual wire. This paper will examine the historical and technological reasons for this anomaly in the both the ASTM and IEC reference functions. At the request of the author and the Proceedings Editor the above article has been replaced with a corrected version. The original PDF file supplied to AIP Publishing contained several figures with missing information/characters—caused by processes used to generate the PDF file. All figures were affected by this error. The article has been replaced and these figures now display correctly. The corrected article was published on 7 November 2013.

  17. 18. Detail view of central pivot pier, drive gear rack, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Detail view of central pivot pier, drive gear rack, and stabilizing wheel, looking southwest - India Point Railroad Bridge, Spanning Seekonk River between Providence & East Providence, Providence, Providence County, RI

  18. Morphing of spatial objects in real time with interpolation by functions of radial and orthogonal basis

    NASA Astrophysics Data System (ADS)

    Kosnikov, Yu N.; Kuzmin, A. V.; Ho, Hoang Thai

    2018-05-01

    The article is devoted to visualization of spatial objects’ morphing described by the set of unordered reference points. A two-stage model construction is proposed to change object’s form in real time. The first (preliminary) stage is interpolation of the object’s surface by radial basis functions. Initial reference points are replaced by new spatially ordered ones. Reference points’ coordinates change patterns during the process of morphing are assigned. The second (real time) stage is surface reconstruction by blending functions of orthogonal basis. Finite differences formulas are applied to increase the productivity of calculations.

  19. Discrepancy-based error estimates for Quasi-Monte Carlo III. Error distributions and central limits

    NASA Astrophysics Data System (ADS)

    Hoogland, Jiri; Kleiss, Ronald

    1997-04-01

    In Quasi-Monte Carlo integration, the integration error is believed to be generally smaller than in classical Monte Carlo with the same number of integration points. Using an appropriate definition of an ensemble of quasi-random point sets, we derive various results on the probability distribution of the integration error, which can be compared to the standard Central Limit Theorem for normal stochastic sampling. In many cases, a Gaussian error distribution is obtained.

  20. Implementation of a reference standard and proficiency testing programme by the World Wide Antimalarial Resistance Network (WWARN)

    PubMed Central

    2010-01-01

    Background The Worldwide Antimalarial Resistance Network (WWARN) is a global collaboration to support the objective that anyone affected by malaria receives effective and safe drug treatment. The Pharmacology module aims to inform optimal anti-malarial drug selection. There is an urgent need to define the drug exposure - effect relationship for most anti-malarial drugs. Few anti-malarials have had their therapeutic blood concentration levels defined. One of the main challenges in assessing safety and efficacy data in relation to drug concentrations is the comparability of data generated from different laboratories. To explain differences in anti-malarial pharmacokinetics in studies with different measurement laboratories it is necessary to confirm the accuracy of the assay methods. This requires the establishment of an external quality assurance process to assure results that can be compared. This paper describes this process. Methods The pharmacology module of WWARN has established a quality assurance/quality control (QA/QC) programme consisting of two separate components: 1. A proficiency testing programme where blank human plasma spiked with certified reference material (CRM) in different concentrations is sent out to participating bioanalytical laboratories. 2. A certified reference standard programme where accurately weighed amounts of certified anti-malarial reference standards, metabolites, and internal standards are sent to participating bioanalytical and in vitro laboratories. Conclusion The proficiency testing programme is designed as a cooperative effort to help participating laboratories assess their ability to carry out drug analysis, resolve any potential problem areas and to improve their results - and, in so doing, to improve the quality of anti-malarial pharmacokinetic data published and shared with WWARN. By utilizing the same source of standards for all laboratories, it is possible to minimize bias arising from poor quality reference standards. By providing anti-malarial drug standards from a central point, it is possible to lower the cost of these standards. PMID:21184684

  1. Influence of Preadjusted Bracket Shape and Positioning Reference on Angulation of Upper Central Incisor.

    PubMed

    Topolski, Francielle; de O Accorsi, Mauricio A; Trevisi, Hugo J; Cuoghi, Osmar A; Moresca, Ricardo

    2016-10-01

    To verify the influence of different bracket shapes and placement references according to Andrews and MBT systems on the expression of angulation in upper central incisors (UCI). Bracket positioning and mesiodistal dental movement simulations were performed and the angulations produced in the dental crown were evaluated, based on computed tomography scan images of 30 UCI and AutoCAD software analysis. Rectangular (Andrews) and rhomboid (MBT) brackets were placed according to the references recommended by Andrews and MBT systems - long axis of the clinical crown (LACC) and incisal edge (IE) respectively. Data showed that the use of LACC as reference for bracket positioning produced 5° and 4° UCI angulations in Andrews and MBT brackets respectively. The use of IE produced a 1.2° mean angulation in UCI for both brackets. When the LACC was used as reference for bracket positioning, the UCI crown angulation corresponded to the angulation built into the brackets, regardless of shape, while the use of IE resulted in natural crown angulation, regardless of bracket shape. This research contributes to guide the orthodontist in relation to the different treatment techniques based on the use of preadjusted brackets.

  2. Solar thermal power systems point-focusing thermal and electric applications projects. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    Marriott, A.

    1980-01-01

    The activities of the Point-Focusing Thermal and Electric Applications (PETEA) project for the fiscal year 1979 are summarized. The main thrust of the PFTEA Project, the small community solar thermal power experiment, was completed. Concept definition studies included a small central receiver approach, a point-focusing distributed receiver system with central power generation, and a point-focusing distributed receiver concept with distributed power generation. The first experiment in the Isolated Application Series was initiated. Planning for the third engineering experiment series, which addresses the industrial market sector, was also initiated. In addition to the experiment-related activities, several contracts to industry were let and studies were conducted to explore the market potential for point-focusing distributed receiver (PFDR) systems. System analysis studies were completed that looked at PFDR technology relative to other small power system technology candidates for the utility market sector.

  3. Proof of concept Laplacian estimate derived for noninvasive tripolar concentric ring electrode with incorporated radius of the central disc and the widths of the concentric rings.

    PubMed

    Makeyev, Oleksandr; Lee, Colin; Besio, Walter G

    2017-07-01

    Tripolar concentric ring electrodes are showing great promise in a range of applications including braincomputer interface and seizure onset detection due to their superiority to conventional disc electrodes, in particular, in accuracy of surface Laplacian estimation. Recently, we proposed a general approach to estimation of the Laplacian for an (n + 1)-polar electrode with n rings using the (4n + 1)-point method for n ≥ 2 that allows cancellation of all the truncation terms up to the order of 2n. This approach has been used to introduce novel multipolar and variable inter-ring distances concentric ring electrode configurations verified using finite element method. The obtained results suggest their potential to improve Laplacian estimation compared to currently used constant interring distances tripolar concentric ring electrodes. One of the main limitations of the proposed (4n + 1)-point method is that the radius of the central disc and the widths of the concentric rings are not included and therefore cannot be optimized. This study incorporates these two parameters by representing the central disc and both concentric rings as clusters of points with specific radius and widths respectively as opposed to the currently used single point and concentric circles. A proof of concept Laplacian estimate is derived for a tripolar concentric ring electrode with non-negligible radius of the central disc and non-negligible widths of the concentric rings clearly demonstrating how both of these parameters can be incorporated into the (4n + 1)-point method.

  4. Three questions you need to ask about your brand.

    PubMed

    Keller, Kevin Lane; Sternthal, Brian; Tybout, Alice

    2002-09-01

    Traditionally, the people responsible for positioning brands have concentrated on the differences that set each brand apart from the competition. But emphasizing differences isn't enough to sustain a brand against competitors. Managers should also consider the frame of reference within which the brand works and the features the brand shares with other products. Asking three questions about your brand can help: HAVE WE ESTABLISHED A FRAME?: A frame of reference--for Coke, it might be as narrow as other colas or as broad as all thirst-quenching drinks--signals to consumers the goal they can expect to achieve by using a brand. Brand managers need to pay close attention to this issue, in some cases expanding their focus in order to preempt the competition. ARE WE LEVERAGING OUR POINTS OF PARITY?: Certain points of parity must be met if consumers are to perceive your product as a legitimate player within its frame of reference. For instance, consumers might not consider a bank truly a bank unless it offers checking and savings plans. ARE THE POINTS OF DIFFERENCE COMPELLING?: A distinguishing characteristic that consumers find both relevant and believable can become a strong, favorable, unique brand association, capable of distinguishing the brand from others in the same frame of reference. Frames of reference, points of parity, and points of difference are moving targets. Maytag isn't the only dependable brand of appliance, Tide isn't the only detergent with whitening power, and BMWs aren't the only cars on the road with superior handling. The key questions you need to ask about your brand may not change, but their context certainly will. The saviest brand positioners are also the most vigilant.

  5. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  6. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  7. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  8. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  9. 7 CFR 1.626 - What regulations apply to a case referred for a hearing?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... referred for a hearing? (a) If NFS refers the case to OALJ, these regulations will continue to apply to the hearing process. (b) If NFS refers the case to the Department of the Interior's Office of Hearing and Appeals, the regulations at 43 CFR 45.1 et seq. will apply from that point. (c) If NFS refers the case to...

  10. Outdoor near-roadway, community and residential pollen, carbon dioxide and particulate matter measurements in the urban core of an agricultural region in central CA

    NASA Astrophysics Data System (ADS)

    Shendell, Derek G.; Therkorn, Jennifer H.; Yamamoto, Naomichi; Meng, Qingyu; Kelly, Sarah W.; Foster, Christine A.

    2012-04-01

    We can control asthma through proper clinical and environmental management and education. The U.S. population is growing, urbanizing and aging; seniors of low-to-middle income families are working and living longer. We conducted community-based participatory research in Visalia, Tulare County, California with a prospective, cross-sectional repeated measures design and quantitative and qualitative process; home environment and health-related outcomes data were collected. In this paper, we presented results of the air quality sampling-pollen, carbon dioxide (CO2) and particulate matter (PM) outdoors away from most major sources (agricultural fields, large pollinating trees, etc)-at a community central site close to a mobile line source and participant homes in the cooling season, July, 2009. Weather was hot and dry with light winds; diurnal variation ranged between 65-107 °F (18-42 °C) and 12-76% relative humidity at the study's central site. Co-located active (reference) and passive (PAAS) samplers were used for pollen; passive monitoring for CO2 (Telaire 7001) and active sampling for PM were conducted. Overall, we observed spatial variability in CO2, fine PM (PM2.5), and pollen counts. Weekday and study week average CO2 and PM2.5 concentrations were higher near study homes compared to central site sampling points, but peak measures and overnight/pre-dawn time period averages were elevated at the central site. Pollen counts were typically lower at homes-even if grass, trees, flowers or potted plants were present-compared to the central site closer to and generally downwind from commercial agricultural tree production. Data are new; the nine-county San Joaquin Valley has one pollen count station in the national network, and two of four government outdoor air monitoring stations in the county are in national parks. We suggest-given poor air quality in large part due to PM-adding routine pollen counts to regional/state agency air monitoring sites and more CO2 and PM monitoring.

  11. Influence of Monsoon variations on ecosystem changes on the Central Tibetan Plateau during the last 24 ka cal BP (Invited)

    NASA Astrophysics Data System (ADS)

    Kasper, T.; Haberzettl, T.; Zhu, L.; Maeusbacher, R.

    2013-12-01

    Lakes as archives of climate and environmental change are well known and well investigated all over the world, also in high mountain areas such as the Tibetan Plateau (TP) which is one of the most important key players in global climate circulation. Lake sediment records in this area, which were subject to lots of paleoenvironmental investigations, are mostly focused on the Holocene, often showing discontinuities due to desiccation or are located at the margin of the TP, such as Lake Qinghai. Here we present the first continuous lake sediment record from the southern central TP from Lake Nam Co, comprising ~24 ka cal BP, i.e., the LGM, the post-Glacial and the entire Holocene. The record reveals environmental changes with varying intensities. Extraordinary high sediment accumulation rates (SAR = 1.3 mm a-1) and quite large quantities of minerogenic input associated with the absence of ostracods during the LGM point to a small lake within a cold and dry environment. Around 19 ka cal BP reduced SAR (~0.3 mm a-1) and the occurrence of ostracods refer to a rising lake level in a moister environment. During the post-Glacial (~16 ka cal BP) changes in the geochemical composition of the sediments and a shift in the pollen composition suggests a change in summer precipitation and wind direction associated with a stronger Indian Ocean Summer Monsoon (IOSM). Major variations in the geochemical parameters between ~12.6 and ~11.6 ka cal BP may reflect the Younger Dryas climate oscillation of the Northern Hemisphere with cool and arid environmental conditions. The most striking hydrological variation within this record occurs at ~9.5 ka cal BP in the early Holocene. A rise in TOC points to enhanced bio-productivity within the lake and the catchment as well as to hampered decomposition of organic matter at the lake floor. Pollen composition refers to alpine meadow vegetation assemblages during this time. This may reflect moist and warm conditions probably associated with a higher lake level and a strong stratification of the water body. Nevertheless, during the mid- and late-Holocene some changes of minor amplitude also occur. Around 4 ka cal BP a short-term increase in Mg points to a dry-event as seen in other monsoon dominated records. The probably most intensive shift to drier conditions with a rapidly falling lake level has been proposed to have occurred around 2 ka cal BP. Even the recent climate warming associated with higher rates of glacier melting, enhanced surface runoff and a rising lake level is reflected by this multi-proxy investigation.

  12. Application of point-to-point matching algorithms for background correction in on-line liquid chromatography-Fourier transform infrared spectrometry (LC-FTIR).

    PubMed

    Kuligowski, J; Quintás, G; Garrigues, S; de la Guardia, M

    2010-03-15

    A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08%, v/v TFA):water (0.08%, v/v TFA) gradients with compositions ranging from 35 to 85% (v/v) acetonitrile, giving accurate results for both, baseline resolved and overlapped peaks. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  13. Three-dimensional stereophotogrammetric analysis of 50 smiles: A study of dento-facial proportions.

    PubMed

    Ceinos, R; Lupi, L; Tellier, A; Bertrand, M F

    2017-11-12

    The purpose of this study was to analyze 50 smiles using 3D stereophotogrammetry (3D-spg)-based facial reconstruction, to calculate ratios involving measurements of the distances between dental and facial landmarks and to compare these ratios with the golden ratio φ (1.618). Fifty subjects with no obvious malocclusion participated in this study. For each subject, 4 photographs were acquired using the LifeViz Mini™, an absolute calibration 3D-spg system. Facial and dental landmarks (based on Farkas' definitions) were fixed, and 8 distances were measured. Four ratios were then calculated and compared with the value of 1.618. The ratio "incisal edge of the maxillary central incisor-lower border of the chin/subnasal point-incisal edge of the maxillary central incisor" (IE-Me/SN-IE) was 1.693 ± 0.190, the ratio "right endocanthion-left endocanthion/right exocanthion-right endocanthion" was 1.582 ± 0.173, the ratio "incisal edge of the maxillary central incisor-distal edge of the right canine/distal edge of the right canine-right labial commissure" was 1.670 ± 0.355, and the ratio "right labial commissure-left labial commissure/distal edge of the right canine-distal edge of the left canine" was 1.602 ± 0.136. In contrast, the vertical ratio IE-Me/SN-IE significantly differed from the golden ratio (1 sample t test, P = .009). This study revealed that the observed ratios were surprisingly close to the golden ratio. Only the vertical ratio differed from the golden ratio, whereas the horizontal ratios appear to be adequately approximated by φ. If the distances from reference points of the face to teeth within a harmonious smile exhibited recurring esthetic proportions, knowledge of such ratios would provide an additional tool for the elaboration of esthetic treatment plans. In addition, this knowledge could provide guidance when planning tooth positions and dental proportions by encouraging consideration of the global nature of the oro-facial sphere. © 2017 Wiley Periodicals, Inc.

