Sample records for changing dose rate

  1. Rates of Change in Naturalistic Psychotherapy: Contrasting Dose-Effect and Good-Enough Level Models of Change

    ERIC Educational Resources Information Center

    Baldwin, Scott A.; Berkeljon, Arjan; Atkins, David C.; Olsen, Joseph A.; Nielsen, Stevan L.

    2009-01-01

    Most research on the dose-effect model of change has combined data across patients who vary in their total dose of treatment and has implicitly assumed that the rate of change during therapy is constant across doses. In contrast, the good-enough level model predicts that rate of change will be related to total dose of therapy. In this study, the…

  2. The role of dose rate in radiation cancer risk: evaluating the effect of dose rate at the molecular, cellular and tissue levels using key events in critical pathways following exposure to low LET radiation

    PubMed Central

    Brooks, Antone L.; Hoel, David G.; Preston, R. Julian

    2016-01-01

    Abstract Purpose: This review evaluates the role of dose rate on cell and molecular responses. It focuses on the influence of dose rate on key events in critical pathways in the development of cancer. This approach is similar to that used by the U.S. EPA and others to evaluate risk from chemicals. It provides a mechanistic method to account for the influence of the dose rate from low-LET radiation, especially in the low-dose region on cancer risk assessment. Molecular, cellular, and tissues changes are observed in many key events and change as a function of dose rate. The magnitude and direction of change can be used to help establish an appropriate dose rate effectiveness factor (DREF). Conclusions: Extensive data on key events suggest that exposure to low dose-rates are less effective in producing changes than high dose rates. Most of these data at the molecular and cellular level support a large (2–30) DREF. In addition, some evidence suggests that doses delivered at a low dose rate decrease damage to levels below that observed in the controls. However, there are some data human and mechanistic data that support a dose-rate effectiveness factor of 1. In summary, a review of the available molecular, cellular and tissue data indicates that not only is dose rate an important variable in understanding radiation risk but it also supports the selection of a DREF greater than one as currently recommended by ICRP (2007) and BEIR VII (NRC/NAS 2006). PMID:27266588

  3. ELDRS Characterization for a Very High Dose Mission

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Kenna, Aaron J.; Thorbourn, Dennis O.; Clark, Karla B.; Yan, Tsun-Yee

    2010-01-01

    Evaluation of bipolar linear parts which may have Enhanced Low Dose Rate Sensitivity (ELDRS) is problematic for missions that have very high dose radiation requirements. The accepted standards for evaluating parts that display ELDRS require testing at a very low dose rate which could be prohibitively long for very high dose missions. In this work, a methodology for ELDRS characterization of bipolar parts for mission doses up to 1 Mrad(Si) is evaluated. The procedure employs an initial dose rate of 0.01 rad(Si)/s to a total dose of 50 krad(Si) and then changes to 0.04 rad(Si)/s to a total dose of 1 Mrad(Si). This procedure appears to work well. No change in rate of degradation with dose has been observed when the dose rate is changed from 0.01 to 0.04 rad(Si)/s. This is taken as an indication that the degradation due to the higher dose rate is equivalent to that at the lower dose rate at the higher dose levels, at least for the parts studied to date. In several cases, significant parameter degradation or functional failure not observed at HDR was observed at fairly high total doses (50 to 250 krad(Si)) at LDR. This behavior calls into question the use of dose rate trend data and enhancement factors to predict LDR performance.

  4. Acute changes in the central nervous system of monkeys exposed to protons.

    NASA Technical Reports Server (NTRS)

    Haymaker, W.; Ibrahim, M. Z. M.; Miquel, J.; Call, N.; Noden, P.; Ashley, W.; Ballinger, E. R.; Ghidoni, J.; Lindsay, I. R.; Behar, A. J.

    1972-01-01

    Study of the changes occurring in simian brain exposed to protons of varied energy, given in wide dose and dose-rate ranges. Results show that inflammatory reaction and glycogen accumulation in astrocytes occurred practically in all animals. Cerebral cortical necrosis, granule cell pyknosis, and inflammatory reaction occurred at doses far lower than effective for high-energy gamma radiation given other series of monkeys at comparable dose rates. Metallic impregnation, carried out in virtually all the animals tested, revealed a wide variation in glial response even at equal doses and dose rates in the same proton energy series. Proton energy effect, dose effect, dose-time effect, and dose-rate effect were evident in the various morphological categories investigated, but inconsistencies were encountered.

  5. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    NASA Technical Reports Server (NTRS)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  6. Impact of the Revised 10 CFR 835 on the Neutron Dose Rates at LLNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radev, R

    2009-01-13

    In June 2007, 10 CFR 835 [1] was revised to include new radiation weighting factors for neutrons, updated dosimetric models, and dose terms consistent with the newer ICRP recommendations. A significant aspect of the revised 10 CFR 835 is the adoption of the recommendations outlined in ICRP-60 [2]. The recommended new quantities demand a review of much of the basic data used in protection against exposure to sources of ionizing radiation. The International Commission on Radiation Units and Measurements has defined a number of quantities for use in personnel and area monitoring [3,4,5] including the ambient dose equivalent H*(d) tomore » be used for area monitoring and instrument calibrations. These quantities are used in ICRP-60 and ICRP-74. This report deals only with the changes in the ambient dose equivalent and ambient dose rate equivalent for neutrons as a result of the implementation of the revised 10 CFR 835. In the report, the terms neutron dose and neutron dose rate will be used for convenience for ambient neutron dose and ambient neutron dose rate unless otherwise stated. This report provides a qualitative and quantitative estimate of how much the neutron dose rates at LLNL will change with the implementation of the revised 10 CFR 835. Neutron spectra and dose rates from selected locations at the LLNL were measured with a high resolution spectroscopic neutron dose rate system (ROSPEC) as well as with a standard neutron rem meter (a.k.a., a remball). The spectra obtained at these locations compare well with the spectra from the Radiation Calibration Laboratory's (RCL) bare californium source that is currently used to calibrate neutron dose rate instruments. The measurements obtained from the high resolution neutron spectrometer and dose meter ROSPEC and the NRD dose meter compare within the range of {+-}25%. When the new radiation weighting factors are adopted with the implementation of the revised 10 CFR 835, the measured dose rates will increase by up to 22%. The health physicists should consider this increase for any areas that have dose rates near a posting limit, such as near the 100 mrem/hr for a high radiation area, as this increase in measured dose rate may result in some changes to postings and consequent radiological controls.« less

  7. Dose Rate Effects in Linear Bipolar Transistors

    NASA Technical Reports Server (NTRS)

    Johnston, Allan; Swimm, Randall; Harris, R. D.; Thorbourn, Dennis

    2011-01-01

    Dose rate effects are examined in linear bipolar transistors at high and low dose rates. At high dose rates, approximately 50% of the damage anneals at room temperature, even though these devices exhibit enhanced damage at low dose rate. The unexpected recovery of a significant fraction of the damage after tests at high dose rate requires changes in existing test standards. Tests at low temperature with a one-second radiation pulse width show that damage continues to increase for more than 3000 seconds afterward, consistent with predictions of the CTRW model for oxides with a thickness of 700 nm.

  8. Low-energy electron effects on tensile modulus and infrared transmission properties of a polypyromellitimide film

    NASA Technical Reports Server (NTRS)

    Ferl, J. E.; Long, E. R., Jr.

    1981-01-01

    Infrared (IR) spectroscopy and tensile modulus testing were used to evaluate the importance of experimental procedure on changes in properties of pyromellitic dianhydride-p,p prime-oxydianiline film exposed to electron radiation. The radiation exposures were accelerated, approximate equivalents to the total dose expected for a 30 year mission in geosynchronous Earth orbit. The change in the tensile modulus depends more on the dose rate and the time interval between exposure and testing than on total dose. The IR data vary with both total dose and dose rate. A threshold dose rate exists below which reversible radiation effects on the IR spectra occur. Above the threshold dose rate, irreversible effects occur with the appearance of a new band. Post-irradiation and in situ IR absorption bands are significantly different. It is suggested that the electron radiation induced metastable, excites molecular states.

  9. Passive dosimetry aboard the Mir Orbital Station: internal measurements.

    PubMed

    Benton, E R; Benton, E V; Frank, A L

    2002-10-01

    Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent. c2002 Elsevier Science Ltd. All rights reserved.

  10. Changes in ambient dose equivalent rates around roads at Kawamata town after the Fukushima accident.

    PubMed

    Kinase, Sakae; Sato, Satoshi; Sakamoto, Ryuichi; Yamamoto, Hideaki; Saito, Kimiaki

    2015-11-01

    Changes in ambient dose equivalent rates noted through vehicle-borne surveys have elucidated ecological half-lives of radioactive caesium in the environment. To confirm that the ecological half-lives are appropriate for predicting ambient dose equivalent rates within living areas, it is important to ascertain ambient dose equivalent rates on/around roads. In this study, radiation monitoring on/around roads at Kawamata town, located about 37 km northwest of the Fukushima Daiichi Nuclear Power Plant, was performed using monitoring vehicles and survey meters. It was found that the ambient dose equivalent rates around roads were higher than those on roads as of October 2012. And withal the ecological half-lives on roads were essentially consistent with those around roads. With dose predictions using ecological half-lives on roads, it is necessary to make corrections to ambient dose equivalent rates through the vehicle-borne surveys against those within living areas. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viel, Francis; Duzenli, Cheryl; British Columbia Cancer Agency, Department of Medical Physics, Vancouver Centre

    2014-08-15

    Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data andmore » a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.« less

  12. Effects of Solar Particle Event Proton Radiation on Parameters Related to Ferret Emesis

    PubMed Central

    Sanzari, J. K.; Wan, X. S.; Krigsfeld, G. S.; King, G. L.; Miller, A.; Mick, R.; Gridley, D. S.; Wroe, A. J.; Rightnar, S.; Dolney, D.; Kennedy, A. R.

    2013-01-01

    The effectiveness of simulated solar particle event (SPE) proton radiation to induce retching and vomiting was evaluated in the ferret experimental animal model. The endpoints measured in the study included: (1) the fraction of animals that retched or vomited, (2) the number of retches or vomits observed, (3) the latency period before the first retch or vomit and (4) the duration between the first and last retching or vomiting events. The results demonstrated that γ ray and proton irradiation delivered at a high dose rate of 0.5 Gy/min induced dose-dependent changes in the endpoints related to retching and vomiting. The minimum radiation doses required to induce statistically significant changes in retching- and vomiting-related endpoints were 0.75 and 1.0 Gy, respectively, and the relative biological effectiveness (RBE) of proton radiation at the high dose rate did not significantly differ from 1. Similar but less consistent and smaller changes in the retching- and vomiting-related endpoints were observed for groups irradiated with γ rays and protons delivered at a low dose rate of 0.5 Gy/h. Since this low dose rate is similar to a radiation dose rate expected during a SPE, these results suggest that the risk of SPE radiation-induced vomiting is low and may reach statistical significance only when the radiation dose reaches 1 Gy or higher. PMID:23883319

  13. Integrated molecular analysis indicates undetectable change in DNA damage in mice after continuous irradiation at ~ 400-fold natural background radiation.

    PubMed

    Olipitz, Werner; Wiktor-Brown, Dominika; Shuga, Joe; Pang, Bo; McFaline, Jose; Lonkar, Pallavi; Thomas, Aline; Mutamba, James T; Greenberger, Joel S; Samson, Leona D; Dedon, Peter C; Yanch, Jacquelyn C; Engelward, Bevin P

    2012-08-01

    In the event of a nuclear accident, people are exposed to elevated levels of continuous low dose-rate radiation. Nevertheless, most of the literature describes the biological effects of acute radiation. DNA damage and mutations are well established for their carcinogenic effects. We assessed several key markers of DNA damage and DNA damage responses in mice exposed to low dose-rate radiation to reveal potential genotoxic effects associated with low dose-rate radiation. We studied low dose-rate radiation using a variable low dose-rate irradiator consisting of flood phantoms filled with 125Iodine-containing buffer. Mice were exposed to 0.0002 cGy/min (~ 400-fold background radiation) continuously over 5 weeks. We assessed base lesions, micronuclei, homologous recombination (HR; using fluorescent yellow direct repeat mice), and transcript levels for several radiation-sensitive genes. We did not observe any changes in the levels of the DNA nucleobase damage products hypoxanthine, 8-oxo-7,8-dihydroguanine, 1,N6-ethenoadenine, or 3,N4-ethenocytosine above background levels under low dose-rate conditions. The micronucleus assay revealed no evidence that low dose-rate radiation induced DNA fragmentation, and there was no evidence of double strand break-induced HR. Furthermore, low dose-rate radiation did not induce Cdkn1a, Gadd45a, Mdm2, Atm, or Dbd2. Importantly, the same total dose, when delivered acutely, induced micronuclei and transcriptional responses. These results demonstrate in an in vivo animal model that lowering the dose-rate suppresses the potentially deleterious impact of radiation and calls attention to the need for a deeper understanding of the biological impact of low dose-rate radiation.

  14. Gamma irradiation degradation/modification of 5-ethylidene 2-norbornene (ENB)-based ethylene propylene diene rubber (EPDM) depending on ENB content of EPDM and type/content of peroxides used in vulcanization

    NASA Astrophysics Data System (ADS)

    Özdemir, Tonguç

    2008-06-01

    In this study, the radiation degradation/modification of the vulcanized EPDM and the effects of dose rate, peroxide type/content in vulcanization system and ENB content of EPDM were studied to investigate the change in the extend of the modification/degradation of the mechanical properties of vulcanized EPDM via gamma irradiation. In addition, thermal, dynamic mechanical, ATR-FTIR, TGA, TGA-FTIR tests were carried out to understand the change of properties of vulcanized EPDM via irradiation. Samples were irradiated with two different dose rates of 1280 and 64.6 Gy/h. Total dose of irradiation was up to 184 kGy. The FTIR spectral analysis showed structural changes of EPDM via irradiation. It was observed that the dose rate changed the mechanical properties with different extends. The change of ENB content of EPDM and peroxide type and content in vulcanization system affect extend of the modification/degradation of the EPDM's properties.

  15. Characterizing low dose and dose rate effects in rodent and human neural stem cells exposed to proton and gamma irradiation.

    PubMed

    Tseng, Bertrand P; Lan, Mary L; Tran, Katherine K; Acharya, Munjal M; Giedzinski, Erich; Limoli, Charles L

    2013-01-01

    Past work has shown that exposure to gamma rays and protons elicit a persistent oxidative stress in rodent and human neural stem cells (hNSCs). We have now adapted these studies to more realistic exposure scenarios in space, using lower doses and dose rates of these radiation modalities, to further elucidate the role of radiation-induced oxidative stress in these cells. Rodent neural stem and precursor cells grown as neurospheres and human neural stem cells grown as monolayers were subjected to acute and multi-dosing paradigms at differing dose rates and analyzed for changes in reactive oxygen species (ROS), reactive nitrogen species (RNS), nitric oxide and superoxide for 2 days after irradiation. While acute exposures led to significant changes in both cell types, hNSCs in particular, exhibited marked and significant elevations in radiation-induced oxidative stress. Elevated oxidative stress was more significant in hNSCs as opposed to their rodent counterparts, and hNSCs were significantly more sensitive to low dose exposures in terms of survival. Combinations of protons and γ-rays delivered as lower priming or higher challenge doses elicited radioadaptive changes that were associated with improved survival, but in general, only under conditions where the levels of reactive species were suppressed compared to cells irradiated acutely. Protective radioadaptive effects on survival were eliminated in the presence of the antioxidant N-acetylcysteine, suggesting further that radiation-induced oxidative stress could activate pro-survival signaling pathways that were sensitive to redox state. Data corroborates much of our past work and shows that low dose and dose rate exposures elicit significant changes in oxidative stress that have functional consequences on survival.

  16. Blockade of hyperpolarizing currents produces a dose-dependent effect on heart rate.

    PubMed

    Ziyatdinova, N I; Giniatullin, R A; Svyatova, N V; Zefirov, T L

    2001-03-01

    Intravenous injection of ZD 7288, a new specific hyperpolarizing current blocker, dose-dependently reduces heart rate in adult rats. The autonomic nervous system modulates changes in heart rate caused by hyperpolarizing currents.

  17. Characterizing regional-scale temporal evolution of air dose rates after the Fukushima Daiichi Nuclear Power Plant accident.

    PubMed

    Wainwright, Haruko M; Seki, Akiyuki; Mikami, Satoshi; Saito, Kimiaki

    2018-09-01

    In this study, we quantify the temporal changes of air dose rates in the regional scale around the Fukushima Dai-ichi Nuclear Power Plant in Japan, and predict the spatial distribution of air dose rates in the future. We first apply the Bayesian geostatistical method developed by Wainwright et al. (2017) to integrate multiscale datasets including ground-based walk and car surveys, and airborne surveys, all of which have different scales, resolutions, spatial coverage, and accuracy. This method is based on geostatistics to represent spatial heterogeneous structures, and also on Bayesian hierarchical models to integrate multiscale, multi-type datasets in a consistent manner. We apply this method to the datasets from three years: 2014 to 2016. The temporal changes among the three integrated maps enables us to characterize the spatiotemporal dynamics of radiation air dose rates. The data-driven ecological decay model is then coupled with the integrated map to predict future dose rates. Results show that the air dose rates are decreasing consistently across the region. While slower in the forested region, the decrease is particularly significant in the town area. The decontamination has contributed to significant reduction of air dose rates. By 2026, the air dose rates will continue to decrease, and the area above 3.8 μSv/h will be almost fully contained within the non-residential forested zone. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Replicating and extending the good-enough level model of change: considering session frequency.

    PubMed

    Reese, Robert J; Toland, Michael D; Hopkins, Nathaniel B

    2011-09-01

    The good-enough level (GEL) model posits that the rate of change in psychotherapy is related to the total dose of therapy. The psychotherapy dose-response literature has typically measured dose as number of sessions attended without considering the number of days or weeks it takes to complete the sessions (session frequency). The current study sought to replicate the GEL model and explore if session frequency moderates the influence that the number of sessions has on the rate of change in psychotherapy. An archived naturalistic data set with a US university counseling center sample (n=1,207), with treatment progress measured using the Outcome Questionnaire-45 (Lambert et al., 1996), was used. Our results are consistent with the GEL model (i.e., clients who attended fewer sessions evidenced faster rates of change), but extended it by showing that the rate of change was also influenced by session frequency (i.e., clients who attended more sessions on average per week demonstrated more rapid improvement). Evidence suggests that clinicians and researchers should give consideration to session frequency, both in their work with clients and how "dose" is operationalized in psychotherapy research.

  19. Characterization and prediction of monomer-based dose rate effects in electron-beam polymerization

    NASA Astrophysics Data System (ADS)

    Schissel, Sage M.; Lapin, Stephen C.; Jessop, Julie L. P.

    2017-12-01

    Properties of some materials produced by electron-beam (EB) induced polymerization appear dependent upon the rate at which the initiating dose was delivered. However, the magnitude of these dose rate effects (DREs) can vary greatly with different monomer formulations, suggesting DREs are dependent on chemical structure. The relationship among dose, dose rate, conversion, and the glass transition temperature (Tg) of the cured material was explored for an acrylate monomer series. A strong correlation was determined between the DRE magnitude and monomer size, and this correlation may be attributed to chain transfer. Using the Tg shift caused by changes in dose, a preliminary predictive relationship was developed to estimate the magnitude of the Tg DRE, enabling scale-up of process variables for polymers prone to dose rate effects.

  20. Dose-rate effect of ultrashort electron beam radiation on DNA damage and repair in vitro.

    PubMed

    Babayan, Nelly; Hovhannisyan, Galina; Grigoryan, Bagrat; Grigoryan, Ruzanna; Sarkisyan, Natalia; Tsakanova, Gohar; Haroutiunian, Samvel; Aroutiounian, Rouben

    2017-11-01

    Laser-generated electron beams are distinguished from conventional accelerated particles by ultrashort beam pulses in the femtoseconds to picoseconds duration range, and their application may elucidate primary radiobiological effects. The aim of the present study was to determine the dose-rate effect of laser-generated ultrashort pulses of 4 MeV electron beam radiation on DNA damage and repair in human cells. The dose rate was increased via changing the pulse repetition frequency, without increasing the electron energy. The human chronic myeloid leukemia K-562 cell line was used to estimate the DNA damage and repair after irradiation, via the comet assay. A distribution analysis of the DNA damage was performed. The same mean level of initial DNA damages was observed at low (3.6 Gy/min) and high (36 Gy/min) dose-rate irradiation. In the case of low-dose-rate irradiation, the detected DNA damages were completely repairable, whereas the high-dose-rate irradiation demonstrated a lower level of reparability. The distribution analysis of initial DNA damages after high-dose-rate irradiation revealed a shift towards higher amounts of damage and a broadening in distribution. Thus, increasing the dose rate via changing the pulse frequency of ultrafast electrons leads to an increase in the complexity of DNA damages, with a consequent decrease in their reparability. Since the application of an ultrashort pulsed electron beam permits us to describe the primary radiobiological effects, it can be assumed that the observed dose-rate effect on DNA damage/repair is mainly caused by primary lesions appearing at the moment of irradiation. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  1. Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II.

