Sample records for centrifugal force gradient

  1. Reduction of centrifugation force in discontinuous percoll gradients increases in vitro fertilization rates without reducing bovine sperm recovery.

    PubMed

    Guimarães, A C G; Leivas, F G; Santos, F W; Schwengber, E B; Giotto, A B; Machado, C I U; Gonçalves, C G M; Folchini, N P; Brum, D S

    2014-05-01

    The objective of this study was to determine the effect of different centrifugation forces in bovine sperm separation by discontinuous Percoll gradients for in vitro fertilization IVF. The semen samples from each bull were pooled or each bull were centrifuged separately and centrifuged in discontinuous Percoll gradients (30, 60 and 90%) at different forces: F1 (9000×g), F2 (6500×g), F3 (4500×g) and F4 (2200×g), according experiment. The sperm samples were evaluated to determine the concentration, motility, vigor, morphology, reactive oxygen species (ROS), integrity of the plasma membrane, lipid peroxidation, antioxidants and embryo development were also evaluated. No difference was observed in the concentration of sperm submitted to different centrifugation forces. The total percentage of motile sperm was increased after centrifugation at F3 and F4, and the ROS production at F1 was greater than the other forces. When the bulls semen were processed individually, no significant differences were observed for the sperm quality parameters between F1 and F4, including lipid peroxidation, antioxidants, cleavage rate and average time to the first cleavage. This work demonstrated for the first time that centrifugation at 2200×g enhanced the sperm penetration and fertilization rates without reducing sperm recovery compared to the typical centrifugation force (9000×g) currently used by the commercial bovine IVF industry. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Transport modes during crystal growth in a centrifuge

    NASA Technical Reports Server (NTRS)

    Arnold, William A.; Wilcox, William R.; Carlson, Frederick; Chait, Arnon; Regel', Liia L.

    1992-01-01

    Flow modes arising under average acceleration in centrifugal crystal growth, the gradient of acceleration, and the Coriolis force are investigated using a fully nonlinear three-dimensional numerical model for a centrifugal crystal growth experiment. The analysis focuses on an examination of the quasi-steady state flow modes. The importance of the gradient acceleration is determined by the value of a new nondimensional number, Ad.

  3. Enhancing Centrifugal Separation With Electrophoresis

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1986-01-01

    Separation of biological cells by coil-planet centrifuge enhanced by electrophoresis. By itself, coil-planet centrifuge offers relatively gentle method of separating cells under low centrifugal force in physiological medium that keeps cells alive. With addition of voltage gradient to separation column of centrifuge, separation still gentle but faster and more complete. Since separation apparatus contains no rotary seal, probability of leakage, contamination, corrosion, and short circuits reduced.

  4. Secondary currents in a curved, stratified, estuarine channel

    USGS Publications Warehouse

    Lacy, J.R.; Monismith, Stephen G.

    2001-01-01

    This paper presents a study of secondary circulation in a curved stratified channel in northern San Francisco Bay over a 12.5-hour tidal cycle. Secondary currents were strong at times (varying by up to 35 cm/s from top to bottom) but relatively transient, as the balance between centrifugal and lateral baroclinic forcing changed over time. The short travel time around the bend did not allow a steady state balance to develop between centrifugal and lateral baroclinic forcing. During the flood tide the confluence of two streams with different velocities produced a strong lateral gradient in streamwise velocity. As a result, lateral advection was a significant term in the streamwise momentum balance, having the same order of magnitude as the barotropic and baroclinic pressure gradients, and the frictional terms. During the first part of the ebb, secondary currents were induced by lateral baroclinic forcing. The direction of the secondary circulation reversed later in the ebb, as the baroclinic forcing became weaker than the centrifugal acceleration. The gradient Richardson number showed that stratification was stable over most of the tidal cycle, decreasing the importance of friction and allowing secondary currents to persist. Copyright 2001 by the American Geophysical Union.

  5. The influence of centrifugal forces on the B field structure of an axially symmetric equilibrium magnetosphere

    NASA Technical Reports Server (NTRS)

    Ye, Gang; Voigt, Gerd-Hannes

    1989-01-01

    A model is presented of an axially symmetric pole-on magnetosphere in MHD force balance, in which both plasma thermal pressure gradients and centrifugal force are taken into account. Assuming that planetary rotation leads to differentially rotating magnetotail field lines, the deformation of magnetotail field lines under the influence of both thermal plasma pressure and centrifugal forces was calculated. Analytic solutions to the Grad-Shafranov equation are presented, which include the centrifugal force term. It is shown that the nonrotational magnetosphere with hot thermal plasma leads to a field configuration without a toroidal B(phi) component and without field-aligned Birkeland currents. The other extreme, a rapidly rotating magnetosphere with cold plasma, leads to a configuration in which plasma must be confined within a thin disk in a plane where the radial magnetic field component B(r) vanishes locally.

  6. Ballooning instabilities in tokamaks with sheared toroidal flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waelbroeck, F.L.; Chen, L.

    1990-11-01

    The stability of ballooning modes in the presence of sheared toroidal flows is investigated. The eigenmodes are shown to be related by a Fourier transformation to the non-exponentially growing Floquet solutions found by Cooper. It is further shown that the problem cannot be reduced further than to a two dimensional partial differential equation. Next, the generalized ballooning equation is solved analytically for a circular tokamak equilibrium with sonic flows, but with a small rotation shear compared to the sound speed. With this ordering, the centrifugal forces are comparable to the pressure gradient forces driving the instability, but coupling of themore » mode with the sound wave is avoided. A new stability criterion is derived which explicitly demonstrates that flow shear is stabilizing at constant centrifugal force gradient. 34 refs.« less

  7. Materials processing in a centrifuge - Numerical modeling of macrogravity effects

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Downey, J. P.; Jones, J. C.; Curreri, P. A.

    1992-01-01

    The fluid mechanics associated with crystal growth processes on a centrifuge is investigated. A simple scaling analysis is used to examine the relative magnitudes of the forces acting on the system and good agreement is obtained with previous studies. A two-dimensional model of crystal growth on a centrifuge is proposed and calculations are undertaken to help in understanding the fundamental transport processes within the crystal growth cell. Results from three-dimensional calculations of actual centrifuge-based crystal growth systems are presented both for the thermodynamically stable and unstable configurations. The calculations show the existence of flow bifurcations in certain configurations but not in all instances. The numerical simulations also show that the centrifugal force is the dominant stabilizing force on fluid convection in the stable configuration. The stabilizing influence of the Coriolis force is found to be only secondary in nature. No significant impact of gravity gradient is found in the calculations. Simulations of unstable configurations show that the Coriolis force has a stabilizing influence on fluid motion by delaying the onset of unsteady convection. Detailed flow and thermal field characteristics are presented for all the different cases that are simulated.

  8. Microfluidic size separation of cells and particles using a swinging bucket centrifuge.

    PubMed

    Yeo, Joo Chuan; Wang, Zhiping; Lim, Chwee Teck

    2015-09-01

    Biomolecular separation is crucial for downstream analysis. Separation technique mainly relies on centrifugal sedimentation. However, minuscule sample volume separation and extraction is difficult with conventional centrifuge. Furthermore, conventional centrifuge requires density gradient centrifugation which is laborious and time-consuming. To overcome this challenge, we present a novel size-selective bioparticles separation microfluidic chip on a swinging bucket minifuge. Size separation is achieved using passive pressure driven centrifugal fluid flows coupled with centrifugal force acting on the particles within the microfluidic chip. By adopting centrifugal microfluidics on a swinging bucket rotor, we achieved over 95% efficiency in separating mixed 20 μm and 2 μm colloidal dispersions from its liquid medium. Furthermore, by manipulating the hydrodynamic resistance, we performed size separation of mixed microbeads, achieving size efficiency of up to 90%. To further validate our device utility, we loaded spiked whole blood with MCF-7 cells into our microfluidic device and subjected it to centrifugal force for a mere duration of 10 s, thereby achieving a separation efficiency of over 75%. Overall, our centrifugal microfluidic device enables extremely rapid and label-free enrichment of different sized cells and particles with high efficiency.

  9. Microfluidic size separation of cells and particles using a swinging bucket centrifuge

    PubMed Central

    Yeo, Joo Chuan; Wang, Zhiping; Lim, Chwee Teck

    2015-01-01

    Biomolecular separation is crucial for downstream analysis. Separation technique mainly relies on centrifugal sedimentation. However, minuscule sample volume separation and extraction is difficult with conventional centrifuge. Furthermore, conventional centrifuge requires density gradient centrifugation which is laborious and time-consuming. To overcome this challenge, we present a novel size-selective bioparticles separation microfluidic chip on a swinging bucket minifuge. Size separation is achieved using passive pressure driven centrifugal fluid flows coupled with centrifugal force acting on the particles within the microfluidic chip. By adopting centrifugal microfluidics on a swinging bucket rotor, we achieved over 95% efficiency in separating mixed 20 μm and 2 μm colloidal dispersions from its liquid medium. Furthermore, by manipulating the hydrodynamic resistance, we performed size separation of mixed microbeads, achieving size efficiency of up to 90%. To further validate our device utility, we loaded spiked whole blood with MCF-7 cells into our microfluidic device and subjected it to centrifugal force for a mere duration of 10 s, thereby achieving a separation efficiency of over 75%. Overall, our centrifugal microfluidic device enables extremely rapid and label-free enrichment of different sized cells and particles with high efficiency. PMID:26487900

  10. Squat exercise biomechanics during short-radius centrifugation.

    PubMed

    Duda, Kevin R; Jarchow, Thomas; Young, Laurence R

    2012-02-01

    Centrifuge-induced artificial gravity (AG) with exercise is a promising comprehensive countermeasure against the physiological de-conditioning that results from exposure to weightlessness. However, body movements onboard a rotating centrifuge are affected by both the gravity gradient and Coriolis accelerations. The effect of centrifugation on squat exercise biomechanics was investigated, and differences between AG and upright squat biomechanics were quantified. There were 28 subjects (16 male) who participated in two separate experiments. Knee position, foot reaction forces, and motion sickness were recorded during the squats in a 1-G field while standing upright and while supine on a horizontally rotating 2 m radius centrifuge at 0, 23, or 30 rpm. No participants terminated the experiment due to motion sickness symptoms. Total mediolateral knee deflection increased by 1.0 to 2.0 cm during centrifugation, and did not result in any injuries. There was no evidence of an increased mediolateral knee travel "after-effect" during postrotation supine squats. Peak foot reaction forces increased with rotation rate up to approximately 200% bodyweight (iRED on ISS provides approximately 210% bodyweight resistance). The ratio of left-to-right foot force throughout the squat cycle on the centrifuge was nonconstant and approximately sinusoidal. Total foot reaction force versus knee flexion-extension angles differed between upright and AG squats due to centripetal acceleration on the centrifuge. A brief exercise protocol during centrifugation can be safely completed without significant after-effects in mediolateral knee position or motion sickness. Several recommendations are made for the design of future centrifuge-based exercise protocols for in-space applications.

  11. Directly observed reversible shape changes and hemoglobin stratification during centrifugation of human and Amphiuma red blood cells.

    PubMed

    Hoffman, Joseph F; Inoué, Shinya

    2006-02-21

    This paper describes changes that occur in human and Amphiuma red blood cells observed during centrifugation with a special microscope. Dilute suspensions of cells were layered, in a centrifuge chamber, above an osmotically matched dense solution, containing Nycodenz, Ficoll, or Percoll (Pharmacia) that formed a density gradient that allowed the cells to slowly settle to an equilibrium position. Biconcave human red blood cells moved downward at low forces with minimum wobble. The cells oriented vertically when the force field was increased and Hb sedimented as the lower part of each cell became bulged and assumed a "bag-like" shape. The upper centripetal portion of the cell became thinner and remained biconcave. These changes occurred rapidly and were completely reversible upon lowering the centrifugal force. Bag-shaped cells, upon touching red cells in rouleau, immediately reverted to biconcave disks as they flipped onto a stack. Amphiuma red cells displayed a different type of reversible stratification and deformation at high force fields. Here the cells became stretched, with the nucleus now moving centrifugally, the Hb moving centripetally, and the bottom of the cells becoming thinner and clear. Nevertheless, the distribution of the marginal bands at the cells' rim was unchanged. We conclude that centrifugation, per se, while changing a red cell's shape and the distribution of its intracellular constituents, does so in a completely reversible manner. Centrifugation of red cells harboring altered or missing structural elements could provide information on shape determinants that are still unexplained.

  12. Centrifugal techniques for measuring saturated hydraulic conductivity

    USGS Publications Warehouse

    Nimmo, John R.; Mello, Karen A.

    1991-01-01

    Centrifugal force is an alternative to large pressure gradients for the measurement of low values of saturated hydraulic conductivity (Ksat). With a head of water above a porous medium in a centrifuge bucket, both constant-head and falling-head measurements are practical at forces up to at least 1800 times normal gravity. Darcy's law applied to the known centrifugal potential leads to simple formulas for Ksat that are analogous to those used in the standard gravity-driven constant- and falling-head methods. Both centrifugal methods were tested on several fine-textured samples of soil and ceramic with Ksat between about 10−10 and 10−9 m/s. The results were compared to falling-head gravity measurements. The comparison shows most measurements agreeing to within 20% for a given sample, much of the variation probably resulting from run-to-run changes in sample structure. The falling-head centrifuge method proved to be especially simple in design and operation and was more accurate than the constant-head method. With modified apparatus, Ksat measurements less than 10−10 m/s should be attainable.

  13. Cardiovascular Responses of Snakes to Gravitational Gradients

    NASA Technical Reports Server (NTRS)

    Hsieh, Shi-Tong T.; Lillywhite, H. B.; Ballard, R. E.; Hargens, A. R.; Holton, Emily M. (Technical Monitor)

    1998-01-01

    Snakes are useful vertebrates for studies of gravitational adaptation, owing to their elongate body and behavioral diversification. Scansorial species have evolved specializations for regulating hemodynamics during exposure to gravitational stress, whereas, such adaptations are less well developed in aquatic and non-climbing species. We examined responses of the amphibious snake,\\italicize (Nerodia rhombifera), to increments of Gz (head-to-tail) acceleration force on both a short- and long-arm centrifuge (1.5 vs. 3.7 m radius, from the hub to tail end of snake). We recorded heart rate, dorsal aortic pressure, and carotid arterial blood flow during stepwise 0.25 G increments of Gz force (referenced at the tail) in conscious animals. The Benz tolerance of a snake was determined as the Gz level at which carotid blood flow ceased and was found to be significantly greater at the short- than long-arm centrifuge radius (1.57 Gz vs. 2.0 Gz, respectively; P=0.016). A similar pattern of response was demonstrated in semi-arboreal rat snakes,\\italicize{Elaphe obsoleta}, which are generally more tolerant of Gz force (2.6 Gz at 1.5m radius) than are water snakes. The tolerance differences of the two species reflected cardiovascular responses, which differed quantitatively but not qualitatively: heart rates increased while arterial pressure and blood flow decreased in response to increasing levels of Gz. Thus, in both species of snakes, a reduced gradient of Gz force (associated with greater centrifuge radius) significantly decreases the Gz level that can be tolerated.

  14. Numerical modeling of crystal growth on a centrifuge for unstable natural convection configurations

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Downey, J. P.; Curreri, P. A.; Jones, J. C.

    1993-01-01

    The fluid mechanics associated with crystal growth processes on centrifuges is modeled using 2D and 3D models. Two-dimensional calculations show that flow bifurcations exist in such crystal growth configurations where the ampoule is oriented in the same direction as the resultant gravity vector and a temperature gradient is imposed on the melt. A scaling analysis is formulated to predict the flow transition point from the natural convection dominated regime to the Coriolis force dominated regime. Results of 3D calculations are presented for two thermal configurations of the crystal growth cell: top heated and bottom heated with respect to the centrifugal acceleration. In the top heated configuration, a substantial reduction in the convection intensity within the melt can be attained by centrifuge operations, and close to steady diffusion-limited thermal conditions can be achieved over a narrow range of the imposed microgravity level. In the bottom heated configuration the Coriolis force has a stabilizing effect on fluid motion by delaying the onset of unsteady convection.

  15. Scientific uses and technical implementation of a variable gravity centrifuge on Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Johnson, C. C.; Hargens, A. R.

    1990-01-01

    The potential need and science requirements for a centrifuge to be designed and flown on Space Station Freedom are discussed, with a focus on a design concept for a centrifuge developed at NASA Ames. Applications identified for the centrifuge include fundamental studies in which gravity is a variable under experimental control, the need to provide a 1-g control, attempts to discover the threshold value of gravitation force for psychological response, and an effort to determine the effects of intermittent hypergravity. Science requirements specify the largest possible diameter at approximately 2.5 m, gravity levels ranging from 0.01 to 2 g, a nominal ramp-up rate of 0.01 g/sec, and life support for plants and animals. Ground-based studies using rats and squirrel monkeys on small-diameter centrifuges have demonstrated that animals can adapt to centrifugation at gravity gradients higher than those normally used in ground-based hypergravity studies.

  16. Stability of magnetohydrodynamic Dean Flow as applied to centrifugally confined plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassam, A.B.

    1999-10-01

    Dean Flow is the azimuthal flow of fluid between static concentric cylinders. In a magnetized plasma, there may also be radial stratification of the pressure. The ideal magnetohydrodynamic stability of such a flow in the presence of a strong axial magnetic field and an added radial gravitational force is examined. It is shown that both the Kelvin{endash}Helmholtz instability and pressure-gradient-driven interchanges can be stabilized if the flow is driven by a unidirectional external force and if the plasma annulus is sufficiently thin (large aspect ratio). These results find application in schemes using centrifugal confinement of plasma for fusion. {copyright} {italmore » 1999 American Institute of Physics.}« less

  17. Regimes of Coriolis-Centrifugal Convection

    NASA Astrophysics Data System (ADS)

    Horn, Susanne; Aurnou, Jonathan M.

    2018-05-01

    Centrifugal buoyancy affects all rotating turbulent convection phenomena, but is conventionally ignored in rotating convection studies. Here, we include centrifugal buoyancy to investigate what we call Coriolis-centrifugal convection (C3 ), characterizing two so far unexplored regimes, one where the flow is in quasicyclostrophic balance (QC regime) and another where the flow is in a triple balance between pressure gradient, Coriolis and centrifugal buoyancy forces (CC regime). The transition to centrifugally dominated dynamics occurs when the Froude number Fr equals the radius-to-height aspect ratio γ . Hence, turbulent convection experiments with small γ may encounter centrifugal effects at lower Fr than traditionally expected. Further, we show analytically that the direct effect of centrifugal buoyancy yields a reduction of the Nusselt number Nu. However, indirectly, it can cause a simultaneous increase of the viscous dissipation and thereby Nu through a change of the flow morphology. These direct and indirect effects yield a net Nu suppression in the CC regime and a net Nu enhancement in the QC regime. In addition, we demonstrate that C3 may provide a simplified, yet self-consistent, model system for tornadoes, hurricanes, and typhoons.

  18. Regimes of Coriolis-Centrifugal Convection.

    PubMed

    Horn, Susanne; Aurnou, Jonathan M

    2018-05-18

    Centrifugal buoyancy affects all rotating turbulent convection phenomena, but is conventionally ignored in rotating convection studies. Here, we include centrifugal buoyancy to investigate what we call Coriolis-centrifugal convection (C^{3}), characterizing two so far unexplored regimes, one where the flow is in quasicyclostrophic balance (QC regime) and another where the flow is in a triple balance between pressure gradient, Coriolis and centrifugal buoyancy forces (CC regime). The transition to centrifugally dominated dynamics occurs when the Froude number Fr equals the radius-to-height aspect ratio γ. Hence, turbulent convection experiments with small γ may encounter centrifugal effects at lower Fr than traditionally expected. Further, we show analytically that the direct effect of centrifugal buoyancy yields a reduction of the Nusselt number Nu. However, indirectly, it can cause a simultaneous increase of the viscous dissipation and thereby Nu through a change of the flow morphology. These direct and indirect effects yield a net Nu suppression in the CC regime and a net Nu enhancement in the QC regime. In addition, we demonstrate that C^{3} may provide a simplified, yet self-consistent, model system for tornadoes, hurricanes, and typhoons.

  19. CENTRIFUGAL SEPARATORS

    DOEpatents

    Skarstrom, C.

    1959-03-10

    A centrifugal separator is described for separating gaseous mixtures where the temperature gradients both longitudinally and radially of the centrifuge may be controlled effectively to produce a maximum separation of the process gases flowing through. Tbe invention provides for the balancing of increases and decreases in temperature in various zones of the centrifuge chamber as the result of compression and expansions respectively, of process gases and may be employed effectively both to neutralize harmful temperature gradients and to utilize beneficial temperaturc gradients within the centrifuge.

  20. Reducing the data: Analysis of the role of vascular geometry on blood flow patterns in curved vessels

    NASA Astrophysics Data System (ADS)

    Alastruey, Jordi; Siggers, Jennifer H.; Peiffer, Véronique; Doorly, Denis J.; Sherwin, Spencer J.

    2012-03-01

    Three-dimensional simulations of blood flow usually produce such large quantities of data that they are unlikely to be of clinical use unless methods are available to simplify our understanding of the flow dynamics. We present a new method to investigate the mechanisms by which vascular curvature and torsion affect blood flow, and we apply it to the steady-state flow in single bends, helices, double bends, and a rabbit thoracic aorta based on image data. By calculating forces and accelerations in an orthogonal coordinate system following the centreline of each vessel, we obtain the inertial forces (centrifugal, Coriolis, and torsional) explicitly, which directly depend on vascular curvature and torsion. We then analyse the individual roles of the inertial, pressure gradient, and viscous forces on the patterns of primary and secondary velocities, vortical structures, and wall stresses in each cross section. We also consider cross-sectional averages of the in-plane components of these forces, which can be thought of as reducing the dynamics of secondary flows onto the vessel centreline. At Reynolds numbers between 50 and 500, secondary motions in the directions of the local normals and binormals behave as two underdamped oscillators. These oscillate around the fully developed state and are coupled by torsional forces that break the symmetry of the flow. Secondary flows are driven by the centrifugal and torsional forces, and these are counterbalanced by the in-plane pressure gradients generated by the wall reaction. The viscous force primarily opposes the pressure gradient, rather than the inertial forces. In the axial direction, and depending on the secondary motion, the curvature-dependent Coriolis force can either enhance or oppose the bulk of the axial flow, and this shapes the velocity profile. For bends with little or no torsion, the Coriolis force tends to restore flow axisymmetry. The maximum circumferential and axial wall shear stresses along the centreline correlate well with the averaged in-plane pressure gradient and the radial displacement of the peak axial velocity, respectively. We conclude with a discussion of the physiological implications of these results.

  1. Physics of Artificial Gravity

    NASA Technical Reports Server (NTRS)

    Bukley, Angie; Paloski, William; Clement, Gilles

    2006-01-01

    This chapter discusses potential technologies for achieving artificial gravity in a space vehicle. We begin with a series of definitions and a general description of the rotational dynamics behind the forces ultimately exerted on the human body during centrifugation, such as gravity level, gravity gradient, and Coriolis force. Human factors considerations and comfort limits associated with a rotating environment are then discussed. Finally, engineering options for designing space vehicles with artificial gravity are presented.

  2. Effect of centrifugal fractionation protocols on quality and recovery rate of equine sperm.

    PubMed

    Edmond, A J; Brinsko, S P; Love, C C; Blanchard, T L; Teague, S R; Varner, D D

    2012-03-15

    Centrifugal fractionation of semen is commonly done to improve quality of human semen in assisted-reproduction laboratories, allowing sperm separation based on their isopycnic points. Sperm with morphologic abnormalities are often more buoyant, promoting their retention above defined density media, with structurally normal sperm passing through the media following centrifugation. Three experiments were conducted to evaluate the effects of density-medium type, centrifuge-tube size, sperm number, and density-medium volume (column height) on stallion sperm quality and recovery rate in sperm pellets following centrifugation. In all three experiments, equine semen was initially centrifuged to increase sperm concentration. In Experiment 1, semen was layered over continuous or discontinuous gradients. For Experiment 2, semen was layered over three column heights of continuous gradients in 15- or 50-ml conical-bottom tubes. For Experiment 3, increasing sperm numbers were layered over continuous gradient in 15- or 50-ml conical-bottom tubes. Following centrifugation, sperm pellets were evaluated for sperm morphologic quality, motility, DNA integrity, and recovery rate. Centrifugal fractionation improved (P < 0.05) sperm morphology, motility, and DNA integrity, as compared to controls. The continuous gradient increased (P < 0.05) sperm recovery rate relative to the discontinuous gradient, whereas sperm processed in 15-ml tubes yielded higher velocity and higher recovery rates (P < 0.05 for each) than that processed in 50-ml tubes. Sperm recovery rate was not affected (P > 0.05) by column height of gradient. Increasing sperm number subjected to gradient centrifugation decreased (P < 0.05) sperm recovery rate when 15-ml tubes were used. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Tolerance of Snakes to Hypergravity

    NASA Technical Reports Server (NTRS)

    Lillywhite, H. B.; Ballard, R. E.; Hargens, A. R.

    1994-01-01

    Sensitivity of carotid blood flow to +Gz (head-to-tail) acceleration was studied in six species of snakes hypothesized to show varied adaptive cardiovascular responses to gravity. Blood flow in the proximal carotid artery was measured in 15 snakes before, during and following stepwise increments of +0.25Gz force produced on a 2.4 m diameter centrifuge. During centrifugation each snake was confined to a straight position within an individually- fitted acrylic tube with the head facing the center of rotation. We measured the centrifugal force at the tail of the snake in order to quantify the maximum intensity of force gradient promoting antero-posterior pooling of blood. Tolerance to increased gravity was quantified as the acceleration force at which carotid blood flow ceased. This parameter varied according to the gravitational adaptation of species defined by their ecology and behavior. At the extremes, carotid blood flow decreased in response to increasing gravity and approached zero near +1Gz in aquatic and ground-dwelling species, whereas in climbing species carotid flow was maintained at forces in excess of +2Gz. Surprisingly, tolerant (arboreal) species withstood hypergravic forces of +2 to +3 G. for periods up to 1 h without cessation of carotid blood flow or apparent loss of consciousness. Data suggest that relatively tight skin of the tolerant species provides a natural antigravity suit which is of prime importance in counteracting Gz stress on blood circulation.

  4. Effects of various physical stress factors on mitochondrial function and reactive oxygen species in rat spermatozoa

    PubMed Central

    Kim, Suhee; Agca, Cansu; Agca, Yuksel

    2013-01-01

    The aim of the present study was to evaluate the effects of various physical interventions on the function of epididymal rat spermatozoa and determine whether there are correlations among these functional parameters. Epididymal rat spermatozoa were subjected to various mechanical (pipetting, centrifugation and Percoll gradient separation) and anisotonic conditions, and sperm motility, plasma membrane integrity (PMI), mitochondrial membrane potential (MMP) and intracellular reactive oxygen species (ROS) were evaluated. Repeated pipetting caused a loss in motility, PMI and MMP (P < 0.05). Minimal centrifugation force (200g) had no effect on motility, PMI and MMP, whereas an increase in the centrifugation force to 400g or 600g decreased sperm function (P < 0.005). Percoll gradient separation increased total motility, PMI and MMP (P < 0.05). However, the spermatozoa that were subjected to mechanical interventions showed high susceptibility to a ROS stimulant (P < 0.005). Anisotonic conditions decreased motility, PMI and MMP, and hypotonic conditions in particular increased basal ROS (P < 0.05). In correlation tests, there were strong positive correlations among total motility, PMI and MMP, whereas ROS showed no or negatively weak correlations with the other parameters. In conclusion, the physical interventions may act as important variables, affecting functional parameters of epididymal rat spermatozoa. Therefore, careful consideration and proper protocols for handling of rat spermatozoa and osmotic conditions are required to achieve reliable results and minimise damage. PMID:23140582

  5. Excessive centrifugal fields damage high density lipoprotein[S

    PubMed Central

    Munroe, William H.; Phillips, Martin L.; Schumaker, Verne N.

    2015-01-01

    HDL is typically isolated ultracentrifugally at 40,000 rpm or greater, however, such high centrifugal forces are responsible for altering the recovered HDL particle. We demonstrate that this damage to HDL begins at approximately 30,000 rpm and the magnitude of loss increases in a rotor speed-dependent manner. The HDL is affected by elevated ultracentrifugal fields resulting in a lower particle density due to the shedding of associated proteins. To circumvent the alteration of the recovered HDL, we utilize a KBr-containing density gradient and a lowered rotor speed of 15,000 rpm to separate the lipoproteins using a single 96 h centrifugation step. This recovers the HDL at two density ranges; the bulk of the material has a density of about 1.115 g/ml, while lessor amounts of material are recovered at >1.2 g/ml. Thus, demonstrating the isolation of intact HDL is possible utilizing lower centrifuge rotor speeds. PMID:25910941

  6. Pressure anisotropy and radial stress balance in the Jovian neutral sheet

    NASA Technical Reports Server (NTRS)

    Paranicas, C. P.; Mauk, B. H.; Krimigis, S. M.

    1991-01-01

    By examining particle and magnetic field data from the Voyager 1 and 2 spacecraft, signatures were found indicating that the (greater than about 28 keV) particle pressure parallel to the magnetic field is greater than the pressure perpendicular to the field within the nightside neutral sheet (three nightside neutral sheet crossings, with favorable experimental conditions, were used). By incorporating the pressure anisotropy into the calculation of radial forces within the hightside neutral sheet, it is found that (1) force balance is approximately achieved and (2) the anisotropy force term provides the largest contribution of the other particle forces considered (pressure gradients and the corotation centrifugal force). With regard to the problem of understanding the balance of radial forces within the dayside neutral sheet (McNutt, 1984; Mauk and Krimigis, 1987), the nightside pressure anisotropy force is larger than the dayside pressure gradient forces at equivalent radial distances; however, a full accounting of the dayside regions remains to be achieved.

  7. The Vortex of Burgers in Protoplanetary Disc

    NASA Astrophysics Data System (ADS)

    Abrahamyan, M. G.

    2017-07-01

    The effect of a Burgers vortex on formation of planetesimals in a protoplanetary disc in local approach is considered. It is shown that there is not any circular orbit for rigid particles in centrifugal balance; only stable position in Burgers vortex under the influence of centrifugal, Coriolis, pressure gradient and Stokes drag forces is the center of vortex. The two-dimensional anticyclonic Burgers vortex with homogeneously rotating kernel and a converging radial stream of substance can effectively accumulate in its nuclear area the meter- sized rigid particles of total mass ˜1028g for characteristic time ˜106yr.

  8. Effect of density gradient centrifugation on reactive oxygen species in human semen.

    PubMed

    Takeshima, Teppei; Yumura, Yasushi; Kuroda, Shinnosuke; Kawahara, Takashi; Uemura, Hiroji; Iwasaki, Akira

    2017-06-01

    Density gradient centrifugation can separate motile sperm from immotile sperm and other cells for assisted reproduction, but may also remove antioxidants from seminal plasma, resulting in oxidative stress. Therefore, we investigated reactive oxygen species (ROS) concentrations and distribution in semen before and after density gradient centrifugation. We assessed semen volume, sperm concentration, sperm motility, and ROS levels before and after density gradient centrifugation (300 x g for 20 minutes) in 143 semen samples from 118 patients. The ROS removal rate was evaluated in ROS-positive samples and ROS formation rate in ROS-negative samples. Thirty-eight of 143 untreated samples (26.6%) were ROS-positive; sperm motility was significantly lower in these samples than in ROS-negative samples (p < 0.05). After density gradient centrifugation, only seven of the 38 ROS-positive samples (18.42%) exhibited a ROS-positive lower layer (containing motile sperm) with a ROS removal rate of 81.58%, whereas the upper layer was ROS-positive in 24 samples (63.16%). In the ROS-negative group (n = 105), ROS was detected in 19 samples after centrifugation (18.10%, ROS generation rate), of which 18 were ROS-positive only in the upper layer or interface and the other was ROS-positive in both layers. Density gradient centrifugation can separate motile sperm from immotile sperm as well as remove ROS (including newly generated ROS). This data supports the view that density gradient centrifugation can select motile spermatozoa without enhancing oxidative stress. ROS: reactive oxygen species; SOD: superoxide dismutase; GPx: glutathione peroxidase; DNA: deoxyribonucleic acid; DGC: density gradient centrifugation; IUI: intrauterine insemination; IVF: in vitro fertilization; HEPES: 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid; EDTA: ethylenediaminetetraacetic acid; HTF: HEPES-buffered human tubal fluid; IMSI: intracytoplasmic morphologically selected sperm injection; SMAS: sperm motility analyzing system; CASA: computer-assisted semen analyzer; WHO: World Health Organization.

  9. Method of analysis for compressible flow through mixed-flow centrifugal impellers of arbitrary design

    NASA Technical Reports Server (NTRS)

    Hamrick, Joseph T; Ginsburg, Ambrose; Osborn, Walter M

    1952-01-01

    A method is presented for analysis of the compressible flow between the hub and the shroud of mixed-flow impellers of arbitrary design. Axial symmetry was assumed, but the forces in the meridional (hub to shroud) plane, which are derived from tangential pressure gradients, were taken into account. The method was applied to an experimental mixed-flow impeller. The analysis of the flow in the meridional plane of the impeller showed that the rotational forces, the blade curvature, and the hub-shroud profile can introduce severe velocity gradients along the hub and the shroud surfaces. Choked flow at the impeller inlet as determined by the analysis was verified by experimental results.

  10. Hybrid simulations of radial transport driven by the Rayleigh-Taylor instability

    NASA Astrophysics Data System (ADS)

    Delamere, P. A.; Stauffer, B. H.; Ma, X.

    2017-12-01

    Plasma transport in the rapidly rotating giant magnetospheres is thought to involve a centrifugally-driven flux tube interchange instability, similar to the Rayleigh-Taylor (RT) instability. In three dimensions, the convective flow patterns associated with the RT instability can produce strong guide field reconnection, allowing plasma mass to move radially outward while conserving magnetic flux (Ma et al., 2016). We present a set of hybrid (kinetic ion / fluid electron) plasma simulations of the RT instability using high plasma beta conditions appropriate for Jupiter's inner and middle magnetosphere. A density gradient, combined with a centrifugal force, provide appropriate RT onset conditions. Pressure balance is achieved by initializing two ion populations: one with fixed temperature, but varying density, and the other with fixed density, but a temperature gradient that offsets the density gradient from the first population and the centrifugal force (effective gravity). We first analyze two-dimensional results for the plane perpendicular to the magnetic field by comparing growth rates as a function of wave vector following Huba et al. (1998). Prescribed perpendicular wave modes are seeded with an initial velocity perturbation. We then extend the model to three dimensions, introducing a stabilizing parallel wave vector. Boundary conditions in the parallel direction prohibit motion of the magnetic field line footprints to model the eigenmodes of the magnetodisc's resonant cavity. We again compare growth rates based on perpendicular wave number, but also on the parallel extent of the resonant cavity, which fixes the size of the largest parallel wavelength. Finally, we search for evidence of strong guide field magnetic reconnection within the domain by identifying areas with large parallel electric fields or changes in magnetic field topology.

  11. Cardiovascular responses of semi-arboreal snakes to chronic, intermittent hypergravity

    NASA Technical Reports Server (NTRS)

    Lillywhite, H. B.; Ballard, R. E.; Hargens, A. R.

    1996-01-01

    Cardiovascular functions were studied in semi-arboreal rat snakes (Elaphe obsoleta) following long-term, intermittent exposure to +1.5 Gz (head-to-tail acceleration) on a centrifuge. Snakes were held in a nearly straight position within horizontal plastic tubes during periods of centrifugation. Centrifugal acceleration, therefore, subjected snakes to a linear force gradient with the maximal force being experienced at the tail. Compared to non-centrifuged controls, Gz-acclimated snakes showed greater increases of heart rate during head-up tilt or acceleration, greater sensitivity of arterial pressure to circulating catecholamines, higher blood levels of corticosterone, and higher blood ratios of prostaglandin F 2 alpha/prostaglandin E2. Cardiovascular tolerance to increased gravity during graded Gz acceleration was measured as the maximum (caudal) acceleration force at which carotid arterial blood flow became null. When such tolerances were adjusted for effects of body size and other continuous variables incorporated into an analysis of covariance, the difference between the adjusted mean values of control and acclimated snakes (2.37 and 2.84 Gz, respectively) corresponded closely to the 0.5 G difference between the acclimation G (1.5) and Earth gravity (1.0). As in other vertebrates, cardiovascular tolerance to Gz stress tended to be increased by acclimation, short body length, high arterial pressure, and comparatively large blood volume. Voluntary body movements were important for promoting carotid blood flow at the higher levels of Gz stress.

  12. Practical utilization of spICP-MS to study sucrose density gradient centrifugation for the separation of nanoparticles.

    PubMed

    Johnson, Monique E; Montoro Bustos, Antonio R; Winchester, Michael R

    2016-11-01

    Single particle inductively coupled plasma mass spectrometry (spICP-MS) is shown to be a practical technique to study the efficacy of rate-zonal sucrose density gradient centrifugation (SDGC) separations of mixtures of gold nanoparticles (AuNPs) in liquid suspension. spICP-MS enabled measurements of AuNP size distributions and particle number concentrations along the gradient, allowing unambiguous evaluations of the effectiveness of the separation. Importantly, these studies were conducted using AuNP concentrations that are directly relevant to environmental studies (sub ng mL -1 ). At such low concentrations, other techniques [e.g., dynamic light scattering (DLS), transmission and scanning electron microscopies (TEM and SEM), UV-vis spectroscopy, atomic force microscopy (AFM)] do not have adequate sensitivity, highlighting the inherent value of spICP-MS for this and similar applications. In terms of the SDGC separations, a mixture containing three populations of AuNPs, having mean diameters of 30, 80, and 150 nm, was fully separated, while separations of two other mixtures (30, 60, 100 nm; and 20, 50, 100 nm) were less successful. Finally, it is shown that the separation capacity of SDGC can be overwhelmed when particle number concentrations are excessive, an especially relevant finding in view of common methodologies taken in nanotechnology research. Graphical Abstract Characterization of the separation of a gold nanoparticle mixture by sucrose density gradient centrifugation by conventional and single particle ICP-MS analysis.

  13. Numerical studies of surface tensions

    NASA Technical Reports Server (NTRS)

    Hung, R. J.

    1995-01-01

    Liquid-vapor (bubble) interface disturbances caused by various types of accelerations, including centrifugal, lateral and axial impulses, gravity gradient and g-jitter accelerations associated with spinning and slew motion in microgravity, are reviewed. Understanding of bubble deformations and fluctuations is important in the development of spacecraft orbital and attitude control techniques to secure its normal operation. This review discusses bubble deformations and oscillations driven by various forces in the microgravity environment. The corresponding bubble mass center fluctuations and slosh reaction forces and torques due to bubble deformations are also reviewed.

  14. An Experiment Using Sucrose Density Gradients in the Undergraduate Biochemistry Laboratory.

    ERIC Educational Resources Information Center

    Turchi, Sandra L.; Weiss, Monica

    1988-01-01

    Describes an experiment to be performed in an undergraduate biochemistry laboratory that is based on a gradient centrifugation system employing a simple bench top centrifuge, a freezer, and frozen surcose gradient solution to separate macromolecules and subcellular components. (CW)

  15. Fluid flow through a high cell density fluidized-bed during centrifugal bioreactor culture.

    PubMed

    Detzel, Christopher J; Van Wie, Bernard J; Ivory, Cornelius F

    2010-01-01

    An increasing demand for products such as tissues, proteins, and antibodies from mammalian cell suspension cultures is driving interest in increasing production through high-cell density bioreactors. The centrifugal bioreactor (CCBR) retains cells by balancing settling forces with surface drag forces due to medium throughput and is capable of maintaining cell densities above 10(8) cells/mL. This article builds on a previous study where the fluid mechanics of an empty CCBR were investigated showing fluid flow is nonuniform and dominated by Coriolis forces, raising concerns about nutrient and cell distribution. In this article, we demonstrate that the previously reported Coriolis forces are still present in the CCBR, but masked by the presence of cells. Experimental dye injection observations during culture of 15 microm hybridoma cells show a continual uniform darkening of the cell bed, indicating the region of the reactor containing cells is well mixed. Simulation results also indicate the cell bed is well mixed during culture of mammalian cells ranging in size from 10 to 20 microm. However, simulations also allow for a slight concentration gradient to be identified and attributed to Coriolis forces. Experimental results show cell density increases from 0.16 to 0.26 when centrifugal force is doubled by increasing RPM from 650 to 920 at a constant inlet velocity of 6.5 cm/s; an effect also observed in the simulation. Results presented in this article indicate cells maintained in the CCBR behave as a high-density fluidized bed of cells providing a homogeneous environment to ensure optimal growth conditions. (c) 2010 American Institute of Chemical Engineers

  16. Fluid Flow through a High Cell Density Fluidized-Bed during Centrifugal Bioreactor Culture

    PubMed Central

    Detzel, Christopher J.; Van Wie, Bernard J.; Ivory, Cornelius F.

    2010-01-01

    An increasing demand for products such as tissues, proteins, and antibodies from mammalian cell suspension cultures is driving interest in increasing production through high-cell density bioreactors. The centrifugal bioreactor (CCBR) retains cells by balancing settling forces with surface drag forces due to medium throughput and is capable of maintaining cell densities above 108 cells/mL. This article builds on a previous study where the fluid mechanics of an empty CCBR were investigated showing fluid flow is nonuniform and dominated by Coriolis forces, raising concerns about nutrient and cell distribution. In this article, we demonstrate that the previously reported Coriolis forces are still present in the CCBR, but masked by the presence of cells. Experimental dye injection observations during culture of 15 μm hybridoma cells show a continual uniform darkening of the cell bed, indicating the region of the reactor containing cells is well mixed. Simulation results also indicate the cell bed is well mixed during culture of mammalian cells ranging in size from 10 to 20 μm. However, simulations also allow for a slight concentration gradient to be identified and attributed to Coriolis forces. Experimental results show cell density increases from 0.16 to 0.26 when centrifugal force is doubled by increasing RPM from 650 to 920 at a constant inlet velocity of 6.5 cm/s; an effect also observed in the simulation. Results presented in this article indicate cells maintained in the CCBR behave as a high-density fluidized bed of cells providing a homogeneous environment to ensure optimal growth conditions. PMID:20205172

  17. Comparison of two sperm processing techniques for low complexity assisted fertilization: sperm washing followed by swim-up and discontinuous density gradient centrifugation.

    PubMed

    Fácio, Cássio L; Previato, Lígia F; Machado-Paula, Ligiane A; Matheus, Paulo Cs; Araújo, Edilberto

    2016-12-01

    This study aimed to assess and compare sperm motility, concentration, and morphology recovery rates, before and after processing through sperm washing followed by swim-up or discontinuous density gradient centrifugation in normospermic individuals. Fifty-eight semen samples were used in double intrauterine insemination procedures; 17 samples (group 1) were prepared with sperm washing followed by swim-up, and 41 (group 2) by discontinuous density gradient centrifugation. This prospective non-randomized study assessed seminal parameters before and after semen processing. A dependent t-test was used for the same technique to analyze seminal parameters before and after semen processing; an independent t-test was used to compare the results before and after processing for both techniques. The two techniques produced decreases in sample concentration (sperm washing followed by swim-up: P<0.000006; discontinuous density gradient centrifugation: P=0.008457) and increases in motility and normal morphology sperm rates after processing. The difference in sperm motility between the two techniques was not statistically significant. Sperm washing followed by swim-up had better morphology recovery rates than discontinuous density gradient centrifugation (P=0.0095); and the density gradient group had better concentration recovery rates than the swim-up group (P=0.0027). The two methods successfully recovered the minimum sperm values needed to perform intrauterine insemination. Sperm washing followed by swim-up is indicated for semen with high sperm concentration and better morphology recovery rates. Discontinuous density gradient centrifugation produced improved concentration recovery rates.

  18. Virus purification by CsCl density gradient using general centrifugation.

    PubMed

    Nasukawa, Tadahiro; Uchiyama, Jumpei; Taharaguchi, Satoshi; Ota, Sumire; Ujihara, Takako; Matsuzaki, Shigenobu; Murakami, Hironobu; Mizukami, Keijirou; Sakaguchi, Masahiro

    2017-11-01

    Virus purification by cesium chloride (CsCl) density gradient, which generally requires an expensive ultracentrifuge, is an essential technique in virology. Here, we optimized virus purification by CsCl density gradient using general centrifugation (40,000 × g, 2 h, 4 °C), which showed almost the same purification ability as conventional CsCl density gradient ultracentrifugation (100,000 × g, 1 h, 4 °C) using phages S13' and φEF24C. Moreover, adenovirus strain JM1/1 was also successfully purified by this method. We suggest that general centrifugation can become a less costly alternative to ultracentrifugation for virus purification by CsCl densiy gradient and will thus encourage research in virology.

  19. Defense Small Business Innovation Research Program (SBIR). Volume 3. Air Force Abstracts of Phase 1 Awards 1993

    DTIC Science & Technology

    1993-01-01

    design and centrifugation protocols. A validated model of the cardiovascular and vestibular response to High Gradient Acceleration (HGA) is vital to...hermetically sealed compressors for long life Stirling and Pulse Tube Cryocoolers for spacecraft. State-of-the art compressors use unlubricated flexure...displacement and vibration cancellation. The inexpensive compressor proposed for Stirling and Pulse Tube cycle spacecraft cryocoolers makes use of

  20. Mito-magneto: A Tool for Nanoparticle Mediated Mitochondria Isolation†

    PubMed Central

    Banik, Bhabatosh; Askins, Brett W.; Dhar, Shanta

    2016-01-01

    The field of intracellular organelle targeting using nanoparticles (NPs) is mushrooming rapidly. Thus, the area of nanotechnology-enabled targeting of mitochondrion, the cellular powerhouse, for diseases characterized by mitochondrial dysfunctions such as cancer, diseases of the central nervous system, cardiovascular diseases is also growing at a rapid pace. Optimization of NP’s ability to target the mitochondria requires quantification of the particles in this subcellular organelle and isolation of mitochondria from cells. Conventional gradient centrifugation used in currently available methods may not be appropriate for NP containing mitochondria isolation as these particles undergo Brownian motion under centrifugal forces yielding irreproducible results. There is only one method for centrifugation free mitochondria isolation, however this method requires immune-precipitation. Thus, a reliable centrifugation and immune-precipitation free method is urgently needed to support this growing field of nanotechnology-based mitochondria targeting. Here, we report a mitochondria-targeted magnetic NP, Mito-magneto, to avoid centrifugation and immune precipitation methods for isolation of functional, respiration active pure mitochondria which can be used to analyze and quantify mitochondria targeting properties of various NPs to provide an important tool for the growing field of “mitochondrial nanomedicine”. PMID:27735003

  1. Research of Mechanical Property Gradient Distribution of Al-Cu Alloy in Centrifugal Casting

    NASA Astrophysics Data System (ADS)

    Sun, Zhi; Sui, Yanwei; Liu, Aihui; Li, Bangsheng; Guo, Jingjie

    Al-Cu alloy castings are obtained using centrifugal casting. The regularity of mechanical property gradient distribution of Al-Cu alloy castings with the same centrifugal radius at different positions is investigated. The result shows that the tensile strength, yield strength, elongation and microscope hardness exhibit the following gradient distribution characteristic — high on both sides and low on the center. The trend of mechanical property gradient distribution of Al-Cu alloy increases with the increase in the rotation speed. Moreover, the mechanical properties of casting centerline two sides have asymmetry. The reason is that the grain size of casting centerline two sides and Al2Cu phase and Cu content change correspondingly.

  2. Development of an Artificial Gravity Sleeper (AGS)

    NASA Technical Reports Server (NTRS)

    Cardus, David; Mctaggart, Wesley G.; Diamandis, Peter; Campbell, Scott

    1990-01-01

    The design and construction of a 2-meter radius 'human compatible' centrifuge termed the Artificial Gravity Sleeper (AGS) is considered. The centrifuge will accommodate up to four subjects at a time, operate at a broad range of speeds, and have safety features. Experiments that will be conducted on the AGS will help to investigate the quality of sleep during 100 percent gradient centrifugation. A microgravity simulation also will be studied using bed rest to assess the ability of 100 percent gradient centrifugation to function as a countermeasure to cardiovascular deconditioning.

  3. Evaluation of the qualitative and quantitative effectiveness of three media of centrifugation (Maxifreeze, Cushion Fluid Equine, and PureSperm 100) in preparation of fresh or frozen-thawed brown bear spermatozoa.

    PubMed

    Nicolas, M; Alvarez, M; Borragán, S; Martinez-Pastor, F; Chamorro, C A; Alvarez-Rodriguez, M; de Paz, P; Anel, L

    2012-04-01

    Centrifugation is a crucial procedure in sperm cryopreservation protocols of brown bear (Ursus arctos), because the semen must be processed to increase sperm concentration and/or clean urine-contaminated samples. The efficacy of three media for centrifugation (Maxifreeze [IMV technologies, L'Aigle, France], Cushion Fluid Equine (Minitübe, Tiefenbach, Germany), and PureSperm [Nidacon, Gothenburg, Sweden]) on the quality of bear spermatozoa was evaluated. In experiment one, two cushioned media used for protecting against mechanical stress during centrifugation were analyzed. In experiment two, a density gradient based on PureSperm was assessed in relation to the maximum retrieval and the quality of fresh spermatozoa, and the freezability of the spermatozoa selected in this density gradient was studied in experiment three. Finally, the selection of frozen-thawed sperm using PureSperm was analyzed in experiment four. Our results indicate that the use of dense isotonic cushion solutions (Maxifreeze, Cushion Fluid Equine) in centrifugation did not improve the quality of recovered spermatozoa compared with standard centrifugation. However, a density gradient prepared with PureSperm improved the quality of spermatozoa in fresh semen and frozen-thawed semen, but the spermatozoa selected from the fresh sample with this density gradient did not show a better resistance to freezing with this density gradient in comparison with the control sample. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Using Magnetic Forces to Probe the Gravi-response of Swimming Paramecium

    NASA Astrophysics Data System (ADS)

    Guevorkian, Karine; Valles, James M., Jr.

    2004-03-01

    Paramecium Caudatum, a single celled ciliate, alters its swimming behavior when subjected to different gravity environments (e.g. centrifugation and micro-gravity). To dissect the mechanisms behind this gravi-response and that of other biological systems, we are developing the use of magnetic body forces as a means of creating a rapidly tunable, simulated variable gravity environment. Since biological materials are weakly diamagnetic, we must subject them to intense inhomogeneous magnetic fields with characteristic field-field gradient products on the order of 16 T^2/cm. We will describe experiments on Paramecium Caudatum in which we adjust their net buoyancy with magnetic forces and measure the resulting changes in their swimming behavior.

  5. Is Urografin density gradient centrifugation suitable to separate nonculturable cells from Escherichia coli populations?

    PubMed

    Arana, Inés; Orruño, Maite; Seco, Carolina; Muela, Alicia; Barcina, Isabel

    2008-03-01

    The ability of Urografin or Percoll density gradient centrifugations to separate nonculturable subpopulations from heterogeneous Escherichia coli populations was analysed. Bacterial counts (total, active and culturable cells) and flow cytometric analyses were carried out in all recovered bands. After Urografin centrifugation, and despite the different origin of E. coli populations, a common pattern was obtained. High-density bands were formed mainly by nonculturable cells. However, the increase in cell density would not be common to all nonculturable cells, since part of this subpopulations banded in low-density zones, mixed with culturable cells. Bands obtained after Percoll centrifugation were heterogeneous and culturable and nonculturable cells were recovered along the gradient. Thus, fractionation in Urografin cannot be only attributed to changes in buoyant densities during the transition from culturable to nonculturable state. Urografin density gradients allow us to obtain enriched fractions in nonculturable subpopulations from a heterogeneous population, but working conditions should be carefully chosen to avoid Urografin toxicity.

  6. Selective retension of active cells employing low centrifugal force at the medium change during suspension culture of Chinese hamster ovary cells producing tPA.

    PubMed

    Takagi, M; Ilias, M; Yoshida, T

    2000-01-01

    The effect of centrifugal force applied for cell separation at the medium change on the growth, metabolism and tissue plasminogen activator (tPA) productivity of Chinese hamster ovary (CHO) cells suspension culture was investigated. The viability of the precipitated cells increased exponentially as the centrifugal force decreased. However, the cell recovery was lower than 91% when centrifugal forces applied for 5 min was less than 67 x g. In cultures incubated for 474 h with 7 medium changes employing centrifugal forces ranging from 67 to 364 x g, a centrifugal force lower than 119 x g resulted in higher specific rates of growth, glucose consumption, and lactate and tPA production during the whole culture period. On the other hand, daily centrifugation at 67 to 537 x g without discarding the supernatant had no effect on the specific rates. The cultures inoculated with cells precipitated at a centrifugal force of 67 x g showed apparently higher specific rates of metabolism compared to those inoculated with cells in the supernatant. The cells in the supernatant and the precipitate obtained following centrifugation at 67 x g have average diameters of 15.5 and 17.4 microm, respectively. The intracellular contents of amino acids, especially nonessential amino acids, of the precipitated cells were markedly higher than those of the cells in the supernatant. These results indicate that large cells with high amino acid content and metabolic activity were selectively retained in the culture by means of centrifugation at low forces such as 67 x g. Consequently, application of a low centrifugal force is recommended for medium change in order to maintain higher specific productivity of suspended mammalian cells in perfusion culture.

  7. Purification of white spot syndrome virus by iodixanol density gradient centrifugation.

    PubMed

    Dantas-Lima, J J; Corteel, M; Cornelissen, M; Bossier, P; Sorgeloos, P; Nauwynck, H J

    2013-10-01

    Up to now, only a few brief procedures for purifying white spot syndrome virus (WSSV) have been described. They were mainly based on sucrose, NaBr and CsCl density gradient centrifugation. This work describes for the first time the purification of WSSV through iodixanol density gradients, using virus isolated from infected tissues and haemolymph of Penaeus vannamei (Boone). The purification from tissues included a concentration step by centrifugation (2.5 h at 60,000 g) onto a 50% iodixanol cushion and a purification step by centrifugation (3 h at 80,000 g) through a discontinuous iodixanol gradient (phosphate-buffered saline, 5%, 10%, 15% and 20%). The purification from infected haemolymph enclosed a dialysis step with a membrane of 1,000 kDa (18 h) and a purification step through the earlier iodixanol gradient. The gradients were collected in fractions and analysed. The number of particles, infectivity titre (in vivo), total protein and viral protein content were evaluated. The purification from infected tissues gave WSSV suspensions with a very high infectivity and an acceptable purity, while virus purified from haemolymph had a high infectivity and a very high purity. Additionally, it was observed that WSSV has an unusually low buoyant density and that it is very sensitive to high external pressures. © 2013 John Wiley & Sons Ltd.

  8. Centrifugal precipitation chromatography

    PubMed Central

    Ito, Yoichiro; Lin, Qi

    2009-01-01

    Centrifugal precipitation chromatography separates analytes according their solubility in ammonium sulfate (AS) solution and other precipitants. The separation column is made from a pair of long spiral channels partitioned with a semipermeable membrane. In a typical separation, concentrated ammonium sulfate is eluted through one channel while water is eluted through the other channel in the opposite direction. The countercurrent process forms an exponential AS concentration gradient through the water channel. Consequently, protein samples injected into the water channel is subjected to a steadily increasing AS concentration and at the critical AS concentration they are precipitated and deposited in the channel bed by the centrifugal force. Then the chromatographic separation is started by gradually reducing the AS concentration in the AS channel which lowers the AS gradient concentration in the water channel. This results in dissolution of deposited proteins which are again precipitated at an advanced critical point as they move through the channel. Consequently, proteins repeat precipitation and dissolution through a long channel and finally eluted out from the column in the order of their solubility in the AS solution. The present method has been successfully applied to a number of analytes including human serum proteins, recombinant ketosteroid isomerase, carotenoid cleavage enzymes, plasmid DNA, polysaccharide, polymerized pigments, PEG-protein conjugates, etc. The method is capable to single out the target species of proteins by affinity ligand or immunoaffinity separation. PMID:19541553

  9. Enhanced sensitivity of DNA- and rRNA-based stable isotope probing by fractionation and quantitative analysis of isopycnic centrifugation gradients.

    PubMed

    Lueders, Tillmann; Manefield, Mike; Friedrich, Michael W

    2004-01-01

    Stable isotope probing (SIP) of nucleic acids allows the detection and identification of active members of natural microbial populations that are involved in the assimilation of an isotopically labelled compound into nucleic acids. SIP is based on the separation of isotopically labelled DNA or rRNA by isopycnic density gradient centrifugation. We have developed a highly sensitive protocol for the detection of 'light' and 'heavy' nucleic acids in fractions of centrifugation gradients. It involves the fluorometric quantification of total DNA or rRNA, and the quantification of either 16S rRNA genes or 16S rRNA in gradient fractions by real-time PCR with domain-specific primers. Using this approach, we found that fully 13C-labelled DNA or rRNA of Methylobacterium extorquens was quantitatively resolved from unlabelled DNA or rRNA of Methanosarcina barkeri by cesium chloride or cesium trifluoroacetate density gradient centrifugation respectively. However, a constant low background of unspecific nucleic acids was detected in all DNA or rRNA gradient fractions, which is important for the interpretation of environmental SIP results. Consequently, quantitative analysis of gradient fractions provides a higher precision and finer resolution for retrieval of isotopically enriched nucleic acids than possible using ethidium bromide or gradient fractionation combined with fingerprinting analyses. This is a prerequisite for the fine-scale tracing of microbial populations metabolizing 13C-labelled compounds in natural ecosystems.

  10. SEAL FOR HIGH SPEED CENTRIFUGE

    DOEpatents

    Skarstrom, C.W.

    1957-12-17

    A seal is described for a high speed centrifuge wherein the centrifugal force of rotation acts on the gasket to form a tight seal. The cylindrical rotating bowl of the centrifuge contains a closure member resting on a shoulder in the bowl wall having a lower surface containing bands of gasket material, parallel and adjacent to the cylinder wall. As the centrifuge speed increases, centrifugal force acts on the bands of gasket material forcing them in to a sealing contact against the cylinder wall. This arrangememt forms a simple and effective seal for high speed centrifuges, replacing more costly methods such as welding a closure in place.

  11. Centrifuge in space fluid flow visualization experiment

    NASA Technical Reports Server (NTRS)

    Arnold, William A.; Wilcox, William R.; Regel, Liya L.; Dunbar, Bonnie J.

    1993-01-01

    A prototype flow visualization system is constructed to examine buoyancy driven flows during centrifugation in space. An axial density gradient is formed by imposing a thermal gradient between the two ends of the test cell. Numerical computations for this geometry showed that the Prandtl number plays a limited part in determining the flow.

  12. Conical coils counter-current chromatography for preparative isolation and purification of tanshinones from Salvia miltiorrhiza Bunge.

    PubMed

    Liang, Junling; Meng, Jie; Guo, Mengzhe; Yang, Zhi; Wu, Shihua

    2013-05-03

    Modern counter-current chromatography (CCC) originated from the helical coil planet centrifuge. Recently, spiral coils were found to possess higher separation efficiency in both the retention of stationary phase and solutes resolution than other CCC coils like the helical and toroidal coils used on type-J CCC and cross-axis CCC. In this work, we built a novel conical coil CCC for the preparative isolation and purification of tanshinones from Salvia miltiorrhiza Bunge. The conical coils were wound on three identical upright tapered holders in head-to-tail and left-handed direction and connected in series. Compared with helical and spiral coil CCC, conical coil CCC not only placed CCC column in a two-dimensional centrifugal field, but also provided a potential centrifugal force gradient both in axial and radial directions. The extra centrifugal gradient made mobile phase move faster and enabled CCC much higher retention of stationary phase and better resolution. As a result, higher efficiency has been obtained with the solvent system of hexane-ethyl acetate-methanol-water (HEMWat) with the volume ratio of 5:5:7:3 by using conical coil CCC apparatus. Four tanshinones, including cryptotanshinone (1), tanshinone I (2), 1,2-dihydrotanshinquinone (3) and tanshinone IIA (4), were well resolved from 500mg to 1g crude samples with high purity. Furthermore, the conical coil CCC can make a much higher solid phase retention, which makes it to be a powerful separation tool with high throughput. This is the first report about conical coil CCC for separation of tanshinones and it may also be an important advancement for natural products isolation. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. An Innovative Short Arm Centrifuge for Future Studies on the Effects of Artificial Gravity on the Human Body

    NASA Astrophysics Data System (ADS)

    Frett, Timo; Mayrhofer, Michael; Schwandtner, Johann; Anken, Ralf; Petrat, Guido

    2014-11-01

    In July 2013, the German Aerospace Center (DLR) in Cologne, Germany, commissioned its new medical research facility :envihab. One central element of the facility is a new type of short radius centrifuge called DLR-SAHC 1 (formerly known as :enviFuge), which has been developed in collaboration with AMST Systemtechnik GmbH, Ranshofen, Austria. The shift of subjects above heart-level on a short arm centrifuge allows unique studies on, e.g., the cardiovascular regulation in surroundings with a high gradient of artificial gravity. Equipped with the capacity to move the four nacelles along the acceleration axis simultaneously and independently from each other, the centrifuge allows the possibility to perform up to four complex trials in parallel. The maximal acceleration is 6 g at the foot level and each nacelle can accomodate an up to 150kg payload. Additional equipment can be mounted on two payload bays with a capacity of 100kg each. Standard features of the centrifuge include a motion capturing system with six cameras and two triaxial force plates to study the kinematics of physical exercise (e.g., squatting, jumping or vibration training) under increased gravity. Future projects involving SAHC 1 will allow the development and testing of potential countermeasures and training methods against the negative effects of weightlessness in space on human physiology. Due to the centrifuge's capability to hold heavy equipment, carrying out a variety of non-human life science experiments requiring complex and heavy hardware is also fully feasible.

  14. Bubble Eliminator Based on Centrifugal Flow

    NASA Technical Reports Server (NTRS)

    Gonda, Steve R.; Tsao, Yow-Min D.; Lee, Wenshan

    2004-01-01

    The fluid bubble eliminator (FBE) is a device that removes gas bubbles from a flowing liquid. The FBE contains no moving parts and does not require any power input beyond that needed to pump the liquid. In the FBE, the buoyant force for separating the gas from the liquid is provided by a radial pressure gradient associated with a centrifugal flow of the liquid and any entrained bubbles. A device based on a similar principle is described in Centrifugal Adsorption Cartridge System (MSC- 22863), which appears on page 48 of this issue. The FBE was originally intended for use in filtering bubbles out of a liquid flowing relatively slowly in a bioreactor system in microgravity. Versions that operate in normal Earth gravitation at greater flow speeds may also be feasible. The FBE (see figure) is constructed as a cartridge that includes two concentric cylinders with flanges at the ends. The outer cylinder is an impermeable housing; the inner cylinder comprises a gas-permeable, liquid-impermeable membrane covering a perforated inner tube. Multiple spiral disks that collectively constitute a spiral ramp are mounted in the space between the inner and outer cylinders. The liquid enters the FBE through an end flange, flows in the annular space between the cylinders, and leaves through the opposite end flange. The spiral disks channel the liquid into a spiral flow, the circumferential component of which gives rise to the desired centrifugal effect. The resulting radial pressure gradient forces the bubbles radially inward; that is, toward the inner cylinder. At the inner cylinder, the gas-permeable, liquid-impermeable membrane allows the bubbles to enter the perforated inner tube while keeping the liquid in the space between the inner and outer cylinders. The gas thus collected can be vented via an endflange connection to the inner tube. The centripetal acceleration (and thus the radial pressure gradient) is approximately proportional to the square of the flow speed and approximately inversely proportional to an effective radius of the annular space. For a given FBE geometry, one could increase the maximum rate at which gas could be removed by increasing the rate of flow to obtain more centripetal acceleration. In experiments and calculations oriented toward the original microgravitational application, centripetal accelerations between 0.001 and 0.012 g [where g normal Earth gravitation (.9.8 m/s2)] were considered. For operation in normal Earth gravitation, it would likely be necessary to choose the FBE geometry and the rate of flow to obtain centripetal acceleration comparable to or greater than g.

  15. Single-step fabrication of quantum funnels via centrifugal colloidal casting of nanoparticle films

    PubMed Central

    Kim, Jin Young; Adinolfi, Valerio; Sutherland, Brandon R.; Voznyy, Oleksandr; Kwon, S. Joon; Kim, Tae Wu; Kim, Jeongho; Ihee, Hyotcherl; Kemp, Kyle; Adachi, Michael; Yuan, Mingjian; Kramer, Illan; Zhitomirsky, David; Hoogland, Sjoerd; Sargent, Edward H.

    2015-01-01

    Centrifugal casting of composites and ceramics has been widely employed to improve the mechanical and thermal properties of functional materials. This powerful method has yet to be deployed in the context of nanoparticles—yet size–effect tuning of quantum dots is among their most distinctive and application-relevant features. Here we report the first gradient nanoparticle films to be constructed in a single step. By creating a stable colloid of nanoparticles that are capped with electronic-conduction-compatible ligands we were able to leverage centrifugal casting for thin-films devices. This new method, termed centrifugal colloidal casting, is demonstrated to form films in a bandgap-ordered manner with efficient carrier funnelling towards the lowest energy layer. We constructed the first quantum-gradient photodiode to be formed in a single deposition step and, as a result of the gradient-enhanced electric field, experimentally measured the highest normalized detectivity of any colloidal quantum dot photodetector. PMID:26165185

  16. Separation of Bacteria, Protozoa and Carbon Nanotubes by Density Gradient Centrifugation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mortimer, Monika; Petersen, Elijah; Buchholz, Bruce

    Sustainable production and use of carbon nanotube (CNT)-enabled materials require efficient assessment of CNT environmental hazards, including the potential for CNT bioaccumulation and biomagnification in environmental receptors. Microbes, as abundant organisms responsible for nutrient cycling in soil and water, are important ecological receptors for studying the effects of CNTs. Quantification of CNT association with microbial cells requires efficient separation of CNT-associated cells from individually dispersed CNTs and CNT agglomerates. Here in this paper, we designed, optimized, and demonstrated procedures for separating bacteria (Pseudomonas aeruginosa) from unbound multiwall carbon nanotubes (MWCNTs) and MWCNT agglomerates using sucrose density gradient centrifugation. We demonstratemore » separation of protozoa (Tetrahymena thermophila) from MWCNTs, bacterial agglomerates, and protozoan fecal pellets by centrifugation in an iodixanol solution. The presence of MWCNTs in the density gradients after centrifugation was determined by quantification of 14C-labeled MWCNTs; the recovery of microbes from the density gradient media was confirmed by optical microscopy. Protozoan intracellular contents of MWCNTs and of bacteria were also unaffected by the designed separation process. Lastly, the optimized methods contribute to improved efficiency and accuracy in quantifying MWCNT association with bacteria and MWCNT accumulation in protozoan cells, thus supporting improved assessment of CNT bioaccumulation.« less

  17. Separation of Bacteria, Protozoa and Carbon Nanotubes by Density Gradient Centrifugation

    DOE PAGES

    Mortimer, Monika; Petersen, Elijah; Buchholz, Bruce; ...

    2016-10-12

    Sustainable production and use of carbon nanotube (CNT)-enabled materials require efficient assessment of CNT environmental hazards, including the potential for CNT bioaccumulation and biomagnification in environmental receptors. Microbes, as abundant organisms responsible for nutrient cycling in soil and water, are important ecological receptors for studying the effects of CNTs. Quantification of CNT association with microbial cells requires efficient separation of CNT-associated cells from individually dispersed CNTs and CNT agglomerates. Here in this paper, we designed, optimized, and demonstrated procedures for separating bacteria (Pseudomonas aeruginosa) from unbound multiwall carbon nanotubes (MWCNTs) and MWCNT agglomerates using sucrose density gradient centrifugation. We demonstratemore » separation of protozoa (Tetrahymena thermophila) from MWCNTs, bacterial agglomerates, and protozoan fecal pellets by centrifugation in an iodixanol solution. The presence of MWCNTs in the density gradients after centrifugation was determined by quantification of 14C-labeled MWCNTs; the recovery of microbes from the density gradient media was confirmed by optical microscopy. Protozoan intracellular contents of MWCNTs and of bacteria were also unaffected by the designed separation process. Lastly, the optimized methods contribute to improved efficiency and accuracy in quantifying MWCNT association with bacteria and MWCNT accumulation in protozoan cells, thus supporting improved assessment of CNT bioaccumulation.« less

  18. Separation of Bacteria, Protozoa and Carbon Nanotubes by Density Gradient Centrifugation

    PubMed Central

    Mortimer, Monika; Petersen, Elijah J.; Buchholz, Bruce A.; Holden, Patricia A.

    2016-01-01

    Sustainable production and use of carbon nanotube (CNT)-enabled materials require efficient assessment of CNT environmental hazards, including the potential for CNT bioaccumulation and biomagnification in environmental receptors. Microbes, as abundant organisms responsible for nutrient cycling in soil and water, are important ecological receptors for studying the effects of CNTs. Quantification of CNT association with microbial cells requires efficient separation of CNT-associated cells from individually dispersed CNTs and CNT agglomerates. Here, we designed, optimized, and demonstrated procedures for separating bacteria (Pseudomonas aeruginosa) from unbound multiwall carbon nanotubes (MWCNTs) and MWCNT agglomerates using sucrose density gradient centrifugation. We demonstrate separation of protozoa (Tetrahymena thermophila) from MWCNTs, bacterial agglomerates, and protozoan fecal pellets by centrifugation in an iodixanol solution. The presence of MWCNTs in the density gradients after centrifugation was determined by quantification of 14C-labeled MWCNTs; the recovery of microbes from the density gradient media was confirmed by optical microscopy. Protozoan intracellular contents of MWCNTs and of bacteria were also unaffected by the designed separation process. The optimized methods contribute to improved efficiency and accuracy in quantifying MWCNT association with bacteria and MWCNT accumulation in protozoan cells, thus supporting improved assessment of CNT bioaccumulation. PMID:27917301

  19. Repurposing a Benchtop Centrifuge for High-Throughput Single-Molecule Force Spectroscopy.

    PubMed

    Yang, Darren; Wong, Wesley P

    2018-01-01

    We present high-throughput single-molecule manipulation using a benchtop centrifuge, overcoming limitations common in other single-molecule approaches such as high cost, low throughput, technical difficulty, and strict infrastructure requirements. An inexpensive and compact Centrifuge Force Microscope (CFM) adapted to a commercial centrifuge enables use by nonspecialists, and integration with DNA nanoswitches facilitates both reliable measurements and repeated molecular interrogation. Here, we provide detailed protocols for constructing the CFM, creating DNA nanoswitch samples, and carrying out single-molecule force measurements.