  14. Assessment of the sustainability of dual-purpose farms by the IDEA method in the subtropical area of central Mexico.

    PubMed

    Salas-Reyes, Isela Guadalupe; Arriaga-Jordán, Carlos Manuel; Rebollar-Rebollar, Samuel; García-Martínez, Anastacio; Albarrán-Portillo, Benito

    2015-08-01

    The objective of this study was to assess the sustainability of 10 dual-purpose cattle farms in a subtropical area of central Mexico. The IDEA method (Indicateurs de Durabilité des Exploitations Agricoles) was applied, which includes the agroecological, socio-territorial and economic scales (scores from 0 to 100 points per scale). A sample of 47 farms from a total of 91 registered in the local livestock growers association was analysed with principal component analysis and cluster analysis. From results, 10 farms were selected for the in-depth study herein reported, being the selection criterion continuous milk production throughout the year. Farms had a score of 88 and 86 points for the agroecological scale in the rainy and dry seasons. In the socio-territorial scale, scores were 73 points for both seasons, being the component of employment and services the strongest. Scores for the economic scale were 64 and 56 points for the rainy and dry seasons, respectively, when no economic cost for family labour is charged, which decreases to 59 and 45 points when an opportunity cost for family labour is considered. Dual-purpose farms in the subtropical area of central Mexico have a medium sustainability, with the economic scale being the limiting factor, and an area of opportunity.

  15. Norepinephrine transporter blocker atomoxetine increases salivary alpha amylase.

    PubMed

    Warren, Christopher M; van den Brink, Ruud L; Nieuwenhuis, Sander; Bosch, Jos A

    2017-04-01

    It has been suggested that central norepinephrine (NE) activity may be inferred from increases in salivary alpha-amylase (SAA), but data in favor of this proposition are limited. We administered 40mg of atomoxetine, a selective NE transporter blocker that increases central NE levels, to 24 healthy adult participants in a double-blind, placebo-controlled cross-over design. Atomoxetine administration significantly increased SAA secretion and concentrations at 75-180min after treatment (more than doubling baseline levels). Consistent with evidence that elevation in central NE is a co-determinant of hypothalamic-pituitary-adrenal axis activity, salivary cortisol also approximately doubled at the same time points. Moreover, changes in salivary cortisol positively correlated with SAA (0.44

  16. CT-image-based conformal brachytherapy of breast cancer. The significance of semi-3-D and 3-D treatment planning.

    PubMed

    Polgár, C; Major, T; Somogyi, A; Takácsi-Nagy, Z; Mangel, L C; Forrai, G; Sulyok, Z; Fodor, J; Németh, G

    2000-03-01

    To compare the conventional 2-D, the simulator-guided semi-3-D and the recently developed CT-guided 3-D brachytherapy treatment planning in the interstitial radiotherapy of breast cancer. In 103 patients with T1-2, N0-1 breast cancer the tumor bed was clipped during breast conserving surgery. Fifty-two of them received boost brachytherapy after 46 to 50 Gy teletherapy and 51 patients were treated with brachytherapy alone via flexible implant tubes. Single, double and triple plane implant was used in 6, 89 and 8 cases, respectively. The dose of boost brachytherapy and sole brachytherapy prescribed to dose reference points was 3 times 4.75 Gy and 7 times 5.2 Gy, respectively. The positions of dose reference points varied according to the level (2-D, semi-3-D and 3-D) of treatment planning performed. The treatment planning was based on the 3-D reconstruction of the surgical clips, implant tubes and skin points. In all cases the implantations were planned with a semi-3-D technique aided by simulator. In 10 cases a recently developed CT-guided 3-D planning system was used. The semi-3-D and 3-D treatment plans were compared to hypothetical 2-D plans using dose-volume histograms and dose non-uniformity ratios. The values of mean central dose, mean skin dose, minimal clip dose, proportion of underdosaged clips and mean target surface dose were evaluated. The accuracy of tumor bed localization and the conformity of planning target volume and treated volume were also analyzed in each technique. With the help of conformal semi-3-D and 3-D brachytherapy planning we could define reference dose points, active source positions and dwell times individually. This technique decreased the mean skin dose with 22.2% and reduced the possibility of geographical miss. We could achieve the best conformity between the planning target volume and the treated volume with the CT-image based 3-D treatment planning, at the cost of worse dose homogeneity. The mean treated volume was reduced by 25.1% with semi-3-D planning, however, it was increased by 16.2% with 3-D planning, compared to the 2-D planning. The application of clips into the tumor bed and the conformal (semi-3-D and 3-D) planning help to avoid geographical miss. CT is suitable for 3-D brachytherapy planning. Better local control with less side effects might be achieved with these new techniques. Conformal 3-D brachytherapy calls for new treatment planning concepts, taking the irregular 3-D shape of the target volume into account. The routine clinical application of image-based 3-D brachytherapy is a real aim in the very close future.

  17. Trigger point-related sympathetic nerve activity in chronic sciatic leg pain: a case study.

    PubMed

    Skorupska, Elżbieta; Rychlik, Michał; Pawelec, Wiktoria; Bednarek, Agata; Samborski, Włodzimierz

    2014-10-01

    Sciatica has classically been associated with irritation of the sciatic nerve by the vertebral disc and consequent inflammation. Some authors suggest that active trigger points in the gluteus minimus muscle can refer pain in similar way to sciatica. Trigger point diagnosis is based on Travel and Simons criteria, but referred pain and twitch response are significant confirmatory signs of the diagnostic criteria. Although vasoconstriction in the area of a latent trigger point has been demonstrated, the vasomotor reaction of active trigger points has not been examined. We report the case of a 22-year-old Caucasian European man who presented with a 3-year history of chronic sciatic-type leg pain. In the third year of symptoms, coexistent myofascial pain syndrome was diagnosed. Acupuncture needle stimulation of active trigger points under infrared thermovisual camera showed a sudden short-term vasodilatation (an autonomic phenomenon) in the area of referred pain. The vasodilatation spread from 0.2 to 171.9 cm(2) and then gradually decreased. After needling, increases in average and maximum skin temperature were seen as follows: for the thigh, changes were +2.6°C (average) and +3.6°C (maximum); for the calf, changes were +0.9°C (average) and +1.4°C (maximum). It is not yet known whether the vasodilatation observed was evoked exclusively by dry needling of active trigger points. The complex condition of the patient suggests that other variables might have influenced the infrared thermovision camera results. We suggest that it is important to check if vasodilatation in the area of referred pain occurs in all patients with active trigger points. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  18. Point to a Referent, and Say, "What Is This?" Gesture as a Potential Cue to Identify Referents in a Discourse

    ERIC Educational Resources Information Center

    So, Wing Chee; Lim, Jia Yi

    2012-01-01

    This study explored whether caregivers' gestures followed the discourse-pragmatic principle of information status of referents (given vs. new) and how their children responded to those gestures when identifying referents. Ten Chinese-speaking and eight English-speaking caregivers were videotaped while interacting spontaneously with their children.…

  19. Impact of Santiago de Chile urban atmospheric pollution on anthropogenic trace elements enrichment in snow precipitation at Cerro Colorado, Central Andes

    NASA Astrophysics Data System (ADS)

    Cereceda-Balic, F.; Palomo-Marín, M. R.; Bernalte, E.; Vidal, V.; Christie, J.; Fadic, X.; Guevara, J. L.; Miro, C.; Pinilla Gil, E.

    2012-02-01

    Seasonal snow precipitation in the Andes mountain range is evaluated as an environmental indicator of the composition of atmospheric emissions in Santiago de Chile metropolitan area, by measuring a set of representative trace elements in snow samples by ICP-MS. Three late winter sampling campaigns (2003, 2008 and 2009) were conducted in three sampling areas around Cerro Colorado, a Central Andes mountain range sector NE of Santiago (36 km). Nevados de Chillán, a sector in The Andes located about 500 km south from the metropolitan area, was selected as a reference area. The experimental results at Cerro Colorado and Nevados de Chillán were compared with previously published data of fresh snow from remote and urban background sites. High snow concentrations of a range of anthropogenic marker elements were found at Cerro Colorado, probably derived from Santiago urban aerosol transport and deposition combined with the effect of mining and smelting activities in the area, whereas Nevados de Chillán levels roughly correspond to urban background areas. Enhanced concentrations in surface snow respect to deeper samples are discussed. Significant differences found between the 2003, 2008 and 2009 anthropogenic source markers profiles at Cerro Colorado sampling points were correlated with changes in emission sources at the city. The preliminary results obtained in this study, the first of this kind in the southern hemisphere, show promising use of snow precipitation in the Central Andes as a suitable matrix for receptor model studies aimed at identifying and quantifying pollution sources in Santiago de Chile.

  20. Introduction to selected references on fossil fuels of the central and southern Appalachian basin: Chapter H.1 in Coal and petroleum resources in the Appalachian basin: distribution, geologic framework, and geochemical character

    USGS Publications Warehouse

    Ruppert, Leslie F.; Lentz, Erika E.; Tewalt, Susan J.; Román Colón, Yomayra A.; Ruppert, Leslie F.; Ryder, Robert T.

    2014-01-01

    The Appalachian basin contains abundant coal and petroleum resources that have been studied and extracted for at least 150 years. In this volume, U.S. Geological Survey (USGS) scientists describe the geologic framework and geochemical character of the fossil-fuel resources of the central and southern Appalachian basin. Separate subchapters (some previously published) contain geologic cross sections; seismic profiles; burial history models; assessments of Carboniferous coalbed methane and Devonian shale gas; distribution information for oil, gas, and coal fields; data on the geochemistry of natural gas and oil; and the fossil-fuel production history of the basin. Although each chapter and subchapter includes references cited, many historical or other important references on Appalachian basin and global fossil-fuel science were omitted because they were not directly applicable to the chapters.

  1. The Weak Coherence Account: Detail-Focused Cognitive Style in Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Happe, Francesca; Frith, Uta

    2006-01-01

    "Weak central coherence" refers to the detail-focused processing style proposed to characterise autism spectrum disorders (ASD). The original suggestion of a core deficit in central processing resulting in failure to extract global form/meaning, has been challenged in three ways. First, it may represent an outcome of superiority in local…

  2. Metaphors--Messengers of Meaning: A Contribution to an Evolutionary Sociology of Science.

    ERIC Educational Resources Information Center

    Maasen, Sabine; Weingart, Peter

    1995-01-01

    Presents the idea that the central link between science and society is established by a diffusion of knowledge. Suggests knowledge transfers may be analyzed in a metaphorical context and that a metaphorical analysis should be combined with discourse analysis and central concepts of evolutionary theory. (50 references) (Author/AEF)

  3. Research publications of the Pringle Falls Experimental Forest, central Oregon Cascade Range, 1930 to 1993.

    Treesearch

    A. Youngblood

    1995-01-01

    An annotated bibliography of publications resulting from research at the Pringle Falls Experimental Forest, Deschutes National Forest, in central Oregon from 1930 to 1993 is presented. Over 100 publications are listed, including papers, theses, and reports. An index is provided that cross-references the listings under appropriate keywords.

  4. Diagnostic Challenges of Central Nervous System Tuberculosis

    PubMed Central

    Loeffler, Ann M.; Honarmand, Somayeh; Flood, Jennifer M.; Baxter, Roger; Jacobson, Susan; Alexander, Rick; Glaser, Carol A.

    2008-01-01

    Central nervous system tuberculosis (TB) was identified in 20 cases of unexplained encephalitis referred to the California Encephalitis Project. Atypical features (encephalitic symptoms, rapid onset, age) and diagnostic challenges (insensitive cerebrospinal fluid [CSF] TB PCR result, elevated CSF glucose levels in patients with diabetes, negative result for tuberculin skin test) complicated diagnosis. PMID:18760024

  5. INTERIOR FROM WESTERN SECTION, THROUGH CENTRAL SECTION, TO EASTERN SECTION, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR FROM WESTERN SECTION, THROUGH CENTRAL SECTION, TO EASTERN SECTION, VIEW FACING NORTHEAST. - Naval Air Station Barbers Point, Aircraft Storehouse, Between Midway & Card Streets at Enterprise Avenue intersection, Ewa, Honolulu County, HI

  6. Nursing Reference Center: a point-of-care resource.

    PubMed

    Vardell, Emily; Paulaitis, Gediminas Geddy

    2012-01-01

    Nursing Reference Center is a point-of-care resource designed for the practicing nurse, as well as nursing administrators, nursing faculty, and librarians. Users can search across multiple resources, including topical Quick Lessons, evidence-based care sheets, patient education materials, practice guidelines, and more. Additional features include continuing education modules, e-books, and a new iPhone application. A sample search and comparison with similar databases were conducted.

  7. Reliable landmarks for precise topographical analyses of pathological structural changes of the ovine tibial plateau in 2-D and 3-D subspaces.

    PubMed

    Oláh, Tamás; Reinhard, Jan; Gao, Liang; Goebel, Lars K H; Madry, Henning

    2018-01-08

    Selecting identical topographical locations to analyse pathological structural changes of the osteochondral unit in translational models remains difficult. The specific aim of the study was to provide objectively defined reference points on the ovine tibial plateau based on 2-D sections of micro-CT images useful for reproducible sample harvesting and as standardized landmarks for landmark-based 3-D image registration. We propose 5 reference points, 11 reference lines and 12 subregions that are detectable macroscopically and on 2-D micro-CT sections. Their value was confirmed applying landmark-based rigid and affine 3-D registration methods. Intra- and interobserver comparison showed high reliabilities, and constant positions (standard errors < 1%). Spatial patterns of the thicknesses of the articular cartilage and subchondral bone plate were revealed by measurements in 96 individual points of the tibial plateau. As a case study, pathological phenomena 6 months following OA induction in vivo such as osteophytes and areas of OA development were mapped to the individual subregions. These new reference points and subregions are directly identifiable on tibial plateau specimens or macroscopic images, enabling a precise topographical location of pathological structural changes of the osteochondral unit in both 2-D and 3-D subspaces in a region-appropriate fashion relevant for translational investigations.

  8. An aggregate method to calibrate the reference point of cumulative prospect theory-based route choice model for urban transit network

    NASA Astrophysics Data System (ADS)

    Zhang, Yufeng; Long, Man; Luo, Sida; Bao, Yu; Shen, Hanxia

    2015-12-01

    Transit route choice model is the key technology of public transit systems planning and management. Traditional route choice models are mostly based on expected utility theory which has an evident shortcoming that it cannot accurately portray travelers' subjective route choice behavior for their risk preferences are not taken into consideration. Cumulative prospect theory (CPT), a brand new theory, can be used to describe travelers' decision-making process under the condition of uncertainty of transit supply and risk preferences of multi-type travelers. The method to calibrate the reference point, a key parameter to CPT-based transit route choice model, determines the precision of the model to a great extent. In this paper, a new method is put forward to obtain the value of reference point which combines theoretical calculation and field investigation results. Comparing the proposed method with traditional method, it shows that the new method can promote the quality of CPT-based model by improving the accuracy in simulating travelers' route choice behaviors based on transit trip investigation from Nanjing City, China. The proposed method is of great significance to logical transit planning and management, and to some extent makes up the defect that obtaining the reference point is solely based on qualitative analysis.