    PubMed

    Tsuda, S; Yoshida, T; Tsutsumi, M; Saito, K

    2015-01-01

    The car-borne survey system KURAMA-II, developed by the Kyoto University Research Reactor Institute, has been used for air dose rate mapping after the Fukushima Dai-ichi Nuclear Power Plant accident. KURAMA-II consists of a CsI(Tl) scintillation detector, a GPS device, and a control device for data processing. The dose rates monitored by KURAMA-II are based on the G(E) function (spectrum-dose conversion operator), which can precisely calculate dose rates from measured pulse-height distribution even if the energy spectrum changes significantly. The characteristics of KURAMA-II have been investigated with particular consideration to the reliability of the calculated G(E) function, dose rate dependence, statistical fluctuation, angular dependence, and energy dependence. The results indicate that 100 units of KURAMA-II systems have acceptable quality for mass monitoring of dose rates in the environment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Ionizing radiation sensitivity of the ocular lens and its dose rate dependence.

    PubMed

    Hamada, Nobuyuki

    2017-10-01

    In 2011, the International Commission on Radiological Protection reduced the threshold for the lens effects of low linear energy transfer (LET) radiation. On one hand, the revised threshold of 0.5 Gy is much lower than previously recommended thresholds, but mechanisms behind high radiosensitivity remain incompletely understood. On the other hand, such a threshold is independent of dose rate, in contrast to previously recommended separate thresholds each for single and fractionated/protracted exposures. Such a change was made predicated on epidemiological evidence suggesting that a threshold for fractionated/protracted exposures is not higher than an acute threshold, and that a chronic threshold is uncertain. Thus, the dose rate dependence is still unclear. This paper therefore reviews the current knowledge on the radiosensitivity of the lens and the dose rate dependence of radiation cataractogenesis, and discusses its mechanisms. Mounting biological evidence indicates that the lens cells are not necessarily radiosensitive to cell killing, and the high radiosensitivity of the lens thus appears to be attributable to other mechanisms (e.g., excessive proliferation, abnormal differentiation, a slow repair of DNA double-strand breaks, telomere, senescence, crystallin changes, non-targeted effects and inflammation). Both biological and epidemiological evidence generally supports the lack of dose rate effects. However, there is also biological evidence for the tissue sparing dose rate (or fractionation) effect of low-LET radiation and an enhancing inverse dose fractionation effect of high-LET radiation at a limited range of LET. Emerging epidemiological evidence in chronically exposed individuals implies the inverse dose rate effect. Further biological and epidemiological studies are warranted to gain deeper knowledge on the radiosensitivity of the lens and dose rate dependence of radiation cataractogenesis.

  3. Benzodiazepine sensitivity in normal human subjects.

    PubMed

    Hommer, D W; Matsuo, V; Wolkowitz, O; Chrousos, G; Greenblatt, D J; Weingartner, H; Paul, S M

    1986-06-01

    Increasing intravenous doses of diazepam or placebo were administered to ten healthy normal volunteers, and the changes in saccadic eye velocity, self-rated sedation and anxiety, and plasma cortisol and growth hormone concentrations were measured. Diazepam administration (4.4 to 140 micrograms/kg, cumulative dose) resulted in a dose-dependent decrease in saccadic eye velocity and plasma cortisol level as well as a dose-dependent increase in self-rated sedation and plasma growth hormone level. Self-rated anxiety was unaffected in these relatively nonanxious subjects. The diazepam-induced changes in saccadic eye velocity, sedation, and growth hormone and cortisol levels were highly correlated with each other and with increasing plasma diazepam concentration. These results are consistent with a benzodiazepine receptor-mediated action of diazepam. The highly quantifiable and dose-dependent decrease in saccadic eye velocity by benzodiazepines should make this a useful measure of benzodiazepine receptor sensitivity in humans.

  4. Shuttle radiation dose measurements in the International Space Station orbits

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.

    2002-01-01

    The International Space Station (ISS) is now a reality with the start of a permanent human presence on board. Radiation presents a serious risk to the health and safety of the astronauts, and there is a clear requirement for estimating their exposures prior to and after flights. Predictions of the dose rate at times other than solar minimum or solar maximum have not been possible, because there has been no method to calculate the trapped-particle spectrum at intermediate times. Over the last few years, a tissue-equivalent proportional counter (TEPC) has been flown at a fixed mid-deck location on board the Space Shuttle in 51.65 degrees inclination flights. These flights have provided data that cover the expected changes in the dose rates due to changes in altitude and changes in solar activity from the solar minimum to the solar maximum of the current 23rd solar cycle. Based on these data, a simple function of the solar deceleration potential has been derived that can be used to predict the galactic cosmic radiation (GCR) dose rates to within +/-10%. For altitudes to be covered by the ISS, the dose rate due to the trapped particles is found to be a power-law function, rho(-2/3), of the atmospheric density, rho. This relationship can be used to predict trapped dose rates inside these spacecraft to +/-10% throughout the solar cycle. Thus, given the shielding distribution for a location inside the Space Shuttle or inside an ISS module, this approach can be used to predict the combined GCR + trapped dose rate to better than +/-15% for quiet solar conditions.

  5. VMAT testing for an Elekta accelerator

    PubMed Central

    Sweeney, Larry E.; Marshall, Edward I.; Mahendra, Saikanth

    2012-01-01

    Volumetric‐modulated arc therapy (VMAT) has been shown to be able to deliver plans equivalent to intensity‐modulated radiation therapy (IMRT) in a fraction of the treatment time. This improvement is important for patient immobilization/ localization compliance due to comfort and treatment duration, as well as patient throughput. Previous authors have suggested commissioning methods for this modality. Here, we extend the methods reported for the Varian RapidArc system (which tested individual system components) to the Elekta linear accelerator, using custom files built using the Elekta iComCAT software. We also extend the method reported for VMAT commissioning of the Elekta accelerator by verifying maximum values of parameters (gantry speed, multileaf collimator (MLC) speed, and backup jaw speed), investigating: 1) beam profiles as a function of dose rate during an arc, 2) over/under dosing due to MLC reversals, and 3) over/under dosing at changing dose rate junctions. Equations for construction of the iComCAT files are given. Results indicate that the beam profile for lower dose rates varies less than 3% from that of the maximum dose rate, with no difference during an arc. The gantry, MLC, and backup jaw maximum speed are internally consistent. The monitor unit chamber is stable over the MUs and gantry movement conditions expected. MLC movement and position during VMAT delivery are within IMRT tolerances. Dose rate, gantry speed, and MLC speed are accurately controlled. Over/under dosing at junctions of MLC reversals or dose rate changes are within clinical acceptability. PACS numbers: 87.55.de, 87.55.Qr, 87.56.bd PMID:22402389

  6. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    DOEpatents

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  7. Three-dimensional dosimetric considerations from different point A definitions in cervical cancer low-dose-rate brachytherapy

    PubMed Central

    Chen, Ting; Kim, Leonard H.; Nelson, Carl; Gabel, Molly; Narra, Venkat; Haffty, Bruce; Yue, Ning J.

    2013-01-01

    Purpose To investigate the dosimetric difference due to the different point A definitions in cervical cancer low-dose-rate (LDR) intracavitary brachytherapy. Material and methods Twenty CT-based LDR brachytherapy plans of 11 cervical patients were retrospectively reviewed. Two plans with point As following the modified Manchester system which defines point A being 2 cm superior to the cervical os along the tandem and 2 cm lateral (Aos), and the American Brachytherapy Society (ABS) guideline definition in which the point A is 2 cm superior to the vaginal fornices instead of os (Aovoid) were generated. Using the same source strength, two plans prescribed the same dose to Aos and Aovoid. Dosimetric differences between plans including point A dose rate, treatment volume encompassed by the prescription isodose line (TV), and dose rate of 2 cc of the rectum and bladder to the prescription dose were measured. Results On average Aovoid was 8.9 mm superior to Aos along the tandem direction with a standard deviation of 5.4 mm. With the same source strength and arrangement, Aos dose rate was 19% higher than Aovoid dose rate. The average TV(Aovoid) was 118.0 cc, which was 30% more than the average TV(Aos) of 93.0 cc. D2cc/D(Aprescribe) increased from 51% to 60% for rectum, and increased from 89% and 106% for bladder, if the prescription point changed from Aos to Aovoid. Conclusions Different point A definitions lead to significant dose differences. Careful consideration should be given when changing practice from one point A definition to another, to ensure dosimetric and clinical equivalency from the previous clinical experiences. PMID:24474971

  8. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    PubMed

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  9. Pharmacology of saccadic eye movements in man. 1. Effects of the benzodiazepine receptor ligands midazolam and flumazenil.

    PubMed

    Ball, D M; Glue, P; Wilson, S; Nutt, D J

    1991-01-01

    A paradigm for assessing benzodiazepine receptor sensitivity was developed using intravenous midazolam in normal volunteers. After administration of incremental doses of midazolam, alterations in saccadic eye movement parameters and psychological self ratings were assessed. Significant changes included dose-dependent slowing of peak velocity, peak acceleration, peak deceleration, reduced saccade acceleration/deceleration ratio and saccade accuracy, and increased sedation self-ratings. Changes in saccade variables and sedation ratings were significantly correlated, and also correlated with plasma midazolam concentrations. No significant changes were seen in saccade latency or anxiety self-ratings. Pharmacological specificity of these changes was demonstrated by their reversal with the benzodiazepine antagonist flumazenil. This challenge paradigm appears to be a sensitive means of assessing benzodiazepine receptor function in man.

  10. Decreasing Irradiated Rat Lung Volume Changes Dose-Limiting Toxicity From Early to Late Effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veen, Sonja J. van der; Faber, Hette; Ghobadi, Ghazaleh

    2016-01-01

    Purpose: Technological developments in radiation therapy result in smaller irradiated volumes of normal tissue. Because the risk of radiation therapy-induced toxicity generally depends on irradiated volume, changing volume could change the dose-limiting toxicity of a treatment. Recently, in our rat model, we found that early radiation-induced lung dysfunction (RILD) was closely related to irradiated volume dependent vascular remodeling besides inflammation. The exact relationship between early and late RILD is still unknown. Therefore, in this preclinical study we investigated the dose-volume relationship of late RILD, assessed its dependence on early and late pathologies and studied if decreasing irradiated volume changed themore » dose-limiting toxicity. Methods and Materials: A volume of 25%, 32%, 50%, 63%, 88%, or 100% of the rat lung was irradiated using protons. Until 26 weeks after irradiation, respiratory rates were measured. Macrovascular remodeling, pulmonary inflammation, and fibrosis were assessed at 26 weeks after irradiation. For all endpoints dose-volume response curves were made. These results were compared to our previously published early lung effects. Results: Early vascular remodeling and inflammation correlated significantly with early RILD. Late RILD correlated with inflammation and fibrosis, but not with vascular remodeling. In contrast to the early effects, late vascular remodeling, inflammation and fibrosis showed a primarily dose but not volume dependence. Comparison of respiratory rate increases early and late after irradiation for the different dose-distributions indicated that with decreasing irradiated volumes, the dose-limiting toxicity changed from early to late RILD. Conclusions: In our rat model, different pathologies underlie early and late RILD with different dose-volume dependencies. Consequently, the dose-limiting toxicity changed from early to late dysfunction when the irradiated volume was reduced. In patients, early and late RILD are also due to different pathologies. As such, new radiation techniques reducing irradiated volume might change the dose-limiting toxicity of the radiation therapy treatment.« less

  11. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels

    NASA Astrophysics Data System (ADS)

    Khan, Muzafar; Heilemann, Gerd; Kuess, Peter; Georg, Dietmar; Berg, Andreas

    2018-03-01

    Recent developments in radiation therapy aimed at more precise dose delivery along with higher dose gradients (dose painting) and more efficient dose delivery with higher dose rates e.g. flattening filter free (FFF) irradiation. Magnetic-resonance-imaging based polymer gel dosimetry offers 3D information for precise dose delivery techniques. Many of the proposed polymer gels have been reported to exhibit a dose response, measured as relaxation rate ΔR2(D), which is dose rate dependent. A lack of or a reduced dose-rate sensitivity is very important for dosimetric accuracy, especially with regard to the increasing clinical use of FFF irradiation protocols with LINACs at high dose rates. Some commonly used polymer gels are based on Methacrylic-Acid-Gel-Initiated-by-Copper (MAGIC). Here, we report on the dose sensitivity (ΔR2/ΔD) of MAGIC-type gels with different oxygen scavenger concentration for their specific dependence on the applied dose rate in order to improve the dosimetric performance, especially for high dose rates. A preclinical x-ray machine (‘Yxlon’, E  =  200 kV) was used for irradiation to cover a range of dose rates from low \\dot{D} min  =  0.6 Gy min-1 to high \\dot{D} max  =  18 Gy min-1. The dose response was evaluated using R2-imaging of the gel on a human high-field (7T) MR-scanner. The results indicate that all of the investigated dose rates had an impact on the dose response in polymer gel dosimeters, being strongest in the high dose region and less effective for low dose levels. The absolute dose rate dependence \\frac{(Δ R2/Δ D)}{Δ \\dot{D}} of the dose response in MAGIC-type gel is significantly reduced using higher concentrations of oxygen scavenger at the expense of reduced dose sensitivity. For quantitative dose evaluations the relative dose rate dependence of a polymer gel, normalized to its sensitivity is important. Based on this normalized sensitivity the dose rate sensitivity was reduced distinctly using an increased oxygen scavenger concentration with reference to standard MAGIC-type gel formulation at high dose rate levels. The proposed gel composition with high oxygen scavenger concentration exhibits a larger linear active dose response and might be used especially in FFF-radiation applications and preclinical dosimetry at high dose rates. We propose in general to use high dose rates for calibration and evaluation as the change in relative dose sensitivity is reduced at higher dose rates in all of the investigated gel types.

  12. Impact of gamma radiation on the eruption rate of rat incisors

    NASA Astrophysics Data System (ADS)

    El-Faramawy, Nabil; El-Haddad, Khaled; Ali, Mohamed; Talaat, Mona

    2015-09-01

    The present work aims to test the effect of gamma radiation on the rate of eruption of rat incisors. One hundred and five adult male albino rats were used and irradiated at different gamma doses. The effects of irradiation were investigated by numerical measurements of eruption rate, histological investigation using light microscope and spectral analysis using Fourier Transform Infra-Red (FTIR). No detectable changes were observed in the groups with smaller radiation doses. There was a significant decrease in the eruption rate starting from the 4 Gy radiation dose. The observation of histological sections revealed disturbance in cellular elements responsible for eruption as well as periodontal disturbance in the samples irradiated with 4 and 6 Gy. FTIR Spectroscopy of control group and the group irradiated by 0.5 Gy showed similar absorption bands with minor differences. However, samples irradiated by 1 Gy showed significant changes in both molecular structure and conformation related to carbonates and hydroxyl groups. From the previous results, it could be concluded that gamma irradiation negatively affects the eruption rate of the rat incisors especially with higher doses.

  13. Proteomic and Epigenetic Analysis of Rice after Seed Spaceflight and Ground-Base Ion Radiations

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Sun, Yeqing; Peng, Yuming; Zhao, Qian; Wen, Bin; Yang, Jun

    Highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to plant seeds. In previous work, we compared the proteomic profiles of rice plants growing after seed spaceflights to ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) with mass spectrometry and found that the protein expression profiles were changed and differentially expressed proteins participated in most of the biological processes of rice. To further evaluate the dosage effects of space radiation and compare between low- and high-dose ion effects, we carried out three independent ground-base ionizing radiation experiments with different cumulative doses (low-dose range: 2~1000mGy, high-dose range: 2000~20000mGy) to rice seeds and performed proteomic analysis of seedlings. We found that protein expression profiles showed obvious boundaries between low- and high-dose radiation groups. Rates of differentially expressed proteins presented a dose-dependent effect, it reached the highest value at 2000mGy dosage point in all three radiation experiments coincidently; while proteins responded to low-dose radiations preferred to change their expressions at the minimum dosage (2mGy). Proteins participating in rice biological processes also responded differently between low- and high-dose radiations: proteins involved in energy metabolism and photosynthesis tended to be regulated after low-dose radiations while stress responding, protein folding and cell redox homeostasis related proteins preferred to change their expressions after high-dose radiations. By comparing the proteomic profiles between ground-base radiations and spaceflights, it was worth noting that ground-base low-dose ion radiation effects shared similar biological effects as space environment. In addition, we discovered that protein nucleoside diphosphate kinase 1 (NDPK1) showed obvious increased regulation after spaceflights and ion radiations. NDPK1 catalyzes nucleotide metabolism and is reported to be involved in DNA repair process. Its expression sensitivity and specificity were confirmed by RT-PCR and western blot analysis, indicating its potential to be used as space radiation biomarker. Space radiations might induce epigenetic effects on rice plants, especially changes of DNA methylation. Early results suggested that there were correlations between DNA methylation polymorphic and genomic mutation rates. In addition, the 5-methylcytosine located in coding gene’s promoter and exon regions could regulate gene expressions thus influence protein expressions. So whether there is correlation between genome DNA methylation changes and protein expression profile alterations caused by space radiation is worth for further investigation. Therefore we used the same rice samples treated by carbon ion radiation with different doses (0, 10, 20,100, 200, 1000, 2000, 5000, 20000mGy) and applied methylation sensitive amplification polymorphism (MSAP) for scanning genome DNA methylation changes. Interestingly, DNA methylation polymorphism rates also presented a dose-dependent effect and showed the same changing trend as rates of differentially expressed proteins. Whether there are correlations between epigenetic and proteomic effects of space radiation is worth for further investigation.

  14. Tuning the third-order nonlinear optical properties of In:ZnO thin films by 8 MeV electron beam irradiation

    NASA Astrophysics Data System (ADS)

    Shettigar, Nayana; Pramodini, S.; Kityk, I. V.; Abd-Lefdil, M.; Eljald, E. M.; Regragui, M.; Antony, Albin; Rao, Ashok; Sanjeev, Ganesh; Ajeyakashi, K. C.; Poornesh, P.

    2017-11-01

    We report the third-order nonlinear optical properties of electron beam treated Indium doped ZnO (Zn1-xInxO (x = 0.03) thin films at different dose rate. Zn1-xInxO (x = 0.03) thin films prepared by spray pyrolysis deposition technique were irradiated using 8 MeV electron beam at dose rates ranging from 1 kGy to 4 kGy. X-ray diffraction patterns were obtained to examine the structural changes, The transformation from sphalerite to wurtzite structure of ZnO was observed which indicates occurrence of structural changes due to irradiation. Morphology of irradiated thin films examined using atomic force microscopy (AFM) technique indicates the surface roughness varying with irradiation dose rate. The switching over from Saturable Absorption (SA) to Reverse Saturable Absorption (RSA) behaviour was noted when the irradiation dose rate was increased from 1 kGy to 4 kGy. The significant changes observed in the third-order nonlinear optical susceptibility χ(3) of the Zn1-xInxO (x = 0.03) thin films is attributed mainly due to electron beam irradiation. The study indicates that nonlinear optical parameters can be controlled by electron beam irradiation by choosing appropriate dose rate which is very much essential for device applications. Hence Zn1-xInxO (x = 0.03) materialize as a promising material for use in nonlinear optical device applications.

  15. Assessing dose rate distributions in VMAT plans

    NASA Astrophysics Data System (ADS)

    Mackeprang, P.-H.; Volken, W.; Terribilini, D.; Frauchiger, D.; Zaugg, K.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2016-04-01

    Dose rate is an essential factor in radiobiology. As modern radiotherapy delivery techniques such as volumetric modulated arc therapy (VMAT) introduce dynamic modulation of the dose rate, it is important to assess the changes in dose rate. Both the rate of monitor units per minute (MU rate) and collimation are varied over the course of a fraction, leading to different dose rates in every voxel of the calculation volume at any point in time during dose delivery. Given the radiotherapy plan and machine specific limitations, a VMAT treatment plan can be split into arc sectors between Digital Imaging and Communications in Medicine control points (CPs) of constant and known MU rate. By calculating dose distributions in each of these arc sectors independently and multiplying them with the MU rate, the dose rate in every single voxel at every time point during the fraction can be calculated. Independently calculated and then summed dose distributions per arc sector were compared to the whole arc dose calculation for validation. Dose measurements and video analysis were performed to validate the calculated datasets. A clinical head and neck, cranial and liver case were analyzed using the tool developed. Measurement validation of synthetic test cases showed linac agreement to precalculated arc sector times within  ±0.4 s and doses  ±0.1 MU (one standard deviation). Two methods for the visualization of dose rate datasets were developed: the first method plots a two-dimensional (2D) histogram of the number of voxels receiving a given dose rate over the course of the arc treatment delivery. In similarity to treatment planning system display of dose, the second method displays the dose rate as color wash on top of the corresponding computed tomography image, allowing the user to scroll through the variation over time. Examining clinical cases showed dose rates spread over a continuous spectrum, with mean dose rates hardly exceeding 100 cGy min-1 for conventional fractionation. A tool to analyze dose rate distributions in VMAT plans with sub-second accuracy was successfully developed and validated. Dose rates encountered in clinical VMAT test cases show a continuous spectrum with a mean less than or near 100 cGy min-1 for conventional fractionation.