  20. Separation of carbon nanotubes into chirally enriched fractions

    DOEpatents

    Doorn, Stephen K [Los Alamos, NM; Niyogi, Sandip [Los Alamos, NM

    2012-04-10

    A mixture of single-walled carbon nanotubes ("SWNTs") is separated into fractions of enriched chirality by preparing an aqueous suspension of a mixture of SWNTs and a surfactant, injecting a portion of the suspension on a column of separation medium having a density gradient, and centrifuging the column. In some embodiments, salt is added prior to centrifugation. In other embodiments, the centrifugation is performed at a temperature below room temperature. Fractions separate as colored bands in the column. The diameter of the separated SWNTs decreases with increasing density along the gradient of the column. The colored bands can be withdrawn separately from the column.

  1. Effect of the centrifugal force on domain chaos in Rayleigh-Bénard convection.

    PubMed

    Becker, Nathan; Scheel, J D; Cross, M C; Ahlers, Guenter

    2006-06-01

    Experiments and simulations from a variety of sample sizes indicated that the centrifugal force significantly affects the domain-chaos state observed in rotating Rayleigh-Bénard convection-patterns. In a large-aspect-ratio sample, we observed a hybrid state consisting of domain chaos close to the sample center, surrounded by an annulus of nearly stationary nearly radial rolls populated by occasional defects reminiscent of undulation chaos. Although the Coriolis force is responsible for domain chaos, by comparing experiment and simulation we show that the centrifugal force is responsible for the radial rolls. Furthermore, simulations of the Boussinesq equations for smaller aspect ratios neglecting the centrifugal force yielded a domain precession-frequency f approximately epsilon(mu) with mu approximately equal to 1 as predicted by the amplitude-equation model for domain chaos, but contradicted by previous experiment. Additionally the simulations gave a domain size that was larger than in the experiment. When the centrifugal force was included in the simulation, mu and the domain size were consistent with experiment.

  2. Steady-state force-velocity relation in the ATP-dependent sliding movement of myosin-coated beads on actin cables in vitro studied with a centrifuge microscope.

    PubMed Central

    Oiwa, K; Chaen, S; Kamitsubo, E; Shimmen, T; Sugi, H

    1990-01-01

    To eliminate the gap between the biochemistry of actomyosin in solution and the physiology of contracting muscle, we developed an in vitro force-movement assay system in which the steady-state force-velocity relation in the actin-myosin interaction can be studied. The assay system consists of the internodal cells of an alga, Nitellopsis obtusa, containing well-organized actin filament arrays (actin cables); tosyl-activated polystyrene beads (diameter, 2.8 microns; specific gravity, 1.3) coated with skeletal muscle myosin; and a centrifuge microscope equipped with a stroboscopic light source and a video system. The internodal cell preparation was mounted on the rotor of the centrifuge microscope, so that centrifugal forces were applied to the myosin-coated beads moving along the actin cables in the presence of ATP. Under constant centrifugal forces directed opposite to the bead movement ("positive" loads), the beads continued to move with constant velocities, which decreased with increasing centrifugal forces. The steady-state force-velocity curve thus obtained was analogous to the double-hyperbolic force-velocity curve of single muscle fibers. The unloaded velocity of bead movement was 1.6-3.6 microns/s (20-23 degrees C), while the maximum "isometric" force generated by the myosin molecules on the bead was 1.9-39 pN. If, on the other hand, the beads were subjected to constant centrifugal forces in the direction of bead movement ("negative" loads), the bead also moved with constant velocities. Unexpectedly, the velocity of bead movement did not increase with increasing negative loads but first decreased by 20-60% and then increased towards the initial unloaded velocity until the beads were eventually detached from the actin cables. Images PMID:2236007

  3. Steady-state force-velocity relation in the ATP-dependent sliding movement of myosin-coated beads on actin cables in vitro studied with a centrifuge microscope.

    PubMed

    Oiwa, K; Chaen, S; Kamitsubo, E; Shimmen, T; Sugi, H

    1990-10-01

    To eliminate the gap between the biochemistry of actomyosin in solution and the physiology of contracting muscle, we developed an in vitro force-movement assay system in which the steady-state force-velocity relation in the actin-myosin interaction can be studied. The assay system consists of the internodal cells of an alga, Nitellopsis obtusa, containing well-organized actin filament arrays (actin cables); tosyl-activated polystyrene beads (diameter, 2.8 microns; specific gravity, 1.3) coated with skeletal muscle myosin; and a centrifuge microscope equipped with a stroboscopic light source and a video system. The internodal cell preparation was mounted on the rotor of the centrifuge microscope, so that centrifugal forces were applied to the myosin-coated beads moving along the actin cables in the presence of ATP. Under constant centrifugal forces directed opposite to the bead movement ("positive" loads), the beads continued to move with constant velocities, which decreased with increasing centrifugal forces. The steady-state force-velocity curve thus obtained was analogous to the double-hyperbolic force-velocity curve of single muscle fibers. The unloaded velocity of bead movement was 1.6-3.6 microns/s (20-23 degrees C), while the maximum "isometric" force generated by the myosin molecules on the bead was 1.9-39 pN. If, on the other hand, the beads were subjected to constant centrifugal forces in the direction of bead movement ("negative" loads), the bead also moved with constant velocities. Unexpectedly, the velocity of bead movement did not increase with increasing negative loads but first decreased by 20-60% and then increased towards the initial unloaded velocity until the beads were eventually detached from the actin cables.

  4. Erosion in radial inflow turbines. Volume 2: Balance of centrifugal and radial drag forces on erosive particles

    NASA Technical Reports Server (NTRS)

    Clevenger, W. B., Jr.; Tabakoff, W.

    1974-01-01

    The particle motion in two-dimensional free and forced inward flowing vortices is considered. A particle in such a flow field experiences a balance between the aerodynamic drag forces that tend to drive erosive particles toward the axis, and centrifugal forces that prevent these particles from traveling toward the axis. Results predict that certain sizes of particles will achieve a stable orbit about the turbine axis in the inward flowing free vortex. In this condition, the radial drag force is equal to the centrifugal force. The sizes of particles that will achieve a stable orbit is shown to be related to the gas flow velocity diagram at a particular radius. A second analysis yields a description of particle sizes that will experience a centrifugal force that is greater than the radial component of the aerodynamic drag force for a more general type of particle motion.

  5. On the restricted four-body problem with the effect of small perturbations in the Coriolis and centrifugal forces

    NASA Astrophysics Data System (ADS)

    Suraj, Md Sanam; Aggarwal, Rajiv; Arora, Monika

    2017-09-01

    We have studied the restricted four-body problem (R4BP) with the effect of the small perturbation in the Coriolis and centrifugal forces on the libration points and zero velocity curves (ZVCs). Further, we have supposed that all the primaries are set in an equilateral triangle configuration, moving in the circular orbits around their common centre of mass. We have observed that the effect of the small perturbation in centrifugal force has a substantial effect on the location of libration points but a small perturbation in the Coriolis force has no impact on the location of libration points. But the stability of the libration points is highly influenced by the effect of the small perturbation in the Coriolis force. It is observed that as the Coriolis parameter increases, the libration points become stable. Further, it is found that the effect of the small perturbation in the centrifugal force has a substantial influence on the regions of possible motion. Also, when the effect of small perturbation in the centrifugal force increases the forbidden region decreases; here the motion is not possible for the infinitesimal mass. It is observed when the value of the Jacobian constant decreases, the regions of possible motion increase. In addition, we have also discussed how small perturbations in the Coriolis and centrifugal forces influence the Newton-Raphson basins of convergence.

  6. Hybrid gravity survey to search for submarine ore deposit

    NASA Astrophysics Data System (ADS)

    Araya, A.; Kanazawa, T.; Fujimoto, H.; Shinohara, M.; Yamada, T.; Mochizuki, K.; Iizasa, K.; Ishihara, T.; Omika, S.

    2011-12-01

    Along with seismic surveys, gravity survey is a useful method to profile the underground density structure. We propose a hybrid gravity survey using gravimeters and gravity gradiometers to detect submarine ore deposits as density anomalies by towing the instruments using an AUV (Autonomous Underwater Vehicle) or an ROV (Remotely Operated Vehicle). Gravimeters measure the regional density structure below the seafloor, whereas gravity gradiometers are sensitive to localized mass distribution. A gravity gradiometer comprises two accelerometers arranged with a vertical separation, and a gravity gradient can be obtained from the acceleration difference. Compared to gravimeters, gravity gradiometers are insensitive to common disturbances such as parallel acceleration, thermal drift, and apparent gravity effect (Eötvös effect). We made two accelerometers using astatic pendulums, and obtained common acceleration reduction more than two orders of magnitude. With these pendulums of 500-mm separation, resolution of 7E (=7x10^{-9}(1/s^2)), enough to detect a typical ore deposit buried 50m below the seafloor, was evaluated. During measurements using a submersible mobile object, instrument orientation is required to be controlled to keep verticality and to reduce centrifugal force associated with rotation of the instrument. Using a gyro and a tiltmeter, angular rotation was shown to be controlled within 0.001deg/s which corresponds to 0.3E in effective gravity gradient due to the centrifugal force. In this paper, target of this research, details of the instruments and their performance, and development for the submarine gravity survey using an AUV will be presented.

  7. Extraction of soil solution by drainage centrifugation-effects of centrifugal force and time of centrifugation on soil moisture recovery and solute concentration in soil moisture of loess subsoils.

    PubMed

    Fraters, Dico; Boom, Gerard J F L; Boumans, Leo J M; de Weerd, Henk; Wolters, Monique

    2017-02-01

    The solute concentration in the subsoil beneath the root zone is an important parameter for leaching assessment. Drainage centrifugation is considered a simple and straightforward method of determining soil solution chemistry. Although several studies have been carried out to determine whether this method is robust, hardly any results are available for loess subsoils. To study the effect of centrifugation conditions on soil moisture recovery and solute concentration, we sampled the subsoil (1.5-3.0 m depth) at commercial farms in the loess region of the Netherlands. The effect of time (20, 35, 60, 120 and 240 min) on recovery was studied at two levels of the relative centrifugal force (733 and 6597g). The effect of force on recovery was studied by centrifugation for 35 min at 117, 264, 733, 2932, 6597 and 14,191g. All soil moisture samples were chemically analysed. This study shows that drainage centrifugation offers a robust, reproducible and standardised way for determining solute concentrations in mobile soil moisture in silt loam subsoils. The centrifugal force, rather than centrifugation time, has a major effect on recovery. The maximum recovery for silt loams at field capacity is about 40%. Concentrations of most solutes are fairly constant with an increasing recovery, as most solutes, including nitrate, did not show a change in concentration with an increasing recovery.

  8. Purification of Peroxisomes and Mitochondria from Spinach Leaf by Percoll Gradient Centrifugation 1

    PubMed Central

    Schwitzguebel, Jean-Paul; Siegenthaler, Paul-André

    1984-01-01

    A procedure was developed to purify simultaneously peroxisomes and mitochondria from spinach (Spinacia oleracea L.) leaf under isoosmotic and low viscosity conditions. This method involved differential centrifugation and density gradient centrifugation on four layers of Percoll. Chlorophyll-free preparations of highly intact and active organelles were obtained and cross-contamination was negligible. Both organelles were stable for several hours, even if they remained in Percoll. Purified mitochondria were able to carry out the oxidation of different substrates with excellent respiratory control and ADP:O ratios. The method described in the present work was also suitable to purify mitochondria and peroxisomes from potato (Solanum tuberosum L.) tubers. PMID:16663685

  9. A test program to measure fluid mechanical whirl-excitation forces in centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Brennen, C. E.; Acosta, A. J.; Caughey, T. K.

    1980-01-01

    The details of a test program for the measurement of the unsteady forces on centrifugal impellers are discussed. Various hydrodynamic flows are identified as possible contributors to these destabilizing forces.

  10. Centripetal/Centrifugal Family Style of Families with Aggressive and Non-Aggressive Boys.

    ERIC Educational Resources Information Center

    Hurst, Duane F.; And Others

    Research on family interaction has characterized family style on centripetal and centrifugal dimensions, representing opposing natures with their own continua. Centripetal forces produce binding, or a prolonged process of separation of parent and child; centrifugal forces preciptate expelling, or hastened separation and premature autonomy. To…

  11. Propulsive force of Paramecium as revealed by the video centrifuge microscope.

    PubMed

    Kuroda, K; Kamiya, N

    1989-09-01

    Using the video centrifuge microscope we constructed, we observed the behavior of Paramecium cells in a solution of graded densities under centrifugal acceleration. Beyond 300g, they not only gather in the zone where the density is closest to theirs, but also orient themselves with their longitudinal axis parallel to the direction of centrifugation turning their anterior ends toward either centripetal or centrifugal direction. Since all of them retain still active swimming capacity, it is possible to calculate their propulsive force from the difference in density between theirs (1.04 g cm-3) and that of the upper or lower layer which they can reach. The propulsive force of single Paramecium cells thus obtained was calculated to be about 7 x 10(-4) dyn.

  12. Processing of semen by density gradient centrifugation selects spermatozoa with longer telomeres for assisted reproduction techniques.

    PubMed

    Yang, Qingling; Zhang, Nan; Zhao, Feifei; Zhao, Wanli; Dai, Shanjun; Liu, Jinhao; Bukhari, Ihtisham; Xin, Hang; Niu, Wenbing; Sun, Yingpu

    2015-07-01

    The ends of eukaryotic chromosomes contain specialized chromatin structures called telomeres, the length of which plays a key role in early human embryonic development. Although the effect of sperm preparation techniques on major sperm characteristics, such as concentration, motility and morphology have been previously documented, the possible status of telomere length and its relation with sperm preparation techniques is not well-known for humans. The aim of this study was to investigate the role of density gradient centrifugation in the selection of spermatozoa with longer telomeres for use in assisted reproduction techniques in 105 samples before and after sperm processing. After density gradient centrifugation, the average telomere length of the sperm was significantly longer (6.51 ± 2.54 versus 5.16 ± 2.29, P < 0.01), the average motile sperm rate was significantly higher (77.9 ± 11.8 versus 44.6 ± 11.2, P < 0.01), but average DNA fragmentation rate was significantly lower (11.1 ± 5.9 versus 25.9 ± 12.9, P < 0.01) compared with raw semen. Additionally, telomere length was positively correlated with semen sperm count (rs = 0.58; P < 0.01). In conclusion, density gradient centrifugation is a useful technique for selection of sperm with longer telomeres. Copyright © 2015 Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Does flowpath alteration by centrifugal force cause deviation from Darcy's law?

    NASA Astrophysics Data System (ADS)

    Nimmo, J. R.; Turturro, A. C.; MA, B.; Caputo, M. C.; Perkins, K. S.

    2016-12-01

    Though driving force much larger than gravity is unnatural, centrifugal force has proven useful for investigating flow in soil and rock. It affords practical measurement techniques, as well as a means of perturbation that can provide insights into the fundamentals of flow. Many centrifugally-driven flow experiments have been carried out in the USGS Menlo Park facility since 1980. Notable developments include the Steady-State Centrifuge (SSC) method and the Quasi-Steady Centrifuge (QSC) method for accurate measurements of unsaturated hydraulic properties over a wide range of water content. Centrifugal force can affect flowpaths in at least two ways: (1) deformation of pores by compression, and (2) distortion of air-water interfaces. Compression reduces the hydraulic conductivity K. We have measured this effect on saturated K of several core samples from several m depth. For forces over a 50X (factor-of-50) range, saturated K varied by as much as 10X. In unsaturated soil, the effect is less because much of the pore size reduction occurs in large pores and in air-filled space. A complication is that some portion of the compressional strain is elastic, and its rebound after centrifugation prevents easy determination of how much strain occurred at the time of measurement. Experiments with a linear displacement transducer inside a centrifuge bucket showed for a silty soil of massive structure that about one-third of the strain is elastic. Centrifugal force affords rigorous tests of Darcy's law. If flux measured at a single water content varies in direct proportion to driving force, Darcy's law is confirmed for the conditions tested. The SSC and QSC methods are ideally suited to this purpose as they allow great force variation with minimal effect on water content. Our tests at forces up to 1000 or more times normal gravity in a sandy soil at low water content, and in a porous sandstone (calcarenite) at intermediate water content, show strong agreement with Darcy's law. Further tests are needed because deviation would be more likely in cases such as higher water contents or greater heterogeneity. The observed good agreement, perhaps surprisingly, indicates that any force-caused alterations of the shape of air-water interfaces do not significantly affect unsaturated K.

  14. Rapid screening for plasmid DNA.

    PubMed

    Hughes, C; Meynell, G G

    1977-03-07

    A procedure is described for demonstrating plasmid DNA and its molecular weight, based on rate zonal centrifugation of unlabelled DNA in neutral sucrose gradients containing a low concentration of ethidium bromide. Each DNA species is then visualized as a discrete fluorescent band when the centrifuge tube is illuminated with ultra-violet light. Plasmids exist as closed circular and as relaxed circular molecules, which sediment separately, but during preparation of lysates, closed circular molecules are nicked so that each plasmid forms only a single band of relaxed circles within the gradient.

  15. Tropic responses of Phycomyces sporangiophores to gravitational and centrifugal stimuli.

    PubMed

    DENNISON, D S

    1961-09-01

    A low-speed centrifuge was used to study the tropic responses of Phycomyces sporangiophores in darkness to the stimulus of combined gravitational and centrifugal forces. If this stimulus is constant the response is a relatively slow tropic reaction, which persists for up to 12 hours. The response is accelerated by increasing the magnitude of the gravitational-centrifugal force. A wholly different tropic response, the transient response, is elicited by an abrupt change in the gravitational-centrifugal stimulus. The transient response has a duration of only about 6 min. but is characterized by a high bending speed (about 5 degrees /min.). An analysis of the distribution of the transient response along the growing zone shows that the active phase of the response has a distribution similar to that of the light sensitivity for the light-growth and phototropic responses. Experiments in which sporangiophores are centrifuged in an inert dense fluid indicate that the sensory mechanism of the transient response is closely related to the physical deformation of the growing zone caused by the action of the gravitational-centrifugal force on the sporangiophore as a whole. However, the response to a steady gravitational-centrifugal force is most likely not connected with this deformation, but is probably triggered by the shifting of regions or particles of differing density relative to one another inside the cell.

  16. Optical sensors based on the NiPc-CoPc composite films deposited by drop casting and under the action of centrifugal force

    NASA Astrophysics Data System (ADS)

    Fatima, Noshin; Ahmed, Muhammad M.; Karimov, Khasan S.; Ahmad, Zubair; Fariq Muhammad, Fahmi

    2017-06-01

    In this study, solution processed composite films of nickel phthalocyanine (NiPc) and cobalt phthalocyanine (CoPc) are deposited by drop casting and under centrifugal force. The films are deposited on surface-type inter-digitated silver electrodes on ceramic alumina substrates. The effects of illumination on the impedance and capacitance of the NiPc-CoPc composite samples are investigated. The samples deposited under centrifugal force show better conductivity than the samples deposited by drop casting technique. In terms of impedance and capacitance sensitivities the samples fabricated under centrifugal force are more sensitive than the drop casting samples. The values of impedance sensitivity ({S}z) are equal to (-1.83) {{M}}{{Ω }}\\cdot {{cm}}2/{mW} and (-5.365){{M}}{{Ω }}\\cdot {{cm}}2/{mW} for the samples fabricated using drop casting and under centrifugal force, respectively. Similarly, the values of capacitance sensitivity ({S}{{c}}) are equal to 0.083 {pF}\\cdot {{cm}}2/{mW} and 0.185 {pF}\\cdot {{cm}}2/{mW} for the samples fabricated by drop casting and under centrifugal force. The films deposited using the different procedures could potentially be viable for different operational modes (i.e., conductive or capacitive) of the optical sensors. Both experimental and simulated results are discussed. Project supported by the Center for Advanced Materials (CAM), Qatar University, Qatar.

  17. Respiratory Syncytial Virus Isolation by Combined Continuous Flow-Isopycnic Banding Centrifugation

    PubMed Central

    Cline, G. B.; Coates, Helen; Anderson, N. G.; Chanock, R. M.; Harris, W. W.

    1967-01-01

    A new zonal centrifuge rotor (B-IX) which combines continuous sample flow centrifugation with isopycnic banding has been used to isolate and concentrate respiratory syncytial virus from liter volumes of culture fluid. This isolation technique utilizes a sucrose density gradient to trap and isopycnically band the virus particles, and permits recovery of the particles from the rotor in an unaggregated condition. PMID:5621468

  18. Comparing cooling systems for the COBE 2991 cell separator used in the purification of human pancreatic islets of Langerhans.

    PubMed

    Adewola, A; Mage, R; Hansen, M; Barbaro, B; Mendoza-Elias, J; Harvat, T; Morel, P H; Oberholzer, J; Wang, Y

    2010-01-01

    Two different approaches of controlled cooling of the COBE 2991 cell-separator for islet purification were evaluated. The first method is the new Geneva COBE cooling system (GCCS), which consists of an electronically controlled liquid nitrogen injection system. The second is the University of Illinois at Chicago cooling system (UICCS), which consists of a specially designed "Cold Room" maintained at 1-8 C. For the GCCS, the mean temperatures of the gradient solutions were measured at the beginning and end of centrifugation were found to be 7 +/-0.7 C and 6.8 +/-0.6 C respectively. For the UICCS, the mean temperature of the gradients at the beginning and end of centrifugation were 4.7 +/-0.53 C and 7.03 C+/-0.91 C respectively. The presented COBE cooling systems can easily be adapted to a COBE 2991 cell-separator and are efficient in maintaining gradient solutions at a defined low temperature during centrifugation.

  19. Simulation of Shuttle launch G forces and acoustic loads using the NASA Ames Research Center 20G centrifuge

    NASA Technical Reports Server (NTRS)

    Shaw, T. L.; Corliss, J. M.; Gundo, D. P.; Mulenburg, G. M.; Breit, G. A.; Griffith, J. B.

    1994-01-01

    The high cost and long times required to develop research packages for space flight can often be offset by using ground test techniques. This paper describes a space shuttle launch and reentry simulating using the NASA Ames Research Center's 20G centrifuge facility. The combined G-forces and acoustic environment during shuttle launch and landing were simulated to evaluate the effect on a payload of laboratory rates. The launch G force and acoustic profiles are matched to actual shuttle launch data to produce the required G-forces and acoustic spectrum in the centrifuge test cab where the rats were caged on a free-swinging platform. For reentry, only G force is simulated as the aero-acoustic noise is insignificant compared to that during launch. The shuttle G-force profiles of launch and landing are achieved by programming the centrifuge drive computer to continuously adjust centrifuge rotational speed to obtain the correct launch and landing G forces. The shuttle launch acoustic environment is simulated using a high-power, low-frequency audio system. Accelerometer data from STS-56 and microphone data from STS-1 through STS-5 are used as baselines for the simulations. This paper provides a description of the test setup and the results of the simulation with recommendations for follow-on simulations.

  20. Centrifugal Size-Separation Sieve for Granular Materials

    NASA Technical Reports Server (NTRS)

    Walton, Otis (Inventor); Dreyer, Christopher (Inventor); Riedel, Edward (Inventor)

    2015-01-01

    A centrifugal sieve and method utilizes centrifugal force in rapidly-rotated cylindrical or conical screens as the primary body force contributing to size segregation. Within the centrifugal acceleration field, vibration and/or shearing flows are induced to facilitate size segregation and eventual separation of the fines from the coarse material. Inside a rotating cylindrical or conical screen, a separately-rotated screw auger blade can be used to transport material along the rotating cylinder or conical wall and to induce shearing in the material.

  1. Multiplexed single-molecule force spectroscopy using a centrifuge.

    PubMed

    Yang, Darren; Ward, Andrew; Halvorsen, Ken; Wong, Wesley P

    2016-03-17

    We present a miniature centrifuge force microscope (CFM) that repurposes a benchtop centrifuge for high-throughput single-molecule experiments with high-resolution particle tracking, a large force range, temperature control and simple push-button operation. Incorporating DNA nanoswitches to enable repeated interrogation by force of single molecular pairs, we demonstrate increased throughput, reliability and the ability to characterize population heterogeneity. We perform spatiotemporally multiplexed experiments to collect 1,863 bond rupture statistics from 538 traceable molecular pairs in a single experiment, and show that 2 populations of DNA zippers can be distinguished using per-molecule statistics to reduce noise.

  2. Multiplexed single-molecule force spectroscopy using a centrifuge

    PubMed Central

    Yang, Darren; Ward, Andrew; Halvorsen, Ken; Wong, Wesley P.

    2016-01-01

    We present a miniature centrifuge force microscope (CFM) that repurposes a benchtop centrifuge for high-throughput single-molecule experiments with high-resolution particle tracking, a large force range, temperature control and simple push-button operation. Incorporating DNA nanoswitches to enable repeated interrogation by force of single molecular pairs, we demonstrate increased throughput, reliability and the ability to characterize population heterogeneity. We perform spatiotemporally multiplexed experiments to collect 1,863 bond rupture statistics from 538 traceable molecular pairs in a single experiment, and show that 2 populations of DNA zippers can be distinguished using per-molecule statistics to reduce noise. PMID:26984516

  3. On the characteristics of centrifugal-reciprocating machines. [cryogenic coolers

    NASA Technical Reports Server (NTRS)

    Higa, W. H.

    1980-01-01

    A method of compressing helium gas for cryogenic coolers is presented which uses centrifugal force to reduce the forces on the connecting rod and crankshaft in the usual reciprocating compressor. This is achieved by rotating the piston-cylinder assembly at a speed sufficient for the centrifugal force on the piston to overcome the compressional force due to the working fluid. The rotating assembly is dynamically braked in order to recharge the working space with fluid. The intake stroke consists of decelerating the rotating piston-cylinder assembly and the exhaust stroke consists of accelerating the assembly.

  4. Purification and protein composition of endogenous rat viruses.

    PubMed

    Hlubinová, K; Prachar, J; Vrbenská, A; Matoska, J; Simkovic, D

    1984-01-01

    Endogenous retroviruses are not in the majority of cases the cause of any neoplasia, except for the laboratory conditions. As far as they might serve for the evolution of pathogenic retroviruses more attention should have been paid to them. In this paper we introduce some approaches to the purification of rat endogenous retroviruses to such a degree of purity that enabled satisfactory SDS-PAGE analysis of its structural proteins. Purities of samples obtained by usual purification methods, long-term isopycnic centrifugation at a high gravity force and velocity centrifugation are compared. Protein profile of rat endogenous virus in SDS-PAGE is compared with the ones of other retroviruses. For the first time the evidence was obtained for the striking similarity between electrophoretic protein profile of rat endogenous virus WERC and feline leukemia virus. The major structural proteins of rat endogenous retrovirus and feline leukemia virus cannot be distinguished even when resolution long gradient PAGE had been employed. The accordance of electrophoretic mobilities of major structural proteins in SDS-PAGE can indicate the relatedness of retroviruses.

  5. Determining the Effect of Centrifugal Force on the Desired Growth and Properties of PCPDTBT as p-Type Nanowires

    NASA Astrophysics Data System (ADS)

    Doris, Muhamad; Aziz, Fakhra; Alhummiany, Haya; Bawazeer, Tahani; Alsenany, Nourah; Mahmoud, Alaa; Zakaria, Rozalina; Sulaiman, Khaulah; Supangat, Azzuliani

    2017-01-01

    In this study, low-bandgap polymer poly{[4,4-bis(2-ethylhexyl)-cyclopenta-(2,1- b;3,4- b')dithiophen]-2,6-diyl- alt-(2,1,3-benzothiadiazole)-4,7-diyl} (PCPDTBT) nanostructures have been synthesized via a hard nanoporous alumina template of centrifugal process. Centrifuge has been used to infiltrate the PCPDTBT solution into the nanoporous alumina by varying the rotational speeds. The rotational speed of centrifuge is directly proportional to the infiltration force that penetrates into the nanochannels of the template. By varying the rotational speed of centrifuge, different types of PCPDTBT nanostructures are procured. Infiltration force created during the centrifugal process has been found a dominant factor in tuning the morphological, optical, and structural properties of PCPDTBT nanostructures. The field emission scanning electron microscopy (FESEM) images proved the formation of nanotubes and nanowires. The energy-dispersive X-ray spectroscope (EDX) analysis showed that the nanostructures were composed of PCPDTBT with complete dissolution of the template.

  6. Density gradient centrifugation of sperm from a subfertile stallion and effect of seminal plasma addition on fertility.

    PubMed

    Mari, Gaetano; Castagnetti, Carolina; Rizzato, Giovanni; Mislei, Beatrice; Iacono, Eleonora; Merlo, Barbara

    2011-06-01

    Stallions are not selected for fertility but for other criteria (pedigree, conformation, performances, progeny), therefore valuable but subfertile stallions with poor semen quality are frequently used in commercial breeding programs. The object of this study was to evaluate whether sperm selection through a silane-coated silica colloid gradient centrifugation, with or without the addition of seminal plasma of a high fertile stallion, could improve the pregnancy rates of an oligospermic valuable stallion in a commercial breeding program. In 2008 breeding season (experiment 1, n=104 mares), simple centrifugation and density gradient centrifugation of the sperm were compared. In 2009 and 2010 breeding seasons (experiment 2, n=125 mares), the effect of the addition of 5% seminal plasma to the extender after sperm selection was evaluated. In all mares deep horn uterine insemination was performed with 1 ml containing 50×10(6) morphologically normal progressive motile spermatozoa, 24-30 h after induction of ovulation with hCG. Pregnancy diagnosis by ultrasonography was performed 14 days following ovulation. Results showed a higher per cycle pregnancy rate (P>0.05) when sperm selection through a density gradient was used (62% vs. 42.3%, exp 1), while the addition of 5% seminal plasma did not influence the outcome (45.9% vs. 47.6%, exp 2) (P>0.05). An age-related decrease in the fertility of the stallion was observed when comparing the results from the different breeding seasons (P<0.05). In conclusion, sperm selection through a discontinuous density gradient enabled a normal per cycle pregnancy rate to be achieved from an oligospermic-subfertile stallion in a commercial breeding program, and no differences were observed regarding the addition of seminal plasma. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Centrifugal reciprocating compressor

    NASA Technical Reports Server (NTRS)

    High, W. H.

    1980-01-01

    Efficient compressor uses centrifugal force to compress gas. System incorporates two coupled dc motors, each driving separate centrifugal reciprocating-compressor assembly. Motors are synchronized to accelerate and decelerate alternately.

  8. Isolation of mitochondria from Saccharomyces cerevisiae using magnetic bead affinity purification

    PubMed Central

    Liao, Pin-Chao; Boldogh, Istvan R.; Siegmund, Stephanie E.

    2018-01-01

    Isolated mitochondria are widely used to study the function of the organelle. Typically, mitochondria are prepared using differential centrifugation alone or in conjunction with density gradient ultracentrifugation. However, mitochondria isolated using differential centrifugation contain membrane or organelle contaminants, and further purification of crude mitochondria by density gradient ultracentrifugation requires large amounts of starting material, and is time-consuming. Mitochondria have also been isolated by irreversible binding to antibody-coated magnetic beads. We developed a method to prepare mitochondria from budding yeast that overcomes many of the limitations of other methods. Mitochondria are tagged by insertion of 6 histidines (6xHis) into the TOM70 (Translocase of outer membrane 70) gene at its chromosomal locus, isolated using Ni-NTA (nickel (II) nitrilotriacetic acid) paramagnetic beads and released from the magnetic beads by washing with imidazole. Mitochondria prepared using this method contain fewer contaminants, and are similar in ultrastructure as well as protein import and cytochrome c oxidase complex activity compared to mitochondria isolated by differential centrifugation. Moreover, this isolation method is amenable to small samples, faster than purification by differential and density gradient centrifugation, and more cost-effective than purification using antibody-coated magnetic beads. Importantly, this method can be applied to any cell type where the genetic modification can be introduced by CRISPR or other methods. PMID:29698455

  9. Absence, Legitimacy and System Size.

    ERIC Educational Resources Information Center

    Gibson, R. Oliver

    As school systems grow both vertically and horizontally, they face forces tending both to unify (centripetal) and to disunify (centrifugal). A viable system growth involves a blend of both forces on both vertical and horizontal dimensions. It is often assumed that the disunifying impact of centrifugal forces is of such proportion that the…

  10. Effect of the radial buoyancy on a circular Couette flow

    NASA Astrophysics Data System (ADS)

    Meyer, Antoine; Yoshikawa, Harunori N.; Mutabazi, Innocent

    2015-11-01

    The effect of a radial temperature gradient on the stability of a circular Couette flow is investigated when the gravitational acceleration is neglected. The induced radial stratification of the fluid density coupled with the centrifugal acceleration generates radial buoyancy which is centrifugal for inward heating and centripetal for outward heating. This radial buoyancy modifies the Rayleigh discriminant and induces the asymmetry between inward heating and outward heating in flow behavior. The critical modes are axisymmetric and stationary for inward heating while for outward heating, they can be oscillatory axisymmetric or nonaxisymmetric depending on fluid diffusion properties, i.e., on the Prandtl number Pr. The dependence of the critical modes on Pr is explored for different values of the radius ratio of the annulus. The power input of the radial buoyancy is compared with other power terms. The critical frequency of the oscillatory axisymmetric modes is linked to the Brunt-Väisälä frequency due to the density stratification in the radial gravity field induced by the rotation. These modes are associated with inertial waves. The dispersion relation of the oscillatory axisymmetric modes is derived in the vicinity of the critical conditions. A weakly nonlinear amplitude equation with a forcing term is proposed to explain the domination of these axisymmetric oscillatory modes over the stationary centrifugal mode.

  11. Numerical analysis on the action of centrifuge force in magnetic fluid rotating shaft seals

    NASA Astrophysics Data System (ADS)

    Zou, Jibin; Li, Xuehui; Lu, Yongping; Hu, Jianhui

    2002-11-01

    The magnetic fluid seal is suitable for high-speed rotating shaft seal applications. Centrifuge force will have evident influence on magnetic fluid rotating shaft seals. The seal capacity of the rotating shaft seal can be improved or increased by some measures. Through hydrodynamic analysis the moving status of the magnetic fluid is worked out. By numerical method, the magnetic field and the isobars in the magnetic fluid of a seal device are computed. Then the influence of the centrifuge force on the magnetic fluid seal is calculated quantitatively.

  12. [The analytical setting of rotary speed of centrifuge rotor and centrifugation time in chemical, biochemical and microbiological practice].

    PubMed

    Zolotarev, K V

    2012-08-01

    The researchers happen to face with suspensions in their chemical, biochemical and microbiological practice. The suspensions are the disperse systems with solid dispersed phase and liquid dispersion medium and with dispersed phase particle size > 100 nm (10-7 m). Quite often the necessity occurs to separate solid particles from liquid. To use for this purpose the precipitation in gravitation field can make the process to progress too long. In this respect an effective mode is the precipitation in the field of centrifugal forces--the centrifugation. The rotary speed of centrifuge rotor and centrifugation time can be set analytically using regularities of general dynamics and hydrodynamics. To this effect, should be written and transformed the equation of First and Second Newton Laws for suspension particle being in the field of centrifugal forces and forces of resistance of liquid and vessel wall. The force of liquid resistance depends on particle motion condition in liquid. To determine the regimen the Archimedes and Reynolds numerical dimensionless criteria are to be applied. The article demonstrates the results of these transformations as analytical inverse ratio dependence of centrifugation time from rotary speed. The calculation of series of "rate-time" data permits to choose the optimal data pair on the assumption of centrifuge capacity and practical reasonability. The results of calculations are validated by actual experimental data hence the physical mathematical apparatus can be considered as effective one. The setting progress depends both from parameter (Reynolds criterion) and data series calculation. So, the most convenient way to apply this operation is the programming approach. The article proposes to use the program Microsoft Excel and VBA programming language for this purpose. The possibility to download the file from Internet to use it for fast solution is proposed.

  13. A wireless centrifuge force microscope (CFM) enables multiplexed single-molecule experiments in a commercial centrifuge.

    PubMed

    Hoang, Tony; Patel, Dhruv S; Halvorsen, Ken

    2016-08-01

    The centrifuge force microscope (CFM) was recently introduced as a platform for massively parallel single-molecule manipulation and analysis. Here we developed a low-cost and self-contained CFM module that works directly within a commercial centrifuge, greatly improving accessibility and ease of use. Our instrument incorporates research grade video microscopy, a power source, a computer, and wireless transmission capability to simultaneously monitor many individually tethered microspheres. We validated the instrument by performing single-molecule force shearing of short DNA duplexes. For a 7 bp duplex, we observed over 1000 dissociation events due to force dependent shearing from 2 pN to 12 pN with dissociation times in the range of 10-100 s. We extended the measurement to a 10 bp duplex, applying a 12 pN force clamp and directly observing single-molecule dissociation over an 85 min experiment. Our new CFM module facilitates simple and inexpensive experiments that dramatically improve access to single-molecule analysis.

  14. Apparatus and method for producing an artificial gravitational field

    NASA Technical Reports Server (NTRS)

    Mccanna, Jason (Inventor)

    1993-01-01

    An apparatus and method is disclosed for producing an artificial gravitational field in a spacecraft by rotating the same around a spin axis. The centrifugal force thereby created acts as an artificial gravitational force. The apparatus includes an engine which produces a drive force offset from the spin axis to drive the spacecraft towards a destination. The engine is also used as a counterbalance for a crew cabin for rotation of the spacecraft. Mass of the spacecraft, which may include either the engine or crew cabin, is shifted such that the centrifugal force acting on that mass is no longer directed through the center of mass of the craft. This off-center centrifugal force creates a moment that counterbalances the moment produced by the off-center drive force to eliminate unwanted rotation which would otherwise be precipitated by the offset drive force.

  15. The Role of the Upper Atmosphere for Dawn-Dusk and Interhemispheric Differences in the Coupled Magnetosphere-Ionosphere-Thermosphere System

    NASA Astrophysics Data System (ADS)

    Foerster, M.; Doornbos, E.; Haaland, S.

    2016-12-01

    Solar wind and IMF interaction with the geomagnetic field sets up a large-scale plasma circulation in the Earth's magnetosphere and the magnetically tightly connected ionosphere. The ionospheric ExB ion drift at polar latitudes accelerates the neutral gas as a nondivergent momentum source primarily in force balance with pressure gradients, while the neutral upper thermosphere circulation is essentially modified by apparent forces due to Earth's rotation (Coriolis and centrifugal forces) as well as advection and viscous forces. The apparent forces affect the dawn and dusk side asymmetrically, favouring a large dusk-side neutral wind vortex, while the non-dipolar portions of the Earth's magnetic field constitute significant hemispheric differences in magnetic flux and field configurations that lead to essential interhemispheric differences of the ion-neutral interaction. We present statistical studies of both the high-latitude ionospheric convection and the upper thermospheric circulation patterns based on measurements of the electron drift instrument (EDI) on board the Cluster satellites and by the accelerometer on board the CHAMP, GOCE, and Swarm spacecraft, respectively.

  16. Calibration of a rotating accelerometer gravity gradiometer using centrifugal gradients

    NASA Astrophysics Data System (ADS)

    Yu, Mingbiao; Cai, Tijing

    2018-05-01

    The purpose of this study is to calibrate scale factors and equivalent zero biases of a rotating accelerometer gravity gradiometer (RAGG). We calibrate scale factors by determining the relationship between the centrifugal gradient excitation and RAGG response. Compared with calibration by changing the gravitational gradient excitation, this method does not need test masses and is easier to implement. The equivalent zero biases are superpositions of self-gradients and the intrinsic zero biases of the RAGG. A self-gradient is the gravitational gradient produced by surrounding masses, and it correlates well with the RAGG attitude angle. We propose a self-gradient model that includes self-gradients and the intrinsic zero biases of the RAGG. The self-gradient model is a function of the RAGG attitude, and it includes parameters related to surrounding masses. The calibration of equivalent zero biases determines the parameters of the self-gradient model. We provide detailed procedures and mathematical formulations for calibrating scale factors and parameters in the self-gradient model. A RAGG physical simulation system substitutes for the actual RAGG in the calibration and validation experiments. Four point masses simulate four types of surrounding masses producing self-gradients. Validation experiments show that the self-gradients predicted by the self-gradient model are consistent with those from the outputs of the RAGG physical simulation system, suggesting that the presented calibration method is valid.

  17. Problem-Based Test: Replication of Mitochondrial DNA during the Cell Cycle

    ERIC Educational Resources Information Center

    Setalo, Gyorgy, Jr.

    2013-01-01

    Terms to be familiar with before you start to solve the test: cell cycle, generation time, S-phase, cell culture synchronization, isotopic pulse-chase labeling, density labeling, equilibrium density-gradient centrifugation, buoyant density, rate-zonal centrifugation, nucleoside, nucleotide, kinase enzymes, polymerization of nucleic acids,…

  18. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  19. Ion-exchange chromatography purification of extracellular vesicles.

    PubMed

    Kosanović, Maja; Milutinović, Bojana; Goč, Sanja; Mitić, Ninoslav; Janković, Miroslava

    2017-08-01

    Despite numerous studies, isolating pure preparations of extracellular vesicles (EVs) has proven challenging. Here, we compared ion-exchange chromatography (IEC) to the widely used sucrose density gradient (SDG) centrifugation method for the purification of EVs. EVs in bulk were isolated from pooled normal human amniotic fluid (AF) by differential centrifugation followed by IEC or sucrose density gradient separation. The purity of the isolated EVs was evaluated by electrophoresis and lectin blotting/immuno blotting to monitor the distribution of total proteins, different EVs markers, and selected N-glycans. Our data showed efficient separation of negatively charged EVs from other differently charged molecules, while comparative profiling of EVs using SDG centrifugation confirmed anion-exchange chromatography is advantageous for EV purification. Finally, although this IEC-based method was validated using AF, the approach should be readily applicable to isolation of EVs from other sources as well.

  20. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE PAGES

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-04-07

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Furthermore, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  1. Interactions between globular proteins and F-actin in isotonic saline solution.

    PubMed

    Lakatos, S; Minton, A P

    1991-10-05

    Solutions of each of three different globular proteins (cytochrome c, chromophorically labeled serum albumin, and chromophorically labeled aldolase), mixed with another unlabeled globular protein or with fibrous actin, were prepared in pH 8.0 Tris-HCl buffer containing 0.15 M NaCl. Each solution was centrifuged at low speed, at 5 degrees C, until unassociated globular protein in solution achieved sedimentation equilibrium. Individual absorbance gradients of both macrosolutes in the mixtures subsequent to centrifugation were obtained via optical scans of the centrifuge tubes at two wavelengths. The gradients of each macrosolute in mixtures of two globular proteins revealed no association of globular proteins under the conditions of these experiments, but perturbation of the gradients of serum albumin, aldolase, and cytochrome c in the presence of F-actin indicated association of all three globular proteins with F-actin. Perturbation of actin gradients in the presence of serum albumin and aldolase suggested partial depolymerization of the F-actin by the globular protein. Analysis of the data with a simple phenomenological model relating free globular protein, bound globular protein, and total actin concentration provided estimates of the respective equilibrium constants for association of serum albumin and aldolase with F-actin, under the conditions of these experiments, of the order of 0.1 microM-1.

  2. Influence of impeller and diffuser geometries on the lateral fluid forces of whirling centrifugal impeller

    NASA Technical Reports Server (NTRS)

    Ohashi, Hideo; Sakurai, Akira; Nishihama, Jiro

    1989-01-01

    Lateral fluid forces on two-dimensional centrifugal impellers, which whirl on a circular orbit in a vaneless diffuser, were reported. Experiments were further conducted for the cases in which a three-dimensional centrifugal impeller, a model of the boiler feed pump, whirls in vaneless and vaned diffusers. The influence of the clearance configuration between the casing and front shroud of the impeller was also investigated. The result indicated that the fluid dynamic interaction between the impeller and the guide vanes induces quite strong fluctuating fluid forces to the impeller, but nevertheless its influence on radial and tangential force components averaged over a whirling orbit is relatively small.

  3. Cause of kinematic differences during centrifugal and centripetal saccades.

    PubMed

    Koene, Ansgar R; Erkelens, Casper J

    2002-06-01

    Measurements of eye movements have shown that centrifugal movements (i.e. away from the primary position) have a lower maximum velocity and a longer duration than centripetal movements (i.e. toward the primary position) of the same size. In 1988 Pelisson proposed that these kinematic differences might be caused by differences in the neural command signals, oculomotor mechanics or a combination of the two. By using the result of muscle force measurements that were made in recent years (Orbit 1.8 Gaze mechanics simulation, Eidactics, San Francisco, 1999) we simulated the muscle forces during centrifugal and centripetal saccades. Based on these simulations we show that the cause of the kinematic differences between the centrifugal and centripetal saccades is the non-linear force-velocity relationship (i.e. muscle viscosity) of the muscles.

  4. Centrifuge separation effect on bacterial indicator reduction in dairy manure.

    PubMed

    Liu, Zong; Carroll, Zachary S; Long, Sharon C; Roa-Espinosa, Aicardo; Runge, Troy

    2017-04-15

    Centrifugation is a commonly applied separation method for manure processing on large farms to separate solids and nutrients. Pathogen reduction is also an important consideration for managing manure. Appropriate treatment reduces risks from pathogen exposure when manure is used as soil amendments or the processed liquid stream is recycled to flush the barn. This study investigated the effects of centrifugation and polymer addition on bacterial indicator removal from the liquid fraction of manure slurries. Farm samples were taken from a manure centrifuge processing system. There were negligible changes of quantified pathogen indicator concentrations in the low-solids centrate compared to the influent slurry. To study if possible improvements could be made to the system, lab scale experiments were performed investigating a range of g-forces and flocculating polymer addition. The results demonstrated that polymer addition had a negligible effect on the indicator bacteria levels when centrifuged at high g forces. However, the higher g force centrifugation was capable of reducing bacterial indicator levels up to two-log 10 in the liquid stream of the manure, although at speeds higher than typical centrifuge operations currently used for manure processing applications. This study suggests manure centrifuge equipment could be redesigned to provide pathogen reduction to meet emerging issues, such as zoonotic pathogen control. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. [A Modified Procedure to Isolate Synchronous Cells from Yeasts with Continuous Percoll Density Gradient and Their Raman Discrimination].

    PubMed

    Huang, Shu-shi; Lai, Jun-zhuo; Lu, Ming-qian; Cheng, Qin; Liao, Wei; Chen, Li-mei

    2015-08-01

    A modified procedure of Percoll density gradient centrifugation was developed to isolate and fractionate synchronous cells from stationary phase (sp) cultures of different yeast strains, as well as Raman spectra discrimination of single yeast cells was reported. About 1.75 mL Percoll solution in 2 mL polypropylene centrifugal tube was centrifuged at 19,320 g, 20 °C with an angle rotor for 15 min to form continuous densities gradient (1.00~1.31 g · mL(-1)), approximately 100 μL sample was overlaid onto the preformed continuous density gradient carefully, subsequently, centrifuged at 400 g for 60 min in a tabletop centrifuge equipped with a angle rotor at 25 °C. Yeast samples could be observed that the suspensions were separated into two cell fractions obviously. Both fractions of different yeast strains were respectively determined by differential interference contrast (DIC), phase contrast microscope and synchronous culture to distinguish their morphological and growth trait. The results showed that the lower fraction cells were unbudded, mostly unicellular, highly refractive, homogeneous and uniform in size, and represented growth characteristic synchronously; Their protoplasm had relatively high density, and contained significant concentrations of glycogen; all of which were accordant with description of quiescent yeast cells and G0 cells in previously published paper. It was shown that lower fraction was quiescent cells, synchronous G0 cells as well. A Raman tweezers setup was used to investigate the differences between two fractions, G0 cells and non G0 cells, at a single cell level. The result showed that both G0 cells and the non G0 cells had the same characteristic peaks corresponding biological macromolecules including proteins, carbohydrates and nucleic acids, but all characteristic peak intensities of G0 cells were higher than that of non G0 cells, implied that the macromolecular substance content of G0 cells was more higher. Principal component analysis (PCA) was performed between G0 cells and non G0 cells, the results showed that the chemical composition content among the synchronization G0 cells has less difference, and G0 cells were homogeneous but non G0 cells were heterogeneous, indicating single cell optical tweezers Raman spectroscopy could identify the synchronous and asynchronous cells. The modified method is feasible, economical and efficient highly. G0 synchronous cells of most yeast strains could be isolated by a modification of Percoll density gradient centrifugation.

  6. Aerodynamic stiffness of an unbound eccentric whirling centrifugal impeller with an infinite number of blades

    NASA Technical Reports Server (NTRS)

    Allaire, P. E.; Branagan, L. A.; Kocur, J. A.

    1982-01-01

    An unbounded eccentric centrifugal impeller with an infinite number of log spiral blades undergoing synchronous whirling in an incompressible fluid is considered. The forces acting on it due to coriolis forces, centripetal forces, changes in linear momentum, changes in pressure due to rotating and changes in pressure due to changes in linear momentum are evaluated.

  7. Effect of centrifugal forces on formation of secondary flow structures in a 180-degree curved artery model under pulsatile inflow conditions

    NASA Astrophysics Data System (ADS)

    Callahan, Shannon; Sajjad, Roshan; Bulusu, Kartik V.; Plesniak, Michael W.

    2013-11-01

    An experimental investigation of secondary flow structures within a 180-degree bent tube model of a curved artery was performed using phase-averaged, two-component, two-dimensional, particle image velocimetry (2C-2D PIV) under pulsatile inflow conditions. Pulsatile waveforms ranging from simple sinusoidal to physiological inflows were supplied. We developed a novel continuous wavelet transform algorithm (PIVlet 1.2) and applied it to vorticity fields for coherent secondary flow structure detection. Regime maps of secondary flow structures revealed new, deceleration-phase-dependent flow morphologies. The temporal instances where streamwise centrifugal forces dominated were associated with large-scale coherent structures, such as deformed Dean-, Lyne- and Wall-type (D-L-W) vortical structures. Magnitudes of streamwise and cross-stream centrifugal forces tend to balance during deceleration phases. Deceleration events were also associated with spatial reorganization and asymmetry in large-scale D-L-W secondary flow structures. Hence, the interaction between streamwise and cross-stream centrifugal forces that affects secondary flow morphologies is explained using a ``residual force'' parameter i.e., the difference in magnitudes of these forces. Supported by the NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.

  8. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, Richard F.

    1994-01-01

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation.

  9. Impact of Ficoll density gradient centrifugation on major and trace element concentrations in erythrocytes and blood plasma.

    PubMed

    Lu, Ying; Ahmed, Sultan; Harari, Florencia; Vahter, Marie

    2015-01-01

    Ficoll density gradient centrifugation is widely used to separate cellular components of human blood. We evaluated the suitability to use erythrocytes and blood plasma obtained from Ficoll centrifugation for assessment of elemental concentrations. We determined 22 elements (from Li to U) in erythrocytes and blood plasma separated by direct or Ficoll density gradient centrifugation, using inductively coupled plasma mass spectrometry. Compared with erythrocytes and blood plasma separated by direct centrifugation, those separated by Ficoll had highly elevated iodine and Ba concentration, due to the contamination from the Ficoll-Paque medium, and about twice as high concentrations of Sr and Mo in erythrocytes. On the other hand, the concentrations of Ca in erythrocytes and plasma were markedly reduced by the Ficoll separation, to some extent also Li, Co, Cu, and U. The reduced concentrations were probably due to EDTA, a chelator present in the Ficoll medium. Arsenic concentrations seemed to be lowered by Ficoll, probably in a species-specific manner. The concentrations of Mg, P, S, K, Fe, Zn, Se, Rb, and Cs were not affected in the erythrocytes, but decreased in plasma. Concentrations of Mn, Cd, and Pb were not affected in erythrocytes, but in plasma affected by EDTA and/or pre-analytical contamination. Ficoll separation changed the concentrations of Li, Ca, Co, Cu, As, Mo, I, Ba, and U in erythrocytes and blood plasma, Sr in erythrocytes, and Mg, P, S, K, Fe, Zn, Se, Rb and Cs in blood plasma, to an extent that will invalidate evaluation of deficiencies or excess intakes. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. Hydraulic forces on a centrifugal impeller undergoing synchronous whirl

    NASA Technical Reports Server (NTRS)

    Allaire, P. E.; Sato, C. J.; Branagan, L. A.

    1984-01-01

    High speed centrifugal rotating machinery with large vibrations caused by aerodynamic forces on impellers was examined. A method to calculate forces in a two dimensional orbiting impeller in an unbounded fluid with nonuniform entering flow was developed. A finite element model of the full impeller is employed to solve the inviscid flow equations. Five forces acting on the impeller are: Coriolis forces, centripetal forces, changes in linear momentum, changes in pressure due to rotation and pressure changes due to linear momentum. Both principal and cross coupled stiffness coefficients are calculated for the impeller.

  11. Flow shear stabilization of rotating plasmas due to the Coriolis effect.

    PubMed

    Haverkort, J W; de Blank, H J

    2012-07-01

    A radially decreasing toroidal rotation frequency can have a stabilizing effect on nonaxisymmetric magnetohydrodynamic (MHD) instabilities. We show that this is a consequence of the Coriolis effect that induces a restoring pressure gradient force when plasma is perturbed radially. In a rotating cylindrical plasma, this Coriolis-pressure effect is canceled by the centrifugal effect responsible for the magnetorotational instability. In a magnetically confined toroidal plasma, a large aspect ratio expansion shows that only half of the effect is canceled. This analytical result is confirmed by numerical computations. When the plasma rotates faster toroidally in the core than near the edge, the effect can contribute to the formation of transport barriers by stabilizing MHD instabilities.

  12. Isolation of Intact Chloroplasts from Euglena gracilis by Zonal Centrifugation 1

    PubMed Central

    Vasconcelos, Aurea; Pollack, Marilyn; Mendiola, Leticia R.; Hoffmann, H.-P.; Brown, D. H.; Price, C. A.

    1971-01-01

    Chloroplasts were separated from Euglena gracilis by zonal centrifugation at low speed in density gradients of Ficoll or dextran. The chloroplasts were intact by the criteria of ultrastructure and their content of ribulose diphosphate carboxylase and soluble protein. The chloroplasts also contained ribosomes and ribosomal RNA uncontaminated by the corresponding cytoplasmic particles. Images PMID:16657599

  13. Axial forces in centrifugal compressor couplings

    NASA Astrophysics Data System (ADS)

    Ivanov, A. N.; Ivanov, N. M.; Yun, V. K.

    2017-08-01

    The article presents the results of the theoretical and experimental investigation of axial forces arising in the toothed and plate couplings of centrifugal compressor shaft lines. Additional loads on the thrust bearing are considered that can develop in the toothed couplings as a result of coupled rotors misalignment. Design relationships to evaluate the level of axial forces and recommendations for their reduction in the operating conditions are given.

  14. Purification of lymphocystis disease virus (LDV) grown in tissue culture. Evidences for the presence of two types of viral particles.

    PubMed

    Robin, J; Berthiaume, L

    1981-12-01

    Lymphocystis disease virus was highly purified from host cells by precipitation with PEG-6000 and isopycnic centrifugation in a metrizamide gradient. Metrizamide gradient centrifugation produce two distinct bands at equilibrium. As calculated from reconstruction experiments, only 4 and 0.3% respectively of the host DNA and the host proteins were recovered at the position of the bands. The final recovery of infectivity was about 41%. Electron microscopy of the bands showed two types of particles: small and dense particles measuring 100-150 nm and lymphocystis virions that measured about 300-350 nm in diameter.

  15. Fluid Redistribution and Heart Rate in Humans During Whole-Body Tilting, G(z) Centrifugation, and Lower Body Negative Pressure

    NASA Technical Reports Server (NTRS)

    Watenpaugh, D. E.; Breit, G. A.; Ballard, R. E.; Murthy, G.; Hargens, A. R.

    1994-01-01

    Gravity creates blood pressure gradients which redistribute body fluids towards the feet. Positive G(z) centrifugation and lower body negative pressure (LBNP) have been proposed to simulate these and other effects of gravity during long-term existence in microgravity. We hypothesized that the magnitude of upper-to-lower body fluid redistribution would increase according to the following order: short-arm centrifugation (SAC), long-arm centrifugation (LAC), head-up tilt (HUT), and LBNP. To test this hypothesis, we employed strain gauge plethysmography of the neck, thigh and calf during HUT and supine SAC and LAC up to lG(z) at the feet, and during supine LBNP to 100 mm Hg. Supine 100 mm Hg LBNP generates footward force and produces transmural blood pressures in the foot approximately equal to 1 G(z) (90 deg) HUT. Heart rate was measured via cardiotachometry. Control measurements were made while supine. SAC and LAC elicited similar increases in thigh volume at 1 G(z) (2.3 +/- 0.4 and 2.1 +/- 0.1%, respectively; mean +/- se, n greater than or equal to 7). At 100 mm Hg LBNP, thigh volume increased (3.4 +/- 0.3%) significantly more than during l G(z) centrifugation (p less than 0.05). Surprisingly, due to a paradoxical 0.6% reduction of thigh volume between 0.8 and 1.0 G(z) HUT, thigh volume was increased only 0.6 +/- 0.3% at 1 G(z) HUT. The calf demonstrated similar, although less definitive, responses to the various gravitational stimuli. Neck volume tended to decrease less during HUT than during the other stimuli. Heart rate increased similarly during HUT (18 +/- 2 beats/min) and LAC (12 +/- 2 beats/min), and exhibited still greater elevation during LBNP (29 +/- 4 beats/min), yet did not increase during SAC. These results suggest upright posture activates mechanisms that counteract footward fluid redistribution which are not activated during supine applications of simulated gravity. LAC more closely approximated effects of normal gravity (HUT) than LBNP. Therefore, when considering LBNP to simulate gravity, these findings support efforts to reduce the cardiovascular stress imposed by LBNP, while preserving the gravity-like force generated by LBNP.

  16. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, R.F.

    1994-02-15

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation. 4 figures.

  17. Fabrication of silk fibroin film using centrifugal casting technique for corneal tissue engineering.

    PubMed

    Lee, Min Chae; Kim, Dong-Kyu; Lee, Ok Joo; Kim, Jung-Ho; Ju, Hyung Woo; Lee, Jung Min; Moon, Bo Mi; Park, Hyun Jung; Kim, Dong Wook; Kim, Su Hyeon; Park, Chan Hum

    2016-04-01

    Films prepared from silk fibroin have shown potential as biomaterials in tissue engineering applications for the eye. Here, we present a novel process for fabrication of silk fibroin films for corneal application. In this work, fabrication of silk fibroin films was simply achieved by centrifugal force. In contrast to the conventional dry casting method, we carried out the new process in a centrifuge with a rotating speed of 4000 rpm, where centrifugal force was imposed on an aluminum tube containing silk fibroin solution. In the present study, we also compared the surface roughness, mechanical properties, transparency, and cell proliferation between centrifugal and dry casting method. In terms of surface morphology, films fabricated by the centrifugal casting have less surface roughness than those by the dry casting. For elasticity and transparency, silk fibroin films obtained from the centrifugal casting had favorable results compared with those prepared by dry casting. Furthermore, primary human corneal keratocytes grew better in films prepared by the centrifugal casting. Therefore, our results suggest that this new fabrication process for silk fibroin films offers important potential benefits for corneal tissue regeneration. © 2015 Wiley Periodicals, Inc.

  18. Numerical and experimental analysis of the sedimentation of spherical colloidal suspensions under centrifugal force

    NASA Astrophysics Data System (ADS)

    Antonopoulou, Evangelia; Rohmann-Shaw, Connor F.; Sykes, Thomas C.; Cayre, Olivier J.; Hunter, Timothy N.; Jimack, Peter K.

    2018-03-01

    Understanding the sedimentation behaviour of colloidal suspensions is crucial in determining their stability. Since sedimentation rates are often very slow, centrifugation is used to expedite sedimentation experiments. The effect of centrifugal acceleration on sedimentation behaviour is not fully understood. Furthermore, in sedimentation models, interparticle interactions are usually omitted by using the hard-sphere assumption. This work proposes a one-dimensional model for sedimentation using an effective maximum volume fraction, with an extension for sedimentation under centrifugal force. A numerical implementation of the model using an adaptive finite difference solver is described. Experiments with silica suspensions are carried out using an analytical centrifuge. The model is shown to be a good fit with experimental data for 480 nm spherical silica, with the effects of centrifugation at 705 rpm studied. A conversion of data to Earth gravity conditions is proposed, which is shown to recover Earth gravity sedimentation rates well. This work suggests that the effective maximum volume fraction accurately captures interparticle interactions and provides insights into the effect of centrifugation on sedimentation.

  19. Novel design and fabrication of a microcentrifuge for biomedical and biochemical applications

    NASA Astrophysics Data System (ADS)

    Yan, Dong; Xu, Bai; Castracane, James

    2003-01-01

    In this paper, modeling and simulation of a novel micro-centrifuge for biomedical and biochemical applications is described. The micro-centrifuge that we designed can work not only as a shaker but also as a detector of cell growth, which has great potential applications in bioanalysis. The initial design contains four channels for mixing or collecting of samples by centrifugal force. The rotor, the key component of this device, is actuated using electrostatic force. There are four electrodes on the substrate to actuate the micro-centrifuge rotation around the X-axis (lateral in plane) and the Y-axis (vertical in plane) respectively, and eight pairs of comb drives are used to actuate the micro-centrifuge rotation around the Z-axis (perpendicular to the XY plane). The multiple axis actuation design makes it very flexible to control the micro-centrifuge. Because of its small feature size, the cost of the reagent used for the micro-centrifuge will be greatly reduced. An array of micro-centrifuges will be designed to achieve a fast cycling time. A Finite Element Analysis (FEA) has been completed to analyze the static and dynamic performance of the micro-centrifuge, such as the natural frequencies, tilt angle, and driving voltage. A novel fabrication process using SOI technology has been proposed which is now being developed.

  20. Radial Flow Effects On A Retreating Rotor Blade

    DTIC Science & Technology

    2014-05-01

    blades which are subject to the coupled effects of reactive centrifugal and Coriolis forces unique to the rotating environment. These forces are...coupled effects of centrifugal and Coriolis forces in the rotating environment add more complexity to the flow characteristics [96]. McCroskey’s [74...disk will definitely cause some non-linear effects on the radial velocity profile. These effects are not investigated in this study. The next of

  1. Evolutionary Optimization of Centrifugal Nozzles for Organic Vapours

    NASA Astrophysics Data System (ADS)

    Persico, Giacomo

    2017-03-01

    This paper discusses the shape-optimization of non-conventional centrifugal turbine nozzles for Organic Rankine Cycle applications. The optimal aerodynamic design is supported by the use of a non-intrusive, gradient-free technique specifically developed for shape optimization of turbomachinery profiles. The method is constructed as a combination of a geometrical parametrization technique based on B-Splines, a high-fidelity and experimentally validated Computational Fluid Dynamic solver, and a surrogate-based evolutionary algorithm. The non-ideal gas behaviour featuring the flow of organic fluids in the cascades of interest is introduced via a look-up-table approach, which is rigorously applied throughout the whole optimization process. Two transonic centrifugal nozzles are considered, featuring very different loading and radial extension. The use of a systematic and automatic design method to such a non-conventional configuration highlights the character of centrifugal cascades; the blades require a specific and non-trivial definition of the shape, especially in the rear part, to avoid the onset of shock waves. It is shown that the optimization acts in similar way for the two cascades, identifying an optimal curvature of the blade that both provides a relevant increase of cascade performance and a reduction of downstream gradients.

  2. Laminar flow effects in the coil planet centrifuge

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1984-01-01

    The coil planet centrifuge designed by Ito employs flow of a single liquid phase, through a rotating coiled tube in a centrifugal force field, to provide a separation of particles based on sedimentation rates. Mathematical solutions are derived for the linear differential equations governing particle behavior in the coil planet centrifuge device. These solutions are then applied as the basis of a model for optimizing particle separations.

  3. Vibration analysis of large centrifugal pump rotors

    NASA Astrophysics Data System (ADS)

    Y Zhao, W.; Ge, J. G.; Ma, D.; Li, C. M.; Bao, S. B.

    2013-12-01

    Through the critical speed of centrifugal pumps, internal flow field and the force of the impeller, we analyze centrifugal pump vibration. Using finite element analysis software ANSYS to calculate the natural frequency of the rotor system and the critical speed; with the help of the Fluent software to simulate pump internal flow field, we conclude that speed increase will not cause intense vibration of the fluid in the pump. Using unsteady numerical simulation we discovered that in an impeller suffering transient radial force cyclical change periodically, as well as the frequency size determined by the product of the impeller speed and number of blades, resonance phenomena should make impeller to transient radial force frequency. If wanting to avoid pump resonance when it is running away, the transient radial force frequency should avoid the frequency range which can cause resonance.

  4. Resistance of mature Arabidopsis plants to mechanical deformation in relation to g-force during development

    NASA Technical Reports Server (NTRS)

    Brown, A. H.

    1983-01-01

    Arabidopsis plants were grown in centrifuge tubes under well standardized culture conditions. Each plant was subjected to centrifugation (roots out) for 10 min at one of a series of centripetal forces between 7 and 390g. No deformation was observed in plants centrifuged at less than 35g. An 'average' degree of deformation was attained at about 60g. All plants exposed to more than 95g were maximally deformed but none was broken nor otherwise damaged irreversibly even at 390g. In every case new shoot growth continued normally after the centrifugation. A plant population grown on horizontal clinostats (0.5 rpm) under culture conditions exactly the same as for the upright plants responded to centrifugation stress in a way that was not substantially different from the response pattern of the plants cultured upright at 1g.

  5. Large-scale and highly efficient synthesis of micro- and nano-fibers with controlled fiber morphology by centrifugal jet spinning for tissue regeneration

    NASA Astrophysics Data System (ADS)

    Ren, Liyun; Pandit, Vaibhav; Elkin, Joshua; Denman, Tyler; Cooper, James A.; Kotha, Shiva P.

    2013-02-01

    PLLA fibrous tissue scaffolds with controlled fiber nanoscale surface roughness are fabricated with a novel centrifugal jet spinning process. The centrifugal jet spinning technique is a highly efficient synthesis method for micron- to nano-sized fibers with a production rate up to 0.5 g min-1. During the centrifugal jet spinning process, a polymer solution jet is stretched by the centrifugal force of a rotating chamber. By engineering the rheological properties of the polymer solution, solvent evaporation rate and centrifugal force that are applied on the solution jet, polyvinylpyrrolidone (PVP) and poly(l-lactic acid) (PLLA) composite fibers with various diameters are fabricated. Viscosity measurements of polymer solutions allowed us to determine critical polymer chain entanglement limits that allow the generation of continuous fiber as opposed to beads or beaded fibers. Above a critical concentration at which polymer chains are partially or fully entangled, lower polymer concentrations and higher centrifugal forces resulted in thinner fibers. Etching of PVP from the PLLA-PVP composite fibers doped with increasing PVP concentrations yielded PLLA fibers with increasing nano-scale surface roughness and porosity, which increased the fiber hydrophilicity dramatically. Scanning electron micrographs of the etched composite fibers suggest that PVP and PLLA were co-contiguously phase separated within the composite fibers during spinning and nano-scale roughness features were created after the partial etching of PVP. To study the tissue regeneration efficacy of the engineered PLLA fiber matrix, human dermal fibroblasts are used to simulate partial skin graft. Fibers with increased PLLA surface roughness and porosity demonstrated a trend towards higher cell attachment and proliferation.PLLA fibrous tissue scaffolds with controlled fiber nanoscale surface roughness are fabricated with a novel centrifugal jet spinning process. The centrifugal jet spinning technique is a highly efficient synthesis method for micron- to nano-sized fibers with a production rate up to 0.5 g min-1. During the centrifugal jet spinning process, a polymer solution jet is stretched by the centrifugal force of a rotating chamber. By engineering the rheological properties of the polymer solution, solvent evaporation rate and centrifugal force that are applied on the solution jet, polyvinylpyrrolidone (PVP) and poly(l-lactic acid) (PLLA) composite fibers with various diameters are fabricated. Viscosity measurements of polymer solutions allowed us to determine critical polymer chain entanglement limits that allow the generation of continuous fiber as opposed to beads or beaded fibers. Above a critical concentration at which polymer chains are partially or fully entangled, lower polymer concentrations and higher centrifugal forces resulted in thinner fibers. Etching of PVP from the PLLA-PVP composite fibers doped with increasing PVP concentrations yielded PLLA fibers with increasing nano-scale surface roughness and porosity, which increased the fiber hydrophilicity dramatically. Scanning electron micrographs of the etched composite fibers suggest that PVP and PLLA were co-contiguously phase separated within the composite fibers during spinning and nano-scale roughness features were created after the partial etching of PVP. To study the tissue regeneration efficacy of the engineered PLLA fiber matrix, human dermal fibroblasts are used to simulate partial skin graft. Fibers with increased PLLA surface roughness and porosity demonstrated a trend towards higher cell attachment and proliferation. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr33423f

  6. Effects of temperature distribution and elastic properties of materials on gas-turbine-disk stresses

    NASA Technical Reports Server (NTRS)

    Holms, Arthur G; Faldetta, Richard D

    1947-01-01

    Calculations were made to determine the influence of changes in temperature distribution and in elastic material properties on calculated elastic stresses for a typical gas-turbine disk. Severe temperature gradients caused thermal stresses of sufficient magnitude to reduce the operating safety of the disk. Small temperature gradients were found to be desirable because they produced thermal stresses that subtracted from the centrifugal stresses in the region of the rim. The thermal gradients produced a tendency for a severe stress condition to exist near the rim but this stress condition could be shifted away from the region of blade attachment by altering the temperature distribution. The investigation of elastic material properties showed that centrifugal stresses are slightly affected by changes in modulus of elasticity, but that thermal stresses are approximately proportional to modulus of elasticity and to coefficient of thermal expansion.

  7. Isolating Lysosomes from Rat Liver.

    PubMed

    Pryor, Paul R

    2016-04-01

    This protocol describes the generation of a fraction enriched in lysosomes from rat liver. The lysosomes are rapidly isolated using density-gradient centrifugation with gradient media that retain the osmolarity of the lysosomes such that they are functional and can be used in in vitro assays. © 2016 Cold Spring Harbor Laboratory Press.

  8. Retained functional integrity of bull spermatozoa after double freezing and thawing using PureSperm density gradient centrifugation.

