Science.gov

Sample records for centrifugal partition chromatography

  1. Deep eutectic solvents in countercurrent and centrifugal partition chromatography.

    PubMed

    Roehrer, Simon; Bezold, Franziska; García, Eva Marra; Minceva, Mirjana

    2016-02-19

    Deep eutectic solvents (DESs) were evaluated as solvents in centrifugal partition chromatography, a liquid-liquid chromatography separation technology. To this end, the partition coefficients of ten natural compounds of different hydrophobicity were determined in non-aqueous biphasic systems containing DES. The influence of the composition of DESs and the presence of water in the biphasic system on the partition coefficient were also examined. In addition, several process relevant physical properties of the biphasic system, such as the density and viscosity of the phases, were measured. A mixture of three to four hydrophobic compounds was successfully separated in a centrifugal partition extractor using a heptane/ethanol/DES biphasic system.

  2. Methodology for optimally sized centrifugal partition chromatography columns.

    PubMed

    Chollet, Sébastien; Marchal, Luc; Jérémy Meucci; Renault, Jean-Hugues; Legrand, Jack; Foucault, Alain

    2015-04-03

    Centrifugal Partition Chromatography (CPC) is a separation process based on the partitioning of solutes between two partially miscible liquid phases. There is no solid support for the stationary phase. The centrifugal acceleration is responsible for both stationary phase retention and mobile phase dispersion. CPC is thus a process based on liquid-liquid mass transfer. The separation efficiency is mainly influenced by the hydrodynamics of the phases in each cell of the column. Thanks to a visualization system, called "Visual CPC", it was observed that the mobile phase can flow through the stationary phase as a sheet, or a spray. Hydrodynamics, which directly governs the instrument efficiency, is directly affected during scale changes, and non-linear phenomena prevent the successful achievement of mastered geometrical scale changes. In this work, a methodology for CPC column sizing is proposed, based on the characterization of the efficiency of advanced cell shapes, taking into account the hydrodynamics. Knowledge about relationship between stationary phase volume, cell efficiency and separation resolution in CPC allowed calculating the optimum cell number for laboratory and industrial scale CPC application. The methodology is highlighted with results on five different geometries from 25 to 5000 mL, for two applications: the separation of alkylbenzene by partitioning with heptane/methanol/water biphasic system; and the separation of peptides by partitioning with n-butanol/acetic acid/water (4/1/5) biphasic system. With this approach, it is possible to predict the optimal CPC column length leading to highest productivity.

  3. Fast centrifugal partition chromatography as a preparative-scale separation technique for citrus flavones

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Fast centrifugal partition chromatography (FCPC) is a preparative-scale separations methodology based on the principles of counter current chromatography. Separations by FCPC are typically achieved with higher recoveries and with lower solvent use compared to conventional column chromatography. HSCP...

  4. Carnosol purification. Scaling-up centrifugal partition chromatography separations.

    PubMed

    Bouju, Elodie; Berthod, Alain; Faure, Karine

    2016-09-30

    This paper illustrates the application of a recently proposed protocol allowing the scale-up prediction on hydrostatic countercurrent chromatography columns (centrifugal partition chromatographs or CPC). A commercial extract of rosemary (Rosmarinus officinalis L.) was used as the starting material containing 0.48% of carnosol, an active pharmaceutical ingredient with great potential. After a rapid method development on a small-scale 35-mL CPC instrument that allowed for the determination of the solvent system and maximum sample concentration and volume, the purification was transferred on two larger instruments using the "free space between peaks" method. The method takes into account the technical limitations of the larger instruments, such as pressure and/or maximum centrifugal field, and allows, by simply running an analytical-sized injection on the large scale rotor, to give an accurate prediction of the maximum sample load and best throughput. The 0.27g of rosemary extract maximum load on a 35-mL CPC was transferred as a 1.9g load on a 254-mL medium size CPC and 9g load on a 812-mL CPC. The maximum process efficiency of 3.1mg of carnosol per hour obtained on the small 35-mL column was transferred on the 254-mL CPC giving 8.3mg/h and, on the larger 812-mL column 49.4mg of carnosol could be obtained per hour. If the scaling-up in CPC instruments is not directly homothetic, it can be highly predictable through a few simple experiments.

  5. Solanidine isolation from Solanum tuberosum by centrifugal partition chromatography.

    PubMed

    Attoumbré, Jacques; Giordanengo, Philippe; Baltora-Rosset, Sylvie

    2013-07-01

    The aim of this investigation was the preparative isolation of solanidine (aglycone of the two main potato glycoalkaloids: α-chaconine and α-solanine) from fresh Solanum tuberosum (cv. Pompadour) material by implementing a new preparation scheme using centrifugal partition chromatography (CPC). A setup for obtaining solanidine by hydrolysis of the glycoalkaloids found in the skin and sprouts of S. tuberosum was first developed. Then its isolation was carried out by the development of CPC conditions: the solvent system used for separation was ethyl acetate/butanol/water in the ratio 42.5:7.5:50 v/v/v, 0.6 g of crude extract were separated with a 8 mL/min flow rate of mobile phase while rotating at 2500 rpm. A run yielded 98 mg of solanidine (86.7% recovery from the crude extract) in a one-step separation. The purity of the isolated solanidine was over 98%. Thus, CPC has proven to be the method of choice to get solanidine of very high purity from S. tuberosum biomass in large quantities.

  6. Preparative isolation and purification of sinomenine from Sinomenium acutum by centrifugal partition chromatography.

    PubMed

    Cheong, Jong Hye; Kim, Chul Young; Kim, Jinwoong

    2007-08-01

    Preparative centrifugal partition chromatography (CPC) was successfully carried out for the separation of sinomenine from the methanolic extract of Sinomenium acutum stems and rhizomes. The optimum two-phase solvent system of CPC was composed of n-hexane/ethyl acetate/methanol/water at a volume ratio of 1:6:2:8 (v/v/v/v) with 0.1% triethylamine (TEA). Preparative CPC yielded 44.3 mg of sinomenine from 400 mg of MeOH extract with a purity of 96.9%.

  7. Alternative separation steps for monoclonal antibody purification: combination of centrifugal partitioning chromatography and precipitation.

    PubMed

    Oelmeier, Stefan A; Ladd-Effio, Christopher; Hubbuch, Jürgen

    2013-12-06

    Protein drugs continue to grow both in medicinal importance as in scale of their production. This furthers the interest in separation technologies that have the potential to replace chromatographic steps in a protein purification process. Two such unit operations that are employed in large scale in the chemical industry are extraction and precipitation. Their usefulness for the purification of proteins has been demonstrated, but the integration of such unit operations in a way that generate an output stream of high protein concentration and low process related impurities was missing. In this work, we employ centrifugal partitioning chromatography ('CPC') in combination with precipitation of the protein of interest to purify a cell culture supernatant of a monoclonal antibody producing cell line. Centrifugal partitioning chromatography was used as means of multi-step extraction using aqueous two-phase systems and was able to remove up to 88.2% of host cell protein ('HCP'). The following PEG driven precipitation and resolubilization of the protein of interest was use to condition the CPC output stream to suit subsequent chromatographic steps, to increase mAb concentration, remove the phase forming polymer, further improve HCP clearance, and integrate a low pH hold step for viral clearance. The entire process reduced HCP content by 99.4% while recovering 93% of the protein of interest. High throughput screening techniques were extensively employed during the development of the process.

  8. 5-O-caffeoylshikimic acid from Solanum somalense leaves: advantage of centrifugal partition chromatography over conventional column chromatography.

    PubMed

    Chideh, Saïda; Pilard, Serge; Attoumbré, Jacques; Saguez, Robert; Hassan-Abdallah, Alshaimaa; Cailleu, Dominique; Wadouachi, Anne; Baltora-Rosset, Sylvie

    2014-09-01

    Solanum somalense leaves, used in Djibouti for their medicinal properties, were extracted by MeOH. Because of the high polyphenol and flavonoid contents of the extract, respectively, determined at 80.80 ± 2.13 mg gallic acid equivalent/g dry weight and 24.4 ± 1.01 mg quercetin equivalent/g dry weight, the isolation and purification of the main polyphenols were carried out by silica gel column chromatography and centrifugal partition chromatography. Column chromatography led to 11 enriched fractions requiring further purification, while centrifugal partition chromatography allowed the easy recovery of the main compound of the extract. In a solvent system composed of CHCl3/MeOH/H2O (9.5:10:5), 21.8 mg of this compound at 97% purity was obtained leading to a yield of 2.63%. Its structure was established as 5-O-caffeoylshikimic acid by mass spectrometry and NMR spectroscopy. This work shows that S. somalense leaves contain very high level of 5-O-caffeoylshikimic acid (0.74% dry weight), making it a potential source of production of this secondary metabolite that is not commonly found in nature but could be partly responsible of the medicinal properties of S. somalense leaves.

  9. Preparative separation of glycoalkaloids α-solanine and α-chaconine by centrifugal partition chromatography.

    PubMed

    Attoumbré, Jacques; Lesur, David; Giordanengo, Philippe; Baltora-Rosset, Sylvie

    2012-11-01

    The main glycoalkaloids of a commercial potato cultivar, α-chaconine and α-solanine, were extracted from sprouts of Solanum tuberosum cv. Pompadour by a mixture of MeOH/H(2)O/CH(3)COOH (400/100/50, v/v/v). In these conditions, 2.8±0.62g of crude extract were obtained from 50g of fresh sprouts and the total glycoalkaloid content was determined by analytical HPLC at 216.5mg/100g. α-Chaconine and α-solanine were separated in a preparative scale using centrifugal partition chromatography (CPC). In a solvent system composed of a mixture of ethyl acetate/butanol/water (15/35/50, v/v/v), α-chaconine (54mg) and α-solanine (15mg) were successfully isolated from the crude extract in one step of purification. The purity of isolated compounds was determined to be higher than 92% by HPLC analysis.

  10. Centrifugal partition chromatography applied to the isolation of oak wood aroma precursors.

    PubMed

    Slaghenaufi, Davide; Marchand-Marion, Stéphanie; Richard, Tristan; Waffo-Teguo, Pierre; Bisson, Jonathan; Monti, Jean-Pierre; Merillon, Jean-Michel; de Revel, Gilles

    2013-12-01

    Flavours extracted from oak wood during barrel ageing contribute to the organoleptic character of wines and spirits. The aim of this work was to identify the glycosidic precursors of the key volatile compounds responsible for oak wood aroma. Oak extract is a very complex matrix and, furthermore, precursors are present in very small quantities. Preparative centrifugal partition chromatography (CPC) is a promising solution for purifying the oak extract. The solvent system was selected on the basis of the partition coefficient of glycosidase enzyme activity (Kca). Thanks to the efficacy of CPC separation, three glucoside gallates were subsequently isolated by HPLC chromatography. Vanillin-(6'-O-galloyl)-O-β-D-glucopyranoside, 3,4,5-trimethoxyphenyl-(6'-O-galloyl)-O-β-D-glucopyranoside, and (6R,9R)-3-oxo-α-ionol-9-O-(6'-O-galloyl)-β-glucopyranoside (macarangioside E) were isolated and identified. This was the first time that vanillin-(6'-O-galloyl)-O-β-D-glucopyranoside was identified and the first time that macarangioside E was isolated from oak wood. Heating macarangioside E resulted in the formation of megastigmatrienone, which has an aroma reminiscent of tobacco.

  11. Industrial case study on alkaloids purification by pH-zone refining centrifugal partition chromatography.

    PubMed

    Kotland, Alexis; Chollet, Sébastien; Diard, Catherine; Autret, Jean-Marie; Meucci, Jeremy; Renault, Jean-Hugues; Marchal, Luc

    2016-11-25

    The industrial potential of pH-zone refining centrifugal partition chromatography has been evaluated by studying the purification of pharmaceutical ingredients at the pilot scale. For the first time, a scale up methodology based on both column capacity and mass transfer efficiency as invariants was developed. The purification of catharanthine and vindoline from an industrial crude extract of aerial parts of Catharanthus roseus, was used as a case of study. Toluene/CH3CN/water (4/1/5, v/v/v) was selected as biphasic solvent system, triethylamine as retainer in the organic stationary phase and sulphuric acid as displacer in the aqueous mobile phase. The separation intensification was performed on a 36mL CPC column equipped with 832 partition twin-cells. The combined effects of four parameters (displacer and retainer concentrations for intensive parameters, flow rate and rotational speed for extensive parameters) were studied by design of experiment in order to maximize both recoveries and productivities. Then, scale change was done on two larger columns (305mL and 1950mL of capacity) equipped with only 231 and 238 partition cells. For this step, it has been shown that the global mass transfer coefficient k0a (the efficiency of a column design) and the stationary phase retention (the capacity of the column) were relevant and useful scale up invariants. A CPC model based on acid-base equilibriums and interfacial mass transfer in continuously stirred tank reactors in series was used to predict fully separations on larger CPC column at the optimized operating conditions and to guide the CPC user in its scale-up strategy. The experimental validation on pilot CPC column, by injecting up to 150g of Catharanthus roseus crude extract on the 1950mL column highlighted the preservation of the separation quality, the non-linear character of the scale up in centrifugal partition chromatography and that a productivity of about 4kg of processed crude extract per day can be reached

  12. Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography.

    PubMed

    Ikehata, Jun-Ichi; Shinomiya, Kazufusa; Kobayashi, Koji; Ohshima, Hisashi; Kitanaka, Susumu; Ito, Yoichiro

    2004-02-06

    The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.

  13. Hyphenating Centrifugal Partition Chromatography with Nuclear Magnetic Resonance through Automated Solid Phase Extraction.

    PubMed

    Bisson, Jonathan; Brunel, Marion; Badoc, Alain; Da Costa, Grégory; Richard, Tristan; Mérillon, Jean-Michel; Waffo-Téguo, Pierre

    2016-10-18

    Centrifugal partition chromatography (CPC) and all countercurrent separation apparatus provide chemists with efficient ways to work with complex matrixes, especially in the domain of natural products. However, despite the great advances provided by these techniques, more efficient ways of analyzing the output flow would bring further enhancement. This study describe a hyphenated approach made by coupling NMR with CPC through a hybrid-indirect coupling made possible by using a solid phase extraction (SPE) apparatus intended for high-pressure liquid chromatography (HPLC)-NMR hyphenation. Some hardware changes were needed to adapt the incompatible flow-rates and a reverse-engineering approach that led to the specific software required to control the apparatus. 1D (1)HNMR and (1)H-(1)H correlation spectroscopy (COSY) spectra were acquired in reasonable time without the need for any solvent-suppression method thanks to the SPE nitrogen drying step. The reduced usage of expensive deuterated solvents from several hundreds of milliliters to the milliliter order is the major improvement of this approach compared to the previously published ones.

  14. Purification of vandaterosides from Vanda teres (Orchidaceae) by stepwise gradient centrifugal partition chromatography.

    PubMed

    Cakova, Veronika; Urbain, Aurélie; Le Quéméner, Céline; Audo, Grégoire; Bonté, Frédéric; Lobstein, Annelise

    2015-09-01

    Vandaterosides are polar glucosyloxybenzyl eucomate derivatives found in Vanda teres (Orchidaceae), which display biological activities that slow the skin ageing process. In order to obtain larger quantities to allow us to go further in the bioassays, the hydroalcoholic extract of aerial parts (leaves and stems) of V. teres were fractionated by centrifugal partition chromatography, combining isocratic, gradient, and dual elution modes. The first fractionation was performed on the extract maintained in the stationary phase as water saturated in butanol, while increasing the polarity of the mobile phase by changing the proportions of ethyl acetate/1-butanol/water, in order to obtain two enriched fractions. Vandateroside I was then purified by isocratic mode with ethyl acetate/ethanol/water (46:14:40), while vandateroside II was obtained by combining isocratic elution with ethyl acetate/isopropanol/water (30:20:50) followed by a multiple dual mode with ethyl acetate/ethanol/water (46:14:40). In this manner, hundreds of milligrams of vandateroside I and II were recovered from 10 g of V. teres extract.

  15. Centrifugal partition chromatography in a biorefinery context: Separation of monosaccharides from hydrolysed sugar beet pulp.

    PubMed

    Ward, David P; Cárdenas-Fernández, Max; Hewitson, Peter; Ignatova, Svetlana; Lye, Gary J

    2015-09-11

    A critical step in the bioprocessing of sustainable biomass feedstocks, such as sugar beet pulp (SBP), is the isolation of the component sugars from the hydrolysed polysaccharides. This facilitates their subsequent conversion into higher value chemicals and pharmaceutical intermediates. Separation methodologies such as centrifugal partition chromatography (CPC) offer an alternative to traditional resin-based chromatographic techniques for multicomponent sugar separations. Highly polar two-phase systems containing ethanol and aqueous ammonium sulphate are examined here for the separation of monosaccharides present in hydrolysed SBP pectin: l-rhamnose, l-arabinose, d-galactose and d-galacturonic acid. Dimethyl sulfoxide (DMSO) was selected as an effective phase system modifier improving monosaccharide separation. The best phase system identified was ethanol:DMSO:aqueous ammonium sulphate (300gL(-1)) (0.8:0.1:1.8, v:v:v) which enabled separation of the SBP monosaccharides by CPC (200mL column) in ascending mode (upper phase as mobile phase) with a mobile phase flow rate of 8mLmin(-1). A mixture containing all four monosaccharides (1.08g total sugars) in the proportions found in hydrolysed SBP was separated into three main fractions; a pure l-rhamnose fraction (>90%), a mixed l-arabinose/d-galactose fraction and a pure d-galacturonic acid fraction (>90%). The separation took less than 2h demonstrating that CPC is a promising technique for the separation of these sugars with potential for application within an integrated, whole crop biorefinery.

  16. Influence of physical properties and operating parameters on hydrodynamics in Centrifugal Partition Chromatography.

    PubMed

    Adelmann, S; Schembecker, G

    2011-08-12

    Besides the selection of a suitable biphasic solvent system the separation efficiency in Centrifugal Partition Chromatography (CPC) is mainly influenced by the hydrodynamics in the chambers. The flow pattern, the stationary phase retention and the interfacial area for mass transfer strongly depend on physical properties of the solvent system and operating parameters. In order to measure these parameters we visualized the hydrodynamics in a FCPC-chamber for five different solvent systems with an optical measurement system and calculated the stationary phase retention, interfacial area and the distribution of mobile phase thickness in the chamber. Although inclined chambers were used we found that the Coriolis force always deflected the mobile phase towards the chamber wall reducing the interfacial area. This effect increased for systems with low density difference. We also have shown that the stability of phase systems (stationary phase retention) and its tendency to disperse increased for smaller values of the ratio of interfacial tension and density difference. But also the viscosity ratio and the flow pattern itself had a significant effect on retention and dispersion of the mobile phase. As a result operating parameters should be chosen carefully with respect to physical properties for a CPC system. In order to reduce the effect of the Coriolis force CPC devices with greater rotor radius are desirable.

  17. Separation of Aeruginosin-865 from Cultivated Soil Cyanobacterium (Nostoc sp.) by Centrifugal Partition Chromatography combined with Gel Permeation Chromatography.

    PubMed

    Cheel, José; Minceva, Mirjana; Urajová, Petra; Aslam, Rabya; Hrouzek, Pavel; Kopecký, Jiří

    2015-10-01

    Aeruginosin-865 was isolated from cultivated soil cyanobacteria using a combination of centrifugal partition chromatography (CPC) and gel permeation chromatography. The solubility of Aer-865 in different solvents was evaluated using the conductor-like screening model for real solvents (COSMO-RS). The CPC separation was performed in descending mode with a biphasic solvent system composed of water-n-BuOH-acetic acid (5:4:1, v/v/v). The upper phase was used as a stationary phase, whereas the lower phase was employed as a mobile phase at a flow rate of 10 mL/min. The revolution speed and temperature of the separation column were 1700 rpm and 25 degrees C, respectively. Preparative CPC separation followed by gel permeation chromatography was performed on 50 mg of crude extract yielding Aer-865 (3.5 mg), with a purity over 95% as determined by HPLC. The chemical identity of the isolated compound was confirmed by comparing its spectroscopic data (UV, HRESI-MS, HRESI-MS/MS) with those of an authentic standard and data available in the literature.

  18. Centrifugal partition chromatography: A preparative tool for isolation and purification of xylindein from Chlorociboria aeruginosa.

    PubMed

    Boonloed, Anukul; Weber, Genevieve L; Ramzy, Kelly M; Dias, Veronica R; Remcho, Vincent T

    2016-12-23

    A centrifugal partition chromatography (CPC) method was developed for the preparative-scale isolation and purification of xylindein from the wood-staining fungi, Chlorociboria aeruginosa. Xylindein, a blue-green pigment naturally secreted from the hyphae and fruiting bodies of the fungus, has great value in the decorative wood industry and textile coloration. Xylindein has great potential for use as a fluorescent labeling agent as well as in organic semiconductor applications. However, a primary limitation of xylindein is its poor solubility in most common HPLC solvents. Consequently, it is arduous to purify using preparative liquid chromatography or solid-phase extraction (SPE). Support-free, liquid-liquid chromatographic methods, including CPC, where solutes are separated based on their different distribution coefficients (KD) between two immiscible solvent systems, are promising alternatives for the purification of the compound on a preparative scale. In this work, a new biphasic solvent system suitable for CPC separation of xylindein was developed. Various groups of solvents were assessed for their suitability as xylindein extractants. A new solvent system suitable for CPC separation of xylindein, composed of heptane/THF/MEK/acetonitrile/acetic acid/water, was developed. This solvent system yielded a KD value for xylindein of 1.54±0.04, as determined by HPLC (n=3). The compositions of the upper phase and lower phase of the solvent system were determined by Heteronuclear Single Quantum Correlation (HSQC) NMR and proton NMR. A CPC system, equipped with a fraction collector, was used for the isolation of xylindein from crude extracts. The xylindein fractions isolated by the CPC were then analyzed using HPLC and presented as a fractogram. Based on the CPC fractogram, the purified xylindein fractions were achieved after 30min CPC separation time, yielding 71% extraction efficiency. The developed CPC method allowed for isolation of this naturally sourced xylindein

  19. Intensified Separation of Steviol Glycosides from a Crude Aqueous Extract of Stevia rebaudiana Leaves Using Centrifugal Partition Chromatography.

    PubMed

    Hubert, Jane; Borie, Nicolas; Chollet, Sébastien; Perret, Joël; Barbet-Massin, Claire; Berger, Monique; Daydé, Jean; Renault, Jean-Hugues

    2015-11-01

    Aqueous extracts of Stevia rebaudiana leaves have been approved since 2008 by the Joint Expert Committee for Food Additives as sugar substitutes in many food and beverages in Western and Far East Asian countries. The compounds responsible for the natural sweetness of Stevia leaves include a diversity of diterpenoid glycosides derived from a steviol skeleton. These steviol glycosides also exhibit a low calorific value as well as promising therapeutic applications, particularly for the treatment of sugar metabolism disturbances. In this work, centrifugal partition chromatography is proposed as an efficient technical alternative to purify steviol glycosides from crude aqueous extracts of Stevia leaves on a multigram scale. Two different commercial instruments, including an ASCPC250® and a FCPE300® made of columns containing 1890 and 231 twin-cells, respectively, were evaluated and compared. All experiments were performed with a polar biphasic solvent system composed of ethyl acetate, n-butanol, and water in a gradient elution mode. When using the 1890 partition cell centrifugal partition chromatography column of 250 mL, 42 mg of stevioside, 68 mg of dulcoside A, and 172 mg of rebaudioside A, three major constituents of the initial extract were obtained from 1 g of the initial mixture at purities of 81%, 83%, and 99%, respectively. The productivity was further improved by intensifying the procedure on the 231 partition cell centrifugal partition chromatography column of 303 mL with the sample mass loading increased up to 5 g, resulting in the recovery of 1.2 g of stevioside, 100 mg of dulcoside A, and 1.1 g of rebaudioside A at purities of 79%, 62%, and 98%, respectively. The structures of the isolated compounds were validated by HPLC-UV, ESI-MS, (1)H, and (13)C NMR analyses. Altogether, the results demonstrate that the column design (i.e., the partition cell number) is an important aspect to be considered for a larger scale centrifugal partition chromatography

  20. A comprehensive classification of solvent systems used for natural product purifications in countercurrent and centrifugal partition chromatography.

    PubMed

    Skalicka-Woźniak, Krystyna; Garrard, Ian

    2015-11-01

    Using both library paper copies and modern electronic copies, every known, published, English-language journal paper that employs either countercurrent or centrifugal partition chromatography solvent systems for natural product purifications has been studied and the solvent systems classified in a comprehensive database. Papers were studied from the earliest found examples containing natural product separations in 1984 until the end of 2014. In total, 2594 solvent systems have been classified, of which 272 are gradient systems. To observe any trends or patterns in the data, the natural product solutes were divided into 21 classes and the solvent systems into 7 different types. The complete database, sorted according to natural product class, is available for download to assist separation scientists in future liquid-liquid chromatography purifications.

  1. Large scale purification of the SERCA inhibitor thapsigargin from Thapsia garganica L. roots using centrifugal partition chromatography.

    PubMed

    Ollivier, Anthony; Grougnet, Raphaël; Cachet, Xavier; Meriane, Djamila; Ardisson, Janick; Boutefnouchet, Sabrina; Deguin, Brigitte

    2013-05-01

    Thapsigargin (Tg) is a selective and irreversible inhibitor of the sarcoplasmic/endoplasmic reticulum calcium ATPase (SERCA)-dependent pump at subnanomolecular concentrations. As such, it has become a powerful tool in the study of Ca(2+) signaling pathway. Purification of Tg from Thapsia species requires repeated chromatographic steps with normal-phase alumina or silica and reverse phase chromatography. We thus developed an innovative procedure coupling high pressure automatized extraction with centrifugal partition chromatography allowing a fast and safe large-scale isolation of highly pure Tg, in two steps from Thapsia garganica L. roots. Comparison of influence of extraction procedures, storage conditions and harvesting areas on Tg content in different Algerian specimens of Thapsia garganica L. roots has been precised by mean of HPLC quantification procedure. Highest Tg content were found in the fresh material of the sample from Setif area.

  2. Investigation, comparison and design of chambers used in centrifugal partition chromatography on the basis of flow pattern and separation experiments.

    PubMed

    Schwienheer, C; Merz, J; Schembecker, G

    2015-04-17

    In centrifugal partition chromatography (CPC) the separation efficiency is mainly influenced by the hydrodynamic of mobile and stationary phase in the chambers. Thus, the hydrodynamic has to be investigated and understood in order to enhance a CPC separation run. Different chamber geometries have been developed in the past and the influence of several phase systems and CPC operating conditions were investigated for these chambers. However, a direct comparison between the different chamber types has not been performed yet. In order to investigate the direct influence of the chamber design on the hydrodynamic, several chamber designs - partially similar in geometry to commercial available designs - are investigated under standardized conditions in the present study. The results show the influence of geometrical aspects of the chamber design on the hydrodynamic and therewith, on the separation efficiency. As a conclusion of the present study, some ideas for an optimal chamber design for laboratory and industrial purpose are proposed.

  3. Centrifugal precipitation chromatography.

    PubMed

    Ito, Yoichiro; Qi, Lin

    2010-01-15

    Centrifugal precipitation chromatography separates analytes according their solubility in ammonium sulfate (AS) solution and other precipitants. The separation column is made from a pair of long spiral channels partitioned with a semipermeable membrane. In a typical separation, concentrated ammonium sulfate is eluted through one channel while water is eluted through the other channel in the opposite direction. This countercurrent process forms an exponential AS concentration gradient through the water channel. Consequently, protein samples injected into the water channel is subjected to a steadily increasing AS concentration and at the critical AS concentration they are precipitated and deposited in the channel bed by the centrifugal force. Then the chromatographic separation is started by gradually reducing the AS concentration in the AS channel which lowers the AS gradient concentration in the water channel. This results in dissolution of deposited proteins which are again precipitated at an advanced critical point as they move through the channel. Consequently, proteins repeat precipitation and dissolution through a long channel and finally eluted out from the column in the order of their solubility in the AS solution. The present method has been successfully applied to a number of analytes including human serum proteins, recombinant ketosteroid isomerase, carotenoid cleavage enzymes, plasmid DNA, polysaccharide, polymerized pigments, PEG-protein conjugates, etc. The method is capable to single out the target species of proteins by affinity ligand or immunoaffinity separation.

  4. Selection of operating parameters on the basis of hydrodynamics in centrifugal partition chromatography for the purification of nybomycin derivatives.

    PubMed

    Adelmann, S; Baldhoff, T; Koepcke, B; Schembecker, G

    2013-01-25

    The selection of solvent systems in centrifugal partition chromatography (CPC) is the most critical point in setting up a separation. Therefore, lots of research was done on the topic in the last decades. But the selection of suitable operating parameters (mobile phase flow rate, rotational speed and mode of operation) with respect to hydrodynamics and pressure drop limit in CPC is still mainly driven by experience of the chromatographer. In this work we used hydrodynamic analysis for the prediction of most suitable operating parameters. After selection of different solvent systems with respect to partition coefficients for the target compound the hydrodynamics were visualized. Based on flow pattern and retention the operating parameters were selected for the purification runs of nybomycin derivatives that were carried out with a 200 ml FCPC(®) rotor. The results have proven that the selection of optimized operating parameters by analysis of hydrodynamics only is possible. As the hydrodynamics are predictable by the physical properties of the solvent system the optimized operating parameters can be estimated, too. Additionally, we found that dispersion and especially retention are improved if the less viscous phase is mobile.

  5. Preparative separation of sesamin and sesamolin from defatted sesame meal via centrifugal partition chromatography with consecutive sample injection.

    PubMed

    Jeon, Je-Seung; Park, Chae Lee; Syed, Ahmed Shah; Kim, Young-Mi; Cho, Il Je; Kim, Chul Young

    2016-02-01

    A preparative separation method using consecutive sample injection centrifugal partition chromatography (CPC) was developed to obtain sesamin and sesamolin from defatted sesame meal extracts. A two-phase solvent system consisting of n-hexane-ethyl acetate-methanol-water (8:2:8:2, v/v) was applied in reversed-phase mode (descending mode). Preliminary experiments with an SCPC-100 (column volume: 100mL) were performed to select the appropriate two-phase solvent system and sample injection times; these parameters were then used with an SCPC-1000 (column volume: 1000mL) in a 10-fold scale-up preparative run. A sample containing 3g of crude extract was consecutively injected four times onto the SCPC-1000, which yielded 328mg of sesamin and 168mg of sesamolin. These compounds were analyzed by high-performance liquid chromatography and determined to have purities of 95.6% and 93.9%, respectively. Sesamin and sesamolin (30μM) increased antioxidant response element (ARE) luciferase activity 2.6-fold and 1.9-fold, respectively.

  6. Preparative isolation and purification of phlorotannins from Ecklonia cava using centrifugal partition chromatography by one-step.

    PubMed

    Lee, Ji-Hyeok; Ko, Ju-Young; Oh, Jae-Young; Kim, Chul-Young; Lee, Hee-Ju; Kim, Jaeil; Jeon, You-Jin

    2014-09-01

    Various bioactive phlorotannins of Ecklonia cava (e.g., dieckol, eckol, 6,6-bieckol, phloroglucinol, phloroeckol, and phlorofucofuroeckol-A) are reported. However, their isolation and purification are not easy. Centrifugal partition chromatography (CPC) can be used to efficiently purify the various bioactive-compounds efficiently from E. cava. Phlorotannins are successfully isolated from the ethyl acetate (EtOAc) fraction of E. cava by CPC with a two-phase solvent system comprising n-hexane:EtOAc:methanol:water (2:7:3:7, v/v) solution. The dieckol (fraction I, 40.2mg), phlorofucofuroeckol-A (fraction III, 31.1mg), and fraction II (34.1mg) with 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are isolated from the crude extract (500 mg) by a one-step CPC system. The purities of the isolated dieckol and phlorofucofuroeckol-A are ⩾90% according to high performance liquid chromatography (HPLC) and electrospray ionization multi stage tandem mass spectrometry analyses. The purified 2,7-phloroglucinol-6,6-bieckol and pyrogallol-phloroglucinol-6,6-bieckol are collected from fraction II by recycle-HPLC. Thus, the CPC system is useful for easy and simple isolation of phlorotannins from E. cava.

  7. Selective enrichment in bioactive compound from Kniphofia uvaria by super/subcritical fluid extraction and centrifugal partition chromatography.

    PubMed

    Duval, Johanna; Destandau, Emilie; Pecher, Virginie; Poujol, Marion; Tranchant, Jean-François; Lesellier, Eric

    2016-05-20

    Nowadays, a large portion of synthetic products (active cosmetic and therapeutic ingredients) have their origin in natural products. Kniphofia uvaria is a plant from Africa which has proved in the past by in-vivo tests an antioxidant activity due to compounds present in roots. Recently, we have observed anthraquinones in K. uvaria seeds extracts. These derivatives are natural colorants which could have interesting bioactive potential. The aim of this study was to obtain an extract enriched in anthraquinones from K. uvaria seeds which mainly contains glycerides. First, the separation of the seed compounds was studied by using supercritical fluid chromatography (SFC) in the goal to provide a rapid quantification method of these bioactive compounds. A screening of numerous polar stationary phases was achieved for selecting the most suited phase to the separation of the four anthraquinones founded in the seeds. A gradient elution was optimized for improving the separation of the bioactive compounds from the numerous other families of major compounds of the extracts (fatty acids, di- and triglycerides). Besides, a non-selective and green Supercritical Fluid Extraction (SFE) with pure CO2 was applied to seeds followed by a Centrifugal Partition Chromatography (CPC). The CPC system was optimized by using the Arizona phase system, to enrich the extract in anthraquinones. Two systems were selected to isolate the bioactive compounds from the oily extract with varied purity target. The effect of the injection mode for these very viscous samples was also studied. Finally, in order to directly apply a selective process of extraction to the seeds, the super/subcritical fluid extraction was optimized to increase the anthraquinone yield in the final extract, by studying varied modifier compositions and nature, as well as different temperatures and backpressures. Conditions suited to favour an enrichment factor bases on the ratio of anthraquinone and trilycerides extracted are

  8. On-line hyphenation of centrifugal partition chromatography and high pressure liquid chromatography for the fractionation of flavonoids from Hippophaë rhamnoides L. berries.

    PubMed

    Michel, Thomas; Destandau, Emilie; Elfakir, Claire

    2011-09-09

    Centrifugal Partition Chromatography (CPC), a liquid-liquid preparative chromatography using two immiscible solvent systems, benefits from numerous advantages for the separation or purification of synthetic or natural products. This study presents the on-line hyphenation of CPC-Evaporative Light Scattering Detector (CPC-ELSD) with High Performance Liquid Chromatography-UV (HPLC-UV) for the fractionation of flavonols from a solvent-free microwave extract of sea buckthorn (Hippophaë rhamnoides L., Elaeagnaceae) berries. An Arizona G system was used for the fractionation of flavonoids by CPC and a fused core Halo C18 column allowed the on-line analyses of collected fractions by HPLC. The on-line CPC/HPLC procedure allowed the simultaneous fractionation step at preparative scale combined with the HPLC analyses which provide direct fingerprint of collected fractions. Thus the crude extract was simplified and immediate information on the composition of fractions could be obtained. Furthermore, this methodology reduced the time of post-fractionation steps and facilitated identification of main molecules by Mass Spectrometry (MS). Rutin, isorhamnetin-3-O-rutinoside, isorhamnetin-3-O-glucoside, quercetin-3-O-glucoside, isorhamnetin-rhamnoside, quercetin and isorhamnetin were identified. CPC-ELSD/HPLC-UV could be considered as a high-throughput technique for the guided fractionation of bioactive natural products from complex crude extracts.

  9. Study of the separation limits of continuous solid support free liquid-liquid chromatography: separation of capsaicin and dihydrocapsaicin by centrifugal partition chromatography.

    PubMed

    Goll, Johannes; Frey, Andreas; Minceva, Mirjana

    2013-04-05

    Sequential centrifugal partition chromatography (sCPC) is a cyclic solid support-free liquid-liquid chromatographic process, in which a continuously introduced feed mixture is separated into two sequentially collected product streams. The few experimental demonstrations of this concept already revealed its potential for the preparative separation of pharmaceuticals and fine chemicals. In this work not only the possibilities, but also the limits of the sCPC technology are explored. A feed mixture consisting of capsaicin and dihydrocapsaicin, whose molecular structure differs in only one double bond, was selected for this purpose. The sCPC unit operating parameters needed for a complete separation of the feed mixture were selected using the recently published approach, which uses the partition coefficient of the feed components and the hydrodynamic characteristics of the system as input data. A complete separation of capsaicin and dihydrocapsaicin with the solvent system heptane/ethyl acetate/methanol/water:1/1/1/1 (v/v/v/v) was achieved, although the separation factor was only 1.32. The sCPC unit separation performance was successfully simulated using the cell model.

  10. Computational solvent system screening for the separation of tocopherols with centrifugal partition chromatography using deep eutectic solvent-based biphasic systems.

    PubMed

    Bezold, Franziska; Weinberger, Maria E; Minceva, Mirjana

    2017-03-31

    Tocopherols are a class of molecules with vitamin E activity. Among those, α-tocopherol is the most important vitamin E source in the human diet. The purification of tocopherols involving biphasic liquid systems can be challenging since these vitamins are poorly soluble in water. Deep eutectic solvents (DES) can be used to form water-free biphasic systems and have already proven applicable for centrifugal partition chromatography separations. In this work, a computational solvent system screening was performed using the predictive thermodynamic model COSMO-RS. Liquid-liquid equilibria of solvent systems composed of alkanes, alcohols and DES, as well as partition coefficients of α-tocopherol, β-tocopherol, γ-tocopherol, and σ-tocopherol in these biphasic solvent systems were calculated. From the results the best suited biphasic solvent system, namely heptane/ethanol/choline chloride-1,4-butanediol, was chosen and a batch injection of a tocopherol mixture, mainly consisting of α- and γ-tocopherol, was performed using a centrifugal partition chromatography set up (SCPE 250-BIO). A separation factor of 1.74 was achieved for α- and γ-tocopherol.

  11. Immunoaffinity centrifugal precipitation chromatography.

    PubMed

    Qi, Lin; Ito, Yoichiro

    2007-06-01

    Purification of proteins based on immunoaffinity has been performed using a solid support coated with antibody against the target proteins. The method requires immobilizing the antibody onto the solid support using protein A or G, and has a risk of adsorptive loss of target proteins onto the solid support. Centrifugal precipitation chromatography has been successfully used to purify enzymes, such as ketosteroid isomerase and hyaluronidase without the use of solid support. The purpose of this study is to demonstrate that immunoaffinity centrifugal precipitation chromatography is capable of isolating an antigen by exploiting antigen-antibody binding. The separation was initiated by filling both channels with 40% saturated ammonium sulfate (AS) of pH 4-4.5 followed by loading 20 microl of human plasma (National Institutes of Health blood bank) mixed with 2 mg of rabbit anti-HSA (human serum protein) antibody (Sigma). Then, the sample channel was eluted with water at 0.03 ml/min and AS channel with 40% AS solution of pH 4-4.5 at 1 ml/min until all non-binding components were eluted. Then, the releasing reagent (50% AS solution containing 0.5 M glycine and 10% ammonium hydroxide at pH 10) was introduced through the AS channel to release the target protein (HSA). The retained antibody was recovered by eluting the sample channel with water at 1 ml/min. A hollow fiber membrane device at the outlet (MicroKros, Spectrum, New Brunswick, NJ, USA) was provided on-line dialysis of the eluent before fractions were collected, so that the fractions could be analyzed by SDS-PAGE (sodium dodecyl sulfate - polyacrylamide gel electrophoresis) without further dialysis. The current method does not require immobilizing the antibody onto a matrix, which is used by the conventional immunoaffinity chromatography. This method ensures full recovery of the antigen and antibody, and it may be applied to purification of other proteins.

  12. Phase system selection with fractional factorial design for purification of recombinant cyanovirin-N from a hydroponic culture medium using centrifugal partition chromatography.

    PubMed

    Grudzień, Łukasz; Madeira, Luisa; Fisher, Derek; Ma, Julian; Garrard, Ian

    2013-04-12

    Centrifugal partition chromatography (CPC) with an aqueous two-phase system (ATPS) was used to purify recombinant cyanovirin-N (CV-N) from other proteins which were co-secreted into a hydroponic plant medium in a rhizosecretion process. To achieve satisfactory protein concentration, the purification was preceded by ultrafiltration performed on a 5 kDa filter. ATPS, because of their gentle nature, were selected as the phase system for CPC. A systematic phase system selection was applied. This involved studying the effect of seven parameters of ATPS: polymer type, salt type, the polymer and salt concentration, the polymer molecular weight, pH, and presence of two additional salts; NaCl and NaClO4, which all together gave 320 combinations. design of experiment (DoE) software allowed the reduction of this number to 46. Having tested partitioning of cyanovirin-N and impurities in 46 ATPS, the three best potential phase systems generated by the programme were then tested on the CPC. Out of these three, 13/13% PEG4000 sodium phosphate, pH 3.0, proved to be most effective phase system in the purification of cyanovirin-N, judged by ELISA and SDS-PAGE analysis, as it eliminated most of the impurities from the final cyanovirin-N preparation.

  13. Concentration and selective fractionation of an antihypertensive peptide from an alfalfa white proteins hydrolysate by mixed ion-exchange centrifugal partition chromatography.

    PubMed

    Boudesocque, Leslie; Kapel, Romain; Paris, Cedric; Dhulster, Pascal; Marc, Ivan; Renault, Jean-Hugues

    2012-09-15

    This article reports a promising use of the mixed ion-exchange centrifugal partition chromatography (MIXCPC) technique in the field of downstream processes. A complex alfalfa white protein concentrate hydrolysate (AWPC hydrolysate) showing anti-hypertensive properties was successfully fractionated by MIXCPC to yield a L-valyl-L-tryptophan (VW) enriched fraction in one run. This dipeptide shows an interesting anti-angiotensin converting enzyme (anti-ACE) activity. An analytical method based on RP-LC/MS-MS was developed to quantify the target VW peptide in both the starting material and the enriched fractions. The best results for the MIXCPC fractionation were obtained by the combined use of the quaternary biphasic solvent system, methyl-tert-butylether/acetonitrile/n-butanol/water (2:1:2:5, v/v) in the descending mode, of the lipophilic di(2-ethylhexyl)phosphoric acid (DEHPA) cation-exchanger with an exchanger (DEHPA)/peptides ratio of 15, and of two displacers: calcium chloride and hydrochloric acid. The complexity of the starting material involved the selectivity optimization by splitting the stationary phase into two sections that differed by their triethylamine concentration. From 1g of AWPC hydrolysate containing 0.26% of VW, 30.7 mg of a VW enriched fraction were recovered with a purity of 10.9%, corresponding to a purification factor of 41 and a recovery of 97%.

  14. Employment of High-Performance Thin-Layer Chromatography for the Quantification of Oleuropein in Olive Leaves and the Selection of a Suitable Solvent System for Its Isolation with Centrifugal Partition Chromatography.

    PubMed

    Boka, Vasiliki-Ioanna; Argyropoulou, Aikaterini; Gikas, Evangelos; Angelis, Apostolis; Aligiannis, Nektarios; Skaltsounis, Alexios-Leandros

    2015-11-01

    A high-performance thin-layer chromatographic methodology was developed and validated for the isolation and quantitative determination of oleuropein in two extracts of Olea europaea leaves. OLE_A was a crude acetone extract, while OLE_AA was its defatted residue. Initially, high-performance thin-layer chromatography was employed for the purification process of oleuropein with fast centrifugal partition chromatography, replacing high-performance liquid-chromatography, in the stage of the determination of the distribution coefficient and the retention volume. A densitometric method was developed for the determination of the distribution coefficients, KC = CS/CM. The total concentrations of the target compound in the stationary phase (CS) and in the mobile phase (CM) were calculated by the area measured in the high-performance thin-layer chromatogram. The estimated Kc was also used for the calculation of the retention volume, VR, with a chromatographic retention equation. The obtained data were successfully applied for the purification of oleuropein and the experimental results confirmed the theoretical predictions, indicating that high-performance thin-layer chromatography could be an important counterpart in the phytochemical study of natural products. The isolated oleuropein (purity > 95%) was subsequently used for the estimation of its content in each extract with a simple, sensitive and accurate high-performance thin-layer chromatography method. The best fit calibration curve from 1.0 µg/track to 6.0 µg/track of oleuropein was polynomial and the quantification was achieved by UV detection at λ 240 nm. The method was validated giving rise to an efficient and high-throughput procedure, with the relative standard deviation % of repeatability and intermediate precision not exceeding 4.9% and accuracy between 92% and 98% (recovery rates). Moreover, the method was validated for robustness, limit of quantitation, and limit of detection. The amount of oleuropein for

  15. Liquid centrifugation for nuclear waste partitioning

    SciTech Connect

    Bowman, C.D.

    1992-03-11

    The performance of liquid centrifugation for nuclear waste partitioning is examined for the Accelerator Transmutation of Waste Program currently under study at the Los Alamos National Laboratory. Centrifugation might have application for the separation of the LiF-BeF{sub 2} salt from heavier radioactive materials fission product and actinides in the separation of fission product from actinides, in the isotope separation of fission-product cesium before transmutation of the {sup 137}Cs and {sup 135}Cs, and in the removal of spallation product from the liquid lead target. It is found that useful chemical separations should be possible using existing materials for the centrifuge construction for all four cases with the actinide fraction in fission product perhaps as low as 1 part in 10{sup 7} and the fraction of {sup 137}CS in {sup 133}Cs being as low as a few parts in 10{sup 5}. A centrifuge cascade has the advantage that it can be assembled and operated as a completely closed system without a waste stream except that associated with maintenance or replacement of centrifuge components.

  16. Intensified extraction of ionized natural products by ion pair centrifugal partition extraction.

    PubMed

    Hamzaoui, Mahmoud; Hubert, Jane; Hadj-Salem, Jamila; Richard, Bernard; Harakat, Dominique; Marchal, Luc; Foucault, Alain; Lavaud, Catherine; Renault, Jean-Hugues

    2011-08-05

    The potential of centrifugal partition extraction (CPE) combined with the ion-pair (IP) extraction mode to simultaneously extract and purify natural ionized saponins from licorice is presented in this work. The design of the instrument, a new laboratory-scale Fast Centrifugal Partition Extractor (FCPE300(®)), has evolved from centrifugal partition chromatography (CPC) columns, but with less cells of larger volume. Some hydrodynamic characteristics of the FCPE300(®) were highlighted by investigating the retention of the stationary phase under different flow rate conditions and for different biphasic solvent systems. A method based on the ion-pair extraction mode was developed to extract glycyrrhizin (GL), a biologically active ionic saponin naturally present in licorice (Glycyrrhiza glabra L., Fabaceae) roots. The extraction of GL was performed at a flow rate of 20 mL/min in the descending mode by using the biphasic solvent system ethyl acetate/n-butanol/water in the proportions 3/2/5 (v/v/v). Trioctylmethylammonium with chloride as a counter-ion (Al336(®)) was used as the anion extractant in the organic stationary phase and iodide, with potassium as counter-ion, was used as the displacer in the aqueous mobile phase. From 20 g of a crude extract of licorice roots, 2.2g of GL were recovered after 70 min, for a total process duration of 90 min. The combination of the centrifugal partition extractor with the ion-pair extraction mode (IP-CPE) offers promising perspectives for industrial applications in the field of natural product isolation or for the fractionation of natural complex mixtures.

  17. Strong ion exchange in centrifugal partition extraction (SIX-CPE): effect of partition cell design and dimensions on purification process efficiency.

    PubMed

    Hamzaoui, Mahmoud; Hubert, Jane; Reynaud, Romain; Marchal, Luc; Foucault, Alain; Renault, Jean-Hugues

    2012-07-20

    The aim of this article was to evaluate the influence of the column design of a hydrostatic support-free liquid-liquid chromatography device on the process efficiency when the strong ion-exchange (SIX) development mode is used. The purification of p-hydroxybenzylglucosinolate (sinalbin) from a crude aqueous extract of white mustard seeds (Sinapis alba L.) was achieved on two types of devices: a centrifugal partition chromatograph (CPC) and a centrifugal partition extractor (CPE). They differ in the number, volume and geometry of their partition cells. The SIX-CPE process was evaluated in terms of productivity and sinalbin purification capability as compared to previously optimized SIX-CPC protocols that were carried out on columns of 200 mL and 5700 mL inner volume, respectively. The objective was to determine whether the decrease in partition cell number, the increase in their volume and the use of a "twin cell" design would induce a significant increase in productivity by applying higher mobile phase flow rate while maintaining a constant separation quality. 4.6g of sinalbin (92% recovery) were isolated from 25 g of a crude white mustard seed extract, in only 32 min and with a purity of 94.7%, thus corresponding to a productivity of 28 g per hour and per liter of column volume (g/h/LV(c)). Therefore, the SIX-CPE process demonstrates promising industrial technology transfer perspectives for the large-scale isolation of ionized natural products.

  18. In-situ protein determination to monitor contamination in a centrifugal partition chromatograph.

    PubMed

    Bouiche, Feriel; Faure, Karine

    2017-05-15

    Centrifugal partition chromatography (CPC) works with biphasic liquid systems including aqueous two-phase systems. Metallic rotors are able to retain an aqueous stationary phase able to purify proteins. But the adhesion of proteins to solid surface may pose a cross-contamination risk during downstream processes. So it is of utmost importance to ensure the cleanliness of the equipment and detect possible protein contamination in a timely manner. Thereby, a direct method that allows the determination of the effective presence of proteins and the extent of contamination in the metallic CPC rotors was developed. This in-situ method is derived from the Amino Density Estimation by Colorimetric Assay (ADECA) which is based on the affinity of a dye, Coomassie Brillant Blue (CBB), with protonated N(+) groups of the proteins. In this paper, the ADECA method was developed dynamically, on a 25 mL stainless-steel rotor with various extents of protein contaminations using bovine serum albumin (BSA) as a fouling model. The eluted CBB dye was quantified and found to respond linearly to BSA contamination up to 70 mg injected. Limits of detection and quantification were recorded as 0.9 mg and 3.1 mg, respectively. While the non-specific interactions between the dye and the rotor cannot currently be neglected, this method allows for in situ determination of proteins contamination and should contribute to the development of CPC as a separation tool in protein purification processes.

  19. Novel Design for Centrifugal Countercurrent Chromatography: I. Zigzag Toroidal Column

    PubMed Central

    Yang, Yi; Aisa, Haji Akber; Ito, Yoichiro

    2009-01-01

    The toroidal coil using an equilateral triangular core has improved both retention of the stationary phase and peak resolution of the conventional toroidal coil in centrifugal countercurrent chromatography. To further improve the retention of stationary phase and peak resolution, a novel zigzag toroidal coil was designed and the performance of the system was evaluated at various flow rates. The results indicated that both retention of stationary phase and peak resolution were improved as the flow rate was decreased. Modification of the tubing by pressing at given intervals with a pair of pliers improved the peak resolution without increasing the column pressure. All these separations were performed under low column pressure indicating the separation can be further improved by increasing the column length and/or revolution speed without damaging the separation column. PMID:20046954

  20. CENTRIFUGE

    DOEpatents

    Rushing, F.C.

    1960-09-01

    A vibration damping mechanism for damping vibration forces occurring during the operation of a centrifuge is described. The vibration damping mechanism comprises a plurality of nested spaced cylindrical elements surrounding the rotating shaft of the centrifuge. Some of the elements are held substantially stationary while the others are held with respect to a pair of hearings spaced along the rotating shaft. A fluid is retained about the cylindrical elements.

  1. Centrifugal partition extraction, a new method for direct metabolites recovery from culture broth: case study of torularhodin recovery from Rhodotorula rubra.

    PubMed

    Ungureanu, Camelia; Marchal, Luc; Chirvase, Ana Aurelia; Foucault, Alain

    2013-03-01

    Centrifugal partition extraction (CPE), close to centrifugal partition chromatography, put in contact in a continuous way two immiscible liquid phases. This work presents early experiments on CPE use for solid-liquid-liquid extraction. It was applied to the direct treatment of culture broth for metabolites recovery. Torularhodin is one of the carotenoid pigments produced by the yeast Rhodotorula sp., with a terminal carboxylic group considered nowadays as a powerful antioxidant to be included in food and drugs formulations. Torularhodin was extracted from Rhodotorula rubra ICCF 209 cells by CPE. The recovery of torularhodin reaches 74 μg/g of biomass i.e. 294 μg/L of culture medium. The efficiency of the extraction step increased with the operating flow rate. The extraction yield could reach 91% with a contact time lower than 2 min. A 300 mL apparatus allowed a feed at 90 mL/min. The technique is proposed for extraction or sample preparation before analysis.

  2. Multi-stage mixer-settler planet centrifuge. Preliminary studies on partition of macromolecules with organic-aqueous and aqueous-aqueous two-phase solvent systems.

    PubMed

    Ito, Y; Zhang, T Y

    1988-03-11

    A rotary-seal-free planetary centrifuge holds a separation column which consists of multiple partition units (ca. 200) connected in series with transfer tubes. In the cavity of each partition unit the transfer tube extends to form a mixer which vibrates to stir the contents under an oscillating force field generated by the planetary motion of the centrifuge. Consequently, solutes locally introduced at the inlet of the column are subjected to an efficient partition process in each partition unit and separated according to their partition coefficients. The mixer tube equipped with a flexible silicone rubber joint was found to produce excellent results for partition with viscous polymer phase systems. The capability of the method was demonstrated on separation of cytochrome c and lysozyme using a PEG-aqueous dibasic potassium phosphate-aqueous two-phase solvent system.

  3. Application of annular centrifugal contactors in the hot test of the improved total partitioning process for high level liquid waste.

    PubMed

    Duan, Wuhua; Chen, Jing; Wang, Jianchen; Wang, Shuwei; Feng, Xiaogui; Wang, Xinghai; Li, Shaowei; Xu, Chao

    2014-08-15

    High level liquid waste (HLLW) produced from the reprocessing of the spent nuclear fuel still contains moderate amounts of uranium, transuranium (TRU) actinides, (90)Sr, (137)Cs, etc., and thus constitutes a permanent hazard to the environment. The partitioning and transmutation (P&T) strategy has increasingly attracted interest for the safe treatment and disposal of HLLW, in which the partitioning of HLLW is one of the critical technical issues. An improved total partitioning process, including a TRPO (tri-alkylphosphine oxide) process for the removal of actinides, a CESE (crown ether strontium extraction) process for the removal of Sr, and a CECE (calixcrown ether cesium extraction) process for the removal of Cs, has been developed to treat Chinese HLLW. A 160-hour hot test of the improved total partitioning process was carried out using 72-stage 10-mm-dia annular centrifugal contactors (ACCs) and genuine HLLW. The hot test results showed that the average DFs of total α activity, Sr and Cs were 3.57 × 10(3), 2.25 × 10(4) and 1.68 × 10(4) after the hot test reached equilibrium, respectively. During the hot test, 72-stage 10-mm-dia ACCs worked stable, continuously with no stage failing or interruption of the operation.

  4. Using Aspen to Teach Chromatographic Bioprocessing: A Case Study in Weak Partitioning Chromatography for Biotechnology Applications

    ERIC Educational Resources Information Center

    Evans, Steven T.; Huang, Xinqun; Cramer, Steven M.

    2010-01-01

    The commercial simulator Aspen Chromatography was employed to study and optimize an important new industrial separation process, weak partitioning chromatography. This case study on antibody purification was implemented in a chromatographic separations course. Parametric simulations were performed to investigate the effect of operating parameters…

  5. Novel design for centrifugal counter-current chromatography: VI. Ellipsoid column.

    PubMed

    Gu, Dongyu; Yang, Yi; Xin, Xuelei; Aisa, Haji Akber; Ito, Yoichiro

    2015-01-01

    A novel ellipsoid column was designed for centrifugal counter-current chromatography. Performance of the ellipsoid column with a capacity of 3.4 mL was examined with three different solvent systems composed of 1-butanol-acetic acid-water (4:1:5, v/v) (BAW), hexane-ethyl acetate-methanol-0.1 M HCl (1:1:1:1, v/v) (HEMH), and 12.5% (w/w) PEG1000 and 12.5% (w/w) dibasic potassium phosphate in water (PEG-DPP) each with suitable test samples. In dipeptide separation with BAW system, both stationary phase retention (Sf) and peak resolution (Rs) of the ellipsoid column were much higher at 0° column angle (column axis parallel to the centrifugal force) than at 90° column angle (column axis perpendicular to the centrifugal force), where elution with the lower phase at a low flow rate produced the best separation yielding Rs at 2.02 with 27.8% Sf at a flow rate of 0.07 ml/min. In the DNP-amino acid separation with HEMW system, the best results were obtained at a flow rate of 0.05 ml/min with 31.6% Sf yielding high Rs values at 2.16 between DNP-DL-glu and DNP-β-ala peaks and 1.81 between DNP-β-ala and DNP-L-ala peaks. In protein separation with PEG-DPP system, lysozyme and myolobin were resolved at Rs of 1.08 at a flow rate of 0.03 ml/min with 38.9% Sf. Most of those Rs values exceed those obtained from the figure-8 column under similar experimental conditions previously reported.

