Weng, Tsai-Lung; Cheng, An; Chao, Sao-Jeng; Hsu, Hui-Mi
2018-01-01
This study aims to investigate the effect of adding circulating fluidized bed combustion (CFBC) ash, desulfurization slag, air-cooled blast-furnace slag and coal bottom ash to the controlled low-strength material (CLSM). Test methods include slump flow test, ball drop test, water soluble chloride ion content measurement, compressive strength and length change measurement. The results show that (1) the use of CFBC hydration ash with desulfurization slag of slump flow is the best, and the use of CFBC hydration ash with coal bottom ash and slump flow is the worst; (2) CFBC hydration ash with desulfurization slag and chloride ion content is the highest; (3) 24 h ball drop test (diameter ≤ 76 mm), and test results are 70 mm to 76 mm; (4) CFBC hydration ash with desulfurization slag and compression strength is the highest, with the coal bottom ash being the lowest; increase of CFBC hydration ash can reduce compressive strength; and (5) the water-quenched blast furnace slag and CFBC hydration ash would expand, which results in length changes of CLSM specimens. PMID:29724055
Use of circulating-fluidized-bed combustors in compressed-air energy storage systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakhamkin, M.; Patel, M.
1990-07-01
This report presents the result of a study conducted by Energy Storage and Power Consultants (ESPC), with the objective to develop and analyze compressed air energy storage (CAES) power plant concepts which utilize coal-fired circulating fluidized bed combustors (CFBC) for heating air during generating periods. The use of a coal-fired CFBC unit for indirect heating of the compressed air, in lieu of the current turbomachinery combustors, would eliminate the need for expensive premium fuels by a CAES facility. The CAES plant generation heat rate is approximately one-half of that for a conventional steam condensing power plant. Therefore, the required CFBCmore » heat generation capacity and capital costs would be lower per kW of power generation capacity. Three CAES/CFBC concepts were identified as the most promising, and were optimized using specifically developed computerized procedures. These concepts utilize various configurations of reheat turbomachinery trains specifically developed for CAES application as parts of the integrated CAES/CFBC plant concepts. The project team concluded that the optimized CAES/CFBC integrated plant concepts present a potentially attractive alternative to conventional steam generation power plants using CFBC or pulverized coal-fired boilers. A comparison of the results from the economic analysis performed on three concepts suggests that one of them (Concept 3) is the preferred concept. This concept has a two shaft turbomachinery train arrangement, and provides for load management functions by the compressor-electric motor train, and continuous base load operation of the turboexpander-electric generator train and the CFBC unit. 6 refs., 30 figs., 14 tabs.« less
EERC pilot-scale CFBC evaluation facility Project CFB test results. Topical report, Task 7.30
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mann, M.D.; Hajicek, D.R.; Henderson, A.K.
Project CFB was initiated at the University of North Dakota Energy and Environmental Research Center (EERC) in May 1988. Specific goals of the project were to (1) construct a circulating fluidized-bed combustor (CFBC) facility representative of the major boiler vendors` designs with the capability of producing scalable data, (2) develop a database for use in making future evaluations of CFBC technology, and (3) provide a facility for evaluating fuels, free of vendor bias for use in the - energy industry. Five coals were test-burned in the 1-MWth unit: North Dakota and Asian lignites, a Wyoming subbituminous, and Colorado and Pennsylvaniamore » bituminous coats. A total of 54 steady-state test periods were conducted, with the key test parameters being the average combustor temperature, excess air, superficial gas velocity, calcium-to-sulfur molar ratio, and the primary air-to-secondary air split. The capture for a coal fired in a CFBC is primarily dependent upon the total alkali-to-sulfur ratio. The required alkali-to ratio for 90% sulfur retention ranged from 1.4 to 4.9, depending upon coal type. While an alkali-to-ratio of 4.9 was required to meet 90% sulfur retention for the Salt Creek coal versus 1.4 for the Asian lignite, the total amount of sorbent addition required is much less for the Salt Creek coal, 4.2 pound sorbent per million Btu coal input, versus 62 pound/million Btu for the Asian lignite. The bituminous coals tested show optimal capture at combustor temperatures of approximately 1550{degree}F, with low-rank coals having optimal sulfur capture approximately 100{degree}F lower.« less
EERC pilot-scale CFBC evaluation facility Project CFB test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mann, M.D.; Hajicek, D.R.; Henderson, A.K.
Project CFB was initiated at the University of North Dakota Energy and Environmental Research Center (EERC) in May 1988. Specific goals of the project were to (1) construct a circulating fluidized-bed combustor (CFBC) facility representative of the major boiler vendors' designs with the capability of producing scalable data, (2) develop a database for use in making future evaluations of CFBC technology, and (3) provide a facility for evaluating fuels, free of vendor bias for use in the - energy industry. Five coals were test-burned in the 1-MWth unit: North Dakota and Asian lignites, a Wyoming subbituminous, and Colorado and Pennsylvaniamore » bituminous coats. A total of 54 steady-state test periods were conducted, with the key test parameters being the average combustor temperature, excess air, superficial gas velocity, calcium-to-sulfur molar ratio, and the primary air-to-secondary air split. The capture for a coal fired in a CFBC is primarily dependent upon the total alkali-to-sulfur ratio. The required alkali-to ratio for 90% sulfur retention ranged from 1.4 to 4.9, depending upon coal type. While an alkali-to-ratio of 4.9 was required to meet 90% sulfur retention for the Salt Creek coal versus 1.4 for the Asian lignite, the total amount of sorbent addition required is much less for the Salt Creek coal, 4.2 pound sorbent per million Btu coal input, versus 62 pound/million Btu for the Asian lignite. The bituminous coals tested show optimal capture at combustor temperatures of approximately 1550[degree]F, with low-rank coals having optimal sulfur capture approximately 100[degree]F lower.« less
Design assessment of a 150 kWt CFBC Test Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batu, A.; Selcuk, N.; Kulah, G.
2010-04-15
For clean and efficient energy generation from coal, the most suitable technology known to date is 'Fluidized Bed Combustion' technology. Applications of circulating fluidized bed (CFB) combustion technology have been steadily increasing in both capacity and number over the past decade. Designs of these units have been based on the combustion tests carried out in pilot scale facilities to determine the combustion and desulfurization characteristics of coal and limestone reserves in CFB conditions. Similarly, utilization of Turkish lignites in CFB boilers necessitates adaptation of CFB combustion technology to these resources. However, the design of these test units are not basedmore » on firing coals with high ash, volatile matter and sulfur contents like Turkish lignites. For this purpose, a 150 kWt CFB combustor test unit is designed and constructed in Chemical Engineering Department of Middle East Technical University, based on the extensive experience acquired at the existing 0.3 MWt Bubbling Atmospheric Fluidized Bed Combustor (AFBC) Test Rig. Following the commissioning tests, a combustion test is carried out for investigation of combustion characteristics of Can lignite in CFB conditions and for assessment of the design of test unit. Comparison of the design outputs with experimental results reveals that most of the predictions and assumptions have acceptable agreement with the operating conditions. In conclusion, the performance of 150 kWt CFBC Test Unit is found to be satisfactory to be utilized for the long term research studies on combustion and desulfurization characteristics of indigenous lignite reserves in circulating fluidized bed combustors. (author)« less
Cost and performance of coal-based energy in Brazil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Temchin, J.; DeLallo, M.R.
1998-07-01
As part of the US Department of Energy's (DOE) efforts to establish the strategic benefits of Clean Coal Technologies (CCT), there is a need to evaluate the specific market potential where coal is a viable option. One such market is Brazil, where significant growth in economic development requires innovative and reliable technologies to support the use of domestic coal. While coal is Brazil's most abundant and economic fossil energy resource, it is presently under utilized in the production of electrical power. This report presents conceptual design for pulverized coal (PC) and circulating fluidized-bed combustion (CFBC) options with resulting capital, operatingmore » and financial parameters based on Brazil application conditions. Recent PC and CFBC plant capital costs have dropped with competition in the generation market and have established a competitive position in power generation. Key issues addressed in this study include: Application of market based design approach for FBC and PC, which is competitive within the current domestic, and international power generation markets. Design, fabrication, purchase, and construction methods which reduce capital investment while maintaining equipment quality and plant availability. Impact on coast and performance from application of Brazilian coals, foreign trade and tax policies, construction logistics, and labor requirements. Nominal production values of 200 MWe and 400 MWe were selected for the CFBC power plant and 400 MWe for the PC. The 400 MWe size was chosen to be consistent with the two largest Brazilian PC units. Fluidized bed technology, with limited experience in single units over 200 MW, would consist of two 200 MWe circulating fluidized bed boilers supplying steam to one steam turbine for the 400 MWe capacity. A 200 MWe capacity unit was also developed for CFBC option to support opportunities in re-powering and where specific site or other infrastructure constraints limit production.« less
JV Task 108 - Circulating Fluidized-Bed Combustion and Combustion Testing of Turkish Tufanbeyli Coal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Douglas Hajicek; Jay Gunderson; Ann Henderson
2007-08-15
Two combustion tests were performed at the Energy & Environmental Research Center (EERC) using Tufanbeyli coal from Turkey. The tests were performed in a circulating fluidized-bed combustor (CFBC) and a pulverized coal-fired furnace, referred to as the combustion test facility (CTF). One of the goals of the project was to determine the type of furnace best suited to this coal. The coal is high in moisture, ash, and sulfur and has a low heating value. Both the moisture and the sulfur proved problematic for the CTF tests. The fuel had to be dried to less than 37% moisture before itmore » could be pulverized and further dried to about 25% moisture to allow more uniform feeding into the combustor. During some tests, water was injected into the furnace to simulate the level of flue gas moisture had the fuel been fed without drying. A spray dryer was used downstream of the baghouse to remove sufficient sulfur to meet the EERC emission standards permitted by the North Dakota Department of Health. In addition to a test matrix varying excess air, burner swirl, and load, two longer-term tests were performed to evaluate the fouling potential of the coal at two different temperatures. At the lower temperature (1051 C), very little ash was deposited on the probes, but deposition did occur on the walls upstream of the probe bank, forcing an early end to the test after 2 hours and 40 minutes of testing. At the higher temperature (1116 C), ash deposition on the probes was significant, resulting in termination of the test after only 40 minutes. The same coal was burned in the CFBC, but because the CFBC uses a larger size of material, it was able to feed this coal at a higher moisture content (average of 40.1%) compared to the CTF (ranging from 24.2% to 26.9%). Sulfur control was achieved with the addition of limestone to the bed, although the high calcium-to-sulfur rate required to reduce SO{sub 2} emissions resulted in heat loss (through limestone calcination) and additional ash handling. A more efficient downstream sulfur scrubber capable of operation at a much lower Ca/S ratio would result in significantly higher boiler efficiency for this coal. At the operating temperature of a typical CFBC, bed agglomeration and convective pass fouling are not likely to be significant problems with this fuel. Compared to pulverized coal-firing, CFBC technology is clearly the better choice for this fuel. It provides more efficient sulfur capture, lower NO{sub x} emissions, better solids-handling capability, and can utilize a wetter feedstock, requiring less crushing and sizing. The lower operating temperature of CFBC boilers (820 C) reduces the risk of fouling and agglomeration. Care must be taken to minimize heat loss in the system to accommodate the low heating value of the coal.« less
Combustion Of Poultry-Derived Fuel in a CFBC
NASA Astrophysics Data System (ADS)
Jia, Lufei; Anthony, Edward J.
Poultry farming generates large quantities of waste. Current disposal practice is to spread the poultry wastes onto farmland as fertilizer. However, as the factory farms for poultry grow both in numbers and size, the amount of poultry wastes generated has increased significandy in recent years. In consequence, excessive application of poultry wastes on farmland is resulting in more and more contaminants entering the surface water. One of the options being considered is the use of poultry waste as power plant fuel. Since poultry-derived fuel (PDF) is biomass, its co-firing will have the added advantage of reducing greenhouse gas emissions from power generation. To evaluate the combustion characteristics of co-firing PDF with coal, combustion tests of mixtures of coal and PDF were conducted in CanmetENERGY's pilot-scale CFBC. The goal of the tests was to verify that PDF can be co-fired with coal and, more importantly, that emissions from the combustion process are not adversely affected by the presence of PDF in the fuel feed. The test results were very promising and support the view that co-firing in an existing coal-fired CFBC is an effective method of utilizing this potential fuel, both resolving a potential waste disposal problem and reducing the amount of CO2 released by the boiler.
Japanese RDF-fired power generation system and fundamental research on RDF combustion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Narukawa, Kimihito; Goto, Hidenori; Chen, Y.
1997-12-31
Power generation from refuse derived fuel (RDF) is one of the new technologies for municipal solid waste (MSW) management. This technology is strongly attracting the attention of the Japanese government. The results of a feasibility study of this system in Japan is presented. To develop this highly efficient RDF-fired CFB generating process, combustibility and dechlorination characteristics of RDF were investigated by both the thermo-balance technique and combustion tests with an electric furnace. RDF combustion tests by a bench scale CFBC were carried out and then the following experimental results were obtained: (1) RDF can be combusted almost completely even inmore » small scale CFBC; (2) HCl and N{sub 2}O emissions are quite low at any conditions; and (3) NO{sub x} emissions are a little higher in single stage combustion, however they are reduced at 50% air bias ratio. Some of the results can be explained by a RDF combustion model.« less
Review of Facility Technology Options and their Development Status
1989-06-01
added to these commercial technologies, such as flue gas desulfurization and low-NO x burners. " New coal-fired power technologies, such as AFBC, CFBC...Issues When compared to conventional technologies with pollution control equipment (such as pulverized coal/ flue gas desulfurization ), AFBC/CFBC systems...performance trade- offs exist. Since less energy is available in the flue gas as a result of heating water, less refrigerant vapor will be
Regenerable cement sorbent for recycle fluidized-bed combustion systems. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoo, H.J.; Steinberg, M.
1985-04-01
Agglomerated cement sorbent pellets (ACS) were investigated as a regenerable sorbent for the purpose of removing SO/sub 2/ in a circulating fluidized-bed combustion (CFBC) system. The systems concept is to use an intermediate size sorbent pellet so that fine flyash can be separated from the sorbent at the top end of the CFBC and the coarse gangue can be separated from the sorbent remaining in the bottom end. In this study, basic experimental data were obtained on the sulfur capture capacity and regenerability of the ACS pellets as a function of the concentration of flyash mixed with the pellets andmore » as a function of temperature. Thermogravimetric Analysis (TGA) was used for this purpose. A 40 mm bench-scale fluidized-bed unit operated with a simulated combustion gas mixture was used to determine the attrition resistance of the pellets. The results indicate that 30-100 mesh ACS pellets at 958/sup 0/C (1756/sup 0/F) maintain a 55-60% sulfation capacity mixed with coal flyash concentration up to 75% by weight. The sorbent pellets were 100% regenerable and did not lose reactivity in repeated cyclical sulfation and regeneration tests. At higher temperatures up to 1158/sup 0/C (2116/sup 0/F) reactivity towards SO/sub 2/ declines due to sintering of the flyash on the surface of the ACS pellets. Tests showed good attrition resistance with only 1% loss per cycle in cyclical operation. These initial basic results indicate that ACS pellets are potentially useful as a recoverable and regenerable high capacity SO/sub 2/ sorbent in a circulating fluidized-bed combustion system. 5 refs., 7 figs., 8 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu Hui; Li Qin; Shen Lifeng
2010-01-15
In this contribution, low-reactive circulating fluidized bed combustion (CFBC) fly ashes (CFAs) have firstly been utilized as a source material for geopolymer synthesis. An alkali fusion process was employed to promote the dissolution of Si and Al species from the CFAs, and thus to enhance the reactivity of the ashes. A high-reactive metakaolin (MK) was also used to consume the excess alkali needed for the fusion. Reactivities of the CFAs and MK were examined by a series of dissolution tests in sodium hydroxide solutions. Geopolymer samples were prepared by alkali activation of the source materials using a sodium silicate solutionmore » as the activator. The synthesized products were characterized by mechanical testing, scanning electron microscopy (SEM), X-ray diffractography (XRD), as well as Fourier transform infrared spectroscopy (FTIR). The results of this study indicate that, via enhancing the reactivity by alkali fusion and balancing the Na/Al ratio by additional aluminosilicate source, low-reactive CFAs could also be recycled as an alternative source material for geopolymer production.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feihu Li; Jianping Zhai; Xiaoru Fu
2006-08-15
The chemistry, mineralogy, morphology, and particle size distribution were investigated in fly ashes from the burning of Datong (ShanXi, China) bituminous coal and the cofiring of Mideast high-sulfur petroleum coke (PC) with 30:70 (cal %) and 50:50 (cal %) blends of Datong bituminous coal in two commercial CFBC boilers. With the exception of CaO, the amounts of major oxides in the fly ashes from cofiring PC and coal were close to those of the common coal fly ashes. The PC-coal fly ashes were enriched in Ni, V, and Mo, implying these trace elements were mainly derived from PC. Ni andmore » V, along with several other elements, such as Cr, Cu, Se, Pb, U, Th, and possibly As and Cd, increased in content with a decrease in temperature of the electrostatic precipitator (ESP). The results of chemistry, mineralogy, and morphology studies suggested that the desulfurization rate of the CFBC boilers at current conditions was low, and the PC tends to coarsen the fly ash particles and increase the loss on ignition (LOI) values, making these fly ashes unsuitable for use as a cement additive or a mineral admixture in concrete. Further studies on the combustion status of the CFBC boilers are needed if we want to be able to increase the desulfurization rate and produce high-quality fly ashes for broader and full utilization. 22 refs., 4 figs., 4 tabs.« less
NASA Astrophysics Data System (ADS)
Yong, Yumei; Lu, Qinggang
2003-05-01
The combustion performance of the boiler largely depends on the coal type. Lots of experimental research shows that different fuels have different combustion characteristics. It is obvious that fuel will change the whole operating performance of Circulating Fluidized Bed Combustion (CFBC). We know even in a pilot-scale running boiler, the measurement of some parameters is difficult and costly. Therefore, we developed the way of simulation to evaluate the combustion performance of Chinese coals in CFB. The simulation results show that, different coals will result in different coal particle diameter and comminution depending on their mineral component and the change will affect the distribution of ash in CFBC system. In a word, the computational results are in accordance with experimental results qualitatively but there are some differences quantitatively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei-Ping Pan; Andy Wu; John T. Riley
This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period October 1, 2004 through December 31, 2004. The following tasks have been completed. First, the renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have proceeded well. Second, the detailed design of supporting and hanging structures for the CFBC was completed. Third, the laboratory-scale simulated fluidized-bed facility was modified after completing a series of pretests. The two problems identified during the pretest were solved.more » Fourth, the carbonization of chicken waste and coal was investigated in a tube furnace and a Thermogravimetric Analyzer (TGA). The experimental results from this study are presented in this report. Finally, the proposed work for the next quarter has been outlined in this report.« less
Radiative heat transfer in strongly forward scattering media of circulating fluidized bed combustors
NASA Astrophysics Data System (ADS)
Ates, Cihan; Ozen, Guzide; Selçuk, Nevin; Kulah, Gorkem
2016-10-01
Investigation of the effect of particle scattering on radiative incident heat fluxes and source terms is carried out in the dilute zone of the lignite-fired 150 kWt Middle East Technical University Circulating Fluidized Bed Combustor (METU CFBC) test rig. The dilute zone is treated as an axisymmetric cylindrical enclosure containing grey/non-grey, absorbing, emitting gas with absorbing, emitting non/isotropically/anisotropically scattering particles surrounded by grey diffuse walls. A two-dimensional axisymmetric radiation model based on Method of Lines (MOL) solution of Discrete Ordinates Method (DOM) coupled with Grey Gas (GG)/Spectral Line-Based Weighted Sum of Grey Gases Model (SLW) and Mie theory/geometric optics approximation (GOA) is extended for incorporation of anisotropic scattering by using normalized Henyey-Greenstein (HG)/transport approximation for the phase function. Input data for the radiation model is obtained from predictions of a comprehensive model previously developed and benchmarked against measurements on the same CFBC burning low calorific value indigenous lignite with high volatile matter/fixed carbon (VM/FC) ratio in its own ash. Predictive accuracy and computational efficiency of nonscattering, isotropic scattering and forward scattering with transport approximation are tested by comparing their predictions with those of forward scattering with HG. GG and GOA based on reflectivity with angular dependency are found to be accurate and CPU efficient. Comparisons reveal that isotropic assumption leads to under-prediction of both incident heat fluxes and source terms for which discrepancy is much larger. On the other hand, predictions obtained by neglecting scattering were found to be in favorable agreement with those of forward scattering at significantly less CPU time. Transport approximation is as accurate and CPU efficient as HG. These findings indicate that negligence of scattering is a more practical choice in solution of the radiative transfer equation (RTE) in conjunction with conservation equations for the system under consideration.
NASA Technical Reports Server (NTRS)
Sajben, Miklos; Freund, Donald D.
1998-01-01
The ability to predict the dynamics of integrated inlet/compressor systems is an important part of designing high-speed propulsion systems. The boundaries of the performance envelope are often defined by undesirable transient phenomena in the inlet (unstart, buzz, etc.) in response to disturbances originated either in the engine or in the atmosphere. Stability margins used to compensate for the inability to accurately predict such processes lead to weight and performance penalties, which translate into a reduction in vehicle range. The prediction of transients in an inlet/compressor system requires either the coupling of two complex, unsteady codes (one for the inlet and one for the engine) or else a reliable characterization of the inlet/compressor interface, by specifying a boundary condition. In the context of engineering development programs, only the second option is viable economically. Computations of unsteady inlet flows invariably rely on simple compressor-face boundary conditions (CFBC's). Currently, customary conditions include choked flow, constant static pressure, constant axial velocity, constant Mach number or constant mass flow per unit area. These conditions are straightforward extensions of practices that are valid for and work well with steady inlet flows. Unfortunately, it is not at all likely that any flow property would stay constant during a complex system transient. At the start of this effort, no experimental observation existed that could be used to formulate of verify any of the CFBC'S. This lack of hard information represented a risk for a development program that has been recognized to be unacceptably large. The goal of the present effort was to generate such data. Disturbances reaching the compressor face in flight may have complex spatial structures and temporal histories. Small amplitude disturbances may be decomposed into acoustic, vorticity and entropy contributions that are uncoupled if the undisturbed flow is uniform. This study is focused on the response of an inlet/compressor system to acoustic disturbances. From the viewpoint of inlet computations, acoustic disturbances are clearly the most important, since they are the only ones capable of moving upstream. Convective and entropy disturbances may also produce upstream-moving acoustic waves, but such processes are outside the scope of the present study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng Guanghong; Li Qin; Zhai Jianping
2007-06-15
Self-cementitious properties of fly ash from circulating fluidized bed combustion boiler co-firing coal and high-sulphur petroleum coke (CPFA) were investigated. CPFA was self-cementitious which was affected by its fineness and chemical compositions, especially the contents of SO{sub 3} and free lime (f-CaO). Higher contents of SO{sub 3} and f-CaO were beneficial to self-cementitious strength; the self-cementitious strength increases with a decrease of its 45 {mu}m sieve residue. The expansive ratio of CPFA hardened paste was high because of generation of ettringite (AFt), which was influenced by its water to binder ratio (W/A), curing style and grinding of the ash. Themore » paste cured in water had the highest expansive ratio, and grinding of CPFA was beneficial to its volume stability. The hydration products of CPFA detected by X-ray diffraction (XRD) and scanning electron microscopy (SEM) were portlandite, gypsum, AFt and hydrated calcium silicate (C-S-H)« less
CO2 mineral sequestration in oil-shale wastes from Estonian power production.
Uibu, Mai; Uus, Mati; Kuusik, Rein
2009-02-01
In the Republic of Estonia, local low-grade carbonaceous fossil fuel--Estonian oil-shale--is used as a primary energy source. Combustion of oil-shale is characterized by a high specific carbon emission factor (CEF). In Estonia, the power sector is the largest CO(2) emitter and is also a source of huge amounts of waste ash. Oil-shale has been burned by pulverized firing (PF) since 1959 and in circulating fluidized-bed combustors (CFBCs) since 2004-2005. Depending on the combustion technology, the ash contains a total of up to 30% free Ca-Mg oxides. In consequence, some amount of emitted CO(2) is bound by alkaline transportation water and by the ash during hydraulic transportation and open-air deposition. The goal of this study was to investigate the possibility of improving the extent of CO(2) capture using additional chemical and technological means, in particular the treatment of aqueous ash suspensions with model flue gases containing 10-15% CO(2). The results indicated that both types of ash (PF and CFBC) could be used as sorbents for CO(2) mineral sequestration. The amount of CO(2) captured averaged 60-65% of the carbonaceous CO(2) and 10-11% of the total CO(2) emissions.
Zou, Lin; Feng, Yan; Li, Yan; Zhang, Ming; Chen, Chan; Cai, Jiayan; Gong, Yu; Wang, Larry; Thurman, Joshua M.; Wu, Xiaobo; Atkinson, John P.; Chao, Wei
2013-01-01
Severe sepsis involves massive activation of the innate immune system and leads to high mortality. Previous studies have demonstrated that various types of Toll-like receptors (TLRs) mediate a systemic inflammatory response and contribute to organ injury and mortality in animal models of severe sepsis. However, the downstream mechanisms responsible for TLR-mediated septic injury are poorly understood. Here, we show that activation of TLR2, TLR3 and TLR4 markedly enhanced complement factor B (cfB) synthesis and release by macrophages and cardiac cells. Polymicrobial sepsis, created by cecal ligation and puncture (CLP) in a mouse model, augmented cfB levels in the serum, peritoneal cavity and major organs including the kidney and heart. CLP also led to the alternative pathway (AP) activation, C3 fragment deposition in the kidney and heart, and cfB-dependent C3dg elevation. Bacteria isolated from septic mice activated the serum AP via a factor D-dependent manner. MyD88 deletion attenuated cfB/C3 up-regulation as well as cleavage induced by polymicrobial infection. Importantly, during sepsis, absence of cfB conferred a protective effect with improved survival and cardiac function, and markedly attenuated acute kidney injury. cfB deletion also led to increased neutrophil migratory function during the early phase of sepsis, decreased local and systemic bacterial load, attenuated cytokine production and reduced neutrophil reactive oxygen species production. Together, our data indicate that cfB acts as a downstream effector of TLR signaling and plays a critical role in the pathogenesis of severe bacterial sepsis. PMID:24154627
System Testing of Ground Cooling System Components
NASA Technical Reports Server (NTRS)
Ensey, Tyler Steven
2014-01-01
This internship focused primarily upon software unit testing of Ground Cooling System (GCS) components, one of the three types of tests (unit, integrated, and COTS/regression) utilized in software verification. Unit tests are used to test the software of necessary components before it is implemented into the hardware. A unit test determines that the control data, usage procedures, and operating procedures of a particular component are tested to determine if the program is fit for use. Three different files are used to make and complete an efficient unit test. These files include the following: Model Test file (.mdl), Simulink SystemTest (.test), and autotest (.m). The Model Test file includes the component that is being tested with the appropriate Discrete Physical Interface (DPI) for testing. The Simulink SystemTest is a program used to test all of the requirements of the component. The autotest tests that the component passes Model Advisor and System Testing, and puts the results into proper files. Once unit testing is completed on the GCS components they can then be implemented into the GCS Schematic and the software of the GCS model as a whole can be tested using integrated testing. Unit testing is a critical part of software verification; it allows for the testing of more basic components before a model of higher fidelity is tested, making the process of testing flow in an orderly manner.
Architecture-Based Unit Testing of the Flight Software Product Line
NASA Technical Reports Server (NTRS)
Ganesan, Dharmalingam; Lindvall, Mikael; McComas, David; Bartholomew, Maureen; Slegel, Steve; Medina, Barbara
2010-01-01
This paper presents an analysis of the unit testing approach developed and used by the Core Flight Software (CFS) product line team at the NASA GSFC. The goal of the analysis is to understand, review, and reconunend strategies for improving the existing unit testing infrastructure as well as to capture lessons learned and best practices that can be used by other product line teams for their unit testing. The CFS unit testing framework is designed and implemented as a set of variation points, and thus testing support is built into the product line architecture. The analysis found that the CFS unit testing approach has many practical and good solutions that are worth considering when deciding how to design the testing architecture for a product line, which are documented in this paper along with some suggested innprovennents.
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...
29 CFR 1919.71 - Unit proof test and examination of cranes.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof test and examination of cranes. 1919.71 Section... § 1919.71 Unit proof test and examination of cranes. (a) Unit proof tests of cranes shall be carried out at the following times: (1) In the cases of new cranes, before initial use and every 4 years...
Unit Testing for Command and Control Systems
NASA Technical Reports Server (NTRS)
Alexander, Joshua
2018-01-01
Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.
ACER Physics Unit Tests: Unit Tests, Diagnostic Aids, [and] Teachers Handbook.
ERIC Educational Resources Information Center
Australian Council for Educational Research, Hawthorn.
The Physics Unit Tests are designed to assist in the diagnostic evaluation of students' progress in the study of physics during the last two years of secondary schooling. They consist of a collection of 21 separate tests, each related to a different topic, and 21 diagnostic aids corresponding to the tests. The topics covered are: physical…
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2014-10-01 2014-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2013-10-01 2013-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
42 CFR 84.310 - Post-approval testing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Respirators § 84.310 Post-approval testing. (a) NIOSH will periodically test the capacity and performance of units of approved CCERs. (b) NIOSH may test units that are new and/or units that have been deployed in... 42 Public Health 1 2012-10-01 2012-10-01 false Post-approval testing. 84.310 Section 84.310 Public...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number ismore » used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.« less
NASA Technical Reports Server (NTRS)
Platt, R.
1999-01-01
This is the Performance Verification Report, Initial Comprehensive Performance Test Report, P/N 1331200-2-IT, S/N 105/A2, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). The specification establishes the requirements for the Comprehensive Performance Test (CPT) and Limited Performance Test (LPT) of the Advanced Microwave Sounding, Unit-A2 (AMSU-A2), referred to herein as the unit. The unit is defined on Drawing 1331200. 1.2 Test procedure sequence. The sequence in which the several phases of this test procedure shall take place is shown in Figure 1, but the sequence can be in any order.
ARI Environmental, Inc. (ARI) was retained by Houston Refining LP (HRO) to conduct an emission test program at their refinery located in Houston, Texas. The testing was conducted on on the 736 Delayed Coking Unit (DCU) in response to EPA's ICR.
Test Report of Special Form Qualification Testing for the ORNL U ZipCan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, Oscar A.
This test report describes the special form testing activities performed on the two ZiPCans. One prototype test unit was subjected to the tests stipulated by 10 CFR 71.75 (d)(1)(i), ISO 2919:1999(E) Class 4 impact test, along with the leak rate test specified in 49 CFR 173.469(a)(4)(i). The other test unit was subjected to a leak rate test as specified in 173.469(a)(4)(i) and a heat test as specified in 49 CFR 173.469 (b)(4). Each test unit was leak tested before and after these respective tests. The leak rate tests performed were helium back-pressure tests and bubble tests, as specified in ANSImore » N14.5-2014.The measured leak rates were converted to standard condition leak rates as specified in ASTM E 493. The determined standardized leak rates from the test and calculation for both test units met the requirements for special form certification.« less
NASA Technical Reports Server (NTRS)
Zachary, A. T.; Csomor, A.; Tignac, L. L.
1973-01-01
Small, high-performance LO2 and LH2 turbopump assembly configurations were selected, detail designs were prepared and two of each unit were fabricated with each unit consisting of pump, turbine gas generator, and appropriate controls. Following fabrication, development testing was conducted on each type to demonstrate performance, durability, transient characteristics, and heat transfer under simulated altitude conditions. Following successful completion of development effort, the two LO2 turbopump units and one LH2 turbopump unit were acceptance tested as specified. Inspection of the units following development testing revealed no deleterious effects of testing. The test results of LO2 turbopump assembly testing correlated well with predicted performance while the LH2 turbopump test results, though generally consistent with predicted values, did show lower than anticipated developed head at the design point and in the high flow range of operation.
Cost implications of implementation of pathogen-inactivated platelets
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-01-01
BACKGROUND Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. STUDY DESIGN AND METHODS Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing 1) special requests and 2) test results, 3) quality control and proficiency testing, 4) equipment acquisition and maintenance, 5) replacement of units lost to positive tests, 6) seasonal or geographic testing, and 7) health department interactions. RESULTS All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. CONCLUSIONS While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. PMID:25989465
Cost implications of implementation of pathogen-inactivated platelets.
McCullough, Jeffrey; Goldfinger, Dennis; Gorlin, Jed; Riley, William J; Sandhu, Harpreet; Stowell, Christopher; Ward, Dawn; Clay, Mary; Pulkrabek, Shelley; Chrebtow, Vera; Stassinopoulos, Adonis
2015-10-01
Pathogen inactivation (PI) is a new approach to blood safety that may introduce additional costs. This study identifies costs that could be eliminated, thereby mitigating the financial impact. Cost information was obtained from five institutions on tests and procedures (e.g., irradiation) currently performed, that could be eliminated. The impact of increased platelet (PLT) availability due to fewer testing losses, earlier entry into inventory, and fewer outdates with a 7-day shelf life were also estimated. Additional estimates include costs associated with managing (1) special requests and (2) test results, (3) quality control and proficiency testing, (4) equipment acquisition and maintenance, (5) replacement of units lost to positive tests, (6) seasonal or geographic testing, and (7) health department interactions. All costs are mean values per apheresis PLT unit in USD ($/unit). The estimated test costs that could be eliminated are $71.76/unit and a decrease in transfusion reactions corresponds to $2.70/unit. Avoiding new tests (e.g., Babesia and dengue) amounts to $41.80/unit. Elimination of irradiation saves $8.50/unit, while decreased outdating with 7-day storage can be amortized to $16.89/unit. Total potential costs saved with PI is $141.65/unit. Costs are influenced by a variety of factors specific to institutions such as testing practices and the location in which such costs are incurred and careful analysis should be performed. Additional benefits, not quantified, include retention of some currently deferred donors and scheduling flexibility due to 7-day storage. While PI implementation will result in additional costs, there are also potential offsetting cost reductions, especially after 7-day storage licensing. © 2015 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.
NASA Technical Reports Server (NTRS)
Platt, R.
1998-01-01
This is the Performance Verification Report. the process specification establishes the requirements for the comprehensive performance test (CPT) and limited performance test (LPT) of the earth observing system advanced microwave sounding unit-A2 (EOS/AMSU-A2), referred to as the unit. The unit is defined on drawing 1356006.
Improvement for enhancing effectiveness of universal power system (UPS) continuous testing process
NASA Astrophysics Data System (ADS)
Sriratana, Lerdlekha
2018-01-01
This experiment aims to enhance the effectiveness of the Universal Power System (UPS) continuous testing process of the Electrical and Electronic Institute by applying work scheduling and time study methods. Initially, the standard time of testing process has not been considered that results of unaccurate testing target and also time wasting has been observed. As monitoring and reducing waste time for improving the efficiency of testing process, Yamazumi chart and job scheduling theory (North West Corner Rule) were applied to develop new work process. After the improvements, the overall efficiency of the process possibly increased from 52.8% to 65.6% or 12.7%. Moreover, the waste time could reduce from 828.3 minutes to 653.6 minutes or 21%, while testing units per batch could increase from 3 to 4 units. Therefore, the number of testing units would increase from 12 units up to 20 units per month that also contribute to increase of net income of UPS testing process by 72%.
Hunter, Oluwatobi O; George, Elisabeth L; Ren, Dianxu; Morgan, Douglas; Rosenzweig, Margaret; Klinefelter Tuite, Patricia
2017-06-01
To increase adherence with intensive care unit mobility by developing and implementing a mobility training program that addresses nursing barriers to early mobilisation. An intensive care unit mobility training program was developed, implemented and evaluated with a pre-test, immediate post-test and eight-week post-test. Patient mobility was tracked before and after training. A ten bed cardiac intensive care unit. The training program's efficacy was measured by comparing pre-test, immediate post-test and 8-week post-test scores. Patient mobilisation rates before and after training were compared. Protocol compliance was measured in the post training group. Nursing knowledge increased from pre-test to immediate post-test (p<0.0001) and pre-test to 8-week post-test (p<0.0001). Mean test scores decreased by seven points from immediate post-test (80±12) to 8-week post-test (73±14). Fear significantly decreased from pre-test to immediate post-test (p=0.03), but not from pre-test to 8-week post-test (p=0.06) or immediate post-test to 8-week post-test (p=0.46). Post training patient mobility rates increased although not significantly (p=0.07). Post training protocol compliance was 78%. The project successfully increased adherence with intensive care unit mobility and indicates that a training program could improve adoption of early mobility. Copyright © 2016 Elsevier Ltd. All rights reserved.
2010-10-27
John C. Stennis Space Center employees complete installation of a chemical steam generator (CSG) unit at the site's E-2 Test Stand. On Oct. 24, 2010. The unit will undergo verification and validation testing on the E-2 stand before it is moved to the A-3 Test Stand under construction at Stennis. Each CSG unit includes three modules. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Development of action levels for MED/MPD skin-testing units in ultraviolet phototherapy
NASA Astrophysics Data System (ADS)
O'Connor, Una M.; O'Hare, Neil J.
2003-03-01
Ultraviolet (UV) Phototherapy is commonly used for treatment of skin diseases such as psoriasis and eczema. Treatment is carried out using UV phototherapy units, exposing all or part of the body for a certain exposure time. Prior to exposure in treatment units, an unaffected area of skin may be tested using UV skin-testing units in order to determine a suitable treatment regime. The exposure time at which barely perceptible erythema has developed is known as the Minimal Erythemal Dose (MED) for UVB therapy and Minimal Phototoxic Dose (MPD) for UVA therapy. This is used to determine the starting dose in the treatment regime. The presence of 'hotspots' and 'coldspots' in UV skin-testing units can result in inaccurate determination of MED/MPD. This could give rise to severe burns during treatment, or in a sub-optimal dose regime being used. Quality assurance protocols for UV phototherapy equipment have recently been developed and these protocols have highlighted the need for action levels for skin-testing units. An action level is a reference value, which is used to determine whether the difference in irradiance output level across a UV unit is acceptable. Current methodologies for skin-testing in Ireland have been characterised and errors introduced during testing have been estimated. Action levels have been developed based on analysis of errors and requirements of skin-testing.
Swanson, William H.; Horner, Douglas G.; Dul, Mitchell W.; Malinovsky, Victor E.
2014-01-01
Purpose To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Methods Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Results Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively (F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively (P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower (P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Conclusions Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. Translational Relevance The guidelines should allow developers to choose from a wide range of stimuli. PMID:25371855
Swanson, William H; Horner, Douglas G; Dul, Mitchell W; Malinovsky, Victor E
2014-09-01
To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ceiling (maximum sensitivity) and floor (minimum sensitivity). Bland-Altman analysis was used to derive 95% limits of agreement on test and retest, and bootstrap analysis was used to test the hypotheses about peak variability. Limits of agreement for the three custom stimuli were similar in width (0.72 to 0.79 log units) and peak variability (0.22 to 0.29 log units) for a stimulus range of 1.7 log units. The width of the limits of agreement for size III decreased from 1.78 to 1.37 to 0.99 log units for stimulus ranges of 3.9, 2.7, and 1.7 log units, respectively ( F = 3.23, P < 0.001); peak variability was 0.99, 0.54, and 0.34 log units, respectively ( P < 0.01). For a stimulus range of 1.3 log units, limits of agreement were narrowest with Gabor and widest with size III stimuli, and peak variability was lower ( P < 0.01) with Gabor (0.18 log units) and frequency-doubling perimetry (0.24 log units) than with size III stimuli (0.38 log units). Test-retest variability in glaucomatous visual field defects was substantially reduced by engineering the stimuli. The guidelines should allow developers to choose from a wide range of stimuli.