  9. Endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization.

    PubMed

    Pikwer, Andreas; Acosta, Stefan; Kölbel, Tilo; Åkeson, Jonas

    2010-01-01

    This study was designed to assess endovascular intervention for central venous cannulation in patients with vascular occlusion after previous catheterization. Patients referred for endovascular management of central venous occlusion during a 42-month period were identified from a regional endovascular database, providing prospective information on techniques and clinical outcome. Corresponding patient records, angiograms, and radiographic reports were analyzed retrospectively. Sixteen patients aged 48 years (range 0.5-76), including 11 females, were included. All patients but 1 had had multiple central venous catheters with a median total indwelling time of 37 months. Eleven patients cannulated for hemodialysis had had significantly fewer individual catheters inserted compared with 5 patients cannulated for nutritional support (mean 3.6 vs. 10.2, p<0.001) before endovascular intervention. Preoperative imaging by magnetic resonance tomography (MRT) in 8 patients, computed tomography (CT) venography in 3, conventional angiography in 6, and/or ultrasonography in 8, verified 15 brachiocephalic, 13 internal jugular, 3 superior caval, and/or 3 subclavian venous occlusions. Patients were subjected to recanalization (n=2), recanalization and percutaneous transluminal angioplasty (n=5), or stenting for vena cava superior syndrome (n=1) prior to catheter insertion. The remaining 8 patients were cannulated by avoiding the occluded route. Central venous occlusion occurs particularly in patients under hemodialysis and with a history of multiple central venous catheterizations with large-diameter catheters and/or long total indwelling time periods. Patients with central venous occlusion verified by CT or MRT venography and need for central venous access should be referred for endovascular intervention.

  10. Experimental Evaluation of a Deformable Registration Algorithm for Motion Correction in PET-CT Guided Biopsy.

    PubMed

    Khare, Rahul; Sala, Guillaume; Kinahan, Paul; Esposito, Giuseppe; Banovac, Filip; Cleary, Kevin; Enquobahrie, Andinet

    2013-01-01

    Positron emission tomography computed tomography (PET-CT) images are increasingly being used for guidance during percutaneous biopsy. However, due to the physics of image acquisition, PET-CT images are susceptible to problems due to respiratory and cardiac motion, leading to inaccurate tumor localization, shape distortion, and attenuation correction. To address these problems, we present a method for motion correction that relies on respiratory gated CT images aligned using a deformable registration algorithm. In this work, we use two deformable registration algorithms and two optimization approaches for registering the CT images obtained over the respiratory cycle. The two algorithms are the BSpline and the symmetric forces Demons registration. In the first optmization approach, CT images at each time point are registered to a single reference time point. In the second approach, deformation maps are obtained to align each CT time point with its adjacent time point. These deformations are then composed to find the deformation with respect to a reference time point. We evaluate these two algorithms and optimization approaches using respiratory gated CT images obtained from 7 patients. Our results show that overall the BSpline registration algorithm with the reference optimization approach gives the best results.

  11. Moving objects with clumsy fingers: how predictive is grip force control in patients with impaired manual sensibility?

    PubMed

    Nowak, Dennis A; Hermsdörfer, Joachim; Marquardt, Christian; Topka, Helge

    2003-03-01

    Anticipatory grip force adjustments to movement-induced load fluctuations of a hand-held object suggest that motion planning is based on an internal forward model of both the external object properties and the dynamics of the own motor apparatus. However, the central nervous system also refers to real time sensory feedback from the grasping digits in order to achieve a highly economical coupling between grip force and the actual loading requirements. We analyzed grip force control during vertical point-to-point arm movements with a hand-held instrumented object in 9 patients with moderately impaired tactile sensibility of the grasping digits due to chronic median nerve compression (n = 3), axonal (n = 3) and demyelinating sensory polyneuropathy (n = 3) in comparison to 9 healthy age- and sex-matched control subjects. Point-to-point arm movements started and ended with the object being held stationary at rest. Load force changes arose from inertial loads related to the movement. A maximum of load force occurred early in upward and near the end of downward movements. Compared to healthy controls, patients with impaired manual sensibility generated similar static grip forces during stationary holding of the object and similar force ratios between maximum grip and load force. These findings reflect effective grip force scaling in relation to the movement-induced loads despite reduced afferent feedback from the grasping digits. For both groups the maxima of grip and load force coincided very closely in time, indicating that the temporal regulation of the grip force profile with the load profile was processed with a similar high precision. In addition, linear regression analyses between grip and load forces during movement-related load increase and load decrease phases revealed a similar precise temporo-spatial coupling between grip and load forces for patients and controls. Our results suggest that the precise and anticipatory adjustment of the grip force profile to the load force profile arising from voluntary arm movements with a hand-held object is centrally mediated and less under sensory feedback control. As suggested by previous investigations, the efficient scaling of the grip force magnitude in relation to the movement-induced loads may be intact when deficits of tactile sensibility from the grasping fingers are moderate.

  12. Datum maintenance of the main Egyptian geodetic control networks by utilizing Precise Point Positioning "PPP" technique

    NASA Astrophysics Data System (ADS)

    Rabah, Mostafa; Elmewafey, Mahmoud; Farahan, Magda H.

    2016-06-01

    A geodetic control network is the wire-frame or the skeleton on which continuous and consistent mapping, Geographic Information Systems (GIS), and surveys are based. Traditionally, geodetic control points are established as permanent physical monuments placed in the ground and precisely marked, located, and documented. With the development of satellite surveying methods and their availability and high degree of accuracy, a geodetic control network could be established by using GNSS and referred to an international terrestrial reference frame used as a three-dimensional geocentric reference system for a country. Based on this concept, in 1992, the Egypt Survey Authority (ESA) established two networks, namely High Accuracy Reference Network (HARN) and the National Agricultural Cadastral Network (NACN). To transfer the International Terrestrial Reference Frame to the HARN, the HARN was connected with four IGS stations. The processing results were 1:10,000,000 (Order A) for HARN and 1:1,000,000 (Order B) for NACN relative network accuracy standard between stations defined in ITRF1994 Epoch1996. Since 1996, ESA did not perform any updating or maintaining works for these networks. To see how non-performing maintenance degrading the values of the HARN and NACN, the available HARN and NACN stations in the Nile Delta were observed. The Processing of the tested part was done by CSRS-PPP Service based on utilizing Precise Point Positioning "PPP" and Trimble Business Center "TBC". The study shows the feasibility of Precise Point Positioning in updating the absolute positioning of the HARN network and its role in updating the reference frame (ITRF). The study also confirmed the necessity of the absent role of datum maintenance of Egypt networks.

  13. Comparing Theories of Reference-Dependent Choice

    ERIC Educational Resources Information Center

    Bhatia, Sudeep

    2017-01-01

    Preferences are influenced by the presence or absence of salient choice options, known as reference points. This behavioral tendency is traditionally attributed to the loss aversion and diminishing sensitivity assumptions of prospect theory. In contrast, some psychological research suggests that reference dependence is caused by attentional biases…

  14. Urban Mass Transportation.

    ERIC Educational Resources Information Center

    Mervine, K. E.

    This bibliography is part of a series of Environmental Resource Packets prepared under a grant from EXXON Education Foundation. The most authoritative and accessible references in the urban transportation field are reviewed. The authors, publisher, point of view, level, and summary are given for each reference. The references are categorized…

  15. 27 CFR 9.75 - Central Coast.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Mountain, California, scale 1:24,000, dated 1956, Photorevised 1980; (31) Half Moon Bay, California, scale..., Año Nuevo, Franklin Point, Pigeon Point, San Gregorio, Half Moon Bay, Montara Mountain and San...

  16. 27 CFR 9.75 - Central Coast.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Mountain, California, scale 1:24,000, dated 1956, Photorevised 1980; (31) Half Moon Bay, California, scale..., Año Nuevo, Franklin Point, Pigeon Point, San Gregorio, Half Moon Bay, Montara Mountain and San...

  17. 27 CFR 9.75 - Central Coast.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Mountain, California, scale 1:24,000, dated 1956, Photorevised 1980; (31) Half Moon Bay, California, scale..., Año Nuevo, Franklin Point, Pigeon Point, San Gregorio, Half Moon Bay, Montara Mountain and San...

  18. CDL description of the CDC 6600 stunt box

    NASA Technical Reports Server (NTRS)

    Hertzog, J. B.

    1971-01-01

    The CDC 6600 central memory control (stunt box) is described utilizing CDL (Computer Design Language), block diagrams, and text. The stunt box is a clearing house for all central memory references from the 6600 central and peripheral processors. Since memory requests can be issued simultaneously, the stunt box must be capable of assigning priorities to requests, of labeling requests so that the data will be distributed correctly, and of remembering rejected addresses due to memory conflicts.

  19. Integration of imagery and cartographic data through a common map base

    NASA Technical Reports Server (NTRS)

    Clark, J.

    1983-01-01

    Several disparate data types are integrated by using control points as the basis for spatially registering the data to a map base. The data are reprojected to match the coordinates of the reference UTM (Universal Transverse Mercator) map projection, as expressed in lines and samples. Control point selection is the most critical aspect of integrating the Thematic Mapper Simulator MSS imagery with the cartographic data. It is noted that control points chosen from the imagery are subject to error from mislocated points, either points that did not correlate well to the reference map or minor pixel offsets because of interactive cursorring errors. Errors are also introduced in map control points when points are improperly located and digitized, leading to inaccurate latitude and longitude coordinates. Nonsystematic aircraft platform variations, such as yawl, pitch, and roll, affect the spatial fidelity of the imagery in comparison with the quadrangles. Features in adjacent flight paths do not always correspond properly owing to the systematic panorama effect and alteration of flightline direction, as well as platform variations.

  20. 43 CFR 10005.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... amended (42 U.S.C. 4321 et seq.); and the Endangered Species Act of 1973, as amended (16 U.S.C. 1531 et... CONSERVATION PLAN § 10005.2 Definitions. The Act refers to the Central Utah Project Completion Act, Titles II... Conservation Commission, as established by section 301 of the Act. Interested parties refers to Federal and...

  1. 43 CFR 10005.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... amended (42 U.S.C. 4321 et seq.); and the Endangered Species Act of 1973, as amended (16 U.S.C. 1531 et... CONSERVATION PLAN § 10005.2 Definitions. The Act refers to the Central Utah Project Completion Act, Titles II... Conservation Commission, as established by section 301 of the Act. Interested parties refers to Federal and...

  2. 43 CFR 10005.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... amended (42 U.S.C. 4321 et seq.); and the Endangered Species Act of 1973, as amended (16 U.S.C. 1531 et... CONSERVATION PLAN § 10005.2 Definitions. The Act refers to the Central Utah Project Completion Act, Titles II... Conservation Commission, as established by section 301 of the Act. Interested parties refers to Federal and...

  3. 43 CFR 10005.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... amended (42 U.S.C. 4321 et seq.); and the Endangered Species Act of 1973, as amended (16 U.S.C. 1531 et... CONSERVATION PLAN § 10005.2 Definitions. The Act refers to the Central Utah Project Completion Act, Titles II... Conservation Commission, as established by section 301 of the Act. Interested parties refers to Federal and...

  4. Team Approach to Staffing the Reference Center: A Speculation.

    ERIC Educational Resources Information Center

    Lawson, Mollie D.; And Others

    This document applies theories of participatory management to a proposal for a model that uses a team approach to staffing university library reference centers. In particular, the Ward Edwards Library at Central Missouri State University is examined in terms of the advantages and disadvantages of its current approach. Special attention is given to…

  5. Ask Here PA: Large-Scale Synchronous Virtual Reference for Pennsylvania

    ERIC Educational Resources Information Center

    Mariner, Vince

    2008-01-01

    Ask Here PA is Pennsylvania's new statewide live chat reference and information service. This article discusses the key strategies utilized by Ask Here PA administrators to recruit participating libraries to contribute staff time to the service, the importance of centralized staff training, the main aspects of staff training, and activating the…

  6. Children's Spirituality with Particular Reference to a Norwegian Context: Some Hermeneutical Reflections

    ERIC Educational Resources Information Center

    Sagberg, Sturla

    2008-01-01

    Spirituality has become an issue in many domains of the Norwegian society, but this is not reflected in public education. This paper discusses why this is so, and suggests some hermeneutical approaches to understanding spirituality that can include pre-school children's spirituality, with particular reference to a Norwegian context. Central to…

  7. Untreated ADHD in Adults: Are There Sex Differences in Symptoms, Comorbidity, and Impairment?

    ERIC Educational Resources Information Center

    Rasmussen, Kirsten; Levander, Sten

    2009-01-01

    Objective: To analyze sex differences among adult, never-treated patients referred for central stimulant treatment of ADHD. Method: Data for 600 consecutive patients from northern Norway referred for evaluation by an expert team during 7 years were analyzed. General background information, diagnostic and social history, and symptom profiles were…

  8. Recommended reference genes for quantitative PCR analysis in soybean have variable stabilities during diverse biotic stresses

    USDA-ARS?s Scientific Manuscript database

    For real-time reverse transcription-PCR (qRT-PCR) in soybean, reference genes in different tissues, developmental stages, various cultivars, and under stress conditions have been suggested but their usefulness for research on soybean under various biotic stresses occurring in North-Central U.S. is n...

  9. Rapid Categorization of Foveal and Extrafoveal Natural Images: Associated ERPs and Effects of Lateralization

    ERIC Educational Resources Information Center

    Fize, Denis; Fabre-Thorpe, Michele; Richard, Ghislaine; Doyon, Bernard; Thorpe, Simon J.

    2005-01-01

    Humans are fast and accurate at performing an animal categorization task with natural photographs briefly flashed centrally. Here, this central categorization task is compared to a three position task in which photographs could appear randomly either centrally, or at 3.6 [degrees] eccentricity (right or left) of the fixation point. A mild…

  10. Central Configurations of the Curved N-Body Problem

    NASA Astrophysics Data System (ADS)

    Diacu, Florin; Stoica, Cristina; Zhu, Shuqiang

    2018-06-01

    We consider the N-body problem of celestial mechanics in spaces of nonzero constant curvature. Using the concept of effective potential, we define the moment of inertia for systems moving on spheres and hyperbolic spheres and show that we can recover the classical definition in the Euclidean case. After proving some criteria for the existence of relative equilibria, we find a natural way to define the concept of central configuration in curved spaces using the moment of inertia and show that our definition is formally similar to the one that governs the classical problem. We prove that, for any given point masses on spheres and hyperbolic spheres, central configurations always exist. We end with results concerning the number of central configurations that lie on the same geodesic, thus extending the celebrated theorem of Moulton to hyperbolic spheres and pointing out that it has no straightforward generalization to spheres, where the count gets complicated even for two bodies.

  11. A new scoring method for evaluating the performance of earthquake forecasts and predictions

    NASA Astrophysics Data System (ADS)

    Zhuang, J.