    PubMed

    Maxwell, W M C; Parrilla, I; Caballero, I; Garcia, E; Roca, J; Martinez, E A; Vazquez, J M; Rath, D

    2007-10-01

    The main aim of this study was to compare the motility and functional integrity of bull spermatozoa after single and double freezing and thawing. The viability and morphological integrity of spermatozoa selected by PureSperm density gradient centrifugation after cryopreservation of bovine semen in two commercial extenders (Experiment 1) and the function of bull spermatozoa before and after a second freezing and thawing assisted by PureSperm selection (Experiment 2) were examined. On average, 35.8 +/- 12.1% of sperm loaded onto the PureSperm density gradient were recovered after centrifugation. In Experiment 1, post-thaw motility and acrosome integrity were higher for spermatozoa frozen in Tris-egg yolk extender than in AndroMed, whether the assessments were made immediately after thawing [80.4 +/- 12.7 vs 47.6 +/- 19.0% motile and 78.8 +/- 8.3 vs 50.1 +/- 19.5% normal apical ridge (NAR), p < 0.05] or after preparation on the gradient (83.3 +/- 8.6 vs 69.4 +/- 15.9% motile and 89.5 +/- 7.2 vs 69.1 +/- 11.4% NAR, p < 0.05). For semen frozen in Tris-egg yolk extender, selection on the PureSperm gradient did not influence total motility but significantly improved the proportion of acrosome-intact spermatozoa. After the gradient, both the total motility and percentage of normal acrosomes increased for spermatozoa frozen in AndroMed (Minitüb Tiefenbach, Germany). In Experiment 2, there was no difference in sperm motility after the first and second freeze-thawing (82.9 +/- 12.7 vs 68.8 +/- 18.7%). However, the proportion of acrosome-intact spermatozoa was significantly improved by selection through the PureSperm gradient, whether measured by phase contrast microscopy (78.9 +/- 9.7 vs 90.4 +/- 4.0% NAR, p < 0.05) or flow cytometry (53.4 +/- 11.7 vs 76.3 +/- 6.0% viable acrosome-intact spermatozoa, p < 0.001). The improvement in the percentage of spermatozoa with normal acrosomes was maintained after resuspension in the cooling extender and cooling to 4 degrees C (88.2 +/- 6.2) and after re-freezing and thawing (83.6 +/- 6.56% NAR). However, flow cytometric assessment of the sperm membranes revealed a decline in the percentage of viable spermatozoa with intact membranes after the second freezing and thawing compared with after gradient centrifugation (76.3 +/- 6.0% vs 46.6 +/- 6.6%, p < 0.001) to levels equivalent to those obtained after the first round of freeze-thawing (53.4 +/- 11.7% viable acrosome-intact spermatozoa). Sperm movement characteristics assessed by computer-assisted analysis were unaffected in the population selected on the PureSperm gradients but declined after cooling of the selected and extended spermatozoa to 4 degrees C. There was no further change in these kinematic measurements after the cooled spermatozoa had undergone the second round of freeze-thawing. These results demonstrate that bull semen can be frozen and thawed, followed by a second freeze-thawing cycle of a population of spermatozoa selected by PureSperm, with retained motility and functional integrity. This points to the possibility of using double frozen spermatozoa in bovine artificial insemination programmes and to the potential benefits of PureSperm density gradient centrifugation for the application of cryopreserved bull spermatozoa to other biotechnological procedures such as flow cytometric sex sorting followed by re-freezing and thawing.

  9. View of new centrifuge at Flight Acceleration Facility

    NASA Technical Reports Server (NTRS)

    1966-01-01

    View of the new centrifuge at the Manned Spacecraft Center (MSC), located in the Flight Acceleration Facility, bldg 29. The 50-ft. arm can swing the three man gondola to create g-forces astronauts will experience during controlled flight and during reentry. The centrifuge was designed primarily for training Apollo astronauts.

  10. Geometric Energy Derivatives at the Complete Basis Set Limit: Application to the Equilibrium Structure and Molecular Force Field of Formaldehyde.

    PubMed

    Morgan, W James; Matthews, Devin A; Ringholm, Magnus; Agarwal, Jay; Gong, Justin Z; Ruud, Kenneth; Allen, Wesley D; Stanton, John F; Schaefer, Henry F

    2018-03-13

    Geometric energy derivatives which rely on core-corrected focal-point energies extrapolated to the complete basis set (CBS) limit of coupled cluster theory with iterative and noniterative quadruple excitations, CCSDTQ and CCSDT(Q), are used as elements of molecular gradients and, in the case of CCSDT(Q), expansion coefficients of an anharmonic force field. These gradients are used to determine the CCSDTQ/CBS and CCSDT(Q)/CBS equilibrium structure of the S 0 ground state of H 2 CO where excellent agreement is observed with previous work and experimentally derived results. A fourth-order expansion about this CCSDT(Q)/CBS reference geometry using the same level of theory produces an exceptional level of agreement to spectroscopically observed vibrational band origins with a MAE of 0.57 cm -1 . Second-order vibrational perturbation theory (VPT2) and variational discrete variable representation (DVR) results are contrasted and discussed. Vibration-rotation, anharmonicity, and centrifugal distortion constants from the VPT2 analysis are reported and compared to previous work. Additionally, an initial application of a sum-over-states fourth-order vibrational perturbation theory (VPT4) formalism is employed herein, utilizing quintic and sextic derivatives obtained with a recursive algorithmic approach for response theory.

  11. Faecal Parasitology: Concentration Methodology Needs to be Better Standardised

    PubMed Central

    Manser, Monika M.; Saez, Agatha Christie Santos; Chiodini, Peter L.

    2016-01-01

    Aim To determine whether variation in the preservative, pore size of the sieve, solvent, centrifugal force and centrifugation time used in the Ridley-Allen Concentration method for examining faecal specimens for parasite stages had any effect on their recovery in faecal specimens. Methods A questionnaire was sent to all participants in the UK NEQAS Faecal Parasitology Scheme. The recovery of parasite stages was compared using formalin diluted in water or formalin diluted in saline as the fixative, 3 different pore sizes of sieve, ether or ethyl acetate as a solvent, 7 different centrifugal forces and 6 different centrifugation times according to the methods described by participants completing the questionnaire. Results The number of parasite stages recovered was higher when formalin diluted in water was used as fixative, a smaller pore size of sieve was used, ethyl acetate along with Triton X 100 was used as a solvent and a centrifugal force of 3,000 rpm for 3 minutes were employed. Conclusions This study showed that differences in methodology at various stages of the concentration process affect the recovery of parasites from a faecal specimen and parasites present in small numbers could be missed if the recommended methodology is not followed. PMID:27073836

  12. Research for the Fluid Field of the Centrifugal Compressor Impeller in Accelerating Startup

    NASA Astrophysics Data System (ADS)

    Li, Xiaozhu; Chen, Gang; Zhu, Changyun; Qin, Guoliang

    2013-03-01

    In order to study the flow field in the impeller in the accelerating start-up process of centrifugal compressor, the 3-D and 1-D transient accelerated flow governing equations along streamline in the impeller of the centrifugal compressor are derived in detail, the assumption of pressure gradient distribution is presented, and the solving method for 1-D transient accelerating flow field is given based on the assumption. The solving method is achieved by programming and the computing result is obtained. It is obtained by comparison that the computing method is met with the test result. So the feasibility and effectiveness for solving accelerating start-up problem of centrifugal compressor by the solving method in this paper is proven.

  13. Modified smoothed particle hydrodynamics (MSPH) for the analysis of centrifugally assisted TiC-Fe-Al2O3 combustion synthesis

    NASA Astrophysics Data System (ADS)

    Hassan, M. A.; Mahmoodian, Reza; Hamdi, M.

    2014-01-01

    A modified smoothed particle hydrodynamic (MSPH) computational technique was utilized to simulate molten particle motion and infiltration speed on multi-scale analysis levels. The radial velocity and velocity gradient of molten alumina, iron infiltration in the TiC product and solidification rate, were predicted during centrifugal self-propagating high-temperature synthesis (SHS) simulation, which assisted the coating process by MSPH. The effects of particle size and temperature on infiltration and solidification of iron and alumina were mainly investigated. The obtained results were validated with experimental microstructure evidence. The simulation model successfully describes the magnitude of iron and alumina diffusion in a centrifugal thermite SHS and Ti + C hybrid reaction under centrifugal acceleration.

  14. Modified smoothed particle hydrodynamics (MSPH) for the analysis of centrifugally assisted TiC-Fe-Al2O3 combustion synthesis

    PubMed Central

    Hassan, M. A.; Mahmoodian, Reza; Hamdi, M.

    2014-01-01

    A modified smoothed particle hydrodynamic (MSPH) computational technique was utilized to simulate molten particle motion and infiltration speed on multi-scale analysis levels. The radial velocity and velocity gradient of molten alumina, iron infiltration in the TiC product and solidification rate, were predicted during centrifugal self-propagating high-temperature synthesis (SHS) simulation, which assisted the coating process by MSPH. The effects of particle size and temperature on infiltration and solidification of iron and alumina were mainly investigated. The obtained results were validated with experimental microstructure evidence. The simulation model successfully describes the magnitude of iron and alumina diffusion in a centrifugal thermite SHS and Ti + C hybrid reaction under centrifugal acceleration. PMID:24430621

  15. Modified smoothed particle hydrodynamics (MSPH) for the analysis of centrifugally assisted TiC-Fe-Al2O3 combustion synthesis.

    PubMed

    Hassan, M A; Mahmoodian, Reza; Hamdi, M

    2014-01-16

    A modified smoothed particle hydrodynamic (MSPH) computational technique was utilized to simulate molten particle motion and infiltration speed on multi-scale analysis levels. The radial velocity and velocity gradient of molten alumina, iron infiltration in the TiC product and solidification rate, were predicted during centrifugal self-propagating high-temperature synthesis (SHS) simulation, which assisted the coating process by MSPH. The effects of particle size and temperature on infiltration and solidification of iron and alumina were mainly investigated. The obtained results were validated with experimental microstructure evidence. The simulation model successfully describes the magnitude of iron and alumina diffusion in a centrifugal thermite SHS and Ti + C hybrid reaction under centrifugal acceleration.

  16. Strength analysis of an aircraft turbo-compressor engine turbine disc

    NASA Astrophysics Data System (ADS)

    Klimko, Marek

    2017-09-01

    This article deals with a strength analysis of a gas turbine rotor disc of the concrete type of an aircraft turbo-compressor engine (ATCE). The introductory part is dedicated to a basic description of the given engine, including the main technical parameters entering the calculation. The calculation is carried out by the finite difference method. This method allows to determine the tension of a generally shaped disc, which is affected by centrifugal forces of its weight, external load and heat stress caused by the difference of thermal gradients along the disc radius. The result of calculations are dependencies of the most important parameters, such as the reduced stress, radial stress, or the safety coefficient along the disc radius.

  17. The growth of homogeneous semiconductor crystals in a centrifuge by the stabilizing influence of the Coriolis force

    NASA Astrophysics Data System (ADS)

    Müller, G.; Neumann, G.; Weber, W.

    1992-04-01

    Both experimental and numerical results on crystal growth and fluid flow studies carried out in a centrifuge are reported. It is shown that the formation of doping striations can be avoided in the vertical Bridgman and the horizontal zone melting growth of Te-doped InSb if the centrifugal acceleration is increased beyond a critical value depending on the thermal boundary conditions. Furthermore, the maximum rate for the growth of inclusion free GaSb crystals grown by the travelling heater method (THM) is increased by a factor of 10 if this method is carried out at an acceleration of 20 times earth gravity. Model experiments in the Bridgman configuration using a test cell with liquid Ga and a larger series of thermocouples are conducted by varying the thermal boundary conditions and the rotation rate of the centrifuge. A three-dimensional time dependent numerical simulation of the fluid flow under the experimental conditions was carried out using a finite difference numerical scheme. It follows clearly that the Coriolis force acting on the melt in the rotating centrifuge system significantly influences the buoyancy-driven convection with respect to the flow patterns as well as the stability. The Coriolis force causes two very different flow states (I and II), depending on whether the rotation sense of the flow is in the same or in the opposite direction to that of the centrifuge. Type I is very similar to that normally observed on earth. Type II is only observed on the centrifuge and has a very large stability range of steady convection which can be used to grow striation-free crystals. All results give excellent agreement between model experiments and numerical calculations, which finally leads to a fully satisfying explanation of the crystal growth results on our centrifuge.

  18. Artificial gravity studies and design considerations for Space Station centrifuges

    NASA Technical Reports Server (NTRS)

    Halstead, T. W.; Brown, A. H.; Fuller, C. A.; Oyama, J.

    1984-01-01

    The requirements to and capabilities of a Space Station biological facility centrifuge are discussed on the basis of an assessment of the objectives and subjects of future microgravity biological experiments. It is argued that the facility should be capable of both acute and extended chronic exposure of test subjects and biological materials to altered-g loading. In addition, the experimental approaches and equipment for microgravity studies on a Space Station are outlined. Finally, the engineering requirements of such a centrifuge are examined, with consideration of radial gravity gradients, size, and physical access to animals.

  19. Vacuum chamber-free centrifuge with magnetic bearings.

    PubMed

    Park, Cheol Hoon; Kim, Soohyun; Kim, Kyung-Soo

    2013-09-01

    Centrifuges are devices that separate particles of different densities and sizes through the application of a centrifugal force. If a centrifuge could be operated under atmospheric conditions, all vacuum-related components such as the vacuum chamber, vacuum pump, diffusion pump, and sealing could be removed from a conventional centrifuge system. The design and manufacturing procedure for centrifuges could then be greatly simplified to facilitate the production of lightweight centrifuge systems of smaller volume. Furthermore, the maintenance costs incurred owing to wear and tear due to conventional ball bearings would be eliminated. In this study, we describe a novel vacuum chamber-free centrifuge supported by magnetic bearings. We demonstrate the feasibility of the vacuum chamber-free centrifuge by presenting experimental results that verify its high-speed support capability and motoring power capacity.

  20. Stress analysis of bolted joints under centrifugal force

    NASA Astrophysics Data System (ADS)

    Imura, Makoto; Iizuka, Motonobu; Nakae, Shigeki; Mori, Takeshi; Koyama, Takayuki

    2014-06-01

    Our objective is to develop a long-life rotary machine for synchronous generators and motors. To do this, it is necessary to design a high-strength bolted joint, which is responsible for fixing a salient pole on a rotor shaft. While the rotary machine is in operation, not only centrifugal force but also moment are loaded on a bolted joint, because a point of load is eccentric to a centre of a bolt. We tried to apply the theory proposed in VDI2230-Blatt1 to evaluate the bolted joint under eccentric force, estimate limited centrifugal force, which is the cause of partial separation between the pole and the rotor shaft, and then evaluate additional tension of a bolt after the partial separation has occurred. We analyzed the bolted joint by FEM, and defined load introduction factor in that case. Additionally, we investigated the effect of the variation of bolt preload on the partial separation. We did a full scale experiment with a prototype rotor to reveal the variation of bolt preload against tightening torque. After that, we verified limited centrifugal force and the strength of the bolted joint by the VDI2230-Blatt1 theory and FEM considering the variation of bolt preload. Finally, we could design a high-strength bolted joint verified by the theoretical study and FEM analysis.

  1. The rotordynamic forces on a centrifugal pump impeller in the presence of cavitation

    NASA Technical Reports Server (NTRS)

    Franz, R.; Acosta, A. J.; Brennen, C. E.; Caughey, T. K.

    1990-01-01

    Fluid-induced rotordynamic forces on a centrifugal pump impeller whirling along a trajectory eccentric to its undeflected position in the presence of cavitation were measured using the experimental facility described by Jery (1987). The force measured is a combination of a steady radial force due to the volute asymmetries and an unsteady force due to the eccentric motion of the rotor. It was found that, compared to the noncavitation condition, a cavitation corresponding to a head loss of 3 percent had little effect upon the unsteady force. However, a lesser degree of cavitation at the design point, was found to increase the destabilizing force for a particular set of whirl ratios.

  2. Effects of anisotropic thermal conduction on wind properties in hot accretion flow

    NASA Astrophysics Data System (ADS)

    Bu, De-Fu; Wu, Mao-Chun; Yuan, Ye-Fei

    2016-06-01

    Previous works have clearly shown the existence of winds from black hole hot accretion flow and investigated their detailed properties. In extremely low accretion rate systems, the collisional mean-free path of electrons is large compared with the length-scale of the system, thus thermal conduction is dynamically important. When the magnetic field is present, the thermal conduction is anisotropic and energy transport is along magnetic field lines. In this paper, we study the effects of anisotropic thermal conduction on the wind production in hot accretion flows by performing two-dimensional magnetohydrodynamic simulations. We find that thermal conduction has only moderate effects on the mass flux of wind. But the energy flux of wind can be increased by a factor of ˜10 due to the increase of wind velocity when thermal conduction is included. The increase of wind velocity is because of the increase of driving forces (e.g. gas pressure gradient force and centrifugal force) when thermal conduction is included. This result demonstrates that thermal conduction plays an important role in determining the properties of wind.

  3. Salvaging urospermic ejaculates from brown bear (Ursus arctos).

    PubMed

    Gomes-Alves, S; Alvarez, M; Nicolas, M; Martínez-Rodríguez, C; Borragán, S; Chamorro, C A; Anel, L; de Paz, P

    2014-11-30

    The objective of this study was to reverse the osmotic stress of sperm in urine contaminated bear ejaculates that were obtained by electroejaculation using pre-freezing washing or density gradient centrifugation isolation. In Experiment 1, ejaculates were divided into six aliquots, five were diluted in each washing extender: 200, 300, 400, 500 and 700 mOsm/kg (prepared from a Tes-Tris-Fructose base, adding water or fructose as corresponds), at a 1:2 ratio (raw semen: washing solution, v/v); and the other aliquot was handled without washing (Control group). Samples were centrifuged at 600 × g for 6 min prior to freezing. In Experiment 2, ejaculates were divided into two aliquots: one was diluted 1:1 with TCG (Tris-Citric acid-Glucose) and centrifuged at 600 × g for 6 min (Centrifugation Control; C-Control); the other was treated with PureSperm density gradient column. After treatments, samples were cryopreserved. Sperm motility, viability (SYBR-14/propidium iodide (PI)) and acrosomal status (peanut agglutinin-fluorescein isothiocyanate (PNA-FITC)/PI) were analyzed before and after freezing. Ejaculates with an initial osmolality of less than 120 mOsm/kg treated with pre-freezing washing, and the Control sample had greater pre-freezing sperm motility than the raw ejaculate, but sperm viability was not different among these groups. The samples washed with 700 mOsm/kg solutions had the least pre-freezing viability. In the post-thawing evaluation, pre-freezing washing treatments did not provide any improvement in comparison with the Control sample, and treatment with 700 mOsm/kg extender had deleterious effects in all urospermic samples. PureSperm density gradient centrifugation applied to urospermic raw semen was suitable for improving sperm motility and viability of pre-freezing samples and the selected spermatozoa had greater freezing capacity. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Centripetal and centrifugal forces in the moral circle: Competing constraints on moral learning.

    PubMed

    Graham, Jesse; Waytz, Adam; Meindl, Peter; Iyer, Ravi; Young, Liane

    2017-10-01

    The idea of the moral circle pictures the self in the center, surrounded by concentric circles encompassing increasingly distant possible targets of moral concern, including family, local community, nation, all humans, all mammals, all living things including plants, and all things including inanimate objects. The authors develop the idea of two opposing forces in people's moral circles, with centripetal forces pulling inward, urging greater concern for close others than for distant others, and centrifugal forces pushing outward, resisting "drawing the line" anywhere as a form of prejudice and urging egalitarian concern for all regardless of social distance. Review of the developmental literature shows very early emergence of both moral forces, suggesting at least partly intuitive bases for each. Moral education approaches favoring one force over the other are compared, to show how these forces can provide constraints on moral learning. Finally, the centripetal/centrifugal forces view is applied to current moral debates about empathy and about politics. The authors argue that this view helps us see how intercultural and interpersonal disagreements about morality are based in intrapersonal conflicts shared by all people. Copyright © 2016. Published by Elsevier B.V.

  5. Modeling on Fluid Flow and Inclusion Motion in Centrifugal Continuous Casting Strands

    NASA Astrophysics Data System (ADS)

    Wang, Qiangqiang; Zhang, Lifeng; Sridhar, Seetharaman

    2016-08-01

    During the centrifugal continuous casting process, unreasonable casting parameters can cause violent level fluctuation, serious gas entrainment, and formation of frozen shell pieces at the meniscus. Thus, in the current study, a three-dimensional multiphase turbulent model was established to study the transport phenomena during centrifugal continuous casting process. The effects of nozzle position, casting and rotational speed on the flow pattern, centrifugal force acting on the molten steel, level fluctuation, gas entrainment, shear stress on mold wall, and motion of inclusions during centrifugal continuous casting process were investigated. Volume of Fluid model was used to simulate the molten steel-air two-phase. The level fluctuation and the gas entrainment during casting were calculated by user-developed subroutines. The trajectory of inclusions in the rotating system was calculated using the Lagrangian approach. The results show that during centrifugal continuous casting, a large amount of gas was entrained into the molten steel, and broken into bubbles of various sizes. The greater the distance to the mold wall, the smaller the centrifugal force. Rotation speed had the most important influence on the centrifugal force distribution at the side region. Angular moving angle of the nozzle with 8° and keeping the rotation speed with 60 revolutions per minute can somehow stabilize the level fluctuation. The increase of angular angle of nozzle from 8 to 18 deg and rotation speed from 40 to 80 revolutions per minute favored to decrease the total volume of entrained bubbles, while the increase of distance of nozzle moving left and casting speed had reverse effects. The trajectories of inclusions in the mold were irregular, and then rotated along the strand length. After penetrating a certain distance, the inclusions gradually moved to the center of billet and gathered there. More work, such as the heat transfer, the solidification, and the inclusions entrapment during centrifugal continuous casting, will be performed.

  6. Centrifugal Sieve for Gravity-Level-Independent Size Segregation of Granular Materials

    NASA Technical Reports Server (NTRS)

    Walton, Otis R.; Dreyer, Christopher; Riedel, Edward

    2013-01-01

    Conventional size segregation or screening in batch mode, using stacked vibrated screens, is often a time-consuming process. Utilization of centrifugal force instead of gravity as the primary body force can significantly shorten the time to segregate feedstock into a set of different-sized fractions. Likewise, under reduced gravity or microgravity, a centrifugal sieve system would function as well as it does terrestrially. When vibratory and mechanical blade sieving screens designed for terrestrial conditions were tested under lunar gravity conditions, they did not function well. The centrifugal sieving design of this technology overcomes the issues that prevented sieves designed for terrestrial conditions from functioning under reduced gravity. These sieves feature a rotating outer (cylindrical or conical) screen wall, rotating fast enough for the centrifugal forces near the wall to hold granular material against the rotating screen. Conventional centrifugal sieves have a stationary screen and rapidly rotating blades that shear the granular solid near the stationary screen, and effect the sieving process assisted by the airflow inside the unit. The centrifugal sieves of this new design may (or may not) have an inner blade or blades, moving relative to the rotating wall screen. Some continuous flow embodiments would have no inner auger or blades, but achieve axial motion through vibration. In all cases, the shearing action is gentler than conventional centrifugal sieves, which have very high velocity differences between the stationary outer screen and the rapidly rotating blades. The new design does not depend on airflow in the sieving unit, so it will function just as well in vacuum as in air. One advantage of the innovation for batch sieving is that a batch-mode centrifugal sieve may accomplish the same sieving operation in much less time than a conventional stacked set of vibrated screens (which utilize gravity as the primary driving force for size separation). In continuous mode, the centrifugal sieves can provide steady streams of fine and coarse material separated from a mixed feedstock flow stream. The centrifugal sieves can be scaled to any desired size and/or mass flow rate. Thus, they could be made in sizes suitable for small robotic exploratory missions, or for semi-permanent processing of regolith for extraction of volatiles of minerals. An advantage of the continuous-mode system is that it can be made with absolutely no gravity flow components for feeding material into, or for extracting the separated size streams from, the centrifugal sieve. Thus, the system is capable of functioning in a true microgravity environment. Another advantage of the continuous-mode system is that some embodiments of the innovation have no internal blades or vanes, and thus, can be designed to handle a very wide range of feedstock sizes, including occasional very large oversized pieces, without jamming or seizing up.

  7. High quality gold nanorods and nanospheres for surface-enhanced Raman scattering detection of 2,4-dichlorophenoxyacetic acid

    NASA Astrophysics Data System (ADS)

    Jia, Jin-Liang; Xu, Han-Hong; Zhang, Gui-Rong; Hu, Zhun; Xu, Bo-Qing

    2012-12-01

    Nearly monodisperse Au nanorods (NRs) with different aspect ratios were separated from home-synthesized polydisperse samples using a gradient centrifugation method. The morphology, size and its distribution, and photo-absorption property were analyzed by transmission electron microscopy, atomic force microscopy and UV-visible spectroscopy. Subsequently, using colloidal Au NRs (36.2 nm ×10.7 nm) with 97.4% yield after centrifugation and Au nanospheres (NSs) (22.9 ± 1.0 nm in diameter) with 97.6% yield as Au substrates, surface-enhanced Raman scattering (SERS) spectra of 2,4-dichlorophenoxyacetic acid (2,4-D) were recorded using laser excitation at 632.8 nm. Results show that surface enhancement factors (EF) for Au NRs and NSs are 6.2 × 105 and 5.7 × 104 using 1.0 × 10-6 M 2,4-D, respectively, illustrating that EF value is a factor of ˜10 greater for Au NRs substrates than for Au NSs substrates. As a result, large EF are a mainly result of chemical enhancement mechanisms. Thus, it is expected that Au NPs can find a comprehensive SERS application in the trace detection of pesticide residues.

  8. High quality gold nanorods and nanospheres for surface-enhanced Raman scattering detection of 2,4-dichlorophenoxyacetic acid.

    PubMed

    Jia, Jin-Liang; Xu, Han-Hong; Zhang, Gui-Rong; Hu, Zhun; Xu, Bo-Qing

    2012-12-14

    Nearly monodisperse Au nanorods (NRs) with different aspect ratios were separated from home-synthesized polydisperse samples using a gradient centrifugation method. The morphology, size and its distribution, and photo-absorption property were analyzed by transmission electron microscopy, atomic force microscopy and UV-visible spectroscopy. Subsequently, using colloidal Au NRs (36.2 nm ×10.7 nm) with 97.4% yield after centrifugation and Au nanospheres (NSs) (22.9 ± 1.0 nm in diameter) with 97.6% yield as Au substrates, surface-enhanced Raman scattering (SERS) spectra of 2,4-dichlorophenoxyacetic acid (2,4-D) were recorded using laser excitation at 632.8 nm. Results show that surface enhancement factors (EF) for Au NRs and NSs are 6.2 × 10(5) and 5.7 × 10(4) using 1.0 × 10(-6) M 2,4-D, respectively, illustrating that EF value is a factor of ~10 greater for Au NRs substrates than for Au NSs substrates. As a result, large EF are a mainly result of chemical enhancement mechanisms. Thus, it is expected that Au NPs can find a comprehensive SERS application in the trace detection of pesticide residues.

  9. Schizosaccharomyces pombe Polysome Profile Analysis and RNA Purification.

    PubMed

    Wolf, Dieter A; Bähler, Jürg; Wise, Jo Ann

    2017-04-03

    Polysome profile analysis is widely used by investigators studying the mechanism and regulation of translation. The method described here uses high-velocity centrifugation of whole cell extracts on linear sucrose gradients to separate 40S and 60S ribosomal subunits from 80S monosomes and polysomes. Cycloheximide is included in the lysis buffer to "freeze" polysomes by blocking translation. After centrifugation, the gradient is fractionated and RNA (and/or protein) is prepared from each fraction for subsequent analysis of individual species using northern or western blots. The entire RNA population in each fraction can be analyzed by hybridization to microarrays or by high-throughput RNA sequencing, and the proteins present can be identified by mass spectrometry analysis. © 2017 Cold Spring Harbor Laboratory Press.

  10. Hydrodynamic impeller stiffness, damping, and inertia in the rotordynamics of centrifugal flow pumps

    NASA Technical Reports Server (NTRS)

    Jery, S.; Acosta, A. J.; Brennen, C. E.; Caughey, T. K.

    1984-01-01

    The lateral hydrodynamic forces experienced by a centrifugal pump impeller performing circular whirl motions within several volute geometries were measured. The lateral forces were decomposed into: (1) time averaged lateral forces and (2) hydrodynamic force matrices representing the variation of the lateral forces with position of the impeller center. It is found that these force matrices essentially consist of equal diagonal terms and skew symmetric off diagonal terms. One consequence of this is that during its whirl motion the impeller experiences forces acting normal and tangential to the locus of whirl. Data on these normal and tangential forces are presented; it is shown that there exists a region of positive reduced whirl frequencies, within which the hydrodynamic forces can be destablizing with respect to whirl.

  11. Gravitropism interferes with hydrotropism via counteracting auxin dynamics in cucumber roots: clinorotation and spaceflight experiments.

    PubMed

    Morohashi, Keita; Okamoto, Miki; Yamazaki, Chiaki; Fujii, Nobuharu; Miyazawa, Yutaka; Kamada, Motoshi; Kasahara, Haruo; Osada, Ikuko; Shimazu, Toru; Fusejima, Yasuo; Higashibata, Akira; Yamazaki, Takashi; Ishioka, Noriaki; Kobayashi, Akie; Takahashi, Hideyuki

    2017-09-01

    Roots of land plants show gravitropism and hydrotropism in response to gravity and moisture gradients, respectively, for controlling their growth orientation. Gravitropism interferes with hydrotropism, although the mechanistic aspects are poorly understood. Here, we differentiated hydrotropism from gravitropism in cucumber roots by conducting clinorotation and spaceflight experiments. We also compared mechanisms regulating hydrotropism and auxin-regulated gravitropism. Clinorotated or microgravity (μG)-grown cucumber seedling roots hydrotropically bent toward wet substrate in the presence of moisture gradients, but they grew straight in the direction of normal gravitational force at the Earth's surface (1G) on the ground or centrifuge-generated 1G in space. The roots appeared to become hydrotropically more sensitive to moisture gradients under μG conditions in space. Auxin transport inhibitors significantly reduced the hydrotropic response of clinorotated seedling roots. The auxin efflux protein CsPIN5 was differentially expressed in roots of both clinorotated and μG-grown seedlings; with higher expression in the high-humidity (concave) side than the low-humidity (convex) side of hydrotropically responding roots. Our results suggest that roots become hydrotropically sensitive in μG, and CsPIN5-mediated auxin transport has an important role in inducing root hydrotropism. Thus, hydrotropic and gravitropic responses in cucumber roots may compete via differential auxin dynamics established in response to moisture gradients and gravity. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  12. Testing of a Loop Heat Pipe Subjective to Variable Accelerations. Part 1; Start-up

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Rogers, Paul; Hoff, Craig

    2000-01-01

    The effect of accelerating forces on the performance of loop heat pipes (LHP) is of interest and importance to terrestrial and space applications. They are being considered for cooling of military combat vehicles and for spinning spacecraft. In order to investigate the effect of an accelerating force on LHP operation, a miniature LHP was installed on a spin table. Variable accelerating forces were imposed on the LHP by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting accelerations ranged from 1.17 g's to 4.7 g's. This paper presents the first part of the experimental study, i.e. the effects of a centrifugal force on the LHP start-up. Tests were conducted by varying the heat load to the evaporator, sink temperature, magnitude and frequency of centrifugal force, and LHP orientation relative to the direction of the accelerating force. The accelerating force seems to have little effect on the loop start-up in terms of temperature overshoot and superheat at boiling incipience. Changes in these parameters seem to be stochastic with or without centrifugal accelerating forces. The LHP started successfully in all tests.

  13. Centrifugal adsorption system

    NASA Technical Reports Server (NTRS)

    Gonda, Steve R. (Inventor); Tsao, Yow-Min D. (Inventor); Lee, Wenshan (Inventor)

    2006-01-01

    A gas-liquid separator uses a helical passageway to impart a spiral motion to a fluid passing therethrough. The centrifugal force generated by the spiraling motion urges the liquid component of the fluid radially outward which forces the gas component radially inward. The gas component is then separated through a gas-permeable, liquid-impervious membrane and discharged through a central passageway. A filter material captures target substances contained in the fluid.

  14. Effects of centrifugation stress on pituitary-gonadal function in male rats

    NASA Technical Reports Server (NTRS)

    Gray, G. D.; Smith, E. R.; Damassa, D. A.; Davidson, J. M.

    1980-01-01

    The effects of centrifugation for various lengths of time on circulating levels of luteinizing hormone (LH) and testosterone in male rats were investigated. In a chronic 52-day experiment, centrifugation at 4.1 G significantly reduced LH and testosterone levels for the entire period. Centrifugation at 2.3 G had less effect inasmuch as LH levels were not significantly decreased and testosterone levels were significantly reduced only during the first few days of centrifugation. In more acute experiments, centrifugation at 4.1 G for 4 h resulted in reduced testosterone levels, whereas centrifugation for 15 min did not significantly alter the hormone levels. These results indicate that centrifugation can decrease circulating LH and testosterone levels if the gravitational force is of sufficient magnitude and is maintained for a period of hours. Chronic centrifugation may also inhibit the acute excitatory response of LH to handling and ether stress.

  15. Solid-phase based on-chip DNA purification through a valve-free stepwise injection of multiple reagents employing centrifugal force combined with a hydrophobic capillary barrier pressure.

    PubMed

    Zhang, Hainan; Tran, Hong Hanh; Chung, Bong Hyun; Lee, Nae Yoon

    2013-03-21

    In this paper, we demonstrate a simple technique for sequentially introducing multiple sample liquids into microchannels driven by centrifugal force combined with a hydrophobic barrier pressure and apply the technique for performing solid-phase based on-chip DNA purification. Three microchannels with varying widths, all equipped with independent sample reservoirs at the inlets, were fabricated on a hydrophobic elastomer, poly(dimethylsiloxane) (PDMS). First, glass beads were packed inside the reaction chamber, and a whole cell containing the DNA extract was introduced into the widest channel by applying centrifugal force for physical adsorption of the DNA onto the glass beads. Next, washing and elution solutions were sequentially introduced into the intermediate and narrowest microchannels, respectively, by gradually increasing the amount of centrifugal force. Through a precise manipulation of the centrifugal force, the DNA adsorbed onto the glass beads was successfully washed and eluted in a continuous manner without the need to introduce each solution manually. A stepwise injection of liquids was successfully demonstrated using multiple ink solutions, the results of which corresponded well with the theoretical analyses. As a practical application, the D1S80 locus of human genomic DNA, which is widely used for forensic purposes, was successfully purified using the microdevice introduced in this study, as demonstrated through successful target amplification. This will pave the way for the construction of a control-free valve system for realizing on-chip DNA purification, which is one of the most labor-intensive and hard-to-miniaturize components, on a greatly simplified and miniaturized platform employing hydrophobic PDMS.

  16. Surface Hardening of Composite Material by the Centrifugal-Casting Method

    NASA Astrophysics Data System (ADS)

    Eidelman, E. D.; Durnev, M. A.

    2018-04-01

    The effect of rotation flow emerging under centrifugal casting on the first-order phase transition, i.e., crystallization, has been studied using the example of producing a gradient composite material of AK12 aluminum alloy in a mixture with basalt fibers. It has been shown that a material with a hardened surface can be created. Distribution of admixtures in the main material when there is macroscopic motion has been found.

  17. Aerodynamically induced radial forces in a centrifugal gas compressor. Part 1: Experimental measurement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, J.J.; Flathers, M.B.

    1998-04-01

    Net radial loading arising from asymmetric pressure fields in the volutes of centrifugal pumps during off-design operation is well known and has been studied extensively. In order to achieve a marked improvement in overall efficiency in centrifugal gas compressors, vaneless volute diffusers are matched to specific impellers to yield improved performance over a wide application envelope. As observed in centrifugal pumps, nonuniform pressure distributions that develop during operation above and below the design flow create static radial loads on the rotor. In order to characterize these radial forces, a novel experimental measurement and post-processing technique is employed that yields bothmore » the magnitude and direction of the load by measuring the shaft centerline locus in the tilt-pad bearings. The method is applicable to any turbomachinery operating on fluid film radial bearings equipped with proximity probes. The forces are found to be a maximum near surge and increase with higher pressures and speeds. The results are nondimensionalized, allowing the radial loading for different operating conditions to be predicted.« less

  18. Centrifugally decoupling touchdown bearings

    DOEpatents

    Post, Richard F

    2014-06-24

    Centrifugally decoupling mechanical bearing systems provide thin tensioned metallic ribbons contained in a support structure. This assembly rotates around a stationary shaft being centered at low speeds by the action of the metal ribbons. Tension springs are connected on one end to the ribbons and on the other end to the support structure. The ribbons pass through slots in the inner ring of the support structure. The spring preloading thus insures contact (or near-contact) between the ribbons and the shaft at rotation speeds below the transition speed. Above this speed, however, the centrifugal force on the ribbons produces a tensile force on them that exceeds the spring tensile force so that the ribbons curve outward, effectively decoupling them from mechanical contact with the shaft. They still remain, however, in position to act as a touchdown bearing in case of abnormally high transverse accelerations.

  19. Capitalizing Resolving Power of Density Gradient Ultracentrifugation by Freezing and Precisely Slicing Centrifuged Solution: Enabling Identification of Complex Proteins from Mitochondria by Matrix Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    PubMed Central

    Yu, Haiqing; Lu, Joann J.; Rao, Wei

    2016-01-01

    Density gradient centrifugation is widely utilized for various high purity sample preparations, and density gradient ultracentrifugation (DGU) is often used for more resolution-demanding purification of organelles and protein complexes. Accurately locating different isopycnic layers and precisely extracting solutions from these layers play a critical role in achieving high-resolution DGU separations. In this technique note, we develop a DGU procedure by freezing the solution rapidly (but gently) after centrifugation to fix the resolved layers and by slicing the frozen solution to fractionate the sample. Because the thickness of each slice can be controlled to be as thin as 10 micrometers, we retain virtually all the resolution produced by DGU. To demonstrate the effectiveness of this method, we fractionate complex V from HeLa mitochondria using a conventional technique and this freezing-slicing (F-S) method. The comparison indicates that our F-S method can reduce complex V layer thicknesses by ~40%. After fractionation, we analyze complex V proteins directly on a matrix assisted laser desorption/ionization, time-of-flight mass spectrometer. Twelve out of fifteen subunits of complex V are positively identified. Our method provides a practical protocol to identify proteins from complexes, which is useful to investigate biomolecular complexes and pathways in various conditions and cell types. PMID:27668122

  20. CENTRIFUGE

    DOEpatents

    Rushing, F.C.

    1960-09-01

    A vibration damping mechanism for damping vibration forces occurring during the operation of a centrifuge is described. The vibration damping mechanism comprises a plurality of nested spaced cylindrical elements surrounding the rotating shaft of the centrifuge. Some of the elements are held substantially stationary while the others are held with respect to a pair of hearings spaced along the rotating shaft. A fluid is retained about the cylindrical elements.

  1. Isolation of symbiotic dinoflagellates by centrifugal elutriation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bird, A.E.; Quinn, R.J.

    1986-01-01

    Centrifugal elutriation, a method combining centripetal liquid flow with centrifugal force, has been used to isolate symbiotic dinoflagellates from a cnidarian host. The elutriated cells were shown to be viable by photosynthetic incorporation of /sup 14/CO/sub 2/ and low release of photosynthetic products into the incubation medium. The level of contamination by clinging debris was low and by host solids was negligible.

  2. Coil planet centrifugation as a means for small particle separation

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1983-01-01

    The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.

  3. Estimation of the radial force using a disturbance force observer for a magnetically levitated centrifugal blood pump.

    PubMed

    Pai, C N; Shinshi, T; Shimokohbe, A

    2010-01-01

    Evaluation of the hydraulic forces in a magnetically levitated (maglev) centrifugal blood pump is important from the point of view of the magnetic bearing design. Direct measurement is difficult due to the absence of a rotor shaft, and computational fluid dynamic analysis demands considerable computational resource and time. To solve this problem, disturbance force observers were developed, using the radial controlled magnetic bearing of a centrifugal blood pump, to estimate the radial forces on the maglev impeller. In order to design the disturbance observer, the radial dynamic characteristics of a maglev impeller were evaluated under different working conditions. It was observed that the working fluid affects the additional mass and damping, while the rotational speed affects the damping and stiffness of the maglev system. Based on these results, disturbance force observers were designed and implemented. The designed disturbance force observers present a bandwidth of 45 Hz. In non-pulsatile conditions, the magnitude of the estimated radial thrust increases in proportion to the flowrate, and the rotational speed has little effect on the force direction. At 5 l/min against 100 mmHg, the estimated radial thrust is 0.95 N. In pulsatile conditions, this method was capable of estimating the pulsatile radial thrust with good response.

  4. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments.

    PubMed

    Morita, Hironobu; Obata, Koji; Abe, Chikara; Shiba, Dai; Shirakawa, Masaki; Kudo, Takashi; Takahashi, Satoru

    2015-01-01

    To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments.

  5. Feasibility of a Short-Arm Centrifuge for Mouse Hypergravity Experiments

    PubMed Central

    Morita, Hironobu; Obata, Koji; Abe, Chikara; Shiba, Dai; Shirakawa, Masaki; Kudo, Takashi; Takahashi, Satoru

    2015-01-01

    To elucidate the pure impact of microgravity on small mammals despite uncontrolled factors that exist in the International Space Station, it is necessary to construct a 1 g environment in space. The Japan Aerospace Exploration Agency has developed a novel mouse habitat cage unit that can be installed in the Cell Biology Experiment Facility in the Kibo module of the International Space Station. The Cell Biology Experiment Facility has a short-arm centrifuge to produce artificial 1 g gravity in space for mouse experiments. However, the gravitational gradient formed inside the rearing cage is larger when the radius of gyration is shorter; this may have some impact on mice. Accordingly, biological responses to hypergravity induced by a short-arm centrifuge were examined and compared with those induced by a long-arm centrifuge. Hypergravity induced a significant Fos expression in the central nervous system, a suppression of body mass growth, an acute and transient reduction in food intake, and impaired vestibulomotor coordination. There was no difference in these responses between mice raised in a short-arm centrifuge and those in a long-arm centrifuge. These results demonstrate the feasibility of using a short-arm centrifuge for mouse experiments. PMID:26221724

  6. Supersonic cavity flows over concave and convex walls

    NASA Astrophysics Data System (ADS)

    Ye, A. Ran; Das, Rajarshi; Setoguchi, Toshiaki; Kim, Heuy Dong

    2016-04-01

    Supersonic cavity flows are characterized by compression and expansion waves, shear layer, and oscillations inside the cavity. For decades, investigations into cavity flows have been conducted, mostly with flows at zero pressure gradient entering the cavity in straight walls. Since cavity flows on curved walls exert centrifugal force, the features of these flows are likely to differ from those of straight wall flows. The aim of the present work is to study the flow physics of a cavity that is cut out on a curved wall. Steady and unsteady numerical simulations were carried out for supersonic flow through curved channels over the cavity with L/H = 1. A straight channel flow was also analyzed which serves as the base model. The velocity gradient along the width of the channel was observed to increase with increasing the channel curvature for both concave and convex channels. The pressure on the cavity floor increases with the increase in channel curvature for concave channels and decreases for convex channels. Moreover, unsteady flow characteristics are more dependent on channel curvature under supersonic free stream conditions.

  7. Semicircular canal influence on the visually perceived eye level during gondola centrifugation.

    PubMed

    Tribukait, Arne; Eiken, Ola

    2006-05-01

    When exposed to an increased gravitoinertial force, a subject, sitting upright, experiences an illusion of being tilted backwards. This so-called "G-excess illusion" is generally ascribed to the otolith organs. The present study aimed at elucidating how stimulation of the semicircular canals may influence the development of the G-excess illusion. The visually perceived eye level (VPEL) was measured by means of a visual indicator in a large swing-out gondola centrifuge. The roll position of the gondola was controlled so that the subject was always upright with respect to the resultant vector of the Earth gravity force and the centrifugal force. Subjects (n = 8) underwent four centrifuge runs (2 G, 5 min), sitting in different positions, i.e., heading forwards, backwards, centripetally, and centrifugally. At the 2-G plateau there was a depression of the VPEL which was initially small but increased with a time constant of 90 +/- 30 s toward an asymptote of -22.0 +/- 6.9 degrees (mean and 1 SD for all positions). The initial depression was significantly smaller for the centripetal (+2.0 +/- 14.6 degrees) than for the centrifugal position (-14.5 +/- 10.4 degrees). However, there was no difference between the forward (-5.6 +/- 4.8 degrees) and backward (-4.0 +/- 4.5 degrees) positions. Initially after deceleration of the centrifuge to 1 G there was still a significant depression of the VPEL (-13.5 +/- 7.9 degrees), decreasing with a time constant of 100 +/- 46 s. The considerable delay in the otolith-mediated changes in the VPEL is interpreted as due to the absence of adequate canal information for a change in head position. The difference in VPEL between the centripetal and centrifugal positions suggests an influence of canal change-in-position information. However, pitch-plane angular velocity, being of considerable magnitude but of opposite sign for the forward and backward positions, did not influence the VPEL.

  8. Optimisation of a double-centrifugation method for preparation of canine platelet-rich plasma.

    PubMed

    Shin, Hyeok-Soo; Woo, Heung-Myong; Kang, Byung-Jae

    2017-06-26

    Platelet-rich plasma (PRP) has been expected for regenerative medicine because of its growth factors. However, there is considerable variability in the recovery and yield of platelets and the concentration of growth factors in PRP preparations. The aim of this study was to identify optimal relative centrifugal force and spin time for the preparation of PRP from canine blood using a double-centrifugation tube method. Whole blood samples were collected in citrate blood collection tubes from 12 healthy beagles. For the first centrifugation step, 10 different run conditions were compared to determine which condition produced optimal recovery of platelets. Once the optimal condition was identified, platelet-containing plasma prepared using that condition was subjected to a second centrifugation to pellet platelets. For the second centrifugation, 12 different run conditions were compared to identify the centrifugal force and spin time to produce maximal pellet recovery and concentration increase. Growth factor levels were estimated by using ELISA to measure platelet-derived growth factor-BB (PDGF-BB) concentrations in optimised CaCl 2 -activated platelet fractions. The highest platelet recovery rate and yield were obtained by first centrifuging whole blood at 1000 g for 5 min and then centrifuging the recovered platelet-enriched plasma at 1500 g for 15 min. This protocol recovered 80% of platelets from whole blood and increased platelet concentration six-fold and produced the highest concentration of PDGF-BB in activated fractions. We have described an optimised double-centrifugation tube method for the preparation of PRP from canine blood. This optimised method does not require particularly expensive equipment or high technical ability and can readily be carried out in a veterinary clinical setting.

  9. Density gradient centrifugation prior to cryopreservation and hypotaurine supplementation improve post-thaw quality of sperm from infertile men with oligoasthenoteratozoospermia.

    PubMed

    Brugnon, F; Ouchchane, L; Pons-Rejraji, H; Artonne, C; Farigoule, M; Janny, L

    2013-08-01

    Can selection of spermatozoa by density gradient centrifugation prior to cryopreservation and/or hypotaurine supplementation improve the post-thaw quality of sperm from infertile men with oligoasthenoteratozoospermia? Sperm selection by density gradient centrifugation before freezing and supplementation of the media by hypotaurine is beneficial for the cryopreservation of semen samples of patients with oligoasthenoteratozoospermia. Sperm from men with oligoasthenoteratozoospermia are more susceptible than normal to cryoinjury. Density gradient centrifugation before sperm freezing may allow the selection of a subpopulation of spermatozoa more resistant to cryopreservation. Hypotaurine is an antioxidant with a protective effect on sperm functions. The experiment was carried out according to a factorial design involving two binary factors resulting in four treatment combinations which were randomly allocated in oligoasthenoteratozoospermia sperm samples from 64 patients recruited between January 2009 and June 2010. Semen was provided by 64 men undergoing evaluation for infertility at the Centre for Reproductive Medicine of the University Hospital in Clermont-Ferrand, France, between January 2009 and June 2010. Four treatment combinations were tested: sperm freezing before selection without (F-S/H-; n = 16) and with hypotaurine supplementation (F-S/H+; n = 16); sperm selection before freezing without (S-F/H-; n = 16) and with hypotaurine supplementation (S-F/H+; n = 16). Measurements of sperm recovery rates and markers of apoptosis (externalization of phosphatidylserine (PS), mitochondrial membrane potential and DNA fragmentation) were compared in recovered spermatozoa after each procedure. Higher recovery rates of progressive and total motile spermatozoa were observed when sperm selection was performed before freezing (P < 0.05). The protective effect of hypotaurine was only observed on the percentage of live spermatozoa with PS externalization among total live spermatozoa (AN+ PI-/((AN+ PI-) + (AN- PI-)) when the sperm selection by density gradient centrifugation was performed before freezing (S-F/H+ versus S-F/H-: 6.8 ± 1.09 versus 11.8 ± 2.03%, P = 0.04). The percentage of mitochondrial membrane potential (DiOC6(3) (high)) spermatozoa was higher (P = 0.001) when sperm selection was done before freezing compared with procedures in which sperm selection was done after sperm freezing with (S-F/H+ versus F-S/H+: 58.1 ± 3.50 versus 46.7 ± 5.48%) or without (S-F/H- versus F-S/H-: 57.0 ± 5.18 versus 35.4 ± 4.99%) hypotaurine supplementation. The percentages of TUNEL+ spermatozoa were significantly lower (P = 0.001) when sperm selection was done before sperm freezing compared with procedures in which sperm selection was done after sperm freezing with (S-F/H+ versus F-S/H+: 38.6 ± 9.59 versus 55.7 ± 5.88%) or without hypotaurine supplementation (S-F/H- versus F-S/H-: 37.2 ± 7.91 versus 71.0 ± 5.66%). The ICSI outcomes were not assessed and the fertility of the spermatozoa remains unknown. Sperm selection by density gradient centrifugation before freezing and hypotaurine supplementation could improve the cryopreservation of sperm from oligoasthenoteratozoospermic men and make a larger number of functional spermatozoa available for ICSI. This work was supported by a hospital grant (Projet Hospitalier Recherche Clinique, CHU Clermont Ferrand, France). None of the authors has any conflict of interest to declare.

  10. On the competition of forces in the Kerr field

    NASA Astrophysics Data System (ADS)

    Semerak, O.

    1994-11-01

    'Rotosphere', where the component of 4-acceleration, radial relative to the symmetry axis, of the stationary observer depends on his angular velocity in a way going against our intuition, is demarcated in the Kerr spacetime. Stationary observers with extremal value of this acceleration ('extremelly accelerated observers') are introduced and their privileged relation to circular geodesics in the equatorial plane is found. Possible translation of the results into 'force' language is based on the definition of the 'centrifugal force' with respect to the zero-angular-momentum observers. It yields, in particular, a simple interpretation of the behavior of acceleration of the stationary observer in terms of gravitational, Coriolis and centrifugal forces.

  11. Problem-based test: replication of mitochondrial DNA during the cell cycle.

    PubMed

    Sétáló, György

    2013-01-01

    Terms to be familiar with before you start to solve the test: cell cycle, generation time, S-phase, cell culture synchronization, isotopic pulse-chase labeling, density labeling, equilibrium density-gradient centrifugation, buoyant density, rate-zonal centrifugation, nucleoside, nucleotide, kinase enzymes, polymerization of nucleic acids, re-replication block, cell fractionation, Svedberg (sedimentation constant = [ S]), nuclear DNA, mitochondrial DNA, heavy and light mitochondrial DNA chains, heteroplasmy, mitochondrial diseases Copyright © 2013 Wiley Periodicals, Inc.

  12. Roles of dynamical symmetry breaking in driving oblate-prolate transitions of atomic clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oka, Yurie, E-mail: ok-yu@fuji.waseda.jp; Yanao, Tomohiro, E-mail: yanao@waseda.jp; Koon, Wang Sang, E-mail: koon@cds.caltech.edu

    2015-04-07

    This paper explores the driving mechanisms for structural transitions of atomic clusters between oblate and prolate isomers. We employ the hyperspherical coordinates to investigate structural dynamics of a seven-atom cluster at a coarse-grained level in terms of the dynamics of three gyration radii and three principal axes, which characterize overall mass distributions of the cluster. Dynamics of gyration radii is governed by two kinds of forces. One is the potential force originating from the interactions between atoms. The other is the dynamical forces called the internal centrifugal forces, which originate from twisting and shearing motions of the system. The internalmore » centrifugal force arising from twisting motions has an effect of breaking the symmetry between two gyration radii. As a result, in an oblate isomer, activation of the internal centrifugal force that has the effect of breaking the symmetry between the two largest gyration radii is crucial in triggering structural transitions into prolate isomers. In a prolate isomer, on the other hand, activation of the internal centrifugal force that has the effect of breaking the symmetry between the two smallest gyration radii is crucial in triggering structural transitions into oblate isomers. Activation of a twisting motion that switches the movement patterns of three principal axes is also important for the onset of structural transitions between oblate and prolate isomers. Based on these trigger mechanisms, we finally show that selective activations of specific gyration radii and twisting motions, depending on the isomer of the cluster, can effectively induce structural transitions of the cluster. The results presented here could provide further insights into the control of molecular reactions.« less

  13. Roles of dynamical symmetry breaking in driving oblate-prolate transitions of atomic clusters

    NASA Astrophysics Data System (ADS)

    Oka, Yurie; Yanao, Tomohiro; Koon, Wang Sang

    2015-04-01

    This paper explores the driving mechanisms for structural transitions of atomic clusters between oblate and prolate isomers. We employ the hyperspherical coordinates to investigate structural dynamics of a seven-atom cluster at a coarse-grained level in terms of the dynamics of three gyration radii and three principal axes, which characterize overall mass distributions of the cluster. Dynamics of gyration radii is governed by two kinds of forces. One is the potential force originating from the interactions between atoms. The other is the dynamical forces called the internal centrifugal forces, which originate from twisting and shearing motions of the system. The internal centrifugal force arising from twisting motions has an effect of breaking the symmetry between two gyration radii. As a result, in an oblate isomer, activation of the internal centrifugal force that has the effect of breaking the symmetry between the two largest gyration radii is crucial in triggering structural transitions into prolate isomers. In a prolate isomer, on the other hand, activation of the internal centrifugal force that has the effect of breaking the symmetry between the two smallest gyration radii is crucial in triggering structural transitions into oblate isomers. Activation of a twisting motion that switches the movement patterns of three principal axes is also important for the onset of structural transitions between oblate and prolate isomers. Based on these trigger mechanisms, we finally show that selective activations of specific gyration radii and twisting motions, depending on the isomer of the cluster, can effectively induce structural transitions of the cluster. The results presented here could provide further insights into the control of molecular reactions.

  14. Separation system

    DOEpatents

    Rubin, Leslie S.

    1986-01-01

    A separation system for dewatering radioactive waste materials includes a disposal container, drive structure for receiving the container, and means for releasably attaching the container to the drive structure. Separation structure disposed in the container adjacent the inner surface of the side wall structure retains solids while allowing passage of liquids. Inlet port structure in the container top wall is normally closed by first valve structure that is centrifugally actuated to open the inlet port and discharge port structure at the container periphery receives liquid that passes through the separation structure and is normally closed by second valve structure that is centrifugally actuated to open the discharge ports. The container also includes coupling structure for releasable engagement with the centrifugal drive structure. Centrifugal force produced when the container is driven in rotation by the drive structure opens the valve structures, and radioactive waste material introduced into the container through the open inlet port is dewatered, and the waste is compacted. The ports are automatically closed by the valves when the container drum is not subjected to centrifugal force such that containment effectiveness is enhanced and exposure of personnel to radioactive materials is minimized.

  15. Centrifugal Force Based Magnetic Micro-Pump Driven by Rotating Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Kim, S. H.; Hashi, S.; Ishiyama, K.

    2011-01-01

    This paper presents a centrifugal force based magnetic micro-pump for the pumping of blood. Most blood pumps are driven by an electrical motor with wired control. To develop a wireless and battery-free blood pump, the proposed pump is controlled by external rotating magnetic fields with a synchronized impeller. Synchronization occurs because the rotor is divided into multi-stage impeller parts and NdFeB permanent magnet. Finally, liquid is discharged by the centrifugal force of multi-stage impeller. The proposed pump length is 30 mm long and19 mm in diameter which much smaller than currently pumps; however, its pumping ability satisfies the requirement for a blood pump. The maximum pressure is 120 mmHg and the maximum flow rate is 5000ml/min at 100 Hz. The advantage of the proposed pump is that the general mechanical problems of a normal blood pump are eliminated by the proposed driving mechanism.

  16. Sticking properties of ice grains

    NASA Astrophysics Data System (ADS)

    Jongmanns, M.; Kumm, M.; Wurm, G.; Wolf, D. E.; Teiser, J.

    2017-06-01

    We study the size dependence of pull-off forces of water ice in laboratory experiments and numerical simulations. To determine the pull-off force in our laboratory experiments, we use a liquid nitrogen cooled centrifuge. Depending on its rotation frequency, spherical ice grains detach due to the centrifugal force which is related to the adhesive properties. Numerical simulations are conducted by means of molecular dynamics simulations of hexagonal ice using a standard coarse-grained water potential. The pull-off force of a single contact between two spherical ice grains is measured due to strain controlled simulations. Both, the experimental study and the simulations reveal a dependence between the pull-off force and the (reduced) particle radii, which differ significantly from the linear dependence of common contact theories.

  17. Secondary Circulation Asymmetry in a Meandering, Partially Stratified Estuary

    NASA Astrophysics Data System (ADS)

    Pein, J.; Valle-Levinson, A.; Stanev, E. V.

    2018-03-01

    Numerical model experiments are used to study the effects of multiple channel bends on estuarine dynamics and, in particular, on secondary flows. These effects are demonstrated by comparing experiments with two different idealized trumpet-shaped estuaries, one straight and another one with a ˜8 km meandering section in the middle of the estuary. Meanders complicate the flow field by introducing secondary processes. For instance, meanders increase turbulence and associated mixing locally within the water column, as well as outside the meandering portion. Furthermore, meanders transform up to 30% of the along-channel momentum into secondary circulation. Production of turbulence and secondary currents is different at flood and ebb tidal phases. At flood, meanders lead to unstable stratification and increased turbulence. At ebb, the flow develops a helical pattern and adjusts to the channel curvature with minimal decrease in density stability. The secondary circulation asymmetry is caused by an interplay between the across-channel baroclinic pressure gradient force and the centrifugal force. During ebb both forces enhance each other, whereas they oppose during flood. As a consequence of this interaction between baroclinic forcing and curving morphology, ebb flows and horizontal buoyancy fluxes increase relative to flood. The enhanced ebb dominance shifts a density front toward the mouth of the estuary, thus reducing salt intrusion.

  18. Protein removal from waste brines generated during ham salting through acidification and centrifugation.

    PubMed

    Gutiérrez-Martínez, Maria del Rosario; Muñoz-Guerrero, Hernán; Alcaína-Miranda, Maria Isabel; Barat, José Manuel

    2014-03-01

    The salting step in food processes implies the production of large quantities of waste brines, having high organic load, high conductivity, and other pollutants with high oxygen demand. Direct disposal of the residual brine implies salinization of soil and eutrophication of water. Since most of the organic load of the waste brines comes from proteins leaked from the salted product, precipitation of dissolved proteins by acidification and removal by centrifugation is an operation to be used in waste brine cleaning. The aim of this study is optimizing the conditions for carrying out the separation of proteins from waste brines generated in the pork ham salting operation, by studying the influence of pH, centrifugal force, and centrifugation time. Models for determining the removal of proteins depending on the pH, centrifugal force, and time were obtained. The results showed a high efficacy of the proposed treatment for removing proteins, suggesting that this method could be used for waste brine protein removal. The best pH value to be used in an industrial process seems to be 3, while the obtained results indicate that almost 90% of the proteins from the brine can be removed by acidification followed by centrifugation. A further protein removal from the brine should have to be achieved using filtrating techniques, which efficiency could be highly improved as a consequence of the previous treatment through acidification and centrifugation. Waste brines from meat salting have high organic load and electrical conductivity. Proteins can be removed from the waste brine by acidification and centrifugation. The total protein removal can be up to 90% of the initial content of the waste brine. Protein removal is highly dependent on pH, centrifugation rate, and time. © 2014 Institute of Food Technologists®

  19. Flow in a centrifugal fan impeller at off-design conditions

    NASA Astrophysics Data System (ADS)

    Wright, T.; Tzou, K. T. S.; Madhavan, S.

    1984-06-01

    A fully three-dimensional finite element analysis of inviscid, incompressible blade channel flow is the basis of the present study of both predicted and measured surface velocity and pressure distributions in the internal flow channels of a centrifugal fan impeller, for volume flow rates of 80-125 percent the design flow rate. The experimental results made extensive use of blade and sidewall surface pressure taps installed in a scale model of an airfoil-bladed centrifugal fan impeller. The results obtained illustrate the ability of both flow analyses to predict the dominant features of the impeller flow field, including peak blade surface velocities and adverse gradients at flows far from the design point. Insight is also gained into the limiting channel diffusion values for typical centrifugal cascade performance, together with the influence of viscous effects, as seen in deviations from ideal flow predictions.

  20. Confinement of plasma along shaped open magnetic fields from the centrifugal force of supersonic plasma rotation.

    PubMed

    Teodorescu, C; Young, W C; Swan, G W S; Ellis, R F; Hassam, A B; Romero-Talamas, C A

    2010-08-20

    Interferometric density measurements in plasmas rotating in shaped, open magnetic fields demonstrate strong confinement of plasma parallel to the magnetic field, with density drops of more than a factor of 10. Taken together with spectroscopic measurements of supersonic E × B rotation of sonic Mach 2, these measurements are in agreement with ideal MHD theory which predicts large parallel pressure drops balanced by centrifugal forces in supersonically rotating plasmas.

  1. Analysis of an arched outer-race ball bearing considering centrifugal forces.

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Anderson, W. J.

    1972-01-01

    Thrust-load analysis of a 150-mm angular contact ball bearing, taking into account centrifugal forces but omitting gyroscopics, elastohydrodynamics, and thermal effects. A Newton-Raphson method of iteration is used to evaluate the radial and axial projection of the distance between the ball center and the outer raceway groove curvature center. Fatigue life of the bearing is evaluated. Results for life, contact loads, and angles are given for a conventional bearing and two arched bearings.

  2. Isolation of Cytoplasmic Pituitary Granules with Gonadotropic Activity

    PubMed Central

    Hartley, Marshall W.; McShan, W. H.; Ris, Hans

    1960-01-01

    A fraction isolated from the anterior pituitary glands of rats castrate for 8 weeks contained essentially a single cytoplasmic constituent with which the major portion of the gonadotropic hormone activity was associated. The glands were homogenized in an 0.25 M sucrose + 7.3 per cent polyvinylpyrrolidone (PVP) solution and fractionated by differential centrifugation to give a heterogeneous small granule fraction which contained almost all the gonadotropic hormone activity. The active supernatant containing this small granule fraction was separated into layers by isopycnic gradient centrifugation on a continuous 6 to 45 per cent sucrose + 17.5 per cent "diodrast" + 5 x 10-4 M "versene" gradient at 100,000 g for 2 hours. Three layers were obtained and the pellet from the active bottom layer was sectioned, examined with the electron microscope, and found to contain 200 mµ granules, mitochondria, ergastoplasm, and other cellular debris. This layer was fractionated further by isopycnic and differential centrifugation to obtain a pellet which contained the major portion of the gonadotropic hormone activity. Because of the heterogeneity of this fraction, due to the contamination of the 200 mµ granules with mitochondria and other cellular debris, the active layer and the resuspended active pellet, obtained by centrifuging this layer first at 17,000 g then diluting the supernatant and centrifuging at 30,000 g for 1 hour, were filtered through Millipore HA paper with a pore size of 0.45 µ. The cytoplasmic material containing the gonadotropic hormone activity passed through the filter paper and this activity was recovered in the pellets obtained by centrifuging at 100,000 g for 1 hour. These active pellets consisted almost entirely of 200 mµ granules with a minimum amount of contamination, and they contained the major portion of the gonadotropic hormone activity with practically none remaining in the supernatant fraction. These results are discussed in view of their importance to the cytology of the pituitary gland. PMID:14400127

  3. The Meselson-Stahl Experiment

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2012-01-01

    Terms to be familiar with before you start to solve the test: DNA replication, nitrogen isotopes, density labeling, cesium chloride density gradient centrifugation, ultraviolet absorption, DNA denaturation, circular and linear DNA, superspiralization, superhelical DNA, and template.

  4. Gravitoinertial force background level affects adaptation to coriolis force perturbations of reaching movements

    NASA Technical Reports Server (NTRS)

    Lackner, J. R.; Dizio, P.

    1998-01-01

    We evaluated the combined effects on reaching movements of the transient, movement-dependent Coriolis forces and the static centrifugal forces generated in a rotating environment. Specifically, we assessed the effects of comparable Coriolis force perturbations in different static force backgrounds. Two groups of subjects made reaching movements toward a just-extinguished visual target before rotation began, during 10 rpm counterclockwise rotation, and after rotation ceased. One group was seated on the axis of rotation, the other 2.23 m away. The resultant of gravity and centrifugal force on the hand was 1.0 g for the on-center group during 10 rpm rotation, and 1.031 g for the off-center group because of the 0.25 g centrifugal force present. For both groups, rightward Coriolis forces, approximately 0.2 g peak, were generated during voluntary arm movements. The endpoints and paths of the initial per-rotation movements were deviated rightward for both groups by comparable amounts. Within 10 subsequent reaches, the on-center group regained baseline accuracy and straight-line paths; however, even after 40 movements the off-center group had not resumed baseline endpoint accuracy. Mirror-image aftereffects occurred when rotation stopped. These findings demonstrate that manual control is disrupted by transient Coriolis force perturbations and that adaptation can occur even in the absence of visual feedback. An increase, even a small one, in background force level above normal gravity does not affect the size of the reaching errors induced by Coriolis forces nor does it affect the rate of reacquiring straight reaching paths; however, it does hinder restoration of reaching accuracy.

  5. Waves in a gas centrifuge

    NASA Astrophysics Data System (ADS)

    Bogovalov, S. V.; Kislov, V. A.; Tronin, I. V.

    2016-09-01

    Impact of the pulsed braking force on the axial gas circulation and gas content in centrifuges for uranium isotope separation was investigated by the method of numerical simulation. Pulsed brake of the rotating gas by the momentum source results into generation of the waves which propagate along the rotor of the centrifuge. The waves almost doubles the axial circulation flux in the working camera in compare with the case of the steady state breaking force with the same average power in the model under the consideration. Flux through the hole in the bottom baffle on 15% exceeds the flux in the stationary case for the same pressure and temperature in the model. We argue that the waves reduce the pressure in the GC on the same 15%.

  6. Adiabatic Field-Free Alignment of Asymmetric Top Molecules with an Optical Centrifuge.

    PubMed

    Korobenko, A; Milner, V

    2016-05-06

    We use an optical centrifuge to align asymmetric top SO_{2} molecules by adiabatically spinning their most polarizable O-O axis. The effective centrifugal potential in the rotating frame confines the sulfur atoms to the plane of the laser-induced rotation, leading to the planar molecular alignment that persists after the molecules are released from the centrifuge. The periodic appearance of the full three-dimensional alignment, typically observed only with linear and symmetric top molecules, is also detected. Together with strong in-plane centrifugal forces, which bend the molecules by up to 10 deg, permanent field-free alignment offers new ways of controlling molecules with laser light.

  7. Subjective stress factors in centrifuge training for military aircrews.

    PubMed

    Lin, Pei-Chun; Wang, Jenhung; Li, Shih-Chin

    2012-07-01

    This study investigates stress-influence factors perceived by military aircrews undergoing centrifuge training, which lowers the incidence of G-induced loss of consciousness (G-LOC) for the crews of high-performance combat aircrafts. We used questionnaires to assess the subjective stress-influence factors of crews undergoing centrifuge training. Professionals in aviation physiology identified attributes measuring the perceived stress induced by centrifuge training, which were segmented into three constructs by factor analysis, theory lecture, centrifuge equipment, and physical fitness. Considerable interpenetration was discernible between these factors and military rank, age, length of service, flight hours accrued, and type of aircraft piloted. Identifying and quantifying the perceived stressors experienced in human-use centrifuge training enables aviators, astronauts, and air forces of the world to determine which constructs perceptibly increase or alleviate the perceived stress undergone by trainees when partaking in centrifuge training. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. Heat shock protein-containing exosomes in mid-trimester amniotic fluids.

    PubMed

    Asea, Alexzander; Jean-Pierre, Claudel; Kaur, Punit; Rao, Preethi; Linhares, Iara M; Skupski, Daniel; Witkin, Steven S

    2008-10-01

    Exosomes are multivesicular bodies formed by inverse membrane budding into the lumen of an endocytic compartment. Fusion with the plasma membrane leads to their release into the external milieu. The incorporation of heat shock proteins into exosomes has been associated with immune regulatory activity. We have examined whether heat shock protein-containing exosomes are present in mid-trimester amniotic fluid. Exosomes were isolated from mid-trimester amniotic fluids by sequential low-speed and high-speed centrifugation followed by sucrose density gradient centrifugation. Biochemical characterization included floatation pattern in sucrose gradients, acetylcholinesterase (AChE) activity and Western blot analysis for exosome-containing proteins. Exosomes were present in each of 23 amniotic fluids tested. They banded at a density of 1.17g/ml in sucrose gradients, were positive for AChE activity and contained tubulin, the inducible 72kDa heat shock protein, Hsp72 and the constitutively expressed heat shock protein, Hsc73; they were negative for calnexin. Exosome concentrations correlated positively with the number of pregnancies. Heat shock protein-containing exosomes are constituents of mid-trimester amniotic fluids and may contribute to immune regulation within the amniotic cavity.

  9. Origins of hydrodynamic forces on centrifugal pump impellers

    NASA Technical Reports Server (NTRS)

    Adkins, Douglas R.; Brennen, Christopher E.