Test report: Electron-proton spectrometer qualification test unit, qualification test
NASA Technical Reports Server (NTRS)
Vincent, D. L.
1972-01-01
Qualification tests of the electron-proton spectrometer test unit are presented. The tests conducted were: (1) functional, (2) thermal/vacuum, (3) electromagnetic interference, (4) acoustic, (5) shock, (6) vibration, and (7) humidity. Results of each type of test are presented in the form of data sheets.
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements for importers who import gasoline into the United States by truck. 80.1349 Section 80.1349... FUELS AND FUEL ADDITIVES Gasoline Benzene Sampling, Testing and Retention Requirements § 80.1349 Alternative sampling and testing requirements for importers who import gasoline into the United States by...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...
Principles of Technology. Units 1-10 Pilot Test Findings.
ERIC Educational Resources Information Center
Center for Occupational Research and Development, Inc., Waco, TX.
This document provides the findings of pilot tests of 10 units for an applied science course for high school vocational students. Each of the reports on the pilot tests of the Principles of Technology units contains information on procedures, methodology limitations, sample, the pretest/posttest instrument and results, student attitude results,…
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto...
10 CFR 431.135 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Automatic Commercial Ice Makers Test Procedures § 431.135 Units to be tested. For each basic model of automatic commercial ice maker selected for testing, a sample of sufficient size shall be selected...
NASA Astrophysics Data System (ADS)
Mosthaf, Klaus; Brauns, Bentje; Fjordbøge, Annika S.; Rohde, Magnus M.; Kerrn-Jespersen, Henriette; Bjerg, Poul L.; Binning, Philip J.; Broholm, Mette M.
2018-06-01
Limestone aquifers are of great interest as a drinking water resource in many countries. They often have a complex crushed and fractured geology, which makes the analysis and description of flow and transport processes in such aquifers a challenging task. In this study, the solute transport behavior including fracture-matrix interaction in hydrogeological units of a limestone aquifer in eastern Denmark was characterized by designing, conducting and interpreting six depth-specific tracer tests involving natural- and forced-gradient conditions with multiple tracers representing different diffusion properties. To determine flow parameters, the tracer tests were complemented by a comprehensive set of depth-specific borehole and hydraulic tests. Based on the tests, a new and stronger conceptual understanding was developed for the different aquifer units. The investigated limestone aquifer is composed of a glacially crushed unit and two fractured units, with calcarenitic and bryozoan limestone of similar hydraulic properties. Hydraulic tests revealed that the crushed unit has a lower hydraulic conductivity than the fractured limestone units, likely due to the crushed conditions with small limestone clusters and small-aperture fractures potentially filled with fine material. In the fractured limestone units, a distinct preferential flow and primary transport along major horizontal fractures was inferred from the tracer tests under forced-gradient conditions. The dominant horizontal fractures were identified on impeller flow logs and appear connected between wells, having an extent of up to several hundred meters. Connectivity between the aquifer units was investigated with a long-term pumping test and tracer tests, revealing restricted vertical flow and transport. A very pronounced hydraulic conductivity contrast between major fractures and matrix could also be inferred from the borehole and hydraulic tests, which is consistent with the findings from the tracer tests. The difference in the matrix diffusion behavior of the simultaneously injected tracers and a long tailing in the breakthrough curves revealed that matrix diffusion has a strong influence on the solute transport in the fractured limestone.
HEMP (high-altitude electromagnetic pulse) test and analysis of selected recloser-control units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, T.K.; Sands, S.H.; Tesche, F.M.
A simulated HEMP test was performed on power line recloser-control units in the ARES facility during the month of October 1988. Two types of recloser-control units were tested: an electronic control unit presently in wide use in electric power distribution systems and a new microprocessor based unit presently being introduced to electric utilities. It was found that the ARES fields did not cause reproducible disruptive failure of the equipment. Minor upsets, which were considered to be non-disruptive to the recloser operation, were observed. The test results were compared to the results of an analysis from a previous study and itmore » is concluded that the probability of disruptive failure of field operating recloser-control units subjected to a nominal unclassified HEMP environment is small. 3 refs., 30 figs., 1 tab.« less
First results from quality assurance testing of MaPMTs for the LHCb RICH upgrade
NASA Astrophysics Data System (ADS)
Gambetta, S.; LHCb RICH Collaboration
2017-12-01
In 2019 the LHCb RICH detector will be upgraded to increase the read out rate from 1 MHz to 40 MHz. As a consequence, the current Hybrid Photon Detectors will have to be replaced. Multi-anode Photomultiplier Tubes (MaPMTs) from Hamamatsu with 64-channels will be used: the 1-in. R13742 and the 2-in. R13743 MaPMTs (custom modifications of the MaPMTs R11625 and R12699). Quality assurance testing of these MaPMTs using custom-developed readout electronics has started. We present the design and realisation of the test facilities to ensure consistency in testing and validation. A total of 3100 units of the R13742 and 450 units of the R13743 will be tested requiring high efficiency and reliability from the test stations. We report on the test programme and protocols, characterising the units and assuring compliance with specifications. First results of testing and detector characterisation will be presented, based on the pre-series production, comprising 54 units of R13742 and 20 units of R13743.
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Flight test results of the strapdown inertial reference unit (SIRU) navigation system are presented. The fault-tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance.
Lucey, C
2006-11-01
This article briefly recounts the 21st July 2005, Blood Products Advisory Committee (BPAC) meeting concerning recommendations for management of donors and units testing positive for hepatitis B virus (HBV) DNA. The author attended the meeting. The United States Food and Drug Administration (FDA) web site was used for meeting materials, and handouts were collected at the meeting to provide narrative information. Two European experts assisted with HBV subject matter. The proceedings of the advisory committee, the issue briefing materials, and testing algorithms are presented. BPAC voted concurrence with the FDA algorithm for Management of Donors and Units Testing Positive for Hepatitis B Virus DNA.
Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina
2010-01-01
The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. An engineering unit, the ASRG engineering unit (EU), was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently under extended operation test at the NASA Glenn Research Center (GRC) to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for the ASRG EU. This paper summarizes details of the test facility design, including the mechanical mounting, heat-rejection system, argon system, control systems, and maintenance. The effort proceeded from requirements definition through design, analysis, build, and test. Initial testing and facility performance results are discussed.
Charge-Control Unit for Testing Lithium-Ion Cells
NASA Technical Reports Server (NTRS)
Reid, Concha M.; Mazo, Michelle A.; Button, Robert M.
2008-01-01
A charge-control unit was developed as part of a program to validate Li-ion cells packaged together in batteries for aerospace use. The lithium-ion cell charge-control unit will be useful to anyone who performs testing of battery cells for aerospace and non-aerospace uses and to anyone who manufacturers battery test equipment. This technology reduces the quantity of costly power supplies and independent channels that are needed for test programs in which multiple cells are tested. Battery test equipment manufacturers can integrate the technology into their battery test equipment as a method to manage charging of multiple cells in series. The unit manages a complex scheme that is required for charging Li-ion cells electrically connected in series. The unit makes it possible to evaluate cells together as a pack using a single primary test channel, while also making it possible to charge each cell individually. Hence, inherent cell-to-cell variations in a series string of cells can be addressed, and yet the cost of testing is reduced substantially below the cost of testing each cell as a separate entity. The unit consists of electronic circuits and thermal-management devices housed in a common package. It also includes isolated annunciators to signal when the cells are being actively bypassed. These annunciators can be used by external charge managers or can be connected in series to signal that all cells have reached maximum charge. The charge-control circuitry for each cell amounts to regulator circuitry and is powered by that cell, eliminating the need for an external power source or controller. A 110-VAC source of electricity is required to power the thermal-management portion of the unit. A small direct-current source can be used to supply power for an annunciator signal, if desired.
Flight test results of the strapdown hexad inertial reference unit (SIRU). Volume 2: Test report
NASA Technical Reports Server (NTRS)
Hruby, R. J.; Bjorkman, W. S.
1977-01-01
Results of flight tests of the Strapdown Inertial Reference Unit (SIRU) navigation system are presented. The fault tolerant SIRU navigation system features a redundant inertial sensor unit and dual computers. System software provides for detection and isolation of inertial sensor failures and continued operation in the event of failures. Flight test results include assessments of the system's navigational performance and fault tolerance. Performance shortcomings are analyzed.
Unit Testing for the Application Control Language (ACL) Software
NASA Technical Reports Server (NTRS)
Heinich, Christina Marie
2014-01-01
In the software development process, code needs to be tested before it can be packaged for release in order to make sure the program actually does what it says is supposed to happen as well as to check how the program deals with errors and edge cases (such as negative or very large numbers). One of the major parts of the testing process is unit testing, where you test specific units of the code to make sure each individual part of the code works. This project is about unit testing many different components of the ACL software and fixing any errors encountered. To do this, mocks of other objects need to be created and every line of code needs to be exercised to make sure every case is accounted for. Mocks are important to make because it gives direct control of the environment the unit lives in instead of attempting to work with the entire program. This makes it easier to achieve the second goal of exercising every line of code.
NASA Astrophysics Data System (ADS)
Latimer, T. W.; Rinehart, G. H.
1992-05-01
This report covers progress on the Milliwatt Generator Project from April 1986 through March 1988. Activities included fuel processing and characterization, production of heat sources, fabrication of pressure-burst test units, compatibility studies, impact testing, and examination of surveillance units. The major task of the Los Alamos Milliwatt Generator Project is to fabricate MC2893A heat sources (4.0 W) for MC2730A radioisotope thermoelectric generators (RTG's) and MC3599 heat sources (4.5 W) for MC3500 RTG's. The MWG Project interfaces with the following contractors: Sandia National Laboratories, Albuquerque (designer); E.I. du Pont de Nemours and Co. (Inc.), Savannah River Plant (fuel); Monsanto Research Corporation, Mound Facility (metal hardware); and General Electric Company, Neutron Devices Department (RTG's). In addition to MWG fabrication activities, Los Alamos is involved in (1) fabrication of pressure-burst test units, (2) compatibility testing and evaluation, (3) examination of surveillance units, and (4) impact testing and subsequent examination of compatibility and surveillance units.
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Construction test. 7.67 Section 7.67 Mineral... MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Multiple-Shot Blasting Units § 7.67 Construction test. The constuction test is to be performed on the blasting unit subsequent to the output energy test of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Newcomer, Darrell R.
2007-09-30
Slug-test results obtained from single and multiple, stress-level slug tests conducted during drilling and borehole advancement provide detailed hydraulic conductivity information at two Hanford Site Operable Unit (OU) ZP-1 test well locations. The individual test/depth intervals were generally sited to provide hydraulic-property information within the upper ~10 m of the unconfined aquifer (i.e., Ringold Formation, Unit 5). These characterization results complement previous and ongoing drill-and-test characterization programs at surrounding 200-West and -East Area locations (see Figure S.1).
Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report
NASA Technical Reports Server (NTRS)
Roberts, Eileen; Villani, James A.; Ritter, Paul
1997-01-01
This document is the Aviation System Analysis Capability (ASAC) Quick Response System (QRS) Test Report. The purpose of this document is to present the results of the QRS unit and system tests in support of the ASAC QRS development effort. This document contains an overview of the project background and scope, defines the QRS system and presents the additions made to the QRS this year, explains the assumptions, constraints, and approach used to conduct QRS Unit and System Testing, and presents the schedule used to perform QRS Testing. The document also presents an overview of the Logistics Management Institute (LMI) Test Facility and testing environment and summarizes the QRS Unit and System Test effort and results.
10 CFR 431.295 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Refrigerated Bottled or Canned Beverage Vending Machines Test Procedures § 431.295 Units to be tested. For each basic model of refrigerated bottled or canned beverage vending machine selected for...
Status of Hollow Cathode Heater Development for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Heater tests included testing of the heater unit alone and plasma contactor and ion thruster testing. To date, eight heaters have been or are being processed through heater unit testing, two through plasma contactor testing and three through ion thruster testing, all using direct current power supplies. Comparisons of data from heater unit performance tests before cyclic testing, plasma contactor tests, and ion thruster tests at the ignition input current level show the average deviation of input power and tube temperature near the cathode tip to be +/-0.9 W and +/- 21 C, respectively. Heater unit testing included cyclic testing to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Four additional heaters successfully completed 6300, 6300, 700, and 700 cycles. Heater unit testing is currently ongoing for three heaters which have to date accumulated greater than 7250, greater than 5500, and greater than 5500 cycles, respectively.
Test report: Shock test of the electron/proton spectrometer structural test unit
NASA Technical Reports Server (NTRS)
Vincent, D. L.
1972-01-01
A shock test of the electron-proton spectrometer structural test unit was conducted. The purpose of the shock test was to verify the structural integrity of the electron-spectrometer design and to obtain data on the shock response of the electronics and electronic housing. The test equipment is described and typical shock response data are provided.
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
14 CFR 120.123 - Drug testing outside the territory of the United States.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Drug testing outside the territory of the... OPERATIONS DRUG AND ALCOHOL TESTING PROGRAM Drug Testing Program Requirements § 120.123 Drug testing outside the territory of the United States. (a) No part of the testing process (including specimen collection...
Tensile testing of thin-film microstructures
NASA Astrophysics Data System (ADS)
Greek, Staffan; Johansson, Stefan A. I.
1997-09-01
The mechanical properties of thin film microstructures depend on size and shape and on the film manufacturing process. Hence, the test structures that are used to measure mechanical properties should have dimensions of the same order of magnitude as an application structure. The microstructures are easily monitored in a scanning electron microscope (SEM), but to be handled and tested in situ a micromanipulator was developed. The parts of the micromanipulator essential to the tests are two independently moveable tables driven by electric motors. The test structures and a testing unit are mounted on the tables. A testing unit was designed to measure force and displacement with high resolution. The testing unit consists of an arm actuated by a piezoelectric element and equipped with a probe. An optical encoder measures the movement of the arm, while strain gauges measure the force in the arm. Test structures consist typically of a released beam fixed at one end with a ring at the other. The micromanipulator is used to position the probe of the testing unit in the ring. The testing unit then executed a tensile test of the beam. Test structures of polysilicon films produced under various process conditions were used to verify the possibility of measuring Young's modulus with an accuracy of +/- 5 percent, as well as fracture strength.Young's modulus is calculated using the difference in elongation for different beam lengths. The fracture strength of the beams was evaluated with Weibull statistics.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-26
... Plant, Unit 4; Inspections, Tests, Analyses, and Acceptance Criteria AGENCY: Nuclear Regulatory Commission. ACTION: Determination of inspections, tests, analyses, and acceptance criteria completion. SUMMARY: The U.S. Nuclear Regulatory Commission (NRC) staff has determined that the inspections, tests...
NASA Technical Reports Server (NTRS)
Platt, R.
1999-01-01
This is the Performance Verification Report, Final Comprehensive Performance Test (CPT) Report, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A). This specification establishes the requirements for the CPT and Limited Performance Test (LPT) of the AMSU-1A, referred to here in as the unit. The sequence in which the several phases of this test procedure shall take place is shown.
Code of Federal Regulations, 2011 CFR
2011-04-01
... activity outside the United States; 45 hour and 7-day work test. 404.417 Section 404.417 Employees... activity outside the United States; 45 hour and 7-day work test. (a) Deductions because of individual's... on. Effective May 1983, a 45-hour work test applies before a benefit deduction is made for the non...
Code of Federal Regulations, 2010 CFR
2010-04-01
... activity outside the United States; 45 hour and 7-day work test. 404.417 Section 404.417 Employees... activity outside the United States; 45 hour and 7-day work test. (a) Deductions because of individual's... on. Effective May 1983, a 45-hour work test applies before a benefit deduction is made for the non...
Criterion Referenced Tests to Accompany "Artes Latinae," Level 1, Book 1. Tentative Edition.
ERIC Educational Resources Information Center
Masciantonio, Rudolph
These tests are designed to measure the achievement of each pupil at the approximate midpoint of each unit in "Artes Latinae," Level 1, Book 1. They were produced in response to the need expressed by many teachers to provide a means of more frequent evaluation of pupil progress. Tests for 13 units are provided. They supplement the unit tests…
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for Performance Tests...
Testing for unit root bilinearity in the Brazilian stock market
NASA Astrophysics Data System (ADS)
Tabak, Benjamin M.
2007-11-01
In this paper a simple test for detecting bilinearity in a stochastic unit root process is used to test for the presence of nonlinear unit roots in Brazilian equity shares. The empirical evidence for a set of 53 individual stocks, after adjusting for GARCH effects, suggests that for more than 66%, the hypothesis of unit root bilinearity is accepted. Therefore, the dynamics of Brazilian share prices is in conformity with this type of nonlinearity. These nonlinearities in spot prices may emerge due to the sophistication of the derivatives market.
Pre-production Test Report for Transformer Abort Sensing and Control Unit.
The purpose of the report is to describe the test equipment and procedure required for the pre-production testing of a transformer, pressure switch excitation, abort sensing and control unit. (Author)
Needleman, Jack; Pearson, Marjorie L; Upenieks, Valda V; Yee, Tracy; Wolstein, Joelle; Parkerton, Melissa
2016-02-01
Process improvement stresses the importance of engaging frontline staff in implementing new processes and methods. Yet questions remain on how to incorporate these activities into the workday of hospital staff or how to create and maintain its commitment. In a 15-month American Organization of Nurse Executives collaborative involving frontline medical/surgical staff from 67 hospitals, Transforming Care at the Bedside (TCAB) was evaluated to assess whether participating units successfully implemented recommended change processes, engaged staff, implemented innovations, and generated support from hospital leadership and staff. In a mixed-methods analysis, multiple data sources, including leader surveys, unit staff surveys, administrative data, time study data, and collaborative documents were used. All units reported establishing unit-based teams, of which >90% succeeded in conducting tests of change, with unit staff selecting topics and making decisions on adoption. Fifty-five percent of unit staff reported participating in unit meetings, and 64%, in tests of change. Unit managers reported substantial increase in staff support for the initiative. An average 36 tests of change were conducted per unit, with 46% of tested innovations sustained, and 20% spread to other units. Some 95% of managers and 97% of chief nursing officers believed that the program had made unit staff more likely to initiate change. Among staff, 83% would encourage adoption of the initiative. Given the strong positive assessment of TCAB, evidence of substantial engagement of staff in the work, and the high volume of innovations tested, implemented, and sustained, TCAB appears to be a productive model for organizing and implementing a program of frontline-led improvement.
Environmental Test Screening Procedure
NASA Technical Reports Server (NTRS)
Zeidler, Janet
2000-01-01
This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.
Chemical analysis kit for the presence of explosives
Eckels, Joel Del [Livermore, CA; Nunes,; Peter, J [Danville, CA; Alcaraz, Armando [Livermore, CA; Whipple, Richard E [Livermore, CA
2011-05-10
A tester for testing for explosives associated with a test location comprising a first explosives detecting reagent; a first reagent holder, the first reagent holder containing the first explosives detecting reagent; a second explosives detecting reagent; a second reagent holder, the second reagent holder containing the second explosives detecting reagent; a sample collection unit for exposure to the test location, exposure to the first explosives detecting reagent, and exposure to the second explosives detecting reagent; and a body unit containing a heater for heating the sample collection unit for testing the test location for the explosives.
Practical Business: Instructor/Student Guide.
ERIC Educational Resources Information Center
Napier, Deedee Stocker
Ten units on practical business are presented in this instructor and student guide. Each instructional unit contains objectives, suggested activities, information sheets, assignment sheets, transparency master, a test, and test answers. Unit topics are (1) before you buy (comparative shopping and wise purchasing techniques); (2) when things go…
Identification of the Parameters of Menétrey -Willam Failure Surface of Calcium Silicate Units
NASA Astrophysics Data System (ADS)
Radosław, Jasiński
2017-10-01
The identification of parameters of Menétrey-Willamsurface made of concrete, masonry or autoclaved aerated concrete is not complicated. It is much more difficult to identify failure parameters of masonry units with cavities. This paper describes the concept of identifying the parameters of Menétrey-Willam failure surface (M-W-3) with reference to masonry units with vertical cavities. The M-W-3 surface is defined by uniaxial compressive strength fc, uniaxial tensile strength ft and eccentricity of elliptical function e. A test stand was built to identify surface parameters. It was used to test behaviour of masonry units under triaxial stress and conduct tests on whole masonry units in the uniaxial state. Results from tests on tens of silicate masonry units are presented in the Haigh-Westergaard (H-W) space. Statistical analyses were used to identify the shape of surface meridian, and then to determine eccentricity of the elliptical function.
Auxiliary propulsion system flight package
NASA Technical Reports Server (NTRS)
Collett, C. R.
1987-01-01
Hughes Aircraft Company developed qualified and integrated flight, a flight test Ion Auxiliary Propulsion System (IAPS), on an Air Force technology satellite. The IAPS Flight Package consists of two identical Thruster Subsystems and a Diagnostic Subsystem. Each thruster subsystem (TSS) is comprised of an 8-cm ion Thruster-Gimbal-Beam Shield Unit (TGBSU); Power Electronics Unit; Digital Controller and Interface Unit (DCIU); and Propellant Tank, Valve and Feed Unit (PTVFU) plus the requisite cables. The Diagnostic Subsystem (DSS) includes four types of sensors for measuring the effect of the ion thrusters on the spacecraft and the surrounding plasma. Flight qualifications of IAPS, prior to installation on the spacecraft, consisted of performance, vibration and thermal-vacuum testing at the unit level, and thermal-vacuum testing at the subsystem level. Mutual compatibility between IAPS and the host spacecraft was demonstrated during a series of performance and environmental tests after the IAPS Flight Package was installed on the spacecraft. After a spacecraft acoustic test, performance of the ion thrusters was reverified by removing the TGBSUs for a thorough performance test at Hughes Research Laboratories (HRL). The TGBSUs were then reinstalled on the spacecraft. The IAPS Flight Package is ready for flight testing when Shuttle flights are resumed.
Testing the system detection unit for measuring solid minerals bulk density
NASA Astrophysics Data System (ADS)
Voytyuk, I. N.; Kopteva, A. V.
2017-10-01
The paper provides a brief description of the system for measuring flux per volume of solid minerals via example of mineral coal. The paper discloses the operational principle of the detection unit. The paper provides full description of testing methodology, as well as practical implementation of the detection unit testing. This paper describes the removal of two data arrays via the channel of scattered anddirect radiation for the detection units of two generations. This paper describes Matlab software to determine the statistical characteristics of the studied objects. The mean value of pulses per cycles, and pulse counting inaccuracy relatively the mean value were determined for the calculation of the stability account of the detection units.
Whole blood coagulation analyzers.
1997-08-01
Whole blood Coagulation analyzers (WBCAs) are widely used point-of-care (POC) testing devices found primarily in cardiothoracic surgical suites and cardia catheterization laboratories. Most of these devices can perform a number of coagulation tests that provide information about a patient's blood clotting status. Clinicians use the results of the WBCA tests, which are available minutes after applying a blood sample, primarily to monitor the effectiveness of heparin therapy--an anticoagulation therapy used during cardiopulmonary bypass (CPB) surgery, angioplasty, hemodialysis, and other clinical procedures. In this study we evaluated five WBCAs from four suppliers. Our testing focused on the applications for which WBCAs are primarily used: Monitoring moderate to high heparin levels, as would be required, for example, during CPB are angioplasty. For this function, WCBAs are typically used to perform an activated clotting time (ACT) test or, as one supplier refers to its test, a heparin management test (HMT). All models included in this study offered an ACT test or an HMT. Monitoring low heparin levels, as would be required, for example,during hemodialysis. For this function, WBCAs would normally be used to perform either a low-range ACT (LACT) test or a whole blood activated partial thromboplastin time (WBAPTT) test. Most of the evaluated units could perform at least one of these tests; one unit did not offer either test and was therefore not rated for this application. We rated and ranked each evaluated model separately for each of these two applications. In addition, we provided a combined rating and ranking that considers the units' appropriateness for performing both application. We based our conclusions on a unit's performance and humans factor design, as determined by our testing, and on its five-year life-cycle cost, as determined by our net present value (NPV) analysis. While we rated all evaluated units acceptable for each appropriate category, we did identify some significant differences that enabled us to rank the units in order of preference. We have included a Selection, Purchasing, and use guide at the end of this study to help facilities identify the unit that will best meet their needs.
Development of a new photocatalytic oxidation air filter for aircraft cabin.
Ginestet, A; Pugnet, D; Rowley, J; Bull, K; Yeomans, H
2005-10-01
A new photocatalytic oxidation air filter (PCO unit) has been designed for aircraft cabin applications. The PCO unit is designed as a regenerable VOC removal system in order to improve the quality of the recirculated air entering the aircraft cabin. The PCO was designed to be a modular unit, with four UV lamps sandwiched between two interchangeable titanium dioxide coated panels. Performances of the PCO unit has been measured in a single pass mode test rig in order to show the ability of the unit to decrease the amount of VOCs (toluene, ethanol, and acetone) entering it (VOCs are fed separately), and in a multipass mode test rig in order to measure the ability of the unit to clean the air of an experimental room polluted with the same VOCs (fed separately). Triangular cell panels have been chosen instead of the wire mesh panels because they have higher efficiency. The efficiency of the PCO unit depends on the type of VOCs that challenges it, toluene being the most difficult one to oxidise. The efficiency of the PCO unit decreases when the air flow rate increases. The multipass mode test results show that the VOCs are oxidized but additional testing time would be necessary in order to show if they can be fully oxidized. The intermediate reaction products are mainly acetaldehyde and formaldehyde whose amount depends on the challenge VOC. The intermediate reaction products are also oxidized and additional testing time would be necessary in order to show if they can be fully oxidized. The development of this new photocatalytic air filter is still going on. The VOC/odor removing adsorbers are available for only a small proportion of aircraft currently in service. The photocatalytic oxidation (PCO) technique has appeared to be a promising solution to odors problems met in aircraft. This article reports the test results of a new photocatalytic oxidation air filter (PCO unit) designed for aircraft cabin applications. The overall efficiency of the PCO unit is function of the compound (toluene, ethanol, and acetone) that challenges the unit and toluene appears to be the most difficult compound to oxidize. Test results have shown the influence of the design of the PCO unit, the air flow rate and the type of UV on the efficiency of the PCO unit. The results obtained in this study represent a first attempt on the way to design a filter for VOC removal in cabin aircraft applications. The PCO technique used by the tested prototype unit is able to partially oxidized the challenge VOCs but one has to be aware that some harmful intermediate reaction products (mainly formaldehyde and acetaldehyde) are produced during the oxidation process before being partially oxidized too.
General test plan redundant sensor strapdown IMU evaluation program
NASA Technical Reports Server (NTRS)
Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.
1971-01-01
The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.
Light-emitting device test systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCord, Mark; Brodie, Alan; George, James
Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.
Particulate Matter Stack Emission Compliance Test Procedure for Fuel Burning Units.
ERIC Educational Resources Information Center
West Virginia Air Pollution Control Commission, Charleston.
This publication details the particulate matter emissions test procedure that is applicable for conducting compliance tests for fuel burning units required to be tested under Sub-section 7 of Regulation II (1972) as established by the state of West Virginia Air Pollution Control Commission. The testing procedure is divided into five parts:…
Collaborative Test Reviews: Student Performance
ERIC Educational Resources Information Center
Bhatia, Anuradha; Makela, Carole J.
2010-01-01
A group study method proved helpful in improving senior-level students' performance on unit tests through collaborative learning. Students of a History of Textiles course voluntarily attended study sessions to review course content and prepare for unit tests. The students who attended the group reviews scored better on tests than those who did…
10 CFR 429.11 - General sampling requirements for selecting units to be tested.
Code of Federal Regulations, 2012 CFR
2012-01-01
... tested. 429.11 Section 429.11 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.11 General sampling requirements for selecting units to be tested. (a) When testing of covered products or...
2012-11-06
NASA engineers test a chemical steam generator (CSG) unit on the E-2 Test Stand at John C. Stennis Space Center on Nov. 6. The test was one of 27 conducted in Stennis' E Test Complex the week of Nov. 5. Twenty-seven CSG units will be used on the new A-3 Test Stand at Stennis to produce a vacuum that allows testing of engines at simulated altitudes up to 100,000 feet.
NASA Technical Reports Server (NTRS)
Van Dyke, Michael B.
2013-01-01
Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From Sulfur...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2010 CFR
2010-07-01
...) for Carbon Monoxide (CO) 11 Table 11 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 11 Table 11 to Subpart UUU of Part 63—Requirements for Performance Tests for Organic HAP Emissions...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Sulfur Oxides 32 Table 32 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 32 Table 32 to Subpart UUU of Part 63—Requirements for Performance Tests for HAP Emissions From...
Code of Federal Regulations, 2011 CFR
2011-07-01
...) for Carbon Monoxide (CO) 11 Table 11 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 11 Table 11 to Subpart UUU of Part 63—Requirements for Performance Tests for Organic HAP Emissions...
Spacelab interface development test, volume 1, sections 1-6
NASA Technical Reports Server (NTRS)
Harris, L. H.
1979-01-01
Data recorded during the following tests is presented: pulse coded modulator master unit to Spacelab (S/L) interface, master timing unit to S/L interface, multiplexer-demultiplexer/serial input-output to S/L interface, and special tests.
NASA Technical Reports Server (NTRS)
Pines, D.
1998-01-01
Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.
NASA Technical Reports Server (NTRS)
Balch, D. T.; Saccullo, A.; Sheehy, T. W.
1983-01-01
To assist in identifying and quantifying the relevant parameters associated with the complex topic of main rotor/fuselage/tail rotor interference, a model scale hover test was conducted in the Model Rotor Hover Facility. The test was conducted using the basic model test rig, fuselage skins to represent a UH-60A BLACK HAWK helicopter, 4 sets of rotor blades of varying geometry (i.e., twist, airfoils and solidity) and a model tail rotor that could be relocated to give changes in rotor clearance (axially, laterally, and vertically), can't angle and operating model (pusher or tractor). The description of the models and the tests, data analysis and summary (including plots) are included. The customary system of units gas used for principal measurements and calculations. Expressions in both SI units and customary units are used with the SI units stated first and the customary units afterwords, in parenthesis.
Summary of Aquifer Test Data for Arkansas - 1940-2006
Pugh, Aaron L.
2008-01-01
As demands on Arkansas's ground water continue to increase, decision-makers need all available information to ensure the sustainability of this important natural resource. From 1940 through 2006, the U.S. Geological Survey has conducted over 300 aquifer tests in Arkansas. Much of these data never have been published. This report presents the results from 206 of these aquifer tests from 21 different hydrogeologic units spread across 51 Arkansas counties. Ten of the hydrogeologic units are within the Atlantic Plain of Arkansas and consist mostly of unconsolidated and semi-consolidated deposits. The remaining 11 units are within the Interior Highlands consisting mainly of consolidated rock. Descriptive statistics are reported for each hydrologic unit with two or more tests, including the mean, minimum, median, maximum and standard deviation values for specific capacity, transmissivity, hydraulic conductivity, and storage coefficient. Hydraulic conductivity values for the major water-bearing hydrogeologic units are estimated because few conductivity values are recorded in the original records. Nearly all estimated hydraulic conductivity values agree with published hydraulic conductivity values based on the hydrogeologic unit material types. Similarly, because few specific capacity values were available in the original aquifer test records, specific capacity values are estimated for individual wells.
Dapia, Irene; Tong, Hoi Y.; Arias, Pedro; Muñoz, Mario; Tenorio, Jair; Hernández, Rafael; García García, Irene; Gordo, Gema; Ramírez, Elena; Frías, Jesús; Lapunzina, Pablo; Carcas, Antonio J.
2017-01-01
Abstract In 2014, we established a pharmacogenetics unit with the intention of facilitating the integration of pharmacogenetic testing into clinical practice. This unit was centered around two main ideas: i) individualization of clinical recommendations, and ii) preemptive genotyping in risk populations. Our unit is based on the design and validation of a single nucleotide polymorphism (SNP) microarray, which has allowed testing of 180 SNPs associated with drug response (PharmArray), and clinical consultation regarding the results. Herein, we report our experience in integrating pharmacogenetic testing into our hospital and we present the results of the 2,539 pharmacogenetic consultation requests received over the past 3 years in our unit. The results demonstrate the feasibility of implementing pharmacogenetic testing in clinical practice within a national health system. PMID:29193749
Indigenous unit for bending and twisting tests of ultra-thin films on a flexible substrate
NASA Astrophysics Data System (ADS)
D'souza, Slavia Deeksha; Hazarika, Pratim; Prakasarao, Ch Surya; Kovendhan, M.; Kumar, R. Arockia; Joseph, D. Paul
2018-04-01
An indigenous unit is designed to test the stability of thin films deposited on to a flexible substrate by inducing a required number of bending and twisting under specific conditions. The unit is designed using aluminum and automated by sending pulse width modulated signals to servo motors using ATmega328 microcontroller. We have tested the unit by imparting stress on to a commercial ITO film deposited on a PET substrate. After a definite number of bending and twisting cycles, the electrical and surface properties are studied and the results are discussed.
2010-10-27
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is prepared for installation Oct. 24, 2010, at John C. Stennis Space Center. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
2010-10-22
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand arrived at John. C. Stennis Space Center on Oct. 22, 2010. The unit was installed at the E-2 Test Stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Course in Carpentry: Interior Finish. Workbook and Tests.
ERIC Educational Resources Information Center
Strazicich, Mirko, Ed.
Designed for use in carpentry apprenticeship classes, this workbook contains nine units on carpentry skills in the area of interior finish, lists of recommended and required instructional materials, and nine unit tests. Each instructional unit includes a listing of performance statements and text covering skills addressed in individual performance…
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units and lamp voltage. 234.253... Maintenance, Inspection, and Testing Inspections and Tests § 234.253 Flashing light units and lamp voltage. (a... proper alignment and frequency of flashes in accordance with installation specifications. (b) Lamp...
NASA Technical Reports Server (NTRS)
Mason, M. G.
1975-01-01
A simulator is described, which was designed for testing and evaluating inertial measuring units, and flight platforms. Mechanical and electrical specifications for the outer, middle, and inner axis are presented. Test results are included.
Stability tests at Browns Ferry Unit 1 under single-loop operating conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
March-Leuba, J.; Wood, R.T.; Otaduy, P.J.
1986-07-01
The results of neutronic stability tests performed on February 9, 1985, at the Browns Ferry Nuclear Power Plant Unit 1 under single-loop operation (SLO) conditions are documented. The main conclusions of the tests are presented.
Apollo telescope mount thermal systems unit thermal vacuum test
NASA Technical Reports Server (NTRS)
Trucks, H. F.; Hueter, U.; Wise, J. H.; Bachtel, F. D.
1971-01-01
The Apollo Telescope Mount's thermal systems unit was utilized to conduct a full-scale thermal vacuum test to verify the thermal design and the analytical techniques used to develop the thermal mathematical models. Thermal vacuum test philosophy, test objectives configuration, test monitoring, environment simulation, vehicle test performance, and data correlation are discussed. Emphasis is placed on planning and execution of the thermal vacuum test with particular attention on problems encountered in conducting a test of this maguitude.
Agriculture Library of Test Items.
ERIC Educational Resources Information Center
Sutherland, Duncan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
10 CFR 431.325 - Units to be tested.
Code of Federal Regulations, 2011 CFR
2011-01-01
... EQUIPMENT Metal Halide Lamp Ballasts and Fixtures Test Procedures § 431.325 Units to be tested. For each basic model of metal halide lamp ballast selected for testing, a sample of sufficient size, no less than... energy efficiency calculated as the measured output power to the lamp divided by the measured input power...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-29
.... (Mitsubishi) for a similar line of commercial multi-split air-conditioning systems: Testing laboratories...-conditioning systems: (1) Testing laboratories cannot test products with so many indoor units; (2) there are too many possible combinations of indoor and outdoor unit to test. The Daikin VRV-WIII systems have...
Successful completion of a cyclic ground test of a mercury ion auxiliary propulsion system
NASA Technical Reports Server (NTRS)
Francisco, David R.; Low, Charles A., Jr.; Power, John L.
1988-01-01
An engineering model Ion Auxiliary Propulsion System (IAPS) 8-cm thruster (S/N 905) has completed a life test at NASA Lewis Research Center. The mercury ion thruster successfully completed and exceeded the test goals of 2557 on/off cycles and 7057 hr of operation at full thrust. The final 1200 cycles and 3600 hr of the life test were conducted using an engineering model of the IAPS power electronics unit (PEU) and breadboard digital controller and interface unit (DCIU). This portion of the test is described in this paper with a charted history of thruster operating parameters and off-normal events. Performance and operating characteristics were constant throughout the test with only minor variations. The engineering model power electronics unit operated without malfunction; the flight software in the digital controller and interface unit was exercised and verified. Post-test inspection of the thruster revealed facility enhanced accelerator grid erosion but overall the thruster was in good condition. It was concluded that the thruster performance was not drastically degraded by time or cycles. Additional cyclic testing is currently under consideration.
Successful completion of a cyclic ground test of a mercury Ion Auxiliary Propulsion System
NASA Technical Reports Server (NTRS)
Francisco, David R.; Low, Charles A., Jr.; Power, John L.
1988-01-01
An engineering model Ion Auxiliary Propulsion System (IAPS) 8-cm thruster (S/N 905) has completed a life test at NASA Lewis Research Center. The mercury ion thruster successfully completed and exceeded the test goals of 2557 on/off cycles and 7057 hr of operation at full thrust. The final 1200 cycles and 3600 hr of the life test were conducted using an engineering model of the IAPS power electronics unit (PEU) and breadboard digital controller and interface unit (DCIU). This portion of the test is described in this paper with a charted history of thruster operating parameters and off-normal events. Performance and operating characteristics were constant throughout the test with only minor variations. The engineering model power electronics unit operated without malfunction; the flight software in the digital controller and interface unit was exercised and verified. Post-test inspection of the thruster revealed facility enhanced accelerator grid erosion but overall the thruster was in good condition. It was concluded that the thruster performance was not drastically degraded by time or cycles. Additional cyclic testing is currently under consideration.
Martin, Edward J [Virginia Beach, VA
2008-01-15
A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.
Dynamic of small photovoltaic systems
NASA Astrophysics Data System (ADS)
Mehrmann, A.; Kleinkauf, W.; Pigorsch, W.; Steeb, H.
The results of 1.5 yr of field-testing of two photovoltaic (PV) power plants, one equipped with an electrolyzer and H2 storage, are reported. Both systems were interconnected with the grid and featured the PV module, a power conditioning unit, ac and dc load connections, and control units. The rated power of both units was 100 Wp. The system with electrolysis was governed by control laws which maximized the electrolyzer current. The tests underscored the preference for a power conditioning unit, rather than direct output to load connections. A 1 kWp system was developed in a follow-up program and will be tested in concert with electrolysis and interconnection with several grid customers. The program is geared to eventual development of larger units for utility-size applications.