    2009-12-01

    This study presents a new method, namely the gambling score, for scoring the performance of earthquake forecasts or predictions. Unlike most other scoring procedures that require a regular scheme of forecast and treat each earthquake equally, regardless their magnitude, this new scoring method compensates the risk that the forecaster has taken. A fair scoring scheme should reward the success in a way that is compatible with the risk taken. Suppose that we have the reference model, usually the Poisson model for usual cases or Omori-Utsu formula for the case of forecasting aftershocks, which gives probability p0 that at least 1 event occurs in a given space-time-magnitude window. The forecaster, similar to a gambler, who starts with a certain number of reputation points, bets 1 reputation point on ``Yes'' or ``No'' according to his forecast, or bets nothing if he performs a NA-prediction. If the forecaster bets 1 reputation point of his reputations on ``Yes" and loses, the number of his reputation points is reduced by 1; if his forecasts is successful, he should be rewarded (1-p0)/p0 reputation points. The quantity (1-p0)/p0 is the return (reward/bet) ratio for bets on ``Yes''. In this way, if the reference model is correct, the expected return that he gains from this bet is 0. This rule also applies to probability forecasts. Suppose that p is the occurrence probability of an earthquake given by the forecaster. We can regard the forecaster as splitting 1 reputation point by betting p on ``Yes'' and 1-p on ``No''. In this way, the forecaster's expected pay-off based on the reference model is still 0. From the viewpoints of both the reference model and the forecaster, the rule for rewarding and punishment is fair. This method is also extended to the continuous case of point process models, where the reputation points bet by the forecaster become a continuous mass on the space-time-magnitude range of interest. We also calculate the upper bound of the gambling score when the true model is a renewal process, the stress release model or the ETAS model and when the reference model is the Poisson model.

  12. Priming us and them: automatic assimilation and contrast in group attitudes.

    PubMed

    Ledgerwood, Alison; Chaiken, Shelly

    2007-12-01

    Social judgment theory holds that a person's own attitudes function as reference points, influencing the perception of others' attitudes. The authors argue that attitudes themselves are influenced by reference points, namely, the presumed attitudes of others. Whereas exposure to a group that acts as a contextual reference should cause attitude assimilation, exposure to a group that acts as a comparative reference should cause attitude contrast. In Study 1, participants subliminally primed with their political ingroup or outgroup endorsed more extreme political positions than did controls. Study 2 demonstrated that prime types known to uniquely facilitate assimilation and contrast enhanced the polarization effect in the ingroup and outgroup conditions, respectively. Study 3 established an important boundary condition for whether group salience produces attitude assimilation or contrast by showing that perceived closeness to the elderly moderates the direction and strength of the group priming effect. The results suggest that the transition from assimilation to contrast occurs when a group ceases to function as a context and becomes a comparison point. Implications for social judgment theory, assimilation and contrast research, and conflict escalation are discussed. (c) 2007 APA, all rights reserved.

  13. Levels at gaging stations

    USGS Publications Warehouse

    Kenney, Terry A.

    2010-01-01

    Operational procedures at U.S. Geological Survey gaging stations include periodic leveling checks to ensure that gages are accurately set to the established gage datum. Differential leveling techniques are used to determine elevations for reference marks, reference points, all gages, and the water surface. The techniques presented in this manual provide guidance on instruments and methods that ensure gaging-station levels are run to both a high precision and accuracy. Levels are run at gaging stations whenever differences in gage readings are unresolved, stations may have been damaged, or according to a pre-determined frequency. Engineer's levels, both optical levels and electronic digital levels, are commonly used for gaging-station levels. Collimation tests should be run at least once a week for any week that levels are run, and the absolute value of the collimation error cannot exceed 0.003 foot/100 feet (ft). An acceptable set of gaging-station levels consists of a minimum of two foresights, each from a different instrument height, taken on at least two independent reference marks, all reference points, all gages, and the water surface. The initial instrument height is determined from another independent reference mark, known as the origin, or base reference mark. The absolute value of the closure error of a leveling circuit must be less than or equal to ft, where n is the total number of instrument setups, and may not exceed |0.015| ft regardless of the number of instrument setups. Closure error for a leveling circuit is distributed by instrument setup and adjusted elevations are determined. Side shots in a level circuit are assessed by examining the differences between the adjusted first and second elevations for each objective point in the circuit. The absolute value of these differences must be less than or equal to 0.005 ft. Final elevations for objective points are determined by averaging the valid adjusted first and second elevations. If final elevations indicate that the reference gage is off by |0.015| ft or more, it must be reset.

  14. Combining statistical inference and decisions in ecology

    USGS Publications Warehouse

    Williams, Perry J.; Hooten, Mevin B.

    2016-01-01

    Statistical decision theory (SDT) is a sub-field of decision theory that formally incorporates statistical investigation into a decision-theoretic framework to account for uncertainties in a decision problem. SDT provides a unifying analysis of three types of information: statistical results from a data set, knowledge of the consequences of potential choices (i.e., loss), and prior beliefs about a system. SDT links the theoretical development of a large body of statistical methods including point estimation, hypothesis testing, and confidence interval estimation. The theory and application of SDT have mainly been developed and published in the fields of mathematics, statistics, operations research, and other decision sciences, but have had limited exposure in ecology. Thus, we provide an introduction to SDT for ecologists and describe its utility for linking the conventionally separate tasks of statistical investigation and decision making in a single framework. We describe the basic framework of both Bayesian and frequentist SDT, its traditional use in statistics, and discuss its application to decision problems that occur in ecology. We demonstrate SDT with two types of decisions: Bayesian point estimation, and an applied management problem of selecting a prescribed fire rotation for managing a grassland bird species. Central to SDT, and decision theory in general, are loss functions. Thus, we also provide basic guidance and references for constructing loss functions for an SDT problem.

  15. The Latin American contribution to the psychoanalytic concept of phantasy.

    PubMed

    de Barros, Izelinda Garcia

    2012-12-01

    The author argues that the ubiquity of phantasies at various levels of mental functioning is undisputed in the current schools of psychoanalytic thought; however, she demonstrates some variations in their understanding of how the psychotherapeutic access to different configurations occurs. In the process of examining and acknowledging the central role played by unconscious phantasies in his patients' symptoms, Freud gradually broadened the vernacular meaning of the German word 'Phantasie' that refers to imagination and the world of imagination, conferring on it the specific features that came to characterize its use in the psychoanalytic vocabulary. Later, the expansion of the concept derived from Melanie Klein's clinical material obtained from child analyses gave rise to important debates. The author discusses the main points of disagreement that led to these debates, as well as their various theoretical and technical implications. Psychoanalytic associations in Latin America were strongly influenced by Klein and her followers. Thus, most of their scientific writings use the concept of unconscious phantasy put forward by the Kleinian school. Taking Kleinian principles as their starting point, Baranger and Baranger made the most original Latin American contribution to the concept of unconscious phantasy with their works on the unconscious phantasies generated by the analytic pair. Copyright © 2012 Institute of Psychoanalysis.

  16. Interior-Point Methods for Linear Programming: A Review

    ERIC Educational Resources Information Center

    Singh, J. N.; Singh, D.

    2002-01-01

    The paper reviews some recent advances in interior-point methods for linear programming and indicates directions in which future progress can be made. Most of the interior-point methods belong to any of three categories: affine-scaling methods, potential reduction methods and central path methods. These methods are discussed together with…

  17. A multicenter study of the accuracy of the One Touch Ultra home glucose meter in children with type 1 diabetes.

    PubMed

    2003-01-01

    Data are not readily available on the accuracy of one of the most commonly used home blood glucose meters, the One Touch Ultra (LifeScan, Milpitas, California). The purpose of this report is to provide information on the accuracy of this home glucose meter in children with type 1 diabetes. During a 24-h clinical research center stay, the accuracy of the Ultra meter was assessed in 91 children, 3-17 years old, with type 1 diabetes by comparing the Ultra glucose values with concurrent reference serum glucose values measured in a central laboratory. The Pearson correlation between the 2,068 paired Ultra and reference values was 0.97, with the median relative absolute difference being 6%. Ninety-four percent of all Ultra values (96% of venous and 84% of capillary samples) met the proposed International Organisation for Standardisation (ISO) standard for instruments used for self-monitoring of glucose when compared with venous reference values. Ninety-nine percent of values were in zones A + B of the Modified Error Grid. A high degree of accuracy was seen across the full range of glucose values. For 353 data points during an insulin-induced hypoglycemia test, the Ultra meter was found to have accuracy that was comparable to concurrently used benchmark instruments (Beckman, YSI, or i-STAT); 95% and 96% of readings from the Ultra meter and the benchmark instruments met the proposed ISO criteria, respectively. These results confirm that the One Touch Ultra meter provides accurate glucose measurements for both hypoglycemia and hyperglycemia in children with type 1 diabetes.

  18. Where Did the Reference Desk Go? Transforming Staff and Space to Meet User Needs

    ERIC Educational Resources Information Center

    Bunnett, Brian; Boehme, Andrea; Hardin, Steve; Arvin, Shelley; Evans, Karen; Huey, Paula; LaBella, Carey

    2016-01-01

    A sharp decline in the number of reference queries prompted the library administration at Indiana State University to begin a project to combine the circulation, reference, and IT desks to reduce staffing at a new consolidated service point. All faculty and staff in the reference/instruction and circulation units participated in the project. The…

  19. Alignment and focus of mirrored facets of a heliosat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yellowhair, Julius E; Ho, Clifford Kuofei; Diver, Richard B

    2013-11-12

    Various technologies pertaining to aligning and focusing mirrored facets of a heliostat are described herein. Updating alignment and/or focus of mirrored facets is undertaken through generation of a theoretical image, wherein the theoretical image is indicative of a reflection of the target via the mirrored facets when the mirrored facets are properly aligned. This theoretical image includes reference points that are overlaid on an image of the target as reflected by the mirrored facets of the heliostat. A technician adjusts alignment/focus of a mirrored facet by causing reflected reference markings to become aligned with the reference points in the theoreticalmore » image.« less

  20. A smart market for nutrient credit trading to incentivize wetland construction

    NASA Astrophysics Data System (ADS)

    Raffensperger, John F.; Prabodanie, R. A. Ranga; Kostel, Jill A.

    2017-03-01

    Nutrient trading and constructed wetlands are widely discussed solutions to reduce nutrient pollution. Nutrient markets usually include agricultural nonpoint sources and municipal and industrial point sources, but these markets rarely include investors who construct wetlands to sell nutrient reduction credits. We propose a new market design for trading nutrient credits, with both point source and non-point source traders, explicitly incorporating the option of landowners to build nutrient removal wetlands. The proposed trading program is designed as a smart market with centralized clearing, done with an optimization. The market design addresses the varying impacts of runoff over space and time, and the lumpiness of wetland investments. We simulated the market for the Big Bureau Creek watershed in north-central Illinois. We found that the proposed smart market would incentivize wetland construction by assuring reasonable payments for the ecosystem services provided. The proposed market mechanism selects wetland locations strategically taking into account both the cost and nutrient removal efficiencies. The centralized market produces locational prices that would incentivize farmers to reduce nutrients, which is voluntary. As we illustrate, wetland builders' participation in nutrient trading would enable the point sources and environmental organizations to buy low cost nutrient credits.

  1. Investigations of Multiple Swirl-Venturi Fuel Injector Concepts: Recent Experimental Optical Measurement Results for 1-Point, 7-Point, and 9-Point Configurations

    NASA Technical Reports Server (NTRS)

    Hicks, Yolanda R.; Anderson, Robert C.; Tedder, Sarah A.; Tacina, Kathleen M.

    2015-01-01

    This paper presents results obtained during testing in optically-accessible, JP8-fueled, flame tube combustors using swirl-venturi lean direct injection (LDI) research hardware. The baseline LDI geometry has 9 fuel/air mixers arranged in a 3 x 3 array within a square chamber. 2-D results from this 9-element array are compared to results obtained in a cylindrical combustor using a 7-element array and a single element. In each case, the baseline element size remains the same. The effect of air swirler angle, and element arrangement on the presence of a central recirculation zone are presented. Only the highest swirl number air swirler produced a central recirculation zone for the single element swirl-venturi LDI and the 9-element LDI, but that same swirler did not produce a central recirculation zone for the 7-element LDI, possibly because of strong interactions due to element spacing within the array.

  2. Removal of central obscuration and spiders for coronagraphy

    NASA Astrophysics Data System (ADS)

    Abe, L.; Nishikawa, J.; Murakami, N.; Tamura, M.

    2006-06-01

    We present a method to remove the central obscuration and spiders, or any kind of geometry inside a telescope pupil. The technique relies on the combination of a first focal plane diffracting mask, and a complex amplitude pupil mask. In this combination, the central obscuration and eventual spider arms patterns in the re-imaged pupil (after the diffracting mask) are filled with coherent light. Adding an appropriate complex amplitude pupil mask allows virtually any kind of pupil shaping (in both amplitude and/or phase). We show that the obtained output pupil can feed a high efficiency coronagraph (any kind) with a very reasonable overall throughput and good performance even when considering pointing errors. In this paper, we specifically assess the performance of this technique when using apodized entrance pupils. This technique is relevant for ground based telescopes foreseeing the advent of higher order (so called ExAO) adaptive optics systems providing very high Strehl ratios. Some feasibility points are also discussed. adaptive optics systems providing very high Strehl ratios. Some feasibility points are also discussed.

  3. Alignment reference device

    DOEpatents

    Patton, Gail Y.; Torgerson, Darrel D.

    1987-01-01

    An alignment reference device provides a collimated laser beam that minimizes angular deviations therein. A laser beam source outputs the beam into a single mode optical fiber. The output end of the optical fiber acts as a source of radiant energy and is positioned at the focal point of a lens system where the focal point is positioned within the lens. The output beam reflects off a mirror back to the lens that produces a collimated beam.

  4. Applying Workspace Limitations in a Velocity-Controlled Robotic Mechanism

    NASA Technical Reports Server (NTRS)

    Abdallah, Muhammad E. (Inventor); Hargrave, Brian (Inventor); Platt, Robert J., Jr. (Inventor)

    2014-01-01

    A robotic system includes a robotic mechanism responsive to velocity control signals, and a permissible workspace defined by a convex-polygon boundary. A host machine determines a position of a reference point on the mechanism with respect to the boundary, and includes an algorithm for enforcing the boundary by automatically shaping the velocity control signals as a function of the position, thereby providing smooth and unperturbed operation of the mechanism along the edges and corners of the boundary. The algorithm is suited for application with higher speeds and/or external forces. A host machine includes an algorithm for enforcing the boundary by shaping the velocity control signals as a function of the reference point position, and a hardware module for executing the algorithm. A method for enforcing the convex-polygon boundary is also provided that shapes a velocity control signal via a host machine as a function of the reference point position.

  5. eLISA Telescope In-field Pointing and Scattered Light Study

    NASA Astrophysics Data System (ADS)

    Livas, J.; Sankar, S.; West, G.; Seals, L.; Howard, J.; Fitzsimons, E.

    2017-05-01

    The orbital motion of the three spacecraft that make up the eLISA Observatory constellation causes long-arm line of sight variations of approximately ± one degree over the course of a year. The baseline solution is to package the telescope, the optical bench, and the gravitational reference sensor (GRS) into an optical assembly at each end of the measurement arm, and then to articulate the assembly. An optical phase reference is exchanged between the moving optical benches with a single mode optical fiber (“backlink” fiber). An alternative solution, referred to as in-field pointing, embeds a steering mirror into the optical design, fixing the optical benches and eliminating the backlink fiber, but requiring the additional complication of a two-stage optical design for the telescope. We examine the impact of an in-field pointing design on the scattered light performance.