    1987-01-01

    Hydrodynamic interactions that occur between a centrifugal pump impeller and volute are experimentally and theoretically investigated. The theoretical analysis considers the inability of the blades to perfectly guide the flow through the impeller, and also includes a quasi-one dimensional treatment of the flow in the volute. The disturbance at the impeller discharge and the resulting forces are determined by the theoretical model. The model is then extended to obtain the hydrodynamic force perturbations that are caused by the impeller whirling eccentrically in the volute. Under many operating conditions, these force perturbations were found to be destablizing. Comparisons are made between the theoretical model and the experimental measurements of pressure distributions and radial forces on the impeller. The theoretical model yields fairly accurate predictions of the radial forces caused by the flow through the impeller. However, it was found that the pressure acting on the front shroud of the impeller has a substantial effect on the destablizing hydrodynamic forces.

  10. Twinning of amphibian embryos by centrifugation

    NASA Technical Reports Server (NTRS)

    Black, S. D.

    1984-01-01

    In the frog Xenopus laevis, the dorsal structures of the embryonic body axis normally derive from the side of the egg opposite the side of sperm entry. However, if the uncleaved egg is inclined at lg or centrifuged in an inclined position, this topographic relationship is overridden: the egg makes its dorsal axial structures according to its orientation in the gravitational/centrifugal field, irrespective of the position of sperm entry. Certain conditions of centrifugation cause eggs to develop into conjoined twins with two sets of axial structures. A detailed analysis of twinning provided some insight into experimental axis orientation. First, as with single-axis embryos, both axes in twins are oriented according to the direction of centrifugation. One axis forms at the centripetal side of the egg and the other forms at the centrifugal side, even when the side of sperm entry is normal to the centrifugal force vector. Second, if eggs are centrifuged to give twins, but are inclined at lg to prevent post-centrifugation endoplasmic redistributions, only single-axis embryos develop. Thus, a second redistribution is required for high-frequency secondary axis formation. This can be accomplished by lg (as in the single centrifugations) or by a second centrifugation directed along the egg's animal-vegetal axis.

  11. Circadian rhythm of leaf movement in Capsicum annuum observed during centrifugation

    NASA Technical Reports Server (NTRS)

    Chapman, D. K.; Brown, A. H.; Dahl, A. O.

    1975-01-01

    Plant circadian rhythms of leaf movement in seedlings of the pepper plant (Capsicum annuum L., var. Yolo Wonder) were observed at different g-levels by means of a centrifuge. Except for the chronically imposed g-force all environmental conditions to which the plants were exposed were held constant. The circadian period, rate of change of amplitude of successive oscillations, symmetry of the cycles, and phase of the rhythm all were found not to be significantly correlated with the magnitude of the sustained g-force.

  12. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    PubMed Central

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  13. A Study of the Tolerance of ROK Air Force Personnel to Gz Centrifugation,

    DTIC Science & Technology

    1980-12-09

    A STUDY OF THE TOLERANCE OF ROK AIR FORCE PERSONNEL TO 6Z CENTR--ETC(U) DEC 80 B K LEE, J M HWANG, J S CHOIS UNCLASSIFIED FT-lrD(RS)T-1721-80 NL...DIVISION A STUDY OF THE TOLERANCE OF ROK AIR FORCE PERSONNEL TO+Gz CENTRIFUGATION by Byung Kook Lee, Jung Min Hwang, et al. 0 L..I IA - J Approved for public...Lieutenant Colonel 311 29 i94 1 2 6 Colonel 4 4 100 - Total j M7 1591’ 9 17 10 Conparin, the changes in heart rate of the pilots ar-d the ordinary per

  14. Experimental investigation on the effects of swirling flow on augmentor performance

    NASA Astrophysics Data System (ADS)

    Tan, Haoyuan; Huang, Xianjian

    1991-06-01

    This paper describes an investigation on the effect of centrifugal force distributions on swirl augmentor performance. The experiments were conducted on the flow drag, temperature-distribution efficiency in the swirl augmentor model with different tangential velocity profiles. Four tangential velocity distributions considered are the Rankine vortex, forced vortex, free vortex, and the constant-angle vortex. The results show that the flow drag of the Rankine vortex swirler is the smallest one, and, in a swirl augmentor where flame is stabilized by using centrifugal force, the combustion efficiency can reach 90 percent or over, though the swirl number is low (S = 0.25).

  15. Xylem vulnerability to cavitation can be accurately characterised in species with long vessels using a centrifuge method.

    PubMed

    Tobin, M F; Pratt, R B; Jacobsen, A L; De Guzman, M E

    2013-05-01

    Vulnerability to cavitation curves describe the decrease in xylem hydraulic conductivity as xylem pressure declines. Several techniques for constructing vulnerability curves use centrifugal force to induce negative xylem pressure in stem or root segments. Centrifuge vulnerability curves constructed for long-vesselled species have been hypothesised to overestimate xylem vulnerability to cavitation due to increased vulnerability of vessels cut open at stem ends that extend to the middle or entirely through segments. We tested two key predictions of this hypothesis: (i) centrifugation induces greater embolism than dehydration in long-vesselled species, and (ii) the proportion of open vessels changes centrifuge vulnerability curves. Centrifuge and dehydration vulnerability curves were compared for a long- and short-vesselled species. The effect of open vessels was tested in four species by comparing centrifuge vulnerability curves for stems of two lengths. Centrifuge and dehydration vulnerability curves agreed well for the long- and short-vesselled species. Centrifuge vulnerability curves constructed using two stem lengths were similar. Also, the distribution of embolism along the length of centrifuged stems matched the theoretical pressure profile induced by centrifugation. We conclude that vulnerability to cavitation can be accurately characterised with vulnerability curves constructed using a centrifuge technique, even in long-vesselled species. © 2012 German Botanical Society and The Royal Botanical Society of the Netherlands.

  16. Plasma membrane NADH oxidase of maize roots responds to gravity and imposed centrifugal forces

    NASA Technical Reports Server (NTRS)

    Bacon, E.; Morre, D. J.

    2001-01-01

    NADH oxidase activities measured with excised roots of dark-grown maize (Zea mays) seedlings and with isolated plasma membrane vesicles from roots of dark-grown maize oscillated with a regular period length of 24 min and were inhibited by the synthetic auxin 2,4-dichlorophenoxyacetic [correction of dichorophenoxyacetic] acid. The activities also responded to orientation with respect to gravity and to imposed centrifugal forces. Turning the roots upside down resulted in stimulation of the activity with a lag of about 10 min. Returning the sections to the normal upright position resulted in a return to initial rates. The activity was stimulated reversibly to a maximum of about 2-fold with isolated plasma membrane vesicles, when subjected to centrifugal forces of 25 to 250 x g for 1 to 4 min duration. These findings are the first report of a gravity-responsive enzymatic activity of plant roots inhibited by auxin and potentially related to the gravity-induced growth response. c2001 Editions scientifiques et medicales Elsevier SAS.

  17. Effects Of Gravitational Perturbation On The Expression Of Genes Regulating Metabolism In Jurkat Cells

    PubMed Central

    Singh, Kanika; Cubano, Luis; Lewis, Marian

    2015-01-01

    Gravitational perturbation altered gene expression and increased glucose consumption in spaceflown Jurkat cells. The purpose of this study was to determine if the acceleration experienced during launch was responsible for these changes. In ground-based studies, cells were subjected to typical launch centrifugal acceleration (3g of force for eight minutes) and centrifugal force of 90g for five minutes (commonly used to sediment cells) in a laboratory centrifuge. Controls consisted of static cultures. Gene expression was analyzed by RT-PCR. pH and glucose concentrations were evaluated to monitor metabolic changes. Comparison with controls indicated no significant change in pH or glucose use. Gene expression of Jurkat cells subjected to 3g or 90g of force was altered for only two genes out of seven tested. This research suggests that the changes observed in Jurkat cells flown on STS-95 were not a result of launch acceleration but to other conditions experienced during space flight. PMID:23875517

  18. Combination Of Investment And Centrifugal Casting

    NASA Technical Reports Server (NTRS)

    Creeger, Gordon A.

    1994-01-01

    Modifications, including incorporation of centrifugal casting, made in investment-casting process reducing scrap rate. Used to make first- and second-stage high-pressure-fuel-turbopump nozzles, containing vanes with thin trailing edges and other thin sections. Investment mold spun for short time while being filled, and stopped before solidification occurs. Centrifugal force drives molten metal into thin trailing edges, ensuring they are filled. With improved filling, preheat and pour temperatures reduced and solidification hastened so less hot tearing.

  19. Combining ergometer exercise and artificial gravity in a compact-radius centrifuge

    NASA Astrophysics Data System (ADS)

    Diaz, Ana; Trigg, Chris; Young, Laurence R.

    2015-08-01

    Humans experience physiological deconditioning during space missions, primarily attributable to weightlessness. Some of these adverse consequences include bone loss, muscle atrophy, sensory-motor deconditioning, and cardiovascular alteration, which may lead to orthostatic intolerance when astronauts return to Earth. Artificial gravity could provide a comprehensive countermeasure capable of challenging all the physiological systems at once, particularly if combined with exercise, thereby maintaining overall health during extended exposure to weightlessness. A new Compact Radius Centrifuge (CRC) platform was designed and built on the existing Short Radius Centrifuge (SRC) at the Massachusetts Institute of Technology (MIT). The centrifuge has been constrained to a radius of 1.4 m, the upper radial limit for a centrifuge to fit within an International Space Station (ISS) module without extensive structural alterations. In addition, a cycle ergometer has been added for exercise during centrifugation. The CRC now includes sensors of foot forces, cardiovascular parameters, and leg muscle electromyography. An initial human experiment was conducted on 12 subjects to analyze the effects of different artificial gravity levels (0 g, 1 g, and 1.4 g, measured at the feet) and ergometer exercise intensities (25 W warm-up, 50 W moderate and 100 W vigorous) on the musculoskeletal function as well as motion sickness and comfort. Foot forces were measured during the centrifuge runs, and subjective comfort and motion sickness data were gathered after each session. Preliminary results indicate that ergometer exercise on a centrifuge may be effective in improving musculoskeletal function. The combination is well tolerated and motion sickness is minimal. The MIT CRC is a novel platform for future studies of exercise combined with artificial gravity. This combination may be effective as a countermeasure to space physiological deconditioning.

  20. Analysis of Chromatin Organisation

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2011-01-01

    Terms to be familiar with before you start to solve the test: chromatin, nucleases, sucrose density gradient centrifugation, melting point, gel electrophoresis, ethidium bromide, autoradiography, Southern blotting, Northern blotting, Sanger sequencing, restriction endonucleases, exonucleases, linker DNA, chloroform extraction, nucleosomes,…

  1. Determination of buoyant density and sensitivity to chloroform and freon for the etiological agent of infectious salmonid anaemia

    USGS Publications Warehouse

    Christie, K.E.; Hjeltnes, B.; Uglenes , I.; Winton, J.R.

    1993-01-01

    Plasma was collected from Atlantic salmon Salrno salar with acute infectious salmon anaemia (ISA) and used to challenge Atlantic salmon parr by intraperitoneal injection. Treatment of plasma with the lipid solvent, chloroform, showed that the etiological agent of ISA contained essential lipids, probably as a viral envelope. Some infectivity remained following treatment with freon. Injection challenges using fractions from equilibrium density gradient centrifugation of plasma from fish with acute ISA revealed a band of infectivity in the range 1.184 to 1.262 g cm-3. The band was believed to conta~n both complete ISA-virus particles and infectious particles lacking a complete envelope, nucleocapsid or genome. Density gradient centrifugation of infectious plasma for enrichment of the putative ISA virus appeared to offer a suitable method for obtaining virus-specific nucleic acid for use in the construction of cDNA libraries. 

  2. Morphological evidence for phages in Xylella fastidiosa

    PubMed Central

    Chen, Jianchi; Civerolo, Edwin L

    2008-01-01

    Presumptive phage particles associated with Xylella fastidiosa strain Temecula-1 grown in PW broth were observed by transmission electron microscopy (TEM) in ultrathin sections of bacterial cell-containing low speed centrifugation pellets and in partially purified preparations from CsCl equilibrium centrifugation density gradients. Ultrathin-sectioned cell pellets contained icosahedral particles of about 45 nm in diameter. Samples collected from CsCl density gradients revealed mostly non-tailed icosahedral but also tailed particles. The icosahedral particles could be divided into two types: a large type (about 45 nm) and a small type (about 30 nm). Filamentous phage-like particles (17 × 120 to 6,300 nm) were also observed. The presence of different types of phage-like particles resembling to those in several bacteriophage families provides new physical evidence, in addition to X. fastidiosa genomic information, that X. fastidiosa possesses active phages. This is the first report of phage particles released in X. fastidiosa cultures. PMID:18538030

  3. Isolation and purification of a granulosis virus from infected larvae of the Indian meal moth, Plodia interpunctella.

    PubMed

    Tweeten, K A; Bulla, L A; Consigli, R A

    1977-09-01

    A procedure was developed for purification of a granulosis virus inclusion body produced in vivo in the Indian meal moth, Plodia interpunctella (Hübner). Purification was accomplished by differential centrifugation, treatment with sodium deoxycholate, and velocity sedimentation in sucrose gradients. The adequacy of the procedure was confirmed by mixing experiments in which uninfected, radioactively labeled larvae were mixed with infected, unlabeled larvae. After purification, the virus was shown to be free of host tissue, to retain its physical integrity, and to be highly infectious per os. Preparations of purified virus consisted of homogeneous populations of intact inclusion bodies (210 by 380 nm) whose buoyant density was 1.271 g/cm3 when centrifuged to equilibrium in sucrose gradients. Electron microscopy of thin-sectioned virus or of virus sequentially disrupted on electron microscope grids demonstrated three components: protein matrix, envelope, and nucleocapsid.

  4. Isolation and purification of a granulosis virus from infected larvae of the Indian meal moth, Plodia interpunctella.

    PubMed Central

    Tweeten, K A; Bulla, L A; Consigli, R A

    1977-01-01

    A procedure was developed for purification of a granulosis virus inclusion body produced in vivo in the Indian meal moth, Plodia interpunctella (Hübner). Purification was accomplished by differential centrifugation, treatment with sodium deoxycholate, and velocity sedimentation in sucrose gradients. The adequacy of the procedure was confirmed by mixing experiments in which uninfected, radioactively labeled larvae were mixed with infected, unlabeled larvae. After purification, the virus was shown to be free of host tissue, to retain its physical integrity, and to be highly infectious per os. Preparations of purified virus consisted of homogeneous populations of intact inclusion bodies (210 by 380 nm) whose buoyant density was 1.271 g/cm3 when centrifuged to equilibrium in sucrose gradients. Electron microscopy of thin-sectioned virus or of virus sequentially disrupted on electron microscope grids demonstrated three components: protein matrix, envelope, and nucleocapsid. Images PMID:334076

  5. Western blot (immunoblot) assay of small, round-structured virus associated with an acute gastroenteritis outbreak in Tokyo.

    PubMed

    Hayashi, Y; Ando, T; Utagawa, E; Sekine, S; Okada, S; Yabuuchi, K; Miki, T; Ohashi, M

    1989-08-01

    Small, round-structured virus (SRSV) was detected in a stool specimen of a patient during an acute gastroenteritis outbreak in Tokyo and was tentatively named SRSV-9. SRSV-9 was purified by sucrose velocity gradient centrifugation after CsCl density gradient centrifugation. The buoyant density of SRSV-9 appeared to be 1.36 g/ml in CsCl. A Western blot (immunoblot) assay using the biotin-avidin system revealed that SRSV-9 was antigenically related to the Hawaii agent but distinct from the Norwalk agent and contained a single major structural protein with a molecular size of 63.0 +/- 0.6 kilodaltons. The prevalence of SRSV-9 infection in Tokyo was surveyed by the Western blot antibody assay by using a crude virus preparation as the antigen. Seroconversion was observed in 56.5% of the patients involved in the outbreaks from which SRSV was detected by electron microscopy.

  6. Hydraulic conductivity of a sandy soil at low water content after compaction by various methods

    USGS Publications Warehouse

    Nimmo, John R.; Akstin, Katherine C.

    1988-01-01

    To investigate the degree to which compaction of a sandy soil influences its unsaturated hydraulic conductivity K, samples of Oakley sand (now in the Delhi series; mixed, thermic, Typic Xeropsamments) were packed to various densities and K was measured by the steady-state centrifuge method. The air-dry, machine packing was followed by centrifugal compression with the soil wet to about one-third saturation. Variations in (i) the impact frequency and (ii) the impact force during packing, and (iii) the amount of centrifugal force applied after packing, produced a range of porosity from 0.333 to 0.380. With volumetric water content θ between 0.06 and 0.12, K values were between 7 × 10−11 and 2 × 10−8 m/s. Comparisons of K at a single θ value for samples differing in porosity by about 3% showed as much as fivefold variation for samples prepared by different packing procedures, while there generally was negligible variation (within experimental error of 8%) where the porosity difference resulted from a difference in centrifugal force. Analysis involving capillary-theory models suggests that the differences in K can be related to differences in pore-space geometry inferred from water retention curves measured for the various samples.

  7. Numerical and experimental study on the steady cone-jet mode of electro-centrifugal spinning

    NASA Astrophysics Data System (ADS)

    Hashemi, Ali Reza; Pishevar, Ahmad Reza; Valipouri, Afsaneh; Pǎrǎu, Emilian I.

    2018-01-01

    This study focuses on a numerical investigation of an initial stable jet through the air-sealed electro-centrifugal spinning process, which is known as a viable method for the mass production of nanofibers. A liquid jet undergoing electric and centrifugal forces, as well as other forces, first travels in a stable trajectory and then goes through an unstable curled path to the collector. In numerical modeling, hydrodynamic equations have been solved using the perturbation method—and the boundary integral method has been implemented to efficiently solve the electric potential equation. Hydrodynamic equations have been coupled with the electric field using stress boundary conditions at the fluid-fluid interface. Perturbation equations were discretized by a second order finite difference method, and the Newton method was implemented to solve the discretized non-linear system. Also, the boundary element method was utilized to solve electrostatic equations. In the theoretical study, the fluid was described as a leaky dielectric with charges only on the surface of the jet traveling in dielectric air. The effect of the electric field induced around the nozzle tip on the jet instability and trajectory deviation was also experimentally studied through plate-plate geometry as well as point-plate geometry. It was numerically found that the centrifugal force prevails on electric force by increasing the rotational speed. Therefore, the alteration of the applied voltage does not significantly affect the jet thinning profile or the jet trajectory.

  8. Pasteurization of grapefruit juice using a centrifugal ultraviolet light irradiator

    USDA-ARS?s Scientific Manuscript database

    The pharmaceutical industry uses UV irradiators to inactivate viruses in liquids without heat. The penetration depth of UV in some liquids, such as serum plasma, can be short. To overcome this, very thin films may be produced by centrifugal force, small diameter tubing, or other means. Many liquid f...

  9. Density-Gradient Mediated Band Extraction of Leukocytes from Whole Blood Using Centrifugo-Pneumatic Siphon Valving on Centrifugal Microfluidic Discs

    PubMed Central

    Kearney, Sinéad M.; Kilcawley, Niamh A.; Early, Philip L.; Glynn, Macdara T.; Ducrée, Jens

    2016-01-01

    Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are ‘low-pass’, i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both ‘hydrostatically’ and ‘hydrodynamically’ triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, ‘dual siphon’ configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction. PMID:27167376

  10. Geotechnical centrifuge use at University of Cambridge Geotechnical Centre, August-September 1991

    NASA Astrophysics Data System (ADS)

    Gilbert, Paul A.

    1992-01-01

    A geotechnical centrifuge applies elevated acceleration to small-scale soil models to simulate body forces and stress levels characteristic of full-size soil structures. Since the constitutive behavior of soil is stress level development, the centrifuge offers considerable advantage in studying soil structures using models. Several experiments were observed and described in relative detail, including experiments in soil dynamics and liquefaction study, an experiment investigation leaning towers on soft foundations, and an experiment investigating migration of hot pollutants through soils.

  11. Biology Notes.

    ERIC Educational Resources Information Center

    School Science Review, 1980

    1980-01-01

    Outlines a variety of laboratory procedures, discussions, and demonstrations including in vitro contraction of muscle fibres and muscle proteins, sucrose density-gradient centrifugation, fern spore development, digestion of starch, construction of a small mammal trap, microscope selection, and occurrence and toxicity of mycotoxins. (GS)

  12. Automated cellular sample preparation using a Centrifuge-on-a-Chip.

    PubMed

    Mach, Albert J; Kim, Jae Hyun; Arshi, Armin; Hur, Soojung Claire; Di Carlo, Dino

    2011-09-07

    The standard centrifuge is a laboratory instrument widely used by biologists and medical technicians for preparing cell samples. Efforts to automate the operations of concentration, cell separation, and solution exchange that a centrifuge performs in a simpler and smaller platform have had limited success. Here, we present a microfluidic chip that replicates the functions of a centrifuge without moving parts or external forces. The device operates using a purely fluid dynamic phenomenon in which cells selectively enter and are maintained in microscale vortices. Continuous and sequential operation allows enrichment of cancer cells from spiked blood samples at the mL min(-1) scale, followed by fluorescent labeling of intra- and extra-cellular antigens on the cells without the need for manual pipetting and washing steps. A versatile centrifuge-analogue may open opportunities in automated, low-cost and high-throughput sample preparation as an alternative to the standard benchtop centrifuge in standardized clinical diagnostics or resource poor settings.

  13. Formation of thin film like assembly of exfoliated C3N4 nanoflakes by solvent non-evaporative method using centrifuge

    NASA Astrophysics Data System (ADS)

    Tejasvi, Ravi; Basu, Suddhasatwa

    2017-12-01

    A simple method for depositing a thin film of nanomaterial on a substrate using centrifugation technique has been developed, whereby solvent evaporation is prevented and solvent reuse is possible. The centrifuge technique of deposition yields uniform, smooth thin film irrespective of substrate surface texture. The deposited TiO2/eC3N4 film studied, through field emission scanning electron microscope, atomic force microscope, and optical surface profilometer, shows variation in surface roughness on the basis of centrifugation speeds. Initially film coverage improves and surface roughness decreases with the increase in rpm of the centrifuge and the surface roughness slightly increases with further increase in rpm. The photoelectrochemical studies of TiO2/eC3N4 films suggest that the centrifuge technique forms better heterojunctions compared to that by spin coating technique leading to enhanced photoelectrochemical water splitting.

  14. The Central Role of the Matrix Protein in Nipah Virus Assembly and Morphogenesis

    DTIC Science & Technology

    2007-03-23

    as determined by sucrose density gradient flotation and immunoprecipitation analysis. However, co-expression of F and G along with M revealed a...total protein detected (total lysate + supernatant). Experiments described in Chapter 4 did not 35 include a flotation step. Rather, following...culture supernatant were prepared as described above except the top 1.4 ml of the flotation gradient was mixed with 3 ml of PBS and centrifuged for an

  15. Centrifugal microfluidic platforms: advanced unit operations and applications.

    PubMed

    Strohmeier, O; Keller, M; Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N

    2015-10-07

    Centrifugal microfluidics has evolved into a mature technology. Several major diagnostic companies either have products on the market or are currently evaluating centrifugal microfluidics for product development. The fields of application are widespread and include clinical chemistry, immunodiagnostics and protein analysis, cell handling, molecular diagnostics, as well as food, water, and soil analysis. Nevertheless, new fluidic functions and applications that expand the possibilities of centrifugal microfluidics are being introduced at a high pace. In this review, we first present an up-to-date comprehensive overview of centrifugal microfluidic unit operations. Then, we introduce the term "process chain" to review how these unit operations can be combined for the automation of laboratory workflows. Such aggregation of basic functionalities enables efficient fluidic design at a higher level of integration. Furthermore, we analyze how novel, ground-breaking unit operations may foster the integration of more complex applications. Among these are the storage of pneumatic energy to realize complex switching sequences or to pump liquids radially inward, as well as the complete pre-storage and release of reagents. In this context, centrifugal microfluidics provides major advantages over other microfluidic actuation principles: the pulse-free inertial liquid propulsion provided by centrifugal microfluidics allows for closed fluidic systems that are free of any interfaces to external pumps. Processed volumes are easily scalable from nanoliters to milliliters. Volume forces can be adjusted by rotation and thus, even for very small volumes, surface forces may easily be overcome in the centrifugal gravity field which enables the efficient separation of nanoliter volumes from channels, chambers or sensor matrixes as well as the removal of any disturbing bubbles. In summary, centrifugal microfluidics takes advantage of a comprehensive set of fluidic unit operations such as liquid transport, metering, mixing and valving. The available unit operations cover the entire range of automated liquid handling requirements and enable efficient miniaturization, parallelization, and integration of assays.

  16. The Effect of Control Stiffness and Forward Speed on the Flutter of a 1/10-Scale Dynamic Model of a Two-Blade Jet-Driven Helicopter Rotor

    DTIC Science & Technology

    1955-04-01

    counterweights to adjust the blade static moment about the quarter chord, and the blade centrifugal forces are transferred to the hub by means of two...directly on a series of dials. The one-per-revolution rotor-speed timer consisted of a spring-loaded brush- contactor arrangement which effected a...moment which results when centrifugal forces act on the blade-retention straps. 8 NACA TN 3376 The results shown in figure 11, however, should be

  17. The comparison of the influence of centrifugal forces and the Sagnac effect on a rotating whispering gallery modes resonators

    NASA Astrophysics Data System (ADS)

    Filatov, Yuri V.; Shalymov, Egor V.; Venediktov, Vladimir Yu.; Dmitrieva, Anna D.

    2016-10-01

    The parameters of whispering gallery modes resonators can be significantly modified under the action of external factors, for instance, in the case of resonator movement. The effects, which take place in the moving resonators of whispering gallery modes, can be employed for measuring of the angular velocity. In this work we was compared the influence of centrifugal forces and the Sagnac effect on the eigenfrequencies (wavelengths) of whispering gallery modes resonators. Also work is devoted mutual relationships of the effects.

  18. Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis.

    PubMed

    Masuzawa, Toru; Ohta, Akiko; Tanaka, Nobuatu; Qian, Yi; Tsukiya, Tomonori

    2009-01-01

    The effect of the hydraulic force on magnetically levitated (maglev) pumps should be studied carefully to improve the suspension performance and the reliability of the pumps. A maglev centrifugal pump, developed at Ibaraki University, was modeled with 926 376 hexahedral elements for computational fluid dynamics (CFD) analyses. The pump has a fully open six-vane impeller with a diameter of 72.5 mm. A self-bearing motor suspends the impeller in the radial direction. The maximum pressure head and flow rate were 250 mmHg and 14 l/min, respectively. First, a steady-state analysis was performed using commercial code STAR-CD to confirm the model's suitability by comparing the results with the real pump performance. Second, transient analysis was performed to estimate the hydraulic force on the levitated impeller. The impeller was rotated in steps of 1 degrees using a sliding mesh. The force around the impeller was integrated at every step. The transient analysis revealed that the direction of the radial force changed dynamically as the vane's position changed relative to the outlet port during one circulation, and the magnitude of this force was about 1 N. The current maglev pump has sufficient performance to counteract this hydraulic force. Transient CFD analysis is not only useful for observing dynamic flow conditions in a centrifugal pump but is also effective for obtaining information about the levitation dynamics of a maglev pump.

  19. Centrifuge advances using HTS magnetic bearings

    NASA Astrophysics Data System (ADS)

    Werfel, F. N.; Flögel-Delor, U.; Rothfeld, R.; Wippich, D.; Riedel, T.

    2001-05-01

    Passive magnetic bearings are of increasing technical interest. We performed experiments with centrifugal rotors to analyze gyroscopic forces in terms imbalance, rotor elasticity and damping. Centrifuge rotors need to be operated soft and stable without whirling the sediments. In order to evaluate optimal parameters critical and resonance behaviors are investigated. Eccentricities up 2 mm are safely passed by accelerating test wheels. In a simple model we describe the effect of passing critical rotational speeds. Measurements of bearing properties and wheel performance are presented. We have constructed a first prototype centrifuge designed with a HTS double bearing which operates a titanium rotor safely up to 30 000 rpm. A 15 W Stirling cooler serves cryogenics of the YBCO stators. From the experiments design guidelines for centrifugal applications with HTS bearings are given.

  20. Spatial orientation and balance control changes induced by altered gravitoinertial force vectors

    NASA Technical Reports Server (NTRS)

    Kaufman, G. D.; Wood, S. J.; Gianna, C. C.; Black, F. O.; Paloski, W. H.

    2001-01-01

    To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

  1. Spatial orientation and balance control changes induced by altered gravitoinertial force vectors.

    PubMed

    Kaufman, G D; Wood, S J; Gianna, C C; Black, F O; Paloski, W H

    2001-04-01

    To better understand the mechanisms of human adaptation to rotating environments, we exposed 19 healthy subjects and 8 vestibular-deficient subjects ("abnormal"; four bilateral and four unilateral lesions) to an interaural centripetal acceleration of 1 g (resultant 45 degrees roll-tilt of 1.4 g) on a 0.8-m-radius centrifuge for periods of 90 min. The subjects sat upright (body z-axis parallel to centrifuge rotation axis) in the dark with head stationary, except during 4 min of every 10 min, when they performed head saccades toward visual targets switched on at 3- to 5-s intervals at random locations (within +/- 30 degrees) in the earth-horizontal plane. Eight of the normal subjects also performed the head saccade protocol in a stationary chair adjusted to a static roll-tilt angle of 45 degrees for 90 min (reproducing the change in orientation but not the magnitude of the gravitoinertial force on the centrifuge). Eye movements, including voluntary saccades directed along perceived earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation. Postural center of pressure (COP) and multisegment body kinematics were also gathered before and within 10 min after centrifugation. Normal subjects overestimated roll-tilt during centrifugation and revealed errors in perception of head-vertical provided by directed saccades. Errors in this perceptual response tended to increase with time and became significant after approximately 30 min. Motion-sickness symptoms caused approximately 25% of normal subjects to limit their head movements during centrifugation and led three normal subjects to stop the test early. Immediately after centrifugation, subjects reported feeling tilted 10 degrees in the opposite direction, which was in agreement with the direction of their earth-referenced directed saccades. Postural COP, segmental body motion amplitude, and hip-sway frequency increased significantly after centrifugation. These postural effects were short-lived, however, with a recovery time of several postural test trials (minutes). There were also asymmetries in the direction of postcentrifugation COP and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). The amount of total head movements during centrifugation correlated poorly or inversely with postcentrifugation postural stability, and the most unstable subject made no head movements. There was no decrease in postural stability after static tilt, although these subjects also reported a perceived tilt briefly after return to upright, and they also had COP asymmetries. Abnormal subjects underestimated roll-tilt during centrifugation, and their directed saccades revealed permanent spatial distortions. Bilateral abnormal subjects started out with poor postural control, but showed no postural decrements after centrifugation, while unilateral abnormal subjects had varying degrees of postural decrement, both in their everyday function and as a result of experiencing the centrifugation. In addition, three unilateral, abnormal subjects, who rode twice in opposite orientations, revealed a consistent orthogonal pattern of COP offsets after centrifugation. These results suggest that both orientation and magnitude of the gravitoinertial vector are used by the central nervous system for calibration of multiple orientation systems. A change in the background gravitoinertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

  2. Macro and micro rate zonal analytical centrifugation of polydisperse and slowly diffusing sedimenting systems in isovolumetric density gradients. Application to cartilage proteoglycans.

    PubMed

    Müller, F J; Pezon, C F; Pita, J C

    1989-06-13

    A method to study the polydispersity of zonally sedimenting and slowly diffusing macromolecules or particles in isokinetic or isovolumetric density gradients is presented. First, a brief theory is given for predicting the zonal profile after a "triangular" (or "inverse") zone is centrifuged. This type of zone is essential to preserve hydrodynamic stability of the very slowly diffusing polydisperse solutes. It is proven, both by semitheoretical considerations and by computer calculations, that the resulting concentration profile of macrosolute is almost identical with that obtainable with a rectangular zone coextensive with the triangular one and carrying the same total mass. Next, practical procedures are described for the convectionless layering of very small triangular zones (50 microL or less). The linearity and stability of the zones are experimentally tested and verified. Finally, the method is applied to cartilage proteoglycan preparations that included either the monomeric molecules only or both the monomeric and the aggregated ones. The zonal results are compared with those obtained by using conventional boundary sedimentation. The two sets of results are seen to coincide fairly well, thus proving that the present technique can add to preparative zonal centrifugation the analytical precision of boundary sedimentation. A multimodal polydisperse system is suggested to describe the aggregated proteoglycan macromolecules.

  3. Degradation of surfactant-associated protein B (SP-B) during in vitro conversion of large to small surfactant aggregates.

    PubMed Central

    Veldhuizen, R A; Inchley, K; Hearn, S A; Lewis, J F; Possmayer, F

    1993-01-01

    Pulmonary surfactant obtained from lung lavages can be separated by differential centrifugation into two distinct subfractions known as large surfactant aggregates and small surfactant aggregates. The large-aggregate fraction is the precursor of the small-aggregate fraction. The ratio of the small non-surface-active to large surface-active surfactant aggregates increases after birth and in several types of lung injury. We have utilized an in vitro system, surface area cycling, to study the conversion of large into small aggregates. Small aggregates generated by surface area cycling were separated from large aggregates by centrifugation at 40,000 g for 15 min rather than by the normal sucrose gradient centrifugation. This new separation method was validated by morphological studies. Surface-tension-reducing activity of total surfactant extracts, as measured with a pulsating-bubble surfactometer, was impaired after surface area cycling. This impairment was related to the generation of small aggregates. Immunoblot analysis of large and small aggregates separated by sucrose gradient centrifugation revealed the presence of detectable amounts of surfactant-associated protein B (SP-B) in large aggregates but not in small aggregates. SP-A was detectable in both large and small aggregates. PAGE of cycled and non-cycled surfactant showed a reduction in SP-B after surface area cycling. We conclude that SP-B is degraded during the formation of small aggregates in vitro and that a change in surface area appears to be necessary for exposing SP-B to protease activity. Images Figure 2 Figure 5 Figure 6 Figure 7 PMID:8216208

  4. A theoretical study of fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser

    NASA Technical Reports Server (NTRS)

    Tsujimoto, Yoshinobu; Acosta, Allan J.; Yoshida, Yoshiki

    1989-01-01

    The fluid forces on a centrifugal impeller rotating and whirling in a vaned diffuser are analyzed on the assumption that the number of impeller and diffuser vanes is so large that the flows are perfectly guided by the vanes. The flow is taken to be two dimensional, inviscid, and incompressible, but the effects of impeller and diffuser losses are taken into account. It is shown that the interaction with the vaned diffuser may cause destabilizing fluid forces. From these discussions, it is found that the whirling forces are closely related to the steady head-capacity characteristics of the impeller. This physical understanding of the whirling forces can be applied also to the cases with volute casings. At partial capacities, it is shown that the impeller forces change greatly when the flow rate and whirl velocity are near to the impeller or vaned diffuser attributed rotating stall onset capacity, and the stall propagation velocity, respectively. In such cases the impeller forces may become destabilizing for impeller whirl.

  5. Multiple direction vibration fixture

    DOEpatents

    Cericola, Fred; Doggett, James W.; Ernest, Terry L.; Priddy, Tommy G.

    1991-01-01

    An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.

  6. Transient disturbance growth in flows over convex surfaces

    NASA Astrophysics Data System (ADS)

    Karp, Michael; Hack, M. J. Philipp

    2017-11-01

    Flows over curved surfaces occur in a wide range of applications including airfoils, compressor and turbine vanes as well as aerial, naval and ground vehicles. In most of these applications the surface has convex curvature, while concave surfaces are less common. Since monotonic boundary-layer flows over convex surfaces are exponentially stable, they have received considerably less attention than flows over concave walls which are destabilized by centrifugal forces. Non-modal mechanisms may nonetheless enable significant disturbance growth which can make the flow susceptible to secondary instabilities. A parametric investigation of the transient growth and secondary instability of flows over convex surfaces is performed. The specific conditions yielding the maximal transient growth and strongest instability are identified. The effect of wall-normal and spanwise inflection points on the instability process is discussed. Finally, the role and significance of additional parameters, such as the geometry and pressure gradient, is analyzed.

  7. Suppression of morphogenesis in embryonic mouse limbs exposed in vitro to excess gravity.

    PubMed

    Duke, J C

    1983-06-01

    This paper is a report of the first investigation of the effect of excess gravity on in vitro mammalian limb chondrogenesis. Limb buds from mice of various gestational stages were exposed to excess gravity (2.6G) using a culture centrifuge. Both forelimbs and hind limbs were cultured and the development of various limb elements was scored after four to six days. The 2.6G force significantly depressed the development of limb elements when applied during the teratogen-sensitive period of chondrogenesis. There was a proximodistal gradient of sensitivity to excess gravity in the limb with proximal structures being less susceptible than distal ones. In some cases, proximal limb elements present prior to explantation disappeared upon exposure to excess gravity. Hypergravity's teratogenic effect is assumed to operate via changes in tension and/or pressure on the cells, accompanied by alterations in cell morphometry and membrane properties.

  8. Spiral counter-current chromatography: Design, development, application, and challenges.

    PubMed

    Huang, Xin-Yi; Sun, Xiao-Ming; Pei, Dong; Di, Duo-Long

    2017-01-01

    Depending on the rapid growth in the radial gradient of the centrifugal force, spiral counter-current chromatography can greatly improve the retention of stationary phase, especially for the aqueous two-phase systems with ultra-polar and high viscosity that are not well retained in the conventional multilayer coils counter-current chromatography. As a result, it is an attractive and alternative technology that is suited for separation of hydrophilic compounds and has led to many exciting progress in recent years. This review presents the recent advances and applications of spiral counter-current chromatography, including its major benefits and limitations, some novel methods to improve the separation efficiency and its applications in separation of real samples. In addition, the remaining challenges and future perspectives on development of spiral counter-current chromatography also are proposed in this article. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Separation of cells from the rat anterior pituitary gland

    NASA Technical Reports Server (NTRS)

    Hymer, Wesley C.; Hatfield, J. Michael

    1983-01-01

    Various techniques for separating the hormone-producing cell types from the rat anterior pituitary gland are examined. The purity, viability, and responsiveness of the separated cells depend on the physiological state of the donor, the tissue dissociation procedures, the staining technique used for identification of cell type, and the cell separation technique. The chamber-gradient setup and operation, the characteristics of the gradient materials, and the separated cell analysis of velocity sedimentation techniques (in particular Staput and Celsep) are described. Consideration is given to the various types of materials used in density gradient centrifugation and the operation of a gradient generating device. The use of electrophoresis to separate rat pituitary cells is discussed.

  10. Changes in the structures of motile sperm subpopulations in dog spermatozoa after both cryopreservation and centrifugation on PureSperm(®) gradient.

    PubMed

    Dorado, J; Alcaráz, L; Duarte, N; Portero, J M; Acha, D; Hidalgo, M

    2011-05-01

    The aims of the present study were to: (1) determine if discrete motile sperm subpopulations exist and their incidence in fresh dog ejaculates, (2) evaluate the effects of cryopreservation on the distribution of spermatozoa within the different subpopulations, and (3) determine the effect of the discontinuous PureSperm(®) gradient on the sperm subpopulation structure of frozen-thawed dog spermatozoa. Semen from 5 dogs were collected and cryopreserved following a standard protocol. After thawing, semen samples were selected by centrifugation on PureSperm(®). Sperm motility (assessed by computerized-assisted semen analysis, CASA) was assessed before freezing, just after thawing and after preparation on the PureSperm(®) gradients. Cryopreservation had a significant (P<0.001) effect on CASA-derived parameters. PureSperm(®) centrifugation yielded sperm suspensions with improved motility (P<0.01). A multivariate clustering procedure separated 19414 motile spermatozoa into four subpopulations: Subpopulation 1 consisting of poorly active and non-progressive spermatozoa (20.97%), Subpopulation 2 consisting of slow and low-linear spermatozoa (18.24%), Subpopulation 3 consisting of highly active but non-progressive spermatozoa (20.75%), and Subpopulation 4 consisting of high speed and progressive spermatozoa (40.03%). Although, cryopreservation had a significant (P<0.001) effect on both the frequency distribution of spermatozoa within subpopulations and the motion characteristics of each subpopulation, the sperm subpopulation structure was perfectly maintained after freezing and thawing. The selected sperm samples was enrich in Subpopulation 4, reaching a proportion of 31.9% of the present spermatozoa, in contrast with the unselected sperm samples, where this sperm subpopulation accounted for 24.9% of the total. From these results, we concluded that four well-defined motile sperm subpopulations were present either in fresh semen, in unselected sperm samples or in selected preparations from dogs. The discontinuous PureSperm(®) gradient is a simple method to improve the quality of canine frozen-thawed semen samples, since Subpopulation 4 (high-speed and progressive spermatozoa) was more frequently observed after preparation on the gradient. Finally, this study also demonstrated that the general motile sperm structure present in dog remains constant despite the effect caused by either cryopreservation or separation on PureSperm(®) gradient. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Gamma-glutamyltransferase activity in exosomes as a potential marker for prostate cancer.

    PubMed

    Kawakami, Kyojiro; Fujita, Yasunori; Matsuda, Yoko; Arai, Tomio; Horie, Kengo; Kameyama, Koji; Kato, Taku; Masunaga, Koichi; Kasuya, Yutaka; Tanaka, Masashi; Mizutani, Kosuke; Deguchi, Takashi; Ito, Masafumi

    2017-05-05

    Exosomes or extracellular vesicles have the potential as a diagnostic marker for various diseases including cancer. In order to identify novel exosomal markers for prostate cancer (PC), we performed proteomic analysis of exosomes isolated from PC cell lines and examined the usefulness of the marker in patients. Exosomes isolated by differential centrifugation from the culture medium of androgen-dependent LNCaP prostate cancer cell line and its sublines of partially androgen-independent C4, androgen-independent C4-2 and bone metastatic C4-2B were subjected to iTRAQ-based proteomic analysis. Exosomes were also isolated by immunocapture and separated by size exclusion chromatography and density gradient centrifugation. Protein expression was determined by Western blot analysis. GGT activity was measured using a fluorescent probe, γ-glutamyl hydroxymethyl rhodamine green (gGlu-HMRG). Immunohistochemical analysis of tissues was performed using anti-GGT1 antibody. Among proteins upregulated in C4-2 and C4-2B cells than in LNCaP cells, we focused on gamma-glutamyltransferase 1 (GGT1), a cell-surface enzyme that regulates the catabolism of extracellular glutathione. The levels of both GGT1 large and small subunits were elevated in exosomes isolated from C4-2 and C4-2B cells by differential centrifugation and by immunocapture with anti-CD9 or -prostate-specific membrane antigen (PSMA) antibody. In cell lysates and exosomes, GGT1 expression correlated with GGT activity. Size exclusion chromatography of human serum demonstrated the presence of GGT activity and GGT1 subunits in fractions positive for CD9. Density gradient centrifugation revealed the co-presence of GGT1 subunits with CD9 in exosomes isolated by differential centrifugation from human serum. Since GGT activity correlated with GGT1 expression in serum exosomes isolated by differential centrifugation, we measured serum exosomal GGT activity in patients. Unexpectedly, we found that serum exosomal GGT activity was significantly higher in PC patients than in benign prostatic hyperplasia (BPH) patients. In support of this finding, immunohistochemical analysis showed increased GGT1 expression in PC tissues compared with BPH tissues. Our results suggest that serum exosomal GGT activity could be a useful biomarker for PC.

  12. Medical Monitoring during Short Radius Centrifugation in Bed-rested Subjects

    NASA Technical Reports Server (NTRS)

    Reinertson, Randal; Nelson, Victor; Aunon, Serena; Schlegel, Todd; Paloski, William

    2007-01-01

    The artificial gravity pilot project was designed to investigate the efficacy of daily exposure to a Gz acceleration gradient for counteracting the physiologic decrements induced by prolonged bed rest. A short radius centrifuge was used to produce a Gz gradient such that 1 g was applied at the level of the subject s heart and 2.5 g at the feet. For inclusion in the study, subjects were required to complete a 75-minute screening spin on the centrifuge. During the study, each active treatment subject was scheduled for a 60-minute spin each day for 20 consecutive days. During centrifugation, subjects were continuously monitored by a physician for signs and symptoms of pre-syncope, motion sickness, arrhythmias, joint/muscle pain and any other unanticipated problems. The physician was also present to provide emergency care in the case of a medical emergency. Cameras mounted on the centrifuge were used to provide a means of observing the subject s face and torso. Audio communication was continuously maintained. Other monitoring tools included two-lead EKG tracings, pulse oximetry, intermittent sphygmomanometer readings, lights in the peripheral visual field, and continuous blood pressure readout from a tonometry device. Thirty screening runs were attempted using twenty-seven subjects. Seven of these runs were terminated early for symptoms of pre-syncope, motion sickness, or GI distress. A total of eight subjects completed the active treatment arm of the study. Of the 160 centrifuge runs that were scheduled for these eight treatment subjects, 152 were completed, seven were terminated early, and one was not attempted. Of the seven early terminations, four were related to symptoms of pre-syncope, one to leg pain, one to GI discomfort, and one to equipment failure. Three terminations for adverse symptoms occurred on the first treatment day. Three terminations occurred on day nineteen of treatment and within 24 hours after scheduled soleus and quadriceps muscle biopsies. We have summarized the relative usefulness of the information obtained by the various monitoring modalities in making a decision to terminate a centrifuge run. The video and audio communication information was essential to the decision-making process. Heart rate and EKG tracings are considered valuable, even though no spins were terminated due to significant arrhythmias. The tonometer device was generally not reliable in this application. Our observations suggest that subjects may be less tolerant of centrifugation just after starting bed rest and after invasive procedures.

  13. Compressible Convection Experiment using Xenon Gas in a Centrifuge

    NASA Astrophysics Data System (ADS)

    Menaut, R.; Alboussiere, T.; Corre, Y.; Huguet, L.; Labrosse, S.; Deguen, R.; Moulin, M.

    2017-12-01

    We present here an experiment especially designed to study compressible convection in the lab. For significant compressible convection effects, the parameters of the experiment have to be optimized: we use xenon gaz in a cubic cell. This cell is placed in a centrifuge to artificially increase the apparent gravity and heated from below. With these choices, we are able to reach a dissipation number close to Earth's outer core value. We will present our results for different heating fluxes and rotation rates. We success to observe an adiabatic gradient of 3K/cm in the cell. Studies of pressure and temperature fluctuations lead us to think that the convection takes place under the form of a single roll in the cell for high heating flux. Moreover, these fluctuations show that the flow is geostrophic due to the high rotation speed. This important role of rotation, via Coriolis force effects, in our experimental setup leads us to develop a 2D quasigeostrophic compressible model in the anelastic liquid approximation. We test numerically this model with the finite element solver FreeFem++ and compare its results with our experimental data. In conclusion, we will present our project for the next experiment in which the cubic cell will be replace by a annulus cell. We will discuss the new expected effects due to this geometry as Rossby waves and zonal flows.

  14. Gas dynamics in strong centrifugal fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bogovalov, S.V.; Kislov, V.A.; Tronin, I.V.

    2015-03-10

    Dynamics of waves generated by scopes in gas centrifuges (GC) for isotope separation is considered. The centrifugal acceleration in the GC reaches values of the order of 106g. The centrifugal and Coriolis forces modify essentially the conventional sound waves. Three families of the waves with different polarisation and dispersion exist in these conditions. Dynamics of the flow in the model GC Iguasu is investigated numerically. Comparison of the results of the numerical modelling of the wave dynamics with the analytical predictions is performed. New phenomena of the resonances in the GC is found. The resonances occur for the waves polarizedmore » along the rotational axis having the smallest dumping due to the viscosity.« less

  15. Physics that Textbook Writers Usually Get Wrong: III.

    ERIC Educational Resources Information Center

    Bauman, Robert P.

    1992-01-01

    Examines inconsistencies in science textbook discussions of vector quantities and force. Provides illustrations of textbook inconsistencies related to Newton's laws of motion and the concepts of centrifugal and coriolis force. (MDH)

  16. Limited use of Centritech Lab II Centrifuge in perfusion culture of rCHO cells for the production of recombinant antibody.

    PubMed

    Kim, Byoung Jin; Oh, Duk Jae; Chang, Ho Nam

    2008-01-01

    Perfusion cultures of recombinant Chinese hamster ovary cells, producing recombinant antibody against the S surface antigen of Hepatitis B virus, were carried out in continuous and intermittent mode using a Centritech Lab II Centrifuge. In the continuous perfusion process, despite the absence of shear stress from the pump head, long-term operation was not possible because of continuously repeated exposure to oxygen limitation and low temperature, as well as shear stress from centrifugal force. In the intermittent perfusion processes, the frequency of cell-passage through the centrifuge was substantially reduced, compared with the continuous perfusion mode; however, the degree of reduction could not guarantee stable long-term operation. Although various operating parameters were applied in the intermittent perfusion cultures, high cell densities could not be maintained stably. In a single bioreactor culture system, a specific cell that is returned from the centrifuge to the bioreactor could be transferred from the bioreactor to the centrifuge again in the next cycle. These repetitive damages, caused by shear stress from the pump head and centrifugal force, as well as exposure to suboptimal conditions such as oxygen limitation and low temperature below 37 degrees C, were more serious at higher perfusion rates. Subsequently, damaged cells and dead cells were continuously accumulated in the bioreactor. Culture temperature shift from 37 to 33 degrees C increased antibody concentrations but showed inhibitory effects on cell growth. The negative effects of lowering culture temperature on cell growth overwhelmed the positive effects on antibody production. To protect cells from shear stress, Pluronic F-68 was 2-fold concentrated in the culture medium; nevertheless, a significantly higher concentration of Pluronic F-68 (2 g/L) may have inhibitory effects on cell growth.

  17. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes

    PubMed Central

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B.; Kipman, Ulrike; Felder, Thomas K.; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M.; Haschke-Becher, Elisabeth

    2017-01-01

    Introduction Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. Materials and methods We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. Results High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to < 0.001) and lower bicarbonate values (P = 0.049 to 0.008) in the latter. Conclusions Serum and heparin samples may be centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed. PMID:29187797

  18. Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes.

    PubMed

    Cadamuro, Janne; Mrazek, Cornelia; Leichtle, Alexander B; Kipman, Ulrike; Felder, Thomas K; Wiedemann, Helmut; Oberkofler, Hannes; Fiedler, Georg M; Haschke-Becher, Elisabeth

    2018-02-15

    Although centrifugation is performed in almost every blood sample, recommendations on duration and g-force are heterogeneous and mostly based on expert opinions. In order to unify this step in a fully automated laboratory, we aimed to evaluate different centrifugation settings and their influence on the results of routine clinical chemistry analytes. We collected blood from 41 healthy volunteers into BD Vacutainer PST II-heparin-gel- (LiHepGel), BD Vacutainer SST II-serum-, and BD Vacutainer Barricor heparin-tubes with a mechanical separator (LiHepBar). Tubes were centrifuged at 2000xg for 10 minutes and 3000xg for 7 and 5 minutes, respectively. Subsequently 60 and 21 clinical chemistry analytes were measured in plasma and serum samples, respectively, using a Roche COBAS instrument. High sensitive Troponin T, pregnancy-associated plasma protein A, ß human chorionic gonadotropin and rheumatoid factor had to be excluded from statistical evaluation as many of the respective results were below the measuring range. Except of free haemoglobin (fHb) measurements, no analyte result was altered by the use of shorter centrifugation times at higher g-forces. Comparing LiHepBar to LiHepGel tubes at different centrifugation setting, we found higher lactate-dehydrogenase (LD) (P = 0.003 to < 0.001) and lower bicarbonate values (P = 0.049 to 0.008) in the latter. Serum and heparin samples may be centrifuged at higher speed (3000xg) for a shorter amount of time (5 minutes) without alteration of the analytes tested in this study. When using LiHepBar tubes for blood collection, a separate LD reference value might be needed.

  19. [Isolation and purification of primary Kupffer cells from mouse liver].

    PubMed

    Sun, Chao; Luo, Qingbo; Lu, Xiuxian; Zheng, Daofeng; He, Diao; Wu, Zhongjun

    2016-08-01

    Objective To isolate and purify Kupffer cells (KCs) from BALB/c mice by an efficient method of low-speed centrifugation and rapid adherence. Methods The mouse liver tissue was perfused in situ and digested with 0.5 g/L collagenase type IV in vitro by water bath. Then, through the low-speed centrifugation, KCs were separated from the mixed hepatocytes, and purified by rapid adherent characteristics. Finally, the production and activity of KCs obtained by this modified method were compared with those isolated by Percoll density gradient centrifugation. We used F4/80 antibody immunofluorescence technique to observe morphological features of KCs, flow cytometry (FCM) to detect the expression of F4/80 antibody and the ink uptake test to observe the phagocytic activity. Moreover, using FCM, we evaluated the expressions of molecules associated with antigen presentation, including major histocompatibility complex class II (MHC II), CD40, CD86 and CD68 on the surface of KCs subjected to hypoxia/reoxygenation (H/R) modeling. And, ELISA was conducted to measure tumor necrosis factor-α (TNF-α) production of the cultured KCs following H/R. Results The yield of KCs was (5.83±0.54)×10(6) per mouse liver and the survival rate of KCs was up to 92% by low-speed centrifugation and rapid adherent method. Compared with Percoll density gradient centrifugation [the yield of KCs was (2.19±0.43)×10(6) per liver], this new method significantly improved the yield of KCs. F4/80 immunofluorescence showed typical morphologic features of KCs such as spindle or polygon shapes and FCM identified nearly 90% F4/80 positive cells. The phagocytic assay showed that lots of ink particles were phagocytosed into the isolated cells. KC H/R models expressed more MHC II, CD40 and CD86 and produced more TNF-α participating in inflammation. Conclusion The efficient method to isolate and purify KCs from BALB /c mice has been successfully established.

  20. Influence of permittivity on gradient force exerted on Mie spheres.

    PubMed

    Chen, Jun; Li, Kaikai; Li, Xiao

    2018-04-01

    In optical trapping, whether a particle could be stably trapped into the focus region greatly depends on the strength of the gradient force. Individual theoretical study on gradient force exerted on a Mie particle is rare because the mathematical separation of the gradient force and the scattering force in the Mie regime is difficult. Based on the recent forces separation work by Du et al. [Sci. Rep.7, 18042 (2017)SRCEC32045-232210.1038/s41598-017-17874-1], we investigate the influence of permittivity (an important macroscopic physical quantity) on the gradient force exerted on a Mie particle by cooperating numerical calculation using fast Fourier transform and analytical analysis using multipole expansion. It is revealed that gradient forces exerted on small spheres are mainly determined by the electric dipole moment except for certain permittivity with which the real part of polarizability of the electric dipole approaches zero, and gradient forces exerted on larger spheres are complex because of the superposition of the multipole moments. The classification of permittivity corresponding to different varying tendencies of gradient forces exerted on small spheres or larger Mie particles are illustrated. Absorption of particles favors the trapping of small spheres by gradient force, while it is bad for the trapping of larger particles. Moreover, the absolute values of the maximal gradient forces exerted on larger Mie particles decline greatly versus the varied imaginary part of permittivity. This work provides elaborate investigation on the different varying tendencies of gradient forces versus permittivity, which favors more accurate and free optical trapping.

  1. ISOLATION OF CHICKEN FOLLICULAR DENDRITIC CELLS

    USDA-ARS?s Scientific Manuscript database

    The aim of the present study was to isolate chicken follicular dendritic cells (FDC). A combination of methods involving panning, iodixanol density gradient centrifugation, and magnetic cell separation technology made it possible to obtain functional FDC from the cecal tonsils from chickens, which h...

  2. The use of centrifugation to study early Drosophila embryogenesis

    NASA Technical Reports Server (NTRS)

    Abbott, M. K.; Spooner, B. S. (Principal Investigator)

    1993-01-01

    By the end of 10th nuclear cycle, the somatic nuclei of the Drosophila embryo have migrated to the periphery of the egg. Centrifugation of embryos did not result in the displacement of these nuclei, since cytoskeletal elements anchor them to the cortex. But, mild centrifugal forces displace the centrally located, nascent yolk nuclei. If this increased sensitivity to hypergravity occurs before the beginning of nuclear differentiation during cycle 8, when the nascent yolk and somatic nuclei physically separate, then it would mark the earliest functional difference between these two lineages.

  3. 24. RW Meyer Sugar Mill: 18761889. Centrifugal inner basket, 1879. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. RW Meyer Sugar Mill: 1876-1889. Centrifugal inner basket, 1879. Manufacturer, unknown. Supplied by Honolulu Iron Works, Honolulu, Hawaii, 1879. View: After sugar was granulated and cooled it was dried and drained, completely separating the sugar crystals from the molasses, in the centrifugal. Revolving at 1200 rpm the sugar charge was forced outward with the molasses flying through the holes in the brass lining. Dried sugar was left behind in the inner basket and was dug out by hand. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  4. Tolerance of centrifuge-simulated suborbital spaceflight by medical condition.

    PubMed

    Blue, Rebecca S; Pattarini, James M; Reyes, David P; Mulcahy, Robert A; Garbino, Alejandro; Mathers, Charles H; Vardiman, Johnené L; Castleberry, Tarah L; Vanderploeg, James M

    2014-07-01

    We examined responses of volunteers with known medical disease to G forces in a centrifuge to evaluate how potential commercial spaceflight participants (SFPs) might tolerate the forces of spaceflight despite significant medical history. Volunteers were recruited based upon suitability for each of five disease categories (hypertension, cardiovascular disease, diabetes, lung disease, back or neck problems) or a control group. Subjects underwent seven centrifuge runs over 2 d. Day 1 consisted of two +G(z) runs (peak = +3.5 G(z), Run 2) and two +G(x), runs (peak = +6.0 G(x), Run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +G(x) and +G(z), peak = +6.0 G(x)/+4.0 G(z)). Data collected included blood pressure, electrocardiogram, pulse oximetry, neurovestibular exams, and post-run questionnaires regarding motion sickness, disorientation, grayout, and other symptoms. A total of 335 subjects registered for participation, of which 86 (63 men, 23 women, age 20-78 yr) participated in centrifuge trials. The most common causes for disqualification were weight and severe and uncontrolled medical or psychiatric disease. Five subjects voluntarily withdrew from the second day of testing: three for anxiety reasons, one for back strain, and one for time constraints. Maximum hemodynamic values recorded included HR of 192 bpm, systolic BP of 217 mmHg, and diastolic BP of 144 mmHg. Common subjective complaints included grayout (69%), nausea (20%), and chest discomfort (6%). Despite their medical history, no subject experienced significant adverse physiological responses to centrifuge profiles. These results suggest that most individuals with well-controlled medical conditions can withstand acceleration forces of launch and re-entry profiles of current commercial spaceflight vehicles.

  5. Flexible arms provide constant force for pressure switch calibration

    NASA Technical Reports Server (NTRS)

    Cain, D. E.; Kunz, R. W.

    1966-01-01

    In-place calibration of a pressure switch is provided by a system of radially oriented flexing arms which, when rotated at a known velocity, convert the centrifugal force of the arms to a linear force along the shaft. The linear force, when applied to a pressure switch diaphragm, can then be calculated.

  6. Effect of centrifugal force on natural frequency of lateral vibration of rotating shafts

    NASA Astrophysics Data System (ADS)

    Behzad, M.; Bastami, A. R.

    2004-07-01

    This paper investigates the effect of shaft rotation on its natural frequency. Apart from gyroscopic effect, the axial force originated from centrifugal force and the Poisson effect results in change of shaft natural frequency. D'Alembert principle for shaft in cylindrical co-ordinate system, along with the stress-strain relation, gives the non-homogenous linear differential equation, which can be used to calculate axial stress in the shaft. Numerical results of this study show that axial stress produced by shaft rotation has a major effect on the natural frequency of long high-speed shafts, while shaft diameter has no influence on the results. In addition, change in lateral natural frequency due to gyroscopic effect is compared with the results of this study.

  7. Process for slip casting textured tubular structures

    DOEpatents

    Steinlage, Greg A.; Trumble, Kevin P.; Bowman, Keith J.

    2002-01-01

    A process for centrifugal slip casting a textured hollow tube. A slip made up of a carrier fluid and a suspended powder is introduced into a porous mold which is rotated at a speed sufficient to create a centrifugal force that forces the slip radially outward toward the inner surface of the mold. The suspended powder, which is formed of particles having large dimensional aspect ratios such as particles of superconductive BSCCO, settles in a textured fashion radially outward toward the mold surface. The carrier fluid of the slip passes by capillary action radially outward around the settled particles and into the absorbent mold. A layer of mold release material is preferably centrifugally slip cast to cover the mold inner surface prior to the introduction of the BSCCO slip, and the mold release layer facilitates removal of the BSCCO greenbody from the mold without fracturing.

  8. Percoll gradient-centrifuged capacitated mouse sperm have increased fertilizing ability and higher contents of sulfogalactosylglycerolipid and docosahexaenoic acid-containing phosphatidylcholine compared to washed capacitated mouse sperm.

    PubMed

    Furimsky, Anna; Vuong, Ngoc; Xu, Hongbin; Kumarathasan, Premkumari; Xu, Min; Weerachatyanukul, Wattana; Bou Khalil, Maroun; Kates, Morris; Tanphaichitr, Nongnuj

    2005-03-01

    Although Percoll gradient centrifugation has been used routinely to prepare motile human sperm, its use in preparing motile mouse sperm has been limited. Here, we showed that Percoll gradient-centrifuged (PGC) capacitated mouse sperm had markedly higher fertilizing ability (sperm-zona pellucida [ZP] binding and in vitro fertilization) than washed capacitated mouse sperm. We also showed that the lipid profiles of PGC capacitated sperm and washed capacitated sperm differed significantly. The PGC sperm had much lower contents of cholesterol and phospholipids. This resulted in relative enrichment of male germ cell-specific sulfogalactosylglycerolipid (SGG), a ZP-binding ligand, in PGC capacitated sperm, and this would explain, in part, their increased ZP-binding ability compared with that of washed capacitated sperm. Analyses of phospholipid fatty acyl chains revealed that PGC capacitated sperm were enriched in phosphatidylcholine (PC) molecular species containing highly unsaturated fatty acids (HUFAs), with docosahexaenoic acid (DHA; C22: 6n-3) being the predominant HUFA (42% of total hydrocarbon chains of PC). In contrast, the level of PC-HUFAs comprising arachidonic acid (20:4n-6), docosapentaenoic acid (C22:5n-6), and DHA in washed capacitated sperm was only 27%. Having the highest unsaturation degree among all HUFAs in PC, DHA would enhance membrane fluidity to the uppermost. Therefore, membranes of PGC capacitated sperm would undergo fertilization-related fusion events at higher rates than washed capacitated sperm. These results suggested that PGC mouse sperm should be used in fertilization experiments and that SGG and DHA should be considered to be important biomarkers for sperm fertilizing ability.

  9. Arched-outer-race ball-bearing analysis considering centrifugal forces

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.; Anderson, W. J.

    1972-01-01

    A first-order thrust load analysis that considers centrifugal forces but which neglects gyroscopics, elastohydrodynamics, and thermal effects was performed. The analysis was applied to a 150-mm-bore angular-contact ball bearing. Fatigue life, contact loads, and contact angles are shown for conventional and arched bearings. The results indicate that an arched bearing is highly desirable for high-speed applications. In particular, at an applied load of 4448 n (1000 lb) and a DN value of 3 million (20,000 rpm) the arched bearing shows an improvement in life of 306 percent over that of a conventional bearing.

  10. Autobalancing and FDIR for a space-based centrifuge prototype

    NASA Technical Reports Server (NTRS)

    Wilson, Edward; Mah, Robert W.

    2005-01-01

    This report summarizes centrifuge-related work performed at the Smart Systems Research Laboratory at NASA Ames Research Center's Computational Sciences Division from 1995 through 2003. The goal is to develop an automated system that will sense an imbalance (both static and dynamic3) in a centrifuge and issue control commands to drive counterweights to eliminate the effects of the imbalance. This autobalancing development began when the ISS centrifuge design was not yet finalized, and was designed to work with the SSRL Centrifuge laboratory prototype, constructed in 1993-1995. Significant differences between that prototype and the current International Space Station (ISS) Centrifuge design are that: the spin axis for the SSRL Centrifuge prototype can translate freely in x and y, but not wobble, whereas the ISS centrifuge spin axis has 3 translational and two rotational degrees of freedom, supported by a vibration 34. The imbalance sensors are strained gauges both in the rotor and the stator, measuring the imbalance forces, whereas the ISS centrifuge uses eddy current displacement sensors to measure the displacements resulting from imbalance. High fidelity autobalancing and FDIR systems (for both counterweights and strain gauges) are developed and tested in MATLAB simulation, for the SSRL Centrifuge configuration. Hardware implementation of the autobalancing technology was begun in 1996, but was terminated due to lack of funding. The project lay dormant until 2001-2002 when the FDIR capability was added.

  11. Magnetic-activated cell sorting before density gradient centrifugation improves recovery of high-quality spermatozoa.

    PubMed

    Berteli, T S; Da Broi, M G; Martins, W P; Ferriani, R A; Navarro, P A

    2017-07-01

    Recent studies have evaluated the use of magnetic-activated cell sorting (MACS) to reduce apoptotic spermatozoa and improve sperm quality. However, the efficiency of using MACS alone, before or after sperm processing by density gradient centrifugation (DGC) has not yet been established. The purpose of this study is to determine the optimal protocol of MACS in assisted reproduction techniques (ART). Thus, we compared sperm quality obtained by DGC alone (DGC), DGC followed by MACS (DGC-MACS), MACS followed by DGC (MACS-DGC), and MACS alone (MACS), and found that the combined methods (MACS-DGC and DGC-MACS) led to retrieval of less spermatozoa with fragmented DNA compared to the single protocols. However, MACS-DGC protocol led to a significantly higher percentage of spermatozoa with progressive motility and normal morphology than DGC-MACS protocol. These findings suggest the potential clinical value of using MACS-DGC to improve sperm quality in seminal preparation for ART. © 2017 American Society of Andrology and European Academy of Andrology.

  12. Purification of Torpedo californica post-synaptic membranes and fractionation of their constituent proteins.

    PubMed Central

    Elliott, J; Blanchard, S G; Wu, W; Miller, J; Strader, C D; Hartig, P; Moore, H P; Racs, J; Raftery, M A

    1980-01-01

    A rapid methof for preparation of membrane fractions highly enriched in nicotinic acetylcholine receptor from Torpedo californica electroplax is described. The major step in this purification involves sucrose-density-gradient centrifugation in a reorienting rotor. Further purification of these membranes can be achieved by selective extraction of proteins by use of alkaline pH or by treatment with solutions of lithium di-idosalicylate. The alkali-treated membranes retain functional characteristics of the untreated membranes and in addition contain essentially only the four polypeptides (mol.wts. 40000, 50000, 60000 and 65000) characteristic of the receptor purified by affinity chromatography. Dissolution of the purified membranes or of the alkali-treated purified membranes in sodium cholate solution followed by sucrose-density-gradient centrifugation in the same detergent solution yields solubilized receptor preparations comparable with the most highly purified protein obtained by affinity-chromatographic procedures. Images Fig. 1. Fig. 2. Fig. 3. Fig. 5. Fig. 7. PLATE 1 PMID:7387629

  13. A simple method to obtain low density marrow cells for human marrow transplantation.

    PubMed

    de Witte, T; Plas, A; Vet, J; Koekman, E; Preyers, F; Wessels, J

    1987-01-01

    Removal of more than 99% of the erythrocytes and 74% of the nucleated cells from marrow grafts was achieved by density floatation separation in Percoll gradients with a density of 1.070 g/ml in eight 250-ml tubes, containing up to 3 X 10(9) nucleated cells per gradient. More than 90% of the myeloid and erythroid progenitor cells were recovered in the low density fraction. It appeared mandatory to use a centrifuge with the possibility of a gradual acceleration and deceleration. Twenty-five patients received a marrow graft from a histocompatible sibling after additional lymphocyte depletion by counterflow centrifugation, and 5 patients with T lymphoblastic malignancies received an autograft after in vitro purging with immunotoxins. All evaluable patients engrafted within normal limits, except 1 patient with an autoimmune pancytopenia who responded to steroids and 1 patient with a CMV infection. Four patients died too early for complete evaluation. The described separation method is easy, cheap and requires only 2 h for the complete processing of a marrow graft.

  14. Mechanisms of Sensorimotor Adaptation to Centrifugation

    NASA Technical Reports Server (NTRS)

    Paloski, W. H.; Wood, S. J.; Kaufman, G. D.

    1999-01-01

    We postulate that centripetal acceleration induced by centrifugation can be used as an inflight sensorimotor countermeasure to retain and/or promote appropriate crewmember responses to sustained changes in gravito-inertial force conditions. Active voluntary motion is required to promote vestibular system conditioning, and both visual and graviceptor sensory feedback are critical for evaluating internal representations of spatial orientation. The goal of our investigation is to use centrifugation to develop an analog to the conflicting visual/gravito-inertial force environment experienced during space flight, and to use voluntary head movements during centrifugation to study mechanisms of adaptation to altered gravity environments. We address the following two hypotheses: (1) Discordant canal-otolith feedback during head movements in a hypergravity tilted environment will cause a reorganization of the spatial processing required for multisensory integration and motor control, resulting in decreased postural stability upon return to normal gravity environment. (2) Adaptation to this "gravito-inertial tilt distortion" will result in a negative after-effect, and readaptation will be expressed by return of postural stability to baseline conditions. During the third year of our grant we concentrated on examining changes in balance control following 90-180 min of centrifugation at 1.4 9. We also began a control study in which we exposed subjects to 90 min of sustained roll tilt in a static (non-rotating) chair. This allowed us to examine adaptation to roll tilt without the hypergravity induced by centrifugation. To these ends, we addressed the question: Is gravity an internal calibration reference for postural control? The remainder of this report is limited to presenting preliminary findings from this study.

  15. Computing sextic centrifugal distortion constants by DFT: A benchmark analysis on halogenated compounds

    NASA Astrophysics Data System (ADS)

    Pietropolli Charmet, Andrea; Stoppa, Paolo; Tasinato, Nicola; Giorgianni, Santi

    2017-05-01

    This work presents a benchmark study on the calculation of the sextic centrifugal distortion constants employing cubic force fields computed by means of density functional theory (DFT). For a set of semi-rigid halogenated organic compounds several functionals (B2PLYP, B3LYP, B3PW91, M06, M06-2X, O3LYP, X3LYP, ωB97XD, CAM-B3LYP, LC-ωPBE, PBE0, B97-1 and B97-D) were used for computing the sextic centrifugal distortion constants. The effects related to the size of basis sets and the performances of hybrid approaches, where the harmonic data obtained at higher level of electronic correlation are coupled with cubic force constants yielded by DFT functionals, are presented and discussed. The predicted values were compared to both the available data published in the literature and those obtained by calculations carried out at increasing level of electronic correlation: Hartree-Fock Self Consistent Field (HF-SCF), second order Møller-Plesset perturbation theory (MP2), and coupled-cluster single and double (CCSD) level of theory. Different hybrid approaches, having the cubic force field computed at DFT level of theory coupled to harmonic data computed at increasing level of electronic correlation (up to CCSD level of theory augmented by a perturbational estimate of the effects of connected triple excitations, CCSD(T)) were considered. The obtained results demonstrate that they can represent reliable and computationally affordable methods to predict sextic centrifugal terms with an accuracy almost comparable to that yielded by the more expensive anharmonic force fields fully computed at MP2 and CCSD levels of theory. In view of their reduced computational cost, these hybrid approaches pave the route to the study of more complex systems.