XM587E2/XM724 Electronic Time Fuzes: Developmental Test/Operational Test (DT/OT) II Test Phase
1979-11-01
unit - da.- aged setbac* spring Sunit - damAged setback pia 140 .4 C) Twenty-five units were subjected to variable testing "to determine tho G level...SAXIP ACCEPT REJECT NO. Ttf7l KSCRIFTI( AG sin4 go flj-. cEI~ *S-FOOTMOP TEsT o 0 (DROPPED IN FIVE DIFFRNT csIllvrATIaNS -- 1 PER OCRIMP... ascue bya i i*ctet FAILURE AND ACTION REPORT 71134 Jj 7113 .I ,...,-... 7 wow o ft.-I I The unIt will not tht. bte the the scalet inpf t to the.uner h
González, Rocio; Echevarria, José Manuel; Avellón, Ana; Barea, Luisa; Castro, Emma
2006-07-01
Mathematical models predict that, in Spain, a significant number of blood units will be obtained during the window period of the hepatitis B virus (HBV) infection. Routine nucleic acid testing (NAT) on individual blood units may provide experimental data to evaluate such a theoretical risk. Between February and July 2005, a total of 34,631 individual units were screened for HBV DNA by a multiplex transcription-mediated amplification (TMA) test. Units that repeatedly reacted in the test, but did not react for HBV surface antigen (HBsAg), were submitted to additional testing by both molecular and conventional assays, and the donors were recalled for follow-up studies and the collection of clinical and epidemiologic data. Confirmatory testing and follow-up studies identified 2 blood units donated during the HBV infection window period (1/17,316 units studied). Sequencing of amplification products obtained by nested polymerase chain reaction (n-PCR) revealed two HBV strains from genotypes D/ayw3 and F/adw4q-, but did not identify HBsAg mutants. The HBV DNA concentration in the index donations was estimated to be below the n-PCR detection level (180 IU/mL), in both cases. One donor developed acute hepatitis 2 months after donating blood, but the other remained asymptomatic and displayed normal alanine aminotransferase levels at follow-up. The HBV infection window period is a real issue in the setting of Spanish blood transfusions. NAT of individual units by TMA would make a significant contribution to improving the safety of the blood supply in Spain. Additional studies involving a larger number of units and longer periods of time are required, however, to ascertain the true incidence of the problem in this country.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bickes, R.W. Jr.; Wackerbarth, D.E.; Mohler, J.H.
1996-12-31
The authors report on recent studies comparing the ignition threshold of temperature cycled, SCB thermite devices with units that were not submitted to temperature cycling. Aluminum/copper-oxide thermite was pressed into units at two densities, 45% of theoretical maximum density (TMD) or 47% of TMD. Half of each of the density sets underwent three thermal cycles; each cycle consisted of 2 hours at 74 C and 2 hours at {minus}54 C, with a 5 minute maximum transfer time between temperatures. The temperature cycled units were brought to ambient temperature before the threshold testing. Both the density and the thermal cycling affectedmore » the all-fire voltage. Using a 5.34 {micro}F CDU (capacitor discharge unit) firing set, the all-fire voltage for the units that were not temperature cycled increased with density from 32.99 V (45% TMD) to 39.32 V (47% TMD). The all-fire voltages for the thermally cycled units were 34.42 V (45% TMD) and 58.1 V (47% TMD). They also report on no-fire levels at ambient temperature for two component designs; the 5 minute no-fire levels were greater than 1.2 A. Units were also subjected to tests in which 1 W of RF power was injected into the bridges at 10 MHz for 5 minutes. The units survived and fired normally afterwards. Finally, units were subjected to pin-to-pin electrostatic discharge (ESD) tests. None of the units fired upon application of the ESD pulse, and all of the tested units fired normally afterwards.« less
Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.
Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't
2017-04-01
Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.
Cox, Louis Anthony; Popken, Douglas A; VanSickle, John J; Sahu, Ranajit
2005-08-01
The U.S. Department of Agriculture (USDA) tests a subset of cattle slaughtered in the United States for bovine spongiform encephalitis (BSE). Knowing the origin of cattle (U.S. vs. Canadian) at testing could enable new testing or surveillance policies based on the origin of cattle testing positive. For example, if a Canadian cow tests positive for BSE, while no U.S. origin cattle do, the United States could subject Canadian cattle to more stringent testing. This article illustrates the application of a value-of-information (VOI) framework to quantify and compare potential economic costs to the United States of implementing tracking cattle origins to the costs of not doing so. The potential economic value of information from a tracking program is estimated to exceed its costs by more than five-fold if such information can reduce future losses in export and domestic markets and reduce future testing costs required to reassure or win back customers. Sensitivity analyses indicate that this conclusion is somewhat robust to many technical, scientific, and market uncertainties, including the current prevalence of BSE in the United States and/or Canada and the likely reactions of consumers to possible future discoveries of BSE in the United States and/or Canada. Indeed, the potential value of tracking information is great enough to justify locating and tracking Canadian cattle already in the United States when this can be done for a reasonable cost. If aggressive tracking and testing can win back lost exports, then the VOI of a tracking program may increase to over half a billion dollars per year.
Water Ingestion into Axial Flow Compressors. Part III. Experimental Results and Discussion
1981-10-01
total pressure, static pressure, and temperature at both compressor inlet and outlet. A United Sensor model PDC-12-G-l0-KL pitot-static pressure probe...Test Compressor inlet and outlet temperatures during water injection tests: United Sensor and Control Corp. type TK-8-CiA-36’-F Aspirate...ured utilizing standard aspirated thermocouples, namely an United Sensor and Control Corp. type TK-8-C/A-36-F. The Test Compressor out- let
Water absorption characteristic of interlocking compressed earth brick units
NASA Astrophysics Data System (ADS)
Bakar, B. H. Abu; Saari, S.; Surip, N. A.
2017-10-01
This study aims to investigate the water absorption characteristic of interlocking compressed earth brick (ICEB) units. Apart from compressive strength, water absorption is an important property in masonry. This property can affect the quality of the brick itself and the bond strength between the brick and mortar in masonry structures and can result in reducing its strength properties. The units were tested for 24 h water absorption and 5 h boiling water absorption. A total of 170 ICEB units from four ICEB types underwent both tests. For the 24 h water absorption, the ICEB units were dried in the oven for 24 h and then cooled before being weighed. Thereafter, each brick was immersed in water for 24 h and weighed. The same specimens used for the 24 h water absorption test were re-used for the 5 h boiling water absorption test. After completing the 24 h water absorption test, the brick was boiled for 5-hours and weighed. The highest water absorption for the ICEBs in the 24-hour water absorption and 5 h boiling water absorption tests are 15.09% and 17.18%, respectively. The half brick has the highest water absorption (15.87%), whereas the beam brick has the lowest (13.20%). The water absorption of an ICEB unit is higher than that of normal bricks, although the water absorption of the former remains below the maximum rate of the brick water absorption (21%).
Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo
2017-01-01
Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family physicians. Approaches to ensuring more rational testing are needed. PMID:29146654
Distribution of indoor radon concentrations in Pennsylvania, 1990-2007
Gross, Eliza L.
2013-01-01
Median indoor radon concentrations aggregated according to geologic units and hydrogeologic settings are useful for drawing general conclusions about the occurrence of indoor radon in specific geologic units and hydrogeologic settings, but the associated data and maps have limitations. The aggregated indoor radon data have testing and spatial accuracy limitations due to lack of available information regarding testing conditions and the imprecision of geocoded test locations. In addition, the associated data describing geologic units and hydrogeologic settings have spatial and interpretation accuracy limitations, which are a result of using statewide data to define conditions at test locations and geologic data that represent a broad interpretation of geologic units across the State. As a result, indoor air radon concentration distributions are not proposed for use in predicting individual concentrations at specific sites nor for use as a decision-making tool for property owners to decide whether to test for indoor radon concentrations at specific property locations.
Plated wire random access memories
NASA Technical Reports Server (NTRS)
Gouldin, L. D.
1975-01-01
A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.
A PLAN FOR FIELD TESTING R/I UNITS.
ERIC Educational Resources Information Center
WARDROP, JAMES L.; AND OTHERS
THIS PAPER DISCUSSES THE FIELD TESTING OF RESEARCH AND INSTRUCTION UNITS IN OPERATION IN A NUMBER OF WISCONSIN SCHOOLS. THE UNIT IS A REORGANIZED SCHOOL STRUCTURE WHICH IS MADE UP OF A LEARNING SPECIALIST LEADER, TEACHERS, PARAPROFESSIONALS, AND STUDENTS. THE MAJOR AIMS OF THIS EDUCATIONAL INNOVATION ARE (1) TO DEVELOP AND MAINTAIN AN…
Introduction to Production/Manufacturing Drafting. Drafting Module 8. Instructor's Guide.
ERIC Educational Resources Information Center
Missouri Univ., Columbia. Instructional Materials Lab.
This module, 1 of 10 in the Drafting curriculum guide developed in Missouri, contains 3 units of study that include some or all of the following components: performance objectives, lesson plans, information sheets, transparency masters, handouts, assignment sheets, job sheets, a unit test, and answers to the unit test. Special instructions on…
Major Appliance Repair. Teacher Edition and Student Edition. Second Edition.
ERIC Educational Resources Information Center
Smreker, Gene; Calvert, King
This second edition contains teacher and student guides for 14 units of instruction in major appliance repair. Each unit in the teacher edition includes some or all of the following basic components: objective sheet, suggested activities, answers to assignment sheets, answers to the written test, written test, a unit evaluation form, teacher…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
Eddy-Current Detection of Weak Bolt Heads
NASA Technical Reports Server (NTRS)
Messina, C. P.
1987-01-01
Electronic test identifies flawed units passing hardness tests. Eddy-current test detects weakness in head-to-shank junctions of 1/4-28 cup-washer lock bolts. Developed for alloy A286 steel bolts in Space Shuttle main engine fuel turbo-pump. Test examines full volume of head, including head-to-shank transition and nondestructively screens out potentially defective units. Test adapts to any other alloys.
Testing for purchasing power parity in 21 African countries using several unit root tests
NASA Astrophysics Data System (ADS)
Choji, Niri Martha; Sek, Siok Kun
2017-04-01
Purchasing power parity is used as a basis for international income and expenditure comparison through the exchange rate theory. However, empirical studies show disagreement on the validity of PPP. In this paper, we conduct the testing on the validity of PPP using panel data approach. We apply seven different panel unit root tests to test the validity of the purchasing power parity (PPP) hypothesis based on the quarterly data on real effective exchange rate for 21 African countries from the period 1971: Q1-2012: Q4. All the results of the seven tests rejected the hypothesis of stationarity meaning that absolute PPP does not hold in those African Countries. This result confirmed the claim from previous studies that standard panel unit tests fail to support the PPP hypothesis.
Thermal vacuum life test facility for radioisotope thermoelectric generators
NASA Astrophysics Data System (ADS)
Deaton, R. L.; Goebel, C. J.; Amos, W. R.
In the late 1970's, the Department of Energy (DOE) assigned Monsanto Research Corporation, Mound Facility, now operated by EG and G Mound Applied Technologies, the responsibility for assembling and testing General Purpose Heat Source (GPHS) radioisotope thermoelectric generators (RTGs). Assembled and tested were five RTGs, which included four flight units and one non-flight qualification unit. Figure 1 shows the RTG, which was designed by General Electric AstroSpace Division (GE/ASD) to produce 285 W of electrical power. A detailed description of the processes for RTG assembly and testing is presented by Amos and Goebel (1989). The RTG performance data are described by Bennett, et al., (1986). The flight units will provide electrical power for the National Aeronautics and Space Administration's (NASA) Galileo mission to Jupiter (two RTGs) and the joint NASA/European Space Agency (ESA) Ulysses mission to study the polar regions of the sun (one RTG). The remaining flight unit will serve as the spare for both missions, and a non-flight qualification unit was assembled and tested to ensure that performance criteria were adequately met.
Multichannel electrochemical microbial detection unit
NASA Technical Reports Server (NTRS)
Wilkins, J. R.; Young, R. N.; Boykin, E. H.
1978-01-01
The paper describes the design and capabilities of a compact multichannel electrochemical unit devised to detect and automatically indicate detection time length of bacteria. By connecting this unit to a strip-chart recorder, a permanent record is obtained of the end points and growth curves for each of eight channels. The experimental setup utilizing the multichannel unit consists of a test tube (25 by 150 mm) containing a combination redox electrode plus 18 ml of lauryl tryptose broth and positioned in a 35-C water bath. Leads from the electrodes are connected to the multichannel unit, which in turn is connected to a strip-chart recorder. After addition of 2.0 ml of inoculum to the test tubes, depression of the push-button starter activates the electronics, timer, and indicator light for each channel. The multichannel unit is employed to test tenfold dilutions of various members of the Enterobacteriaceae group, and a typical dose-response curve is presented.
NASA Astrophysics Data System (ADS)
Pang, Zuobo; Zhou, Hong; Xie, Guofeng; Cong, Dalong; Meng, Chao; Ren, Luquan
2015-07-01
In order to get close to the wear form of guide rails, the homemade linear reciprocating wear testing machine was used for the wear test. In order to improve the wear-resistance of gray cast iron guide rail, bionic coupling units of different forms were manufactured by a laser. Wear behavior of gray-cast-iron with bionic-coupling units has been studied under dry sliding condition at room temperature using the wear testing machine. The wear resistance was evaluated by means of weight loss measurement and wear morphology. The results indicated that bionic coupling unit could improve the wear resistance of gray cast iron. The wear resistance of gray cast iron with reticulation bionic coupling unit is the best. When the load and speed changed, reticulation bionic coupling unit still has excellent performance in improving the wear resistance of gray cast iron.
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2012 CFR
2012-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing
Code of Federal Regulations, 2014 CFR
2014-07-01
... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...
Geography Library of Test Items. Volume Four.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Home Science Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Smith, Jan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
Languages Library of Test Items. Volume Two: German, Latin.
ERIC Educational Resources Information Center
Campbell, Thomas; And Others
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Languages Library of Test Items. Volume One: French, Indonesian.
ERIC Educational Resources Information Center
Campbell, Thomas; And Others
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Three.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Commerce Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Meeve, Brian, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Five.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Textiles and Design Library of Test Items. Volume I.
ERIC Educational Resources Information Center
Smith, Jan, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection is reviewed for content validity and reliability. The test…
Commerce Library of Test Items. Volume Two.
ERIC Educational Resources Information Center
Meeve, Brian, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography Library of Test Items. Volume Six.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Geography: Library of Test Items. Volume II.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Accounting Clerk Guide, Test Packet--Part I.
ERIC Educational Resources Information Center
Foster, Brian; And Others
The test packet is part of an eight volume unit for grades 10, 11, and 12, designed for individualized progression in preparing students for entry into the occupation of accounting clerk. The test packet contains both pretests and post-tests for lessons 1 through 12. The unit is concerned with the basic accounting theory found in the accounting…
United States History. Annotated Bibliography of Tests.
ERIC Educational Resources Information Center
Educational Testing Service, Princeton, NJ. Test Collection.
The 33 tests in this bibliography cover United States History from the period of exploration of the continent through the Civil War to Post World War II. One test measures knowledge of African American history. Types of measures include credit by examination, item banks, and end-of-course tests. All ages are represented but the majority of tests…
NASA Technical Reports Server (NTRS)
Heffner, R. J.
1998-01-01
This is the Engineering Test Report, AMSU-AL METSAT Instrument (S/N 105) Qualification Level Vibration Tests of December 1998 (S/0 605445, OC-419), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
NASA Technical Reports Server (NTRS)
Valdez, A.
2000-01-01
This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A1, S/N 109, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
Geography Library of Test Items. Volume One.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
NASA Technical Reports Server (NTRS)
Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.
1991-01-01
Power components hardware in support of the Space Station Freedom dc Electrical Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switchmode converter, and a switching full-bridge forward converter. The topology, operation principles, and tests results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.
LONG-TERM DEMONSTRATION OF SORBENT ENHANCEMENT ADDITIVE TECHNOLOGY FOR MERCURY CONTROL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jason D. Laumb; Dennis L. Laudal; Grant E. Dunham
2011-05-27
Long-term demonstration tests of advanced sorbent enhancement additive (SEA) technologies have been completed at five coal-fired power plants. The targeted removal rate was 90% from baseline conditions at all five stations. The plants included Hawthorn Unit 5, Mill Creek Unit 4, San Miguel Unit 1, Centralia Unit 2, and Hoot Lake Unit 2. The materials tested included powdered activated carbon, treated carbon, scrubber additives, and SEAs. In only one case (San Miguel) was >90% removal not attainable. The reemission of mercury from the scrubber at this facility prevented >90% capture.
Flight prototype regenerative particulate filter system development
NASA Technical Reports Server (NTRS)
Green, D. C.; Garber, P. J.
1974-01-01
The effort to design, fabricate, and test a flight prototype Filter Regeneration Unit used to regenerate (clean) fluid particulate filter elements is reported. The design of the filter regeneration unit and the results of tests performed in both one-gravity and zero-gravity are discussed. The filter regeneration unit uses a backflush/jet impingement method of regenerating fluid filter elements that is highly efficient. A vortex particle separator and particle trap were designed for zero-gravity use, and the zero-gravity test results are discussed. The filter regeneration unit was designed for both inflight maintenance and ground refurbishment use on space shuttle and future space missions.
NASA Astrophysics Data System (ADS)
Kaszeta, W. J.
1982-12-01
One of the primary obstacles to the application of vaccination in developing countries is the lack of refrigerated storage. Vaccines exposed to elevated temperatures suffer a permanent loss of potency. Photovoltaic (PV) powered refrigerator/freezer (R/F) units could surmount the problem of refrigeration in remote areas where no reliable commercial power supply is available. The performance measurements of two different models of PV powered R/F units for medical use are presented. Qualification testing consisted of four major procedures: no-load pull down, ice making, steady-state (maintenance), and holdover. Both R/F units met the major World Health Organization (WHO) requirements. However, the testing performed does not provide complete characterization of the two units; such information could be derived only from further extensive test procedures.
NASA Technical Reports Server (NTRS)
Kaszeta, W. J.
1982-01-01
One of the primary obstacles to the application of vaccination in developing countries is the lack of refrigerated storage. Vaccines exposed to elevated temperatures suffer a permanent loss of potency. Photovoltaic (PV) powered refrigerator/freezer (R/F) units could surmount the problem of refrigeration in remote areas where no reliable commercial power supply is available. The performance measurements of two different models of PV powered R/F units for medical use are presented. Qualification testing consisted of four major procedures: no-load pull down, ice making, steady-state (maintenance), and holdover. Both R/F units met the major World Health Organization (WHO) requirements. However, the testing performed does not provide complete characterization of the two units; such information could be derived only from further extensive test procedures.
Design, construction, and testing of a five active axes magnetic bearing system
NASA Technical Reports Server (NTRS)
Delprete, Cristiana; Genta, Giancarlo; Carabelli, Stefano
1994-01-01
A high speed electric spindle based on active electromagnetic suspension technology has been designed, built, and tested. The main goal of the research work was the construction of a highly modular unit which can be used for teaching and research purposes. The design of the electromechanical components and of the control unit is described in detail, together with the characterization tests performed on the various subsystems. A description of the preliminary tests on the unit, conducted at speeds not in excess of the first deformation critical speed of the rotor, concludes the work.
2010-10-27
The first of nine chemical steam generator (CSG) units that will be used on the A-3 Test Stand is hoisted into place at the E-2 Test Stand at John C. Stennis Space Center on Oct. 24, 2010. The unit was installed at the E-2 stand for verification and validation testing before it is moved to the A-3 stand. Steam generated by the nine CSG units that will be installed on the A-3 stand will create a vacuum that allows Stennis operators to test next-generation rocket engines at simulated altitudes up to 100,000 feet.
Multiple Hollow Cathode Wear Testing for the Space Station Plasma Contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1994-01-01
A wear test of four hollow cathodes was conducted to resolve issues associated with the Space Station plasma contactor. The objectives of this test were to evaluate unit-to-unit dispersions, verify the transportability of contamination control protocols developed by the project, and to evaluate cathode contamination control and activation procedures to enable simplification of the gas feed system and heater power processor. These objectives were achieved by wear testing four cathodes concurrently to 2000 hours. Test results showed maximum unit-to-unit deviations for discharge voltages and cathode tip temperatures to be +/-3 percent and +/-2 percent, respectively, of the nominal values. Cathodes utilizing contamination control procedures known to increase cathode lifetime showed no trends in their monitored parameters that would indicate a possible failure, demonstrating that contamination control procedures had been successfully transferred. Comparisons of cathodes utilizing and not utilizing a purifier or simplified activation procedure showed similar behavior during wear testing and pre- and post-test performance characterizations. This behavior indicates that use of simplified cathode systems and procedures is consistent with long cathode lifetimes.
Ground test challenges in the development of the Space Shuttle orbiter auxiliary power unit
NASA Technical Reports Server (NTRS)
Chaffee, N. H.; Lance, R. J.; Weary, D. P.
1984-01-01
A conventional aircraft hydraulic system design approach was selected to provide fluid power for the Space Shuttle Orbiter. Developing the power unit, known as the Auxiliary Power Unit (APU), to drive the hydraulic pumps presented a major technological challenge. A small, high speed turbine drive unit powered by catalytically decomposed hydrazine and operating in the pulse mode was selected to meet the requirement. Because of limitations of vendor test facilities, significant portions of the development, flight qualification, and postflight anomaly testing of the Orbiter APU were accomplished at the Johnson Space Center (JSC) test facilities. This paper discusses the unique requirements of attitude, gravity forces, pressure profiles, and thermal environments which had to be satisfied by the APU, and presents the unique test facility and simulation techniques employed to meet the ground test requirements. In particular, the development of the zero-g lubrication system, the development of necessary APU thermal control techniques, the accomplishment of integrated systems tests, and the postflight investigation of the APU lube oil cooler behavior are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, J.E.; Whisnant, R.B.
The report provides an in-depth evaluation of an ultraviolet (UV) disinfection unit as applied to the treatment of cooling water in a textile air washer system. The UV unit tests used a teflon tube to transport the aquatic phase. The unit reduced microbial populations and maintained an average level of 10,000 Colony formed unites/mL for the 6-month testing period, without the addition of biocides. No cleaning or other maintenance was required of the wetted surfaces during the testing period. Slime deposits observed on walls of the air washer during chemical treatment were also eliminated. The UV unit can be utilizedmore » on both cooling towers and air washers without extensive installation.« less
Heat Pump Water Heater Durabliltiy Testing - Phase II
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, VAND.
2004-05-29
Ten heat pump water heaters (HPWH) were placed in an environmentally controlled test facility and run through a durability test program of approximately 7300 duty cycles (actual cycles accumulated ranged from 6640 to 8324 for the ten units). Five of the units were upgraded integral types (HPWH mounted on storage tank, no pump) from the same manufacturer as those tested in our first durability program in 2001 (Baxter and Linkous, 2002). The other five were ''add-on'' type units (HPWH with circulation pump plumbed to a separate storage tank) from another manufacturer. This durability test was designed to represent approximately 7-10more » years of normal operation to meet the hot water needs of a residence. The integral units operated without incident apart from two control board failures. Both of these were caused by inadvertent exposure to very hot and humid (>135 F dry bulb and >120 F dew point) conditions that occurred due to a test loop failure. It is not likely that any residential water heater would be installed where such conditions were expected so these failures are not considered a long-term reliability concern. Two of the integral HPWHs featured a condensate management system (CMS) option that effectively eliminated any need for an evaporator condensate drain, but imposed significant efficiency penalties when operating in high humidity ambient conditions. The add-on units experienced no operational failures (breakdowns with loss of hot water production) during the course of the testing. However, their control systems exhibited some performance degradation under the high temperature, high humidity test conditions--HPWHs would shut off with tank water temperatures 15-20 F lower than when operating under moderate ambient conditions. One unit developed a refrigerant leak during the test program and lost about 50% of its charge resulting in reduced efficiency. Efficiency measurements on all the integral units and four of the add-on units showed significantly higher efficiencies than conventional electric water heaters (EWH). DOE Simulated Use Tests conducted prior to starting the durability testing resulted in energy factors (EF) of about 2.3 for the integral design and 1.4 for the add-on design compared to the minimum value of 0.86 prescribed for EWHs. Based on the experience from this and the previous durability testing, there is no evidence that strongly suggests that any of the HPWHs suffered significant performance degradation after undergoing over 7000 water heat cycles.« less
Economic and workflow analysis of a blood bank automated system.
Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup
2013-07-01
This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.
Engineering Test and Evaluation During High G. Volume III, Anti-G Suits.
1978-06-01
items are: 3 inservice units from USAF and IJSN; an RAF unit; and 2 experimental units (lower body full pressure, and capstan). The study of the capstan...inspections are performed by life-support techni- cians whose training and expertise best enable them to evaluate the anti-G suit condition. The TEHG...of testing in one minute." At some installations this test has been waived by USAF Air Training Command (ATC) to "l psig drop from 5 psig in 20 sec
Lithium-Ion Cell Charge-Control Unit Developed
NASA Technical Reports Server (NTRS)
Reid, Concha M.; Manzo, Michelle A.; Buton, Robert M.; Gemeiner, Russel
2005-01-01
A lithium-ion (Li-ion) cell charge-control unit was developed as part of a Li-ion cell verification program. This unit manages the complex charging scheme that is required when Li-ion cells are charged in series. It enables researchers to test cells together as a pack, while allowing each cell to charge individually. This allows the inherent cell-to-cell variations to be addressed on a series string of cells and reduces test costs substantially in comparison to individual cell testing.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-03
...The U.S. Nuclear Regulatory Commission (NRC or the Commission) is issuing a revision to Regulatory Guide (RG) 1.52, ``Design, Inspection, and Testing Criteria for Air Filtration and Adsorption Units of Post-accident Engineered-Safety-Feature Atmosphere Cleanup Systems in Light-Water-Cooled Nuclear Power Plants.'' This guide applies to the design, inspection, and testing of air filtration and iodine adsorption units of engineered-safety-feature (ESF) atmosphere cleanup systems in light-water-cooled nuclear power plants.
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
Lindley, Patricia A.; Bartram, Dave
2012-01-01
In this article, we present the background to the development of test reviewing by the British Psychological Society (BPS) in the United Kingdom. We also describe the role played by the BPS in the development of the EFPA test review model and its adaptation for use in test reviewing in the United Kingdom. We conclude with a discussion of lessons…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items are made available to teachers for the construction of unit tests or term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The test items meet syllabus…
Nursing workload in public and private intensive care units
Nogueira, Lilia de Souza; Koike, Karina Mitie; Sardinha, Débora Souza; Padilha, Katia Grillo; de Sousa, Regina Marcia Cardoso
2013-01-01
Objective This study sought to compare patients at public and private intensive care units according to the nursing workload and interventions provided. Methods This retrospective, comparative cohort study included 600 patients admitted to 4 intensive care units in São Paulo. The nursing workload and interventions were assessed using the Nursing Activities Score during the first and last 24 hours of the patient's stay at the intensive care unit. Pearson's chi-square test, Fisher's exact test, the Mann-Whitney test, and Student's t test were used to compare the patient groups. Results The average Nursing Activities Score upon admission to the intensive care unit was 61.9, with a score of 52.8 upon discharge. Significant differences were found among the patients at public and private intensive care units relative to the average Nursing Activities Score upon admission, as well as for 12 out of 23 nursing interventions performed during the first 24 hours of stay at the intensive care units. The patients at the public intensive care units exhibited a higher average score and overall more frequent nursing interventions, with the exception of those involved in the "care of drains", "mobilization and positioning", and "intravenous hyperalimentation". The groups also differed with regard to the evolution of the Nursing Activities Score among the total case series as well as the groups of survivors from the time of admission to discharge from the intensive care unit. Conclusion Patients admitted to public and private intensive care units exhibit differences in their nursing care demands, which may help managers with nursing manpower planning. PMID:24213086
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
30 CFR 74.14 - Certificate of approval.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... (a) Upon completion of the testing of a CMDPSU or the pump unit or after review of testing protocols... unless MSHA has first issued a certificate of approval for either the pump unit of a CMDPSU or for the... the CMDPSU and the pump unit, or of the CPDM, as appropriate, upon which the certificate of approval...
29 CFR 1919.28 - Unit proof tests-cranes and gear accessory thereto.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Unit proof tests-cranes and gear accessory thereto. 1919.28... Loads; Heat Treatment; Competent Persons § 1919.28 Unit proof tests—cranes and gear accessory thereto. (a) Except as noted in paragraph (e) of this section, cranes and other hoisting machines, together...
[Arizona] Field Test Report. Vol. 10. Learn to Earn. 1974-75.
ERIC Educational Resources Information Center
Small, Charles; And Others
The field test report on the "Learn to Earn" instructional unit for grade 6 is one of a series of reports on the Arizona developed Career Education Curriculum Units. Presented is specific information as to the success of the units in terms of the learner's cognitive, affective, and psychomotor behavior according to expressed performance…
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2012 CFR
2012-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2014 CFR
2014-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2013 CFR
2013-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION... Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As...
Potency Determination of Antidandruff Shampoos in Nystatin International Unit Equivalents
Anusha Hewage, D. B. G.; Pathirana, W.; Pinnawela, Amara
2008-01-01
A convenient standard microbiological potency determination test for the antidandruff shampoos was developed by adopting the pharmacopoeial microbiological assay procedure of the drug nystatin. A standard curve was drawn consisting of the inhibition zone diameters vs. logarithm of nystatin concentrations in international units using the fungus Saccharomyces cerevisiae (yeast) strain National Collection of Type Culture (NCTC) 1071606 as the test organism. From the standard curve the yeast inhibitory potencies of the shampoos in nystatin international unit equivalents were determined from the respective inhibition zones of the test samples of the shampoos. Under test conditions four shampoo samples showed remarkable fungal inhibitory potencies of 10227, 10731, 12396 and 18211 nystatin international unit equivalents/ml while two shampoo samples had extremely feeble inhibitory potencies 4.07 and 4.37 nystatin international unit equivalents/ml although the latter two products claimed antifungal activity. The potency determination method could be applied to any antidandruff shampoo with any one or a combination of active ingredients. PMID:21394271
Meini, Genny; Dello Russo, Cinzia; Allice, Tiziano; Barresi, Renata; D'Arrigo, Roberta; Falasca, Francesca; Lipsi, Maria Rosaria; Paolucci, Stefania; Zanussi, Stefania; Antonetti, Raffaele; Baldanti, Fausto; Basaglia, Giancarlo; Bruzzone, Bianca; Polilli, Ennio; Ghisetti, Valeria; Pucillo, Leopoldo Paolo; Turriziani, Ombretta; Pirazzoli, Antonella; Navarra, Pierluigi; Zazzi, Maurizio
2016-05-01
Since the HLA-B*57:01 allele is strongly associated with abacavir hypersensitivity reaction, testing for the presence of HLA-B*57:01 is mandatory before administration of abacavir. While HLA-B*57:01 testing is usually provided by pharmacogenetics, genetics or blood transfusion services, clinical virology laboratories can be an optimal opportunity for HLA-B*57:01 testing since they receive blood samples for routine HIV monitoring and have the expertise for convenient and less expensive PCR-based point mutation assays. The Italian HLA-B*57:01 Network gathers accredited clinical virology laboratories offering HLA-B*57:01 testing in Italy with the aim to share protocols, test new methods, develop and maintain external quality assurance (EQA) programs. A panel of 9HLA-B*57:01-positive and 16HLA-B*57:01-negative frozen blood samples were blindly distributed to 10 units including 9 clinical virology laboratories and one reference pharmacology laboratory. Each laboratory was free to use its own routine method for DNA extraction and HLA-B*57:01 testing. DNA was extracted by automated workstations in 6 units and by manual spin columns in 4. Eight units used the Duplicα Real Time HLA-B*57:01 kit by Euroclone and two units used two different PCR homemade protocols. All the 10 units correctly identified all the 25 samples. The first HLA-B*57:01 EQA program run in Italy showed that clinical virology units are equipped and proficient for providing HLA-B*57:01 testing by inexpensive assays easy to integrate into their routine. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Heffner, R.
2000-01-01
This is the Engineering Test Report, AMSU-A2 METSAT Instrument (S/N 108) Acceptance Level Vibration Test of Dec 1999/Jan 2000 (S/O 784077, OC-454), for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
NASA Technical Reports Server (NTRS)
Valdez, A.
2000-01-01
This is the Engineering Test Report, Radiated Emissions and SARR, SARP, DCS Receivers, Link Frequencies EMI Sensitive Band Test Results, AMSU-A2, S/N 108, for the Integrated Advanced Microwave Sounding Unit-A (AMSU-A).
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-29
...] Advancing the Development of Diagnostic Tests and Biomarkers for Tuberculosis; Public Workshop; Request for... workshop entitled ``Advancing the Development of Diagnostic Tests and Biomarkers for Tuberculosis (TB... Tuberculosis in the United States, Committee on the Elimination of Tuberculosis in the United States, Division...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-29
... Treatment, Heating Ventilation and Air Conditioning Systems.'' This new standard provides comprehensive test... Criteria for Air Filtration and Adsorption Units of Normal Atmosphere Cleanup Systems in Light-Water-Cooled... NUCLEAR REGULATORY COMMISSION [NRC-2012-0152] Design, Inspection, and Testing Criteria for Air...
This Federal Radiation Council report includes a full study and analysis of fallout expected in 1963 from nuclear testing that occurred in the past. This report covers fallout expected from Soviet and United States tests through 1962.
Which Fecal Immunochemical Test Should I Choose?
Daly, Jeanette M.; Xu, Yinghui; Levy, Barcey T.
2017-01-01
Objectives: To summarize the fecal immunochemical tests (FITs) available in the United States, the 2014 pathology proficiency testing (PT) program FIT results, and the literature related to the test characteristics of FITs available in the United States to detect advanced adenomatous polyps (AAP) and/or colorectal cancer (CRC). Methods: Detailed review of the Food and Drug Administration’s Clinical Laboratory Improvement Amendments (CLIA) database of fecal occult blood tests, the 2014 FIT PT program results, and the literature related to FIT accuracy. Results: A search of the CLIA database identified 65 FITs, with 26 FITs available for purchase in the United States. Thirteen of these FITs were evaluated on a regular basis by PT programs, with an overall sensitivity of 99.1% and specificity of 99.2% for samples spiked with hemoglobin. Automated FITs had better sensitivity and specificity than CLIA-waived FITs for detection of AAP and CRC in human studies using colonoscopy as the gold standard. Conclusion: Although many FITs are available in the United States, few have been tested in proficiency testing programs. Even fewer have data in humans on sensitivity and specificity for AAP or CRC. Our review indicates that automated FITs have the best test characteristics for AAP and CRC. PMID:28447866
Commercial landscape of noninvasive prenatal testing in the United States.
Agarwal, Ashwin; Sayres, Lauren C; Cho, Mildred K; Cook-Deegan, Robert; Chandrasekharan, Subhashini
2013-06-01
Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times, and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers, and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. © 2013 John Wiley & Sons, Ltd.
Commercial Landscape of noninvasive prenatal testing in the United States
Agarwal, Ashwin; Sayres, Lauren C.; Cho, Mildred K.; Cook-Deegan, Robert; Chandrasekharan, Subhashini
2014-01-01
Cell-free fetal DNA-based noninvasive prenatal testing (NIPT) could significantly change the paradigm of prenatal testing and screening. Intellectual property (IP) and commercialization promise to be important components of the emerging debate about clinical implementation of these technologies. We have assembled information about types of testing, prices, turnaround times and reimbursement of recently launched commercial tests in the United States from the trade press, news articles, and scientific, legal, and business publications. We also describe the patenting and licensing landscape of technologies underlying these tests and ongoing patent litigation in the United States. Finally, we discuss how IP issues may affect clinical translation of NIPT and their potential implications for stakeholders. Fetal medicine professionals (clinicians and researchers), genetic counselors, insurers, regulators, test developers and patients may be able to use this information to make informed decisions about clinical implementation of current and emerging noninvasive prenatal tests. PMID:23686656
Oximeter reliability in a subzero environment.
Macnab, A J; Smith, M; Phillips, N; Smart, P
1996-11-01
Pulse oximeters optimize care in the pre-hospital setting. As British Columbia ambulance teams often provide care in subzero temperatures, we conducted a study to determine the reliability of 3 commercially-available portable oximeters in a subzero environment. We hypothesized that there is no significant difference between SaO2 readings obtained using a pulse oximeter at room temperature and a pulse oximeter operating at sub-zero temperatures. Subjects were stable normothermic children in intensive care on Hewlett Packard monitors (control unit) at room temperature. The test units were packed in dry ice in an insulated bin (temperature - 15 degrees C to -30 degrees C) and their sensors placed on the subjects, contralateral to the control sensors. Data were collected simultaneously from test and control units immediately following validation of control unit values by co-oximetry (blood gas). No data were unacceptable. Two units (Propaq 106EC and Nonin 8500N) functioned well to < -15 degrees C, providing data comparable to those obtained from the control unit (p < 0.001). The Siemens Micro O2 did not function at the temperatures tested. Monitor users who require equipment to function in subzero environments (military, Coast Guard, Mountain Rescue) should ensure that function is reliable, and could test units using this method.
Pilot-scale treatability test plan for the 200-BP-5 operable unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This document presents the treatability test plan for pilot-scale pump and treat testing at the 200-BP-5 Operable Unit. This treatability test plan has been prepared in response to an agreement between the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA), and the State of Washington Department of Ecology (Ecology), as documented in Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement, Ecology et al. 1989a) Change Control Form M-13-93-03 (Ecology et al. 1994) and a recent 200 NPL Agreement Change Control Form (Appendix A). The agreement also requires that, following completion of the activities described in thismore » test plan, a 200-BP-5 Operable Unit Interim Remedial Measure (IRM) Proposed Plan be developed for use in preparing an Interim Action Record of Decision (ROD). The IRM Proposed Plan will be supported by the results of this treatability test plan, as well as by other 200-BP-5 Operable Unit activities (e.g., development of a qualitative risk assessment). Once issued, the Interim Action ROD will specify the interim action(s) for groundwater contamination at the 200-BP-5 Operable Unit. The treatability test approach is to conduct a pilot-scale pump and treat test for each of the two contaminant plumes associated with the 200-BP-5 Operable Unit. Primary contaminants of concern are {sup 99}Tc and {sup 60}Co for underwater affected by past discharges to the 216-BY Cribs, and {sup 90}Sr, {sup 239/240}Pu, and Cs for groundwater affected by past discharges to the 216-B-5 Reverse Well. The purpose of the pilot-scale treatability testing presented in this testplan is to provide the data basis for preparing an IRM Proposed Plan. To achieve this objective, treatability testing must: Assess the performance of groundwater pumping with respect to the ability to extract a significant amount of the primary contaminant mass present in the two contaminant plumes.« less
Rodriguez, Brian D.; Sweetkind, Don; Burton, Bethany L.
2010-01-01
The U.S. Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) at their Nevada Site Office (NSO) are addressing groundwater contamination resulting from historical underground nuclear testing through the Environmental Management program and, in particular, the Underground Test Area (UGTA) project. From 1951 to 1992, 828 underground nuclear tests were conducted at the Nevada Test Site (NTS) northwest of Las Vegas (DOE UGTA, 2003). Most of these tests were conducted hundreds of feet above the groundwater table; however, more than 200 of the tests were near, or within, the water table. This underground testing was limited to specific areas of the NTS including Pahute Mesa, Rainier Mesa/Shoshone Mountain, Frenchman Flat, and Yucca Flat. Volcanic composite units make up much of the area within the Pahute Mesa Corrective Action Unit (CAU) at the NTS, Nevada. The extent of many of these volcanic composite units extends throughout and south of the primary areas of past underground testing at Pahute and Rainier Mesas. As situated, these units likely influence the rate and direction of groundwater flow and radionuclide transport. Currently, these units are poorly resolved in terms of their hydrologic properties introducing large uncertainties into current CAU-scale flow and transport models. In 2007, the U.S. Geological Survey (USGS), in cooperation with DOE and NNSA-NSO acquired three-dimensional (3-D) tensor magnetotelluric data at the NTS in Area 20 of Pahute Mesa CAU. A total of 20 magnetotelluric recording stations were established at about 600-m spacing on a 3-D array and were tied to ER20-6 well and other nearby well control (fig. 1). The purpose of this survey was to determine if closely spaced 3-D resistivity measurements can be used to characterize the distribution of shallow (600- to 1,500-m-depth range) devitrified rhyolite lava-flow aquifers (LFA) and zeolitic tuff confining units (TCU) in areas of limited drill hole control on Pahute Mesa within the Calico Hills zeolitic volcanic composite unit (VCU), an important hydrostratigraphic unit in Area 20. The resistivity response was evaluated and compared with existing well data and hydrogeologic unit tops from the current Pahute Mesa framework model. In 2008, the USGS processed and inverted the magnetotelluric data into a 3-D resistivity model. We interpreted nine depth slices and four west-east profile cross sections of the 3-D resistivity inversion model. This report documents the geologic interpretation of the 3-D resistivity model. Expectations are that spatial variations in the electrical properties of the Calico Hills zeolitic VCU can be detected and mapped with 3-D resistivity, and that these changes correlate to differences in rock permeability. With regard to LFA and TCU, electrical resistivity and permeability are typically related. Tuff confining units will typically have low electrical resistivity and low permeability, whereas LFA will have higher electrical resistivity and zones of higher fracture-related permeability. If expectations are shown to be correct, the method can be utilized by the UGTA scientists to refine the hydrostratigraphic unit (HSU) framework in an effort to more accurately predict radionuclide transport away from test areas on Pahute and Rainier Mesas.