  16. Investigation of natural effective gamma dose rates case study: Ardebil Province in Iran

    PubMed Central

    2012-01-01

    Gamma rays pose enough energy to induce chemical changes that may be biologically important for the normal functioning of body cells. The external exposure of human beings to natural environmental gamma radiation normally exceeds that from all man-made sources combined. In this research natural background gamma dose rates and corresponding annual effective doses were determined for selected cities of Ardebil province. Outdoor gamma dose rates were measured using an Ion Chamber Survey Meter in 105 locations in selected districts. Average absorbed doses for Ardebil, Sar-Ein, Germy, Neer, Shourabil Recreational Lake, and Kosar were determined as 265, 219, 344, 233, 352, and 358 nSv/h, respectively. Although dose rates recorded for Germi and Kosar are comparable with some areas with high natural radiation background, however, the dose rates in other districts are well below the levels reported for such locations. Average annual effective dose due to indoor and outdoor gamma radiation for Ardebil province was estimated as 1.73 (1.35–2.39) mSv, which is on average 2 times higher than the world population weighted average. PMID:23369115

  17. Dose and dose rate effects of whole-body gamma-irradiation: I. Lymphocytes and lymphoid organs

    NASA Technical Reports Server (NTRS)

    Pecaut, M. J.; Nelson, G. A.; Gridley, D. S.

    2001-01-01

    The major goal of part I of this study was to compare varying doses and dose rates of whole-body gamma-radiation on lymphoid cells and organs. C57BL/6 mice (n = 75) were exposed to 0, 0.5, 1.5, and 3.0 Gy gamma-rays (60Co) at 1 cGy/min (low-dose rate, LDR) and 80 cGy/min (high-dose rate, HDR) and euthanized 4 days later. A significant dose-dependent loss of spleen mass was observed with both LDR and HDR irradiation; for the thymus this was true only with HDR. Decreasing leukocyte and lymphocyte numbers occurred with increasing dose in blood and spleen at both dose rates. The numbers (not percentages) of CD3+ T lymphocytes decreased in the blood in a dose-dependent manner at both HDR and LDR. Splenic T cell counts decreased with dose only in HDR groups; percentages increased with dose at both dose rates. Dose-dependent decreases occurred in CD4+ T helper and CD8+ T cytotoxic cell counts at HDR and LDR. In the blood the percentages of CD4+ cells increased with increasing dose at both dose rates, whereas in the spleen the counts decreased only in the HDR groups. The percentages of the CD8+ population remained stable in both blood and spleen. CD19+ B cell counts and percentages in both compartments declined markedly with increasing HDR and LDR radiation. NK1.1+ natural killer cell numbers and proportions remained relatively stable. Overall, these data indicate that the observed changes were highly dependent on the dose, but not dose rate, and that cells in the spleen are more affected by dose rate than those in blood. The results also suggest that the response of lymphocytes in different body compartments may be variable.

  18. LAND AND WATER USE CHARACTERISTICS AND HUMAN HEALTH INPUT PARAMETERS FOR USE IN ENVIRONMENTAL DOSIMETRY AND RISK ASSESSMENTS AT THE SAVANNAH RIVER SITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jannik, T.; Karapatakis, D.; Lee, P.

    2010-08-06

    Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk andmore » vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations at SRS are documented. Based on comparisons to the 2009 SRS environmental compliance doses, the following effects are expected in future SRS compliance dose calculations: (1) Aquatic all-pathway maximally exposed individual doses may go up about 10 percent due to changes in the aquatic bioaccumulation factors; (2) Aquatic all-pathway collective doses may go up about 5 percent due to changes in the aquatic bioaccumulation factors that offset the reduction in average individual water consumption rates; (3) Irrigation pathway doses to the maximally exposed individual may go up about 40 percent due to increases in the element-specific transfer factors; (4) Irrigation pathway collective doses may go down about 50 percent due to changes in food productivity and production within the 50-mile radius of SRS; (5) Air pathway doses to the maximally exposed individual may go down about 10 percent due to the changes in food productivity in the SRS area and to the changes in element-specific transfer factors; and (6) Air pathway collective doses may go down about 30 percent mainly due to the decrease in the inhalation rate assumed for the average individual.« less

  19. OBJECT KINETIC MONTE CARLO SIMULATIONS OF RADIATION DAMAGE IN TUNGSTEN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nandipati, Giridhar; Setyawan, Wahyu; Heinisch, Howard L.

    2015-04-16

    We used our recently developed lattice-based object kinetic Monte Carlo code; KSOME [1] to carryout simulations of radiation damage in bulk tungsten at temperatures of 300, and 2050 K for various dose rates. Displacement cascades generated from molecular dynamics (MD) simulations for PKA energies at 60, 75 and 100 keV provided residual point defect distributions. It was found that the number density of vacancies in the simulation box does not change with dose rate while the number density of vacancy clusters slightly decreases with dose rate indicating that bigger clusters are formed at larger dose rates. At 300 K, althoughmore » the average vacancy cluster size increases slightly, the vast majority of vacancies exist as mono-vacancies. At 2050 K no accumulation of defects was observed during irradiation over a wide range of dose rates for all PKA energies studied in this work.« less

  20. Nicorandil, a new vasodilator drug, in patients with essential hypertension.

    PubMed

    Leonetti, G; Fruscio, M; Gradnik, R; Chianca, R; Bolla, G B; Prandi, P; Zanchetti, A

    1989-12-01

    In 12 mild to moderate hypertensive patients we investigated the acute antihypertensive efficacy of three different doses of nicorandil, a new vasodilating agent which probably acts by increasing the potassium efflux from smooth muscle cells and causing a cellular hyperpolarization. After a 3-day placebo period the patients were given, according to a double-blind Latin-square randomized design, 10, 20 and 30 mg nicorandil as a single acute dose every other day. Blood pressure and the heart rate were measured in both supine and upright positions at various times for 24 h after the dosing; fractional urine collections were obtained at the end of the placebo period and after each active dose. All doses of nicorandil similarly and significantly (P less than 0.01) reduced supine blood pressure, with a peak after 4-6 h (10 mg: -21/-8 mmHg; 20 mg: -20/-9 mmHg; 30 mg: -29/-17 mmHg), and the effect was still present, though reduced, after 24 h; no change in the heart rate was observed. The results from the upright position were similar. There were no significant changes in urine volume and electrolyte excretion during the nicorandil administration. The three different doses of nicorandil caused similar acute blood pressure reductions without change in the heart rate, nor in the urine volume and urinary sodium.

  1. Object Kinetic Monte Carlo Simulations of Radiation Damage In Bulk Tungsten

    NASA Astrophysics Data System (ADS)

    Nandipati, Giridhar; Setyawan, Wahyu; Heinisch, Howard; Roche, Kenneth; Kurtz, Richard; Wirth, Brian

    2015-11-01

    Results are presented for the evolution of radiation damage in bulk tungsten investigated using the object KMC simulation tool, KSOME, as a function of dose, dose rate and primary knock-on atom (PKA) energies in the range of 10 to 100 keV, at temperatures of 300, 1025 and 2050 K. At 300 K, the number density of vacancies changes minimally with dose rate while the number density of vacancy clusters slightly decreases with dose rate indicating that larger clusters are formed at higher dose rates. Although the average vacancy cluster size increases slightly, the vast majority exists as mono-vacancies. At 1025 K void lattice formation was observed at all dose rates for cascades below 60 keV and at lower dose rates for higher PKA energies. After the appearance of initial features of the void lattice, vacancy cluster density increased minimally while the average vacancy cluster size increases rapidly with dose. At 2050 K, no accumulation of defects was observed over a broad range of dose rates for all PKA energies studied in this work. Further comparisons of results of irradiation simulations at various dose rates and PKA spectra, representative of the High Flux Isotope Reactor and future fusion relevant irradiation facilities will be discussed. The U.S. Department of Energy, Office of Fusion Energy Sciences (FES) and Office of Advanced Scientific Computing Research (ASCR) has supported this study through the SciDAC-3 program.

  2. A strategy for reaching therapeutic salicylate levels in patients with rheumatoid arthritis using standardized dosing regimens.

    PubMed

    Furst, D E; Blocka, K; Cassell, S; Dromgoole, S; Harris, E R; Hirschberg, J M; Josephson, N; Rupp, P A; Paulus, H E; Trimble, R B

    1987-04-01

    After one to 2 weeks of 45 mg/kg/day choline magnesium trisalicylate (CMT) in 2 divided doses, 51 of 71 patients with rheumatoid arthritis (72%) had observed steady state serum salicylate concentrations between 150 and 300 mg/l (mean salicylate: 213 +/- 10 mg/l), although 17 later required dose adjustment. CMT dosing was changed in 37 cases by using the formula: dosing rate = total clearance X concentration. The expected and observed concentrations were not different (p = 0.31); thus, this formula can help calculate salicylate dosing changes to bring the serum salicylate level to within the therapeutic range.

  3. High doses of dextromethorphan, an NMDA antagonist, produce effects similar to classic hallucinogens

    PubMed Central

    Carter, Lawrence P.; Johnson, Matthew W.; Mintzer, Miriam Z.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2013-01-01

    Rationale Although reports of dextromethorphan (DXM) abuse have increased recently, few studies have examined the effects of high doses of DXM. Objective This study in humans evaluated the effects of supratherapeutic doses of DXM and triazolam. Methods Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg/70kg), and placebo were administered to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Subjective, behavioral, and physiological effects were assessed repeatedly after drug administration for 6 hours. Results Triazolam produced dose-related increases in subject-rated sedation, observer-rated sedation, and behavioral impairment. DXM produced a profile of dose-related physiological and subjective effects differing from triazolam. DXM effects included increases in blood pressure, heart rate, and emesis, increases in observer-rated effects typical of classic hallucinogens (e.g. distance from reality, visual effects with eyes open and closed, joy, anxiety), and participant ratings of stimulation (e.g. jittery, nervous), somatic effects (e.g. tingling, headache), perceptual changes, end-of-session drug liking, and mystical-type experience. After 400 mg/70kg DXM, 11 of 12 participants indicated on a pharmacological class questionnaire that they thought they had received a classic hallucinogen (e.g. psilocybin). Drug effects resolved without significant adverse effects by the end of the session. In a 1-month follow up volunteers attributed increased spirituality and positive changes in attitudes, moods, and behavior to the session experiences. Conclusions High doses of DXM produced effects distinct from triazolam and had characteristics that were similar to the classic hallucinogen psilocybin. PMID:22526529

  4. Short Communication: Rheological properties of blood serum of rats after irradiation with different gamma radiation doses in vivo.

    PubMed

    Abdelhalim, Mohamed Anwar K; Moussa, Sherif Aa; Ms, Al-Ayed

    2016-01-01

    The blood serum rheological properties open the door to find suitable radio-protectors and convenient therapy for many cases of radiation exposure. The present study aimed to investigate the rheological properties of rat blood serum at wide range of shear rates after whole body irradiation with different gamma radiation doses in vivo. Healthy male rats were divided into five groups; one control group and 4 irradiated groups. The irradiation process was carried out using Co60 source with dose rate of 0.883cG/sec. Several rheological parameters were measured using Brookfield LVDV-III Programmable rheometer. A significant increase in viscosity and shear stress was observed with 25 and 50Gy corresponding to each shear rate compared with the control; while a significant decrease observed with 75 and 100Gy. The viscosity exhibited a Non-Newtonian behaviour with the shear rate while shear stress values were linearly related with shear rate. The decrease in blood viscosity might be attributed to changes in molecular weight, pH sensitivity and protein structure. The changes in rheological properties of irradiated rats' blood serum might be attributed to destruction changes in the haematological and dimensional properties of rats' blood products.

  5. Atomoxetine Increased Effect over Time in Adults with Attention-Deficit/Hyperactivity Disorder Treated for up to 6 Months: Pooled Analysis of Two Double-Blind, Placebo-Controlled, Randomized Trials.

    PubMed

    Wietecha, Linda A; Clemow, David B; Buchanan, Andrew S; Young, Joel L; Sarkis, Elias H; Findling, Robert L

    2016-07-01

    Changes in the magnitude of efficacy throughout 26 weeks of atomoxetine treatment, along with impact of dosing, were evaluated in adults with ADHD from two randomized, double-blind, placebo-controlled studies. Pooled placebo (n = 485) and atomoxetine (n = 518) patients, dosed 25, 40, 60, 80 (target dose), or 100 mg daily, were assessed. Change from baseline in Conners' Adult ADHD Rating Scale-Investigator Rated Scale: Screening Version (CAARS) total ADHD symptoms score and Adult ADHD Investigator Symptom Rating Scale (AISRS) total score were analyzed using mixed-model repeated measures, with least squares mean change, effect size, and response rate calculated at 1, 2, 4, 8, 12, 16, 22, and 26 weeks. Decreases on CAARS for atomoxetine- versus placebo-treated patients were consistently statistically significantly greater at every time point beginning at one week (P ≤ 0.006, 0.28 effect size). By 4 weeks, comparison was -13.19 compared with -8.84 (P < 0.0001, 0.45 effect size). By 26 weeks, mean change was -15.42 versus -9.71 (0.52 effect size); increase in effect size over time was most pronounced in the 80 mg group (0.82 effect size). AISRS demonstrated similar results. Atomoxetine response rate (CAARS 50% decrease) continued to increase throughout 26 weeks. Atomoxetine treatment in adults with ADHD was associated with small effect sizes after 4 weeks and moderate effect sizes by 6 months of treatment. The data support increased effect size and response rate over time during longer-term treatment at target dose. © 2016 Eli Lilly and Company. CNS Neuroscience & Therapeutics published by John Wiley & Sons Ltd.

  6. Correlation between the Temperature Dependence of Intrsinsic Mr Parameters and Thermal Dose Measured by a Rapid Chemical Shift Imaging Technique

    PubMed Central

    Taylor, Brian A.; Elliott, Andrew M.; Hwang, Ken-Pin; Hazle, John D.; Stafford, R. Jason

    2011-01-01

    In order to investigate simultaneous MR temperature imaging and direct validation of tissue damage during thermal therapy, temperature-dependent signal changes in proton resonance frequency (PRF) shifts, R2* values, and T1-weighted amplitudes are measured from one technique in ex vivo tissue heated with a 980-nm laser at 1.5T and 3.0T. Using a multi-gradient echo acquisition and signal modeling with the Stieglitz-McBride algorithm, the temperature sensitivity coefficient (TSC) values of these parameters are measured in each tissue at high spatiotemporal resolutions (1.6×1.6×4mm3,≤5sec) at the range of 25-61 °C. Non-linear changes in MR parameters are examined and correlated with an Arrhenius rate dose model of thermal damage. Using logistic regression, the probability of changes in these parameters is calculated as a function of thermal dose to determine if changes correspond to thermal damage. Temperature calibrations demonstrate TSC values which are consistent with previous studies. Temperature sensitivity of R2* and, in some cases, T1-weighted amplitudes are statistically different before and after thermal damage occurred. Significant changes in the slopes of R2* as a function of temperature are observed. Logistic regression analysis shows that these changes could be accurately predicted using the Arrhenius rate dose model (Ω=1.01±0.03), thereby showing that the changes in R2* could be direct markers of protein denaturation. Overall, by using a chemical shift imaging technique with simultaneous temperature estimation, R2* mapping and T1-W imaging, it is shown that changes in the sensitivity of R2* and, to a lesser degree, T1-W amplitudes are measured in ex vivo tissue when thermal damage is expected to occur according to Arrhenius rate dose models. These changes could possibly be used for direct validation of thermal damage in contrast to model-based predictions. PMID:21721063

  7. Dose and dose rate effects of whole-body proton-irradiation on lymphocyte blastogenesis and hematological variables: part II

    NASA Technical Reports Server (NTRS)

    Pecaut, Michael J.; Gridley, Daila S.; Smith, Anna L.; Nelson, Gregory A.

    2002-01-01

    The goal of part II of this study was to evaluate functional characteristics of leukocytes and circulating blood cell parameters after whole-body proton irradiation at varying doses and at low- and high-dose-rates (LDR and HDR, respectively). C57BL/6 mice (n=51) were irradiated and euthanized at 4 days post-exposure for assay. Significant radiation dose- (but not dose-rate-) dependent decreases were observed in splenocyte responses to T and B cell mitogens when compared to sham-irradiated controls (P<0.001). Spontaneous blastogenesis, also significantly dose-dependent, was increased in both blood and spleen (P<0.001). Red blood cell counts, hemoglobin concentration, and hematocrit were decreased in a dose-dependent manner (P<0.05), whereas thrombocyte numbers were only slightly affected. Comparison of proton- and gamma-irradiated groups (both receiving 3 Gy at HDR) showed a higher level of spontaneous blastogenesis in blood leukocytes and a lower splenocyte response to concanavalin A following proton irradiation (P<0.05). There were no dose rate effects. Collectively, the data demonstrate that the measurements in blood and spleen were largely dependent upon the total dose of proton radiation and that an 80-fold difference in the dose rate was not a significant factor. A difference, however, was found between protons and gamma-rays in the degree of change induced in some of the measurements.

  8. Total Dose Effects on Single Event Transients in Digital CMOS and Linear Bipolar Circuits

    NASA Technical Reports Server (NTRS)

    Buchner, S.; McMorrow, D.; Sibley, M.; Eaton, P.; Mavis, D.; Dusseau, L.; Roche, N. J-H.; Bernard, M.

    2009-01-01

    This presentation discusses the effects of ionizing radiation on single event transients (SETs) in circuits. The exposure of integrated circuits to ionizing radiation changes electrical parameters. The total ionizing dose effect is observed in both complementary metal-oxide-semiconductor (CMOS) and bipolar circuits. In bipolar circuits, transistors exhibit grain degradation, while in CMOS circuits, transistors exhibit threshold voltage shifts. Changes in electrical parameters can cause changes in single event upset(SEU)/SET rates. Depending on the effect, the rates may increase or decrease. Therefore, measures taken for SEU/SET mitigation might work at the beginning of a mission but not at the end following TID exposure. The effect of TID on SET rates should be considered if SETs cannot be tolerated.

  9. Biological impact of low dose-rate simulated solar particle event radiation in vivo.

    PubMed

    Chang, P Y; Doppalapudi, R; Bakke, J; Wang, A; Menda, S; Davis, Z

    2010-08-01

    C57Bl6-lacZ animals were exposed to a range of low dose-rate simulated solar particle event (sSPE) radiation at the NASA-sponsored Research Laboratory (NSRL) at Brookhaven National Laboratory (BNL). Peripheral blood was harvested from animals from 1 to 12 days after total body irradiation (TBI) to quantify the level of circulating reticulocytes (RET) and micronucleated reticulocytes (MN-RET) as an early indicator of radiation-induced genotoxicity. Bone marrow lymphocytes and hippocampal tissues from each animal were collected at 12 days and up to two months, to evaluate dose-dependent late effects after sSPE exposure. Early hematopoietic changes show that the % RET was reduced up to 3 days in response to radiation exposure but recovered at 12 days postirradiation. The % MN-RET in peripheral blood was temporally regulated and dependant on the total accumulated dose. Total chromosome aberrations in lymphocytes increased linearly with dose within a week after radiation and remained significantly higher than the control values at 4 weeks after exposure. The level of aberrations in the irradiated animals returned to control levels by 8 weeks postirradiation. Measurements of chromosome 2 and 8 specific aberrations indicate that, consistent with conventional giemsa-staining methods, the level of aberrations is also not significantly higher than in control animals at 8 weeks postirradiation. The hippocampus was surveyed for differential transcriptional regulation of genes known to be associated with neurogenesis. Our results showed differential expression of neurotrophin and their associated receptor genes within 1 week after sSPE exposure. Progressive changes in the profile of expressed genes known to be involved in neurogenic signaling pathways were dependent on the sSPE dose. Our results to date suggest that radiation-induced changes in the hematopoietic system, i.e., chromosome aberrations in lymphocytes, are transient and do not persist past 4 weeks after radiation. On the other hand, alteration in the profile of genes known to be involved in neurotrophic functions in the hippocampal tissue appears to persist for up to 8 weeks after radiation exposure. Such temporal changes confirm that, although cytogenetic changes after a single dose of low-dose and low-dose-rate protons appear to be transient, the impact of this exposure is sufficient to lead to persistent dynamic changes in neuronal tissues long after the initial radiation exposure.

  10. The role of single-shot metronidazole in the prevention of Clostridium difficile infection following ileostomy reversal surgery.