  6. New 18-l process-scale counter-current chromatography centrifuge.

    PubMed

    Sutherland, Ian; Hewitson, Peter; Ignatova, Svetlana

    2009-05-08

    A new Dynamic Extractions Maxi-counter-current chromatography (CCC) centrifuge with a column volume of 18-l has been installed in the Advanced Bioprocessing Centre at Brunel. This instrument has four times the capacity of the 4.6-l Maxi-CCC centrifuge which has been operating robustly for 3 years. Tests using the model sample system benzyl alcohol and p-cresol with a heptane:ethyl acetate:methanol:water (HEMWat) phase system (1.4:0.1:0.5:1.0) show that resolution is almost double with this new high capacity device. Commissioning tests with a mixture of caffeine, K(D)=0.21; ferulic acid, K(D)=0.82; umbelliferone, K(D)=1.2 and vanillin, K(D)=1.49 using a HEMWat phase system of 1:1.5:1:1.5 on the 9-l column show that resolutions equivalent to analytical instruments will be possible using the full 18-l capacity. They also show that predictable scale-up from simple test tube tests is feasible with knowledge of the stationary phase retention for the planned process scale run.

  7. Preparation and application of reversed phase chromatorotor for the isolation of natural products by centrifugal preparative chromatography

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A method of preparation of Chromatorotor or plates with a reversed phase (RP) solid silica gel sorbent layer has been developed for preparative centrifugal chromatography. The RP-rotor plates consist of binder free RP solid SiO2 sorbent layers of different thicknesses paked between two supported cir...

  8. Centrifugal precipitation chromatography, a powerful technique for the isolation of active enzymes from tea leaves (Camellia sinensis).

    PubMed

    Baldermann, Susanne; Fleischmann, Peter; Bolten, Mareike; Watanabe, Naoharu; Winterhalter, Peter; Ito, Yoichiro

    2009-05-08

    Centrifugal precipitation chromatography was developed approximately 10 years ago. In contrast to other counter-current chromatographic techniques, the centrifugal precipitation chromatography system is operated with two mutually miscible solutions separated by a cut-off membrane. Centrifugal precipitation chromatography was firstly introduced for the separation of proteins using an ammonium sulfate gradient. In this study we describe a novel approach using solvent-based protein precipitation for the isolation of active plant enzymes from tea leaves (Camellia sinensis) by centrifugal precipitation chromatography. We developed a gradient based on acetone and Tris-buffer, because the biological activity of carotenases in tea leaves cannot be preserved in the presence of ammonium sulfate. Parameters such as the critical solvent concentration, flow rate, buffer concentration, and sample load were determined and/or optimized. Subsequently, the newly developed separation protocol was successfully used for the isolation of active carotenoid cleavage enzymes from tea leaves. The isolated enzymes showed high enzymatic activities and purities and could be directly used for enzymatic assays and structure elucidation.

  9. Determination of descriptors for fragrance compounds by gas chromatography and liquid-liquid partition.

    PubMed

    Karunasekara, Thushara; Poole, Colin F

    2012-04-27

    Retention factors on a minimum of eight stationary phases at various temperatures by gas-liquid chromatography and liquid-liquid partition coefficients for five totally organic biphasic systems were combined to estimate descriptors for 28 fragrance compounds with an emphasis on compounds that are known or potential allergens. The descriptors facilitated the estimation of several properties of biological and environmental interest (sensory irritation threshold, odor detection threshold, nasal pungency threshold, skin permeability from water, skin-water partition coefficients, octanol-water partition coefficients, absorption by air particles, adsorption by diesel soot particles, air-water partition coefficients, and adsorption by film water). The descriptors are suitable for use in the solvation parameter model and facilitate the estimation of a wide range of physicochemical, chromatographic, biological, and environmental properties using existing models.

  10. Partition Coefficients of Organic Compounds in New Imidazolium and Tetralkylammonium Based Ionic Liquids Using Inverse Gas Chromatography

    SciTech Connect

    Mutelet, Fabrice; Revelli, Anne-Laure; Jaubert, Jean-Noel; Sprunger, Laura; Acree, William; Baker, Gary A

    2010-01-01

    Partition coefficients of 51 organic compounds in two ionic liquids (IL), 1-ethyl-3-methylimidazolium dicyanamide and trimethylhexylammonium bis((trifluoromethyl)sulfonyl)amide, were measured using inverse gas chromatography from (322.5 to 352.5) K. These partition coefficients were converted into water-to-IL partition coefficients using the corresponding gas-to-water partition coefficients. Both sets of partition coefficients were analyzed using the Abraham solvation parameter model with cation-specific and anionspecific equation coefficients. The derived equations correlated the experimental gas-to-IL and water-to-IL partition coefficient data to within (0.12 and 0.14) log units, respectively.

  11. New small-scale cross-axis coil planet centrifuge. Partition efficiency and application to purification of bullfrog ribonuclease.

    PubMed

    Shinomiya, Kazufusa; Kobayashi, Hiroko; Inokuchi, Norio; Kobayashi, Koji; Oshima, Hisashi; Kitanaka, Susumu; Yanagidaira, Kazuhiro; Sasaki, Haruo; Muto, Minoru; Okano, Michiharu; Ito, Yoichiro

    2007-06-01

    The new small-scale cross-axis coil planet centrifuge (X-axis CPC) previously designed and fabricated in our laboratory has a distinctive feature such that four separation columns of similar weight are mounted symmetrically around the rotary frame to achieve stable balancing of the centrifuge under a high revolution speed. In this column layout, neighboring columns must be rotated in the opposite direction if viewed from the center of the centrifuge to avoid twisting the interconnecting flow tubes. The effect of rotational direction of the columns on the partition efficiency was evaluated with separation of a set of test samples such as cytochrome c, myoglobin, and lysozyme using an aqueous-aqueous polymer phase system composed of 12.5% (w/w) polyethylene glycol (PEG) 1000 and 12.5% (w/w) dibasic potassium phosphate under 1000 rpm of column revolution. A series of experiments was performed using a set of two diagonally located columns (connected in series) each consisting of five coiled layers of 1 mm I.D. with a total capacity of 27.0 mL. Both right- and left-handed coils were tested each under the optimized conditions for choice of mobile phase and direction of the column rotation so that the satisfactory volume of the mobile phase was retained in the column by the aid of Archimedean screw effect. The results of these studies showed that one particular combination of handedness of the coil and direction of the rotation yielded the best peak resolution for each mobile phase. In order to demonstrate the capability of the apparatus, the purification of ribonuclease (RNase) from the extract of bullfrog egg, sialic acid binding lectin (cSBL), was carried out using both organic-aqueous and aqueous-aqueous polymer phase systems. When using the 16.0% (w/w) PEG 1000-6.3% (w/w) dibasic potassium phosphate-6.3% (w/w) monobasic potassium phosphate system, cSBL was successfully separated from other proteins present in the extract while commercial RNase A was eluted at near

  12. Partition coefficients of organic compounds in new imidazolium based ionic liquids using inverse gas chromatography.

    PubMed

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noël

    2009-06-05

    Partition coefficients of organic compounds in four ionic liquids: 1-ethanol-3-methylimidazolium tetrafluoroborate, 1-ethanol-3-methylimidazolium hexafluorophosphate, 1,3-dimethylimidazolium dimethylphosphate and 1-ethyl-3-methylimidazolium diethylphosphate were measured using inverse gas chromatography from 303.3 to 332.55K. The influence of gas-liquid and gas-solid interfacial adsorption of different solutes on ionic liquids was also studied. Most of the polar solutes were retained largely by partition while light hydrocarbons were retained predominantly by interfacial adsorption on the ionic liquids studied in this work. The solvation characteristics of the ionic liquids were evaluated using the Abraham solvation parameter model.

  13. Distribution ratio, distribution constant and partition coefficient. Countercurrent chromatography retention of benzoic acid.

    PubMed

    Berthod, Alain; Mekaoui, Nazim

    2011-09-09

    There is some confusion in chromatography between terms such as solute distribution ratio, distribution constant and partition coefficient. These terms are very precisely defined in the field of liquid-liquid systems and liquid-liquid extraction as well as in the field of chromatography with sometimes conflicting definitions. Countercurrent chromatography (CCC) is a chromatographic technique in which the stationary phase is a support-free liquid. Since the mobile phase is also liquid, biphasic liquid systems are used. This work focuses on the exact meaning of the terms since there are consequences on experimental results. The retention volumes of solutes in CCC are linearly related to their distribution ratios. The partition coefficient that should be termed (IUPAC recommendation) distribution constant is linked to a single definite species. Using benzoic acid that can dimerize in heptane and ionize in aqueous phase and an 18 mL hydrodynamic CCC column, the role and relationships between parameters and the consequences on experimental peak position and shape are discussed. If the heptane/water distribution constant (marginally accepted to be called partition coefficient) of benzoic acid is 0.2 at 20 °C and can be tabulated in books, its CCC measured distribution ratio or distribution coefficient can change between zero (basic aqueous mobile phase) and more than 25 (acidic aqueous mobile phase and elevated concentration). Benzoic acid distribution ratio and partition coefficient coincide only when both dimerization and ionization are quenched, i.e. at very low concentration and pH 2. It is possible to quench dimerization adding butanol in the heptane/water system. However, butanol additions also affect the partition coefficient of benzoic acid greatly by increasing it.

  14. Development of a modular virus clearance package for anion exchange chromatography operated in weak partitioning mode.

    PubMed

    Iskra, Timothy; Sacramo, Ashley; Gallo, Chris; Godavarti, Ranga; Chen, Shuang; Lute, Scott; Brorson, Kurt

    2015-01-01

    Anion exchange chromatography (AEX) operated under weak partitioning mode has been proven to be a powerful polishing step as well as a robust viral clearance step in Pfizer's monoclonal antibody (mAb) platform purification process. A multivariate design of experiment (DoE) study was conducted to understand the impact of operating parameters and feedstream impurity levels on viral clearance by weak partitioning mode AEX. Bacteriophage was used initially as a surrogate for neutral and acidic isoelectric point mammalian viruses (e.g., retrovirus and parvovirus). Five different mAbs were used in the evaluation of process parameters such as load challenge (both product and impurities), load pH, load conductivity, and contact time (bed height and flow-rate). The operating ranges obtained from phage clearance studies and Pfizer's historical data were used to define an appropriate operating range for a subsequent clearance study with model retrovirus and parvovirus. Both phage and virus clearance evaluations included feedstreams containing different levels of impurities such as high molecular mass species (HMMS), host cell proteins (HCPs), and host cell DNA. For all the conditions tested, over 5 log10 of clearance for both retrovirus and parvovirus was achieved. The results demonstrated that weak partitioning mode AEX chromatography is a robust step for viral clearance and has the potential to be included as part of the modular viral clearance approach.

  15. Centrifugal partition extraction in the pH-zone-refining displacement mode: an efficient strategy for the screening and isolation of biologically active phenolic compounds.

    PubMed

    Hamzaoui, Mahmoud; Renault, Jean-Hugues; Reynaud, Romain; Hubert, Jane

    2013-10-15

    Centrifugal partition extraction (CPE) was developed for the first time in the pH-zone-refining mode to fractionate a crude bark extract of the African tree Anogeissus leiocarpus Guill. & Perr. (Combretaceae). The fractionation process was performed at a flow rate of 20mL/min using a biphasic solvent system composed of methyl tert-butyl ether/acetonitrile/water (4:1:5, v/v/v) in the ascending mode. Sodium hydroxide (40mM) and trifluoroacetic acid (30mM) were used as retainer and displacer agents, respectively. In a single run of 67min, 3g of the initial crude extract were successfully separated into fractions selectively enriched in ionizable triterpenes, ellagic acid derivatives and flavonoids. The antioxidant potential of the initial crude extract, isolated compounds and fraction pools was also evaluated by using the 2,2-diphenyl-1-picrylhydrazyl (DPPH) stable free radical scavenging assay, providing an interesting view about the effect of the degree of substitution of ellagic acid derivatives on their radical scavenging activity. This study will demonstrate that centrifugal partition extraction used in the pH-zone-refining mode can be proposed as an efficient strategy for the rapid screening of natural phenolic compounds.

  16. Fabrication of chiral amino acid ionic liquid modified magnetic multifunctional nanospheres for centrifugal chiral chromatography separation of racemates.

    PubMed

    Liu, Yating; Tian, Ailin; Wang, Xiong; Qi, Jing; Wang, Fengkang; Ma, Ying; Ito, Yoichiro; Wei, Yun

    2015-06-26

    As the rapid development of nanotechnology, the magnetic nanospheres modified with special chiral selective ligands show a great potentiality in enantiomeric separation. In this study, magnetic nanospheres modified with task-specific chiral ionic liquid were designed for the separation of chiral amino acids. These modified magnetic nanospheres were effective in a direct chiral separation of five racemic amino acids (D- and L-cysteine, D- and L-arginine, D- and L-leucine, D- and L-glutamine and D- and L-tryptophan). Furthermore, a new online method for complete separation of the enantiomers via the magnetic nanospheres was established with centrifugal chiral chromatography using a spiral tube assembly mounted on a type-J coil planet centrifuge. One kind of chiral compounds, D- and L-tryptophan was resolved well using this method. These results demonstrated that the modified nanospheres display a good chiral recognition ability, and can be used as a potential material for chiral separation of various racemates.

  17. Structural and performance characteristics of representative anion exchange resins used for weak partitioning chromatography.

    PubMed

    Zhang, Shaojie; Iskra, Tim; Daniels, William; Salm, Jeffrey; Gallo, Christopher; Godavarti, Ranga; Carta, Giorgio

    2016-12-20

    Weak partitioning chromatography (WPC) has been proposed for the purification of monoclonal antibodies using an anion exchange (AEX) resin to simultaneously remove both acidic and basic protein impurities. Despite potential advantages, the relationship between resin structure and WPC performance has not been evaluated systematically. In this work, we determine the structure of representative AEX resins (Fractogel® EMD TMAE HiCap, Q Sepharose FF, and POROS 50 HQ) using transmission electron microscopy and inverse size exclusion chromatography and characterize protein interactions while operating these resins under WPC conditions using two mAb monomers, a mAb dimer, mAb multimers, and BSA as model products and impurities. We determine the isocratic elution behavior of the weakly bound monomer and dimer species and the adsorptive and mass transfer properties of the strongly bound multimers and BSA by confocal laser scanning microscopy. The results show that for each resin, using the product Kp value as guidance, salt, and pH conditions can be found where mAb multimers and BSA are simultaneously removed. Isocratic elution and adsorption mechanisms are, however, different for each resin and for the different components. Under WPC conditions, the Fractogel resin exhibited very slow diffusion of both mAb monomer and dimer species but fast adsorption for both mAb multimers and BSA with high capacity for BSA, while the Sepharose resin, because of its small pore size, was unable to effectively remove mAb multimers. The POROS resin was instead able to bind both multimers and BSA effectively, while exhibiting a greater resolution of mAb monomer and dimer species. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 2017.

  18. Improvement of microemulsion electrokinetic chromatography for measuring octanol-water partition coefficients.

    PubMed

    Xia, Zhining; Jiang, Xuemei; Mu, Xiaojing; Chen, Hua

    2008-02-01

    Microemulsion electrokinetic chromatography (MEEKC) has been used to indirectly measure octanol-water partition coefficients (log P(ow)) of compounds. In order to obtain an accurate log P(ow) value, the electrophoretic mobilities of the microemulsion phase (mu(me)) and the analyte (mu(eff)) in MEEKC must be accurately required. However, in conventional MEEKC, the shortage of obtaining mu(me) with a tracing method was discovered, and the influences of concentration, injection volume of analyte, and high electric field on measuring mu(eff) were also found. In this paper, a novel method called improved MEEKC (I-MEEKC) was developed to avoid the problems mentioned above. In I-MEEKC, a nonlinearity fitting program was used to obtain mu(me) to avoid the error from tracing mu(me); the extrapolating method was used to eliminate the effects of concentrations and injection volumes of analytes on mu(eff) measurement, and an enough stable microemulsion was selected to eliminate the effect of high electric field on mu(eff )measurement. Then the novel method was applied to estimate log P(ow) of uncharged compounds and charged pharmaceuticals compared to the conventional MEEKC. The log P(ow) of all analytes obtained by I-MEEKC agreed with those obtained by classical shake flask or literature values, the errors between them were within 0.1 logarithm units, better than the ones by conventional MEEKC.

  19. Evaluation of octanol-water partition coefficients using capillary gas chromatography with cold on-column injection

    SciTech Connect

    Haky, J.E.; Leja, B.

    1986-01-01

    A general procedure is described for the determination of the octanol-water partition coefficients (log P) of very lipophilic compounds by the shake flask method, employing the analytical technique of capillary gas chromatography with cold on-column injection. The solute and an internal reference with a known log P value are partitioned between the layers of an octanol-water mixture and their relative concentrations are determined by analysis of each phase, using highly standardized chromatographic conditions. The overall method is demonstrated to be convenient, reproducible, and useful for the determination of the partition coefficients of a wide variety of compounds with log P values as high as 5.7. 14 references, 1 figure, 1 table.

  20. In-coupled syringe assisted octanol-water partition microextraction coupled with high-performance liquid chromatography for simultaneous determination of neonicotinoid insecticide residues in honey.

    PubMed

    Vichapong, Jitlada; Burakham, Rodjana; Srijaranai, Supalax

    2015-07-01

    A simple and fast method namely in-coupled syringe assisted octanol-water partition microextraction combined with high performance liquid chromatography (HPLC) has been developed for the extraction, preconcentration and determination of neonicotinoid insecticide residues (e.g. imidacloprid, acetamiprid, clothianidin, thiacloprid, thiamethoxam, dinotefuran, and nitenpyram) in honey. The experimental parameters affected the extraction efficiency, including kind and concentration of salt, kind of disperser solvent and its volume, kind of extraction solvent and its volume, shooting times and extraction time were investigated. The extraction process was carried out by rapid shooting of two syringes. Therefore, rapid dispersion and mass transfer processes was created between phases, and thus affects the extraction efficiency of the proposed method. The optimum extraction conditions were 10.00 mL of aqueous sample, 10% (w/v) Na2SO4, 1-octanol (100µL) as an extraction solvent, shooting 4 times and extraction time 2min. No disperser solvent and centrifugation step was necessary. Linearity was obtained within the range of 0.1-3000 ngmL(-1), with the correlation coefficients greater than 0.99. The high enrichment factor of the target analytes was 100 fold and low limit of detection (0.25-0.50 ngmL(-1)) could be obtained. This proposed method has been successfully applied in the analysis of neonicotinoid residues in honey, and good recoveries in the range of 96.93-107.70% were obtained.

  1. Application of centrifugal precipitation chromatography and high-speed counter-current chromatography equipped with a spiral tubing support rotor for the isolation and partial characterization of carotenoid cleavage-like enzymes in Enteromorpha compressa (L.) Nees.

    PubMed

    Baldermann, Susanne; Mulyadi, Andriati N; Yang, Ziyin; Murata, Ariaka; Fleischmann, Peter; Winterhalter, Peter; Knight, Martha; Finn, Thomas M; Watanabe, Naoharu

    2011-10-01

    Centrifugal precipitation chromatography and a high-speed counter-current chromatography system equipped with a spiral tubing support rotor (spHSCCC) were successfully applied for the identification and isolation of carotenoid cleavage-like enzymes from Enteromorpha compressa (L.) Nees. This is the first study separating active enzymes from a complex natural matrix by spHSCCC. The target enzymes were identified after fractionation of the proteins in an acetone Tris-buffer gradient by centrifugal precipitation chromatography. Also, an aqueous two-phase solvent system consisting of PEG 1000 and mono- and dibasic potassium phosphate was used for the isolation of the enzymes by spHSCCC. The purified fractions contained two proteins of 65 and 72 kDa, respectively. The enzymes could cleave β-carotene and β-apo-8'-carotenal to produce β-ionone.

  2. Biopartitioning micellar chromatography to predict blood to lung, blood to liver, blood to fat and blood to skin partition coefficients of drugs.

    PubMed

    Martín-Biosca, Y; Torres-Cartas, S; Villanueva-Camañas, R M; Sagrado, S; Medina-Hernández, M J

    2009-01-26

    Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting the partition coefficients from blood to lung, blood to liver, blood to fat and blood to skin is demonstrated. PLS2 and multiple linear regression (MLR) models based on BMC retention data are proposed and compared with other ones reported in bibliography. The proposed models present better or similar descriptive and predictive capability.

  3. ORGANIC-HIGH IONIC STRENGTH AQUEOUS SOLVENT SYSTEMS FOR SPIRAL COUNTER-CURRENT CHROMATOGRAPHY: GRAPHIC OPTIMIZATION OF PARTITION COEFFICIENT.

    PubMed

    Zeng, Yun; Liu, Gang; Ma, Ying; Chen, Xiaoyuan; Ito, Yoichiro

    2013-01-10

    A new series of organic-high ionic strength aqueous two-phase solvents systems was designed for separation of highly polar compounds by spiral high-speed counter-current chromatography. A total of 21 solvent systems composed of 1-butanol-ethanol-saturated ammonium sulfate-water at various volume ratios are arranged according to an increasing order of polarity. Selection of the two-phase solvent system for a single compound or a multiple sample mixture can be achieved by two steps of partition coefficient measurements using a graphic method. The capability of the method is demonstrated by optimization of partition coefficient for seven highly polar samples including tartrazine (K=0.77), tryptophan (K=1.00), methyl green (K= 0.93), tyrosine (0.81), metanephrine (K=0.89), tyramine (K=0.98), and normetanephrine (K=0.96). Three sulfonic acid components in D&C Green No. 8 were successfully separated by HSCCC using the graphic selection of the two-phase solvent system.

  4. [Determination of partition coefficient of dissolved gases in transformer oil using phase ratio variation method and static headspace gas chromatography].

    PubMed

    Zhao, Jinghong; Wang, Hailong; Liu, Wenmin; Zhou, Yansheng; Guan, Yafeng

    2004-05-01

    The partition coefficients of dissolved gases in transformer oil were determined using a phase ratio variation method and static headspace gas chromatography (GC). A pressure balancing and gas volume-metering device was connected to the vent of a sample loop on a six-port injection valve of the GC. The gas phase sample from the headspace vial of 25 mL was transferred to an 80 microL sample-loop through a fused silica capillary of 0.53 mm i.d., and then separated and determined quantitatively by GC. A 2 m x 1 mm i.d. GDX502 micro-packed column was used for the separation. Five different gas-liquid volume ratios in the headspace vials were measured at different equilibrium concentrations. The partition coefficients of hydrocarbon gases including methane, acetylene, ethylene, ethane and propane dissolved in transformer oil were determined by using linear regression analysis at 20 degrees C and 50 degrees C separately. The errors between the real values and regression values from experimental data were less than 4.14% except methane. Fundamental data for on-line measurement of dissolved gases in transformer oil are provided by GC.

  5. Rapid analysis of dissolved methane, ethylene, acetylene and ethane using partition coefficients and headspace-gas chromatography.

    PubMed

    Lomond, Jasmine S; Tong, Anthony Z

    2011-01-01

    Analysis of dissolved methane, ethylene, acetylene, and ethane in water is crucial in evaluating anaerobic activity and investigating the sources of hydrocarbon contamination in aquatic environments. A rapid chromatographic method based on phase equilibrium between water and its headspace is developed for these analytes. The new method requires minimal sample preparation and no special apparatus except those associated with gas chromatography. Instead of Henry's Law used in similar previous studies, partition coefficients are used for the first time to calculate concentrations of dissolved hydrocarbon gases, which considerably simplifies the calculation involved. Partition coefficients are determined to be 128, 27.9, 1.28, and 96.3 at 30°C for methane, ethylene, acetylene, and ethane, respectively. It was discovered that the volume ratio of gas-to-liquid phase is critical to the accuracy of the measurements. The method performance can be readily improved by reducing the volume ratio of the two phases. Method validation shows less than 6% variation in accuracy and precision except at low levels of methane where interferences occur in ambient air. Method detection limits are determined to be in the low ng/L range for all analytes. The performance of the method is further tested using environmental samples collected from various sites in Nova Scotia.

  6. CENTRIFUGE APPARATUS

    DOEpatents

    Skarstrom, C.; Urey, H.C.; Cohen, K.

    1960-08-01

    A high-speed centrifuge for the separation of gaseous isotopes is designed comprising a centrifugal pump mounted on the outlet of a centrifuge bowl and arranged to pump the heavy and light fractions out of the centrifuge bowl in two separate streams.

  7. Partition coefficients of some environmentally important organic compounds between 1-octanol and water from reversed-phase high-performance liquid chromatography

    SciTech Connect

    Ritter, S.; Hauthal, W.H. . Inst. fuer Physikalische Chemie); Maurer, G. . Lehrstuhl fuer Technische Thermodynamik)

    1994-07-01

    1-Octanol/water partition coefficients in infinite dilution of several phenol, indole, biphenyl, and naphthalene derivatives, a few polycyclic aromatic compounds, and some polyfunctional haloaromatics determined by using reversed-phase high-performance liquid chromatography (RP-HPLC) are reported. These data may be used for estimating the ecotoxicological impact of those compounds identified in brown coal liquids (e.g., hydroxyaromatic compounds), as well as for the extension of methods to correlate and predict partition coefficients in organic/aqueous liquid phases.

  8. Chromatography.

    ERIC Educational Resources Information Center

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  9. Fractionation of protein, RNA, and plasmid DNA in centrifugal precipitation chromatography using cationic surfactant CTAB containing inorganic salts NaCl and NH(4)Cl.

    PubMed

    Tomanee, Panarat; Hsu, James T; Ito, Yoichiro

    2004-10-05

    Centrifugal precipitation chromatography (CPC) is a separation system that mainly employs a moving concentration gradient of precipitating agent along a channel and solutes of interest undergo repetitive precipitation-dissolution, fractionate at different locations, and elute out from the channel according to their solubility in the precipitating agent solution. We report here for the first time the use of a CPC system for fractionation of protein, RNA, and plasmid DNA in clarified lysate produced from bacterial culture. The cationic surfactant cetyltrimethylammonium bromide (CTAB) was initially used as a precipitating agent; however, all biomolecules showed no differential solubility in the moving concentration gradient of this surfactant and, as a result, no separation of protein, RNA, and plasmid DNA occurred. To overcome this problem, inorganic salts such as NaCl and NH(4)Cl were introduced into solution of CTAB. The protein and RNA were found to have higher solubility with the addition of these salts and separated from the plasmid DNA. Decreasing surface charge density of CTAB upon addition of NaCl and NH(4)Cl was believed to lead to lower surfactant complexation, and therefore caused differential solubility and fractionation of these biomolecules. Addition of CaCl(2) did not improve solubility and separation of RNA from plasmid DNA.

  10. Preparative fractionation of protein, RNA, and plasmid DNA using centrifugal precipitation chromatography with tubular dialysis membrane inside a convoluted tubing as separation channel.

    PubMed

    Tomanee, Panarat; Hsu, James T; Ito, Yoichiro

    2006-01-01

    Fractionation of clarified E. coli lysate components in bench-scale and preparative-scale centrifugal precipitation chromatography (CPC), using a solution of cationic surfactant cetyltrimethylammonium bromide (CTAB) containing 0.5 M NaCl as precipitant, are compared here. Step gradient of CTAB from 0.50% to 0.16% (w/v) gave a successful fractionation in bench-scale CPC; however, a linear gradient of lower CTAB concentration, 0.20-0% (w/v), was used in the preparative scale and resulted in similar fractionation. The preparative-scale CPC has a superior sample loading capacity by the use of tubular dialysis membrane inside convoluted tubing as the separation channel. In this study, the quantity of the sample loaded into the preparative CPC was about 15 times more than that in the bench scale, and in a single run the preparative CPC could prepare approximately 3 mg of plasmid DNA with about 96% of RNA removed. The higher surface area per length of the separation channel in the preparative CPC was believed to benefit mass transfer of CTAB across the membrane, leading to less CTAB being required in the process.

  11. Correlation and prediction of partition coefficient using nonrandom two-liquid segment activity coefficient model for solvent system selection in counter-current chromatography separation.

    PubMed

    Ren, Da-Bing; Yang, Zhao-Hui; Liang, Yi-Zeng; Ding, Qiong; Chen, Chen; Ouyang, Mei-Lan

    2013-08-02

    Selection of a suitable solvent system is the first and foremost step for a successful counter-current chromatography (CCC) separation. In this paper, a thermodynamic model, nonrandom two-liquid segment activity coefficient model (NRTL-SAC) which uses four types of conceptual segments to describe the effective surface interactions for each solvent and solute molecule, was employed to correlate and predict the partition coefficients (K) of a given compound in a specific solvent system. Then a suitable solvent system was selected according to the predicted partition coefficients. Three solvent system families, heptane/methanol/water, heptane/ethyl acetate/methanol/water (Arizona) and hexane/ethyl acetate/methanol/water, and several solutes were selected to investigate the effectiveness of the NRTL-SAC model for predicting the partition coefficients. Comparison between experimental results and predicted results showed that the NRTL-SAC model is of potential for estimating the K value of a given compound. Also a practical separation case on magnolol and honokiol suggests the NRTL-SAC model is effective, reliable and practical for the purpose of predicting partition coefficients and selecting a suitable solvent system for CCC separation.

  12. Separation of very hydrophobic analytes by micellar electrokinetic chromatography IV. Modeling of the effective electrophoretic mobility from carbon number equivalents and octanol-water partition coefficients.

    PubMed

    Huhn, Carolin; Pyell, Ute

    2008-07-11

    It is investigated whether those relationships derived within an optimization scheme developed previously to optimize separations in micellar electrokinetic chromatography can be used to model effective electrophoretic mobilities of analytes strongly differing in their properties (polarity and type of interaction with the pseudostationary phase). The modeling is based on two parameter sets: (i) carbon number equivalents or octanol-water partition coefficients as analyte descriptors and (ii) four coefficients describing properties of the separation electrolyte (based on retention data for a homologous series of alkyl phenyl ketones used as reference analytes). The applicability of the proposed model is validated comparing experimental and calculated effective electrophoretic mobilities. The results demonstrate that the model can effectively be used to predict effective electrophoretic mobilities of neutral analytes from the determined carbon number equivalents or from octanol-water partition coefficients provided that the solvation parameters of the analytes of interest are similar to those of the reference analytes.

  13. COSMO-RS for the prediction of the retention behavior in micellar liquid chromatography based on partition coefficients of non-dissociated and dissociated solutes.

    PubMed

    Mehling, Tanja; Kloss, Linda; Mushardt, Heike; Ingram, Thomas; Smirnova, Irina

    2013-01-18

    Several methods for the description of the retention behavior in micellar liquid chromatography (MLC) were described previously. Thereby, the most common are the linear solvation energy relationships (LSER). However, for the evaluation of the LSER, a number of experimental data are necessary. In this work, the retention data are predicted based on a single data point for a given solute/surfactant combination. The prediction of micelle/water partition coefficients with the COSMO-RS model was evaluated for the nonionic surfactant Brij 35 and the cationic CTAB for 21 solutes. The predicted partition coefficients along with the retention data of a single measurement were combined with a common retention model for the evaluation of partition coefficients. Thus, the description of the retention data based on a minimum of experimental data was realized in this work. The COSMO-RS model appears to be suitable for the flexible and qualitative prediction of the retention data, which is of special benefit, when a large number of solutes are studied. Furthermore, the introduced method is a promising alternative to describe the retention behavior of ionizable solutes, which is of great interest for e.g. pharmaceutical processes and analyses. To evaluate the method, lipophilicity profiles of several solutes were determined with MLC. While for the nonionic surfactant the lipophilicity is similar to the octanol/water system, a contrary phenomenon, namely a significant increase of the partition coefficient with progressive dissociation can be observed with the ionic surfactant. The MLC method proved to be an efficient method for the determination of micelle/water partition coefficients, excluding non-binding and "overbinding" solutes. The introduced COSMO-RS based approach for the estimation of the retention in MLC is especially promising for highly retarding solutes, since it is time and cost saving compared to the experimental determination.

  14. Centrifuge apparatus

    DOEpatents

    Sartory, Walter K.; Eveleigh, John W.

    1976-01-01

    A method and apparatus for operating a continuous flow blood separation centrifuge are provided. The hematocrit of the entrant whole blood is continuously maintained at an optimum constant value by the addition of plasma to the entrant blood. The hematocrit of the separated red cells is monitored to indicate the degree of separation taking place, thereby providing a basis for regulating the flow through the centrifuge.

  15. Different retention behavior of structurally diverse basic and neutral drugs in immobilized artificial membrane and reversed-phase high performance liquid chromatography: comparison with octanol-water partitioning.

    PubMed

    Vrakas, Demetris; Giaginis, Costas; Tsantili-Kakoulidou, Anna

    2006-05-26

    The retention behavior of 43 structurally diverse neutral and basic drugs in immobilized artificial membrane chromatography was investigated and compared to the reversed-phase retention and octanol-water partitioning. IAM chromatography was performed using morpholinepropanesulfonic acid (MOPS) or phosphate buffer saline (PBS) at pH 7.4 as the aqueous component of the mobile phase. The differences in the retention factors were attributed to increased electrostatic interactions in the MOPS environment, dependent on the fraction of charged species. Electrostatic interactions were found to play a key role in the relationships with reversed-phase retention factors determined under two different mobile phase conditions as well as in the relationships with lipophilicity data. IAM retention factors correlated better with octanol-water partition coefficients log P than with log D(7.4), as a result of the contribution of electrostatic forces in IAM retention. With log D(7.4) the relationships were improved when the fraction of charged species was taken into consideration. In any case the regression coefficient of log P or log D(7.4) was considerably lower than 1 reflecting the reduced hydrophobic environment of the IAM stationary phase. The different data sets were submitted to principal component analysis for further exploration of their similarities/dissimilarities.

  16. Chromatography

    MedlinePlus

    Chromatography is a way of separating two or more chemical compounds. Chemical compounds are chemicals that are ... of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  17. [Application of reversed-phase ion-pair chromatography for universal estimation of octanol-water partition coefficients of acid, basic and amphoteric drugs].

    PubMed

    Zhu, Hui; Yang, Ri-Fang; Yun, Liu-Hong; Jiang, Yu; Li, Jin

    2009-09-01

    This paper is to establish a reversed-phase ion-pair chromatography (RP-IPC) method for universal estimation of the octanol/water partition coefficients (logP) of a wide range of structurally diverse compounds including acidic, basic, neutral and amphoteric species. The retention factors corresponding to 100% water (logk(w)) were derived from the linear part of the logk'/phi relationship, using at least four isocratic logk' values containing different organic compositions. The logk(w) parameters obtained were close to the corresponding logP values obtained with the standard "shake flask" methods. The mean deviation for test drugs is 0.31. RP-IPC with trifluoroacetic acid as non classic ion-pair agents can be applicable to determine the logP values for a variety of drug-like molecules with increased accuracy.

  18. Determination of solute partition behavior with room-temperature ionic liquid based micellar gas-liquid chromatography stationary phases using the pseudophase model.

    PubMed

    Lantz, Andrew W; Pino, Verónica; Anderson, Jared L; Armstrong, Daniel W

    2006-05-19

    The use of micelles in ionic liquid based gas-chromatography stationary phases was evaluated using equations derived for a "three-phase" model. This model allows the determination of all three partition coefficients involved in the system, and elucidates the micellar contribution to retention and selectivity. Four types of micellar-ionic liquid columns were examined in this study: 1-butyl-3-methylimidazolium chloride with sodium dodecylsulfate or dioctyl sulfosuccinate, and 1-butyl-3-methylimidazolium hexafluorophosphate with polyoxyethylene-100-stearyl ether or polyoxyethylene-23-lauryl ether. The partition coefficients were measured for a wide range of probe molecules capable of a variety of types and magnitudes of interactions. In general, most probe molecules preferentially partitioned to the micellar pseudophase over the bulk ionic liquid component of the stationary phase. Therefore, addition of surfactant to the stationary phase usually resulted in greater solute retention. It is also shown that the selectivity of the stationary phase is significantly altered by the presence of micelles, either by enhancing or lessening the separation. The effects of surfactant on the interaction parameters of the stationary phase are determined using the Abraham solvation parameter model. The addition of sodium dodecylsulfate and dioctyl sulfosuccinate to 1-butyl-3-methylimidazolium chloride stationary phases generally increased the phase's hydrogen bond basicity and increased the level of dispersion interaction. Polyoxyethylene-100-stearyl ether and polyoxyethylene-23-lauryl ether surfactants, however, enhanced the pi-pi/n-pi, polarizability/dipolarity, and hydrogen bond basicity interactions of 1-butyl-3-methylimidazolium hexafluorophosphate to a greater degree than the ionic surfactants with 1-butyl-3-methylimidazolium chloride. However, these nonionic surfactants appeared to hinder the ability of the stationary phase to interact with solutes via dispersion forces

  19. Analysis of selected designer benzodiazepines by UHPLC with high-resolution time-of-flight mass spectrometry and the estimation of their partition coefficients by micellar electrokinetic chromatography.

    PubMed

    Tomková, Jana; Švidrnoch, Martin; Maier, Vítězslav; Ondra, Peter

    2017-03-07

    A new ultra high performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry method for the selective and sensitive separation, identification and determination of selected designer benzodiazepines (namely, pyrazolam, phenazepam, etizolam, flubromazepam, diclazepam, deschloroetizolam, bentazepam, nimetazepam and flubromazolam) in human serum was developed. The separation of the studied designer benzodiazepines was achieved on C18 chromatographic column using gradient elution within 6 min without any significant matrix interferences. Liquid-liquid extraction with butyl acetate was applied for serum samples clean-up and preconcentration of studied designer benzodiazepines. The method was validated in terms of linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery and sample stability. The limit of detection values were in range 0.10-0.15 ng/mL. The method was applied on spiked serum sample to demonstrate its applicability for systematic toxicology analysis. Furthermore, a capillary chromatographic method with micellar electrokinetic chromatography was used for the estimation of partition coefficients of studied designer benzodiazepines as important parameters to evaluate their pharmacological and toxicological properties. This article is protected by copyright. All rights reserved.

  20. Neuere Chromatographie

    NASA Astrophysics Data System (ADS)

    Hostettmann, K.

    1983-04-01

    Besides high-performance liquid chromatography (HPLC) which is now a well-established and currently used technique, several emerging methods for the isolation and separation of natural products are receiving considerable attention. Centrifugal thin-layer chromatography is a very rapid technique, but limited in resolution. Of special interest are the recently developed support-free liquid-liquid chromatography methods such as droplet counter-current chromatography (DCCC) and rotation locular counter-current chromatography (RLCC). This latter method was applied to the separation of the enantiomers of (±)-norephedrine.

  1. [Determination of six main components in compound theophylline tablet by convolution curve method after prior separation by column partition chromatography

    NASA Technical Reports Server (NTRS)

    Zhang, S. Y.; Wang, G. F.; Wu, Y. T.; Baldwin, K. M. (Principal Investigator)

    1993-01-01

    On a partition chromatographic column in which the support is Kieselguhr and the stationary phase is sulfuric acid solution (2 mol/L), three components of compound theophylline tablet were simultaneously eluted by chloroform and three other components were simultaneously eluted by ammonia-saturated chloroform. The two mixtures were determined by computer-aided convolution curve method separately. The corresponding average recovery and relative standard deviation of the six components were as follows: 101.6, 1.46% for caffeine; 99.7, 0.10% for phenacetin; 100.9, 1.31% for phenobarbitone; 100.2, 0.81% for theophylline; 99.9, 0.81% for theobromine and 100.8, 0.48% for aminopyrine.

  2. Centrifugal pyrocontactor

    DOEpatents

    Chow, L.S.; Leonard, R.A.

    1993-10-19

    A method is described for mixing and separating immiscible liquid salts and liquid metals in a centrifugal contractor. The method includes introducing the liquids into an annular mixing zone and intensely mixing the liquids using vertical vanes attached to a rotor cooperating with vertical baffles, a horizontal baffle, and bottom vanes attached to the contactor housing. The liquids enter the contactor in the range of 700-800 degrees Celsius. The liquids are separated in the rotor into a dense phase and a light phase which are discharged from the contactor. 6 figures.

  3. Centrifugal pyrocontactor

    DOEpatents

    Chow, Lorac S.; Leonard, Ralph A.

    1993-01-01

    A method for mixing and separating immiscible liquid salts and liquid metals in a centrifugal contractor. The method includes introducing the liquids into an annular mixing zone and intensely mixing the liquids using vertical vanes attached to a rotor cooperating with vertical baffles, a horizontal baffle, and bottom vanes attached to the contactor housing. The liquids enter the contactor in the range of 700-800 degrees Celsius. The liquids are separated in the rotor into a dense phase and a light phase which are discharged from the contactor.

  4. Determination of the n-octanol/water partition coefficients of weakly ionizable basic compounds by reversed-phase high-performance liquid chromatography with neutral model compounds.

    PubMed

    Liang, Chao; Han, Shu-ying; Qiao, Jun-qin; Lian, Hong-zhen; Ge, Xin

    2014-11-01

    A strategy to utilize neutral model compounds for lipophilicity measurement of ionizable basic compounds by reversed-phase high-performance liquid chromatography is proposed in this paper. The applicability of the novel protocol was justified by theoretical derivation. Meanwhile, the linear relationships between logarithm of apparent n-octanol/water partition coefficients (logKow '') and logarithm of retention factors corresponding to the 100% aqueous fraction of mobile phase (logkw ) were established for a basic training set, a neutral training set and a mixed training set of these two. As proved in theory, the good linearity and external validation results indicated that the logKow ''-logkw relationships obtained from a neutral model training set were always reliable regardless of mobile phase pH. Afterwards, the above relationships were adopted to determine the logKow of harmaline, a weakly dissociable alkaloid. As far as we know, this is the first report on experimental logKow data for harmaline (logKow = 2.28 ± 0.08). Introducing neutral compounds into a basic model training set or using neutral model compounds alone is recommended to measure the lipophilicity of weakly ionizable basic compounds especially those with high hydrophobicity for the advantages of more suitable model compound choices and convenient mobile phase pH control.

  5. Linear modeling of the soil-water partition coefficient normalized to organic carbon content by reversed-phase thin-layer chromatography.

    PubMed

    Andrić, Filip; Šegan, Sandra; Dramićanin, Aleksandra; Majstorović, Helena; Milojković-Opsenica, Dušanka

    2016-08-05

    Soil-water partition coefficient normalized to the organic carbon content (KOC) is one of the crucial properties influencing the fate of organic compounds in the environment. Chromatographic methods are well established alternative for direct sorption techniques used for KOC determination. The present work proposes reversed-phase thin-layer chromatography (RP-TLC) as a simpler, yet equally accurate method as officially recommended HPLC technique. Several TLC systems were studied including octadecyl-(RP18) and cyano-(CN) modified silica layers in combination with methanol-water and acetonitrile-water mixtures as mobile phases. In total 50 compounds of different molecular shape, size, and various ability to establish specific interactions were selected (phenols, beznodiazepines, triazine herbicides, and polyaromatic hydrocarbons). Calibration set of 29 compounds with known logKOC values determined by sorption experiments was used to build simple univariate calibrations, Principal Component Regression (PCR) and Partial Least Squares (PLS) models between logKOC and TLC retention parameters. Models exhibit good statistical performance, indicating that CN-layers contribute better to logKOC modeling than RP18-silica. The most promising TLC methods, officially recommended HPLC method, and four in silico estimation approaches have been compared by non-parametric Sum of Ranking Differences approach (SRD). The best estimations of logKOC values were achieved by simple univariate calibration of TLC retention data involving CN-silica layers and moderate content of methanol (40-50%v/v). They were ranked far well compared to the officially recommended HPLC method which was ranked in the middle. The worst estimates have been obtained from in silico computations based on octanol-water partition coefficient. Linear Solvation Energy Relationship study revealed that increased polarity of CN-layers over RP18 in combination with methanol-water mixtures is the key to better modeling of

  6. Development of a mitochondria-based centrifugal ultrafiltration/liquid chromatography/mass spectrometry method for screening mitochondria-targeted bioactive constituents from complex matrixes: Herbal medicines as a case study.

    PubMed

    Yang, Xing-Xin; Xu, Feng; Wang, Dan; Yang, Zhi-Wei; Tan, Huan-Ran; Shang, Ming-Ying; Wang, Xuan; Cai, Shao-Qing

    2015-09-25

    Mitochondria are an important intracellular pharmacological target because damage to this organelle results in a variety of human disorders and because mitochondria are involved in complex processes such as energy generation, apoptosis and lipid metabolism. To expedite the search for natural bioactive compounds targeting mitochondria, we initially developed an efficient mitochondria-based screening method by combining centrifugal ultrafiltration (CU) with liquid chromatography/mass spectrometry (LC/MS), which is called screening method for mitochondria-targeted bioactive constituents (SM-MBC) and is compatible with the search of mitochondria-targeted compounds from complex matrixes such as herbal medicines extracts. Functionally active, structurally intact and pure mitochondria were obtained from rat myocardium using an optimized protocol for mitochondrial isolation comprising organelle release followed by differential and Nycodenz density gradient centrifugation. After evaluating the reliability of the method using thiabendazole (TZ), rotenone (RN), amiodarone (AR) and trimetazidine (TD) as positive controls, this method was successfully applied to screen bioactive constituents from extracts of Polygoni Cuspidati Rhizoma et Radix (PCRR) and Scutellariae Radix (SR). Nineteen active compounds were detected and identified by LC/MS, of which 17 were new mitochondria-targeted compounds. The activity of 9 of the 19 hit compounds was confirmed by in vitro pharmacological trials. These results demonstrate that SM-MBC can be used for the efficient screening of mitochondria-targeted constituents in complex preparations used to treat mitochondrial disorders, such as PCRR and SR. The results may be meaningful for an in-depth understanding of drug mechanism of action and drug discovery from medicinal herbs.

  7. CENTRIFUGE END CAP

    DOEpatents

    Beams, J.W.; Snoddy, L.B.

    1960-08-01

    An end cap for ultra-gas centrifuges is designed to impart or remove angular momentum to or from the gas and to bring the entering gas to the temperature of the gas inside the centrifuge. The end cap is provided with slots or fins for adjusting the temperature and the angular momentum of the entering gas to the temperature and momentum of the gas in the centrifuge and is constructed to introduce both the inner and the peripheral stream into the centrifuge.

  8. Partition search

    SciTech Connect

    Ginsberg, M.L.

    1996-12-31

    We introduce a new form of game search called partition search that incorporates dependency analysis, allowing substantial reductions in the portion of the tree that needs to be expanded. Both theoretical results and experimental data are presented. For the game of bridge, partition search provides approximately as much of an improvement over existing methods as {alpha}-{beta} pruning provides over minimax.

  9. METHOD OF CENTRIFUGE OPERATION

    DOEpatents

    Cohen, K.

    1960-05-10

    A method of isotope separation is described in which two streams are flowed axially of, and countercurrently through, a cylindrical centrifuge bowl. Under the influence of a centrifugal field, the light fraction is concentrated in a stream flowing through the central portion of the bowl, whereas the heavy fraction is concentrated in a stream at the periphery thereof.

  10. Valve for gas centrifuges

    DOEpatents

    Hahs, C.A.; Rurbage, C.H.

    1982-03-17

    The invention is pneumatically operated valve assembly for simulatenously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two on the lines so closed. The value assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  11. A novel method for the determination of adsorption partition coefficients of minor gases in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2013-10-04

    A novel method has been developed for the determination of adsorption partition coefficient (Kd) of minor gases in shale. The method uses samples of two different sizes (masses) of the same material, from which the partition coefficient of the gas can be determined from two independent headspace gas chromatographic (HS-GC) measurements. The equilibrium for the model gas (ethane) was achieved in 5h at 120°C. The method also involves establishing an equation based on the Kd at higher equilibrium temperature, from which the Kd at lower temperature can be calculated. Although the HS-GC method requires some time and effort, it is simpler and quicker than the isothermal adsorption method that is in widespread use today. As a result, the method is simple and practical and can be a valuable tool for shale gas-related research and applications.

  12. The Generally Useful Estimate of Solvent Systems (GUESS) method enables the rapid purification of methylpyridoxine regioisomers by countercurrent chromatography

    PubMed Central

    Liu, Yang; Friesen, J. Brent; Klein, Larry L.; McAlpine, James B.; Lankin, David C.; Pauli, Guido F.; Chen, Shao-Nong

    2016-01-01

    The TLC-based Generally Useful Estimate of Solvent Systems (GUESS) method was employed for countercurrent chromatography solvent system selection, in order to separate the three synthetic isomers: 3-O-methylpyridoxine, 4′-O-methylpyridoxine (ginkgotoxin) and 5′-O-methylpyridoxine. The Rf values of the three isomers indicated that ChMWat +2 (chloroformmethanol-water 10:5:5, v/v/v) was appropriate for the countercurrent chromatography. The isomer separation was highly selective and demonstrated that the TLC-based GUESS method can accelerate solvent system selection for countercurrent chromatography. Accordingly, the study re-emphasizes the practicality of TLC as a tool to facilitate the rapid development of new countercurrent and centrifugal partition chromatography methods for this solvent system. Purity and structure characterization of all samples was performed by quantitative 1H NMR. PMID:26680272

  13. Determination of polydimethylsiloxane–water partition coefficients for ten 1-chloro-4-[2,2,2-trichloro-1-(4-chlorophenyl)ethyl]benzene-related compounds and twelve polychlorinated biphenyls using gas chromatography/mass spectrometry

    USGS Publications Warehouse

    Eganhouse, Robert P.

    2016-01-01

    Polymer-water partition coefficients (Kpw) of ten DDT-related compounds were determined in pure water at 25 °C using commercial polydimethylsiloxane-coated optical fiber. Analyte concentrations were measured by thermal desorption-gas chromatography/full scan mass spectrometry (TD–GC/MSFS; fibers) and liquid injection-gas chromatography/selected ion monitoring mass spectrometry (LI–GC/MSSIM; water). Equilibrium was approached from two directions (fiber uptake and depletion) as a means of assessing data concordance. Measured compound-specific log Kpw values ranged from 4.8 to 6.1 with an average difference in log Kpw between the two approaches of 0.05 log units (∼12% of Kpw). Comparison of the experimentally-determined log Kpw values with previously published data confirmed the consistency of the results and the reliability of the method. A second experiment was conducted with the same ten DDT-related compounds and twelve selected PCB (polychlorinated biphenyl) congeners under conditions characteristic of a coastal marine field site (viz., seawater, 11 °C) that is currently under investigation for DDT and PCB contamination. Equilibration at lower temperature and higher ionic strength resulted in an increase in log Kpw for the DDT-related compounds of 0.28–0.49 log units (61–101% of Kpw), depending on the analyte. The increase in Kpw would have the effect of reducing by approximately half the calculated freely dissolved pore-water concentrations (Cfree). This demonstrates the importance of determining partition coefficients under conditions as they exist in the field.

  14. Chromatographic retention prediction and octanol-water partition coefficient determination of monobasic weak acidic compounds in ion-suppression reversed-phase liquid chromatography using acids as ion-suppressors.

    PubMed

    Ming, Xin; Han, Shu-ying; Qi, Zheng-chun; Sheng, Dong; Lian, Hong-zhen

    2009-08-15

    Although simple acids, replacing buffers, have been widely applied to suppress the ionization of weakly ionizable acidic analytes in reversed-phase liquid chromatography (RPLC), none of the previously reported works focused on the systematic studies about the retention behavior of the acidic solutes in this ion-suppression RPLC mode. The subject of this paper was therefore to investigate the retention behavior of monobasic weak acidic compounds using acetic, perchloric and phosphoric acids as the ion-suppressors. The apparent octanol-water partition coefficient (K" ow) was proposed to calibrate the octanol-water partition coefficient (K(ow)) of these weak acidic compounds, which resulted in a better linear correlation with log k(w), the logarithm of the hypothetical retention factor corresponding to neat aqueous fraction of hydroorganic mobile phase. This log K" ow-log k w linear correlation was successfully validated by the results of monocarboxylic acids and monohydrating phenols, and moreover by the results under diverse experimental conditions for the same solutes. This straightforward relationship not only can be used to effectively predict the retention values of weak acidic solutes combined with Snyder-Soczewinski equation, but also can offer a promising medium for directly measuring K(ow) data of these compounds via Collander equation. In addition, the influence of the different ion-suppressors on the retention of weak acidic compounds was also compared in this RPLC mode.

  15. Partition Equilibrium

    NASA Astrophysics Data System (ADS)

    Feldman, Michal; Tennenholtz, Moshe

    We introduce partition equilibrium and study its existence in resource selection games (RSG). In partition equilibrium the agents are partitioned into coalitions, and only deviations by the prescribed coalitions are considered. This is in difference to the classical concept of strong equilibrium according to which any subset of the agents may deviate. In resource selection games, each agent selects a resource from a set of resources, and its payoff is an increasing (or non-decreasing) function of the number of agents selecting its resource. While it has been shown that strong equilibrium exists in resource selection games, these games do not possess super-strong equilibrium, in which a fruitful deviation benefits at least one deviator without hurting any other deviator, even in the case of two identical resources with increasing cost functions. Similarly, strong equilibrium does not exist for that restricted two identical resources setting when the game is played repeatedly. We prove that for any given partition there exists a super-strong equilibrium for resource selection games of identical resources with increasing cost functions; we also show similar existence results for a variety of other classes of resource selection games. For the case of repeated games we identify partitions that guarantee the existence of strong equilibrium. Together, our work introduces a natural concept, which turns out to lead to positive and applicable results in one of the basic domains studied in the literature.

  16. Valve for gas centrifuges

    DOEpatents

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  17. DETERMINATION OF IN VITRO AND IN SILICO INDEXES FOR THE MODELLING OF BLOOD-BRAIN BARRIER PARTITIONING OF DRUGS VIA MICELLAR AND IMMOBILIZED ARTIFICIAL MEMBRANE LIQUID CHROMATOGRAPHY.

    PubMed

    Russo, Giacomo; Grumetto, Lucia; Szucs, Roman; Barbato, Francesco; Lynen, Frederic

    2017-04-11

    In the present work, 79 structurally unrelated analytes were taken into account and their chromatographic retention coefficients, measured by Immobilized Artificial Membrane Liquid Chromatography (IAM-LC), and by Micellar Liquid Chromatography (MLC) employing sodium dodecyl sulfate (SDS) as surfactant, were determined. Such indexes were subsequently used for the development of Blood-Brain Barrier passage-predictive statistical models using partial least square (PLS) regression along with topological and physico-chemical parameters, calculated in silico. Highly significant relationships were observed either using IAM (r2 (n-1) = 0.78) or MLC (r2 (n-1) = 0.83) derived indexes along with in silico descriptors. This hybrid approach proved fast and effective in the development of highly predictive BBB passage oriented models and, therefore, it can be of interest for pharmaceutical industries as a high-throughput BBB penetration oriented screening method. Finally, it offered interesting insights into the molecular mechanism actually involved in the BBB permeation of drugs.

  18. Centrifugal main fuel pump

    SciTech Connect

    Cole, E.F.

    1986-08-26

    For a gas turbine power plant having a fuel supply and a fuel metering valve and variable geometry for the power plant including servo actuating mechanisms for the fuel metering valve and variable geometry, a fuel pumping system, is described to supply pressurized fuel for the servo actuating mechanisms and for the engine working fluid medium. The pumping system includes a centrifugal pump solely supplying the fuel to the fuel metering valve to be delivered to the power plant for its working fluid medium, a positive displacement pump in parallel with the centrifugal pump and solely to supply pressurized fuel to the servo actuating mechanisms for the fuel metering valve and for the variable geometry, and a boost pump means disposed in serial relationship with the positive displacement pump and the centrifugal pump for augmenting the pressure supplied by the positive displacement pump and the centrifugal pump during predetermined operating conditions of the power plant. The combined boost pump and centrifugal pump capability is sufficient to satisfy the vapor to liquid ratio requirements of the power during its entire operating envelope.