NASA Technical Reports Server (NTRS)
Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.
1991-01-01
Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.
United States Nuclear Tests, July 1945 through September 1992, December 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy, Nevada Operations Office
2000-12-01
This document list chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Revision 15, dated December 2000.
Graphics Processor Units (GPUs)
NASA Technical Reports Server (NTRS)
Wyrwas, Edward J.
2017-01-01
This presentation will include information about Graphics Processor Units (GPUs) technology, NASA Electronic Parts and Packaging (NEPP) tasks, The test setup, test parameter considerations, lessons learned, collaborations, a roadmap, NEPP partners, results to date, and future plans.
Using the Teach-Back Method in Patient Education to Improve Patient Satisfaction.
Centrella-Nigro, Andrea M; Alexander, Catherine
2017-01-01
This quasi-experimental research study used two similar nursing units to test the effects of teach back on Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) scores. A pretest-posttest design tested 24 nurses' knowledge, attitudes, and beliefs about teach back. Education specialists provided a 1-hour teaching session on teach back to all nurses in the intervention unit. A significant improvement in knowledge scores in the pretest-posttest was found using paired t tests (p = .002). Qualitative analysis of nurses' comments demonstrated strong support for teach back in the post-test. The HCAHPS scores were not significantly improved in the intervention unit when compared with the control unit. More research needs to be conducted to determine the effectiveness of teach back on HCAHPS scores. J Contin Educ Nurs. 2017;48(1):47-52. Copyright 2017, SLACK Incorporated.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
Hollow cathode heater development for the Space Station plasma contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1993-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.
Segments from red blood cell units should not be used for quality testing.
Kurach, Jayme D R; Hansen, Adele L; Turner, Tracey R; Jenkins, Craig; Acker, Jason P
2014-02-01
Nondestructive testing of blood components could permit in-process quality control and reduce discards. Tubing segments, generated during red blood cell (RBC) component production, were tested to determine their suitability as a sample source for quality testing. Leukoreduced RBC components were produced from whole blood (WB) by two different methods: WB filtration and buffy coat (BC). Components and their corresponding segments were tested on Days 5 and 42 of hypothermic storage (HS) for spun hematocrit (Hct), hemoglobin (Hb) content, percentage hemolysis, hematologic indices, and adenosine triphosphate concentration to determine whether segment quality represents unit quality. Segment samples overestimated hemolysis on Days 5 and 42 of HS in both BC- and WB filtration-produced RBCs (p < 0.001 for all). Hct and Hb levels in the segments were also significantly different from the units at both time points for both production methods (p < 0.001 for all). Indeed, for all variables tested different results were obtained from segment and unit samples, and these differences were not consistent across production methods. The quality of samples from tubing segments is not representative of the quality of the corresponding RBC unit. Segments are not suitable surrogates with which to assess RBC quality. © 2013 American Association of Blood Banks.
Stephenson, Jennifer L.; Maluf, Katrina S.
2011-01-01
The paired motor unit analysis provides in vivo estimates of the magnitude of persistent inward currents (PIC) in human motoneurons by quantifying changes in the firing rate (ΔF) of an earlier recruited (reference) motor unit at the time of recruitment and derecruitment of a later recruited (test) motor unit. This study assessed the variability of ΔF estimates, and quantified the dependence of ΔF on the discharge characteristics of the motor units selected for analysis. ΔF was calculated for 158 pairs of motor units recorded from nine healthy individuals during repeated submaximal contractions of the tibialis anterior muscle. The mean (SD) ΔF was 3.7 (2.5) pps (range −4.2 to 8.9 pps). The median absolute difference in ΔF for the same motor unit pair across trials was 1.8 pps, and the minimal detectable change in ΔF required to exceed measurement error was 4.8 pps. ΔF was positively related to the amount of discharge rate modulation in the reference motor unit (r2=0.335; P<0.001), and inversely related to the rate of increase in discharge rate (r2=0.125; P<0.001). A quadratic function provided the best fit for relations between ΔF and the time between recruitment of the reference and test motor units (r2=0.229, P<0.001), the duration of test motor unit activity (r2=0.110, P<0.001), and the recruitment threshold of the test motor unit (r2=0.237, P<0.001). Physiological and methodological contributions to the variability in ΔF estimates of PIC magnitude are discussed, and selection criteria to reduce these sources of variability are suggested for the paired motor unit analysis. PMID:21459110
[Automated analyzer of enzyme immunoassay].
Osawa, S
1995-09-01
Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2010 CFR
2010-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...
40 CFR Table 37 to Subpart Uuu of... - Requirements for Performance Tests for Bypass Lines
Code of Federal Regulations, 2011 CFR
2011-07-01
... Bypass Lines 37 Table 37 to Subpart UUU of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION...: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 37 Table 37 to Subpart UUU of Part 63—Requirements for Performance Tests for Bypass Lines As stated in § 63...
Poirot, Jean-Louis; Gangneux, Jean-Pierre; Fischer, Alain; Malbernard, Mireille; Challier, Svetlana; Laudinet, Nicolas; Bergeron, Vance
2007-09-01
Invasive aspergillosis is one of the most lethal airborne dangers for immune-suppressed subjects. Providing patient protection from such airborne threats requires costly and high-maintenance facilities. We herein evaluate a new self-contained mobile unit as an alternative for creating a patient protective environment. Airborne contamination levels were monitored for different simulated scenarios and under actual clinical conditions. Functional tests were used to challenge the unit under adverse conditions, and a preliminary clinical study with patients and staff present was performed at 2 different French hospitals. Functional tests demonstrated that the unit can rapidly decontaminate air in the protected zone created by the unit and in the surrounding room. In addition, the protected zone is not sensitive to large disturbances that occur in the room. The clinical study included 4 patients with 150 accumulated days of testing. The protected zone created by the unit systematically provided an environment with undetectable airborne fungal levels (ie, <1 CFU/m(3)) regardless of the levels in the room or corridor (P < .01). These tests show that the unit can be used to create a mobile protective environment for immune-suppressed patients in a standard hospital setting.
Novel exposure units for at-home personalized testing of electromagnetic sensibility.
Huss, Anke; Murbach, Manuel; van Moorselaar, Imke; Kuster, Niels; van Strien, Rob; Kromhout, Hans; Vermeulen, Roel; Slottje, Pauline
2016-01-01
Previous experimental studies on electromagnetic hypersensitivity have been criticized regarding inflexibility of choice of exposure and of study locations. We developed and tested novel portable exposure units that can generate different output levels of various extremely low frequency magnetic fields (ELF-MF; 50 Hz field plus harmonics) and radiofrequency electromagnetic fields (RF-EMF). Testing was done with a group of healthy volunteers (n = 25 for 5 ELF-MF and n = 25 for 5 RF-EMF signals) to assess if units were indeed able to produce double-blind exposure conditions. Results substantiated that double-blind conditions were met; on average participants scored 50.6% of conditions correct on the ELF-MF, and 50.0% on the RF-EMF unit, which corresponds to guessing probability. No cues as to exposure conditions were reported. We aim to use these units in a future experiment with subjects who wish to test their personal hypothesis of being able to sense or experience when being exposed to EMF. The new units allow for a high degree of flexibility regarding choice of applied electromagnetic signal, output power level and location (at home or another environment of subjects' choosing). © 2015 Wiley Periodicals, Inc.
Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faakye, O.; Arena, L.; Griffiths, D.
2013-07-01
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H.; Higuchi, T.; Nishioki, N.
1997-01-01
A dual tunneling-unit scanning tunneling microscope (DTU STM) was developed for nm order length measurement with wide scan range. The crystalline lattice of highly oriented pyrolitic graphite (HOPG) was used as reference scale. A reference unit was set up on top of a test unit. The reference sample holder and the probe tip of test unit were attached to one single XY scanner on either surface, while the test sample holder was open. This enables simultaneous acquisition of wide images of HOPG and test sample. The length in test sample image was measured by counting the number of HOPG lattices.more » An inchworm actuator and an impact drive mechanism were introduced to roughly position probe tips. The XY scanner was designed to be elastic to eliminate image distortion. Some comparison experiments using two HOPG chips were carried out in air. The DTU STM is confirmed to be a stable and more powerful device for length measurement which has nanometer accuracy when covering a wide scan range up to several micrometers, and is capable of measuring comparatively large and heavy samples. {copyright} {ital 1997 American Vacuum Society.}« less
ChemCam Mast Unit Being Prepared for Laser Firing
2010-12-23
Researchers prepare for a test of the Chemistry and Camera ChemCam instrument that will fly on NASA Mars Science Laboratory mission; researchers are preparing the instrument mast unit for a laser firing test.
United States Nuclear Tests, July 1945 through September 1992, September 2015
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. This is Revision 16, dated September 2015.
Asphalt and Wood Shingling. Roofing Workbook and Tests.
ERIC Educational Resources Information Center
Brown, Arthur
This combination workbook and set of tests contains materials on asphalt and wood shingling that have been designed to be used by those studying to enter the roofing and waterproofing trade. It consists of seven instructional units and seven accompanying objective tests. Covered in the individual units are the following topics: shingling…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-10
... Whitney A Subsidiary of United Technologies Corporation Far Group and Experimental Test Group East... Technologies Corporation, FAR Group and Experimental Test Group, supplies/supports and operates as an extension... Test Group. The amended notice applicable to TA-W-75,152 is hereby issued as follows: ``All workers of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... test units'' from a supplier located in China.\\16\\ Share indicated that it had offered only three units... certain apparent discrepancies between the application, test report, and equipment certification as to the... description of the product: ``computer peripheral for preprocessing data.'' \\25\\ Similarly, the test report...
Astronaut Bruce McCandless tests astronaut maneuvering unit
1973-08-16
S72-30704 (1972) --- Astronaut Bruce McCandless II, backup pilot for Skylab 2, tests the balance and control of an astronaut maneuvering unit (AMU) test model at Martin Marietta Corporation's Denver division. The jet-powered backpack can fly for 30 minutes and can be worn over normal clothing or spacesuit. Photo credit: NASA
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2012 CFR
2012-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2014 CFR
2014-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
14 CFR 33.96 - Engine tests in auxiliary power unit (APU) mode.
Code of Federal Regulations, 2013 CFR
2013-01-01
... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Block Tests; Turbine Aircraft Engines § 33.96 Engine tests in auxiliary power unit (APU) mode. If the engine is designed with a propeller brake which...) Ground locking: A total of 45 hours with the propeller brake engaged in a manner which clearly...
Unit: Sticking Together, First Trial Materials, Inspection Set.
ERIC Educational Resources Information Center
Australian Science Education Project, Toorak, Victoria.
These materials, including teacher's guide, student test booklet and laboratory guide, student workbook, test booklet, and a booklet explaining the answers to the questions in the test booklet, are first trial versions of a unit that will form part of the Australian Science Education Project instructional materials for grades seven through ten.…
Initial closed operation of the CELSS Test Facility Engineering Development Unit
NASA Technical Reports Server (NTRS)
Kliss, M.; Blackwell, C.; Zografos, A.; Drews, M.; MacElroy, R.; McKenna, R.; Heyenga, A. G.
2003-01-01
As part of the NASA Advanced Life Support Flight Program, a Controlled Ecological Life Support System (CELSS) Test Facility Engineering Development Unit has been constructed and is undergoing initial operational testing at NASA Ames Research Center. The Engineering Development Unit (EDU) is a tightly closed, stringently controlled, ground-based testbed which provides a broad range of environmental conditions under which a variety of CELSS higher plant crops can be grown. Although the EDU was developed primarily to provide near-term engineering data and a realistic determination of the subsystem and system requirements necessary for the fabrication of a comparable flight unit, the EDU has also provided a means to evaluate plant crop productivity and physiology under controlled conditions. This paper describes the initial closed operational testing of the EDU, with emphasis on the hardware performance capabilities. Measured performance data during a 28-day closed operation period are compared with the specified functional requirements, and an example of inferring crop growth parameters from the test data is presented. Plans for future science and technology testing are also discussed. Published by Elsevier Science Ltd on behalf of COSPAR.
Assessing Situational Awareness in Task Force XXI.
1997-06-01
information dominance over the enemy and that units equipped with greater situational awareness will fight more successfully than units without the added capability. In an effort to test this hypothesis the Army conducted an Advanced Warfighter Experiment (AWE) which began at Ft. Hood, TX and culminated in a focused rotation at the National Training Center, Ft. Irwin, CA. Although many initiatives in the area of information dominance were tested in the AWE, the centerpiece of the program was a test case unit designated as Task Force Twenty-One (TF
CGBA, Pilot Kent Rominger films HHDTC units in Spacelab
1995-11-05
STS073-131-014 (20 October-5 November 1995) --- Astronaut Kent V. Rominger, STS-73 pilot, uses a camcorder to record progress in the Hand-Held Diffusion Test Cell (HHDTC) experiment. This test dealt with crystal growth by liquid-to-liquid diffusion. Four HHDTC units containing four test cells each produced protein crystals by diffusing one liquid to another. Rominger joined four other NASA astronauts and two guest researchers for 16 days of in-space United States Microgravity Laboratory 2 (USML-2) research aboard the Space Shuttle Columbia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-03-28
The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the last of three volumes and it is divided into the followingmore » sections: (1) Condition Assessment of Unit RL-10 Turbine-Generator; (2) Condition Assessment of Unit RL-10 and RL-11 Boiler Feed Pumps.« less
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin
2016-07-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.
Delivery of Colloid Micro-Newton Thrusters for the Space Technology 7 Mission
NASA Technical Reports Server (NTRS)
Ziemer, John K.; Randolph, Thomas M.; Franklin, Garth W.; Hruby, Vlad; Spence, Douglas; Demmons, Nathaniel; Roy, Thomas; Ehrbar, Eric; Zwahlen, Jurg; Martin, Roy;
2008-01-01
Two flight-qualified clusters of four Colloid Micro-Newton Thruster (CMNT) systems have been delivered to the Jet Propulsion Laboratory (JPL). The clusters will provide precise spacecraft control for the drag-free technology demonstration mission, Space Technology 7 (ST7). The ST7 mission is sponsored by the NASA New Millennium Program and will demonstrate precision formation flying technologies for future missions such as the Laser Interferometer Space Antenna (LISA) mission. The ST7 disturbance reduction system (DRS) will be on the ESA LISA Pathfinder spacecraft using the European gravitational reference sensor (GRS) as part of the ESA LISA Technology Package (LTP). Developed by Busek Co. Inc., with support from JPL in design and testing, the CMNT has been developed over the last six years into a flight-ready and flight-qualified microthruster system, the first of its kind. Recent flight-unit qualification tests have included vibration and thermal vacuum environmental testing, as well as performance verification and acceptance tests. All tests have been completed successfully prior to delivery to JPL. Delivery of the first flight unit occurred in February of 2008 with the second unit following in May of 2008. Since arrival at JPL, the units have successfully passed through mass distribution, magnetic, and EMI/EMC measurements and tests as part of the integration and test (I&T) activities including the integrated avionics unit (IAU). Flight software sequences have been tested and validated with the full flight DRS instrument successfully to the extent possible in ground testing, including full functional and 72 hour autonomous operations tests. Delivery of the cluster assemblies along with the IAU to ESA for integration into the LISA Pathfinder spacecraft is planned for the summer of 2008 with a planned launch and flight demonstration in late 2010.
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Mathers, Alex
2012-01-01
NASA Science Mission Directorate's In-Space Propulsion Technology Program is sponsoring the development of a 3.5 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn and Aerojet are developing a high fidelity high voltage Hall accelerator that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the high voltage Hall accelerator engineering development unit have been performed. Performance test results indicated that at 3.9 kW the thruster achieved a total thrust efficiency and specific impulse of 58%, and 2,700 sec, respectively. Thermal characterization tests indicated that the thruster component temperatures were within the prescribed material maximum operating temperature limits during full power thruster operation. Finally, thruster vibration tests indicated that the thruster survived the 3-axes qualification full-level random vibration test series. Pre and post-vibration test performance mappings indicated almost identical thruster performance. Finally, an update on the development progress of a power processing unit and a xenon feed system is provided.
Mobile HIV screening in Cape Town, South Africa: clinical impact, cost and cost-effectiveness.
Bassett, Ingrid V; Govindasamy, Darshini; Erlwanger, Alison S; Hyle, Emily P; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Paltiel, A David; Wood, Robin; Walensky, Rochelle P; Losina, Elena; Bekker, Linda-Gail; Freedberg, Kenneth A
2014-01-01
Mobile HIV screening may facilitate early HIV diagnosis. Our objective was to examine the cost-effectiveness of adding a mobile screening unit to current medical facility-based HIV testing in Cape Town, South Africa. We used the Cost Effectiveness of Preventing AIDS Complications International (CEPAC-I) computer simulation model to evaluate two HIV screening strategies in Cape Town: 1) medical facility-based testing (the current standard of care) and 2) addition of a mobile HIV-testing unit intervention in the same community. Baseline input parameters were derived from a Cape Town-based mobile unit that tested 18,870 individuals over 2 years: prevalence of previously undiagnosed HIV (6.6%), mean CD4 count at diagnosis (males 423/µL, females 516/µL), CD4 count-dependent linkage to care rates (males 31%-58%, females 49%-58%), mobile unit intervention cost (includes acquisition, operation and HIV test costs, $29.30 per negative result and $31.30 per positive result). We conducted extensive sensitivity analyses to evaluate input uncertainty. Model outcomes included site of HIV diagnosis, life expectancy, medical costs, and the incremental cost-effectiveness ratio (ICER) of the intervention compared to medical facility-based testing. We considered the intervention to be "very cost-effective" when the ICER was less than South Africa's annual per capita Gross Domestic Product (GDP) ($8,200 in 2012). We projected that, with medical facility-based testing, the discounted (undiscounted) HIV-infected population life expectancy was 132.2 (197.7) months; this increased to 140.7 (211.7) months with the addition of the mobile unit. The ICER for the mobile unit was $2,400/year of life saved (YLS). Results were most sensitive to the previously undiagnosed HIV prevalence, linkage to care rates, and frequency of HIV testing at medical facilities. The addition of mobile HIV screening to current testing programs can improve survival and be very cost-effective in South Africa and other resource-limited settings, and should be a priority.
The missing link? Testing a schema account of unitization.
Tibon, Roni; Greve, Andrea; Henson, Richard
2018-05-09
Unitization refers to the creation of a new unit from previously distinct items. The concept of unitization has been used to explain how novel pairings between items can be remembered without requiring recollection, by virtue of new, item-like representations that enable familiarity-based retrieval. We tested an alternative account of unitization - a schema account - which suggests that associations between items can be rapidly assimilated into a schema. We used a common operationalization of "unitization" as the difference between two unrelated words being linked by a definition, relative to two words being linked by a sentence, during an initial study phase. During the following relearning phase, a studied word was re-paired with a new word, either related or unrelated to the original associate from study. In a final test phase, memory for the relearned associations was tested. We hypothesized that, if unitized representations act like schemas, then we would observe some generalization to related words, such that memory would be better in the definition than sentence condition for related words, but not for unrelated words. Contrary to the schema hypothesis, evidence favored the null hypothesis of no difference between definition and sentence conditions for related words (Experiment 1), even when each cue was associated with multiple associates, indicating that the associations can be generalized (Experiment 2), or when the schematic information was explicitly re-activated during Relearning (Experiment 3). These results suggest that unitized associations do not generalize to accommodate new information, and therefore provide evidence against the schema account.
Comparison of the heat generation of light curing units.
Bagis, Bora; Bagis, Yildirim; Ertas, Ertan; Ustaomer, Seda
2008-02-01
The aim of this study was to evaluate the heat generation of three different types of light curing units. Temperature increases were recorded from a distance of 1 mm from a thermocouple to the tip of three different types of light curing units including one quartz-tungsten halogen (QTH), one plasma arc (PAC), and one light emitting diode (LED) unit. An experimental model was designed to fix the 1 mm distance between the tip of the light curing units and the thermocouple wire. Temperature changes were recorded in 10 second intervals up to 40 seconds. (10, 20, 30, and 40 seconds). Temperature measurements were repeated three times for every light curing unit after a one hour standby period. Statistical analysis of the results was performed using the analysis of variance (ANOVA) and the Bonferroni Test. The highest temperature rises (54.4+/-1.65 degrees C) occurred during activation of a PAC light curing unit for every test period (p<.05). The least temperature increase (11.8+/-1.3 degrees C) occurred with a LED curing unit for each tested period except for the measurement of the temperature rise using the QTH curing unit at the tenth second interval (p<.05). These results indicate the choice of light activation unit and curing time is important when polymerizing light activated resin based restorations to avoid any thermal damage to the pulp.
ERIC Educational Resources Information Center
Gavin, M. Katherine; Casa, Tutita M.; Firmender, Janine M.; Carroll, Susan R.
2013-01-01
The goal of Project M2 was to develop and field-test challenging geometry and measurement units for K-2 students. The units were developed using recommendations from gifted, mathematics, and early childhood education. This article reports on achievement results for students in Grade 1 at 12 diverse sites in four states using the Iowa Tests of…
The Tapwater Tour. The Hands-On Test Kit & Mini Curriculum for Exploring Drinking Water.
ERIC Educational Resources Information Center
LaMotte Co., Chestertown, MD.
The goal of this mini-curriculum is for students to discover what drinking water really is. Five units are designed to be presented as a lecture and to allow 30 to 40 students to perform every procedure, each testing their own tap water sample. Games are provided in each section to reinforce the concepts presented in each unit. Unit 1 introduces…
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Requirements for Performance Tests for Organic HAP Emissions From Catalytic Reforming Units 18 Table 18 to Subpart UUU of Part 63 Protection of... Sulfur Recovery Units Pt. 63, Subpt. UUU, Table 18 Table 18 to Subpart UUU of Part 63—Requirements for...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-04
... take a practical test after passing a knowledge test. For example, 14 CFR 61.39(a)(1) gives a person 24... operations. SFAR 100-2 also continues to allow FSDOs to accept expired airman written test reports for certain practical tests from U.S. personnel who are assigned outside the United States in support of U.S...
Disinfection of contaminated water by using solar irradiation.
Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad
2004-02-01
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.
[Is the use of plastic capillary tubes justified for blood gases analysis?].
Daurès, Marie-Françoise; Bozonnat, Marie-Cécile; Cristol, Jean-Paul
2011-01-01
Some clinical units, such as neonatal or maternity units, preferentially use capillary tubes when analysing blood gases. Using glass tubes is delicate and nurses must recollect blood when breaking. In order to eliminate this problem, we tested flexible, plastic capillary tubes in both the above mentionned units and in our biochemistry laboratory. Each unit, where glass tubes were habitually used, tested 200 flexible, plastic capillary tubes. In addition, the nursing staffed filled out a questionnaire concerned tube usage. Both units clearly preferred using the flexible tubes. In the laboratory, results for blood gas analyses were compared between rigid glass and flexible plastic capillary tubes for 112 patients. Concordance tests did not showed significant differences between the two tube types, except for hematocrit and total haemoglobin. A questionnaire was also presented to the lab technician, who confirmed the easier usability of plastic capillary tubes.
NASA Astrophysics Data System (ADS)
Slykhuis, David A.
This research project examined the efficacy of an online microcomputer-based laboratory based (MBL) physics unit. One hundred and fifty physics students from five high schools in North Carolina were divided into online and classroom groups. The classroom group completed the MBL unit in small groups with assistance from their teachers. The online groups completed the MBL unit in small groups using a website designed for this project for guidance. Pre- and post-unit content specific tests and surveys were given. Statistical analysis of the content tests showed significant development of conceptual understanding by the online group over the course of the unit. There was not a significant difference between the classroom and online group with relation to the amount of conceptual understanding developed. Correlations with post-test achievement showed that pre-test scores and math background were the most significant correlates with success. Computer related variables, such as computer comfort and online access, were only mildly correlated with the online group. Students' views about the nature of physics were not well developed prior to the unit and did not significantly change over the course of the unit. Examination of the students' physics conceptions after instruction revealed common alternative conceptions such as confusing position and velocity variables and incorrect interpretations of graphical features such as slope.
Accelerated testing of module-level power electronics for long-term reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Accelerated testing of module-level power electronics for long-term reliability
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar; ...
2016-11-10
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
Test Format and the Variation of Gender Achievement Gaps within the United States
ERIC Educational Resources Information Center
Reardon, Sean; Fahle, Erin; Kalogrides, Demetra; Podolsky, Anne; Zarate, Rosalia
2016-01-01
Prior research demonstrates the existence of gender achievement gaps and the variation in the magnitude of these gaps across states. This paper characterizes the extent to which the variation of gender achievement gaps on standardized tests across the United States can be explained by differing state accountability test formats. A comprehensive…
The purpose of this SOP is to describe the procedures for the periodic calibration and leak testing of Harvard particulate matter (PM) impactor units. This procedure applies directly to the calibration and leak testing of Harvard PM impactor units used during the Arizona NHEXAS ...
Software Measurement Guidebook. Version 02.00.02
1992-12-01
Compatibility Testing Process .............................. 9-5 Figure 9-3. Development Effort Planning Curve ................................. 9-7 Figure 10-1...requirements, design, code, and test and for analyzing this data. "* Proposal Manager. The person responsible for describing and supporting the estimated...designed, build/elease ranges, variances, and comparisons size growth; costs; completions; and content, units completing test , units with historical
Solar Heating Systems: Progress Checks & Tests Manual.
ERIC Educational Resources Information Center
Green, Joanne; And Others
This manual contains Progress Checks and Tests for use in a Solar Heating Systems curriculum (see note). It contains master copies of all Progress Checks and Unit Tests accompanying the curriculum, organized by unit. (The master copies are to be duplicated by each school so that adequate copies are available for student use in a self-paced student…
Testing to Characterize the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward; Schreiber, Jeffrey
2010-01-01
The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. Lockheed Martin designed and fabricated an engineering unit (EU), the ASRG EU, under contract to the Department of Energy. This unit is currently undergoing extended operation testing at the NASA Glenn Research Center to generate performance data and validate life and reliability predictions for the generator and the Stirling convertors. It has also undergone performance tests to characterize generator operation while varying control parameters and system inputs. This paper summarizes and explains test results in the context of designing operating strategies for the generator during a space mission and notes expected differences between the EU performance and future generators.
Verification of Wind Measurement with Mobile Laser Doppler System
DOT National Transportation Integrated Search
1977-09-01
The Lockheed Mobile Atmospheric Unit is a laser Doppler velocimeter system designed for the remote measurement of the three components of atmospheric wind. The unit was tested at the National Oceanic and Atmospheric Administration Table Mountain Test...
A Systems Approach to Costing in the Blood Bank
Delon, Gerald L.; Smalley, Harold E.
1969-01-01
A macroscopic approach to departmental cost finding is combined with a microscopic approach to the weighting of laboratory tests in a mathematical model which, when incorporated into a relative unit value format, yields unit costs for such tests under a wide variety of operational conditions. The task of updating such costs to reflect changing conditions can be facilitated by a computer program incorporating the capability of pricing the various tests to achieve any desired profit or loss or to break even. Among other potential uses of such a technique, the effects on unit cost per test caused by increasing or decreasing the number of technicians or the volume of tests can be systematically examined, and pricing can be updated each year as hospital costs change. PMID:5799486
The modern rotor aerodynamic limits survey: A report and data survey
NASA Technical Reports Server (NTRS)
Cross, J.; Brilla, J.; Kufeld, R.; Balough, D.
1993-01-01
The first phase of the Modern Technology Rotor Program, the Modern Rotor Aerodynamic Limits Survey, was a flight test conducted by the United States Army Aviation Engineering Flight Activity for NASA Ames Research Center. The test was performed using a United States Army UH-60A Black Hawk aircraft and the United States Air Force HH-60A Night Hawk instrumented main-rotor blade. The primary purpose of this test was to gather high-speed, steady-state, and maneuvering data suitable for correlation purposes with analytical prediction tools. All aspects of the data base, flight-test instrumentation, and test procedures are presented and analyzed. Because of the high volume of data, only select data points are presented. However, access to the entire data set is available upon request.
Symbolic Execution Enhanced System Testing
NASA Technical Reports Server (NTRS)
Davies, Misty D.; Pasareanu, Corina S.; Raman, Vishwanath
2012-01-01
We describe a testing technique that uses information computed by symbolic execution of a program unit to guide the generation of inputs to the system containing the unit, in such a way that the unit's, and hence the system's, coverage is increased. The symbolic execution computes unit constraints at run-time, along program paths obtained by system simulations. We use machine learning techniques treatment learning and function fitting to approximate the system input constraints that will lead to the satisfaction of the unit constraints. Execution of system input predictions either uncovers new code regions in the unit under analysis or provides information that can be used to improve the approximation. We have implemented the technique and we have demonstrated its effectiveness on several examples, including one from the aerospace domain.
Field Testing of Compartmentalization Methods for Multifamily Construction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ueno, K.; Lstiburek, J.
The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In thismore » project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).« less
Potable water recovery for spacecraft application by electrolytic pretreatment/air evaporation
NASA Technical Reports Server (NTRS)
Wells, G. W.
1975-01-01
A process for the recovery of potable water from urine using electrolytic pretreatment followed by distillation in a closed-cycle air evaporator has been developed and tested. Both the electrolytic pretreatment unit and the air evaporation unit are six-person, flight-concept prototype, automated units. Significantly extended wick lifetimes have been achieved in the air evaporation unit using electrolytically pretreated, as opposed to chemically pretreated, urine feed. Parametric test data are presented on product water quality, wick life, process power, maintenance requirements, and expendable requirements.
Testing of motor unit synchronization model for localized muscle fatigue.
Naik, Ganesh R; Kumar, Dinesh K; Yadav, Vivek; Wheeler, Katherine; Arjunan, Sridhar
2009-01-01
Spectral compression of surface electromyogram (sEMG) is associated with onset of localized muscle fatigue. The spectral compression has been explained based on motor unit synchronization theory. According to this theory, motor units are pseudo randomly excited during muscle contraction, and with the onset of muscle fatigue the recruitment pattern changes such that motor unit firings become more synchronized. While this is widely accepted, there is little experimental proof of this phenomenon. This paper has used source dependence measures developed in research related to independent component analysis (ICA) to test this theory.
High Power Alternator Test Unit (ATU) Electrical System Test
NASA Technical Reports Server (NTRS)
Birchenough, Arthur; Hervol, David
2007-01-01
The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.
Kirsch, L E; Nguyen, L; Moeckly, C S; Gerth, R
1997-01-01
Helium leak rate measurements were quantitatively correlated to the probability of microbial ingress for rubber-stoppered glass vials subjected to immersion challenge. Standard 10-mL tubing glass vials were modified by inserting micropipettes of various sizes (0.1 to 10 microns nominal diameter) into a side wall hole and securing them with epoxy. Butyl rubber closures and aluminum crimps were used to seal the vials. The test units were sealed in a helium-filled glove bag, then the absolute helium leak rates were determined. The test units were disassembled, filled with media, resealed, and autoclaved. The test units were thermally treated to eliminate airlocks within the micropipette lumen and establish a liquid path between microbial challenge media and the test units' contents. Microbial challenge was performed by immersing the test units in a 35 degrees C bath containing magnesium ion and 8 to 10 logs of viable P. diminuta and E. coli for 24 hours. The test units were then incubated at 35 degrees C for an additional 13 days. Microbial ingress was detected by turbidity and plating on blood agar. The elimination of airlocks was confirmed by the presence of magnesium ions in the vial contents by atomic absorption spectrometry. A total of 288 vials were subjected to microbial challenge testing. Those test units whose contents failed to show detectable magnesium ions were eliminated from further analysis. At large leak rates, the probability of microbial ingress approached 100% and at very low leak rates microbial ingress rates were 0%. A dramatic increase in microbial failure occurred in the leak rate region 10(-4.5) to 10(-3) std cc/sec, which roughly corresponded to leak diameters ranging from 0.4 to 2 microns. Below a leak rate of 10(-4.5) std cc/sec the microbial failure rate was < 10%. The critical leak rate in our studies, i.e. the value below which microbial ingress cannot occur because the leak is too small, was observed to be between 10(-5) and 10(-5.8) std cc/sec, which corresponds to an approximate leak diameter of 0.2-0.3 micron.
Do you have a well-designed organization?
Goold, Michael; Campbell, Andrew
2002-03-01
For most companies, organization design is neither a science nor an art; it's an oxymoron. Organizational structures evolve in fits and starts, shaped more by politics than by policies. Although most executives can sense when their organization designs are not working well, few take meaningful action, partly because they lack a practical framework to guide them. The authors of this article provide just such a framework; they present nine tests that can be used to either evaluate an existing organization design or create a new one. Four "fit" tests offer an initial screen: The market advantage test asks whether a design directs sufficient management attention to the company's sources of competitive advantage; the parenting advantage test determines whether the design gives enough attention to the corporate-level activities that provide real value to the company; the people test shows whether the design reflects the employees' strengths; and the feasibility test looks at constraints that may impede implementation. Five "good design" tests can help a company refine its prospective design. The specialist cultures test ensures that there's sufficient insulation for units that need to be different from the prevailing culture; the difficult-links test determines whether a design offers solutions for potentially problematic unit-to-unit links; the redundant-hierarchy test asks whether the design has too many parent levels; the accountability test looks at whether every unit has suitable controls; and the flexibility test ensures that the design lets the company adapt to change. Once a design is altered, the tests should be repeated. Organizational decisions are inevitably complex, and tweaking one part of the design may produce unanticipated consequences elsewhere.
Determination of hydraulic properties in the vicinity of a landfill near Antioch, Illinois
Kay, Robert T.; Earle, John D.
1990-01-01
A hydrogeologic investigation was conducted in and around a landfill near Antioch, Illinois, in December 1987. The investigation consisted, in part, of an aquifer test that was designed to determine the hydraulic connection between the hydrogeologic units in the area. The hydrogeologic units consist of a shallow, unconfined, sand and gravel aquifer of variable thickness that overlies an intermediate confining unit of variable thickness composed predominantly of till. Underlying the till is a deep, confined, sand and gravel aquifer that serves as the water supply for the village of Antioch. The aquifer test was conducted in the confined aquifer. Aquifer-test data were analyzed using the Hantush and Jacob method for a leaky confined aquifer with no storage in the confining unit. Calculated transmissivity of the confined aquifer ranged from 1.96x10^4 to 2.52x10^4 foot squared per day and storativity ranged from 2.10x10^-4 to 8.71x10^-4. Leakage through the confining unit ranged from 1.29x10^-4 to 7.84x10^-4 foot per day per foot, and hydraulic conductivity of the confining unit ranged from 3.22x10^-3 to 1.96x10^-2 foot per day. The Hantush method for analysis of a leaky confined aquifer with storage in the confining unit also was used to estimate aquifer and confining-unit properties. Transmissivity and storativity values calculated using the Hantush method are in good agreement with the values calculated from the Hantush and Jacob method. Properties of the confining unit were estimated using the ratio method of Neuman and Witherspoon. The estimated diffusivity of the confining unit ranged from 50.36 to 68.13 feet squared per day, A value for the vertical hydraulic conductivity of the confining unit calculated from data obtained using both the Hantush and the Neuman and Witherspoon methods was within the range of values calculated by the Hantush and Jacob method. The aquifer-test data clearly showed that the confining unit is hydraulically connected to the confined aquifer. The aquifer-test data also indicated that the unconfined aquifer becomes hydraulically connected to the deep sand and gravel aquifer within 24 hours after the start of pumping in the confined aquifer.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Inorganic HAP Emissions From Catalytic Reforming Units 25 Table 25 to Subpart UUU of Part 63 Protection of... Units Pt. 63, Subpt. UUU, Table 25 Table 25 to Subpart UUU of Part 63—Requirements for Performance Tests... Procedure) in appendix A to subpart UUU; or EPA Method 5050 combined either with EPA Method 9056, or with...
Estimating Missing Unit Process Data in Life Cycle Assessment Using a Similarity-Based Approach.
Hou, Ping; Cai, Jiarui; Qu, Shen; Xu, Ming
2018-05-01
In life cycle assessment (LCA), collecting unit process data from the empirical sources (i.e., meter readings, operation logs/journals) is often costly and time-consuming. We propose a new computational approach to estimate missing unit process data solely relying on limited known data based on a similarity-based link prediction method. The intuition is that similar processes in a unit process network tend to have similar material/energy inputs and waste/emission outputs. We use the ecoinvent 3.1 unit process data sets to test our method in four steps: (1) dividing the data sets into a training set and a test set; (2) randomly removing certain numbers of data in the test set indicated as missing; (3) using similarity-weighted means of various numbers of most similar processes in the training set to estimate the missing data in the test set; and (4) comparing estimated data with the original values to determine the performance of the estimation. The results show that missing data can be accurately estimated when less than 5% data are missing in one process. The estimation performance decreases as the percentage of missing data increases. This study provides a new approach to compile unit process data and demonstrates a promising potential of using computational approaches for LCA data compilation.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
As one in a series of test item collections developed by the Assessment and Evaluation Unit of the Directorate of Studies, items of value from past tests are made available to teachers for the construction of unit tests, term examinations or as a basis for class discussion. Each collection was reviewed for content validity and reliability. The…
Test Program for Assessing Vulnerability of Industrial Equipment to Nuclear Air Blast.
1983-10-01
PROJECT. TASK 4Scientific Servic, Inc. AREA & WORK UNIT NUMBERS 517 East Bayshore Work Unit 1124F Redwood City, CA 94063___ __________ 11. CONTROLLING ...vulnerability, but perhaps less expensive, to be selected and substituted, with an eye to cost control . 5. MODELING AND SCALING CONSIDERATIONS Reiterating...behavior and properties of the test items and Interfaces that control behavior (e4g., test objects/flow field, test objects/interfacing surface of
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2014-07-08
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-01-27
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Vodnick, David James; Dwivedi, Arpit; Keranen, Lucas Paul; Okerlund, Michael David; Schmitz, Roger William; Warren, Oden Lee; Young, Christopher David
2015-02-24
An automated testing system includes systems and methods to facilitate inline production testing of samples at a micro (multiple microns) or less scale with a mechanical testing instrument. In an example, the system includes a probe changing assembly for coupling and decoupling a probe of the instrument. The probe changing assembly includes a probe change unit configured to grasp one of a plurality of probes in a probe magazine and couple one of the probes with an instrument probe receptacle. An actuator is coupled with the probe change unit, and the actuator is configured to move and align the probe change unit with the probe magazine and the instrument probe receptacle. In another example, the automated testing system includes a multiple degree of freedom stage for aligning a sample testing location with the instrument. The stage includes a sample stage and a stage actuator assembly including translational and rotational actuators.
Ground Operations Aerospace Language (GOAL). Volume 3: Data bank
NASA Technical Reports Server (NTRS)
1973-01-01
The GOAL (Ground Operations Aerospace Language) test programming language was developed for use in ground checkout operations in a space vehicle launch environment. To insure compatibility with a maximum number of applications, a systematic and error-free method of referencing command/response (analog and digital) hardware measurements is a principle feature of the language. Central to the concept of requiring the test language to be independent of launch complex equipment and terminology is that of addressing measurements via symbolic names that have meaning directly in the hardware units being tested. To form the link from test program through test system interfaces to the units being tested the concept of a data bank has been introduced. The data bank is actually a large cross-reference table that provides pertinent hardware data such as interface unit addresses, data bus routings, or any other system values required to locate and access measurements.