  16. Experimental investigation of the hydrodynamic forces on the shroud of a centrifugal pump impeller. Thesis

    NASA Technical Reports Server (NTRS)

    Zhuang, Fei

    1989-01-01

    Fluid-induced forces acting on a rotating impeller are known to cause rotor-dynamic problems in turbomachines. The forces generated by leakage flow along the front shroud surface of a centrifugal turbomachine impeller play an important role among these fluid-induced forces. The present research was aimed to gain a better understanding of these shroud forces. An experimental apparatus was designed and constructed to simulate the impeller shroud leakage flow. Hydrodynamic forces and steady and unsteady pressure distributions on the rotating shroud were measured as functions of eccentricity, width of shroud clearance, face seal clearance and shaft rotating speed. The forces measured from the dynamometer and manometers agreed well. The hydrodynamic force matrices were found skew-symmetric and statically unstable. This is qualitatively similar to the result of previous hydrodynamic volute force measurements. Nondimensionalized normal and tangential forces decrease slightly as Reynolds number increases. As the width of the shroud clearance decreases and/or the eccentricity increases, the hydrodynamic forces increase nonlinearly. There was some evidence found that increased front seal clearance could reduce the radial shroud forces and the relative magnitude of the destabilizing tangential force. Subharmonic pressure fluctuations were also observed which may adversely affect the behavior of the rotor system.

  17. Unsaturated flow in a centrifugal field: Measurement of hydraulic conductivity and testing of Darcy's Law

    USGS Publications Warehouse

    Nimmo, J.R.; Rubin, J.; Hammermeister, D.P.

    1987-01-01

    A method has been developed to establish steady state flow of water in an unsaturated soil sample spinning in a centrifuge. Theoretical analysis predicts moisture conditions in the sample that depend strongly on soil type and certain operating parameters. For Oakley sand, measurements of flux, water content, and matric potential during and after centrifugation verify that steady state flow can be achieved. Experiments have confirmed the theoretical prediction of a nearly uniform moisture distribution for this medium and have demonstrated that the flow can be effectively one-dimensional. The method was used for steady state measurements of hydraulic conductivity K for relatively dry soil, giving values as low as 7.6 × 10−11 m/s with data obtained in a few hours. Darcy's law was tested by measuring K for different centrifugal driving forces but with the same water content. For the sand at a bulk density of 1.82 Mg/m3 and 27% saturation, results were consistent with Darcy's law for K equal to 5.22 × 10−10 m/s and forces ranging from 216 to 1650 times normal gravity.

  18. Centrifuge in Free Fall: Combustion at Partial Gravity

    NASA Technical Reports Server (NTRS)

    Ferkul, Paul

    2017-01-01

    A centrifuge apparatus is developed to study the effect of variable acceleration levels in a drop tower environment. It consists of a large rotating chamber, within which the experiment is conducted. NASA Glenn Research Center 5.18-second Zero-Gravity Facility drop tests were successfully conducted at rotation rates up to 1 RPS with no measurable effect on the overall Zero-Gravity drop bus. Arbitrary simulated gravity levels from zero to 1-g (at a radius of rotation 30 cm) were produced. A simple combustion experiment was used to exercise the capabilities of the centrifuge. A total of 23 drops burning a simulated candle with heptane and ethanol fuel were performed. The effect of gravity level (rotation rate) and Coriolis force on the flames was observed. Flames became longer, narrower, and brighter as gravity increased. The Coriolis force tended to tilt the flames to one side, as expected, especially as the rotation rate was increased. The Zero-Gravity Centrifuge can be a useful tool for other researchers interested in the effects of arbitrary partial gravity on experiments, especially as NASA embarks on future missions which may be conducted in non-Earth gravity.

  19. Numerical analysis of flow in ultra micro centrifugal compressor -influence of meridional configuration

    NASA Astrophysics Data System (ADS)

    Kaneko, Masanao; Tsujita, Hoshio; Hirano, Toshiyuki

    2013-04-01

    A single stage ultra micro centrifugal compressor constituting ultra micro gas turbine is required to operate at high rotational speed in order to achieve the pressure ratio which establishes the gas turbine cycle. As a consequence, the aerodynamic losses can be increased by the interaction of a shock wave with the boundary layer on the blade surface. Moreover, the centrifugal force which exceeds the allowable stress of the impeller material can act on the root of blades. On the other hand, the restrictions of processing technology for the downsizing of impeller not only relatively enlarge the size of tip clearance but also make it difficult to shape the impeller with the three-dimensional blade. Therefore, it is important to establish the design technology for the impeller with the two-dimensional blade which possesses the sufficient aerodynamic performance and enough strength to bear the centrifugal force caused by the high rotational speed. In this study, the flow in two types of impeller with the two-dimensional blade which have different meridional configuration was analyzed numerically. The computed results clarified the influence of the meridional configuration on the loss generations in the impeller passage.

  20. How well can an amoeba climb?

    PubMed Central

    Fukui, Yoshio; Uyeda, Taro Q. P.; Kitayama, Chikako; Inoué, Shinya

    2000-01-01

    We report here our efforts to measure the crawling force generated by cells undergoing amoeboid locomotion. In a centrifuge microscope, acceleration was increased until amoebae of Dictyostelium discoideum were “stalled” or no longer able to “climb up.” The “apparent weight” of the amoebae at stalling rpm in myosin mutants depended on the presence of myosin II (but not myosins IA and IB) and paralleled the cortical strength of the cells. Surprisingly, however, the cell stalled not only in low-density media as expected but also in media with densities greater than the cell density where the buoyant force should push the amoeba upward. We find that the leading pseudopod is bent under centrifugal force in all stalled amoebae, suggesting that this pseudopod is very dense indeed. This finding also suggests that directional cell locomotion against resistive forces requires a turgid forward-pointing pseudopod, most likely sustained by cortical actomyosin II. PMID:10963666

  1. Centrifuges in gravitational physiology research

    NASA Technical Reports Server (NTRS)

    Ballard, Rodney W.; Davies, Phil; Fuller, Charles A.

    1993-01-01

    Data from space flight and ground based experiments have clearly demonstrated the importance of Earth gravity for normal physiological function in man and animals. Gravitational Physiology is concerned with the role and influence of gravity on physiological systems. Research in this field examines how we perceive and respond to gravity and the mechanisms underlying these responses. Inherent in our search for answers to these questions is the ability to alter gravity, which is not physically possible without leaving Earth. However, useful experimental paradigms have been to modify the perceived force of gravity by changing either the orientation of subjects to the gravity vector (i.e., postural changes) or by applying inertial forces to augment the magnitude of the gravity vector. The later technique has commonly been used by applying centripetal force via centrifugation.

  2. Assessing geotechnical centrifuge modelling in addressing variably saturated flow in soil and fractured rock.

    PubMed

    Jones, Brendon R; Brouwers, Luke B; Van Tonder, Warren D; Dippenaar, Matthys A

    2017-05-01

    The vadose zone typically comprises soil underlain by fractured rock. Often, surface water and groundwater parameters are readily available, but variably saturated flow through soil and rock are oversimplified or estimated as input for hydrological models. In this paper, a series of geotechnical centrifuge experiments are conducted to contribute to the knowledge gaps in: (i) variably saturated flow and dispersion in soil and (ii) variably saturated flow in discrete vertical and horizontal fractures. Findings from the research show that the hydraulic gradient, and not the hydraulic conductivity, is scaled for seepage flow in the geotechnical centrifuge. Furthermore, geotechnical centrifuge modelling has been proven as a viable experimental tool for the modelling of hydrodynamic dispersion as well as the replication of similar flow mechanisms for unsaturated fracture flow, as previously observed in literature. Despite the imminent challenges of modelling variable saturation in the vadose zone, the geotechnical centrifuge offers a powerful experimental tool to physically model and observe variably saturated flow. This can be used to give valuable insight into mechanisms associated with solid-fluid interaction problems under these conditions. Findings from future research can be used to validate current numerical modelling techniques and address the subsequent influence on aquifer recharge and vulnerability, contaminant transport, waste disposal, dam construction, slope stability and seepage into subsurface excavations.

  3. Centrifugation causes adaptation of microfilaments: studies on the transport of statoliths in gravity sensing Chara rhizoids.

    PubMed

    Braun, M; Sievers, A

    1993-01-01

    The actin cytoskeleton is involved in the positioning of statoliths in tip growing Chara rhizoids. The balance between the acropetally acting gravity force and the basipetally acting net outcome of cytoskeletal force results in the dynamically stable position of the statoliths 10-30 micrometers above the cell tip. A change of the direction and/or the amount of one of these forces in a vertically growing rhizoid results in a dislocation of statoliths. Centrifugation was used as a tool to study the characteristics of the interaction between statoliths and microfilaments (MFs). Acropetal and basipetal accelerations up to 6.5 g were applied with the newly constructed slow-rotating-centrifuge-microscope (NIZEMI). Higher accelerations were applied by means of a conventional centrifuge, namely acropetally 10-200 g and basipetally 10-70 g. During acropetal accelerations (1.4-6g), statoliths were displaced to a new stable position nearer to the cell vertex (12-6.5 micrometers distance to the apical cell wall, respectively), but they did not sediment on the apical cell wall. The original position of the statoliths was reestablished within 30 s after centrifugation. Sedimentation of statoliths and reduction of the growth rates of the rhizoids were observed during acropetal accelerations higher than 50 g. When not only the amount but also the direction of the acceleration were changed in comparison to the natural condition, i.e., during basipetal accelerations (1.0-6.5 g), statoliths were displaced into the subapical zone (up to 90 micrometers distance to the apical cell wall); after 15-20 min the retransport of statoliths to the apex against the direction of acceleration started. Finally, the natural position in the tip was reestablished against the direction of continuous centrifugation. Retransport was observed during accelerations up to 70 g. Under the 1 g condition that followed the retransported statoliths showed an up to 5-fold increase in sedimentation time onto the lateral cell wall when placed horizontally. During basipetal centrifugations > or = 70 g all statoliths entered the basal vacuolar part of the rhizoid where they were cotransported in the streaming cytoplasm. It is concluded that the MF system is able to adapt to higher mass accelerations and that the MF system of the polarly growing rhizoid is polarly organized.

  4. Serum of Blood Separation by Means of Dynamic Electrochromatography in a Centrifugal and Electromagnetic Gradient.

    PubMed

    Jan Dyszkiewicz, Andrzej

    2014-01-01

    The paper presents the dynamic association of several gradients of separation with electrophoresis and the laboratory implementation of a prototype device for dynamic electrochromatography in a centrifugal and electromagnetic gradient (DECGOE), based on patent PL171643. The object of the study was to compare the separation capacity and repeatability of the location of edge parameters (xx(1), yy(1), d) of the contours of a proteinogram fraction for conventional electrophoresis (EF), radial SR-DECGOE separation and three variants of radial-transverse SR-SPM, SR-SPE, SRSPRRM distribution as well as the reproducibility of the following prototype parameters: PV(1), PV(2), PV(3)[V] potentials, PV(3)[F] frequency, ω(1) and ω(2) rotational speed, MC mixer chamber buffer [pH] and volume[ml], and B [T] magnetic induction. Human blood serum was used in the study, 50 samples for each separation type. The highest rate of fraction formation was registered for the SR-SPRRM (8,07/s) variant. The percentage values of standard deviations for the edge parameters of proteinograms were the lowest for conventional electrophoresis (EF), slightly higher for radial distribution SR, while among the radial-transverse separations, the highest accuracy was obtained for the SR-SPRRM variant.

  5. Use of magnetic compression to support turbine engine rotors

    NASA Technical Reports Server (NTRS)

    Pomfret, Chris J.

    1994-01-01

    Ever since the advent of gas turbine engines, their rotating disks have been designed with sufficient size and weight to withstand the centrifugal forces generated when the engine is operating. Unfortunately, this requirement has always been a life and performance limiting feature of gas turbine engines and, as manufacturers strive to meet operator demands for more performance without increasing weight, the need for innovative technology has become more important. This has prompted engineers to consider a fundamental and radical breakaway from the traditional design of turbine and compressor disks which have been in use since the first jet engine was flown 50 years ago. Magnetic compression aims to counteract, by direct opposition rather than restraint, the centrifugal forces generated within the engine. A magnetic coupling is created between a rotating disk and a stationary superconducting coil to create a massive inwardly-directed magnetic force. With the centrifugal forces opposed by an equal and opposite magnetic force, the large heavy disks could be dispensed with and replaced with a torque tube to hold the blades. The proof of this concept has been demonstrated and the thermal management of such a system studied in detail; this aspect, especially in the hot end of a gas turbine engine, remains a stiff but not impossible challenge. The potential payoffs in both military and commercial aviation and in the power generation industry are sufficient to warrant further serious studies for its application and optimization.

  6. Pulmonary blood flow redistribution by increased gravitational force

    NASA Technical Reports Server (NTRS)

    Hlastala, M. P.; Chornuk, M. A.; Self, D. A.; Kallas, H. J.; Burns, J. W.; Bernard, S.; Polissar, N. L.; Glenny, R. W.

    1998-01-01

    This study was undertaken to assess the influence of gravity on the distribution of pulmonary blood flow (PBF) using increased inertial force as a perturbation. PBF was studied in unanesthetized swine exposed to -Gx (dorsal-to-ventral direction, prone position), where G is the magnitude of the force of gravity at the surface of the Earth, on the Armstrong Laboratory Centrifuge at Brooks Air Force Base. PBF was measured using 15-micron fluorescent microspheres, a method with markedly enhanced spatial resolution. Each animal was exposed randomly to -1, -2, and -3 Gx. Pulmonary vascular pressures, cardiac output, heart rate, arterial blood gases, and PBF distribution were measured at each G level. Heterogeneity of PBF distribution as measured by the coefficient of variation of PBF distribution increased from 0.38 +/- 0.05 to 0.55 +/- 0.11 to 0.72 +/- 0.16 at -1, -2, and -3 Gx, respectively. At -1 Gx, PBF was greatest in the ventral and cranial and lowest in the dorsal and caudal regions of the lung. With increased -Gx, this gradient was augmented in both directions. Extrapolation of these values to 0 G predicts a slight dorsal (nondependent) region dominance of PBF and a coefficient of variation of 0.22 in microgravity. Analysis of variance revealed that a fixed component (vascular structure) accounted for 81% and nonstructure components (including gravity) accounted for the remaining 19% of the PBF variance across the entire experiment (all 3 gravitational levels). The results are inconsistent with the predictions of the zone model.

  7. An analysis on the magnetic fluid seal capacity

    NASA Astrophysics Data System (ADS)

    Meng, Zhao; Jibin, Zou; Jianhui, Hu

    2006-08-01

    The capacity of the magnetic fluid seal depends on the magnetic field and the saturation magnetization of the magnetic fluid. There are many factors that influence the magnetic field and the seal capacity of the magnetic fluid seal, such as the sealing gap, the shaft eccentricity, the shaft diameter, and the centrifugal force. In this paper, these factors are analyzed by numerical computations. When the material and structure are the same, the magnetic fluid seal capacity will reduce with the increasing of the sealing gap. When the shaft diameter is large the gravity should be considered. The centrifugal force has influence on the magnetic fluid seal capacity.

  8. Understanding the organization of the amphibian egg cytoplasm - Gravitational force as a probe

    NASA Technical Reports Server (NTRS)

    Neff, Anton W.; Malacinski, George M.; Yokota, Hiroki; Wakahara, Masami

    1992-01-01

    A combination of hypergravity (centrifugation) and hypogravity (clinostat) studies have been carried out on amphibian (frog, Xenopus) eggs. The results reveal that the twinning caused by centrifugation exhibits substantial spawning to spawning variation. That variation can be attributed to the apparent viscosity of the egg's internal cytoplasm. Simulated hypogravity results in a relocation of the egg's third (horizontal) cleavage furrow, toward the equator. Substantial egg-to-egg variation is also observed in this 'cleavage effect'. For interpreting spaceflight data and for using G-forces as probes for understanding the egg's architecture the egg variation documented herein should be considered.

  9. Behavior of turbulent boundary layers on curved convex walls

    NASA Technical Reports Server (NTRS)

    Schmidbauer, Hans

    1936-01-01

    The system of linear differential equations which indicated the approach of separation and the so-called "boundary-layer thickness" by Gruschwitz is extended in this report to include the case where the friction layer is subject to centrifugal forces. Evaluation of the data yields a strong functional dependence of the momentum change and wall drag on the boundary-layer thickness radius of curvature ratio for the wall. It is further shown that the transition from laminar to turbulent flow occurs at somewhat higher Reynolds Numbers at the convex wall than at the flat plate, due to the stabilizing effect of the centrifugal forces.

  10. Cantilever Beam Natural Frequencies in Centrifugal Inertia Field

    NASA Astrophysics Data System (ADS)

    Jivkov, V. S.; Zahariev, E. V.

    2018-03-01

    In the advanced mechanical science the well known fact is that the gravity influences on the natural frequencies and modes even for the vertical structures and pillars. But, the condition that should be fulfilled in order for the gravity to be taken into account is connected with the ration between the gravity value and the geometrical cross section inertia. The gravity is related to the earth acceleration but for moving structures there exist many other acceleration exaggerated forces and such are forces caused by the centrifugal accelerations. Large rotating structures, as wind power generators, chopper wings, large antennas and radars, unfolding space structures and many others are such examples. It is expected, that acceleration based forces influence on the structure modal and frequency properties, which is a subject of the present investigations. In the paper, rotating beams are subject to investigations and modal and frequency analysis is carried out. Analytical dependences for the natural resonances are derived and their dependences on the angular velocity and centrifugal accelerations are derived. Several examples of large rotating beams with different orientations of the rotating shaft are presented. Numerical experiments are conducted. Time histories of the beam tip deflections, that depict the beam oscillations are presented.

  11. Isolation of exosomes by differential centrifugation: Theoretical analysis of a commonly used protocol

    NASA Astrophysics Data System (ADS)

    Livshts, Mikhail A.; Khomyakova, Elena; Evtushenko, Evgeniy G.; Lazarev, Vassili N.; Kulemin, Nikolay A.; Semina, Svetlana E.; Generozov, Edward V.; Govorun, Vadim M.

    2015-11-01

    Exosomes, small (40-100 nm) extracellular membranous vesicles, attract enormous research interest because they are carriers of disease markers and a prospective delivery system for therapeutic agents. Differential centrifugation, the prevalent method of exosome isolation, frequently produces dissimilar and improper results because of the faulty practice of using a common centrifugation protocol with different rotors. Moreover, as recommended by suppliers, adjusting the centrifugation duration according to rotor K-factors does not work for “fixed-angle” rotors. For both types of rotors - “swinging bucket” and “fixed-angle” - we express the theoretically expected proportion of pelleted vesicles of a given size and the “cut-off” size of completely sedimented vesicles as dependent on the centrifugation force and duration and the sedimentation path-lengths. The proper centrifugation conditions can be selected using relatively simple theoretical estimates of the “cut-off” sizes of vesicles. Experimental verification on exosomes isolated from HT29 cell culture supernatant confirmed the main theoretical statements. Measured by the nanoparticle tracking analysis (NTA) technique, the concentration and size distribution of the vesicles after centrifugation agree with those theoretically expected. To simplify this “cut-off”-size-based adjustment of centrifugation protocol for any rotor, we developed a web-calculator.

  12. IDENTIFICATION AND CHARACTERIZATION OF INFECTIOUS AND NON-INFECTIOUS SUB-POPULATIONS OF ENCEPHALITIZOON INTESTINALIS SPORES PURIFIED FROM IN VITRO CELL CULTURE

    EPA Science Inventory

    Background: Encephalitizoon intestinalis spores were propagated in rabbit kidney (RK-13) cells and were purified using density gradient (Percoll [registered trademark]) centrifugation. Purified spores were enumeraged and aliquotted using flow cytometry with cell sorting for use...

  13. How-to-Do-It. An Exercise in Gene Mapping.

    ERIC Educational Resources Information Center

    Seidel-Rogol, Bonnie L.

    1990-01-01

    Described is a laboratory exercise designed to introduce students to the theory and practice of gene mapping including RNA extraction, sucrose density gradient centrifugation, labelling of nucleic acids in vitro, DNA extraction, digestion of DNA with restriction enzymes, and the southern hybridization analysis. Procedures and sample results are…

  14. Inertial particle focusing in serpentine channels on a centrifugal platform

    NASA Astrophysics Data System (ADS)

    Shamloo, Amir; Mashhadian, Ali

    2018-01-01

    Inertial particle focusing as a powerful passive method is widely used in diagnostic test devices. It is common to use a curved channel in this approach to achieve particle focusing through balancing of the secondary flow drag force and the inertial lift force. Here, we present a focusing device on a disk based on the interaction of secondary flow drag force, inertial lift force, and centrifugal forces to focus particles. By choosing a channel whose cross section has a low aspect ratio, the mixing effect of the secondary flow becomes negligible. To calculate inertial lift force, which is exerted on the particle from the fluid, the interaction between the fluid and particle is investigated accurately through implementation of 3D Direct Numerical Solution (DNS) method. The particle focusing in three serpentine channels with different corner angles of 75°, 85°, and 90° is investigated for three polystyrene particles with diameters of 8 μm, 9.9 μm, and 13 μm. To show the simulation reliability, the results obtained from the simulations of two examples, namely, particle focusing and centrifugal platform, are verified against experimental counterparts. The effects of angular velocity of disk on the fluid velocity and on the focusing parameters are studied. Fluid velocity in a channel with corner angle of 75° is greater than two other channels. Furthermore, the particle equilibrium positions at the cross section of channel are obtained at the outlet. There are two equilibrium positions located at the centers of the long walls. Finally, the effect of particle density on the focusing length is investigated. A particle with a higher density and larger diameter is focused in a shorter length of the channel compared to its counterpart with a lower density and shorter diameter. The channel with a corner angle of 90° has better focusing efficiency compared to other channels. This design focuses particles without using any pump or sheath flow. Inertial particle focusing on centrifugal platform, which rarely has been studied, can be used for a wide range of diagnostic lab-on-a-disk device.

  15. Influence of G-forces on venous and nervous systems

    NASA Technical Reports Server (NTRS)

    Dyskin, Y. A.; Prives-Bardina, R. A.; Tikhonova, L. P.

    1975-01-01

    Cats and rabbits were subjected to rotation in the centrifuge. Controls were maintained to determine the individual tolerance to g-forces. Thickening of the vascular wall was found to occur due to the g-forces' effect, as well as other vascular changes. Nervous changes included edema and chromatolysis of the nerve cells.

  16. Movement of the Melt Metal Layer under Conditions Typical of Transient Events in ITER

    NASA Astrophysics Data System (ADS)

    Poznyak, I. M.; Safronov, V. M.; Zybenko, V. Yu.

    2017-12-01

    During the operation of ITER, protective coatings of the divertor and the first wall will be exposed to significant plasma heat loads which may cause a huge erosion. One of the major failure mechanisms of metallic armor is diminution of their thickness due to the melt layer displacement. New experimental data are required in order to develop and validate physical models of the melt layer movement. The paper presents the experiments where metal targets were irradiated by a plasma stream at the quasi-stationary high-current plasma accelerator QSPA-T. The obtained data allow one to determine the velocity and acceleration of the melt layer at various distances from the plasma stream axis. The force causing the radial movement of the melt layer is shown to create an acceleration whose order of magnitude is 1000g. The pressure gradient is not responsible for creating this large acceleration. To investigate the melt layer movement under a known force, the experiment with a rotating target was carried out. The influence of centrifugal and Coriolis forces led to appearance of curved elongated waves on the surface. The surface profile changed: there is no hill in the central part of the erosion crater in contrast to the stationary target. The experimental data clarify the trends in the melt motion that are required for development of theoretical models.

  17. Different elution modes and field programming in gravitational field-flow fractionation. III. Field programming by flow-rate gradient generated by a programmable pump.

    PubMed

    Plocková, J; Chmelík, J

    2001-05-25

    Gravitational field-flow fractionation (GFFF) utilizes the Earth's gravitational field as an external force that causes the settlement of particles towards the channel accumulation wall. Hydrodynamic lift forces oppose this action by elevating particles away from the channel accumulation wall. These two counteracting forces enable modulation of the resulting force field acting on particles in GFFF. In this work, force-field programming based on modulating the magnitude of hydrodynamic lift forces was implemented via changes of flow-rate, which was accomplished by a programmable pump. Several flow-rate gradients (step gradients, linear gradients, parabolic, and combined gradients) were tested and evaluated as tools for optimization of the separation of a silica gel particle mixture. The influence of increasing amount of sample injected on the peak resolution under flow-rate gradient conditions was also investigated. This is the first time that flow-rate gradients have been implemented for programming of the resulting force field acting on particles in GFFF.

  18. Sorting process of nanoparticles and applications of same

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tyler, Timothy P.; Henry, Anne-Isabelle; Van Duyne, Richard P.

    In one aspect of the present invention, a method for sorting nanoparticles includes preparing a high-viscosity density gradient medium filled in a container, dispersing nanoparticles into an aqueous solution to form a suspension of the nanoparticles, each nanoparticle having one or more cores and a shell encapsulating the one or more cores, layering the suspension of the nanoparticles on the top of the high-viscosity density gradient medium in the container, and centrifugating the layered suspension of the nanoparticles on the top of the high-viscosity density gradient medium in the container at a predetermined speed for a predetermined period of timemore » to form a gradient of fractions of the nanoparticles along the container, where each fraction comprises nanoparticles in a respective one of aggregation states of the nanoparticles.« less

  19. Social network influences on smoking, drinking and drug use in secondary school: centrifugal and centripetal forces.

    PubMed

    Fletcher, Adam; Bonell, Chris

    2013-06-01

    We explore how school experiences and social networks structure young people's substance use in different institutional contexts. The concepts of 'selection' and 'influence' are situated within the context of bounded agency, counter-school cultures and Bourdieusian notions of capital. We employed individual and group interviews, network-mapping, and observations at two contrasting English secondary schools. Both schools were characterised by extended social network structures that appeared to influence patterns of substance use, although the mechanisms via which this occurred varied according to school context. At Grange House school (suburban context) a minority of students from disadvantaged families were alienated by the attainment-focused regime, marginalised by a strong peer-led centrifugal force pushing them outwards, and substance use was an alternative source of bonding and identity for these students. In contrast, at North Street a centripetal force operated whereby the majority of students were pulled towards highly-visible, normative markers of 'safe', 'road culture', such as cannabis use and gang-involvement, as they attempted to fit in and survive in an inner-city school environment. We conclude that health inequalities may be reproduced through these distinctive centrifugal and centripetal forces in different institutional contexts, and this should be the focus of quantitative examination in the UK and elsewhere. © 2013 The Authors. Sociology of Health & Illness © 2013 Foundation for the Sociology of Health & Illness/John Wiley & Sons Ltd.

  20. DEM simulation of granular flows in a centrifugal acceleration field

    NASA Astrophysics Data System (ADS)

    Cabrera, Miguel Angel; Peng, Chong; Wu, Wei

    2017-04-01

    The main purpose of mass-flow experimental models is abstracting distinctive features of natural granular flows, and allow its systematic study in the laboratory. In this process, particle size, space, time, and stress scales must be considered for the proper representation of specific phenomena [5]. One of the most challenging tasks in small scale models, is matching the range of stresses and strains among the particle and fluid media observed in a field event. Centrifuge modelling offers an alternative to upscale all gravity-driven processes, and it has been recently employed in the simulation of granular flows [1, 2, 3, 6, 7]. Centrifuge scaling principles are presented in Ref. [4], collecting a wide spectrum of static and dynamic models. However, for the case of kinematic processes, the non-uniformity of the centrifugal acceleration field plays a major role (i.e., Coriolis and inertial effects). In this work, we discuss a general formulation for the centrifugal acceleration field, implemented in a discrete element model framework (DEM), and validated with centrifuge experimental results. Conventional DEM simulations relate the volumetric forces as a function of the gravitational force Gp = mpg. However, in the local coordinate system of a rotating centrifuge model, the cylindrical centrifugal acceleration field needs to be included. In this rotating system, the centrifugal acceleration of a particle depends on the rotating speed of the centrifuge, as well as the position and speed of the particle in the rotating model. Therefore, we obtain the formulation of centrifugal acceleration field by coordinate transformation. The numerical model is validated with a series of centrifuge experiments of monodispersed glass beads, flowing down an inclined plane at different acceleration levels and slope angles. Further discussion leads to the numerical parameterization necessary for simulating equivalent granular flows under an augmented acceleration field. The premise of this validation is abstracting the role of the governing acceleration on the granular flow dynamics and extend it to a wider range of accelerations and slope angles. Based on this results we aim to validate the centrifuge scaling principle of flow velocity and flow height, and discuss the viability of centrifuge modelling of mass flows in a wider range of configurations. References T. Arndt, A. Brucks, J.M. Ottino, and R. Lueptow. Creeping granular motion under variable gravity levels. Phys. Rev. E, 74 (031307), 2006. E. Bowman, J. Laue, and S. Springman. Experimental modelling of debris flow behaviour using a geotechnical centrifuge. Canadian Geotechnical Journal, 47(7): 742 - 762, 2010. M. Cabrera. Experimental modelling of granular flows in rotating frames. PhD thesis, University of Natural Resources and Life Sciences, Vienna, February 2016 J. Garnier, C. Gaudin, S.M. Springman, P.J. Culligan, D.J. Goodings, D. Konig, B.L. Kutter, R. Phillips, M.F. Randolph, and L. Thorel. Catalogue of scaling laws and similitude questions in geotechnical centrifuge modelling. International Journal of Physical Modelling in Geotechnics, 7(3):1 - 23, 2007. R.M. Iverson. Scaling and design of landslide and debris-flow experiments. Geomorphology, 2015. J. Mathews. Investigation of granular flow using silo centrifuge models. PhD thesis, University of Natural Resources and Life Sciences, Vienna, September 2013. L. Vallejo, N. Estrada, A. Taboada, B. Caicedo, and J.A. Silva. Numerical and physical modeling of granular flow. In C.W. Ng, Y.H. Wang, and L.M. Zhang, editors, Physical Modelling in Geotechnics. Taylor & Francis, July 2006.

  1. Morphology of Arabidopsis Grown under Chronic Centrifugation and on the Clinostat 123

    PubMed Central

    Brown, Allan H.; Dahl, A. Orville; Chapman, David K.

    1976-01-01

    Morphological measurements were made on populations of Arabidopsis thaliana grown from seed for 21 days under essentially constant environmental conditions except for the influence of gravitational or centrifugal accelerations. Growth conditions were what had been proposed for experiments in an artificial satellite. Observations are reported for plants grown at normal 1-g upright or on horizontal clinostats and for plants grown on a centrifuge. Increased g-force, up to 15 times normal, was found to have significant but small effects on some morphological end points. The plants' sensitivity to the magnitude of the g-force was much less than to its vector direction. Data from centrifuge experiments (which determined the g-functions for particular characters) were extrapolated to zero-g to predict a set of morphological characteristics of a plant developing in the satellite environment. As an alternative means of predicting properties of a zero-g plant, characteristics of plants grown on horizontal clinostats were measured. The results of these two predictive methods were not in agreement. Clinostat grown plants were morphologically distinct from upright stationary controls. When plants were grown while rotating in the upright position on vertical clinostats they were similar to stationary plants also grown upright, but there were small differences some of which were statistically significant. PMID:16659483

  2. Separation of active laccases from Pleurotus sapidus culture supernatant using aqueous two-phase systems in centrifugal partition chromatography.

    PubMed

    Schwienheer, C; Prinz, A; Zeiner, T; Merz, J

    2015-10-01

    For the production of bio active compounds, e.g., active enzymes or antibodies, a conserved purification process with a minimum loss of active compounds is necessary. In centrifugal partition chromatography (CPC), the separation effect is based on the different distribution of the components to be separated between two immiscible liquid phases. Thereby, one liquid phase is kept stationary in chambers by a centrifugal field and the mobile phase is pumped through via connecting ducts. Aqueous two phase systems (ATPS) are known to provide benign conditions for biochemical products and seem to be promising when used in CPC for purification tasks. However, it is not known if active biochemical compounds can "survive" the conditions in a CPC where strong shear forces can occur due to the two-phasic flow under centrifugal forces. Therefore, this aspect has been faced within this study by the separation of active laccases from a fermentation broth of Pleurotus sapidus. After selecting a suitable ATPS and operating conditions, the activity yield was calculated and the preservation of the active enzymes could be observed. Therefore, CPC could be shown as potentially suitable for the purification of bio-active compounds. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Possible biomedical applications and limitations of a variable-force centrifuge on the lunar surface: A research tool and an enabling resource

    NASA Technical Reports Server (NTRS)

    Cowing, Keith L.

    1992-01-01

    Centrifuges will continue to serve as a valuable research tool in gaining an understanding of the biological significance of the inertial acceleration due to gravity. Space- and possibly lunar-based centrifuges will play a significant and enabling role with regard to the human component of future lunar and martian exploration, both as a means of accessing potential health and performance risks and as a means of alleviating these risks. Lunar-based centrifuges could be particularly useful as part of a program of physiologic countermeasures designed to alleviate the physical deconditioning that may result from prolonged exposure to a 1/6-g environment. Centrifuges on the lunar surface could also be used as part of a high-fidelity simulation of a trip to Mars. Other uses could include crew readaptation to 1 g, waste separation, materials processing, optical mirror production in situ on the Moon, and laboratory specimen separation.

  4. The Mechanical Strength of Si Foams in the Mushy Zone during Solidification of Al–Si Alloys

    PubMed Central

    Lim, Jeon Taik; Youn, Ji Won; Seo, Seok Yong; Kim, Ki Young; Kim, Suk Jun

    2017-01-01

    The mechanical strength of an Al-30% Si alloy in the mushy zone was estimated by using a novel centrifugation apparatus. In the apparatus, the alloy melt was partially solidified, forming a porous structure made of primary Si platelets (Si foam) while cooling. Subsequently, pressure generated by centrifugal force pushed the liquid phase out of the foam. The estimated mechanical strength of the Si foam in the temperature range 850–993 K was very low (62 kPa to 81 kPa). This is about two orders of magnitude lower than the mechanical strength at room temperature as measured by compressive tests. When the centrifugal stress was higher than the mechanical strength of the foam, the foam fractured, and the primary Si crystallites were extracted along with the Al-rich melt. Therefore, to maximize the centrifugal separation efficiency of the Al-30% Si alloy, the centrifugal stress should be in the range of 62–81 kPa. PMID:28772695

  5. Multijoint kinetic chain analysis of knee extension during the soccer instep kick.

    PubMed

    Naito, Kozo; Fukui, Yosuke; Maruyama, Takeo

    2010-04-01

    Although previous studies have shown that motion-dependent interactions between adjacent segments play an important role in producing knee extension during the soccer instep kick, detailed knowledge about the mechanisms underlying those interactions is lacking. The present study aimed to develop a 3-D dynamical model for the multijoint kinetic chain of the instep kick in order to quantify the contributions of the causal dynamical factors to the production of maximum angular velocity during knee extension. Nine collegiate soccer players volunteered to participate in the experiment and performed instep kicking movements while 3-D positional data and the ground reaction force were measured. A dynamical model was developed in the form of a linked system containing 8 segments and 18 joint rotations, and the knee extension/flexion motion was decomposed into causal factors related to muscular moment, gyroscopic moment, centrifugal force, Coriolis force, gravity, proximal endpoint linear acceleration, and external force-dependent terms. The rapid knee extension during instep kicking was found to result almost entirely from kicking leg centrifugal force, trunk rotation muscular moment, kicking leg Coriolis force, and trunk rotation gyroscopic-dependent components. Based on the finding that rapid knee extension during instep kicking stems from multiple dynamical factors, it is suggested that the multijoint kinetic chain analysis used in the present study is more useful for achieving a detailed understanding of the cause of rapid kicking leg movement than the previously used 2-D, two-segment kinetic chain model. The present results also indicated that the centrifugal effect due to the kicking hip flexion angular velocity contributed substantially to the generation of a rapid knee extension, suggesting that the adjustment between the kicking hip flexion angular velocity and the leg configuration (knee flexion angle) is more important for effective instep kicking than other joint kinematics.

  6. Do Things Weigh More or Less in the Mountains?

    ERIC Educational Resources Information Center

    Besson, Ugo

    2006-01-01

    The notion of weight can be associated with three distinct physical quantities: the force of gravity due to the Earth; the resultant of this gravitational force and the centrifugal force arising from the Earth's rotation; and the "apparent weight in air", i.e., what is measured by a scale located in the Earth's atmosphere. Starting from…

  7. The centrifugal force reversal and X-ray bursts

    NASA Astrophysics Data System (ADS)

    Abramowicz, M. A.; Kluźniak, W.; Lasota, J. P.

    2001-08-01

    Heyl (2000) made an interesting suggestion that the observed shifts in QPO frequency in type I X-ray bursts could be influenced by the same geometrical effect of strong gravity as the one that causes centrifugal force reversal discovered by Abramowicz & Lasota (1974). However, his main result contains a sign error. Here we derive the correct formula and conclude that constraints on the M(R) relation for neutron stars deduced from the rotational-modulation model of QPO frequency shifts are of no practical interest because the correct formula implies a weak condition R* > 1.3 RS, where RS is the Schwarzschild radius. We also argue against the relevance of the rotational-modulation model to the observed frequency modulations.

  8. Acoustic performance of low pressure axial fan rotors with different blade chord length and radial load distribution

    NASA Astrophysics Data System (ADS)

    Carolus, Thomas

    The paper examines the acoustic and aerodynamic performance of low-pressure axial fan rotors with a hub/tip ratio of 0.45. Six rotors were designed for the same working point by means of the well-known airfoil theory. The condition of an equilibrium between the static pressure gradient and the centrifugal forces is maintained. All rotors have unequally spaced blades to diminish tonal noise. The rotors are tested in a short cylindrical housing without guide vanes. All rotors show very similar flux-pressure difference characteristics. The peak efficiency and the noise performance is considerably influenced by the chosen blade design. The aerodynamically and acoustically optimal rotor is the one with the reduced load at the hub and increased load in the tip region under satisfied equilibrium conditions. It runs at the highest aerodynamic efficiency, and its noise spectrum is fairly smooth. The overall sound pressure level of this rotor is up to 8 dB (A) lower compared to the other rotors under consideration.

  9. Cultivation, detection, and ecophysiology of anaerobic ammonium-oxidizing bacteria.

    PubMed

    Kartal, Boran; Geerts, Wim; Jetten, Mike S M

    2011-01-01

    Anaerobic ammonium-oxidizing (anammox) bacteria oxidize ammonium with nitrite under anoxic conditions. The anammox process is currently used to remove ammonium from wastewater and contributes significantly to the loss of fixed nitrogen from the oceans. In this chapter, we focus on the ecophysiology of anammox bacteria and describe new methodologies to grow these microorganisms. Now, it is possible to enrich anammox bacteria up to 95% with a membrane bioreactor that removes forces of selection for fast settling aggregates and facilitates the growth of planktonic cells. The biomass from this system has a high anaerobic ammonium oxidation rate (50 fmol NH(4)(+) · cell(-1) day(-1)) and is suitable for many ecophysiological and molecular experiments. A high throughput Percoll density gradient centrifugation protocol may be applied on this biomass for further enrichment (>99.5%) of anammox bacteria. Furthermore, we provide an up-to-date list of commonly used primers and introduce protocols for quantification and detection of functional genes of anammox bacteria in their natural environment. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lukeman, S.; Fanestil, D.

    Although the PBS has been identified in many organs, its function and cellular location are speculative. Using rapid filtration, binding of (/sup 3/H)RO 5-4864 (*RO) (.75 nM) was assessed in four subcellular fractions (.3 mg/ml) derived from depapillated rat kidney by differential centrifugation: N (450g x 2 min), O (13,000 x 10), P (105,000 x 30), and S. The binding distribution was: N-18%, O-74%, P-6%, and S-2%. Marker enzyme analysis revealed that O was enriched in mitochondria (M), lysosomes (L), peroxisomes (P), and endoplasmic reticulum (ER), but not plasma membrane, and that N contained small amounts (10-15%) of markers formore » the above. Repeated washing of O removed ER enzymes but preserved *RO binding. O was further fractionated with centrifugation (57,000g x 4 hr) on a linear sucrose gradient (18-65%); *RO binding then comigrated with M but not P and L markers. Centrifugation of isolated M (5500 x 10 min) on another linear sucrose gradient (37-65%) gave low and high density bands, which contained 65% and 35% of *RO binding activity, resp. *RO binding in O was specific, saturable, reversible, and inhibited by diuretics. Inhibitors with the highest potency were indacrinone (K/sub d/ = 35 ..mu..M), hydrochlorothiazide (100 ..mu..M), and ethacrynic acid (325 ..mu..M). Low potency inhibitors (K/sub d/ greater than or equal to 1 mM) included amiloride, triamterene, furosemide, bumetanide, and ozolinone.« less

  11. Impact of centrifugal drifts on ion turbulent transport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belli, Emily A.; Candy, J.

    Here, the influence of sonic toroidal rotation on gyrokinetic stability and transport is studied, with important implications for heavy impurity dynamics. When centrifugal drifts and electrostatic trapping corrections are included, significant modifications to the calculated transport of heavy impurities are observed. These high-rotation corrections add to the standard Coriolis drift and toroidal rotation shear drive which are normally included in gyrokinetics. Yet, because of their complexity, centrifugal and electrostatic trapping terms (quadratic in the main ion Mach number) are not generally included in gyrokinetic codes. In this work, we explore the implications of using reduced descriptions of the rotational physics.more » For heavy impurities such as tungsten, cross terms due to the centrifugal force can dominate the rotation dynamics, and neglecting them is shown to lead to large errors in the impurity particle flux.« less

  12. Impact of centrifugal drifts on ion turbulent transport

    DOE PAGES

    Belli, Emily A.; Candy, J.

    2018-03-01

    Here, the influence of sonic toroidal rotation on gyrokinetic stability and transport is studied, with important implications for heavy impurity dynamics. When centrifugal drifts and electrostatic trapping corrections are included, significant modifications to the calculated transport of heavy impurities are observed. These high-rotation corrections add to the standard Coriolis drift and toroidal rotation shear drive which are normally included in gyrokinetics. Yet, because of their complexity, centrifugal and electrostatic trapping terms (quadratic in the main ion Mach number) are not generally included in gyrokinetic codes. In this work, we explore the implications of using reduced descriptions of the rotational physics.more » For heavy impurities such as tungsten, cross terms due to the centrifugal force can dominate the rotation dynamics, and neglecting them is shown to lead to large errors in the impurity particle flux.« less

  13. Distribution of resting spores of the Lymantria dispar pathogen Entomophaga maimaiga in soil and on bark

    Treesearch

    A. E. Hajek; L. Bauer; M. L. McManus; M. M. Wheeler

    1998-01-01

    Cadavers of late instar Lymantria dispar (gypsy moth) larvae killed by the fungal pathogen Entomophaga maimaiga predominantly contain resting spores (azygospores). These cadavers frequently remain attached to tree trunks for several weeks before they detach and fall to the ground. Density gradient centrifugation was used to...

  14. RESTRICTION FRAGMENT LENGTH POLYMORPHISM ANALYSIS OF PCR-AMPLIFIED NIFH SEQUENCES FROM WETLAND PLANT RHIZOSPHERE COMMUNITIES

    EPA Science Inventory

    We describe a method to assess the community structure of N2-fixing bacteria in the rhizosphere. Total DNA was extracted from Spartina alterniflora and Sesbania macrocarpa root zones by bead-beating and purified by CsCl-EtBr gradient centrifugation. The average DNA yield was 5.5 ...

  15. Gravity of Living Systems: May the Force Be With You

    NASA Technical Reports Server (NTRS)

    Hargens, Alan R.; Holton, Emily M. (Technical Monitor)

    1998-01-01

    Gravity, the force which shapes the architecture of organisms from single cells to dinosaurs, has been the most constant environmental factor during the evolution of species on Earth. With long-duration space flight, an understanding of how gravity affects living systems gains greater urgency in order to maintain the health and performance of crews who will explore the solar system. For example, the cardiovascular and musculoskeletal systems are normally exposed to gravitational gradients of blood pressure and weight on Earth. Such gradients increase blood pressure and tissue weight in dependent tissues of the body. Thus, from a physiologic standpoint, these systems are greatly affected by altered gravity. Exposure to actual and simulated microgravity causes blood and tissue fluid to shift from the legs to the head. Studies of humans in space have documented facial edema, space adaptation syndrome, decreased plasma volume, muscle atrophy, and loss of bone strength. Return of astronauts to Earth is accompanied by orthostatic intolerance, decreased neuromuscular coordination, and reduced exercise capacity. These factors decrease performance during descent from orbit and increase risk during emergency egress from the space craft. Models of simulated microgravity include 60 head-down tilt, immersion, and prolonged horizontal bedrest. Head-down tilt and dry immersion are the most accepted models and studies using these models of up to one year have been performed in Russia. Sensitive animal models which offer clear insights into the role of gravity on structure and function include the developing giraffe and snakes from various habitats. Finally, possible countermeasures to speed readaptation of astronauts to gravity after prolonged space flight include exercise, lower body negative pressure, and centrifugation.

  16. Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography.

    PubMed

    Ikehata, Jun-Ichi; Shinomiya, Kazufusa; Kobayashi, Koji; Ohshima, Hisashi; Kitanaka, Susumu; Ito, Yoichiro

    2004-02-06

    The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.

  17. Shock and Vibration Control of a Golf-Swing Robot at Impacting the Ball

    NASA Astrophysics Data System (ADS)

    Hoshino, Yohei; Kobayashi, Yukinori

    A golf swing robot is a kind of fast motion manipulator with a flexible link. A robot manipulator is greatly affected by Corioli's and centrifugal forces during fast motion. Nonlinearity due to these forces can have an adverse effect on the performance of feedback control. In the same way, ordinary state observers of a linear system cannot accurately estimate the states of nonlinear systems. This paper uses a state observer that considers disturbances to improve the performance of state estimation and feedback control. A mathematical model of the golf robot is derived by Hamilton's principle. A linear quadratic regulator (LQR) that considers the vibration of the club shaft is used to stop the robot during the follow-through action. The state observer that considers disturbances estimates accurate state variables when the disturbances due to Corioli's and centrifugal forces, and impact forces work on the robot. As a result, the performance of the state feedback control is improved. The study compares the results of the numerical simulations with experimental results.

  18. Colloid centrifugation of boar semen.

    PubMed

    Morrell, J M; Wallgren, M

    2011-09-01

    Colloid centrifugation of boar semen has been reported sporadically for at least the last two decades, beginning with density gradient centrifugation (DGC) and progressing more recently to single layer centrifugation (SLC). Single layer centrifugation through a species-specific colloid has been shown to be effective in selecting the best spermatozoa (spermatozoa with good motility and normal morphology) from boar sperm samples. The method is easier to use and less time-consuming than DGC and has been scaled-up to allow whole ejaculates from other species, e.g. stallions, to be processed in a practical manner. The SLC technique is described, and various scale-up versions are presented. The potential applications for SLC in boar semen preservation are as follows: to improve sperm quality in artificial insemination (AI) doses for 'problem' boars; to increase the shelf-life of normal stored sperm samples, either by processing the fresh semen before preparing AI doses or by processing the stored semen dose to extract the best spermatozoa; to remove pathogens (viruses, bacteria), thus improving biosecurity of semen doses and potentially reducing the use of antibiotics; to improve cryosurvival by removing dead and dying spermatozoa prior to cryopreservation; to select spermatozoa for in vitro fertilization. These applications are discussed and practical examples are provided. Finally, a few thoughts about the economic value of the technique to the boar semen industry are presented. © 2011 Blackwell Verlag GmbH.

  19. Simulated stand tests and centrifuge training to prevent orthostatic intolerance on Earth, moon, and Mars.

    PubMed

    Coats, Brandon W; Sharp, M Keith

    2010-03-01

    One proposed method to overcome postflight orthostatic intolerance is for astronauts to undergo inflight centrifugation. Cardiovascular responses were compared between centrifuge and gravitational conditions using a seven-compartment cardiovascular model. Vascular resistance, heart rate, and stroke volume values were adopted from literature, while compartmental volumes and compliances were derived from impedance plethysmography of subjects (n=8) riding on a centrifuge. Three different models were developed to represent the typical male subject who completed a 10-min postflight stand test ("male finisher"), "non-finishing male" and "female" (all non-finishers). A sensitivity analysis found that both cardiac output and arterial pressure were most sensitive to total blood volume. Simulated stand tests showed that female astronauts were more susceptible to orthostatic intolerance due to lower initial blood pressure and higher pressure threshold for presyncope. Rates of blood volume loss by capillary filtration were found to be equivalent in female and male non-finishers, but four times smaller in male finishers. For equivalent times to presyncope during centrifugation as those during constant gravity, lower G forces at the level of the heart were required. Centrifuge G levels to match other cardiovascular parameters varied depending on the parameter, centrifuge arm length, and the gravity level being matched.

  20. Analogue scale modelling of extensional tectonic processes using a large state-of-the-art centrifuge

    NASA Astrophysics Data System (ADS)

    Park, Heon-Joon; Lee, Changyeol

    2017-04-01

    Analogue scale modelling of extensional tectonic processes such as rifting and basin opening has been numerously conducted. Among the controlling factors, gravitational acceleration (g) on the scale models was regarded as a constant (Earth's gravity) in the most of the analogue model studies, and only a few model studies considered larger gravitational acceleration by using a centrifuge (an apparatus generating large centrifugal force by rotating the model at a high speed). Although analogue models using a centrifuge allow large scale-down and accelerated deformation that is derived by density differences such as salt diapir, the possible model size is mostly limited up to 10 cm. A state-of-the-art centrifuge installed at the KOCED Geotechnical Centrifuge Testing Center, Korea Advanced Institute of Science and Technology (KAIST) allows a large surface area of the scale-models up to 70 by 70 cm under the maximum capacity of 240 g-tons. Using the centrifuge, we will conduct analogue scale modelling of the extensional tectonic processes such as opening of the back-arc basin. Acknowledgement This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (grant number 2014R1A6A3A04056405).

  1. Feedforward compensation control of rotor imbalance for high-speed magnetically suspended centrifugal compressors using a novel adaptive notch filter

    NASA Astrophysics Data System (ADS)

    Zheng, Shiqiang; Feng, Rui

    2016-03-01

    This paper introduces a feedforward control strategy combined with a novel adaptive notch filter to solve the problem of rotor imbalance in high-speed Magnetically Suspended Centrifugal Compressors (MSCCs). Unbalance vibration force of rotor in MSCC is mainly composed of current stiffness force and displacement stiffness force. In this paper, the mathematical model of the unbalance vibration with the proportional-integral-derivative (PID) control laws is presented. In order to reduce the unbalance vibration, a novel adaptive notch filter is proposed to identify the synchronous frequency displacement of the rotor as a compensation signal to eliminate the current stiffness force. In addition, a feedforward channel from position component to control output is introduced to compensate displacement stiffness force to achieve a better performance. A simplified inverse model of power amplifier is included in the feedforward channel to reject the degrade performance caused by its low-pass characteristic. Simulation and experimental results on a MSCC demonstrate a significant effect on the synchronous vibration suppression of the magnetically suspended rotor at a high speed.

  2. Membrane Transport in Isolated Vesicles from Sugarbeet Taproot 1

    PubMed Central

    Briskin, Donald P.; Thornley, W. Robert; Wyse, Roger E.

    1985-01-01

    Sealed membrane vesicles were isolated from homogenates of sugarbeet (Beta vulgaris L.) taproot by a combination of differential centrifugation, extraction with KI, and dextran gradient centrifugation. Relative to the KI-extracted microsomes, the content of plasma membranes, mitochondrial membranes, and Golgi membranes was much reduced in the final vesicle fraction. A component of ATPase activity that was inhibited by nitrate co-enriched with the capacity of the vesicles to form a steady state pH gradient during the purification procedure. This suggests that the nitrate-sensitive ATPase may be involved in driving H+-transport, and this is consistent with the observation that H+-transport, in the final vesicle fraction was inhibited by nitrate. Proton transport in the sugarbeet vesicles was substrate specific for ATP, insensitive to sodium vanadate and oligomycin but was inhibited by diethylstilbestrol and N,N′-dicyclohexylcarbodiimide. The formation of a pH gradient in the vesicles was enhanced by halide ions in the sequence I− > Br− > Cl− while F− was inhibitory. These stimulatory effects occur from both a direct stimulation of the ATPase by anions and a reduction in the vesicle membrane potential. In the presence of Cl−, alkali cations reduce the pH gradient relative to that observed with bis-tris-propane, possibly by H+/alkali cation exchange. Based upon the properties of the H+-transporting vesicles, it is proposed that they are most likely derived from the tonoplast so that this vesicle preparation would represent a convenient system for studying the mechanism of transport at this membrane boundary. PMID:16664342

  3. Acute spinal injury after centrifuge training in asymptomatic fighter pilots.

    PubMed

    Kang, Kyung-Wook; Shin, Young Ho; Kang, Seungcheol

    2015-04-01

    Many countries have hypergravity training centers using centrifuges for pilots to cope with a high gravity (G) environment. The high G training carries potential risk for the development of spinal injury. However, no studies evaluated the influence of centrifuge training on the spines of asymptomatic fighter pilots on a large scale. Study subjects were 991 male fighter pilots with high G training at one institution. Subject variables included information about physical characteristics, flight hours of pilots prior to the training, and G force exposure related factors during training. The two dependent variables were whether the pilots developed acute spinal injury after training and the severity of the injury (major/minor). The incidence of acute spinal injury after high G training was 2.3% (23 of 991 subjects). There were 19 subjects who developed minor injury and 4 subjects who developed a herniated intervertebral disc, which is considered a major injury. In multivariate analysis, only the magnitude of G force during training was significantly related to the development of acute spinal injury. However, there was no significant factor related to the severity of the injury. These results suggest that high G training could cause negative effects on fighter pilots' spines. The magnitude of G force during training seemed to be the most significant factor affecting the occurrence of acute spinal injury.

  4. Development of a Passive Liquid Valve (PLV) Utilizing a Pressure Equilibrium Phenomenon on the Centrifugal Microfluidic Platform

    PubMed Central

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Bahari, Norulain; Arof, Hamzah; Rothan, Hussin A.; Yusof, Rohana; Madou, Marc

    2015-01-01

    In this paper, we propose an easy-to-implement passive liquid valve (PLV) for the microfluidic compact-disc (CD). This valve can be implemented by introducing venting chambers to control the air flow of the source and destination chambers. The PLV mechanism is based on equalizing the main forces acting on the microfluidic CD (i.e., the centrifugal and capillary forces) to control the burst frequency of the source chamber liquid. For a better understanding of the physics behind the proposed PLV, an analytical model is described. Moreover, three parameters that control the effectiveness of the proposed valve, i.e., the liquid height, liquid density, and venting chamber position with respect to the CD center, are tested experimentally. To demonstrate the ability of the proposed PLV valve, microfluidic liquid switching and liquid metering are performed. In addition, a Bradford assay is performed to measure the protein concentration and evaluated in comparison to the benchtop procedure. The result shows that the proposed valve can be implemented in any microfluidic process that requires simplicity and accuracy. Moreover, the developed valve increases the flexibility of the centrifugal CD platform for passive control of the liquid flow without the need for an external force or trigger. PMID:25723143

  5. Development of a passive liquid valve (PLV) utilizing a pressure equilibrium phenomenon on the centrifugal microfluidic platform.

    PubMed

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Bahari, Norulain; Arof, Hamzah; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-02-25

    In this paper, we propose an easy-to-implement passive liquid valve (PLV) for the microfluidic compact-disc (CD). This valve can be implemented by introducing venting chambers to control the air flow of the source and destination chambers. The PLV mechanism is based on equalizing the main forces acting on the microfluidic CD (i.e., the centrifugal and capillary forces) to control the burst frequency of the source chamber liquid. For a better understanding of the physics behind the proposed PLV, an analytical model is described. Moreover, three parameters that control the effectiveness of the proposed valve, i.e., the liquid height, liquid density, and venting chamber position with respect to the CD center, are tested experimentally. To demonstrate the ability of the proposed PLV valve, microfluidic liquid switching and liquid metering are performed. In addition, a Bradford assay is performed to measure the protein concentration and evaluated in comparison to the benchtop procedure. The result shows that the proposed valve can be implemented in any microfluidic process that requires simplicity and accuracy. Moreover, the developed valve increases the flexibility of the centrifugal CD platform for passive control of the liquid flow without the need for an external force or trigger.

  6. Sensorimotor adaptation to inertial forces in a multi-force environment does not depend on the number of targets: indirect validation of the altered-proprioception hypothesis.

    PubMed

    Bourdin, C; Bock, O

    2006-11-20

    The ability of our sensorimotor system to adapt to changing and complex environmental demands has been under experimental scrutiny for more than a century. Previous works have shown that aimed arm movements adapt quickly and completely to Coriolis force, but incompletely to the combination of Coriolis and centrifugal forces without visual cues. Two hypotheses may be advanced to explain this discrepancy: the workspace-exploration hypothesis, and the degraded-proprioception hypothesis. The aim of this study was to distinguish between the above two alternatives by comparing adaptive improvement during off-axis rotation in subjects pointing at one, three or seven different targets in complete darkness. Two main results emerge: (a) off-axis rotation led initially to errors in the direction of Coriolis force and in the opposite direction of the centrifugal force; (b) the size of the visited workspace has no effect on the way the subjects adapt to a multi-force environment. The lack of a target-number effect and the persistence of lateral errors in the pointing movements performed during rotation of the platform, support the degraded-proprioception rather than the workspace-exploration hypothesis of adaptation to a multi-force environment.

  7. Centrifugal Modelling of Soil Structures. Part I. Centrifugal Modelling of Slope Failures.

    DTIC Science & Technology

    1979-03-01

    comparing successive photographs in which soil movement was noted by the change in position of the original grid of silvered indicator balls . Inherent in...SECIJ RITY CLASSIFICATION OF THIS PAGE(1Thon Pat& Entered) of uplift forces was also observed. In nineteen coal mine waste embankment dam models...In’nineteen coal mine waste embankment dam models, throughout which the soil particle size distribution was altered for modelling of dif- ferent

  8. Binary centrifugal microfluidics enabling novel, digital addressable functions for valving and routing.

    PubMed

    Wang, Guanghui; Tan, Jie; Tang, Minghui; Zhang, Changbin; Zhang, Dongying; Ji, Wenbin; Chen, Junhao; Ho, Ho-Pui; Zhang, Xuping

    2018-03-16

    Centrifugal microfluidics or lab-on-a-disc (LOAD) is a promising branch of lab-on-a-chip or microfluidics. Besides effective fluid transportation and inherently available density-based sample separation in centrifugal microfluidics, uniform actuation of flow on the disc makes the platform compact and scalable. However, the natural radially outward centrifugal force in a LOAD system limits its capacity to perform complex fluid manipulation steps. In order to increase the fluid manipulation freedom and integration capacity of the LOAD system, we propose a binary centrifugal microfluidics platform. With the help of Euler force, our platform allows free switching of both left and right states based on a rather simple mechanical structure. The periodical switching of state would provide a "clock" signal for a sequence of droplet binary logic operations. With the binary state platform and the "clock" signal, we can accurately handle the droplet separately in each time step with a maximum main frequency of about 10 S s-1 (switching per second). Apart from droplet manipulations such as droplet generation and metering, we also demonstrate a series of droplet logic operations, such as binary valving, droplet routing and digital addressable droplet storage. Furthermore, complex bioassays such as the Bradford assay and DNA purification assay are demonstrated on a binary platform, which is totally impossible for a traditional LOAD system. Our binary platform largely improves the capability for logic operation on the LOAD platform, and it is a simple and promising approach for microfluidic lab-on-a-disc large-scale integration.

  9. Wetting dynamics of a collapsing fluid hole

    NASA Astrophysics Data System (ADS)

    Bostwick, J. B.; Dijksman, J. A.; Shearer, M.

    2017-01-01

    The collapse dynamics of an axisymmetric fluid cavity that wets the bottom of a rotating bucket bound by vertical sidewalls are studied. Lubrication theory is applied to the governing field equations for the thin film to yield an evolution equation that captures the effect of capillary, gravitational, and centrifugal forces on this converging flow. The focus is on the quasistatic spreading regime, whereby contact-line motion is governed by a constitutive law relating the contact-angle to the contact-line speed. Surface tension forces dominate the collapse dynamics for small holes with the collapse time appearing as a power law whose exponent compares favorably to experiments in the literature. Gravity accelerates the collapse process. Volume dependence is predicted and compared with experiment. Centrifugal forces slow the collapse process and lead to complex dynamics characterized by stalled spreading behavior that separates the large and small hole asymptotic regimes.

  10. The effects of erythrocyte deformability upon hematocrit assessed by the conductance method.

    PubMed

    Hayashi, Yoshihito; Katsumoto, Yoichi; Oshige, Ikuya; Omori, Shinji; Yasuda, Akio; Asami, Koji

    2009-04-21

    A comparative study of centrifugation and conductance methods for the estimation of cell volume fraction (phi) was performed to examine whether the strong forces exerted upon erythrocytes during centrifugation affect their volume, and the results are discussed in terms of erythrocyte deformability. Rabbit erythrocytes of four shapes (spherocytes, echinocytes, stomatocyte-like enlarged erythrocytes and discocytes) were prepared by controlling the pH of the suspending media. The packed cell volumes of the suspensions were measured by standard hematocrit determination methods using centrifugation in capillary tubes. Simultaneously, the same suspensions and their supernatants were used in dielectric spectroscopy measurements, and the low-frequency limits of their conductivities were used for the numerical estimation of phi. The hematocrit values of spherocytes and echinocytes were markedly less than the volume fractions obtained by the conductance method. Namely, the centrifugation reduced the cell volume. For enlarged erythrocytes and discocytes, however, the reduction of cell volume was not observed. These findings showed that phi obtained by the centrifugation method can be greatly affected by the deformability of the cells, but the level of the effect depends on the cell types. Consequently, phi obtained by the centrifugation method should be carefully interpreted.

  11. Levitation forces of a bulk YBCO superconductor in gradient varying magnetic fields

    NASA Astrophysics Data System (ADS)

    Jiang, J.; Gong, Y. M.; Wang, G.; Zhou, D. J.; Zhao, L. F.; Zhang, Y.; Zhao, Y.

    2015-09-01

    The levitation forces of a bulk YBCO superconductor in gradient varying high and low magnetic fields generated from a superconducting magnet were investigated. The magnetic field intensity of the superconducting magnet was measured when the exciting current was 90 A. The magnetic field gradient and magnetic force field were both calculated. The YBCO bulk was cooled by liquid nitrogen in field-cooling (FC) and zero-field-cooling (ZFC) condition. The results showed that the levitation forces increased with increasing the magnetic field intensity. Moreover, the levitation forces were more dependent on magnetic field gradient and magnetic force field than magnetic field intensity.

  12. Continuous centrifuge decelerator for polar molecules.

    PubMed

    Chervenkov, S; Wu, X; Bayerl, J; Rohlfes, A; Gantner, T; Zeppenfeld, M; Rempe, G

    2014-01-10

    Producing large samples of slow molecules from thermal-velocity ensembles is a formidable challenge. Here we employ a centrifugal force to produce a continuous molecular beam with a high flux at near-zero velocities. We demonstrate deceleration of three electrically guided molecular species, CH3F, CF3H, and CF3CCH, with input velocities of up to 200  m s(-1) to obtain beams with velocities below 15  m s(-1) and intensities of several 10(9)  mm(-2) s(-1). The centrifuge decelerator is easy to operate and can, in principle, slow down any guidable particle. It has the potential to become a standard technique for continuous deceleration of molecules.

  13. Characteristics of Helical Flow through Neck Cutoffs

    NASA Astrophysics Data System (ADS)

    Richards, D.; Konsoer, K. M.; Turnipseed, C.; Willson, C. S.

    2017-12-01

    Meander cutoffs and oxbows lakes are a ubiquitous feature of riverine landscapes yet there is a paucity of detailed investigations concentrated on the three-dimensional flow structure through evolving neck cutoffs. The purpose of this research is to investigate and characterize helical flow through neck cutoffs with two different planform configurations: elongate meander loops and serpentine loops. Three-dimensional velocity measurements was collected with an acoustic Doppler current profiler for five cutoffs on the White River, Arkansas. Pronounced helical flow was found through all elongate loop cutoff sites, formed from the balance between centrifugal force resulting from the curving of flow through the cutoff channel and pressure gradient force resulting from water surface super-elevation between primary flow and flow at the entrance and exit of the abandoned loop. The sense of motion of the helical flow caused near-surface fluid to travel outward toward the abandoned loop while near-bed fluid was redirected toward the downstream channel. Another characteristic of the helical flow structure for elongate loop cutoffs was the reversal of helical flow over a relatively short distance, causing patterns of secondary circulation that differed from typical patterns observed through curved channels with point bars. Lastly, helical flow was revealed within zones of strong flow recirculation, enhanced by an exchange of streamwise momentum between shear layers.

  14. Inertial Oscillation of a Vertical Rotating Draft with Application to a Supercell Storm: Video Supplement to NASA-TP-3230

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Stock, Larry V.

    1992-01-01

    In this video (8 min., color, sound, VHS), animation depicts the inertial oscillation of a new mathematical model ('vertical rotating draft') for spinning up a single supercell storm. The oscillation consists of a long quiescent phase when the draft is large in diameter and rotates anticyclonically and a short intense phase when the draft is small and cyclonic. During the intense phase, the rotating draft resembles a supercell. The physical basis for the oscillation is depicted by tracking air parcels in the draft as they move along inertial circles (projected on a horizontal plane), where the horizontal pressure gradient is zero and the Coriolis force balances the centrifugal force. A side view of the oscillation shows that contraction and expansion are linked, respectively, to buoyantly driven compressible downdraft and updraft. An aerial view tracks the draft as it moves above the surface of the Earth and turns to the right during the intense phase. Radar echoes from a supercell storm are superimposed for comparison. The data appear to support only the intense phase. A critical experiment would measure the predominantly downward flow that theoretically occurs before the right turn in a supercell track and causes contraction and spin-up.

  15. Centrifugation-assisted Assembly of Colloidal Silica into Crack-Free and Transferrable Films with Tunable Crystalline Structures

    PubMed Central

    Fan, Wen; Chen, Min; Yang, Shu; Wu, Limin

    2015-01-01

    Self-assembly of colloidal particles into colloidal films has many actual and potential applications. While various strategies have been developed to direct the assembly of colloidal particles, fabrication of crack-free and transferrable colloidal film with controllable crystal structures still remains a major challenge. Here we show a centrifugation-assisted assembly of colloidal silica spheres into free-standing colloidal film by using the liquid/liquid interfaces of three immiscible phases. Through independent control of centrifugal force and interparticle electrostatic repulsion, polycrystalline, single-crystalline and quasi-amorphous structures can be readily obtained. More importantly, by dehydration of silica particles during centrifugation, the spontaneous formation of capillary water bridges between particles enables the binding and pre-shrinkage of the assembled array at the fluid interface. Thus the assembled colloidal films are not only crack-free, but also robust and flexible enough to be easily transferred on various planar and curved substrates. PMID:26159121

  16. Separation of cells from the rat anterior pituitary gland

    NASA Technical Reports Server (NTRS)

    Hymer, W. C.; Hatfield, J. Michael

    1984-01-01

    Data concerned with analyzing the cellular organization of the rat anterior pituitary gland are examined. The preparation of the cell suspensions and the methods used to separate pituitary cell types are described. Particular emphasis is given to velocity sedimentation at unit gravity, density gradient centrifugation, affinity methods, fluorescence activated cell sorting, and density gradient and continuous-flow electrophoresis. The difficulties encountered when attempting to compare data from different pituitary cell separation studies are discussed, and results from various experiments are presented. The functional capabilities of the separated cell populations can be tested in various culture systems.

  17. Articulated Multimedia Physics, Lesson 10, Circular Motion.

    ERIC Educational Resources Information Center

    New York Inst. of Tech., Old Westbury.

    As the tenth lesson of the Articulated Multimedia Physics Course, instructional materials relating to circular motion are presented in this study guide. The topics are concerned with instantaneous velocity, centripetal force, centrifugal force, and satellite paths. The content is arranged in scrambled form, and the use of matrix transparencies is…

  18. Prevalence and genotypes of enterocytozoon bieneusi in weaned beef calves on cow-calf operations in the United States

    USDA-ARS?s Scientific Manuscript database

    To determine the prevalence and genotype distribution of Enterocytozoon bieneusi in weaned beef calves in the United States, fecal samples were collected from 819 calves (6-18 months of age) from 49 operations. Feces were sieved and subjected to density gradient centrifugation to remove fecal debri...

  19. Annular Seals of High Energy Centrifugal Pumps: Presentation of Full Scale Measurement

    NASA Technical Reports Server (NTRS)

    Florjancic, S.; Stuerchler, R.; Mccloskey, T.

    1991-01-01

    Prediction of rotordynamic behavior for high energy concentration centrifugal pumps is a challenging task which still imposes considerable difficulties. While the mechanical modeling of the rotor is solved most satisfactorily by finite element techniques, accurate boundary conditions for arbitrary operating conditions are known for journal bearings only. Little information is available on the reactive forces of annular seals, such as neck ring and interstage seals and balance pistons, and on the impeller interaction forces. The present focus is to establish reliable boundary conditions at annular seals. For this purpose, a full scale test machine was set up and smooth and serrated seal configurations measured. Dimensionless coefficients are presented and compared with a state of the art theory.

  20. Subsynchronous vibrations in a high pressure centrifugal compressor: A case history

    NASA Technical Reports Server (NTRS)

    Evans, B. F.; Smalley, A. J.