  19. SEAL FOR HIGH SPEED CENTRIFUGE

    DOEpatents

    Skarstrom, C.W.

    1957-12-17

    A seal is described for a high speed centrifuge wherein the centrifugal force of rotation acts on the gasket to form a tight seal. The cylindrical rotating bowl of the centrifuge contains a closure member resting on a shoulder in the bowl wall having a lower surface containing bands of gasket material, parallel and adjacent to the cylinder wall. As the centrifuge speed increases, centrifugal force acts on the bands of gasket material forcing them in to a sealing contact against the cylinder wall. This arrangememt forms a simple and effective seal for high speed centrifuges, replacing more costly methods such as welding a closure in place.

  20. Geotechnical centrifuge under construction

    NASA Astrophysics Data System (ADS)

    Richman, Barbara T.

    Modifications are underway at the National Aeronautics and Space Administration (NASA) Ames Research Center in California to transform a centrifuge used in the Apollo space program to the largest geotechnical centrifuge in the free world. The centrifuge, to be finished in August and opened next January, following check out and tuning, will enable geoscientists to model stratigraphic features down to 275 m below the earth's surface. Scientists will be able to model processes that are coupled with body force loading, including earthquake response of earth structures and soil structure interaction; rubbled-bed behavior during in situ coal gasification or in oil shale in situ retorts; behavior of frozen soil; frost heave; behavior of offshore structures; wave-seabed interactions; explosive cratering; and blast-induced liquefaction.The centrifuge will have a load capacity of 900-g-tons (short); that is, it will be able to carry a net soil load of 3 short tons to a centripetal acceleration of 300 times the acceleration caused by gravity. Modified for a total cost of $2.4 million, the centrifuge will have an arm with a 7.6-m radius and a swinging platform or bucket at its end that will be able to carry a payload container measuring 2.1×2.1 m. An additional future input of $500,000 would enable the purchase of a larger bucket that could accommodate a load of up to 20 tons, according to Charles Babendreier, program director for geotechnical engineering at the National Science Foundation. Additional cooling for the motor would also be required. The centrifuge has the capability of accelerating the 20-ton load to 100 g.

  1. Simultaneous determination of organotin compounds in textiles by gas chromatography-flame photometry following liquid/liquid partitioning with tert-butyl ethyl ether after reflux-extraction.

    PubMed

    Hamasaki, Tetsuo

    2013-10-15

    A rapid and relatively clean method for determining six organotin compounds (OtC) in textile goods with a gas chromatograph equipped with a conventional flame photometric detector (GC-FPD) has been developed. After the reflux-extraction to use methanol containing 1% (v/v) of hydrochloric acid, five hydrophobic OtC (e.g. tributyltin: TBT) and slightly less hydrophobic dibutyltin (DBT) could be drawn out through partitioning between the methanolic buffer solution and tert-butyl ethyl ether instead of hazardous dichloromethane, of which usage is provided by the official-methods notified in Japan, and following the ethylation procedure to use sodium tetraethylborate, the OtC were determined with the GC-FPD. The recoveries of DBT, TBT, tetrabutyltin, triphenyltin, dioctyltin, and trioctyltin from textile products (cloth diaper, socks, and undershirt) were 60-77, 89-98, 86-94, 71-78, 85-109, and 70-79% respectively, and their coefficients of variation were 2.5-16.5%. Calibration curves for OtC were linear (0.01-0.20 μg as Sn mL(-1)), and the correlation coefficients were 0.9922-1.0000. Their detection limits were estimated to be 2.7-9.7 n gas Sn g(-1). These data suggested that this method would be applicable to their simultaneous determination. Five retailed textile goods were analyzed by this proposed method, and 0.013-0.65 µg as Sn g(-1) of OtC (e.g. DBT) were determined in three. Moreover, a possibility that various OtC including non-targeted species in textile would be specifically detected by applying the studying speciation-technique of controlling signal intensity-flame fuel gas pressures of the GC-FPD was found.

  2. Human Powered Centrifuge

    NASA Technical Reports Server (NTRS)

    Mulenburg, Gerald M. (Inventor); Vernikos, Joan (Inventor)

    1997-01-01

    A human powered centrifuge has independently established turntable angular velocity and human power input. A control system allows excess input power to be stored as electric energy in a battery or dissipated as heat through a resistors. In a mechanical embodiment, the excess power is dissipated in a friction brake.

  3. A new non-synchronous preparative counter-current centrifuge-the next generation of dynamic extraction/chromatography devices with independent mixing and settling control, which offer a step change in efficiency.

    PubMed

    Ignatova, Svetlana; Hawes, David; van den Heuvel, Remco; Hewitson, Peter; Sutherland, Ian A

    2010-01-01

    A new and significantly more robust design of non-synchronous coil planet centrifuge is introduced where the degree of mixing between two immiscible phases can be changed independently from the "g" field required to separate out the phases. A hypothesis that an optimum ratio between the speed of the bobbin and the speed of the rotor can be found to optimise the efficiency of the separation for a given force field is upheld for an intermediate polarity phase system. This paves the way for extensive further research to find the optimum non-synchronous conditions for a range of different phase systems that are desirable for the separation of large molecules, proteins and biologics but can tend to emulsify in the standard "J" type centrifuge systems currently available and routinely in use for aqueous organic phase systems. A step change of up to 30% in resolution and 90% in plate efficiency is demonstrated.

  4. Enhancing Centrifugal Separation With Electrophoresis

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1986-01-01

    Separation of biological cells by coil-planet centrifuge enhanced by electrophoresis. By itself, coil-planet centrifuge offers relatively gentle method of separating cells under low centrifugal force in physiological medium that keeps cells alive. With addition of voltage gradient to separation column of centrifuge, separation still gentle but faster and more complete. Since separation apparatus contains no rotary seal, probability of leakage, contamination, corrosion, and short circuits reduced.

  5. In vitro prediction of human intestinal absorption and blood-brain barrier partitioning: development of a lipid analog for micellar liquid chromatography.

    PubMed

    De Vrieze, Mike; Janssens, Pieter; Szucs, Roman; Van der Eycken, Johan; Lynen, Frédéric

    2015-09-01

    Over the past decades, several in vitro methods have been tested for their ability to predict either human intestinal absorption (HIA) or penetration across the blood-brain barrier (BBB) of drugs. Micellar liquid chromatography (MLC) has been a successful approach for retention time measurements of drugs to establish models together with other molecular descriptors. Thus far, MLC approaches have only made use of commercial surfactants such as sodium dodecyl sulfate (SDS) and polyoxyethylene (23) lauryl ether (Brij35), which are not representative for the phospholipids present in human membranes. Miltefosine, a phosphocholine-based lipid, is presented here as an alternative surfactant for MLC measurements. By using the obtained retention factors and several computed descriptors for a set of 48 compounds, two models were constructed: one for the prediction of HIA and another for the prediction of penetration across the BBB expressed as log BB. All data were correlated to experimental HIA and log BB values, and the performance of the models was evaluated. Log BB prediction performed better than HIA prediction, although HIA prediction was also improved a lot (from 0.5530 to 0.7175) compared to in silico predicted HIA values.

  6. The Human Centrifuge

    NASA Astrophysics Data System (ADS)

    van Loon, Jack J. W. A.

    2009-01-01

    Life on Earth has developed at unit gravity, 9.81 m/s2, which was a major factor especially when vertebrates emerged from water onto land in the late Devonian, some 375 million years ago. But how would nature have evolved on a larger planet? We are able to address this question simply in experiments using centrifuges. Based on these studies we have gained valuable insights in the physiological process in plants and animals. They adapt to a new steady state suitable for the high-g environments applied. Information on mammalian adaptations to hyper-g is interesting or may be even vital for human space exploration programs. It has been shown in long duration animal hypergravity studies, ranging from snails, rats to primates, that various structures like muscles, bones, neuro-vestibular, or the cardio-vascular system are affected. However, humans have never been exposed to a hyper-g environment for long durations. Centrifuge studies involving humans are mostly in the order of hours. The current work on human centrifuges are all focused on short arm systems to apply short periods of artificial gravity in support of long duration space missions in ISS or to Mars. In this paper we will address the possible usefulness of a large human centrifuge on Earth. In such a centrifuge a group of humans can be exposed to hypergravity for, in principle, an unlimited period of time like living on a larger planet. The input from a survey under scientists working in the field of gravitational physiology, but also other disciplines, will be discussed.

  7. Centrifugally decoupling touchdown bearings

    DOEpatents

    Post, Richard F

    2014-06-24

    Centrifugally decoupling mechanical bearing systems provide thin tensioned metallic ribbons contained in a support structure. This assembly rotates around a stationary shaft being centered at low speeds by the action of the metal ribbons. Tension springs are connected on one end to the ribbons and on the other end to the support structure. The ribbons pass through slots in the inner ring of the support structure. The spring preloading thus insures contact (or near-contact) between the ribbons and the shaft at rotation speeds below the transition speed. Above this speed, however, the centrifugal force on the ribbons produces a tensile force on them that exceeds the spring tensile force so that the ribbons curve outward, effectively decoupling them from mechanical contact with the shaft. They still remain, however, in position to act as a touchdown bearing in case of abnormally high transverse accelerations.

  8. Centrifugal pump fuel system

    SciTech Connect

    McGlone, M.E.; Larkins, L.J.; Johnson, R.O.; Moeller, K.A.

    1993-06-22

    A centrifugal pump fuel system for an engine driven fuel pump for an aircraft gas turbine engine is described comprising: a centrifugal pump having at constant speed rising head/flow characteristic at low flows; a plumbing system receiving flow from the pump, and having at least one control valve located down stream of and defining a discrete volume of the plumbing system; a plumbing resonant frequency defined by the discrete volume, the geometry of the plumbing system, and the bulk modulus of the fuel; a pressure difference regulating valve located adjacent to the discharge of the pump, up stream of the vast majority of the discrete volume; and the frequency response of the regulating valve being significantly less than the frequency response of the plumbing system such that the response of the regulating valve is attenuated at the resonant frequency of the plumbing system.

  9. Centrifugal unbalance detection system

    DOEpatents

    Cordaro, Joseph V.; Reeves, George; Mets, Michael

    2002-01-01

    A system consisting of an accelerometer sensor attached to a centrifuge enclosure for sensing vibrations and outputting a signal in the form of a sine wave with an amplitude and frequency that is passed through a pre-amp to convert it to a voltage signal, a low pass filter for removing extraneous noise, an A/D converter and a processor and algorithm for operating on the signal, whereby the algorithm interprets the amplitude and frequency associated with the signal and once an amplitude threshold has been exceeded the algorithm begins to count cycles during a predetermined time period and if a given number of complete cycles exceeds the frequency threshold during the predetermined time period, the system shuts down the centrifuge.

  10. Centrifugal adsorption system

    NASA Technical Reports Server (NTRS)

    Gonda, Steve R. (Inventor); Tsao, Yow-Min D. (Inventor); Lee, Wenshan (Inventor)

    2006-01-01

    A gas-liquid separator uses a helical passageway to impart a spiral motion to a fluid passing therethrough. The centrifugal force generated by the spiraling motion urges the liquid component of the fluid radially outward which forces the gas component radially inward. The gas component is then separated through a gas-permeable, liquid-impervious membrane and discharged through a central passageway. A filter material captures target substances contained in the fluid.

  11. Oscillatory counter-centrifugation

    NASA Astrophysics Data System (ADS)

    Xu, Shujing; Nadim, Ali

    2016-02-01

    In ordinary centrifugation, a suspended particle that is heavier than the displaced fluid migrates away from the rotation axis when the fluid-filled container rotates steadily about that axis. In contrast a particle that is lighter than the displaced fluid (e.g., a bubble) migrates toward the rotation axis in a centrifuge. In this paper, we show theoretically that if a fluid-filled container rotates in an oscillatory manner as a rigid body about an axis, at high enough oscillation frequencies, the sense of migration of suspended particles is reversed. That is, in that case particles denser than the fluid migrate inward, while those that are lighter than the fluid move outward. We term this unusual phenomenon "Oscillatory Counter-Centrifugation" or OCC, for short. Through application of the method of averaging to the equations of motion, we derive a simple criterion to predict the occurrence of OCC. The analysis also reveals that the time-average of the Coriolis force in the radial direction is the term that is responsible for this effect. In addition, we analyze the effects of the Basset history force and the Rubinow-Keller lift force on particle trajectories and find that OCC persists even when these forces are active. The phenomenon awaits experimental verification.

  12. Separation techniques: Chromatography

    PubMed Central

    Coskun, Ozlem

    2016-01-01

    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture for qualitative and quantitative analysis. Proteins can be purified based on characteristics such as size and shape, total charge, hydrophobic groups present on the surface, and binding capacity with the stationary phase. Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the most common methods of protein purification. PMID:28058406

  13. Gas Centrifuges and Nuclear Proliferation

    SciTech Connect

    Albright, David

    2004-09-15

    Gas centrifuges have been an ideal enrichment method for a wide variety of countries. Many countries have built gas centrifuges to make enriched uranium for peaceful nuclear purposes. Other countries have secretly sought centrifuges to make highly enriched uranium for nuclear weapons. In more recent times, several countries have secretly sought or built gas centrifuges in regions of tension. The main countries that have been of interest in the last two decades have been Pakistan, Iraq, Iran, and North Korea. Currently, most attention is focused on Iran, Pakistan, and North Korea. These states did not have the indigenous abilities to make gas centrifuges, focusing instead on illicit and questionable foreign procurement. The presentation covered the following main sections: Spread of centrifuges through illicit procurement; Role of export controls in stopping proliferation; Increasing the transparency of gas centrifuge programs in non-nuclear weapon states; and, Verified dismantlement of gas centrifuge programs. Gas centrifuges are important providers of low enriched uranium for civil nuclear power reactors. They also pose special nuclear proliferation risks. We all have special responsibilities to prevent the spread of gas centrifuges into regions of tension and to mitigate the consequences of their spread into the Middle East, South Asia, and North Asia.

  14. A simplified purification method for AAV variant by polyethylene glycol aqueous two-phase partitioning.

    PubMed

    Guo, Ping; Xiao, Xiangwei; El-Gohary, Yousef; Paredes, Jose; Prasadan, Krishna; Shiota, Chiyo; Wiersch, John; Welsh, Carey; Gittes, George K

    2013-01-01

    Adeno-Associated Virus (AAV) has been widely used for in vivo study and preclinical therapy due to its ability to mediate long-term transgene expression, its lack of pathogenicity and low immunogenicity. It has been found that AAV has more than ten serotypes, which each transfect certain types of cells in the viral infected organ. Current methods for purification of different AAV serotypes utilize CsCl or Iodixanol ultrahigh speed density gradient centrifugation, which is expensive and time consuming. We recently developed a simplified method, PEG/(NH(4))(2)SO(4) aqueous two phase partitioning, for purification of AAV serotype 2 and 8. The method does not require ultrahigh speed gradient centrifugation or chromatography. Here we further explore the simplified method for purification of other serotypes of AAV, serotype 6 and 9. This simplified method not only can be used to purify serotype 2 and 8, but also serotype 6 and 9, indicating that a variety of AAV serotypes can be purified by this method.

  15. CENTRIFUGAL MEMBRANE FILTRATION

    SciTech Connect

    Daniel J. Stepan; Bradley G. Stevens; Melanie D. Hetland

    1999-10-01

    The overall project consists of several integrated research phases related to the applicability, continued development, demonstration, and commercialization of the SpinTek centrifugal membrane filtration process. Work performed during this reporting period consisted of Phase 2 evaluation of the SpinTek centrifugal membrane filtration technology and Phase 3, Technology Partnering. During Phase 1 testing conducted at the EERC using the SpinTek ST-IIL unit operating on a surrogate tank waste, a solids cake developed on the membrane surface. The solids cake was observed where linear membrane velocities were less than 17.5 ft/s and reduced the unobstructed membrane surface area up to 25%, reducing overall filtration performance. The primary goal of the Phase 2 research effort was to enhance filtration performance through the development and testing of alternative turbulence promoter designs. The turbulence promoters were designed to generate a shear force across the entire membrane surface sufficient to maintain a self-cleaning membrane capability and improve filtration efficiency and long-term performance. Specific Phase 2 research activities included the following: System modifications to accommodate an 11-in.-diameter, two-disk rotating membrane assembly; Development and fabrication of alternative turbulence promoter designs; Testing and evaluation of the existing and alternative turbulence promoters under selected operating conditions using a statistically designed test matrix; and Data reduction and analysis; The objective of Phase 3 research was to demonstrate the effectiveness of SpinTek's centrifugal membrane filtration as a pretreatment to remove suspended solids from a liquid waste upstream of 3M's WWL cartridge technology for the selective removal of technetium (Tc).

  16. Centrifugal Adsorption Cartridge System

    NASA Technical Reports Server (NTRS)

    Gonda, Steve R.; Tsao, Yow-Min D.; Lee, Wenshan

    2004-01-01

    The centrifugal adsorption cartridge system (CACS) is an apparatus that recovers one or more bioproduct(s) from a dilute aqueous solution or suspension flowing from a bioreactor. The CACS can be used both on Earth in unit gravity and in space in low gravity. The CACS can be connected downstream from the bioreactor; alternatively, it can be connected into a flow loop that includes the bioreactor so that the liquid can be recycled. A centrifugal adsorption cartridge in the CACS (see figure) includes two concentric cylinders with a spiral ramp between them. The volume between the inner and outer cylinders, and between the turns of the spiral ramp is packed with an adsorbent material. The inner cylinder is a sieve tube covered with a gas-permeable, hydrophobic membrane. During operation, the liquid effluent from the bioreactor is introduced at one end of the spiral ramp, which then constrains the liquid to flow along the spiral path through the adsorbent material. The spiral ramp also makes the flow more nearly uniform than it would otherwise be, and it minimizes any channeling other than that of the spiral flow itself. The adsorbent material is formulated to selectively capture the bioproduct(s) of interest. The bioproduct(s) can then be stored in bound form in the cartridge or else eluted from the cartridge. The centrifugal effect of the spiral flow is utilized to remove gas bubbles from the liquid. The centrifugal effect forces the bubbles radially inward, toward and through the membrane of the inner cylinder. The gas-permeable, hydrophobic membrane allows the bubbles to enter the inner cylinder while keeping the liquid out. The bubbles that thus enter the cylinder are vented to the atmosphere. The spacing between the ramps determines rate of flow along the spiral, and thereby affects the air-bubble-removal efficiency. The spacing between the ramps also determines the length of the fluid path through the cartridge adsorbent, and thus affects the bioproduct

  17. National geotechnical centrifuge

    NASA Technical Reports Server (NTRS)

    Hallam, J. A.; Kunz, N.; Vallotton, W. C.

    1982-01-01

    A high G-ton centrifuge, able to take a 2700 kg (6000 lb) payload up to 300 G, is described. The stability of dams and embankments, the bearing capacity of soil foundations, and the dynamic behavior of foundations due to vibration of machinery are examples of applications. A power rating of 6,000 kW (9,000 hp) was established for the motor. An acceptable maximum speed of 70 rpm was determined. A speed increase with a ratio of 1:3 is discussed. The isolated tension straps, the anti-spreader bar and the flexwall bucket, and safety precautions are also discussed.

  18. Centrifugal-reciprocating compressor

    NASA Technical Reports Server (NTRS)

    Higa, W. H. (Inventor)

    1984-01-01

    A centrifugal compressor is described which includes at least one pair of cylinders arranged in coaxial alignment and supported for angular displacement about a common axis of rotation normally disecting a common longitudinal axis of symmetry for the cylinders. The cylinders are characterized by ported closures located at the mutually remote ends thereof through which the cylinders are charged and discharged, and a pair of piston heads seated within the cylinders and supported for floating displacement in compressive strokes in response to unidirectional angular displacement imparted to the cylinders.

  19. Centrifuge impact cratering experiment 5

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Transient crates motions, cratering flow fields, crates dynamics, determining impact conditions from total crater welt, centrifuge quarter-space cratering, and impact cratering mechanics research is documented.

  20. Rapid determination of octanol-water partition coefficient using vortex-assisted liquid-liquid microextraction.

    PubMed

    Román, Iván P; Mastromichali, Anna; Tyrovola, Konstantina; Canals, Antonio; Psillakis, Elefteria

    2014-02-21

    Vortex-assisted liquid-liquid microextraction (VALLME) coupled with high-performance liquid chromatography (HPLC) is proposed here for the rapid determination of octanol-water partitioning coefficients (Kow). VALLME uses vortex agitation, a mild emulsification procedure, to disperse microvolumes of octanol in the aqueous phase thus increasing the interfacial contact area and ensuring faster partitioning rates. With VALLME, 2min were enough to achieve equilibrium conditions between the octanolic and aqueous phases. Upon equilibration, separation was achieved using centrifugation and the octanolic microdrop was collected and analyzed in a HPLC system. Six model compounds with logKow values ranging between ∼0.5 and 3.5 were used during the present investigations. The proposed method produced logKow values that were consistent with previously published values and the recorded uncertainty was well within the acceptable log unit range. Overall, the key features of the proposed Kow determination procedure comprised speed, reliability, simplicity, low cost and minimal solvent consumption.

  1. The Generally Useful Estimate of Solvent Systems (GUESS) method enables the rapid purification of methylpyridoxine regioisomers by countercurrent chromatography.

    PubMed

    Liu, Yang; Friesen, J Brent; Klein, Larry L; McAlpine, James B; Lankin, David C; Pauli, Guido F; Chen, Shao-Nong

    2015-12-24

    The TLC-based Generally Useful Estimate of Solvent Systems (GUESS) method was employed for countercurrent chromatography solvent system selection, in order to separate the three synthetic isomers: 3-O-methylpyridoxine, 4'-O-methylpyridoxine (ginkgotoxin), and 5'-O-methylpyridoxine. The Rf values of the three isomers indicated that ChMWat+2 (chloroform-methanol-water 10:5:5, v/v/v) was appropriate for the countercurrent separation. The isomer separation was highly selective and demonstrated that the TLC-based GUESS method can accelerate solvent system selection for countercurrent separation. Accordingly, the study re-emphasizes the practicality of TLC as a tool to facilitate the rapid development of new countercurrent and centrifugal partition chromatography methods for this solvent system. Purity and structure characterization of all samples was performed by quantitative (1)H NMR.

  2. Centrifuge treatment of coal tar

    SciTech Connect

    L.A. Kazak; V.Z. Kaidalov; L.F. Syrova; O.S. Miroshnichenko; A.S. Minakov

    2009-07-15

    New technology is required for the removal of water and heavy fractions from regular coal tar. Centrifuges offer the best option. Purification of coal tar by means of centrifuges at OAO NLMK permits the production of pitch coke or electrode pitch that complies with current standards.

  3. Unshrouded Centrifugal Turbopump Impeller

    NASA Technical Reports Server (NTRS)

    Prueger, George; Williams, Morgan; Chen, Wei; Paris, John; Stewart, Eric; Williams, Robert

    1999-01-01

    The ratio of rocket engine thrust to weight is a limiting constraint in placing more payload into orbit at a low cost. A key component of an engine's overall weight is the turbopump weight, Reducing the turbopump weight can result in significant engine weight reduction and hence, increased delivered payload. There are two main types of pumps: centrifugal and axial pumps. These types of pumps can be further sub-divided into those with shrouds and those without shrouds (unshrouded pumps). Centrifugal pumps can achieve the same pump discharge pressure as an axial pump and it requires fewer pump stages and lower pump weight than an axial pump. Also, with unshrouded centrifugal pumps (impeller), the number of stages and weight can be further reduced. However. there are several issues with regard to using an unshrouded impeller: 1) there is a pump performance penalty due to the front open face recirculation flow; 2) there is a potential pump axial thrust problem from the unbalanced front open face and the back shroud face; and, 3) since test data is very linu'ted for this configuration, there is uncertainty in the magnitude and phase of the rotordynamics forces due to the front impeller passage. The purpose of the paper is to discuss the design of an unshrouded impeller and to examine the design's hydrodynamic performance, axial thrust, and rotordynamics performance. The design methodology will also be discussed. This work will help provide some guidelines for unshrouded impeller design. In particular, the paper will discuss the design of three unshrouded impellers - one with 5 full and 5 partial blades (5+5). one with 6+6 blades and one with 8+8 blades. One of these designs will be selected for actual fabrication and flow test. Computational fluid dynamics (CFD) is used to help design and optimize the unshrouded impeller. The relative pump performance penalty is assessed by comparing the CFD results of the unshrouded impeller with the equivalent shrouded impeller for a

  4. Rat growth during chronic centrifugation

    NASA Technical Reports Server (NTRS)

    Pitts, G. C.; Oyama, J.

    1978-01-01

    Female weanling rats were chronically centrifuged at 4.15 G with controls at terrestrial gravity. Samples were sacrificed for body composition studies at 0, 28, 63, 105 and 308 days of centrifugation. The centrifuged group approached a significantly lower mature body mass than the controls (251 and 318g) but the rate of approach was the same in both groups. Retirement to 1G on the 60th day resulted in complete recovery. Among individual components muscle, bone, skin, CNS, heart, kidneys, body water and body fat were changed in the centrifuged group. However, an analysis of the growth of individual components relative to growth of the total fat-free compartment revealed that only skin (which increased in mass) was responding to centrifugation per se.

  5. [Galileo and centrifugal force].

    PubMed

    Vilain, Christiane

    This work intends to focus on Galileo's study of what is now called "centrifugal force," within the framework of the Second Day of his Dialogo written in 1632, rather than on the previously published commentaries on the topic. Galileo proposes three geometrical demonstrations in order to prove that gravity will always overcome centrifugalforce, and that the potential rotation of the Earth, whatever its speed, cannot in any case project objects beyond it. Each of these demonstrations must consequently contain an error and it has seemed to us that the first one had not been understood up until now. Our analysis offers an opportunity to return to Galileo's geometrical representation of dynamical questions; actually, we get an insight into the sophistication of Galileo's practices more than into his mistakes. Our second point, concerning the historiography of the problem, shows an evolution from anachronic critics to more contextual considerations, in the course of the second half of the twentieth century.

  6. Gas centrifuge purge method

    DOEpatents

    Theurich, Gordon R.

    1976-01-01

    1. In a method of separating isotopes in a high speed gas centrifuge wherein a vertically oriented cylindrical rotor bowl is adapted to rotate about its axis within an evacuated chamber, and wherein an annular molecular pump having an intake end and a discharge end encircles the uppermost portion of said rotor bowl, said molecular pump being attached along its periphery in a leak-tight manner to said evacuated chamber, and wherein end cap closure means are affixed to the upper end of said rotor bowl, and a process gas withdrawal and insertion system enters said bowl through said end cap closure means, said evacuated chamber, molecular pump and end cap defining an upper zone at the discharge end of said molecular pump, said evacuated chamber, molecular pump and rotor bowl defining a lower annular zone at the intake end of said molecular pump, a method for removing gases from said upper and lower zones during centrifuge operation with a minimum loss of process gas from said rotor bowl, comprising, in combination: continuously measuring the pressure in said upper zone, pumping gas from said lower zone from the time the pressure in said upper zone equals a first preselected value until the pressure in said upper zone is equal to a second preselected value, said first preselected value being greater than said second preselected value, and continuously pumping gas from said upper zone from the time the pressure in said upper zone equals a third preselected value until the pressure in said upper zone is equal to a fourth preselected value, said third preselected value being greater than said first, second and fourth preselected values.

  7. High Performance Liquid Chromatography

    NASA Astrophysics Data System (ADS)

    Talcott, Stephen

    High performance liquid chromatography (HPLC) has many applications in food chemistry. Food components that have been analyzed with HPLC include organic acids, vitamins, amino acids, sugars, nitrosamines, certain pesticides, metabolites, fatty acids, aflatoxins, pigments, and certain food additives. Unlike gas chromatography, it is not necessary for the compound being analyzed to be volatile. It is necessary, however, for the compounds to have some solubility in the mobile phase. It is important that the solubilized samples for injection be free from all particulate matter, so centrifugation and filtration are common procedures. Also, solid-phase extraction is used commonly in sample preparation to remove interfering compounds from the sample matrix prior to HPLC analysis.

  8. HOUSINGS AND MOUNTINGS FOR CENTRIFUGES

    DOEpatents

    Rushing, F.C.

    1960-08-16

    A protective housing for a gas centrifuge comprises a slidable connection between flanges and framework portions for absorbing rotational energy in case of bursting of the rotor and a sealing means for sealing the rotor chamber.

  9. Centrifugal dryers keep pace with the market

    SciTech Connect

    Fiscor, S.

    2008-03-15

    New plant design and upgrades create a shift in dewatering strategies. The article describes recent developments. Three major manufacturers supply centrifugal dryers - TEMA, Centrifugal & Mechanical Industries (CMI) and Ludowici. CMI introduced a line of vertical centrifugal dryers. TEMA improved the techniques by developing a horizontal vibratory centrifuge (HVC) which simplified maintenance. 3 figs., 1 photo.

  10. Microwave assisted centrifuge and related methods

    DOEpatents

    Meikrantz, David H [Idaho Falls, ID

    2010-08-17

    Centrifuge samples may be exposed to microwave energy to heat the samples during centrifugation and to promote separation of the different components or constituents of the samples using a centrifuge device configured for generating microwave energy and directing the microwave energy at a sample located in the centrifuge.

  11. Variable-Speed Instrumented Centrifuges

    NASA Technical Reports Server (NTRS)

    Chapman, David K.; Brown, Allan H.

    1991-01-01

    Report describes conceptual pair of centrifuges, speed of which varied to produce range of artificial gravities in zero-gravity environment. Image and data recording and controlled temperature and gravity provided for 12 experiments. Microprocessor-controlled centrifuges include video cameras to record stop-motion images of experiments. Potential applications include studies of effect of gravity on growth and on production of hormones in corn seedlings, experiments with magnetic flotation to separate cells, and electrophoresis to separate large fragments of deoxyribonucleic acid.

  12. Centrifugal Compressor Aeroelastic Analysis Code

    NASA Astrophysics Data System (ADS)

    Keith, Theo G., Jr.; Srivastava, Rakesh

    2002-01-01

    Centrifugal compressors are very widely used in the turbomachine industry where low mass flow rates are required. Gas turbine engines for tanks, rotorcraft and small jets rely extensively on centrifugal compressors for rugged and compact design. These compressors experience problems related with unsteadiness of flowfields, such as stall flutter, separation at the trailing edge over diffuser guide vanes, tip vortex unsteadiness, etc., leading to rotating stall and surge. Considerable interest exists in small gas turbine engine manufacturers to understand and eventually eliminate the problems related to centrifugal compressors. The geometric complexity of centrifugal compressor blades and the twisting of the blade passages makes the linear methods inapplicable. Advanced computational fluid dynamics (CFD) methods are needed for accurate unsteady aerodynamic and aeroelastic analysis of centrifugal compressors. Most of the current day industrial turbomachines and small aircraft engines are designed with a centrifugal compressor. With such a large customer base and NASA Glenn Research Center being, the lead center for turbomachines, it is important that adequate emphasis be placed on this area as well. Currently, this activity is not supported under any project at NASA Glenn.

  13. Using quantitative structure activity relationship models to predict an appropriate solvent system from a common solvent system family for countercurrent chromatography separation.

    PubMed

    Marsden-Jones, Siân; Colclough, Nicola; Garrard, Ian; Sumner, Neil; Ignatova, Svetlana

    2015-06-12

    Countercurrent chromatography (CCC) is a form of liquid-liquid chromatography. It works by running one immiscible solvent (mobile phase) over another solvent (stationary phase) being held in a CCC column using centrifugal force. The concentration of compound in each phase is characterised by the partition coefficient (Kd), which is the concentration in the stationary phase divided by the concentration in the mobile phase. When Kd is between approximately 0.2 and 2, it is most likely that optimal separation will be achieved. Having the Kd in this range allows the compound enough time in the column to be separated without resulting in a broad peak and long run time. In this paper we report the development of quantitative structure activity relationship (QSAR) models to predict logKd. The QSAR models use only the molecule's 2D structure to predict the molecular property logKd.

  14. CENTRIFUGAL MEMBRANE FILTRATION

    SciTech Connect

    William A. Greene; Patricia A. Kirk; Richard Hayes; Joshua Riley

    2005-10-28

    SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, has engineered and developed a system for use within the U.S. Department of Energy (DOE) Environmental Management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. SpinTek II High Shear Rotary Membrane Filtration System is a unique compact crossflow membrane system that has large, demonstrable advantages in performance and cost compared to currently available systems: (1) High fluid shear prevents membrane fouling even with very high solids content; hazardous and radioactive components can be concentrated to the consistency of a pasty slurry without fouling. (2) Induced turbulence and shear across the membrane increases membrane flux by a factor of ten over existing systems and allows operation on fluids not otherwise treatable. (3) Innovative ceramic membrane and mechanical sealing technology eliminates compatibility problems with aggressive DOE waste streams. (4) System design allows rapid, simple disassembly for inspection or complete decontamination. (5) Produces colloidal- and suspended-solids-free filtrate without the addition of chemicals. The first phase of this project (PRDA maturity stage 5) completed the physical scale-up of the SpinTek unit and verified successful scale-up with surrogate materials. Given successful scale-up and DOE concurrence, the second phase of this project (PRDA maturity stage 6) will provide for the installation and

  15. New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

    PubMed

    Shinomiya, Kazufusa; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2006-02-03

    The cross-axis coil planet centrifuge (X-axis CPC) is useful for partitioning macromolecules with aqueous-aqueous polymer phase systems. The floor model we have built with a pair of separation columns had some shortcomings such as requirement of large space, short life of the flow tubes, and difficulty in installing columns. In order to improve the partition efficiency and the utility of counter-current chromatography (CCC), a new small-scale X-axis CPC was designed and fabricated in our laboratory. The down-sizing of the apparatus was done by reducing the scale to about 1/2 of our original model of X-1.5L type with several improvements. Performance of the apparatus was evaluated on protein separation using an aqueous-aqueous polymer phase system composed of polyethylene glycol 1000 and dibasic potassium phosphate with four multilayer coiled columns. A series of experiments revealed that the combination of right- and left-handed coils produced the best partition efficiencies for both lower and upper mobile phases by selecting the revolution direction. The overall results indicate that the head-tail elution mode substantially affects to the peak resolution and stationary phase retention. This new X-axis CPC would be useful for the separation of various kinds of biologically active compounds.

  16. Plasmid Partition Mechanisms.

    PubMed

    Baxter, Jamie C; Funnell, Barbara E

    2014-12-01

    The stable maintenance of low-copy-number plasmids in bacteria is actively driven by partition mechanisms that are responsible for the positioning of plasmids inside the cell. Partition systems are ubiquitous in the microbial world and are encoded by many bacterial chromosomes as well as plasmids. These systems, although different in sequence and mechanism, typically consist of two proteins and a DNA partition site, or prokaryotic centromere, on the plasmid or chromosome. One protein binds site-specifically to the centromere to form a partition complex, and the other protein uses the energy of nucleotide binding and hydrolysis to transport the plasmid, via interactions with this partition complex inside the cell. For plasmids, this minimal cassette is sufficient to direct proper segregation in bacterial cells. There has been significant progress in the last several years in our understanding of partition mechanisms. Two general areas that have developed are (i) the structural biology of partition proteins and their interactions with DNA and (ii) the action and dynamics of the partition ATPases that drive the process. In addition, systems that use tubulin-like GTPases to partition plasmids have recently been identified. In this chapter, we concentrate on these recent developments and the molecular details of plasmid partition mechanisms.

  17. Centrifuge-Based Fluidic Platforms

    NASA Astrophysics Data System (ADS)

    Zoval, Jim; Jia, Guangyao; Kido, Horacio; Kim, Jitae; Kim, Nahui; Madou, Marc

    In this chapter centrifuge-based microfluidic platforms are reviewed and compared with other popular microfluidic propulsion methods. The underlying physical principles of centrifugal pumping in microfluidic systems are presented and the various centrifuge fluidic functions such as valving, decanting, calibration, mixing, metering, heating, sample splitting, and separation are introduced. Those fluidic functions have been combined with analytical measurements techniques such as optical imaging, absorbance and fluorescence spectroscopy and mass spectrometry to make the centrifugal platform a powerful solution for medical and clinical diagnostics and high-throughput screening (HTS) in drug discovery. Applications of a compact disc (CD)-based centrifuge platform analyzed in this review include: two-point calibration of an optode-based ion sensor, an automated immunoassay platform, multiple parallel screening assays and cellular-based assays. The use of modified commercial CD drives for high-resolution optical imaging is discussed as well. From a broader perspective, we compare the technical barriers involved in applying microfluidics for sensing and diagnostic as opposed to applying such techniques to HTS. The latter poses less challenges and explains why HTS products based on a CD fluidic platform are already commercially available, while we might have to wait longer to see commercial CD-based diagnostics.

  18. Hemolysis in different centrifugal pumps.

    PubMed

    Kawahito, K; Nosé, Y

    1997-04-01

    Different types of centrifugal pumps cause different amounts of hemolysis based on shear stress and blood exposure time. However, the hemolytic characteristics of centrifugal pumps in each clinical condition are not always clear. We compared the hemolytic characteristics of one cone-type centrifugal pump (Medtronic BioMedicus BP-80) and 2 impeller-type centrifugal pumps (Nikkiso HMS-12 and Terumo Capiox) under experimental conditions simulating their use in cardiopulmonary bypass (CPB), extracorporeal membrane oxygenation (ECMO), and percutaneous cardiopulmonary support (PCPS) as well as their use as left ventricular assist devices (LVADs). The normalized indexes of hemolysis (NIHs; grams free plasma hemoglobin per 100 L blood pumped) during use as LVADs were not significantly different among the 3 pumps. The BP-80 pump produced almost 3-fold more hemolysis than the HMS-12 and Capiox pumps during CPB, 3- to 4-fold more hemolysis during ECMO, and 5.5-fold more hemolysis during PCPS. The 2 impeller-type centrifugal pumps will therefore cause less hemolysis under high flow, high pressure difference (as in CPB) and low flow, high pressure difference (as in ECMO and PCPS) conditions than the cone-type pump.

  19. Centrifugal slip casting of components

    SciTech Connect

    Steinlage, G.A.; Roeder, R.K.; Trumble, K.P.; Bowman, K.J.

    1996-05-01

    Research in layered and functionally gradient materials has emerged because of the increasing demand for high-performance engineering materials. Many techniques have been used to produce layered and functionally gradient components. Common examples include thermal spray processing, powder processing, chemical and physical vapor deposition, high-temperature or combustion synthesis, diffusion treatments, microwave processing and infiltration. Of these techniques, powder processing routes offer excellent microstructural control and product quality, and they are capable of producing large components. Centrifugal slip casting is a powder-processing technique combining the effects of slip casting and centrifugation. In slip casting, consolidation takes place as fluid is removed by the porous mold. Particles within the slip move with the suspending fluid until reaching the mold wall, at which point they are consolidated. In centrifugation, particles within the slip move through the fluid at a rate dependent upon the gravitational force and particle drag.

  20. Centrifugation and the Manhattan Project

    NASA Astrophysics Data System (ADS)

    Reed, Cameron

    2009-05-01

    A study of U. S. Army Manhattan Engineer District documents reveals that consideration of centrifugation as a means of uranium enrichment during World War II was considerably more extensive than is commonly appreciated. By the time the centrifuge project was abandoned in early 1944 a full-scale prototype unit had been fabricated and tested at near-production speeds, enrichments of close to theoretically-expected levels had been demonstrated with pilot-plant units, and plans for production plants had been developed. This paper will review the history of this little-known aspect of the Project and examine the circumstances of how it came to be discontinued.

  1. Centrifugation and the Manhattan Project

    NASA Astrophysics Data System (ADS)

    Reed, Cameron

    2009-04-01

    A study of U. S. Army Manhattan Engineer District documents reveals that consideration of centrifugation as a means of uranium enrichment during World War II was considerably more extensive than is commonly appreciated. By the time the centrifuge project was abandoned in early 1944 a full-scale prototype unit had been fabricated and tested at near-production speeds, enrichments of close to theoretically-expected levels had been demonstrated with pilot-plant units, and plans for production plants had been developed. This paper will review the history of this little-known aspect of the Project and examine the circumstances of how it came to be discontinued.

  2. MEANS FOR DETERMINING CENTRIFUGE ALIGNMENT

    DOEpatents

    Smith, W.Q.

    1958-08-26

    An apparatus is presented for remotely determining the alignment of a centrifuge. The centrifage shaft is provided with a shoulder, upon which two followers ride, one for detecting radial movements, and one upon the shoulder face for determining the axial motion. The followers are attached to separate liquid filled bellows, and a tube connects each bellows to its respective indicating gage at a remote location. Vibrations produced by misalignment of the centrifuge shaft are transmitted to the bellows, and tbence through the tubing to the indicator gage. This apparatus is particularly useful for operation in a hot cell where the materials handled are dangerous to the operating personnel.

  3. Life Sciences Centrifuge Facility assessment

    NASA Technical Reports Server (NTRS)

    Benson, Robert H.

    1994-01-01

    This report provides an assessment of the status of the Centrifuge Facility being developed by ARC for flight on the International Space Station Alpha. The assessment includes technical status, schedules, budgets, project management, performance of facility relative to science requirements, and identifies risks and issues that need to be considered in future development activities.

  4. Life Sciences Centrifuge Facility review

    NASA Technical Reports Server (NTRS)

    Young, Laurence R.

    1994-01-01

    The Centrifuge Facility Project at ARC was reviewed by a code U team to determine appropriateness adequacy for the ISSA. This report represents the findings of one consultant to this team and concentrates on scientific and technical risks. This report supports continuation of the project to the next phase of development.

  5. Axial-Centrifugal Compressor Program

    DTIC Science & Technology

    1975-10-01

    We also wish to thank Robert Langworthy of the Eustis Directorate for his timely assistance and constructive guidance. 3, INj TABLE OF CONTENTS Page...34 PREFACE 3 LIST OF ILLUSTRATIONS ..................... 7 LIST OF TABLES . . . . . . . . . . . . . . . . . . . . . . . . . 17 INTRODUCTIONB...Blow Test. 132 Axial IGV Blow Test . . . . . . . . ........... 141 PMIZ ?crn AM BLANK-NOT 1=43D TABLE OF CONTENTS - Continued Centrifugal Compressor

  6. Centrifugal pumps for rocket engines

    NASA Technical Reports Server (NTRS)

    Campbell, W. E.; Farquhar, J.

    1974-01-01

    The use of centrifugal pumps for rocket engines is described in terms of general requirements of operational and planned systems. Hydrodynamic and mechanical design considerations and techniques and test procedures are summarized. Some of the pump development experiences, in terms of both problems and solutions, are highlighted.

  7. Laser and gas centrifuge enrichment

    SciTech Connect

    Heinonen, Olli

    2014-05-09

    Principles of uranium isotope enrichment using various laser and gas centrifuge techniques are briefly discussed. Examples on production of high enriched uranium are given. Concerns regarding the possibility of using low end technologies to produce weapons grade uranium are explained. Based on current assessments commercial enrichment services are able to cover the global needs of enriched uranium in the foreseeable future.

  8. A strategy for the separation of diterpenoid isomers from the root of Aralia continentalis by countercurrent chromatography: The distribution ratio as a substitute for the partition coefficient and a three-phase solvent system.

    PubMed

    Lee, Kyoung Jin; Song, Kwang Ho; Choi, Wonmin; Kim, Yeong Shik

    2015-08-07

    Aralia continentalis (Araliaceae) is widely used as a medicinal plant in East Asia. Previous studies have indicated that diterpenoid isomers (kaurenoic acid, continentalic acid, and ent-continentalic acid) are the major bioactive compounds of this plant. A new strategy was developed to alleviate difficulties in the separation of these isomers from this plant. A three-phase solvent system was applied to separate the isomers, and furthermore, the distribution ratio (Kc) was introduced as a substitute for the partition coefficient (KD). For compounds exhibiting a single equilibrium, their distributions in two immiscible phases were only affected by the partition coefficient of each solute. However, compounds that have a dissociating functional group (e.g., -COOH) are involved in two types of equilibrium in the two-phase system. In this case, the partitioning behaviors of the solutes are greatly affected by the pH of the solution. A mathematical prediction was applied for adjusting the solutions to the proper pH values. To prevent non-used phase (medium phase) waste, both the stationary phase (upper phase) and mobile phase (lower phase) were prepared on-demand without pre-saturation with the application of (1)H NMR. Each fraction obtained was collected and dried, yielding the following diterpenoid isomers from the 50mg injected sample: kaurenoic acid (19.7mg, yield: 39%) and ent-continentalic acid (21.3mg, yield: 42%).

  9. Microbial partitioning to settleable particles in stormwater.

    PubMed

    Characklis, Gregory W; Dilts, Mackenzie J; Simmons, Otto D; Likirdopulos, Christina A; Krometis, Leigh-Anne H; Sobsey, Mark D

    2005-05-01

    The degree to which microbes in the water column associate with settleable particles has important implications for microbial transport in receiving waters, as well as for microbial removal via sedimentation (i.e. detention basins). The partitioning behavior of several bacterial, protozoan and viral indicator organisms is explored in three urban streams under both storm and dry weather conditions. The fraction of organisms associated with settleable particles in stormwater is estimated through use of a centrifugation technique which is calibrated using suspensions of standard particles (e.g., glass, latex). The fraction of organisms associated with settleable particles varies by type of microbe, and the partitioning behavior of each organism generally changes between dry weather and storm conditions. Bacterial indicator organisms (fecal coliforms, Escherichia coli, enterococci) exhibited relatively consistent behavior, with an average of 20-35% of organisms associated with these particles in background samples and 30-55% in storm samples. Clostridium perfringens spores exhibited the highest average level of particle association, with storm values varying from 50% to 70%. Results related to total coliphage partitioning were more variable, with 20-60% associated with particles during storms. These estimates should be valuable in surface water quality modeling efforts, many of which currently assume that all microbes exist as free (unattached) organisms.

  10. Design of a centrifugal blood pump: Heart Turcica Centrifugal.

    PubMed

    Demir, Onur; Biyikli, Emre; Lazoglu, Ismail; Kucukaksu, Suha

    2011-07-01

    A prototype of a new implantable centrifugal blood pump system named Heart Turcica Centrifugal (HTC) was developed as a left ventricular assist device (LVAD) for the treatment of end-stage cardiac failure. In the development of HTC, effects of blade height and volute tongue profiles on the hydraulic and hemolytic performances of the pump were investigated. As a result, the prototype was manufactured using the best blade height and volute tongue profiles. Performance of the prototype model was experimentally evaluated in a closed-loop flow system using water as the medium. The hydraulic performance requirement of an LVAD (5 L/min flow rate against a pressure difference of 100 mm Hg) was attained at 2800 rpm rotational speed.

  11. Membrane solubility of chlorpromazine. Hygroscopic desorption and centrifugation methods yield comparable results.

    PubMed Central

    Luxnat, M; Müller, H J; Galla, H J

    1984-01-01

    Binding of the positively charged drug chlorpromazine to artificial and erythrocyte bilayer membranes was investigated by the filtration method called hygroscopic desorption [Conrad & Singer (1979) Proc. Natl. Acad. Sci. U.S.A. 76, 5202-5206] and by the conventional centrifugation method. Only minor differences in the partition coefficients were observed using the two methods. Our finding is not consistent with the observation of Conrad & Singer that amphipaths are completely excluded from biological membranes. However, the partition coefficient is dependent on membrane composition, which means dependent on the physical properties of a membrane. PMID:6525170

  12. Centrifugal separator devices, systems and related methods

    DOEpatents

    Meikrantz, David H [Idaho Falls, ID; Law, Jack D [Pocatello, ID; Garn, Troy G [Idaho Falls, ID; Todd, Terry A [Aberdeen, ID; Macaluso, Lawrence L [Carson City, NV

    2012-03-20

    Centrifugal separator devices, systems and related methods are described. More particularly, fluid transfer connections for a centrifugal separator system having support assemblies with a movable member coupled to a connection tube and coupled to a fixed member, such that the movable member is constrained to movement along a fixed path relative to the fixed member are described. Also, centrifugal separator systems including such fluid transfer connections are described. Additionally, methods of installing, removing and/or replacing centrifugal separators from centrifugal separator systems are described.

  13. When to maintain centrifugal pumps

    SciTech Connect

    Karassik, I.J.

    1993-04-01

    Centrifugal pumps comprise critical maintenance equipment. The rationale of when to maintain them relates to a spreading tendency to contain costs in the face of tight money. Plant managers are thus entitled to a thorough analysis of whether reduced expenditures truly lower costs or actually hinder maintenance and increase costs. Absence of such an analysis hides the fact that proper and timely maintenance has a double effect: it not only reduces power consumption but also extends equipment life, and thus reduces the frequency of labor and material expenditures for scheduled or crisis maintenance. Centrifugal pump maintenance can demonstrate well the validity of this observation. The paper discusses: restoring internal clearances; real cost of renewing clearances; and monitoring clearances and pump performance.

  14. Development of Advanced Centrifugal Pumps

    SciTech Connect

    Rohatgi, U.

    2009-09-30

    A CRADA project was performed between BNL and Flowserve, California, under the auspices of Initiative for Proliferation Prevention (IPP) with the DOE support. The purpose was to jointly support a team of Russian institutes led by Kurchatov Institute to develop technology to increase operating life of centrifugal pumps. The work was performed from March 1, 2002 to September 30, 2009. The project resulted in development and validation the total cost of the sub-contract with Kurchatov Institute was $700,000, with matching fund from the industrial partner, Flowserve. The technical objective of this project is to develop advanced centrifugal pumps for the power, petroleum, chemical and water services industries by increasing the reliability of pumping equipment without a corresponding increase in life cycle cost. This major market need can be served by developing centrifugal pumps that generate only modest forces on the mechanical system even when operating under significant off-design conditions. This project is focused towards understanding the origin of hydraulic forces (both radial and axial, steady and time-dependent) and to develop design options, which reduce these forces over a broad flow range. This focus will include the force generation due to cavitation inside the pump as the operating conditions extend to low suction pressures. The results of research will reduce the inception of cavitation that leads to surface erosion and to find passive method of reducing peaks in axial thrust during whole range of flow rates.

  15. Twinning of amphibian embryos by centrifugation

    NASA Technical Reports Server (NTRS)

    Black, S. D.

    1984-01-01

    In the frog Xenopus laevis, the dorsal structures of the embryonic body axis normally derive from the side of the egg opposite the side of sperm entry. However, if the uncleaved egg is inclined at lg or centrifuged in an inclined position, this topographic relationship is overridden: the egg makes its dorsal axial structures according to its orientation in the gravitational/centrifugal field, irrespective of the position of sperm entry. Certain conditions of centrifugation cause eggs to develop into conjoined twins with two sets of axial structures. A detailed analysis of twinning provided some insight into experimental axis orientation. First, as with single-axis embryos, both axes in twins are oriented according to the direction of centrifugation. One axis forms at the centripetal side of the egg and the other forms at the centrifugal side, even when the side of sperm entry is normal to the centrifugal force vector. Second, if eggs are centrifuged to give twins, but are inclined at lg to prevent post-centrifugation endoplasmic redistributions, only single-axis embryos develop. Thus, a second redistribution is required for high-frequency secondary axis formation. This can be accomplished by lg (as in the single centrifugations) or by a second centrifugation directed along the egg's animal-vegetal axis.

  16. Spiral Countercurrent Chromatography

    PubMed Central

    Ito, Yoichiro; Knight, Martha; Finn, Thomas M.

    2013-01-01

    For many years, high-speed countercurrent chromatography conducted in open tubing coils has been widely used for the separation of natural and synthetic compounds. In this method, the retention of the stationary phase is solely provided by the Archimedean screw effect by rotating the coiled column in the centrifugal force field. However, the system fails to retain enough of the stationary phase for polar solvent systems such as the aqueous–aqueous polymer phase systems. To address this problem, the geometry of the coiled channel was modified to a spiral configuration so that the system could utilize the radially acting centrifugal force. This successfully improved the retention of the stationary phase. Two different types of spiral columns were fabricated: the spiral disk assembly, made by stacking multiple plastic disks with single or four interwoven spiral channels connected in series, and the spiral tube assembly, made by inserting the tetrafluoroethylene tubing into a spiral frame (spiral tube support). The capabilities of these column assemblies were successfully demonstrated by separations of peptides and proteins with polar two-phase solvent systems whose stationary phases had not been well retained in the earlier multilayer coil separation column for high-speed countercurrent chromatography. PMID:23833207

  17. CENTRIFUGES

    DOEpatents

    Beams, J.W.; Snoddy, L.B.

    1960-08-01

    Damping bearings for use on the shafts of an ultracentrifuge were designed which are capable of passing through critical angular speeds. The shaft extending from one end of the rotor is journaled in fixed-plain bearings mounted on annular resilient shock-absorbing elements to dampen small vibrations. The shaft at the other end of the rotor is journaled in two damper-bearing assemblies which are so spaced on the shaft that a vibration node can at no time exist at both bearing assemblies. These bearings are similar to the other bearings except that the bearing housings are slidably mounted on the supporting structure for movement transverse to the rotational axis of the rotor.

  18. Partitioning Breaks Communities

    NASA Astrophysics Data System (ADS)

    Reid, Fergal; McDaid, Aaron; Hurley, Neil

    Considering a clique as a conservative definition of community structure, we examine how graph partitioning algorithms interact with cliques. Many popular community-finding algorithms partition the entire graph into non-overlapping communities. We show that on a wide range of empirical networks, from different domains, significant numbers of cliques are split across the separate partitions produced by these algorithms. We then examine the largest connected component of the subgraph formed by retaining only edges in cliques, and apply partitioning strategies that explicitly minimise the number of cliques split. We further examine several modern overlapping community finding algorithms, in terms of the interaction between cliques and the communities they find, and in terms of the global overlap of the sets of communities they find. We conclude that, due to the connectedness of many networks, any community finding algorithm that produces partitions must fail to find at least some significant structures. Moreover, contrary to traditional intuition, in some empirical networks, strong ties and cliques frequently do cross community boundaries; much community structure is fundamentally overlapping and unpartitionable in nature.

  19. Centrifugal separators and related devices and methods

    DOEpatents

    Meikrantz, David H [Idaho Falls, ID; Law, Jack D [Pocatello, ID; Garn, Troy G [Idaho Falls, ID; Macaluso, Lawrence L [Carson City, NV; Todd, Terry A [Aberdeen, ID

    2012-03-06

    Centrifugal separators and related methods and devices are described. More particularly, centrifugal separators comprising a first fluid supply fitting configured to deliver fluid into a longitudinal fluid passage of a rotor shaft and a second fluid supply fitting sized and configured to sealingly couple with the first fluid supply fitting are described. Also, centrifugal separator systems comprising a manifold having a drain fitting and a cleaning fluid supply fitting are described, wherein the manifold is coupled to a movable member of a support assembly. Additionally, methods of cleaning centrifugal separators are described.

  20. Applying Chromatography.

    ERIC Educational Resources Information Center

    Klein, Jessie W.; Patev, Paul

    1998-01-01

    Presents three experiments to introduce students to different kinds of chromatography: (1) paper chromatography; (2) gel filtration chromatography; and (3) reverse-phase liquid chromatography. Written in the form of a laboratory manual, explanations of each of the techniques, materials needed, procedures, and a glossary are included. (PVD)

  1. Immiscible silicate liquid partition coefficients: implications for crystal-melt element partitioning and basalt petrogenesis

    NASA Astrophysics Data System (ADS)

    Veksler, Ilya V.; Dorfman, Alexander M.; Danyushevsky, Leonid V.; Jakobsen, Jakob K.; Dingwell, Donald B.

    2006-12-01

    This study investigates partitioning of elements between immiscible aluminosilicate and borosilicate liquids using three synthetic mixtures doped with 32 trace elements. In order to get a good spatial separation of immiscible liquids, we employed a high-temperature centrifuge. Experiments were performed at 1,050-1,150°C, 1 atm, in sealed Fe and Pt containers. Quenched products were analysed by electron microprobe and LA ICP-MS. Nernst partition coefficients ( D’s) between the Fe-rich and Si-rich aluminosilicate immiscible liquids are the highest for Zn (3.3) and Fe (2.6) and the lowest for Rb and K (0.4-0.5). The plots of D values against ionic potential Z/r in all the compositions show a convex upward trend, which is typical also for element partitioning between immiscible silicate and salt melts. The results bear upon the speciation and structural position of elements in multicomponent silicate liquids. The ferrobasalt-rhyolite liquid immiscibility is observed in evolved basaltic magmas, and may play an important role in large gabbroic intrusions, such as Skaergaard, and during the generation of unusual lavas, such as ferropicrites.