  6. Assessment of Central Retinal Sensitivity Employing Two Types of Microperimetry Devices

    PubMed Central

    Liu, Hongting; Bittencourt, Millena G.; Wang, Jiangxia; Sophie, Raafay; Annam, Rachel; Ibrahim, Mohamed A.; Sepah, Yasir J.; Moradi, Ahmadreza; Scholl, Hendrik P. N.; Nguyen, Quan Dong

    2014-01-01

    Purpose To compare the retinal sensitivity measurements obtained with two microperimeters, the Micro-Perimeter 1 (MP-1) and the Optos optical coherence tomography (OCT)/scanning laser ophthalmoscope (SLO) in subjects with and without maculopathies. Methods Forty-five eyes with no known ocular disease and 47 eyes with maculopathies were examined using both microperimeters. A contrast-adjusted scale was applied to resolve the different stimuli and background luminance existing between the two devices. Results There was a strong ceiling effect with the MP-1 in the healthy group, with 90.1% (1136 of 1260) test points clustered at 20 dB. The mean sensitivity for the corresponding points in the OCT/SLO was 25.8 ± 1.9 dB. A floor effect was also observed with the OCT/SLO in the maculopathy group with 9.7% (128 of 1316) points clustered at 9-dB values. The corresponding mean sensitivity in the MP-1 was 1.7 ± 3.9 dB. A regression equation between the two microperimeters was established in the common 10 to19 dB intervals as: OCT/SLO = 15.6 + 0.564 × MP-1 − 0.009 × MP-12 + k (k is an individual point constant; MP-1 coefficient P < 0.001; MP-12 coefficient P = 0.006). Conclusion The OCT/SLO and the MP-1 provide two different ranges of contrasts for microperimetry examination. Broadening the dynamic range may minimize the constraint of the ceiling and floor effect. There is a significant mathematical relationship in the common interval of the contrast scale. Translational Relevance Applying a unified and broadened dynamic range in different types of microperimeters will help to generate consistent clinical reference for measurements. PMID:25237592

  7. Financial and economic determinants of collective action: The case of wastewater management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brunner, Norbert, E-mail: norbert.brunner@cemds.org; Starkl, Markus, E-mail: markus.starkl@boku.ac.at

    Where public environmental funds support development of wastewater infrastructure, funding institutions ensure the economic use of funds, while the beneficiaries minimize their own costs. In rural areas, there is often a choice between decentralized or centralized (multi-village) systems: if the centralized system is most economic, then only this system is eligible for public funding. However, its implementation requires a voluntary cooperation of the concerned communities, who need to organize themselves to develop and run the infrastructure. The paper analyzes the social determinants of collaboration in a generic case study, using the following variables: method of (economic) assessment, modeled by themore » social discount rate, funding policy, modeled by the funding rate, and users' self-organization, modeled by cost sharing. In a borderline situation, where the centralized system turns out to be most economic, but this assessment is contingent on the assessment method, collective action may fail: the advantages of collective action from funding are too small to outweigh organizational deficiencies. Considering in this situation sanitation as a human right, authors recommend using innovative forms of organization and, if these fail, reassessing either the amount of funding or the eligibility for funding of more acceptable alternatives. - Highlights: Black-Right-Pointing-Pointer A generic case study models collective action and funding in wastewater management. Black-Right-Pointing-Pointer Determinants of success: economic assessment, funding policy and self-organization. Black-Right-Pointing-Pointer Success indicators: conflict rate, funds needed to make cost shares fair. Black-Right-Pointing-Pointer Method for analyzing centralized vs. decentralized disputes. Black-Right-Pointing-Pointer If collective action has less benefits, innovative cost sharing may ensure success.« less

  8. Reference-point-independent dynamics of molecular liquids and glasses in the tensorial formalism

    NASA Astrophysics Data System (ADS)

    Schilling, Rolf

    2002-05-01

    We apply the tensorial formalism to the dynamics of molecular liquids and glasses. This formalism separates the degrees of freedom into translational and orientational ones. Using the Mori-Zwanzig projection formalism, the equations of motion for the tensorial density correlators Slmn,l'm'n'(q-->,t) are derived. For this we show how to choose the slow variables such that the resulting Mori-Zwanzig equations are covariant under a change of the reference point of the body fixed frame. We also prove that the memory kernels obtained from mode-coupling theory (MCT) including all approximations preserve the covariance. This covariance makes, e.g., the glass transition point, the two universal scaling laws and particularly the corresponding exponents independent on the reference point and on the mass and moments of inertia, i.e., they only depend on the properties of the potential energy landscape. Finally, we show that the corresponding MCT questions for linear molecules can be obtained from those for arbitrary molecules and that they differ from earlier equations that are not covariant.

  9. Conventional external beam radiotherapy for central nervous system malignancies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halperin, E.C.; Burger, P.C.

    1985-11-01

    Fractionated external beam photon radiotherapy is an important component of the clinical management of malignant disease of the central nervous system. The practicing neurologist or neurosurgeon frequently relies on the consultative and treatment skills of a radiotherapist. This article provides a review for the nonradiotherapist of the place of conventional external beam radiotherapy in neuro-oncology. 23 references.

  10. Abundances of apple maggot, Rhagoletis pomonella, across different areas in central Washington, with special reference to black-fruited hawthorns

    USDA-ARS?s Scientific Manuscript database

    The apple maggot fly, Rhagoletis pomonella (Walsh), has infested native black-fruited hawthorn (mostly Crataegus douglasii Lindl.) in central Washington since at least 2003, but little is known about the fly’s ecology in hawthorns there. The main objective here was to determine adult and larval abu...

  11. Referent Salience Affects Second Language Article Use

    ERIC Educational Resources Information Center

    Trenkic, Danijela; Pongpairoj, Nattama

    2013-01-01

    The effect of referent salience on second language (L2) article production in real time was explored. Thai (-articles) and French (+articles) learners of English described dynamic events involving two referents, one visually cued to be more salient at the point of utterance formulation. Definiteness marking was made communicatively redundant with…

  12. "In Your Face" Reference Service.

    ERIC Educational Resources Information Center

    Lipow, Anne Grodzins

    1999-01-01

    Discusses changes in library reference service that have occurred with growing Internet use. Topics include the human factor that is still needed; the nature of reference questions; the goal of user self-sufficiency; the invisible nature of much of librarians' work; and providing real-time, interactive point-of-need service to remote users. (LRW)

  13. Quantum critical environment assisted quantum magnetometer

    NASA Astrophysics Data System (ADS)

    Jaseem, Noufal; Omkar, S.; Shaji, Anil

    2018-04-01

    A central qubit coupled to an Ising ring of N qubits, operating close to a critical point is investigated as a potential precision quantum magnetometer for estimating an applied transverse magnetic field. We compute the quantum Fisher information for the central, probe qubit with the Ising chain initialized in its ground state or in a thermal state. The non-unitary evolution of the central qubit due to its interaction with the surrounding Ising ring enhances the accuracy of the magnetic field measurement. Near the critical point of the ring, Heisenberg-like scaling of the precision in estimating the magnetic field is obtained when the ring is initialized in its ground state. However, for finite temperatures, the Heisenberg scaling is limited to lower ranges of N values.

  14. Land Cover Analysis of Temperate Asia

    NASA Technical Reports Server (NTRS)

    Justice, Chris

    1998-01-01

    Satellite data from the advanced very high resolution radiometer (AVHRR) instrument were used to produce a general land cover distribution of temperate Asia (referred to hence as Central Asia) from 1982, starting with the NOAA-7 satellite, and continuing through 1991, ending with the NOAA-11 satellite. Emphasis was placed upon delineating the and and semi-arid zones of Central Asia (largely Mongolia and adjacent areas), mapping broad categories of aggregated land cover, and upon studying photosynthetic capacity increases in Central Asia from 1982 to 1991.

  15. Isolated central diabetes insipidus in a newborn with congenital toxoplasmosis.

    PubMed

    Karadag, Ahmet; Erdeve, Omer; Atasay, Begum; Arsan, Saadet; Deda, Gulhis; Ince, Erdal; Ocal, Gonul; Berberoglu, Merih

    2006-02-01

    We present a 5 day-old male newborn with isolated central diabetes insipidus due to congenital toxoplasmosis. This patient was referred to us for hydrocephalus. As we investigated the aetiology of the hydrocephalus, the patient's serum and cerebrospinal fluid tested positive for toxoplasmosis via ELISA and polymerase chain reaction. Computed tomography showed obstructive hydrocephalus and disseminated cranial calcifications. Central diabetes insipidus developed on the 10th day, apparently as a result of the toxoplasmosis infection, and was treated successfully with oral desmopressin.

  16. Central Administrations of Public Multi-Campus College and University Systems. Core Functions and Cost Pressures with Reference to the Central Administration of the State University of New York. Studies in Public Higher Education. Number 1.

    ERIC Educational Resources Information Center

    Johnstone, D. Bruce

    This essay examines the administration of public multi-campus universities, focusing in particular on central administration and the State University of New York (SUNY) system and on responses to the need for fiscal austerity. Before treatment of the main topic begins, the essay offers a look at five reasons for the suspicion and resentment that…

  17. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  18. Grimm's Law Revisited: A Case for Natural, Typological Phonology.

    ERIC Educational Resources Information Center

    Caflisch, Jacob, Sr.

    1990-01-01

    Reviews and comments on the major points made in Albert Gessman's paper, "Grimm's Law: Fact or Myth?" Through the evaluation of the paper's 13 points, several ideas are pointed out that are believed to be crucial to Gessman's arguments. (29 references) (GLR)

  19. SN 1986J VLBI. IV. The Nature of the Central Component

    NASA Astrophysics Data System (ADS)

    Bietenholz, Michael F.; Bartel, Norbert

    2017-12-01

    We report on Very Large Array measurements between 1 and 45 GHz of the evolving radio spectral energy distribution (SED) of SN 1986J, made in conjunction with very long baseline interferometry (VLBI) imaging. The SED of SN 1986J is unique among supernovae, and shows an inversion point and a high-frequency turnover. Both are due to the central component seen in the VLBI images, and both are progressing downward in frequency with time. The optically thin spectral index of the central component is almost the same as that of the shell. We fit a simple model to the evolving SED consisting of an optically thin shell and a partly absorbed central component. The evolution of the SED is consistent with that of a homologously expanding system. Both components are fading, but the shell is fading more rapidly. We conclude that the central component is physically inside the expanding shell, and not a surface hotspot central only in projection. Our observations are consistent with the central component being due to interaction of the shock with the dense and highly structured circumstellar medium that resulted from a period of common-envelope evolution of the progenitor. However, a young pulsar-wind nebula or emission from an accreting black hole can also not be ruled out at this point.

  20. Centrality measures highlight proton traps and access points to proton highways in kinetic Monte Carlo trajectories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krueger, Rachel A.; Haibach, Frederick G.; Fry, Dana L.

    2015-04-21

    A centrality measure based on the time of first returns rather than the number of steps is developed and applied to finding proton traps and access points to proton highways in the doped perovskite oxides: AZr{sub 0.875}D{sub 0.125}O{sub 3}, where A is Ba or Sr and the dopant D is Y or Al. The high centrality region near the dopant is wider in the SrZrO{sub 3} systems than the BaZrO{sub 3} systems. In the aluminum-doped systems, a region of intermediate centrality (secondary region) is found in a plane away from the dopant. Kinetic Monte Carlo (kMC) trajectories show that thismore » secondary region is an entry to fast conduction planes in the aluminum-doped systems in contrast to the highest centrality area near the dopant trap. The yttrium-doped systems do not show this secondary region because the fast conduction routes are in the same plane as the dopant and hence already in the high centrality trapped area. This centrality measure complements kMC by highlighting key areas in trajectories. The limiting activation barriers found via kMC are in very good agreement with experiments and related to the barriers to escape dopant traps.« less

  1. A color prediction model for imagery analysis

    NASA Technical Reports Server (NTRS)

    Skaley, J. E.; Fisher, J. R.; Hardy, E. E.

    1977-01-01

    A simple model has been devised to selectively construct several points within a scene using multispectral imagery. The model correlates black-and-white density values to color components of diazo film so as to maximize the color contrast of two or three points per composite. The CIE (Commission Internationale de l'Eclairage) color coordinate system is used as a quantitative reference to locate these points in color space. Superimposed on this quantitative reference is a perceptional framework which functionally contrasts color values in a psychophysical sense. This methodology permits a more quantitative approach to the manual interpretation of multispectral imagery while resulting in improved accuracy and lower costs.

  2. Essential tremor

    MedlinePlus

    ... Tremor - familial; Benign essential tremor; Shaking - essential tremor Images Central nervous system and peripheral nervous system References Jankovic J. Parkinson disease and other movement disorders. In: Daroff ...

  3. Olivopontocerebellar atrophy

    MedlinePlus

    ... degeneration; Multiple system atrophy cerebellar predominance; MSA-C Images Central nervous system and peripheral nervous system References Jankovic J, Lang AE. Diagnosis and assessment of Parkinson disease ...

  4. Secondary parkinsonism

    MedlinePlus

    ... developing. Alternative Names Parkinsonism - secondary; Atypical Parkinson disease Images Central nervous system and peripheral nervous system References Jankovic J. Parkinson disease and other movement disorders. In: Daroff ...

  5. Movement - uncontrollable

    MedlinePlus

    ... movements; Body movements - uncontrollable; Dyskinesia; Athetosis; Myoclonus; Ballismus Images Central nervous system and peripheral nervous system References Jankovic J, Lang AE. Diagnosis and assessment of Parkinson disease ...

  6. Error assessment of local tie vectors in space geodesy

    NASA Astrophysics Data System (ADS)

    Falkenberg, Jana; Heinkelmann, Robert; Schuh, Harald

    2014-05-01

    For the computation of the ITRF, the data of the geometric space-geodetic techniques on co-location sites are combined. The combination increases the redundancy and offers the possibility to utilize the strengths of each technique while mitigating their weaknesses. To enable the combination of co-located techniques each technique needs to have a well-defined geometric reference point. The linking of the geometric reference points enables the combination of the technique-specific coordinate to a multi-technique site coordinate. The vectors between these reference points are called "local ties". The realization of local ties is usually reached by local surveys of the distances and or angles between the reference points. Identified temporal variations of the reference points are considered in the local tie determination only indirectly by assuming a mean position. Finally, the local ties measured in the local surveying network are to be transformed into the ITRF, the global geocentric equatorial coordinate system of the space-geodetic techniques. The current IERS procedure for the combination of the space-geodetic techniques includes the local tie vectors with an error floor of three millimeters plus a distance dependent component. This error floor, however, significantly underestimates the real accuracy of local tie determination. To fullfill the GGOS goals of 1 mm position and 0.1 mm/yr velocity accuracy, an accuracy of the local tie will be mandatory at the sub-mm level, which is currently not achievable. To assess the local tie effects on ITRF computations, investigations of the error sources will be done to realistically assess and consider them. Hence, a reasonable estimate of all the included errors of the various local ties is needed. An appropriate estimate could also improve the separation of local tie error and technique-specific error contributions to uncertainties and thus access the accuracy of space-geodetic techniques. Our investigations concern the simulation of the error contribution of each component of the local tie definition and determination. A closer look into the models of reference point definition, of accessibility, of measurement, and of transformation is necessary to properly model the error of the local tie. The effect of temporal variations on the local ties will be studied as well. The transformation of the local survey into the ITRF can be assumed to be the largest error contributor, in particular the orientation of the local surveying network to the ITRF.

  7. Estimation of an accuracy index of a diagnostic biomarker when the reference biomarker is continuous and measured with error.