Tests of an experimental slash ignition unit
James L. Murphy; Harry E. Schimke
1965-01-01
A prototype ignition package containing an incendiary powder and designed for slash and brush burning jobs showed some promise, but the unit tested was not superior to such conventional devices as fusees, diesel backpack type flamethrowers, Very pistols, and drip torches.
ERIC Educational Resources Information Center
Cowan, Earl; And Others
The curriculum guide for welding instruction contains 16 units presented in six sections. Each unit is divided into the following areas, each of which is color coded: terminal objectives, specific objectives, suggested activities, and instructional materials; information sheet; transparency masters; assignment sheet; test; and test answers. The…
Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C
2005-08-15
Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
46 CFR 131.585 - Periodic servicing of hydrostatic-release units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Periodic servicing of hydrostatic-release units. 131.585... OPERATIONS Tests, Drills, and Inspections § 131.585 Periodic servicing of hydrostatic-release units. (a) Except a disposable hydrostatic-release unit with an expiration date, each hydrostatic-release unit must...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
49 CFR 234.217 - Flashing light units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Flashing light units. 234.217 Section 234.217..., Inspection, and Testing Maintenance Standards § 234.217 Flashing light units. (a) Each flashing light unit.... (b) Each flashing light unit shall be maintained to prevent dust and moisture from entering the...
Garcia, C. Amanda; Halford, Keith J.; Laczniak, Randell J.
2010-01-01
Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.
Development Studies for a Novel Wet Oxidation Process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delphi Research
1999-09-30
DETOX is a catalyzed wet oxidation process that destroys organic materials in an acidic water solution of iron at 373 to 473 K. The solution can be used repeatedly to destroy great amounts of organic materials. Since the process is conducted in a contained vessel, air emissions from the process can be well controlled. The solution is also capable of dissolving and concentrating many heavy and radioactive metals for eventual stabilization and disposal. The Phase III effort for this project is fabrication, assembly, and installation of the DETOX demonstration unit, preparation of documentation and training to meet site requirements formore » operation, followed by system run-in and shakedown testing of the unit prior to demonstration testing. The Title III design was completed and the unit was fabricated according to standards set forth by OSHA, EPA, the American Petroleum Institute (i.e., chemical and petroleum industry standards), and the ASME B-313 Piping Code requirements as agreed to in preliminary design meetings with primary stakeholders. The unit was assembled in three modules and two trailers and then shipped to the TNX facility at the Savannah River Site in September and october of 1996. On-going site integration tasks were address while delays in installation arose due to funding sources and costs. In March of 1997, Delphi was authorized to proceed with the installation of the unit, making electrical and mechanical connections necessary to operate the unit. All installation tasks were completed in August of 1997. Results of an Operational Readiness Review conducted in August 1997 verified that Delphi's procedures and documentation met the necessary requirements to operate the unit at SRS. Completion of the final checklist of WSRC requirements was then addressed including the Owner's Independent Inspection Report, verifying all components of the unit met B-31.3 standards. Final hydraulic and pneumatic tests were completed in November to satisfy the B-31.3 requirement. During the month of December, the control system and heating and cooling systems were then prepared to initiate system startup and conduct the run-in tests. Shakedown tests were combined with the Phase IV tasks due to DOE funding constraints, i.e., tests formerly planned to be conducted with oil and solid materials were deferred to Phase IV and combined with similar testing. Once run-in testing has been completed, the primary objectives of Phase III will have been achieved and the project will be ready to proceed to demonstration testing (Phase IV).« less
Integrity verification testing of the ADI International Inc. Pilot Test Unit No. 2002-09 with MEDIA G2® arsenic adsorption media filter system was conducted at the Hilltown Township Water and Sewer Authority (HTWSA) Well Station No. 1 in Sellersville, Pennsylvania from October 8...
United States nuclear tests, July 1945 through September 1992
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-12-01
This document lists chronologically and alphabetically by name all nuclear tests and simultaneous detonations conducted by the United States from July 1945 through September 1992. Several tests conducted during Operation Dominic involved missile launches from Johnston Atoll. Several of these missile launches were aborted, resulting in the destruction of the missile and nuclear device either on the pad or in the air.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bechtel Nevada; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office
2005-05-01
This Streamlined Approach for Environmental Restoration Plan provides the details for the closure of Corrective Action Unit (CAU) 489: WWII UXO Sites, Tonopah Test Range. CAU 489 is located at the Tonopah Test Range and is currently listed in Appendix III of the Federal Facility Agreement and Consent Order of 1996.
Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseus
Carpentier, Alain; Duchateau, Jacques; Hainaut, Karl
2001-01-01
In 67 single motor units, the mechanical properties, the recruitment and derecruitment thresholds, and the discharge rates were recorded concurrently in the first dorsal interosseus (FDI) of human subjects during intermittent fatiguing contractions. The task consisted of isometric ramp-and-hold contractions performed at 50% of the maximal voluntary contraction (MVC). The purpose of this study was to examine the influence of fatigue on the behaviour of motor units with a wide range of activation thresholds. For low-threshold (< 25% MVC) motor units, the mean twitch force increased with fatigue and the recruitment threshold either did not change or increased. In contrast, the twitch force and the activation threshold decreased for the high-threshold (> 25% MVC) units. The observation that in low-threshold motor units a quick stretch of the muscle at the end of the test reset the unit force and recruitment threshold to the prefatigue value suggests a significant role for fatigue-related changes in muscle stiffness but not twitch potentiation or motor unit synchronization. Although the central drive intensified during the fatigue test, as indicated by an increase in surface electromyogram (EMG), the discharge rate of the motor units during the hold phase of each contraction decreased progressively over the course of the task for motor units that were recruited at the beginning of the test, especially the low-threshold units. In contrast, the discharge rates of newly activated units first increased and then decreased. Such divergent behaviour of low- and high-threshold motor units could not be individually controlled by the central drive to the motoneurone pool. Rather, the different behaviours must be the consequence of variable contributions from motoneurone adaptation and afferent feedback from the muscle during the fatiguing contraction. PMID:11483719
The 1991 LLWAS anemometer test program
NASA Astrophysics Data System (ADS)
Phillips, Charles O.; Burnham, David; Jacobs, Leo; Hazen, David
1992-09-01
Performance tests of anemometers under icing and snow conditions were conducted during 1990-1991 on the test field at Rochester, MN and in icing chambers and wind tunnels at Sterling, VA. These tests were done for the FAA Low Level Windshear Alert System (LLWAS) program to test sensors for the next phase of LLWAS. Sensors from ten manufacturers were accepted into the test program from the respondents to the Commerce Business Daily. These sensors were required first to pass an icing chamber test in order to be field tested. The field tests lasted from Nov. 1990 to Jul. 1991. Afterwards, all sensors were sent to Sterling, VA for wind tunnel tests in September 1991. All units from the eight manufacturers that passed the icing chamber test were in the field test. A propeller/vane sensor that failed the icing chamber test was put in the field as a reference. All the units that passed were not affected by icing during the field test although a mechanical unit was affected by snow during one event. The propeller/vane was affected by icing during one event. Wind tunnel tests were done to check starting thresholds and calibration anomalies found in the field. It was concluded that there is no one winning technology that could be found from the tests.
NASA Technical Reports Server (NTRS)
Wilson, D. J.; Krause, M. C.; Craven, C. E.; Edwards, B. B.; Coffey, E. W.; Huang, C. C.; Jetton, J. L.; Morrison, L. K.
1974-01-01
A program plan for system evaluation of the two-dimensional Scanning Laser Doppler System (SLDS) is presented. In order to meet system evaluation and optimization objectives the following tests were conducted: (1) noise tests; (2) wind tests; (3) blower flowfield tests; (4) single unit (1-D) flyby tests; and (5) dual unit (2-D) flyby tests. Test results are reported. The final phase of the program included logistics preparation, equipment interface checkouts, and data processing. It is concluded that the SLDS is capable of accurately tracking aircraft wake vortices from small or large aircraft, and in any type of weather.
Turbine Powered Simulator Calibration and Testing for Hybrid Wing Body Powered Airframe Integration
NASA Technical Reports Server (NTRS)
Shea, Patrick R.; Flamm, Jeffrey D.; Long, Kurtis R.; James, Kevin D.; Tompkins, Daniel M.; Beyar, Michael D.
2016-01-01
Propulsion airframe integration testing on a 5.75% scale hybrid wing body model us- ing turbine powered simulators was completed at the National Full-Scale Aerodynamics Complex 40- by 80-foot test section. Four rear control surface con gurations including a no control surface de ection con guration were tested with the turbine powered simulator units to investigate how the jet exhaust in uenced the control surface performance as re- lated to the resultant forces and moments on the model. Compared to ow-through nacelle testing on the same hybrid wing body model, the control surface e ectiveness was found to increase with the turbine powered simulator units operating. This was true for pitching moment, lift, and drag although pitching moment was the parameter of greatest interest for this project. With the turbine powered simulator units operating, the model pitching moment was seen to increase when compared to the ow-through nacelle con guration indicating that the center elevon and vertical tail control authority increased with the jet exhaust from the turbine powered simulator units.
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baxter, V. D.; Rice, K.; Murphy, R.
Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted totalmore » annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test experience, CM developed a 2nd generation (or beta) prototype in 2012. Field test verification units were fabricated and installed at the ZEBRAlliance site in Oak Ridge in May 2012 and at several sites near CM headquarters in Oklahoma. Field testing of the units continued through February 2013. Annual performance analyses of the beta unit (prototype 2) with vertical well ground heat exchangers (GHX) in 5 U.S. locations predict annual energy savings of 57% to 61%, averaging 59% relative to the minimum efficiency suite and 38% to 56%, averaging 46% relative to the SOA GSHPwDS. Based on the steady-state performance demonstrated by the test units it was projected that the 2nd generation units would achieve ~58% energy savings relative to the minimum efficiency suite at the Zebra Alliance site with horizontal GHX. A new product based on the beta unit design was announced by CM in 2012 – the Trilogy 40® Q-mode™ (http://cmdealernet.com/trilogy_40.html). The unit was formally introduced in a March 2012 press release (see Appendix A) and was available for order beginning in December 2012.« less
Qualification test unit slide stainer (Beckman P/N 673753)
NASA Technical Reports Server (NTRS)
Bernier, P. S.
1972-01-01
Specifications for a slide stainer unit for the Skylab program are presented. The qualification test slide stainer was designed to be a self-contained system capable of performing an eight-step Gram stain of microorganisms and a Wright's stain of blood smears.
Basic Facialist. Teacher Edition. Cosmetology Series.
ERIC Educational Resources Information Center
Rogers, Jeanette A.
This Oklahoma curriculum guide contains six units. Each instructional unit includes some or all of these basic components: performance objectives; suggested activities for the teacher; pretest; handouts; information sheets; transparency masters; assignment sheets; job sheets; practical tests; written tests; and answers to pretest, assignment…
Code of Federal Regulations, 2011 CFR
2011-07-01
... distributed across the specific number of units. The nonrecurring research, development, test, and evaluation... significant military equipment on the United States Munitions List having a nonrecurring research, development... for research, development, test, and evaluation shall be based on DoD obligations recorded to the date...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilpinen, P.; Kallio, S.; Hupa, M.
1999-07-01
This paper describes work-in-progress aimed at developing an emission model for circulating fluidized bed combustors using detailed homogeneous and heterogeneous chemical kinetics. The main emphasis is on nitrogen oxides (NO{sub x}, N{sub 2}O) but also unburned gases (CO, C{sub x}H{sub y}) and sulfur dioxide (SO{sub 2}) will be investigated in the long run. The hydrodynamics is described by a 1.5-dimensional model where the riser is divided into three regions: a dense bubbling bed at the bottom, a vigorously mixed splash zone, and a transport zone. The two latter zones are horizontally split into a core region and an annular region.more » The solids circulation rate is calculated from the known solids inventory and the pressure and mass balances over the entire circulation loop. The solids are divided into classes according to size and type or particle. The model assumes instantaneous fuel devolatilization at the bottom and an even distribution of volatiles in the suspension phase of the dense bed. For addition of secondary air, a complete penetration and an instantaneous mixing with the combustor gases in the core region is assumed. The temperature distribution is assumed to be known, and no energy balance is solved. A comprehensive kinetic scheme of about 300 elementary gas-phase reactions is used to describe the homogeneous oxidation of the volatiles including both hydrocarbon and volatile-nitrogen components (NH{sub 3}, HCN). Heterogeneous char combustion to CO and CO{sub 2}, and char-nitrogen conversion to NO, N{sub 2}O, and N{sub 2} are described by a single particle model that includes 15 reaction steps given in the form of 6 net reaction paths. In the paper, the model is briefly described. A special emphasis is put on the evaluation of chemistry submodels. Modeling results on nitrogen oxides' formation are compared with measured concentration profiles in a 12 MW CFBC riser from literature. The importance of accurate chemistry description on predictions is illustrated by comparing modeling results using detailed kinetics to those obtained when hydrocarbon and volatile-nitrogen oxidation are described with empirical, global kinetic rate expressions from literature. Submodels that need further improvements are discussed.« less
Test Results from a Direct Drive Gas Reactor Simulator Coupled to a Brayton Power Conversion Unit
NASA Technical Reports Server (NTRS)
Hervol, David S.; Briggs, Maxwell H.; Owen, Albert K.; Bragg-Sitton, Shannon M.; Godfroy, Thomas J.
2010-01-01
Component level testing of power conversion units proposed for use in fission surface power systems has typically been done using relatively simple electric heaters for thermal input. These heaters do not adequately represent the geometry or response of proposed reactors. As testing of fission surface power systems transitions from the component level to the system level it becomes necessary to more accurately replicate these reactors using reactor simulators. The Direct Drive Gas-Brayton Power Conversion Unit test activity at the NASA Glenn Research Center integrates a reactor simulator with an existing Brayton test rig. The response of the reactor simulator to a change in Brayton shaft speed is shown as well as the response of the Brayton to an insertion of reactivity, corresponding to a drum reconfiguration. The lessons learned from these tests can be used to improve the design of future reactor simulators which can be used in system level fission surface power tests.
Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul
2016-01-01
In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832
Simon, Uwe K.; Gesslbauer, Lisa; Fink, Andreas
2016-01-01
Epilepsy is not a regular topic in many countries’ schools. Thus many people harbor misconceptions about people suffering from this disease. It was our aim to a) examine what grade ten students know and believe about epilepsy, and b) to develop and test a teaching unit to improve their knowledge and attitude. The test group comprised eight grade ten classes from six different Austrian high schools (54 girls and 51 boys aged 14–17), the control group (no intervention) five grade ten classes from the same schools (26 girls and 37 boys aged 14–17). The teaching unit consisted of three 45-min lessons using different methods and material. Changes in knowledge about and attitude towards epilepsy as a result of the intervention were psychometrically assessed in a pre-test intervention post-test design (along with a follow-up assessment two months after the intervention) by means of a questionnaire capturing different facets of epilepsy-related knowledge and attitude. Across all knowledge/attitude domains, students of the test group had a significantly improved knowledge about and a more positive attitude towards epilepsy and people suffering from it after the teaching unit. However, starting levels were different between the five knowledge/attitude domains tested. Medical background knowledge was lowest and consequently associated with the highest increase after the intervention. This study shows that epilepsy-related knowledge of many grade ten high school students is fragmentary and that some harbor beliefs and attitudes which require improvement. Our comprehensive but concise teaching unit significantly increased knowledge about epilepsy and positively influenced attitude towards individuals with epilepsy. Thus we recommend implementing this unit into regular school curricula. PMID:26919557
Daniels, Alan H; Paller, David J; Koruprolu, Sarath; Palumbo, Mark A; Crisco, Joseph J
2013-01-01
Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions.
Daniels, Alan H.; Paller, David J.; Koruprolu, Sarath; Palumbo, Mark A.; Crisco, Joseph J.
2013-01-01
Background Biomechanical investigations of spinal motion preserving implants help in the understanding of their in vivo behavior. In this study, we hypothesized that the lumbar spine with implanted total spinal segment replacement (TSSR) would exhibit decreased dynamic stiffness and more rapid energy absorption compared to native functional spinal units under simulated physiologic motion when tested with the pendulum system. Methods Five unembalmed, frozen human lumbar functional spinal units were tested on the pendulum system with axial compressive loads of 181 N, 282 N, 385 N, and 488 N before and after Flexuspine total spinal segment replacement implantation. Testing in flexion, extension, and lateral bending began by rotating the pendulum to 5°; resulting in unconstrained oscillatory motion. The number of rotations to equilibrium was recorded and bending stiffness (N-m/°) was calculated and compared for each testing mode. Results The total spinal segment replacement reached equilibrium with significantly fewer cycles to equilibrium compared to the intact functional spinal unit at all loads in flexion (p<0.011), and at loads of 385 N and 488 N in lateral bending (p<0.020). Mean bending stiffness in flexion, extension, and lateral bending increased with increasing load for both the intact functional spinal unit and total spinal segment replacement constructs (p<0.001), with no significant differences in stiffness between the intact functional spinal unit and total spinal segment replacement in any of the test modes (p>0.18). Conclusions Lumbar functional spinal units with implanted total spinal segment replacement were found to have similar dynamic bending stiffness, but absorbed energy at a more rapid rate than intact functional spinal units during cyclic loading with an unconstrained pendulum system. Although the effects on clinical performance of motion preserving devices is not fully known, these results provide further insight into the biomechanical behavior of this device under approximated physiologic loading conditions. PMID:23451222
Saturn V Instrument Unit Being Checked At MSFC
NASA Technical Reports Server (NTRS)
1967-01-01
A technician checks the systems of the Saturn V instrument unit in a test facility in Huntsville. This instrument unit was flown aboard Apollo 4 on November 7, 1967, which was the first test flight of the Saturn V. The towering 363-foot Saturn V was a multi-stage, multi-engine launch vehicle standing taller than the Statue of Liberty. Altogether, the Saturn V engines produced as much power as 85 Hoover Dams.
Absolute pressure transducers for space shuttle and orbiter propulsion and control systems
NASA Technical Reports Server (NTRS)
Bolta, J. J.
1974-01-01
A preliminary design was completed, reviewing of such subjects as: the trade studies for media isolation and one sensor vs. two sensors for two bridges; compensation resistors; unit design; hydrogen embrittlement; sealing techniques and test station design. A design substantiation phase was finished, consisting of testing of a prototype unit and fabrication technique studies. A cryogenic test station was implemented and prototype sensor cells were fabricated, sensors assembled, and cryogenic tests performed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sivakumar Babu, G.L., E-mail: gls@civil.iisc.ernet.in; Lakshmikanthan, P., E-mail: lakshmikanthancp@gmail.com; Santhosh, L.G., E-mail: lgsanthu2006@gmail.com
Highlights: • Shear strength properties of mechanically biologically treated municipal solid waste. • Effect of unit weight and particle size on the shear strength of waste. • Effect of particle size on the strength properties. • Stiffness ratio and the strength ratio of MSW. - Abstract: Strength and stiffness properties of municipal solid waste (MSW) are important in landfill design. This paper presents the results of comprehensive testing of shear strength properties of mechanically biologically treated municipal solid waste (MBT-MSW) in laboratory. Changes in shear strength of MSW as a function of unit weight and particle size were investigated bymore » performing laboratory studies on the MSW collected from Mavallipura landfill site in Bangalore. Direct shear tests, small scale and large scale consolidated undrained and drained triaxial tests were conducted on reconstituted compost reject MSW samples. The triaxial test results showed that the MSW samples exhibited a strain-hardening behaviour and the strength of MSW increased with increase in unit weight. Consolidated drained tests showed that the mobilized shear strength of the MSW increased by 40% for a unit weight increase from 7.3 kN/m{sup 3} to 10.3 kN/m{sup 3} at 20% strain levels. The mobilized cohesion and friction angle ranged from 5 to 9 kPa and 8° to 33° corresponding to a strain level of 20%. The consolidated undrained tests exhibited reduced friction angle values compared to the consolidated drained tests. The friction angle increased with increase in the unit weight from 8° to 55° in the consolidated undrained tests. Minor variations were found in the cohesion values. Relationships for strength and stiffness of MSW in terms of strength and stiffness ratios are developed and discussed. The stiffness ratio and the strength ratio of MSW were found to be 10 and 0.43.« less
NASA Astrophysics Data System (ADS)
Rustam, Shahrulfadly; Kassim, Mohar
2018-05-01
The aim of this study is to develop physical fitness index (PFI) for physical fitness among Army Reserve Officer Training Unit Cadet Malaysia. This study use 30 meter speed run as a physical fitness test battery to develop physical fitness index (PFI) and to evaluate the subject fitness speed. 212 male respondent (N=212) was selected in this study including Army Reserve Officer Training Unit Cadet of National Defence University of Malaysia. 30 meter sprint was used as a instrument for this study. The methodology will be adopted for this study is quantitative research in the form of a quasi-experiment. Quasi-experimental methods is used to measure and evaluate the level of physical fitness and develop Physical Fitness Index especially in speed. The design of this study is quasi-experimental study design with pre-test and post-test. The study design is quasi-experimental research design in which the data is obtained through the practical test in the field. The data were analysed by using the SPSS software version 20 to calculate the mean, standard deviation and t-test for develop physical fitness index (PFI) and to evaluate the fitness speed level for Army Reserve Officers Training Unit Cadet Malaysia. The findings showed mean and standard deviation for develope physical fitness index is (M=4.84) and (SD=0.48). The t-test for evaluate fitness level in speed for pre-test and post-test is significantly difference (p ≤ 0.05). The implication at this study is that the develope of standard physical fitness index is able to identify the level of physical fitness among Army Reserve Officer Training Unit Cadet Malaysia.
MTR WING, TRA604. ONE OF THE LABORATORY UNITS ALONG THE ...
MTR WING, TRA-604. ONE OF THE LABORATORY UNITS ALONG THE SOUTH SIDE WALL. NOTE SINK, CABINET, TABLE, AND HOOD UNITS. DUCT ABOVE RECEIVES CONTAMINATED AIR AND SENDS IT TO FAN HOUSE AND STACK. NOTE PARTITION WALL BEHIND WORK UNITS. THE HEALTH PHYSICS LAB WAS SIMILARLY EQUIPPED. WINDOW AT LEFT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 4225. Unknown Photographer, 2/13/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M
2013-10-01
The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.
Design and performance of the VLT 8-m coating unit
NASA Astrophysics Data System (ADS)
Schneermann, Michael W.; Groessl, M.; Nienaber, U.; Ettlinger, E.; Spiteri, J. A.; Clow, H.
1997-03-01
The 8 m coating unit for the VLT mirrors is designed for the deposition of high reflective, homogeneous aluminum coatings. For the process of the film deposition the sputter technology is utilized. The design of the following major subsystems is completed: the vacuum vessel and the vacuum generation system, the thin film deposition equipment and the glow discharge cleaning device, the substrate support and rotation system as well as the supporting framework and the auxiliary equipment. Manufacturing of the coating unit has started. The pre- assembly and testing activities, which will take place prior to the shipment to the site, are defined. This paper describes the design features and the major performance requirements of the 8 m coating unit. The performance of the sputter source design has been verified in a qualification test. The deposition rate, the film thickness and reflectance, as well as the film purity have been measured. The test set-up and the results of the qualification tests of the selected magnetron type are presented and discussed.
Zhang, Quanguo; Zhang, Zhiping; Wang, Yi; Lee, Duu-Jong; Li, Gang; Zhou, Xuehua; Jiang, Danping; Xu, Bo; Lu, Chaoyang; Li, Yameng; Ge, Xumeng
2018-04-01
Pilot tests of sequential dark and photo fermentation H 2 production were for the first time conducted in a 11 m 3 reactor (3 m 3 for dark and 8 m 3 for photo compartments). A combined solar and light-emitting diode illumination system and a thermal controlling system was installed and tested. With dark fermentation unit maintained at pH 4.5 and 35 °C and photo fermentation unit at pH 7.0 and 30 °C, the overall biogas production rate using hydrolyzed corn stover as substrate reached 87.8 ± 3.8 m 3 /d with 68% H 2 content, contributed by dark unit at 7.5 m 3 -H 2 /m 3 -d and by photo unit at 4.7 m 3 /m 3 -d. Large variation was noted for H 2 production rate in different compartments of the tested units, revealing the adverse effects of poor mixing, washout, and other inhomogeneity associated with large reactor operations. Copyright © 2018 Elsevier Ltd. All rights reserved.
Use of the Blind Learning Aptitude Test with Children in England and Wales and the United States.
ERIC Educational Resources Information Center
Mason, H. L.
1991-01-01
An 18-month study of the use of the Blind Learning Aptitude Test at schools for visually impaired children in England and Wales found the test to be culturally fair and appropriate for use with children for whom English is a second language. Scores are compared with standardization data for visually impaired children in the United States.…
ERIC Educational Resources Information Center
Liu, Xiufeng; Zhang, Baohui; Liang, Ling L.; Fulmer, Gavin; Kim, Beaumie; Yuan, Haiquan
2009-01-01
Alignment between content standards and standardized tests is a significant issue to society, science pedagogy, and test validation. To better understand the issues related to alignment, this study compares the alignment in physics among three education systems: Jiangsu (China), New York State (United States), and Singapore. The same coding…
Use of technology as an evaluation tool of clinical care in preterm newborns.
Mendes, Izabel; Carvalho, Manoel de; Almeida, Rosimary Terezinha; Moreira, Maria Elizabeth
2006-01-01
To assess the use of the Neonatal Therapeutic Intervention Scoring System (NTISS) as a tool to quantify the use of technology in neonatal intensive care units, in order to detect discrepancies in the care provided to high-risk newborn infants. Prospective, descriptive, observational study about the use of technology in two neonatal intensive care units (one public and one private). The NTISS was calculated on a daily basis up to the discharge or death of preterm newborns with gestational age equal to or less than 32 weeks. We gathered data about prenatal clinical conditions, birth characteristics, and conditions on admission to the intensive care unit, as well as about the morbidities developed during the hospital stay. The risks of preterm newborns were adjusted by means of the Score for Neonatal Acute Physiology, Perinatal Extension, Version II (SNAPPE-II). Student's t test, chi-square test, Fisher's exact test, and the Mann-Whitney/Wilcoxon's test were used for the descriptive analysis. The study was approved by the local Research and Ethics Committee. We assessed 44 newborn infants from the public intensive care unit and 52 from the private one. On admission, the severity score (SNAPPE-II) and the overall NTISS were statistically similar in both care units. The curve for the use of technology showed a gradual and progressive decreasing pattern in both care units up to the 31st day. Thereafter, there was a continuous downward trend in the private care unit, but a significant increase in the overall NTISS in the public care unit. The patients from the public care unit developed more morbidities than those from the private unit. Patients with similar clinical pictures can be treated with different levels of technological resources. This may have a direct impact on morbidities and on healthcare costs. The NTISS allowed monitoring healthcare and proved efficient in detecting discrepancies in practices that could influence clinical outcomes and operating costs.
Nikolaidis, Pantelis T; Clemente, Filipe M; van der Linden, Cornelis M I; Rosemann, Thomas; Knechtle, Beat
2018-01-01
The objectives of the present study were to examine the validity and reliability of the 10 Hz Johan GPS unit in assessing in-line movement and change of direction. The validity was tested against the criterion measure of 200 m track-and-field (track-and-field athletes, n = 8) and 20 m shuttle run endurance test (female soccer players, n = 20). Intra-unit and inter-unit reliability was tested by intra-class correlation coefficient (ICC) and coefficient of variation (CV), respectively. An analysis of variance examined differences between the GPS measurement and five laps of 200 m at 15 km/h, and t -test examined differences between the GPS measurement and 20 m shuttle run endurance test. The difference between the GPS measurement and 200 m distance ranged from -0.13 ± 3.94 m (95% CI -3.42; 3.17) in the first lap to 2.13 ± 2.64 m (95% CI -0.08; 4.33) in the fifth lap. A good intra-unit reliability was observed in 200 m (ICC = 0.833, 95% CI 0.535; 0.962). Inter-unit CV ranged from 1.31% (fifth lap) to 2.20% (third lap). The difference between the GPS measurement and 20 m shuttle run endurance test ranged from 0.33 ± 4.16 m (95% CI -10.01; 10.68) in 11.5 km/h to 9.00 ± 5.30 m (95% CI 6.44; 11.56) in 8.0 km/h. A moderate intra-unit reliability was shown in the second and third stage of the 20 m shuttle run endurance test (ICC = 0.718, 95% CI 0.222;0.898) and good reliability in the fifth, sixth, seventh and eighth (ICC = 0.831, 95% CI -0.229;0.996). Inter-unit CV ranged from 2.08% (11.5 km/h) to 3.92% (8.5 km/h). Based on these findings, it was concluded that the 10 Hz Johan system offers an affordable valid and reliable tool for coaches and fitness trainers to monitor training and performance.
Disinfection of Contaminated Water by Using Solar Irradiation
Caslake, Laurie F.; Connolly, Daniel J.; Menon, Vilas; Duncanson, Catriona M.; Rojas, Ricardo; Tavakoli, Javad
2004-01-01
Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min. PMID:14766599
Testing of refrigerant mixtures in residential heat pumps. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judge, J.F.; Radermacher, R.
1995-08-01
To contribute to finding the proper substitute for R-22, a test facility was designed and built to measure the steady state and cyclic performance of two air-to-air heat pumps of 2 & 3 refrigeration-ton (RT) capacity. The performance of heat pumps is evaluated based on ASHRAE Standard 116-1983 {open_quotes}Method of Testing for Seasonal Efficiency of Unitary Air-conditioners and Heat Pumps{close_quotes} (47). This standard includes six steady-state tests; three cooling tests (A, B, and C) and three heating tests (High Temperature (47S), Frost Accumulation (35F), and Low Temperature (17L)). The standard also includes two cyclic tests; a cyclic cooling test (D)more » and a cyclic heating test (47C). The results of these tests are used to evaluate the seasonal performance of a heat pump. In the work presented here, two heat pumps (test units) are used. Test unit 1 is a 2 RT split heat pump system using a reciprocating compressor, a short tube, and a thermostatic expansion valve. Test unit 2 is a 3 RT split heat pump system using a scroll compressor and two thermostatic expansion valves. This study investigates four different possibilities for replacing R-22 with R-32/125/134a (30/10/60 wt.%) (Mixture 1) or R-32/125/134a (23/25/52 wt.%) (Mixture 2). The first and simplest scenario is the retrofit with no hardware modifications. The second possibility investigated is altering the refrigerant path to attain a near-counterflow configuration in the indoor coil for the heating mode. The third and most complex possibility is the soft optimization which consists of maximizing the COPs of R-22 and Mixture 2 in the heating and cooling modes by optimizing refrigerant charge and expansion devices. The fourth option investigated is the suction-line heat exchange (SLHX). In unit 1, the first, second, and third scenarios are investigated and in unit 2, the first, second, and fourth scenarios are investigated.« less
Cost-effectiveness of population based BRCA testing with varying Ashkenazi Jewish ancestry.
Manchanda, Ranjit; Patel, Shreeya; Antoniou, Antonis C; Levy-Lahad, Ephrat; Turnbull, Clare; Evans, D Gareth; Hopper, John L; Macinnis, Robert J; Menon, Usha; Jacobs, Ian; Legood, Rosa
2017-11-01
Population-based BRCA1/BRCA2 testing has been found to be cost-effective compared with family history-based testing in Ashkenazi-Jewish women were >30 years old with 4 Ashkenazi-Jewish grandparents. However, individuals may have 1, 2, or 3 Ashkenazi-Jewish grandparents, and cost-effectiveness data are lacking at these lower BRCA prevalence estimates. We present an updated cost-effectiveness analysis of population BRCA1/BRCA2 testing for women with 1, 2, and 3 Ashkenazi-Jewish grandparents. Decision analysis model. Lifetime costs and effects of population and family history-based testing were compared with the use of a decision analysis model. 56% BRCA carriers are missed by family history criteria alone. Analyses were conducted for United Kingdom and United States populations. Model parameters were obtained from the Genetic Cancer Prediction through Population Screening trial and published literature. Model parameters and BRCA population prevalence for individuals with 3, 2, or 1 Ashkenazi-Jewish grandparent were adjusted for the relative frequency of BRCA mutations in the Ashkenazi-Jewish and general populations. Incremental cost-effectiveness ratios were calculated for all Ashkenazi-Jewish grandparent scenarios. Costs, along with outcomes, were discounted at 3.5%. The time horizon of the analysis is "life-time," and perspective is "payer." Probabilistic sensitivity analysis evaluated model uncertainty. Population testing for BRCA mutations is cost-saving in Ashkenazi-Jewish women with 2, 3, or 4 grandparents (22-33 days life-gained) in the United Kingdom and 1, 2, 3, or 4 grandparents (12-26 days life-gained) in the United States populations, respectively. It is also extremely cost-effective in women in the United Kingdom with just 1 Ashkenazi-Jewish grandparent with an incremental cost-effectiveness ratio of £863 per quality-adjusted life-years and 15 days life gained. Results show that population-testing remains cost-effective at the £20,000-30000 per quality-adjusted life-years and $100,000 per quality-adjusted life-years willingness-to-pay thresholds for all 4 Ashkenazi-Jewish grandparent scenarios, with ≥95% simulations found to be cost-effective on probabilistic sensitivity analysis. Population-testing remains cost-effective in the absence of reduction in breast cancer risk from oophorectomy and at lower risk-reducing mastectomy (13%) or risk-reducing salpingo-oophorectomy (20%) rates. Population testing for BRCA mutations with varying levels of Ashkenazi-Jewish ancestry is cost-effective in the United Kingdom and the United States. These results support population testing in Ashkenazi-Jewish women with 1-4 Ashkenazi-Jewish grandparent ancestry. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-03-28
The study, conducted by Babcock and Wilcox, was funded by the U.S. Trade and Development agency on behalf of Enelven. In order to maximize generated power output and minimize operating costs at Planta Ramon Laguna, tests were done to evaluate the condition of equipment at the plant. In order to identify any damage and determine the operating output of each unit, assessments were done of the furnaces, boilers, generators and boiler feed pumps being used in the plant. The report presents the results of these tests. This is the second of three volumes and it includes the following section: (1)more » Condition Assessment of Unit RL-10 Boiler.« less
Flight test of an improved solid waste collection system
NASA Technical Reports Server (NTRS)
Thornton, W.; Brasseaux, H.; Whitmore, H.
1991-01-01
A system for human waste collection is described and evaluated on the basis of a prototype employed for the shuttle flight STS-35. The manually operated version of the unit is designed to collect, compact, and store human waste and cleaning material in replaceable volumes. The system is presented with illustrations and descriptions of the disposable pads that are used to clean the cylinder and occlusive air valves as well as seal the unit. Temporary retention and waste entrainment are provided by the variable airflow in the manual unit tested. The prototype testing indicates that sufficient airflow is achieved at 45 CFM and that the stowage volume (18.7 cu in.) is adequate for storing human waste with minimal logistical support. Higher compaction pressure and the use of a directed airstream are proposed for improving the packing efficiency of the unit.
Eight-Year Review of Bordetella pertussis Testing Reveals Seasonal Pattern in the United States.
Bhatti, Micah M; Rucinski, Stefanea L; Schwab, Jeramy J; Cole, Nicolynn C; Gebrehiwot, Senait A; Patel, Robin
2017-03-01
Review of Bordetella pertussis polymerase chain reaction testing from 2007 through 2014 revealed a yearly spike in positivity rates during the summer throughout the United States. Paradoxically, the highest test volumes occurred outside of this time frame, which provides an opportunity for improved test utilization. © The Author 2015. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
1984-01-01
Subtitle) PHASE II TESTING AT 32BA3, S. TYPE OF REPORT & PERIOD COVERED BARNES COUNTY, NORTH DAKOTA. Final 6. PERFORMING ORG. REPORT NUMBER 7 . AUTHOR(a...3 4. Countour map of 32BA418 showing locations of auger test units, 1 m2 test units, cutbank profile (A - A’) and grid system ......... 7 5...Physiographic subdivisions, North Dakota ....... ............. 9 6. Vegetation zones, North Dakota ...... ................... .11 7 . Great Plains
NASA Technical Reports Server (NTRS)
Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.
1990-01-01
The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-14
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model.
Zhang, Yongquan; Tang, Huiming; Li, Changdong; Lu, Guiying; Cai, Yi; Zhang, Junrong; Tan, Fulin
2018-01-01
The physical model test of landslides is important for studying landslide structural damage, and parameter measurement is key in this process. To meet the measurement requirements for deep displacement in landslide physical models, an automatic flexible inclinometer probe with good coupling and large deformation capacity was designed. The flexible inclinometer probe consists of several gravity acceleration sensing units that are protected and positioned by silicon encapsulation, all the units are connected to a 485-comunication bus. By sensing the two-axis tilt angle, the direction and magnitude of the displacement for a measurement unit can be calculated, then the overall displacement is accumulated according to all units, integrated from bottom to top in turn. In the conversion from angle to displacement, two spline interpolation methods are introduced to correct and resample the data; one is to interpolate the displacement after conversion, and the other is to interpolate the angle before conversion; compared with the result read from checkered paper, the latter is proved to have a better effect, with an additional condition that the displacement curve move up half the length of the unit. The flexible inclinometer is verified with respect to its principle and arrangement by a laboratory physical model test, and the test results are highly consistent with the actual deformation of the landslide model. PMID:29342902
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.
2013-01-01
The Advanced Stirling Radioisotope Generator (ASRG) is a high-efficiency generator being developed for potential use on a Discovery 12 space mission. Lockheed Martin designed and fabricated the ASRG Engineering Unit (EU) under contract to the Department of Energy. This unit was delivered to NASA Glenn Research Center in 2008 and has been undergoing extended operation testing to generate long-term performance data for an integrated system. It has also been used for tests to characterize generator operation while varying control parameters and system inputs, both when controlled with an alternating current (AC) bus and with a digital controller. The ASRG EU currently has over 27,000 hours of operation. This paper summarizes all of the tests that have been conducted on the ASRG EU over the past 3 years and provides an overview of the test results and what was learned.
United3D: a protein model quality assessment program that uses two consensus based methods.
Terashi, Genki; Oosawa, Makoto; Nakamura, Yuuki; Kanou, Kazuhiko; Takeda-Shitaka, Mayuko
2012-01-01
In protein structure prediction, such as template-based modeling and free modeling (ab initio modeling), the step that assesses the quality of protein models is very important. We have developed a model quality assessment (QA) program United3D that uses an optimized clustering method and a simple Cα atom contact-based potential. United3D automatically estimates the quality scores (Qscore) of predicted protein models that are highly correlated with the actual quality (GDT_TS). The performance of United3D was tested in the ninth Critical Assessment of protein Structure Prediction (CASP9) experiment. In CASP9, United3D showed the lowest average loss of GDT_TS (5.3) among the QA methods participated in CASP9. This result indicates that the performance of United3D to identify the high quality models from the models predicted by CASP9 servers on 116 targets was best among the QA methods that were tested in CASP9. United3D also produced high average Pearson correlation coefficients (0.93) and acceptable Kendall rank correlation coefficients (0.68) between the Qscore and GDT_TS. This performance was competitive with the other top ranked QA methods that were tested in CASP9. These results indicate that United3D is a useful tool for selecting high quality models from many candidate model structures provided by various modeling methods. United3D will improve the accuracy of protein structure prediction.
Combination of an electrolytic pretreatment unit with secondary water reclamation processes
NASA Technical Reports Server (NTRS)
Wells, G. W.; Bonura, M. S.
1973-01-01
The design and fabrication of a flight concept prototype electrolytic pretreatment unit (EPU) and of a contractor-furnished air evaporation unit (AEU) are described. The integrated EPU and AEU potable water recovery system is referred to as the Electrovap and is capable of processing the urine and flush water of a six-man crew. Results of a five-day performance verification test of the Electrovap system are presented and plans are included for the extended testing of the Electrovap to produce data applicable to the combination of electrolytic pretreatment with most final potable water recovery systems. Plans are also presented for a program to define the design requirements for combining the electrolytic pretreatment unit with a reverse osmosis final processing unit.