  2. Iron Partitioning in Ferropericlase

    NASA Astrophysics Data System (ADS)

    Braithwaite, J. W. H.; Stixrude, L. P.; Pinilla, C.; Holmstrom, E.

    2015-12-01

    Ferropericlase, (Mg,Fe)O, is the second most abundant mineral in the Earth's lower mantle. Whether iron favours the liquid or solid phase of (Mg,Fe)O has important implications for the Earth's mantle, both chemically and dynamically. As iron is much heavier than magnesium, the partitioning of iron between liquid and solid will lead to a contrast in densities. This difference in density will lead one phase to be more buoyant than the other and would help, in part, to explain how the mantle crystallised from the magma ocean of the Hadean eon to its current state. The partitioning of iron between the two phases is characterized by partition coefficients. Using ab-initio methods, thermodynamic integration and adiabatic switching these coefficients have been determined. Results are presented for pressures encompassing the region between the upper mantle and the core-mantle boundary (10-140GPa).

  3. Design Attributes and Scale Up Testing of Annular Centrifugal Contactors

    SciTech Connect

    David H. Meikrantz; Jack D. Law

    2005-04-01

    Annular centrifugal contactors are being used for rapid yet efficient liquid- liquid processing in numerous industrial and government applications. Commercialization of this technology began eleven years ago and now units with throughputs ranging from 0.25 to 700 liters per minute are readily available. Separation, washing, and extraction processes all benefit from the use of this relatively new commercial tool. Processing advantages of this technology include: low in-process volume per stage, rapid mixing and separation in a single unit, connection-in-series for multi-stage use, and a wide operating range of input flow rates and phase ratios without adjustment. Recent design enhancements have been added to simplify maintenance, improve inspection ability, and provide increased reliability. Cartridge-style bearing and mechanical rotary seal assemblies that can include liquid-leak sensors are employed to enhance remote operations, minimize maintenance downtime, prevent equipment damage, and extend service life. Clean-in-place capability eliminates the need for disassembly, facilitates the use of contactors for feed clarification, and can be automated for continuous operation. In nuclear fuel cycle studies, aqueous based separations are being developed that efficiently partition uranium, actinides, and fission products via liquid-liquid solvent extraction. Thus, annular centrifugal contactors are destined to play a significant role in the design of such new processes. Laboratory scale studies using mini-contactors have demonstrated feasibility for many such separation processes but validation at an engineering scale is needed to support actual process design.

  4. FNAS phase partitions

    NASA Technical Reports Server (NTRS)

    Vanalstine, James M.

    1993-01-01

    Project NAS8-36955 D.O. #100 initially involved the following tasks: (1) evaluation of various coatings' ability to control wall wetting and surface zeta potential expression; (2) testing various methods to mix and control the demixing of phase systems; and (3) videomicroscopic investigation of cell partition. Three complementary areas were identified for modification and extension of the original contract. They were: (1) identification of new supports for column cell partition; (2) electrokinetic detection of protein adsorption; and (3) emulsion studies related to bioseparations.

  5. Apparatus for centrifugal separation of coal particles

    SciTech Connect

    Dickie, William; Cavallaro, Joseph A.; Killmeyer, Richard P.

    1991-01-01

    A gravimetric cell for centrifugal separation of fine coal by density has a cylindrical body and a butterfly valve or other apparatus for selectively sealing the body radially across the approximate center of the cylinder. A removable top is provided which seals the cylinder in the centrifuge and in unvented areas.

  6. Rotor for centrifugal fast analyzers

    DOEpatents

    Lee, N.E.

    1984-01-01

    The invention is an improved photometric analyzer of the rotary cuvette type, the analyzer incorporating a multicuvette rotor of novel design. The rotor (a) is leaktight, (b) permits operation in the 90/sup 0/ and 180/sup 0/ excitation modes, (c) is compatible with extensively used Centrifugal Fast Analyzers, and (d) can be used thousands of times. The rotor includes an assembly comprising a top plate, a bottom plate, and a central plate, the rim of the central plate being formed with circumferentially spaced indentations. A uv-transmitting ring is sealably affixed to the indented rim to define with the indentations an array of cuvettes. The ring serves both as a sealing means and an end window for the cuvettes.

  7. Rotor for centrifugal fast analyzers

    DOEpatents

    Lee, Norman E.

    1985-01-01

    The invention is an improved photometric analyzer of the rotary cuvette type, the analyzer incorporating a multicuvette rotor of novel design. The rotor (a) is leaktight, (b) permits operation in the 90.degree. and 180.degree. excitation modes, (c) is compatible with extensively used Centrifugal Fast Analyzers, and (d) can be used thousands of times. The rotor includes an assembly comprising a top plate, a bottom plate, and a central plate, the rim of the central plate being formed with circumferentially spaced indentations. A UV-transmitting ring is sealably affixed to the indented rim to define with the indentations an array of cuvettes. The ring serves both as a sealing means and an end window for the cuvettes.

  8. Centrifuges in gravitational physiology research

    NASA Technical Reports Server (NTRS)

    Ballard, Rodney W.; Davies, Phil; Fuller, Charles A.

    1993-01-01

    Data from space flight and ground based experiments have clearly demonstrated the importance of Earth gravity for normal physiological function in man and animals. Gravitational Physiology is concerned with the role and influence of gravity on physiological systems. Research in this field examines how we perceive and respond to gravity and the mechanisms underlying these responses. Inherent in our search for answers to these questions is the ability to alter gravity, which is not physically possible without leaving Earth. However, useful experimental paradigms have been to modify the perceived force of gravity by changing either the orientation of subjects to the gravity vector (i.e., postural changes) or by applying inertial forces to augment the magnitude of the gravity vector. The later technique has commonly been used by applying centripetal force via centrifugation.

  9. Centrifugal membrane filtration -- Task 9

    SciTech Connect

    1996-08-01

    The Energy and Environmental Research Center (EERC) has teamed with SpinTek Membrane Systems, Inc., the developer of a centrifugal membrane filtration technology, to demonstrate applications for the SpinTek technology within the US Department of Energy (DOE) Environmental management (EM) Program. The technology uses supported microporous membranes rotating at high rpm, under pressure, to separate suspended and colloidal solids from liquid streams, yielding a solids-free permeate stream and a highly concentrated solids stream. This is a crosscutting technology that falls under the Efficient Separations and Processing Crosscutting Program, with potential application to tank wastes, contaminated groundwater, landfill leachate, and secondary liquid waste streams from other remediation processes, including decontamination and decommissioning systems. Membrane-screening tests were performed with the SpinTek STC-X4 static test cell filtration unit, using five ceramic membranes with different pore size and composition. Based on permeate flux, a 0.25-{micro}m TiO{sub 2}/Al{sub 2}O{sub 3} membrane was selected for detailed performance evaluation using the SpinTek ST-IIL centrifugal membrane filtration unit with a surrogate tank waste solution. An extended test run of 100 hr performed on a surrogate tank waste solution showed some deterioration in filtration performance, based on flux, apparently due to the buildup of solids near the inner portion of the membrane where relative membrane velocities were low. Continued testing of the system will focus on modifications to the shear pattern across the entire membrane surface to affect improved long-term performance.

  10. Centrifuge workers study. Phase II, completion report

    SciTech Connect

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom.

  11. Gas dynamics in strong centrifugal fields

    SciTech Connect

    Bogovalov, S.V.; Kislov, V.A.; Tronin, I.V.

    2015-03-10

    Dynamics of waves generated by scopes in gas centrifuges (GC) for isotope separation is considered. The centrifugal acceleration in the GC reaches values of the order of 106g. The centrifugal and Coriolis forces modify essentially the conventional sound waves. Three families of the waves with different polarisation and dispersion exist in these conditions. Dynamics of the flow in the model GC Iguasu is investigated numerically. Comparison of the results of the numerical modelling of the wave dynamics with the analytical predictions is performed. New phenomena of the resonances in the GC is found. The resonances occur for the waves polarized along the rotational axis having the smallest dumping due to the viscosity.

  12. Comparison of lipid membrane-water partitioning with various organic solvent-water partitions of neutral species and ionic species: Uniqueness of cerasome as a model for the stratum corneum in partition processes.

    PubMed

    Zhang, Keda; Fahr, Alfred; Abraham, Michael H; Acree, William E; Tobin, Desmond J; Liu, Xiangli

    2015-10-15

    Lipid membrane-water partitions (e.g., immobilized artificial membrane systems where the lipid membrane is a neutral phospholipid monolayer bound to gel beads) were compared to various organic solvent-water partitions using linear free energy relationships. To this end, we also measured the retention factors of 36 compounds (including neutral and ionic species) from water to liposomes made up of 3-sn-phosphatidylcholine and 3-sn-phosphatidyl-l-serine (80:20, mol/mol), employing liposome electrokinetic chromatography in this work. The results show that lipid membranes exhibit a considerably different chemical environment from those of organic solvents. For both neutral species and ionic species, partitions into the more polar hydroxylic solvents are chemically closer to partition into the lipid membrane as compared to partitions into the less polar hydroxylic solvents and into aprotic solvents. This means that solutes partition into the polar parts of lipid membranes, regardless of whether they are charged or not. In addition, cerasome (i.e., liposome composed mainly of stratum corneum lipids) was compared with regular phospholipid liposomes as a possible model for human stratum corneum in partitions. It was found that the cerasome-water partition exhibits a better chemical similarity to skin permeation. This is probably due to the unique structures of ceramides that occur in cerasome and in the stratum corneum lipid domain. We further show that membranes in membrane-water partitions exhibit very different properties.

  13. Modeling of Centrifugal Force Field and the Effect on Filling and Solidification in Centrifugal Casting

    NASA Astrophysics Data System (ADS)

    Sheng, Wenbin; Ma, Chunxue; Gu, Wanli

    2011-06-01

    Based on the steady flow in a tube, a mathematical model has been established for the consideration of centrifuging force field by combining the equations of continuity, conservation of momentum and general energy. Effects of centrifugal field on the filling and solidification are modeled by two accessional terms: centrifugal force and Chorios force. In addition, the transfer of heat by convection is considered to achieve a coupling calculation of velocity field and temperature field. The solution of pressure item is avoided by introducing the stream function ψ(x,y) and the eddy function ξ(x,y). Corresponding difference formats for the simultaneous equations of centrifugal filling, the accessional terms and the solidifying latent heat have been established by the finite difference technique. Furthermore, the centrifugal filling and solidification processes in a horizontal tube are summarized to interpret the mechanism by which internal defects are formed in centrifugal castings.

  14. Gas centrifuge with driving motor

    DOEpatents

    Dancy, Jr., William H.

    1976-01-01

    1. A centrifuge for separating gaseous constituents of different masses comprising a vertical tubular rotor, means for introducing a gas mixture of different masses into said rotor and means for removing at least one of the gas components from the rotor, a first bearing means supporting said rotor at one end for rotational movement, a support, a damping bearing mounted on said support, a shaft fixed to said rotor at the opposite end and mechanically connecting said rotor to said damping bearing, a cup-shaped tube of electrically conductive, non-magnetic material in coaxial relationship with said shaft, the open end of said tube extending away from said rotor and the closed end of said tube being directly secured to the adjacent end of the rotor, an annular core of magnetic material fixedly mounted on said support so as to be disposed within said tube and around said shaft, and a second annular magnetic core with coils arranged thereon to receive polyphase current to produce a rotating magnetic field traversing the circumference of said tube, fixedly mounted on said support so as to surround said tube, the size of said first annular core and said second annular core being such as to permit limited radial displacement of said shaft and said tube.

  15. Two-Stage Centrifugal Fan

    NASA Technical Reports Server (NTRS)

    Converse, David

    2011-01-01

    Fan designs are often constrained by envelope, rotational speed, weight, and power. Aerodynamic performance and motor electrical performance are heavily influenced by rotational speed. The fan used in this work is at a practical limit for rotational speed due to motor performance characteristics, and there is no more space available in the packaging for a larger fan. The pressure rise requirements keep growing. The way to ordinarily accommodate a higher DP is to spin faster or grow the fan rotor diameter. The invention is to put two radially oriented stages on a single disk. Flow enters the first stage from the center; energy is imparted to the flow in the first stage blades, the flow is redirected some amount opposite to the direction of rotation in the fixed stators, and more energy is imparted to the flow in the second- stage blades. Without increasing either rotational speed or disk diameter, it is believed that as much as 50 percent more DP can be achieved with this design than with an ordinary, single-stage centrifugal design. This invention is useful primarily for fans having relatively low flow rates with relatively high pressure rise requirements.

  16. Optical detection strategies for centrifugal microfluidic platforms

    NASA Astrophysics Data System (ADS)

    King, Damien; O'Sullivan, Mary; Ducrée, Jens

    2014-01-01

    Centrifugal microfluidic systems have become one of the principal platforms for implementing bioanalytical assays, most notably for biomedical point-of-care diagnostics. These so-called 'lab-on-a-disc' systems primarily utilise the rotationally controlled centrifugal field in combination with capillary forces to automate a range of laboratory unit operations (LUOs) for sample preparation, such as metering, aliquoting, mixing and extraction for biofluids as well as sorting, isolation and counting of bioparticles. These centrifugal microfluidic LUOs have been regularly surveyed in the literature. However, even though absolutely essential to provide true sample-to-answer functionality of lab-on-a-disc platforms, systematic examination of associated, often optical, read-out technologies has been so far neglected. This review focusses on the history and state-of-the-art of optical read-out strategies for centrifugal microfluidic platforms, arising (commercial) application potential and future opportunities.

  17. Combination Of Investment And Centrifugal Casting

    NASA Technical Reports Server (NTRS)

    Creeger, Gordon A.

    1994-01-01

    Modifications, including incorporation of centrifugal casting, made in investment-casting process reducing scrap rate. Used to make first- and second-stage high-pressure-fuel-turbopump nozzles, containing vanes with thin trailing edges and other thin sections. Investment mold spun for short time while being filled, and stopped before solidification occurs. Centrifugal force drives molten metal into thin trailing edges, ensuring they are filled. With improved filling, preheat and pour temperatures reduced and solidification hastened so less hot tearing.

  18. Renal Response to Chronic Centrifugation in Rats

    NASA Technical Reports Server (NTRS)

    Ortiz, Rudy M.; Wang, T. J.; Corbin, B. J.; Wade, C. E.; Hargens, Alan R. (Technical Monitor)

    1996-01-01

    Previously reported effects of chronic centrifugation on renal function in mammals are contradictory. The present study was conducted as an effort to provide a comprehensive analysis of renal response to chronic centrifugation (12 days at +2 Gz). Sixteen male Sprague-Dawley rats (210-230 g) were used: eight centrifuged (EC) and eight off centrifuge controls (OCC). During centrifugation EC had lower body weight and food consumption. EC showed a decrease (72%) in water intake for the first two days (T1 and T2) followed by significant increases from T4-T6. EC urine output increased two-fold over the first four days, returning to baseline by T9. EC urea excretion was elevated on T3 through T5. Creatinine, Na(+), K(+), and osmolar excretion were lower than OCC over the last four days of the study. Assuming constant plasma osmolarity and creatinine levels, EC free water clearance (C(sub H2O)) was elevated significantly on T4 when the peak urine output was exhibited. EC also had a greater C(sub H2O) over the last four days, associated with a significantly lower osmolar clearance and GFR. The initial diuresis exhibited during centrifugation can be attributed to a reduced water resorption and increased urea excretion. This diuresis was mediated independent of changes in GFR over the first eight days. However, differences in excretion seen after eight days of centrifugation are probably GFR mediated which would imply animals established a new homeostatic setpoint by that time. Centrifugation elicites an acute alteration in fluid homeostasis followed by adaptation within a week.

  19. Chemical amplification based on fluid partitioning

    DOEpatents

    Anderson, Brian L.; Colston, Jr., Billy W.; Elkin, Chris

    2006-05-09

    A system for nucleic acid amplification of a sample comprises partitioning the sample into partitioned sections and performing PCR on the partitioned sections of the sample. Another embodiment of the invention provides a system for nucleic acid amplification and detection of a sample comprising partitioning the sample into partitioned sections, performing PCR on the partitioned sections of the sample, and detecting and analyzing the partitioned sections of the sample.

  20. Partitioning the Quaternary

    NASA Astrophysics Data System (ADS)

    Gibbard, Philip L.; Lewin, John

    2016-11-01

    We review the historical purposes and procedures for stratigraphical division and naming within the Quaternary, and summarize the current requirements for formal partitioning through the International Commission on Stratigraphy (ICS). A raft of new data and evidence has impacted traditional approaches: quasi-continuous records from ocean sediments and ice cores, new numerical dating techniques, and alternative macro-models, such as those provided through Sequence Stratigraphy and Earth-System Science. The practical usefulness of division remains, but there is now greater appreciation of complex Quaternary detail and the modelling of time continua, the latter also extending into the future. There are problems both of commission (what is done, but could be done better) and of omission (what gets left out) in partitioning the Quaternary. These include the challenge set by the use of unconformities as stage boundaries, how to deal with multiphase records in ocean and terrestrial sediments, what happened at the 'Early-Mid- (Middle) Pleistocene Transition', dealing with trends that cross phase boundaries, and the current controversial focus on how to subdivide the Holocene and formally define an 'Anthropocene'.

  1. Measurement and analysis of the mannitol partition coefficient in sucrose crystallization under simulated industrial conditions.

    PubMed

    Eggleston, Gillian; Yen, Jenny Wu Tiu; Alexander, Clay; Gober, Jessica

    2012-07-01

    Mannitol is a major deterioration product of Leuconstoc mesenteroides bacterial metabolism of sucrose and fructose from both sugarcane and sugar beet. The effect of crystallization conditions on the mannitol partition coefficient (K(eff)) between impure sucrose syrup and crystal has been investigated in a batch laboratory crystallizer and a batch pilot plant-scale vacuum pan. Laboratory crystallization was operated at 65.5°C (150°F), 60.0°C (140°F), and 51.7°C (125°F) with a 78.0 Brix (% refractometric dissolved solids) pure sucrose syrup containing 0%, 0.1%, 0.2%, 1.0%, 2.0%, 3.0%, and 10% (at 65.5°C only) mannitol on a Brix basis. Produced mother liquor and crystals were separated by centrifugation and their mannitol contents measured by ion chromatography with integrated pulsed amperometric detection (IC-IPAD). The extent of mannitol partitioning into the crystals depended strongly on the mannitol concentration in the feed syrup and, to a lesser extent, the crystallization temperature. At 65.5 and 60.0°C, the K(eff) varied from ~0.4% to 3.0% with 0.2% to 3.0% mannitol in the feed syrup, respectively. The mannitol K(eff) was lower than that reported for dextran (~9-10% K(eff)), another product of Leuconstoc deterioration, under similar sucrose crystal growth conditions. At 10% mannitol concentration in the syrup at 65.5°C, co-crystallization of mannitol with sucrose occurred and the crystal growth rate was greatly impeded. In both laboratory and pilot plant crystallizations (95.7% purity; 78.0 Brix; 65.5°C), mannitol tended to cause conglomerates to form, which became progressively worse with increased mannitol syrup concentration. At the 3% mannitol concentration, crystallization at both the laboratory and pilot plant scales was more difficult. Mannitol incorporation into the sucrose crystal results mostly from liquid syrup inclusions but adsorption onto the crystal surface may play a minor role at lower mannitol concentrations.

  2. Gas Chromatography.

    ERIC Educational Resources Information Center

    Karasek, Francis W.; And Others

    1984-01-01

    This review covers fundamental developments in gas chromatography during 1982 and 1983. Literature is considered under these headings: columns; liguid phases; solid supports; sorption processes and solvents; open tubular column gas chromatography; instrumentation; high-resolution columns and applications; other techniques; qualitative and…

  3. MHD Stability of Centrifugally Confined Plasmas

    NASA Astrophysics Data System (ADS)

    Huang, Yi-Min

    2003-10-01

    Centrifugally confined plasmas utilize centrifugal forces from plasma rotation to augment magnetic confinement, as an alternative approach to fusion. One magnetic geometry is mirror-type, with rotation about the axis induced from a central, biased core conductor. The outward centrifugal forces from the rotation have a component along the field lines, thus confining ions to the center. The immediate concern, of course, is that the system could be flute unstable to the interchange. The antidote here is that the radial shear in the rotation could stabilize the flute. Our 2D simulations show, first, that plasma pressure is highly peaked at the center away from the mirror end coils. Next, 3D simulations show unequivocally that velocity shear is providing the stability. Further study indicates that the flute stability is sensitive to the density profile. A favorable density profile could be achieved by judiciously placing the particle source, also necessary for a steady state centrifuge. As flows approach the Alfven speed, electromagnetic modes could be involved. The latter is motivated by the question of whether magnetorotational instability, thought to be an angular momentum transporter in accretion disks, could be found in centrifugal plasmas, since all the ingredients are there. We show that the MRI as understood should be stable; however, a related astrophysical instability, the Parker instability, could arise. The Parker instability results in plasma accumulating in regions of bent field lines, further accentuating the bending.

  4. Centrifugal techniques for measuring saturated hydraulic conductivity

    USGS Publications Warehouse

    Nimmo, John R.; Mello, Karen A.

    1991-01-01

    Centrifugal force is an alternative to large pressure gradients for the measurement of low values of saturated hydraulic conductivity (Ksat). With a head of water above a porous medium in a centrifuge bucket, both constant-head and falling-head measurements are practical at forces up to at least 1800 times normal gravity. Darcy's law applied to the known centrifugal potential leads to simple formulas for Ksat that are analogous to those used in the standard gravity-driven constant- and falling-head methods. Both centrifugal methods were tested on several fine-textured samples of soil and ceramic with Ksat between about 10−10 and 10−9 m/s. The results were compared to falling-head gravity measurements. The comparison shows most measurements agreeing to within 20% for a given sample, much of the variation probably resulting from run-to-run changes in sample structure. The falling-head centrifuge method proved to be especially simple in design and operation and was more accurate than the constant-head method. With modified apparatus, Ksat measurements less than 10−10 m/s should be attainable.

  5. Partition Density Functional Theory

    NASA Astrophysics Data System (ADS)

    Wasserman, Adam

    2012-02-01

    Partition Density Functional Theory (PDFT) is a formally exact method for obtaining molecular properties from self-consistent calculations on isolated fragments [1,2]. For a given choice of fragmentation, PDFT outputs the (in principle exact) molecular energy and density, as well as fragment densities that sum to the correct molecular density. I describe our progress understanding the behavior of the fragment energies as a function of fragment occupations, derivative discontinuities, practical implementation, and applications of PDFT to small molecules. I also discuss implications for ground-state Density Functional Theory, such as the promise of PDFT to circumvent the delocalization error of approximate density functionals. [4pt] [1] M.H. Cohen and A. Wasserman, J. Phys. Chem. A, 111, 2229(2007).[0pt] [2] P. Elliott, K. Burke, M.H. Cohen, and A. Wasserman, Phys. Rev. A 82, 024501 (2010).

  6. Partitioning: splitting fact from fiction.

    PubMed

    Pike, Brian

    2012-05-01

    Many larger hospitals are sprawling complexes with endless corridors and rooms of varying purpose. While cleanliness and infection control are, understandably, leading considerations in any hospital building, fire safety also plays a crucial role. Here Brian Pike MBE, technical consultant at partitioning system designer and manufacturer, Komfort Workspace, looks at how current fire guidelines impact on the use of partitioning systems in hospital premises.

  7. Effects of chronic centrifugation on mice

    NASA Technical Reports Server (NTRS)

    Janer, L.; Duke, J.

    1984-01-01

    Previous studies have shown that exposure to excess gravity in vitro alters the developmental sequence in embryonic mouse limbs and palates (Duke, Janer and Campbell, 1984; Duke, 1983). The effects of excess gravity on in vivo mammalian development was investigated using a small animal centrifuge. Four-week old female mice exposed to excess gravities of 1.8-3.5 G for eight weeks weighed significantly less than controls. Mice were mated after five weeks of adaptation to excess G, and sacrificed either at gestational day 12 or 18. There were fewer pregnancies in the centrifuged group (4/36) than in controls (9/31), and crown rump lengths (CRL) of embryos developing in the centrifuge were less than CRLs of 1-G embryos. These results show that although immersed in amniotic fluid, embryos are responsive to Delta-G.

  8. Possible segregation caused by centrifugal titanium casting.

    PubMed

    Watanabe, K; Okawa, S; Kanatani, M; Nakano, S; Miyakawa, O; Kobayashi, M

    1996-12-01

    The possibility of the segregation under solidification process using a centrifugal casting machine was investigated using an electron probe microanalyzer with elemental distribution map, line analysis and quantitative analysis. When a very small quantity of platinum was added to local molten titanium during the casting process, macroscopic segregation was observed under conditions of density difference of 0.1 g/cm3 at the most, confirming that the centrifugal force of the casting machine is extremely strong. When a Ti-6Al-4V alloy was cast, however, no macroscopic segregation was observed. The centrifugal force of the casting machine examined in the present study hardly results in the body-force segregation in this titanium alloy.

  9. 26. RW Meyer Sugar Mill: 18761889. Centrifugals, 1879, 1881. Manufacturer, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    26. RW Meyer Sugar Mill: 1876-1889. Centrifugals, 1879, 1881. Manufacturer, unknown. Supplied by Honolulu Ironworks, Honolulu, Hawaii, 1879, 1881. View: Historical view, 1934, from T. T. Waterman collection, Hawaiian Sugar Planters' Association. Once the molasses was separated from the sugar crystals it flowed through the spouts in the base of the centrifugals. The centrifugals' pulleys can be seen underneath the centrifugal. The centrifugal on the right has been reinforced with seven metal bands. The handles for the clutch mechanism are located above the centrifugal. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  10. Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

    NASA Technical Reports Server (NTRS)

    Fuller, Charles A.

    1992-01-01

    This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

  11. Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

    NASA Technical Reports Server (NTRS)

    Fuller, Charles A.

    1997-01-01

    This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

  12. Detection methods for centrifugal microfluidic platforms.

    PubMed

    Burger, Robert; Amato, Letizia; Boisen, Anja

    2016-02-15

    Centrifugal microfluidics has attracted much interest from academia as well as industry, since it potentially offers solutions for affordable, user-friendly and portable biosensing. A wide range of so-called fluidic unit operations, e.g. mixing, metering, liquid routing, and particle separation, have been developed and allow automation and integration of complex assay protocols in lab-on-a-disc systems. Besides liquid handling, the detection strategy for reading out the assay is crucial for developing a fully integrated system. In this review, we focus on biosensors and readout methods for the centrifugal microfluidics platform and cover optical as well as mechanical and electrical detection principles.

  13. Wave-Driven Rotation In Centrifugal Mirrors

    SciTech Connect

    Abraham J. Fetterman and Nathaniel J. Fisch

    2011-03-28

    Centrifugal mirrors use supersonic rotation to provide axial confinement and enhanced stability. Usually the rotation is produced using electrodes, but these electrodes have limited the rotation to the Alfven critical ionization velocity, which is too slow to be useful for fusion. Instead, the rotation could be produced using radio frequency waves. A fixed azimuthal ripple is a simple and efficient wave that could produce rotation by harnessing alpha particle energy. This is an extension of the alpha channeling effect. The alpha particle power and efficiency in a simulated devices is sufficient to produce rotation without external energy input. By eliminating the need for electrodes, this opens new opportunities for centrifugal traps.

  14. Enhancing radiolytic stability upon concentration of tritium-labeled pharmaceuticals utilizing centrifugal evaporation.

    PubMed

    Marques, Rosemary; Helmy, Roy; Waterhouse, David

    2015-05-30

    Tritium radiopharmaceuticals are often used in drug development because of their desirable specific activity. The inherent instability of these radioactive tracers often leads to a requirement to purify prior to use. Purification methodologies such as preparative chromatography and solid/liquid extractions often utilize water as a solvent, which is not suitable for long-term storage and necessitates removal. Rotary evaporation has traditionally been utilized for the removal of this unwanted solvent, however, this method has been shown to lead to decomposition of the tritium species in some cases. Centrifugal evaporation is a milder concentration method which has been demonstrated to effectively remove solvents. In this study, we show that centrifugal evaporation leads to effective concentration of tritium samples without the decomposition typically observed by rotary evaporation.

  15. Reduced-order modeling for mistuned centrifugal impellers with crack damages

    NASA Astrophysics Data System (ADS)

    Wang, Shuai; Zi, Yanyang; Li, Bing; Zhang, Chunlin; He, Zhengjia

    2014-12-01

    An efficient method for nonlinear vibration analysis of mistuned centrifugal impellers with crack damages is presented. The main objective is to investigate the effects of mistuning and cracks on the vibration features of centrifugal impellers and to explore effective techniques for crack detection. Firstly, in order to reduce the input information needed for component mode synthesis (CMS), the whole model of an impeller is obtained by rotation transformation based on the finite element model of a sector model. Then, a hybrid-interface method of CMS is employed to generate a reduced-order model (ROM) for the cracked impeller. The degrees of freedom on the crack surfaces are retained in the ROM to simulate the crack breathing effects. A novel approach for computing the inversion of large sparse matrix is proposed to save memory space during model order reduction by partitioning the matrix into many smaller blocks. Moreover, to investigate the effects of mistuning and cracks on the resonant frequencies, the bilinear frequency approximation is used to estimate the resonant frequencies of the mistuned impeller with a crack. Additionally, statistical analysis is performed using the Monte Carlo simulation to study the statistical characteristics of the resonant frequencies versus crack length at different mistuning levels. The results show that the most significant effect of mistuning and cracks on the vibration response is the shift and split of the two resonant frequencies with the same nodal diameters. Finally, potential quantitative indicators for detection of crack of centrifugal impellers are discussed.

  16. Internal flow numerical simulation of double-suction centrifugal pump using DES model

    NASA Astrophysics Data System (ADS)

    Zhou, P. J.; Wang, F. J.; Yang, M.

    2012-11-01

    It is a challenging task for the flow simulation for a double-suction centrifugal pump, because the wall effects are strong in this type of pumps. Detached-eddy simulation (DES), referred as a hybrid RANS-LES approach, has emerged recently as a potential compromise between RANS based turbulence models and Large Eddy Simulation. In this approach, the unsteady RANS model is employed in the boundary layer, while the LES treatment is applied to the separated region. In this paper, S-A DES method and SST k-ω DES method are applied to the numerical simulation for the 3D flow in whole passage of a double-suction centrifugal pump. The unsteady flow field including velocity and pressure distributions is obtained. The head and efficiency of the pump are predicted and compared with experimental results. According to the calculated results, S-A DES model is easy to control the partition of the simulation when using near wall grid with 30 < y+<300 control approach. It also has better performance on efficiency and accuracy than SST k - ω DES method. S-A DES method is more suitable for solving the unsteady flow in double-suction centrifugal pump. S-A DES method can capture more flow phenomenon than SST k - ω DES method. In addition, it can accurately predict the power performance under different flow conditions, and can reflect pressure fluctuation characteristics.

  17. Gas Chromatography.

    ERIC Educational Resources Information Center

    Cram, Stuart P.; And Others

    1980-01-01

    Selects fundamental developments in theory, methodology, and instrumentation in gas chromatography (GC). A special section reviews GC in the People's Republic of China. Over 1,000 references are cited. (CS)

  18. Concentrical coils counter-current chromatography for natural products isolation: Salvia miltiorrhiza Bunge as example.

    PubMed

    Zhang, Lihong; Wang, Yanyan; Guo, Xiuyun; Wu, Shihua

    2017-02-22

    Countercurrent chromatography (CCC) is an efficient separation technique without the solid support matrix, largely depending on the partition of two-immiscible liquid phases in the separation column. Since the helical coil planet centrifuge was invented in early 1970s by Yoichiro Ito, a series of coils columns, including spiral coils and conical coils columns have been developed for CCC separation. In this work, we introduced a new simple and efficient concentrical coils column for CCC separation, which was prepared by winding the whole polytetrafluoroethylene (PTFE) tube into the circular grooves from the rotation axis in the same direction. Once the PTFE tube filled in all space of one round of the circular groove, it was jumped into the nearby outer circular groove through the gap and until the whole groove was filled. The three same concentrical coils distributed on three disc-shaped holders were connected by the same PTFE tube to form concentrical coils separation column. The separation capacity was further investigated using ten tanshinones of the extracts of a Traditional Chinese Medicine Salvia miltiorrhiza Bunge as a model natural product. All results indicated that the concentrical coils column could hold satisfactory retention of the stationary phase, higher theoretical plate number and better resolution for CCC separation of more than ten tanshinones. It may be an alternative CCC column for non-targeted and targeted isolation of bioactive natural products.

  19. Vacuum chamber-free centrifuge with magnetic bearings.

    PubMed

    Park, Cheol Hoon; Kim, Soohyun; Kim, Kyung-Soo

    2013-09-01

    Centrifuges are devices that separate particles of different densities and sizes through the application of a centrifugal force. If a centrifuge could be operated under atmospheric conditions, all vacuum-related components such as the vacuum chamber, vacuum pump, diffusion pump, and sealing could be removed from a conventional centrifuge system. The design and manufacturing procedure for centrifuges could then be greatly simplified to facilitate the production of lightweight centrifuge systems of smaller volume. Furthermore, the maintenance costs incurred owing to wear and tear due to conventional ball bearings would be eliminated. In this study, we describe a novel vacuum chamber-free centrifuge supported by magnetic bearings. We demonstrate the feasibility of the vacuum chamber-free centrifuge by presenting experimental results that verify its high-speed support capability and motoring power capacity.

  20. Partitioning ecosystems for sustainability.

    PubMed

    Murray, Martyn G

    2016-03-01

    Decline in the abundance of renewable natural resources (RNRs) coupled with increasing demands of an expanding human population will greatly intensify competition for Earth's natural resources during this century, yet curiously, analytical approaches to the management of productive ecosystems (ecological theory of wildlife harvesting, tragedy of the commons, green economics, and bioeconomics) give only peripheral attention to the driving influence of competition on resource exploitation. Here, I apply resource competition theory (RCT) to the exploitation of RNRs and derive four general policies in support of their sustainable and equitable use: (1) regulate resource extraction technology to avoid damage to the resource base; (2) increase efficiency of resource use and reduce waste at every step in the resource supply chain and distribution network; (3) partition ecosystems with the harvesting niche as the basic organizing principle for sustainable management of natural resources by multiple users; and (4) increase negative feedback between consumer and resource to bring about long-term sustainable use. A simple policy framework demonstrates how RCT integrates with other elements of sustainability science to better manage productive ecosystems. Several problem areas of RNR management are discussed in the light of RCT, including tragedy of the commons, overharvesting, resource collapse, bycatch, single species quotas, and simplification of ecosystems.

  1. 21 CFR 864.5350 - Microsedimentation centrifuge.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology...

  2. 21 CFR 864.5350 - Microsedimentation centrifuge.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology...

  3. Research centrifuge accommodations on Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Arno, Roger D.; Horkachuk, Michael J.

    1990-01-01

    Life sciences research using plants and animals on the Space Station Freedom requires the ability to maintain live subjects in a safe and low stress environment for long durations at microgravity and at one g. The need for a centrifuge to achieve these accelerations is evident. Programmatic, technical, and cost considerations currently favor a 2.5 meter diameter centrifuge located either in the end cone of a Space Station Freedom node or in a separate module. A centrifuge facility could support a mix of rodent, plant, and small primate habitats. An automated cage extractor could be used to remove modular habitats in pairs without stopping the main rotor, minimizing the disruption to experiment protocols. The accommodation of such a centrifuge facility on the Space Station represents a significant demand on the crew time, power, data, volume, and logistics capability. It will contribute to a better understanding of the effects of space flight on humans, an understanding of plant growth in space for the eventual production of food, and an understanding of the role of gravity in biological processes.

  4. Predicting Droplet Formation on Centrifugal Microfluidic Platforms

    NASA Astrophysics Data System (ADS)

    Moebius, Jacob Alfred

    Centrifugal microfluidics is a widely known research tool for biological sample and water quality analysis. Currently, the standard equipment used for such diagnostic applications include slow, bulky machines controlled by multiple operators. These machines can be condensed into a smaller, faster benchtop sample-to-answer system. Sample processing is an important step taken to extract, isolate, and convert biological factors, such as nucleic acids or proteins, from a raw sample to an analyzable solution. Volume definition is one such step. The focus of this thesis is the development of a model predicting monodispersed droplet formation and the application of droplets as a technique for volume definition. First, a background of droplet microfluidic platforms is presented, along with current biological analysis technologies and the advantages of integrating such technologies onto microfluidic platforms. Second, background and theories of centrifugal microfluidics is given, followed by theories relevant to droplet emulsions. Third, fabrication techniques for centrifugal microfluidic designs are discussed. Finally, the development of a model for predicting droplet formation on the centrifugal microfluidic platform are presented for the rest of the thesis. Predicting droplet formation analytically based on the volumetric flow rates of the continuous and dispersed phases, the ratios of these two flow rates, and the interfacial tension between the continuous and dispersed phases presented many challenges, which will be discussed in this work. Experimental validation was completed using continuous phase solutions of different interfacial tensions. To conclude, prospective applications are discussed with expected challenges.

  5. Centrifugal Pump Experiment for Chemical Engineering Undergraduates

    ERIC Educational Resources Information Center

    Vanderslice, Nicholas; Oberto, Richard; Marrero, Thomas R.

    2012-01-01

    The purpose of this paper is to describe a Centrifugal Pump Experiment that provided an experiential learning experience to chemical engineering undergraduates at the University of Missouri in the spring of 2010 in the Unit Operations Laboratory course. Lab equipment was used by senior students with computer-based data and control technology. In…

  6. Extracting hydrocarbons from water using a centrifuge

    NASA Astrophysics Data System (ADS)

    Ryabov, A. Yu.; Ilyina, A. A.; Chuikin, A. V.; Velikov, A. A.

    2014-09-01

    An original method for the solid-phase microextraction of hydrocarbons from water using a centrifuge is proposed. Comparative results from the chromatographic elution of substances after liquid-phase and solid-phase microextraction are presented. The percentage of the extraction of substances from aqueous solutions and the minimum detection limit for aromatic and aliphatic compounds are calculated.

  7. Differential white cell count by centrifugal microfluidics.

    SciTech Connect

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    2010-07-01

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generation of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.

  8. Centrifugal blood pumps for various clinical needs.

    PubMed

    Ichikawa, Seiji; Nosé, Yukihiko

    2002-11-01

    During the past 10 years, different types of blood pumps were developed to address various clinical needs. The Nikkiso centrifugal blood pump was developed for cardiopulmonary bypass application. This blood pump has been widely used in Japan in more than 20% of the cardiopulmonary bypass procedures. The Kyocera C1E3 Gryo pump was developed for short-term circulatory assistance and extracorporeal membrane oxygenation application for up to 2 weeks. This blood pump has been clinically used for up to 28 days without any blood clot formation. Through Phase I of the Japanese government New Energy and Industrial Technology Development Organization (NEDO) program, a chronically implanted centrifugal pump for left ventricular assistance was developed. This pump has already demonstrated its effectiveness, safety, and durability as a 2 year blood pump through in vitro and in vivo experiments. Currently, it is in the process of being converted from an experimental to a clinical device. Through Phase II of the NEDO program, a permanently implantable biventricular assist centrifugal blood pump system is under development. It has demonstrated that the previously mentioned left ventricular assist device blood pump is easily converted into a right ventricular assist pump by simply adding a spacer between the pump and the actuator. This communication discusses the historical development strategies for centrifugal blood pumps and their current status for different clinical needs.

  9. 21 CFR 864.5350 - Microsedimentation centrifuge.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology...

  10. 21 CFR 864.5350 - Microsedimentation centrifuge.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology...

  11. 21 CFR 864.5350 - Microsedimentation centrifuge.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microsedimentation centrifuge. 864.5350 Section 864.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology...

  12. Evaluation of an improved centrifugal casting machine.

    PubMed

    Donovan, T E; White, L E

    1985-05-01

    A Type III gold alloy, a silver-palladium alloy, and a base metal alloy were cast in two different centrifugal casting machines. With the number of complete cast mesh squares as an indicator of castability, the Airspin casting machine produced superior castings with all three alloys. The base metal alloy produced the greatest number of complete squares with both casting machines.

  13. Pressure distribution in centrifugal dental casting.

    PubMed

    Nielsen, J P

    1978-02-01

    Equations are developed for liquid metal pressure in centrifugal dental casting, given the instantaneous rotational velocity, density, and certain dimensions of the casting machine and casting pattern. A "reference parabola" is introduced making the fluid pressure concept more understandable. A specially designed specimen demonstrates experimentally the reference parabola at freezing.

  14. Flow Pattern Characterization for a Centrifugal Impeller

    NASA Astrophysics Data System (ADS)

    Benavides, Efrén M.

    2014-08-01

    This paper proposes a model for characterizing the flow pattern of a centrifugal impeller attending to the severity of the reverse flow. The model assumes 1) a definition of an escaping particle as the one that flows in every operational point from the trailing edge towards the leading edge of the impeller blades, and 2) a characterization of flow where an operational point is said to have a theoretical flow pattern if it is not possible to establish a fully-reversed escaping particle on it. Therefore, the first part of the article is focused on defining an escaping particle for a centrifugal compressor. The model locates over the map of a centrifugal impeller the line that splits the map in two regions: the region on the right hand side, where a theoretical flow pattern can exist, and the region on the left, where a theoretical flow pattern cannot exist. Therefore, the locus of this line marks a frontier where the expected performance of the impeller cannot be sustained as high as expected. The second part of the article uses a high-performance commercial centrifugal impeller wheel for contrasting the model. A qualitative characterization of the surge line, conclusions and discussions are presented.

  15. APPLICATION ANALYSIS REPORT: RETECH PLASMA CENTRIFUGAL FURNACE

    EPA Science Inventory

    This document is an evaluation of the performance of the Retech, Inc. Plasma Centrifugal Furnace (PCF) and its applicability as a treatment for soils contaminated with organic and/or inorganic compounds. Both the technical and economic aspectsof the technology were examined. A...

  16. Mass Transfer in 12-CM Centrifugal Contactors

    SciTech Connect

    Chesna, J.C.

    2001-06-26

    One eight-stage unit (8-pack) of centrifugal contactors was tested in both extraction and stripping modes. Efficiencies approaching 100 percent were obtained in both modes. The contactors were operated successfully at a wide range of combined flow rates, including the HEF conditions. This report discusses the results of that test.

  17. 76 FR 9613 - USEC Inc. (American Centrifuge Lead Cascade Facility and American Centrifuge Plant); Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... use source and special nuclear material at the Lead Cascade at the Portsmouth Gaseous Diffusion Plant... operate a gas centrifuge uranium enrichment facility (the ACP) at the Portsmouth Gaseous Diffusion...

  18. Mechanisms of Sensorimotor Adaptation to Centrifugation

    NASA Technical Reports Server (NTRS)

    Paloski, W. H.; Wood, S. J.; Kaufman, G. D.

    1999-01-01

    We postulate that centripetal acceleration induced by centrifugation can be used as an inflight sensorimotor countermeasure to retain and/or promote appropriate crewmember responses to sustained changes in gravito-inertial force conditions. Active voluntary motion is required to promote vestibular system conditioning, and both visual and graviceptor sensory feedback are critical for evaluating internal representations of spatial orientation. The goal of our investigation is to use centrifugation to develop an analog to the conflicting visual/gravito-inertial force environment experienced during space flight, and to use voluntary head movements during centrifugation to study mechanisms of adaptation to altered gravity environments. We address the following two hypotheses: (1) Discordant canal-otolith feedback during head movements in a hypergravity tilted environment will cause a reorganization of the spatial processing required for multisensory integration and motor control, resulting in decreased postural stability upon return to normal gravity environment. (2) Adaptation to this "gravito-inertial tilt distortion" will result in a negative after-effect, and readaptation will be expressed by return of postural stability to baseline conditions. During the third year of our grant we concentrated on examining changes in balance control following 90-180 min of centrifugation at 1.4 9. We also began a control study in which we exposed subjects to 90 min of sustained roll tilt in a static (non-rotating) chair. This allowed us to examine adaptation to roll tilt without the hypergravity induced by centrifugation. To these ends, we addressed the question: Is gravity an internal calibration reference for postural control? The remainder of this report is limited to presenting preliminary findings from this study.

  19. Centrifugal Modelling of Soil Structures. Part I. Centrifugal Modelling of Slope Failures.

    DTIC Science & Technology

    1979-03-01

    centrifugal loading in multiples of earth’s gravitational acceleration Nd number of equipotential drops in a flow net Nf number of flow channels in a... straight line from point A to point B. It is valid for laminar flow , where v - discharge velocity, k - coefficient of permeability, i - hydraulic gradient...number) Soil mechanics, embankmen’: stability, sloPe Stability, centrifuge modelling, clay slopes, mine waste slltpes, sea clay, landslides, flow slides

  20. High stability design for new centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Kanki, H.; Katayama, K.; Morii, S.; Mouri, Y.; Umemura, S.; Ozawa, U.; Oda, T.

    1989-01-01

    It is essential that high-performance centrifugal compressors be free of subsynchronous vibrations. A new high-performance centrifugal compressor has been developed by applying the latest rotordynamics knowledge and design techniques: (1) To improve the system damping, a specially designed oil film seal was developed. This seal attained a damping ratio three times that of the conventional design. The oil film seal contains a special damper ring in the seal cartridge. (2) To reduce the destabilizing effect of the labyrinth seal, a special swirl canceler (anti-swirl nozzle) was applied to the balance piston seal. (3) To confirm the system damping margin, the dynamic simulation rotor model test and the full load test applied the vibration exciting test in actual load conditions.

  1. A centrifugal pump used as a turbine

    SciTech Connect

    Yap, F.U.; Lasnier, F. )

    1990-06-01

    Due to the high cost of putting up conventional turbines for micro-hydropower installations, Inversin (1986) mentioned the use of pumps being run in reverse to function as turbines. Typical performance characteristics of a centrifugal pump running as a turbine are shown in a figure. Pump/turbine maximum efficiencies tend to occur over a wide range of capacity. This study is concerned with the use of non-conventional hydro equipment, locally and readily available for small rural electricity applications. Here, the operation of a small centrifugal pump, used as a turbine and coupled with a conventional car alternator, was investigated. The article reveals a method for evaluating not only this but other small generating systems for appropriateness to the conditions of the site.

  2. Spaceborne centrifugal relays for spacecraft propulsion

    NASA Technical Reports Server (NTRS)

    Ouzidane, Malika

    1991-01-01

    Acceleration using centrifugal relays is a recently discovered method for the acceleration of spaceborne payloads to high velocity at high thrust. Centrifugal relays are moving rotors which progressively accelerate reaction mass to higher velocities. One important engineering problem consists of accurately tracking the position of the projectiles and rotors and guiding each projectile exactly onto the appropriate guide tracks on each rotor. The topics of this research are the system kinematics and dynamics and the computerized guidance system which will allow the projectile to approach each rotor with exact timing with respect to the rotor rotation period and with very small errors in lateral positions. Kinematics studies include analysis of rotor and projectile positions versus time and projectile/rotor interactions. Guidance studies include a detailed description of the tracking mechanism (interrupt of optical beams) and the aiming mechanism (electromagnetic focusing) including the design of electromagnetic deflection coils and the switching circuitry.

  3. Optimum design for LRE centrifugal pumps

    NASA Astrophysics Data System (ADS)

    Zhu, Zuchao; Zhang, Guoqian; Sun, Jiren

    1995-05-01

    We set up a mathematical model to predict low specific speed liquid rocket engine (LRE) centrifugal pump unit performance. Using the model in question, performance predictions were carried out for 10 types of LRE centrifugal pumps. Relative errors between experimental values and predicted values associated with efficiency and lift were all within 4%. Using the model in question, design optimization with efficiency as the target function was carried out on AM-7H and O pumps as well as AM-1R pumps and AM-50 pumps. Results clearly show that, with a presupposition of surety systems possessing high vapor corrosion characteristics, the efficiencies of these four types of pumps can be respectively raised 6.5%, 5.22%, 5.2%, and 4.41%.

  4. Mathematical simulation of centrifugal casting of pipes

    SciTech Connect

    Minosyan, Ya.P.; Gerasimov, V.G.; Ryadno, A.A.; Solov'yev, Yu.G.

    1983-01-01

    A mathematical description of centrifugal casting of long pipes in rapidly-rotating ingot molds is given. The effect of gravity force is neglected. A numerical solution is obtained for the solidification of a steel casting in a thermally insulated mold. The effect of the rate of metal pouring on the motion of the solidification interface is investigated. The disagreement with experimental data is less then 7 percent.

  5. Centrifugal shot blasting. Innovative technology summary report

    SciTech Connect

    Not Available

    1999-07-01

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer.

  6. Operating and maintenance guidelines for screenbowl centrifuges

    SciTech Connect

    Jahnig, W.S.R.; Bratton, R.; Luttrell, G.

    2009-01-15

    Plant dewatering circuits equipped with screenbowl centrifuges need to be well designed, properly operated, and adequately maintained to maximize the dewatering performance. The most important 'feed variables' are particle size, dry solids feed rate and slurry flow rate. The most important 'machine variables' include pool depth, rotational speed and gearbox ratio. The article discusses the effect of these parameters and offers some maintenance guidelines. The article was adapted from a paper presented at CoalPrep 2008. 6 refs., 2 figs., 2 tabs.

  7. Potential flow through centrifugal pumps and turbines

    NASA Technical Reports Server (NTRS)

    Sorensen, E

    1941-01-01

    The methods of conformal transformation up to the present have been applied to the potential flows in the rotation of solid bodies only to a limited extent. This report deals with aspects of centrifugal pumps and turbines such as: the complex potential for rotation, potential for the flow due to the blade rotation, velocities at the blade tip, comparison with "infinite number of blades," and a variable number of blades.

  8. Wave-driven Countercurrent Plasma Centrifuge

    SciTech Connect

    A.J. Fetterman and N.J. Fisch

    2009-03-20

    A method for driving rotation and a countercurrent flow in a fully ionized plasma centrifuge is described. The rotation is produced by radiofrequency waves near the cyclotron resonance. The wave energy is transferred into potential energy in a manner similar to the α channeling effect. The countercurrent flow may also be driven by radiofrequency waves. By driving both the rotation and the flow pattern using waves instead of electrodes, physical and engineering issues may be avoided.

  9. Femoral development in chronically centrifuged rats

    NASA Technical Reports Server (NTRS)

    Smith, S. D.

    1977-01-01

    Groups of 30-d-old male and female rats were centrifuged at 2.00 G (RE, Rotation Experimental), 1.05 G (RC, Rotation Control) or exposed to the noise and wind of the centrifuge at 1.00 G (EC, Earth Control) for periods of 1, 2, 4, 8, and 16 weeks. Measurements of their femurs indicated that exposure to centrifugation a) decreased femoral length in RE animals, b) increased femoral length in RC animals, c) reduced femoral diameter in RE and RC animals, d) increased L/D ratios in RC animals, e) decreased L/D ratios in RE animals, f) increased femur length/body weight in RE animals, g) decreased cortical thickness (CT) in RE animals, h) increased relative CT in RE animals, and decreased it in RC animals, i) accelerated ossification in RC femoral heads, j) thinned and distorted RE epiphyseal plates, and k) thickened condylar cartilage in RE females. The effects tended to be strongly sexually dimorphic, with females more severely affected by the stress than males.

  10. Avoid self-priming centrifugal pump

    SciTech Connect

    Reeves, G.G.

    1987-01-01

    The self-priming horizontal centrifugal pump becomes known to its operator either as a good pump or a bad pump. The latter is usually replaced by another type of pump, even though a properly specified self-priming centrifugal pump might have been a good choice. Use of the guidelines described in this article are intended to help in the purchase and installation of a good pump. Self-priming centrifugal pumps are used for removing liquids from below grade sumps or pits that may also contain solids, fibers and/or muck. Alternate pumps for this service include submersible pumps, vertical turbine pumps and positive displacement pumps. These alternate pumps do not pass solid particles as large as self-priming pumps do without damage. Positive displacement pumps are not normally cost-effective when pumping liquid at rates in excess of 500 gallons per minute in low-head applications. Vertical and submersible pumps must be removed when cleaning of the pump is required. Self-priming pumps are easily cleaned by opening the access plates without moving the pump; and they cost less than the other types.

  11. Effects of scaling on centrifugal blood pumps.

    PubMed

    Wong, Yew Wah; Chan, Weng Kong; Yu, S C M; Chua, Leok Poh

    2002-11-01

    Experimental studies on the effects of scaling on the performance of centrifugal blood pumps were conducted in a closed-loop test rig. For the prototype, eight different impellers of the same outer diameter of 25 mm were tested at 1,500, 2,000, and 2,500 revolutions per minute (rpm) using blood analog as fluid medium. This corresponds to Reynolds numbers (Re) of 25,900, 34,500, and 43,200, respectively. The results indicated that the nondimensional pump characteristic is a function of Re. This is understandable since the typical operating Re for centrifugal blood pumps is less than 100,000. Thus, the effects of scaling cannot be ignored for centrifugal blood pumps. Experiments on a 5x scaled-up model have also indicated that the scaled-up model is more efficient than the prototype model. Our results showed that in the range of Re tested, the nondimensional head versus flow curve is a function of Re to the power of approximately 0.25. It is observed that the nondimensional head versus flow is a function of diameter ratio to the power of 0.2.

  12. Research opportunities with the Centrifuge Facility

    NASA Astrophysics Data System (ADS)

    Funk, Glenn A.

    The Centrifuge Facility on Space Station Freedom will consist of a 2.5-meter diameter Centrifuge accommodating two concentric rings of habitats and providing variable g-forces between 0.01 g and 2.0 g; modular habitats providing housing and lifesupport for rats, mice, and plants; a habitat holding system providing power, water, airflow and other utilities to several modular habitats; and a life sciences glovebox, an isolated work volume accommodating simultaneous operations by at least two scientists and providing lighting, airflow, video and data access, and other experiment support functions. The centrifuge facility will enable long-duration animal and plant microgravity research not previously possible in the NASA flight research program. It will offer unprecedented opportunities for use of on-board 1-g control populations and statistically significant numbers of specimens. On orbit 1-g controls will allow separation of the effects of microgravity from other environmental factors. Its selectable-g and simultaneous multiple-g capabilities will enable studies of gravitational thresholds, the use of artificial gravity as a countermeasure to the effects of microgravity, and ready simulation of Lunar and Martian gravities.

  13. Research opportunities with the Centrifuge Facility

    NASA Technical Reports Server (NTRS)

    Funk, Glenn A.

    1992-01-01

    The Centrifuge Facility on Space Station Freedom will consist of a 2.5-meter diameter Centrifuge accommodating two concentric rings of habitats and providing variable g-forces between 0.01 g and 2.0 g; modular habitats providing housing and lifesupport for rats, mice, and plants; a habitat holding system providing power, water, airflow and other utilities to several modular habitats; and a life sciences glovebox, an isolated work volume accommodating simultaneous operations by at least two scientists and providing lighting, airflow, video and data access, and other experiment support functions. The centrifuge facility will enable long-duration animal and plant microgravity research not previously possible in the NASA flight research program. It will offer unprecedented opportunities for use of on-board 1-g control populations and statistically significant numbers of specimens. On orbit 1-g controls will allow separation of the effects of microgravity from other environmental factors. Its selectable-g and simultaneous multiple-g capabilities will enable studies of gravitational thresholds, the use of artificial gravity as a countermeasure to the effects of microgravity, and ready simulation of Lunar and Martian gravities.

  14. Shallow water model for horizontal centrifugal casting

    NASA Astrophysics Data System (ADS)

    Boháček, J.; Kharicha, A.; Ludwig, A.; Wu, M.