    1984-01-01

    Two distinct aerodynamically excited vibrations in a high pressure low flow centrifugal compressor are documented. A measured vibration near 21% of running speed was identified as a nonresonant forced vibration which results from rotating stall in the diffuser; a measured vibration near 50% of running speed was identified as a self excited vibration sustained by cross coupling forces acting at the compressor wheels. The dependence of these characteristics on speed, discharge pressure, and changes in bearing design are shown. The exciting mechanisms of diffuser stall and aerodynamic cross coupling are evidenced. It is shown how the rotor characteristics are expected to change as a result of modifications. The operation of the compressor after the modifications is described.

  1. Concept designs of nonrotating-type centrifugal blood pump and basic study on output characteristics of the oscillating disk-type centrifugal pump.

    PubMed

    Kabei, N; Tuichiya, K; Sakurai, Y

    1994-09-01

    When designing a turbo-type blood pump as an artificial heart, the gap between a rotating shaft and a pump housing should be perfectly sealed to prevent any leakage or contamination through a seal. In addition, blood coagulation in a blood chamber must be avoided. To overcome these problems, we proposed five different nonrotating-type turbo pumps: a caudal-fin-type axial-flow pump, a caudal-fin-type centrifugal pump, a nutating-column-type centrifugal pump, a nutating-collapsible-tube-type centrifugal pump, and an oscillating-disk-type centrifugal pump. We selected and developed the oscillating-disk-type centrifugal pump that consists of a disk, a driving rod, a seal, an oscillation mechanism, and a pump housing. The disk is mounted on the end of the rod, which is connected to a high-speed DC motor through an oscillation mechanism. The rod and the disk do not rotate, but they oscillate in the pump housing. This movement of the disk generates forward fluid flow around the axis (i.e., the rotational fluid flow). Centrifugal force due to fluid rotation supports the pressure difference between the outlet and the inlet. The diameter of the disk is 39 mm, the maximum inner diameter of the pump housing is 40 mm, and the volume of the blood chamber for 25 degrees' oscillation is 16.9 ml. The performance of the pump was tested in a mock circulatory system.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Evaluation of a reduced centrifugation time and higher centrifugal force on various general chemistry and immunochemistry analytes in plasma and serum.

    PubMed

    Møller, Mette F; Søndergaard, Tove R; Kristensen, Helle T; Münster, Anna-Marie B

    2017-09-01

    Background Centrifugation of blood samples is an essential preanalytical step in the clinical biochemistry laboratory. Centrifugation settings are often altered to optimize sample flow and turnaround time. Few studies have addressed the effect of altering centrifugation settings on analytical quality, and almost all studies have been done using collection tubes with gel separator. Methods In this study, we compared a centrifugation time of 5 min at 3000 ×  g to a standard protocol of 10 min at 2200 ×  g. Nine selected general chemistry and immunochemistry analytes and interference indices were studied in lithium heparin plasma tubes and serum tubes without gel separator. Results were evaluated using mean bias, difference plots and coefficient of variation, compared with maximum allowable bias and coefficient of variation used in laboratory routine quality control. Results For all analytes except lactate dehydrogenase, the results were within the predefined acceptance criteria, indicating that the analytical quality was not compromised. Lactate dehydrogenase showed higher values after centrifugation for 5 min at 3000 ×  g, mean bias was 6.3 ± 2.2% and the coefficient of variation was 5%. Conclusions We found that a centrifugation protocol of 5 min at 3000 ×  g can be used for the general chemistry and immunochemistry analytes studied, with the possible exception of lactate dehydrogenase, which requires further assessment.

  3. Effect of Speed (Centrifugal Load) on Gear Crack Propagation Direction

    NASA Technical Reports Server (NTRS)

    Lewicki, David G.

    2001-01-01

    The effect of rotational speed (centrifugal force) on gear crack propagation direction was explored. Gears were analyzed using finite element analysis and linear elastic fracture mechanics. The analysis was validated with crack propagation experiments performed in a spur gear fatigue rig. The effects of speed, rim thickness, and initial crack location on gear crack propagation direction were investigated. Crack paths from the finite element method correlated well with those deduced from gear experiments. For the test gear with a backup ratio (rim thickness divided by tooth height) of nib = 0.5, cracks initiating in the tooth fillet propagated to rim fractures when run at a speed of 10,000 rpm and became tooth fractures for speeds slower than 10,000 rpm for both the experiments and anal sis. From additional analysis, speed had little effect on crack propagation direction except when initial crack locations were near the tooth/rim fracture transition point for a given backup ratio. When at that point, higher speeds tended to promote rim fracture while lower speeds (or neglecting centrifugal force) produced tooth fractures.

  4. Weight, gravitation, inertia, and tides

    NASA Astrophysics Data System (ADS)

    Pujol, Olivier; Lagoute, Christophe; Pérez, José-Philippe

    2015-11-01

    This paper deals with the factors that influence the weight of an object near the Earth's surface. They are: (1) the Earth's gravitational force, (2) the centrifugal force due to the Earth's diurnal rotation, and (3) tidal forces due to the gravitational field of the Moon and Sun, and other solar system bodies to a lesser extent. Each of these three contributions is discussed and expressions are derived. The relationship between weight and gravitation is thus established in a direct and pedagogical manner readily understandable by undergraduate students. The analysis applies to the Newtonian limit of gravitation. The derivation is based on an experimental (or operational) definition of weight, and it is shown that it coincides with the Earth’s gravitational force modified by diurnal rotation around a polar axis and non-uniformity of external gravitational bodies (tidal term). Two examples illustrate and quantify these modifications, respectively the Eötvös effect and the oceanic tides; tidal forces due to differential gravitation on a spacecraft and an asteroid are also proposed as examples. Considerations about inertia are also given and some comments are made about a widespread, yet confusing, explanation of tides based on a centrifugal force. Finally, the expression of the potential energy of the tide-generating force is established rigorously in the appendix.

  5. Heat Transfer Coefficient at Cast-Mold Interface During Centrifugal Casting: Calculation of Air Gap

    NASA Astrophysics Data System (ADS)

    Bohacek, Jan; Kharicha, Abdellah; Ludwig, Andreas; Wu, Menghuai; Karimi-Sibaki, Ebrahim

    2018-06-01

    During centrifugal casting, the thermal resistance at the cast-mold interface represents a main blockage mechanism for heat transfer. In addition to the refractory coating, an air gap begins to form due to the shrinkage of the casting and the mold expansion, under the continuous influence of strong centrifugal forces. Here, the heat transfer coefficient at the cast-mold interface h has been determined from calculations of the air gap thickness d a based on a plane stress model taking into account thermoelastic stresses, centrifugal forces, plastic deformations, and a temperature-dependent Young's modulus. The numerical approach proposed here is rather novel and tries to offer an alternative to the empirical formulas usually used in numerical simulations for a description of a time-dependent heat transfer coefficient h. Several numerical tests were performed for different coating thicknesses d C, rotation rates Ω, and temperatures of solidus T sol. Results demonstrated that the scenario at the interface is unique for each set of parameters, hindering the possibility of employing empirical formulas without a preceding experiment being performed. Initial values of h are simply equivalent to the ratio of the coating thermal conductivity and its thickness ( 1000 Wm-2 K-1). Later, when the air gap is formed, h drops exponentially to values at least one order of magnitude smaller ( 100 Wm-2 K-1).

  6. LBNP as useful tool for pilot candidates selection to the Polish Air Force: a preliminary study.

    PubMed

    Romuald, M; Mariusz, Z; Artur, D; Krzysztof, R

    2001-07-01

    Candidates to the Polish Air Force are to fulfill strict medical conditions. Every candidate, wanting to become a fighter pilot or not, has to pass a rigorous centrifuge examination. This is a costly and especially stressful process for the candidates, as first-timers. This article explores possibility for different approach to candidates fitness to fly assessment. 14 candidates (21-22 yrs old) were subjected to a regular GOR centrifuge profile (0.1 G/s; up to +7.0 Gz; unprotected) and to lower body negative pressure (LBNP) examination (2 min. rest period followed by 3 min. at -40 mm Hg; supine position). Both, centrifuge and LBNP examinations were carried out the same day, with about 1 hour gap between them. ECG and impedance cardiography (ICG) were being recorded during both tests. The following parameters were calculated: HR and QZ (time between ventricular depolarization [beginning of the Q wave in ECG] and local maximum of the first derivative [dZ/dt] in ICG). QZ was considered to be an effective measure of dynamic heart function. +Gz tolerance for the group was +5.94 +/- 0.98 Gz. Correlation between +Gz tolerance and QZ values during LBNP test (-40 mm Hg) for all subjects was equal to r=0.6. Correlation between sets of parameters (canonical analysis) for LBNP and centrifuge was equal to r=0.78. Both results were statistically insignificant (p<0.09). Baseline HR values were 121 +/- 19 bpm and 75 +/- 12 bpm, and maximal HR values were 172 +/- 21 bpm and 81 +/- 13 bpm, respectively for centrifuge and LBNP. For both, baseline and maximal HR during LBNP and G exposure canonical correlation was equal to r=0.72. The results were statistically not significant, however. Centrifuge examination is much more stressful than LBNP test. This could have implication on the objective results of centrifuge test. The results may suggest that LBNP test could be a used in pilot candidates selection, especially those presenting high baseline HR values.

  7. Introducing Motion in a Circle.

    ERIC Educational Resources Information Center

    Roche, John

    2001-01-01

    Motion in a circle troubled Newton and his contemporaries and troubles students today. Presents a clear presentation of certain aspects, particularly centripetal acceleration and centrifugal force. (Author/MM)

  8. Application of CFD in Bioprocessing: Separation of mammalian cells using disc stack centrifuge during production of biotherapeutics.

    PubMed

    Shekhawat, Lalita Kanwar; Sarkar, Jayati; Gupta, Rachit; Hadpe, Sandeep; Rathore, Anurag S

    2018-02-10

    Centrifugation continues to be one of the most commonly used unit operations for achieving efficient harvest of the product from the mammalian cell culture broth during production of therapeutic monoclonal antibodies (mAbs). Since the mammalian cells are known to be shear sensitive, optimal performance of the centrifuge requires a balance between productivity and shear. In this study, Computational Fluid Dynamics (CFD) has been successfully used as a tool to facilitate efficient optimization. Multiphase Eulerian-Eulerian model coupled with Gidaspow drag model along with Eulerian-Eulerian k-ε mixture turbulence model have been used to quantify the complex hydrodynamics of the centrifuge and thus evaluate the turbulent stresses generated by the centrifugal forces. An empirical model has been developed by statistical analysis of experimentally observed cell lysis data as a function of turbulent stresses. An operating window that offers the optimal balance between high productivity, high separation efficiency, and low cell damage has been identified by use of CFD modeling. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Reduction of relative centrifugation force within injectable platelet-rich-fibrin (PRF) concentrates advances patients' own inflammatory cells, platelets and growth factors: the first introduction to the low speed centrifugation concept.

    PubMed

    Choukroun, J; Ghanaati, S

    2018-02-01

    The aim of this study was to analyze systematically the influence of the relative centrifugation force (RCF) on leukocytes, platelets and growth factor release within fluid platelet-rich fibrin matrices (PRF). Systematically using peripheral blood from six healthy volunteers, the RCF was reduced four times for each of the three experimental protocols (I-III) within the spectrum (710-44 g), while maintaining a constant centrifugation time. Flow cytometry was applied to determine the platelets and leukocyte number. The growth factor concentration was quantified 1 and 24 h after clotting using ELISA. Reducing RCF in accordance with protocol-II (177 g) led to a significantly higher platelets and leukocytes numbers compared to protocol-I (710 g). Protocol-III (44 g) showed a highly significant increase of leukocytes and platelets number in comparison to -I and -II. The growth factors' concentration of VEGF and TGF-β1 was significantly higher in protocol-II compared to -I, whereas protocol-III exhibited significantly higher growth factor concentration compared to protocols-I and -II. These findings were observed among 1 and 24 h after clotting, as well as the accumulated growth factor concentration over 24 h. Based on the results, it has been demonstrated that it is possible to enrich PRF-based fluid matrices with leukocytes, platelets and growth factors by means of a single alteration of the centrifugation settings within the clinical routine. We postulate that the so-called low speed centrifugation concept (LSCC) selectively enriches leukocytes, platelets and growth factors within fluid PRF-based matrices. Further studies are needed to evaluate the effect of cell and growth factor enrichment on wound healing and tissue regeneration while comparing blood concentrates gained by high and low RCF.

  10. On radiation forces acting on a transparent nanoparticle in the field of a focused laser beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Afanas'ev, A A; Rubinov, A N; Gaida, L S

    2015-10-31

    Radiation forces acting on a transparent spherical nanoparticle in the field of a focused Gaussian laser beam are studied theoretically in the Rayleigh scattering regime. Expressions are derived for the scattering force and Cartesian components of the gradient force. The resultant force acting on a nanoparticle located in the centre of a laser beam is found. The parameters of the focused beam and optical properties of the nanoparticle for which the longitudinal component of the gradient force exceeds the scattering force are determined. Characteristics of the transverse gradient force are discussed. (nanophotonics)

  11. Spatial Orientation and Balance Control Changes Induced by Altered Gravito-Inertial Force Vectors

    NASA Technical Reports Server (NTRS)

    Kaufman, Galen D.; Wood, Scott J.; Gianna, Claire C.; Black, F. Owen; Paloski, William H.; Dawson, David L. (Technical Monitor)

    1999-01-01

    Seventeen healthy and eight vestibular deficient subjects were exposed to an interaural centripetal acceleration of 1 G (resultant 45 deg roll tilt of 1.4 G) on a 0.8 meter radius centrifuge for a period of 90 minutes in the dark. The subjects sat with head fixed upright, except every 4 of 10 minutes when instructed to rotate their head so that their nose and eyes pointed towards a visual point switched on every 3 to 5 seconds at random places (within +/- 30 deg) in the Earth horizontal plane. Motion sickness caused some subjects to limit their head movements during significant portions of the 90 minute period, and led three normal subjects to stop the test earlier. Eye movements, including directed saccades for subjective Earth- and head-referenced planes, were recorded before, during, and immediately after centrifugation using electro-oculography. Postural stability measurements were made before and within ten minutes after centrifugation. In normal subjects, postural sway and multisegment body kinematics were gathered during an eyes-closed head movement cadence (sway-referenced support platform), and in response to translational/rotational platform perturbations. A significant increase in postural sway, segmental motion amplitude and hip frequency was observed after centrifugation. This effect was short-lived, with a recovery time of several postural test trials. There were also asymmetries in the direction of post-centrifugation center of sway and head tilt which depended on the subject's orientation during the centrifugation adaptation period (left ear or right ear out). To delineate the effect of the magnitude of the gravito-inertial vector versus its direction during the adaptive centrifugation period, we tilted eight normal subjects in the roll axis at a 45 deg angle in the dark for 90 minutes without rotational motion. Their postural responses did not change following the period of tilt. Based on verbal reports, normal subjects overestimated roll-tilt during 90 minutes of both tilt and centrifugation stimuli. Subjective estimates of head-horizontal, provided by directed saccades, revealed significant errors after approximately 30 minutes that tended to increase only in the group who underwent centrifugation. Immediately after centrifugation, subjects reported feeling tilted on average 10 degrees in the opposite direction, which was in agreement with the direction of their earth-directed saccades. In vestibular deficient (VD) subjects, postural sway was measured using a sway-referenced or earth-fixed support surface, and with or without a head movement sequence. 'Me protocol was selected for each patient during baseline testing, and corresponded to the most challenging condition in which the patient was able to maintain balance with eyes closed. Bilaterally VD subjects showed no postural decrement after centrifugation, while unilateral VD subjects had varying degrees of decrement. Unilateral VD subjects were tested twice; they underwent centrifugation both with right ear out and left ear out. Their post-centrifuation center of sway shifted at right angles depending on the centrifuge GIF orientation. Bilateral VD subjects bad shifts as well, but no consistent directional trend. VD subjects underestimated roll-tilt during centrifugation, These results suggest that orientation of the gravito-inertial vector and its magnitude arc both used by the central nervous system for calibration of multiple orientation systems. A change in the background gravito-inertial force (otolith input) can rapidly initiate postural and perceptual adaptation in several sensorimotor systems, independent of a structured visual surround.

  12. Biological Experiments in Microgravity Conditions Using Magnetic Micro- and Nano-Particles

    NASA Astrophysics Data System (ADS)

    Nechitailo, Galina S.; Kuznetsov, Anatoli; Kuznetsov, Oleg

    2016-07-01

    Gravity affects all living organisms on Earth, and plays a role in multiple processes in them. In microgravity conditions (e.g., on board of a spacecraft) many of these processes are disturbed, e.g., spatial orientation is lost, mass and heat exchange is distorted, many adaptive mechanisms no longer function, etc. Negation of these adverse effects by creation of pseudo-gravity to by centrifugation is complicated, expensive and unpractical. We propose to use naturally occurring magnetic heterogeneity of all living cells and high gradient magnetic fields as an alternative approach to negating the adverse effects of microgravity on living systems. In non-uniform magnetic field, magnetically heterogeneous objects experience a system of ponderomotive forces. For a weak magnetic particle, the net ponderomotive magnetic force: Fm = Δχ•V•grad(H2/2), where Δχ is the difference of susceptibilities of the particle and the surrounding media, V is the volume of the particle, grad(H2/2) is the dynamic factor of the magnetic field. We studied magnetic heterogeneity of plant gravity receptor cells, prepared and conducted experiments on board of the space station "Mir" on providing a gravity-like stimulus for flax seedlings using high gradient magnetic field ("Magnetogravistat" experiment). Later, a more sophisticated version of this experiment was flown on STS-107. These experiments provided new data on the mechanisms of plant gravity reception and created a method for substituting gravity for a living organism by a force of a different physical nature, to negate the adverse effects of microgravity. Since the ponderomotive force is proportional to the dynamic factor of the field grad(H2/2), the stronger the field, and the faster it changes over distance, the higher is the dynamic factor and the stronger the ponderomotive force. Therefore, in the small vicinity of a small ferromagnetic particle (preferably metallic micro or nano-particles), the forces are very significant even for weak magnetic objects, and can have significant effects on multiple processes in living cells/organisms. It was reported, that such high gradient magnetic fields can affect cell differentiation and cell proliferation processes in ground-based experiments. To prevent oxidation of ultradisperse ferromagnetic particles in aqueous media, it is beneficial to coat their surface with carbon. Suitable protected metallic micro- and nano-particles can be produced by a variety of techniques (CVD, plasmachemistry, joint grinding, etc.). Ferro-carbon particles produced by plasmachemical technique have high sorption capacities for various organic and inorganic compounds (as well as for various cell metabolites), can be formed in rather stable aqueous suspensions, and be controlled (e.g., sedimented) by a magnetic field. This makes these particles a very interesting research tool. In our opinion, biological experiments with ferro-carbon nano-structured particles in microgravity will generate important scientific data and will allow creating new methods of negating the adverse effects of microgravity on living systems.

  13. Kepler's Laws: Demonstration and Derivation Without Calculus

    ERIC Educational Resources Information Center

    Chapman, Seville

    1969-01-01

    Presents a demonstration apparatus for Kepler's three laws of planetary motion consisting of an air-supported "satellite whose orbit on a level table surface is determined by an inverse square force generated by a Peaucellier linkage and long spring. The device can also be used to illustrate centrifugal force, statics, friction, momentum and…

  14. Centrifuge-operated specimen staining method and apparatus

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L. (Inventor); Clarke, Mark S. F. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  15. Stochastic resonance energy harvesting for a rotating shaft subject to random and periodic vibrations: influence of potential function asymmetry and frequency sweep

    NASA Astrophysics Data System (ADS)

    Kim, Hongjip; Che Tai, Wei; Zhou, Shengxi; Zuo, Lei

    2017-11-01

    Stochastic resonance is referred to as a physical phenomenon that is manifest in nonlinear systems whereby a weak periodic signal can be significantly amplified with the aid of inherent noise or vice versa. In this paper, stochastic resonance is considered to harvest energy from two typical vibrations in rotating shafts: random whirl vibration and periodic stick-slip vibration. Stick-slip vibrations impose a constant offset in centrifugal force and distort the potential function of the harvester, leading to potential function asymmetry. A numerical analysis based on a finite element method was conducted to investigate stochastic resonance with potential function asymmetry. Simulation results revealed that a harvester with symmetric potential function generates seven times higher power than that with asymmetric potential function. Furthermore, a frequency-sweep analysis also showed that stochastic resonance has hysteretic behavior, resulting in frequency difference between up-sweep and down-sweep excitations. An electromagnetic energy harvesting system was constructed to experimentally verify the numerical analysis. In contrast to traditional stochastic resonance harvesters, the proposed harvester uses magnetic force to compensate the offset in the centrifugal force. System identification was performed to obtain the parameters needed in the numerical analysis. With the identified parameters, the numerical simulations showed good agreement with the experiment results with around 10% error, which verified the effect of potential function asymmetry and frequency sweep excitation condition on stochastic resonance. Finally, attributed to compensating the centrifugal force offset, the proposed harvester generated nearly three times more open-circuit output voltage than its traditional counterpart.

  16. Histological assessments on the abnormalities of mouse epiphyseal chondrocytes with short term centrifugal loading.

    PubMed

    de Freitas, Paulo Henrique Luiz; Kojima, Taku; Ubaidus, Sobhan; Li, Minqi; Shang, Guangwei; Takagi, Ritsuo; Maeda, Takeyasu; Oda, Kimimitsu; Ozawa, Hidehiro; Amizuka, Norio

    2007-08-01

    We have examined the morphological changes in chondrocytes after exposure to experimental hypergravity. Tibial epiphyseal cartilages of 17-days-old mouse fetuses were exposed to centrifugation at 3G for 16 h mimicking hypergravitational environment (experimental group), or subjected to stationary cultures (control group). Centrifugation did not affect the sizes of epiphyseal cartilage, chondrocyte proliferation, type X collagen-positive hypertrophic zone, and the mRNA expressions of parathyroid hormone-related peptide and fibroblast growth factor receptor III. However, centrifuged chondrocytes showed abnormal morphology and aberrant spatial arrangements, resulting in disrupted chondrocytic columns. Through histochemical assessments, actin filaments were shown to distribute evenly along cell membranes of control proliferative chondrocytes, while chondrocytes subjected to centrifugal force developed a thicker layer of actin filaments. Transmission electron microscopic observations revealed spotty electron-dense materials underlying control chondrocytes' cell membranes, while experimental chondrocytes showed their thick layer. In the intracolumnar regions of the control cartilage, longitudinal electron-dense fibrils were associated with short cytoplasmic processes of normal chondrocytes, indicating assumed cell-tomatrix interactions. These extracellular fibrils were disrupted in the centrifuged samples. Summarizing, altered actin filaments associated with cell membranes, irregular cell shape and disappearance of intracolumnar extracellular fibrils suggest that hypergravity disturbs cell-to-matrix interactions in our cartilage model.

  17. In vitro cell-mediated immunity after thermal injury is not impaired. Density gradient purification of mononuclear cells is associated with spurious (artifactual) immunosuppression.

    PubMed Central

    Xu, D Z; Deitch, E A; Sittig, K; Qi, L; McDonald, J C

    1988-01-01

    Mononuclear cells isolated by density gradient centrifugation from the peripheral blood of burn patients, but not healthy volunteers, are contaminated with large numbers of nonmononuclear cells. These contaminating leukocytes could cause artifactual alterations in standard in vitro tests of lymphocyte function. Thus, we compared the in vitro blastogenic response of density gradient purified leukocytes and T-cell purified lymphocytes from 13 burn patients to mitogenic (PHA) and antigenic stimuli. The mitogenic and antigenic response of the patients' density gradient purified leukocytes were impaired compared to healthy volunteers (p less than 0.01). However, when the contaminating nonlymphocytes were removed, the patients' cells responded normally to both stimuli. Thus, density gradient purified mononuclear cells from burn patients are contaminated by leukocytes that are not phenotypically or functionally lymphocytes. Since the lymphocytes from burn patients respond normally to PHA and alloantigens after the contaminating nonlymphocyte cell population has been removed, it appears that in vitro assays of lymphocyte function using density gradient purified leukocytes may give spurious results. PMID:2973771

  18. Isolation and Characterization of Chloroplast DNA from the Duckweed Spirodela oligorrhiza

    PubMed Central

    van Ee, Jan H.; Veld, Willem A. Man In'T; Planta, Rudi J.

    1980-01-01

    Chloroplast DNA of the duckweed Spirodela oligorrhiza, isolated by CsCl gradient centrifugation, was characterized by its buoyant density, guanine + cytosine content, melting behavior, circularity, and contour length. In all these characteristics, chloroplast DNA of S. oligorrhiza is similar to the chloroplast genomes of other higher plants, except that it has a significantly larger size. Images PMID:16661479

  19. FORTRAN program for calculating velocities in the meridional plane of a turbomachine 1: Centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Vanco, M. R.

    1972-01-01

    The program will determine the velocities in the meridional plane of a backward-swept impeller, a radial impeller, and a vaned diffuser. The velocity gradient equation with the assumption of a hub-to-shroud mean stream surface is solved along arbitrary quasi-orthogonals in the meridional plane. These quasi-orthogonals are fixed straight lines.

  20. Effective removal of equine arteritis virus from stallion semen.

    PubMed

    Morrell, J M; Geraghty, R M

    2006-05-01

    A method of removing equine arteritis virus (EAV) from equine semen used for artificial insemination is urgently needed. Recent medical studies suggest that a double semen processing technique of density gradient centrifugation followed by a 'swim-up' can provide virus-free sperm preparations for assisted reproduction. To investigate the use of the double semen processing technique to obtain virus-free sperm preparations from stallion semen containing EAV. Aliquots of an ejaculate from an uninfected stallion were spiked with virus and processed by the double processing technique. The sperm preparations were tested by PCR for the presence of EAV. The procedure was repeated using an ejaculate from a known shedding stallion, testing processed and unprocessed aliquots by PCR and virus isolation. Virus-free sperm preparations were obtained using the double sperm processing technique. The 'swim-up' step is apparently required to ensure complete virus removal. The double semen processing technique is potentially a useful and simple tool for the removal of EAV from the semen of shedding stallions. The inclusion of density gradient centrifugation and 'swim-up' in protocols for the processing of semen for artificial insemination could help prevent the transmission of viral diseases carried in semen, such as EAV.

  1. Sperm DNA fragmentation in the total and vital fractions before and after density gradient centrifugation: Significance in male fertility diagnosis.

    PubMed

    Punjabi, U; Van Mulders, H; Goovaerts, I; Peeters, K; Clasen, K; Janssens, P; Zemtsova, O; De Neubourg, D

    2018-05-21

    Sperm DNA fragmentation measured by different techniques make comparisons impossible due to lack of standardization. Induction of DNA damage after sperm preparation in the entire fraction has been observed on independent occasions but findings are not consistent. Men presenting at a University hospital setup for infertility treatment. DNA damage via TUNEL assay was validated on fresh semen samples, as conventional semen parameters, to reduce variability of results. Sperm motility in neat semen inversely correlated with sperm DNA fragmentation in the total fraction, but, total count, leukocytes and immature germ cells significantly affected the vital fraction. Sperm DNA fragmentation was observed both in normal and subnormal semen samples, but was significantly different in the total fraction of astheno-, asthenoterato- and oligoteratozoospermic men. After density gradient centrifugation, sperm DNA fragmentation increased significantly in the total but decreased in the vital fraction. Advancing male age significantly influenced damage in the total but not in the vital population. These findings provide opportunities to investigate the significance of the total and the vital fractions both in natural conception and after different assisted reproductive technologies. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Direct measurement of optical trapping force gradient on polystyrene microspheres using a carbon nanotube mechanical resonator.

    PubMed

    Yasuda, Masaaki; Takei, Kuniharu; Arie, Takayuki; Akita, Seiji

    2017-06-06

    Optical tweezers based on optical radiation pressure are widely used to manipulate nanoscale to microscale particles. This study demonstrates direct measurement of the optical force gradient distribution acting on a polystyrene (PS) microsphere using a carbon nanotube (CNT) mechanical resonator, where a PS microsphere with 3 μm diameter is welded at the CNT tip using laser heating. With the CNT mechanical resonator with PS microsphere, we measured the distribution of optical force gradient with resolution near the thermal noise limit of 0.02 pN/μm in vacuum, in which condition enables us to high accuracy measurement using the CNT mechanical resonator because of reduced mechanical damping from surrounding fluid. The obtained force gradient and the force gradient distribution agree well with theoretical values calculated using Lorenz-Mie theory.

  3. Pancreatin-EDTA treatment affects buoyancy of cells in Cohn fraction V protein density gradients without residual effect on cell size.

    PubMed

    Sheridan, J W; Simmons, R J

    1983-12-01

    The buoyancy of suspension-grown Mastocytoma P815 X-2 cells in albumin-rich Cohn fraction V protein (CFVP) density gradients was found to be affected by prior incubation of the cells in pancreatin-EDTA salt solution. Whereas in pH 5.2 CFVP, pancreatin-EDTA treated cells behaved as if of reduced density when compared with the control 'undigested' group, in pH 7.3 CFVP they behaved as if of increased density. By contrast, pancreatin-EDTA treatment had no effect on the buoyancy of mastocytoma cells in polyvinylpyrrolidone-coated colloidal silica (PVP-CS, Percoll T.M.) density gradients of either pH 5.2 or pH 7.3. As cell size determinations failed to reveal alterations in cell size either as a direct result of pancreatin-EDTA treatment or as a combined consequence of such treatment and exposure to CFVP either with or without centrifugation, a mechanism involving a change in cell density other than during the centrifugation process itself seems unlikely. Binding studies employing 125I-CFVP, although indicating that CFVP bound to cells at 4 degrees, failed to reveal a pancreatin-EDTA treatment-related difference in the avidity of this binding. Although the mechanism of the pancreatin-EDTA-induced buoyancy shift in CFVP remains obscure, the absence of such an effect in PVP-CS suggests that the latter cell separation solution may more accurately be used to determine cell density.

  4. [Prognostic value on recovery rates for the application of sperm preparation techniques and their evaluation in sperm function].

    PubMed

    Barroso, Gerardo; Chaya, Miguel; Bolaños, Rubén; Rosado, Yadira; García León, Fernando; Ibarrola, Eduardo

    2005-05-01

    To evaluate sperm recovery and total sperm motility in three different sperm preparation techniques (density gradient, simple washing and swim-up). A total of 290 subjects were randomly evaluated from November 2001 to March 2003. The density gradient method required Isolate (upper and lower layers). Centrifugation was performed at 400 g for 10 minutes and evaluation was done using the Makler counting chamber. The simple washing method included the use of HTF-M complemented with 7.5% of SSS, with centrifugation at 250 g, obtaining at the end 0.5 mL of the sperm sample. The swim-up method required HTF-M complemented with 7.5% of SSS, with an incubation period of 60 minutes at 37 degrees C. The demographic characteristics evaluated through their standard error, 95% ICC, and 50th percentile were similar. The application of multiple comparison tests and analysis of variance showed significant differences between the sperm preparations before and after capacitation. It was observed a superior recovery rate with the density gradient and swim-up methods; nevertheless, the samples used for the simple washing method showed a diminished sperm recovery from the original sample. Sperm preparation techniques have become very useful in male infertility treatments allowing higher sperm recovery and motility rates. The seminal parameters evaluated from the original sperm sample will determine the best sperm preparation technique in those patients who require it.

  5. Systems approach used in the Gas Centrifuge Enrichment Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rooks, W.A. Jr.

    A requirement exists for effective and efficient transfer of technical knowledge from the design engineering team to the production work force. Performance-Based Training (PBT) is a systematic approach to the design, development, and implementation of technical training. This approach has been successfully used by the US Armed Forces, industry, and other organizations. The advantages of the PBT approach are: cost-effectiveness (lowest life-cycle training cost), learning effectiveness, reduced implementation time, and ease of administration. The PBT process comprises five distinctive and rigorous phases: Analysis of Job Performance, Design of Instructional Strategy, Development of Training Materials and Instructional Media, Validation of Materialsmore » and Media, and Implementation of the Instructional Program. Examples from the Gas Centrifuge Enrichment Plant (GCEP) are used to illustrate the application of PBT.« less

  6. Interrelation of the effects caused by the rotation of the whispering gallery modes resonator

    NASA Astrophysics Data System (ADS)

    Dmitriyeva, Anna D.; Filatov, Yuri V.; Shalymov, Egor V.; Venediktov, Vladimir Yu.

    2016-11-01

    Optical whispering gallery modes resonators are characterized by unique properties: ultrahigh quality factor, small amount of the modes and small size. It allows to use them in compact high-precision measuring devices. In particular these resonators can be used in the composition of gyros. For today all researches, devoted to the application of the whispering gallery modes resonators in gyros, deals only with one of induced by the rotation effects (Sagnac effect or the influence of centrifugal forces on the resonator size). In this work we study the interrelation of the effects caused by the rotation of the whispering gallery modes resonator. Also in work we consider the possibility of joint application of both effects (the influence of centrifugal forces and Sagnac effect) for measuring angular velocity.

  7. Lateral shearing optical gradient force in coupled nanobeam photonic crystal cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Han; Zhang, Xingwang; Chau, Fook Siong

    2016-04-25

    We report the experimental observation of lateral shearing optical gradient forces in nanoelectromechanical systems (NEMS) controlled dual-coupled photonic crystal (PhC) nanobeam cavities. With an on-chip integrated NEMS actuator, the coupled cavities can be mechanically reconfigured in the lateral direction while maintaining a constant coupling gap. Shearing optical gradient forces are generated when the two cavity centers are laterally displaced. In our experiments, positive and negative lateral shearing optical forces of 0.42 nN and 0.29 nN are observed with different pumping modes. This study may broaden the potential applications of the optical gradient force in nanophotonic devices and benefit the futuremore » nanooptoelectromechanical systems.« less

  8. Impact of waves on the circulation flow in the Iguasu gas centrifuge

    NASA Astrophysics Data System (ADS)

    Bogovalov, S.; Kislov, V.; Tronin, I.

    2017-01-01

    2D axisymmetric transient flow induced by a pulsed braking force in the Iguasu gas centrifuge (GC) is simulated numerically. The simulation is performed for two cases: transient and stationary. The braking forces averaged over the period of rotation are equal to each other in both cases. The transient case is compared with the stationary case where the flow is excited by the stationary braking force.Two models of the gas cenrifuge is simulated. There are two cameras in the first model and three cameras in the second one. In the transient case for the two cameras model pulsations almost doubles the axial circulation flux in the working camera. In the transient case for the three cameras model the gas flux through the gap in the bottom baffle exceeds on 15 % the same flux in the stationary case for the same gas content and temperature at the walls of the rotor. We argue that the waves can reduce the gas content in the GC on the same 15 %.

  9. METHOD OF PRODUCING DENSE CONSOLIDATED METALLIC REGULUS

    DOEpatents

    Magel, T.T.

    1959-08-11

    A methcd is presented for reducing dense metal compositions while simultaneously separating impurities from the reduced dense metal and casting the reduced parified dense metal, such as uranium, into well consolidated metal ingots. The reduction is accomplished by heating the dense metallic salt in the presence of a reducing agent, such as an alkali metal or alkaline earth metal in a bomb type reacting chamber, while applying centrifugal force on the reacting materials. Separation of the metal from the impurities is accomplished essentially by the incorporation of a constricted passageway at the vertex of a conical reacting chamber which is in direct communication with a collecting chamber. When a centrifugal force is applled to the molten metal and slag from the reduction in a direction collinear with the axis of the constricted passage, the dense molten metal is forced therethrough while the less dense slag is retained within the reaction chamber, resulting in a simultaneous separation of the reduced molten metal from the slag and a compacting of the reduced metal in a homogeneous mass.

  10. Inductrack configuration

    DOEpatents

    Post, Richard Freeman [Walnut Creek, CA

    2006-08-29

    A simple permanent-magnet-excited maglev geometry provides levitation forces and is stable against vertical displacements from equilibrium but is unstable against horizontal displacements. An Inductrack system is then used in conjunction with this system to effect stabilization against horizontal displacements and to provide centering forces to overcome centrifugal forces when the vehicle is traversing curved sections of a track or when any other transient horizontal force is present. In some proposed embodiments, the Inductrack track elements are also employed as the stator of a linear induction-motor drive and braking system.

  11. Inductrack configuration

    DOEpatents

    Post, Richard Freeman

    2003-10-07

    A simple permanent-magnet-excited maglev geometry provides levitation forces and is stable against vertical displacements from equilibrium but is unstable against horizontal displacements. An Inductrack system is then used in conjunction with this system to effect stabilization against horizontal displacements and to provide centering forces to overcome centrifugal forces when the vehicle is traversing curved sections of a track or when any other transient horizontal force is present. In some proposed embodiments, the Inductrack track elements are also employed as the stator of a linear induction-motor drive and braking system.

  12. TIGER: Development of Thermal Gradient Compensation Algorithms and Techniques

    NASA Technical Reports Server (NTRS)

    Hereford, James; Parker, Peter A.; Rhew, Ray D.

    2004-01-01

    In a wind tunnel facility, the direct measurement of forces and moments induced on the model are performed by a force measurement balance. The measurement balance is a precision-machined device that has strain gages at strategic locations to measure the strain (i.e., deformations) due to applied forces and moments. The strain gages convert the strain (and hence the applied force) to an electrical voltage that is measured by external instruments. To address the problem of thermal gradients on the force measurement balance NASA-LaRC has initiated a research program called TIGER - Thermally-Induced Gradients Effects Research. The ultimate goals of the TIGER program are to: (a) understand the physics of the thermally-induced strain and its subsequent impact on load measurements and (b) develop a robust thermal gradient compensation technique. This paper will discuss the impact of thermal gradients on force measurement balances, specific aspects of the TIGER program (the design of a special-purpose balance, data acquisition and data analysis challenges), and give an overall summary.

  13. A comparison of methods for computing the sigma-coordinate pressure gradient force for flow over sloped terrain in a hybrid theta-sigma model

    NASA Technical Reports Server (NTRS)

    Johnson, D. R.; Uccellini, L. W.

    1983-01-01

    In connection with the employment of the sigma coordinates introduced by Phillips (1957), problems can arise regarding an accurate finite-difference computation of the pressure gradient force. Over steeply sloped terrain, the calculation of the sigma-coordinate pressure gradient force involves computing the difference between two large terms of opposite sign which results in large truncation error. To reduce the truncation error, several finite-difference methods have been designed and implemented. The present investigation has the objective to provide another method of computing the sigma-coordinate pressure gradient force. Phillips' method is applied for the elimination of a hydrostatic component to a flux formulation. The new technique is compared with four other methods for computing the pressure gradient force. The work is motivated by the desire to use an isentropic and sigma-coordinate hybrid model for experiments designed to study flow near mountainous terrain.

  14. Measuring the ability of military aircrews to adapt to perceived stressors when undergoing centrifuge training.

    PubMed

    Wang, Jenhung; Lin, Pei-Chun; Li, Shih-Chin

    2014-01-01

    This study assessed the ability of military aircrews to adapt to stressors when undergoing centrifuge training and determined what equipment items caused perceived stress and needed to be upgraded. We used questionnaires and the Rasch model to measure aircrew personnel's ability to adapt to centrifuge training. The measurement items were ranked by 611 military aircrew personnel. Analytical results indicated that the majority of the stress perceived by aircrew personnel resulted from the lightproof cockpit without outer reference. This study prioritized the equipment requiring updating as the lightproof cockpit design, the dim lighting of the cockpit, and the pedal design. A significant difference was found between pilot and non-pilot subjects' stress from the pedal design; and considerable association was discernible between the seat angle design and flight hours accrued. The study results provide aviators, astronauts, and air forces with reliable information as to which equipment items need to be urgently upgraded as their present physiological and psychological effects can affect the effectiveness of centrifuge training.

  15. Attack on centrifugal costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murray, P.F.

    1986-03-01

    The Monsanto Chocolate Bayou plant has had an aggressive and successful energy conservation program. The combined efforts have resulted in a 80% reduction in unit energy consumption compared to 1972. The approach of using system audits to optimize fluid systems was developed. Since most of the fluid movers are centrifugal, the name Centrifugal Savings Task Force was adopted. There are three tools that are particularly valuable in optimizing fluid systems. First, a working level understanding of the Affinity Laws seems a must. In addition, the performance curves for the fluid movers is needed. The last need is accurate system fieldmore » data. Systems effectively managed at the Chocolate Bayou plant were process air improvement, feed-water pressure reduction, combustion air blower turbine speed control, and cooling tower pressure reduction. Optimization of centrifugal systems is an often-overlooked opportunity for energy savings. The basic guidelines are to move only the fluid needed, and move it at as low a pressure as possible.« less

  16. Plasma Centrifuge Heat Engine - a Route to Non-thermal p- 11 B Fusion

    NASA Astrophysics Data System (ADS)

    Barnes, D. C.

    2007-06-01

    An invention [US Patent and Trademark Office App. Nos. 60/596567 (2005) and 60/766791 (2006)] combines centrifugal and dipole confinement, with recent oscillating plasma theory. The plasma undergoes compression/expansion (C/E), parallel to B by centrifugal force and perpendicular to B by B variation, providing a thermal cycle which recovers most (>95%) of heating as mechanical energy. This gives a "Q-amplifier" for beam-target systems. Centrifugally confined Boron plasma undergoes C/E by slow, cross-B interchange activity. Parallel and perpendicular C/E are matched by the rotation profile which arises naturally. Hot plasma is heated and cold plasma is cooled. Beam-target fusion reactions occur in the hot plasma region and expansion returns most of the heat energy as rotation energy. Rotation energy, in turn, produces waves which drive protons to an energy near the fusion peak cross section. A possible machine, including the arrangement of magnets and HV, is described.

  17. Comparison of gradual and rapid onset runs in a short-arm centrifugation

    NASA Astrophysics Data System (ADS)

    Miyamoto, A.; Saga, K.; Kinoue, T.; Nakazato, T.; Hirayanagi, K.; Yajima, K.; Hayashi, S.; Matsumoto, S.

    A gradual onset run (GOR) in a short-arm centrifugation was performed on ten healthy students. The centrifuge had a 1.8 m radius, and the subjects sat on a chair in a cabin. The Gz force increased to 2.2 Gz at 0.1 °/sec 2 for 32 min. and the same Gz-level was maintained for 20 min. Three out of ten subjects completed the whole protocol; the load on the others was terminated because of symptoms or increased heart rate. There were few symptoms such as vertigo, that was a common problem with a rapid onset run (ROR) in former experiments, due to the short-arm centrifugation. The changes of the flicker test after the load were much less in the GOR protocol than in the ROR protocol, even in the terminated group. GOR seemed preferable to ROR in preventing vertigo even though it took longer to reach the necessary G load.

  18. Leishmania amazonensis chemotaxis under glucose gradient studied by the strength and directionality of forces measured with optical tweezers

    NASA Astrophysics Data System (ADS)

    de Ysasa Pozzo, Liliana; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz Carlos; Ayres, Diana Copi; Giorgio, Selma; Cesar, Carlos Lenz

    2007-02-01

    Chemotaxis is the mechanism microorganisms use to sense the environment surrounding them and to direct their movement towards attractive, or away from the repellent, chemicals. The biochemical sensing is almost the only way for communication between unicellular organisms. Prokaryote and Eukaryote chemotaxis has been mechanically studied mainly by observing the directionality and timing of the microorganisms movements subjected to a chemical gradient, but not through the directionality and strength of the forces it generates. To observe the vector force of microorganisms under a chemical gradient we developed a system composed of two large chambers connected by a tiny duct capable to keep the chemical gradient constant for more than ten hours. We also used the displacements of a microsphere trapped in an Optical Tweezers as the force transducer to measure the direction and the strength of the propulsion forces of flagellum of the microorganism under several gradient conditions. A 9μm diameter microsphere particle was trapped with a Nd:YAG laser and its movement was measured through the light scattered focused on a quadrant detector. We observed the behavior of the protozoa Leishmania amazonensis (eukaryote) under several glucose gradients. This protozoa senses the gradient around it by swimming in circles for three to five times following by tumbling, and not by the typical straight swimming/tumbling of bacteria. Our results also suggest that force direction and strength are also used to control its movement, not only the timing of swimming/tumbling, because we observed a higher force strength clearly directed towards the glucose gradient.

  19. METAL PRODUCTION AND CASTING

    DOEpatents

    Magel, T.T.

    1958-03-01

    This patent covers a method and apparatus for collecting the molten metal produced by high temperature metal salt reduction. It consists essentially of subjecting the reaction vessel to centrifugal force in order to force the liberatcd molten metal into a coherent molten mass, and allowing it to solidify there. The apparatus is particularly suitable for use with small quantities of rare metals.

  20. Apparatus for high speed rotation of electrically operated devices

    DOEpatents

    Williams, Keith E.; Rogus, Arnold J.

    1976-10-26

    Most high speed centrifuges employ a relatively small diameter elongate flexible drive shaft, sometimes called a "quill" shaft. These relatively slender shafts are flexible to absorb vibration as the assembly passes through speeds of resonance and to permit re-alignment of the axis of rotation of the shaft and the rotor driven thereby in the event the center of mass of the rotor and shaft assembly is displaced from the nominal axis of the rotation. To use such an apparatus for testing electrical devices and components, electrical conductors for wires are passed from a slip ring assembly located at an end of the quill shaft remote from the rotor and longitudinally alongside the quill shaft to the electrical device mounted on the rotor. The longitudinally extending conductors are supported against the radially outward directed centrifugal forces by a plurality of strong, self-lubricating, slightly compressible wafers or washers co-axially stacked on the slender shaft and provided with radially offset longitudinally aligned openings to support the longitudinally extending conductors. The conductors are supported against the centrifugal forces and thus protected from rupture or other damage without restricting or constraining the essential flexure or bending of the drive shaft.

  1. Development of a prototype magnetically suspended rotor ventricular assist device.

    PubMed

    Bearnson, G B; Maslen, E H; Olsen, D B; Allaire, P E; Khanwilkar, P S; Long, J W; Kim, H C

    1996-01-01

    A continuous flow centrifugal blood pump with magnetically suspended impeller has been designed, constructed, and tested. The system can be functionally divided into three subsystem designs: 1) centrifugal pump and flow paths, 2) magnetic bearings, and 3) brushless DC motor. The centrifugal pump is a Francis vane type design with a designed operating point of 6 L/min flow and 100 mmHg pressure rise at 2,300 RPM. Peak hydraulic efficiency is over 50%. The magnetic bearing system is an all active design with five axes of control. Rotor position sensors were developed as part of the system to provide feedback to a proportional-integral-derivative controller. The motor is a sensorless brushless DC motor. Back electromotive force voltage generated by the motor is used to provide commutation for the motor. No slots are employed in the motor design in order to reduce the radial force that the bearings must generate. Tests pumping blood in vitro were very encouraging; an index of hemolysis of 0.0086 +/- 0.0012 was measured. Further design refinement is needed to reduce power dissipation and size of the device. The concept of using magnetic bearings in a blood pump shows promise in a long-term implantable blood pump.

  2. The Purification and Concentration of Hog Cholera Virus*

    PubMed Central

    Cunliffe, H. R.; Rebers, P. A.

    1968-01-01

    Partial purification of hog cholera virus (HCV) using a simple batch-type chromatographic procedure with magnetic ferric oxide (MFO) is described. Infectious HCV was adsorbed from isotonic solutions to MFO and was eluted under conditions of low ionic strength and high pH. Aqueous solutions of 0.01 M sodium cyanide or 0.0003 M ammonium hydroxide effectively dissociated MFO-HCV complexes. The data indicate that 50 to 100% of the original HCV infectivity was recovered concomitant with a 90 to 95% reduction of extraneous organic nitrogen. MFO-purified HCV was concentrated by density gradient type centrifugations in buffered solutions of cesium chloride and sucrose. Prolonged isodensity centrifugations of concentrated MFO-purified HCV indicated a buoyant density of 1.14 to 1.15 gm/ml for the strain of virus used. PMID:15846899

  3. Cardiovascular responses of snakes to hypergravity

    NASA Technical Reports Server (NTRS)

    Lillywhite, H. B.; Ballard, R. E.; Hargens, A. R.; Rosenberg, H. I.

    1997-01-01

    Snakes have provided useful vertebrate models for understanding circulatory adaptation to gravity, attributable to their elongate body shape and evolutionary diversificaton in terms of ecology and behavior. Recently we have studied cardiovascular responses of snakes to hypergravic acceleration forces produced acutely in the head-to-tail direction (+Gz) on a short-arm centrifuge. Snakes were held in a nearly straight position within a horizontal plastic tube and subjected to a linear force gradient during acceleration. Carotid blood flow provided an integrated measure of cardiovascular performance. Thus, cardiovascular tolerance of snakes to stepwise increments of Gz was measured as the caudal Gz force at which carotid blood flow ceased. Tolerance to increasing Gz varies according to adaptive evolutionary history inferred from the ecology and behavior of species. With respect to data for six species we investigated, multiple regression analysis demonstrates that Gz tolerance correlates with gravitational habitat, independently of body length. Relative to aquatic and non-climbing species, carotid blood flow is better maintained in arboreal or scansorial species, which tolerate hypergravic forces of +2 to +3.5 Gz. Additionally, semi-arboreal rat snakes (Elaphe obsoleta) exhibit plasticity of responses to long-term, intermittent +1.5 Gz stress. Compared to non-acclimated controls, acclimated snakes show greater increases of heart rate during head-up tilt or acceleration, greater sensitivity of arterial pressure to circulating catecholamines, higher blood levels of prostaglandin ratios favorable to maintenance of arterial blood pressure, and medial hypertrophy in major arteries and veins. As in other vertebrates, Gz tolerance of snakes is enhanced by acclimation, high arterial pressure, comparatively large blood volume, and body movements. Vascular studies of snakes suggest the importance to acclimation of local responses involving vascular tissue, in addition to centrally mediated responses to fluid shifts.

  4. Experiences with nonsynchronous forced vibration in centrifugal compressors

    NASA Technical Reports Server (NTRS)

    Smith, D. R.; Wachel, J. C.

    1984-01-01

    The high subsynchronous vibrations which are often forced vibrations caused by flow instabilities, such as stage stall were examined. Modifications to improve the rotor stability by changing the bearings or seals have little effects on the subsynchronous vibrations. Understanding of the differences between forced vibrations and self excited vibrations to properly diagnose the problem and to correct it, is recommended. A list of characteristics of the two types of subsynchronous vibration is presented.

  5. Directional acceleration vector-driven displacement of fluids (DAVD-DOF)

    NASA Technical Reports Server (NTRS)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    2004-01-01

    Centrifugal analyzer and method for staining biological or non-biological samples in microgravity, wherein the method utilizes an increase in weight of a fluid sample as a function of g-load, to overcome cohesive and frictional forces from preventing its movement in a preselected direction. Apparatus is characterized by plural specimen reservoirs and channels in a slide, each channel being of differing cross-section, wherein respective samples are selectively dispensed, from the reservoirs in response to an imposed g-factor, precedent to sample staining. Within the method, one thus employs microscope slides which define channels, each being of a differing cross-section dimension relative to others. In combination therewith, centrifugal slide mounting apparatus controllably imposes g-vectors of differing magnitudes within a defined structure of the centrifuge such as a chip array.

  6. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, Jerald A.

    1997-01-01

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for 1) cleaning, developing or etching, 2) rinsing, and 3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material.

  7. Moving zone Marangoni drying of wet objects using naturally evaporated solvent vapor

    DOEpatents

    Britten, J.A.

    1997-08-26

    A surface tension gradient driven flow (a Marangoni flow) is used to remove the thin film of water remaining on the surface of an object following rinsing. The process passively introduces by natural evaporation and diffusion of minute amounts of alcohol (or other suitable material) vapor in the immediate vicinity of a continuously refreshed meniscus of deionized water or another aqueous-based, nonsurfactant rinsing agent. Used in conjunction with cleaning, developing or wet etching application, rinsing coupled with Marangoni drying provides a single-step process for (1) cleaning, developing or etching, (2) rinsing, and (3) drying objects such as flat substrates or coatings on flat substrates without necessarily using heat, forced air flow, contact wiping, centrifugation or large amounts of flammable solvents. This process is useful in one-step cleaning and drying of large flat optical substrates, one-step developing/rinsing and drying or etching/rinsing/drying of large flat patterned substrates and flat panel displays during lithographic processing, and room-temperature rinsing/drying of other large parts, sheets or continuous rolls of material. 5 figs.

  8. Purification of Giardia muris cysts by velocity sedimentation.

    PubMed Central

    Sauch, J F

    1984-01-01

    Giardia muris cysts were separated from fecal contaminants in primary isolates by unit gravity velocity sedimentation. Crude isolates obtained by centrifugation over 1.0 M sucrose were overlaid onto a Percoll density gradient, 1.01 to 1.03 g/ml. G. muris cysts were well separated from faster-sedimenting fecal debris and slower-sedimenting Spironucleus muris and bacteria in 1.5 h. PMID:6486790

  9. Identification of the Centrifuged Lipoaspirate Fractions Suitable for Postgrafting Survival.

    PubMed

    Qiu, Lihong; Su, Yingjun; Zhang, Dongliang; Song, Yajuan; Liu, Bei; Yu, Zhou; Guo, Shuzhong; Yi, Chenggang

    2016-01-01

    The Coleman centrifugation procedure generates fractions with different adipocyte and progenitor cell densities. This study aimed to identify all fractions that are feasible for implantation. Human lipoaspirates were processed by Coleman centrifugation. The centrifugates were divided arbitrarily into upper, middle, and lower layers. Adipocyte viability, morphology, numbers of stromal vascular fraction cells, and adipose-derived mesenchymal stem cells of each layer were determined. The 12-week volume retention of subcutaneously implanted 0.3-ml lipoasperate of each layer was investigated in an athymic mice model. Most damaged adipocytes were located in the upper layers, whereas the intact adipocytes were distributed in the middle and lower layers. A gradient of stromal vascular fraction cell density was formed in the centrifugates. The implant volume retentions of samples from the upper, middle, and lower layers were 33.44 ± 5.9, 55.11 ± 4.4, and 71.2 ± 5.8 percent, respectively. Furthermore, the middle and lower layers contained significantly more adipose-derived stem cells than did the upper layer. The lower layer contains more viable adipocytes and stromal vascular fraction cells leading to the highest implant volume retention, whereas the most impaired cells are distributed in the upper layer, leading to the least volume retention. Although with a lower stromal vascular fraction content, the middle layer has a substantial number of intact adipocytes that are capable of retaining partial adipose tissue volume after implantation, suggesting that the middle layer may be an alternative fat source when large volumes of fat grafts are needed for transplantation.

  10. Enrichment of reticulocytes from whole blood using aqueous multiphase systems of polymers.

    PubMed

    Kumar, Ashok A; Lim, Caeul; Moreno, Yovany; Mace, Charles R; Syed, Abeer; Van Tyne, Daria; Wirth, Dyann F; Duraisingh, Manoj T; Whitesides, George M

    2015-01-01

    This paper demonstrates the enrichment of reticulocytes by centrifuging whole blood through aqueous multiphase systems (AMPSs)-immiscible phases of solutions of polymers that form step-gradients in density. The interfaces of an AMPS concentrate cells; this concentration facilitates the extraction of blood enriched for reticulocytes. AMPS enrich reticulocytes from blood from both healthy and hemochromatosis donors. Varying the osmolality and density of the phases of AMPS provides different levels of enrichment and yield of reticulocytes. A maximum enrichment of reticulocytemia of 64 ± 3% was obtained from donors with hemochromatosis. When used on peripheral blood from normal donors, AMPS can provide a higher yield of enriched reticulocytes and a higher proportion of reticulocytes expressing CD71 than differential centrifugation followed by centrifugation over Percoll. Blood enriched for reticulocytes by AMPS could be useful for research on malaria. Several species of malaria parasites show a preference to invade young erythrocytes and reticulocytes; this preference complicates in vitro cultivation of these species in human blood. Plasmodium knowlesi malaria parasites invade normal human blood enriched for reticulocytes by AMPSs at a rate 2.2 times greater (P < 0.01) than they invade unenriched blood. Parasite invasion in normal blood enriched by AMPS was 1.8 times greater (P < 0.05) than in blood enriched to a similar reticulocytemia by differential centrifugation followed by centrifugation over Percoll. The enrichment of reticulocytes that are invaded by malaria parasites demonstrates that AMPSs can provide a label-free method to enrich cells for biological research. © 2014 Wiley Periodicals, Inc.

  11. Isolation and characterization of a mucosal triacylglycerol pool undergoing hydrolysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tipton AD IV; Frase, S.; Mansbach, C.M. II

    1989-12-01

    Absorbed and processed mucosal neutral lipid has been shown to be composed of at least two pools of triacylglycerol. One is likely to subserve chylomicron formation, and the other appears to be transported from the intestine via a nonlymphatic route. In the present study, 50 +/- 5% of the mucosal lipid pellets was centrifuged at 75,000 g.min (low-speed pellet (LSP)). Discontinuous sucrose density gradient centrifugation of LSP showed that 61 +/- 7% of the lipid banded at the 0.25-0.86 M sucrose interface. Neutral lipid analysis showed that this subfraction was only 58% triacylglycerol, suggesting it was undergoing hydrolysis. Active lipolyticmore » activity in vitro was found on incubation. The lipase had an alkaline pH optimum (pH 8.5) and persisted despite pancreatic ductular diversion. Lipolysis in vivo in a LSP fraction was shown by infusing (14C)glyceryltrioleate for 3.5 h followed by (3H)glyceryltrioleate for 30 min. Discontinuous sucrose density centrifugation of the LSP followed by an analysis of the lipids at the 0.25-0.86 M sucrose interface showed that 14C-neutral lipids were only 70 +/- 6% triacylglycerol, whereas 3H-neutral lipids were 88 +/- 2% triacylglycerol. 3H entered LSP slowly compared with the floating lipid in the same centrifuge tube. These studies suggest both in vivo and in vitro mucosal lipolysis by a specific, alkaline-active lipase. The turnover rate of LSP is likely to be slow by comparison with neutral lipid floating to the top of the centrifuge tube.« less

  12. Computer-assisted sperm analysis of fresh epididymal cat spermatozoa and the impact of cool storage (4 degrees C) on sperm quality.

    PubMed

    Filliers, M; Rijsselaere, T; Bossaert, P; De Causmaecker, V; Dewulf, J; Pope, C E; Van Soom, A

    2008-12-01

    Epididymal cat sperm is commonly used for in vitro fertilization. Because of the high variability in preparation protocols and methods of evaluation, sperm quality may vary considerably between experiments and laboratories. The aims of the present study were (1) to describe an epididymal sperm preparation protocol to produce clean, highly motile samples using density gradient centrifugation, (2) to provide reference values of computer-assisted semen analysis (CASA) parameters of fresh epididymal cat sperm after density gradient centrifugation and (3) to investigate the effect of cool storage on various spermatozoa characteristics. After slicing the epididymides, viable and motile sperm cells were isolated using Percoll centrifugation. Sperm motility parameters were subsequently assessed using CASA in experiment 1. In experiment 2, fresh (day 0) sperm samples were evaluated for motility parameters (HTR) and stained for assessment of acrosomal status (FITC-PSA), morphology (eosin/nigrosin (E/N)), membrane integrity (E/N and SYBR((R))14-PI) and DNA fragmentation (TUNEL). After addition of a Tris-glucose-citrate diluent containing 20% egg yolk, samples were cooled to 4 degrees C and reassessed on d1, d3, d5, d7 and d10. Cool storage impaired most motility and velocity parameters: MOT, PMOT, VAP, VSL, VCL, BCF, RAPID and the percentage of normal spermatozoa showed a decrease over time (P<0.05) as compared to fresh samples. In contrast, STR, ALH, membrane integrity, DNA fragmentation and the percentage of acrosome intact spermatozoa were not affected by cool storage. However, the influence of cool storage of cat spermatozoa on subsequent in vitro embryo development and quality after IVF requires further investigation.

  13. The three-dimensional model for helical columns on type-J synchronous counter-current chromatography.

    PubMed

    Guan, Y H; van den Heuvel, Remco

    2011-08-05

    Unlike the existing 2-D pseudo-ring model for helical columns undergoing synchronous type-J planetary motion of counter-current chromatograph (CCC), the 3-D "helix" model developed in this work shows that there is a second normal force (i.e. the binormal force) applied virtually in the axial direction of the helical column. This force alternates in the two opposite directions and intensifies phase mixing with increasing the helix angle. On the contrary, the 2-D spiral column operated on the same CCC device lacks this third-dimensional mixing force. The (principal) normal force quantified by this "helix" model has been the same as that by the pseudo-ring model. With β>0.25, this normal centrifugal force has been one-directional and fluctuates cyclically. Different to the spiral column, this "helix" model shows that the centrifugal force (i.e. the hydrostatic force) does not contribute to stationary phase retention in the helical column. Between the popular helical columns and the emerging spiral columns for type-J synchronous CCC, this work has thus illustrated that the former is associated with better phase mixing yet poor retention for the stationary phase whereas the latter has potential for better retention for the stationary phase yet poor phase mixing. The methodology developed in this work may be regarded as a new platform for designing optimised CCC columns for analytical and engineering applications. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Coronal Jet Collimation by Nonlinear Induced Flows

    NASA Astrophysics Data System (ADS)

    Vasheghani Farahani, S.; Hejazi, S. M.

    2017-08-01

    Our objective is to study the collimation of solar jets by nonlinear forces corresponding to torsional Alfvén waves together with external forces. We consider a straight, initially non-rotating, untwisted magnetic cylinder embedded in a plasma with a straight magnetic field, where a shear between the internal and external flows exists. By implementing magnetohydrodynamic theory and taking into account the second-order thin flux tube approximation, the balance between the internal nonlinear forces is visualized. The nonlinear differential equation containing the ponderomotive, magnetic tension, and centrifugal forces in the presence of the shear flow is obtained. The solution presents the scale of influence of the propagating torsional Alfvén wave on compressive perturbations. Explicit expressions for the compressive perturbations caused by the forces connected to the torsional Alfvén wave show that, in the presence of a shear flow, the magnetic tension and centrifugal forces do not cancel each other’s effects as they did in its absence. This shear flow plays in favor of the magnetic tension force, resulting in a more efficient collimation. Regarding the ponderomotive force, the shear flow has no effect. The phase relations highlight the interplay of the shear flow and the plasma-β. As the shear flow and plasma-β increase, compressive perturbation amplitudes emerge. We conclude that the jet collimation due to the torsional Alfvén wave highly depends on the location of the jet. The shear flow tightens the collimation as the jet elevates up to the solar corona.

  15. Commercial spaceflight participant G-force tolerance during centrifuge-simulated suborbital flight.

    PubMed

    Blue, Rebecca S; Riccitello, Jon M; Tizard, Julia; Hamilton, Richard J; Vanderploeg, James M

    2012-10-01

    Medical knowledge of the human body in microgravity and hypergravity is based upon studies of healthy individuals well-conditioned for such environments. Little data exist regarding the effects of spaceflight on untrained commercial passengers. We examined the responses of potential spaceflight participants (SFP) to centrifuge G-force exposure. There were 77 individuals (65 men, 12 women), 22-88 yr old, who underwent 6 centrifuge runs over 48 h. Day 1 consisted of two +Gz runs (peak = 3.5+Gz, run 2) and two +Gx runs (peak = 6.0+Gx, run 4). Day 2 consisted of two runs approximating a suborbital spaceflight profile. Data included blood pressure, electrocardiogram, and postrun questionnaires regarding motion sickness, disorientation, greyout, and other symptoms. Of the 77 participants, average age was 50.4 +/- 12.7 yr. Average heart rate (HR) varied by sex and direction of G-exposure (+Gz: F 150 +/- 19, M 123 +/- 27; +Gx: F 135 +/- 30, M 110 +/- 27). Age and peak HR were inversely related (HR < 120 bpm: 60.2 +/- 12.2 yr, HR > 120: 47.1 +/- 10.9 yr). HR during peak G-exposure for the final run was associated with post-run imbalance (no imbalance: HR 126 +/- 26, imbalance: HR 145 +/- 21); no other significant hemodynamic change, sex, or age variation was associated with imbalance. Age and greyout were inversely associated; there was no association between greyout and vital sign change, sex, or G-force magnitude. Baseline/pretrial mean arterial pressure (MAP) was not associated with any symptoms. The results suggest that most individuals with well-controlled medical conditions can withstand acceleration forces involved in launch/landing profiles of commercial spaceflight vehicles. Further investigation will help refine which conditions present significant risk during suborbital flight and beyond.

  16. Centrifugation assay for measuring adhesion of serially passaged bovine chondrocytes to polystyrene surfaces.

    PubMed

    Kaplan, David S; Hitchins, Victoria M; Vegella, Thomas J; Malinauskas, Richard A; Ferlin, Kimberly M; Fisher, John P; Frondoza, Carmelita G

    2012-07-01

    A major obstacle in chondrocyte-based therapy for cartilage repair is the limited availability of cells that maintain their original phenotype. Propagation of chondrocytes as monolayer cultures on polystyrene surfaces is used extensively for amplifying cell numbers. However, chondrocytes undergo a phenotypic shift when propagated in this manner and display characteristics of more adherent fibroblastic cells. Little information is available about the effect of this phenotypic shift on cellular adhesion properties. We evaluated changes in adhesion property as bovine chondrocytes were serially propagated up to five passages in monolayer culture using a centrifugation cell adhesion assay, which was based on counting of cells before and after being exposed to centrifugal dislodgement forces of 120 and 350 g. Chondrocytes proliferated well in a monolayer culture with doubling times of 2-3 days, but they appeared more fibroblastic and exhibited elongated cell morphology with continued passage. The centrifugation cell adhesion assay showed that chondrocytes became more adhesive with passage as the percentage of adherent cells after centrifugation increased and was not statistically different from the adhesion of the fibroblast cell line, L929, starting at passage 3. This increased adhesiveness correlated with a shift to a fibroblastic morphology and increased collagen I mRNA expression starting at passage 2. Our findings indicate that the centrifugation cell adhesion assay may serve as a reproducible tool to track alterations in chondrocyte phenotype during their extended propagation in culture.

  17. Uplifting behavior of shallow buried pipe in liquefiable soil by dynamic centrifuge test.

    PubMed

    Huang, Bo; Liu, Jingwen; Lin, Peng; Ling, Daosheng

    2014-01-01

    Underground pipelines are widely applied in the so-called lifeline engineerings. It shows according to seismic surveys that the damage from soil liquefaction to underground pipelines was the most serious, whose failures were mainly in the form of pipeline uplifting. In the present study, dynamic centrifuge model tests were conducted to study the uplifting behaviors of shallow-buried pipeline subjected to seismic vibration in liquefied sites. The uplifting mechanism was discussed through the responses of the pore water pressure and earth pressure around the pipeline. Additionally, the analysis of force, which the pipeline was subjected to before and during vibration, was introduced and proved to be reasonable by the comparison of the measured and the calculated results. The uplifting behavior of pipe is the combination effects of multiple forces, and is highly dependent on the excess pore pressure.

  18. Fluid/structure interactions in turbomachinery; Proceedings of the Winter Annual Meeting, Washington, DC, November 15-20, 1981

    NASA Astrophysics Data System (ADS)

    Thompson, W. E.

    The behavior of fluids, gas, and mechanical components in turbomachinery is investigated. The prediction of aerodynamically induced vibrations in turbomachinery blading is described, and the measurement of aerodynamic work during fan flutter and the calculation of the vibration of an elastically mounted cylinder from experimental forced oscillation data are discussed. Attention is given to tangential vibration of integral turbine blades due to partial admission and to the effects of an annular fluid on the critical speed of a rotating shaft. The analysis of rotordynamic coefficients for convergent-tapered annular seals is examined and results of studies of fluid forces on a whirling centrifugal impeller in a vaneless diffuser are reported. Finally, the potential interaction between a centrifugal impeller and a vaned diffuser and the excitation of compressor/duct are examined.

  19. The centrifugal and centripetal force influence on spatial competition of agricultural land in Bandung Metropolitan Region

    NASA Astrophysics Data System (ADS)

    Sadewo, E.

    2017-06-01

    Agricultural activity has suffered a massive land functional shift caused by market mechanism in Bandung metropolitan region (BMR). We argue that the existence of agricultural land in urban spatial structure is the result of interaction between centrifugal and centripetal force on spatial competition. This research aims to explore how several recognized centrifugal and centripetal force influence to the existence of agricultural land in BMR land development. The analysis using multivariate regression indicates that there exists spatial competition between population density and degree of urbanization with agricultural land areas. Its extended spatial regression model suggested that neighboring situation plays an important role to preserve agricultural land areas existences in BMR. Meanwhile, the influence of distance between the location of the city center and employment opportunities is found to be insignificant in the spatial competition. It is opposed to the theory of von Thünen and monocentric model in general. One of the possible explanation of such condition is that the assumption of centrality does not met. In addition, the agricultural land density decay in the southern parts of the area was related to its geographical conditions as protected areas or unfavorable for farming activity. It is suggested that BMR was in the early phase of polycentric development. Hence, better policies that lead redirected development to the southern part of the region is needed as well as population control and regulation of land use.

  20. A technique for production of nanocrystalline cellulose with a narrow size distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Wen; Holbery, James D.; Li, Kaichang

    2009-02-01

    Nanocrystalline cellulose (NCC) was prepared by sulfuric acid hydrolysis of microcrystalline cellulose. A differential centrifugation technique was studied to obtain NCC whiskers with a narrow size distribution. It was shown that the volume of NCC in different fractions had an inverse relationship with relative centrifugal force (RCF). The length of NCC whiskers was also fractionized by differential RCF. The aspect ratio of NCC in different fractions had a relatively narrow range. This technique provides an easy way of producing NCC whiskers with a narrow size distribution.

  1. Subcellular fractionation by zonal centrifugation of glucose-repressed anaerobically grown Saccharomyces carlsbergensis

    PubMed Central

    Cartledge, T. G.; Lloyd, D.