Test Driven Development: Lessons from a Simple Scientific Model
NASA Astrophysics Data System (ADS)
Clune, T. L.; Kuo, K.
2010-12-01
In the commercial software industry, unit testing frameworks have emerged as a disruptive technology that has permanently altered the process by which software is developed. Unit testing frameworks significantly reduce traditional barriers, both practical and psychological, to creating and executing tests that verify software implementations. A new development paradigm, known as test driven development (TDD), has emerged from unit testing practices, in which low-level tests (i.e. unit tests) are created by developers prior to implementing new pieces of code. Although somewhat counter-intuitive, this approach actually improves developer productivity. In addition to reducing the average time for detecting software defects (bugs), the requirement to provide procedure interfaces that enable testing frequently leads to superior design decisions. Although TDD is widely accepted in many software domains, its applicability to scientific modeling still warrants reasonable skepticism. While the technique is clearly relevant for infrastructure layers of scientific models such as the Earth System Modeling Framework (ESMF), numerical and scientific components pose a number of challenges to TDD that are not often encountered in commercial software. Nonetheless, our experience leads us to believe that the technique has great potential not only for developer productivity, but also as a tool for understanding and documenting the basic scientific assumptions upon which our models are implemented. We will provide a brief introduction to test driven development and then discuss our experience in using TDD to implement a relatively simple numerical model that simulates the growth of snowflakes. Many of the lessons learned are directly applicable to larger scientific models.
Performance analysis and an assessment of operational issues of Ya-21U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paramonov, D.V.; El-Genk, M.S.
1996-03-01
Extensive testing of the Soviet made TOPAZ-II space nuclear power system unit designated {open_quote}{open_quote}Ya-21U{close_quote}{close_quote} was conducted both in the USSR (1989{endash}1990) and in the US (August 1993 to March 1995). The unit underwent a total of 15 tests for a cumulative test/operation time of almost 8000 hours. These tests included steady-state operation at different power levels, fast startups and power optimizations. Leaks were detected in some of the Thermionic Fuel Elements (TFEs) after the first test in the US. These leaks that facilitated air incursion into the interelectrode gap caused operational changes in both electric power and conversion efficiency andmore » changed the optimum cesium pressure and load voltage. Additional changes in operational performance were detected following shock and vibration tests performed in August 1994. Test data was examined and analyzed to assess the performance of not only individual TFEs, and also the whole Ya-21U unit, and identify causes for measured operational performance changes; most probable causes were identified and discussed. The Ya-21U unit remained operational throughout extensive testing for 8000 hours at conditions far exceeding the design limits of the TOPAZ-II system. No single TFE was damaged during testing and measured operational performance changes were uniform among working section TFEs. In addition to providing a unique knowledge base for future development and operation of thermionic power systems, the test results testify to the reliability and ruggedness of the TOPAZ-II system design. {copyright} {ital 1996 American Institute of Physics.}« less
Physical Science, Units 5 and 6, Field Test Copy.
ERIC Educational Resources Information Center
Washington State Univ., Pullman.
This student workbook contains units five and six of a six-unit physical science course. The program is intended for high school students who have not had a chemistry or physics course, and is designed to be self instructional. Unit five involves experiments and problems in these subject areas: temperature versus heat; units of heat; specific…
Advance prototype silver ion water bactericide system
NASA Technical Reports Server (NTRS)
Jasionowski, W. J.; Allen, E. T.
1974-01-01
An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.
Testing the Birth Unit Design Spatial Evaluation Tool (BUDSET) in Australia: a pilot study.
Foureur, Maralyn J; Leap, Nicky; Davis, Deborah L; Forbes, Ian F; Homer, Caroline E S
2011-01-01
To pilot test the Birth Unit Design Spatial Evaluation Tool (BUDSET) in an Australian maternity care setting to determine whether such an instrument can measure the optimality of different birth settings. Optimally designed spaces to give birth are likely to influence a woman's ability to experience physiologically normal labor and birth. This is important in the current industrialized environment, where increased caesarean section rates are causing concerns. The measurement of an optimal birth space is currently impossible, because there are limited tools available. A quantitative study was undertaken to pilot test the discriminant ability of the BUDSET in eight maternity units in New South Wales, Australia. Five auditors trained in the use of the BUDSET assessed the birth units using the BUDSET, which is based on 18 design principles and is divided into four domains (Fear Cascade, Facility, Aesthetics, and Support) with three to eight assessable items in each. Data were independently collected in eight birth units. Values for each of the domains were aggregated to provide an overall Optimality Score for each birth unit. A range of Optimality Scores was derived for each of the birth units (from 51 to 77 out of a possible 100 points). The BUDSET identified units with low-scoring domains. Essentially these were older units and conventional labor ward settings. The BUDSET provides a way to assess the optimality of birth units and determine which domain areas may need improvement. There is potential for improvements to existing birth spaces, and considerable improvement can be made with simple low-cost modifications. Further research is needed to validate the tool.
August 5, 1963-President Kennedy's Nuclear Test Ban Treaty signed in Moscow, Russia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kennedy, John F.
On August 5, 1963, after more than eight years of negotiations, the United States, the United Kingdom, and the Soviet Union signed the Limited Nuclear Test Ban Treaty. The destruction of Hiroshima and Nagasaki by atomic bombs marked the end of World War II and the beginning of the nuclear age. As tensions between East and West settled into a Cold War, scientists in the United States, Great Britain, and the Soviet Union conducted tests and developed more powerful nuclear weapons. In 1959, radioactive deposits were found in wheat and milk in the northern United States. As scientists and themore » public gradually became aware of the dangers of radioactive fallout, they began to raise their voices against nuclear testing. Leaders and diplomats of several countries sought to address the issue. In May 1955, the United Nations Disarmament Commission brought together the United States, the United Kingdom, Canada, France, and the Soviet Union to begin negotiations on ending nuclear weapons testing. Conflict soon arose over inspections to verify underground testing. The Soviet Union feared that on-site inspections could lead to spying that might expose the Soviets' vastly exaggerated claims of the number of deliverable nuclear weapons. As negotiators struggled over differences, the Soviet Union and the United States suspended nuclear tests—a moratorium that lasted from November 1958 to September 1961. John F. Kennedy had supported ban on nuclear weapons testing since 1956. He believed a ban would prevent other countries from obtaining nuclear weapons, and took a strong stand on the issue in the 1960 presidential campaign. Once elected, President Kennedy pledged not to resume testing in the air and promised to pursue all diplomatic efforts for a test ban treaty before resuming underground testing. He envisioned the test ban as a first step to nuclear disarmament. President Kennedy met with Soviet Premier Khrushchev in Vienna in June 1961, just five weeks after the humiliating defeat of the US-sponsored invasion of Cuba at the Bay of Pigs. Khrushchev took a hard line at the summit. He announced his intention to cut off Western access to Berlin and threatened war if the United States or its allies tried to stop him. Many US diplomats felt that Kennedy had not stood up to the Soviet premier at the summit and left Khrushchev with the impression that he was a weak leader. President Kennedy's political and military advisers feared that the Soviet Union had continued secret underground testing and made gains in nuclear technology. They pressured Kennedy to resume testing. And, according to a Gallup poll in July 1961, the public approved of testing by a margin of two-to-one. In August 1961, the Soviet Union announced its intention to resume atmospheric testing, and over the next three months it conducted 31 nuclear tests. It exploded the largest nuclear bomb in history—58 megatons—4,000 times more powerful than the bomb dropped on Hiroshima. In his commencement address at American University on June 10, 1963, Kennedy announced a new round of high-level arms negotiations with the Russians. He boldly called for an end to the Cold War. "If we cannot end our differences," he said, "at least we can help make the world a safe place for diversity." The Soviet government broadcast a translation of the entire speech, and allowed it to be reprinted in the controlled Soviet press. The Limited Nuclear Test Ban treaty was signed in Moscow on August 5, 1963, by US Secretary Dean Rusk, Soviet Foreign Minister Andrei Gromyko, and British Foreign Secretary Lord Home—one day short of the 18th anniversary of the dropping of an atomic bomb on Hiroshima. Over the next two months, President Kennedy convinced a fearful public and a divided Senate to support the treaty. The Senate approved the treaty on September 23, 1963, by an 80-19 margin. Kennedy signed the ratified treaty on October 7, 1963. The treaty: prohibited nuclear weapons tests or other nuclear explosions under water, in the atmosphere, or in outer space allowed underground nuclear tests as long as no radioactive debris falls outside the boundaries of the nation conducting the test pledged signatories to work towards complete disarmament, an end to the armaments race, and an end to the contamination of the environment by radioactive substances. Thirty-three years later, the United Nations General Assembly adopted the Comprehensive Nuclear Test Ban Treaty. Signed by 71 nations, including those possessing nuclear weapons, the treaty prohibited all nuclear test explosions including those conducted underground. Though it was signed by President Bill Clinton, the Senate rejected the treaty by a vote of 51 to 48.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2010 CFR
2010-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2013 CFR
2013-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2011 CFR
2011-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
United Stirling's Solar Engine Development: the Background for the Vanguard Engine
NASA Technical Reports Server (NTRS)
Holgersson, S.
1984-01-01
The development and testing resulting in the Vanguard engine and some of the characteristics of the Stirling engine based power conversion unit are described. The major part of the solar engine development is concentrated to the three different areas, the receiver, the lubrication system and the control system. Five engines are on test within the solar project. The function of the components are validated in actual solar tests.
ERIC Educational Resources Information Center
Kouimanos, John, Ed.
Accompanying a multimedia resource unit on aspects of rice growing, volume eight of the geography collection includes a section introducing terminology, a viewing guide to the filmstrips and unit test items. Rice farming and marketing in Australia and growing methods in several countries are presented with regional studies in southeast Australia.…
ETR ELECTRICAL BUILDING, TRA648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. ...
ETR ELECTRICAL BUILDING, TRA-648. EMERGENCY STANDBY GENERATOR AND DIESEL UNIT. METAL ROOF AND PUMICE BLOCK WALLS. CAMERA FACING SOUTHWEST. INL NEGATIVE NO. 56-3708. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Astronaut Bruce McCandless during an underwater test MMU/FSS in bldg 29 WETF
1981-08-04
Astronaut Bruce McCandless during an underwater test of the Manned Maneuvering Unit (MMU) Flight Support Station (FSS) donning and doffing in the Bldg 29 Weightless Environment Training Facility (WETF). View is of McCandless wearing the extravehicular mobility unit (EMU), stepping into the MMU.
DOT National Transportation Integrated Search
2002-06-01
The objective of this study was to investigate the effect of moisture content and dry unit weight on the resilient characteristics of subgrade soil predicted by the cone penetration test. An experimental program was conducted in which cone penetratio...
Walker, Tiffany A; Lockhart, Shawn R; Beekmann, Susan E; Polgreen, Philip M; Santibanez, Scott; Mody, Rajal K; Beer, Karlyn D; Chiller, Tom M; Jackson, Brendan R
2018-01-01
Infections caused by pan-azole-resistant Aspergillus fumigatus strains have emerged in Europe and recently in the United States. Physicians specializing in infectious diseases reported observing pan-azole-resistant infections and low rates of susceptibility testing, suggesting the need for wider-scale testing.
Lockhart, Shawn R.; Beekmann, Susan E.; Polgreen, Philip M.; Santibanez, Scott; Mody, Rajal K.; Beer, Karlyn D.; Chiller, Tom M.; Jackson, Brendan R.
2018-01-01
Infections caused by pan–azole-resistant Aspergillus fumigatus strains have emerged in Europe and recently in the United States. Physicians specializing in infectious diseases reported observing pan–azole-resistant infections and low rates of susceptibility testing, suggesting the need for wider-scale testing. PMID:29261092
Code of Federal Regulations, 2013 CFR
2013-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
Code of Federal Regulations, 2012 CFR
2012-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
Code of Federal Regulations, 2014 CFR
2014-07-01
... (NSPS) for Particulate Matter (PM) 4 Table 4 to Subpart UUU of Part 63 Protection of Environment... Units Pt. 63, Subpt. UUU, Table 4 Table 4 to Subpart UUU of Part 63—Requirements for Performance Tests...
NASA Astrophysics Data System (ADS)
Chu, Hsiao-Ping; Chang, Tsangyao; Chang, Hsu-Ling; Su, Chi-Wei; Yuan, Young
2007-10-01
Here, the Panel seemingly unrelated regressions augmented Dickey-Fuller test (SURADF) test, first introduced and advanced by Breuer et al. [Misleading inferences from panel unit-root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9(3) (2001) 482-493], is used to investigate the mean-reverting behavior of the current account of 48 African countries during the 1980-2004 periods. The empirical results from numerous panel-based unit root tests, conducted earlier, indicated that the current account of each of these countries is stationary; however, when Breuer et al.'s (2001) Panel SURADF test is conducted, it is found that a unit root exists in the current account of 11 of the countries studied. These results have one extremely important policy implication for the 48 African countries studied: the current account deficit of most is sustainable, and thus signifying that those nations should have no incentive to default on their international debt.
Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina
2009-01-01
The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.
Experimental Results From a 2kW Brayton Power Conversion Unit
NASA Technical Reports Server (NTRS)
Hervol, David; Mason, Lee; Birchenough, Arthur
2003-01-01
This paper presents experimental test results from operation of a 2 kWe Brayton power conversion unit. The Brayton converter was developed for a solar dynamic power system flight experiment planned for the Mir Space Station in 1997. The flight experiment was cancelled, but the converter was tested at Glenn Research Center as part of the Solar Dynamic Ground Test Demonstration system which included a solar concentrator, heat receiver, and space radiator. In preparation for the current testing, the heat receiver was removed and replaced with an electrical resistance heater, simulating the thermal input of a steady-state nuclear source. The converter was operated over a full range of thermal input power levels and rotor speeds to generate an overall performance map. The converter unit will serve as the centerpiece of a Nuclear Electric Propulsion Testbed at Glenn. Future potential uses for the Testbed include high voltage electrical controller development, integrated electric thruster testing and advanced radiator demonstration testing to help guide high power Brayton technology development for Nuclear Electric Propulsion (NEP).
Will the leading firm continue to dominate the market in the Taiwan notebook industry?
NASA Astrophysics Data System (ADS)
Chu, Hsiao-Ping; Yeh, Ming-Liang; Sher, Peter J.; Chiu, Yi-Chia
2007-09-01
This study investigates whether the market share leader in the notebook industry in Taiwan is likely to maintain its dominant position. Market share data are used to investigate the intensity of competitiveness in the industry, and data on the gap in market shares are employed to elucidate the dominance of the leading firm in Taiwan's notebook industry during the 1998-2004 period. The newly developed Panel SURADF tests advanced by Breuer et al. [Misleading inferences from panel unit root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9 (3) (2001) 482-493] are employed to determine whether the market share gap is stationary or not. Unlike other panel-based unit root tests which are joint tests of a unit root for all members of a panel and are incapable of determining the mix of I(0) and I(1) series in a panel setting, the Panel SURADF tests have the advantage of being able to investigate a separate unit root null hypothesis for each individual panel member and are, therefore, able to identify how many and which series in a panel are stationary processes. The empirical results from several panel-based unit root tests substantiate that the market shares of the firms studied here are non-stationary, indicating that Taiwan's notebook industry is highly competitive; however, Breuer et al.'s [12] Panel SURADF tests unequivocally show that only Compal is stationary with respect to market share gap. In terms of sales volume, Compal is the second largest firm in the notebook industry in Taiwan, and the results indicate that it alone has the opportunity to become the market share leader in the notebook industry.
Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H
1990-11-08
We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.
Gonthier, Gerard
2012-01-01
Two test wells were completed in Pooler, Georgia, in 2011 to investigate the potential of using the Lower Floridan aquifer as a source of water for municipal use. One well was completed in the Lower Floridan aquifer at a depth of 1,120 feet (ft) below land surface; the other well was completed in the Upper Floridan aquifer at a depth of 486 ft below land surface. At the Pooler test site, the U.S. Geological Survey performed flowmeter surveys, packer-isolated slug tests within the Lower Floridan confining unit, slug tests of the entire Floridan aquifer system, and aquifer tests of the Upper and Lower Floridan aquifers. Drill cuttings, geophysical logs, and borehole flowmeter surveys indicate that the Upper Floridan aquifer extends 333 –515 ft below land surface, the Lower Floridan confining unit extends 515–702 ft below land surface, and the Lower Floridan aquifer extends 702–1,040 ft below land surface. Flowmeter surveys indicate that the Upper Floridan aquifer contains two water-bearing zones at depth intervals of 339 –350 and 375–515 ft; the Lower Floridan confining unit contains one zone at a depth interval of 550–620 ft; and the Lower Floridan aquifer contains five zones at depth intervals of 702–745, 745–925, 925–984, 984–1,015, and 1,015–1,040 ft. Flowmeter testing of the test borehole open to the entire Floridan aquifer system indicated that the Upper Floridan aquifer contributed 92.4 percent of the total flow rate of 708 gallons per minute; the Lower Floridan confining unit contributed 3.0 percent; and the Lower Floridan aquifer contributed 4.6 percent. Horizontal hydraulic conductivity of the Lower Floridan confining unit derived from slug tests within three packer-isolated intervals ranged from 0.5 to 10 feet per day (ft/d). Aquifer-test analyses yielded values of transmissivity for the Upper Floridan aquifer, Lower Floridan confining unit, and the Lower Floridan aquifer of 46,000, 700, and 4,000 feet squared per day (ft2/d), respectively. Horizontal hydraulic conductivity of 4 ft/d for the Lower Floridan confining unit, derived from aquifer-test analyses, is near the midrange for values derived from packer-isolated slug tests. The transmissivity of the entire Floridan aquifer system derived from aquifer-test analyses totals about 51,000 ft2/d, similar to the value of 58,000 ft2/d derived from open slug tests on the entire Floridan aquifer system. Water-level data for each aquifer test were filtered for external influences such as barometric pressure, earth-tide effects, and long-term trends to enable detection of small (less than 1 foot) water-level responses to aquifer-test pumping. During the 72-hour aquifer test of pumping the Lower Floridan aquifer, a drawdown response of 51.7 ft was observed in the Lower Floridan pumped well and a drawdown response of 0.9 foot was observed in the Upper Floridan observation well located 85 ft from the pumped well.
Advanced Stirling Radioisotope Generator Engineering Unit 2 (ASRG EU2) Final Assembly
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2015-01-01
NASA Glenn Research Center (GRC) has recently completed the assembly of a unique Stirling generator test article for laboratory experimentation. Under the Advanced Stirling Radioisotope Generator (ASRG) flight development contract, NASA GRC initiated a task to design and fabricate a flight-like generator for in-house testing. This test article was given the name ASRG Engineering Unit 2 (EU2) as it was effectively the second engineering unit to be built within the ASRG project. The intent of the test article was to duplicate Lockheed Martin's qualification unit ASRG design as much as possible to enable system-level tests not previously possible at GRC. After the cancellation of the ASRG flight development project, the decision was made to continue the EU2 build, and make use of a portion of the hardware from the flight development project. GRC and Lockheed Martin engineers collaborated to develop assembly procedures, leveraging the valuable knowledge gathered by Lockheed Martin during the ASRG development contract. The ASRG EU2 was then assembled per these procedures at GRC with Lockheed Martin engineers on site. The assembly was completed in August 2014. This paper details the components that were used for the assembly, and the assembly process itself.
Field Test of the Unit Equal Opportunity Training Diagnosis and Assessment System (TDAS)
1980-02-01
Reseiirch Note 80-38 In U FIELD TEST OF THE UNIT EQUAL OPPORTUNITY TRAINING DIAGNOSIS AND ASSESSMENT SYSTEM (TDAS) 0 Dale K. Brown Human Sciences... Social Sciences February 1980 S Aoproved for public release; distribution unlimited. 84 11 O6 0 0- 7 9 THIS REPORT IS INCOMPLETE BUT IS THE BEST AVAILABLE...likely to be a unit problem area to that least likely. Four attitude scales are also included, as is a measure of knowledge of Army equal opportunity
Pathogen Reduction of Fresh Whole Blood for Military and Civilian Use
2010-04-01
NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT...treatment with 80 J/mLRBC in the Mirasol System. Strain of bacteria tested # of units positive/ # of units tested Serratia marcescens 0/3 Yersinia
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
49 CFR 234.253 - Flashing light units and lamp voltage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Flashing light units and lamp voltage. 234.253....253 Flashing light units and lamp voltage. (a) Each flashing light unit shall be inspected when... with installation specifications. (b) Lamp voltage shall be tested when installed and at least once...
Comparative performance tests on the Mod-2, 2.5-mW wind turbine with and without vortex generators
NASA Technical Reports Server (NTRS)
Miller, G. E.
1995-01-01
A test program was conducted on the third Mod-2 unit at Goldendale, Washington, to systematically study the effect of vortex generators (VG's) on power performance. The subject unit was first tested without VG's to obtain baseline data. Vortex generators were then installed on the mid-blade assemblies, and the resulting 70% VG configuration was tested. Finally, vortex generators were mounted on the tip assemblies, and data was recorded for the 100% VG configuration. This test program and its results are discussed in this paper. The development of vortex generators is also presented.
Development and testing of a source subsystem for the supporting development PMAD DC test bed
NASA Technical Reports Server (NTRS)
Button, Robert M.
1991-01-01
The supporting Development Power Management and Distribution (PMAD) DC Test Bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC Test Bed was systematically integrated. The Source Subsystem of the PMAD DC Test Bed consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU) is introduced. The SSU is described in detail and component level test data is presented. Next, the BCDU's operation and design is given along with component level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giovanni, D.V.; Carr, R.C.; Landham, E.C.
Two products of coal quality research at the Electric Power Research Institute TM (EPRI) are available for field evaluation: Coal Quality Impact Model (CQIM and Fireside Testing Guidelines (FIG). The CQIM is a computer program that may be tailored to simulate the performance characteristics of a coal-fired power plant. The FIG is a technical report that guides utilities in conducting field tests to gather performance data and quantify the technical and economic impacts of different coals. Moreover, the results from field tests may be utilized to validate and assess the applicability of the CQIM. Field tests were conducted at Mississippimore » Power Company`s Watson Unit 4 to evaluate the coal quality impacts of coal switching on boiler performance and emissions. Watson Unit 4 is a 255 MW (gross), opposed-wall, pulverized-coal-fired boiler manufactured by Riley Stoker Corporation and rated at 1,779,000 lb/hr steam flow at 1000{degrees}F superheat steam temperature and 2,500 psig. The unit is equipped with a cold-side electrostatic precipitator for particulate matter control. Comprehensive tests were conducted on all major equipment components, including the pulverizers, fans, combustion equipment, boiler heat transfer surfaces, air preheater, and electrostatic precipitator, for two coals. The CQIN4 was configured to predict the performance of the unit when burning each coal. The work was sponsored by EPRI, and Mississippi Power Company (MPC) was the host utility company. This report summarizes results from the field test program, including potential heat rate improvements that were identified, and the differences in unit operations and performance for the two coals. The results from the CQIM validation effort are also presented.« less
[Portable multi-purpose device for monitoring of physiological informations].
Tamura, T; Togawa, T
1983-05-01
Unconstrained system that measures physiological information as skin temperatures and heart rate per unit time of a human subject was developed. The system contained portable device included memory control unit, instrumentation unit, timer and batteries, read-out unit, test unit and verify unit. Total number of data and channels, and interval were selected by switches in the memory control unit. The data from the instrumentation unit were transferred to memory control unit and stored in the Erasable Programmable ROM (EPROM). After measurement, EPROM chip was taken off the memory control unit and put on the read-out unit which transferred the data to the microcomputer. The data were directly calculated and analyzed by microcomputer. In application of the instrumentation unit, 8-channel skin thermometer was developed and tested. After amplification, 8 analog signals were multiplexed and converted into the binary codes. The digital signals were sequentially transferred to memory control unit and stored in the EPROM under controlled signal. The accuracy of the system is determined primarily by the accuracy of the sensor of instrumentation unit. The overall accuracy of 8-channel skin thermometer is conservatively stated within 0.1 degree C. This may prove to be useful in providing an objective measurement of human subjects, and can be used in studying environmental effect for human body and sport activities in a large population setting.
Aetiology of obstructive azoospermia in Chinese infertility patients.
Han, H; Liu, S; Zhou, X-G; Tian, L; Zhang, X-D
2016-09-01
To explore the aetiology of obstructive azoospermia (OA) in Chinese infertility patients, 133 OA patients was included in this study diagnosed and evaluated by one major specialist trained urological infertility. We retrospected the medical records to collect relative information. All of the patients had been underwent physical examination, ultrasound scan to the urogenital system, serum hormone tests, genetic tests and two separate semen analyses. The mean age of all 133 patients was 32.7 ± 6.8 years. A total of 266 reproductive tract units (two/patient) were classified into four categories: no causes (Idiopathic) for 74 units (27.8%), single cause for 173 units (65.0%), double causes for 17 units (6.4%) and triple causes for two units (0.8%). As to single cause of OA, there were four types: trauma for 0 unit (0%), infection for 125 units (47.0%), dysplasia for 11 units (4.1%) and surgeries for 37 units (13.9%). As to total cause of OA, there were five types: infection for 144 units (54.1%), orchitis for 51 units (19.2%), epididymitis for 54 units (20.3%), gonorrhoea for 28 units (10.5%) and inguinal hernia repair surgery for 18 units (6.8%). The most frequent cause of obstructive azoospermia was infection revealed in these Chinese infertility populations, followed by idiopathic reason. © 2015 Blackwell Verlag GmbH.
Cold-end Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodium-potassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated cold-end fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to high-cost composite radiators in an end-to-end TDU test.
Cold-End Subsystem Testing for the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Mazwell; Gibson, Marc; Ellis, David; Sanzi, James
2013-01-01
The Fission Power System (FPS) Technology Demonstration Unit (TDU) consists of a pumped sodiumpotassium (NaK) loop that provides heat to a Stirling Power Conversion Unit (PCU), which converts some of that heat into electricity and rejects the waste heat to a pumped water loop. Each of the TDU subsystems is being tested independently prior to full system testing at the NASA Glenn Research Center. The pumped NaK loop is being tested at NASA Marshall Space Flight Center; the Stirling PCU and electrical controller are being tested by Sunpower Inc.; and the pumped water loop is being tested at Glenn. This paper describes cold-end subsystem setup and testing at Glenn. The TDU cold end has been assembled in Vacuum Facility 6 (VF 6) at Glenn, the same chamber that will be used for TDU testing. Cold-end testing in VF 6 will demonstrate functionality; validated coldend fill, drain, and emergency backup systems; and generated pump performance and system pressure drop data used to validate models. In addition, a low-cost proof-of concept radiator has been built and tested at Glenn, validating the design and demonstrating the feasibility of using low-cost metal radiators as an alternative to highcost composite radiators in an end-to-end TDU test.
Development Status of the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Pearson, Jon Boise; Godfoy, Thomas
2012-01-01
This paper summarizes the progress that has been made in the development of the Fission Power System Technology Demonstration Unit (TDU). The reactor simulator core and Annular Linear Induction Pump have been fabricated and assembled into a test loop at the NASA Marshall Space Flight Center. A 12 kWe Power Conversion Unit (PCU) is being developed consisting of two 6 kWe free-piston Stirling engines. The two 6 kWe engines have been fabricated by Sunpower Inc. and are currently being tested separately prior to integration into the PCU. The Facility Cooling System (FCS) used to reject convertor waste heat has been assembled and tested at the NASA Glenn Research Center (GRC). The structural elements, including a Buildup Assembly Platform (BAP) and Upper Truss Structure (UTS) have been fabricated, and will be used to test cold-end components in thermal vacuum prior to TDU testing. Once all components have been fully tested at the subsystem level, they will be assembled into an end-to-end system and tested in thermal vacuum at GRC.
Development Status of the Fission Power System Technology Demonstration Unit
NASA Technical Reports Server (NTRS)
Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M; Pearson, Jon Boise; Godfroy, Thomas
2012-01-01
This paper summarizes the progress that has been made in the development of the Fission Power System Technology Demonstration Unit (TDU). The reactor simulator core and Annular Linear Induction Pump have been fabricated and assembled into a test loop at the NASA Marshall Space Flight Center. A 12 kWe Power Conversion Unit (PCU) is being developed consisting of two 6 kWe free-piston Stirling engines. The two 6 kWe engines have been fabricated by Sunpower Inc. and are currently being tested separately prior to integration into the PCU. The Facility Cooling System (FCS) used to reject convertor waste heat has been assembled and tested at the NASA Glenn Research Center (GRC). The structural elements, including a Buildup Assembly Platform (BAP) and Upper Truss Structure (UTS) have been fabricated, and will be used to test cold-end components in thermal vacuum prior to TDU testing. Once all components have been fully tested at the subsystem level, they will be assembled into an end-to-end system and tested in thermal vacuum at NASA GRC.
Field Tests of Wind Turbine Unit with Tandem Wind Rotors and Double Rotational Armatures
NASA Astrophysics Data System (ADS)
Galal, Ahmed Mohamed; Kanemoto, Toshiaki
This paper discusses the field tests of the wind turbine unit, in which the front and the rear wind rotors drive the inner and the outer armatures of the synchronous generator. The wind rotors were designed conveniently by the traditional procedure for the single wind rotor, where the diameters of the front and the rear wind rotors are 2 m and 1.33 m. The tests were done on a pick-up type truck driven straightly at constant speed. The rotational torque of the unit is directly proportional to the induced electric current irrespective of the rotational speeds of the wind rotors, while the induced voltage is proportional to the relative rotational speed. The performance of the unit is significantly affected not only by the wind velocity, but also by the blade setting angles of both wind rotors and the applied load especially at lower wind velocity.
Guidelines for testing and release procedures
NASA Technical Reports Server (NTRS)
Molari, R.; Conway, M.
1984-01-01
Guidelines and procedures are recommended for the testing and release of the types of computer software efforts commonly performed at NASA/Ames Research Center. All recommendations are based on the premise that testing and release activities must be specifically selected for the environment, size, and purpose of each individual software project. Guidelines are presented for building a Test Plan and using formal Test Plan and Test Care Inspections on it. Frequent references are made to NASA/Ames Guidelines for Software Inspections. Guidelines are presented for selecting an Overall Test Approach and for each of the four main phases of testing: (1) Unit Testing of Components, (2) Integration Testing of Components, (3) System Integration Testing, and (4) Acceptance Testing. Tools used for testing are listed, including those available from operating systems used at Ames, specialized tools which can be developed, unit test drivers, stub module generators, and the use of format test reporting schemes.
ERIC Educational Resources Information Center
Miyamoto, Kenichiro
2008-01-01
Every state in the United States, under the NCLB act, has set state standards and is testing all students in grades 3-8. Students are given printed questions to which they write answers with a pencil on an answer sheet. These written tests are usually given to determine the academic achievements of students. This paper traces the early history of…
NASA Technical Reports Server (NTRS)
Tobey, G. L.
1978-01-01
Tests were performed to evaluate the operating characteristics of the interface between the Space Lab Bus Interface Unit (SL/BIU) and the Orbiter Multiplexer-Demultiplexer (MDM) serial data input-output (SIO) module. This volume contains the test equipment preparation procedures and a detailed description of the Nova/Input Output Processor Simulator (IOPS) software used during the data transfer tests to determine word error rates (WER).
2014-03-14
NUMBER FA8201-09-D-0002 Overhaul Complex at Little Mountain Test Annex, Utah 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Streamline Consulting, LLC 1713 N. Sweetwater Lane Farmington, Utah 84025...Hill Air Force Base (AFB) proposes to construct a new emergency power unit overhaul complex at Little Mountain Test Annex, Utah . Buildings 2005
Experimental Data for Two Different Alternator Configurations in a Solar Brayton Power System
NASA Technical Reports Server (NTRS)
Mason, Lee S.; Shaltens, Richard K.; Espinosa, William D.
1997-01-01
A solar dynamic (SD) space power system has been under test at the NASA Lewis Research Center since 1994. The SD Ground Test Demonstration (GTD) system includes a solar concentrator, heat receiver with thermal energy storage, Brayton power conversion unit, and radiator installed in a thermal-vacuum chamber with a solar simulator. The Brayton unit has been operated with two different turboalternator compressor (TAC) assemblies, one which included a Rice Lundell alternator and another which incorporated a permanent magnet (PM) alternator. The Rice alternator was part of the mini-Brayton rotating unit, designed and built during the 1970's and refurbished for the GTD. The PM TAC was a development unit from the Joint US/Russian SD Flight Project. This paper highlights the operational differences (and similarities) between the Rice and PM TAC configurations including a comparative evaluation of startup characteristics and operating performance. The two alternator configurations were tested under similar thermal conditions, as an interchangeable component within the SD system. The electrical characteristics of the two units, however, dictated the use of significantly different power conditioning and control strategies. The electrical control architectures are described and compared. Test data are presented on TAC startup and system operating performance for both configurations.
High Voltage Hall Accelerator Propulsion System Development for NASA Science Missions
NASA Technical Reports Server (NTRS)
Kamhawi, Hani; Haag, Thomas; Huang, Wensheng; Shastry, Rohit; Pinero, Luis; Peterson, Todd; Dankanich, John; Mathers, Alex
2013-01-01
NASA Science Mission Directorates In-Space Propulsion Technology Program is sponsoring the development of a 3.8 kW-class engineering development unit Hall thruster for implementation in NASA science and exploration missions. NASA Glenn Research Center and Aerojet are developing a high fidelity high voltage Hall accelerator (HiVHAc) thruster that can achieve specific impulse magnitudes greater than 2,700 seconds and xenon throughput capability in excess of 300 kilograms. Performance, plume mappings, thermal characterization, and vibration tests of the HiVHAc engineering development unit thruster have been performed. In addition, the HiVHAc project is also pursuing the development of a power processing unit (PPU) and xenon feed system (XFS) for integration with the HiVHAc engineering development unit thruster. Colorado Power Electronics and NASA Glenn Research Center have tested a brassboard PPU for more than 1,500 hours in a vacuum environment, and a new brassboard and engineering model PPU units are under development. VACCO Industries developed a xenon flow control module which has undergone qualification testing and will be integrated with the HiVHAc thruster extended duration tests. Finally, recent mission studies have shown that the HiVHAc propulsion system has sufficient performance for four Discovery- and two New Frontiers-class NASA design reference missions.
Age-related motor unit remodeling in the Tibialis Anterior.
Siddiqi, Ariba; Kumar, Dinesh; Arjunan, Sridhar
2015-01-01
Limited studies exist on the use of surface electromyogram (EMG) signal features to detect age-related motor unit remodeling in the Tibialis Anterior. Motor unit remodeling leads to declined muscle strength and force steadiness during submaximal contractions which are factors for risk of falls in the elderly. This study investigated the remodeling phenomena in the Tibialis Anterior using sample entropy and higher order statistics. Eighteen young (26.1 ± 2.9 years) and twelve elderly (68.7 ± 9.0 years) participants performed isometric dorsiflexion of the ankle at 20% maximal voluntary contraction (MVC) and their Tibialis Anterior (TA) EMG was recorded. Sample entropy, Gaussianity and Linearity Test statistics were calculated from the recorded EMG for each MVC. Shapiro-Wilk test was used to determine normality, and either a two-tail student t-test or Wilcoxon rank sum test was performed to determine significant difference in the EMG features between the young and old cohorts. Results show age-related motor unit remodeling to be depicted by decreased sample entropy (p <; 0.1), increased non-Gaussianity (p <; 0.05) and lesser degree of linearity in the elderly. This is due to the increased sparsity of the MUAPs as a result of the denervation-reinnervation process, and the decrease in total number of motor units.
NASA Astrophysics Data System (ADS)
Urbahs, A.; Urbaha, M.; Carjova, K.
2017-10-01
The theoretical calculation for development of planetary gear unit of wind turbine (WT) and its experimental tests are presented in the paper. Development of experimental prototypes from composite materials is essential to determine capability of element and its impact on feature. Two experimental scale prototypes of planetary gear unit for WT were developed for such purposes. Hall transducer, servomechanisms and optical tachometers were used to obtain results, comparison analysis of theoretical and actual data was performed as well as quality assessment of experimental prototypes of planetary gear unit. After kinematic and load analysis as well as control of rotation frequency, it is possible to declare that the unit is able to operate at designated quality. Theoretical calculations and test results obtained are used for industrial WT prototype development.
Gestational Trophoblastic Disease Diagnosis Delayed by the Hook Effect.
Cormano, Julia; Mackay, Gillian; Holschneider, Christine
2015-10-01
A "hook effect" resulting from saturation of antibodies used in pregnancy tests can occur at human chorionic gonadotropin (hCG) levels above 500,000 milliinternational units/mL, resulting in falsely negative values. A 34-year-old woman, gravida 5 para 3, presented to the emergency department after heavy bleeding. Ultrasonogram revealed a uterine mass, urine pregnancy test result was negative, and endometrial biopsy inconclusive. The patient was discharged and presented 10 days later with recurrent bleeding. Urine pregnancy test result was again negative, but serum hCG was 581 milliinternational units/mL. Serial dilution revealed an actual hCG higher than 5 million milliinternational units/mL. She was diagnosed with gestational trophoblastic disease. Awareness of the risk of a false-negative pregnancy test result when hCG levels are extremely high may prevent delayed diagnosis of gestational trophoblastic disease.
Sporicidal activity of a new low-temperature sterilization technology: the Sterrad 50 sterilizer.
Rutala, W A; Gergen, M F; Weber, D J
1999-07-01
This study was undertaken to evaluate the efficacy of a new low-temperature sterilization system that recently has been cleared by the Food and Drug Administration, the Sterrad 50. Flat stainless steel carriers were inoculated with approximately 10(6) Bacillus stearothermophilus spores. These carriers were placed aseptically in the middle of 40-cm-long stainless steel-lumened test units of varying diameters (1 mm, 2 mm, and 3 mm). After inoculation, the test units were processed in the Sterrad 50. After sterilization, the carriers were assayed for growth of the B. stearothermophilus spores. Our data demonstrated that the Sterrad 50 was highly effective in killing the B. stearothermophilus spores (no positive carriers with 30 tests of each lumen-diameter test unit). The Sterrad 50 is likely to be clinically useful for the sterilization of heat-sensitive medical equipment.
Increasing Inferential Leverage in the Comparative Method: Placebo Tests in Small-"n" Research
ERIC Educational Resources Information Center
Glynn, Adam N.; Ichino, Nahomi
2016-01-01
We delineate the underlying homogeneity assumption, procedural variants, and implications of the comparative method and distinguish this from Mill's method of difference. We demonstrate that additional units can provide "placebo" tests for the comparative method even if the scope of inference is limited to the two units under comparison.…
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
30 CFR 74.5 - Tests of coal mine dust personal sampler units.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of coal mine dust personal sampler units. 74.5 Section 74.5 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH COAL MINE DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust...
Color Vision Deficiencies in Children. United States.
ERIC Educational Resources Information Center
National Center for Health Statistics (DHEW/PHS), Hyattsville, MD.
Presented are prevalence data on color vision deficiencies (color blindness) in noninstitutionalized children, aged 6-11, in the United States, as estimated from the Health Examination Survey findings on a representative sample of over 7,400 children. Described are the two color vision tests used in the survey, the Ishihara Test for Color…
The report gives results of the collection of emissions test data st two triethylene glycol units to provide data for the comparison to GRI-GLYCalc, a computer program developed to estimate emissions from glycol dehydrators. [NOTE: Glycol dehydrators are used in the natural gas i...
The report gives results of the collection of emissions tests data at two triethylene glycol units to provide data for comparison to GRI-GLYCalc, a computer program developed to estimate emissions from glycol dehydrators. (NOTE: Glycol dehydrators are used in the natural gas indu...