    PubMed

    Wu, Mixia; Zhang, Dianchen; Liu, Aiyi

    2016-01-01

    New biomarkers continue to be developed for the purpose of diagnosis, and their diagnostic performances are typically compared with an existing reference biomarker used for the same purpose. Considerable amounts of research have focused on receiver operating characteristic curves analysis when the reference biomarker is dichotomous. In the situation where the reference biomarker is measured on a continuous scale and dichotomization is not practically appealing, an index was proposed in the literature to measure the accuracy of a continuous biomarker, which is essentially a linear function of the popular Kendall's tau. We consider the issue of estimating such an accuracy index when the continuous reference biomarker is measured with errors. We first investigate the impact of measurement errors on the accuracy index, and then propose methods to correct for the bias due to measurement errors. Simulation results show the effectiveness of the proposed estimator in reducing biases. The methods are exemplified with hemoglobin A1c measurements obtained from both the central lab and a local lab to evaluate the accuracy of the mean data obtained from the metered blood glucose monitoring against the centrally measured hemoglobin A1c from a behavioral intervention study for families of youth with type 1 diabetes.

  8. A note on libration point orbits, temporary capture and low-energy transfers

    NASA Astrophysics Data System (ADS)

    Fantino, E.; Gómez, G.; Masdemont, J. J.; Ren, Y.

    2010-11-01

    In the circular restricted three-body problem (CR3BP) the weak stability boundary (WSB) is defined as a boundary set in the phase space between stable and unstable motion relative to the second primary. At a given energy level, the boundaries of such region are provided by the stable manifolds of the central objects of the L1 and L2 libration points, i.e., the two planar Lyapunov orbits. Besides, the unstable manifolds of libration point orbits (LPOs) around L1 and L2 have been identified as responsible for the weak or temporary capture around the second primary of the system. These two issues suggest the existence of natural dynamical channels between the Earth's vicinity and the Sun-Earth libration points L1 and L2. Furthermore, it has been shown that the Sun-Earth L2 central unstable manifolds can be linked, through an heteroclinic connection, to the central stable manifolds of the L2 point in the Earth-Moon three-body problem. This concept has been applied to the design of low energy transfers (LETs) from the Earth to the Moon. In this contribution we consider all the above three issues, i.e., weak stability boundaries, temporary capture and low energy transfers, and we discuss the role played by the invariant manifolds of LPOs in each of them. The study is made in the planar approximation.

  9. Pointing at targets by children with congenital and transient blindness.

    PubMed

    Gaunet, Florence; Ittyerah, Miriam; Rossetti, Yves

    2007-04-01

    The study investigated pointing at memorized targets in reachable space in congenitally blind (CB) and blindfolded sighted (BS) children (6, 8, 10 and 12 years; ten children in each group). The target locations were presented on a sagittal plane by passive positioning of the left index finger. A go signal for matching the target location with the right index finger was provided 0 or 4 s after demonstration. An age effect was found only for absolute distance errors and the surface area of pointing was smaller for the CB children. Results indicate that early visual experience and age are not predictive factors for pointing in children. The delay was an important factor at all ages and for both groups, indicating distinct spatial representations such as egocentric and allocentric frames of reference, for immediate and delayed pointing, respectively. Therefore, the CB like the BS children are able to use both ego- and allocentric frames of reference.

  10. In-flight photogrammetric camera calibration and validation via complementary lidar

    NASA Astrophysics Data System (ADS)

    Gneeniss, A. S.; Mills, J. P.; Miller, P. E.

    2015-02-01

    This research assumes lidar as a reference dataset against which in-flight camera system calibration and validation can be performed. The methodology utilises a robust least squares surface matching algorithm to align a dense network of photogrammetric points to the lidar reference surface, allowing for the automatic extraction of so-called lidar control points (LCPs). Adjustment of the photogrammetric data is then repeated using the extracted LCPs in a self-calibrating bundle adjustment with additional parameters. This methodology was tested using two different photogrammetric datasets, a Microsoft UltraCamX large format camera and an Applanix DSS322 medium format camera. Systematic sensitivity testing explored the influence of the number and weighting of LCPs. For both camera blocks it was found that when the number of control points increase, the accuracy improves regardless of point weighting. The calibration results were compared with those obtained using ground control points, with good agreement found between the two.

  11. 47 CFR 52.7 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Administration § 52.7 Definitions. As used in this subpart: (a) Area code or numbering plan area (NPA). The term “area code or numbering plan area” refers to the first three digits (NXX) of a ten-digit telephone... “central office code” refers to the second three digits (NXX) of a ten-digit telephone number in the form...

  12. 47 CFR 52.7 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Administration § 52.7 Definitions. As used in this subpart: (a) Area code or numbering plan area (NPA). The term “area code or numbering plan area” refers to the first three digits (NXX) of a ten-digit telephone... “central office code” refers to the second three digits (NXX) of a ten-digit telephone number in the form...

  13. 47 CFR 52.7 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Administration § 52.7 Definitions. As used in this subpart: (a) Area code or numbering plan area (NPA). The term “area code or numbering plan area” refers to the first three digits (NXX) of a ten-digit telephone... “central office code” refers to the second three digits (NXX) of a ten-digit telephone number in the form...

  14. 47 CFR 52.7 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Administration § 52.7 Definitions. As used in this subpart: (a) Area code or numbering plan area (NPA). The term “area code or numbering plan area” refers to the first three digits (NXX) of a ten-digit telephone... “central office code” refers to the second three digits (NXX) of a ten-digit telephone number in the form...

  15. Social Psychology of Second Language Acquisition and Bilinguality: An Annotated Bibliography. Research Bulletin No. 340.

    ERIC Educational Resources Information Center

    Desrochers, Alain M.; And Others

    This bibliography includes 333 annotated references and 178 references without annotations. The articles represent a wide variety of work, including theoretical papers, statements of opinions and policy (both political and pedagogical), and empirical studies. The central theme was organized into six topics, which were then used as major categories…

  16. Centrality Evolution of pt and yt Spectra from Au-Au Collisions at √ {sNN} = 200 GeV

    NASA Astrophysics Data System (ADS)

    Trainor, Thomas A.

    A two-component analysis of spectra to pt = 12 GeV/c for identified pions and protons from 200 GeV Au-Au collisions is presented. The method is similar to an analysis of the nch dependence of pt spectra from p-p collisions at 200 GeV, but applied to Au-Au centrality dependence. The soft-component reference is a Lévy distribution on transverse mass mt. The hard-component reference is a Gaussian on transverse rapidity yt with exponential (pt power-law) tail. Deviations of data from the reference are described by hard-component ratio rAA, which generalizes nuclear modification factor RAA. The analysis suggests that centrality evolution of pion and proton spectra is dominated by changes in parton fragmentation. The structure of rAA suggests that parton energy loss produces a negative boost Δyt of a large fraction (but not all) of the minimum-bias fragment distribution, and that lower-energy partons suffer relatively less energy loss, possibly due to color screening. The analysis also suggests that the anomalous p/π ratio may be due to differences in the parton energy-loss process experienced by the two hadron species. This analysis provides no evidence for radial flow.

  17. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy: Impact on Prices, Spending, and Surgical Complications.

    PubMed

    Robinson, James C; Brown, Timothy T; Whaley, Christopher; Bozic, Kevin J

    2015-09-16

    Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. We obtained data on 3962 patients covered by the California Public Employees' Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, -24.9% to -9.6%) for knee procedures and by 17.0% (95% confidence interval, -29.3% to -2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Consumer Choice Between Hospital-Based and Freestanding Facilities for Arthroscopy

    PubMed Central

    Robinson, James C.; Brown, Timothy T.; Whaley, Christopher; Bozic, Kevin J.

    2015-01-01

    Background: Hospital-based outpatient departments traditionally charge higher prices for ambulatory procedures, compared with freestanding surgery centers. Under emerging reference-based benefit designs, insurers establish a contribution limit that they will pay, requiring the patient to pay the difference between that contribution limit and the actual price charged by the facility. The purpose of this study was to evaluate the impact of reference-based benefits on consumer choices, facility prices, employer spending, and surgical outcomes for orthopaedic procedures performed at ambulatory surgery centers. Methods: We obtained data on 3962 patients covered by the California Public Employees’ Retirement System (CalPERS) who underwent arthroscopy of the knee or shoulder in the three years prior to the implementation of reference-based benefits in January 2012 and on 2505 patients covered by CalPERS who underwent arthroscopy in the two years after implementation. Control group data were obtained on 57,791 patients who underwent arthroscopy and were not subject to reference-based benefits. The impact of reference-based benefits on consumer choices between hospital-based and freestanding facilities, facility prices, employer spending, and surgical complications was assessed with use of difference-in-differences multivariable regressions to adjust for patient demographic characteristics, comorbidities, and geographic location. Results: By the second year of the program, the shift to reference-based benefits was associated with an increase in the utilization of freestanding ambulatory surgery centers by 14.3 percentage points (95% confidence interval, 8.1 to 20.5 percentage points) for knee arthroscopy and by 9.9 percentage points (95% confidence interval, 3.2 to 16.7 percentage points) for shoulder arthroscopy and a corresponding decrease in the use of hospital-based facilities. The mean price paid by CalPERS fell by 17.6% (95% confidence interval, −24.9% to −9.6%) for knee procedures and by 17.0% (95% confidence interval, −29.3% to −2.5%) for shoulder procedures. The shift to reference-based benefits was not associated with a change in the rate of surgical complications. In the first two years after the implementation of reference-based benefits, CalPERS saved $2.3 million (13%) on these two orthopaedic procedures. Conclusions: Reference-based benefits increase consumer sensitivity to price differences between freestanding and hospital-based surgical facilities. Clinical Relevance: This study shows that the implementation of reference-based benefits does not result in a significant increase in measured complication rates for those subject to reference-based benefits. PMID:26378263

  19. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  20. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  1. 50 CFR Appendix B to Part 622 - Gulf Areas

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Restricted Area Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters...—Offshore 26°26.0′ 82°59.0′ 4West of Egmont Key 27°30.0′ 83°21.5′ 5Off Anclote Keys—Offshore 28°10.0′ 83°45... Point No. and reference location 1 North lat. West long. 1Seaward limit of Florida's waters northeast of...

  2. Runtime Support for Type-Safe Dynamic Java Classes

    DTIC Science & Technology

    2000-01-01

    Section 4.3. For each dynamic class C, we create a proxy class, Cproxy, and an implementation class, Cimp . In order to wrap method calls, Cproxy...wrapper method (W) and a reference to the associated method body (M). W explicitly invokes M, which points to the corresponding method body in Cimp ...When C’s implementation Cimp is switched, M is updated to point to the corresponding method object in the new C imp. Cproxy also contains a reference

  3. Experimental Estimating Deflection of a Simple Beam Bridge Model Using Grating Eddy Current Sensors

    PubMed Central

    Lü, Chunfeng; Liu, Weiwen; Zhang, Yongjie; Zhao, Hui

    2012-01-01

    A novel three-point method using a grating eddy current absolute position sensor (GECS) for bridge deflection estimation is proposed in this paper. Real spatial positions of the measuring points along the span axis are directly used as relative reference points of each other rather than using any other auxiliary static reference points for measuring devices in a conventional method. Every three adjacent measuring points are defined as a measuring unit and a straight connecting bar with a GECS fixed on the center section of it links the two endpoints. In each measuring unit, the displacement of the mid-measuring point relative to the connecting bar measured by the GECS is defined as the relative deflection. Absolute deflections of each measuring point can be calculated from the relative deflections of all the measuring units directly without any correcting approaches. Principles of the three-point method and displacement measurement of the GECS are introduced in detail. Both static and dynamic experiments have been carried out on a simple beam bridge model, which demonstrate that the three-point deflection estimation method using the GECS is effective and offers a reliable way for bridge deflection estimation, especially for long-term monitoring. PMID:23112583

  4. Experimental estimating deflection of a simple beam bridge model using grating eddy current sensors.

    PubMed

    Lü, Chunfeng; Liu, Weiwen; Zhang, Yongjie; Zhao, Hui

    2012-01-01

    A novel three-point method using a grating eddy current absolute position sensor (GECS) for bridge deflection estimation is proposed in this paper. Real spatial positions of the measuring points along the span axis are directly used as relative reference points of each other rather than using any other auxiliary static reference points for measuring devices in a conventional method. Every three adjacent measuring points are defined as a measuring unit and a straight connecting bar with a GECS fixed on the center section of it links the two endpoints. In each measuring unit, the displacement of the mid-measuring point relative to the connecting bar measured by the GECS is defined as the relative deflection. Absolute deflections of each measuring point can be calculated from the relative deflections of all the measuring units directly without any correcting approaches. Principles of the three-point method and displacement measurement of the GECS are introduced in detail. Both static and dynamic experiments have been carried out on a simple beam bridge model, which demonstrate that the three-point deflection estimation method using the GECS is effective and offers a reliable way for bridge deflection estimation, especially for long-term monitoring.

  5. Progressive supranuclear palsy

    MedlinePlus

    ... dystonia; Richardson-Steele-Olszewski syndrome; Palsy - progressive supranuclear Images Central nervous system and peripheral nervous system References Jankovic J. Parkinson disease and other movement disorders. In: Daroff ...

  6. Neural blockade during exercise augments central command's contribution to carotid baroreflex resetting

    NASA Technical Reports Server (NTRS)

    Querry, R. G.; Smith, S. A.; Stromstad, M.; Ide, K.; Raven, P. B.; Secher, N. H.

    2001-01-01

    This investigation was designed to determine central command's role on carotid baroreflex (CBR) resetting during exercise. Nine volunteer subjects performed static and rhythmic handgrip exercise at 30 and 40% maximal voluntary contraction (MVC), respectively, before and after partial axillary neural blockade. Stimulus-response curves were developed using the neck pressure-neck suction technique and a rapid pulse train protocol (+40 to -80 Torr). Regional anesthesia resulted in a significant reduction in MVC. Heart rate (HR) and ratings of perceived exertion (RPE) were used as indexes of central command and were elevated during exercise at control force intensity after induced muscle weakness. The CBR function curves were reset vertically with a minimal lateral shift during control exercise and exhibited a further parallel resetting during exercise with neural blockade. The operating point was progressively reset to coincide with the centering point of the CBR curve. These data suggest that central command was a primary mechanism in the resetting of the CBR during exercise. However, it appeared that central command modulated the carotid-cardiac reflex proportionately more than the carotid-vasomotor reflex.

  7. F-16 Low Altitude Navigation and Targeting Infrared System for Night (LANTIRN) and the Night Close Air Support (CAS) Mission

    DTIC Science & Technology

    1989-06-02

    physical reference can be a natural feature, river bend, distinctly shaped wooded area, or lake. Artificial references such as colored smoke or...fluorescent ground panels can also be placed instead of, or as an aid to recognition of the natural feature.ដ> But, artificial references that are effective...Government Printin-gOffice, 1959. Central Intelligence Agenc7. National Intellignece Survey, East Germany, Section 23, Weather and Climate. Washington

  8. WHO Melting-Point Reference Substances

    PubMed Central

    Bervenmark, H.; Diding, N. Å.; Öhrner, B.