    PubMed

    Fernandes, Roland; Robinson, Paul; Rangarajan, Karan; Scott, Sophie; Angco, Laura

    2017-05-01

    Symptomatic infection with Clostridium difficile is strongly linked to antibiotic use and rates are higher for colorectal surgery. In February 2015, trust policy for antibiotic prophylaxis of ileostomy reversal surgery was changed from three doses of metronidazole plus cefuroxime to single-dose metronidazole, in a bid to reduce rates of Clostridium difficile infection. A retrospective cohort study was conducted at a single, large hospital trust between February 2014 and February 2016, before and after change in antimicrobial policy. Theatre data, clinical notes and pathology results were all reviewed. Outcome data, patient age, gender, length of operation and hospital stay were extracted. One hundred three patients underwent ileostomy reversal surgery between February 2014 and February 2015. All received cefuroxime together with metronidazole at induction of anaesthesia followed by two further post-operative doses as operative prophylaxis. Ninety-six patients underwent ileostomy reversal surgery between February 2015 and February 2016. All received single-dose metronidazole at induction as prophylaxis. Post-operative diarrhoea was significantly reduced in patients given single-dose metronidazole compared with patients managed with multiple dose, dual antibiotic therapy (32 vs 12.5%, P 0.001). Rates of CDI were also significantly reduced in patients given single-dose metronidazole (6.8 vs 1%, P 0.038). Single-dose, pre-operative metronidazole is effective at reducing post-operative diarrhoea and CDI in ileostomy reversal surgery compared with multiple-dose cefuroxime plus metronidazole. Metronidazole may be effective as a prophylactic antibiotic against CDI in colonic surgery.

  11. Expression of Genes Associated with DNA Damage Sensing in Human Fibroblasts Exposed to Low-dose-rate Gamma Rays

    NASA Technical Reports Server (NTRS)

    Zhang, Ye; Mehta, Satish; Hammond, Diane; Pierson, Duane; Jeevarajan, Antony; Cucinotta, Francis; Rohde, Larry; Wu, Honglu

    2007-01-01

    Understanding of the molecular response to low-dose and low-dose-rate radiation exposure is essential for the extrapolation of high-dose radiation risks to those at dose levels relevant to space and other environmental concerns. Most of the reported studies of gene expressions induced by low-dose or low-dose-rate radiation were carried out on exponentially growing cells. In the present study, we analyzed expressions of 84 genes associated with DNA damage sensing using real time PCR in human fibroblasts in mostly G1 phase of the cell cycle. The cells were exposed continuously to gamma rays at a dose rate of 0.8 cGy/hr for 1, 2, 6 or 24 hrs at 37 C throughout the exposure. The total RNA was isolated immediately after the exposure was terminated. Of the 84 genes, only a few showed significant changes of the expression level. Some of the genes (e.g. DDit3 and BTG2) were found to be up or down regulated only after a short period of exposure, while other genes (e.g. PRKDC) displayed a highest expression level at the 24 hr time point. The expression profiles for the exposed cells which had a smaller portion of G1 cells indicated more cell cycle signaling and DNA repair genes either up or down regulated. Interestingly, the panel of genes changed from radiation exposure in G1 cells is different from the panel in cells having less G1 arrest cells. The gene expression profile of the cells responding to low-dose-radiation insult apparently depends on the cell growth stage. The response pathway in G1 cells may differ from that in exponentially growing cells.

  12. Cardiovascular effects of constant rate infusions of lidocaine, lidocaine and dexmedetomidine, and dexmedetomidine in dogs anesthetized at equipotent doses of sevoflurane.

    PubMed

    Moran-Muñoz, Rafael; Valverde, Alexander; Ibancovichi, J A; Acevedo-Arcique, Carlos M; Recillas-Morales, Sergio; Sanchez-Aparicio, Pedro; Osorio-Avalos, Jorge; Chavez-Monteagudo, Julio Raul

    2017-07-01

    This study evaluated the cardiovascular effects of a constant rate infusion (CRI) of lidocaine, lidocaine and dexmedetomidine, and dexmedetomidine in dogs anesthetized with sevoflurane at equipotent doses. Treatments consisted of T1-Lidocaine [loading dose 2 mg/kg body weight (BW), IV, and CRI of 100 μg/kg BW per min] at 1.4% end-tidal of sevoflurane (FE SEV ); T2-Dexmedetomidine (loading dose 2 μg/kg BW, IV, and CRI of 2 μg/kg BW per hour) and FE SEV 1.1%; and T3-Lidocaine-Dexmedetomidine using the same doses of T1 and T2 and FE SEV 0.8%. Constant rate infusion of lidocaine did not induce any cardiovascular changes; lidocaine and dexmedetomidine resulted in cardiovascular effects similar to dexmedetomidine alone. These effects were characterized by a significant ( P < 0.001) decrease in heart rate, cardiac output, cardiac index, oxygen delivery, and pulmonary vascular resistance index, and a significant ( P < 0.001) increase in mean and diastolic arterial pressure, systemic vascular resistance index, pulmonary arterial occlusion pressure and oxygen extraction ratio, compared with baseline values. In conclusion, a CRI of lidocaine combined with dexmedetomidine produces significant cardiovascular changes similar to those observed with dexmedetomidine alone.

  13. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 2. How a mistake led BEIR I to adopt LNT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J., E-mail: edwardc@schoolph.uma

    This paper reveals that nearly 25 years after the used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. -- Highlights: • The BEAR I Genetics Panel made an error in denying dose rate for mutation. •more » The BEIR I Genetics Subcommittee attempted to correct this dose rate error. • The control group used for risk assessment by BEIR I is now known to be in error. • Correcting this error contradicts the LNT, supporting a threshold model.« less

  14. Association of Medicare's Bundled Payment Reform With Changes in Use of Vitamin D Among Patients Receiving Maintenance Hemodialysis: An Interrupted Time-Series Analysis.

    PubMed

    Spoendlin, Julia; Schneeweiss, Sebastian; Tsacogianis, Theodore; Paik, Julie M; Fischer, Michael A; Kim, Seoyoung C; Desai, Rishi J

    2018-06-08

    Medicare's 2011 prospective payment system (PPS) was introduced to curb overuse of separately billable injectable drugs. After epoietin, intravenous (IV) vitamin D analogues are the biggest drug cost drivers in hemodialysis (HD) patients, but the association between PPS introduction and vitamin D therapy has been scarcely investigated. Interrupted time-series analyses. Adult US HD patients represented in the US Renal Data System between 2008 and 2013. PPS implementation. The cumulative dose of IV vitamin D analogues (paricalcitol equivalents) per patient per calendar quarter in prevalent HD patients. The average starting dose of IV vitamin D analogues and quarterly rates of new vitamin D use (initiations/100 person-months) in incident HD patients within 90 days of beginning HD therapy. Segmented linear regression models of the immediate change and slope change over time of vitamin D use after PPS implementation. Among 359,600 prevalent HD patients, IV vitamin D analogues accounted for 99% of the total use, and this trend was unchanged over time. PPS resulted in an immediate 7% decline in the average dose of IV vitamin D analogues (average baseline dose = 186.5 μg per quarter; immediate change = -13.5 μg [P < 0.001]; slope change = 0.43 per quarter [P = 0.3]) and in the starting dose of IV vitamin D analogues in incident HD patients (average baseline starting dose = 5.22 μg; immediate change = -0.40 μg [P < 0.001]; slope change = -0.03 per quarter [P = 0.03]). The baseline rate of vitamin D therapy initiation among 99,970 incident HD patients was 44.9/100 person-months and decreased over time, even before PPS implementation (pre-PPS β = -0.46/100 person-months [P < 0.001]; slope change = -0.19/100 person-months [P = 0.2]). PPS implementation was associated with an immediate change in initiation levels (by -4.5/100 person-months; P < 0.001). Incident HD patients were restricted to those 65 years or older. PPS implementation was associated with a 7% reduction in the average dose and starting dose of IV vitamin D analogues and a 10% reduction in the rate of vitamin D therapy initiation. Copyright © 2018 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  15. Method to monitor HC-SCR catalyst NOx reduction performance for lean exhaust applications

    DOEpatents

    Viola, Michael B [Macomb Township, MI; Schmieg, Steven J [Troy, MI; Sloane, Thompson M [Oxford, MI; Hilden, David L [Shelby Township, MI; Mulawa, Patricia A [Clinton Township, MI; Lee, Jong H [Rochester Hills, MI; Cheng, Shi-Wai S [Troy, MI

    2012-05-29

    A method for initiating a regeneration mode in selective catalytic reduction device utilizing hydrocarbons as a reductant includes monitoring a temperature within the aftertreatment system, monitoring a fuel dosing rate to the selective catalytic reduction device, monitoring an initial conversion efficiency, selecting a determined equation to estimate changes in a conversion efficiency of the selective catalytic reduction device based upon the monitored temperature and the monitored fuel dosing rate, estimating changes in the conversion efficiency based upon the determined equation and the initial conversion efficiency, and initiating a regeneration mode for the selective catalytic reduction device based upon the estimated changes in conversion efficiency.

  16. SU-F-BRD-04: Robustness Analysis of Proton Breast Treatments Using An Alpha-Stable Distribution Parameterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van den Heuvel, F; Hackett, S; Fiorini, F

    Purpose: Currently, planning systems allow robustness calculations to be performed, but a generalized assessment methodology is not yet available. We introduce and evaluate a methodology to quantify the robustness of a plan on an individual patient basis. Methods: We introduce the notion of characterizing a treatment instance (i.e. one single fraction delivery) by describing the dose distribution within an organ as an alpha-stable distribution. The parameters of the distribution (shape(α), scale(γ), position(δ), and symmetry(β)), will vary continuously (in a mathematical sense) as the distributions change with the different positions. The rate of change of the parameters provides a measure ofmore » the robustness of the treatment. The methodology is tested in a planning study of 25 patients with known residual errors at each fraction. Each patient was planned using Eclipse with an IBA-proton beam model. The residual error space for every patient was sampled 30 times, yielding 31 treatment plans for each patient and dose distributions in 5 organs. The parameters’ change rate as a function of Euclidean distance from the original plan was analyzed. Results: More than 1,000 dose distributions were analyzed. For 4 of the 25 patients the change in scale rate (γ) was considerably higher than the lowest change rate, indicating a lack of robustness. The sign of the shape change rate (α) also seemed indicative but the experiment lacked the power to prove significance. Conclusion: There are indications that this robustness measure is a valuable tool to allow a more patient individualized approach to the determination of margins. In a further study we will also evaluate this robustness measure using photon treatments, and evaluate the impact of using breath hold techniques, and the a Monte Carlo based dose deposition calculation. A principle component analysis is also planned.« less

  17. Detection of anatomical changes in lung cancer patients with 2D time-integrated, 2D time-resolved and 3D time-integrated portal dosimetry: a simulation study

    NASA Astrophysics Data System (ADS)

    Wolfs, Cecile J. A.; Brás, Mariana G.; Schyns, Lotte E. J. R.; Nijsten, Sebastiaan M. J. J. G.; van Elmpt, Wouter; Scheib, Stefan G.; Baltes, Christof; Podesta, Mark; Verhaegen, Frank

    2017-08-01

    The aim of this work is to assess the performance of 2D time-integrated (2D-TI), 2D time-resolved (2D-TR) and 3D time-integrated (3D-TI) portal dosimetry in detecting dose discrepancies between the planned and (simulated) delivered dose caused by simulated changes in the anatomy of lung cancer patients. For six lung cancer patients, tumor shift, tumor regression and pleural effusion are simulated by modifying their CT images. Based on the modified CT images, time-integrated (TI) and time-resolved (TR) portal dose images (PDIs) are simulated and 3D-TI doses are calculated. The modified and original PDIs and 3D doses are compared by a gamma analysis with various gamma criteria. Furthermore, the difference in the D 95% (ΔD 95%) of the GTV is calculated and used as a gold standard. The correlation between the gamma fail rate and the ΔD 95% is investigated, as well the sensitivity and specificity of all combinations of portal dosimetry method, gamma criteria and gamma fail rate threshold. On the individual patient level, there is a correlation between the gamma fail rate and the ΔD 95%, which cannot be found at the group level. The sensitivity and specificity analysis showed that there is not one combination of portal dosimetry method, gamma criteria and gamma fail rate threshold that can detect all simulated anatomical changes. This work shows that it will be more beneficial to relate portal dosimetry and DVH analysis on the patient level, rather than trying to quantify a relationship for a group of patients. With regards to optimizing sensitivity and specificity, different combinations of portal dosimetry method, gamma criteria and gamma fail rate should be used to optimally detect certain types of anatomical changes.

  18. Detection of anatomical changes in lung cancer patients with 2D time-integrated, 2D time-resolved and 3D time-integrated portal dosimetry: a simulation study.

    PubMed

    Wolfs, Cecile J A; Brás, Mariana G; Schyns, Lotte E J R; Nijsten, Sebastiaan M J J G; van Elmpt, Wouter; Scheib, Stefan G; Baltes, Christof; Podesta, Mark; Verhaegen, Frank

    2017-07-12

    The aim of this work is to assess the performance of 2D time-integrated (2D-TI), 2D time-resolved (2D-TR) and 3D time-integrated (3D-TI) portal dosimetry in detecting dose discrepancies between the planned and (simulated) delivered dose caused by simulated changes in the anatomy of lung cancer patients. For six lung cancer patients, tumor shift, tumor regression and pleural effusion are simulated by modifying their CT images. Based on the modified CT images, time-integrated (TI) and time-resolved (TR) portal dose images (PDIs) are simulated and 3D-TI doses are calculated. The modified and original PDIs and 3D doses are compared by a gamma analysis with various gamma criteria. Furthermore, the difference in the D 95% (ΔD 95% ) of the GTV is calculated and used as a gold standard. The correlation between the gamma fail rate and the ΔD 95% is investigated, as well the sensitivity and specificity of all combinations of portal dosimetry method, gamma criteria and gamma fail rate threshold. On the individual patient level, there is a correlation between the gamma fail rate and the ΔD 95% , which cannot be found at the group level. The sensitivity and specificity analysis showed that there is not one combination of portal dosimetry method, gamma criteria and gamma fail rate threshold that can detect all simulated anatomical changes. This work shows that it will be more beneficial to relate portal dosimetry and DVH analysis on the patient level, rather than trying to quantify a relationship for a group of patients. With regards to optimizing sensitivity and specificity, different combinations of portal dosimetry method, gamma criteria and gamma fail rate should be used to optimally detect certain types of anatomical changes.

  19. Temporal Change of Environmental Contamination Conditions in Five Years after the Fukushima Accident

    NASA Astrophysics Data System (ADS)

    Saito, Kimiaki

    2017-09-01

    The temporal change of environmental contamination conditions after the Fukushima accident have been clarified based on large-scale environmental monitoring data repeatedly obtained in the 80 km zone. The decreasing tendency of air dose rates was confirmed to obviously depend on land uses. In human-related diverse environments the air dose rates have decreased much faster than the physical decay of radiocesium. The horizontal movement of radiocesium in undisturbed fields were found to be generally quite small, though it has gradually penetrated into the deeper parts of the ground.

  20. Intravenous Sedation with Low-Dose Dexmedetomidine: Its Potential for Use in Dentistry

    PubMed Central

    Ogawa, Sachie; Seino, Hiroaki; Ito, Hiroshi; Yamazaki, Shinya; Ganzberg, Steven; Kawaai, Hiroyoshi

    2008-01-01

    This study investigated the physiologic and sedative parameters associated with a low-dose infusion of dexmedetomidine (Dex). Thirteen healthy volunteers were sedated with Dex at a loading dose of 6 mcg/kg/h for 5 minutes and a continuous infusion dose of 0.2 mcg/kg/h for 25 minutes. The recovery process was observed for 60 minutes post infusion. The tidal volume decreased significantly despite nonsignificant changes in respiratory rate, minute ventilation, oxygen saturation, and end-tidal carbon dioxide. The mean arterial pressure and heart rate also decreased significantly but within clinically acceptable levels. Amnesia to pin prick was present in 69% of subjects. A Trieger dot test plot error ratio did not show a significant change at 30 minutes post infusion despite a continued significant decrease in bispectral index. We conclude that sedation with a low dose of Dex appears to be safe and potentially efficacious for young healthy patients undergoing dental procedures. PMID:18788843

  1. Unilateral Versus Bilateral Laparoscopic Ovarian Drilling Using Thermal Dose Adjusted According to Ovarian Volume in CC-Resistant PCOS, A Randomized Study.

    PubMed

    El-Sayed, Mohamed Lotfy Mohamed; Ahmed, Mostafa Abdo; Mansour, Marwa Abdel Azim; Mansour, Shymma Abdel Azim

    2017-10-01

    This study aimed to evaluate the efficacy of unilateral laparoscopic ovarian drilling versus bilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume in clomiphene citrate (CC)-resistant PCOS patients in terms of endocrine changes, menstrual cycle resumption, ovulation and pregnancy rates. This study was conducted in the Department of Obstetrics and Gynecology, Zagazig university hospitals. One hundred CC-resistant PCOS patients were divided into two groups. Group (I) (50 patients) underwent unilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume (60 J/cm 3 of ovarian tissue), and group (II) (50 patients) underwent bilateral laparoscopic ovarian drilling using the same previously mentioned thermal dose. Endocrinal changes and menstrual cycle resumption were assessed within 8 weeks postoperatively, but the ovulation and pregnancy rates were estimated after 6-month follow-up period. There was no statistically significant difference between the two groups as regards demographic data ( p  > 0.05). As regards menstruation cycle resumption (62.5 vs. 81%) ( p  = 0.047), total ovulation rate (54.2 vs. 78.7%) ( p  = 0.011) and cumulative pregnancy rate (33.3 vs. 55.3%) ( p  = 0.031), there was statistically significant difference between both groups. After drilling, there were highly statistically significant decrease in the mean serum levels of luteinizing hormone (LH) and significant decrease in the mean serum levels of testosterone in both groups. Mean serum level of follicle stimulating hormone (FSH) did not change significantly in both groups after drilling. Bilateral laparoscopic ovarian drilling with thermal dose adjusted according to ovarian volume is more effective than the right-sided unilateral technique with thermal dose adjusted according to ovarian volume in terms of menstrual cycle resumption, ovulation and cumulative pregnancy rates in CC-resistant PCOS patients.

  2. Radiation exposure in the remote period after the Chernobyl accident caused oxidative stress and genetic effects in Scots pine populations

    NASA Astrophysics Data System (ADS)

    Volkova, Polina Yu.; Geras'Kin, Stanislav A.; Kazakova, Elizaveta A.

    2017-02-01

    Even 30 years after the Chernobyl accident, biological effects of irradiation are observed in the chronically exposed Scots pine populations. Chronic radiation exposure at dose rates above 50 mGy•yr-1 caused oxidative stress and led to the increase of antioxidants concentrations in these populations. Genetic variability was examined for 6 enzymes and 14 enzymatic loci of 6 Scots pine populations. Dose rates over 10 mGy•yr-1 caused the increased frequency of mutations and changes in genetic structure of Scots pine populations. However, the same dose rates had no effect on enzymatic activities. The results indicate that even relatively low dose rates of radiation can be considered as an ecological factor which should be taken into account for ecological management and radiation protection of biota species.

  3. Modelling evolution of air dose rates in river basins in Fukushima Prefecture affected by sediment-sorbed radiocesium redistribution

    NASA Astrophysics Data System (ADS)

    Malins, A.; Sakuma, K.; Nakanishi, T.; Kurikami, H.; Machida, M.; Kitamura, A.; Yamada, S.

    2015-12-01

    The radioactive 134Cs and 137Cs isotopes deposited over Fukushima Prefecture by the Fukushima Daiichi nuclear disaster are the predominant radiological concern for the years following the accident. This is because the energetic gamma radiation they emit on decay constitutes the majority of the elevated air dose rates that now afflict the region. Therefore, we developed a tool for calculating air dose rates from arbitrary radiocesium spatial distributions across the land surface and depth profiles within the ground. As cesium is strongly absorbed by clay soils, its primary redistribution mechanism within Fukushima Prefecture is by soil erosion and water-borne sediment transport. Each year between 0.1~1% of the total radiocesium inventory in the river basins neighboring Fukushima Daiichi is eroded from the land surface and enters into water courses, predominantly during typhoon storms. Although this is a small amount in relative terms, in absolute terms it corresponds to terabecquerels of 134Cs and 137Cs redistribution each year and this can affect the air dose rate at locations of high erosion and sediment deposition. This study inputs the results of sediment redistribution simulations into the dose rate evaluation tool to calculate the locations and magnitude of air dose rate changes due to radiocesium redistribution. The dose rate calculations are supported by handheld survey instrument results taken within the Prefecture.