    2012-07-01

    A numerical model was proposed to simulate the solidification process of an outer shell of work roll made by the horizontal centrifugal casting technique. Shallow water model was adopted to solve the 2D average flow dynamics of melt spreading and the average temperature distribution inside the centrifugal casting mould by considering the centrifugal force, Coriolis force, viscous force due to zero velocity on the mould wall, gravity, and energy transport by the flow. Additionally, a 1D sub-model was implemented to consider the heat transfer in the radial direction from the solidifying shell to the mould. The solidification front was tracked by fulfilling the Stefan condition. Radiative and convective heat losses were included from both, the free liquid surface and the outer wall of the mould. Several cases were simulated with the following assumed initial conditions: constant height of the liquid metal (10, 20, and 30 mm), uniform temperature of the free liquid surface (1755 K). The simulation results have shown that while the solidification front remained rather flat, the free surface was disturbed by waves. The amplitude of waves increased with the liquid height. Free surface waves diminished as the solidification proceeded.

  15. Compact, Automated Centrifugal Slide-Staining System

    NASA Technical Reports Server (NTRS)

    Feeback, Daniel L.; Clarke, Mark S. F.

    2004-01-01

    The Directional Acceleration Vector-Driven Displacement of Fluids (DAVD-DOF) system, under development at the time of reporting the information for this article, would be a relatively compact, automated, centrifugally actuated system for staining blood smears and other microbiological samples on glass microscope slides in either a microgravitational or a normal Earth gravitational environment. The DAVD-DOF concept is a successor to the centrifuge-operated slide stainer (COSS) concept, which was reported in Slide-Staining System for Microgravity or Gravity (MSC-22949), NASA Tech Briefs, Vol. 25, No. 1 (January, 2001), page 64. The COSS includes reservoirs and a staining chamber that contains a microscope slide to which a biological sample is affixed. The staining chamber is sequentially filled with and drained of staining and related liquids from the reservoirs by use of a weighted plunger to force liquid from one reservoir to another at a constant level of hypergravity maintained in a standard swing-bucket centrifuge. In the DAVD-DOF system, a staining chamber containing a sample would also be sequentially filled and emptied, but with important differences. Instead of a simple microscope slide, one would use a special microscope slide on which would be fabricated a network of very small reservoirs and narrow channels connected to a staining chamber (see figure). Unlike in the COSS, displacement of liquid would be effected by use of the weight of the liquid itself, rather than the weight of a plunger.

  16. Green chromatography.

    PubMed

    Płotka, Justyna; Tobiszewski, Marek; Sulej, Anna Maria; Kupska, Magdalena; Górecki, Tadeusz; Namieśnik, Jacek

    2013-09-13

    Analysis of organic compounds in samples characterized by different composition of the matrix is very important in many areas. A vast majority of organic compound determinations are performed using gas or liquid chromatographic methods. It is thus very important that these methods have negligible environmental impact. Chromatographic techniques have the potential to be greener at all steps of the analysis, from sample collection and preparation to separation and final determination. The paper summarizes the approaches used to accomplish the goals of green chromatography. While complete elimination of sample preparation would be an ideal approach, it is not always practical. Solventless extraction techniques offer a very good alternative. Where solvents must be used, the focus should be on the minimization of their consumption. The approaches used to make chromatographic separations greener differ depending on the type of chromatography. In gas chromatography it is advisable to move away from using helium as the carrier gas because it is a non-renewable resource. GC separations using low thermal mass technology can be greener because of energy savings offered by this technology. In liquid chromatography the focus should be on the reduction of solvent consumption and replacement of toxic and environmentally hazardous solvents with more benign alternatives. Multidimensional separation techniques have the potential to make the analysis greener in both GC and LC. The environmental impact of the method is often determined by the location of the instrument with respect to the sample collection point.

  17. Ion Chromatography.

    ERIC Educational Resources Information Center

    Mulik, James D.; Sawicki, Eugene

    1979-01-01

    Accurate for the analysis of ions in solution, this form of analysis enables the analyst to directly assay many compounds that previously were difficult or impossible to analyze. The method is a combination of the methodologies of ion exchange, liquid chromatography, and conductimetric determination with eluant suppression. (Author/RE)

  18. Counter-current motion in counter-current chromatography.

    PubMed

    Ito, Yoichiro

    2014-12-12

    After the CCC2012 meeting, I have received an e-mail regarding the terminology of "Countercurrent Chromatography". It stated that the term "Countercurrent" is a misnomer, because its stationary phase is motionless in the column and that the method should be renamed as liquid-liquid separations or centrifugal separations. However, it was found that these names are already used for various other techniques as found via Google search. The term "Countercurrent Chromatography" was originally made after two preparative methods of Countercurrent distribution and liquid Chromatography, both having no countercurrent motion in the column. However, it is surprising to find that this F1 hybrid method "Countercurrent Chromatography" can clearly exhibit countercurrent motion within the separation column in both hydrodynamic and hydrostatic equilibrium systems. This justifies that "Countercurrent Chromatography" is a proper term for this chromatographic method.

  19. A critical evaluation of Amicon Ultra centrifugal filters for separating proteins, drugs and nanoparticles in biosamples.

    PubMed

    Johnsen, Elin; Brandtzaeg, Ole Kristian; Vehus, Tore; Roberg-Larsen, Hanne; Bogoeva, Vanya; Ademi, Ornela; Hildahl, Jon; Lundanes, Elsa; Wilson, Steven Ray

    2016-02-20

    Amicon(®) Ultra centrifugal filters were critically evaluated for various sample preparations, namely (a) proteome fractionation, (b) sample cleanup prior to liquid chromatography mass spectrometry (LC-MS) measurement of small molecules in cell lysate, and (c) separating drug-loaded nanoparticles and released drugs for accurate release profiling in biological samples. (a) Filters of supposedly differing molar mass (MM) selectivity (10, 30, 50 and 100K) were combined to attempt fractionation of samples of various complexity and concentration. However, the products had surprisingly similar MM retentate/filtrate profiles, and the filters were unsuited for proteome fractionation. (b) Centrifugal filtration was the only clean-up procedure in a FDA-guideline validated LC-MS method for determining anti-tuberculosis agents rifampicin and thioridazine in macrophage cell lysate. An additional organic solvent washing step (drug/protein-binding disruption) was required for satisfactory recovery. (c) The centrifugation filters are well suited for separating drugs and nanoparticles in simple aqueous solutions, but significantly less so for biological samples, as common drug-protein binding disruptors can dissolve NPs or be incompatible with LC-MS instrumentation.

  20. Temporal Partitioning on Multicore Platform

    NASA Astrophysics Data System (ADS)

    Mahmud Pathan, Ristat; Hashi, Feysal; Stenstrom, Per; Green, Lars-Goran; Hult, Torbjorn; Sandin, Patrik

    2014-08-01

    This paper addresses the problem of ensuring temporal partitioning according to the ARINC-653 standard for integrating multiple applications on the same multicore platform. To employ temporal partitioning, we propose the design and analysis of a hierarchical scheduling framework (HSF) for multicore platform. In HSF, each application has a server task, which is mapped to one of the physical cores of the multicore platform. The HSF framework is based on scheduling at two-levels: (i) a system-level scheduler for each core schedules the server tasks that are mapped to that core, and (ii) a task- level scheduler for each application schedules the tasks of the application. This paper presents the design and analysis of this two-level HSF that can be used to ensure temporal partitioning and meeting all the deadlines of each application tasks. The effectiveness of our technique is demonstrated using real-world space applications provided by RUAG Space Sweden AB.

  1. Investigation of partitioning mechanism for volatile organic compounds in a multiphase system.

    PubMed

    Starokozhev, Elena; Sieg, Karsten; Fries, Elke; Püttmann, Willhelm

    2011-03-01

    Laboratory experiments were performed to investigate the partitioning behavior of a set of diverse volatile organic compounds (VOCs). After equilibration at a temperature of 25°C, the VOC concentrations were measured by headspace method in combination with gas chromatography/mass spectrometry (GC/MS). The obtained data were used to determine the partition coefficients (K(P)) of VOCs in a gas-liguid-solid system. The results have shown that the presence and nature of solid materials in the working solution control the air-water partitioning of dissolved VOCs. The air/solution partitioning of BTEX and C(9)-C(10) aldehydes was most affected in the presence of diesel soot. K(P) values decreased by a factor ranging from 1.5 for toluene to 3.0 for ethylbenzene. The addition of mineral dust in the working solution exhibited greater influence on the partitioning of short aldehydes. K(P) values decreased by a factor of 1.8. The experimental partition coefficients were used to develop a predictive model for partitioning of BTEX and n-aldehydes between air, water and solid phases.

  2. Freeze-out extraction of monocarboxylic acids from water into acetonitrile under the action of centrifugal forces

    NASA Astrophysics Data System (ADS)

    Bekhterev, V. N.

    2016-10-01

    It is established that the efficiency of the freezing-out extraction of monocarboxylic acids C3-C;8 and sorbic acid from water into acetonitrile increases under the action of centrifugal forces. The linear growth of the partition coefficient in the homologous series of C2-C8 acids with an increase in molecule length, and the difference between the efficiency of extracting sorbic and hexanoic acid, are discussed using a theoretical model proposed earlier and based on the adsorption-desorption equilibrium of the partition of dissolved organic compounds between the resulting surface of ice and the liquid phase of the extract. The advantages of the proposed technique with respect to the degree of concentration over the method of low-temperature liquid-liquid extraction are explained in light of the phase diagram for the water-acetonitrile mixture.

  3. Gas chromatography.

    PubMed

    Eiceman, G A; Hill, H H; Gardea-Torresdey, J

    1998-06-15

    This review of the fundamental developments in gas chromatography (GC) includes articles published from 1996 and 1997 and an occasional citation prior to 1996. The literature was reviewed principally using CA Selects for Gas Chromatography from Chemical Abstracts Service, and some significant articles from late 1997 may be missing from the review. In addition, the online SciSearch Database (Institute for Scientific Information) capability was used to abstract review articles or books. As with the prior recent reviews, emphasis has been given to the identification and discussion of selected developments, rather than a presentation of a comprehensive literature search, now available widely through computer-based resources. During the last two years, several themes emerged from a review of the literature. Multidimensional gas chromatography has undergone transformation encompassing a broad range of activity, including attempts to establish methods using chromatographic principles rather than a totally empirical approach. Another trend noted was a comparatively large effort in chromatographic theory through modeling efforts; these presumably became resurgent with inexpensive and powerful computing tools. Finally, an impressive level of activity was noted through the themes highlighted in this review, and this was particularly true with detectors and field instruments.

  4. [Rapid centrifugation assay standarization for dengue virus isolation].

    PubMed

    Palomino, Miryam; Gutierrez, Victoria; Salas, Ramses

    2010-03-01

    The plate centrifugation assay was standardized for dengue virus isolation from serum samples. C6/36-HT cells were used determining the optimal values for centrifugation spin speed, inoculum, sera dilution, and incubation time. Then, 22 positive serum samples with viral isolation and viral strains of the four reference dengue virus serotypes were tested simultaneously by the standardized plate centrifugation method and the conventional tube culture. The isolations were typified by indirect immunofluorescent test using monoclonal antibodies. The plate centrifugation method was optimized to 200 μL of inoculum, dilution of sera 1/20, centrifugation speed at 1600 rpm/30 min, and sensitivity of 95,5% after 5 days post-inoculation. We concluded that the plate centrifugation method increased dengue virus isolation, with a significant reduction of the time of isolation for dengue virus.

  5. Understanding Partitive Division of Fractions.

    ERIC Educational Resources Information Center

    Ott, Jack M.; And Others

    1991-01-01

    Concrete experience should be a first step in the development of new abstract concepts and their symbolization. Presents concrete activities based on Hyde and Nelson's work with egg cartons and Steiner's work with money to develop students' understanding of partitive division when using fractions. (MDH)

  6. METAL PARTITIONING IN COMBUSTION PROCESSES

    EPA Science Inventory

    This article summarizes ongoing research efforts at the National Risk Management Research Laboratory of the U.S. Environmental Protection Agency examining [high temperature] metal behavior within combustion environments. The partitioning of non-volatile (Cr and Ni), semi-volatil...

  7. Laminar flow effects in the coil planet centrifuge

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1984-01-01

    The coil planet centrifuge designed by Ito employs flow of a single liquid phase, through a rotating coiled tube in a centrifugal force field, to provide a separation of particles based on sedimentation rates. Mathematical solutions are derived for the linear differential equations governing particle behavior in the coil planet centrifuge device. These solutions are then applied as the basis of a model for optimizing particle separations.

  8. Modeling Platform Dynamics and Physiological Response to Short Arm Centrifugation

    DTIC Science & Technology

    1994-03-01

    parametric design study for a small radius centrifuge revealed such a centrifuge could fit on the NASA Space Shuttle and provide artificial gravity and...the heart are modelled as variable capacitances separated by one-way valves. The pulmonic and aortic valves are also modelled as one-way valves. The...1992 June. 10. Halstead, TW; Brown, AH; Fuller, CA; Oyama, J. Artificial gravity studies and design considerations for space station centrifuges

  9. Theory and experiments on centrifuge cratering

    NASA Astrophysics Data System (ADS)

    Schmidt, R. M.; Holsapple, K. A.

    1980-01-01

    Centrifuge experimental techniques provide possibilities for laboratory simulation of ground motion and cratering effects due to explosive loadings. The results of a similarity analysis for the thermomechanical response of a continuum show that increased gravity is a necessary condition for subscale testing when identical materials for both model and prototype are being used. The general similarity requirements for this type of subscale testing are examined both theoretically and experimentally. The similarity analysis is used to derive the necessary and sufficient requirements due to the general balance and jump equations and gives relations among all the scale factors for size, density, stress, body forces, internal energy, heat supply, heat conduction, heat of detonation, and time. Additional constraints due to specific choices of material constitutive equations are evaluated separately. The class of constitutive equations that add no further requirements is identified. For this class of materials, direct simulation of large-scale cratering events at small scale on the centrifuge is possible and independent of the actual constitutive equations. For a rate-independent soil it is shown that a small experiment at gravity g and energy E is similar to a large event at 1 G but with energy equal to g3E. Consequently, experiments at 500 G with 8 grams of explosives can be used to simulate a kiloton in the field. A series of centrifuge experiments was performed to validate the derived similarity requirements and to determine the practicality of applying the technique to dry granular soils having little or no cohesion. Ten shots using Ottawa sand at various gravities confirmed reproducibility of results in the centrifuge environment, provided information on particle size effects, and demonstrated the applicability of the derived similitude requirements. These experiments used 0.5-4 grams of pentaerythritol-tetranitrate (PETN) and 1.7 grams of lead-azide explosives. They

  10. Impeller blade design method for centrifugal compressors

    NASA Technical Reports Server (NTRS)

    Jansen, W.; Kirschner, A. M.

    1974-01-01

    The design of a centrifugal impeller with blades that are aerodynamically efficient, easy to manufacture, and mechanically sound is discussed. The blade design method described here satisfies the first two criteria and with a judicious choice of certain variables will also satisfy stress considerations. The blade shape is generated by specifying surface velocity distributions and consists of straight-line elements that connect points at hub and shroud. The method may be used to design radially elemented and backward-swept blades. The background, a brief account of the theory, and a sample design are described.

  11. Autobalancing and FDIR for a space-based centrifuge prototype

    NASA Technical Reports Server (NTRS)

    Wilson, Edward; Mah, Robert W.

    2005-01-01

    This report summarizes centrifuge-related work performed at the Smart Systems Research Laboratory at NASA Ames Research Center's Computational Sciences Division from 1995 through 2003. The goal is to develop an automated system that will sense an imbalance (both static and dynamic3) in a centrifuge and issue control commands to drive counterweights to eliminate the effects of the imbalance. This autobalancing development began when the ISS centrifuge design was not yet finalized, and was designed to work with the SSRL Centrifuge laboratory prototype, constructed in 1993-1995. Significant differences between that prototype and the current International Space Station (ISS) Centrifuge design are that: the spin axis for the SSRL Centrifuge prototype can translate freely in x and y, but not wobble, whereas the ISS centrifuge spin axis has 3 translational and two rotational degrees of freedom, supported by a vibration 34. The imbalance sensors are strained gauges both in the rotor and the stator, measuring the imbalance forces, whereas the ISS centrifuge uses eddy current displacement sensors to measure the displacements resulting from imbalance. High fidelity autobalancing and FDIR systems (for both counterweights and strain gauges) are developed and tested in MATLAB simulation, for the SSRL Centrifuge configuration. Hardware implementation of the autobalancing technology was begun in 1996, but was terminated due to lack of funding. The project lay dormant until 2001-2002 when the FDIR capability was added.

  12. Effects of centrifugation on gonadal and adrenocortical steroids in rats

    NASA Technical Reports Server (NTRS)

    Kakihana, R.; Butte, J. C.

    1980-01-01

    Many endocrine systems are sensitive to external changes in the environment. Both the pituitary adrenal and pituitary gonadal systems are affected by stress including centrifugation stress. The effect of centrifugation on the pituitary gonadal and pituitary adrenocortical systems was examined by measuring the gonadal and adrenal steroids in the plasma and brain following different duration and intensity of centrifugation stress in rats. Two studies were completed and the results are presented. The second study was carried out to describe the developmental changes of brain, plasma and testicular testosterone and dihydrotestosterone in Sprague Dawley rats so that the effect of centrifugation stress on the pituitary gonadal syatem could be better evaluated in future studies.

  13. 77 FR 9273 - USEC Inc. (American Centrifuge Lead Cascade Facility and American Centrifuge Plant); Direct...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-16

    ... American Centrifuge Operating, LLC (ACO), pursuant to Sections 161(b), 161(i), 161(o) and 184 of the Atomic... that due to uncertainty, it appears that the date for completion of activities associated with the sub... be completed. IV Accordingly, pursuant to Sections 161b, 161i, 161o, and 184 of the Atomic Energy...

  14. Some trees with partition dimension three

    NASA Astrophysics Data System (ADS)

    Fredlina, Ketut Queena; Baskoro, Edy Tri

    2016-02-01

    The concept of partition dimension of a graph was introduced by Chartrand, E. Salehi and P. Zhang (1998) [2]. Let G(V, E) be a connected graph. For S ⊆ V (G) and v ∈ V (G), define the distance d(v, S) from v to S is min{d(v, x)|x ∈ S}. Let Π be an ordered partition of V (G) and Π = {S1, S2, ..., Sk }. The representation r(v|Π) of vertex v with respect to Π is (d(v, S1), d(v, S2), ..., d(v, Sk)). If the representations of all vertices are distinct, then the partition Π is called a resolving partition of G. The partition dimension of G is the minimum k such that G has a resolving partition with k partition classes. In this paper, we characterize some classes of trees with partition dimension three, namely olive trees, weeds, and centipedes.

  15. /Chromatography+RECOVERY=superresolution chromatography

    NASA Astrophysics Data System (ADS)

    Kosarev, E. L.; Muranov, K. O.

    2003-04-01

    A method for improving the resolution of the chromatographic analysis based on deriving the point-spread function of a chromatographic column, i.e., a chromatogram of an individual compound, is described. The system of two data sets, namely, a chromatogram of a substance analyzed and a point-spread function of a chromatographic column in combination with the noise statistics, makes it possible to use the RECOVERY signal-reconstruction software package described in paper by Gelfgat et al. (Comp. Phys. Commun. 74 (1993) 335). The proposed method has been tested by chromatography of bovine serum albumin using gel filtration. The resultant resolution exceeds that reached using high-performance liquid chromatography (with the cost of the instruments being lower by a factor of 15-20).

  16. Development of a 3D circular microfluidic centrifuge for the separation of mixed particles by using their different centrifuge times

    NASA Astrophysics Data System (ADS)

    Jeon, H. J.; Kim, D. I.; Kim, M. J.; Nguyen, X. D.; Park, D. H.; Go, J. S.

    2015-11-01

    This paper presents a circular microfluidic centrifuge with two inlets and two outlets to separate mixed microparticles with a specially designed sample injection hole. To separate the mixed particles, it uses a rotational flow, generated in a chamber by counter primary flows in the microchannels. The shape and sizes of the circular microfluidic centrifuge have been designed through numerical evaluation to have a large relative centrifugal force. The difference of centrifuge times of the mixed particles of 1 μm and 6 μm was determined to be 8.2 s at an inlet Reynolds number of 500 and a sample Reynolds number of 20. In the experiment, this was measured to be about 10 s. From the separation of the two polymer particles analogous to the representative sizes of platelets and red blood cells, the circular microfluidic centrifuge shows a potential to separate human blood cells size-selectively by using the difference of centrifuge times.

  17. Centrifugation of coal-derived liquids

    SciTech Connect

    Weintraub, Murray; Weiss, Milton L.; Akhtar, Sayeed

    1980-06-01

    The application of the continuous solid bowl centrifuge to the removal of solids from coal liquefaction products was investigated. The centrifuge removed from 23 to 88% of the input ash from 8 to 73% of the input organic benzene insolubles while flow rates, viscosities, and dam heights were varied. Viscosity ..mu.., effluent liquid rate Q/sub e/, and Ambler's geometric parameter ..sigma.. were graphically correlated with attained separations. The separation was relatively insensitive to the variables, as a 50-fold increase in Q/sub e//..sigma.. corresponded to a decrease in ash removal only from 84% to 60% and to a decrease in organic solids removal only from 77% to 22%. Organic solids removal was poorer and more erratic than ash removal because of the lesser density differences and greater size variability of the organics. Ancillary studies demonstrated that coal liquefaction products may behave as a Bingham Plastic fluid, and that this results in an absolute limit on the attainable solids separation. Additional studies showed that little difference in density may exist between the organic solids and liquids, and that effects of aging may threaten the validity of viscosity measurements.

  18. Some aversive characteristics of centrifugally generated gravity.

    NASA Technical Reports Server (NTRS)

    Altman, F.

    1973-01-01

    The effective weight of rats was manipulated by centrifugation. Two effective weight levels were obtained. In three escape avoidance conditions a lever press produced a change from a base level of 2.1 g to a response level of 1.1 g. In a punishment condition a response produced a change from a 1.1 g level to a 2.1 g level and in an extinction condition responses had no effect on the 2.1 g effective weight level present. All changes took 30 sec and were maintained for an additional 10 sec before a return to base level was initiated. When responses occurred closer together than the 40 sec, they delayed the return to base level by 40 sec. This 40 sec interval is referred to as response-contingent-time. The response rate and amount of response-contingent-time served as the data. The results confirmed previous data that centrifugation is aversive. The results are interpreted as indicating that the aversiveness is attributable to the increase in effective weight, and that rats can discriminate the different angular velocity-radius of rotation combinations used.

  19. Experimental Investigation of Centrifugal Compressor Stabilization Techniques

    NASA Technical Reports Server (NTRS)

    Skoch, Gary J.

    2003-01-01

    Results from a series of experiments to investigate techniques for extending the stable flow range of a centrifugal compressor are reported. The research was conducted in a high-speed centrifugal compressor at the NASA Glenn Research Center. The stabilizing effect of steadily flowing air-streams injected into the vaneless region of a vane-island diffuser through the shroud surface is described. Parametric variations of injection angle, injection flow rate, number of injectors, injector spacing, and injection versus bleed were investigated for a range of impeller speeds and tip clearances. Both the compressor discharge and an external source were used for the injection air supply. The stabilizing effect of flow obstructions created by tubes that were inserted into the diffuser vaneless space through the shroud was also investigated. Tube immersion into the vaneless space was varied in the flow obstruction experiments. Results from testing done at impeller design speed and tip clearance are presented. Surge margin improved by 1.7 points using injection air that was supplied from within the compressor. Externally supplied injection air was used to return the compressor to stable operation after being throttled into surge. The tubes, which were capped to prevent mass flux, provided 9.3 points of additional surge margin over the baseline surge margin of 11.7 points.

  20. Centrifugally Stimulated Exospheric Ion Escape at Mercury

    NASA Technical Reports Server (NTRS)

    Delcourt, Dominique; Seki, K.; Terada, N.; Moore, Thomas E.

    2012-01-01

    We investigate the transport of ions in the low-altitude magnetosphere magnetosphere of Mercury. We show that, because of small spatial scales, the centrifugal effect due to curvature of the E B drift paths can lead to significant particle energization in the parallel direction. We demonstrate that because of this effect, ions with initial speed smaller than the escape speed such as those produced via thermal desorption can overcome gravity and escape into the magnetosphere. The escape route of this low-energy exosphere originating material is largely controlled by the magnetospheric convection rate. This escape route spreads over a narrower range of altitudes when the convection rate increases. Bulk transport of low-energy planetary material thus occurs within a limited region of space once moderate magnetospheric convection is established. These results suggest that, via release of material otherwise gravitationally trapped, the E B related centrifugal acceleration is an important mechanism for the net supply of plasma to the magnetosphere of Mercury.

  1. Wave Augmented Diffusers for Centrifugal Compressors

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.; Skoch, Gary J.

    1998-01-01

    A conceptual device is introduced which would utilize unsteady wave motion to slow and turn flows in the diffuser section of a centrifugal compressor. The envisioned device would substantially reduce the size of conventional centrifugal diffusers by eliminating the relatively large ninety degree bend needed to turn the flow from the radial/tangential to the axial direction. The bend would be replaced by a wall and the flow would instead exit through a series of rotating ports located on a disk, adjacent to the diffuser hub, and fixed to the impeller shaft. The ports would generate both expansion and compression waves which would rapidly transition from the hub/shroud (axial) direction to the radial/tangential direction. The waves would in turn induce radial/tangential and axial flow. This paper presents a detailed description of the device. Simplified cycle analysis and performance results are presented which were obtained using a time accurate, quasi-one-dimensional CFD code with models for turning, port flow conditions, and losses due to wall shear stress. The results indicate that a periodic wave system can be established which yields diffuser performance comparable to a conventional diffuser. Discussion concerning feasibility, accuracy, and integration follow.

  2. Development of an implantable centrifugal blood pump.

    PubMed

    Goldstein, A H; Pacella, J J; Trumble, D R; Clark, R E

    1992-01-01

    The efficacy of centrifugal pumps for short-term (0-30 days) ventricular support has been widely reported and favorably compared with pulsatile systems. A small, durable, implantable centrifugal blood pump is being developed for medium-term use (up to 6 months). The pump is based on the Medtronic Hemadyne system that has existed in multiple forms over the past 30 years. The pump is approximately the size of a tennis ball, weighs 240 g, and is comprised of a 2.5 cm plastic impeller driven by a radially coupled brushless DC motor. In vitro hydraulic performance was recorded over a wide range of flow conditions on a mock circulatory loop. The pump generated 7 L/min flow against an afterload of 100 mmHg pressure, with a maximum power draw of 10.4 watts. Pulsatile flow was preserved when placed in conjunction with a simulated left ventricle. In vivo testing was performed in 10 healthy sheep for 10-292 hr. Heparin was used to facilitate cannulation, and no anticoagulation was administered after pump implantation. Blood chemistries reflecting hematologic, pulmonary, renal, and hepatic functions were recorded and demonstrated no adverse effects with normal pump operation. Complications were related to kinking of blood conduits and thrombus formation within the cannulae. These results are encouraging and warrant further studies to prove feasibility of this pump as a medium-term implantable ventricular assist device.

  3. How to Use Chromatography as a Science Teaching Aid.

    ERIC Educational Resources Information Center

    Ganis, Frank M.

    Presented are five procedures which permit the effective teaching of chromatography with equipment which is readily available, economical, and simple in design. The first procedure involves a study of solute partition in two immiscible solvents and of countercurrent distribution. The second illustrates the use of unidimensional ascending paper…

  4. Drop mass transfer in a microfluidic chip compared to a centrifugal contactor

    DOE PAGES

    Nemer, Martin B.; Roberts, Christine C.; Hughes, Lindsey G.; ...

    2014-06-13

    A model system was developed for enabling a multiscale understanding of centrifugal-contactor liquid–liquid extraction.The system consisted of Nd(III) + xylenol orange in the aqueous phase buffered to pH =5.5 by KHP, and dodecane + thenoyltrifluroroacetone (HTTA) + tributyphosphate (TBP) in the organic phase. Diffusion constants were measured for neodymium in both the organic and aqueous phases, and the Nd(III) partition coefficients were measured at various HTTA and TBP concentrations. A microfluidic channel was used as a high-shear model environment to observe mass-transfer on a droplet scale with xylenol orange as the aqueous-phase metal indicator; mass-transfer rates were measured quantitatively inmore » both diffusion and reaction limited regimes on the droplet scale. Lastly, the microfluidic results were comparable to observations made for the same system in a laboratory scale liquid–liquid centrifugal contactor, indicating that single drop microfluidic experiments can provide information on mass transfer in complicated flows and geometries.« less

  5. Drop mass transfer in a microfluidic chip compared to a centrifugal contactor

    SciTech Connect

    Nemer, Martin B.; Roberts, Christine C.; Hughes, Lindsey G.; Wyatt, Nicholas B.; Brooks, Carlton F.; Rao, Rekha

    2014-06-13

    A model system was developed for enabling a multiscale understanding of centrifugal-contactor liquid–liquid extraction.The system consisted of Nd(III) + xylenol orange in the aqueous phase buffered to pH =5.5 by KHP, and dodecane + thenoyltrifluroroacetone (HTTA) + tributyphosphate (TBP) in the organic phase. Diffusion constants were measured for neodymium in both the organic and aqueous phases, and the Nd(III) partition coefficients were measured at various HTTA and TBP concentrations. A microfluidic channel was used as a high-shear model environment to observe mass-transfer on a droplet scale with xylenol orange as the aqueous-phase metal indicator; mass-transfer rates were measured quantitatively in both diffusion and reaction limited regimes on the droplet scale. Lastly, the microfluidic results were comparable to observations made for the same system in a laboratory scale liquid–liquid centrifugal contactor, indicating that single drop microfluidic experiments can provide information on mass transfer in complicated flows and geometries.

  6. Power transmission mechanism equipped with fluid and centrifugal clutch

    SciTech Connect

    Tamura, K.; Takeshita, S.; Fukunaga, T.

    1986-12-30

    This patent describes a power transmission mechanism equipped with a fluid coupling, an input shaft thereof interconnected to a power source being interconnected through the fluid coupling to an output shaft, and the output shaft being interconnected to a forward-rearward changeover mechanism including a speed changer. It is characterized in that the fluid coupling includes a shell, an impeller in the shell and a centrifugal clutch means in the shell for engaging the impeller and for driving the impeller when the shell is rotated by the input shaft at a speed above idle speed and for disengaging the impeller and the driving of the impeller when the shell is rotated by the input shaft at the idle speed. A turbine is included in the shell for standing idle in the shell when the centrifugal clutch means is disengaged and for drive by the impeller when the centrifugal clutch means is engaged and for driving the output shaft. The centrifugal clutch means comprises a support member fixed to the shell, a centrifugal shoe mounted on the support member for radial movement outwardly of the support member by centrifugal force and radial movement inwardly toward the support member. It also comprises spring means for moving the shoe inwardly toward the support member when the shell is rotated at idle speed, a cylindrical casing fixed to the impeller radially outward from the shoe and having an engaging surface for engagement by the centrifugal shoe when the shell is rotated at a speed above idle speed and the centrifugal shoe is moved radially outward by centrifugal force. The forward-rearward changeover mechanism, including the speed changer, is driven by the turbine when the centrifugal clutch means is engaged with the engaging surface and standing idle when the centrifugal clutch means is disengaged from the engaging surface and the turbine is standing idle.

  7. Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Qian, Michael C.

    Gas chromatography (GC) has many applications in the analysis of food products. GC has been used for the determination of fatty acids, triglycerides, cholesterol, gases, water, alcohols, pesticides, flavor compounds, and many more. While GC has been used for other food components such as sugars, oligosaccharides, amino acids, peptides, and vitamins, these substances are more suited to analysis by high performance liquid chromatography. GC is ideally suited to the analysis of volatile substances that are thermally stable. Substances such as pesticides and flavor compounds that meet these criteria can be isolated from a food and directly injected into the GC. For compounds that are thermally unstable, too low in volatility, or yield poor chromatographic separation due to polarity, a derivatization step must be done before GC analysis. The two parts of the experiment described here include the analysis of alcohols that requires no derivatization step, and the analysis of fatty acids which requires derivatization. The experiments specify the use of capillary columns, but the first experiment includes conditions for a packed column.

  8. Partitioning sparse rectangular matrices for parallel processing

    SciTech Connect

    Kolda, T.G.

    1998-05-01

    The authors are interested in partitioning sparse rectangular matrices for parallel processing. The partitioning problem has been well-studied in the square symmetric case, but the rectangular problem has received very little attention. They will formalize the rectangular matrix partitioning problem and discuss several methods for solving it. They will extend the spectral partitioning method for symmetric matrices to the rectangular case and compare this method to three new methods -- the alternating partitioning method and two hybrid methods. The hybrid methods will be shown to be best.

  9. High Efficiency Centrifugal Compressor for Rotorcraft Applications

    NASA Technical Reports Server (NTRS)

    Medic, Gorazd; Sharma, Om P.; Jongwook, Joo; Hardin, Larry W.; McCormick, Duane C.; Cousins, William T.; Lurie, Elizabeth A.; Shabbir, Aamir; Holley, Brian M.; Van Slooten, Paul R.

    2014-01-01

    The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were

  10. Development and assessment of a miniaturised centrifugal chromatograph for reversed-phase separations in micro-channels.

    PubMed

    Penrose, Andrew; Myers, Peter; Bartle, Keith; McCrossen, Sean

    2004-08-01

    This paper describes the micro-fabrication and preliminary assessment of a miniature polydimethylsiloxane (PDMS) device for performing rapid, parallel liquid phase chromatographic separations driven by centrifugal force in microchannels. Device components include a main separating channel, into which a high performance liquid chromatography (HPLC) particulate stationary phase was packed under pressure by application of centrifugal force, in addition to solvent and sample reservoirs. Also described are methods for sealing such devices based upon partial polymerisation of PDMS. The mobile phase flow rate through a typical device was measured and several important chromatographic parameters determined from a test separation. An expression describing mobile phase flow through packed channels was also developed, based upon work on liquid flow in open micro-channels. Good agreement between predicted and measured flow rates were observed. Some predictions for potential uses of such devices and possibilities for further miniaturisation are discussed.

  11. Parameter Study of Melt Spun Polypropylene Fibers by Centrifugal Spinning

    DTIC Science & Technology

    2014-07-01

    including drawing, template synthesis, phase separation, self- assembly, and electrospinning . Most methods are only relevant on a laboratory scale...attention as an alternative to electrospinning , the most common nanofiber formation method. Fibers of low dielectric constants and insoluble polymers that...generally cannot be used in electrospinning can be produced through centrifugal spinning. The centrifugal spinning process has several key

  12. Coil planet centrifugation as a means for small particle separation

    NASA Technical Reports Server (NTRS)

    Herrmann, F. T.

    1983-01-01

    The coil planet centrifuge uses a centrifugal force field to provide separation of particles based on differences in sedimentation rates by flow through a rotating coiled tube. Three main separations are considered: (1) single phase fresh sheep and human erythrocytes, (2) single phase fixed heep and human erythrocytes, and (3) electrophoretically enhanced single phase fresh sheep and human erythrocytes.

  13. Centrifugal Barrel Finishing Of Turbine-Blade "Fir Trees"

    NASA Technical Reports Server (NTRS)

    Mandel, Johnny L.

    1990-01-01

    Modified centrifugal barrel-finishing machine imparts desired residual compressive stresses to "fir trees" of turbine blades. Centrifugal forces generate compressive stresses, which are transmitted to turbine blades through abrasive slurries in which suspended. Eliminates need for shot peening, rounding of edges and burrs caused by shot peening and, consequently, need for mass finishing operations to remove burrs. Improves surface finish of "fir trees".

  14. Bubble Eliminator Based on Centrifugal Flow

    NASA Technical Reports Server (NTRS)

    Gonda, Steve R.; Tsao, Yow-Min D.; Lee, Wenshan

    2004-01-01

    The fluid bubble eliminator (FBE) is a device that removes gas bubbles from a flowing liquid. The FBE contains no moving parts and does not require any power input beyond that needed to pump the liquid. In the FBE, the buoyant force for separating the gas from the liquid is provided by a radial pressure gradient associated with a centrifugal flow of the liquid and any entrained bubbles. A device based on a similar principle is described in Centrifugal Adsorption Cartridge System (MSC- 22863), which appears on page 48 of this issue. The FBE was originally intended for use in filtering bubbles out of a liquid flowing relatively slowly in a bioreactor system in microgravity. Versions that operate in normal Earth gravitation at greater flow speeds may also be feasible. The FBE (see figure) is constructed as a cartridge that includes two concentric cylinders with flanges at the ends. The outer cylinder is an impermeable housing; the inner cylinder comprises a gas-permeable, liquid-impermeable membrane covering a perforated inner tube. Multiple spiral disks that collectively constitute a spiral ramp are mounted in the space between the inner and outer cylinders. The liquid enters the FBE through an end flange, flows in the annular space between the cylinders, and leaves through the opposite end flange. The spiral disks channel the liquid into a spiral flow, the circumferential component of which gives rise to the desired centrifugal effect. The resulting radial pressure gradient forces the bubbles radially inward; that is, toward the inner cylinder. At the inner cylinder, the gas-permeable, liquid-impermeable membrane allows the bubbles to enter the perforated inner tube while keeping the liquid in the space between the inner and outer cylinders. The gas thus collected can be vented via an endflange connection to the inner tube. The centripetal acceleration (and thus the radial pressure gradient) is approximately proportional to the square of the flow speed and

  15. Supersonic rotation in the Maryland Centrifugal Experiment

    NASA Astrophysics Data System (ADS)

    Messer, Sarah

    The Maryland Centrifugal Experiment (MCX) has been built to study the confinement of supersonically-rotating plasmas and velocity shear stabilization of MHD instabilities. Theory predicts improved stability and confinement when a strong radial electric field is introduced into a magnetic-mirror geometry. The resulting radial currents establish a stable highly sheared plasma rotating at supersonic velocities in the azimuthal direction under the influence of J x B forces. This arrangement leads to increased confinement because the supersonic rotation creates an artificial radial gravity which draws the plasma away from the mirrors, closing the mirror loss cone. The large vφ shear stabilizes the plasma and enforces laminar flow. Based on these concepts, we have designed and constructed a machine to produce supersonically rotating highly-ionized plasmas. It typically does this by introducing a radial voltage of 7 kV in a magnetic-mirror geometry, 2 kG at the midplane and 19 kG at each mirror. MCX has completed its main construction phase and is acquiring data, here analyzed primarily in terms of a circuit model which infers plasma characteristics from the radial voltage across the plasma and the total radial current. The theory and simulations supporting the MCX centrifugal confinement scheme are presented here with the data and analysis from its first nine months of operation, including a description of basic plasma characteristics and evidence for both stability and confinement. Theory simulation, and initial experimental data all indicate that this centrifugal confinement scheme provides good stability and confinement at the temperatures and densities under study, as well as at the larger temperatures, fields, and dimensions expected for a fusion reactor. In particular, spectroscopic and circuit-model data indicate rotational velocities in MCX of up to 100 km/s, ion temperatures of approximately 30 eV, and ion densities upwards of 1020m-3. These parameters give

  16. Use of centrifugal-gravity concentration for rejection of talc and recovery improvement in base-metal flotation

    NASA Astrophysics Data System (ADS)

    Klein, Bern; Altun, Naci Emre; Ghaffari, Hassan

    2016-08-01

    The possibility of using a centrifugal-gravity concentrator to reject Mg-bearing minerals and minimize metal losses in the flotation of base metals was evaluated. Sample characterization, batch scoping tests, pilot-scale tests, and regrind-flotation tests were conducted on a Ni flotation tailings stream. Batch tests revealed that the Mg grade decreased dramatically in the concentrate products. Pilot-scale testing of a continuous centrifugal concentrator (Knelson CVD6) on the flotation tailings revealed that a concentrate with a low mass yield, low Mg content, and high Ni upgrade ratio could be achieved. Under optimum conditions, a concentrate at 6.7% mass yield was obtained with 0.85% Ni grade at 12.9% Ni recovery and with a low Mg distribution (1.7%). Size partition curves demonstrated that the CVD also operated as a size classifier, enhancing the rejection of talc fines. Overall, the CVD was capable of rejecting Mg-bearing minerals. Moreover, an opportunity exists for the novel use of centrifugal-gravity concentration for scavenging flotation tailings and/or after comminution to minimize amount of Mg-bearing minerals reporting to flotation.

  17. Centrifugal regulator for control of deployment rates of deployable elements

    NASA Technical Reports Server (NTRS)

    Vermalle, J. C.

    1980-01-01

    The requirements, design, and performance of a centrifugal regulator aimed at limiting deployment rates of deployable elements are discussed. The overall mechanism is comprised of four distinct functional parts in a machined housing: (1) the centrifugal brake device, which checks the payout of a deployment cable; (2) the reducing gear, which produces the spin rate necesary for the braking device; (3) the payout device, which allows the unwinding of the cable; and (4) the locking device, which prevents untimely unwinding. The centrifugal regulator is set into operation by a threshold tension of the cable which unlocks the mechanism and allows unwinding. The pulley of the windout device drives the centrifugal brake with the help of the reducing gear. The centrifugal force pushes aside weights that produce friction of the studs in a cylindrical housing. The mechanism behaved well at qualification temperature and vibrations.

  18. Infiltration of fibrous preform in the centrifugal force field

    SciTech Connect

    Nishida, Yoshinori; Shirayanagi, Itaru; Sakai, Yoshibumi; Tozawa, Yasuhisa

    1994-12-31

    The pressure to infiltrate molten aluminum into alumina short fiber preform was generated by centrifugal force, and the start pressure for the infiltration was measured. The fundamental equation of infiltration phenomenon was derived from the equation of the conservation of momentum of fluid flow in the porous media in the centrifugal force field. One-dimensional solution of the equation was obtained to discuss the characteristics of fluid flow in a centrifugal force field. It was made clear that centrifugal force is effective as a motive force to infiltrate molten metal into fibrous preform, the pressure distribution of molten metal in the preform is different from that predicted by D`Arcy`s law and the infiltration is enhanced by centrifugal force.

  19. Partition behaviour of alkylphenols in crude oil/brine systems under subsurface conditions

    NASA Astrophysics Data System (ADS)

    Bennett, B.; Larter, S. R.

    1997-10-01

    Partition of organic solutes between oils and water in the subsurface is an important geochemical process occurring during petroleum migration and reservoiring, during water washing, and during petroleum production. Currently no data exists on the quantitative aspects of the partition process at subsurface conditions for solutes such as phenols and aromatic hydrocarbons which are major components of both oils and waters. We have constructed an equilibration device for oils and waters based on flow injection analysis principles to measure partition coefficients of alkylphenols in crude oil/brine systems under reservoir conditions. Concentrations of C 0C 2 alkylphenols in waters and solid phase extracts of crude oils produced in the device were determined by reverse phase high performance liquid chromatography with electrochemical detection (RP-HPLC-ED), partition coefficients being measured as a function of pressure (25-340 bar), temperature (25-150°C), and water salinity (0-100,000 mg/L sodium chloride) for a variety of oils. Partition coefficients for all compounds decreased with increasing temperature, increased with water salinity and crude oil bulk NSO content, and showed little change with varying pressure. These laboratory measurements, determined under conditions close to those typically encountered in petroleum reservoirs, suggest temperature, water salinity, and crude oil bulk NSO content will have important influence on oil-water partition processes in the subsurface during migration and water washing.

  20. Development of Centrifugal Contactor with High Reliability

    SciTech Connect

    Okamura, Nobuo; Takeuchi, Masayuki; Ogino, Hideki; Kase, Takeshi; Koizumi, Tsutomu

    2007-07-01

    In Japan Atomic Energy Agency (JAEA), an innovative centrifugal contactor system has been developed for a future reprocessing plant. It was confirmed that it had a higher extraction capacity through the uranium test already. But it was necessary that it had the higher mechanical reliability to be applied in a reprocessing plant. In this study, two types of driving units that use a ball bearing or a magnetic bearing have been developed for it. It was confirmed that they had enough abilities trough endurance tests. The driving unit with ball bearing could be operated continuously for 5000 hours that was equal to a term of an annual operation. It was found that it could be operated for a year without maintenance. JAEA will continue to improve them and select more advantageous one on the basis of economy and lifetime in near future. (authors)

  1. Implantable centrifugal pump with hybrid magnetic bearings.

    PubMed

    Bearnson, G B; Olsen, D B; Khanwilkar, P S; Long, J W; Sinnott, M; Kumar, A; Allaire, P E; Baloh, M; Decker, J

    1998-01-01

    Test methods and results of in vitro assessment of a centrifugal pump with a magnetically suspended impeller are provided. In vitro blood tests have been completed with a resulting normalized milligram index of hemolysis (NmIH) of 12.4 +/- 4.1, indicating that hemolysis is not a problem. Hydraulic characterization of the system with water has shown that a nominal pumping condition of 6 L/min at 100 mmHg was met at 2,200 rpm. Maximum clinically usable cardiac output is predicted be 10 L/min. The magnetic bearing supported impeller did not contact the housing and was shown to be stable under a variety of pumping conditions. The driving motor efficiency is 75% at the nominal condition. Finally, a description of the clinical version of the pump under development is provided.

  2. Centrifugal governor for internal combustion engines

    SciTech Connect

    Ohnishi, M.

    1986-09-23

    A centrifugal governor is described for use with an internal combustion engine which consists of: a control rack for regulating the quantity of fuel to be supplied to the engine; flyweights radially displaceable in response to the rotational speed of the engine; a tension lever pivotable through an angle dependent upon the amount of radial displacement of the flyweights; an idling spring for urging the tension lever against radially outward displacement of the flyweights; a torque cam having a cam surface determining a fuel increment to be applied at the start of the engine; a sensor lever having one end engaged by the control rack, and another end adapted to engage with the cam surface of the torque cam; a cancelling spring interposed between the torque cam and the tension lever; a control lever; a floating lever interlocking with the control lever; and spring force adjusting means arranged at one end of the idling spring.

  3. A modeling study of a centrifugal compressor

    SciTech Connect

    Popovic, P.; Shapiro, H.N.

    1998-12-31

    A centrifugal compressor, which is part of a chlorofluorocarbon R-114 chiller installation, was investigated, operating with a new refrigerant, hydrofluorocarbon R-236ea, a proposed alternative to R-114. A large set of R-236ea operating data, as well as a limited amount of R-114 data, were available for this study. A relatively simple analytical compressor model was developed to describe compressor performance. The model was built upon a thorough literature search, experimental data, and some compressor design parameters. Two original empirical relations were developed, providing a new approach to the compressor modeling. The model was developed in a format that would permit it to be easily incorporated into a complete chiller simulation. The model was found to improve somewhat on the quantitative and physical aspects of a compressor model of the same format found in the literature. It was found that the compressor model is specific to the particular refrigerant.

  4. Closed continuous-flow centrifuge rotor

    DOEpatents

    Breillatt, Jr., Julian P.; Remenyik, Carl J.; Sartory, Walter K.; Thacker, Louis H.; Penland, William Z.

    1976-01-01

    A blood separation centrifuge rotor having a generally parabolic core disposed concentrically and spaced apart within a housing having a similarly shaped cavity. Blood is introduced through a central inlet and into a central passageway enlarged downwardly to decrease the velocity of the entrant blood. Septa are disposed inside the central passageway to induce rotation of the entrant blood. A separation chamber is defined between the core and the housing wherein the whole blood is separated into red cell, white cell, and plasma zones. The zones are separated by annular splitter blades disposed within the separation chamber. The separated components are continuously removed through conduits communicating through a face seal to the outside of the rotor.

  5. [Hemodynamic analysis of a centrifugal blood pump].

    PubMed

    Wang, Yang; Yang, Ming; Xu, Zihao; Zhuang, Xiaoqi; Li, Qilei; Xu, Liang

    2015-01-01

    This paper built the mathematical model of a centrifugal blood pump, which was designed by ourselves, combined it with that of the human cardiovascular system and simulated the coupling system using Matlab. Then we set up the experiment platform, linked the blood pump to mock human cardiovascular system in case of three-stage heart failure, and measured aortic pressure and flow under different speed. The comparison between experiment results and simulation results not only indicates the coupling model is correct and the blood pump works well, but also shows that with the increase of blood pump speed, the pulsation of aortic pressure and flow will be reduced, this situation will affect the structure and function of blood vessels.

  6. Numerical simulation of centrifugal casting of pipes

    NASA Astrophysics Data System (ADS)

    Kaschnitz, E.

    2012-07-01

    A numerical simulation model for the horizontal centrifugal pipe casting process was developed with the commercial simulation package Flow3D. It considers - additionally to mass, energy and momentum conservation equations and free surface tracking - the fast radial and slower horizontal movement of the mold. The iron inflow is not steady state but time dependent. Of special importance is the friction between the liquid and the mold in connection with the viscosity and turbulence of the iron. Experiments with the mold at controlled revolution speeds were carried out using a high-speed camera. From these experiments friction coefficients for the description of the interaction between mold and melt were obtained. With the simulation model, the influence of typical process parameters (e.g. melts inflow, mold movement, melt temperature, cooling media) on the wall thickness of the pipes can be studied. The comparison to results of pipes from production shows a good agreement between simulation and reality.

  7. Rotordynamic forces on centrifugal pump impellers

    NASA Technical Reports Server (NTRS)

    Franz, R.; Arndt, N.; Caughey, T. K.; Brennen, C. E.; Acosta, A. J.

    1987-01-01

    The asymmetric flow around an impeller in a volute exerts a force upon the impeller. To study the rotordynamic force on an impeller which is vibrating around its machine axis of rotation, the impeller, mounted on a dynamometer, is made to whirl in a circular orbit within the volute. The measured force is expressed as the sum of a steady radial force and an unsteady force due to the eccentric motion of the impeller. These forces were measured in separate tests on a centrifugal pump with radically increased shroud clearance, a two-dimensional impeller, and an impeller with an inducer, the impeller of the HPOTP (High Pressure Oxygen Turbopump) of the SSME (Space Shuttle Main Engine). In each case, a destabilizing force was observed over a region of positive whirl.

  8. Reciprocating flow-based centrifugal microfluidics mixer

    NASA Astrophysics Data System (ADS)

    Noroozi, Zahra; Kido, Horacio; Micic, Miodrag; Pan, Hansheng; Bartolome, Christian; Princevac, Marko; Zoval, Jim; Madou, Marc

    2009-07-01

    Proper mixing of reagents is of paramount importance for an efficient chemical reaction. While on a large scale there are many good solutions for quantitative mixing of reagents, as of today, efficient and inexpensive fluid mixing in the nanoliter and microliter volume range is still a challenge. Complete, i.e., quantitative mixing is of special importance in any small-scale analytical application because the scarcity of analytes and the low volume of the reagents demand efficient utilization of all available reaction components. In this paper we demonstrate the design and fabrication of a novel centrifugal force-based unit for fast mixing of fluids in the nanoliter to microliter volume range. The device consists of a number of chambers (including two loading chambers, one pressure chamber, and one mixing chamber) that are connected through a network of microchannels, and is made by bonding a slab of polydimethylsiloxane (PDMS) to a glass slide. The PDMS slab was cast using a SU-8 master mold fabricated by a two-level photolithography process. This microfluidic mixer exploits centrifugal force and pneumatic pressure to reciprocate the flow of fluid samples in order to minimize the amount of sample and the time of mixing. The process of mixing was monitored by utilizing the planar laser induced fluorescence (PLIF) technique. A time series of high resolution images of the mixing chamber were analyzed for the spatial distribution of light intensities as the two fluids (suspension of red fluorescent particles and water) mixed. Histograms of the fluorescent emissions within the mixing chamber during different stages of the mixing process were created to quantify the level of mixing of the mixing fluids. The results suggest that quantitative mixing was achieved in less than 3 min. This device can be employed as a stand alone mixing unit or may be integrated into a disk-based microfluidic system where, in addition to mixing, several other sample preparation steps may be

  9. Method and centrifugal apparatus for slurry testing

    SciTech Connect

    Tuzson, J.J.

    1984-04-17

    In accordance with the centrifugal erosion testing method of the invention, a material specimen is rotated with a flat surface facing the direction of rotation and a narrow stream of an abrasive particle slurry is concurrently flowed at a preselected rate in a radial direction across the flat surface, the rotating step being at sufficiently high angular velocity to urge the abrasive particles by Coriolis acceleration into a compacted mass against the flat surface and erode material therefrom by scouring type action as the particles flow radially outward. The rotating and flowing steps are continued for a sufficient preselected duration to erode material to a measurable depth, and the depth to which the flat surface is worn by the abrasive particles is measured as an indication of the erosion resistance of the specimen material. The centrifugal slurry erosion testing apparatus includes a rotatable cylindrical vessel into the interior of which the abrasive slurry is fed and a specimen holder extending radially from the vessel having a cavity for receiving the specimen and a radial slurry flow passage communicating with the interior of the vessel. One of the radial passage longitudinal walls is defined by the flat surface of the specimen. Preferably the specimen holder comprises mating semicylindrical halves one of which has a specimen-receiving cavity in its abutting surface and the other has a narrow rectangular-in-cross section groove in its abutting surface which communicates with the interior of the vessel and together with the flat surface of the specimen defines the radial slurry flow passage. The mating semicylindrical halves are enclosed by a sleeve having an annular rim disposed interiorly of the vessel to prevent radially outward movement of the specimen holder.

  10. Continuous-flow centrifugation to collect suspended sediment for chemical analysis

    USGS Publications Warehouse

    Conn, Kathleen E.; Dinicola, Richard S.; Black, Robert W.; Cox, Stephen E.; Sheibley, Richard W.; Foreman, James R.; Senter, Craig A.; Peterson, Norman T.

    2016-12-22

    Recent advances in suspended-sediment monitoring tools and surrogate technologies have greatly improved the ability to quantify suspended-sediment concentrations and to estimate daily, seasonal, and annual suspended-sediment fluxes from rivers to coastal waters. However, little is known about the chemical composition of suspended sediment, and how it may vary spatially between water bodies and temporally within a single system owing to climate, seasonality, land use, and other natural and anthropogenic drivers. Many water-quality contaminants, such as organic and inorganic chemicals, nutrients, and pathogens, preferentially partition in sediment rather than water. Suspended sediment-bound chemical concentrations may be undetected during analysis of unfiltered water samples, owing to small water sample volumes and analytical limitations. Quantification of suspended sediment‑bound chemical concentrations is needed to improve estimates of total chemical concentrations, chemical fluxes, and exposure levels of aquatic organisms and humans in receiving environments. Despite these needs, few studies or monitoring programs measure the chemical composition of suspended sediment, largely owing to the difficulty in consistently obtaining samples of sufficient quality and quantity for laboratory analysis.A field protocol is described here utilizing continuous‑flow centrifugation for the collection of suspended sediment for chemical analysis. The centrifuge used for development of this method is small, lightweight, and portable for the field applications described in this protocol. Project scoping considerations, deployment of equipment and system layout options, and results from various field and laboratory quality control experiments are described. The testing confirmed the applicability of the protocol for the determination of many inorganic and organic chemicals sorbed on suspended sediment, including metals, pesticides, polycyclic aromatic hydrocarbons, and

  11. Tropic Responses of Phycomyces Sporangiophores to Gravitational and Centrifugal Stimuli

    PubMed Central

    Dennison, David S.

    1961-01-01

    A low-speed centrifuge was used to study the tropic responses of Phycomyces sporangiophores in darkness to the stimulus of combined gravitational and centrifugal forces. If this stimulus is constant the response is a relatively slow tropic reaction, which persists for up to 12 hours. The response is accelerated by increasing the magnitude of the gravitational-centrifugal force. A wholly different tropic response, the transient response, is elicited by an abrupt change in the gravitational-centrifugal stimulus. The transient response has a duration of only about 6 min. but is characterized by a high bending speed (about 5°/min.). An analysis of the distribution of the transient response along the growing zone shows that the active phase of the response has a distribution similar to that of the light sensitivity for the light-growth and phototropic responses. Experiments in which sporangiophores are centrifuged in an inert dense fluid indicate that the sensory mechanism of the transient response is closely related to the physical deformation of the growing zone caused by the action of the gravitational-centrifugal force on the sporangiophore as a whole. However, the response to a steady gravitational-centrifugal force is most likely not connected with this deformation, but is probably triggered by the shifting of regions or particles of differing density relative to one another inside the cell. PMID:13721903

  12. Laser system with partitioned prism

    SciTech Connect

    Nettleton, J. E.; Barr, D. N.

    1985-03-26

    An array of optical frequency-sensitive elements such as diffraction gratings or interference filters are arranged in a row, and the optical path of the laser cavity can be directed to include one of these elements. A partitioned optical prism consisting of a triangular portion and one or more paralleogramatic portions are used to direct the path. Between the portions are piezoelectric elements which, when energized, expand to provide an air gap between the portions and to allow total reflection of an optical ray at the surface of the prism next to the gap.