Year 6 Planning Exemplification 3. National Literacy Strategy.
ERIC Educational Resources Information Center
Department for Education and Skills, London (England).
Third in a series of booklets designed to assist Year 6 teachers with planning instruction to meet objectives of the National Literacy Strategy, this booklet contains Summer Term planning exemplification for three "revision" units (Narrative, Poetry and Non-fiction) prior to the Key Stage 2 tests and one unit after the tests (Extended…
Students' Illustrations of the Human Nervous System as a Formative Assessment Tool
ERIC Educational Resources Information Center
Ranaweera, Sisika Priyani Nelum; Montplaisir, Lisa Marie
2010-01-01
The purpose of this study was to explore students' knowledge and learning of the human nervous system (HNS) in an introductory undergraduate Human Anatomy and Physiology course. Classroom observations, demographic data, a preinstructional unit test with drawings, and a postinstructional unit test with drawings were used to identify students'…
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate reported as carbon, kg/hr... unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii), the percentage...
40 CFR 63.865 - Performance test requirements and test methods.
Code of Federal Regulations, 2012 CFR
2012-07-01
... follows: ER18FE03.012 Where: ERSCCU = THC emission rate reported as carbon from each semichemical combustion unit, kg/Mg (lb/ton) of black liquor solids fired; THCmeas = Measured THC mass emission rate... semichemical combustion unit has selected the percentage reduction standards for THC, under § 63.862(c)(2)(ii...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are...
Engineering Encounters: Sailing into the Digital Era
ERIC Educational Resources Information Center
Bellavance, Janet; Truchon, Amy
2015-01-01
This article describes how Janet Bellavance teamed with technology integration specialist, Amy Truchon to incorporate iPads into her Engineering is Elementary (EiE) unit--a curriculum that engages elementary students in engineering simple technologies. In an EiE unit, students design, test, and then, based on test results, improve their design,…
21 CFR 640.15 - Segments for testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.15 Segments for testing... provided with each unit of Whole Blood or Red Blood Cells when issued or reissued. (b) Before they are... cells. (c) All segments accompanying a unit of Red Blood Cells shall be filled at the time the blood is...
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, James T.; Sobolik, Steven R.; Lee, Moo Y.
The study described in this report involves heated and unheated pressurized slot testing to determine thermo-mechanical properties of the Tptpll (Tertiary, Paintbrush, Topopah Spring Tuff Formation, crystal poor, lower lithophysal) and Tptpul (upper lithophysal) lithostratigraphic units at Yucca Mountain, Nevada. A large volume fraction of the proposed repository at Yucca Mountain may reside in the Tptpll lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters, making a field program an effective method of measuring bulk thermal-mechanical rock properties (thermal expansion, rock mass modulus, compressive strength, time-dependent deformation) over a range ofmore » temperature and rock conditions. The field tests outlined in this report provide data for the determination of thermo-mechanical properties of this unit. Rock-mass response data collected during this field test will reduce the uncertainty in key thermal-mechanical modeling parameters (rock-mass modulus, strength and thermal expansion) for the Tptpll lithostratigraphic unit, and provide a basis for understanding thermal-mechanical behavior of this unit. The measurements will be used to evaluate numerical models of the thermal-mechanical response of the repository. These numerical models are then used to predict pre- and post-closure repository response. ACKNOWLEDGEMENTS The authors would like to thank David Bronowski, Ronnie Taylor, Ray E. Finley, Cliff Howard, Michael Schuhen (all SNL) and Fred Homuth (LANL) for their work in the planning and implementation of the tests described in this report. This is a reprint of SAND2004-2703, which was originally printed in July 2004. At that time, it was printed for a restricted audience. It has now been approved for unlimited release.« less
Bergeron, V; Reboux, G; Poirot, J L; Laudinet, N
2007-10-01
To evaluate the performance of a new mobile air-treatment unit that uses nonthermal-plasma reactors for lowering the airborne bioburden in critical hospital environments and reducing the risk of nosocomial infection due to opportunistic airborne pathogens, such as Aspergillus fumigatus. Tests were conducted in 2 different high-risk hospital areas: an operating room under simulated conditions and rooms hosting patients in a pediatric hematology ward. Operating room testing provided performance evaluations of removal rates for airborne contamination (ie, particles larger than 0.5 microm) and overall lowering of the airborne bioburden (ie, colony-forming units of total mesophilic flora and fungal flora per cubic meter of air). In the hematology service, opportunistic and nonpathogenic airborne fungal levels in a patient's room equipped with an air-treatment unit were compared to those in a control room. In an operating room with a volume of 118 m(3), the time required to lower the concentration of airborne particles larger than 0.5 microm by 90% was decreased from 12 minutes with the existing high-efficiency particulate air filtration system to less than 2 minutes with the units tested, with a 2-log decrease in the steady-state levels of such particles (P<.01). Concurrently, total airborne mesophilic flora concentrations dropped by a factor of 2, and the concentrations of fungal species were reduced to undetectable levels (P<.01). The 12-day test period in the hematology ward revealed a significant reduction in airborne fungus levels (P<.01), with average reductions of 75% for opportunistic species and 82% for nonpathogenic species. Our data indicate that the mobile, nonthermal-plasma air treatment unit tested in this study can rapidly reduce the levels of airborne particles and significantly lower the airborne bioburden in high-risk hospital environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Tengfang
2006-10-20
Lawrence Berkeley National Laboratory (LBNL) is now finalizing the Phase 2 Research and Demonstration Project on characterizing 2-foot x 4-foot (61-cm x 122-cm) fan-filter units in the market using the first-ever standard laboratory test method developed at LBNL.[1][2][3] Fan-filter units deliver re-circulated air and provide particle filtration control for clean environments. Much of the energy in cleanrooms (and minienvironments) is consumed by 2-foot x 4-foot (61-cm x 122-cm) or 4-foot x 4-foot (122-cm x 122-cm) fan-filter units that are typically located in the ceiling (25-100% coverage) of cleanroom controlled environments. Thanks to funding support by the California Energy Commission's Industrialmore » Program of the Public Interest Energy Research (PIER) Program, and significant participation from manufacturers and users of fan-filter units from around the world, LBNL has developed and performed a series of standard laboratory tests and reporting on a variety of 2-foot x 4-foot (61-cm x 122-cm) fan-filter units (FFUs). Standard laboratory testing reports have been completed and reported back to anonymous individual participants in this project. To date, such reports on standard testing of FFU performance have provided rigorous and useful data for suppliers and end users to better understand, and more importantly, to quantitatively characterize performance of FFU products under a variety of operating conditions.[1] In the course of the project, the standard laboratory method previously developed at LBNL has been under continuous evaluation and update.[2][3] Based upon the updated standard, it becomes feasible for users and suppliers to characterize and evaluate energy performance of FFUs in a consistent way.« less
NASA Technical Reports Server (NTRS)
Dobler, F. X.
1978-01-01
A 500 to 2100 watt power output Mini-Brayton Rotating Unit (Mini-BRU)was analyzed, designed, fabricated and tested. Performance and test data for the various components is included. Components tested include the 2.12 in. diameter compressor, the 2.86 in. diameter turbine, the Rice alternator and the cantilevered foil-type journal and thrust bearings. Also included are results on the fabrication of a C-103 turbine plenum/nozzle assembly and on offgassing of the organic materials in the alternator stator.
Large area sheet task: Advanced Dendritic Web Growth Development
NASA Technical Reports Server (NTRS)
Duncan, C. S.; Seidensticker, R. G.; Mchugh, J. P.; Hopkins, R. H.; Meier, D.; Schruben, J.
1981-01-01
A melt level control system was implemented to provide stepless silicon feed rates from zero to rates exactly matching the silicon consumed during web growth. Bench tests of the unit were successfully completed and the system mounted in a web furnace for operational verification. Tests of long term temperature drift correction techniques were made; web width monitoring seems most appropriate for feedback purposes. A system to program the initiation of the web growth cycle was successfully tested. A low cost temperature controller was tested which functions as well as units four times as expensive.
Mountain Plains Learning Experience Guide: Automotive Repair. Course: Emission Systems.
ERIC Educational Resources Information Center
Schramm, C.; Osland, Walt
One of twelve individualized courses included in an automotive repair curriculum, this course covers the theory, testing, and servicing of automotive emission control systems. The course is comprised of one unit, Fundamentals of Emission Systems. The unit begins with a Unit Learning Experience Guide that gives directions for unit completion. The…
Unit Mastery Learning in an Introductory Geography Course
ERIC Educational Resources Information Center
Healy, John R.; Stephenson, Larry K.
1975-01-01
The unit mastery learning system is a method of individualized, self-paced learning which, through repeatable testing, enables students to attain a mastery of the content of one unit before proceeding to the next in the program. This article describes the unit mastery learning system and its application in an introductory geography course at Hilo…
Halogen and LED light curing of composite: temperature increase and Knoop hardness.
Schneider, L F; Consani, S; Correr-Sobrinho, L; Correr, A B; Sinhoreti, M A
2006-03-01
This study assessed the Knoop hardness and temperature increase provided by three light curing units when using (1) the manufacturers' recommended times of photo-activation and (2) standardizing total energy density. One halogen--XL2500 (3M/ESPE)--and two light-emitting diode (LED) curing units--Freelight (3M/ESPE) and Ultrablue IS (DMC)--were used. A type-K thermocouple registered the temperature change produced by the composite photo-activation in a mold. Twenty-four hours after the photo-activation procedures, the composite specimens were submitted to a hardness test. Both temperature increase and hardness data were submitted to ANOVA and Tukey's test (5% significance). Using the first set of photo-activation conditions, the halogen unit produced a statistically higher temperature increase than did both LED units, and the Freelight LED resulted in a lower hardness than did the other curing units. When applying the second set of photo-activation conditions, the two LED units produced statistically greater temperature increase than did the halogen unit, whereas there were no statistical differences in hardness among the curing units.
Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?
Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J
2015-11-01
We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, G.; Nelson, S.; Cooperrider, N.K.
1982-02-11
This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Jeffrey J.
2010-04-30
The Wabash gasification facility, owned and operated by sgSolutions LLC, is one of the largest single train solid fuel gasification facilities in the world capable of transforming 2,000 tons per day of petroleum coke or 2,600 tons per day of bituminous coal into synthetic gas for electrical power generation. The Wabash plant utilizes Phillips66 proprietary E-Gas (TM) Gasification Process to convert solid fuels such as petroleum coke or coal into synthetic gas that is fed to a combined cycle combustion turbine power generation facility. During plant startup in 1995, reliability issues were realized in the gas filtration portion of themore » gasification process. To address these issues, a slipstream test unit was constructed at the Wabash facility to test various filter designs, materials and process conditions for potential reliability improvement. The char filtration slipstream unit provided a way of testing new materials, maintenance procedures, and process changes without the risk of stopping commercial production in the facility. It also greatly reduced maintenance expenditures associated with full scale testing in the commercial plant. This char filtration slipstream unit was installed with assistance from the United States Department of Energy (built under DOE Contract No. DE-FC26-97FT34158) and began initial testing in November of 1997. It has proven to be extremely beneficial in the advancement of the E-Gas (TM) char removal technology by accurately predicting filter behavior and potential failure mechanisms that would occur in the commercial process. After completing four (4) years of testing various filter types and configurations on numerous gasification feed stocks, a decision was made to investigate the economic and reliability effects of using a particulate removal gas cyclone upstream of the current gas filtration unit. A paper study had indicated that there was a real potential to lower both installed capital and operating costs by implementing a char cyclonefiltration hybrid unit in the E-Gas (TM) gasification process. These reductions would help to keep the E-Gas (TM) technology competitive among other coal-fired power generation technologies. The Wabash combined cyclone and gas filtration slipstream test program was developed to provide design information, equipment specification and process control parameters of a hybrid cyclone and candle filter particulate removal system in the E-Gas (TM) gasification process that would provide the optimum performance and reliability for future commercial use. The test program objectives were as follows: 1. Evaluate the use of various cyclone materials of construction; 2. Establish the optimal cyclone efficiency that provides stable long term gas filter operation; 3. Determine the particle size distribution of the char separated by both the cyclone and candle filters. This will provide insight into cyclone efficiency and potential future plant design; 4. Determine the optimum filter media size requirements for the cyclone-filtration hybrid unit; 5. Determine the appropriate char transfer rates for both the cyclone and filtration portions of the hybrid unit; 6. Develop operating procedures for the cyclone-filtration hybrid unit; and, 7. Compare the installed capital cost of a scaled-up commercial cyclone-filtration hybrid unit to the current gas filtration design without a cyclone unit, such as currently exists at the Wabash facility.« less
The Damper Spring Unit of the Sentinel 1 Solar Array
NASA Technical Reports Server (NTRS)
Doejaaren, Frans; Ellenbroek, Marcel
2012-01-01
The Damper Spring Unit (DSU, see Figure 1) has been designed to provide the damping required to control the deployment speed of the spring driven solar array deployment in an ARA Mk3 or FRED based Solar Array in situations where the standard application of a damper at the root-hinge is not feasible. The unit consists of four major parts: a main bracket, an eddy current damper, a spring unit, an actuation pulley which is coupled via Kevlar cables to a synchro-pulley of a hinge. The damper slows down the deployment speed and prevents deployment shocks at deployment completion. The spring unit includes 4 springs which overcome the resistances of the damper and the specific DSU control cable loop. This means it can be added to any spring driven deployment system without major modifications of that system. Engineering models of the Sentinel 1 solar array wing have been built to identify the deployment behavior, and to help to determine the optimal pulley ratios of the solar array and to finalize the DSU design. During the functional tests, the behavior proved to be very sensitive for the alignment of the DSU. This was therefore monitored carefully during the qualification program, especially prior to the TV cold testing. During TV "Cold" testing the measured retarding torque exceeded the max. required value: 284 N-mm versus the required 247 N-mm. Although this requirement was not met, the torque balance analysis shows that the 284 N-mm can be accepted, because the spring unit can provide 1.5 times more torque than required. Some functional tests of the DSU have been performed without the eddy current damper attached. It provided input data for the ADAMS solar array wing model. Simulation of the Sentinel-1 deployment (including DSU) in ADAMS allowed the actual wing deployment tests to be limited in both complexity and number of tests. The DSU for the Sentinel-1 solar array was successfully qualified and the flight models are in production.
Enhancing Carbon Reactivity in Mercury Control in Lignite-Fired Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chad Wocken; Michael Holmes; John Pavlish
2008-06-30
This project was awarded through the U.S. Department of Energy (DOE) National Energy Technology Laboratory Program Solicitation DE-PS26-03NT41718-01. The Energy & Environmental Research Center (EERC) led a consortium-based effort to resolve mercury (Hg) control issues facing the lignite industry. The EERC team-the Electric Power Research Institute (EPRI); the URS Corporation; the Babcock & Wilcox Company; ADA-ES; Apogee; Basin Electric Power Cooperative; Otter Tail Power Company; Great River Energy; Texas Utilities; Montana-Dakota Utilities Co.; Minnkota Power Cooperative, Inc.; BNI Coal Ltd.; Dakota Westmoreland Corporation; the North American Coal Corporation; SaskPower; and the North Dakota Industrial Commission-demonstrated technologies that substantially enhanced themore » effectiveness of carbon sorbents to remove Hg from western fuel combustion gases and achieve a high level ({ge} 55% Hg removal) of cost-effective control. The results of this effort are applicable to virtually all utilities burning lignite and subbituminous coals in the United States and Canada. The enhancement processes were previously proven in pilot-scale and limited full-scale tests. Additional optimization testing continues on these enhancements. These four units included three lignite-fired units: Leland Olds Station Unit 1 (LOS1) and Stanton Station Unit 10 (SS10) near Stanton and Antelope Valley Station Unit 1 (AVS1) near Beulah and a subbituminous Powder River Basin (PRB)-fired unit: Stanton Station Unit 1 (SS1). This project was one of three conducted by the consortium under the DOE mercury program to systematically test Hg control technologies available for utilities burning lignite. The overall objective of the three projects was to field-test and verify options that may be applied cost-effectively by the lignite industry to reduce Hg emissions. The EERC, URS, and other team members tested sorbent injection technologies for plants equipped with electrostatic precipitators (ESPs) and spray dryer absorbers combined with fabric filters (SDAs-FFs). The work focused on technology commercialization by involving industry and emphasizing the communication of results to vendors and utilities throughout the project.« less
Layton, J Bradley; Kim, Yoonsang; Alexander, G Caleb; Emery, Sherry L
2017-03-21
Testosterone initiation increased substantially in the United States from 2000 to 2013, especially among men without clear indications. Direct-to-consumer advertising (DTCA) also increased during this time. To investigate associations between televised DTCA and testosterone testing and initiation in the United States. Ecologic study conducted in designated market areas (DMAs) in the United States. Monthly testosterone advertising ratings were linked to DMA-level testosterone use data from 2009-2013 derived from commercial insurance claims. Associations between DTCA and testosterone testing, initiation, and initiation without recent baseline tests were estimated using Poisson generalized estimating equations. Monthly Nielsen ratings for testosterone DTCA in the 75 largest DMAs. (1) Rates of new serum testosterone testing; (2) rates of testosterone initiation (in-office injection, surgical implant, or pharmacy dispensing) for all testosterone products combined and for specific brands; and (3) rates of testosterone initiation without recent serum testosterone testing. Of 17 228 599 commercially insured men in the 75 DMAs, 1 007 990 (mean age, 49.6 [SD, 11.5] years) had new serum testosterone tests and 283 317 (mean age, 51.8 [SD, 11.3] years) initiated testosterone treatment. Advertising intensity varied by geographic region and time, with the highest intensity seen in the southeastern United States and with months ranging from no ad exposures to a mean of 13.6 exposures per household. Nonbranded advertisements were common prior to 2012, with branded advertisements becoming more common during and after 2012. Each household advertisement exposure was associated with a monthly increase in rates of new testosterone testing (rate ratio [RR], 1.006; 95% CI, 1.004-1.008), initiation (RR, 1.007; 95% CI, 1.004-1.010), and initiation without a recent test (RR, 1.008; 95% CI, 1.002-1.013). Mean absolute rate increases were 0.14 tests (95% CI, 0.09-0.19), 0.05 new initiations (95% CI, 0.03-0.08), and 0.02 initiations without a recent test (95% CI, 0.01-0.03) per 10 000 men for each monthly ad exposure over the entire period. Among US men residing in the 75 designated market areas, regional exposure to televised direct-to-consumer advertising was associated with greater testosterone testing, new initiation, and initiation without recent testing.
Prevalence of syphilis in pregnancy and prenatal syphilis testing in Brazil: birth in Brazil study.
Domingues, Rosa Maria Soares Madeira; Szwarcwald, Celia Landmann; Souza Junior, Paulo Roberto Borges; Leal, Maria do Carmo
2014-10-01
Determine the coverage rate of syphilis testing during prenatal care and the prevalence of syphilis in pregnant women in Brazil. This is a national hospital-based cohort study conducted in Brazil with 23,894 postpartum women between 2011 and 2012. Data were obtained using interviews with postpartum women, hospital records, and prenatal care cards. All postpartum women with a reactive serological test result recorded in the prenatal care card or syphilis diagnosis during hospitalization for childbirth were considered cases of syphilis in pregnancy. The Chi-square test was used for determining the disease prevalence and testing coverage rate by region of residence, self-reported skin color, maternal age, and type of prenatal and child delivery care units. Prenatal care covered 98.7% postpartum women. Syphilis testing coverage rate was 89.1% (one test) and 41.2% (two tests), and syphilis prevalence in pregnancy was 1.02% (95% CI 0.84; 1.25). A lower prenatal coverage rate was observed among women in the North region, indigenous women, those with less education, and those who received prenatal care in public health care units. A lower testing coverage rate was observed among residents in the North, Northeast, and Midwest regions, among younger and non-white skin-color women, among those with lower education, and those who received prenatal care in public health care units. An increased prevalence of syphilis was observed among women with < 8 years of education (1.74%), who self-reported as black (1.8%) or mixed (1.2%), those who did not receive prenatal care (2.5%), and those attending public (1.37%) or mixed (0.93%) health care units. The estimated prevalence of syphilis in pregnancy was similar to that reported in the last sentinel surveillance study conducted in 2006. There was an improvement in prenatal care and testing coverage rate, and the goals suggested by the World Health Organization were achieved in two regions. Regional and social inequalities in access to health care units, coupled with other gaps in health assistance, have led to the persistence of congenital syphilis as a major public health problem in Brazil.
Prevalence of syphilis in pregnancy and prenatal syphilis testing in Brazil: Birth in Brazil study
Domingues, Rosa Maria Soares Madeira; Szwarcwald, Celia Landmann; Souza, Paulo Roberto Borges; Leal, Maria do Carmo
2014-01-01
OBJECTIVE Determine the coverage rate of syphilis testing during prenatal care and the prevalence of syphilis in pregnant women in Brazil. METHODS This is a national hospital-based cohort study conducted in Brazil with 23,894 postpartum women between 2011 and 2012. Data were obtained using interviews with postpartum women, hospital records, and prenatal care cards. All postpartum women with a reactive serological test result recorded in the prenatal care card or syphilis diagnosis during hospitalization for childbirth were considered cases of syphilis in pregnancy. The Chi-square test was used for determining the disease prevalence and testing coverage rate by region of residence, self-reported skin color, maternal age, and type of prenatal and child delivery care units. RESULTS Prenatal care covered 98.7% postpartum women. Syphilis testing coverage rate was 89.1% (one test) and 41.2% (two tests), and syphilis prevalence in pregnancy was 1.02% (95%CI 0.84;1.25). A lower prenatal coverage rate was observed among women in the North region, indigenous women, those with less education, and those who received prenatal care in public health care units. A lower testing coverage rate was observed among residents in the North, Northeast, and Midwest regions, among younger and non-white skin-color women, among those with lower education, and those who received prenatal care in public health care units. An increased prevalence of syphilis was observed among women with < 8 years of education (1.74%), who self-reported as black (1.8%) or mixed (1.2%), those who did not receive prenatal care (2.5%), and those attending public (1.37%) or mixed (0.93%) health care units. CONCLUSIONS The estimated prevalence of syphilis in pregnancy was similar to that reported in the last sentinel surveillance study conducted in 2006. There was an improvement in prenatal care and testing coverage rate, and the goals suggested by the World Health Organization were achieved in two regions. Regional and social inequalities in access to health care units, coupled with other gaps in health assistance, have led to the persistence of congenital syphilis as a major public health problem in Brazil. PMID:25372167
Souvignier, Elmar; Kronenberger, Julia
2007-12-01
There is much support for using cooperative methods, since important instructional aspects, such as elaboration of new information, can easily be realized by methods like 'jigsaw'. However, the impact of providing students with additional help like a questioning training and potential limitations of the method concerning the (minimum) age of the students have rarely been investigated. The study investigated the effects of cooperative methods at elementary school level. Three conditions of instruction were compared: jigsaw, jigsaw with a supplementary questioning training and teacher-guided instruction. Nine third grade classes from three schools with 208 students participated in the study. In each school, all the three instructional conditions were realized in three different classes. All classes studied three units on geometry and one unit on astronomy using the assigned instructional method. Each learning unit comprised six lessons. For each unit, an achievement test was administered as pre-test, post-test and delayed test. In the math units, no differences between the three conditions could be detected. In the astronomy unit, students benefited more from teacher-guided instruction. Differential analyses revealed that 'experts' learned more than students in teacher-guided instruction, whereas 'novices' were outperformed by the students in the control classes. Even third graders used the jigsaw method with satisfactory learning results. The modest impact of the questioning training and the low learning gains of the cooperative classes in the astronomy unit as well as high discrepancies between learning outcomes of experts and novices show that explicit instruction of explaining skills in combination with well-structured material are key issues in using the jigsaw method with younger students.
Choi, Eun Ha; Kim, Eun-Kyung; Kim, Pil Bong
2018-03-31
EDUCATIONAL LEADERSHIP OF NURSING UNIT MANAGERS ON TEAM EFFECTIVENESS: Mediating Effects of Organizational Communication Satisfaction. This study identifies the effects of the educational leadership of nursing unit managers on team effectiveness and the mediating effects of organizational communication satisfaction; it highlights the importance of educational leadership and organizational communication and provides the data needed to enhance the education capacity of managers. The participants were 216 nursing unit managers of staff nurses at a tertiary hospital located in C Region, South Korea, and nurses who had worked for more than six months at the same hospital. This study was conducted using questionnaires on educational leadership, team effectiveness, and organizational communication satisfaction. Data analysis was performed with a t-test, ANOVA, Scheffé, Pearson's correlation coefficient, and simple and multiple regression analyses using SPSS version 23.0. Mediation analysis was tested using Baron and Kenny's regression analysis and a Sobel test. The mean score for the educational leadership of nursing unit managers was 3.74(±0.68); for organizational communication satisfaction, 3.14(±0.51); and for team effectiveness, 3.52(±0.49). Educational leadership was significantly positively correlated with team effectiveness and organizational communication satisfaction. Organizational communication satisfaction demonstrated a complete mediating effect on the relationship between educational leadership and team effectiveness (β=.61, p<.001) and was significant (Sobel test; Z=7.40, p<.001). The results indicate that the educational leadership of nursing unit managers increases communication satisfaction among nurses; this supports the idea that educational leadership can contribute to team effectiveness. This suggests that the educational leadership and communication capacity of nursing unit managers must be improved to enhance the performance of nursing organizations. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Saigo, Barbara Woodworth
The researcher collaborated with four high school biology teachers who had been involved for 2-1/2 years in a constructivism-based professional development experience that emphasized teaching for conceptual change and using classroom-based inquiry as a basis for making instructional decisions. The researcher and teachers designed a five-day instructional unit on biosystematics using two contrasting approaches, comprising the treatment variable. The "traditional" unit emphasized lecture, written materials, and some laboratory activities. The "constructivist" unit emphasized a specific, inquiry-based, conceptual change strategy and collaborative learning. The study used a quasi-experimental, factorial design to explore impact of instructional approach (the treatment variable) on student performance (the dependent variable) on repeated measures (three) of a biology concept test. Additional independent variables considered were gender, cumulative GPA, and the section in which students were enrolled. Scores on the biology concept test were compiled for the 3 constructivist sections (N = 44) and the 3 traditional sections (N = 42). Analysis of Covariance (ANCOVA) was applied. The main findings in regard to the primary research question were that instructional approach did not have a significant relationship to immediate post test scores or gain, but that one month after instruction students in the constructivist group demonstrated less loss of gain than those in the traditional group; i.e., their longer-term retention was greater. Also, GPA*instructional approach effects were detected for post-post-test gain. GPA and gender were significantly associated with pre-test, post-test, and post-post scores; however, in terms of change (gain) from pre-test to post-test and pre-test to post-post-test, GPA and gender were not significant effects. Section was a significant effect for all three tests, in terms of both score and gain. Gender*section effects were detected for post-test gain and post-post-test scores.
Portable light source unit for simulating fires having an adjustable aperture
NASA Technical Reports Server (NTRS)
Youngquist, Robert C. (Inventor); Moerk, John S. (Inventor); Strobel, James P. (Inventor)
1997-01-01
A portable, hand held light source unit is employed to check operation of fire detectors, such as hydrogen fire detectors. The unit emits radiation in a narrow band of wavelengths which are generated by the type of fire to be tested, but not by other light sources such as the sun or incandescent lamps. The unit can test fire detectors at different distances, and of different sensitivities. The intensity of the radiation emitted by the unit is adjustable for this purpose by means of a rotatable disk having a plurality of different sized apertures for selective placement between the light source and an output lens. The disk can also be rotated to a calibration position which causes a microprocessor circuit in the unit to initiate a calibration procedure. During this procedure, the lamp intensity is measured by a photodetector contained within the unit, and the microprocessor adjusts the lamp current to insure that its intensity remains within a preset range of values. A green and a red LED are mounted on the unit which indicate to an operator whether the calibration is successful, as well as the condition of the unit's battery power supply.
NASA Technical Reports Server (NTRS)
Valdez, A.
1999-01-01
This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Electromagnetic Interference (EMI), Electromagnetic Susceptibility, and Electromagnetic Compatibility (EMC) qualification test for the Meteorological Satellite (METSAT) and the Meteorological Operation Platform (METOP) projects. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/5D. This document describes the EMI/EMC test performed by Aerojet and it is presented in the following manner: Section-1 contains introductory material and a brief summary of the test results. Section 2 contains more detailed descriptions of the test plan, test procedure, and test results for each type of EMI/EMC test conducted. Section 3 contains supplementary information that includes test data sheets, plots, and calculations collected during the qualification testing.
NASA Shuttle Logistics Depot (NSLD) - The application of ATE
NASA Technical Reports Server (NTRS)
Simpkins, Lorenz G.; Jenkins, Henry C.; Mauceri, A. Jack
1990-01-01
The concept of the NASA Shuttle Logistics Depot (NSLD) developed for the Space Shuttle Orbiter Program is described. The function of the NSLD at Cape Canaveral is to perform the acceptance and diagnostic testing of the Shuttle's space-rated line-replaceable units and shop-replaceable units (SRUs). The NSLD includes a comprehensive electronic automatic test station, program development stations, and assorted manufacturing support equipment (including thermal and vibration test equipment, special test equipment, and a card SRU test system). The depot activities also include the establishment of the functions for manufacturing of mechanical parts, soldering, welding, painting, clean room operation, procurement, and subcontract management.
CSI computer system/remote interface unit acceptance test results
NASA Technical Reports Server (NTRS)
Sparks, Dean W., Jr.
1992-01-01
The validation tests conducted on the Control/Structures Interaction (CSI) Computer System (CCS)/Remote Interface Unit (RIU) is discussed. The CCS/RIU consists of a commercially available, Langley Research Center (LaRC) programmed, space flight qualified computer and a flight data acquisition and filtering computer, developed at LaRC. The tests were performed in the Space Structures Research Laboratory (SSRL) and included open loop excitation, closed loop control, safing, RIU digital filtering, and RIU stand alone testing with the CSI Evolutionary Model (CEM) Phase-0 testbed. The test results indicated that the CCS/RIU system is comparable to ground based systems in performing real-time control-structure experiments.
Design ATE systems for complex assemblies
NASA Astrophysics Data System (ADS)
Napier, R. S.; Flammer, G. H.; Moser, S. A.
1983-06-01
The use of ATE systems in radio specification testing can reduce the test time by approximately 90 to 95 percent. What is more, the test station does not require a highly trained operator. Since the system controller has full power over all the measurements, human errors are not introduced into the readings. The controller is immune to any need to increase output by allowing marginal units to pass through the system. In addition, the software compensates for predictable, repeatable system errors, for example, cabling losses, which are an inherent part of the test setup. With no variation in test procedures from unit to unit, there is a constant repeatability factor. Preparing the software, however, usually entails considerable expense. It is pointed out that many of the problems associated with ATE system software can be avoided with the use of a software-intensive, or computer-intensive, system organization. Its goal is to minimize the user's need for software development, thereby saving time and money.
NASA Astrophysics Data System (ADS)
Svatos, Adam Ladislav
This thesis describes the author's contributions to three separate projects. The bus of the NORSAT-2 satellite was developed by the Space Flight Laboratory (SFL) for the Norwegian Space Centre (NSC) and Space Norway. The author's contributions to the mission were performing unit tests for the components of all the spacecraft subsystems as well as designing and assembling the flatsat from flight spares. Gedex's Vector Gravimeter for Asteroids (VEGA) is an accelerometer for spacecraft. The author's contributions to this payload were modifying the instrument computer board schematic, designing the printed circuit board, developing and applying test software, and performing thermal acceptance testing of two instrument computer boards. The SFL's cylindrical Hall effect thruster combines the cylindrical configuration for a Hall thruster and uses permanent magnets to achieve miniaturization and low power consumption, respectively. The author's contributions were to design, build, and test an engineering model power processing unit.
Assessment of microwave-based clinical waste decontamination unit.
Hoffman, P N; Hanley, M J
1994-12-01
A clinical waste decontamination unit that used microwave-generated heat was assessed for operator safety and efficacy. Tests with loads artificially contaminated with aerosol-forming particles showed that no particles were detected outside the machine provided the seals and covers were correctly seated. Thermometric measurement of a self-generated steam decontamination cycle was used to determine the parameters needed to ensure heat disinfection of the waste reception hopper, prior to entry for maintenance or repair. Bacterial and thermometric test pieces were passed through the machine within a full load of clinical waste. These test pieces, designed to represent a worst case situation, were enclosed in aluminium foil to shield them from direct microwave energy. None of the 100 bacterial test pieces yielded growth on culture and all 100 thermal test pieces achieved temperatures in excess of 99 degrees C during their passage through the decontamination unit. It was concluded that this method may be used to render safe the bulk of of ward-generated clinical waste.
NASA Astrophysics Data System (ADS)
Marulcu, Ismail; Barnett, Michael
2016-01-01
Background: Elementary Science Education is struggling with multiple challenges. National and State test results confirm the need for deeper understanding in elementary science education. Moreover, national policy statements and researchers call for increased exposure to engineering and technology in elementary science education. The basic motivation of this study is to suggest a solution to both improving elementary science education and increasing exposure to engineering and technology in it. Purpose/Hypothesis: This mixed-method study examined the impact of an engineering design-based curriculum compared to an inquiry-based curriculum on fifth graders' content learning of simple machines. We hypothesize that the LEGO-engineering design unit is as successful as the inquiry-based unit in terms of students' science content learning of simple machines. Design/Method: We used a mixed-methods approach to investigate our research questions; we compared the control and the experimental groups' scores from the tests and interviews by using Analysis of Covariance (ANCOVA) and compared each group's pre- and post-scores by using paired t-tests. Results: Our findings from the paired t-tests show that both the experimental and comparison groups significantly improved their scores from the pre-test to post-test on the multiple-choice, open-ended, and interview items. Moreover, ANCOVA results show that students in the experimental group, who learned simple machines with the design-based unit, performed significantly better on the interview questions. Conclusions: Our analyses revealed that the design-based Design a people mover: Simple machines unit was, if not better, as successful as the inquiry-based FOSS Levers and pulleys unit in terms of students' science content learning.
Getting to Zero Yield: The Evolution of the U.S. Position on the CTBT
NASA Astrophysics Data System (ADS)
Zimmerman, Peter D.
1998-03-01
In 1994 the United States favored a Comprehensive Test Ban Treaty (CTBT) which permitted tiny "hydronuclear" experiments with a nuclear energy release of four pounds or less. Other nuclear powers supported yield limits as high as large fractions of a kiloton, while most non-nuclear nations participating in the discussions at the United Nations Conference on Disarmament wanted to prohibit all nuclear explosions -- some even favoring an end to computer simulations. On the other hand, China wished an exception to permit high yield "peaceful" nuclear explosions. For the United States to adopt a new position favoring a "true zero" several pieces had to fall into place: 1) The President had to be assured that the U.S. could preserve the safety and reliability of the enduring stockpile without yield testing; 2) the U.S. needed to be sure that the marginal utility of zero-yield experiments was at least as great for this country as for any other; 3) that tests with any nuclear yield might have more marginal utility for nuclear proliferators than for the United States, thus marginally eroding this country's position; 4) the United States required a treaty which would permit maintenance of the capacity to return to testing should a national emergency requiring a nuclear test arise; and 5) all of the five nuclear weapons states had to realize that only a true-zero CTBT would have the desired political effects. This paper will outline the physics near zero yield and show why President Clinton was persuaded by arguments from many viewpoints to endorse a true test ban in August, 1996 and to sign the CTBT in September, 1997.
Unit: Minerals and Crystals, First Trial Materials, Inspection Set.
ERIC Educational Resources Information Center
Australian Science Education Project, Toorak, Victoria.
This unit, one of a series being developed for Australian secondary school science courses, consists of a teacher's guide, two student booklets, a test booklet, and a student workbook which also contains answers to questions raised in the student booklets, and a answer sheet containing comments on the answers to the questions in the test booklet.…
ERIC Educational Resources Information Center
Gohara, Sabry; Shapiro, Joseph I.; Jacob, Adam N.; Khuder, Sadik A.; Gandy, Robyn A.; Metting, Patricia J.; Gold, Jeffrey; Kleshinski, James; and James Kleshinski
2011-01-01
The purpose of this study was to evaluate whether models based on pre-admission testing, including performance on the Medical College Admission Test (MCAT), performance on required courses in the medical school curriculum, or a combination of both could accurately predict performance of medical students on the United States Medical Licensing…
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units Testing and Initial... liquid oil-fired unit, and you use quarterly stack testing for HCl and HF plus site-specific parameter monitoring to demonstrate continuous performance, you must also establish a site-specific operating limit, in...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants: Coal- and Oil-Fired Electric Utility Steam Generating Units Testing and Initial... liquid oil-fired unit, and you use quarterly stack testing for HCl and HF plus site-specific parameter monitoring to demonstrate continuous performance, you must also establish a site-specific operating limit, in...
40 CFR 62.15265 - How do I monitor the load of my municipal waste combustion unit?
Code of Federal Regulations, 2013 CFR
2013-07-01
... Mechanical Engineers (ASME PTC 4.1—1964): Test Code for Steam Generating Units, Power Test Code 4.1-1964... of Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (4) Design, construct...
40 CFR 62.15265 - How do I monitor the load of my municipal waste combustion unit?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Mechanical Engineers (ASME PTC 4.1—1964): Test Code for Steam Generating Units, Power Test Code 4.1-1964... of Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (4) Design, construct...
40 CFR 62.15265 - How do I monitor the load of my municipal waste combustion unit?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mechanical Engineers (ASME PTC 4.1—1964): Test Code for Steam Generating Units, Power Test Code 4.1-1964... of Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (4) Design, construct...
40 CFR 62.15265 - How do I monitor the load of my municipal waste combustion unit?
Code of Federal Regulations, 2012 CFR
2012-07-01
... Mechanical Engineers (ASME PTC 4.1—1964): Test Code for Steam Generating Units, Power Test Code 4.1-1964... of Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (4) Design, construct...
40 CFR 62.15265 - How do I monitor the load of my municipal waste combustion unit?
Code of Federal Regulations, 2014 CFR
2014-07-01
... Mechanical Engineers (ASME PTC 4.1—1964): Test Code for Steam Generating Units, Power Test Code 4.1-1964... of Mechanical Engineers, Service Center, 22 Law Drive, Post Office Box 2900, Fairfield, NJ 07007. You....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (4) Design, construct...
Effectiveness of Multipurpose Unit Early Classroom Intervention Program for 4-5-Year-Old Children
ERIC Educational Resources Information Center
Celebioglu Morkoc, Ozlem; Aktan Acar, Ebru
2014-01-01
This research examined the effectiveness of Multipurpose Unit Early Classroom Intervention Program (MUECIP) prepared for 4-5-year-old (48-60 months) children whose development is at risk because of their families' socioeconomic conditions. The research adopted a preliminary test-final test control group trial model. The research participants were…
ERIC Educational Resources Information Center
Wherritt, Irene; Cleary, T. Anne
1990-01-01
Describes the results of a national survey that was conducted to determine the current state of Spanish-language testing for placement and outcome assessments. The survey was undertaken in the United States in the departments of Spanish in B.A.-granting institutions. (Author/VWL)
34 CFR 361.54 - Participation of individuals in cost of services based on financial need.
Code of Federal Regulations, 2010 CFR
2010-07-01
... types of vocational rehabilitation services for which the unit has established a financial needs test... service. (3) The designated State unit may not apply a financial needs test, or require the financial... 34 Education 2 2010-07-01 2010-07-01 false Participation of individuals in cost of services based...
Code of Federal Regulations, 2013 CFR
2013-07-01
... to the vacuum unit to achieve full diaphragm displacement. Seal vacuum source to unit. There shall be no visible loss of diaphragm displacement or drop in vacuum gauge reading after a 15 second observation. Vacuum purge system and diaphragm displacement adjusting screw holes should be temporarily sealed...