  4. Radiation Pneumopathy in the Rat After Intravenous Application of {sup 188}Re-Labeled Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liepe, Knut; Faulhaber, Diana; Wunderlich, Gerd

    2011-10-01

    Purpose: To determine the dose dependence and kinetics of pneumopathy after systemic administration of rhenium-188 ({sup 188}Re)-labeled microspheres in a rat model. Methods and Materials: {sup 188}Re-microspheres were injected intravenously into adult Wistar rats (n = 54, age, 8 {+-} 2 months). The rats were divided into 6 groups according to the intended absorbed dose in the lung (maximum 60 Gy). Gamma camera scans were used to estimate the individual whole lung doses. One control group (n = 5) received nonlabeled microspheres. The breathing rate was measured before and weekly after the treatment using whole body plethysmography until 24 weeks.more » An increase in the breathing rate by 20% compared with the individual pretreatment control value was defined as the quantal endpoint for dose-effect analyses. Results: A biphasic increase in the breathing rate was observed. The first impairment of lung function occurred in Weeks 3-6. For late changes, the interval to onset was clearly dose dependent and was 17 weeks (10-30 Gy) and 10 weeks (50-60 Gy), respectively. The incidence of the response was highly dependent on the estimated lung dose. The median effective dose for an early and late response was virtually identical (19.9 {+-} 0.6 Gy and 20.4 {+-} 3.1 Gy, respectively). A significant correlation was found between the occurrence of an early and a late effect in the same rat, suggesting a strong consequential component. Conclusions: The effects of radiolabeled microspheres can be studied longitudinally in a rat model, using changes in the breathing rate as the functional, clinically relevant response. The isoeffective doses from the present study using radionuclide administration and those from published investigations of homogeneous external beam radiotherapy are almost similar.« less

  5. Radioinduced changes in respiration, organoleptic properties, weight, flesh firmness, and surface color of apple fruits during controlled atmosphere (CA) storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okamoto, T.; Harata, J.; Osanai, T.

    1972-03-01

    Jonathan apples were irradiated with /sup 60/Co gamma rays, with doses of 0 (control), 5, 50 and 200 Krad (dose rate: 100 Krad/hr), stored for 6.0 months in a CA room (oxygen 3%, carbon dioxide 3%) at 0 deg C and analyzed. No significant differences between irradiated and unirradiated apples in changes of weight, flesh age under CA conditions at 0 deg C. The irradiation of apple fruits with a dose of 200 Krad lowered their qualities in respect to respiration and organoleptic properties. Apples irradiated with a dose of 5 Krad, however, showed the lowest respiration rate and keptmore » superior qualities which were evaluated by organoleptic tests. According to the above results, the irradiation with 5 Krad may be recommended as the pretreatment of CA storage of apple fruite. (auth)« less

  6. Dose-response characteristics of an amorphous silicon EPID.

    PubMed

    Winkler, Peter; Hefner, Alfred; Georg, Dietmar

    2005-10-01

    Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetric properties of an amorphous silicon EPID (Elekta IVIEWGT) with respect to three photon beam qualities: 6, 10, and 25 MV. The EPID showed an excellent temporal stability on short term as well as on long term scales. The stability throughout the day was strongly influenced by warming up, which took several hours and affected EPID response by 2.5%. Ghosting effects increased the sensitivity of the EPID. They became more pronounced with decreasing time intervals between two exposures as well as with increasing dose. Due to ghosting, changes in pixel sensitivity amounted up to 16% (locally) for the 25 MV photon beam. It was observed that the response characteristics of our EPID depended on dose as well as on dose rate. Doubling the dose rate increased the EPID sensitivity by 1.5%. This behavior was successfully attributed to a dose per frame effect, i.e., a nonlinear relationship between the EPID signal and the dose which was delivered to the panel between two successive readouts. The sensitivity was found to vary up to 10% in the range of 1 to 1000 monitor units. This variation was governed by two independent effects. For low doses, the EPID signal was reduced due to the linac's changing dose rate during startup. Furthermore, the detector reading was influenced by intrabeam variations of EPID sensitivity, namely, an increase of detector response during uniform exposure. For the beam qualities which were used, the response characteristics of the EPID did not depend on energy. Differences in relative dose-response curves resulted from energy dependent temporal output characteristics of the accelerator. If ghosting is prevented from affecting the results and all dose-response effects are properly corrected for, the EPID signal becomes independent of dose rate, dose, and exposure time.

  7. An analysis of MCNP cross-sections and tally methods for low-energy photon emitters.

    PubMed

    Demarco, John J; Wallace, Robert E; Boedeker, Kirsten

    2002-04-21

    Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10-1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four cross-section datasets as well as the tally method for collision kerma versus absorbed dose. The total photon attenuation coefficient cross-section for low atomic number elements has changed significantly as cross-section data have changed between 1967 and 1989. Differences of up to 10% are observed in the photoelectric cross-section for water at 30 keV between the standard MCNP cross-section dataset (DLC-200) and the most recent XCOM/NIST tabulation. At 30 keV, the absolute dose rate in water at 1.0 cm from the source increases by 7.8% after replacing the DLC-200 photoelectric cross-sections for water with those from the XCOM/NIST tabulation. The differences in the absolute dose rate are analysed when calculated with either the MCNP absorbed dose tally or the collision kerma tally. Significant differences between the collision kerma tally and the absorbed dose tally can occur when using the DLC-200 attenuation coefficients in conjunction with a modern tabulation of mass energy-absorption coefficients.

  8. Four-dimensional dose distributions of step-and-shoot IMRT delivered with real-time tumor tracking for patients with irregular breathing: Constant dose rate vs dose rate regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang Xiaocheng; Han-Oh, Sarah; Gui Minzhi

    2012-09-15

    Purpose: Dose-rate-regulated tracking (DRRT) is a tumor tracking strategy that programs the MLC to track the tumor under regular breathing and adapts to breathing irregularities during delivery using dose rate regulation. Constant-dose-rate tracking (CDRT) is a strategy that dynamically repositions the beam to account for intrafractional 3D target motion according to real-time information of target location obtained from an independent position monitoring system. The purpose of this study is to illustrate the differences in the effectiveness and delivery accuracy between these two tracking methods in the presence of breathing irregularities. Methods: Step-and-shoot IMRT plans optimized at a reference phase weremore » extended to remaining phases to generate 10-phased 4D-IMRT plans using segment aperture morphing (SAM) algorithm, where both tumor displacement and deformation were considered. A SAM-based 4D plan has been demonstrated to provide better plan quality than plans not considering target deformation. However, delivering such a plan requires preprogramming of the MLC aperture sequence. Deliveries of the 4D plans using DRRT and CDRT tracking approaches were simulated assuming the breathing period is either shorter or longer than the planning day, for 4 IMRT cases: two lung and two pancreatic cases with maximum GTV centroid motion greater than 1 cm were selected. In DRRT, dose rate was regulated to speed up or slow down delivery as needed such that each planned segment is delivered at the planned breathing phase. In CDRT, MLC is separately controlled to follow the tumor motion, but dose rate was kept constant. In addition to breathing period change, effect of breathing amplitude variation on target and critical tissue dose distribution is also evaluated. Results: Delivery of preprogrammed 4D plans by the CDRT method resulted in an average of 5% increase in target dose and noticeable increase in organs at risk (OAR) dose when patient breathing is either 10% faster or slower than the planning day. In contrast, DRRT method showed less than 1% reduction in target dose and no noticeable change in OAR dose under the same breathing period irregularities. When {+-}20% variation of target motion amplitude was present as breathing irregularity, the two delivery methods show compatible plan quality if the dose distribution of CDRT delivery is renormalized. Conclusions: Delivery of 4D-IMRT treatment plans, stemmed from 3D step-and-shoot IMRT and preprogrammed using SAM algorithm, is simulated for two dynamic MLC-based real-time tumor tracking strategies: with and without dose-rate regulation. Comparison of cumulative dose distribution indicates that the preprogrammed 4D plan is more accurately and efficiently conformed using the DRRT strategy, as it compensates the interplay between patient breathing irregularity and tracking delivery without compromising the segment-weight modulation.« less

  9. Effects of low-dose rate γ-irradiation combined with simulated microgravity on markers of oxidative stress, DNA methylation potential, and remodeling in the mouse heart.

    PubMed

    Seawright, John W; Samman, Yusra; Sridharan, Vijayalakshmi; Mao, Xiao Wen; Cao, Maohua; Singh, Preeti; Melnyk, Stepan; Koturbash, Igor; Nelson, Gregory A; Hauer-Jensen, Martin; Boerma, Marjan

    2017-01-01

    Space travel is associated with an exposure to low-dose rate ionizing radiation and the microgravity environment, both of which may lead to impairments in cardiac function. We used a mouse model to determine short- and long-term cardiac effects to simulated microgravity (hindlimb unloading; HU), continuous low-dose rate γ-irradiation, or a combination of HU and low-dose rate γ-irradiation. Cardiac tissue was obtained from female, C57BL/6J mice 7 days, 1 month, 4 months, and 9 months following the completion of a 21 day exposure to HU or a 21 day exposure to low-dose rate γ-irradiation (average dose rate of 0.01 cGy/h to a total of 0.04 Gy), or a 21 day simultaneous exposure to HU and low-dose rate γ-irradiation. Immunoblot analysis, rt-PCR, high-performance liquid chromatography, and histology were used to assess inflammatory cell infiltration, cardiac remodeling, oxidative stress, and the methylation potential of cardiac tissue in 3 to 6 animals per group. The combination of HU and γ-irradiation demonstrated the strongest increase in reduced to oxidized glutathione ratios 7 days and 1 month after treatment, but a difference was no longer apparent after 9 months. On the other hand, no significant changes in 4-hydroxynonenal adducts was seen in any of the groups, at the measured endpoints. While manganese superoxide dismutase protein levels decreased 9 months after low-dose γ-radiation, no changes were observed in expression of catalase or Nrf2, a transcription factor that determines the expression of several antioxidant enzymes, at the measured endpoints. Inflammatory marker, CD-2 protein content was significantly decreased in all groups 4 months after treatment. No significant differences were observed in α-smooth muscle cell actin protein content, collagen type III protein content or % total collagen. This study has provided the first and relatively broad analysis of small molecule and protein markers of oxidative stress, T-lymphocyte infiltration, and cardiac remodeling in response to HU with simultaneous exposure to low-dose rate γ-radiation. Results from the late observation time points suggest that the hearts had mostly recovered from these two experimental conditions. However, further research is needed with larger numbers of animals for a more robust statistical power to fully characterize the early and late effects of simulated microgravity combined with exposure to low-dose rate ionizing radiation on the heart.

  10. Effects of low-dose rate γ-irradiation combined with simulated microgravity on markers of oxidative stress, DNA methylation potential, and remodeling in the mouse heart

    PubMed Central

    Samman, Yusra; Sridharan, Vijayalakshmi; Mao, Xiao Wen; Cao, Maohua; Singh, Preeti; Melnyk, Stepan; Koturbash, Igor; Nelson, Gregory A.; Hauer-Jensen, Martin; Boerma, Marjan

    2017-01-01

    Purpose Space travel is associated with an exposure to low-dose rate ionizing radiation and the microgravity environment, both of which may lead to impairments in cardiac function. We used a mouse model to determine short- and long-term cardiac effects to simulated microgravity (hindlimb unloading; HU), continuous low-dose rate γ-irradiation, or a combination of HU and low-dose rate γ-irradiation. Methods Cardiac tissue was obtained from female, C57BL/6J mice 7 days, 1 month, 4 months, and 9 months following the completion of a 21 day exposure to HU or a 21 day exposure to low-dose rate γ-irradiation (average dose rate of 0.01 cGy/h to a total of 0.04 Gy), or a 21 day simultaneous exposure to HU and low-dose rate γ-irradiation. Immunoblot analysis, rt-PCR, high-performance liquid chromatography, and histology were used to assess inflammatory cell infiltration, cardiac remodeling, oxidative stress, and the methylation potential of cardiac tissue in 3 to 6 animals per group. Results The combination of HU and γ-irradiation demonstrated the strongest increase in reduced to oxidized glutathione ratios 7 days and 1 month after treatment, but a difference was no longer apparent after 9 months. On the other hand, no significant changes in 4-hydroxynonenal adducts was seen in any of the groups, at the measured endpoints. While manganese superoxide dismutase protein levels decreased 9 months after low-dose γ-radiation, no changes were observed in expression of catalase or Nrf2, a transcription factor that determines the expression of several antioxidant enzymes, at the measured endpoints. Inflammatory marker, CD-2 protein content was significantly decreased in all groups 4 months after treatment. No significant differences were observed in α-smooth muscle cell actin protein content, collagen type III protein content or % total collagen. Conclusions This study has provided the first and relatively broad analysis of small molecule and protein markers of oxidative stress, T-lymphocyte infiltration, and cardiac remodeling in response to HU with simultaneous exposure to low-dose rate γ-radiation. Results from the late observation time points suggest that the hearts had mostly recovered from these two experimental conditions. However, further research is needed with larger numbers of animals for a more robust statistical power to fully characterize the early and late effects of simulated microgravity combined with exposure to low-dose rate ionizing radiation on the heart. PMID:28678877

  11. Dosimetric impact of applicator displacement during high dose rate (HDR) Cobalt-60 brachytherapy for cervical cancer: A planning study

    NASA Astrophysics Data System (ADS)

    Yong, J. S.; Ung, N. M.; Jamalludin, Z.; Malik, R. A.; Wong, J. H. D.; Liew, Y. M.; Ng, K. H.

    2016-02-01

    We investigated the dosimetric impact of applicator displacement on dose specification during high dose rate (HDR) Cobalt-60 (Co-60) brachytherapy for cervical cancer through a planning study. Eighteen randomly selected HDR full insertion plans were restrospectively studied. The tandem and ovoids were virtually shifted translationally and rotationally in the x-, y- and z-axis directions on the treatment planning system. Doses to reference points and volumes of interest in the plans with shifted applicators were compared with the original plans. The impact of dose displacement on 2D (point-based) and 3D (volume-based) treatment planning techniques was also assessed. A ±2 mm translational y-axis applicator shift and ±4° rotational x-axis applicator shift resulted in dosimetric changes of more than 5% to organs at risk (OAR) reference points. Changes to the maximum doses to 2 cc of the organ (D2cc) in 3D planning were statistically significant and higher than the reference points in 2D planning for both the rectum and bladder (p<0.05). Rectal D2cc was observed to be the most sensitive to applicator displacement among all dose metrics. Applicator displacement that is greater than ±2 mm translational y-axis and ±4° rotational x-axis resulted in significant dose changes to the OAR. Thus, steps must be taken to minimize the possibility of applicator displacement during brachytherapy.

  12. Evaluation of rotigotine transdermal patch for the treatment of apathy and motor symptoms in Parkinson's disease.

    PubMed

    Hauser, Robert A; Slawek, Jaroslaw; Barone, Paolo; Dohin, Elisabeth; Surmann, Erwin; Asgharnejad, Mahnaz; Bauer, Lars

    2016-06-07

    This multicenter, double-blind, placebo-controlled study assessed the efficacy of rotigotine transdermal patch on apathy and motor symptoms in patients with Parkinson's disease (PD). Patients with PD-associated apathy (Unified Parkinson's Disease Rating Scale [UPDRS] I item 4 [motivation] ≥2 and patient-rated Apathy Scale [AS] ≥14) were randomized 1:1:1 to "low-dose" rotigotine (≤6 mg/24 h for early PD [those not receiving levodopa] or ≤8 mg/24 h for advanced PD [those receiving levodopa]), "high-dose" rotigotine (≤8 mg/24 h for early PD or ≤16 mg/24 h for advanced PD), or placebo, and maintained at optimal/maximal dose for 12 weeks. Coprimary efficacy variables were: change from baseline to End of Maintenance in patient-rated AS and UPDRS II + III total score. Recruitment was stopped after an interim futility analysis; therefore, all p values are exploratory. Of 122 patients randomized, 81.1 % completed the study (placebo, n = 32/40 [80.0 %]; low-dose rotigotine, n = 30/41 [73.2 %]; high-dose rotigotine, n = 37/41 [90.2 %]). No treatment difference was observed in the change in patient-rated AS (least squares mean [95 % confidence interval (CI)] difference: low-dose, 0.04 [-2.42, 2.50], p =0.977; high-dose, -0.22 [-2.61, 2.18], p = 0.859). Rotigotine improved UPDRS II + III total scores versus placebo (least squares mean [95 % CI] treatment difference: low-dose, -7.29 [-12.30, -2.28], p = 0.005; high-dose, -6.06 [-10.90, -1.21], p = 0.015), and the "mood/apathy" domain of the Non-Motor Symptom Scale as rated by the investigator (secondary outcome). The most frequent adverse events in rotigotine-treated patients were application site reactions, somnolence, and nausea. Rotigotine did not improve PD-associated apathy as rated by the patient but provided clinically relevant improvement in motor control and activities of daily living. ClinicalTrials.gov identifier NCT01782222 . Trial registration date: January 30, 2013.

  13. Psilocybin-occasioned mystical-type experience in combination with meditation and other spiritual practices produces enduring positive changes in psychological functioning and in trait measures of prosocial attitudes and behaviors.

    PubMed

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A

    2018-01-01

    Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level ("standard") support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282.

  14. Psilocybin-occasioned mystical-type experience in combination with meditation and other spiritual practices produces enduring positive changes in psychological functioning and in trait measures of prosocial attitudes and behaviors

    PubMed Central

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; Jesse, Robert; MacLean, Katherine A; Barrett, Frederick S; Cosimano, Mary P; Klinedinst, Maggie A

    2017-01-01

    Psilocybin can occasion mystical-type experiences with participant-attributed increases in well-being. However, little research has examined enduring changes in traits. This study administered psilocybin to participants who undertook a program of meditation/spiritual practices. Healthy participants were randomized to three groups (25 each): (1) very low-dose (1 mg/70 kg on sessions 1 and 2) with moderate-level (“standard”) support for spiritual-practice (LD-SS); (2) high-dose (20 and 30 mg/70 kg on sessions 1 and 2, respectively) with standard support (HD-SS); and (3) high-dose (20 and 30 mg/70kg on sessions 1 and 2, respectively) with high support for spiritual practice (HD-HS). Psilocybin was administered double-blind and instructions to participants/staff minimized expectancy confounds. Psilocybin was administered 1 and 2 months after spiritual-practice initiation. Outcomes at 6 months included rates of spiritual practice and persisting effects of psilocybin. Compared with low-dose, high-dose psilocybin produced greater acute and persisting effects. At 6 months, compared with LD-SS, both high-dose groups showed large significant positive changes on longitudinal measures of interpersonal closeness, gratitude, life meaning/purpose, forgiveness, death transcendence, daily spiritual experiences, religious faith and coping, and community observer ratings. Determinants of enduring effects were psilocybin-occasioned mystical-type experience and rates of meditation/spiritual practices. Psilocybin can occasion enduring trait-level increases in prosocial attitudes/behaviors and in healthy psychological functioning. Trial Registration ClinicalTrials.gov Identifier NCT00802282 PMID:29020861

  15. Radiation Hormesis: Historical Perspective and Implications for Low-Dose Cancer Risk Assessment

    PubMed Central

    Vaiserman, Alexander M.

    2010-01-01

    Current guidelines for limiting exposure of humans to ionizing radiation are based on the linear-no-threshold (LNT) hypothesis for radiation carcinogenesis under which cancer risk increases linearly as the radiation dose increases. With the LNT model even a very small dose could cause cancer and the model is used in establishing guidelines for limiting radiation exposure of humans. A slope change at low doses and dose rates is implemented using an empirical dose and dose rate effectiveness factor (DDREF). This imposes usually unacknowledged nonlinearity but not a threshold in the dose-response curve for cancer induction. In contrast, with the hormetic model, low doses of radiation reduce the cancer incidence while it is elevated after high doses. Based on a review of epidemiological and other data for exposure to low radiation doses and dose rates, it was found that the LNT model fails badly. Cancer risk after ordinarily encountered radiation exposure (medical X-rays, natural background radiation, etc.) is much lower than projections based on the LNT model and is often less than the risk for spontaneous cancer (a hormetic response). Understanding the mechanistic basis for hormetic responses will provide new insights about both risks and benefits from low-dose radiation exposure. PMID:20585444

  16. [Study on effect of aqueous extracts from aconite on "dose-time-toxicity" relationships in mice hearts].

    PubMed

    Feng, Qun; Li, Xiao-yu; Luan, Yong-fu; Sun, Sai-nan; Sun, Rong

    2015-03-01

    To study the effect of single administration of aqueous extracts from aconite on "dose-toxicity" relationship and "time-toxicity" relationship of mice hearts, through changes in electrocardiogram (ECG) and serum biochemical indexes. Mice were grouped according to different drug doses and time points, and orally administered with water extracts from aconite for once to observe the changes of mice ECG before and after the administration, calculate visceral indexes heart, liver and kidney, and detect levels of CK, LDH, BNP and CTn-I in serum. According to the "time-toxicity" relationship study, at 5 min after oral administration with aqueous extracts from aconite in mice, the heart rate of mice began rising, reached peak at 60 min and then slowly reduced; QRS, R amplitude, T duration and amplitude and QT interval declined at 5 min, reduced to the bottom at 60 min and then gradually elevated. The levels of CK, LDH, BNP and CTn-I in serum elevated at 5 min and reached the peak at 60 min, with no significant change in ratios of organs to body at different time points. On the basis of the "dose-toxicity" relationship, with the increase in single dose of aqueous extracts from aconite, the heart rate of mice. QRS, T duration and amplitude and QT interval declined gradually, and levels of CK, LDH, BNP and CTn-I in serum slowly elevated, with a certain dose dependence and no significant change in ratios of organs to body in mice. Single oral administration of different doses of aqueous extracts from aconite could cause different degrees of heart injury at different time points, with a certain dose dependence. Its peak time of toxicity is at 60 min after the administration of aqueous extracts from aconite.