  13. Centrifugal Casting Features/Metallurgical Characterization of Aluminum Alloys

    SciTech Connect

    Chirita, G.; Soares, D.; Cruz, D.; Silva, F. S.; Stefanescu, I.

    2008-02-15

    This paper deals with the study of centrifugal effects on aluminium castings under high G values. Most of the studies in this domain (FGMs obtained by centrifugal casting) deal with functionally graded composites reinforced with a solid phase such as silicon particles or others. However, in this study it will be shown that unreinforced aluminium alloys may be significantly influenced by the centrifugal effect and that functionally graded castings are also obtained. It has been observed that the centrifugal effect may increase in some alloys, depending on the relative position in the castings, the rupture strength by approx. 50%, and rupture strain by about 300%, as compared to the gravity casting technique. The Young's modulus may also increase by about 20%. It has also been reported that in vertical centrifugal castings there are mainly three aspects that affect the components thus obtained, namely: fluid dynamics; vibration (inherent to the system); and centrifugal force. These features have a different effect on the castings depending on the aluminium alloy. In this paper, an analysis of the most important effects of the centrifugal casting process on metallurgical features is conducted. A solidification characterization at several points along the mould will be made in order to have an accurate idea of both the fluid dynamics inside the mould during the casting and the solidification behavior in different parts of the component. These two analyses will be related to the metallurgical properties (phase distribution; SDAS; eutectic silicon content and shape, pores density and shape) along the component and mainly along the direction of the centrifugal pressure. A comparison between castings obtained by both centrifugal casting technique and gravity casting technique is made for reference (gravity casting)

  14. The American Gas Centrifuge Past, Present, and Future

    SciTech Connect

    Waters, Dean

    2004-09-15

    The art of gas centrifugation was born in 1935 at the University of Virginia when Dr. Jesse Beams demonstrated experimentally the separation of chlorine isotopes using an ultra-high speed centrifuge. Dr. Beam’s experiment initiated work that created a rich history of scientific and engineering accomplishment in the United States in the art of isotope separation and even large scale biological separation by centrifugation. The early history of the gas centrifuge development was captured in a lecture and documented by Dr. Jesse Beams in 1975. Much of Dr. Beams lecture material is used in this paper up to the year 1960. Following work by Dr. Gernot Zippe at the University of Virginia between 1958 and 1960, the US government embarked on a centrifuge development program that ultimately led to the start of construction of the Gas Centrifuge Enrichment Plant in Piketon Ohio in the late 1970’s. The government program was abandoned in 1985 after investing in the construction of two of six planned process buildings, a complete supply chain for process and centrifuge parts, and the successful manufacture and brief operation of an initial complement of production machines that would have met 15 percent of the planned capacity of the constructed process buildings. A declining market for enriched uranium, a glut of uranium enrichment capacity worldwide, and the promise of a new laser based separation process factored in the decision to stop the government program. By the late 1990’s it had become evident that gas centrifugation held the best promise to produce enriched uranium at low cost. In1999, the United States Enrichment Corporation undertook an initiative to revive the best of the American centrifuge technology that had been abandoned fourteen years earlier. This is an exciting story and one that when complete will enable the United States to maintain its domestic supply and to be highly competitive in the world market for this important energy commodity. (auth)

  15. On some trees having partition dimension four

    NASA Astrophysics Data System (ADS)

    Ida Bagus Kade Puja Arimbawa, K.; Baskoro, Edy Tri

    2016-02-01

    In 1998, G. Chartrand, E. Salehi and P. Zhang introduced the notion of partition dimension of a graph. Since then, the study of this graph parameter has received much attention. A number of results have been obtained to know the values of partition dimensions of various classes of graphs. However, for some particular classes of graphs, finding of their partition dimensions is still not completely solved, for instances a class of general tree. In this paper, we study the properties of trees having partition dimension 4. In particular, we show that, for olive trees O(n), its partition dimension is equal to 4 if and only if 8 ≤ n ≤ 17. We also characterize all centipede trees having partition dimension 4.

  16. Ocular counterrolling induced by centrifugation during orbital space flight

    NASA Technical Reports Server (NTRS)

    Moore, S. T.; Clement, G.; Raphan, T.; Cohen, B.

    2001-01-01

    During the 1998 Neurolab mission (STS-90), four astronauts were exposed to interaural centripetal accelerations (Gy centrifugation) of 0.5 g and 1 g during rotation on a centrifuge, both on Earth and during orbital space flight. Subjects were oriented either left-ear out or right-ear out, facing or back to motion. Binocular eye movements were measured in three dimensions using a video technique. On Earth, tangential centrifugation that produces 1 g of interaural linear acceleration combines with gravity to tilt the gravitoinertial acceleration (GIA) vector 45 degrees in the roll plane relative to the head vertical, generating a summed vector of 1.4 g. Before flight, this elicited mean ocular counterrolling (OCR) of 5.7 degrees. Due to the relative absence of gravity during flight, there was no linear acceleration along the dorsoventral axis of the head. As a result, during in-flight centrifugation, gravitoinertial acceleration was strictly aligned with the centripetal acceleration along the interaural axis. There was a small but significant decrease (mean 10%) in the magnitude of OCR in space (5.1 degrees). The magnitude of OCR during postflight 1 g centrifugation was not significantly different from preflight OCR (5.9 degrees). Findings were similar for 0.5 g centrifugation, but the OCR magnitude was approximately 60% of that induced by centrifugation at 1 g. OCR during pre- and postflight static tilt was not significantly different and was always less than OCR elicited by centrifugation of Earth for an equivalent interaural linear acceleration. In contrast, there was no difference between the OCR generated by in-flight centrifugation and by static tilt on Earth at equivalent interaural linear accelerations. These data support the following conclusions: (1) OCR is generated predominantly in response to interaural linear acceleration; (2) the increased OCR during centrifugation on Earth is a response to the head dorsoventral 1 g linear acceleration component, which

  17. Centrifugal pumps: which suction specific speeds are acceptable

    SciTech Connect

    Hallam, J.L.

    1982-04-01

    Suction specific speed is an important consideration when purchasing or analyzing centrifugal pumps. There is a direct correlation between this parameter, pump reliability and maintenance expenses. This article demonstrates that in a large Gulf Coast oil refinery, centrifugal pumps with a suction specific speed greater than 11,000 failed at a frequency nearly twice that of centrifugal pumps with suction specific speed less than 11,000. This study consisted primarily of hydrocarbon pumps with an average horsepower of 150 hp. Results may vary some from those found if high energy water pumps are studied. 5 refs.

  18. Centrifugal Size-Separation Sieve for Granular Materials

    NASA Technical Reports Server (NTRS)

    Walton, Otis (Inventor); Dreyer, Christopher (Inventor); Riedel, Edward (Inventor)

    2015-01-01

    A centrifugal sieve and method utilizes centrifugal force in rapidly-rotated cylindrical or conical screens as the primary body force contributing to size segregation. Within the centrifugal acceleration field, vibration and/or shearing flows are induced to facilitate size segregation and eventual separation of the fines from the coarse material. Inside a rotating cylindrical or conical screen, a separately-rotated screw auger blade can be used to transport material along the rotating cylinder or conical wall and to induce shearing in the material.

  19. 27. RW Meyer Sugar Mill: 18761889. Centrifugals, 1879, 1881. Manufacturer, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. RW Meyer Sugar Mill: 1876-1889. Centrifugals, 1879, 1881. Manufacturer, Unknown. Supplied by Honolulu Ironworks, Honolulu Hawaii, 1879, 1881. View: Historical view, 1934, from T.T. Waterman collection, Hawaiian Sugar Planters' Association. With the inner basket of the centrifugal revolving at 1200 rpm molasses flew outward from the granulated sugar, through the holes in the brass lining, and into the stationary outer basket. The molasses drained through the spout at the right and into molasses storage pits below the floor. The centrifugals were underdriven with a belt connected to the pulley beneath the basket. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  20. Increased mitogenic response in lymphocytes from chronically centrifuged mice

    NASA Technical Reports Server (NTRS)

    Mueller, Otfried; Hunzinger, E.; Cogoli, Augusto; Bechler, B.; Lee, J.; Moore, J.; Duke, J.

    1990-01-01

    The effects upon the mitogenic response of splenic lymphocytes when exposing mice to prolonged hypergravity conditions (3.5 G for 1 year) were studied. Cultures of splenic lymphocytes isolated from both centrifuged and control (1 G) animals were stimulated with Concanavalin A and the response measured using both morphological and biochemical means. Lymphocytes obtained from centrifuged mice exhibited much higher activation rates (as measured by the incorporation of H-3 thymidine) and larger cell aggregates consisting of more lymphoblasts and mitotic figures than those observed in non centrifuged control animals. Isolated splenic lymphocytes thus appear to have been conditioned by hypergravity state.

  1. Displaying multimedia environmental partitioning by triangular diagrams

    SciTech Connect

    Lee, S.C.; Mackay, D.

    1995-11-01

    It is suggested that equilateral triangular diagrams are a useful method of depicting the equilibrium partitioning of organic chemicals among the three primary environmental media of the atmosphere, the hydrosphere, and the organosphere (natural organic matter and biotic lipids and waxes). The technique is useful for grouping chemicals into classes according to their partitioning tendencies, for depicting the incremental effects of substituents such as alkyl groups and chlorine, and for showing how partitioning changes in response to changes in temperature.

  2. Simultaneous determination of 17 sulfonamides and the potentiators ormetoprim and trimethoprim in salmon muscle by liquid chromatography with tandem mass spectrometry detection.

    PubMed

    Potter, Ross A; Burns, B Garth; van de Riet, Jeffrey M; North, David H; Darvesh, Rozina

    2007-01-01

    A simple, robust method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the simultaneous determination of 17 sulfonamides [sulfanilamide (SNL), sulfacetamide (SAA), sulfaguanidine (SGD), sulfapyridine (SPY), sulfadiazine (SDZ), sulfathiazole (STZ), sulfamerazine (SMR), sulfamethoxazole (SOZ), sulfamoxole (SXL), sulfisoxazole (SXZ), sulfamethizole (SML), sulfamethazine (SMZ), sulfamethoxypyridazine (SMP), sulfamonomethoxine (SMM), sulfachloropyridazine (SCP), sulfaquinoxaline (SQX), and sulfadimethoxine (SDM)] and 2 potentiators [ormetoprim (OMP) and trimethoprim (TMP)] in fish tissue has been developed. The analytes were extracted from homogenized fish tissue with water-acetonitrile (50 + 50). The extract was clarified by centrifugation and a portion defatted with hexane. The analytes were partitioned into chloroform and evaporated to dryness. The redissolved residue was applied to a C18 reversed-phase column with a water-acetonitrile (0.1% acetic acid) gradient. All of the compounds were completely separated and detected in <10 min at 30 degrees C using LC/MS/MS. Standard curves were linear over the range of 0.02 to 5 ng injected. The limit of detection varied from 0.1 ng/g for SMZ and OMP to 0.9 ng/g for SXL and SOZ. Recoveries varied from 100% for SDM, SOZ, and SQX and 85% for SMR, OMP, and TMP to approximately 30% for SAA. Relative standard deviations for repeat analysis varied from 4% for SMZ and SCP to 23% for SAA.

  3. Chemical amplification based on fluid partitioning in an immiscible liquid

    DOEpatents

    Anderson, Brian L.; Colston, Bill W.; Elkin, Christopher J.

    2010-09-28

    A system for nucleic acid amplification of a sample comprises partitioning the sample into partitioned sections and performing PCR on the partitioned sections of the sample. Another embodiment of the invention provides a system for nucleic acid amplification and detection of a sample comprising partitioning the sample into partitioned sections, performing PCR on the partitioned sections of the sample, and detecting and analyzing the partitioned sections of the sample.

  4. Instrumentation: Ion Chromatography.

    ERIC Educational Resources Information Center

    Fritz, James S.

    1987-01-01

    Discusses the importance of ion chromatography in separating and measuring anions. The principles of ion exchange are presented, along with some applications of ion chromatography in industry. Ion chromatography systems are described, as well as ion pair and ion exclusion chromatography, column packings, detectors, and programming. (TW)

  5. The stringy instanton partition function

    NASA Astrophysics Data System (ADS)

    Bonelli, Giulio; Sciarappa, Antonio; Tanzini, Alessandro; Vasko, Petr

    2014-01-01

    We perform an exact computation of the gauged linear sigma model associated to a D1-D5 brane system on a resolved A 1 singularity. This is accomplished via supersymmetric localization on the blown-up two-sphere. We show that in the blow-down limit the partition function reduces to the Nekrasov partition function evaluating the equivariant volume of the instanton moduli space. For finite radius we obtain a tower of world-sheet instanton corrections, that we identify with the equivariant Gromov-Witten invariants of the ADHM moduli space. We show that these corrections can be encoded in a deformation of the Seiberg-Witten prepotential. From the mathematical viewpoint, the D1-D5 system under study displays a twofold nature: the D1-branes viewpoint captures the equivariant quantum cohomology of the ADHM instanton moduli space in the Givental formalism, and the D5-branes viewpoint is related to higher rank equivariant Donaldson-Thomas invariants of.

  6. Automatic analysis of D-partition

    NASA Astrophysics Data System (ADS)

    Bogaevskaya, V. G.

    2017-01-01

    The paper is dedicated to automatization of D-partition analysis. D-partition is one of the most common methods for determination of solution stability in systems with time-delayed feedback control and its dependency on values of control parameters. A transition from analytical form of D-partition to plain graph has been investigated. An algorithm of graph faces determination and calculation of count of characteristic equation roots with positive real part for appropriate area of D-partition has been developed. The algorithm keeps an information about analytical formulas for edges of faces. It allows to make further analytical research based on the results of computer analysis.

  7. Production of Biodiesel at Kinetic Limit Achieved in a Centrifugal Reactor/Separator

    SciTech Connect

    McFarlane, Joanna; Tsouris, Costas; Birdwell Jr, Joseph F; Lee, Denise L; Jennings, Hal L; Pahmer Boitrago, Amy M; Terpstra, Sarah M

    2010-01-01

    The kinetics of the transesterification of soybean oil has been investigated in a centrifugal reactor at temperatures from 45 to 80 C and pressures up to 2.6 bar using gas chromatography flame ionization detection (GC-FID) and infrared (IR) spectroscopy. The yields of product methyl esters were quantified using IR, proton Nuclear Magnetic Resonance (H1NMR), and viscosity measurements and were found to achieve 90% of the yield in 2 min; however, to meet ASTM specifications with one pass through the reactor, a 15 min residence time was needed. Performance was improved by sequential reactions, allowing separation of by-product glycerine and injection of additional small aliquots of methanol. The kinetics was modeled using a three-step mechanism of reversible reactions, which was used to predict performance at commercial scale. The mechanism correctly predicted the exponential decline in reaction rate as the concentration of the products allowed significant reverse reactions to occur.

  8. Investigation of Flow in a Centrifugal Pump

    NASA Technical Reports Server (NTRS)

    Fischer, Karl

    1946-01-01

    The investigation of the flow in a centrifugal pump indicated that the flow patterns in frictional fluid are fundamentally different from those in frictionless fluid. In particular, the dead air space adhering to the section side undoubtedly causes a reduction of the theoretically possible delivery head. The velocity distribution over a parallel circle is also subjected to a noticeable change as a result of the incomplete filling of the passages. The relative velocity on the pressure side of the vane, which for passages completely filled with active flow would differ little from zero even at comparatively lower than normal delivery volume, is increased, so that no rapid reverse flow occurs on the pressure side of the vane even for smaller delivery volume. It was established, further, that the flow ceases to be stationary for very small quantities of water. The inflow to the impeller can be regarded as radial for the operating range an question. The velocity triangles at the exit are subjected to a significant alteration in shape ae a result of the increased peripheral velocity, which may be of particular importance in the determination of the guide vane entrance angle.

  9. Centrifugal governor for internal combustion engines

    SciTech Connect

    Ohnishi, M.

    1986-08-12

    A centrifugal governor is described for use with an internal combustion engine, comprising: a control rack for regulating the quantity of fuel to be supplied to the engine; flyweights radially displaceable in response to the rotational speed of the engine; a tension lever pivotable about a stationary fulcrum in response to the radial displacement of the flyweights; a torque cam having a cam surface determining a fuel increment to be applied at the start of the engine; a sensor lever having one end engaged by the control rack and another end disposed for engagement with the cam surface of the torque cam, the sensor lever being adapted to engage with the cam surface of the torque cam when the engine is in a starting condition, to cause displacement of the control rack into a fuel increasing position for the start of the engine; and spring means interposed between the torque cam and the tension lever and urging the torque cam with a force dependent upon the angularity of the tension lever in a direction of disengaging the sensor lever from the cam surface of the torque cam; the spring means comprising first and second springs, one of the first and second springs being formed of a thermosensitive material having a smaller spring constant at a low temperature below a predetermined value, and a larger spring constant at a temperature above the predetermined value; and the first and second springs of the spring means comprising coiled springs disposed concentrically with each other.

  10. Centrifugal governor for internal combustion engines

    SciTech Connect

    Ohkoshi, M.

    1987-04-14

    This patent describes a centrifugal governor for use with an internal combustion engine, comprising: a control rack for regulating the quantity of fuel to be supplied to the engine; flyweights radially displaceable in response to the rotational speed of the engine; a tension lever pivotable through an angle dependent upon the amount of radial displacement of the flyweights; a torque cam pivotable about and relative to a fulcrum shaft thereof and having a cam surface including a cam surface portion determining a fuel increment to be applied at the start of the engine; a sensor lever having one end engaged by the control rack; the sensor lever having another end disposed to engage with the cam surface portion of the torque cam when the engine is in a starting condition, to permit displacement of the control rack into a fuel increasing position for the start of the engine; and a cancelling spring interposed between the torque cam and the tension lever and urging the torque cam with a force dependent upon the angularity of the tension lever to cause pivoting of the torque cam about the fulcrum shaft thereof in a direction of disengaging the sensor lever from the cam surface portion of the torque cam. The improvement is described comprising biasing means for forcibly pivotally displacing, immediately before operation of a starter of the engine, the torque cam in one direction against the urging force of the cancelling spring to a predetermined position.

  11. Fluid dynamic noise in a centrifugal pump

    NASA Astrophysics Data System (ADS)

    Tse, D. G.; Whitelaw, J. H.

    1993-08-01

    Pressure distributions and frequency spectra have been obtained in a centrifugal pump having flow rates between the design point and near shut-down. The pump was comprised of a radial flow impeller with four backswept blades and a single volute. Measurements were obtained at the design flow rate and at off-design conditions to advance understanding of noise generation, to quantify the contribution of tonal, narrowband and broadband components to the overall noise and to develop strategies for suppressing fluid dynamic noise by flow control and active control. Fluid dynamic noise was generated by the unsteady conditions encountered by the impeller blade. Unsteady conditions originated from non-uniformities at the inlet and the impeller outlet at design and off-design conditions. Inlet flow non-uniformity was induced by separation regions. Flow separations are inherent in turbomachinery because of growth of the boundary layer and the disturbance effect of the rotating impeller. Flow non-uniformity at the impeller outlet stemmed from inlet flow non-uniformities in the inlet, from propagation of pressure waves in a vaneless diffuser, and from scroll effects.

  12. Wave Augmented Diffuser for Centrifugal Compressor

    NASA Technical Reports Server (NTRS)

    Skoch, Gary J. (Inventor); Paxson, Daniel E. (Inventor)

    2001-01-01

    A wave augmented diffuser for a centrifugal compressor surrounds the outlet of an impeller that rotates on a drive shaft having an axis of rotation. The impeller brings flow in in an axial direction and imparts kinetic energy to the flow discharging it in radial and tangential directions. The flow is discharged into a plurality of circumferentially disposed wave chambers. The wave chambers are periodically opened and closed by a rotary valve such that the flow through the diffuser is unsteady. The valve includes a plurality of valve openings that are periodically brought into and out of fluid communication with the wave chambers. When the wave chambers are closed, a reflected compression wave moves upstream towards the diffuser bringing the flow into the wave chamber to rest. This action recovers the kinetic energy from the flow and limits any boundary layer growth. The flow is then discharged in an axial direction through an opening in the valve plate when the valve plate is rotated to an open position. The diffuser thus efficiently raises the static pressure of the fluid and discharges an axially directed flow at a radius that is predominantly below the maximum radius of the diffuser.

  13. High efficiency, variable geometry, centrifugal cryogenic pump

    SciTech Connect

    Forsha, M.D.; Nichols, K.E.; Beale, C.A.

    1994-12-31

    A centrifugal cryogenic pump has been developed which has a basic design that is rugged and reliable with variable speed and variable geometry features that achieve high pump efficiency over a wide range of head-flow conditions. The pump uses a sealless design and rolling element bearings to achieve high reliability and the ruggedness to withstand liquid-vapor slugging. The pump can meet a wide range of variable head, off-design flow requirements and maintain design point efficiency by adjusting the pump speed. The pump also has features that allow the impeller and diffuser blade heights to be adjusted. The adjustable height blades were intended to enhance the pump efficiency when it is operating at constant head, off-design flow rates. For small pumps, the adjustable height blades are not recommended. For larger pumps, they could provide off-design efficiency improvements. This pump was developed for supercritical helium service, but the design is well suited to any cryogenic application where high efficiency is required over a wide range of head-flow conditions.

  14. Central centrifugal cicatricial alopecia: challenges and solutions

    PubMed Central

    Herskovitz, Ingrid; Miteva, Mariya

    2016-01-01

    Central centrifugal cicatricial alopecia (CCCA) is the most common scarring alopecia among African American women. Data about epidemiology, etiology, genetic inheritance, and management are scarce and come from individual reports or small series. CCCA has been associated with hot combing and traumatic hair styling for years; however, studies fail to confirm it as the sole etiologic factor. It has been shown in a small series that CCCA can be inherited in an autosomal dominant fashion, with a partial penetrance and a strong modifying effect of hairstyling and sex. CCCA presents clinically as a central area of progressive irreversible hair loss that expands to the periphery. A patchy form has also been described. Dermoscopy is helpful to identify the optimal site for the biopsy, which establishes the diagnosis. Well-designed randomized controlled trials are needed to discover the optimal management. At this point, patients are advised to avoid traction and chemical treatments; topical and intralesional steroids, calcineurin inhibitors, and minoxidil can be helpful in halting the progression. PMID:27574457

  15. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    PubMed Central

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-01-01

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. This platform has great potential in both medical diagnostics and research applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing. PMID:27054764

  16. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    SciTech Connect

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-04-07

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Ultimately, this platform has great potential in both medical diagnostics and research applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.

  17. A Centrifugal Microfluidic Platform That Separates Whole Blood Samples into Multiple Removable Fractions Due to Several Discrete but Continuous Density Gradient Sections

    DOE PAGES

    Moen, Scott T.; Hatcher, Christopher L.; Singh, Anup K.

    2016-04-07

    We present a miniaturized centrifugal platform that uses density centrifugation for separation and analysis of biological components in small volume samples (~5 μL). We demonstrate the ability to enrich leukocytes for on-disk visualization via microscopy, as well as recovery of viable cells from each of the gradient partitions. In addition, we simplified the traditional Modified Wright-Giemsa staining by decreasing the time, volume, and expertise involved in the procedure. From a whole blood sample, we were able to extract 95.15% of leukocytes while excluding 99.8% of red blood cells. Ultimately, this platform has great potential in both medical diagnostics and researchmore » applications as it offers a simpler, automated, and inexpensive method for biological sample separation, analysis, and downstream culturing.« less

  18. 18. View north of Tropic Chamber Worthington centrifugal compressor and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. View north of Tropic Chamber Worthington centrifugal compressor and control panel, in machine area. - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  19. 16. View northwest of Arctic Chamber Worthington centrifugal compressor and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. View northwest of Arctic Chamber Worthington centrifugal compressor and control panel, in machine area. - Natick Research & Development Laboratories, Climatic Chambers Building, U.S. Army Natick Research, Development & Engineering Center (NRDEC), Natick, Middlesex County, MA

  20. A multiplexed immunoassay system based upon reciprocating centrifugal microfluidics

    NASA Astrophysics Data System (ADS)

    Noroozi, Zahra; Kido, Horacio; Peytavi, Régis; Nakajima-Sasaki, Rie; Jasinskas, Algimantas; Micic, Miodrag; Felgner, Philip L.; Madou, Marc J.

    2011-06-01

    A novel, centrifugal disk-based micro-total analysis system (μTAS) for low cost and high throughput semi-automated immunoassay processing was developed. A key innovation in the disposable immunoassay disk design is in a fluidic structure that enables very efficient micro-mixing based on a reciprocating mechanism in which centrifugal acceleration acting upon a liquid element first generates and stores pneumatic energy that is then released by a reduction of the centrifugal acceleration, resulting in a reversal of direction of flow of the liquid. Through an alternating sequence of high and low centrifugal acceleration, the system reciprocates the flow of liquid within the disk to maximize incubation/hybridization efficiency between antibodies and antigen macromolecules during the incubation/hybridization stage of the assay. The described reciprocating mechanism results in a reduction in processing time and reagent consumption by one order of magnitude.

  1. 3. Interior view of centrifugal pump house showing pumps and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Interior view of centrifugal pump house showing pumps and engines, looking W. - Laurel Valley Sugar Plantation, Drainage Plant, 2 Miles South of Thibodaux on State Route 308, Thibodaux, Lafourche Parish, LA

  2. 2. View of centrifugal pump house sitting at edge of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. View of centrifugal pump house sitting at edge of drainage canal, looking E. - Laurel Valley Sugar Plantation, Drainage Plant, 2 Miles South of Thibodaux on State Route 308, Thibodaux, Lafourche Parish, LA

  3. 23. TEMPORARY CENTRIFUGAL PUMP. NOTE CHAPMAN HYDRAULICOPERATED VALVE FOR LATER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. TEMPORARY CENTRIFUGAL PUMP. NOTE CHAPMAN HYDRAULIC-OPERATED VALVE FOR LATER CONNECTION OF ENGINE PUMP ENG TO DISCHARGE HEADER. - Lakeview Pumping Station, Clarendon & Montrose Avenues, Chicago, Cook County, IL

  4. Manufacture of hollow ingots using centrifugal casting machines

    NASA Astrophysics Data System (ADS)

    Pomeshchikov, A. G.; Greneva, T. S.; Baidachenko, V. I.; Berezin, V. I.

    2010-12-01

    Centrifugal machines are proposed for the foundry created at the Almalyk Mining and Smelting Factory in order to produce hollow ingots of a liquid metal made by remelting of consumable electrodes in a refractory accumulating crucible.

  5. 25. RW Meyer Sugar Mill: 18761889. Centrifugals, 1879, 1881. Manufacturer, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. RW Meyer Sugar Mill: 1876-1889. Centrifugals, 1879, 1881. Manufacturer, Unknown. Supplied by Honolulu Iron Works, Honolulu, Hawaii, 1879, 1881. View: After sugar was granulated and cooled it had to be dried and drained, completely separating the sugar crystals from the molasses. Revolving at 1200 rpm the inner basket drove the molasses outward into the stationary outer basket leaving dried sugar behind. The steam engine counter-shaft at the left was belt driven and belts running from the counter-shaft pulleys to the centrifugals' base-pulleys provided the necessary power. Part of the clutch system which moved the belt from a moving to a stationary pulley, thus turning the centrifugals on and off, is seen in Between the counter-shaft and the centrifugals. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  6. 19. LOWER OIL ROOM DIABLO POWERHOUSE: SHARPLES OIL CENTRIFUGE AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. LOWER OIL ROOM DIABLO POWERHOUSE: SHARPLES OIL CENTRIFUGE AND OIL TANK, 1989. - Skagit Power Development, Diablo Powerhouse, On Skagit River, 6.1 miles upstream from Newhalem, Newhalem, Whatcom County, WA

  7. Looking Southeast at Precipitation System, Steam Dryer and Centrifuge in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking Southeast at Precipitation System, Steam Dryer and Centrifuge in Red Room within Recycle Recovery Building - Hematite Fuel Fabrication Facility, Recycle Recovery Building, 3300 State Road P, Festus, Jefferson County, MO

  8. A multiplexed immunoassay system based upon reciprocating centrifugal microfluidics

    PubMed Central

    Noroozi, Zahra; Kido, Horacio; Peytavi, Régis; Nakajima-Sasaki, Rie; Jasinskas, Algimantas; Micic, Miodrag; Felgner, Philip L.; Madou, Marc J.

    2011-01-01

    A novel, centrifugal disk-based micro-total analysis system (μTAS) for low cost and high throughput semi-automated immunoassay processing was developed. A key innovation in the disposable immunoassay disk design is in a fluidic structure that enables very efficient micro-mixing based on a reciprocating mechanism in which centrifugal acceleration acting upon a liquid element first generates and stores pneumatic energy that is then released by a reduction of the centrifugal acceleration, resulting in a reversal of direction of flow of the liquid. Through an alternating sequence of high and low centrifugal acceleration, the system reciprocates the flow of liquid within the disk to maximize incubation/hybridization efficiency between antibodies and antigen macromolecules during the incubation/hybridization stage of the assay. The described reciprocating mechanism results in a reduction in processing time and reagent consumption by one order of magnitude. PMID:21721711

  9. TECHNOLOGY EVALUATION REPORT: RETECH'S PLASMA CENTRIFUGAL FURNACE - VOLUME I

    EPA Science Inventory

    A demonstration of the Retech, Inc. Plasma Centrifugal Furnace (PCF) was conducted under the Superfund Innovative Technology Evaluation (SITE) Program at the Department of Energy's (DOE's) Component Development and Integration Facility in Butte, Montana. The furnace uses heat gen...

  10. 14. CENTRIFUGAL FREQUENCY RELAY IN WAYSIDE CABINET, NEW HAVEN YARD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. CENTRIFUGAL FREQUENCY RELAY IN WAYSIDE CABINET, NEW HAVEN YARD - New York, New Haven & Hartford Railroad, Automatic Signalization System, Long Island Sound shoreline between Stamford & New Haven, Stamford, Fairfield County, CT

  11. 15. FRONT VIEW, DETAIL, CENTRIFUGAL FREQUENCY RELAY IN WAYSIDE CABINET, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. FRONT VIEW, DETAIL, CENTRIFUGAL FREQUENCY RELAY IN WAYSIDE CABINET, NEW HAVEN YARD - New York, New Haven & Hartford Railroad, Automatic Signalization System, Long Island Sound shoreline between Stamford & New Haven, Stamford, Fairfield County, CT

  12. 8. FLOOR 1: TENTERING GEAR FOR SOUTH STONES, CENTRIFUGAL GOVERNOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. FLOOR 1: TENTERING GEAR FOR SOUTH STONES, CENTRIFUGAL GOVERNOR MOUNTED ON STONE SPINDLE, VERY SHORT STEELYARD - Windmill at Water Mill, Montauk Highway & Halsey Lane, Water Mill, Suffolk County, NY

  13. Centrifuge Facility for the International Space Station Alpha

    NASA Technical Reports Server (NTRS)

    Johnson, Catherine C.; Hargens, Alan R.

    1994-01-01

    The Centrifuge Facility planned for the International Space Station Alpha has under-one considerable redesign over the past year, primarily because the Station is now viewed as a 10 year mission rather than a 30 year mission and because of the need to simply the design to meet budget constraints and a 2000 launch date. The basic elements of the Centrifuge Facility remain the same, i.e., a 2.5 m diameter centrifuge, a micro-g holding unit, plant and animal habitats, a glovebox and a service unit. The centrifuge will still provide the full range of artificial gravity from 0.01 a to 2 - as originally planned; however, the extractor to permit withdrawal of habitats from the centrifuge without stopping the centrifuge has been eliminated. The specimen habitats have also been simplified and are derived from other NASA programs. The Plant Research Unit being developed by the Gravitational Biology Facility will be used to house plants in the Centrifuge Facility. Although not as ambitious as the Centrifuge Facility plant habitat, it will provide much better environmental control and lighting than the current Shuttle based Plant Growth Facility. Similarly, rodents will be housed in the Advanced Animal Habitat being developed for the Shuttle program. The Centrifuge Facility and ISSA will provide the opportunity to perform repeatable, high quality science. The long duration increments available on the Station will permit multigeneration studies on both plants and animals which have not previously been possible. The Centrifuge Facility will accommodate sufficient number of specimens to permit statistically significant sampling of specimens to investigate the time course of adaptation to altered gravity environments. The centrifuge will for the first time permit investigators to use gravity itself as a tool to investigate fundamental processes, to investigate the intensity and duration of gravity to maintain normal structure and function, to separate the effects of micro-g from

  14. Centrifugal microfluidic platforms: advanced unit operations and applications.

    PubMed

    Strohmeier, O; Keller, M; Schwemmer, F; Zehnle, S; Mark, D; von Stetten, F; Zengerle, R; Paust, N

    2015-10-07

    Centrifugal microfluidics has evolved into a mature technology. Several major diagnostic companies either have products on the market or are currently evaluating centrifugal microfluidics for product development. The fields of application are widespread and include clinical chemistry, immunodiagnostics and protein analysis, cell handling, molecular diagnostics, as well as food, water, and soil analysis. Nevertheless, new fluidic functions and applications that expand the possibilities of centrifugal microfluidics are being introduced at a high pace. In this review, we first present an up-to-date comprehensive overview of centrifugal microfluidic unit operations. Then, we introduce the term "process chain" to review how these unit operations can be combined for the automation of laboratory workflows. Such aggregation of basic functionalities enables efficient fluidic design at a higher level of integration. Furthermore, we analyze how novel, ground-breaking unit operations may foster the integration of more complex applications. Among these are the storage of pneumatic energy to realize complex switching sequences or to pump liquids radially inward, as well as the complete pre-storage and release of reagents. In this context, centrifugal microfluidics provides major advantages over other microfluidic actuation principles: the pulse-free inertial liquid propulsion provided by centrifugal microfluidics allows for closed fluidic systems that are free of any interfaces to external pumps. Processed volumes are easily scalable from nanoliters to milliliters. Volume forces can be adjusted by rotation and thus, even for very small volumes, surface forces may easily be overcome in the centrifugal gravity field which enables the efficient separation of nanoliter volumes from channels, chambers or sensor matrixes as well as the removal of any disturbing bubbles. In summary, centrifugal microfluidics takes advantage of a comprehensive set of fluidic unit operations such as

  15. Preferred orientation of BSCCO via centrifugal slip casting

    SciTech Connect

    Steinlage, G.; Roeder, R.; Trumble, K.; Bowman, K. ); Li, S.; McElfresh, M. )

    1994-04-01

    Due to the highly anisotropic properties of BSCCO superconductors, the bulk properties of these materials can be greatly affected by preferential orientation. Substantial [ital c]-axis orientation normal to the desired direction of current flow has been demonstrated by centrifugally slip casting lead-doped BSCCO-2223. The strong preferred orientation developed in the centrifugally slip-cast material demonstrates high critical current potential.

  16. AM(VI) partitioning studies. FY14 final report

    SciTech Connect

    Mincher, Bruce J.

    2014-10-01

    The use of higher oxidation states of americium in partitioning from the lanthanides is under continued investigation by the sigma team. This is based on the hypothesis that Am(VI) can be produced and remain stable in irradiated first cycle raffinate solution long enough to perform solvent extraction for separations. The stability of Am(VI) to autoreduction was measured using millimolar americium concentrations in a 1-cm cell with a Cary 6000 UV/Vis spectrophotometer for data acquisition. At millimolar americium concentrations, Am(VI) is stable enough against its own autoreduction for separations purposes. A second major accomplishment during FY14 was the hot test. Americium oxidation and extraction was performed using a centrifugal contactor-based test bed consisting of an extraction stage and two stripping stages. Sixty-three percent americium extraction was obtained in one extraction stage, in agreement with batch contacts. Promising electrochemical oxidation results have also been obtained, using terpyridine ligand derivatized electrodes for binding of Am(III). Approximately 50 % of the Am(III) was oxidized to Am(V) over the course of 1 hour. It is believed that this is the first demonstration of the electrolytic oxidation of americium in a non-complexing solution. Finally, an initial investigation of Am(VI) extraction using diethylhexylbutyramide (DEHBA) was performed.

  17. Synchronization of Mammalian Cells and Nuclei by Centrifugal Elutriation.

    PubMed

    Banfalvi, Gaspar

    2017-01-01

    Synchronized populations of large numbers of cells can be obtained by centrifugal elutriation on the basis of sedimentation properties of small round particles, with minimal perturbation of cellular functions. The physical characteristics of cell size and sedimentation velocity are operative in the technique of centrifugal elutriation also known as counterstreaming centrifugation. The elutriator is an advanced device for increasing the sedimentation rate to yield enhanced resolution of cell separation. A random population of cells is introduced into the elutriation chamber of an elutriator rotor running in a specially designed centrifuge. By increasing step-by-step the flow rate of the elutriation fluid, successive populations of relatively homogeneous cell size can be removed from the elutriation chamber and used as synchronized subpopulations. For cell synchronization by centrifugal elutriation, early log S phase cell populations are most suitable where most of the cells are in G1 and S phase (>80 %). Apoptotic cells can be found in the early elutriation fractions belonging to the sub-Go window. Protocols for the synchronization of nuclei of murine pre-B cells and high-resolution centrifugal elutriation of CHO cells are given. The verification of purity and cell cycle positions of cells in elutriated fractions includes the measurement of DNA synthesis by [(3)H]-thymidine incorporation and DNA content by propidium iodide flow cytometry.

  18. Improved g-level calculations for coil planet centrifuges.

    PubMed

    van den Heuvel, Remco N A M; König, Carola S

    2011-09-09

    Calculation of the g-level is often used to compare CCC centrifuges, either against each other or to allow for comparison with other centrifugal techniques. This study shows the limitations of calculating the g-level in the traditional way. Traditional g-level calculations produce a constant value which does not accurately reflect the dynamics of the coil planet centrifuge. This work has led to a new equation which can be used to determine the improved non-dimensional values. The new equations describe the fluctuating radial and tangential g-level associated with CCC centrifuges and the mean radial g-level value. The latter has been found to be significantly different than that determined by the traditional equation. This new equation will give a better understanding of forces experienced by sample components and allows for more accurate comparison between centrifuges. Although the new equation is far better than the traditional equation for comparing different types of centrifuges, other factors such as the mixing regime may need to be considered to improve the comparison further.

  19. Optimizing the separation performance of a gas centrifuge

    NASA Astrophysics Data System (ADS)

    Wood, H. G.

    1997-11-01

    Gas centrifuges were originally developed for the enrichment of U^235 from naturally occurring uranium for the purpose of providing fuel for nuclear power reactors and material for nuclear weapons. This required the separation of a binary mixture composed of U^235 and U^238. Since the end of the cold war, a surplus of enriched uranium exists on the world market, but many centrifuge plants exist in numerous countries. These circumstances together with the growing demand for stable isotopes for chemical and physical research and in medical science has led to the exploration of alternate applications of gas centrifuge technology. In order to acieve these multi-component separations, existing centrifuges must be modified or new centrifuges must be designed. In either case, it is important to have models of the internal flow fields to predict the separation performance and algorithms to seek the optimal operating conditions of the centrifuges. Here, we use the Onsager pancake model of the internal flow field, and we present an optimization strategy which exploits a similarity parameter in the pancake model. Numerical examples will be presented.

  20. The slide centrifuge gram stain as a urine screening method.

    PubMed

    Olson, M L; Shanholtzer, C J; Willard, K E; Peterson, L R

    1991-10-01

    A slide centrifuge Gram stain procedure was performed to screen for bacteriuria 4161 urine specimens submitted in urine preservative tubes for routine culture. For slide centrifuge Gram staining, each urine sample was mixed well. Thereafter, 0.2 mL of each sample was placed, using a pipette, into a slide centrifuge chamber and centrifuged at 2,000 rpm for 5 minutes. The slides were heat fixed, Gram stained, and read by laboratory personnel who scanned 12 consecutive oil-immersion fields using a set pattern. The presence of the same organism in six or more fields was defined as a positive urine screen. Urine samples were cultured using a 0.001-mL loop and a comparison of culture growth with slide centrifuge screening was made. When growth of 100,000 or more colony-forming units per milliliter (CFU/mL) was the reference for comparison, the screen had a sensitivity rate of 98%, a specificity rate of 90%, a negative predictive value of 99%, and a positive predictive value of 65%. When a lower colony count of 10,000 or more CFU/mL was the reference for comparison, the screen had a sensitivity rate of 88%, a specificity rate of 95%, a negative predictive value of 96%, and a positive predictive value of 84%. The slide centrifuge Gram stain is a very sensitive screening method to detect bacteriuria in an adult male population.

  1. Chromatography with two mobile phases.

    PubMed

    Wang, M; Hou, S; Parcher, J F

    2006-02-15

    Experimental results for the investigation of chromatographic columns containing two mobile phases are presented. The eluent was composed of mixtures of methanol and carbon dioxide. The column was an uncoated fused-silica-lined stainless steel capillary column. At certain experimental conditions, the eluent divided into two phases, both of which moved through the column. The predominant component of the liquid phase was methanol whereas the gas phase was composed of at least 93 mol % CO2. The columns were studied over a range of feed compositions (45-95 mol % CO2), pressures (61-101 bar), and temperatures (30-100 degrees C). The compositions and densities of each phase were calculated from the Peng-Robinson equation of state. The residence times of the two mobile phases were determined by tracer pulse chromatography. The partition coefficients of a probe solute, benzene, were measured along with the retention times of neon and the total volume of the chromatographic column as a function of temperature, pressure, and stoichiometric feed composition. The calculated column volumes, that is the volume of the liquid and gas, were constant over the full range of feed composition. The partition coefficient of benzene was constant at fixed pressure and temperature, varied logarithmically with density at fixed temperature and feed composition, and displayed a maximum at intermediate temperatures at fixed pressure and feed composition. The measured retention times of neon were consistently equivalent to the calculated residence times of the gas phase, indicating that neon did not dissolve in the liquid phase and could thus serve as an accurate dead time marker. The implementation of chromatography with two mobile phases produces a chromatographic "window". There is a lower limit for the retention volume of all solutes, viz., the residence time of the gas phase, exactly the same as normal chromatography. However, elimination of the stationary phase produces an upper limit to

  2. Ionic partitioning and stomatal regulation

    PubMed Central

    Sanoubar, Rabab; Orsini, Francesco; Gianquinto, Giorgio Prosdocimi

    2013-01-01

    Vegetable grafting is commonly claimed to improve crop’s tolerance to biotic and abiotic stresses, including salinity. Although the use of inter-specific graftings is relatively common, whether the improved salt tolerance should be attributed to the genotypic background rather than the grafting per se is a matter of discussion among scientists. It is clear that most of published research has to date overlooked the issue, with the mutual presence of self-grafted and non-grafted controls resulting to be quite rare within experimental evidences. It was recently demonstrated that the genotype of the rootstock and grafting per se are responsible respectively for the differential ion accumulation and partitioning as well as to the stomatal adaptation to the stress. The present paper contributes to the ongoing discussion with further data on the differences associated to salinity response in a range of grafted melon combinations. PMID:24309549

  3. Assimilate partitioning during reproductive growth

    SciTech Connect

    Finazzo, S.F.; Davenport, T.L.

    1987-04-01

    Leaves having various phyllotactic relationships to fruitlets were labeled for 1 hour with 10/sub r/Ci of /sup 14/CO/sub 2/. Fruitlets were also labeled. Fruitlets did fix /sup 14/CO/sub 2/. Translocation of radioactivity from the peel into the fruit occurred slowly and to a limited extent. No evidence of translocation out of the fruitlets was observed. Assimilate partitioning in avocado was strongly influenced by phyllotaxy. If a fruit and the labeled leaf had the same phyllotaxy then greater than 95% of the radiolabel was present in this fruit. When the fruit did not have the same phyllotaxy as the labeled leaf, the radiolabel distribution was skewed with 70% of the label going to a single adjacent position. Avocado fruitlets exhibit uniform labeling throughout a particular tissue. In avocado, assimilates preferentially move from leaves to fruits with the same phyllotaxy.

  4. MULTIVARIATE KERNEL PARTITION PROCESS MIXTURES

    PubMed Central

    Dunson, David B.

    2013-01-01

    Mixtures provide a useful approach for relaxing parametric assumptions. Discrete mixture models induce clusters, typically with the same cluster allocation for each parameter in multivariate cases. As a more flexible approach that facilitates sparse nonparametric modeling of multivariate random effects distributions, this article proposes a kernel partition process (KPP) in which the cluster allocation varies for different parameters. The KPP is shown to be the driving measure for a multivariate ordered Chinese restaurant process that induces a highly-flexible dependence structure in local clustering. This structure allows the relative locations of the random effects to inform the clustering process, with spatially-proximal random effects likely to be assigned the same cluster index. An exact block Gibbs sampler is developed for posterior computation, avoiding truncation of the infinite measure. The methods are applied to hormone curve data, and a dependent KPP is proposed for classification from functional predictors. PMID:24478563

  5. HPAM: Hirshfeld partitioned atomic multipoles

    NASA Astrophysics Data System (ADS)

    Elking, Dennis M.; Perera, Lalith; Pedersen, Lee G.

    2012-02-01

    An implementation of the Hirshfeld (HD) and Hirshfeld-Iterated (HD-I) atomic charge density partitioning schemes is described. Atomic charges and atomic multipoles are calculated from the HD and HD-I atomic charge densities for arbitrary atomic multipole rank l on molecules of arbitrary shape and size. The HD and HD-I atomic charges/multipoles are tested by comparing molecular multipole moments and the electrostatic potential (ESP) surrounding a molecule with their reference ab initio values. In general, the HD-I atomic charges/multipoles are found to better reproduce ab initio electrostatic properties over HD atomic charges/multipoles. A systematic increase in precision for reproducing ab initio electrostatic properties is demonstrated by increasing the atomic multipole rank from l=0 (atomic charges) to l=4 (atomic hexadecapoles). Both HD and HD-I atomic multipoles up to rank l are shown to exactly reproduce ab initio molecular multipole moments of rank L for L⩽l. In addition, molecular dipole moments calculated by HD, HD-I, and ChelpG atomic charges only ( l=0) are compared with reference ab initio values. Significant errors in reproducing ab initio molecular dipole moments are found if only HD or HD-I atomic charges used. Program summaryProgram title: HPAM Catalogue identifier: AEKP_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEKP_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GNU General Public License v2 No. of lines in distributed program, including test data, etc.: 500 809 No. of bytes in distributed program, including test data, etc.: 13 424 494 Distribution format: tar.gz Programming language: C Computer: Any Operating system: Linux RAM: Typically, a few hundred megabytes Classification: 16.13 External routines: The program requires 'formatted checkpoint' files obtained from the Gaussian 03 or Gaussian 09 quantum chemistry program. Nature of problem: An ab initio

  6. [On the partition of acupuncture academic schools].

    PubMed

    Yang, Pengyan; Luo, Xi; Xia, Youbing

    2016-05-01

    Nowadays extensive attention has been paid on the research of acupuncture academic schools, however, a widely accepted method of partition of acupuncture academic schools is still in need. In this paper, the methods of partition of acupuncture academic schools in the history have been arranged, and three typical methods of"partition of five schools" "partition of eighteen schools" and "two-stage based partition" are summarized. After adeep analysis on the disadvantages and advantages of these three methods, a new method of partition of acupuncture academic schools that is called "three-stage based partition" is proposed. In this method, after the overall acupuncture academic schools are divided into an ancient stage, a modern stage and a contemporary stage, each schoolis divided into its sub-school category. It is believed that this method of partition can remedy the weaknesses ofcurrent methods, but also explore a new model of inheritance and development under a different aspect through thedifferentiation and interaction of acupuncture academic schools at three stages.

  7. Continuous Graph Partitioning for Camera Network Surveillance

    DTIC Science & Technology

    2012-07-23

    Symmetric Gossip partitioning algorithm The distributed algorithm presented in this section assumes a symmetric gossip -type communication protocol . In... gossip communication. We prove convergence of all these algorithms, and we analyze their performance in a simulation study. 2 Continuous Partitions of...section assumes an asymmetric broadcast communication protocol . In particular, at each iteration only one camera updates its state by using local

  8. Building Ecology and Partition Design. Technical Bulletin.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, Baltimore.

    This bulletin is intended as a resource for school system facility planners and architects who design schools. Ways in which decision makers can incorporate environmental concerns in the design of school buildings are detailed. Focus is on the design of interior partition systems. Partition systems in schools serve several purposes; they define…

  9. Graph Partitioning Models for Parallel Computing

    SciTech Connect

    Hendrickson, B.; Kolda, T.G.

    1999-03-02

    Calculations can naturally be described as graphs in which vertices represent computation and edges reflect data dependencies. By partitioning the vertices of a graph, the calculation can be divided among processors of a parallel computer. However, the standard methodology for graph partitioning minimizes the wrong metric and lacks expressibility. We survey several recently proposed alternatives and discuss their relative merits.

  10. Purification of biomaterials by phase partitioning

    NASA Technical Reports Server (NTRS)

    Harris, J. M.

    1984-01-01

    A technique which is particularly suited to microgravity environments and which is potentially more powerful than electrophoresis is phase partitioning. Phase partitioning is purification by partitioning between the two immiscible aqueous layers formed by solution of the polymers poly(ethylene glycol) and dextran in water. This technique proved to be very useful for separations in one-g but is limited for cells because the cells are more dense than the phase solutions thus tend to sediment to the bottom of the container before reaching equilibrium with the preferred phase. There are three phases to work in this area: synthesis of new polymers for affinity phase partitioning; development of automated apparatus for ground-based separations; and design of apparatus for performing simple phase partitioning space experiments, including examination of mechanisms for separating phases in the absence of gravity.

  11. Cell partition in two phase polymer systems

    NASA Technical Reports Server (NTRS)

    Brooks, D. E.

    1979-01-01

    Aqueous phase-separated polymer solutions can be used as support media for the partition of biological macromolecules, organelles and cells. Cell separations using the technique have proven to be extremely sensitive to cell surface properties but application of the systems are limited to cells or aggregates which do not significantly while the phases are settling. Partition in zero g in principle removes this limitation but an external driving force must be applied to induce the phases to separate since their density difference disappears. We have recently shown that an applied electric field can supply the necessary driving force. We are proposing to utilize the NASA FES to study field-driven phase separation and cell partition on the ground and in zero g to help define the separation/partition process, with the ultimate goal being to develop partition as a zero g cell separation technique.

  12. Parallel hypergraph partitioning for scientific computing.

    SciTech Connect

    Heaphy, Robert; Devine, Karen Dragon; Catalyurek, Umit; Bisseling, Robert; Hendrickson, Bruce Alan; Boman, Erik Gunnar

    2005-07-01

    Graph partitioning is often used for load balancing in parallel computing, but it is known that hypergraph partitioning has several advantages. First, hypergraphs more accurately model communication volume, and second, they are more expressive and can better represent nonsymmetric problems. Hypergraph partitioning is particularly suited to parallel sparse matrix-vector multiplication, a common kernel in scientific computing. We present a parallel software package for hypergraph (and sparse matrix) partitioning developed at Sandia National Labs. The algorithm is a variation on multilevel partitioning. Our parallel implementation is novel in that it uses a two-dimensional data distribution among processors. We present empirical results that show our parallel implementation achieves good speedup on several large problems (up to 33 million nonzeros) with up to 64 processors on a Linux cluster.

  13. Efficient multiple-way graph partitioning algorithms

    SciTech Connect

    Dasdan, A.; Aykanat, C.

    1995-12-01

    Graph partitioning deals with evenly dividing a graph into two or more parts such that the total weight of edges interconnecting these parts, i.e., cutsize, is minimized. Graph partitioning has important applications in VLSI layout, mapping, and sparse Gaussian elimination. Since graph partitioning problem is NP-hard, we should resort to polynomial-time algorithms to obtain a good solution, or hopefully a near-optimal solution. Kernighan-Lin (KL) propsoed a 2-way partitioning algorithms. Fiduccia-Mattheyses (FM) introduced a faster version of KL algorithm. Sanchis (FMS) generalized FM algorithm to a multiple-way partitioning algorithm. Simulated Annealing (SA) is one of the most successful approaches that are not KL-based.

  14. Recovery of small bioparticles by interfacial partitioning.

    PubMed

    Jauregi, P; Hoeben, M A; van der Lans, R G J M; Kwant, G; van der Wielen, L A M

    2002-05-20

    In this article, a qualitative study of the recovery of small bioparticles by interfacial partitioning in liquid-liquid biphasic systems is presented. A range of crystallised biomolecules with varying polarities have been chosen such as glycine, phenylglycine and ampicillin. Liquid-liquid biphasic systems in a range of polarity differences were selected such as an aqueous two-phase system (ATPS), water-butanol and water-hexanol. The results indicate that interfacial partitioning of crystals occurs even when their density exceeds that of the individual liquid phases. Yet, not all crystals partition to the same extent to the interface to form a stable and thick interphase layer. This indicates some degree of selectivity. From the analysis of these results in relation to the physicochemical properties of the crystals and the liquid phases, a hypothetical mechanism for the interfacial partitioning is deduced. Overall these results support the potential of interfacial partitioning as a large scale separation technology.

  15. Fabrication of Al/Diamond Particles Functionally Graded Materials by Centrifugal Sintered-Casting Method

    NASA Astrophysics Data System (ADS)

    Watanabe, Yoshimi; Shibuya, Masafumi; Sato, Hisashi

    2013-03-01

    The continuous graded structure of functionally graded materials (FGMs) can be created under a centrifugal force. Centrifugal sintered-casting (CSC) method, proposed by the authors, is one of the fabrication methods of FGM under centrifugal force. This method is a combination of the centrifugal sintering method and centrifugal casting method. In this study, Al/diamond particle FGM was fabricated by the proposed method.

  16. Cerebral Hypoperfusion Precedes Nausea During Centrifugation

    NASA Technical Reports Server (NTRS)

    Serrador, Jorge M.; Schlegel, Todd T.; Black, F. Owen; Wood, Scott J.

    2004-01-01

    Nausea and motion sickness are important operational concerns for aviators and astronauts. Understanding underlying mechanisms associated with motion sickness may lead to new treatments. The goal of this work was to determine if cerebral blood flow changes precede the development of nausea in motion sick susceptible subjects. Cerebral flow velocity in the middle cerebral artery (transcranial Doppler), blood pressure (Finapres) and end-tidal CO2 were measured while subjects were rotated on a centrifuge (250 degrees/sec). Following 5 min of rotation, subjects were translated 0.504 m off-center, creating a +lGx centripetal acceleration in the nasal-occipital plane. Ten subjects completed the protocol without symptoms while 5 developed nausea (4 while 6ff-center and 1 while rotating on-center). Prior to nausea, subjects had significant increases in blood pressure (+13plus or minus 3 mmHg, P less than 0.05) and cerebrovascular resistance (+46 plus or minus 17%, P less than 0.05) and decreases in cerebral flow velocity both in the second (-13 plus or minus 4%) and last minute (-22 plus or minus 5%) before symptoms (P less than 0.05). In comparison, controls demonstrated no change in blood pressure or cerebrovascular resistance in the last minute of off-center rotation and only a 7 plus or minus 2% decrease in cerebral flow velocity. All subjects had significant hypocapnia (-3.8 plus or minus 0.4 mmHg, P less than 0.05), however this hypocapnia could not fully explain the cerebral hypoperfusion associated with the development of nausea. These data indicate that reductions in cerebral blood flow precede the development of nausea. Further work is necessary to determine what role cerebral hypoperfusion plays in motion sickness and whether cerebral hypoperfusion can be used to predict the development of nausea in susceptible individuals.

  17. Gas-particle partitioning of primary organic aerosol emissions: (1) Gasoline vehicle exhaust

    NASA Astrophysics Data System (ADS)

    May, Andrew A.; Presto, Albert A.; Hennigan, Christopher J.; Nguyen, Ngoc T.; Gordon, Timothy D.; Robinson, Allen L.