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the vacuum unit to achieve full diaphragm displacement. Seal vacuum source to unit. There shall be no visible loss of diaphragm displacement or drop in vacuum gauge reading after a 15 second observation. Vacuum purge system and diaphragm displacement adjusting screw holes should be temporarily sealed...
Code of Federal Regulations, 2012 CFR
2012-07-01
... to the vacuum unit to achieve full diaphragm displacement. Seal vacuum source to unit. There shall be no visible loss of diaphragm displacement or drop in vacuum gauge reading after a 15 second observation. Vacuum purge system and diaphragm displacement adjusting screw holes should be temporarily sealed...
Code of Federal Regulations, 2014 CFR
2014-07-01
... to the vacuum unit to achieve full diaphragm displacement. Seal vacuum source to unit. There shall be no visible loss of diaphragm displacement or drop in vacuum gauge reading after a 15 second observation. Vacuum purge system and diaphragm displacement adjusting screw holes should be temporarily sealed...
Code of Federal Regulations, 2010 CFR
2010-07-01
... to the vacuum unit to achieve full diaphragm displacement. Seal vacuum source to unit. There shall be no visible loss of diaphragm displacement or drop in vacuum gauge reading after a 15 second observation. Vacuum purge system and diaphragm displacement adjusting screw holes should be temporarily sealed...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-04-01
This Closure Report summarizes the corrective actions which were completed at the Corrective Action Sites within Corrective Action Unit 211 Area 15 Farm Waste Sties at the Nevada Test Site. Current site descriptions, observations and identification of wastes removed are included on FFACO Corrective Action Site housekeeping closure verification forms.
Test Review: The Comprehensive Adult Student Assessment System (CASAS) Life Skills Reading Tests
ERIC Educational Resources Information Center
Gorman, David; Ernst, Megan L.
2004-01-01
Lifelong learning has become an important goal of education over the last decade. According to the United States Department of Education (2001), nearly 3 million students over age 17 (excluding those institutionalized) enrolled in adult basic education, adult secondary education, or English as a second language classes in the United States.…
ERIC Educational Resources Information Center
Haile, Getinet Astatike; Nguyen, Anh Ngoc
2008-01-01
We investigate the determinants of high school students' academic attainment in mathematics, reading and science in the United States; focusing particularly on possible differential impacts of ethnicity and family background across the distribution of test scores. Using data from the NELS2000 and employing quantile regression, we find two…
A detailed description of the sequential probability ratio test for 2-IMU FDI
NASA Technical Reports Server (NTRS)
Rich, T. M.
1976-01-01
The sequential probability ratio test (SPRT) for 2-IMU FDI (inertial measuring unit failure detection/isolation) is described. The SPRT is a statistical technique for detecting and isolating soft IMU failures originally developed for the strapdown inertial reference unit. The flowchart of a subroutine incorporating the 2-IMU SPRT is included.
ERIC Educational Resources Information Center
Cimbricz, Sandra K.; McConn, Matthew L.
2015-01-01
This article explores the intersection of new, large-scale standards-based testing, teacher accountability policy, and secondary curriculum and instruction in the United States. Two federally funded consortia--the Smarter Balanced Assessment Consortium and the Partnership for Readiness of College and Careers--prove focal to this paper, as these…
NASA Technical Reports Server (NTRS)
Stoecklin, R. L.
1976-01-01
A total of 114 spoiler units were fabricated in a production shop environment, utilizing three graphite epoxy material systems. Production planning paper was generated for each spoiler unit to completely document each production step of each spoiler unit. The graphite epoxy skins were laid up on production tooling using both mechanical and hand layup techniques. Inspection techniques utilized MRB type assessment in the abscence of quality requirements. Each completed spoiler was subjected to ultrasonic inspection utilizing a multicolor recording system that documented each inspection result. In addition, one static test spoiler was sectioned after the test to examine the adhesive filleting to the honeycomb core. Visual examination of the cured adhesives showed excellent results.
Software for Preprocessing Data from Rocket-Engine Tests
NASA Technical Reports Server (NTRS)
Cheng, Chiu-Fu
2004-01-01
Three computer programs have been written to preprocess digitized outputs of sensors during rocket-engine tests at Stennis Space Center (SSC). The programs apply exclusively to the SSC E test-stand complex and utilize the SSC file format. The programs are the following: Engineering Units Generator (EUGEN) converts sensor-output-measurement data to engineering units. The inputs to EUGEN are raw binary test-data files, which include the voltage data, a list identifying the data channels, and time codes. EUGEN effects conversion by use of a file that contains calibration coefficients for each channel. QUICKLOOK enables immediate viewing of a few selected channels of data, in contradistinction to viewing only after post-test processing (which can take 30 minutes to several hours depending on the number of channels and other test parameters) of data from all channels. QUICKLOOK converts the selected data into a form in which they can be plotted in engineering units by use of Winplot (a free graphing program written by Rick Paris). EUPLOT provides a quick means for looking at data files generated by EUGEN without the necessity of relying on the PV-WAVE based plotting software.
Fiber Optic Cable Feedthrough and Sealing
NASA Technical Reports Server (NTRS)
Fan, Robert J.
1998-01-01
A novel fiberoptic hermetic bulkhead feedthrough has been developed which will offer cryogenic sealing at leak rates of 10(exp -11) cc/sec helium. This feedthrough was developed for NASA in response to needs for a hermetically sealed feedthrough which could withstand a range of temperatures from low cryogenic (-196 C), due to liquid fuels and oxidizers, to high temperatures (+200 C) encountered in the proximity of combustion gasses. The development effort will be reported from conceptual design of single and multi-channel feedthrough units with single interconnection interfaces to units with double-ended interconnection interfaces. Various combinations of fiber/buffers are reported with recommendations based on test results. A comprehensive series of environmental and mechanical tests were performed to evaluate the feedthroughs in adverse conditions. Test results are reported including insertion loss, salt spray, sinusoidal vibration, random vibration, mechanical shock, thermal shock and humidity. A second set of feedthrough units was exposed to 3 different types of radiation. Optical transmittance changes during the tests were monitored and leak rate testing was done after each test. State-of-the-art technology in optical fiber feedthroughs constructed with polycrystalline ceramic is presented.
Software for Preprocessing Data From Rocket-Engine Tests
NASA Technical Reports Server (NTRS)
Cheng, Chiu-Fu
2003-01-01
Three computer programs have been written to preprocess digitized outputs of sensors during rocket-engine tests at Stennis Space Center (SSC). The programs apply exclusively to the SSC E test-stand complex and utilize the SSC file format. The programs are the following: (1) Engineering Units Generator (EUGEN) converts sensor-output-measurement data to engineering units. The inputs to EUGEN are raw binary test-data files, which include the voltage data, a list identifying the data channels, and time codes. EUGEN effects conversion by use of a file that contains calibration coefficients for each channel. (2) QUICKLOOK enables immediate viewing of a few selected channels of data, in contradistinction to viewing only after post-test processing (which can take 30 minutes to several hours depending on the number of channels and other test parameters) of data from all channels. QUICKLOOK converts the selected data into a form in which they can be plotted in engineering units by use of Winplot. (3) EUPLOT provides a quick means for looking at data files generated by EUGEN without the necessity of relying on the PVWAVE based plotting software.
Mobile Food Ordering Application using Android OS Platform
NASA Astrophysics Data System (ADS)
Yosep Ricky, Michael
2014-03-01
The purpose of this research is making an ordering food application based on Android with New Order, Order History, Restaurant Profile, Order Status, Tracking Order, and Setting Profile features. The research method used in this research is water model of System Development Life Cycle (SDLC) method with following phases: requirement definition, analyzing and determining the features needed in developing application and making the detail definition of each features, system and software design, designing the flow of developing application by using storyboard design, user experience design, Unified Modeling Language (UML) design, and database structure design, implementation an unit testing, making database and translating the result of designs to programming language code then doing unit testing, integration and System testing, integrating unit program to one unit system then doing system testing, operation and maintenance, operating the result of system testing and if any changes and reparations needed then the previous phases could be back. The result of this research is an ordering food application based on Android for customer and courier user, and a website for restaurant and admin user. The conclusion of this research is to help customer in making order easily, to give detail information needed by customer, to help restaurant in receiving order, and to help courier while doing delivery.
Effect on moisture permeability of typewriting on unit dose package surfaces.
Rackson, J T; Zellhofer, M J; Birmingham, P H
1984-10-01
The effects of typewriting on labels of two unit dose packages with respect to moisture permeability were examined. Using an electric typewriter, a standard label format was imprinted on two different types of class A unit dose packages: (1) a heat-sealed paper-backed foil and cellofilm strip pouch, and (2) a copolyester and polyethylene multiple-cup blister with a heat-sealed paper-backed foil and cellofilm cover. The labels were typed at various typing-element impact settings. The official USP test for water permeation was then performed on typed packages and untyped control packages. The original untyped packages were confirmed to be USP class A quality. The packages for which successively harder impact settings were used showed a corresponding increase in moisture permeability. This resulted in a lowering of USP package ratings from class A to class B and D, some of which would be unsuitable for use in any unit dose system under current FDA repackaging standards. Typing directly onto the label of a unit dose package before it is sealed will most likely damage the package and possibly make it unfit for use. Pharmacists who must type labels for the unit dose packages studied should use the lowest possible typewriter impact setting and test for damage using the USP moisture-permeation test.
Development and Realization of a Shock Wave Test on Expert Flap Qualification Model
NASA Astrophysics Data System (ADS)
De Fruytier, C.; Dell'Orco, F.; Ullio, R.; Gomiero, F.
2012-07-01
This paper presents the methodology and the results of the shock test campaign conducted by TAS-I and TAS ETCA to qualify the EXPERT Flap in regards of shock wave and acoustic load generated by pyrocord detonation at stages 2/3 separation phase of the EXPERT vehicle. The design concept of the open flap (manufactured by MT AEROSPACE) is a fully integral manufactured, four sided control surface, with an additional stiffening rib and flanges to meet the first eigenfrequency and the allowable deformation requirement with a minimum necessary mass. The objectives were to reproduce equivalent loading at test article level in terms of pulse duration, front pressure, front velocity and acoustic emission. The Thales Alenia Space ETCA pyrotechnic shock test device is usually used to produce high level shocks by performing a shock on a test fixture supporting the unit under test. In this case, the facility has been used to produce a shock wave, with different requested physical characteristics, directed to the unit under test. Different configurations have been tried on a dummy of the unit to test, following an empirical process. This unusual work has lead to the definition of a nominal set- up meeting the requested physical parameters. Two blast sensors have been placed to acquire the pressure around the flap. The distance between the two sensors has allowed estimating the front pressure velocity. Then, several locations have been selected to acquire the acceleration responses on the unit when it was submitted to this environment. Additionally, a “standard” shock test has been performed on this model. The qualification of the flap, in regards of shock environment, has been successfully conducted.
Hermetic Seal Leak Detection Apparatus
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2013-01-01
The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.
Parmer, John; Allen, Leeanna; Walton, Wanda
2017-08-01
: Nurses play a critical role in the diagnosis and treatment of tuberculosis and in the prevention of tuberculosis transmission through infection control practices. To eliminate tuberculosis in the United States, however, an expanded approach to testing and treating people with latent tuberculosis infection must be implemented. Recently, the U.S. Preventive Services Task Force (USPSTF) issued a new recommendation statement on latent tuberculosis infection testing that expands nurses' opportunities to identify at-risk populations for tuberculosis prevention. In combination with newer testing methodologies and shorter treatment regimens, implementation of the USPSTF recommendation has the potential to remove previously existing barriers to screening and treatment of both patients and health care providers. This article provides a general overview of tuberculosis transmission, pathogenesis, and epidemiology; presents preventive care recommendations for targeted testing among high-risk groups; and discusses the USPSTF recommendation's applicability to public health and primary care practice in the United States.
Outpatient substance abuse treatment and HIV prevention: an update.
Pollack, Harold A; D'Aunno, Thomas; Lamar, Barbara
2006-01-01
Testing and counseling, along with community outreach, have been identified as valuable in the prevention of human immunodeficiency virus (HIV) and other blood-borne diseases. This article assesses the extent to which outpatient substance abuse treatment (OSAT) programs provide such services. Longitudinal data for 1988-2000 were analyzed from the National Drug Abuse Treatment System Survey (NDATSS). Random-effects regression was used to examine factors associated with the provision of prevention services. HIV testing, which had became more common between 1990 and 1995, continued to proliferate between 1995 and 2000. The proportion of units that provide HIV testing and counseling increased from 66% to 86%. The proportion of units that provide HIV community outreach increased significantly before 1995 but then slightly decreased from 77% to 73% between 1995 and 2000. In conclusion, HIV testing and counseling widely proliferated in OSAT care. However, OSAT units remain less likely to offer HIV community outreach services.
Technology Solutions Case Study: Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-11-01
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Althoughmore » the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.« less
ERIC Educational Resources Information Center
PLUMPTON, RUSSEL A.
THE METHODS FOR DETERMINING PUPIL READINESS WERE STUDIED TO DEVELOP CRITERIA FOR PUPIL PARTICIPATION IN SIMULATED ENVIRONMENT LEARNING UNITS. THE LEARNING UNITS WERE SUBPROJECTS OF COOPERATIVE RESEARCH PROJECT NUMBER 1948 (ED 003 024). EACH OF THREE UNITS IN THE PROJECT WAS EXAMINED FOR PUPIL READINESS. TEST BATTERIES WERE ASSEMBLED AND…
Behavioral Objectives and Related Test Items for Selected Units in Automotive Mechanics.
ERIC Educational Resources Information Center
Hill, Richard K., Ed.; And Others
This is a catalog of behavioral objectives for Vocational Automotive Mechanics organized by units of instruction as listed in the State curriculum guide. Each unit contains a suggested outline of content, a goal statement, and general and specific objectives. The units taught are: introduction to the automobile; basic hand tools--fasteners and…
1993-08-03
44. Name: Fuze PD M739 United Nations Proper Shipping Name: Fuzes, Detonating United Nations Number: 0408 NSN: 1390-00-574-7705 Drawing Number: 9258605...Physical State: Solid United Nations Packing-group: II Amount Per Container: 8 45. Name: Fuze PD M739 United Nations Proper Shipping Name: Fuzes
Hydrocarbons. Independent Learning Project for Advanced Chemistry (ILPAC). Unit O1.
ERIC Educational Resources Information Center
Inner London Education Authority (England).
This unit on hydrocarbons is one of 10 first year units produced by the Independent Learning Project for Advanced Chemistry (ILPAC). The unit is divided into sections dealing with alkanes, alkenes, alkynes, arenes, and several aspects of the petroleum industry. Two experiments, exercises (with answers), and pre- and post-tests are included.…
Aviation. Fifth Grade. Anchorage School District Elementary Science Program.
ERIC Educational Resources Information Center
Defendorf, Jean, Ed.
This unit of study is designed to teach the science of flight to students in the intermediate grades. Included are a list of materials for the unit, a discussion of the use of process skills, a list of unit objectives, vocabulary, teacher background information, 12 lessons, 5 quizzes, math problems, and a unit test. Lessons are oriented toward…
1999-06-25
Human immunodeficiency virus (HIV) counseling and voluntary testing (CT) programs have been an important part of national HIV prevention efforts since the first HIV antibody tests became available in 1985. In 1995, these programs accounted for approximately 15% of annual HIV antibody testing in the United States, excluding testing for blood donation. CT opportunities are offered to persons at risk for HIV infection at approximately 11,000 sites, including dedicated HIV CT sites, sexually transmitted disease (STD) clinics, drug-treatment centers, hospitals, and prisons. In 39 states, testing can be obtained anonymously, where persons do not have to give their name to get tested. All states provide confidential testing (by name) and have confidentiality laws and regulations to protect this information. This report compares patterns of anonymous and confidential testing in all federally funded CT programs from 1995 through 1997 and documents the importance of both types of testing opportunities.
Blur-resistant perimetric stimuli.
Horner, Douglas G; Dul, Mitchell W; Swanson, William H; Liu, Tiffany; Tran, Irene
2013-05-01
To develop perimetric stimuli that are resistant to the effects of peripheral defocus. One eye each was tested on subjects free of eye disease. Experiment 1 assessed spatial frequency, testing 12 subjects at eccentricities from 2 to 7 degrees using blur levels from 0 to 3 diopters (D) for two (Gabor) stimuli (spatial SD, 0.5 degrees; spatial frequencies, 0.5 and 1.0 cycles per degree [cpd]). Experiment 2 assessed stimulus size, testing 12 subjects at eccentricities from 4 to 7 degrees using blur levels 0 to 6 D for two Gaussians with SD of 0.5 and 0.25 degrees and a 0.5-cpd Gabor with SD of 0.5 degrees. Experiment 3 tested 13 subjects at eccentricities from fixation to 27 degrees using blur levels 0 to 6 D for Gabor stimuli at 56 locations; the spatial frequency ranged from 0.14 to 0.50 cpd with location, and SD was scaled accordingly. In experiment 1, blur by 3 D caused a small decline in log contrast sensitivity for the 0.5-cpd stimulus (mean ± SE, 0.09 ± 0.08 log units) and a larger (t = 7.7, p < 0.0001) decline for the 1.0-cpd stimulus (0.37 ± 0.13 log units). In experiment 2, blur by 6 D caused minimal decline for the larger Gaussian, by 0.17 ± 0.16 log units, and larger (t > 4.5, p < 0.001) declines for the smaller Gaussian (0.33 ± 0.16 log units) and the Gabor (0.36 ± 0.18 log units). In experiment 3, blur by 6 D caused declines by 0.27 ± 0.05 log units for eccentricities from 0 to 10 degrees, by 0.20 ± 0.04 log units for eccentricities from 10 to 20 degrees, and 0.13 ± 0.03 log units for eccentricities from 20 to 27 degrees. Experiments 1 and 2 allowed us to design stimuli for experiment 3 that were resistant to effects of peripheral defocus.
Watanabe, H; Kazama, Re; Asai, T; Kanaya, F; Ishizaki, H; Fukushima, M; Okiji, T
2015-01-01
This study aimed to evaluate the ability of high-intensity light-emitting diode (LED) and other curing units to cure dual-cured resin cement through ceramic material. A halogen curing unit (Jetlite 3000, Morita), a second-generation LED curing unit (Demi, Kerr), and two high-intensity LED curing units (PenCure 2000, Morita; Valo, Ultradent) were tested. Feldspathic ceramic plates (VITABLOCS Mark II, A3; Vita Zahnfabrik) with thicknesses of 1.0, 2.0, and 3.0 mm were prepared. Dual-cured resin cement samples (Clearfil Esthetic Cement, Kuraray Noritake Dental) were irradiated directly or through one of the ceramic plates for different periods (5, 10, 15, or 20 seconds for the high-intensity LED units and 20, 40, 60, or 80 seconds for the others). The Knoop hardness test was used to determine the level of photopolymerization that had been induced in the resin cement. Data were analyzed by one-way analysis of variance and Dunnett's post-hoc test to identify test-control (maximum irradiation without a ceramic plate) differences for each curing unit (p<0.05). For all curing units, the curing conditions had a statistically significant effect on the Knoop hardness numbers (KHNs) of the irradiated cement samples (p<0.001). In general, the KHN decreased with increasing plate thickness and increased as the irradiation period was extended. Jetlite 3000 achieved control-level KHN values only when the plate thickness was 1.0 mm. At a plate thickness ≥2.0 mm, the LED units (except for PenCure 2000 at 3.0 mm) were able to achieve control-level KHN values when the irradiation time was extended. At a plate thickness of 3.0 mm, irradiation for 20 seconds with the Valo or for 80 seconds with the Demi were the only methods that produced KHN values equivalent to those produced by direct irradiation. Regardless of the type of curing unit used, indirect irradiation of dual-cured resin cement through a ceramic plate resulted in decreased KHN values compared with direct irradiation. When the irradiation period was extended, only the LED units were able to achieve similar KHN values to those observed under direct irradiation in the presence of plates ≥2.0-mm thick. High-intensity LED units require a shorter irradiation period than halogen and second-generation LED curing units to obtain KHN values similar to those observed during direct irradiation.
Task and fatigue effects on low-threshold motor units in human hand muscle.
Enoka, R M; Robinson, G A; Kossev, A R
1989-12-01
1. The activity of single motor units was recorded in the first dorsal interosseus muscle of human subjects while they performed an isometric ramp-and-hold maneuver. Motor-unit activity was characterized before and after fatigue by the use of a branched bipolar electrode that was positioned subcutaneously over the test muscle. Activity was characterized in terms of the forces of recruitment and derecruitment and the discharge pattern. The purpose was to determine, before and after fatigue, whether motor-unit activity was affected by the direction in which the force was exerted. 2. Regardless of the task during prefatigue trials, interimpulse intervals were 1) more variable during increases or decreases in force than when force was held constant at the target value (4-6% above the recruitment force), and 2) more clustered around an arbitrary central value than would be expected with a normal (Gaussian) distribution. Both effects were seen during the flexion and abduction tasks. The behavior of low-threshold motor units in first dorsal interosseus is thus largely unaffected by the direction of the force exerted by the index finger. The absence of a task (i.e., a direction of force) effect suggests that the resultant force vector about the metacarpophalangeal joint of the index finger is not coded in terms of discrete populations of motor units, but, rather, it is based on the net muscle activity about the joint. 3. Motor-unit behavior during and after fatigue showed that the relatively homogeneous behavior seen before fatigue could be severely disrupted. The fatiguing protocol involved the continuous repetition, to the endurance limit, of a 15-s ramp-and-hold maneuver in which the abduction target force was 50% of maximum and was held for 10-s epochs (ramps up and down were approximately 2 s each). Motor-unit threshold was assessed by the forces of recruitment and derecruitment associated with each cycle of the fatigue test. Changes in recruitment force during the protocol were either minimal or, when present, not systematic. In contrast, the derecruitment force of all units exhibited a marked and progressive increase over the course of the test. 4. After the fatigue test, when the initial threshold tasks were repeated, the behavior of most motor units changed. These changes included the derecruitment of previously active motor units, the recruitment of additional motor units, and an increased discharge variability of units that remained recruited. The variation in recruitment order seemed to be much greater than that reported previously for nonfatiguing conditions.(ABSTRACT TRUNCATED AT 400 WORDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Panaccione, Charles; Staab, Greg; Meuleman, Erik
ION has developed a mathematically driven model for a contacting device incorporating mass transfer, heat transfer, and computational fluid dynamics. This model is based upon a parametric structure for purposes of future commercialization. The most promising design from modeling was 3D printed and tested in a bench scale CO 2 capture unit and compared to commercially available structured packing tested in the same unit.
NASA Technical Reports Server (NTRS)
Carpenter, K. H.
1974-01-01
The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.
ERIC Educational Resources Information Center
Peterson, Norman G., Ed.
As part of the United States Army's Project A, research has been conducted to develop and field test a battery of experimental tests to complement the Armed Services Vocational Aptitude Battery in predicting soldiers' job performance. Project A is the United States Army's large-scale manpower effort to improve selection, classification, and…
NASA Technical Reports Server (NTRS)
Steele, John; Chullen, Cinda; Morenz, Jesse; Stephenson, Curtis
2010-01-01
Freon-113(TradeMark) has been used as a chemistry lab sampling solvent at NASA/JSC for EMU (extravehicular Mobility Unit) SOP (Secondary Oxygen Pack) oxygen testing Cold Traps utilized at the USA (United Space Alliance) Houston facility. Similar testing has occurred at the HSWL (Hamilton Sundstrand Windsor Locks) facility. A NASA Executive Order bans the procurement of all ODS (ozone depleting substances), including Freon-113 by the end of 2009. In order to comply with NASA direction, HSWL began evaluating viable solvents to replace Freon-113 . The study and testing effort to find Freon-113 replacements used for Cold Trap sampling is the subject of this paper. Test results have shown HFE-7100 (a 3M fluorinated ether) to be an adequate replacement for Freon-113 as a solvent to remove and measure the non-volatile residue collected in a Cold Trap during oxygen testing. Furthermore, S-316 (a Horiba Instruments Inc. high molecular weight, non-ODS chlorofluorocarbon) was found to be an adequate replacement for Freon-113 as a solvent to reconstitute non-volatile residue removed from a Cold Trap during oxygen testing for subsequent HC (hydrocarbon) analysis via FTIR (Fourier Transform Infrared Spectroscopy).
Characterization of Triaxial Braided Composite Material Properties for Impact Simulation
NASA Technical Reports Server (NTRS)
Roberts, Gary D.; Goldberg, Robert K.; Biniendak, Wieslaw K.; Arnold, William A.; Littell, Justin D.; Kohlman, Lee W.
2009-01-01
The reliability of impact simulations for aircraft components made with triaxial braided carbon fiber composites is currently limited by inadequate material property data and lack of validated material models for analysis. Improvements to standard quasi-static test methods are needed to account for the large unit cell size and localized damage within the unit cell. The deformation and damage of a triaxial braided composite material was examined using standard quasi-static in-plane tension, compression, and shear tests. Some modifications to standard test specimen geometries are suggested, and methods for measuring the local strain at the onset of failure within the braid unit cell are presented. Deformation and damage at higher strain rates is examined using ballistic impact tests on 61- by 61- by 3.2-mm (24- by 24- by 0.125-in.) composite panels. Digital image correlation techniques were used to examine full-field deformation and damage during both quasi-static and impact tests. An impact analysis method is presented that utilizes both local and global deformation and failure information from the quasi-static tests as input for impact simulations. Improvements that are needed in test and analysis methods for better predictive capability are examined.
Terence L. Wagner; Joe Mulrooney; Chris Petereson
2002-01-01
The United States Department of Agriculture Forest Service's termiticide testing program provides unbiased efficacy data for product registration using standardized tests, sites and evaluation procedures. Virtually all termiticides undergo Forest Service tests prior to registration.
Integrated arc suppression unit for defect reduction in PVD applications
NASA Astrophysics Data System (ADS)
Li, Jason; Narasimhan, Murali K.; Pavate, Vikram; Loo, David; Rosenblum, Steve; Trubell, Larry; Scholl, Richard; Seamons, Scott; Hagerty, Chris; Ramaswami, Sesh
1997-09-01
Arcing between the target and plasma during PVD deposition causes substantial damage to the target and splats and other contamination on the deposited films. Arc-related damages and defects are frequently encountered in microelectronics manufacturing and contributes largely to reduced wafer yields. Arcing is caused largely by the charge buildup at the contaminated sites on the target surface that contains either nonconducting inclusions or nodules. Arc suppression is a key issue for defect reduction, yield improvement and for reliable high quality metallization. An Integrated Arc Suppression Unit (IASU) has been designed for Endura HP PVDTM sputtering sources. The integrated design reduces cable length from unit to source and reduces electrical energy stored in the cable. Active arc handling mode, proactive arc prevention mode, and passive by-pass arc counting mode are incorporated into the same unit. The active mode is designed to quickly respond to chamber conditions, like a large chamber voltage drop, that signals a arc. The self run mode is designed to proactively prevent arc formation by pulsing and reversing target voltage at 50 kHz. The design of the IASU, also called mini small package arc repression circuit--low energy unit (mini Sparc-le), has been optimized for various DC magnetron sources, plasma stability, chamber impedance, power matching, CE MARK test, and power dissipation. Process characterization with Ti, TiN and Al sputtering indicates that the unit has little adverse impact on film properties. Mini Sparc-le unit has been shown here to significantly reduce splats occurrence in Al sputtering. Marathon test of the unit with Ti/TiN test demonstrated the unit's reliability and its ability to reduce sensitivity of defects to target characteristics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Programs
2010-06-17
The Area 5 Hazardous Waste Storage Unit (HWSU) was established to support testing, research, and remediation activities at the Nevada Test Site (NTS), a large-quantity generator of hazardous waste. The HWSU, located adjacent to the Area 5 Radioactive Waste Management Site (RWMS), is a prefabricated, rigid steel-framed, roofed shelter used to store hazardous nonradioactive waste generated on the NTS. No offsite generated wastes are managed at the HWSU. Waste managed at the HWSU includes the following categories: Flammables/Combustibles; Acid Corrosives; Alkali Corrosives; Oxidizers/Reactives; Toxics/Poisons; and Other Regulated Materials (ORMs). A list of the regulated waste codes accepted for storage atmore » the HWSU is provided in Section B.2. Hazardous wastes stored at the HWSU are stored in U.S. Department of Transportation (DOT) compliant containers, compatible with the stored waste. Waste transfer (between containers) is not allowed at the HWSU and containers remain closed at all times. Containers are stored on secondary containment pallets and the unit is inspected monthly. Table 1 provides the metric conversion factors used in this application. Table 2 provides a list of existing permits. Table 3 lists operational Resource Conservation and Recovery Act (RCRA) units at the NTS and their respective regulatory status.« less
Low-Maintenance Wind Power System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rasson, Joseph E
2010-09-30
Turbines of 1, 3 and 30 kW were designed, prototyped and evaluated. A 55 kW unit has been preliminarily designed. Two 1 kW alpha units and a 3 kW alpha unit were delivered to the US in 2005 and Empire Magnetics provided custom alternators for the units. After evaluation, the 6 bladed, 3 kW unit was chosen for beta fabrication and 5 units were delivered to the US in December, 2009 while others remained for testing in Russia.
First flight test results of the Simplified Aid For EVA Rescue (SAFER) propulsion unit
NASA Technical Reports Server (NTRS)
Meade, Carl J.
1995-01-01
The Simplified Aid for EVA Rescue (SAFER) is a small, self-contained, propulsive-backpack system that provides free-flying mobility for an astronaut engaged in a space walk, also known as extravehicular activity (EVA.) SAFER contains no redundant systems and is intended for contingency use only. In essence, it is a small, simplified version of the Manned Maneuvering Unit (MMU) last flown aboard the Space Shuttle in 1985. The operational SAFER unit will only be used to return an adrift EVA astronaut to the spacecraft. Currently, if an EVA crew member inadvertently becomes separated from the Space Shuttle, the Orbiter will maneuver to within the crew member's reach envelope, allowing the astronaut to regain contact with the Orbiter. However, with the advent of operations aboard the Russian MIR Space Station and the International Space Station, the Space Shuttle will not be available to effect a timely rescue. Under these conditions, a SAFER unit would be worn by each EVA crew member. Flight test of the pre-production model of SAFER occurred in September 1994. The crew of Space Shuttle Mission STS-64 flew a 6.9 hour test flight which included performance, flying qualities, systems, and operational utility evaluations. We found that the unit offers adequate propellant and control authority to stabilize and enable the return of a tumbling/separating crew member. With certain modifications, production model of SAFER can provide self-rescue capability to a separated crew member. This paper will present the program background, explain the flight test results and provide some insight into the complex operations of flight test in space.
Surveillance for Dengue and Dengue-Associated Neurologic Syndromes in the United States
Waterman, Stephen H.; Margolis, Harold S.; Sejvar, James J.
2015-01-01
Autochthonous dengue virus transmission has occurred in the continental United States with increased frequency during the last decade; the principal vector, Aedes aegypti, has expanded its geographic distribution in the southern United States. Dengue, a potentially fatal arboviral disease, is underreported, and US clinicians encountering patients with acute febrile illness consistent with dengue are likely to not be fully familiar with dengue diagnosis and management. Recently, investigators suggested that an outbreak of dengue likely occurred in Houston during 2003 based on retrospective laboratory testing of hospitalized cases with encephalitis and aseptic meningitis. Although certain aspects of the Houston testing results and argument for local transmission are doubtful, the report highlights the importance of prospective surveillance for dengue in Aedes-infested areas of the United States, the need for clinical training on dengue and its severe manifestations, and the need for laboratory testing in domestic patients presenting with febrile neurologic illness in these regions to include dengue. PMID:25371183
Design and development of FZU-32/B bomb fuze initiator. Final report 23 Jun 72--15 Nov 73
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miazza, J.
1974-05-01
The primary objective of this program was to develop a cost effective, production engineered FZU-24/B Bomb Fuze Initiator. The initiator is an electric generating device which, when installed in the fuze charging well of general purpose bombs, is capable of deriving energy from the airstream passing the bomb in free fall and converting the energy into electric energy suitable for powering a bomb fuze. The objective was to be accomplished by means of a production engineering effort carried through the evolution of design, fabrication, assembly, test, and evaluation. The baseline for the design was Harry Diamond Laboratories' Drawing No. 11716160.more » A quantity of 60 units was fabricated and tested, in accordance with the production engineered design. After some additional redesign to correct identified deficiencies, 220 units were fabricated. These units were subjected to environmental, wind tunnel, and flight testing and performance requirements were met. The final unit design was designated the FZU-32/B Bomb Fuze Initiator.« less
Surveillance for dengue and dengue-associated neurologic syndromes in the United States.
Waterman, Stephen H; Margolis, Harold S; Sejvar, James J
2015-05-01
Autochthonous dengue virus transmission has occurred in the continental United States with increased frequency during the last decade; the principal vector, Aedes aegypti, has expanded its geographic distribution in the southern United States. Dengue, a potentially fatal arboviral disease, is underreported, and US clinicians encountering patients with acute febrile illness consistent with dengue are likely to not be fully familiar with dengue diagnosis and management. Recently, investigators suggested that an outbreak of dengue likely occurred in Houston during 2003 based on retrospective laboratory testing of hospitalized cases with encephalitis and aseptic meningitis. Although certain aspects of the Houston testing results and argument for local transmission are doubtful, the report highlights the importance of prospective surveillance for dengue in Aedes-infested areas of the United States, the need for clinical training on dengue and its severe manifestations, and the need for laboratory testing in domestic patients presenting with febrile neurologic illness in these regions to include dengue. © The American Society of Tropical Medicine and Hygiene.
NASA Astrophysics Data System (ADS)
Nilsson, Martin; Jamot, Jakob; Malm, Tommy
2017-06-01
To field test its Stirling-dish unit, Cleanergy AB of Sweden in Q1 2015 built a ten unit demo park in Dubai. The first STE (Solar Thermal Energy) generation of its Stirling genset, the C11S, had at its core an 11 kWel Stirling engine/generator combination. The genset was mated with a parabolic concentrator developed for the genset by a supplier. Local weather conditions in Dubai provide opportunities to test performance in an environment with high insolation and high ambient temperature. In addition, the conditions in Dubai are windy, salty, humid and dusty, historically challenging for solar technologies [1]. In Q1 2016 one of the C11S Stirling-dish units was replaced by the first prototype of Cleanergy's second generation Stirling genset, the Sunbox, and an in-house developed parabolic concentrator. Operational data from field testing during the spring of 2016 are presented and discussed and show the large performance improvement achieved with the Sunbox unit.
Context matters: the impact of unit leadership and empowerment on nurses' organizational commitment.
Laschinger, Heather K Spence; Finegan, Joan; Wilk, Piotr
2009-05-01
The aim of this study was to test a multilevel model linking unit-level leader-member exchange quality and structural empowerment to nurses' psychological empowerment and organizational commitment at the individual level of analysis. Few studies have examined the contextual effects of unit leadership on individual nurse outcomes. Workplace empowerment has been related to retention outcomes such as organizational commitment in several studies, but few have studied the impact of specific unit characteristics within which nurses work on these outcomes. We surveyed 3,156 nurses in 217 hospital units to test the multilevel model. A multilevel path analysis revealed significant individual and contextual effects on nurses' organizational commitment. Both unit-level leader-member exchange quality and structural empowerment had significant direct effects on individual-level psychological empowerment and organizational commitment. Psychological empowerment mediated the relationship between core self-evaluations and organizational commitment at the individual level of analysis. The contextual effects of positive supervisor relationships and their influence on empowering working conditions at the unit level and, subsequently, nurses' organizational commitment highlight the importance of leadership for creating conditions that result in a committed nursing workforce.
40 CFR 1033.510 - Auxiliary power units.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...
40 CFR 1033.510 - Auxiliary power units.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...
40 CFR 1033.510 - Auxiliary power units.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...
40 CFR 1033.510 - Auxiliary power units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...
40 CFR 1033.510 - Auxiliary power units.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Auxiliary power units. 1033.510 Section 1033.510 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM LOCOMOTIVES Test Procedures § 1033.510 Auxiliary power units. If your...
A Saturn launched X-ray astronomy experiment. Volume 1: S-027
NASA Technical Reports Server (NTRS)
1971-01-01
The S-027 X-Ray Astronomy Experiment originally proposed in early 1966, was developed to detect X-rays in the 2 keV to 10 keV range. Both a prototype unit and flight unit were constructed with the prototype unit also serving as the engineering model, the qualification test unit, and after refurbishment, as the back-up flight unit. Two Ground Support Equipment consoles were built to verify the experiment operation. A photograph of one experiment package with its Ground Support Equipment is shown. The S-027 experiment was scheduled for launch in 1968/69 and although both units were completed and tested to the extent that either would be ready for the scheduled launch, delays in the space program resulted in a launch date slip of several years. When the 1968/69 launch delay became official, provisions were made for storage of the two experiment packages at SCI Electronics in Huntsville, Alabama until a new launch date could be established.
Advanced Plant Habitat Test Harvest
2017-08-24
John "JC" Carver, a payload integration engineer with NASA Kennedy Space Center's Test and Operations Support Contract, opens the door to the growth chamber of the Advanced Plant Habitat (APH) Flight Unit No. 1 for a test harvest of half of the Arabidopsis thaliana plants growing within. The harvest is part of an ongoing verification test of the APH unit, which is located inside the International Space Station Environmental Simulator in Kennedy's Space Station Processing Facility. The APH undergoing testing at Kennedy is identical to one on the station and uses red, green and broad-spectrum white LED lights to grow plants in an environmentally controlled chamber. The seeds grown during the verification test will be grown on the station to help scientists understand how these plants adapt to spaceflight.
Transient Testing of Nuclear Fuels and Materials in the United States
NASA Astrophysics Data System (ADS)
Wachs, Daniel M.
2012-12-01
The United States has established that transient irradiation testing is needed to support advanced light water reactors fuel development. The U.S. Department of Energy (DOE) has initiated an effort to reestablish this capability. Restart of the Transient Testing Reactor (TREAT) facility located at the Idaho National Laboratory (INL) is being considered for this purpose. This effort would also include the development of specialized test vehicles to support stagnant capsule and flowing loop tests as well as the enhancement of postirradiation examination capabilities and remote device assembly capabilities at the Hot Fuel Examination Facility. It is anticipated that the capability will be available to support testing by 2018, as required to meet the DOE goals for the development of accident-tolerant LWR fuel designs.
RE-1000 free-piston Stirling engine update
NASA Technical Reports Server (NTRS)
Schreiber, J. G.
1985-01-01
A free piston Stirling engine was tested. The tests performed over the past several years on the single cylinder engine were designed to investigate the dynamics of a free piston Stirling engine. The data are intended to be used primarily for computer code validation. The tests designed to investigate the sensitivity of the engine performance to variations in working space pressure, heater and cooler temperatures, regenerator porosity, power piston mass and displacer dynamics were completed. In addition, some data were recorded with alternate working fluids. A novel resonant balance system for the engine was also tested. Some preliminary test results of the tests performed are presented along with an outline of future tests to be run with the engine coupled to a hydraulic output unit. A description of the hydraulic output unit is given.
Comparison of current meters used for stream gaging
Fulford, Janice M.; Thibodeaux, Kirk G.; Kaehrle, William R.
1994-01-01
The U.S. Geological Survey (USGS) is field and laboratory testing the performance of several current meters used throughout the world for stream gaging. Meters tested include horizontal-axis current meters from Germany, the United Kingdom, and the People's Republic of China, and vertical-axis and electromagnetic current meters from the United States. Summarized are laboratory test results for meter repeatability, linearity, and response to oblique flow angles and preliminary field testing results. All current meters tested were found to under- and over-register velocities; errors usually increased as the velocity and angle of the flow increased. Repeatability and linearity of all meters tested were good. In the field tests, horizontal-axis meters, except for the two meters from the People's Republic of China, registered higher velocity than did the vertical-axis meters.