    1963-01-01

    Batches of 13 highly purified chemicals, intended for use as reference substances in the calibration of apparatus for melting-point determinations, have been subjected to a collaborative assay by 15 laboratories in 13 countries. All the laboratories performed melting-point determinations by the capillary methods described in the proposed text for the second edition of the Pharmacopoea Internationalis and some, in addition, carried out determinations by the microscope hot stage (Kofler) method, using both the “going-through” and the “equilibrium” technique. Statistical analysis of the data obtained by the capillary method showed that the within-laboratory variation was small and that the between-laboratory variation, though constituting the greatest part of the whole variance, was not such as to warrant the exclusion of any laboratory from the evaluation of the results. The average values of the melting-points obtained by the laboratories can therefore be used as constants for the substances in question, which have accordingly been established as WHO Melting-Point Reference Substances and included in the WHO collection of authentic chemical substances. As to the microscope hot stage method, analysis of the results indicated that the values obtained by the “going-through” technique did not differ significantly from those obtained by the capillary method, but the values obtained by the “equilibrium” technique were mostly significantly lower. PMID:20604137

  9. Hierarchical motion organization in random dot configurations

    NASA Technical Reports Server (NTRS)

    Bertamini, M.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)

    2000-01-01

    Motion organization has 2 aspects: the extraction of a (moving) frame of reference and the hierarchical organization of moving elements within the reference frame. Using a discrimination of relative motions task, the authors found large differences between different types of motion (translation, divergence, and rotation) in the degree to which each can serve as a moving frame of reference. Translation and divergence are superior to rotation. There are, however, situations in which rotation can serve as a reference frame. This is due to the presence of a second factor, structural invariants (SIs). SIs are spatial relationships persisting among the elements within a configuration such as a collinearity among points or one point coinciding with the center of rotation for another (invariant radius). The combined effect of these 2 factors--motion type and SIs-influences perceptual motion organization.

  10. Elastic-wave-mode separation in TTI media with inverse-distance weighted interpolation involving position shading

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Meng, Xiaohong; Zheng, Wanqiu

    2017-10-01

    The elastic-wave reverse-time migration of inhomogeneous anisotropic media is becoming the hotspot of research today. In order to ensure the accuracy of the migration, it is necessary to separate the wave mode into P-wave and S-wave before migration. For inhomogeneous media, the Kelvin-Christoffel equation can be solved in the wave-number domain by using the anisotropic parameters of the mesh nodes, and the polarization vector of the P-wave and S-wave at each node can be calculated and transformed into the space domain to obtain the quasi-differential operators. However, this method is computationally expensive, especially for the process of quasi-differential operators. In order to reduce the computational complexity, the wave-mode separation of mixed domain can be realized on the basis of a reference model in the wave-number domain. But conventional interpolation methods and reference model selection methods reduce the separation accuracy. In order to further improve the separation effect, this paper introduces an inverse-distance interpolation method involving position shading and uses the reference model selection method of random points scheme. This method adds the spatial weight coefficient K, which reflects the orientation of the reference point on the conventional IDW algorithm, and the interpolation process takes into account the combined effects of the distance and azimuth of the reference points. Numerical simulation shows that the proposed method can separate the wave mode more accurately using fewer reference models and has better practical value.

  11. [The distribution of the tsetse fly (Diptera: Glossinidae) in the humid savanna zone (Central African Republic). Evaluation of prospective entomological techniques].

    PubMed

    Blanc, F; Gouteux, J P; Cuisance, D; Pounekrozou, E; N'Dokoué, F; Le Gall, F

    1991-06-01

    Two trapping methods were compared during a survey of the distribution of tsetse flies in the Mbororo cattle breeding area of the Central African Republic: (a) several traps dispersed throughout the riverine forest galleries and remaining only one day at each site: (b) one sentinel trap placed at the cattle drinking point and remaining for several days. The latter method was more reliable and is therefore recommended. The concentration of tsetse flies at the drinking points was negligible during the rainy season.

  12. Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

    DOEpatents

    Ohmacht, Martin

    2017-08-15

    In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

  13. Generation-based memory synchronization in a multiprocessor system with weakly consistent memory accesses

    DOEpatents

    Ohmacht, Martin

    2014-09-09

    In a multiprocessor system, a central memory synchronization module coordinates memory synchronization requests responsive to memory access requests in flight, a generation counter, and a reclaim pointer. The central module communicates via point-to-point communication. The module includes a global OR reduce tree for each memory access requesting device, for detecting memory access requests in flight. An interface unit is implemented associated with each processor requesting synchronization. The interface unit includes multiple generation completion detectors. The generation count and reclaim pointer do not pass one another.

  14. Staffing by Design: A Methodology for Staffing Reference

    ERIC Educational Resources Information Center

    Ward, David; Phetteplace, Eric

    2012-01-01

    The growth in number and kind of online reference services has resulted in both new users consulting library research services as well as new patterns of service use. Staffing in-person and virtual reference services desks adequately requires a systematic analysis of patterns of use across service points in order to successfully meet fluctuating…

  15. 27 CFR 9.152 - Malibu-Newton Canyon.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ....” (2) Then south along Kanan Dume Road to the point where an unnamed, unimproved dirt road referred to... Canyon Road to an unnamed, unimproved dirt road referred to by the petitioner as Newton Mountain Way at... southeastern ridgeline of Newton Canyon, to an unnamed, unimproved dirt road referred to by the petitioner as...

  16. Evaluation of six TPS algorithms in computing entrance and exit doses

    PubMed Central

    Metwaly, Mohamed; Glegg, Martin; Baggarley, Shaun P.; Elliott, Alex

    2014-01-01

    Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC). Measurements with ionization chamber (IC) and diode detector in water phantoms were used as a reference. Comparisons were done in terms of central axis point dose, 1D relative profiles, and 2D absolute gamma analysis. Entrance doses computed by all TPS algorithms agreed to within 2% of the measured values. Exit doses computed by XiO Convolution, XiO Superposition, Eclipse AXB, and Monaco MC agreed with the IC measured doses to within 2%‐3%. Meanwhile, Eclipse PBC and Eclipse AAA computed exit doses were higher than the IC measured doses by up to 5.3% and 4.8%, respectively. Both algorithms assume that full backscatter exists even at the exit level, leading to an overestimation of exit doses. Despite good agreements at the central axis for Eclipse AXB and Monaco MC, 1D relative comparisons showed profiles mismatched at depths beyond 11.5 cm. Overall, the 2D absolute gamma (3%/3 mm) pass rates were better for Monaco MC, while Eclipse AXB failed mostly at the outer 20% of the field area. The findings of this study serve as a useful baseline for the implementation of entrance and exit in vivo dosimetry in clinical departments utilizing any of these six common TPS algorithms for reference comparison. PACS numbers: 87.55.‐x, 87.55.D‐, 87.55.N‐, 87.53.Bn PMID:24892349

  17. Tracing the indirect societal impacts of biomedical research: development and piloting of a technique based on citations.

    PubMed

    Jones, Teresa H; Hanney, Steve

    There is growing interest in assessing the societal impacts of research such as informing health policies and clinical practice, and contributing to improved health. Bibliometric approaches have long been used to assess knowledge outputs, but can they also help evaluate societal impacts? We aimed to see how far the societal impacts could be traced by identifying key research articles in the psychiatry/neuroscience area and exploring their societal impact through analysing several generations of citing papers. Informed by a literature review of citation categorisation, we developed a prototype template to qualitatively assess a reference's importance to the citing paper and tested it on 96 papers. We refined the template for a pilot study to assess the importance of citations, including self-cites, to four key research articles. We then similarly assessed citations to those citing papers for which the key article was Central i.e. it was very important to the message of the citing article. We applied a filter of three or more citation occasions in order to focus on the citing articles where the reference was most likely to be Central. We found the reference was Central for 4.4 % of citing research articles overall and ten times more frequently if the article contained three or more citation occasions. We created a citation stream of influence for each key paper across up to five generations of citations. We searched the Web of Science for citations to all Central papers and identified societal impacts, including international clinical guidelines citing papers across the generations.

  18. Accurate label-free 3-part leukocyte recognition with single cell lens-free imaging flow cytometry.

    PubMed

    Li, Yuqian; Cornelis, Bruno; Dusa, Alexandra; Vanmeerbeeck, Geert; Vercruysse, Dries; Sohn, Erik; Blaszkiewicz, Kamil; Prodanov, Dimiter; Schelkens, Peter; Lagae, Liesbet

    2018-05-01

    Three-part white blood cell differentials which are key to routine blood workups are typically performed in centralized laboratories on conventional hematology analyzers operated by highly trained staff. With the trend of developing miniaturized blood analysis tool for point-of-need in order to accelerate turnaround times and move routine blood testing away from centralized facilities on the rise, our group has developed a highly miniaturized holographic imaging system for generating lens-free images of white blood cells in suspension. Analysis and classification of its output data, constitutes the final crucial step ensuring appropriate accuracy of the system. In this work, we implement reference holographic images of single white blood cells in suspension, in order to establish an accurate ground truth to increase classification accuracy. We also automate the entire workflow for analyzing the output and demonstrate clear improvement in the accuracy of the 3-part classification. High-dimensional optical and morphological features are extracted from reconstructed digital holograms of single cells using the ground-truth images and advanced machine learning algorithms are investigated and implemented to obtain 99% classification accuracy. Representative features of the three white blood cell subtypes are selected and give comparable results, with a focus on rapid cell recognition and decreased computational cost. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. [Process of institutional child guidance counseling reflected by the Central Continuing Education of the Federal Conference for Child Guidance Counseling].

    PubMed

    Pfeifer, W K

    2000-12-01

    The Bundeskonferenz für Erziehungsberatung (bke) is the federation for child guidance and family-counseling in Germany. Members are the working groups for child guidance and family-counseling of the Länder, where the employees of the child guidance are organized. The federation was founded in 1962. It is sponsored by the Federal Ministry for Family, Seniors, Women and Youth. Further education for professional youth workers is central mission of bke. The constitution of the federation lais down these contents. Every autumn the bke publishes the program for further education for the following year in a brochure called Zentrale Weiterbildung--the program for child guidance, family counseling and youth counseling. A special Kommission Zentrale Weiterbildung acquires the contents of the program for further education und selects the referents. Since 1968 the Zentrale Weiterbildung of Bundeskonferenz für Erziehungsberatung offers events for professional youth workers in child guidance, family counseling. The program for further education contributes the quality of the institution of child guidance. After a time with above average use of the program for further education with therapeutical focal point, the orientation of the program changes to child and youth services. A constant number of counselors use the program. Beside the change of contents there was a change to effectiveness of contents and a reduction of participants.

  20. Pick disease

    MedlinePlus

    ... Frontotemporal dementia; FTD; Arnold Pick disease; 3R tauopathy Images Central nervous system and peripheral nervous system References Bang J, Spina S, Miller BL. Frontotemporal dementia. Lancet . 2015;386( ...

  1. An analysis of methods for gravity determination and their utilization for the calculation of geopotential numbers in the Slovak national levelling network

    NASA Astrophysics Data System (ADS)

    Majkráková, Miroslava; Papčo, Juraj; Zahorec, Pavol; Droščák, Branislav; Mikuška, Ján; Marušiak, Ivan

    2016-09-01

    The vertical reference system in the Slovak Republic is realized by the National Levelling Network (NLN). The normal heights according to Molodensky have been introduced as reference heights in the NLN in 1957. Since then, the gravity correction, which is necessary to determine the reference heights in the NLN, has been obtained by an interpolation either from the simple or complete Bouguer anomalies. We refer to this method as the "original". Currently, the method based on geopotential numbers is the preferred way to unify the European levelling networks. The core of this article is an analysis of different ways to the gravity determination and their application for the calculation of geopotential numbers at the points of the NLN. The first method is based on the calculation of gravity at levelling points from the interpolated values of the complete Bouguer anomaly using the CBA2G_SK software. The second method is based on the global geopotential model EGM2008 improved by the Residual Terrain Model (RTM) approach. The calculated gravity is used to determine the normal heights according to Molodensky along parts of the levelling lines around the EVRF2007 datum point EH-V. Pitelová (UELN-1905325) and the levelling line of the 2nd order NLN to Kráľova hoľa Mountain (the highest point measured by levelling). The results from our analysis illustrate that the method based on the interpolated value of gravity is a better method for gravity determination when we do not know the measured gravity. It was shown that this method is suitable for the determination of geopotential numbers and reference heights in the Slovak national levelling network at the points in which the gravity is not observed directly. We also demonstrated the necessity of using the precise RTM for the refinement of the results derived solely from the EGM2008.

  2. Modulation of GCR in Various Types of Helispheric Magnetic Field

    NASA Astrophysics Data System (ADS)

    Kobylinski, Z.; Bochorishvili, T.

    We make an attempt to compare the modulation of galactic cosmic rays (GCR) as the result of various assumptions referred to heliospheric magnetic field (HMF). The steady state version of 3D Parker cosmic ray transport equation (TPE), with drift included, is solved num erically in the spherically symmetric heliosphere. We take into account four cases of the possible magnetic field configuration: standard Parker HMF, Parker field with modifications in polar direction done by Jokippi and K ta (2) and Smith ando Bieber (3) , Fisk type of field (4). In the last one we assume the existence north and south polar coronal holes in the inner corona with central point inclined from the rotation of the Sun. At the polar regions of the heliosphere the isotropic diffusion of GCR is assumed. The results of calculation s will be discussed in detail. The (4) model more reduces an acces s of galactic particles from polar direction into solar system than others.

  3. Functional magnetic resonance imaging study of Piaget's conservation-of-number task in preschool and school-age children: a neo-Piagetian approach.

    PubMed

    Houdé, Olivier; Pineau, Arlette; Leroux, Gaëlle; Poirel, Nicolas; Perchey, Guy; Lanoë, Céline; Lubin, Amélie; Turbelin, Marie-Renée; Rossi, Sandrine; Simon, Grégory; Delcroix, Nicolas; Lamberton, Franck; Vigneau, Mathieu; Wisniewski, Gabriel; Vicet, Jean-René; Mazoyer, Bernard

    2011-11-01

    Jean Piaget's theory is a central reference point in the study of logico-mathematical development in children. One of the most famous Piagetian tasks is number conservation. Failures and successes in this task reveal two fundamental stages in children's thinking and judgment, shifting at approximately 7 years of age from visuospatial intuition to number conservation. In the current study, preschool children (nonconservers, 5-6 years of age) and school-age children (conservers, 9-10 years of age) were presented with Piaget's conservation-of-number task and monitored by functional magnetic resonance imaging (fMRI). The cognitive change allowing children to access conservation was shown to be related to the neural contribution of a bilateral parietofrontal network involved in numerical and executive functions. These fMRI results highlight how the behavioral and cognitive stages Piaget formulated during the 20th century manifest in the brain with age. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. The Gravity Probe B Experiment

    NASA Technical Reports Server (NTRS)

    Kolodziejczak, Jeffrey

    2008-01-01

    This presentation briefly describes the Gravity Probe B (GP-B) Experiment which is designed to measure parts of Einstein's general theory of relativity by monitoring gyroscope orientation relative to a distant guide star. To measure the miniscule angles predicted by Einstein's theory, it was necessary to build near-perfect gyroscopes that were approximately 50 million times more precise than the best navigational gyroscopes. A telescope mounted along the central axis of the dewar and spacecraft provided the experiment's pointing reference to a guide star. The telescope's image divide precisely split the star's beam into x-axis and y-axis components whose brightness could be compared. GP-B's 650-gallon dewar, kept the science instrument inside the probe at a cryogenic temperature for 17.3 months and also provided the thruster propellant for precision attitude and translation control. Built around the dewar, the GP-B spacecraft was a total-integrated system, comprising both the space vehicle and payload, dedicated as a single entity to experimentally testing predictions of Einstein's theory.