    2013-10-01

    The gas-particle partitioning of the primary organic aerosol (POA) emissions from fifty-one light-duty gasoline vehicles (model years 1987-2012) was investigated at the California Air Resources Board Haagen-Smit Laboratory. Each vehicle was operated over the cold-start unified cycle on a chassis dynamometer and its emissions were sampled using a constant volume sampler. Four independent yet complementary approaches were used to investigate POA gas-particle partitioning: sampling artifact correction of quartz filter data, dilution from the constant volume sampler into a portable environmental chamber, heating in a thermodenuder, and thermal desorption/gas chromatography/mass spectrometry analysis of quartz filter samples. This combination of techniques allowed gas-particle partitioning measurements to be made across a wide range of atmospherically relevant conditions - temperatures of 25-100 °C and organic aerosol concentrations of <1-600 μg m-3. The gas-particle partitioning of the POA emissions varied continuously over this entire range of conditions and essentially none of the POA should be considered non-volatile. Furthermore, for most vehicles, the low levels of dilution used in the constant volume sampler created particle mass concentrations that were greater than a factor of 10 or higher than typical ambient levels. This resulted in large and systematic partitioning biases in the POA emission factors compared to more dilute atmospheric conditions, as the POA emission rates may be over-estimated by nearly a factor of four due to gas-particle partitioning at higher particle mass concentrations. A volatility distribution was derived to quantitatively describe the measured gas-particle partitioning data using absorptive partitioning theory. Although the POA emission factors varied by more than two orders of magnitude across the test fleet, the vehicle-to-vehicle differences in gas-particle partitioning were modest. Therefore, a single volatility distribution

  18. Study of Ether-, Alcohol-, or Cyano-Functionalized Ionic Liquids Using Inverse Gas Chromatography

    SciTech Connect

    Revelli, Anne-Laure; Mutelet, Fabrice; Jaubert, Jean-Noel; Garcia-Martinez, Marina; Sprunger, Laura; Acree, William; Baker, Gary A

    2010-01-01

    Activity coefficients of 52 organic compounds in four ionic liquids (ILs), 1,3-dimethoxyimidazolium bis((trifluoromethyl)sulfonyl)imide, 1-(methylethylether)-3-methylimidazolium bis((trifluoromethyl)sulfonyl) imide, 1-ethanol-3-methylimidazolium bis((trifluoromethyl)-sulfonyl)imide, and 1-(3-cyanopropyl)-3- methylimidazolium dicyanamide, were measured using inverse gas chromatography from (312 to 353) K. The retention data were also converted in gas-to-IL partition coefficients and water-to-IL partition coefficients using the corresponding gas-to-water partition coefficients. Both sets of partition coefficients were analyzed using the modified Abraham solvation parameter model. The derived equations correlated the experimental gas-to-IL and water-to-IL partition coefficient data to within (0.09 and 0.14) log units, respectively.

  19. Basic Principles of Chromatography

    NASA Astrophysics Data System (ADS)

    Ismail, Baraem; Nielsen, S. Suzanne

    Chromatography has a great impact on all areas of analysis and, therefore, on the progress of science in general. Chromatography differs from other methods of separation in that a wide variety of materials, equipment, and techniques can be used. [Readers are referred to references (1-19) for general and specific information on chromatography.]. This chapter will focus on the principles of chromatography, mainly liquid chromatography (LC). Detailed principles and applications of gas chromatography (GC) will be discussed in Chap. 29. In view of its widespread use and applications, high-performance liquid chromatography (HPLC) will be discussed in a separate chapter (Chap. 28). The general principles of extraction are first described as a basis for understanding chromatography.

  20. Determination of sulfonamides in swine muscle after salting-out assisted liquid extraction with acetonitrile coupled with back-extraction by a water/acetonitrile/dichloromethane ternary component system prior to high-performance liquid chromatography.

    PubMed

    Tsai, Wen-Hsien; Huang, Tzou-Chi; Chen, Ho-Hsien; Wu, Yuh-Wern; Huang, Joh-Jong; Chuang, Hung-Yi

    2010-01-15

    A salting-out assisted liquid extraction coupled with back-extraction by a water/acetonitrile/dichloromethane ternary component system combined with high-performance liquid chromatography with diode-array detection (HPLC-DAD) was developed for the extraction and determination of sulfonamides in solid tissue samples. After the homogenization of the swine muscle with acetonitrile and salt-promoted partitioning, an aliquot of 1 mL of the acetonitrile extract containing a small amount of dichloromethane (250-400 microL) was alkalinized with diethylamine. The clear organic extract obtained by centrifugation was used as a donor phase and then a small amount of water (40-55 microL) could be used as an acceptor phase to back-extract the analytes in the water/acetonitrile/dichloromethane ternary component system. In the back-extraction procedure, after mixing and centrifuging, the sedimented phase would be water and could be withdrawn easily into a microsyringe and directly injected into the HPLC system. Under the optimal conditions, recoveries were determined for swine muscle fortified at 10 ng/g and quantification was achieved by matrix-matched calibration. The calibration curves of five sulfonamides showed linearity with the coefficient of estimation above 0.998. Relative recoveries for the analytes were all from 96.5 to 109.2% with relative standard deviation of 2.7-4.0%. Preconcentration factors ranged from 16.8 to 30.6 for 1 mL of the acetonitrile extract. Limits of detection ranged from 0.2 to 1.0 ng/g.

  1. Chromatography: concepts and contrasts

    SciTech Connect

    Miller, J.M.

    1988-01-01

    As the author states in the Preface, this text attempts to provide a unified approach to chromatography (hence the title) by way of contrasting similarities and differences between gas chromatography (GC), column liquid chromatography (LC), and thin-layer chromatography (TLC). This book is also said to be pitched at an elementary level, suitable for most newcomers to the field (e.g., advanced undergraduates and beginning graduate students in the academic world, as well as bench-level chemists in industry).

  2. Partitioned Bayesian analyses, partition choice, and the phylogenetic relationships of scincid lizards.

    PubMed

    Brandley, Matthew C; Schmitz, Andreas; Reeder, Tod W

    2005-06-01

    Partitioned Bayesian analyses of approximately 2.2 kb of nucleotide sequence data (mtDNA) were used to elucidate phylogenetic relationships among 30 scincid lizard genera. Few partitioned Bayesian analyses exist in the literature, resulting in a lack of methods to determine the appropriate number of and identity of partitions. Thus, a criterion, based on the Bayes factor, for selecting among competing partitioning strategies is proposed and tested. Improvements in both mean -lnL and estimated posterior probabilities were observed when specific models and parameter estimates were assumed for partitions of the total data set. This result is expected given that the 95% credible intervals of model parameter estimates for numerous partitions do not overlap and it reveals that different data partitions may evolve quite differently. We further demonstrate that how one partitions the data (by gene, codon position, etc.) is shown to be a greater concern than simply the overall number of partitions. Using the criterion of the 2 ln Bayes factor > 10, the phylogenetic analysis employing the largest number of partitions was decisively better than all other strategies. Strategies that partitioned the ND1 gene by codon position performed better than other partition strategies, regardless of the overall number of partitions. Scincidae, Acontinae, Lygosominae, east Asian and North American "Eumeces" + Neoseps; North African Eumeces, Scincus, and Scincopus, and a large group primarily from sub-Saharan Africa, Madagascar, and neighboring islands are monophyletic. Feylinia, a limbless group of previously uncertain relationships, is nested within a "scincine" clade from sub-Saharan Africa. We reject the hypothesis that the nearly limbless dibamids are derived from within the Scincidae, but cannot reject the hypothesis that they represent the sister taxon to skinks. Amphiglossus, Chalcides, the acontines Acontias and Typhlosaurus, and Scincinae are paraphyletic. The globally widespread

  3. REE Partitioning in Lunar Minerals

    NASA Technical Reports Server (NTRS)

    Rapp, J. F.; Lapen, T. J.; Draper, D. S.

    2015-01-01

    Rare earth elements (REE) are an extremely useful tool in modeling lunar magmatic processes. Here we present the first experimentally derived plagioclase/melt partition coefficients in lunar compositions covering the entire suite of REE. Positive europium anomalies are ubiquitous in the plagioclase-rich rocks of the lunar highlands, and complementary negative Eu anomalies are found in most lunar basalts. These features are taken as evidence of a large-scale differentiation event, with crystallization of a global-scale lunar magma ocean (LMO) resulting in a plagioclase flotation crust and a mafic lunar interior from which mare basalts were subsequently derived. However, the extent of the Eu anomaly in lunar rocks is variable. Fagan and Neal [1] reported highly anorthitic plagioclase grains in lunar impact melt rock 60635,19 that displayed negative Eu anomalies as well as the more usual positive anomalies. Indeed some grains in the sample are reported to display both positive and negative anomalies. Judging from cathodoluminescence images, these anomalies do not appear to be associated with crystal overgrowths or zones.

  4. Spectral partitioning in diffraction tomography

    SciTech Connect

    Lehman, S K; Chambers, D H; Candy, J V

    1999-06-14

    The scattering mechanism of diffraction tomography is described by the integral form of the Helmholtz equation. The goal of diffraction tomography is to invert this equation in order to reconstruct the object function from the measured scattered fields. During the forward propagation process, the spatial spectrum of the object under investigation is ''smeared,'' by a convolution in the spectral domain, across the propagating and evanescent regions of the received field. Hence, care must be taken in performing the reconstruction, as the object's spectral information has been moved into regions where it may be considered to be noise rather than useful information. This will reduce the quality and resolution of the reconstruction. We show haw the object's spectrum can be partitioned into resolvable and non-resolvable parts based upon the cutoff between the propagating and evanescent fields. Operating under the Born approximation, we develop a beam-forming on transmit approach to direct the energy into either the propagating or evanescent parts of the spectrum. In this manner, we may individually interrogate the propagating and evanescent regions of the object spectrum.

  5. Partitioning of regular computation on multiprocessor systems

    NASA Technical Reports Server (NTRS)

    Lee, Fung Fung

    1988-01-01

    Problem partitioning of regular computation over two dimensional meshes on multiprocessor systems is examined. The regular computation model considered involves repetitive evaluation of values at each mesh point with local communication. The computational workload and the communication pattern are the same at each mesh point. The regular computation model arises in numerical solutions of partial differential equations and simulations of cellular automata. Given a communication pattern, a systematic way to generate a family of partitions is presented. The influence of various partitioning schemes on performance is compared on the basis of computation to communication ratio.

  6. Partitioning of regular computation on multiprocessor systems

    NASA Technical Reports Server (NTRS)

    Lee, Fung F.

    1990-01-01

    Problem partitioning of regular computation over two dimensional meshes on multiprocessor systems is examined. The regular computation model considered involves repetitive evaluation of values at each mesh point with local communication. The computational workload and the communication pattern are the same at each mesh point. The regular computation model arises in numerical solutions of partial differential equations and simulations of cellular automata. Given a communication pattern, a systematic way to generate a family of partitions is presented. The influence of various partitioning schemes on performance is compared on the basis of computation to communication ratio.

  7. Partitioning of regular computation on multiprocessor systems

    SciTech Connect

    Lee, F. . Computer Systems Lab.)

    1990-07-01

    Problem partitioning of regular computation over two-dimensional meshes on multiprocessor systems is examined. The regular computation model considered involves repetitive evaluation of values at each mesh point with local communication. The computational workload and the communication pattern are the same at each mesh point. The regular computation model arises in numerical solutions of partial differential equations and simulations of cellular automata. Given a communication pattern, a systematic way to generate a family of partitions is presented. The influence of various partitioning schemes on performance is compared on the basis of computation to communication ratio.

  8. [The analytical setting of rotary speed of centrifuge rotor and centrifugation time in chemical, biochemical and microbiological practice].

    PubMed

    Zolotarev, K V

    2012-08-01

    The researchers happen to face with suspensions in their chemical, biochemical and microbiological practice. The suspensions are the disperse systems with solid dispersed phase and liquid dispersion medium and with dispersed phase particle size > 100 nm (10-7 m). Quite often the necessity occurs to separate solid particles from liquid. To use for this purpose the precipitation in gravitation field can make the process to progress too long. In this respect an effective mode is the precipitation in the field of centrifugal forces--the centrifugation. The rotary speed of centrifuge rotor and centrifugation time can be set analytically using regularities of general dynamics and hydrodynamics. To this effect, should be written and transformed the equation of First and Second Newton Laws for suspension particle being in the field of centrifugal forces and forces of resistance of liquid and vessel wall. The force of liquid resistance depends on particle motion condition in liquid. To determine the regimen the Archimedes and Reynolds numerical dimensionless criteria are to be applied. The article demonstrates the results of these transformations as analytical inverse ratio dependence of centrifugation time from rotary speed. The calculation of series of "rate-time" data permits to choose the optimal data pair on the assumption of centrifuge capacity and practical reasonability. The results of calculations are validated by actual experimental data hence the physical mathematical apparatus can be considered as effective one. The setting progress depends both from parameter (Reynolds criterion) and data series calculation. So, the most convenient way to apply this operation is the programming approach. The article proposes to use the program Microsoft Excel and VBA programming language for this purpose. The possibility to download the file from Internet to use it for fast solution is proposed.

  9. A fuzzy controlled three-phase centrifuge for waste separation

    SciTech Connect

    Parkinson, W.J.; Smith, R.E.; Miller, N.

    1998-02-01

    The three-phase centrifuge technology discussed in this paper was developed by Neal Miller, president of Centech, Inc. The three-phase centrifuge is an excellent device for cleaning up oil field and refinery wastes which are typically composed of hydrocarbons, water, and solids. The technology is unique. It turns the waste into salable oil, reusable water, and landfill-able solids. No secondary waste is produced. The problem is that only the inventor can set up and run the equipment well enough to provide an optimal cleanup. Demand for this device has far exceeded a one man operation. There is now a need for several centrifuges to be operated at different locations at the same time. This has produced a demand for an intelligent control system, one that could replace a highly skilled operator, or at least supplement the skills of a less experienced operator. The control problem is ideally suited to fuzzy logic, since the centrifuge is a highly complicated machine operated entirely by the skill and experience of the operator. A fuzzy control system was designed for and used with the centrifuge.

  10. Exosome enrichment of human serum using multiple cycles of centrifugation.

    PubMed

    Kim, Jeongkwon; Tan, Zhijing; Lubman, David M

    2015-09-01

    In this work, we compared the use of repeated cycles of centrifugation at conventional speeds for enrichment of exosomes from human serum compared to the use of ultracentrifugation (UC). After removal of cells and cell debris, a speed of 110 000 × g or 40 000 × g was used for the UC or centrifugation enrichment process, respectively. The enriched exosomes were analyzed using the bicinchoninic acid assay, 1D gel separation, transmission electron microscopy, Western blotting, and high-resolution LC-MS/MS analysis. It was found that a five-cycle repetition of UC or centrifugation is necessary for successful removal of nonexosomal proteins in the enrichment of exosomes from human serum. More significantly, 5× centrifugation enrichment was found to provide similar or better performance than 5× UC enrichment in terms of enriched exosome protein amount, Western blot band intensity for detection of CD-63, and numbers of identified exosome-related proteins and cluster of differentiation (CD) proteins. A total of 478 proteins were identified in the LC-MS/MS analyses of exosome proteins obtained from 5× UCs and 5× centrifugations including many important CD membrane proteins. The presence of previously reported exosome-related proteins including key exosome protein markers demonstrates the utility of this method for analysis of proteins in human serum.

  11. Development of a Feeder for Uninterrupted Centrifugation Studies

    NASA Technical Reports Server (NTRS)

    Mulenburg, Gerald M.; Vasques, Marilyn F.; Gundo, Daniel P.; Griffith, Jon B.; Wade, Charles E. (Technical Monitor)

    1994-01-01

    A specialized paste diet feeder was developed in support of a hypergravity (2G) centrifuge study. The centrifuge study was to be compared to a previously flown Russian Cosmos spaceflight so experimental parameters of the 14 day spaceflight had to be duplicated. In order to duplicate at hyper G an experiment that took place in weightlessness, all other conditions must be as identical as possible. Stopping the centrifuge to provide maintenance for the animals causes unacceptable changes in experimental research results. Thus the experimental protocol required the delivery of a designated amount of paste diet at regular intervals for a two week period without stopping the centrifuge. A centrifuge and a stationary control cage, each containing 10 laboratory rats, were fitted with feeders that were calibrated to provide 140 plus or minus 2g of paste diet every 6 hours. This paper describes development of the feeder design and results of its operation over the two week experiment. The design philosophy and details of the feeder system are provided with recommendations for future such devices.

  12. Centrifuges and Their Application for Biological Experiments in Space

    NASA Astrophysics Data System (ADS)

    Brinckmann, Enno

    2012-12-01

    The need for an in-orbit 1×g control originated from the fact that Space radiation or other environmental factors of Space flight could not be excluded as cause for the effects on biological systems that were mainly interpreted as effects of the weightlessness environment. Indeed, in many experiments the 1×g reference centrifuge on board revealed the same data as the 1×g controls on ground, proving the lack of gravity was causing the results. In other cases, the reference centrifuge data were intermediate or clearly different to the ground data which was either due to interrupted 1×g conditions on board or to other, sometimes not well understood factors. This triggered also the development of sophisticated hardware allowing the start, i.e. the transition from 1×g to 0×g, or the termination of the experiment without stopping the centrifuge. Recently developed facilities provide also a complete life support system on the centrifuge rotor. Besides the in-flight 1×g control, acceleration experiments required a centrifuge for determination of threshold values in orbit.

  13. Centrifugation Effects on Estrous Cycling, Mating Success and Pregnancy Outcome in Rats

    NASA Technical Reports Server (NTRS)

    Ronca, April E.; Rushing, Linda S.; Tou, Janet; Wade, Charles E.; Baer, Lisa A.

    2005-01-01

    We analyzed the effects of 2-g centrifugation on estrous cycling, mating success and pregnancy outcome in rats. Sexually mature female and male rats were assigned to either 2-g centrifuge or non-centrifuge conditions, and to non-breeding or breeding conditions. In non-breeding females, estrous cycles were analyzed by examining vaginal cytology before and for 35 days during centrifugation. Breeding females were time-mated following 7 days of adaptation to centrifugation. Following adaptation to centrifugation, estrous cycle duration over a five-cycle period was similar in centrifuged and non-centrifuged females. Identical numbers of centrifuged and non-centrifuged females conceived, however centrifuged females took four-times longer than controls to achieve conception. Births occurred at the normal gestational length. Pup birth weight and postnatal survival were p<0.05 reduced in centrifuged as compared to non-centrifuged groups. In conclusion, 2-g centrifugation had no effect on estrous cycle length or the probably of becoming pregnant but delayed conception and diminished pregnancy outcome.

  14. Centrifugation effects on estrous cycle, mating success and pregnancy outcome in rats

    NASA Astrophysics Data System (ADS)

    Ronca, April E.; Rushing, Linda; Tou, Janet; Wade, Charles E.; Baer, Lisa A.

    2005-08-01

    We analyzed the effects of 2-g centrifugation on estrous cycling, mating success and pregnancy outcome in rats. Sexually mature female and male rats were assigned to either 2-g centrifuge or non-centrifuge conditions, and to non-breeding or breeding conditions. In non-breeding females, estrous cycles were analyzed by examining vaginal cytology before and for 35 days during centrifugation. Breeding females were time-mated following 7 days of adaptation to centrifugation. Following adaptation to centrifugation, estrous cycle duration over a five-cycle period was similar in centrifuged and non-centrifuged females. Identical numbers of centrifuged and non-centrifuged females conceived, however centrifuged females took four-times longer than controls to achieve conception. Births occurred at the normal gestational length. Pup birth weight and postnatal survival were p<0.05 reduced in centrifuged as compared to non-centrifuged groups. In conclusion, 2-g centrifugation had no effect on estrus cycle length or the probably of becoming pregnant but delayed conception and diminished pregnancy outcome.

  15. Centrifuge Techniques and Apparatus for Transport Experiments in Porous Media

    SciTech Connect

    Earl D. Mattson; Carl D. Paler; Robert W. Smith; Markus Flury

    2010-06-01

    This paper describes experimental approaches and apparatus that we have developed to study solute and colloid transport in porous media using Idaho National Laboratory's 2-m radius centrifuge. The ex-perimental techniques include water flux scaling with applied acceleration at the top of the column and sub-atmospheric pressure control at the column base, automation of data collection, and remote experimental con-trol over the internet. These apparatus include a constant displacement piston pump, a custom designed liquid fraction collector based on switching valve technology, and modified moisture monitoring equipment. Suc-cessful development of these experimental techniques and equipment is illustrated through application to transport of a conservative tracer through unsaturated sand column, with centrifugal acceleration up to 40 gs. Development of such experimental equipment that can withstand high accelerations enhances the centrifuge technique to conduct highly controlled unsaturated solute/colloid transport experiments and allows in-flight liquid sample collection of the effluent.

  16. Oscillatory Counter-Centrifugation: Effects of History and Lift Forces

    NASA Astrophysics Data System (ADS)

    Nadim, Ali

    2014-11-01

    This work is co-authored with my doctoral student Shujing Xu and is dedicated to the memory of my doctoral advisor Howard Brenner who enjoyed thought experiments related to rotating systems. Oscillatory Counter-Centrifugation refers to our theoretical discovery that within a liquid-filled container that rotates in an oscillatory manner about a fixed axis as a rigid body, a suspended particle can be made to migrate on average in the direction opposite to that of ordinary centrifugation. That is, a heavy (or light) particle can move toward (or away from) the rotation axis, when the frequency of oscillations is high enough. In this work we analyze the effects of the Basset history force and the Saffman lift force on particle trajectories and find that the counter-centrifugation phenomenon persists even when these forces are active.

  17. Space Station Centrifuge: A Requirement for Life Science Research

    NASA Technical Reports Server (NTRS)

    Smith, Arthur H.; Fuller, Charles A.; Johnson, Catherine C.; Winget, Charles M.

    1992-01-01

    A centrifuge with the largest diameter that can be accommodated on Space Station Freedom is required to conduct life science research in the microgravity environment of space. (This was one of the findings of a group of life scientists convened at the University of California, Davis, by Ames Research Center.) The centrifuge will be used as a research tool to understand how gravity affects biological processes; to provide an on-orbit one-g control; and to assess the efficacy of using artificial gravity to counteract the deleterious biological effect of space flight. The rationale for the recommendation and examples of using ground-based centrifugation for animal and plant acceleration studies are presented. Included are four appendixes and an extensive bibliography of hypergravity studies.

  18. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, R.F.

    1994-02-15

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation. 4 figures.

  19. Operation effectiveness of wells by enhancing the electric- centrifugal pump

    NASA Astrophysics Data System (ADS)

    Zyatikov, P. N.; Kozyrev, I. N.; Deeva, V. S.

    2016-09-01

    We present the method to improve the operation effectiveness of wells by enhancing the electric-centrifugal pump. Some of the best ways to extend the electric-centrifugal pumps operating lifetime is using today's techniques as well as additional protective equipment as a part of the electric-centrifugal pump. In paper it is shown that high corrosiveness of formation fluid (a multi-component medium composed of oil, produced water, free and dissolved gases) is a major cause of failures of downhole equipment. Coil tubing is the most efficient technology to deal with this problem. The experience of coil tubing operations has proved that high-quality bottom hole cleaning saving the cost of operation due to a decreased failure rate of pumps associated with ejection of mechanical impurity.

  20. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, Richard F.

    1994-01-01

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation.

  1. Design Optimization of a Centrifugal Fan with Splitter Blades

    NASA Astrophysics Data System (ADS)

    Heo, Man-Woong; Kim, Jin-Hyuk; Kim, Kwang-Yong

    2015-05-01

    Multi-objective optimization of a centrifugal fan with additionally installed splitter blades was performed to simultaneously maximize the efficiency and pressure rise using three-dimensional Reynolds-averaged Navier-Stokes equations and hybrid multi-objective evolutionary algorithm. Two design variables defining the location of splitter, and the height ratio between inlet and outlet of impeller were selected for the optimization. In addition, the aerodynamic characteristics of the centrifugal fan were investigated with the variation of design variables in the design space. Latin hypercube sampling was used to select the training points, and response surface approximation models were constructed as surrogate models of the objective functions. With the optimization, both the efficiency and pressure rise of the centrifugal fan with splitter blades were improved considerably compared to the reference model.

  2. Solvent-free cleaning using a centrifugal cryogenic pellet accelerator

    SciTech Connect

    Haines, J.R.; Fisher, P.W.; Foster, C.A.

    1995-06-01

    An advanced centrifuge that accelerates frozen CO{sub 2} pellets to high speeds for surface cleaning and paint removal is being developed at the Oak Ridge National Laboratory. The centrifuge-based accelerator was designed, fabricated, and tested under a program sponsored by the Warner Robins Air Logistics Center, Robins Air Force Base, Georgia. In comparison to the more conventional compressed air ``sandblast`` pellet accelerators, the centrifugal accelerator system can achieve higher pellet speeds, has precise speed control, and is more than ten times as energy efficient. Furthermore, the use of frozen CO{sub 2} pellets instead of conventional metal, plastic, sand, or other abrasive materials that remain solid at room temperature, minimizes the waste stream. This apparatus has been used to demonstrate cleaning of various surfaces, including removal of paint, oxide coatings, metal coatings, organic coatings, and oil and grease coatings from a variety of surfaces. The design and operation of the apparatus is discussed.

  3. Passively Shunted Piezoelectric Damping of Centrifugally-Loaded Plates

    NASA Technical Reports Server (NTRS)

    Duffy, Kirsten P.; Provenza, Andrew J.; Trudell, Jeffrey J.; Min, James B.

    2009-01-01

    Researchers at NASA Glenn Research Center have been investigating shunted piezoelectric circuits as potential damping treatments for turbomachinery rotor blades. This effort seeks to determine the effects of centrifugal loading on passively-shunted piezoelectric - damped plates. Passive shunt circuit parameters are optimized for the plate's third bending mode. Tests are performed both non-spinning and in the Dynamic Spin Facility to verify the analysis, and to determine the effectiveness of the damping under centrifugal loading. Results show that a resistive shunt circuit will reduce resonant vibration for this configuration. However, a tuned shunt circuit will be required to achieve the desired damping level. The analysis and testing address several issues with passive shunt circuit implementation in a rotating system, including piezoelectric material integrity under centrifugal loading, shunt circuit implementation, and tip mode damping.

  4. Hydraulic and Clean-in-Place Evaluations for a 12.5-cm Annular Centrifugal Contactor at INL

    SciTech Connect

    Troy G. Garn; David H. Meikrantz; Nick R. Mann; Jack D. Law; Terry A. Todd

    2008-09-01

    Hydraulic and Clean-in-Place Evaluations for a 12.5 cm Annular Centrifugal Contactor at the INL Troy G. Garn, Dave H. Meikrantz, Nick R. Mann, Jack D. Law, Terry A. Todd Idaho National Laboratory Commercially available, Annular Centrifugal Contactors (ACC) are currently being evaluated for processing dissolved nuclear fuel solutions to selectively partition integrated elements using solvent extraction technologies. These evaluations include hydraulic and clean-in-place (CIP) testing of a commercially available 12.5 cm unit. Data from these evaluations is used to support design of future nuclear fuel reprocessing facilities. Hydraulic testing provides contactor throughput performance data on two-phase systems for a wide range of operating conditions. Hydraulic testing results on a simple two-phase oil and water system followed by a 30 % Tributyl phosphate in N-dodecane / nitric acid pair are reported. Maximum total throughputs for this size contactor ranged from 20 to 32 liters per minute without significant other phase carryover. A relatively new contactor design enhancement providing Clean-in-Place capability for ACCs was also investigated. Spray nozzles installed into the central rotor shaft allow the rotor internals to be cleaned, offline. Testing of the solids capture of a diatomaceous earth/water slurry feed followed by CIP testing was performed. Solids capture efficiencies of >95% were observed for all tests and short cold water cleaning pulses proved successful at removing solids from the rotor.

  5. Merging Groups to Maximize Object Partition Comparison.

    ERIC Educational Resources Information Center

    Klastorin, T. D.

    1980-01-01

    The problem of objectively comparing two independently determined partitions of N objects or variables is discussed. A similarity measure based on the simple matching coefficient is defined and related to previously suggested measures. (Author/JKS)

  6. Cell Partition in Two Polymer Aqueous Phases

    NASA Technical Reports Server (NTRS)

    Harris, J. M.

    1985-01-01

    Partition of biological cells in two phase aqueous polymer systems is recognized as a powerful separation technique which is limited by gravity. The synthesis of new, selective polymer ligand conjugates to be used in affinity partition separations is of interest. The two most commonly used polymers in two phase partitioning are dextran and polyethylene glycol. A thorough review of the chemistry of these polymers was begun, particularly in the area of protein attachment. Preliminary studies indicate the importance in affinity partitioning of minimizing gravity induced randomizing forces in the phase separation process. The PEG-protein conjugates that were prepared appear to be ideally suited for achieving high quality purifications in a microgravity environment. An interesting spin-off of this synthetic work was the observation of catalytic activity for certain of our polymer derivatives.

  7. Synthesis on evaporation partitioning using stable isotopes

    NASA Astrophysics Data System (ADS)

    Coenders-Gerrits, Miriam; Bogaard, Thom; Wenninger, Jochen; Jonson Sutanto, Samuel

    2015-04-01

    Partitioning of evaporation into productive (transpiration) and non-productive evaporation (interception, soil evaporation) is of highest importance for water management practices, irrigation scheme design, and climate modeling. Despite this urge, the magnitude of the ratio of transpiration over total evaporation is still under debate and poorly understood due to measuring difficulties. However, with the current development in isotope measuring devices, new opportunities arise to untangle the partitioning of evaporation. In this paper we synthesize the opportunities and limitations using stable water isotopes in evaporation partitioning. We will analyze a set of field as well as laboratory studies to demonstrate the different evaporation components for various climate and vegetation conditions using stable isotopes 18O/16O and 2H/1H. Experimental data on evaporation partitioning of crops, grass, shrubs and trees are presented and we will discuss the specific experimental set-ups and data collection methods. The paper will be a synthesis of these studies.

  8. Reducing variance in batch partitioning measurements

    SciTech Connect

    Mariner, Paul E.

    2010-08-11

    The partitioning experiment is commonly performed with little or no attention to reducing measurement variance. Batch test procedures such as those used to measure K{sub d} values (e.g., ASTM D 4646 and EPA402 -R-99-004A) do not explain how to evaluate measurement uncertainty nor how to minimize measurement variance. In fact, ASTM D 4646 prescribes a sorbent:water ratio that prevents variance minimization. Consequently, the variance of a set of partitioning measurements can be extreme and even absurd. Such data sets, which are commonplace, hamper probabilistic modeling efforts. An error-savvy design requires adjustment of the solution:sorbent ratio so that approximately half of the sorbate partitions to the sorbent. Results of Monte Carlo simulations indicate that this simple step can markedly improve the precision and statistical characterization of partitioning uncertainty.

  9. Connections between groundwater flow and transpiration partitioning

    NASA Astrophysics Data System (ADS)

    Maxwell, Reed M.; Condon, Laura E.

    2016-07-01

    Understanding freshwater fluxes at continental scales will help us better predict hydrologic response and manage our terrestrial water resources. The partitioning of evapotranspiration into bare soil evaporation and plant transpiration remains a key uncertainty in the terrestrial water balance. We used integrated hydrologic simulations that couple vegetation and land-energy processes with surface and subsurface hydrology to study transpiration partitioning at the continental scale. Both latent heat flux and partitioning are connected to water table depth, and including lateral groundwater flow in the model increases transpiration partitioning from 47 ± 13 to 62 ± 12%. This suggests that lateral groundwater flow, which is generally simplified or excluded in Earth system models, may provide a missing link for reconciling observations and global models of terrestrial water fluxes.

  10. Connections between groundwater flow and transpiration partitioning.

    PubMed

    Maxwell, Reed M; Condon, Laura E

    2016-07-22

    Understanding freshwater fluxes at continental scales will help us better predict hydrologic response and manage our terrestrial water resources. The partitioning of evapotranspiration into bare soil evaporation and plant transpiration remains a key uncertainty in the terrestrial water balance. We used integrated hydrologic simulations that couple vegetation and land-energy processes with surface and subsurface hydrology to study transpiration partitioning at the continental scale. Both latent heat flux and partitioning are connected to water table depth, and including lateral groundwater flow in the model increases transpiration partitioning from 47 ± 13 to 62 ± 12%. This suggests that lateral groundwater flow, which is generally simplified or excluded in Earth system models, may provide a missing link for reconciling observations and global models of terrestrial water fluxes.

  11. Control of centrifugal blood pump based on the motor current.

    PubMed

    Iijima, T; Inamoto, T; Nogawa, M; Takatani, S

    1997-07-01

    In this study, centrifugal pump performance was examined in a mock circulatory loop to derive an automatic pump rotational speed (rpm) control method. The pivot bearing supported sealless centrifugal pump was placed in the left ventricular apex to aorta bypass mode. The pneumatic pulsatile ventricle was used to simulate the natural ventricle. To simulate the suction effect in the ventricle, a collapsible rubber tube was placed in the inflow port of the centrifugal pump in series with the apex of the simulated ventricle. Experimentally, the centrifugal pump speed (rpm) was gradually increased to simulate the suction effect. The pump flow through the centrifugal pump measured by an electromagnetic flowmeter, the aortic pressure, and the motor current were continuously digitized at 100 Hz and stored in a personal computer. The analysis of the cross-spectral density between the pump flow and motor current waveforms revealed that 2 waveforms were highly correlated at the frequency range between 0 and 4 Hz, with the coherence and phase angles being close to 1.0 and 0 degree, respectively. The fast Fourier transform analysis of the motor current indicated that the second harmonic component of the motor current power density increased with the occurrence of the suction effect in the circuit. The ratio of the fundamental to the second harmonic component decreased less than 1.3 as the suction effect developed in the circuit. It is possible to detect and prevent the suction effect of the centrifugal blood pump in the natural ventricle through analysis of the motor current waveform.

  12. Aqueous two-phase partition applied to the isolation of plasma membranes and Golgi apparatus from cultured mammalian cells

    NASA Technical Reports Server (NTRS)

    Morre, D. M.; Morre, D. J.

    2000-01-01

    Partitioning in dextran-poly(ethylene)glycol (PEG) aqueous-aqueous phase systems represents a mature technology with many applications to separations of cells and to the preparation of membranes from mammalian cells. Most applications to membrane isolation and purification have focused on plasma membranes, plasma membrane domains and separation of right side-out and inside-out plasma membrane vesicles. The method exploits a combination of membrane properties, including charge and hydrophobicity. Purification is based upon differential distributions of the constituents in a sample between the two principal compartments of the two phases (upper and lower) and at the interface. The order of affinity of animal cell membranes for the upper phase is: endoplasmic reticulum partitioning behavior and must be precisely standardized. In some cases, it is more fortuitous to combine aqueous two-phase partition with other procedures to obtain a more highly purified preparation. A procedure is described for preparation of Golgi apparatus from transformed mammalian cells that combines aqueous two-phase partition and centrifugation. Also described is a periodic NADH oxidase, a new enzyme marker for right side-out plasma membrane vesicles not requiring detergent disruptions for measurement of activity.

  13. Colloid characterization and colloidal phase partitioning of polycyclic aromatic hydrocarbons in two creosote-contaminated aquifers in Denmark

    SciTech Connect

    Villholth, K.G.

    1999-03-01

    Colloidal matter inherent in the subsurface may provide a favorable phase for contaminant partitioning and furthermore act as agents for facilitated contaminant transport. The objectives of the present study were to determine the abundance and properties of intrinsically mobile colloids in the anoxic groundwater from two creosote-contaminated aquifers and to determine the in situ distribution of polycyclic aromatic hydrocarbons (PAHs) between the dissolved phase and two colloidal fractions. The experimental procedure comprising field sampling of bulk groundwater and a sequential laboratory fractionation scheme consisting of a centrifugation and an ultrafiltration step was designed and performed to maintain groundwater chemical and physical integrity. The colloids were identified as clay minerals, Fe-oxides, Fe-sulfides, and quartz particles containing significant amounts of organic carbon. The PAH partitioning to the coarse colloid fraction was linearly correlated with the corresponding PAH octanol-water partitioning coefficient, indicating a hydrophobic partitioning. The K{sub oc} values agreed with literature information of PAH sorption to soil organic matter.

  14. Deriving the Hirshfeld partitioning using distance metrics

    SciTech Connect

    Heidar-Zadeh, Farnaz; Ayers, Paul W.; Bultinck, Patrick

    2014-09-07

    The atoms in molecules associated with the Hirshfeld partitioning minimize the generalized Hellinger-Bhattacharya distance to the reference pro-atom densities. Moreover, the reference pro-atoms can be chosen by minimizing the distance between the pro-molecule density and the true molecular density. This provides an alternative to both the heuristic “stockholder” and the mathematical information-theoretic interpretations of the Hirshfeld partitioning. These results extend to any member of the family of f-divergences.

  15. Centrifugal inertia effects in two-phase face seal films

    NASA Technical Reports Server (NTRS)

    Basu, P.; Hughes, W. F.; Beeler, R. M.

    1987-01-01

    A simplified, semianalytical model has been developed to analyze the effect of centrifugal inertia in two-phase face seals. The model is based on the assumption of isothermal flow through the seal, but at an elevated temperature, and takes into account heat transfer and boiling. Using this model, seal performance curves are obtained with water as the working fluid. It is shown that the centrifugal inertia of the fluid reduces the load-carrying capacity dramatically at high speeds and that operational instability exists under certain conditions. While an all-liquid seal may be starved at speeds higher than a 'critical' value, leakage always occurs under boiling conditions.

  16. Apparatus and method for centrifugation and robotic manipulation of samples

    NASA Technical Reports Server (NTRS)

    Vellinger, John C. (Inventor); Ormsby, Rachel A. (Inventor); Kennedy, David J. (Inventor); Thomas, Nathan A. (Inventor); Shulthise, Leo A. (Inventor); Kurk, Michael A. (Inventor); Metz, George W. (Inventor)

    2007-01-01

    A device for centrifugation and robotic manipulation of specimen samples, including incubating eggs, and uses thereof are provided. The device may advantageously be used for the incubation of avian, reptilian or any type of vertebrate eggs. The apparatus comprises a mechanism for holding samples individually, rotating them individually, rotating them on a centrifuge collectively, injecting them individually with a fixative or other chemical reagent, and maintaining them at controlled temperature, relative humidity and atmospheric composition. The device is applicable to experiments involving entities other than eggs, such as invertebrate specimens, plants, microorganisms and molecular systems.

  17. The effect of gas fraction on centrifugal pump

    NASA Astrophysics Data System (ADS)

    Zhu, Z. T.; Wang, Y.; Zhao, L. F.; Ning, C.; Xie, S. F.; Liu, Z. C.

    2015-01-01

    In order to study the multiphase flow field in M125 centrifugal pump, three-dimensional modeling was used for internal flow through three-dimensional software Pro/E. Then based on SST turbulence model combining with Rayleigh-Plesset cavitation model, and structured grid to simulate the hydraulic characteristics of volute and impeller within different gas conditions. The velocity, pressure and gas volume fraction distributions of the interior flow field of volute and impeller were obtained and analyzed, which revealed the effect of gas fractions on the flow characteristic of the centrifugal pump.

  18. The use of centrifugation to study early Drosophila embryogenesis

    NASA Technical Reports Server (NTRS)

    Abbott, M. K.; Spooner, B. S. (Principal Investigator)

    1993-01-01

    By the end of 10th nuclear cycle, the somatic nuclei of the Drosophila embryo have migrated to the periphery of the egg. Centrifugation of embryos did not result in the displacement of these nuclei, since cytoskeletal elements anchor them to the cortex. But, mild centrifugal forces displace the centrally located, nascent yolk nuclei. If this increased sensitivity to hypergravity occurs before the beginning of nuclear differentiation during cycle 8, when the nascent yolk and somatic nuclei physically separate, then it would mark the earliest functional difference between these two lineages.

  19. 24. RW Meyer Sugar Mill: 18761889. Centrifugal inner basket, 1879. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. RW Meyer Sugar Mill: 1876-1889. Centrifugal inner basket, 1879. Manufacturer, unknown. Supplied by Honolulu Iron Works, Honolulu, Hawaii, 1879. View: After sugar was granulated and cooled it was dried and drained, completely separating the sugar crystals from the molasses, in the centrifugal. Revolving at 1200 rpm the sugar charge was forced outward with the molasses flying through the holes in the brass lining. Dried sugar was left behind in the inner basket and was dug out by hand. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI

  20. Multiplexed single-molecule force spectroscopy using a centrifuge

    PubMed Central

    Yang, Darren; Ward, Andrew; Halvorsen, Ken; Wong, Wesley P.

    2016-01-01

    We present a miniature centrifuge force microscope (CFM) that repurposes a benchtop centrifuge for high-throughput single-molecule experiments with high-resolution particle tracking, a large force range, temperature control and simple push-button operation. Incorporating DNA nanoswitches to enable repeated interrogation by force of single molecular pairs, we demonstrate increased throughput, reliability and the ability to characterize population heterogeneity. We perform spatiotemporally multiplexed experiments to collect 1,863 bond rupture statistics from 538 traceable molecular pairs in a single experiment, and show that 2 populations of DNA zippers can be distinguished using per-molecule statistics to reduce noise. PMID:26984516

  1. On the characteristics of centrifugal-reciprocating machines. [cryogenic coolers

    NASA Technical Reports Server (NTRS)

    Higa, W. H.

    1980-01-01

    A method of compressing helium gas for cryogenic coolers is presented which uses centrifugal force to reduce the forces on the connecting rod and crankshaft in the usual reciprocating compressor. This is achieved by rotating the piston-cylinder assembly at a speed sufficient for the centrifugal force on the piston to overcome the compressional force due to the working fluid. The rotating assembly is dynamically braked in order to recharge the working space with fluid. The intake stroke consists of decelerating the rotating piston-cylinder assembly and the exhaust stroke consists of accelerating the assembly.

  2. Secondary Containment Design for a High Speed Centrifuge

    SciTech Connect

    Snyder, K.W.

    1999-03-01

    Secondary containment for high speed rotating machinery, such as a centrifuge, is extremely important for operating personnel safety. Containment techniques can be very costly, ungainly and time consuming to construct. A novel containment concept is introduced which is fabricated out of modular sections of polycarbonate glazed into a Unistrut metal frame. A containment study for a high speed centrifuge is performed which includes the development of parameters for secondary containment design. The Unistrut/polycarbonate shield framing concept is presented including design details and proof testing procedures. The economical fabrication and modularity of the design indicates a usefulness for this shielding system in a wide variety of containment scenarios.

  3. Structural evolution of fold-thrust structures in analog models deformed in a large geotechnical centrifuge

    NASA Astrophysics Data System (ADS)

    Noble, Todd E.; Dixon, John M.

    2011-02-01

    We investigate the structural evolution of fault-propagation folds and fold-thrust systems with scaled analog modeling carried out using the 5.5 m radius geotechnical centrifuge at C-CORE, St. John's NL. The experiments presented here are the first of their kind, scaled ten times larger than predecessors and deformed using a custom rig with load monitoring and displacement control. Plane-layered models approximately 1 m long and representing 50 km sections are shortened horizontally under an enhanced gravity field of 160 g. The large model scale allows for a proportionally large number of bedding laminations that act as strain markers. This allows detailed analysis of strain partitioning and interplay, both at the scale of a fold-thrust system and the individual fold-thrust structure. Layer-parallel shortening ("LPS") and rotation of fault-bounded blocks are revealed by mapping contraction fault populations and bedding-contraction fault intersection angles. Low-angle contraction faulting and LPS are found to be dominant at early stages of development and rotation of fault-bounded blocks occurs during progressive folding of the hanging-wall panel during fault-propagation folding. Displacement-distance data obtained from major thrusts in the model show relative stretch values, and consequently fault slip/propagation ratios, that are similar to natural structures.

  4. Experimental and Theoretical Study on Circular Disk Particles Suspended in Centrifugal and Non-Centrifugal Force Environments

    SciTech Connect

    Torii, Shuichi; Watanabe, Yoshimi; Tanaka, Satoyuki; Yano, Toshiaki; Iino, Naoko

    2008-02-15

    Theoretical and experimental studies are performed on suspension particle motion in Centrifugal and Non-Centrifugal Force Environment, i.e., in both an axially rotating drum and a stable liquid tank. The particle velocity of circular disks is measured by PTV (Particle Tracking Velocimetry) method and is predicted by BBO (Basset-Boussinesq-Ossen) equation. It is found that (1) as time progresses, one side of the disk in the axially rotating drum is attracted toward the drum wall and its velocity is affected by the rotating speed, (2) when the particle moves in the Stokes' regime, its velocity is linearly increased with the distance from the center of the drum, (3) in contrast, the autorotation of the disk occurs in the non-centrifugal force field, and (4) the corresponding drag coefficient in the low Reynolds number region is in good agreement with the theoretical value of the sphere.

  5. Certificate Revocation Using Fine Grained Certificate Space Partitioning

    NASA Astrophysics Data System (ADS)

    Goyal, Vipul

    A new certificate revocation system is presented. The basic idea is to divide the certificate space into several partitions, the number of partitions being dependent on the PKI environment. Each partition contains the status of a set of certificates. A partition may either expire or be renewed at the end of a time slot. This is done efficiently using hash chains.

  6. Tricaprylin-water partition coefficients and their temperature dependence for selected chlorobenzenes

    SciTech Connect

    Bahadur, N.P.; Shiu, W.Y.; Boocock, D.G.B.; Mackay, D.

    1999-01-01

    Measurements of partition coefficients between tricaprylin (glyceryl tri-n-octanoate) and water are reported for seven chlorobenzenes (1,2-dichlorobenzene, 1,4-dichlorobenzene, 1,3,5-trichlorobenzene, 1,2,3,4-tetrachlorobenzene, 1,2,3,5-tetrachlorobenzene, pentachlorobenzene, and hexachlorobenzene) between 5 and 45 C. The values are compared with reported data on octanol-water and triolein-water partition coefficients. The van`t Hoff plots of log K{sub OW} versus T{sup {minus}1} exhibit linearity with values of K{sub OW} increasing by 5--8% over this temperature range, and the enthalpy of phase change varies from 9.7 to 16 kJ/mol. Several reasons are suggested why tricaprylin-water partition coefficients may be preferable to octanol-water and triolein-water partition coefficients when quantifying a substance`s hydrophobicity. The mutual solubilities of tricaprylin and water are less than that of octanol and water. Tricaprylin is easier to purify than triolein and, because of its lower molecular mass, is easier to analyze by gas chromatography.

  7. The Maryland Centrifugal Experiment (MCX): Centrifugal Confinement and Velocity Shear Stabilization of Plasmas in Shaped Open Magnetic Systems

    SciTech Connect

    Hassam, Adil; Ellis, Richard F.

    2012-01-01

    The Maryland Centrifugal Experiment (MCX) Project has investigated the concepts of centrifugal plasma confinement and stabilization of instabilities by velocity shear. The basic requirement is supersonic plasma rotation about a shaped, open magnetic field. Overall, the MCX Project attained three primary goals that were set out at the start of the project. First, supersonic rotation at Mach number upto 2.5 was obtained. Second, turbulence from flute interchange modes was found considerably reduced from conventional. Third, plasma pressure was contained along the field, as evidenced by density drops of x10 from the center to the mirror throats.

  8. Effects of centrifugation stress on pituitary-gonadal function in male rats

    NASA Technical Reports Server (NTRS)

    Gray, G. D.; Smith, E. R.; Damassa, D. A.; Davidson, J. M.

    1980-01-01

    The effects of centrifugation for various lengths of time on circulating levels of luteinizing hormone (LH) and testosterone in male rats were investigated. In a chronic 52-day experiment, centrifugation at 4.1 G significantly reduced LH and testosterone levels for the entire period. Centrifugation at 2.3 G had less effect inasmuch as LH levels were not significantly decreased and testosterone levels were significantly reduced only during the first few days of centrifugation. In more acute experiments, centrifugation at 4.1 G for 4 h resulted in reduced testosterone levels, whereas centrifugation for 15 min did not significantly alter the hormone levels. These results indicate that centrifugation can decrease circulating LH and testosterone levels if the gravitational force is of sufficient magnitude and is maintained for a period of hours. Chronic centrifugation may also inhibit the acute excitatory response of LH to handling and ether stress.

  9. Geotechnical Centrifuge Experiments to Evaluate Piping in Foundation Soils

    DTIC Science & Technology

    2014-05-01

    Catalogue of scaling laws and similitude questions in geotechnical centrifuge modeling. IJPMG International Journal of Physical Modeling in...Technology. Sellmeijer, J. B., and M. A. Koenders. 1991. A mathematical model for piping. Applied Mathematical Modeling 15(11-12):646–651. van Beek, V

  10. Design of a piezoelectric shaker for centrifuge testing

    NASA Technical Reports Server (NTRS)

    Canclini, J. G.; Henderson, J. M.

    1979-01-01

    The design of a prototype piezoelectric shaker and its development to date is described. Although certain design problems remain to be solved, the piezoelectric system shows promise for adaptation to a larger payload system, such as the proposed geotechnical centrifuge at the Ames Research Center.

  11. Fluid forces on rotating centrifugal impeller with whirling motion

    NASA Technical Reports Server (NTRS)

    Shoji, H.; Ohashi, H.

    1980-01-01

    Fluid forces on a centrifugal impeller, whose rotating axis whirls with a constant speed, were calculated by using unsteady potential theory. Calculations were performed for various values of whirl speed, number of impeller blades and angle of blades. Specific examples as well as significant results are given.

  12. Quasi-steady centrifuge method for unsaturated hydraulic properties

    USGS Publications Warehouse

    Caputo, M.C.; Nimmo, J.R.

    2005-01-01

    [1] We have developed the quasi-steady centrifuge (QSC) method as a variation of the steady state centrifuge method that can be implemented simply and inexpensively with greater versatility in terms of sample size and other features. It achieves these advantages by somewhat relaxing the criterion for steadiness of flow through the sample. This compromise entails an increase in measurement uncertainty but to a degree that is tolerable in most applications. We have tested this new approach with an easily constructed apparatus to establish a quasi-steady flow of water in unsaturated porous rock samples spinning in a centrifuge, obtaining measurements of unsaturated hydraulic conductivity and water retention that agree with results of other methods. The QSC method is adaptable to essentially any centrifuge suitable for hydrogeologic applications, over a wide range of sizes and operating speeds. The simplified apparatus and greater adaptability of this method expands the potential for exploring situations that are common in nature but have been the subject of few laboratory investigations. Copyright 2005 by the American Geophysical Union.

  13. Prediction of performance of centrifugal pumps during starts under pressure

    NASA Technical Reports Server (NTRS)

    Rostafinski, W.

    1969-01-01

    Method which calculates start-up characteristics of centrifugal pumps reveals a capacity to predict pressure drop characteristics of pumps with vaned diffusers. Calculations are based on pump geometry, design-point flow, speed, and pressure rise, and the pump characteristic within range of approximately ten percent of the design-point flow.

  14. Latex micro-balloon pumping in centrifugal microfluidic platforms.

    PubMed

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Madou, Marc

    2014-03-07

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-step processes on a single microfluidic disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping mechanisms have been designed to study the pump performance at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data show that the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, a desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon.

  15. Measurements of the rotordynamic shroud forces for centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Guinzburg, A.; Brennen, C. E.; Acosta, A. J.; Caughey, T. K.

    1990-01-01

    An experiment was designed to measure the rotordynamic shroud forces on a centrifugal pump impeller. The measurements were done for various whirl/impeller speed ratios and for different flow rates. A destabilizing tangential force was measured for small positive whirl ratios and this force decreased with increasing flow rate.

  16. Pasteurization of grapefruit juice using a centrifugal ultraviolet light irradiator

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pharmaceutical industry uses UV irradiators to inactivate viruses in liquids without heat. The penetration depth of UV in some liquids, such as serum plasma, can be short. To overcome this, very thin films may be produced by centrifugal force, small diameter tubing, or other means. Many liquid f...

  17. Liquid egg white pasteurization using a centrifugal UV irradiator

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Studies are lacking on UV nonthermal pasteurization of liquid egg white (LEW). The objective of this study was to inactivate Escherichia coli using a UV irradiator that centrifugally formed a thin film of LEW on the inside of a rotating cylinder. The LEW was inoculated with E. coli K12 to approximat...

  18. DEMONSTRATION BULLETIN: THE PLASMA CENTRIFUGAL FURNACE RETECH, INC.

    EPA Science Inventory

    The plasma centrifugal furnace is a thermal technology which uses the heat generated from a plasma torch to decontaminate metal and organic contaminated waste. This is accomplished by melting metal-bearing solids and, in the process, thermally destroying organic contaminants. The...

  19. Numerical Simulation and Cold Modeling experiments on Centrifugal Casting

    NASA Astrophysics Data System (ADS)

    Keerthiprasad, Kestur Sadashivaiah; Murali, Mysore Seetharam; Mukunda, Pudukottah Gopaliengar; Majumdar, Sekhar

    2011-02-01

    In a centrifugal casting process, the fluid flow eventually determines the quality and characteristics of the final product. It is difficult to study the fluid behavior here because of the opaque nature of melt and mold. In the current investigation, numerical simulations of the flow field and visualization experiments on cold models have been carried out for a centrifugal casting system using horizontal molds and fluids of different viscosities to study the effect of different process variables on the flow pattern. The effects of the thickness of the cylindrical fluid annulus formed inside the mold and the effects of fluid viscosity, diameter, and rotational speed of the mold on the hollow fluid cylinder formation process have been investigated. The numerical simulation results are compared with corresponding data obtained from the cold modeling experiments. The influence of rotational speed in a real-life centrifugal casting system has also been studied using an aluminum-silicon alloy. Cylinders of different thicknesses are cast at different rotational speeds, and the flow patterns observed visually in the actual castings are found to be similar to those recorded in the corresponding cold modeling experiments. Reasonable agreement is observed between the results of numerical simulation and the results of cold modeling experiments with different fluids. The visualization study on the hollow cylinders produced in an actual centrifugal casting process also confirm the conclusions arrived at from the cold modeling experiments and numerical simulation in a qualitative sense.

  20. Pasteurization of Grapefruit Juice using a Centrifugal Ultraviolet Light Device

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The pharmaceutical industry uses UV devices to nonthermally inactivate viruses in liquids. To overcome the low penetration depth of UV in some liquids, such as serum plasma, thin films are formed by centrifugal force. Liquid foods also have low UV penetration depths. Studies are lacking on nontherma...

  1. Application of antioxidants and centrifugation for cryopreservation of boar spermatozoa.

    PubMed

    Zhang, Wei; Yi, Kangle; Chen, Chao; Hou, Xiaofeng; Zhou, Xu

    2012-06-01

    Although cryopreserved boar semen has been available since 1975, a major breakthrough in commercial application has not yet occurred due to the high susceptibility of boar spermatozoa to damage during cryopreservation and the complicated process required for deep freezing. In recent years, the application of antioxidants during the cryopreservation of boar semen has been the subject of considerable research aimed at improving the quality of post-thaw semen. Centrifugation is necessary before using cryopreservation protocols for freezing boar spermatozoa. Studies of the effect of different centrifugation regimens on boar sperm recovery, yield and cryosurvival have made significant contributions. Therefore this review elucidates results of recent applications of various antioxidants and centrifugation regimens used in efforts to improve cryopreservation of boar spermatozoa. This review is intended to enhance understanding of the roles of these antioxidants and centrifugation regimens with respect to mechanisms that increase resistance to cryodamage of boar spermatozoa. In addition, the discussion addresses the need for developing an objective evaluation of effectiveness and estimating the prospect of application of new techniques for the cryopreservation of boar semen and its use in artificial insemination.

  2. Ocular torsion before and after 1 hour centrifugation.

    PubMed

    Groen, E; De Graaf, B; Bles, W; Bos, J E

    1996-01-01

    To assess a possible otolith contribution to effects observed following prolonged exposure to hypergravity, we used video oculography to measure ocular torsion during static and dynamic conditions of lateral body tilt (roll) before and after 1 h of centrifugation with a Gx-load of 3 G. Static tilt (from 0 to 57 degrees to either side) showed a 10% decrease in otolith-induced ocular torsion after centrifugation. This implies a reduced gain of the otolith function. The dynamic condition consisted of sinusoidal body roll (frequency 0.25 Hz, amplitude 45 degrees) about an earth horizontal and about an earth vertical axis (respectively, "with" and "without" otolith stimulation). Before centrifugation the gain of the slow component velocity (SCV) was significantly lower "with" otolith stimulation than "without" otolith stimulation. Apparently, the contribution of the otoliths counteracts the ocular torsion response generated by the semicircular canals. Therefore, the observed increase in SCV gain in the condition "with" otolith stimulation after centrifugation, seems in correspondence with the decreased otolith gain in the static condition.

  3. Demonstration of Reduced Gas Pressure in a Centrifugal Field.

    ERIC Educational Resources Information Center

    Fischer, Fred; Wild, R. L.