  17. Dose-Rate Effects in Breaking DNA Strands by Short Pulses of Extreme Ultraviolet Radiation.

    PubMed

    Vyšín, Luděk; Burian, Tomáš; Ukraintsev, Egor; Davídková, Marie; Grisham, Michael E; Heinbuch, Scott; Rocca, Jorge J; Juha, Libor

    2018-05-01

    In this study, we examined dose-rate effects on strand break formation in plasmid DNA induced by pulsed extreme ultraviolet (XUV) radiation. Dose delivered to the target molecule was controlled by attenuating the incident photon flux using aluminum filters as well as by changing the DNA/buffer-salt ratio in the irradiated sample. Irradiated samples were examined using agarose gel electrophoresis. Yields of single- and double-strand breaks (SSBs and DSBs) were determined as a function of the incident photon fluence. In addition, electrophoresis also revealed DNA cross-linking. Damaged DNA was inspected by means of atomic force microscopy (AFM). Both SSB and DSB yields decreased with dose rate increase. Quantum yields of SSBs at the highest photon fluence were comparable to yields of DSBs found after synchrotron irradiation. The average SSB/DSB ratio decreased only slightly at elevated dose rates. In conclusion, complex and/or clustered damages other than cross-links do not appear to be induced under the radiation conditions applied in this study.

  18. Optimal mapping of terrestrial gamma dose rates using geological parent material and aerogeophysical survey data.

    PubMed

    Rawlins, B G; Scheib, C; Tyler, A N; Beamish, D

    2012-12-01

    Regulatory authorities need ways to estimate natural terrestrial gamma radiation dose rates (nGy h⁻¹) across the landscape accurately, to assess its potential deleterious health effects. The primary method for estimating outdoor dose rate is to use an in situ detector supported 1 m above the ground, but such measurements are costly and cannot capture the landscape-scale variation in dose rates which are associated with changes in soil and parent material mineralogy. We investigate the potential for improving estimates of terrestrial gamma dose rates across Northern Ireland (13,542 km²) using measurements from 168 sites and two sources of ancillary data: (i) a map based on a simplified classification of soil parent material, and (ii) dose estimates from a national-scale, airborne radiometric survey. We used the linear mixed modelling framework in which the two ancillary variables were included in separate models as fixed effects, plus a correlation structure which captures the spatially correlated variance component. We used a cross-validation procedure to determine the magnitude of the prediction errors for the different models. We removed a random subset of 10 terrestrial measurements and formed the model from the remainder (n = 158), and then used the model to predict values at the other 10 sites. We repeated this procedure 50 times. The measurements of terrestrial dose vary between 1 and 103 (nGy h⁻¹). The median absolute model prediction errors (nGy h⁻¹) for the three models declined in the following order: no ancillary data (10.8) > simple geological classification (8.3) > airborne radiometric dose (5.4) as a single fixed effect. Estimates of airborne radiometric gamma dose rate can significantly improve the spatial prediction of terrestrial dose rate.

  19. Use of radiation protraction to escalate biologically effective dose to the treatment target

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuperman, V. Y.; Spradlin, G. S.; Department of Mathematics, Embry-Riddle University, Daytona Beach, Florida 32114

    2011-12-15

    Purpose: The aim of this study is to evaluate how simultaneously increasing fraction time and dose per fraction affect biologically effective dose for the target (BED{sub tar}) while biologically effective dose for the normal tissue (BED{sub nt}) is fixed. Methods: In this investigation, BED{sub tar} and BED{sub nt} were studied by assuming mono-exponential repair of sublethal damage with tissue dependent repair half-time. Results: Our results demonstrate that under certain conditions simultaneously increasing fraction time and dose per fraction result in increased BED{sub tar} while BED{sub nt} is fixed. The dependence of biologically effective dose on fraction time is influenced bymore » the dose rate. In this investigation we analytically determined time-varying dose rate R-tilde which minimizes BED. Changes in BED with fraction time were compared for constant dose rate and for R-tilde. Conclusions: A number of recent experimental and theoretical studies have demonstrated that slow delivery of radiation (known as radiation protraction) leads to reduced therapeutic effect because of increased repair of sublethal damage. In contrast, our analysis shows that under certain conditions simultaneously increasing fraction time and dose per fraction are radiobiologically advantageous.« less

  20. Detection of IMRT delivery errors based on a simple constancy check of transit dose by using an EPID

    NASA Astrophysics Data System (ADS)

    Baek, Tae Seong; Chung, Eun Ji; Son, Jaeman; Yoon, Myonggeun

    2015-11-01

    Beam delivery errors during intensity modulated radiotherapy (IMRT) were detected based on a simple constancy check of the transit dose by using an electronic portal imaging device (EPID). Twenty-one IMRT plans were selected from various treatment sites, and the transit doses during treatment were measured by using an EPID. Transit doses were measured 11 times for each course of treatment, and the constancy check was based on gamma index (3%/3 mm) comparisons between a reference dose map (the first measured transit dose) and test dose maps (the following ten measured dose maps). In a simulation using an anthropomorphic phantom, the average passing rate of the tested transit dose was 100% for three representative treatment sites (head & neck, chest, and pelvis), indicating that IMRT was highly constant for normal beam delivery. The average passing rate of the transit dose for 1224 IMRT fields from 21 actual patients was 97.6% ± 2.5%, with the lower rate possibly being due to inaccuracies of patient positioning or anatomic changes. An EPIDbased simple constancy check may provide information about IMRT beam delivery errors during treatment.

  1. A diamond detector in the dosimetry of high-energy electron and photon beams.

    PubMed

    Laub, W U; Kaulich, T W; Nüsslin, F

    1999-09-01

    A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rate was found. Detector current and dose rate are related by the expression i alpha Ddelta, where i is the detector current, D is the dose rate and delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.

  2. Digital holographic interferometry: a novel optical calorimetry technique for radiation dosimetry.

    PubMed

    Cavan, Alicia; Meyer, Juergen

    2014-02-01

    To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ± 3.45 Gy (corresponding to an uncertainty in the temperature value of ± 8.3 × 10(-4) K). The relative dose fall off was in agreement with treatment planning system modeled data. First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10(-4) m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  3. A Detailed Dosimetric Analysis of Spinal Cord Tolerance in High-Dose Spine Radiosurgery.

    PubMed

    Katsoulakis, Evangelia; Jackson, Andrew; Cox, Brett; Lovelock, Michael; Yamada, Yoshiya

    2017-11-01

    Dose-volume tolerance of the spinal cord (SC) in spinal stereotactic radiosurgery (SRS) is difficult to define because radiation myelitis rates are low, and published reports document cases of myelopathy but do not account for the total number of patients treated at given dose-volume combinations who do not have myelitis. This study reports SC toxicity from single-fraction spinal SRS and presents a comprehensive atlas of the incidence of adverse events to examine dose-volume predictors. A prospective database of all patients undergoing single-fraction spinal SRS at our institution between 2004 and 2011 was reviewed. SC toxicity was defined by clinical myelitis with accompanying magnetic resonance imaging (MRI) signal changes that were not attributable to tumor progression. Dose-volume histogram (DVH) atlases were created for these endpoints. Rates of adverse events with 95% confidence limits and probabilities that rates of adverse events were <2% and <5% for myelitis were determined as functions of dose and absolute volume. Information about DVH and myelitis was available for 228 patients treated at 259 sites. The median follow-up time was 14.6 months (range, 0.1-138.3 months). The median prescribed dose to the planning treatment volume was 24 Gy (range, 18-24 Gy). There were 2 cases of radiation myelitis (rate r=0.7%) with accompanying MRI signal changes. Myelitis occurred in 2 patients, with Dmax >13.33 Gy, and minimum doses to the hottest 0.1, 0.2, 0.5, and 1 cc were >10.66, 10.9, and 8 Gy, respectively; however, both myelitis cases occurred below the 34th percentile for Dmax and there were 194 DVHs in total with Dmax >13.33 Gy. A median SC Dmax of 13.85 Gy is safe and supports that a Dmax limit of 14 Gy carries a low <1% rate of myelopathy. No dose-volume thresholds or relationships between SC dose and myelitis were apparent. This is the largest study examining dosimetric data and radiation-induced myelitis in de novo spine SRS. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. MODELING THE VARIATIONS OF DOSE RATE MEASURED BY RAD DURING THE FIRST MSL MARTIAN YEAR: 2012–2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Jingnan; Wimmer-Schweingruber, Robert F.; Heber, Bernd

    2015-09-01

    The Radiation Assessment Detector (RAD), on board Mars Science Laboratory’s (MSL) rover Curiosity, measures the energy spectra of both energetic charged and neutral particles along with the radiation dose rate at the surface of Mars. With these first-ever measurements on the Martian surface, RAD observed several effects influencing the galactic cosmic-ray (GCR) induced surface radiation dose concurrently: (a) short-term diurnal variations of the Martian atmospheric pressure caused by daily thermal tides, (b) long-term seasonal pressure changes in the Martian atmosphere, and (c) the modulation of the primary GCR flux by the heliospheric magnetic field, which correlates with long-term solar activitymore » and the rotation of the Sun. The RAD surface dose measurements, along with the surface pressure data and the solar modulation factor, are analyzed and fitted to empirical models that quantitatively demonstrate how the long-term influences ((b) and (c)) are related to the measured dose rates. Correspondingly, we can estimate dose rate and dose equivalents under different solar modulations and different atmospheric conditions, thus allowing empirical predictions of the Martian surface radiation environment.« less

  5. A randomized, double-blind, placebo-controlled, dose-ranging study of lisdexamfetamine dimesylate augmentation for major depressive disorder in adults with inadequate response to antidepressant therapy

    PubMed Central

    Richards, Cynthia; Iosifescu, Dan V; Mago, Rajnish; Sarkis, Elias; Reynolds, James; Geibel, Brooke; Dauphin, Matthew

    2017-01-01

    Background: This randomized, double-blind, placebo-controlled study evaluated dose-response relationships of lisdexamfetamine dimesylate when used as augmentation for major depressive disorder in individuals exhibiting inadequate responses to antidepressant monotherapy. Methods: Eligible adults (18–65 years) were assigned to antidepressant monotherapy (escitalopram or venlafaxine extended-release) plus lisdexamfetamine dimesylate-matching placebo during an eight-week single-blind lead-in phase. Participants meeting randomization criteria were randomized (1:1:1:1:1) to eight weeks of lisdexamfetamine dimesylate (10, 30, 50, or 70 mg) or placebo while maintaining antidepressant therapy. Dose-responses for changes from augmentation baseline to week 16/early termination for Montgomery-Åsberg Depression Rating Scale total score (primary efficacy endpoint) and vital signs (systolic and diastolic blood pressure and pulse) were assessed using multiple comparisons procedures with modeling. Results: For Montgomery-Åsberg Depression Rating Scale total score change, no significant dose-responses were observed for any candidate dose-response curve (all p>0.10). In the dose-response evaluable population, least squares mean (90% confidence interval) treatment differences versus placebo for Montgomery-Åsberg Depression Rating Scale total score change at week 16 were −1.4 (−3.9, 1.2), 0.1 (−2.5, 2.7), −0.7 (−3.4, 2.0), and −0.9 (−3.5, 1.6) with 10, 30, 50, and 70 mg lisdexamfetamine dimesylate, respectively. For all vital sign parameters, lisdexamfetamine dimesylate exhibited significant dose-responses for all candidate dose-response curves (all p<0.10), with increases observed as lisdexamfetamine dimesylate dose increased; a linear relationship provided the best fit. Mean±standard deviation changes from augmentation baseline for systolic and diastolic blood pressure and pulse at week 16/early termination were −0.7±9.90 and −0.3±7.24 mm Hg and 0.2±10.57 bpm with placebo and were 1.9±9.47 and 0.8±7.40 mm Hg and 3.6±9.74 bpm with lisdexamfetamine dimesylate (all doses combined). The safety and tolerability profile of lisdexamfetamine dimesylate was consistent with previous studies. Conclusions: Lisdexamfetamine dimesylate augmentation did not provide benefit over placebo in adults with inadequate responses to antidepressant monotherapy based on the assessed efficacy measures. PMID:28857719

  6. Multi-scale simulation of radiation damage accumulation and subsequent hardening in neutron-irradiated α-Fe

    DOE PAGES

    Dunn, Aaron; Dingreville, Remi; Capolungo, Laurent

    2015-11-27

    A hierarchical methodology is introduced to predict the effects of radiation damage and irradiation conditions on the yield stress and internal stress heterogeneity developments in polycrystalline α-Fe. Simulations of defect accumulation under displacement cascade damage conditions are performed using spatially resolved stochastic cluster dynamics. The resulting void and dislocation loop concentrations and average sizes are then input into a crystal plasticity formulation that accounts for the change in critical resolved shear stress due to the presence of radiation induced defects. The simulated polycrystalline tensile tests show a good match to experimental hardening data over a wide range of irradiation doses.more » With this capability, stress heterogeneity development and the effect of dose rate on hardening is investigated. The model predicts increased hardening at higher dose rates for low total doses. By contrast, at doses above 10 –2 dpa when cascade overlap becomes significant, the model does not predict significantly different hardening for different dose rates. In conclusion, the development of such a model enables simulation of radiation damage accumulation and associated hardening without relying on experimental data as an input under a wide range of irradiation conditions such as dose, dose rate, and temperature.« less

  7. Effect of ketamine dose on self-rated dissociation in patients with treatment refractory anxiety disorders.

    PubMed

    Castle, Cameron; Gray, Andrew; Neehoff, Shona; Glue, Paul

    2017-10-01

    Patients receiving ketamine for refractory depression and anxiety report dissociative symptoms in the first 60 min post-dose. The most commonly used instrument to assess this is the Clinician-Administered Dissociative States Scale (CADSS), developed based on the assessment of patients with dissociative symptoms. Its psychometric properties for ketamine-induced dissociation have not been reported. We evaluated these from a study using 0.25-1 mg/kg ketamine and midazolam (as an active control) in 18 patients with treatment-resistant anxiety. Dissociation ratings were increased by ketamine in a dose-dependent manner. In contrast, midazolam showed no effect on ratings of dissociation. For individual CADSS items, the magnitude of change and the ketamine dose at which changes were observed were not homogenous. The Cronbach alpha for the total scale was high (0.937), with acceptable item-rest correlations for almost all individual items. Purposefully removing items to maximise alpha did not lead to meaningful improvements. Acceptable internal consistency was still observed after removing items which lacked evidence of responsiveness at lower doses. The high Cronbach alpha values identified in this study suggests that the CADSS is an internally consistent instrument for evaluating ketamine-induced dissociation in clinical trials in anxiety, although it does not capture symptoms such as thought disorder.

  8. Seizure threshold increases can be predicted by EEG quality in right unilateral ultrabrief ECT.

    PubMed

    Gálvez, Verònica; Hadzi-Pavlovic, Dusan; Waite, Susan; Loo, Colleen K

    2017-12-01

    Increases in seizure threshold (ST) over a course of brief pulse ECT can be predicted by decreases in EEG quality, informing ECT dose adjustment to maintain adequate supra-threshold dosing. ST increases also occur over a course of right unilateral ultrabrief (RUL UB) ECT, but no data exist on the relationship between ST increases and EEG indices. This study (n = 35) investigated if increases in ST over RUL UB ECT treatments could be predicted by a decline in seizure quality. ST titration was performed at ECT session one and seven, with treatment dosing maintained stable (at 6-8 times ST) in intervening sessions. Seizure quality indices (slow-wave onset, mid-ictal amplitude, regularity, stereotypy, and post-ictal suppression) were manually rated at the first supra-threshold treatment, and last supra-threshold treatment before re-titration, using a structured rating scale, by a single trained rater blinded to the ECT session being rated. Twenty-one subjects (60%) had a ST increase. The association between ST changes and EEG quality indices was analysed by logistic regression, yielding a significant model (p < 0.001). Initial ST (p < 0.05) and percentage change in mid-ictal amplitude (p < 0.05) were significant predictors of change in ST. Percentage change in post-ictal suppression reached trend level significance (p = 0.065). Increases in ST over a RUL UB ECT course may be predicted by decreases in seizure quality, specifically decline in mid-ictal amplitude and potentially in post-ictal suppression. Such EEG indices may be able to inform when dose adjustments are necessary to maintain adequate supra-threshold dosing in RUL UB ECT.

  9. Dedicated high dose rate 192Ir brachytherapy radiation fields for in vitro cell exposures at variable source-target cell distances: killing of mammalian cells depends on temporal dose rate fluctuation

    NASA Astrophysics Data System (ADS)

    Veigel, Cornelia; Hartmann, Günther H.; Fritz, Peter; Debus, Jürgen; Weber, Klaus-Josef

    2017-02-01

    Afterloading brachytherapy is conducted by the stepwise movement of a radioactive source through surgically implanted applicator tubes where at predefined dwell positions calculated dwell times optimize spatial dose delivery with respect to a planned dose level. The temporal exposure pattern exhibits drastic fluctuations in dose rate at a given coordinate and within a single treatment session because of the discontinuous and repeated source movement into the target volume. This could potentially affect biological response. Therefore, mammalian cells were exposed as monolayers to a high dose rate 192Ir source by utilizing a dedicated irradiation device where the distance between a planar array of radioactive source positions and the plane of the cell monolayer could be varied from 2.5 mm to 40 mm, thus varying dose rate pattern for any chosen total dose. The Gammamed IIi afterloading system equipped with a nominal 370 GBq (10 Ci) 192-Ir source was used to irradiate V79 Chinese hamster lung fibroblasts from both confluent and from exponential growth phase with dose up to 12 Gy (at room temperature, total exposure not exceeding 1 h). For comparison, V79 cells were also exposed to 6 MV x-rays from a clinical linear accelerator (dose rate of 2.5 Gy min-1). As biological endpoint, cell survival was determined by standard colony forming assay. Dose measurements were conducted with a diamond detector (sensitive area 7.3 mm2), calibrated by means of 60Co radiation. Additionally, dose delivery was simulated by Monte Carlo calculations using the EGSnrc code system. The calculated secondary electron fluence spectra at the cell location did not indicate a significant change of radiation quality (i.e. higher linear energy transfer) at the lower distances. Clonogenic cell survival curves obtained after brachytherapy exhibited an altered biological response compared to x-rays which was characterized by a significant reduction of the survival curve shoulder when dose rate fluctuations were high. Therefore, also for the time scale of the present investigation, cellular effects of radiation are not invariant to the temporal pattern in dose rate. We propose that with high dose rate variation the cells activate less efficiently their DNA damage response than after continuous irradiation.

  10. Dependence of pentobarbital kinetics upon the dose of the drug and its pharmacodynamic effects.

    PubMed

    Kozlowski, K H; Szaykowski, A; Danysz, A

    1977-01-01

    Pentobarbital (PB), at dose range of 20--50 mg/kg, displays in rabbits non-linear, dose-dependent kinetics. Pharmacokinetics parameters of drug elimination depend largely upon the dose, while the distribution phase is dose-independent. The rate of disappearance of PB from the central compartment (plasma) decreases with the increase of the dose. The analysis of pharmacodynamic parameters has shown that this dose-dependent retardation of PB elimination is probably caused by an impairment of metabolic processes, resulting from disturbance of the circulatory system. A close correlation has been found between the hypotensive effect of PB and the elimination constant, k13, and also between the hypotensive effect and beta.Vd(extrap), a coefficient proportional to the rate of metabolism of PB [23, 29]. The results indicate the necessity of considering the changes in the functional state of the organism, related to the action of a drug, in pharmacokinetic studies.

  11. Evidence for the changing regimens of acetylcysteine.

    PubMed

    Chiew, Angela L; Isbister, Geoffrey K; Duffull, Stephen B; Buckley, Nicholas A

    2016-03-01

    Paracetamol overdose prior to the introduction of acetylcysteine was associated with significant morbidity. Acetylcysteine is now the mainstay of treatment for paracetamol poisoning and has effectively reduced rates of hepatotoxicity and death. The current three-bag intravenous regimen with an initial high loading dose was empirically derived four decades ago and has not changed since. This regimen is associated with a high rate of adverse effects due mainly to the high initial peak acetylcysteine concentration. Furthermore, there are concerns that the acetylcysteine concentration is not adequate for 'massive' overdoses and that the dose and duration may need to be altered. Various novel regimens have been proposed, looking to address these issues. Many of these modified regimens aim to decrease the rate of adverse reactions by slowing the loading dose and thereby decrease the peak concentration. We used a published population pharmacokinetic model of acetylcysteine to simulate these modified regimens. We determined mean peak and 20 h acetylcysteine concentrations and area under the under the plasma concentration-time curve to compare these regimens. Those regimens that resulted in a lower peak acetylcysteine concentration have been shown in studies to have a lower rate of adverse events. However, these studies were too small to show whether they are as effective as the traditional regimen. Further research is still needed to determine the optimum dose and duration of acetylcysteine that results in the fewest side-effects and treatment failures. Indeed, a more patient-tailored approach might be required, whereby the dose and duration are altered depending on the paracetamol dose ingested or paracetamol concentrations. © 2015 The British Pharmacological Society.