    1972-01-01

    1. Homogenates were prepared from sphaeroplasts of anaerobically grown, glucoserepressed Saccharomyces carlsbergensis, and the distributions of marker enzymes investigated after zonal centrifugation on sucrose gradients containing 2mm-MgCl2. 2. These homogenates contained no detectable cytochrome c oxidase, succinate–cytochrome c oxidoreductase, succinate–ferricyanide oxidoreductase, l(+)-lactate–cytochrome c oxidoreductase or catalase. Cytochromes a+a3 and c were not detected. 3. Zonal centrifugation of whole homogenates indicated complex density distributions of the sedimentable portions of NADH– and NADPH–cytochrome c oxidoreductases, adenosine triphosphatases (ATPases), adenosine pyrophosphatase (ADPase), pyrophosphatase and acid p-nitrophenyl phosphatase. Several different ATPases were distinguished on the basis of their sensitivities to oligomycin and ouabain. 4. Differential centrifugation of whole homogenates at 105g-min left 80–90% of the protein, dithionite-reducible cytochrome b, acid hydrolases and pyrophosphatase in a supernatant (S1) together with 65 and 56% of the NADH– and NADPH–cytochrome c oxidoreductases respectively, 25% of the ATPases and 71% of the adenosine monophosphatase. 5. Further analysis of supernatant S1 revealed the presence of a class of small particles containing NADPH–cytochrome c oxidoreductases and ATPases. 6. At least four different populations of large particles were distinguished. 7. Electron microscopy indicated that one of these corresponded to `promitochondria' as described by other workers. ImagesPLATE 1PLATE 2PLATE 3 PMID:4405573

  2. Effects of artificial gravity on the cardiovascular system: Computational approach

    NASA Astrophysics Data System (ADS)

    Diaz Artiles, Ana; Heldt, Thomas; Young, Laurence R.

    2016-09-01

    Artificial gravity has been suggested as a multisystem countermeasure against the negative effects of weightlessness. However, many questions regarding the appropriate configuration are still unanswered, including optimal g-level, angular velocity, gravity gradient, and exercise protocol. Mathematical models can provide unique insight into these questions, particularly when experimental data is very expensive or difficult to obtain. In this research effort, a cardiovascular lumped-parameter model is developed to simulate the short-term transient hemodynamic response to artificial gravity exposure combined with ergometer exercise, using a bicycle mounted on a short-radius centrifuge. The model is thoroughly described and preliminary simulations are conducted to show the model capabilities and potential applications. The model consists of 21 compartments (including systemic circulation, pulmonary circulation, and a cardiac model), and it also includes the rapid cardiovascular control systems (arterial baroreflex and cardiopulmonary reflex). In addition, the pressure gradient resulting from short-radius centrifugation is captured in the model using hydrostatic pressure sources located at each compartment. The model also includes the cardiovascular effects resulting from exercise such as the muscle pump effect. An initial set of artificial gravity simulations were implemented using the Massachusetts Institute of Technology (MIT) Compact-Radius Centrifuge (CRC) configuration. Three centripetal acceleration (artificial gravity) levels were chosen: 1 g, 1.2 g, and 1.4 g, referenced to the subject's feet. Each simulation lasted 15.5 minutes and included a baseline period, the spin-up process, the ergometer exercise period (5 minutes of ergometer exercise at 30 W with a simulated pedal cadence of 60 RPM), and the spin-down process. Results showed that the cardiovascular model is able to predict the cardiovascular dynamics during gravity changes, as well as the expected steady-state cardiovascular behavior during sustained artificial gravity and exercise. Further validation of the model was performed using experimental data from the combined exercise and artificial gravity experiments conducted on the MIT CRC, and these results will be presented separately in future publications. This unique computational framework can be used to simulate a variety of centrifuge configuration and exercise intensities to improve understanding and inform decisions about future implementation of artificial gravity in space.

  3. Evaluation and use of a diffusion-controlled sampler for determining chemical and dissolved oxygen gradients at the sediment-water interface

    USGS Publications Warehouse

    Simon, N.S.; Kennedy, M.M.; Massoni, C.S.

    1985-01-01

    Field and laboratory evaluations were made of a simple, inexpensive diffusion-controlled sampler with ports on two sides at each interval which incorporates 0.2-??m polycarbonate membrane to filter samples in situ. Monovalent and divalent ions reached 90% of equilibrium between sampler contents and the external solution within 3 and 6 hours, respectively. Sediment interstitial water chemical gradients to depths of tens of centimeters were obtained within several days after placement. Gradients were consistent with those determined from interstitial water obtained by centrifugation of adjacent sediment. Ten milliliter sample volumes were collected at 1-cm intervals to determine chemical gradients and dissolved oxygen profiles at depth and at the interface between the sediment and water column. The flux of dissolved species, including oxygen, across the sediment-water interface can be assessed more accurately using this sampler than by using data collected from benthic cores. ?? 1985 Dr W. Junk Publishers.

  4. Field Demonstration of a Centrifugal Ultra High Pressure (UHP) P-19

    DTIC Science & Technology

    2010-03-01

    States Air Force  Tyndall Air Force Base, FL 32403-5323 DISTRIBUTION A: Approved for public release; distribution unlimited. NOTICE AND SIGNATURE...PUBLICATION IN ACCORDANCE WITH ASSIGNED DISTRIBUTION STATEMENT. ___//SIGNATURE//______________________ ___//SIGNATURE//______________________ R...PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 6. AUTHOR(S) 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8

  5. Proposal of Unique Process Pump with Floating Type Centrifugal Impeller (Preliminarily Report : Axial Thrust of Impeller with Driving Shaft)

    NASA Astrophysics Data System (ADS)

    Kawashima, Ryunosuke; Kanemoto, Toshiaki; Sakamoto, Kengo; Uno, Mitsuo

    2010-06-01

    The authors have proposed the unique centrifugal pump, in which the impeller dose not have the driving shaft but is driven by the magnetic induction, namely Lorentz force, without the stay. Then, the rotating posture of the impeller is not stable, just like UFO. To make the rotating posture of the impeller stable irrespective of the operating condition, the pressure in the impeller casing was investigated experimentally while the impeller rotates at the steady state, as the preliminarily stage. The pressure, as well known, fluctuates periodically in response to the blade number. Besides, the pressure on the impeller shrouds decreases with the increase of the gap between the front shroud and the suction cover where the water leaks to the suction pipe, and is distorted in the peripheral direction. Such pressure conditions contribute directly to the hydraulic force acting on the impeller. The unstable behaviors of the impeller are induced from the above hydraulic forces, which change unsteadily in the radial and the peripheral directions in the impeller casing. The forces are affected by not only the operating condition but also the rotating posture of the impeller.

  6. The force balance of sea ice in a numerical model of the Arctic Ocean

    NASA Astrophysics Data System (ADS)

    Steele, Michael; Zhang, Jinlun; Rothrock, Drew; Stern, Harry

    1997-09-01

    The balance of forces in the sea ice model of Hibler [1979] is examined. The model predicts that internal stress gradients are an important force in much of the Arctic Ocean except in summer, when they are significant only off the northern coasts of Greenland and the Canadian Archipelago. A partition of the internal stress gradient between the pressure gradient and the viscous terms reveals that both are significant, although they operate on very different timescales. The acceleration term is generally negligible, while the sum of Coriolis plus sea surface tilt is small. Thus the seasonal average force balance in fall, winter, and spring is mostly between three terms of roughly equal magnitudes: air drag, water drag, and internal stress gradients. This is also true for the monthly average force balance. However, we find that there is a transition around the weekly timescale and that on a daily basis the force balance at a particular location and time is often between only two terms: either between air drag and water drag or between air drag and internal stress gradients. The model is in agreement with the observations of Thorndike and Colony [1982] in that the correlation between geostrophic wind forcing and the model's ice velocity field is high. This result is discussed in the context of the force balance; we show that the presence of significant internal stress gradients does not preclude high wind-ice correlation. A breakdown of the internal stress gradient into component parts reveals that the shear viscous force is far from negligible, which casts strong doubt on the theoretical validity of the cavitating fluid approximation (in which this component is neglected). Finally, the role of ice pressure is examined by varying the parameter P*. We find a strong sensitivity in terms of the force balance, as well as ice thickness and velocity.

  7. Subject anxiety and psychological considerations for centrifuge-simulated suborbital spaceflight.

    PubMed

    Mulcahy, Robert A; Blue, Rebecca S; Vardiman, Johnené L; Mathers, Charles H; Castleberry, Tarah L; Vanderploeg, James M

    2014-08-01

    Anxiety and psychological concerns may pose a challenge to future commercial spaceflight. To help identify potential measures of anxiousness and indicators of flight-related stress, the psychiatric histories and anxiousness responses of volunteers exposed to G forces in centrifuge-simulated spaceflight acceleration profiles were examined. Over 2 d, 86 individuals (63 men, 23 women), 20-78 yr old, underwent up to 7 centrifuge runs. Day 1 consisted of two +G(z) runs (peak = +3.5 G(z)) and two +Gx runs (peak = +6.0 G(x)). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +G(x) and +G(z)). Hemodynamic data were collected during the profiles. Subjects completed a retrospective self-report anxiety questionnaire. Medical monitors identified individuals exhibiting varying degrees of anxiousness during centrifuge exposure, medical histories of psychiatric disease, and other potential indicators of psychological intolerance of spaceflight. The retrospective survey identified 18 individuals self-reporting anxiousness, commonly related to unfamiliarity with centrifuge acceleration and concerns regarding medical history. There were 12 individuals (5 men, 7 women, average age 46.2 yr) who were observed to have anxiety that interfered with their ability to complete training; of these, 4 reported anxiousness on their questionnaire and 9 ultimately completed the centrifuge profiles. Psychiatric history was not significantly associated with anxious symptoms. Anxiety is likely to be a relevant and potentially disabling problem for commercial spaceflight participants; however, positive psychiatric history and self-reported symptoms did not predict anxiety during centrifuge performance. Symptoms of anxiousness can often be ameliorated through training and coaching. Even highly anxious individuals are likely capable of tolerating commercial spaceflight.

  8. Geotechnical centrifuge under construction

    NASA Astrophysics Data System (ADS)

    Richman, Barbara T.

    Modifications are underway at the National Aeronautics and Space Administration (NASA) Ames Research Center in California to transform a centrifuge used in the Apollo space program to the largest geotechnical centrifuge in the free world. The centrifuge, to be finished in August and opened next January, following check out and tuning, will enable geoscientists to model stratigraphic features down to 275 m below the earth's surface. Scientists will be able to model processes that are coupled with body force loading, including earthquake response of earth structures and soil structure interaction; rubbled-bed behavior during in situ coal gasification or in oil shale in situ retorts; behavior of frozen soil; frost heave; behavior of offshore structures; wave-seabed interactions; explosive cratering; and blast-induced liquefaction.The centrifuge will have a load capacity of 900-g-tons (short); that is, it will be able to carry a net soil load of 3 short tons to a centripetal acceleration of 300 times the acceleration caused by gravity. Modified for a total cost of $2.4 million, the centrifuge will have an arm with a 7.6-m radius and a swinging platform or bucket at its end that will be able to carry a payload container measuring 2.1×2.1 m. An additional future input of $500,000 would enable the purchase of a larger bucket that could accommodate a load of up to 20 tons, according to Charles Babendreier, program director for geotechnical engineering at the National Science Foundation. Additional cooling for the motor would also be required. The centrifuge has the capability of accelerating the 20-ton load to 100 g.

  9. Detailed Studies on the Structure and Dynamics of Reacting Dusty Flows at Normal and Microgravity

    NASA Technical Reports Server (NTRS)

    Andac, M. Gurhan; Cracchiola, Brad; Egolfopoulos, Fokion N.; Campbell, Charles S.

    1999-01-01

    Dusty reacting flows are of particular interest for a wide range of applications. Inert particles can alter the flammability and extinction limits of a combustible mixture. Reacting particles can release substantial amount of heat and can be used either for power generation or propulsion. Accumulation of combustible particles in air can result in explosions which, for example, can occur in grain elevators, during lumber milling and in mine galleries. Furthermore, inert particles are used as flow velocity markers in reacting flows, and their velocity is measured by non-intrusive laser diagnostic techniques. Despite their importance, dusty reacting flows have been less studied and understood compared to gas phase as well as sprays. The addition of solid particles in a flowing gas stream can lead to strong couplings between the two phases, which can be of dynamic, thermal, and chemical nature. The dynamic coupling between the two phases is caused by the inertia that causes the phases to move with different velocities. Furthermore, gravitational, thermophoretic, photophoretic, electrophoretic, diffusiophoretic, centrifugal, and magnetic forces can be exerted on the particles. In general, magnetic, electrophoretic, centrifugal, photophoretic, and diffusiophoretic can be neglected. On the other hand, thermophoretic forces, caused by steep temperature gradients, can be important. The gravitational forces are almost always present and can affect the dynamic response of large particles. Understanding and quantifying the chemical coupling between two phases is a challenging task. However, all reacting particles begin this process as inert particles, and they must be heated before they participate in the combustion process. Thus, one must first understand the interactions of inert particles in a combustion environment. The in-detail understanding of the dynamics and structure of dusty flows can be only advanced by considering simple flow geometries such as the opposed-jet, stagnation-type. In such configurations the imposed strain rate is well characterized, and the in-depth understanding of the details of the physico-chemical processes can be systematically obtained. A number of computational and experimental studies on spray and particle flows have been conducted in stagnation-type configurations. Numerically, the need for a hybrid Eulerian-Lagrangian approach has been identified by Continillo and Sirignano, and the use of such approach has allowed for the prediction of the phenomenon of droplet flow reversal. Gomez and Rosner have conducted a detailed study on the particle response in the opposed-jet configuration, and the particle thermophoretic diffusivities were determined experimentally. Sung, Law and co-workers have conducted numerical studies on the effect of strain rate and temperature gradients on the dynamics of inert particles, as a way of understanding potential errors in experimental LDV data that may arise from thermophoretic forces. This investigation is a combined experimental and numerical study on the details of reacting dusty flows. The specific tasks are: (1) Experimental determination of laminar flame speeds, and extinction strain rates of dusty flows at normal- and micro-gravity as functions of the particle type, particle initial diameter, particle initial number density, and gas phase chemical composition; (2) Detailed numerical simulation of the experiments. Results are compared with experiments and the adequacy of theoretical models is assessed; and (3) Provision of enhanced insight into the thermo-chemical coupling between the two phases.

  10. Fractionation of Saprolegnia diclina (Oomycetes) satelite DNAs by AgNO3/Cs2SO4 density gradient centrifugation.

    PubMed

    Neish, G A; Green, B R

    1977-12-14

    Saprolegnia diclina DNA has been fractionated using preparative AgNO3/Cs2SO4 and CsCl density gradients. In addition to the previously identified major satellite DNA, there are two minor DNA components banding at 1.682 and 1.701 g - cm(-3) in CsCl. Purified major satellite DNA bands at 1.707 g - cm(-3) giving a base composition of 48% G + C in good agreement with 47% G + C calculated from its Tm value. The nuclear DNA base composition is 58% G + C by both methods. The base composition of the major satellite DNA suggests that it may represent ribosomal DNA cistrons.

  11. The cardiovascular response to the AGS

    NASA Technical Reports Server (NTRS)

    Cardus, David; Mctaggart, Wesley G.

    1993-01-01

    This paper reports the preliminary results of experiments on human subjects conducted to study the cardiovascular response to various g-levels and exposure times using an artificial gravity simulator (AGS). The AGS is a short arm centrifuge consisting of a turntable, a traction system, a platform and four beds. Data collection hardware is part of the communication system. The AGS provides a steep acceleration gradient in subjects in the supine position.

  12. Maturation-Associated Destabilization of Hepatitis B Virus Nucleocapsid

    PubMed Central

    Cui, Xiuji; Ludgate, Laurie; Ning, Xiaojun

    2013-01-01

    The mature nucleocapsid (NC) of hepatitis B virus containing the relaxed circular (RC) DNA genome can be secreted extracellularly as virions after envelopment with the viral surface proteins or, alternatively, can be disassembled to release RC DNA (i.e., uncoating) into the host cell nucleus to form the covalently closed circular (CCC) DNA, which sustains viral replication and persistence. In contrast, immature NCs containing the viral single-stranded DNA or the pregenomic RNA are incompetent for either envelopment or uncoating. Little is currently known about how mature NCs, and not the immature ones, are specifically selected for these processes. Here, we have carried out a biochemical analysis of the different NC populations upon their separation through sucrose gradient centrifugation. We have found that the maturation of NCs is associated with their destabilization, manifested as increased protease and nuclease sensitivity, altered sedimentation during sucrose gradient centrifugation, and retarded mobility during native agarose gel electrophoresis. Also, three distinct populations of intracellular mature NCs could be differentiated based on these characteristics. Furthermore, mature NCs generated in vitro under cell-free conditions acquired similar properties. These results have thus revealed significant structural changes associated with NC maturation that likely play a role in the selective uncoating of the mature NC for CCC DNA formation and/or its preferential envelopment for virion secretion. PMID:23966388

  13. [A thermodynamic study on bovine spermatozoa by microcalorimetry after Percoll density-gradient centrifugation - experimental probe of its utility in andrology].

    PubMed

    Fischer, C; Scherfer-Brähler, V; Müller-Schlösser, F; Schröder-Printzen, I; Weidner, W

    2007-05-01

    Microcalorimetric measurements can be used for recording exothermic or endothermic summation effects of a great variety of biological processes. The aim of the present study was to examine the usefullness of the microcalorimetry method to characterise the biological activity of spermatozoa. The heat flow of bovine fresh sperm as well as cryosperm samples were measured after Percoll density-gradient centrifugation in a 4-channel microcalorimeter. Various calibration times, volumes of samples and sperm concentrations were tested and analysed. Sperm concentration was recorded by a computer-assisted, computer-aided software system method (CASA). Using a calibration time of 15 minutes, the heat signal of the fresh and cryosperm samples showed a characteristic peak after 39.5 min and 38.1 min (mean), respectively, with a significant correlation to sample volume and sperm concentration (p < 0.05). For obtaining the best results, a sample volume of 1 ml and a sperm concentration of more than 50 x 10 (6)/mL was used. With microcalorimetric measurements the biological activity of spermatozoa could be recorded for reproducible results, thus opening the way to an automatised ejaculate analysis in the future. More investigations are necessary to correlate microcalorimetric parameters with semen function.

  14. CLC-Nt1, a putative chloride channel protein of tobacco, co-localizes with mitochondrial membrane markers.

    PubMed Central

    Lurin, C; Güclü, J; Cheniclet, C; Carde, J P; Barbier-Brygoo, H; Maurel, C

    2000-01-01

    The voltage-dependent chloride channel (CLC) family of membrane proteins has cognates in animals, yeast, bacteria and plants, and chloride-channel activity has been assigned to most of the animal homologues. Lack of evidence of CLC functions in plants prompted us to characterize the cellular localization of the tobacco CLC-Nt1 protein. Specific polyclonal antibodies were raised against an N-terminal polypeptide of CLC-Nt1. These antibodies were used to probe membrane proteins prepared by various cell-fractionation methods. These included aqueous two-phase partitioning (for plasma membranes), free-flow electrophoresis (for vacuolar and plasma membranes), intact vacuole isolation, Percoll-gradient centrifugation (for plastids and mitochondria) and stepped, linear, sucrose-density-gradient centrifugation (for mitochondria). Each purified membrane fraction was characterized with specific marker enzyme activities or antibodies. Our studies ruled out the possibility that the major cell localization of CLC-Nt1 was the vacuolar or plasma membranes, the endoplasmic reticulum, the Golgi apparatus or the plastids. In contrast, we showed that the tobacco CLC-Nt1 specifically co-localized with the markers of the mitochondrial inner membrane, cytochrome c oxidase and NAD9 protein. CLC-Nt1 may correspond to the inner membrane anion channel ('IMAC') described previously in animal and plant mitochondria. PMID:10816421

  15. CLC-Nt1, a putative chloride channel protein of tobacco, co-localizes with mitochondrial membrane markers.

    PubMed

    Lurin, C; Güclü, J; Cheniclet, C; Carde, J P; Barbier-Brygoo, H; Maurel, C

    2000-06-01

    The voltage-dependent chloride channel (CLC) family of membrane proteins has cognates in animals, yeast, bacteria and plants, and chloride-channel activity has been assigned to most of the animal homologues. Lack of evidence of CLC functions in plants prompted us to characterize the cellular localization of the tobacco CLC-Nt1 protein. Specific polyclonal antibodies were raised against an N-terminal polypeptide of CLC-Nt1. These antibodies were used to probe membrane proteins prepared by various cell-fractionation methods. These included aqueous two-phase partitioning (for plasma membranes), free-flow electrophoresis (for vacuolar and plasma membranes), intact vacuole isolation, Percoll-gradient centrifugation (for plastids and mitochondria) and stepped, linear, sucrose-density-gradient centrifugation (for mitochondria). Each purified membrane fraction was characterized with specific marker enzyme activities or antibodies. Our studies ruled out the possibility that the major cell localization of CLC-Nt1 was the vacuolar or plasma membranes, the endoplasmic reticulum, the Golgi apparatus or the plastids. In contrast, we showed that the tobacco CLC-Nt1 specifically co-localized with the markers of the mitochondrial inner membrane, cytochrome c oxidase and NAD9 protein. CLC-Nt1 may correspond to the inner membrane anion channel ('IMAC') described previously in animal and plant mitochondria.

  16. Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

    NASA Technical Reports Server (NTRS)

    Gazda, Daniel B.; Schultz, John R.; Clarke, Mark S.

    2007-01-01

    Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

  17. Improved quality of cryopreserved cheetah (Acinonyx jubatus) spermatozoa after centrifugation through Accudenz.

    PubMed

    Crosier, Adrienne E; Henghali, Josephine N; Howard, Jogayle; Pukazhenthi, Budhan S; Terrell, Kimberly A; Marker, Laurie L; Wildt, David E

    2009-01-01

    Sperm cryopreservation, in combination with assisted reproductive techniques, is a valuable tool for the genetic management of endangered felids. However, the acrosome of the cheetah spermatozoon is especially sensitive to cryopreservation, with approximately 40% of spermatozoa experiencing acrosomal damage immediately after thawing and then another approximately 15% loss during the next 4 hours in vitro. Additionally, thawing causes a reduction in sperm motility by approximately 20% with another decrease of approximately 12% during subsequent incubation in vitro. We hypothesized that slow removal of glycerol from cryopreserved cheetah spermatozoa using an Accudenz gradient would improve acrosomal integrity, sperm motility longevity, and structural morphology. Accudenz was compared with traditional cheetah sperm processing methods for glycerol removal that involves washing, multistep resuspension, and swim-up processing. Electroejaculates (n = 21 total from 8 males) were washed in Ham F10 medium, and sperm pellets were resuspended in TEST-yolk buffer with 0% glycerol. Samples were cryopreserved in straws in 4% final glycerol, thawed, and assessed for percent intact acrosomes (% IA), percent motility (% M), and forward progressive status (FPS; scale, 0-5). Sperm motility index (SMI) was calculated as (% M + [FPS x 20]) / 2. In study 1, glycerol removal by centrifugation through an Accudenz gradient (4%, 10%) was compared with traditional sperm washing (control) and multistep resuspension protocols. At each time after centrifugation (hourly for 4 hours), % IA was improved (P < .05) for Accudenz (range, 36%-39%) compared with control (30%-33%) and multistep (29%-33%) treatments. In study 2, a modified Accudenz protocol was compared with traditional washing and was found to improve (P < .05) SMI (range, 52-64) compared with controls (range, 41-52) at each time postthaw after centrifugation. In study 3, swim-up processed sperm were compared with those treated by centrifugation through Accudenz and traditional sperm washing for improving sperm morphology. The percentage of structurally-normal sperm recovered postthawing increased (P < .05) for both the Accudenz (38%) and swim-up (33%) treatments compared with controls (21%). Percent IA and SMI also were improved (P < .05) for Accudenz (range, 39%-47% and 46-59, respectively) compared with controls (range, 26%-33% and 40-53, respectively). Results indicate that using Accudenz for glycerol removal from cryopreserved cheetah sperm mitigates the significant loss in sperm quality that occurs after freeze-thawing. This alleviation of cellular damage resulting from cryopreservation contributes to a more than 10% improvement in overall sperm motility and, more importantly, allows retention of 40% or more of sperm with intact acrosomes.

  18. Particle Swarm Optimization of Low-Thrust, Geocentric-to-Halo-Orbit Transfers

    NASA Astrophysics Data System (ADS)

    Abraham, Andrew J.

    Missions to Lagrange points are becoming increasingly popular amongst spacecraft mission planners. Lagrange points are locations in space where the gravity force from two bodies, and the centrifugal force acting on a third body, cancel. To date, all spacecraft that have visited a Lagrange point have done so using high-thrust, chemical propulsion. Due to the increasing availability of low-thrust (high efficiency) propulsive devices, and their increasing capability in terms of fuel efficiency and instantaneous thrust, it has now become possible for a spacecraft to reach a Lagrange point orbit without the aid of chemical propellant. While at any given time there are many paths for a low-thrust trajectory to take, only one is optimal. The traditional approach to spacecraft trajectory optimization utilizes some form of gradient-based algorithm. While these algorithms offer numerous advantages, they also have a few significant shortcomings. The three most significant shortcomings are: (1) the fact that an initial guess solution is required to initialize the algorithm, (2) the radius of convergence can be quite small and can allow the algorithm to become trapped in local minima, and (3) gradient information is not always assessable nor always trustworthy for a given problem. To avoid these problems, this dissertation is focused on optimizing a low-thrust transfer trajectory from a geocentric orbit to an Earth-Moon, L1, Lagrange point orbit using the method of Particle Swarm Optimization (PSO). The PSO method is an evolutionary heuristic that was originally written to model birds swarming to locate hidden food sources. This PSO method will enable the exploration of the invariant stable manifold of the target Lagrange point orbit in an effort to optimize the spacecraft's low-thrust trajectory. Examples of these optimized trajectories are presented and contrasted with those found using traditional, gradient-based approaches. In summary, the results of this dissertation find that the PSO method does, indeed, successfully optimize the low-thrust trajectory transfer problem without the need for initial guessing. Furthermore, a two-degree-of-freedom PSO problem formulation significantly outperformed a one-degree-of-freedom formulation by at least an order of magnitude, in terms of CPU time. Finally, the PSO method is also used to solve a traditional, two-burn, impulsive transfer to a Lagrange point orbit using a hybrid optimization algorithm that incorporates a gradient-based shooting algorithm as a pre-optimizer. Surprisingly, the results of this study show that "fast" transfers outperform "slow" transfers in terms of both Deltav and time of flight.

  19. No evidence for an open vessel effect in centrifuge-based vulnerability curves of a long-vesselled liana (Vitis vinifera).

    PubMed

    Jacobsen, Anna L; Pratt, R Brandon

    2012-06-01

    Vulnerability to cavitation curves are used to estimate xylem cavitation resistance and can be constructed using multiple techniques. It was recently suggested that a technique that relies on centrifugal force to generate negative xylem pressures may be susceptible to an open vessel artifact in long-vesselled species. Here, we used custom centrifuge rotors to measure different sample lengths of 1-yr-old stems of grapevine to examine the influence of open vessels on vulnerability curves, thus testing the hypothesized open vessel artifact. These curves were compared with a dehydration-based vulnerability curve. Although samples differed significantly in the number of open vessels, there was no difference in the vulnerability to cavitation measured on 0.14- and 0.271-m-long samples of Vitis vinifera. Dehydration and centrifuge-based curves showed a similar pattern of declining xylem-specific hydraulic conductivity (K(s)) with declining water potential. The percentage loss in hydraulic conductivity (PLC) differed between dehydration and centrifuge curves and it was determined that grapevine is susceptible to errors in estimating maximum K(s) during dehydration because of the development of vessel blockages. Our results from a long-vesselled liana do not support the open vessel artifact hypothesis. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  20. Clean-in-Place and Reliability Testing of a Commercial 12.5-cm Annular Centrifugal Contactor at the INL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N. R. Mann; T. G. Garn; D. H. Meikrantz

    2007-09-01

    The renewed interest in advancing nuclear energy has spawned the research of advanced technologies for recycling nuclear fuel. A significant portion of the advanced fuel cycle includes the recovery of selected actinides by solvent extraction methods utilizing centrifugal contactors. Although the use of centrifugal contactors for solvent extraction is widely known, their operation is not without challenges. Solutions generated from spent fuel dissolution contain unknown quantities of undissolved solids. A majority of these solids will be removed via various methods of filtration. However, smaller particles are expected to carry through to downstream solvent extraction processes and equipment. In addition, solids/precipitatesmore » brought about by mechanical or chemical upsets are another potential area of concern. During processing, particulate captured in the rotor assembly by high centrifugal forces eventually forms a cake-like structure on the inner wall introducing balance problems and negatively affecting phase separations. One of the features recently developed for larger engineering scale Annular Centrifugal Contactors (ACCs) is the Clean-In-Place (CIP) capability. Engineered spray nozzles were installed into the hollow central rotor shaft in all four quadrants of the rotor assembly. This arrangement allows for a very convenient and effective method of solids removal from within the rotor assembly.« less

  1. Clean-in-Place and Reliability Testing of a Commercial 12.5 cm Annular Centrifugal Contactor at the INL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    N. R. Mann; T. G. Garn; D. H. Meikrantz

    2007-09-01

    The renewed interest in advancing nuclear energy has spawned the research of advanced technologies for recycling nuclear fuel. A significant portion of the advanced fuel cycle includes the recovery of selected actinides by solvent extraction methods utilizing centrifugal contactors. Although the use of centrifugal contactors for solvent extraction is widely known, their operation is not without challenges. Solutions generated from spent fuel dissolution contain unknown quantities of undissolved solids. A majority of these solids will be removed via various methods of filtration. However, smaller particles are expected to carry through to downstream solvent extraction processes and equipment. In addition, solids/precipitatesmore » brought about by mechanical or chemical upsets are another potential area of concern. During processing, particulate captured in the rotor assembly by high centrifugal forces eventually forms a cake-like structure on the inner wall introducing balance problems and negatively affecting phase separations. One of the features recently developed for larger engineering scale Annular Centrifugal Contactors (ACCs) is the Clean-In-Place (CIP) capability. Engineered spray nozzles were installed into the hollow central rotor shaft in all four quadrants of the rotor assembly. This arrangement allows for a very convenient and effective method of solids removal from within the rotor assembly.« less

  2. Gravity in a Mine Shaft.

    ERIC Educational Resources Information Center

    Hall, Peter M.; Hall, David J.

    1995-01-01

    Discusses the effects of gravity, local density compared to the density of the earth, the mine shaft, centrifugal force, and air buoyancy on the weight of an object at the top and at the bottom of a mine shaft. (JRH)

  3. Uplifting Behavior of Shallow Buried Pipe in Liquefiable Soil by Dynamic Centrifuge Test

    PubMed Central

    Liu, Jingwen; Ling, Daosheng

    2014-01-01

    Underground pipelines are widely applied in the so-called lifeline engineerings. It shows according to seismic surveys that the damage from soil liquefaction to underground pipelines was the most serious, whose failures were mainly in the form of pipeline uplifting. In the present study, dynamic centrifuge model tests were conducted to study the uplifting behaviors of shallow-buried pipeline subjected to seismic vibration in liquefied sites. The uplifting mechanism was discussed through the responses of the pore water pressure and earth pressure around the pipeline. Additionally, the analysis of force, which the pipeline was subjected to before and during vibration, was introduced and proved to be reasonable by the comparison of the measured and the calculated results. The uplifting behavior of pipe is the combination effects of multiple forces, and is highly dependent on the excess pore pressure. PMID:25121140

  4. The effect of inlet swirl on the dynamics of long annular seals in centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Ismail, M.; Brown, R. D.; France, D.

    1994-01-01

    This paper describes additional results from a continuing research program which aims to identify the dynamics of long annular seals in centrifugal pumps. A seal test rig designed at Heriot-Watt University and commissioned at Weir Pumps Research Laboratory in Alloa permits the identification of mass, stiffness, and damping coefficients using a least-squares technique based on the singular value decomposition method. The analysis is carried out in the time domain using a multi-fiequency forcing function. The experimental method relies on the forced excitation of a flexibly supported stator by two hydraulic shakers. Running through the stator embodying two symmetrical balance drum seals is a rigid rotor supported in rolling element bearings. The only physical connection between shaft and stator is the pair of annular gaps filled with pressurized water discharged axially. The experimental coefficients obtained from the tests are compared with theoretical values.

  5. Plane waves in magneto-thermoelastic anisotropic medium based on (L-S) theory under the effect of Coriolis and centrifugal forces

    NASA Astrophysics Data System (ADS)

    Alesemi, Meshari

    2018-04-01

    The objective of this research is to illustrate the effectiveness of the thermal relaxation time based on the theory of Lord-Shulman (L-S), Coriolis and Centrifugal Forces on the reflection coefficients of plane waves in an anisotropic magneto-thermoelastic medium. Assuming the elastic medium is rotating with stable angular velocity and the imposed magnetic field is parallel to the boundary of the half-space. The basic equations of a transversely isotropic rotating magneto-thermoelastic medium are formulated according to thermoelasticity theory of Lord-Shulman (L-S). Next to that, getting the velocity equation which is illustrated to show existence of three quasi-plane waves propagating in the medium. The amplitude ratios coefficients of these plane waves have been given and then computed numerically and plotted graphically to demonstrate the influences of the rotation on the Zinc material.

  6. Unsteady Newton-Busemann flow theory. Part 2: Bodies of revolution

    NASA Technical Reports Server (NTRS)

    Hui, W. H.; Tobak, M.

    1981-01-01

    Newtonian flow theory for unsteady flow past oscillating bodies of revolution at very high Mach numbers is completed by adding a centrifugal force correction to the impact pressures. Exact formulas for the unsteady pressure and the stability derivatives are obtained in closed form and are applicable to bodies of revolution that have arbitrary shapes, arbitrary thicknesses, and either sharp or blunt noses. The centrifugal force correction arising from the curved trajectories followed by the fluid particles in unsteady flow cannot be neglected even for the case of a circular cone. With this correction, the present theory is in excellent agreement with experimental results for sharp cones and for cones with small nose bluntness; gives poor agreement with the results of experiments in air for bodies with moderate or large nose bluntness. The pitching motions of slender power-law bodies of revulution are shown to be always dynamically stable according to Newton-Busemann theory.

  7. [Galileo and centrifugal force].

    PubMed

    Vilain, Christiane

    This work intends to focus on Galileo's study of what is now called "centrifugal force," within the framework of the Second Day of his Dialogo written in 1632, rather than on the previously published commentaries on the topic. Galileo proposes three geometrical demonstrations in order to prove that gravity will always overcome centrifugalforce, and that the potential rotation of the Earth, whatever its speed, cannot in any case project objects beyond it. Each of these demonstrations must consequently contain an error and it has seemed to us that the first one had not been understood up until now. Our analysis offers an opportunity to return to Galileo's geometrical representation of dynamical questions; actually, we get an insight into the sophistication of Galileo's practices more than into his mistakes. Our second point, concerning the historiography of the problem, shows an evolution from anachronic critics to more contextual considerations, in the course of the second half of the twentieth century.

  8. Freeze-out extraction of monocarboxylic acids from water into acetonitrile under the action of centrifugal forces

    NASA Astrophysics Data System (ADS)

    Bekhterev, V. N.

    2016-10-01

    It is established that the efficiency of the freezing-out extraction of monocarboxylic acids C3-C;8 and sorbic acid from water into acetonitrile increases under the action of centrifugal forces. The linear growth of the partition coefficient in the homologous series of C2-C8 acids with an increase in molecule length, and the difference between the efficiency of extracting sorbic and hexanoic acid, are discussed using a theoretical model proposed earlier and based on the adsorption-desorption equilibrium of the partition of dissolved organic compounds between the resulting surface of ice and the liquid phase of the extract. The advantages of the proposed technique with respect to the degree of concentration over the method of low-temperature liquid-liquid extraction are explained in light of the phase diagram for the water-acetonitrile mixture.

  9. Research opportunities with the Centrifuge Facility

    NASA Technical Reports Server (NTRS)

    Funk, Glenn A.

    1992-01-01

    The Centrifuge Facility on Space Station Freedom will consist of a 2.5-meter diameter Centrifuge accommodating two concentric rings of habitats and providing variable g-forces between 0.01 g and 2.0 g; modular habitats providing housing and lifesupport for rats, mice, and plants; a habitat holding system providing power, water, airflow and other utilities to several modular habitats; and a life sciences glovebox, an isolated work volume accommodating simultaneous operations by at least two scientists and providing lighting, airflow, video and data access, and other experiment support functions. The centrifuge facility will enable long-duration animal and plant microgravity research not previously possible in the NASA flight research program. It will offer unprecedented opportunities for use of on-board 1-g control populations and statistically significant numbers of specimens. On orbit 1-g controls will allow separation of the effects of microgravity from other environmental factors. Its selectable-g and simultaneous multiple-g capabilities will enable studies of gravitational thresholds, the use of artificial gravity as a countermeasure to the effects of microgravity, and ready simulation of Lunar and Martian gravities.

  10. Manufacturing of Open-Cell Zn-22Al-2Cu Alloy Foams by a Centrifugal-Replication Process

    NASA Astrophysics Data System (ADS)

    Sánchez, A.; Cruz, A.; Rivera, J. E.; Romero, J. A.; Suárez, M. A.; Gutiérrez, V. H.

    2018-01-01

    Centrifugal force was used to produce open-cell Zn-22Al-2Cu alloy foams by the replication method. Three different sizes (0.50, 0.69, and 0.95 mm) of NaCl spherical particles were used as space holders. A relatively low infiltration pressure was required to infiltrate completely the liquid metal into the three pore sizes, and it was determined based on the centrifugation system parameters. The infiltration pressure required was decreased when the diameter of the particle was increased. The porosity of the foam was increased from 58 to 63 pct, when the pore size was increased from 0.50 to 0.95 mm, while the relative density was decreased from 0.42 to 0.36. The NaCl preform was preheated to avoid the freezing and to keep the rheological properties of the melt. The centrifugal-replication method is a suitable technique for the fabrication of open-cell Zn-Al-Cu alloy foams with small pore size. The compressive mechanical properties of the open-cell Zn-22Al-2Cu foams increased when the pore size decreased.

  11. Method and apparatus for biological material separation

    DOEpatents

    Robinson, Donna L.

    2005-05-10

    There has been invented an apparatus comprising a separation barrier for excluding denser cell materials from less dense cell materials after centrifuging of the cells so that selected materials can be withdrawn from the less dense cell materials without inclusion of the denser cell materials or clogging of sampling equipment with denser cell materials. Cells from which selected material is to be withdrawn are centrifuged, either as cells or cells in media. Once the denser cell materials are isolated in a layer by centrifugal force, an invention screen or seive is submerged in the less dense cell material to a level above the layer of denser cell materials to isolate the denser cell materials from the less dense cell materials, preventing mixing of the denser cell materials back into the less dense cell materials when the cells or the cells in media are no longer being centrifuged and to prevent clogging of sampling equipment with denser cell materials. In a particularly useful application of the invention method and apparatus, plasmid DNA can be withdrawn from less dense cell materials without contamination or interference with denser cell materials.

  12. Scrotal Hematoma Precipitated by Centrifuge Training in a Fighter Pilot with an Asymptomatic Varicocele.

    PubMed

    Kampel, Liyona; Klang, Eyal; Winkler, Harry; Gordon, Barak; Frenkel-Nir, Yael; Shoam, Yifat Erlich

    2015-12-01

    Varicocele is quite common in the general population, affecting up to 15% of men. It is not considered disqualifying for the pilot's training program of the Israeli Air Force as long as there are no related symptoms or associated pathologies. During combat flight, increased venous pressure due to acceleration forces and anti-G straining maneuvers, used to counteract high gravitational G forces, can theoretically aggravate the venous blood pooling in varicocele, leading to rupture. We describe a case of a young fighter-jet pilot presenting with a painful inguinal hematoma extending to the scrotum a day after participating in centrifuge training. Sonographic examination demonstrated dilated spermatic veins and intratesticular varicocele along with subcutaneous thickening of the scrotal wall consistent with hematoma. The effects of high G loads on blood flow in spermatic veins, and especially in varicocele, still need to be determined. Varicocele rupture has been described in relation to increased intra-abdominal pressure and could theoretically occur during anti-G straining maneuvers. Such an acute adverse event during combat flight can be detrimental to flight safety and the pilot's well-being.

  13. Centrifuge Testing of a Partially-Confined FC-72 Spray

    DTIC Science & Technology

    2006-11-01

    induced body forces. Heat transfer associated with closed - loop spray cooling will be affected by acceleration body forces, the extent of which is not...impingement cooling, spray cooling, heat pipes , loop heat pipes , carbon foam impregnated with phase-change materials, and combinations of the above...reduced gravity and elevated gravity experiments to help prove viability of pulsating heat pipes (PHPs) for space applications. The PHPs, filled

  14. Alternative polymer separation technology by centrifugal force in a melted state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dobrovszky, Károly; Ronkay, Ferenc, E-mail: ronkay@pt.bme.hu

    2014-11-15

    Highlights: • Waste separation should take place at high purity. • Developed a novel, alternative separation method, where the separation occurred in a melted state by centrifugal forces. • Possibility of separation two different plastics into neat fractions. • High purity fractions were established at granulates and also at prefabricated blend. • Results were verified by DSC, optical microscopy and Raman spectroscopy. - Abstract: In order to upgrade polymer waste during recycling, separation should take place at high purity. The present research was aimed to develop a novel, alternative separation opportunity, where the polymer fractions were separated by centrifugal forcemore » in melted state. The efficiency of the constructed separation equipment was verified by two immiscible plastics (polyethylene terephthalate, PET; low density polyethylene, LDPE), which have a high difference of density, and of which large quantities can also be found in the municipal solid waste. The results show that the developed equipment is suitable not only for separating dry blended mixtures of PET/LDPE into pure components again, but also for separating prefabricated polymer blends. By this process it becomes possible to recover pure polymer substances from multi-component products during the recycling process. The adequacy of results was verified by differential scanning calorimetry (DSC) measurement as well as optical microscopy and Raman spectroscopy.« less

  15. Particle dynamics and pattern formation in a rotating suspension of positively buoyant particles

    NASA Astrophysics Data System (ADS)

    Konidena, Sudarshan; Lee, Jonghoon; Reddy, K. Anki; Singh, Anugrah

    2018-04-01

    Numerical simulations of positively buoyant suspension in a horizontally rotating cylinder were performed to study the formation of radial and axial patterns. The order parameter for the low-frequency segregated phase and dispersed phase is similar to that predicted for the settling suspension by Lee and Ladd [J. Fluid Mech. 577, 183 (2007), 10.1017/S002211200700465X], which is the average angular velocity of the particles. The particle density profiles for axial bands in the buoyancy-dominated phase shows an amplitude equivalent to the diameter of the cylinder. Axial density profiles show sinusoidal behavior for the drag-dominant phase and oscillating sinusoidal behavior for the centrifugal-force-dominant phase. Results also indicate that the traveling bands are formed as a consequence of the inhomogeneous distribution of particles arising from a certain imbalance of drag, buoyancy, and centrifugal forces. In the centrifugal limit, particles move towards the center of the cylinder, aggregating to form a dense core of particles with its axis coinciding with that of the rotating cylinder, a behavior which is in contrast to the sedimenting particles. The particle distribution patterns obtained from the simulations are found to be in good agreement with the experiments of Kalyankar et al. [Phys. Fluids 20, 083301 (2008), 10.1063/1.2970156].

  16. Preflight screening techniques for centrifuge-simulated suborbital spaceflight.

    PubMed

    Pattarini, James M; Blue, Rebecca S; Castleberry, Tarah L; Vanderploeg, James M

    2014-12-01

    Historically, space has been the venue of the healthy individual. With the advent of commercial spaceflight, we face the novel prospect of routinely exposing spaceflight participants (SPFs) with multiple comorbidities to the space environment. Preflight screening procedures must be developed to identify those individuals at increased risk during flight. We examined the responses of volunteers to centrifuge accelerations mimicking commercial suborbital spaceflight profiles to evaluate how potential SFPs might tolerate such forces. We evaluated our screening process for medical approval of subjects for centrifuge participation for applicability to commercial spaceflight operations. All registered subjects completed a medical questionnaire, physical examination, and electrocardiogram. Subjects with identified concerns including cardiopulmonary disease, hypertension, and diabetes were required to provide documentation of their conditions. There were 335 subjects who registered for the study, 124 who completed all prescreening, and 86 subjects who participated in centrifuge trials. Due to prior medical history, five subjects were disqualified, most commonly for psychiatric reasons or uncontrolled medical conditions. Of the subjects approved, four individuals experienced abnormal physiological responses to centrifuge profiles, including one back strain and three with anxiety reactions. The screening methods used were judged to be sufficient to identify individuals physically capable of tolerating simulated suborbital flight. Improved methods will be needed to identify susceptibility to anxiety reactions. While severe or uncontrolled disease was excluded, many subjects successfully participated in centrifuge trials despite medical histories of disease that are disqualifying under historical spaceflight screening regimes. Such screening techniques are applicable for use in future commercial spaceflight operations.

  17. Testing thermal gradient driving force for grain boundary migration using molecular dynamics simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bai, Xian-Ming; Zhang, Yongfeng; Tonks, Michael R.

    2015-02-01

    Strong thermal gradients in low-thermal-conductivity ceramics may drive extended defects, such as grain boundaries and voids, to migrate in preferential directions. In this work, molecular dynamics simulations are conducted to study thermal gradient driven grain boundary migration and to verify a previously proposed thermal gradient driving force equation, using uranium dioxide as a model system. It is found that a thermal gradient drives grain boundaries to migrate up the gradient and the migration velocity increases under a constant gradient owing to the increase in mobility with temperature. Different grain boundaries migrate at very different rates due to their different intrinsicmore » mobilities. The extracted mobilities from the thermal gradient driven simulations are compared with those calculated from two other well-established methods and good agreement between the three different methods is found, demonstrating that the theoretical equation of the thermal gradient driving force is valid, although a correction of one input parameter should be made. The discrepancy in the grain boundary mobilities between modeling and experiments is also discussed.« less

  18. Coronal Jet Collimation by Nonlinear Induced Flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vasheghani Farahani, S.; Hejazi, S. M.

    2017-08-01

    Our objective is to study the collimation of solar jets by nonlinear forces corresponding to torsional Alfvén waves together with external forces. We consider a straight, initially non-rotating, untwisted magnetic cylinder embedded in a plasma with a straight magnetic field, where a shear between the internal and external flows exists. By implementing magnetohydrodynamic theory and taking into account the second-order thin flux tube approximation, the balance between the internal nonlinear forces is visualized. The nonlinear differential equation containing the ponderomotive, magnetic tension, and centrifugal forces in the presence of the shear flow is obtained. The solution presents the scale ofmore » influence of the propagating torsional Alfvén wave on compressive perturbations. Explicit expressions for the compressive perturbations caused by the forces connected to the torsional Alfvén wave show that, in the presence of a shear flow, the magnetic tension and centrifugal forces do not cancel each other’s effects as they did in its absence. This shear flow plays in favor of the magnetic tension force, resulting in a more efficient collimation. Regarding the ponderomotive force, the shear flow has no effect. The phase relations highlight the interplay of the shear flow and the plasma- β . As the shear flow and plasma- β increase, compressive perturbation amplitudes emerge. We conclude that the jet collimation due to the torsional Alfvén wave highly depends on the location of the jet. The shear flow tightens the collimation as the jet elevates up to the solar corona.« less

  19. States of phage T3/T7 capsids: buoyant density centrifugation and cryo-EM.

    PubMed

    Serwer, Philip; Wright, Elena T; Demeler, Borries; Jiang, Wen

    2018-04-01

    Mature double-stranded DNA bacteriophages have capsids with symmetrical shells that typically resist disruption, as they must to survive in the wild. However, flexibility and associated dynamism assist function. We describe biochemistry-oriented procedures used to find previously obscure flexibility for capsids of the related phages, T3 and T7. The primary procedures are hydration-based buoyant density ultracentrifugation and purified particle-based cryo-electron microscopy (cryo-EM). We review the buoyant density centrifugation in detail. The mature, stable T3/T7 capsid is a shell flexibility-derived conversion product of an initially assembled procapsid (capsid I). During DNA packaging, capsid I expands and loses a scaffolding protein to form capsid II. The following are observations made with capsid II. (1) The in vivo DNA packaging of wild type T3 generates capsid II that has a slight (1.4%), cryo-EM-detected hyper-expansion relative to the mature phage capsid. (2) DNA packaging in some altered conditions generates more extensive hyper-expansion of capsid II, initially detected by hydration-based preparative buoyant density centrifugation in Nycodenz density gradients. (3) Capsid contraction sometimes occurs, e.g., during quantized leakage of DNA from mature T3 capsids without a tail.

  20. Pea Chaperones under Centrifugation

    NASA Astrophysics Data System (ADS)

    Talalaiev, Oleksandr

    2008-06-01

    Etiolated Pisum sativum seedlings were subjected to altered g-forces by centrifugation (3-14g). By using semiquantitative RT-PCR, we studied transcripts of pea genes coding for chaperones that are representatives of small heat shock proteins (sHsps) family. Four members from the different classes of sHsps: cytosolic Hsp17.7 and Hsp18.1 (class I and class II accordingly), chloroplast Hsp21 (class III) and endoplasmic reticulum Hsp22.7 (class IV) were investigated. We conclude that exposure to 3, 7, 10 and 14g for 1h did not affect the level of sHsp transcripts.

  1. Method for packing chromatographic beds

    DOEpatents

    Freeman, David H.; Angeles, Rosalie M.; Keller, Suzanne

    1991-01-01

    Column chromatography beds are packed through the application of static force. A slurry of the chromatography bed material and a non-viscous liquid is filled into the column plugged at one end, and allowed to settle. The column is transferred to a centrifuge, and centrifuged for a brief period of time to achieve a predetermined packing level, at a range generally of 100-5,000 gravities. Thereafter, the plug is removed, other fixtures may be secured, and the liquid is allowed to flow out through the bed. This results in an evenly packed bed, with no channeling or preferential flow characteristics.

  2. The rotational feedback on linear-momentum balance in glacial isostatic adjustment

    NASA Astrophysics Data System (ADS)

    Martinec, Zdenek; Hagedoorn, Jan

    2015-04-01

    The influence of changes in surface ice-mass redistribution and associated viscoelastic response of the Earth, known as glacial-isostatic adjustment (GIA), on the Earth's rotational dynamics has long been known. Equally important is the effect of the changes in the rotational dynamics on the viscoelastic deformation of the Earth. This signal, known as the rotational feedback, or more precisely, the rotational feedback on the sea-level equation, has been mathematically described by the sea-level equation extended for the term that is proportional to perturbation in the centrifugal potential and the second-degree tidal Love number. The perturbation in the centrifugal force due to changes in the Earth's rotational dynamics enters not only into the sea-level equation, but also into the conservation law of linear momentum such that the internal viscoelastic force, the perturbation in the gravitational force and the perturbation in the centrifugal force are in balance. Adding the centrifugal-force perturbation to the linear-momentum balance creates an additional rotational feedback on the viscoelastic deformations of the Earth. We term this feedback mechanism as the rotational feedback on the linear-momentum balance. We extend both the time-domain method for modelling the GIA response of laterally heterogeneous earth models and the traditional Laplace-domain method for modelling the GIA-induced rotational response to surface loading by considering the rotational feedback on linear-momentum balance. The correctness of the mathematical extensions of the methods is validated numerically by comparing the polar motion response to the GIA process and the rotationally-induced degree 2 and order 1 spherical harmonic component of the surface vertical displacement and gravity field. We present the difference between the case where the rotational feedback on linear-momentum balance is considered against that where it is not. Numerical simulations show that the resulting difference in radial displacement and sea-level change between these situations since the Last Glacial Maximum reaches values of ± 25 m and ± 1.8 m, respectively. Furthermore, the surface deformation pattern is modified by up to 10% in areas of former or ongoing glaciation, but by up to 50% at the bottom of the southern Indian ocean. This also results in the movement of coastlines during the last deglaciation to differ between the two cases due to the difference in the ocean loading, which is seen for instance in the area around Hudson Bay, Canada, and along the Chinese, Australian, or Argentinian coastlines.

  3. The rotational feedback on linear-momentum balance in glacial isostatic adjustment

    NASA Astrophysics Data System (ADS)

    Martinec, Zdeněk; Hagedoorn, Jan

    2014-12-01

    The influence of changes in surface ice-mass redistribution and associated viscoelastic response of the Earth, known as glacial isostatic adjustment (GIA), on the Earth's rotational dynamics has long been known. Equally important is the effect of the changes in the rotational dynamics on the viscoelastic deformation of the Earth. This signal, known as the rotational feedback, or more precisely, the rotational feedback on the sea level equation, has been mathematically described by the sea level equation extended for the term that is proportional to perturbation in the centrifugal potential and the second-degree tidal Love number. The perturbation in the centrifugal force due to changes in the Earth's rotational dynamics enters not only into the sea level equation, but also into the conservation law of linear momentum such that the internal viscoelastic force, the perturbation in the gravitational force and the perturbation in the centrifugal force are in balance. Adding the centrifugal-force perturbation to the linear-momentum balance creates an additional rotational feedback on the viscoelastic deformations of the Earth. We term this feedback mechanism, which is studied in this paper, as the rotational feedback on the linear-momentum balance. We extend both the time-domain method for modelling the GIA response of laterally heterogeneous earth models developed by Martinec and the traditional Laplace-domain method for modelling the GIA-induced rotational response to surface loading by considering the rotational feedback on linear-momentum balance. The correctness of the mathematical extensions of the methods is validated numerically by comparing the polar-motion response to the GIA process and the rotationally induced degree 2 and order 1 spherical harmonic component of the surface vertical displacement and gravity field. We present the difference between the case where the rotational feedback on linear-momentum balance is considered against that where it is not. Numerical simulations show that the resulting difference in radial displacement and sea level change between these situations since the Last Glacial Maximum reaches values of ±25 and ±1.8 m, respectively. Furthermore, the surface deformation pattern is modified by up to 10 per cent in areas of former or ongoing glaciation, but by up to 50 per cent at the bottom of the southern Indian ocean. This also results in the movement of coastlines during the last deglaciation to differ between the two cases due to the difference in the ocean loading, which is seen for instance in the area around Hudson Bay, Canada and along the Chinese, Australian or Argentinian coastlines.

  4. Effect of ultrasound and centrifugal force on carambola (Averrhoa carambola L.) slices during osmotic dehydration.

    PubMed

    Barman, Nirmali; Badwaik, Laxmikant S

    2017-01-01

    Osmotic dehydration (OD) of carambola slices were carried out using glucose, sucrose, fructose and glycerol as osmotic agents with 70°Bx solute concentration, 50°C of temperature and for time of 180min. Glycerol and sucrose were selected on the basis of their higher water loss, weight reduction and lowers solid gain. Further the optimization of OD of carambola slices (5mm thick) were carried out under different process conditions of temperature (40-60°C), concentration of sucrose and glycerol (50-70°Bx), time (180min) and fruit to solution ratio (1:10) against various responses viz. water loss, solid gain, texture, rehydration ratio and sensory score according to a composite design. The optimized value for temperature, concentration of sucrose and glycerol has been found to be 50°C, 66°Bx and 66°Bx respectively. Under optimized conditions the effect of ultrasound for 10, 20, 30min and centrifugal force (2800rpm) for 15, 30, 45 and 60min on OD of carambola slices were checked. The controlled samples showed 68.14% water loss and 13.05% solid gain in carambola slices. While, the sample having 30min ultrasonic treatment showed 73.76% water loss and 9.79% solid gain; and the sample treated with centrifugal force for 60min showed 75.65% water loss and 6.76% solid gain. The results showed that with increasing in treatment time the water loss, rehydration ratio were increased and solid gain, texture were decreased. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Gradient forces on double-negative particles in optical tweezers using Bessel beams in the ray optics regime.

    PubMed

    Ambrosio, Leonardo A; Hernández-Figueroa, Hugo E

    2010-11-08

    Gradient forces on double negative (DNG) spherical dielectric particles are theoretically evaluated for v-th Bessel beams supposing geometrical optics approximations based on momentum transfer. For the first time in the literature, comparisons between these forces for double positive (DPS) and DNG particles are reported. We conclude that, contrary to the conventional case of positive refractive index, the gradient forces acting on a DNG particle may not reverse sign when the relative refractive index n goes from |n|>1 to |n|<1, thus revealing new and interesting trapping properties.

  6. Effect of centrifuge test on blood serum lipids index of cadet pilots.

    PubMed

    Wochyński, Zbigniew; Kowalczuk, Krzysztof; Kłossowski, Marek; Sobiech, Krzysztof A

    2016-01-01

    This study aimed at investigating the relationship between the lipid index (WS) in the examined cadets and duration of exposure to +Gz in the human centrifuge. The study involved 19 first-year cadets of the Polish Air Force Academy in Dęblin. Tests in the human centrifuge were repeated twice, i.e. prior to (test I) and 45 days after (test II). After exposure to +Gz, the examined cadets were divided into 2 groups. Group I (N=11) included cadets subjected to a shorter total duration of exposure to +Gz, while group II (N=8) included cadets with a longer total duration of exposure to +Gz. Total cholesterol (TC), high density lipoprotein (HDL), triglycerides (TG), and apolipoproteins A1 and B were assayed in blood serum prior to (assay A) and after (assay B) both exposures to +Gz. Low density lipoprotein (LDL) level was estimated from the Friedewald formula. WS is an own mathematical algorithm. WS was higher in group II, assay A - 10.0 and B - 10.08 of test I in the human centrifuge than in group I where the WS values were 6.91 and 6.96, respectively. WS was also higher in group II in assay A - 10.0 and B -10.1 of test II in the human centrifuge than in group I - 6.96 and 6.80, respectively. The higher value of WS in group II, both after the first and second exposure to +Gz in human centrifuge, in comparison with group I, indicated its usefulness for determination of the maximum capability of applying acceleration of the interval type during training in the human centrifuge.

  7. Alongshore Momentum Balance Over Shoreface-Connected Ridges, Fire Island, NY

    NASA Astrophysics Data System (ADS)

    Ofsthun, C.; Wu, X.; Voulgaris, G.; Warner, J. C.

    2016-12-01

    he momentum balance of alongshore flows over straight, uniform shelfs has been analyzed extensively over the last few decades. More recently, the effect of coastline curvature and how this might alter the relative significance of the momentum terms has received additional attention. In this contribution, the alongshore momentum over shelves with straight coastline, but non-uniform bathymetry is examined. Hydrodynamic and hydrographic data collected by the US Geological Survey (Fire Island Coastal Change project) on the inner shelf of Fire Island, NY over a region of shore-face connected ridges (SFCRs) are used to describe wind-induced circulation and the terms of the alongshore momentum balance equation. Analysis of the data revealed a predominantly alongshore circulation, under westward wind forcing, with localized offshore (onshore) current veering over the ridge crests (troughs). Momentum balance analysis hinted that local acceleration, advective acceleration, and bottom stress are balanced by wind stress and regional (>100 km) pressure gradient force. In addition, a numerical model using an idealized SFCR bathymetry, forced by our observed winds, was employed to compare the momentum balance relationships identified by the data and those under steady-state conditions published earlier (Warner et al., 2014). A synthesis of the numerical and experimental data revealed that the true pressure gradient force results from the sum of local pressure gradient force, which maintains a Bernoulli-like relationship with alongshore advective acceleration, and regional pressure gradient force, which maintains a strong, negative relationship with wind stress. The differences between steady-state and realistic conditions is mainly on the contributions of regional scale pressure gradients that develop under realistic conditions, and the reduced contribution of local scale pressure gradients which develop best under steady-state conditions. Our analysis indicates that current veering over ridge crests, a consistent occurrence, is a combination of a cross-shore gradient in the inconsistent relationship between local advective acceleration and pressure gradient and frictional-torque with the latter being the dominant mechanism under realistic forcing.

  8. BLDG. 29 - INTERIOR (CLOSEUP) - GONDOLA - MSC

    NASA Image and Video Library

    1966-01-01

    The new centrifuge at MSC, located in the Flight Acceleration Facility (FAF), Bldg. 29. The 50-ft. arm can swing the 3-man gondola to create G-Forces Astronauts will experience during liftoffs and re-entry conditions. MSC, HOUSTON, TX CN

  9. Molecular Interactions in the Replication of Mouse Hepatitis Virus

    DTIC Science & Technology

    1987-05-08

    viruses of vertebrate species which cause a variety of acute 1 2 Figure 1. Mouse hepatitis virus , strain A59. (a) Negative stain of a virion...coronaviruses and the human corona - virus 229E (Weiss and Leibowitz, 1981). Antigenic relationships. Coronaviruses fall into two main groups...rate zonal and isopycnic centrifugation on density gradients. The density of corona - viruses in sucrose is 1.16 to 1.18 g/ml. Virions contain RNA

  10. Relativistic centrifugal instability

    NASA Astrophysics Data System (ADS)

    Gourgouliatos, Konstantinos N.; Komissarov, Serguei S.

    2018-03-01

    Near the central engine, many astrophysical jets are expected to rotate about their axis. Further out they are expected to go through the processes of reconfinement and recollimation. In both these cases, the flow streams along a concave surface and hence, it is subject to the centrifugal force. It is well known that such flows may experience the centrifugal instability (CFI), to which there are many laboratory examples. The recent computer simulations of relativistic jets from active galactic nuclei undergoing the process of reconfinement show that in such jets CFI may dominate over the Kelvin-Helmholtz instability associated with velocity shear (Gourgouliatos & Komissarov). In this letter, we generalize the Rayleigh criterion for CFI in rotating fluids to relativistic flows using a heuristic analysis. We also present the results of computer simulations which support our analytic criterion for the case of an interface separating two uniformly rotating cylindrical flows. We discuss the difference between CFI and the Rayleigh-Taylor instability in flows with curved streamlines.

  11. Compressibility Effects on Particle-Fluid Interaction Force for Eulerian-Eulerian Simulations

    NASA Astrophysics Data System (ADS)

    Akiki, Georges; Francois, Marianne; Zhang, Duan

    2017-11-01

    Particle-fluid interaction forces are essential in modeling multiphase flows. Several models can be found in the literature based on empirical, numerical, and experimental results from various simplified flow conditions. Some of these models also account for finite Mach number effects. Using these models is relatively straightforward with Eulerian-Lagrangian calculations if the model for the total force on particles is used. In Eulerian-Eulerian simulations, however, there is the pressure gradient terms in the momentum equation for particles. For low Mach number flows, the pressure gradient force is negligible if the particle density is much greater than that of the fluid. For supersonic flows where a standing shock is present, even for a steady and uniform flow, it is unclear whether the significant pressure-gradient force should to be separated out from the particle force model. To answer this conceptual question, we perform single-sphere fully-resolved DNS simulations for a wide range of Mach numbers. We then examine whether the total force obtained from the DNS can be categorized into well-established models, such as the quasi-steady, added-mass, pressure-gradient, and history forces. Work sponsored by Advanced Simulation and Computing (ASC) program of NNSA and LDRD-CNLS of LANL.

  12. Turbulent convective heat transfer of methane at supercritical pressure in a helical coiled tube

    NASA Astrophysics Data System (ADS)

    Wang, Chenggang; Sun, Baokun; Lin, Wei; He, Fan; You, Yingqiang; Yu, Jiuyang

    2018-02-01

    The heat transfer of methane at supercritical pressure in a helically coiled tube was numerically investigated using the Reynolds Stress Model under constant wall temperature. The effects of mass flux ( G), inlet pressure ( P in) and buoyancy force on the heat transfer behaviors were discussed in detail. Results show that the light fluid with higher temperature appears near the inner wall of the helically coiled tube. When the bulk temperature is less than or approach to the pseudocritical temperature ( T pc ), the combined effects of buoyancy force and centrifugal force make heavy fluid with lower temperature appear near the outer-right of the helically coiled tube. Beyond the T pc , the heavy fluid with lower temperature moves from the outer-right region to the outer region owing to the centrifugal force. The buoyancy force caused by density variation, which can be characterized by Gr/ Re 2 and Gr/ Re 2.7, enhances the heat transfer coefficient ( h) when the bulk temperature is less than or near the T pc , and the h experiences oscillation due to the buoyancy force. The oscillation is reduced progressively with the increase of G. Moreover, h reaches its peak value near the T pc . Higher G could improve the heat transfer performance in the whole temperature range. The peak value of h depends on P in. A new correlation was proposed for methane at supercritical pressure convective heat transfer in the helical tube, which shows a good agreement with the present simulated results.

  13. Dynamic properties of polydisperse colloidal particles in the presence of thermal gradient studied by a modified Brownian dynamic model

    NASA Astrophysics Data System (ADS)

    Song, Dongxing; Jin, Hui; Jing, Dengwei; Wang, Xin

    2018-03-01

    Aggregation and migration of colloidal particles under the thermal gradient widely exists in nature and many industrial processes. In this study, dynamic properties of polydisperse colloidal particles in the presence of thermal gradient were studied by a modified Brownian dynamic model. Other than the traditional forces on colloidal particles, including Brownian force, hydrodynamic force, and electrostatic force from other particles, the electrostatic force from the asymmetric ionic diffusion layer under a thermal gradient has been considered and introduced into the Brownian dynamic model. The aggregation ratio of particles (R A), the balance time (t B) indicating the time threshold when {{R}A} becomes constant, the porosity ({{P}BA} ), fractal dimension (D f) and distributions of concentration (DISC) and aggregation (DISA) for the aggregated particles were discussed based on this model. The aggregated structures formed by polydisperse particles are less dense and the particles therein are loosely bonded. Also it showed a quite large compressibility as the increases of concentration and interparticle potential can significantly increase the fractal dimension. The thermal gradient can induce two competitive factors leading to a two-stage migration of particles. When t<{{t}B} , the unsynchronized aggregation is dominant and the particles slightly migrate along the thermal gradient. When t>{{t}B} , the thermophoresis becomes dominant thus the migrations of particles are against the thermal gradient. The effect of thermophoresis on the aggregate structures was found to be similar to the effect of increasing particle concentration. This study demonstrates how the thermal gradient affects the aggregation of monodisperse and polydisperse particles and can be a guide for the biomimetics and precise control of colloid system under the thermal gradient. Moreover, our model can be easily extended to other more complex colloidal systems considering shear, temperature fluctuation, surfactant, etc.

  14. Pitch-Plane Angular Displacement Perception During Helicopter Flight and Gondola Centrifugation.

    PubMed

    Tribukait, Arne; Bergsten, Eddie; Eiken, Ola

    During hovering with a helicopter, an involuntary change in attitude (during brownout) results in reduced lifting force and a horizontal acceleration component. This movement pattern is difficult to perceive via the otolith organs. If the angular displacement occurs rapidly, it will, however, activate the semicircular canals. The major aim of this study was to establish to what extent pitch-plane angular displacements can be perceived based on canal information when there is no tilt stimulus to the otoliths. In a helicopter, 9 nonpilots (N) and 8 helicopter pilots (P) underwent 5-6 pitch-forward displacements (magnitude 14-33°, angular velocity 2-7° · s -1 ). In a swing-out gondola centrifuge, 9 N and 3 P were exposed to a similar canal-otolith conflict (acceleration, seated centripetally) with four displacements of 25° and two of 60°. The visually perceived eye level (VPEL) was continuously recorded using an adjustable luminous dot in darkness. For each helicopter dive and centrifuge run the gain was calculated as the ratio (VPEL deflection)/(displacement of helicopter or gondola). In the helicopter there was no difference between N (0.28 ± 0.13) and P (0.36 ± 0.22). In the centrifuge the gains were 0.34 ± 0.18° (25° displacements) and 0.30 ± 0.16° (60° displacements). Values obtained in the helicopter did not differ significantly from those in the centrifuge. There was a correlation between data obtained during the 25° and 60° displacements in the centrifuge. There was a pronounced underestimation of pitch angular displacements in a helicopter. The interindividual variability was considerable. Gains for perceived displacement were similar in helicopter and centrifuge. Tribukait A, Bergsten E, Eiken O. Pitch-plane angular displacement perception during helicopter flight and gondola centrifugation. Aerosp Med Hum Perform. 2016; 87(10):852-861.

  15. Ceramic blade attachment system

    DOEpatents

    Boyd, Gary L.

    1995-01-01

    A retainer ring is arranged to mount turbine blades to a turbine disk so that aerodynamic forces produced by a gas turbine engine are transferred from the turbine blades to the turbine disk to cause the turbine blades and turbine disk to rotate, but so that centrifugal forces of the turbine blades resulting from the rotation of the turbine blades and turbine disk are not transferred from the turbine blades to the turbine disk.

  16. Proposition of stair climb of a drop using chemical wettability gradient

    NASA Astrophysics Data System (ADS)

    Seerha, Prabh P. S.; Kumar, Parmod; Das, Arup K.; Mitra, Sushanta K.

    2017-07-01

    We propose a passive technique for a drop to climb along the staircase textured surface using chemical wettability gradients. The stair structure, droplet configuration, and contact angle gradient are modeled using Lagrangian smoothed particle hydrodynamics. The stair climb efficiency of the droplet is found to be a function of wettability gradient strength. Using analytical balance of actuation and resistive forces across droplets, physical reasons behind stair climbing are established and influencing parameters are identified. Evolution of the droplet shape along with the advancing and the receding contact angles is presented from where instantaneous actuation and hysteresis forces are calculated. Using history of Lagrangian particles, circulation at the foot of stairs and progressing development of the advancing drop front are monitored. Higher efficiency in stair climbing in the case of a bigger sized drop than smaller one is obtained from simulation results and realized from force balance. Difficulty in climbing steeper stairs is also demonstrated to delineate the effect of gravitational pull against the actuation force due to the wettability gradient.

  17. Decrease in T Cell Activation and Calcium Flux during Clinorotation

    NASA Technical Reports Server (NTRS)

    Sams, Clarence; Holtzclaw, J. David

    2006-01-01

    We investigated the effect of altered gravitational environments on T cell activation. We isolated human, naive T cells (CD3+CD14-CD19-CD16-CD56-CD25-CD69-CD45RA-) following IRB approved protocols. These purified T cells were then incubated with 6 mm polystyrene beads coated with OKT3 (Ortho Biotech, Raritan, NJ) and antiCD28 (Becton Dickinson (BD), San Jose, CA) at 37 C for 24 hours. Antibodies were at a 1:1 ratio and the bead-to-cell ratio was 2:1. Four incubation conditions existed: 1) static or "1g"; 2) centrifugation at 10 relative centrifugal force (RCF) or "10g"; 3) clinorotation at 25 RPM (functional weightlessness or "0g"); and 4) clinorotation at 80 RPM ("1g" plus net shear force approx.30 dynes/sq cm). Following incubation, T cells were stained for CD25 expression (BD) and intracellular calcium (ratio of Fluo4 to Fura Red, Molecular Probes, Eugene, OR) and analyzed by flow cytometry (Coulter EPICS XL, Miami, FL). Results: Static or "1g" T cells had the highest level of CD25 expression and intracellular calcium. T cells centrifuged at 10 RCF ("10g") had lower CD25 expression and calcium levels compared to the static control. However, cells centrifuged at 10 RCF had higher CD25 expression and calcium levels than those exposed to 24 RPM clinorotation ("0g"). T cells exposed to 24 RPM clinorotation had lower CD25 expression, but the approximately the same calcium levels than T cells exposed to 80 RPM clinorotation. These data suggest that stress-activated calcium channel exist in T cells and may play a role during T cell activation.