  5. Breakup and then makeup: a predictive model of how cilia self-regulate hardness for posture control.

    PubMed

    Bandyopadhyay, Promode R; Hansen, Joshua C

    2013-01-01

    Functioning as sensors and propulsors, cilia are evolutionarily conserved organelles having a highly organized internal structure. How a paramecium's cilium produces off-propulsion-plane curvature during its return stroke for symmetry breaking and drag reduction is not known. We explain these cilium deformations by developing a torsional pendulum model of beat frequency dependence on viscosity and an olivo-cerebellar model of self-regulation of posture control. The phase dependence of cilia torsion is determined, and a bio-physical model of hardness control with predictive features is offered. Crossbridge links between the central microtubule pair harden the cilium during the power stroke; this stroke's end is a critical phase during which ATP molecules soften the crossbridge-microtubule attachment at the cilium inflection point where torsion is at its maximum. A precipitous reduction in hardness ensues, signaling the start of ATP hydrolysis that re-hardens the cilium. The cilium attractor basin could be used as reference for perturbation sensing.

  6. The long tail of a demon drug: The 'bath salts' risk environment.

    PubMed

    Elliott, Luther; Benoit, Ellen; Campos, Stephanie; Dunlap, Eloise

    2018-01-01

    Using the case of synthetic cathinones (commonly referred to as 'bath salts' in the US context), this paper analyses structural factors surrounding novel psychoactive substances (NPS) as contributing to the unique risk environment surrounding their use. Drawing on interviews with 39 people who use bath salts from four U.S. cities and analysis of the infrastructural, social, economic, and policy contexts, we document the unique harms related to changing contexts for illicit drug regulation, manufacture, and consumption. Findings suggest that NPS and designer drug markets, which are highly reliant upon the internet, share characteristics of the entertainment industry which has come to rely more heavily upon profits derived from the 'long tail' of myriad lesser-known products and the diminished centrality of 'superstars' and 'hits'. Findings point toward increased theoretical and policy attention to changing drug market structures, more rigorous evaluations of drug 'analogues' legislation and greater involvement with NPS education and testing by harm reduction agencies. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Biochemical characterization of predicted Precambrian RuBisCO

    PubMed Central

    Shih, Patrick M.; Occhialini, Alessandro; Cameron, Jeffrey C.; Andralojc, P John; Parry, Martin A. J.; Kerfeld, Cheryl A.

    2016-01-01

    The antiquity and global abundance of the enzyme, RuBisCO, attests to the crucial and longstanding role it has played in the biogeochemical cycles of Earth over billions of years. The counterproductive oxygenase activity of RuBisCO has persisted over billions of years of evolution, despite its competition with the carboxylase activity necessary for carbon fixation, yet hypotheses regarding the selective pressures governing RuBisCO evolution have been limited to speculation. Here we report the resurrection and biochemical characterization of ancestral RuBisCOs, dating back to over one billion years ago (Gyr ago). Our findings provide an ancient point of reference revealing divergent evolutionary paths taken by eukaryotic homologues towards improved specificity for CO2, versus the evolutionary emphasis on increased rates of carboxylation observed in bacterial homologues. Consistent with these distinctions, in vivo analysis reveals the propensity of ancestral RuBisCO to be encapsulated into modern-day carboxysomes, bacterial organelles central to the cyanobacterial CO2 concentrating mechanism. PMID:26790750

  8. Biochemical characterization of predicted Precambrian RuBisCO.

    PubMed

    Shih, Patrick M; Occhialini, Alessandro; Cameron, Jeffrey C; Andralojc, P John; Parry, Martin A J; Kerfeld, Cheryl A

    2016-01-21

    The antiquity and global abundance of the enzyme, RuBisCO, attests to the crucial and longstanding role it has played in the biogeochemical cycles of Earth over billions of years. The counterproductive oxygenase activity of RuBisCO has persisted over billions of years of evolution, despite its competition with the carboxylase activity necessary for carbon fixation, yet hypotheses regarding the selective pressures governing RuBisCO evolution have been limited to speculation. Here we report the resurrection and biochemical characterization of ancestral RuBisCOs, dating back to over one billion years ago (Gyr ago). Our findings provide an ancient point of reference revealing divergent evolutionary paths taken by eukaryotic homologues towards improved specificity for CO2, versus the evolutionary emphasis on increased rates of carboxylation observed in bacterial homologues. Consistent with these distinctions, in vivo analysis reveals the propensity of ancestral RuBisCO to be encapsulated into modern-day carboxysomes, bacterial organelles central to the cyanobacterial CO2 concentrating mechanism.

  9. Breakup and then makeup: a predictive model of how cilia self-regulate hardness for posture control

    NASA Astrophysics Data System (ADS)

    Bandyopadhyay, Promode R.; Hansen, Joshua C.

    2013-06-01

    Functioning as sensors and propulsors, cilia are evolutionarily conserved organelles having a highly organized internal structure. How a paramecium's cilium produces off-propulsion-plane curvature during its return stroke for symmetry breaking and drag reduction is not known. We explain these cilium deformations by developing a torsional pendulum model of beat frequency dependence on viscosity and an olivo-cerebellar model of self-regulation of posture control. The phase dependence of cilia torsion is determined, and a bio-physical model of hardness control with predictive features is offered. Crossbridge links between the central microtubule pair harden the cilium during the power stroke; this stroke's end is a critical phase during which ATP molecules soften the crossbridge-microtubule attachment at the cilium inflection point where torsion is at its maximum. A precipitous reduction in hardness ensues, signaling the start of ATP hydrolysis that re-hardens the cilium. The cilium attractor basin could be used as reference for perturbation sensing.

  10. Cube - an online tool for comparison and contrasting of protein sequences.

    PubMed

    Zhang, Zong Hong; Khoo, Aik Aun; Mihalek, Ivana

    2013-01-01

    When comparing sequences of similar proteins, two kinds of questions can be asked, and the related two kinds of inference made. First, one may ask to what degree they are similar, and then, how they differ. In the first case one may tentatively conclude that the conserved elements common to all sequences are of central and common importance to the protein's function. In the latter case the regions of specialization may be discriminative of the function or binding partners across subfamilies of related proteins. Experimental efforts - mutagenesis or pharmacological intervention - can then be pointed in either direction, depending on the context of the study. Cube simplifies this process for users that already have their favorite sets of sequences, and helps them collate the information by visualization of the conservation and specialization scores on the sequence and on the structure, and by spreadsheet tabulation. All information can be visualized on the spot, or downloaded for reference and later inspection. http://eopsf.org/cube.

  11. Induction and function of virus-specific CD4+ T cell responses

    PubMed Central

    Whitmire, Jason K.

    2010-01-01

    CD4+ T cells -- often referred to as T-helper cells -- play a central role in immune defense and pathogenesis. Virus infections and vaccines stimulate and expand populations of antigen-specific CD4+ T cells in mice and in man. These virus-specific CD4+ T cells are extremely important in antiviral protection: deficiencies in CD4+ T cells are associated with virus reactivation, generalized susceptibility to opportunistic infections, and poor vaccine efficacy. As described below, CD4+ T cells influence effector and memory CD8+ T cell responses, humoral immunity, and the antimicrobial activity of macrophages and are involved in recruiting cells to sites of infection. This review summarizes a few key points about the dynamics of the CD4+ T cell response to virus infection, the positive role of pro-inflammatory cytokines in the differentiation of virus-specific CD4+ T cells, and new areas of investigation to improve vaccines against virus infection. PMID:21236461

  12. The emergence of care facilities in Thailand for older German-speaking people: structural backgrounds and facility operators as transnational actors.

    PubMed

    Bender, Désirée; Hollstein, Tina; Schweppe, Cornelia

    2017-12-01

    This paper presents findings from an ethnographic study of old age care facilities for German-speaking people in Thailand. It analyses the conditions and processes behind the development and specific designs of such facilities. It first looks at the intertwinement, at the socio-structural level, of different transborder developments in which the facilities' emergence is embedded. Second, it analyses the processes that accompany the emergence, development and organisation of these facilities at the local level. In this regard, it points out the central role of the facility operators as transnational actors who mediate between different frames of reference and groups of actors involved in these facilities. It concludes that the processes of mediation and intertwining are an important and distinctive feature of the emergence of these facilities, necessitated by the fact that, although the facilities are located in Thailand, their 'markets' are in the German-speaking countries of their target groups.

  13. Breakup and then makeup: a predictive model of how cilia self-regulate hardness for posture control

    PubMed Central

    Bandyopadhyay, Promode R.; Hansen, Joshua C.

    2013-01-01

    Functioning as sensors and propulsors, cilia are evolutionarily conserved organelles having a highly organized internal structure. How a paramecium's cilium produces off-propulsion-plane curvature during its return stroke for symmetry breaking and drag reduction is not known. We explain these cilium deformations by developing a torsional pendulum model of beat frequency dependence on viscosity and an olivo-cerebellar model of self-regulation of posture control. The phase dependence of cilia torsion is determined, and a bio-physical model of hardness control with predictive features is offered. Crossbridge links between the central microtubule pair harden the cilium during the power stroke; this stroke's end is a critical phase during which ATP molecules soften the crossbridge-microtubule attachment at the cilium inflection point where torsion is at its maximum. A precipitous reduction in hardness ensues, signaling the start of ATP hydrolysis that re-hardens the cilium. The cilium attractor basin could be used as reference for perturbation sensing. PMID:23739771

  14. Assessment of DPOAE test-retest difference curves via hierarchical Gaussian processes.

    PubMed

    Bao, Junshu; Hanson, Timothy; McMillan, Garnett P; Knight, Kristin

    2017-03-01

    Distortion product otoacoustic emissions (DPOAE) testing is a promising alternative to behavioral hearing tests and auditory brainstem response testing of pediatric cancer patients. The central goal of this study is to assess whether significant changes in the DPOAE frequency/emissions curve (DP-gram) occur in pediatric patients in a test-retest scenario. This is accomplished through the construction of normal reference charts, or credible regions, that DP-gram differences lie in, as well as contour probabilities that measure how abnormal (or in a certain sense rare) a test-retest difference is. A challenge is that the data were collected over varying frequencies, at different time points from baseline, and on possibly one or both ears. A hierarchical structural equation Gaussian process model is proposed to handle the different sources of correlation in the emissions measurements, wherein both subject-specific random effects and variance components governing the smoothness and variability of each child's Gaussian process are coupled together. © 2016, The International Biometric Society.

  15. Cryo-EM structure of Hepatitis C virus IRES bound to the human ribosome at 3.9-Å resolution

    NASA Astrophysics Data System (ADS)

    Quade, Nick; Boehringer, Daniel; Leibundgut, Marc; van den Heuvel, Joop; Ban, Nenad

    2015-07-01

    Hepatitis C virus (HCV), a widespread human pathogen, is dependent on a highly structured 5'-untranslated region of its mRNA, referred to as internal ribosome entry site (IRES), for the translation of all of its proteins. The HCV IRES initiates translation by directly binding to the small ribosomal subunit (40S), circumventing the need for many eukaryotic translation initiation factors required for mRNA scanning. Here we present the cryo-EM structure of the human 40S ribosomal subunit in complex with the HCV IRES at 3.9 Å resolution, determined by focused refinement of an 80S ribosome-HCV IRES complex. The structure reveals the molecular details of the interactions between the IRES and the 40S, showing that expansion segment 7 (ES7) of the 18S rRNA acts as a central anchor point for the HCV IRES. The structural data rationalizes previous biochemical and genetic evidence regarding the initiation mechanism of the HCV and other related IRESs.

  16. A Two-Dimensional Linear Bicharacteristic FDTD Method

    NASA Technical Reports Server (NTRS)

    Beggs, John H.

    2002-01-01

    The linear bicharacteristic scheme (LBS) was originally developed to improve unsteady solutions in computational acoustics and aeroacoustics. The LBS has previously been extended to treat lossy materials for one-dimensional problems. It is a classical leapfrog algorithm, but is combined with upwind bias in the spatial derivatives. This approach preserves the time-reversibility of the leapfrog algorithm, which results in no dissipation, and it permits more flexibility by the ability to adopt a characteristic based method. The use of characteristic variables allows the LBS to include the Perfectly Matched Layer boundary condition with no added storage or complexity. The LBS offers a central storage approach with lower dispersion than the Yee algorithm, plus it generalizes much easier to nonuniform grids. It has previously been applied to two and three-dimensional free-space electromagnetic propagation and scattering problems. This paper extends the LBS to the two-dimensional case. Results are presented for point source radiation problems, and the FDTD algorithm is chosen as a convenient reference for comparison.

  17. The South Central Superpave Center: Report of Activities

    DOT National Transportation Integrated Search

    1998-12-01

    The planning of the South Central Superpave Center (SCSC) began in mid-1994. The Center hired its first staff in early 1995 and was fully staffed by June 1995, at which point it became fully operational. This report describes SCSC activities that too...

  18. [Evaluation of physical fitness levels in children and adolescents: establishing percentile charts for the central region of Peru].

    PubMed

    Bustamante, Alcibíades; Beunen, Gastón; Maia, José

    2012-06-01

    Construct percentile charts and physical fitness (PF) reference values stratified by age and sex of children and adolescents from Peru's central region. The sample was comprised of 7,843 subjects (4,155 females and 3,688 males) between the ages of 6 to 17 years old. Physical fitness was assessed using six tests developed by EUROFIT, FITNESSGRAM and AAPHERD. Percentile charts were developed separately for males and females using the LMS method calculated with LMSchartmaker software. Results. Males showed higher PF values with the exception of flexibility; a clear increase in PF with increasing age was verified. Inter-individual variability in both sexes is substantial. Charts and specific reference values by age and sex may be used for the assessment and interpretation of children's and adolescents' PF levels in Peru's central region. These findings may be of help to educators, public health professionals, parents, and policy-makers when assessing schools' physical education programs.

  19. Global reference frame: Intercomparison of results (SLR, VLBI and GPS)

    NASA Technical Reports Server (NTRS)

    Ma, Chopo; Watkins, Michael M.; Heflin, M.

    1994-01-01

    The terrestrial reference frame (TRF) is realized by a set of positions and velocities derived from a combination of the three space geodetic techniques, SLR, VLBI and GPS. The standard International TRF is constructed by the International Earth Rotation Service in such a way that it is stable with time and the addition of new data. An adopted model for overall plate motion, NUVEL-1 NNR, defines the conceptual reference frame in which all the plates are moving. In addition to the measurements made between reference points within the space geodetic instruments, it is essential to have accurate, documented eccentricity measurements from the instrument reference points to ground monuments. Proper local surveys between the set of ground monuments at a site are also critical for the use of the space geodetic results. Eccentricities and local surveys are, in fact, the most common and vexing sources of error in the use of the TRF for such activities as collocation and intercomparison.

  20. Efficient High Order Central Schemes for Multi-Dimensional Hamilton-Jacobi Equations: Talk Slides

    NASA Technical Reports Server (NTRS)

    Bryson, Steve; Levy, Doron; Biegel, Brian R. (Technical Monitor)

    2002-01-01

    This viewgraph presentation presents information on the attempt to produce high-order, efficient, central methods that scale well to high dimension. The central philosophy is that the equations should evolve to the point where the data is smooth. This is accomplished by a cyclic pattern of reconstruction, evolution, and re-projection. One dimensional and two dimensional representational methods are detailed, as well.

Top