  12. Efficacy of tofacitinib in patients with rheumatoid arthritis stratified by background methotrexate dose group.

    PubMed

    Fleischmann, R; Mease, P J; Schwartzman, S; Hwang, L-J; Soma, K; Connell, C A; Takiya, L; Bananis, E

    2017-01-01

    Tofacitinib is an oral Janus kinase inhibitor for the treatment of rheumatoid arthritis (RA). This post hoc analysis investigated the effect of methotrexate (MTX) dose on the efficacy of tofacitinib in patients with RA. ORAL Scan (NCT00847613) was a 2-year, randomized, Phase 3 trial evaluating tofacitinib in MTX-inadequate responder (IR) patients with RA. Patients received tofacitinib 5 or 10 mg twice daily (BID), or placebo, with low (≤12.5 mg/week), moderate (>12.5 to <17.5 mg/week), or high (≥17.5 mg/week) stable background MTX. Efficacy endpoints (at months 3 and 6) included American College of Rheumatology (ACR) 20/50/70 response rates, and mean change from baseline in Clinical Disease Activity Index (CDAI), Disease Activity Score in 28 joints (DAS28)-4(erythrocyte sedimentation rate [ESR]), Health Assessment Questionnaire-Disability Index (HAQ-DI), and modified Total Sharp score. 797 patients were treated with tofacitinib 5 mg BID (N = 321), tofacitinib 10 mg BID (N = 316), or placebo (N = 160); 242, 333, and 222 patients received low, moderate, and high MTX doses, respectively. At months 3 and 6, ACR20/50/70 response rates were greater for both tofacitinib doses vs placebo across all MTX doses. At month 3, mean changes from baseline in CDAI and HAQ-DI were significantly greater for both tofacitinib doses vs placebo, irrespective of MTX category; improvements were maintained at month 6. Both tofacitinib doses demonstrated improvements in DAS28-4(ESR), and less structural progression vs placebo, across MTX doses at month 6. Tofacitinib plus MTX showed greater clinical and radiographic efficacy than placebo in MTX-IR patients with RA, regardless of MTX dose.

  13. Impact of High-Dose Vitamin D3 Supplementation in Patients with Crohn's Disease in Remission: A Pilot Randomized Double-Blind Controlled Study.

    PubMed

    Narula, Neeraj; Cooray, Mohan; Anglin, Rebecca; Muqtadir, Zack; Narula, Alisha; Marshall, John K

    2017-02-01

    To assess the tolerability and efficacy of high-dose vitamin D3 in patients with Crohn's disease (CD). This was a randomized, double-blind placebo-controlled trial of high-dose vitamin D3 at 10,000 IU daily (n = 18) compared to 1000 IU daily (n = 16) for 12 months in patients with CD in remission. The primary outcome was change in serum 25-hydroxy-vitamin D levels. Secondary outcomes included clinical relapse rates and changes in mood scores. High-dose vitamin D3 at 10,000 IU daily significantly improved 25-hydroxy-vitamin D levels from a mean of 73.5 nmol/L [standard deviation (SD) 11.7 nmol/L] to 160.8 nmol/L (SD 43.2 nmol/L) (p = 0.02). On an intention-to-treat basis, the rate of relapse was not significantly different between patients receiving low- and high-dose vitamin D3 (68.8 vs 33.3%, p = 0.0844). In per-protocol analysis, clinical relapse of Crohn's disease was less frequently observed in patients receiving a high dose (0/12 or 0%) compared to those receiving a low dose of 1000 IU daily (3/8 or 37.5%) (p = 0.049). Improvement in anxiety and depression scores and a good safety profile were observed in both groups treated with vitamin D3. Oral supplementation with high-dose vitamin D3 at 10,000 IU daily significantly improved serum 25-hydroxy-vitamin D levels. Rates of clinical relapse were similar between both groups. Larger studies using high-dose vitamin D3 for treatment of inflammatory bowel diseases are warranted. CLINICALTRIALS. NCT02615288.

  14. General Pharmacology of Artesunate, a Commonly used Antimalarial Drug:Effects on Central Nervous, Cardiovascular, and Respiratory System

    PubMed Central

    Lee, Hyang-Ae; Kim, Ki-Suk

    2010-01-01

    Artesunate, a semi-synthetic derivative of artemisinin, is used primarily as a treatment for malaria. Its effects on the central nervous system, general behavior, and cardiovascular, respiratory, and other organ systems were studied using mice, rats, guinea pigs, and dogs. Artesunate was administered orally to mice at doses of 125, 250, and 500 mg/kg and to rats and guinea pigs at 100, 200, and 400 mg/kg. In dogs, test drugs were administered orally in gelatin capsules at doses of 50, 100, and 150 mg/kg. Artesunate induced insignificant changes in general pharmacological studies, including general behavior, motor coordination, body temperature, analgesia, convulsion modulation, blood pressure, heart rate (HR) , and electrocardiogram (ECG) in dogs in vivo; respiration in guinea pigs; and gut motility or direct effects on isolated guinea pig ileum, contractile responses, and renal function. On the other hand, artesunate decreased the HR and coronary flow rate (CFR) in the rat in vitro; however, the extent of the changes was small and they were not confirmed in in vivo studies in the dog. Artesunate increased hexobarbital-induced sleeping time in a dose-related manner. Artesunate induced dose-related decreases in the volume of gastric secretions and the total acidity of gastric contents, and induced increases in pH at a dose of 400 mg/kg. However, all of these changes were observed at doses much greater than clinical therapeutic doses (2.4 mg/kg in humans, when used as an anti-malarial) . Thus, it can be concluded that artesunate is safe at clinical therapeutic doses. PMID:24278528

  15. Effect of Remediation Parameters on in-Air Ambient Dose Equivalent Rates When Remediating Open Sites with Radiocesium-contaminated Soil.

    PubMed

    Malins, Alex; Kurikami, Hiroshi; Kitamura, Akihiro; Machida, Masahiko

    2016-10-01

    Calculations are reported for ambient dose equivalent rates [H˙*(10)] at 1 m height above the ground surface before and after remediating radiocesium-contaminated soil at wide and open sites. The results establish how the change in H˙*(10) upon remediation depends on the initial depth distribution of radiocesium within the ground, on the size of the remediated area, and on the mass per unit area of remediated soil. The remediation strategies considered were topsoil removal (with and without recovering with a clean soil layer), interchanging a topsoil layer with a subsoil layer, and in situ mixing of the topsoil. The results show the ratio of the radiocesium components of H˙*(10) post-remediation relative to their initial values (residual dose factors). It is possible to use the residual dose factors to gauge absolute changes in H˙*(10) upon remediation. The dependency of the residual dose factors on the number of years elapsed after fallout deposition is analyzed when remediation parameters remain fixed and radiocesium undergoes typical downward migration within the soil column.

  16. Systemic Effects of Intracoronary Nitroglycerin during Coronary Angiography in Children after Heart Transplantation

    PubMed Central

    Lara, Diego A.; Olive, Mary K.; George, James F.; Brown, Robert N.; Carlo, Waldemar F.; Colvin, Edward V.; Steenwyck, Brad L.

    2014-01-01

    Coronary spasm during coronary angiography for vasculopathy in children can be prevented by the intracoronary administration of nitroglycerin. We reviewed the anesthesia and catheterization reports and charts for pediatric transplant recipients who underwent angiography from 2005 through 2010. Correlation analysis was used to study the relation of post-injection systolic blood pressure (SBP) to nitroglycerin dose. Forty-one angiographic evaluations were performed on 25 patients (13 male and 12 female). Mean age was 9.9 ± 3.2 years (range, 3.3–16.1 yr). The mean total dose of nitroglycerin was 2.93 ± 1.60 µg/kg (range, 1–8 µg/kg). There was a significant drop between the baseline SBP (mean, 106 ± 21.6 mmHg) and the lowest mean SBP before nitroglycerin administration (78 ± 13.2, P <0.0001, paired t test). There was no significant additional change in SBP (mean after nitroglycerin administration, 80.7 ± 13.1 mmHg; P = 0.2). There was a significant drop in lowest heart rate between baseline (109 ± 16.5 beats/min) and before nitroglycerin administration (89 ± 14.3 beats/min; P <0.0001, paired t test). There was no significant additional change in heart rate (mean heart rate after nitroglycerin, 84 ± 17.7 beats/min; P = 0.09). There were 2 interventions for SBP before nitroglycerin and 2 after nitroglycerin. One child experienced a transient ST-T–segment change during angiography after nitroglycerin. In the highest dose range, the additional decrease in SBP was 7.2 mmHg (P=0.03). Routine intracoronary nitroglycerin administration in this dose range produced no significant changes in SBP or heart rate in children. PMID:24512395

  17. Systemic effects of intracoronary nitroglycerin during coronary angiography in children after heart transplantation.

    PubMed

    Lara, Diego A; Olive, Mary K; George, James F; Brown, Robert N; Carlo, Waldemar F; Colvin, Edward V; Steenwyck, Brad L; Pearce, F Bennett

    2014-02-01

    Coronary spasm during coronary angiography for vasculopathy in children can be prevented by the intracoronary administration of nitroglycerin. We reviewed the anesthesia and catheterization reports and charts for pediatric transplant recipients who underwent angiography from 2005 through 2010. Correlation analysis was used to study the relation of post-injection systolic blood pressure (SBP) to nitroglycerin dose. Forty-one angiographic evaluations were performed on 25 patients (13 male and 12 female). Mean age was 9.9 ± 3.2 years (range, 3.3-16.1 yr). The mean total dose of nitroglycerin was 2.93 ± 1.60 µg/kg (range, 1-8 µg/kg). There was a significant drop between the baseline SBP (mean, 106 ± 21.6 mmHg) and the lowest mean SBP before nitroglycerin administration (78 ± 13.2, P <0.0001, paired t test). There was no significant additional change in SBP (mean after nitroglycerin administration, 80.7 ± 13.1 mmHg; P = 0.2). There was a significant drop in lowest heart rate between baseline (109 ± 16.5 beats/min) and before nitroglycerin administration (89 ± 14.3 beats/min; P <0.0001, paired t test). There was no significant additional change in heart rate (mean heart rate after nitroglycerin, 84 ± 17.7 beats/min; P = 0.09). There were 2 interventions for SBP before nitroglycerin and 2 after nitroglycerin. One child experienced a transient ST-T-segment change during angiography after nitroglycerin. In the highest dose range, the additional decrease in SBP was 7.2 mmHg (P=0.03). Routine intracoronary nitroglycerin administration in this dose range produced no significant changes in SBP or heart rate in children.

  18. 'Real-life' study of imatinib therapy in chronic phase-chronic myeloid leukemia: A novel retrospective observational longitudinal analysis.

    PubMed

    Merante, Serena; Ferretti, Virginia; Elena, Chiara; Calvello, Celeste; Rocca, Barbara; Zappatore, Rita; Cavigliano, Paola; Orlandi, Ester

    2017-01-01

    Imatinib is a cornerstone of treatment of chronic myeloid leukemia. It remains unclear whether transient treatment discontinuation or dose changes affect outcome and this approach has not yet been approved for use outside clinical trials. We conducted a retrospective single-institution observational study to evaluate factors affecting response in 'real-life' clinical practice in 138 chronic myeloid leukemia patients in chronic phase treated with imatinib. We used a novel longitudinal data analytical model, with a generalized estimating equation model, to study BCR-ABL variation according to continuous standard dose, change in dose or discontinuation; BCR-ABL transcript levels were recorded. Treatment history was subdivided into time periods for which treatment was given at constant dosage (total 483 time periods). Molecular and cytogenetic complete response was observed after 154 (32%) and 358 (74%) time periods, respectively. After adjusting for length of time period, no association between dose and cytogenetic complete response rate was observed. There was a significantly lower molecular complete response rate after time periods at a high imatinib dosage. This statistical approach can identify individual patient variation in longitudinal data collected over time and suggests that changes in dose or discontinuation of therapy could be considered in patients with appropriate biological characteristics.

  19. A dose-response study of dexmedetomidine administered as the primary sedative in infants following open heart surgery.

    PubMed

    Su, Felice; Nicolson, Susan C; Zuppa, Athena F

    2013-06-01

    To evaluate the dose-response relationship of dexmedetomidine in infants with congenital heart disease postoperative from open heart surgery. Prospective open-label dose-escalation pharmacokinetic-pharmacodynamic study. Tertiary pediatric cardiac ICU. Thirty-six evaluable infants, 1-24 months old, postoperative from open heart surgery requiring mechanical ventilation. Cohorts of 12 infants were enrolled sequentially to one of the three IV loading doses of dexmedetomidine (0.35, 0.7, and 1 mcg/kg) over 10 minutes followed by respective continuous infusions (0.25, 0.5, and 0.75 mcg/kg/hr) for up to 24 hours. Dexmedetomidine plasma concentrations were obtained at timed intervals during and following discontinuation of infusion. Pharmacodynamic variables evaluated included sedation scores, supplemental sedation and analgesia medication administration, time to tracheal extubation, respiratory function, and hemodynamic parameters. Infants achieved a deeper sedation measured by the University of Michigan Sedation Scale score (2.6 vs 1) despite requiring minimal supplemental sedation (0 unit doses/hr) and fewer analgesic medications (0.07 vs 0.15 unit doses/hr) while receiving dexmedetomidine compared with the 12-hour follow-up period. Thirty-one patients were successfully extubated while receiving the dexmedetomidine infusion. Only one patient remained intubated due to oversedation during the infusion. While receiving dexmedetomidine, there was a decrease in heart rate compared with baseline, 132 versus 161 bpm, but there was an increase in heart rate compared with postinfusion values, 132 versus 128 bpm. There was no statistically or clinically significant change in mean arterial blood pressure. Dexmedetomidine administration in infants following open heart surgery can provide improved sedation with reduction in supplemental medication requirements, leading to successful extubation while receiving a continuous infusion. The postoperative hemodynamic changes that occur in infants postoperative from open heart surgery are multifactorial. Although dexmedetomidine may play a role in decreasing heart rate immediately postoperative, the changes were not clinically significant and did not fall below postinfusion heart rates.

  20. Preliminary Shielding Analysis for HCCB TBM Transport

    NASA Astrophysics Data System (ADS)

    Miao, Peng; Zhao, Fengchao; Cao, Qixiang; Zhang, Guoshu; Feng, Kaiming

    2015-09-01

    A preliminary shielding analysis on the transport of the Chinese helium cooled ceramic breeder test blanket module (HCCB TBM) from France back to China after being irradiated in ITER is presented in this contribution. Emphasis was placed on irradiation safety during transport. The dose rate calculated by MCNP/4C for the conceptual package design satisfies the relevant dose limits from IAEA that the dose rate 3 m away from the surface of the package containing low specific activity III materials should be less than 10 mSv/h. The change with location and the time evolution of dose rates after shutdown have also been studied. This will be helpful for devising the detailed transport plan of HCCB TBM back to China in the near future. supported by the Major State Basic Research Development Program of China (973 Program) (No. 2013GB108000)

  1. γ irradiation with different dose rates induces different DNA damage responses in Petunia x hybrida cells.

    PubMed

    Donà, Mattia; Ventura, Lorenzo; Macovei, Anca; Confalonieri, Massimo; Savio, Monica; Giovannini, Annalisa; Carbonera, Daniela; Balestrazzi, Alma

    2013-05-15

    In plants, there is evidence that different dose rate exposures to gamma (γ) rays can cause different biological effects. The dynamics of DNA damage accumulation and molecular mechanisms that regulate recovery from radiation injury as a function of dose rate are poorly explored. To highlight dose-rate dependent differences in DNA damage, single cell gel electrophoresis was carried out on regenerating Petunia x hybrida leaf discs exposed to LDR (total dose 50 Gy, delivered at 0.33 Gy min(-1)) and HDR (total doses 50 and 100 Gy, delivered at 5.15 Gy min(-1)) γ-ray in the 0-24h time period after treatments. Significant fluctuations of double strand breaks and different repair capacities were observed between treatments in the 0-4h time period following irradiation. Dose-rate-dependent changes in the expression of the PhMT2 and PhAPX genes encoding a type 2 metallothionein and the cytosolic isoform of ascorbate peroxidase, respectively, were detected by Quantitative RealTime-Polymerase Chain Reaction. The PhMT2 and PhAPX genes were significantly up-regulated (3.0- and 0.7-fold) in response to HDR. The results are discussed in light of the potential practical applications of LDR-based treatments in mutation breeding. Copyright © 2013 Elsevier GmbH. All rights reserved.

  2. Dactinomycin and Vincristine Toxicity in the Treatment of Childhood Cancer: A Retrospective Study from the Children’s Oncology Group

    PubMed Central

    Langholz, Bryan; Skolnik, Jeffrey M.; Barrett, Jeffrey S.; Renbarger, Jamie; Seibel, Nita L.; Zajicek, Anne; Arndt, Carola A.S.

    2011-01-01

    Background Dactinomycin (AMD) and vincristine (VCR) have been used for the treatment of childhood cancer over the past 40 years but evidence-based dosing guidance is lacking. Methods Patient AMD and VCR dose and drug-related adverse event (AE) information from four rhabdomyosarcoma (RMS) and two Wilms tumor (WT) studies were assembled. Statistical modeling was used to account for differences in AE data collection across studies, develop rate models for grade 3/4 CTCAE v3 hepatic- (AMD) and neuro- (AMD) toxicity, assess variation in toxicity rates over age and other factors, and predict toxicity risk under current dosing guidelines. Results For the same dose/body size, AMD toxicity rates were higher in patients <1 year than older patients and VCR toxicity rates increased with age. The statistical model provided estimates for AMD and VCR toxicity risk under current dosing schedules and indicated that patients of smaller body size were at lower risk of VCR toxicity than larger patients of the same age. The rate of AMD toxicity was highest early in treatment and was lower in patients who tolerated initial AMD without toxicity. Conclusion The observed decrease in AMD toxicity rate with cumulative dose may indicate sensitivity in a subgroup of patients while the observed increase in VCR toxicity risk with age may indicate changing sensitivity to VCR. Current dosing practices result in a fairly uniform toxicity profile within age group. However, PK/PD studies should be done to provide further provide further information on best dosing guidelines. PMID:21671362

  3. The clinical significance of 5% change in vital capacity in patients with idiopathic pulmonary fibrosis: extended analysis of the pirfenidone trial

    PubMed Central

    2011-01-01

    Background Our phase III clinical trial of pirfenidone for patients with idiopathic pulmonary fibrosis (IPF) revealed the efficacy in reducing the decline of vital capacity (VC) and increasing the progression-free survival (PFS) time by pirfenidone. Recently, marginal decline in forced VC (FVC) has been reported to be associated with poor outcome in IPF. We sought to evaluate the efficacy of pirfenidone from the aspects of 5% change in VC. Methods Improvement ratings based on 5% change in absolute VC, i.e., "improved (VC ≥ 5% increase)", "stable (VC < 5% change)", and "worsened (VC ≥ 5% decrease)" at month 3, 6, 9 and 12 were compared between high-dose pirfenidone (1800 mg/day; n = 108) and placebo (n = 104) groups, and (high-dose and low-dose (1200 mg/day; n = 55)) pirfenidone (n = 163) and placebo groups. PFS times with defining the disease progression as death or a ≥ 5% decline in VC were also compared between high-dose pirfenidone and placebo groups, and low-dose pirfenidone and placebo groups. Furthermore, considering "worsened" and "non-worsened (improved and stable)" of the ratings at months 3 and 12 as "positive" and "negative", respectively, and the positive and negative predictive values of the ratings were calculated in each group. Results In the comparison of the improvement ratings, the statistically significant differences were clearly revealed at months 3, 6, 9, and 12 between pirfenidone and placebo groups. Risk reductions by pirfenidone to placebo were approximately 35% over the study period. In the comparison of the PFS times, statistically significant difference was also observed between pirfenidone and placebo groups. The positive/negative predictive values in placebo and pirfenidone groups were 86.1%/50.8% and 87.1%/71.7%, respectively. Further, the baseline characteristics of patients worsened at month 3 had generally severe impairment, and their clinical outcomes including mortality were also significantly worsened after 1 year. Conclusions The efficacy of pirfenidone in Japanese phase III trial was supported by the rating of 5% decline in VC, and the VC changes at month 3 may be used as a prognostic factor of IPF. Trial Registration This clinical trial was registered with the Japan Pharmaceutical Information Center (JAPIC) on September 13th, 2005 (Registration Number: JAPICCTI-050121). PMID:21756364

  4. Sub-dissociative dose intranasal ketamine for limb injury pain in children in the emergency department: a pilot study.