    1979-01-01

    Describes a simple demonstration that shows the change in molecular density and the reduction in pressure of air in a centrifugal field. Uses two circular disks with the same radius and rotating with the same angular velocity, in loose mutual contact, around their symmetry axis. (GA)

  4. Effect of chronic centrifugation on body composition in the rat.

    NASA Technical Reports Server (NTRS)

    Pitts, G. C.; Bull, L. S.; Oyama, J.

    1972-01-01

    Two groups of adult female rats were chronically centrifuged for 60 days (2.76 G, 4.15 G, controls at 1.00 G). Live weights of centrifugal rats decreased about 20 g (6%) per Delta 1 G above control. This weight loss comprised reductions in both body fat and fat-free body weight (FFBW) as determined by body-composition studies on eight rats per group killed at the end of centrifugation. Of nine components constituting the FFBW, only skeletal muscle, liver, and heart changed significantly in weight. Chemical composition showed reductions (compared with controls) in the fat fraction of most components and increases in the water fraction of liver and gut. Identical measurements were made on the remaining eight rats per group killed 43 days after return to 1 G. Neither centrifuged group had reached the control body-weight level at this time. No statistically significant effect of previous G level was found in any of the body-composition parameters. The possible involvment of physiological regulation was considered.

  5. Chromatography resin support

    DOEpatents

    Dobos, James G.

    2002-01-01

    An apparatus and method of using an improved chromatography resin support is disclosed. The chromatography support platform is provided by a stainless steel hollow cylinder adapted for being inserted into a chromatography column. An exterior wall of the stainless steel cylinder defines a groove for carrying therein an "O"-ring. The upper surface of the stainless steel column is covered by a fine stainless steel mesh welded to the edges of the stainless steel cylinder. When placed upon a receiving ledge defined within a chromatography column, the "O"-ring provides a fluid tight seal with the inner edge wall of the chromatography cylinder. The stainless steel mesh supports the chromatography matrix and provides a back flushable support which is economical and simple to construct.

  6. Affinity partitioning of restriction endonucleases. Application to the purification of EcoR I and EcoR V.

    PubMed

    Vlatakis, G; Bouriotis, V

    1991-02-01

    Partitioning of restriction endonucleases between two liquid aqueous phases can be strongly influenced by group-specific ligands included in the two-phase system. Three restriction endonucleases, namely EcoR I, EcoR V and BamH I, were partitioned within an aqueous dextran-polyethylene glycol (PEG) system. The enzymes could be extracted into the upper PEG phase by using either triazine dyes or herring DNA as affinity ligands. The influence of the endogenous bacterial nucleic acids, concentration of polymerbound dye and concentration of sodium chloride on the system were examined. A partial purification of EcoR I (up to 52-fold) and EcoR V (up to 37-fold) was achieved using a combination of affinity partitioning and ion-exchange chromatography, providing an extremely fast and economical method for the isolation of restriction endonucleases free from contaminating nuclease activities.

  7. Return to Flying Duties Following Centrifuge or Vibration Exposures

    NASA Technical Reports Server (NTRS)

    Scheuring, Richard A.; Clarke, Jonathan; Jones, Jeffrey A.

    2009-01-01

    Introduction: In an effort to determine the human performance limits for vibration in spacecraft being developed by NASA, astronauts were evaluated during a simulated launch profile in a centrifuge/vibration environment and separate vibration-only simulation. Current USAF and Army standards for return to flight following centrifuge exposures require 12-24 hours to pass before a crewmember may return to flying duties. There are no standards on vibration exposures and return to flying duties. Based on direct observation and provocative neurological testing of the astronauts, a new standard for return to flying duties following centrifuge and/or vibration exposures was established. Methods: 13 astronaut participants were exposed to simulated launch profiles in a + 3.5 Gx bias centrifuge/vibration environment and separately on a vibration table at the NASA-Ames Research Center. Each subject had complete neurological evaluations pre- and post-exposure for the centrifuge/vibration runs with the NASA neurological function rating scale (NFRS). Subjects who participated in the vibration-only exposures had video oculography performed with provocative maneuvers in addition to the NFRS. NFRS evaluations occurred immediately following each exposure and at 1 hour post-run. Astronauts who remained symptomatic at 1 hour had repeat NFRS performed at 1 hour intervals until the crewmember was asymptomatic. Results: Astronauts in the centrifuge/vibration study averaged a 3-5 point increase in NFRS scores immediately following exposure but returned to baseline 3 hours post-run. Subjects exposed to the vibration-only simulation had a 1-3 point increase following exposure and returned to baseline within 1-2 hours. Pre- and post- vibration exposure video oculography did not reveal any persistent ocular findings with provocative testing 1 hour post-exposure. Discussion: Based on direct observations and objective measurement of neurological function in astronauts following simulated launch

  8. A Static Method as an Alternative to Gel Chromatography: An Experiment for the Undergraduate Biochemistry Laboratory

    ERIC Educational Resources Information Center

    Burum, Alex D.; Splittgerber, Allan G.

    2008-01-01

    This article describes a static method as an alternative to gel chromatography, which may be used as an undergraduate laboratory experiment. In this method, a constant mass of Sephadex gel is swollen in a series of protein solutions. UV-vis spectrophotometry is used to find a partition coefficient, KD, that indicates the fraction of the interior…

  9. Diverse Representations of Olfactory Information in Centrifugal Feedback Projections

    PubMed Central

    Osakada, Fumitaka; Tarabrina, Anna; Kizer, Erin; Callaway, Edward M.; Gage, Fred H.; Sejnowski, Terrence J.

    2016-01-01

    Although feedback or centrifugal projections from higher processing centers of the brain to peripheral regions have long been known to play essential functional roles, the anatomical organization of these connections remains largely unknown. Using a virus-based retrograde labeling strategy and 3D whole-brain reconstruction methods, we mapped the spatial organization of centrifugal projections from two olfactory cortical areas, the anterior olfactory nucleus (AON) and the piriform cortex, to the granule cell layer of the main olfactory bulb in the mouse. Both regions are major recipients of information from the bulb and are the largest sources of feedback to the bulb, collectively constituting circuits essential for olfactory coding and olfactory behavior. We found that, although ipsilateral inputs from the AON were uniformly distributed, feedback from the contralateral AON had a strong ventral bias. In addition, we observed that centrifugally projecting neurons were spatially clustered in the piriform cortex, in contrast to the distributed feedforward axonal inputs that these cells receive from the principal neurons of the bulb. Therefore, information carried from the bulb to higher processing structures by anatomically stereotypic projections is likely relayed back to the bulb by organizationally distinct feedback projections that may reflect different coding strategies and therefore different functional roles. SIGNIFICANCE STATEMENT Principles of anatomical organization, sometimes instantiated as “maps” in the mammalian brain, have provided key insights into the structure and function of circuits in sensory systems. Generally, these characterizations focus on projections from early sensory processing areas to higher processing structures despite considerable evidence that feedback or centrifugal projections often constitute major conduits of information flow. Our results identify structure in the organization of centrifugal feedback projections to the

  10. Fun with Paper Chromatography.

    ERIC Educational Resources Information Center

    Coleman, Dava; Hounshell, Paul B.

    1982-01-01

    Discusses paper chromatographic techniques and provides examples of typical classroom activities. Includes description of retardation values obtained during chromatography exercises and suggests using them for math lessons. (JN)

  11. Screening of pesticides for environmental partitioning tendency.

    PubMed

    Gramatica, Paola; Di Guardo, Antonio

    2002-06-01

    The partitioning tendency of chemicals, in this study pesticides in particular, into different environmental compartments depends mainly on the concurrent relevance of the physico-chemical properties of the chemical itself. To rank the pesticides according to their distribution tendencies in the different environmental compartments we propose a multivariate approach: the combination, by principal component analysis, of those physico-chemical properties like organic carbon partition coefficient (Koc), n-octanol/water partition coefficient (Kow), water solubility (Sw), vapour pressure and Henry's law constant (H) that are more relevant to the determination of environmental partitioning. The resultant macrovariables, the PC1 and PC2 scores here named leaching index (LIN) and volatality index (VIN), are proposed as preliminary environmental partitioning indexes in different media. These two indexes are modeled by theoretical molecular descriptors with satisfactory predictive power. Such an approach allows a rapid pre-determination and screening of the environmental distribution of pesticides starting only from the molecular structure of the pesticide, without any a priori knowledge of the physico-chemical properties.

  12. A biologically motivated partitioning of mortality.

    PubMed

    Carnes, B A; Olshansky, S J

    1997-01-01

    For over a century, actuaries and biologists working independently of each other have presented arguments for why total mortality needs to be partitioned into biologically meaningful subcomponents. These mortality partitions tended to overlook genetic diseases that are inherited because the partitions were motivated by a paradigm focused on aging. In this article, we combine and extend the concepts from these disciplines to develop a conceptual partitioning of total mortality into extrinsic and intrinsic causes of death. An extrinsic death is either caused or initiated by something that orginates outside the body of an individual, while an intrinsic death is either caused or initiated by processes that originate within the body. It is argued that extrinsic mortality has been a driving force in determining why we die when we do from intrinsic causes of death. This biologically motivated partitioning of mortality provides a useful perspective for researchers interested in comparative mortality analyses, the consequences of population aging, limits to human life expectancy, the progress made by the biomedical sciences against lethal diseases, and demographic models that predict the life expectancy of future populations.

  13. Octanol/air partitioning of polychlorinated biphenyls

    SciTech Connect

    Komp, P.; McLachlan, M.S.

    1997-12-01

    The partitioning of 16 polychlorinated biphenyls (PCBs) between air and 1-octanol was investigated using a fugacity meter. The measurements were conducted over an environmentally relevant temperature range (10--43 C). For a given congener the measured 1-octanol/air partition coefficient K{sub OA} was exponentially proportional to the reciprocal temperature. The enthalpy of phase change (octanol to air) {Delta}H{sub OA} ranged from 71 to 93 kJ/mol. Up to log K{sub OA} values of 9.37 (corresponding to 2,2{prime},3,4{prime},5{prime},6-hexachlorobiphenyl), the enthalpy of phase change was similar to the enthalpy of vaporization of the subcooled liquid PCB. For the less volatile congeners (log K{sub OA} > 9.37), the enthalpies of vaporization exceeded the enthalpies of phase change, the difference increasing with increasing log K{sub OA}. Solubilities of the PCBs in 1-octanol were calculated from the data, and the results were in excellent agreement with octanol solubilities calculated using the OCTASOL fragment method. A very good correlation between the measured octanol/air partition coefficients and values calculated from octanol/water and air/water partition coefficients was obtained. This yielded a method to estimate reliably the octanol/air partitioning of all PCB congeners.

  14. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device...

  15. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device...

  16. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device...

  17. 77 FR 65360 - Grant of Authority for Subzone Status (Centrifugal and Submersible Pumps); Auburn, NY

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-26

    ... Foreign-Trade Zones Board Grant of Authority for Subzone Status (Centrifugal and Submersible Pumps... subzone at the centrifugal and submersible pump manufacturing and warehousing facilities of Xylem Water... activity related to the manufacturing of centrifugal and submersible pumps and related controllers at...

  18. Cycle-powered short radius (1.9M) centrifuge: exercise vs. passive acceleration

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Gundo, D. P.; Watenpaugh, D. E.; Mulenburg, G. M.; Marchman, N.; Looft-Wilson, R.; Hargens, A. R.

    1996-01-01

    A human-powered short-arm centrifuge is described. This centrifuge could be used during spaceflight to provide +Gz acceleration while subjects performed exercise, thus supplying two forms of weightlessness countermeasures. Results from a study of cardiovascular responses while using the centrifuge are presented.

  19. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  20. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  1. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  2. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  3. 21 CFR 864.9275 - Blood bank centrifuge for in vitro diagnostic use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood bank centrifuge for in vitro diagnostic use... Manufacture Blood and Blood Products § 864.9275 Blood bank centrifuge for in vitro diagnostic use. (a) Identification. A blood bank centrifuge for in vitro diagnostic use is a device used only to separate blood...

  4. 40 CFR Appendix - Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Limits for Open Molding, Centrifugal Casting, and SMC Manufacturing Operations Where the Standards Are..., Table 5 Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC... casting—CR/HS 3,4 A vent system that moves heated air through the mold 27 lb/ton. 8. Centrifugal...

  5. 40 CFR Appendix - Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Limits for Open Molding, Centrifugal Casting, and SMC Manufacturing Operations Where the Standards Are..., Table 5 Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC... casting—CR/HS 3,4 A vent system that moves heated air through the mold 27 lb/ton. 8. Centrifugal...

  6. 40 CFR Appendix - Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Limits for Open Molding, Centrifugal Casting, and SMC Manufacturing Operations Where the Standards Are..., Subpt. WWWW, Table 5 Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and... casting—CR/HS 3,4 A vent system that moves heated air through the mold 27 lb/ton. 8. Centrifugal...

  7. 40 CFR Appendix - Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and SMC...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Limits for Open Molding, Centrifugal Casting, and SMC Manufacturing Operations Where the Standards Are..., Subpt. WWWW, Table 5 Alternative Organic HAP Emissions Limits for Open Molding, Centrifugal Casting, and... casting—CR/HS 3,4 A vent system that moves heated air through the mold 27 lb/ton. 8. Centrifugal...

  8. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device...

  9. 21 CFR 864.9285 - Automated cell-washing centrifuge for immuno-hematology.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell-washing centrifuge for immuno... Establishments That Manufacture Blood and Blood Products § 864.9285 Automated cell-washing centrifuge for immuno-hematology. (a) Identification. An automated cell-washing centrifuge for immuno-hematology is a device...

  10. The EPRL intertwiners and corrected partition function

    NASA Astrophysics Data System (ADS)

    Kamiński, Wojciech; Kisielowski, Marcin; Lewandowski, Jerzy

    2010-08-01

    Do the SU(2) intertwiners parametrize the space of the Engle, Pereira, Rovelli, Livine (EPRL) solutions to the simplicity constraint? What is the complete form of the partition function written in terms of this parametrization? We prove that the EPRL map is injective in the general n-valent vertex case for the Barbero-Immirzi parameter less than 1. We find, however, that the EPRL map is not isometric. In the consequence, a partition function can be defined either using the EPRL intertwiners Hilbert product or the SU(2) intertwiners Hilbert product. We use the EPRL one and derive a new, complete formula for the partition function. Next, we view it in terms of the SU(2) intertwiners. The result, however, goes beyond the SU(2) spin-foam models' framework and the original EPRL proposal.

  11. New parallel SOR method by domain partitioning

    SciTech Connect

    Xie, D.; Adams, L.

    1999-07-01

    In this paper the authors propose and analyze a new parallel SOR method, the PSOR method, formulated by using domain partitioning and interprocessor data communication techniques. They prove that the PSOR method has the same asymptotic rate of convergence as the Red/Black (R/B) SOR method for the five-point stencil on both strip and block partitions, and as the four-color (R/B/G/O) SOR method for the nine-point stencil on strip partitions. They also demonstrate the parallel performance of the PSOR method on four different MIMD multiprocessors (a KSR1, an Intel Delta, a Paragon, and an IBM SP2). Finally, they compare the parallel performance of PSOR, R/B SOR, and R/B/G/O SOR. Numerical results on the Paragon indicate that PSOR is more efficient than R/B SOR and R/B/G/O SOR in both computation and interprocessor data communication.

  12. Factorization of the bosonic partition function

    NASA Astrophysics Data System (ADS)

    Alsharafat, Ayed; Chair, Noureddine

    2017-04-01

    The factorization formula in the non-interacting quantum field theories that relates the fermionic partition function to the bosonic partition function considered recently by Chair (2013) [3] is obtained for the harmonic oscillator using the path integral formulation. By using the latter, the fermionic partition function turns out to be the ratio of two determinants of the same operator (∂τ + ω), whose eigenmodes being both periodic on the imaginary time intervals [ 0 , 2 β ], [ 0 , β ]. The natural generalization of the factorization formula when β →2m β is derived, such a factorization implies that the bosonic oscillator at temperature β can be seen as a non-interacting mixture of a bosonic oscillator at temperature 2m β and m-fermionic oscillators at different temperatures 2 m - k β, k = 1 , 2 , … , m. As a consequence, a general relationship between the bosonic and fermionic thermal zeta functions is deduced.

  13. Parallel algorithms for dynamically partitioning unstructured grids

    SciTech Connect

    Diniz, P.; Plimpton, S.; Hendrickson, B.; Leland, R.

    1994-10-01

    Grid partitioning is the method of choice for decomposing a wide variety of computational problems into naturally parallel pieces. In problems where computational load on the grid or the grid itself changes as the simulation progresses, the ability to repartition dynamically and in parallel is attractive for achieving higher performance. We describe three algorithms suitable for parallel dynamic load-balancing which attempt to partition unstructured grids so that computational load is balanced and communication is minimized. The execution time of algorithms and the quality of the partitions they generate are compared to results from serial partitioners for two large grids. The integration of the algorithms into a parallel particle simulation is also briefly discussed.

  14. Ocular Counter-Rolling During Centrifugation and Static Tilt

    NASA Technical Reports Server (NTRS)

    Cohen, Bernard; Clement, Gilles; Moore, Steven; Curthoys, Ian; Dai, Mingjia; Koizuka, Izumi; Kubo, Takeshi; Raphan, Theodore

    2003-01-01

    Activation of the gravity sensors in the inner ear-the otoliths-generates reflexes that act to maintain posture and gaze. Ocular counter-rolling (OCR) is an example of such a reflex. When the head is tilted to the side, the eyes rotate around the line of sight in the opposite direction (i.e., counter-rolling). While turning comers, undergoing centrifugation, or making side-to-side tilting head movements, the OCR reflex orients the eyes towards the sum of the accelerations from body movements and gravity. Deconditioning of otolith-mediated reflexes following adaptation to microgravity has been proposed as the basis of many of the postural, locomotor, and gaze control problems experienced by returning astronauts. Evidence suggests that OCR is reduced postflight in about 75% of astronauts tested; but the data are sparse, primarily due to difficulties in recording rotational eye movements. During the Neurolab mission, a short-arm human centrifuge was flown that generated sustained sideways accelerations of 0.5-G and one-G to the head and upper body. This produces OCR; and so for the first time, the responses to sustained centrifugation could be studied without the influence of Earth's gravity on the results. This allowed us to determine the relative importance of sideways and vertical acceleration in the generation of OCR. This also provided the first test of the effects of exposure to artificial gravity in space on postflight otolith-ocular reflexes. There was little difference between the responses to centrifugation in microgravity and on Earth. In both conditions, the induced OCR was roughly proportional to the applied acceleration, with the OCR magnitude during 0.5-G centrifugation approximately 60% of that generated during one-G centrifugation. The overall mean OCR from the four payload crewmembers in response to one-G of sideways acceleration was 5.7 plus or minus 1.1 degree (mean and SD) on Earth. Inflight one-G centrifugation generated 5.7 plus or minus 1

  15. Partitioning SAT Instances for Distributed Solving

    NASA Astrophysics Data System (ADS)

    Hyvärinen, Antti E. J.; Junttila, Tommi; Niemelä, Ilkka

    In this paper we study the problem of solving hard propositional satisfiability problem (SAT) instances in a computing grid or cloud, where run times and communication between parallel running computations are limited.We study analytically an approach where the instance is partitioned iteratively into a tree of subproblems and each node in the tree is solved in parallel.We present new methods for constructing partitions which combine clause learning and lookahead. The methods are incorporated into the iterative approach and its performance is demonstrated with an extensive comparison against the best sequential solvers in the SAT competition 2009 as well as against two efficient parallel solvers.

  16. Chiral partition functions of quantum Hall droplets

    SciTech Connect

    Cappelli, Andrea Viola, Giovanni; Zemba, Guillermo R.

    2010-02-15

    Chiral partition functions of conformal field theory describe the edge excitations of isolated Hall droplets. They are characterized by an index specifying the quasiparticle sector and transform among themselves by a finite-dimensional representation of the modular group. The partition functions are derived and used to describe electron transitions leading to Coulomb blockade conductance peaks. We find the peak patterns for Abelian hierarchical states and non-Abelian Read-Rezayi states, and compare them. Experimental observation of these features can check the qualitative properties of the conformal field theory description, such as the decomposition of the Hilbert space into sectors, involving charged and neutral parts, and the fusion rules.

  17. Cochlear implant in incomplete partition type I.

    PubMed

    Berrettini, S; Forli, F; De Vito, A; Bruschini, L; Quaranta, N

    2013-02-01

    In this investigation, we report on 4 patients affected by incomplete partition type I submitted to cochlear implant at our institutions. Preoperative, surgical, mapping and follow-up issues as well as results in cases with this complex malformation are described. The cases reported in the present study confirm that cochlear implantation in patients with incomplete partition type I may be challenging for cochlear implant teams. The results are variable, but in many cases satisfactory, and are mainly related to the surgical placement of the electrode and residual neural nerve fibres. Moreover, in some cases the association of cochlear nerve abnormalities and other disabilities may significantly affect results.

  18. Liquid Chromatography in 1982.

    ERIC Educational Resources Information Center

    Freeman, David H.

    1982-01-01

    Reviews trends in liquid chromatography including apparatus, factors affecting efficient separation of a mixture (peak sharpness and speed), simplified problem-solving, adsorption, bonded phase chromatography, ion selectivity, and size exclusion. The current trend is to control chemical selectivity by the liquid phase. (Author/JN)

  19. Advanced proteomic liquid chromatography

    SciTech Connect

    Xie, Fang; Smith, Richard D.; Shen, Yufeng

    2012-10-26

    Liquid chromatography coupled with mass spectrometry is the predominant platform used to analyze proteomics samples consisting of large numbers of proteins and their proteolytic products (e.g., truncated polypeptides) and spanning a wide range of relative concentrations. This review provides an overview of advanced capillary liquid chromatography techniques and methodologies that greatly improve separation resolving power and proteomics analysis coverage, sensitivity, and throughput.

  20. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  1. Generalized linear solvation energy model applied to solute partition coefficients in ionic liquid-supercritical carbon dioxide systems.

    PubMed

    Planeta, Josef; Karásek, Pavel; Hohnová, Barbora; Sťavíková, Lenka; Roth, Michal

    2012-08-10

    Biphasic solvent systems composed of an ionic liquid (IL) and supercritical carbon dioxide (scCO(2)) have become frequented in synthesis, extractions and electrochemistry. In the design of related applications, information on interphase partitioning of the target organics is essential, and the infinite-dilution partition coefficients of the organic solutes in IL-scCO(2) systems can conveniently be obtained by supercritical fluid chromatography. The data base of experimental partition coefficients obtained previously in this laboratory has been employed to test a generalized predictive model for the solute partition coefficients. The model is an amended version of that described before by Hiraga et al. (J. Supercrit. Fluids, in press). Because of difficulty of the problem to be modeled, the model involves several different concepts - linear solvation energy relationships, density-dependent solvent power of scCO(2), regular solution theory, and the Flory-Huggins theory of athermal solutions. The model shows a moderate success in correlating the infinite-dilution solute partition coefficients (K-factors) in individual IL-scCO(2) systems at varying temperature and pressure. However, larger K-factor data sets involving multiple IL-scCO(2) systems appear to be beyond reach of the model, especially when the ILs involved pertain to different cation classes.

  2. The simulation and performance of a centrifugal chiller

    NASA Astrophysics Data System (ADS)

    Jackson, W. L.; Chen, F. C.; Hwang, B. C.

    A computer simulation model was developed to analyze the performance of a water-cooled centrifugal chiller. The model is based on a heat pump thermodynamic cycle and empirical correlations for the performance of the system components. The system simulated is composed of a variable-speed centrifugal compressor with a hot-gas bypass option for capacity control, two shell-and-tube heat exchangers, and an expansion device. The model was validated and calibrated against the experimental test results of a 125-ton chiller. The performance of a similar chiller system at various operating conditions and design modifications was analyzed. System performance comparisons were made between a baseline case, cases with high-performance heat exchanger tubes and compressor motor, and various variable-speed compressor operating strategies. It was found that significant performance improvement can be realized by using variable-speed drive and on-demand control strategy.

  3. Analysis of the reliability of submersible centrifugal electric pumping systems

    SciTech Connect

    Shilyaev, V.A.; Solodovnikov, G.G.; Vikhman, R.G.; Koshelev, V.A.; Zhitina, G.S.; Chirkova, N.I.

    1987-01-01

    A modern submersible centrifugal electric pumping system (SCEPS) for oil production consists of a submersible part which includes a centrifugal pump, an electric motor, a hydroprotection arrangement, a cable line, and an aboveground part that includes a control station and a transformer. The author discusses the mean service life of the submersible part of the SCEPS as the most important parameter of reliability of the SCEPS. The effect of the operating factors is assessed by calculating the mean service life of the submersible part of the typical SCEPS, making allowance for failures resulting from all causes. The mean operating time until failure of the submersible part of the new SCEPS due to design and technological error was determined.

  4. Core temperature of tailless rats exposed to centrifugation

    NASA Technical Reports Server (NTRS)

    Monson, C. B.; Oyama, J.

    1984-01-01

    The role of the tail in the altered thermoregulation of rats during acute exposure to hypergravity was investigated, using groups of rats of two ages: 55 days (young) and 138 days (old). Rectal and foot temperature changes were measured in intact and tailless rats subjected to 1 h centrifugation of 2.8 G, with preceding (1 h) and following (1-3 h) 1 G periods. At 22 C, the loss of body heat from the tail per se does not measurably contribute to the hypothermia induced by hypergravity. However, the heat loss from the feet was greater in the tailless rats than in the intact rats from the young group of animals, although there was no significant difference between the tailless and intact rats in the old animal group. It is concluded that the inhibition of heat production is a significant factor in the hypothermia of centrifuged tailless rats, as it has been previously shown to be in the intact animals.

  5. Optimization of centrifugal pump cavitation performance based on CFD

    NASA Astrophysics Data System (ADS)

    Xie, S. F.; Wang, Y.; Liu, Z. C.; Zhu, Z. T.; Ning, C.; Zhao, L. F.

    2015-01-01

    In order to further improve the cavitation performance of a centrifugal pump, slots on impeller blade near inlet were studied and six groups of hydraulic model were designed. Base on cavitating flow feature inside a centrifugal pump, bubble growth and implosion are calculated from the Rayleigh-Plesset equation which describes the dynamic behavior of spherical bubble and RNG κ-epsilon model was employed to simulate and analyze the internal two-phase flow of the model pump under the same conditions. The simulation results show that slots on blade near inlet could improve the cavitation performance and cavitation performance improvement of the second group was more obvious. Under the same conditions, the pressure on the back of blade near inlet was higher than the pressure on the back of unmodified blade near inlet, and energy distribution in the flow channel between the two blades was more uniform with a small change of head.

  6. Analysis of cantilever NEMS in centrifugal-fluidic systems

    NASA Astrophysics Data System (ADS)

    Mohsen-Nia, Mohsen; Abadian, Fateme; Abadian, Naeime; Dehkordi, Keivan Mosaiebi; Keivani, Maryam; Abadyan, Mohamadreza

    2016-07-01

    Electromechanical nanocantilevers are promising for using as sensors/detectors in centrifugal-fluidic systems. For this application, the presence of angular speed and electrolyte environment should be considered in the theoretical analysis. Herein, the pull-in instability of the nanocantilever incorporating the effects of angular velocity and liquid media is investigated using a size-dependent continuum theory. Using d’Alembert principle, the angular speed is transformed into an equivalent centrifugal force. The electrochemical and dispersion forces are incorporated considering the corrections due to the presence of electrolyte media. Two different approaches, i.e., the Rayleigh-Ritz method (RRM) and proposing a lumped parameter model (LPM), were applied to analyze the system. The models are validated with the results presented in literature. Impacts of the angular velocity, electrolyte media, dispersion forces, and size effect on the instability characteristics of the nanocantilever are discussed.

  7. Probing biomechanical properties with a centrifugal force quartz crystal microbalance.

    PubMed

    Webster, Aaron; Vollmer, Frank; Sato, Yuki

    2014-10-21

    Application of force on biomolecules has been instrumental in understanding biofunctional behaviour from single molecules to complex collections of cells. Current approaches, for example, those based on atomic force microscopy or magnetic or optical tweezers, are powerful but limited in their applicability as integrated biosensors. Here we describe a new force-based biosensing technique based on the quartz crystal microbalance. By applying centrifugal forces to a sample, we show it is possible to repeatedly and non-destructively interrogate its mechanical properties in situ and in real time. We employ this platform for the studies of micron-sized particles, viscoelastic monolayers of DNA and particles tethered to the quartz crystal microbalance surface by DNA. Our results indicate that, for certain types of samples on quartz crystal balances, application of centrifugal force both enhances sensitivity and reveals additional mechanical and viscoelastic properties.

  8. Reverse-Tangent Injection in a Centrifugal Compressor

    NASA Technical Reports Server (NTRS)

    Skoch, Gary J.

    2007-01-01

    Injection of working fluid into a centrifugal compressor in the reverse tangent direction has been invented as a way of preventing flow instabilities (stall and surge) or restoring stability when stall or surge has already commenced. The invention applies, in particular, to a centrifugal compressor, the diffuser of which contains vanes that divide the flow into channels oriented partly radially and partly tangentially. In reverse-tangent injection, a stream or jet of the working fluid (the fluid that is compressed) is injected into the vaneless annular region between the blades of the impeller and the vanes of the diffuser. As used here, "reverse" signifies that the injected flow opposes (and thereby reduces) the tangential component of the velocity of the impeller discharge. At the same time, the injected jet acts to increase the radial component of the velocity of the impeller discharge.

  9. Improved Monodispersity of Plasmonic Nanoantennas via Centrifugal Processing

    SciTech Connect

    Tyler, Timothy P.; Henry, A.I.; Van Duyne, Richard P.; Hersam, Mark C.

    2011-02-03

    Noble metal nanoparticle clusters underlie a variety of plasmonic devices and measurements including surface-enhanced Raman spectroscopy (SERS). Because of the strong dependence of plasmonic properties on nanoparticle cluster aggregation state, the elimination of non-SERS-active structures and the refinement of the nanoparticle cluster population are critical to realizing uniform and reproducible structures for plasmonic nanoantenna applications such as SERS-based sensors. In this Letter, we report a centrifugal sorting technique for gold core/silica shell nanoparticles that host SERS reporter molecules at the gold/silica interface. The relatively massive nanoparticle clusters are sorted by sedimentation coefficient via centrifugation in a high-viscosity density gradient medium, iodixanol, which yields solutions that contain a preponderance of one aggregation state and a diminished monomer population, as determined by transmission electron microscopy, extinction spectroscopy, and SERS. A quantitative analysis of the nanoparticle sedimentation coefficients is presented, thus allowing this approach to be predictably generalized to other nanoparticle systems.

  10. Hemocompatibility of a hydrodynamic levitation centrifugal blood pump.

    PubMed

    Yamane, Takashi; Maruyama, Osamu; Nishida, Masahiro; Kosaka, Ryo; Sugiyama, Daisuke; Miyamoto, Yusuke; Kawamura, Hiroshi; Kato, Takahisa; Sano, Takeshi; Okubo, Takeshi; Sankai, Yoshiyuki; Shigeta, Osamu; Tsutsui, Tatsuo

    2007-01-01

    A noncontact type centrifugal pump without any complicated control or sensing modules has been developed as a long-term implantable artificial heart. Centrifugal pumps with impellers levitated by original hydrodynamic bearings were designed and have been modified through numerical analyses and in vitro tests. The hemolysis level was reduced by changing the pressure distribution around the impeller and subsequently expanding the bearing gap. Thrombus formation in the bearing was examined with in vitro thrombogenesis tests and was reduced by changing the groove shapes to increase the bearing-gap flow to 3% of the external flow. Unnecessary vortices around the vanes were also eliminated by changing the number of vanes from four to six.

  11. Determination of Free-Energy Relationships Using Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Snow, Nicholas H.

    1996-06-01

    By performing a few straightforward analyses on a gas chromatograph, it is possible to calculate the free energy, enthalpy, and entropy changes that occur when a compound transfers between the mobile and stationary phases. The partition theory of chromatography allows this transfer to be expressed as a chemical equlibrium. By calculating the equilibrium constant for this reaction from chromatographic retention times, the standard free energy change may be determined, and from this, the standard enthalpy and entropy changes. Also, by calculating these values at several temperatures for structurally related compounds, it is possible to explore the relationship between chromatographic retention, standard free energy, and the structure of a compound. These calculations were performed for groups of homologous alcohols, acetates, and hydrocarbons on packed and capillary column gas chromatographs, using both polar and non-polar columns, and on computer simulation software. It is seen that for homologous compounds, the relationship between standard free energy change in partitioning and hydrocarbon chain length for this reaction is linear. It is also seen that gas chromatography represents a useful tool for the calculation and comparison of thermodynamic properties of compounds and that straightforward exercise of this type allows training of students in chromatographic analysis, basic partition theory, thermodynamic relationships, and linear free energy relationships.

  12. Partitioning and lipophilicity in quantitative structure-activity relationships.

    PubMed Central

    Dearden, J C

    1985-01-01

    The history of the relationship of biological activity to partition coefficient and related properties is briefly reviewed. The dominance of partition coefficient in quantitation of structure-activity relationships is emphasized, although the importance of other factors is also demonstrated. Various mathematical models of in vivo transport and binding are discussed; most of these involve partitioning as the primary mechanism of transport. The models describe observed quantitative structure-activity relationships (QSARs) well on the whole, confirming that partitioning is of key importance in in vivo behavior of a xenobiotic. The partition coefficient is shown to correlate with numerous other parameters representing bulk, such as molecular weight, volume and surface area, parachor and calculated indices such as molecular connectivity; this is especially so for apolar molecules, because for polar molecules lipophilicity factors into both bulk and polar or hydrogen bonding components. The relationship of partition coefficient to chromatographic parameters is discussed, and it is shown that such parameters, which are often readily obtainable experimentally, can successfully supplant partition coefficient in QSARs. The relationship of aqueous solubility with partition coefficient is examined in detail. Correlations are observed, even with solid compounds, and these can be used to predict solubility. The additive/constitutive nature of partition coefficient is discussed extensively, as are the available schemes for the calculation of partition coefficient. Finally the use of partition coefficient to provide structural information is considered. It is shown that partition coefficient can be a valuable structural tool, especially if the enthalpy and entropy of partitioning are available. PMID:3905374

  13. Equivalence of partition properties and determinacy

    PubMed Central

    Kechris, Alexander S.; Woodin, W. Hugh

    1983-01-01

    It is shown that, within L(ℝ), the smallest inner model of set theory containing the reals, the axiom of determinacy is equivalent to the existence of arbitrarily large cardinals below Θ with the strong partition property κ → (κ)κ. PMID:16593299

  14. Mapping Pesticide Partition Coefficients By Electromagnetic Induction

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A potential method for reducing pesticide leaching is to base application rates on the leaching potential of a specific chemical and soil combination. However, leaching is determined in part by the partitioning of the chemical between the soil and soil solution, which varies across a field. Standard...

  15. Solute partitioning and filtration by extracellular matrices

    PubMed Central

    Hofmann, Christina L.; Ferrell, Nicholas; Schnell, Lisa; Dubnisheva, Anna; Zydney, Andrew L.; Yurchenco, Peter D.; Roy, Shuvo

    2009-01-01

    The physiology of glomerular filtration remains mechanistically obscure despite its importance in disease. The correspondence between proteinuria and foot process effacement suggests podocytes as the locus of the filtration barrier. If so, retained macromolecules ought to accumulate at the filtration barrier, an effect called concentration polarization. Literature data indicate macromolecule concentrations decrease from subendothelial to subepithelial glomerular basement membrane (GBM), as would be expected if the GBM were itself the filter. The objective of this study was to obtain insights into the possible role of the GBM in protein retention by performing fundamental experimental and theoretical studies on the properties of three model gels. Solute partitioning and filtration through thin gels of a commercially available laminin-rich extracellular matrix, Matrigel, were measured using a polydisperse polysaccharide tracer molecule, Ficoll 70. Solute partitioning into laminin gels and lens basement membrane (LBM) were measured using Ficoll 70. A novel model of a laminin gel was numerically simulated, as well as a mixed structure-random-fiber model for LBM. Experimental partitioning was predicted by numerical simulations. Sieving coefficients through thin gels of Matrigel were size dependent and strongly flux dependent. The observed flux dependence arose from compression of the gel in response to the applied pressure. Gel compression may alter solute partitioning into extracellular matrix at physiologic pressures present in the glomerular capillary. This suggests a physical mechanism coupling podocyte structure to permeability characteristics of the GBM. PMID:19587146

  16. A review of approaches for evapotranspiration partitioning

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Partitioning of evapotranspiration (ET) into evaporation from the soil surface (E) and transpiration (T) is challenging but important in order to assess biomass production and the allocation of increasingly scarce water resources. Generally T is the desired component with the water being used to enh...

  17. A Partition Formula for Fibonacci Numbers

    NASA Astrophysics Data System (ADS)

    Fahr, Philipp; Ringerl, Claus Michael

    2008-02-01

    We present a partition formula for the even index Fibonacci numbers. The formula is motivated by the appearance of these Fibonacci numbers in the representation theory of the socalled 3-Kronecker quiver, i.e., the oriented graph with two vertices and three arrows in the same direction.

  18. 25 CFR 152.33 - Partition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER ISSUANCE OF PATENTS IN FEE, CERTIFICATES OF COMPETENCY, REMOVAL OF RESTRICTIONS, AND SALE OF CERTAIN INDIAN LANDS Partitions in Kind of Inherited Allotments § 152..., regardless of their competency, patents in fee to be issued to the competent heirs for their shares and...

  19. 25 CFR 152.33 - Partition.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER ISSUANCE OF PATENTS IN FEE, CERTIFICATES OF COMPETENCY, REMOVAL OF RESTRICTIONS, AND SALE OF CERTAIN INDIAN LANDS Partitions in Kind of Inherited Allotments § 152..., regardless of their competency, patents in fee to be issued to the competent heirs for their shares and...

  20. 25 CFR 152.33 - Partition.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER ISSUANCE OF PATENTS IN FEE, CERTIFICATES OF COMPETENCY, REMOVAL OF RESTRICTIONS, AND SALE OF CERTAIN INDIAN LANDS Partitions in Kind of Inherited Allotments § 152..., regardless of their competency, patents in fee to be issued to the competent heirs for their shares and...

  1. 25 CFR 152.33 - Partition.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER ISSUANCE OF PATENTS IN FEE, CERTIFICATES OF COMPETENCY, REMOVAL OF RESTRICTIONS, AND SALE OF CERTAIN INDIAN LANDS Partitions in Kind of Inherited Allotments § 152..., regardless of their competency, patents in fee to be issued to the competent heirs for their shares and...

  2. 25 CFR 152.33 - Partition.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER ISSUANCE OF PATENTS IN FEE, CERTIFICATES OF COMPETENCY, REMOVAL OF RESTRICTIONS, AND SALE OF CERTAIN INDIAN LANDS Partitions in Kind of Inherited Allotments § 152..., regardless of their competency, patents in fee to be issued to the competent heirs for their shares and...

  3. Set Partitions and the Multiplication Principle

    ERIC Educational Resources Information Center

    Lockwood, Elise; Caughman, John S., IV

    2016-01-01

    To further understand student thinking in the context of combinatorial enumeration, we examine student work on a problem involving set partitions. In this context, we note some key features of the multiplication principle that were often not attended to by students. We also share a productive way of thinking that emerged for several students who…

  4. Zr partitioning and kinetics and mechanism

    NASA Technical Reports Server (NTRS)

    Taylor, L. A.

    1973-01-01

    The results of investigations concerning the cooling histories of lunar rocks are reported. Publications resulting from this research are listed. Studies discussed include the partitioning of Zr between FeTi03 and Fe2Ti04 in the presence of Fe + Zr02, and ulvospinel reduction.

  5. Application of partition technology to particle electrophoresis

    NASA Technical Reports Server (NTRS)

    Van Alstine, James M.; Harris, J. Milton; Karr, Laurel J.; Bamberger, Stephan; Matsos, Helen C.; Snyder, Robert S.

    1989-01-01

    The effects of polymer-ligand concentration on particle electrophoretic mobility and partition in aqueous polymer two-phase systems are investigated. Polymer coating chemistry and affinity ligand synthesis, purification, and analysis are conducted. It is observed that poly (ethylene glycol)-ligands are effective for controlling particle electrophoretic mobility.

  6. A Large Radius Human Centrifuge: The Human Hypergravity Havitat

    NASA Astrophysics Data System (ADS)

    van Loon, J. J. W. A.

    2008-06-01

    Life on Earth has developed at unit gravity, 9.81 m/s2, but how would plants and animals have evolved on a larger planet, i.e. larger than Earth? We are able to address this question simply by studies using centrifuges. In the past decades numerous experiments have been performed on cells, plants and animals grown for longer durations, even multi generations, under hypergravity conditions. Based on these studies we have gained interesting insights in the physiological process of these systems when exposed to artificial gravity. Animals and plants adapt themselves to this new high-g environment. Information of adaptation to hyper-g in mammals is interesting, or maybe even proof vital, for future human space flight programs especially in light of long duration missions to Moon and Mars. We know from long duration animal studies that numerous physiological processes and structures like muscles, bones, neuro-vestibular, or the cardiovascular system are affected. However, humans have never been exposed to a hyper-g environment for long durations. Human studies are mostly in the order of hours at most. Current work on human centrifuges is all focused on short arm systems to apply artificial gravity in long duration space missions. In this paper we want to address the possible usefulness of a large radius human centrifuge on Earth, or even on Moon or Mars, for both basic research and possible applications. In such a centrifuge a group of humans may be exposed to hypergravity for, in principle, an unlimited period of time.

  7. Comparative hemolysis study of clinically available centrifugal pumps.

    PubMed

    Naito, K; Suenaga, E; Cao, Z L; Suda, H; Ueno, T; Natsuaki, M; Itoh, T

    1996-06-01

    Centrifugal pumps have become important devices for cardiopulmonary bypass and circulatory assistance. Five types of centrifugal pumps are clinically available in Japan. To evaluate the blood trauma caused by centrifugal pumps, a comparative hemolysis study was performed under identical conditions. In vitro hemolysis test circuits were constructed to operate the BioMedicus BP-80 (Medtronic, BioMedicus), Sarns Delphin (Sarns/3M Healthcare), Isoflow (St. Jude Medical [SJM]), HPM-15 (Nikkiso), and Capiox CX-SP45 (Terumo). The hemolysis test loop consisted of two 1.5 m lengths of polyvinyl chloride tubing with a 3/8-inch internal diameter, a reservoir with a sampling port, and a pump head. All pumps were set to flow at 6 L/min against the total pressure head of 120 mm Hg. Experiments were conducted simultaneously for 6 h at room temperature (21 degrees C) with fresh bovine blood. Blood samples for plasma-free hemoglobin testing were taken, and the change in temperature at the pump outlet port was measured during the experiment. The mean pump rotational speeds were 1,570, 1,374, 1,438, 1,944, and 1,296 rpm, and the normalized indexes of hemolysis were 0.00070, 0.00745, 0.00096, 0.00066, 0.00090 g/100 L for the BP-80, Sarns, SJM, Nikkiso, and Terumo pumps, respectively. The change in temperature at the pump outlet port was the least for the Nikkiso pump (1.8 degrees C) and the most with the SJM pump (3.8 degrees C). This study showed that there is no relationship between the pump rotational speed (rpm) and the normalized index of hemolysis in 5 types of centrifugal pumps. The pump design and number of impellers could be more notable factors in blood damage.

  8. At 1050 Gallery, Block 12, two centrifugal pumps, Buffalo Pumps, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    At 1050 Gallery, Block 12, two centrifugal pumps, Buffalo Pumps, Buffalo, NY, driven by Allis Chalmers motors (size 3 HSO, head 230, 120 cpm, 1750, rpm, Impulse dia. 15) installed in the 1960s and used for water-cooling system for 230-kv cable; the cables have been removed and the pumps are not currently used. - Columbia Basin Project, Grand Coulee Dam & Franklin D. Roosevelt Lake, Across Columbia River, Southeast of Town of Grand Coulee, Grand Coulee, Grant County, WA

  9. Liquid rocket engine centrifugal flow turbopumps. [design criteria

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Design criteria and recommended practices are discussed for the following configurations selected from the design sequence of a liquid rocket engine centrifugal flow turbopump: (1) pump performance including speed, efficiency, and flow range; (2) impeller; (3) housing; and (4) thrust balance system. Hydrodynamic, structural, and mechanical problems are addressed for the achievement of required pump performance within the constraints imposed by the engine/turbopump system. Materials and fabrication specifications are also discussed.

  10. Conditions to obtain reliable high strength alumina via centrifugal casting

    SciTech Connect

    Huisman, W.; Graule, T.; Gauckler, L.J.

    1995-09-01

    Electrostatically stabilized alumina suspensions with high solids content of up to 58 vol% were consolidated into near-net-shape parts via centrifugal casting. High density green bodies showed excellent sintering kinetics leading to {ge} 99.5% of theoretical density (TD) at lowered temperatures compared to isostatic pressing. Four point bend strengths of 540 MPa with Weibull moduli of up to 24 were achieved using commercial {alpha}-alurnina powders.

  11. Laser tracker TSPI uncertainty quantification via centrifuge trajectory

    NASA Astrophysics Data System (ADS)

    Romero, Edward; Paez, Thomas; Brown, Timothy; Miller, Timothy

    2009-08-01

    Sandia National Laboratories currently utilizes two laser tracking systems to provide time-space-position-information (TSPI) and high speed digital imaging of test units under flight. These laser trackers have been in operation for decades under the premise of theoretical accuracies based on system design and operator estimates. Advances in optical imaging and atmospheric tracking technology have enabled opportunities to provide more precise six degree of freedom measurements from these trackers. Applying these technologies to the laser trackers requires quantified understanding of their current errors and uncertainty. It was well understood that an assortment of variables contributed to laser tracker uncertainty but the magnitude of these contributions was not quantified and documented. A series of experiments was performed at Sandia National Laboratories large centrifuge complex to quantify TSPI uncertainties of Sandia National Laboratories laser tracker III. The centrifuge was used to provide repeatable and economical test unit trajectories of a test-unit to use for TSPI comparison and uncertainty analysis. On a centrifuge, testunits undergo a known trajectory continuously with a known angular velocity. Each revolution may represent an independent test, which may be repeated many times over for magnitudes of data practical for statistical analysis. Previously these tests were performed at Sandia's rocket sled track facility but were found to be costly with challenges in the measurement ground truth TSPI. The centrifuge along with on-board measurement equipment was used to provide known ground truth position of test units. This paper discusses the experimental design and techniques used to arrive at measures of laser tracker error and uncertainty.

  12. Centrifugal Blower for Personal Air Ventilation System (PAVS) - Phase 1

    DTIC Science & Technology

    2015-02-01

    axial blower design was chosen to achieve the highest possible efficiency within the size constraints of the system. The blower is able to deliver 10...of the blower were used to minimize losses and increase efficiency through adjustments of the specific blower geometry. CFD outputs included the...functionality. 15. SUBJECT TERMS COOLING SBIR REPORTS AXIAL FLOW FANS OFF THE SHELF EQUIPMENT BLOWERS LIGHTWEIGHT CENTRIFUGAL FORCE

  13. Human Disorientation as a Factor in Spacecraft Centrifuge Design

    DTIC Science & Technology

    2002-09-01

    from the rotation of the 58 J.L. Meriam and L.G. Kraige, Engineering Mechanics Vol. 2: Dynamics, 2nd Edition, New York: John Wiley and Sons, 1986...McGraw-Hill, 1983, p. 39 60 Meriam and Kraige, Dynamics, p. 350 61 Wells and Slusher, p. 64 102 centrifuge). This force appears as either an...64 Milsum, p. 187 65 Meriam and Kraige, Dynamics, p. 630 66 Meriam and Kraige, Engineering Mechanics Vol. 1

  14. Homogeneous enzyme immunoassay (EMIT) protocol for monitoring tricyclic antidepressants on the COBAS-BIO centrifugal analyzer.

    PubMed

    Ernst, R; Williams, L; Dalbey, M; Collins, C; Pankey, S

    1987-01-01

    EMIT tests are available for quantitative determination of the tricyclic antidepressants amitriptyline (AMI), nortriptyline (NORT), imipramine (IMI), and desipramine (DMI). An extraction step before analysis eliminates cross-reacting polar metabolites. Excellent correlation between EMIT and high-performance liquid chromatography (HPLC) has been previously established. Most published protocols for using EMIT reagents on COBAS-BIO centrifugal analyzers were designed for analytes present at 1-50 mg/L in serum. AMI, NORT, IMI, and DMI are usually present at far less than 1 mg/L. We describe a COBAS-BIO EMIT protocol for assaying these analytes. Patient sample correlation between COBAS-BIO EMIT and EMIT-AutoLab were greater than 0.99. Between-run precision for single-point determinations was comparable to SYVA AutoLab performance [less than or equal to 11% at 40 micrograms/L AMI, NORT, IMI (80 micrograms/L DMI), and less than or equal to 4% at 200 micrograms/L AMI, NORT, IMI (400 micrograms/L DMI)]. With stored-curve updating, working reagents were usable for at least 14 days (AMI) or 23 days (DMI).

  15. Prenatal centrifugation: A model for fetal programming of adult weight?

    NASA Astrophysics Data System (ADS)

    Baer, Lisa A.; Rushing, Linda; Wade, Charles E.; Ronca, April E.

    2005-08-01

    'Fetal programming' is a newly emerging field that is revealing astounding insights into the prenatal origins of adult disease, including metabolic, endocrine, and cardiovascular pathophysiology. In the present study, we tested the hypothesis that rat pups conceived, gestated and born at 2-g have significantly reduced birth weights and increased adult body weights as compared to 1-g controls. Offspring were produced by mating young adult male and female rats that were adapted to 2-g centrifugation. Female rats underwent conception, pregnancy and birth at 2-g. Newborn pups in the 2-g condition were removed from the centrifuge and fostered to non-manipulated, newly parturient dams maintained at 1-g. Comparisons were made with 1-g stationary controls, also cross- fostered at birth. As compared to 1-g controls, birth weights of pups gestated and born at 2-g were significantly reduced. Pup body weights were significantly reduced until Postnatal day (P)12. Beginning on P63, body weights of 2-g-gestated offspring exceeded those of 1-g controls by 7-10%. Thus, prenatal rearing at 2-g restricts neonatal growth and increases adult body weight. Collectively, these data support the hypothesis that 2-g centrifugation alters the intrauterine milieu, thereby inducing persistent changes in adult phenotype.

  16. Massively Parallel Single-Molecule Manipulation Using Centrifugal Force

    NASA Astrophysics Data System (ADS)

    Wong, Wesley; Halvorsen, Ken

    2011-03-01

    Precise manipulation of single molecules has led to remarkable insights in physics, chemistry, biology, and medicine. However, two issues that have impeded the widespread adoption of these techniques are equipment cost and the laborious nature of making measurements one molecule at a time. To meet these challenges, we have developed an approach that enables massively parallel single- molecule force measurements using centrifugal force. This approach is realized in the centrifuge force microscope, an instrument in which objects in an orbiting sample are subjected to a calibration-free, macroscopically uniform force- field while their micro-to-nanoscopic motions are observed. We demonstrate high- throughput single-molecule force spectroscopy with this technique by performing thousands of rupture experiments in parallel, characterizing force-dependent unbinding kinetics of an antibody-antigen pair in minutes rather than days. Currently, we are taking steps to integrate high-resolution detection, fluorescence, temperature control and a greater dynamic range in force. With significant benefits in efficiency, cost, simplicity, and versatility, single-molecule centrifugation has the potential to expand single-molecule experimentation to a wider range of researchers and experimental systems.

  17. Low-molecular weight plasma proteome analysis using centrifugal ultrafiltration.

    PubMed

    Greening, David W; Simpson, Richard J

    2011-01-01

    The low-molecular weight fraction (LMF) of the human plasma proteome is an invaluable source of biological information, especially in the context of identifying plasma-based biomarkers of disease. This protocol outlines a standardized procedure for the rapid/reproducible LMF profiling of human plasma samples using centrifugal ultrafiltration fractionation, followed by 1D-SDS-PAGE separation and nano-LC-MS/MS. Ultrafiltration is a convective process that uses anisotropic semipermeable membranes to separate macromolecular species on the basis of size. We have optimized centrifugal ultrafiltration for plasma fractionation with respect to buffer and solvent composition, centrifugal force, duration and temperature to facilitate >95% recovery, and enrichment of low-M (r) components from human plasma. Using this protocol, >260 unique peptides can be identified from a single plasma profiling experiment using 100 μL of plasma (Greening and Simpson, J Proteomics 73:637-648, 2010). The efficacy of this method is demonstrated by the identification, for the first time, of several plasma proteins (e.g., protein KIAA0649 (Q9Y4D3), rheumatoid factor D5, serine protease inhibitor A3, and transmembrane adapter protein PAG) previously not reported in extant high-confidence Human Proteome Organization Plasma Proteome Project datasets.

  18. Stress analysis of bolted joints under centrifugal force

    NASA Astrophysics Data System (ADS)

    Imura, Makoto; Iizuka, Motonobu; Nakae, Shigeki; Mori, Takeshi; Koyama, Takayuki

    2014-06-01

    Our objective is to develop a long-life rotary machine for synchronous generators and motors. To do this, it is necessary to design a high-strength bolted joint, which is responsible for fixing a salient pole on a rotor shaft. While the rotary machine is in operation, not only centrifugal force but also moment are loaded on a bolted joint, because a point of load is eccentric to a centre of a bolt. We tried to apply the theory proposed in VDI2230-Blatt1 to evaluate the bolted joint under eccentric force, estimate limited centrifugal force, which is the cause of partial separation between the pole and the rotor shaft, and then evaluate additional tension of a bolt after the partial separation has occurred. We analyzed the bolted joint by FEM, and defined load introduction factor in that case. Additionally, we investigated the effect of the variation of bolt preload on the partial separation. We did a full scale experiment with a prototype rotor to reveal the variation of bolt preload against tightening torque. After that, we verified limited centrifugal force and the strength of the bolted joint by the VDI2230-Blatt1 theory and FEM considering the variation of bolt preload. Finally, we could design a high-strength bolted joint verified by the theoretical study and FEM analysis.

  19. Modelling of horizontal centrifugal casting of work roll

    NASA Astrophysics Data System (ADS)

    Xu, Zhian; Song, Nannan; Tol, Rob Val; Luan, Yikun; Li, Dianzhong

    2012-07-01

    A numerical model to simulate horizontal centrifugal roll castings is presented in this paper. In order to simulate the flow fluid and solidification of horizontal centrifugal roll casting correctly, the model uses a body fitted mesh technique to represent the geometry. This new method maps a plate layer mesh to a circular mesh. The smooth body fitted mesh method gives more accurate calculation results for cylindrical geometries. A velocity depending on the angular velocity and inner radius of the mould is set up as a velocity boundary condition. The fluid flow coupled with heat transfer and solidification in a rapidly rotating roll is simulated. A gravity free falling method is applied as a pouring condition. A moveable pouring system is also used in the simulations. High speed steel is used to produce the work roll. Two different gating positions and a moveable gating system are simulated in this paper. Results show that the position of pouring system has a significant influence on the temperature distribution. The temperature distribution at a fixed central pouring system is more favourable than the distribution from a side pouring system. A moving gating system method is a better way to obtain a uniform temperature field in centrifugal casting and offers an alternative for existing techniques.

  20. Centrifuge: rapid and sensitive classification of metagenomic sequences

    PubMed Central

    Song, Li; Breitwieser, Florian P.

    2016-01-01

    Centrifuge is a novel microbial classification engine that enables rapid, accurate, and sensitive labeling of reads and quantification of species on desktop computers. The system uses an indexing scheme based on the Burrows-Wheeler transform (BWT) and the Ferragina-Manzini (FM) index, optimized specifically for the metagenomic classification problem. Centrifuge requires a relatively small index (4.2 GB for 4078 bacterial and 200 archaeal genomes) and classifies sequences at very high speed, allowing it to process the millions of reads from a typical high-throughput DNA sequencing run within a few minutes. Together, these advances enable timely and accurate analysis of large metagenomics data sets on conventional desktop computers. Because of its space-optimized indexing schemes, Centrifuge also makes it possible to index the entire NCBI nonredundant nucleotide sequence database (a total of 109 billion bases) with an index size of 69 GB, in contrast to k-mer-based indexing schemes, which require far more extensive space. PMID:27852649