  18. Artificial Gravity as a Multi-System Countermeasure to Bed Rest Deconditioning: Preliminary Results

    NASA Technical Reports Server (NTRS)

    Warren, L. E.; Paloski, William H.; Young, L. R.

    2006-01-01

    Artificial gravity paradigms may offer effective, efficient, multi-system protection from the untoward effects of adaptation to the microgravity of space or the hypogravity of planetary surfaces. Intermittent artificial gravity (AG) produced by a horizontal short-radius centrifuge (SRC) has recently been utilized on human test subjects deconditioned by bed rest. This presentation will review preliminary results of a 41 day study conducted at the University of Texas Medical Branch, Galveston, TX bed rest facility. During the first eleven days of the protocol, subjects were ambulatory, but confined to the facility. They began a carefully controlled diet, and participated in multiple baseline tests of bone, muscle, cardiovascular, sensory-motor, immunological, and psychological function. On the twelfth day, subjects entered the bed rest phase of the study, during which they were confined to strict 6deg head down tilt bed rest for 21 days. Beginning 24 hrs into this period, treatment subjects received one hour daily exposures to artificial gravity which was produced by spinning the subjects on a 3.0 m radius SRC. They were oriented radially in the supine position so that the centrifugal force was aligned with their long body axis, and while spinning, they "stood" on a force plate, supporting the centrifugal loading (2.5 g at the feet, 1.0 g at the heart). The subject station allowed free translation over approximately 10 cm to ensure full loading of the lower extremities and to allow for anti-orthostatic muscle contractions. Control subjects were positioned on the centrifuge but did not spin. Following the bed rest phase, subjects were allowed to ambulate again, but remained within the facility for an additional 9 days and participated in multiple follow-up tests of physiological function.

  19. Thirty Stage Annular Centrifugal Contactor Thermal Profile Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    David H. Meikrantz; Troy G. Garn; Jack D. Law

    2010-02-01

    A thirty stage 5 cm annular centrifugal contactor cascade has been assembled and tested to obtain thermal profiles during both ambient and heated input conditions of operation. Thermocouples were installed on every stage as well as feed inputs and Real-time data was taken during experiments lasting from two to eight hours at total flow rates of 0.5 to 1.4 liters per minute. Ambient temperature profile results show that only a small amount of heat is generated by the mechanical energy of the contactors. Steady state temperature profiles mimic the ambient temperature of the lab but are higher toward the middlemore » of the cascade. Heated inlet solutions gave temperature profiles with smaller temperature gradients, more driven by the temperature of the inlet solutions than ambient lab temperature. Temperature effects of solution mixing, even at rotor speeds of 4000 rpm, were not measurable.« less

  20. A dawn to dusk electric field in the Jovian magnetosphere

    NASA Technical Reports Server (NTRS)

    Goertz, C. K.; Ip, W. I.

    1983-01-01

    It is shown that if Io-injected plasma is lost via a planetary wind-fixed Birkeland current system may result. This is due to the fact that the azimuthal centrifugal current flows across a density gradient produced by the loss of plasma through the planetary wind in the tail. The divergent centrifugal current is connected to field-aligned Birkeland currents which flow into the ionosphere at dawn and out of it at dusk. The closure currents in the ionosphere require a dawn to dusk electric field which at the orbit of Io is estimated to have a strength of 0.2 mV/m. However, the values of crucial parameters are not well known and the field at Io's orbit may well be significantly larger. Independent estimates derived from the local time asymmetry of the torus UV emission indicate a field of 1.5 mV/m.

  1. Liquid-chromatographic determination of sarafloxacin residues in channel catfish muscle-tissue

    USGS Publications Warehouse

    Meinertz, J.R.; Dawson, V.K.; Gingerich, W.H.; Cheng, B.; Tubergen, M.M.

    1994-01-01

    A liquid chromatographic method is described for the determination of sarafloxacin hydrochloride residues i n channel catfish (ictalurus punctatus) fillets. Sarafloxacin was extracted from fillet tissue with acetonitrile=water (1 + 1). The extract was centrifuged and the supernatant was partitioned with hexane. The aqueous fraction was filtered through a 0.45 Mum filter and evaporated to dryness. The sample was redissolved with 20% acetonitrile-methanol (3 + 2) and 80% trifluoroacetic acid (0.1%), Centrifuged, and filtered to remove proteins. Samples were analyzed by chromatography with gradient elution on a c18 column and with fluorescence detection (excitation at 280 nm and emission above 389 nm). Mean recoveries ranged from 85.4 To 104%, and relative standard deviations ranged from 1.06 To 5.58% In samples spiked at concentrations of 10.0-863.8 Ng/g. The method detection limit for sarafloxacin was 1.4 Ng/g.

  2. Physical, Chemical, Bibological, and Biotechnological sciences are incomplete without each other

    USDA-ARS?s Scientific Manuscript database

    By coupling of mechanics, optics, and mathematics, Theodor Svedberg invented the ultracentrifuge, which allowed separation of important biological materials by high centrifugal force, resulting in physical chemical separation and characterization of atherogenic low density lipoproteins and other bio...

  3. Different patterns of metabolic cryo-damage in domestic cat (Felis catus) and cheetah (Acinonyx jubatus) spermatozoa.

    PubMed

    Terrell, Kimberly A; Wildt, David E; Anthony, Nicola M; Bavister, Barry D; Leibo, S P; Penfold, Linda M; Marker, Laurie L; Crosier, Adrienne E

    2012-04-01

    Felid spermatozoa are sensitive to cryopreservation-induced damage, but functional losses can be mitigated by post-thaw swim-up or density gradient processing methods that selectively recover motile or structurally-normal spermatozoa, respectively. Despite the importance of sperm energy production to achieving fertilization, there is little knowledge about the influence of cryopreservation or post-thaw processing on felid sperm metabolism. We conducted a comparative study of domestic cat and cheetah sperm metabolism after cryopreservation and post-thaw processing. We hypothesized that freezing/thawing impairs sperm metabolism and that swim-up, but not density gradient centrifugation, recovers metabolically-normal spermatozoa. Ejaculates were cryopreserved, thawed, and processed by swim-up, Accudenz gradient centrifugation, or conventional washing (representing the 'control'). Sperm glucose and pyruvate uptake, lactate production, motility, and acrosomal integrity were assessed. Mitochondrial membrane potential (MMP) was measured in cat spermatozoa. In both species, lactate production, motility, and acrosomal integrity were reduced in post-thaw, washed samples compared to freshly-collected ejaculates. Glucose uptake was minimal pre- and post-cryopreservation, whereas pyruvate uptake was similar between treatments due to high coefficients of variation. In the cat, swim-up, but not Accudenz processing, recovered spermatozoa with increased lactate production, pyruvate uptake, and motility compared to controls. Although confounded by differences in non-specific fluorescence among processing methods, MMP values within treatments were positively correlated to sperm motility and acrosomal integrity. Cheetah spermatozoa isolated by either selection method exhibited improved motility and/or acrosomal integrity, but remained metabolically compromised. Collectively, findings revealed a metabolically-robust subpopulation of cryopreserved cat, but not cheetah, spermatozoa, recovered by selecting for motility rather than morphology. Published by Elsevier Inc.

  4. Proteomic Analysis of Detergent-resistant Membrane Microdomains in Trophozoite Blood Stage of the Human Malaria Parasite Plasmodium falciparum*

    PubMed Central

    Yam, Xue Yan; Birago, Cecilia; Fratini, Federica; Di Girolamo, Francesco; Raggi, Carla; Sargiacomo, Massimo; Bachi, Angela; Berry, Laurence; Fall, Gamou; Currà, Chiara; Pizzi, Elisabetta; Breton, Catherine Braun; Ponzi, Marta

    2013-01-01

    Intracellular pathogens contribute to a significant proportion of infectious diseases worldwide. The successful strategy of evading the immune system by hiding inside host cells is common to all the microorganism classes, which exploit membrane microdomains, enriched in cholesterol and sphingolipids, to invade and colonize the host cell. These assemblies, with distinct biochemical properties, can be isolated by means of flotation in sucrose density gradient centrifugation because they are insoluble in nonionic detergents at low temperature. We analyzed the protein and lipid contents of detergent-resistant membranes from erythrocytes infected by Plasmodium falciparum, the most deadly human malaria parasite. Proteins associated with membrane microdomains of trophic parasite blood stages (trophozoites) include an abundance of chaperones, molecules involved in vesicular trafficking, and enzymes implicated in host hemoglobin degradation. About 60% of the identified proteins contain a predicted localization signal suggesting a role of membrane microdomains in protein sorting/trafficking. To validate our proteomic data, we raised antibodies against six Plasmodium proteins not characterized previously. All the selected candidates were recovered in floating low-density fractions after density gradient centrifugation. The analyzed proteins localized either to internal organelles, such as the mitochondrion and the endoplasmic reticulum, or to exported membrane structures, the parasitophorous vacuole membrane and Maurer's clefts, implicated in targeting parasite proteins to the host erythrocyte cytosol or surface. The relative abundance of cholesterol and phospholipid species varies in gradient fractions containing detergent-resistant membranes, suggesting heterogeneity in the lipid composition of the isolated microdomain population. This study is the first report showing the presence of cholesterol-rich microdomains with distinct properties and subcellular localization in trophic stages of Plasmodium falciparum. PMID:24045696

  5. Developmental anatomy and immunocytochemistry reveal the neo-ontogenesis of the leaf tissues of Psidium myrtoides (Myrtaceae) towards the globoid galls of Nothotrioza myrtoidis (Triozidae).

    PubMed

    Carneiro, Renê G S; Oliveira, Denis C; Isaias, Rosy M S

    2014-12-01

    The temporal balance between hyperplasia and hypertrophy, and the new functions of different cell lineages led to cell transformations in a centrifugal gradient that determines the gall globoid shape. Plant galls develop by the redifferentiation of new cell types originated from those of the host plants, with new functional and structural designs related to the composition of cell walls and cell contents. Variations in cell wall composition have just started to be explored with the perspective of gall development, and are herein related to the histochemical gradients previously detected on Psidium myrtoides galls. Young and mature leaves of P. myrtoides and galls of Nothotrioza myrtoidis at different developmental stages were analysed using anatomical, cytometrical and immunocytochemical approaches. The gall parenchyma presents transformations in the size and shape of the cells in distinct tissue layers, and variations of pectin and protein domains in cell walls. The temporal balance between tissue hyperplasia and cell hypertrophy, and the new functions of different cell lineages led to cell transformations in a centrifugal gradient, which determines the globoid shape of the gall. The distribution of cell wall epitopes affected cell wall flexibility and rigidity, towards gall maturation. By senescence, it provided functional stability for the outer cortical parenchyma. The detection of the demethylesterified homogalacturonans (HGAs) denoted the activity of the pectin methylesterases (PMEs) during the senescent phase, and was a novel time-based detection linked to the increased rigidity of the cell walls, and to the gall opening. Current investigation firstly reports the influence of immunocytochemistry of plant cell walls over the development of leaf tissues, determining their neo-ontogenesis towards a new phenotype, i.e., the globoid gall morphotype.

  6. Longwave emission trends over Africa and implications for Atlantic hurricanes

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Rechtman, Thomas; Karnauskas, Kristopher B.; Li, Laifang; Donnelly, Jeffrey P.; Kossin, James P.

    2017-09-01

    The latitudinal gradient of outgoing longwave radiation (OLR) over Africa is a skillful and physically based predictor of seasonal Atlantic hurricane activity. The African OLR gradient is observed to have strengthened during the satellite era, as predicted by state-of-the-art global climate models (GCMs) in response to greenhouse gas forcing. Prior to the satellite era and the U.S. and European clean air acts, the African OLR gradient weakened due to aerosol forcing of the opposite sign. GCMs predict a continuation of the increasing OLR gradient in response to greenhouse gas forcing. Assuming a steady linear relationship between African easterly waves and tropical cyclogenesis, this result suggests a future increase in Atlantic tropical cyclone frequency by 10% (20%) at the end of the 21st century under the RCP 4.5 (8.5) forcing scenario.

  7. Vertical hydraulic conductivity of a clayey-silt aquitard: accelerated fluid flow in a centrifuge permeameter compared with in situ conditions

    NASA Astrophysics Data System (ADS)

    Timms, W. A.; Crane, R.; Anderson, D. J.; Bouzalakos, S.; Whelan, M.; McGeeney, D.; Rahman, P. F.; Guinea, A.; Acworth, R. I.

    2014-03-01

    Evaluating the possibility of leakage through low permeability geological strata is critically important for sustainable water supplies, extraction of fuels from strata such as coal beds, and confinement of waste within the earth. Characterizing low or negligible flow rates and transport of solutes can require impractically long periods of field or laboratory testing, but is necessary for evaluations over regional areas and over multi-decadal timescales. The current work reports a custom designed centrifuge permeameter (CP) system, which can provide relatively rapid and reliable hydraulic conductivity (K) measurement compared to column permeameter tests at standard gravity (1g). Linear fluid velocity through a low K porous sample is linearly related to g-level during a CP flight unless consolidation or geochemical reactions occur. The CP module is designed to fit within a standard 2 m diameter, geotechnical centrifuge with a capacity for sample dimensions of 30 to 100 mm diameter and 30 to 200 mm in length. At maximum RPM the resultant centrifugal force is equivalent to 550g at base of sample or a total stress of ~2 MPa. K is calculated by measuring influent and effluent volumes. A custom designed mounting system allows minimal disturbance of drill core samples and a centrifugal force that represents realistic in situ stress conditions is applied. Formation fluids were used as influent to limit any shrink-swell phenomena which may alter the resultant K value. Vertical hydraulic conductivity (Kv) results from CP testing of core from the sites in the same clayey silt formation varied (10-7 to 10-9 m s-1, n = 14) but higher than 1g column permeameter tests of adjacent core using deionized water (10-9 to 10-11 m s-1, n = 7). Results at one site were similar to in situ Kv values (3 × 10-9 m s-1) from pore pressure responses within a 30 m clayey sequence in a homogenous area of the formation. Kv sensitivity to sample heterogeneity was observed, and anomalous flow via preferential pathways could be readily identified. Results demonstrate the utility of centrifuge testing for measuring minimum K values that can contribute to assessments of geological formations at large scale. The importance of using realistic stress conditions and influent geochemistry during hydraulic testing is also demonstrated.

  8. Numerical simulation of unmanned aerial vehicle under centrifugal load and optimization of milling and planing

    NASA Astrophysics Data System (ADS)

    Chen, Yunsheng; Lu, Xinghua

    2018-05-01

    The mechanical parts of the fuselage surface of the UAV are easily fractured by the action of the centrifugal load. In order to improve the compressive strength of UAV and guide the milling and planing of mechanical parts, a numerical simulation method of UAV fuselage compression under centrifugal load based on discrete element analysis method is proposed. The three-dimensional discrete element method is used to establish the splitting tensile force analysis model of the UAV fuselage under centrifugal loading. The micro-contact connection parameters of the UAV fuselage are calculated, and the yield tensile model of the mechanical components is established. The dynamic and static mechanical model of the aircraft fuselage milling is analyzed by the axial amplitude vibration frequency combined method. The correlation parameters of the cutting depth on the tool wear are obtained. The centrifugal load stress spectrum of the surface of the UAV is calculated. The meshing and finite element simulation of the rotor blade of the unmanned aerial vehicle is carried out to optimize the milling process. The test results show that the accuracy of the anti - compression numerical test of the UAV is higher by adopting the method, and the anti - fatigue damage capability of the unmanned aerial vehicle body is improved through the milling and processing optimization, and the mechanical strength of the unmanned aerial vehicle can be effectively improved.

  9. Effect of passengers' active head tilt and opening/closure of eyes on motion sickness in lateral acceleration environment of cars.

    PubMed

    Wada, Takahiro; Yoshida, Keigo

    2016-08-01

    This study examined the effect of passengers' active head-tilt and eyes-open/eyes-closed conditions on the severity of motion sickness in the lateral acceleration environment of cars. In the centrifugal head-tilt condition, participants intentionally tilted their heads towards the centrifugal force, whereas in the centripetal head-tilt condition, the participants tilted their heads against the centrifugal acceleration. The eyes-open and eyes-closed cases were investigated for each head-tilt condition. In the experimental runs, the sickness rating in the centripetal head-tilt condition was significantly lower than that in the centrifugal head-tilt condition. Moreover, the sickness rating in the eyes-open condition was significantly lower than that in the eyes-closed condition. The results suggest that an active head-tilt motion against the centrifugal acceleration reduces the severity of motion sickness both in the eyes-open and eyes-closed conditions. They also demonstrate that the eyes-open condition significantly reduces the motion sickness even when the head-tilt strategy is used. Practitioner Summary: Little is known about the effect of head-tilt strategies on motion sickness. This study investigated the effects of head-tilt direction and eyes-open/eyes-closed conditions on motion sickness during slalom automobile driving. Passengers' active head tilt towards the centripetal direction and the eyes-open condition greatly reduce the severity of motion sickness.

  10. The perception of roll tilt in pilots during a simulated coordinated turn in a gondola centrifuge.

    PubMed

    Tribukait, Arne; Grönkvist, Mikael; Eiken, Ola

    2011-05-01

    It has previously been reported that nonpilots underestimate the roll tilt angle after acceleration in a gondola centrifuge. The aim of the present work was to elucidate the significance of flight experience for roll tilt perception based on vestibular information. The subjective visual horizontal (SVH) was measured by means of an adjustable luminous line in darkness. Eight nonpilots (N), nine fighter pilots (F), and eight helicopter pilots (H) underwent two centrifuge runs (2 G, 5 min) heading forward and backward, respectively. The roll position of the gondola (60 degrees at 2 G) was controlled so that the subject was always upright with respect to the gravitoinertial force. Upon acceleration of the centrifuge there was a tilt of the SVH in a direction compensatory to the inclination of the gondola. This tilt was larger in the forward position [N: 17.2 +/- 6.4 degrees, F: 31.2 +/- 16.4 degrees, H: 33.6 +/- 18.2 degrees (means +/- SD)] than in the backward position (N: -5.0 +/- 6.8 degrees, F: -12.2 +/- 17.4 degrees, H: -10.4 +/- 15.4 degrees). In N the tilt declined with time, approaching zero by the end of the 2-G plateau. In the pilots it was significantly larger and did not decline. Flight experience results in an increased ability to perceive the roll tilt during movement along a curved path. That this can be revealed in a centrifuge might suggest that acceleration of the centrifuge constitutes a movement pattern which is similar, from a vestibular point of view, to that of an airplane entering a coordinated turn.

  11. Magnetic Control of Concentration Gradient in Microgravity

    NASA Technical Reports Server (NTRS)

    Leslie, Fred; Ramachandran, Narayanan

    2005-01-01

    A report describes a technique for rapidly establishing a fluid-concentration gradient that can serve as an initial condition for an experiment on solutal instabilities associated with crystal growth in microgravity. The technique involves exploitation of the slight attractive or repulsive forces exerted on most fluids by a magnetic-field gradient. Although small, these forces can dominate in microgravity and therefore can be used to hold fluids in position in preparation for an experiment. The magnetic field is applied to a test cell, while a fluid mixture containing a concentration gradient is prepared by introducing an undiluted solution into a diluting solution in a mixing chamber. The test cell is then filled with the fluid mixture. Given the magnetic susceptibilities of the undiluted and diluting solutions, the magnetic-field gradient must be large enough that the magnetic force exceeds both (1) forces associated with the flow of the fluid mixture during filling of the test cell and (2) forces imposed by any residual gravitation and fluctuations thereof. Once the test cell has been filled with the fluid mixture, the magnetic field is switched off so that the experiment can proceed, starting from the proper initial conditions.

  12. Propelling Extended Objects

    NASA Astrophysics Data System (ADS)

    Humbert, Richard

    2010-03-01

    A force acting on just part of an extended object (either a solid or a volume of a liquid) can cause all of it to move. That motion is due to the transmission of the force through the object by its material. This paper discusses how the force is distributed to all of the object by a gradient of stress or pressure in it, which creates the local force that directly propels each part of the object. Those gradients resemble the ones created in objects by their weights. An example of the latter is the compressive stress in a column of a building increasing steadily toward its lower end. That gradient occurs because each horizontal section through the column supports all of the weight above it, including the load force pushing down on the column's upper end. The gradient resembles the pressure in a container of liquid increasing with depth in it. Likewise, the weight of a vertically hanging cable causes its tension and tensile stress to increase toward its upper end.

  13. A magnetic gradient induced force in NMR restricted diffusion experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghadirian, Bahman; Stait-Gardner, Tim; Castillo, Reynaldo

    2014-03-28

    We predict that the phase cancellation of a precessing magnetisation field carried by a diffusing species in a bounded geometry under certain nuclear magnetic resonance pulsed magnetic field gradient sequences results in a small force over typically micrometre length scales. Our calculations reveal that the total magnetisation energy in a pore under the influence of a pulsed gradient will be distance-dependent thus resulting in a force acting on the boundary. It is shown that this effect of the magnetisation of diffusing particles will appear as either an attractive or repulsive force depending on the geometry of the pore and magneticmore » properties of the material. A detailed analysis is performed for the case of a pulsed gradient spin-echo experiment on parallel planes. It is shown that the force decays exponentially in terms of the spin-spin relaxation. The proof is based on classical electrodynamics. An application of this effect to soft matter is suggested.« less

  14. Quantification of platelets and platelet derived growth factors from platelet-rich-plasma (PRP) prepared at different centrifugal force (g) and time.

    PubMed

    Arora, Satyam; Doda, Veena; Kotwal, Urvershi; Dogra, Mitu

    2016-02-01

    Platelet derived biomaterials represent a key source of cytokines and growth factors extensively used for tissue regeneration; wound healing and tissue repair. Our study was to quantify platelets and growth factors released by PRP when prepared at different centrifugal force (g) and time. Our study was approved by the institutional ethical committee. One hundred millilitres of whole blood (WB) was collected in bag with CPDA as the anticoagulant(AC); (14 mL for 100 mL WB ratio). Nine aliquots of 10 mL each were made from the bag and set of three aliquots were made a group. PRP was prepared at varying centrifugal force (group A: -110 g, group B: -208 g & group C: -440 g) & time (1: -5 min, 2: -10 min & 3: -20 min). Contents of each PRP prepared were analysed. Commercial sandwich ELISA kits were used to quantify the concentrations of CD62P (Diaclone SAS; France), Platelet derived growth factors-AB (Qayee-Bio; China), transforming growth factor-β1 (DRG; Germany) and vascular endothelial growth factor (Boster Immuno Leader; USA) released in each PRP prepared. Eight volunteers were enrolled in the study (24-30 years). The baseline blood counts of all the volunteers were comparable (p ≥ 0.05). Mean ± SD of platelet yield of all nine groups ranged from 17.2 ± 4.2% to 78.7 ± 5.7%. Each PRP was activated with calcified thromboplastin to quantify the growth factors released by them. Significantly higher (p < 0.05) transforming growth factor-β1 and vascular endothelial growth factor were released compared to the baseline. Our study highlights the variation in both force (g) and time results in changes at cellular level and growth factor concentrations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Motion in a modified Chermnykh's restricted three-body problem with oblateness

    NASA Astrophysics Data System (ADS)

    Singh, Jagadish; Leke, Oni

    2014-03-01

    In this paper, the restricted problem of three bodies is generalized to include a case when the passively gravitating test particle is an oblate spheroid under effect of small perturbations in the Coriolis and centrifugal forces when the first primary is a source of radiation and the second one an oblate spheroid, coupled with the influence of the gravitational potential from the belt. The equilibrium points are found and it is seen that, in addition to the usual three collinear equilibrium points, there appear two new ones due to the potential from the belt and the mass ratio. Two triangular equilibrium points exist. These equilibria are affected by radiation of the first primary, small perturbation in the centrifugal force, oblateness of both the test particle and second primary and the effect arising from the mass of the belt. The linear stability of the equilibrium points is explored and the stability outcome of the collinear equilibrium points remains unstable. In the case of the triangular points, motion is stable with respect to some conditions which depend on the critical mass parameter; influenced by the small perturbations, radiating effect of the first primary, oblateness of the test body and second primary and the gravitational potential from the belt. The effects of each of the imposed free parameters are analyzed. The potential from the belt and small perturbation in the Coriolis force are stabilizing parameters while radiation, small perturbation in the centrifugal force and oblateness reduce the stable regions. The overall effect is that the region of stable motion increases under the combine action of these parameters. We have also found the frequencies of the long and short periodic motion around stable triangular points. Illustrative numerical exploration is rendered in the Sun-Jupiter and Sun-Earth systems where we show that in reality, for some values of the system parameters, the additional equilibrium points do not in general exist even when there is a belt to interact with.

  16. The International Society for Extracellular Vesicles launches the first massive open online course on extracellular vesicles.

    PubMed

    Lässer, Cecilia; Théry, Clotilde; Buzás, Edit I; Mathivanan, Suresh; Zhao, Weian; Gho, Yong Song; Lötvall, Jan

    2016-01-01

    The International Society for Extracellular Vesicles (ISEV) has organised its first educational online course for students and beginners in the field of extracellular vesicles (EVs). This course, "Basics of Extracellular Vesicles," uses recorded lectures from experts in the field and will be open for an unlimited number of participants. The course is divided into 5 modules and can be accessed at www.coursera.org/learn/extracellular-vesicles. The first module is an introduction to the field covering the nomenclature and history of EVs. Module 2 focuses on the biogenesis and uptake mechanisms of EVs, as well as their RNA, protein and lipid cargo. Module 3 covers the collection and processing of cell culture media and body fluids such as blood, breast milk, cerebrospinal fluid and urine prior to isolation of EVs. Modules 4 and 5 present different isolation methods and characterisation techniques utilised in the EV field. Here, differential ultracentrifugation, size-exclusion chromatography, density gradient centrifugation, kit-based precipitation, electron microscopy, cryo-electron microscopy, flow cytometry, atomic-force microscopy and nanoparticle-tracking analysis are covered. This first massive open online course (MOOC) on EVs was launched on 15 August 2016 at the platform "Coursera" and is free of charge.

  17. AFRRI (Armed Forces Radiobiology Research Institute) reports, October, January-March 1989. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-01-01

    Contents include: effects of ethiofos (WR-2721) and radiation on monkey visual discrimination performance; gamma radiolysis of RNA: an ESR and spin-trapping study; phospholipid storage in the secretory granule of the mast cell; physiological localization of an agonist-sensitive pool of Ca{sup 2+} in parotid acinar cells; changes in canine neutrophil function(s) following cellular isolation by percoll gradient centrifugation or isotoniclysis; impaired repair of uvc-induced DNA damage in l5178Y-R cells: sedimentation studies with the use of 5'-bromodeoxyuridine photolysis; comparative behavioral toxicity of four sulfhydryl radioprotective compounds in mice: WR-2721, cysteamine, diethyldithiocarbamate, and n-acetylcysteine; measurement of the radiosensitivity of rat marrow by flowmore » cytometry; radioprotection by biological response modifiers alone and in combination with WR-2721; postirradiation glucan administration enhances the radioprotective effects of WR-2721; attenuation and cross-attenuation in taste aversion learning in the rat: studies with ionizing radiation, lithium chloride, and ethanol; a low-energy x-ray irradiator for electrophysiological studies; thermospray liquid chromatography mass spectrometry of thiol radioprotective agents: characteristic spectra; radioprotection by leukotrienes: is there a receptor mechanism and a low-energy x-ray irradiator for electrophysiological studies.« less

  18. Residual matrix from different separation techniques impacts exosome biological activity.

    PubMed

    Paolini, Lucia; Zendrini, Andrea; Di Noto, Giuseppe; Busatto, Sara; Lottini, Elisabetta; Radeghieri, Annalisa; Dossi, Alessandra; Caneschi, Andrea; Ricotta, Doris; Bergese, Paolo

    2016-03-24

    Exosomes are gaining a prominent role in research due to their intriguing biology and several therapeutic opportunities. However, their accurate purification from body fluids and detailed physicochemical characterization remain open issues. We isolated exosomes from serum of patients with Multiple Myeloma by four of the most popular purification methods and assessed the presence of residual contaminants in the preparations through an ad hoc combination of biochemical and biophysical techniques - including Western Blot, colloidal nanoplasmonics, atomic force microscopy (AFM) and scanning helium ion microscopy (HIM). The preparations obtained by iodixanol and sucrose gradients were highly pure. To the contrary, those achieved with limited processing (serial centrifugation or one step precipitation kit) resulted contaminated by a residual matrix, embedding the exosomes. The contaminated preparations showed lower ability to induce NfkB nuclear translocation in endothelial cells with respect to the pure ones, probably because the matrix prevents the interaction and fusion of the exosomes with the cell membrane. These findings suggest that exosome preparation purity must be carefully assessed since it may interfere with exosome biological activity. Contaminants can be reliably probed only by an integrated characterization approach aimed at both the molecular and the colloidal length scales.

  19. REVIEWS OF TOPICAL PROBLEMS: Free convection in geophysical processes

    NASA Astrophysics Data System (ADS)

    Alekseev, V. V.; Gusev, A. M.

    1983-10-01

    A highly significant geophysical process, free convection, is examined. Thermal convection often controls the dynamical behavior in several of the earth's envelopes: the atmosphere, ocean, and mantle. Section 2 sets forth the thermohydrodynamic equations that describe convection in a compressible or incompressible fluid, thermochemical convection, and convection in the presence of thermal diffusion. Section 3 reviews the mechanisms for the origin of the global atmospheric and oceanic circulation. Interlatitudinal convection and jet streams are discussed, as well as monsoon circulation and the mean meridional circulation of ocean waters due to the temperature and salinity gradients. Also described are the hypotheses for convective motion in the mantle and the thermal-wave (moving flame) mechanism for inducing global circulation (the atmospheres of Venus and Mars provide illustrations). Eddy formation by convection in a centrifugal force field is considered. Section 4 deals with medium- and small-scale convective processes, including hurricane systems with phase transitions, cellular cloud structure, and convection penetrating into the ocean, with its stepped vertical temperature and salinity microstructure. Self-oscillatory processes involving convection in fresh-water basins are discussed, including effects due to the anomalous (p,T) relation for water.

  20. Morphologic and proteomic characterization of exosomes released by cultured extravillous trophoblast cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atay, Safinur; Gercel-Taylor, Cicek; Kesimer, Mehmet

    Exosomes represent an important intercellular communication vehicle, mediating events essential for the decidual microenvironment. While we have demonstrated exosome induction of pro-inflammatory cytokines, to date, no extensive characterization of trophoblast-derived exosomes has been provided. Our objective was to provide a morphologic and proteomic characterization of these exosomes. Exosomes were isolated from the conditioned media of Swan71 human trophoblast cells by ultrafiltration and ultracentrifugation. These were analyzed for density (sucrose density gradient centrifugation), morphology (electron microscopy), size (dynamic light scattering) and protein composition (Ion Trap mass spectrometry and western immunoblotting). Based on density gradient centrifugation, microvesicles from Sw71 cells exhibit amore » density between 1.134 and 1.173 g/ml. Electron microscopy demonstrated that microvesicles from Sw71 cells exhibit the characteristic cup-shaped morphology of exosomes. Dynamic light scattering showed a bell-shaped curve, indicating a homogeneous population with a mean size of 165 nm {+-} 0.5 nm. Ion Trap mass spectrometry demonstrated the presence of exosome marker proteins (including CD81, Alix, cytoskeleton related proteins, and Rab family). The MS results were confirmed by western immunoblotting. Based on morphology, density, size and protein composition, we defined the release of exosomes from extravillous trophoblast cells and provide their first extensive characterization. This characterization is essential in furthering our understanding of 'normal' early pregnancy.« less

  1. Sonication-based isolation and enrichment of Chlorella protothecoides chloroplasts for illumina genome sequencing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Angelova, Angelina; Park, Sang-Hycuk; Kyndt, John

    2013-09-01

    With the increasing world demand for biofuel, a number of oleaginous algal species are being considered as renewable sources of oil. Chlorella protothecoides Krüger synthesizes triacylglycerols (TAGs) as storage compounds that can be converted into renewable fuel utilizing an anabolic pathway that is poorly understood. The paucity of algal chloroplast genome sequences has been an important constraint to chloroplast transformation and for studying gene expression in TAGs pathways. In this study, the intact chloroplasts were released from algal cells using sonication followed by sucrose gradient centrifugation, resulting in a 2.36-fold enrichment of chloroplasts from C. protothecoides, based on qPCR analysis.more » The C. protothecoides chloroplast genome (cpDNA) was determined using the Illumina HiSeq 2000 sequencing platform and found to be 84,576 Kb in size (8.57 Kb) in size, with a GC content of 30.8 %. This is the first report of an optimized protocol that uses a sonication step, followed by sucrose gradient centrifugation, to release and enrich intact chloroplasts from a microalga (C. prototheocoides) of sufficient quality to permit chloroplast genome sequencing with high coverage, while minimizing nuclear genome contamination. The approach is expected to guide chloroplast isolation from other oleaginous algal species for a variety of uses that benefit from enrichment of chloroplasts, ranging from biochemical analysis to genomics studies.« less

  2. Axisymmetric drop shape analysis for estimating the surface tension of cell aggregates by centrifugation.

    PubMed

    Kalantarian, Ali; Ninomiya, Hiromasa; Saad, Sameh M I; David, Robert; Winklbauer, Rudolf; Neumann, A Wilhelm

    2009-02-18

    Biological tissues behave in certain respects like liquids. Consequently, the surface tension concept can be used to explain aspects of the in vitro and in vivo behavior of multicellular aggregates. Unfortunately, conventional methods of surface tension measurement cannot be readily applied to small cell aggregates. This difficulty can be overcome by an experimentally straightforward method consisting of centrifugation followed by axisymmetric drop shape analysis (ADSA). Since the aggregates typically show roughness, standard ADSA cannot be applied and we introduce a novel numerical method called ADSA-IP (ADSA for imperfect profile) for this purpose. To examine the new methodology, embryonic tissues from the gastrula of the frog, Xenopus laevis, deformed in the centrifuge are used. It is confirmed that surface tension measurements are independent of centrifugal force and aggregate size. Surface tension is measured for ectodermal cells in four sample batches, and varies between 1.1 and 7.7 mJ/m2. Surface tension is also measured for aggregates of cells expressing cytoplasmically truncated EP/C-cadherin, and is approximately half as large. In parallel, such aggregates show a reduction in convergent extension-driven elongation after activin treatment, reflecting diminished intercellular cohesion.

  3. Centrifugal acceleration of ions in the polar magnetosphere

    NASA Technical Reports Server (NTRS)

    Swinney, Kenneth R.; Horwitz, James L.; Delcourt, D.

    1987-01-01

    The transport of ionospheric ions originating near the dayside cusp into the magnetotail is parametrically studied using a 3-D model of ion trajectories. It is shown that the centrifugal term in the guiding center parallel force equation dominates the parallel motion after about 4 Re geocentric distance. The dependence of the equatorial crossing distance on initial latitude, energy and convection electric field is presented for ions originating on the dayside ionosphere in the noon-midnight plane. It is also found that up to altitudes of about 5 Re, the motion is similar to that of a bead on a rotating rod, for which a simple analytical solution exists.

  4. Gravity Responsive NADH Oxidase of the Plasma Membrane

    NASA Technical Reports Server (NTRS)

    Morre, D. James (Inventor)

    2002-01-01

    A method and apparatus for sensing gravity using an NADH oxidase of the plasma membrane which has been found to respond to unit gravity and low centrifugal g forces. The oxidation rate of NADH supplied to the NADH oxidase is measured and translated to represent the relative gravitational force exerted on the protein. The NADH oxidase of the plasma membrane may be obtained from plant or animal sources or may be produced recombinantly.

  5. Ceramic blade attachment system

    DOEpatents

    Boyd, G.L.

    1995-04-11

    A retainer ring is arranged to mount turbine blades to a turbine disk so that aerodynamic forces produced by a gas turbine engine are transferred from the turbine blades to the turbine disk to cause the turbine blades and turbine disk to rotate, but so that centrifugal forces of the turbine blades resulting from the rotation of the turbine blades and turbine disk are not transferred from the turbine blades to the turbine disk. 6 figures.

  6. Vibrating fuel grapple

    DOEpatents

    Chertock, deceased, Alan J.; Fox, Jack N.; Weissinger, Robert B.

    1982-01-01

    A reactor refueling method utilizing a vibrating fuel grapple for removing spent fuel assemblies from a reactor core which incorporates a pneumatic vibrator in the grapple head, enabling additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.

  7. Body height and arterial pressure in seated and supine young males during +2 G centrifugation.

    PubMed

    Arvedsen, Sine K; Eiken, Ola; Kölegård, Roger; Petersen, Lonnie G; Norsk, Peter; Damgaard, Morten

    2015-11-01

    It is known that arterial pressure correlates positively with body height in males, and it has been suggested that this is due to the increasing vertical hydrostatic gradient from the heart to the carotid baroreceptors. Therefore, we tested the hypothesis that a higher gravito-inertial stress induced by the use of a human centrifuge would increase mean arterial pressure (MAP) more in tall than in short males in the seated position. In short (162-171 cm; n = 8) and tall (194-203 cm; n = 10) healthy males (18-41 yr), brachial arterial pressure, heart rate (HR), and cardiac output were measured during +2G centrifugation, while they were seated upright with the legs kept horizontal (+2Gz). In a separate experiment, the same measurements were done with the subjects supine (+2Gx). During +2Gz MAP increased in the short (22 ± 2 mmHg, P < 0.0001) and tall (23 ± 2 mmHg, P < 0.0001) males, with no significant difference between the groups. HR increased more (P < 0.05) in the tall than in the short group (14 ± 2 vs. 7 ± 2 bpm). Stroke volume (SV) decreased in the short group (26 ± 4 ml, P = 0.001) and more so in the tall group (39 ± 5 ml, P < 0.0001; short vs. tall, P = 0.047). During +2Gx, systolic arterial pressure increased (P < 0.001) and SV (P = 0.012) decreased in the tall group only. In conclusion, during +2Gz, MAP increased in both short and tall males, with no difference between the groups. However, in the tall group, HR increased more during +2Gz, which could be caused by a larger hydrostatic pressure gradient from heart to head, leading to greater inhibition of the carotid baroreceptors. Copyright © 2015 the American Physiological Society.

  8. Design analysis and performance assessment of hybrid magnetic bearings for a rotary centrifugal blood pump.

    PubMed

    Ren, Zhaohui; Jahanmir, Said; Heshmat, Hooshang; Hunsberger, Andrew Z; Walton, James F

    2009-01-01

    A hybrid magnetic bearing system was designed for a rotary centrifugal blood pump being developed to provide long-term circulatory support for heart failure patients. This design consists of two compact bearings to suspend the rotor in five degrees-of-freedom with single axis active control. Permanent magnets are used to provide passive radial support and electromagnets to maintain axial stability of the rotor. Characteristics of the passive radial and active thrust magnetic bearing system were evaluated by the electromagnetic finite element analysis. A proportional-integral-derivative controller with force balance algorithm was implemented for closed loop control of the magnetic thrust bearing. The control position is continuously adjusted based on the electrical energy in the bearing coils, and thus passive magnetic forces carry static thrust loads to minimize the bearing current. Performance of the magnetic bearing system with associated control algorithm was evaluated at different operating conditions. The bearing current was significantly reduced with the force balance control method and the power consumption was below 0.5 W under various thrust loads. The bearing parameters predicted by the analysis were validated by the experimental data.

  9. Surface-Plasmon-Mediated Gradient Force Enhancement and Mechanical State Transitions of Graphene Sheets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Peng; Shen, Nian-Hai; Koschny, Thomas

    Graphene, a two-dimensional material possessing extraordinary properties in electronics as well as mechanics, provides a great platform for various optoelectronic and opto-mechanical devices. Here in this article, we theoretically study the optical gradient force arising from the coupling of surface plasmon modes on parallel graphene sheets, which can be several orders stronger than that between regular dielectric waveguides. Furthermore, with an energy functional optimization model, possible force-induced deformation of graphene sheets is calculated. We show that the significantly enhanced optical gradient force may lead to mechanical state transitions of graphene sheets, which are accompanied by abrupt changes in reflection andmore » transmission spectra of the system. Our demonstrations illustrate the potential for a broader graphene-related applications such as force sensors and actuators.« less

  10. Surface-Plasmon-Mediated Gradient Force Enhancement and Mechanical State Transitions of Graphene Sheets

    DOE PAGES

    Zhang, Peng; Shen, Nian-Hai; Koschny, Thomas; ...

    2016-12-16

    Graphene, a two-dimensional material possessing extraordinary properties in electronics as well as mechanics, provides a great platform for various optoelectronic and opto-mechanical devices. Here in this article, we theoretically study the optical gradient force arising from the coupling of surface plasmon modes on parallel graphene sheets, which can be several orders stronger than that between regular dielectric waveguides. Furthermore, with an energy functional optimization model, possible force-induced deformation of graphene sheets is calculated. We show that the significantly enhanced optical gradient force may lead to mechanical state transitions of graphene sheets, which are accompanied by abrupt changes in reflection andmore » transmission spectra of the system. Our demonstrations illustrate the potential for a broader graphene-related applications such as force sensors and actuators.« less

  11. Measuring Rock-Fluid Adhesion Directly

    NASA Astrophysics Data System (ADS)

    Tadmor, R.

    2017-12-01

    We show how to measure directly solid-liquid adhesion. We consider the normal adhesion, the work adhesion, and the lateral adhesion. The technique at the center of the method is Centrifugal Adhesion Balance (CAB) which allows coordinated manipulation of normal and lateral forces. For example: 1. It allows to induce an increase in the normal force which pulls on a liquid drop while keeping zero lateral force. This method mimics a drop that is subjected to a gravitational force that is gradually increasing. 2. It allows to increase the lateral force at zero normal force, mimicking zero gravity. From this one can obtain additional solid-liquid interaction parameters. When performing work of adhesion measurements, the values obtained are independent of drop size and are in agreement with theoretical predictions.

  12. Alternative polymer separation technology by centrifugal force in a melted state.

    PubMed

    Dobrovszky, Károly; Ronkay, Ferenc

    2014-11-01

    In order to upgrade polymer waste during recycling, separation should take place at high purity. The present research was aimed to develop a novel, alternative separation opportunity, where the polymer fractions were separated by centrifugal force in melted state. The efficiency of the constructed separation equipment was verified by two immiscible plastics (polyethylene terephthalate, PET; low density polyethylene, LDPE), which have a high difference of density, and of which large quantities can also be found in the municipal solid waste. The results show that the developed equipment is suitable not only for separating dry blended mixtures of PET/LDPE into pure components again, but also for separating prefabricated polymer blends. By this process it becomes possible to recover pure polymer substances from multi-component products during the recycling process. The adequacy of results was verified by differential scanning calorimetry (DSC) measurement as well as optical microscopy and Raman spectroscopy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. On the stability of fast rotating magentodiscs

    NASA Astrophysics Data System (ADS)

    Neupane, B. R.; Delamere, P. A.; Ma, X.

    2016-12-01

    In this study, a steady-state, self-consistent magnetodisc model (i.e., Caudal [1986] model based on in-situ observational temperature and density profile) has been developed to systematically investigate the stability of fast rotationing magnetodiscs, which is fundamentally important to the dynamics of Jupiter's and Saturn's magnetospheres. Comparison between model and observational data (magnetic field component normal to the equatorial plane) suggests that Saturn's magnetodisc equilibrium is dominated by the heavy and cold plasma, where the centrifugal force cannot be ignored. In contrast, the hot tenuous plasma contribution, in which the centrifugal force can be ignored, should be small. In general, the stability of the Saturn's magnetosphere is determined by the competition between the radial decrease of flux tube content and radial increase of flux tube entropy. The profiles of flux tube content and flux tube entropy are expected to vary under different solar wind dynamic pressure conditions, consequently changing the stability of the magnetosphere. We will discuss stability during solar wind compression and expansion.

  14. Compressive yield stress of depletion gels from stationary centrifugation profiles

    NASA Astrophysics Data System (ADS)

    Lattuada, Enrico; Buzzaccaro, Stefano; Piazza, Roberto

    2018-01-01

    We have investigated the stationary sedimentation profiles of colloidal gels obtained by an arrested phase-separation process driven by depletion forces, which have been compressed either by natural gravity or by a centrifugal acceleration ranging between 6g and 2300g. Our measurements show that the gel rheological properties display a drastic change when the gel particle volume fraction exceeds a value φc , which barely depends on the strength of the interparticle attractive forces that consolidate the network. In particular, the gel compressive yield stress \\Pi(φ) , which increases as \\Pi(φ) ∼ φ4.2 for φ ≲ φc , displays a diverging behaviour for φ>φc , with an asymptotic value that is close to the random close packing value for hard spheres. The evidence we obtained suggests that φc basically coincides with the liquid (colloid-rich) branch of the metastable coexistence curve, rather than with the lower (and ϕ-dependent) values expected for an attractive glass line penetrating inside the coexistence region.

  15. Combined centrifugal force/gravity gas/liquid separator system

    NASA Astrophysics Data System (ADS)

    Lema, Luis E.

    1993-04-01

    A gas/liquid separator system has an outer enclosing tank filled with a demisting packing material. The tank has a gas outlet port and a liquid outlet port located at its top and bottom, respectively. At least one cylindrical, centrifugal force gas/liquid separator is vertically aligned and centrally located within the tank and is surrounded by the packing material. The cylindrical separator receives a gas/liquid mixture, separates the mixture into respective substantially gas and substantially liquid components, and allows the substantially gas components to exit its gas escape port. It also allows the substantially liquid components to exit its liquid escape port. The packing material in the tank further separates the substantially gas and liquid components as they rise and fall, respectively, through the packing material. An inflow line introduces the mixture into the cylindrical separator. The inflow line is upwardly inclined in a direction of flow of the mixture at a point where the inflow line communicates with the cylindrical separator.

  16. Rotary-Atomizer Electric Power Generator

    NASA Astrophysics Data System (ADS)

    Nguyen, Trieu; Tran, Tuan; de Boer, Hans; van den Berg, Albert; Eijkel, Jan C. T.

    2015-03-01

    We report experimental and theoretical results on a ballistic energy-conversion method based on a rotary atomizer working with a droplet acceleration-deceleration cycle. In a rotary atomizer, liquid is fed onto the center of a rotating flat surface, where it spreads out under the action of the centrifugal force and creates "atomized" droplets at its edge. The advantage of using a rotary atomizer is that the centrifugal force exerted on the fluid on a smooth, large surface is not only a robust form of acceleration, as it avoids clogging, but also easily allows high throughput, and produces high electrical power. We successfully demonstrate an output power of 4.9 mW and a high voltage up to 3120 V. At present, the efficiency of the system is still low (0.14%). However, the conversion mechanism of the system is fully interpreted in this paper, permitting a conceptual understanding of system operation and providing a roadmap for system optimization. This observation will open up a road for building power-generation systems in the near future.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buddemeier, R.W.; Oberdorfer, J.A.

    A wide variety of forces can produce head gradients that drive the flow and advective mixing of internal coral reef pore waters. Oscillatory gradients that produce mixing result from wave and tide action. Sustained gradients result from wave and tide-induced setup and ponding, from currents impinging on the reef structure, from groundwater heads, and from density differenced (temperature or salinity gradients). These gradients and the permeabilities and porosities of reef sediments are such that most macropore environments are dominated by advection rather than diffusion. The various driving forces must be analyzed to determine the individual and combined magnitudes of theirmore » effects on a specific reef pore-water system. Pore-water movement controls sediment diagenesis, the exchange of nutrients between sediments and benthos, and coastal/island groundwater resources. Because of the complexity of forcing functions, their interactions with specific local reef environments, experimental studies require careful incorporation of these considerations into their design and interpretation. 8 refs., 3 figs., 1 tab.« less

  18. Unsteady behavior of leading-edge vortex and diffuser stall in a centrifugal compressor with vaned diffuser

    NASA Astrophysics Data System (ADS)

    Fujisawa, Nobumichi; Hara, Shotaro; Ohta, Yutaka

    2016-02-01

    The characteristics of a rotating stall of an impeller and diffuser and the evolution of a vortex generated at the diffuser leading-edge (i.e., the leading-edge vortex (LEV)) in a centrifugal compressor were investigated by experiments and numerical analysis. The results of the experiments revealed that both the impeller and diffuser rotating stalls occurred at 55 and 25 Hz during off-design flow operation. For both, stall cells existed only on the shroud side of the flow passages, which is very close to the source location of the LEV. According to the CFD results, the LEV is made up of multiple vortices. The LEV is a combination of a separated vortex near the leading- edge and a longitudinal vortex generated by the extended tip-leakage flow from the impeller. Therefore, the LEV is generated by the accumulation of vorticity caused by the velocity gradient of the impeller discharge flow. In partial-flow operation, the spanwise extent and the position of the LEV origin are temporarily transmuted. The LEV develops with a drop in the velocity in the diffuser passage and forms a significant blockage within the diffuser passage. Therefore, the LEV may be regarded as being one of the causes of a diffuser stall in a centrifugal compressor.

  19. Direct numerical simulation of Taylor-Couette flow subjected to a radial temperature gradient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teng, Hao; Liu, Nansheng, E-mail: lns@ustc.edu.cn; Lu, Xiyun

    Direct numerical simulations have been performed to study the Taylor-Couette (TC) flow between two rotating, coaxial cylinders in the presence of a radial temperature gradient. Specifically, the influence of the buoyant force and the outer cylinder rotation on the turbulent TC flow system with the radius ratio η = 0.912 was examined. For the co-rotating TC flows with Re{sub i} (inner cylinder) =1000 and Re{sub o} (outer cylinder) =100, a transition pathway to highly turbulent flows is realized by increasing σ, a parameter signifying the ratio of buoyant to inertial force. This nonlinear flow transition involves four intriguing states thatmore » emerge in sequence as chaotic wavy vortex flow for σ = 0, wavy interpenetrating spiral flows for σ = 0.02 and 0.05, intermittent turbulent spirals for σ = 0.1 and 0.2, and turbulent spirals for σ = 0.4. Overall, the fluid motion changes from a centrifugally driven flow regime characterized by large-scale wavy Taylor vortices (TVs) to a buoyancy-dominated flow regime characterized by small-scale turbulent vortices. Commensurate changes in turbulence statistics and heat transfer are seen as a result of the weakening of large-scale TV circulations and enhancement of turbulent motions. Additionally, the influence of variation of the outer cylinder rotation, −500 < Re{sub o} < 500 in presence of buoyancy (σ = 0.1) with Re{sub i} = 1000, has been considered. Specifically, it is demonstrated that this variation strongly influences the azimuthal and axial mean flows with a weaker influence on the fluctuating fluid motions. Of special interest, here are the turbulent dynamics near the outer wall where a marked decrease of turbulence intensity and a sign inversion of the Reynolds stress R{sub rz} are observed for the strongly counter-rotating regimes (Re{sub o} = − 300 and −500). To this end, it has been shown that the underlying flow physics for this drastic modification are associated with the modification of the correlation between the radial and axial fluctuating motions. In turn, the intriguing effects of this modification on the mean axial flow, turbulent statistics, force balance, and dynamic processes such as turbulence production and dissipation are discussed.« less

  20. Coherent Multimodal Sensory Information Allows Switching between Gravitoinertial Contexts

    PubMed Central

    Barbiero, Marie; Rousseau, Célia; Papaxanthis, Charalambos; White, Olivier

    2017-01-01

    Whether the central nervous system is capable to switch between contexts critically depends on experimental details. Motor control studies regularly adopt robotic devices to perturb the dynamics of a certain task. Other approaches investigate motor control by altering the gravitoinertial context itself as in parabolic flights and human centrifuges. In contrast to conventional robotic experiments, where only the hand is perturbed, these gravitoinertial or immersive settings coherently plunge participants into new environments. However, radically different they are, perfect adaptation of motor responses are commonly reported. In object manipulation tasks, this translates into a good matching of the grasping force or grip force to the destabilizing load force. One possible bias in these protocols is the predictability of the forthcoming dynamics. Here we test whether the successful switching and adaptation processes observed in immersive environments are a consequence of the fact that participants can predict the perturbation schedule. We used a short arm human centrifuge to decouple the effects of space and time on the dynamics of an object manipulation task by adding an unnatural explicit position-dependent force. We created different dynamical contexts by asking 20 participants to move the object at three different paces. These contextual sessions were interleaved such that we could simulate concurrent learning. We assessed adaptation by measuring how grip force was adjusted to this unnatural load force. We found that the motor system can switch between new unusual dynamical contexts, as reported by surprisingly well-adjusted grip forces, and that this capacity is not a mere consequence of the ability to predict the time course of the upcoming dynamics. We posit that a coherent flow of multimodal sensory information born in a homogeneous milieu allows switching between dynamical contexts. PMID:28553233

  1. Rabbit polymorphonuclear leukocytes do not secrete endogenous pyrogens or interleukin 1 when stimulated by endotoxin, polyinosine:polycytosine, or muramyl dipeptide.

    PubMed

    Windle, B E; Murphy, P A; Cooperman, S

    1983-03-01

    Rabbit polymorphonuclear leukocytes were purified from rabbit blood by centrifugation on colloidal silica gradients followed by sedimentation in 4% Ficoll. The purified neutrophils had normal random motility, responded to chemotactic stimuli, phagocytosed zymosan particles, made superoxide, and phagocytosed and killed bacteria. However, they did not secret endogenous pyrogens either spontaneously or in response to stimulation with endotoxin, polyinosine:polycytosine, or muramyl dipeptide. Macrophages isolated on the same gradients secreted some pyrogen spontaneously and secreted considerably more in response to the same three stimuli. This evidence reinforces the idea that macrophages are the only source of endogenous pyrogens, and that pyrogens secreted by cell populations that are rich in neutrophils are to be attributed to the monocytes or macrophages that the cell populations contain.

  2. Generation of Human Induced Pluripotent Stem Cells from Peripheral Blood Mononuclear Cells Using Sendai Virus.

    PubMed

    Soares, Filipa A C; Pedersen, Roger A; Vallier, Ludovic

    2016-01-01

    This protocol describes the efficient isolation of peripheral blood mononuclear cells from circulating blood via density gradient centrifugation and subsequent generation of integration-free human induced pluripotent stem cells. Peripheral blood mononuclear cells are cultured for 9 days to allow expansion of the erythroblast population. The erythroblasts are then used to derive human induced pluripotent stem cells using Sendai viral vectors, each expressing one of the four reprogramming factors Oct4, Sox2, Klf4, and c-Myc.

  3. [A preparative method for isolating the synaptonemal complexes from mammalian spermatocytes].

    PubMed

    Dadashev, S Ia; Bogdanov, Iu F; Gorach, G G; Kolomiets, O L; Karpova, O I

    1993-01-01

    A method of isolation of synaptonemal complexes (SC) from mouse, rat and Syrian hamster spermatocytes is described. A fraction of pachytene spermatocyte nuclei was obtained by centrifugation of the testis homogenate in stepwise sucrose gradient and then lysed. The resulting chromatine was hydrolysed with DNAse II, and a fraction of isolated SCs was obtained by ultracentrifugation of the hydrolysate. The method can be applied for obtaining the SC fraction from spermatocytes sufficient for cytological, biochemical and molecular biology studies.

  4. Motion of charged particles in planetary magnetospheres with nonelectromagnetic forces

    NASA Technical Reports Server (NTRS)

    Huang, T. S.; Hill, T. W.; Wolf, R. A.

    1988-01-01

    Expressions are derived for the mirror point, the bounce period, the second adiabatic invariant, and the bounce-averaged azimuthal drift velocity as functions of equatorial pitch angle for a charged particle in a dipole magnetic field in the presence of centrifugal, gravitational, and Coriolis forces. These expressions are evaluated numerically, and the results are displayed graphically. The average azimuthal drift speed for a flux tube containing a thermal equilibrium plasma distribution is also evaluated.

  5. Vibrating fuel grapple. [LMFBR

    DOEpatents

    Chertock, A.J.; Fox, J.N.; Weissinger, R.B.

    A reactor refueling method is described which utilizes a vibrating fuel grapple for removing spent fuel assemblies from a reactor core. It incorporates a pneumatic vibrator in the grapple head which allows additional withdrawal capability without exceeding the allowable axial force limit. The only moving part in the vibrator is a steel ball, pneumatically driven by a gas, such as argon, around a track, with centrifugal force created by the ball being transmitted through the grapple to the assembly handling socket.

  6. Characterization of centrifugally-loaded flame migration for ultra-compact combustors

    NASA Astrophysics Data System (ADS)

    LeBay, Kenneth D.

    The Air Force Research Laboratory (AFRL) has designed a centrifugally-loaded Ultra-Compact Combustor (UCC) showing viable merit for reducing gas turbine combustor length by as much as 66%. The overarching goal of this research was to characterize the migration of centrifugally-loaded flames in a sectional model of the UCC to enable scaling of the design from 15 cm to the 50--75 cm diameter of most engines. Two-line Planar Laser-Induced Fluorescence thermometry (PLIF) of OH, time-resolved Particle Image Velocimetry (PIV), and high-speed video data were collected. Using a sectional UCC model, the flame migration angle was determined to be a function of the UCC/core velocity ratio (VR) while both the VR and the centrifugal or "g-load" affected the migration quantity. Higher g-loads and lower VRs yielding higher migration but lower VRs had lower core flow temperatures due to higher core air mass flow. A comparison of the straight and curved UCC sections showed the centrifugal load increased the flame migration but increased unsteadiness. The flame migration into the core was estimated using pressure and temperature measurements upstream, and PIV measurements downstream of the core flow interface with constant density and velocity profile assumptions. The flame migration quantity was used to estimate the core flow temperature which was in relatively good agreement with the measured PLIF values. The migration quantity scaled relatively linearly with the UCC tangential velocity, which corresponds to the g-load value, with the slope determined by the VR. A simple analytical model resulted for the dependence of the migration quantity on the tangential velocity and VR. The quantitative relationships determined in this research provided a detailed description of the migration of centrifugally-loaded flames in a sectional UCC.

  7. Semicircular canal contribution to the perception of roll tilt during gondola centrifugation.

    PubMed

    Tribukait, Arne; Eiken, Ola

    2005-10-01

    Spatial disorientation is an important problem in aviation. The mechanisms behind the sensation of roll tilt during coordinated turns are not well known. The present study aimed at elucidating what kind of semicircular canal information might cause tilts of the subjective horizontal during gondola centrifugation. The subjective visual horizontal (SVH) was measured by means of an adjustable visual line in darkness. Subjects (n = 8) underwent four centrifuge runs (2 G, 5 min), sitting in different positions, i.e., heading forwards, backwards, centripetally, and centrifugally. The roll position of the gondola (60 degrees at 2 G) was controlled so that the subject was always upright with respect to the resultant gravitoinertial force vector. Thus, the semicircular-canal stimulus components in yaw, pitch, and roll were varied to some extent independently of each other. For the forward position the SVH was substantially tilted in a direction compensatory with respect to the inclination of the gondola. For the backward position there was also a tendency to a compensatory SVH tilt. In all subjects the magnitude of tilt was larger for the forward position than for the backward. The group means were +20.9 +/- 8.4 degrees and -6.9 +/- 10.5 degrees (positive sign designates a clockwise deviation of the SVH), p < 0.001, n = 8. There were no significant SVH tilts for the centripetal (+6.4 +/- 10.7 degrees) and centrifugal (+2.1 +/- 4.8 degrees) positions. The effects of deceleration of the centrifuge were very small for all positions. These findings suggest that the substantial SVH tilt after acceleration heading forwards is not directly related to any single component of semicircular canal stimulation but depends on the ability of the brain to expediently process complex stimulus patterns.

  8. VERIFICATION OF HIGH-RATE SEPARATION DEVICES UNDER THE WET-WEATHER FLOW TECHNOLOGIES PILOT - ETV PROGRAM

    EPA Science Inventory

    This paper presents performance verification data on two types of high-rate separation devices utilized for solids removal: Vortex separation devices (a class of physical treatment technologies that use cylindrical chambers to create centrifugal forces that separate settleable so...

  9. The Public Telecommunications Network: A Concept in Transition.

    ERIC Educational Resources Information Center

    Noam, Eli M.

    1987-01-01

    Argues that the traditional centralized model of the public telecommunication networks is being undermined by a host of centrifugal forces, and that a new and open network concept is emerging that breaks down the dichotomy between the telecommunications sector and the rest of the economy. (JD)

  10. AN IMPROVED AIR-DRIVEN TYPE OF ULTRACENTRIFUGE FOR MOLECULAR SEDIMENTATION.

    PubMed

    Bauer, J H; Pickels, E G

    1937-03-31

    1. A description is given of the construction details and operation characteristics of an improved type of air-driven ultracentrifuge operating in vacuum and suitable for the determination of sedimentation constants of protein molecules. 2. The rotor of the centrifuge is made of a forged aluminum alloy; it is oval in shape, measures 185 mm. at its greatest diameter, and weighs 3,430 gm. It carries a transparent cell located at a distance of 65 mm. from the axis of rotation and designed to accommodate a fluid column 15 mm. high. 3. The rotor has been run repeatedly over long periods at a speed of 60,000 R.P.M., which corresponds to a centrifugal force of 260,000 times gravity in the center of the cell. At this speed no deformation of the rotor nor leakage of the cell has been observed. 4. The sharp definition of sedimentation photographs taken at high speed serves to indicate the absence of detectable vibrations in the centrifuge. 5. When a vacuum of less than 1 micron of mercury is maintained in the centrifuge chamber, the rise in the rotor temperature amounts to only 1 or 2 degrees C. after several hours' run at high speed. 6. There has been no evidence of convection currents interfering with normal sedimentation of protein molecules in the centrifugal field. 7. A driving air pressure of about 18 pounds per square inch is sufficient to maintain the centrifuge at a steady speed of 60,000 R.P.M. With a driving pressure of 80 pounds per square inch, it can be accelerated to this speed in less than 20 minutes, and also brought to rest in about the same length of time by the application of the braking system. 8. The adaptation of Svedberg's optical systems to this centrifuge for photographically recording the movement of sedimentation boundaries is described.

  11. AN IMPROVED AIR-DRIVEN TYPE OF ULTRACENTRIFUGE FOR MOLECULAR SEDIMENTATION

    PubMed Central

    Bauer, Johannes H.; Pickels, Edward G.

    1937-01-01

    1. A description is given of the construction details and operation characteristics of an improved type of air-driven ultracentrifuge operating in vacuum and suitable for the determination of sedimentation constants of protein molecules. 2. The rotor of the centrifuge is made of a forged aluminum alloy; it is oval in shape, measures 185 mm. at its greatest diameter, and weighs 3,430 gm. It carries a transparent cell located at a distance of 65 mm. from the axis of rotation and designed to accommodate a fluid column 15 mm. high. 3. The rotor has been run repeatedly over long periods at a speed of 60,000 R.P.M., which corresponds to a centrifugal force of 260,000 times gravity in the center of the cell. At this speed no deformation of the rotor nor leakage of the cell has been observed. 4. The sharp definition of sedimentation photographs taken at high speed serves to indicate the absence of detectable vibrations in the centrifuge. 5. When a vacuum of less than 1 micron of mercury is maintained in the centrifuge chamber, the rise in the rotor temperature amounts to only 1 or 2°C. after several hours' run at high speed. 6. There has been no evidence of convection currents interfering with normal sedimentation of protein molecules in the centrifugal field. 7. A driving air pressure of about 18 pounds per square inch is sufficient to maintain the centrifuge at a steady speed of 60,000 R.P.M. With a driving pressure of 80 pounds per square inch, it can be accelerated to this speed in less than 20 minutes, and also brought to rest in about the same length of time by the application of the braking system. 8. The adaptation of Svedberg's optical systems to this centrifuge for photographically recording the movement of sedimentation boundaries is described. PMID:19870619

  12. Design and Analysis of a Novel Centrifugal Braking Device for a Mechanical Antilock Braking System.

    PubMed

    Yang, Cheng-Ping; Yang, Ming-Shien; Liu, Tyng

    2015-06-01

    A new concept for a mechanical antilock braking system (ABS) with a centrifugal braking device (CBD), termed a centrifugal ABS (C-ABS), is presented and developed in this paper. This new CBD functions as a brake in which the output braking torque adjusts itself depending on the speed of the output rotation. First, the structure and mechanical models of the entire braking system are introduced and established. Second, a numerical computer program for simulating the operation of the system is developed. The characteristics of the system can be easily identified and can be designed with better performance by using this program to studying the effects of different design parameters. Finally, the difference in the braking performance between the C-ABS and the braking system with or without a traditional ABS is discussed. The simulation results indicate that the C-ABS can prevent the wheel from locking even if excessive operating force is provided while still maintaining acceptable braking performance.

  13. A compact disk-like centrifugal microfluidic system for high-throughput nanoliter-scale protein crystallization screening.

    PubMed

    Li, Gang; Chen, Qiang; Li, Junjun; Hu, Xiaojian; Zhao, Jianlong

    2010-06-01

    A centrifuge-based microfluidic system has been developed that enables automated high-throughput and low-volume protein crystallizations. In this system, protein solution was automatically and accurately metered and dispensed into nanoliter-sized multiple reaction chambers, and it was mixed with various types of precipitants using a combination of capillary effect and centrifugal force. It has the advantages of simple fabrication, easy operation, and extremely low waste. To demonstrate the feasibility of this system, we constructed a chip containing 24 units and used it to perform lysozyme and cyan fluorescent protein (CyPet) crystallization trials. The results demonstrate that high-quality crystals can be grown and harvested from such a nanoliter-volume microfluidic system. Compared to other microfluidic technologies for protein crystallization, this microfluidic system allows zero waste, simple structure and convenient operation, which suggests that our microfluidic disk can be applied not only to protein crystallization, but also to the miniaturization of various biochemical reactions requiring precise nanoscale control.

  14. Effect of weightlessness and centrifugation on red cell survival in rats subjected to space flight

    NASA Technical Reports Server (NTRS)

    Leon, H. A.; Serova, L. V.; Landaw, S. A.

    1980-01-01

    Rats were flown aboard the Soviet biosatellite Cosmos 936 for 18.5 d during August, 1977. Five rats were subjected to near-weightless space flight, as with Cosmos 782, and five rats were subjected to a 1-G force via an on-board centrifuge. These rats and three control groups were injected with 2-(C-14) glycine 19 d preflight. The flight rats were recovered from orbit after 18.5 d of space flight. Erythrocyte hemolysis and lifespan were evaluated in the five groups of rats by quantitation of radioactive carbon monoxide exhaled in the breath which arises from the breakdown of the previously labeled hemoglobin. The results support the previous findings wherein hemolysis was found to increase as a result of weightless space flight. A comparison to the centrifuged animals indicates that artificial gravity attenuates the effect of weightlessness on hemolysis and appears to normalize the hemolytic rate in the early postflight period.

  15. Orientation of Magnetized MnBi in a Strong Static Magnetic Field

    NASA Astrophysics Data System (ADS)

    Zheng, Tianxiang; Zhong, Yunbo; Dong, Licheng; Zhou, Bangfei; Ren, Zhongming; Debray, Francois; Beaugnon, Eric

    2018-06-01

    Solidification of Bi-4.5 wt pct Mn alloy was investigated in the presence and absence of a strong static magnetic field (SSMF). A cooling rate ( R) of 60 K/min caused MnBi to orient with the SSMF, owing to the force moment and attractive force. The attractive force and magnetic gradient force induced formation of multilayered MnBi when R was 5 K/min. The magnetic gradient force was damped when R was 60 K/min. Low cooling rates favored the aggregation process.

  16. Manual centrifuge system: Bearing-based hand spinner made with 3-D printer.

    PubMed

    Sun-Young Yoo; Seung Jae Lee; Jong-Mo Seo

    2017-07-01

    Compact disk (CD) Microfluidic platforms are being studied for medical applications such as blood tests. However, its size is bulky and electricity is needed to realize centrifuge force. In this paper, bearing-based hand spinner is designed using three-dimensional printer. This spinner does not need electricity and keeps rotating direction unlike paperfuge while it is spinning. The properties of spinner vary depending on bearing type which is positioned at the center. The type of weighting area also affects change in RPM over time. When a separation experiment is implemented, separating mixture into red ink and oil and whole blood into red blood cell and plasma are achieved properly with ceramic ball bearing.

  17. Knee-ligament loading properties as influenced by gravity. I - Junction with bone of 3-G rodents

    NASA Technical Reports Server (NTRS)

    Wunder, C. C.; Matthes, R. D.; Tipton, C. M.

    1982-01-01

    The effect of 3-G conditions on the bone-to-ligament junctions of the knee is studied in rats. Results following chronic 3-G centrifugation of rats show that their bone-to-ligament junctions exhibited a force-sustaining capacity (F) which was 95 + or - 12% of the value for the control group. However, F was actually 29 + or - 5% greater for centrifuged rats than for control rats of comparable size, as the experimental animals grew to smaller body mass. It is concluded that gravity determines part of the magnitude of F, and therefore this value will probably be weaker after development in a weightless environment.

  18. Techniques For Focusing In Zone Electrophoresis

    NASA Technical Reports Server (NTRS)

    Sharnez, Rizwan; Twitty, Garland E.; Sammons, David W.

    1994-01-01

    In two techniques for focusing in zone electrophoresis, force of applied electrical field in each charged particle balanced by restoring force of electro-osmosis. Two techniques: velocity-gradient focusing (VGF), suitable for rectangular electrophoresis chambers; and field-gradient focusing (FGF), suitable for step-shaped electrophoresis chambers.

  19. Fractionation of oats into products enriched with protein, beta-glucan, starch, or other carbohydrates

    USDA-ARS?s Scientific Manuscript database

    A modified wet method was developed to fractionate ground oat groats into 4 fractions enriched with beta-glucan (BG), protein, starch, and other carbohydrates (CHO), respectively. Effects of defatting oats and centrifuge force for separation were also investigated. Results show that, depending on ...

  20. Educational Project on Indonesia. Fulbright Hayes Summer Seminar.

    ERIC Educational Resources Information Center

    Hribar, Georgeanne C.

    These lesson plans were developed by a participant in the Fulbright Summer Seminar on Indonesia. The materials provide information for teaching about economic and social factors affecting development of the region. There are four lessons in the packet. The lessons are: (1) "Centripetal and Centrifugal Forces" (geographical, historical,…

Top