    PubMed

    Yeaman, Fiona; Oakley, Ed; Meek, Robert; Graudins, Andis

    2013-04-01

    The present study aims to conduct a pilot study examining the effectiveness of intranasal (IN) ketamine as an analgesic for children in the ED. The present study used an observational study on a convenience sample of paediatric ED patients aged 3-13 years, with moderate to severe (≥6/10) pain from isolated limb injury. IN ketamine was administered at enrolment, with a supplementary dose after 15 min, if required. Primary outcome was change in median pain rating at 30 min. Secondary outcomes included change in median pain rating at 60 min, patient/parent satisfaction, need for additional analgesia and adverse events being reported. For the 28 children included in the primary analysis, median age was 9 years (interquartile range [IQR] 6-10). Twenty-three (82.1%) were male. Eighteen (64%) received only one dose of IN ketamine (mean dose 0.84 mg/kg), whereas 10 (36%) required a second dose at 15 min (mean for second dose 0.54 mg/kg). The total mean dose for all patients was 1.0 mg/kg (95% CI: 0.92-1.14). The median pain rating decreased from 74.5 mm (IQR 60-85) to 30 mm (IQR 12-51.5) at 30 min (P < 0.001, Mann-Whitney). For the 24 children who contributed data at 60 min, the median pain rating was 25 mm (IQR 4-44). Twenty (83%) subjects were satisfied with their analgesia. Eight (33%) were given additional opioid analgesia and the 28 reported adverse events were all transient and mild. In this population, an average dose of 1.0 mg/kg IN ketamine provided adequate analgesia by 30 min for most patients. © 2013 The Authors. EMA © 2013 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  5. Psilocybin occasioned mystical-type experiences: immediate and persisting dose-related effects.

    PubMed

    Griffiths, Roland R; Johnson, Matthew W; Richards, William A; Richards, Brian D; McCann, Una; Jesse, Robert

    2011-12-01

    This dose-effect study extends previous observations showing that psilocybin can occasion mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. This double-blind study evaluated psilocybin (0, 5, 10, 20, 30 mg/70 kg, p.o.) administered under supportive conditions. Participants were 18 adults (17 hallucinogen-naïve). Five 8-h sessions were conducted individually for each participant at 1-month intervals. Participants were randomized to receive the four active doses in either ascending or descending order (nine participants each). Placebo was scheduled quasi-randomly. During sessions, volunteers used eyeshades and were instructed to direct their attention inward. Volunteers completed questionnaires assessing effects immediately after and 1 month after each session, and at 14 months follow-up. Psilocybin produced acute perceptual and subjective effects including, at 20 and/or 30 mg/70 kg, extreme anxiety/fear (39% of volunteers) and/or mystical-type experience (72% of volunteers). One month after sessions at the two highest doses, volunteers rated the psilocybin experience as having substantial personal and spiritual significance, and attributed to the experience sustained positive changes in attitudes, mood, and behavior, with the ascending dose sequence showing greater positive effects. At 14 months, ratings were undiminished and were consistent with changes rated by community observers. Both the acute and persisting effects of psilocybin were generally a monotonically increasing function of dose, with the lowest dose showing significant effects. Under supportive conditions, 20 and 30 mg/70 kg psilocybin occasioned mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. Implications for therapeutic trials are discussed.

  6. Higher dose rate Gamma Knife radiosurgery may provide earlier and longer-lasting pain relief for patients with trigeminal neuralgia.

    PubMed

    Lee, John Y K; Sandhu, Sukhmeet; Miller, Denise; Solberg, Timothy; Dorsey, Jay F; Alonso-Basanta, Michelle

    2015-10-01

    Gamma Knife radiosurgery (GKRS) utilizes cobalt-60 as its radiation source, and thus dose rate varies as the fixed source decays over its half-life of approximately 5.26 years. This natural decay results in increasing treatment times when delivering the same cumulative dose. It is also possible, however, that the biological effective dose may change based on this dose rate even if the total dose is kept constant. Because patients are generally treated in a uniform manner, radiosurgery for trigeminal neuralgia (TN) represents a clinical model whereby biological efficacy can be tested. The authors hypothesized that higher dose rates would result in earlier and more complete pain relief but only if measured with a sensitive pain assessment tool. One hundred thirty-three patients were treated with the Gamma Knife Model 4C unit at a single center by a single neurosurgeon during a single cobalt life cycle from January 2006 to May 2012. All patients were treated with 80 Gy with a single 4-mm isocenter without blocking. Using an output factor of 0.87, dose rates ranged from 1.28 to 2.95 Gy/min. The Brief Pain Inventory (BPI)-Facial was administered before the procedure and at the first follow-up office visit 1 month from the procedure (mean 1.3 months). Phone calls were made to evaluate patients after their procedures as part of a retrospective study. Univariate and multivariate linear regression was performed on several independent variables, including sex, age in deciles, diagnosis, follow-up duration, prior surgery, and dose rate. In the short-term analysis (mean 1.3 months), patients' self-reported pain intensity at its worst was significantly correlated with dose rate on multivariate analysis (p = 0.028). Similarly, patients' self-reported interference with activities of daily living was closely correlated with dose rate on multivariate analysis (p = 0.067). A 1 Gy/min decrease in dose rate resulted in a 17% decrease in pain intensity at its worst and a 22% decrease in pain interference with activities of daily living. In longer-term follow-up (mean 1.9 years), GKRS with higher dose rates (> 2.0 Gy/min; p = 0.007) and older age in deciles (p = 0.012) were associated with a lower likelihood of recurrence of pain. Prior studies investigating the role of dose rate in Gamma Knife radiosurgical ablation for TN have not used validated outcome tools to measure pain preoperatively. Consequently, differences in pain outcomes have been difficult to measure. By administering pain scales both preoperatively as well as postoperatively, the authors have identified statistically significant differences in pain intensity and pain interference with activities of daily living when comparing higher versus lower dose rates. Radiosurgery with a higher dose rate results in more pain relief at the early follow-up evaluation, and it may result in a lower recurrence rate at later follow-up.

  7. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 2. How a mistake led BEIR I to adopt LNT.

    PubMed

    Calabrese, Edward J

    2017-04-01

    This paper reveals that nearly 25 years after the National Academy of Sciences (NAS), Biological Effects of Ionizing Radiation (BEIR) I Committee (1972) used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Critical target and dose and dose-rate responses for the induction of chromosomal instability by ionizing radiation

    NASA Technical Reports Server (NTRS)

    Limoli, C. L.; Corcoran, J. J.; Milligan, J. R.; Ward, J. F.; Morgan, W. F.

    1999-01-01

    To investigate the critical target, dose response and dose-rate response for the induction of chromosomal instability by ionizing radiation, bromodeoxyuridine (BrdU)-substituted and unsubstituted GM10115 cells were exposed to a range of doses (0.1-10 Gy) and different dose rates (0.092-17.45 Gy min(-1)). The status of chromosomal stability was determined by fluorescence in situ hybridization approximately 20 generations after irradiation in clonal populations derived from single progenitor cells surviving acute exposure. Overall, nearly 700 individual clones representing over 140,000 metaphases were analyzed. In cells unsubstituted with BrdU, a dose response was found, where the probability of observing delayed chromosomal instability in any given clone was 3% per gray of X rays. For cells substituted with 25-66% BrdU, however, a dose response was observed only at low doses (<1.0 Gy); at higher doses (>1.0 Gy), the incidence of chromosomal instability leveled off. There was an increase in the frequency and complexity of chromosomal instability per unit dose compared to cells unsubstituted with BrdU. The frequency of chromosomal instability appeared to saturate around approximately 30%, an effect which occurred at much lower doses in the presence of BrdU. Changing the gamma-ray dose rate by a factor of 190 (0.092 to 17.45 Gy min(-1)) produced no significant differences in the frequency of chromosomal instability. The enhancement of chromosomal instability promoted by the presence of the BrdU argues that DNA comprises at least one of the critical targets important for the induction of this end point of genomic instability.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, P.H.; Krishnamurthy, G.T.; Bobba, V.R.

    The radiation absorbed doses from five commercially available hepatobiliary agents-Tc-99m-tagged analogs of IDA (EIDA, PIPIDA, HIDA, PBIDA, DISIDA*) have been calculated from biokinetic data in 41 normal subjects. Serial gamma images, with blood and urine samples, were obtained to calculate cumulated radioactivity in the source organs: blood, kidey, bladder, liver, gallbladder, and intestines. The critical organ was the gallbladder, with an absorbed-dose range of 690 to 780 mrad/mCi. Absorbed doses for other target organs were: upper large intestine 320 to 370 mrad/mCi, lower large intestine 210 to 240, small intestine 170 to 200, liver 65 (DISIDA) to 130 (PBIDA), ovariesmore » 63 to 72, and urinary bladder wall 23 (PBIDA) to 36 (EIDA). The radiation absorbed dose was largely independent of changes in chemical structure except in (a) the liver, where absorbed dose varied by a factor of two in proportion to the rate of excretion of the IDA agent from the liver, and (b) the urinary bladder, where absorbed dose varied by a factor of 1.6 because of differences in rate of excretion. When the stimulus for gallbladder emptying is changed from whole-meal ingestion to cholecystokinin injection, the absorbed dose to the gallbladder increases to approx. 1 rad/mCi; if no gallbladder emptying is assumed, its absorbed dose increases to approx. 1.9 rad/mCi. In the absence of contraindication, the gallbladder absorbed dose may thus be decreased by inducing gallbladder emptying at the end of the imaging study.« less

  10. Effects of Epoetin Alfa Titration Practices, Implemented After Changes to Product Labeling, on Hemoglobin Levels, Transfusion Use, and Hospitalization Rates.

    PubMed

    Molony, Julia T; Monda, Keri L; Li, Suying; Beaubrun, Anne C; Gilbertson, David T; Bradbury, Brian D; Collins, Allan J

    2016-08-01

    Little is known about epoetin alfa (EPO) dosing at dialysis centers after implementation of the US Medicare prospective payment system and revision of the EPO label in 2011. Retrospective cohort study. Approximately 412,000 adult hemodialysis patients with Medicare Parts A and B as primary payer in 2009 to 2012 to describe EPO dosing and hemoglobin patterns; of these, about 70,000 patients clustered in about 1,300 dialysis facilities to evaluate facility-level EPO titration practices and patient-level outcomes in 2012. Facility EPO titration practices when hemoglobin levels were <10 and >11g/dL (grouped treatment variable) determined from monthly EPO dosing and hemoglobin level patterns. Patient mean hemoglobin levels, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates using a facility-based analysis. Monthly EPO dose and hemoglobin level, red blood cell transfusion rates, and all-cause and cause-specific hospitalization rates. Monthly EPO doses declined across all hemoglobin levels, with the greatest decline in patients with hemoglobin levels < 10g/dL (July-October 2011). In 2012, nine distinct facility titration practices were identified. Across groups, mean hemoglobin levels differed slightly (10.5-10.8g/dL) but within-patient hemoglobin standard deviations were similar (∼0.68g/dL). Patients at facilities implementing greater dose reductions and smaller dose escalations had lower hemoglobin levels and higher transfusion rates. In contrast, patients at facilities that implemented greater dose escalations (and large or small dose reductions) had higher hemoglobin levels and lower transfusion rates. There were no clinically meaningful differences in all-cause or cause-specific hospitalization events across groups. Possibly incomplete claims data; excluded small facilities and those without consistent titration patterns; hemoglobin levels reported monthly; inferred facility practice from observed dosing. Following prospective payment system implementation and labeling revisions, EPO doses declined significantly. Under the new label, facility EPO titration practices were associated with mean hemoglobin levels (but not standard deviations) and transfusion use, but not hospitalization rates. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  11. Factors modifying the response of large animals to low-intensity radiation exposure

    NASA Technical Reports Server (NTRS)

    Page, N. P.; Still, E. T.

    1972-01-01

    In assessing the biological response to space radiation, two of the most important modifying factors are dose protraction and dose distribution to the body. Studies are reported in which sheep and swine were used to compare the hematology and lethality response resulting from radiation exposure encountered in a variety of forms, including acute (high dose-rate), chronic (low dose-rate), combinations of acute and chronic, and whether received as a continuous or as fractionated exposure. While sheep and swine are basically similar in response to acute radiation, their sensitivity to chronic irradiation is markedly different. Sheep remain relatively sensitive as the radiation exposure is protracted while swine are more resistant and capable of surviving extremely large doses of chronic irradiation. This response to chronic irradiation correlated well with changes in radiosensitivity and recovery following an acute, sublethal exposure.

  12. Change in Practice over Four Decades in the Management of Graves' Disease in Scotland.

    PubMed

    Smith, D M; Dutta, S; Ahmed, F; Thaha, M A

    2016-01-01

    There is continuing debate on the optimal treatment for Grave's thyrotoxicosis with a resultant variation in clinical practice. The present study aimed to ascertain changes in practice in the treatment of Grave's thyrotoxicosis in Tayside, Scotland, over the past four decades. Methods. The "Scottish automated follow-up register" (SAFUR) was queried to identify all patients treated for Grave's thyrotoxicosis from 1968 to 2007 inclusive. Patients were divided into 4 groups (Groups A to D) according to the decades. Demographic profile, treatment modalities, radioactive iodine (RAI) dose, and recurrence rates were studied and outcomes were compared by χ (2) test and ANOVA using SPSS v15.0. A p value of < 0.05 was considered significant. Results. Altogether, 3737 patients were diagnosed with Grave's thyrotoxicosis over the 4 decades. Use of RAI has increased from 43.1% in Group A to 68% in Group D (p < 0.001). The dose of RAI has increased (p < 0.001) and there has been a reduction in recurrence rate with higher dose of RAI. Surgical intervention rates decreased from 55.3% to 12.3% (p < 0.001) over time. Conclusions. Analysis of a large dataset of patients with Grave's thyrotoxicosis suggests increasing use of RAI as the preferred first line of treatment. Furthermore, using a single higher dose of RAI and adoption of total thyroidectomy have decreased recurrence rates.

  13. Change in Practice over Four Decades in the Management of Graves' Disease in Scotland

    PubMed Central

    Smith, D. M.; Dutta, S.; Ahmed, F.; Thaha, M. A.

    2016-01-01

    There is continuing debate on the optimal treatment for Grave's thyrotoxicosis with a resultant variation in clinical practice. The present study aimed to ascertain changes in practice in the treatment of Grave's thyrotoxicosis in Tayside, Scotland, over the past four decades. Methods. The “Scottish automated follow-up register” (SAFUR) was queried to identify all patients treated for Grave's thyrotoxicosis from 1968 to 2007 inclusive. Patients were divided into 4 groups (Groups A to D) according to the decades. Demographic profile, treatment modalities, radioactive iodine (RAI) dose, and recurrence rates were studied and outcomes were compared by χ 2 test and ANOVA using SPSS v15.0. A p value of < 0.05 was considered significant. Results. Altogether, 3737 patients were diagnosed with Grave's thyrotoxicosis over the 4 decades. Use of RAI has increased from 43.1% in Group A to 68% in Group D (p < 0.001). The dose of RAI has increased (p < 0.001) and there has been a reduction in recurrence rate with higher dose of RAI. Surgical intervention rates decreased from 55.3% to 12.3% (p < 0.001) over time. Conclusions. Analysis of a large dataset of patients with Grave's thyrotoxicosis suggests increasing use of RAI as the preferred first line of treatment. Furthermore, using a single higher dose of RAI and adoption of total thyroidectomy have decreased recurrence rates. PMID:27313946

  14. Long-term changes of renal function in relation to ace inhibitor/angiotensin receptor blocker dosing in patients with heart failure and chronic kidney disease.

    PubMed

    Fröhlich, Hanna; Nelges, Christoph; Täger, Tobias; Schwenger, Vedat; Cebola, Rita; Schnorbach, Johannes; Goode, Kevin M; Kazmi, Syed; Katus, Hugo A; Cleland, John G F; Clark, Andrew L; Frankenstein, Lutz

    2016-08-01

    Angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) have become cornerstones of therapy for chronic heart failure (CHF). Guidelines advise high target doses for ACEIs/ARBs, but fear of worsening renal function may limit dose titration in patients with concomitant chronic kidney disease (CKD). In this retrospective observational study, we identified 722 consecutive patients with systolic CHF, stable CKD stage III/IV (estimated glomerular filtration rate [eGFR] 15-60 mL min(-1) 1.73 m(-2)) and chronic ACEI/ARB treatment from the outpatient heart failure clinics at the Universities of Hull, UK, and Heidelberg, Germany. Change of renal function, worsening CHF, and hyperkalemia at 12-month follow-up were analyzed as a function of both baseline ACEI/ARB dose and dose change from baseline. ΔeGFR was not related to baseline dose of ACEI/ARB (P = .58), or to relative (P = .18) or absolute change of ACEI/ARB dose (P = .21) during follow-up. Expressing change of renal function as a categorical variable (improved/stable/decreased) as well as subgroup analyses with respect to age, sex, New York Heart Association functional class, left ventricular ejection fraction, diabetes, concomitant aldosterone antagonists, CKD stage, hypertension, ACEI vs ARB, and congestion status yielded similar results. There was no association of dose/dose change with incidence of either worsening CHF or hyperkalemia. In patients with systolic CHF and stable CKD stage III/IV, neither continuation of high doses of ACEI/ARB nor up-titration was related to adverse changes in longer-term renal function. Conversely, down-titration was not associated with improvement in eGFR. Use of high doses of ACEI/ARB and their up-titration in patients with CHF and CKD III/IV may be appropriate provided that the patient is adequately monitored. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Alternative Reinforcer Response Cost Impacts Methamphetamine Choice in Humans

    PubMed Central

    Bennett, J. Adam; Stoops, William W.; Rush, Craig R.

    2012-01-01

    Methamphetamine use disorders are a persistent public health concern. Behavioral treatments have demonstrated that providing access to non-drug alternative reinforcers reduces methamphetamine use. The purpose of this human laboratory experiment was to determine how changes in response cost for non-drug alternative reinforcers influenced methamphetamine choice. Seven subjects with past year histories of recreational stimulant use completed a placebo-controlled, crossover, double-blind protocol in which they first sampled doses of oral methamphetamine (0, 8 or 16 mg) and completed a battery of subject-rated and physiological measures. During subsequent sessions, subjects then made eight discrete choices between 1/8th of the sampled dose and an alternative reinforcer ($0.25). The response cost to earn a methamphetamine dose was always 500 responses (FR500). The response cost for the alternative reinforcer varied across sessions (FR500, FR1000, FR2000, FR3000). Methamphetamine functioned as a positive reinforcer and produced prototypical stimulant-like effects (e.g., elevated blood pressure, increased ratings of “Stimulated”). Choice for doses over money was sensitive to changes in response cost for alternative reinforcers in that more doses were taken at higher FR values than at lower FR values. Placebo choices changed as a function of alternative reinforcer response cost to a greater degree than active methamphetamine choices. These findings suggest that manipulating the effort necessary to earn alternative reinforcers could impact methamphetamine use. PMID:23046851

  16. Action research regarding the optimisation of radiological protection for nurses during vascular interventional radiology.

    PubMed

    Mori, Hiroshige

    2015-06-01

    The optimisation and decision-making processes for radiological protection have been broadened by the introduction of re-examination or feedback after introducing protective measures. In this study, action research was used to reduce the occupational exposure of vascular interventional radiology (IR) nurses. Four radiological protection improvement measures were continuously performed in cooperation with the researchers, nurses and stakeholders, and the nurses' annual effective doses were compared before and after the improvements. First, the dosimetry equipment was changed from one electronic personal dosimeter (EPD) to two silver-activated phosphate glass dosimeters (PGDs). Second, the nurses were educated regarding maintaining a safe distance from the sources of scattered and leakage radiation. Third, portable radiation shielding screens were placed in the IR rooms. Fourth, the x-ray units' pulse rates were reduced by half. On changing the dosimetry method, the two PGDs recorded a 4.4 fold greater dose than the single EPD. Educating nurses regarding radiological protection and reducing the pulse rates by half decreased their effective doses to one-third and two-fifths of the baseline dose, respectively. No significant difference in their doses was detected after the placement of the shielding screens. Therefore, the action research effectively decreased the occupational doses of the vascular IR nurses.

  17. Radiation-induced change of optical property of hydroxypropyl cellulose hydrogel containing methacrylate compounds: As a basis for development of a new type of radiation dosimeter

    NASA Astrophysics Data System (ADS)

    Yamashita, Shinichi; Hiroki, Akihiro; Taguchi, Mitsumasa

    2014-08-01

    Hydrogels with matrix of a cellulose derivative, hydrogel of hydroxpropyl cellulose (HPC), containing two of methacrylate compounds (2-hydroxyethyl methacrylate (HEMA) and poly(ethylene glycol) dimethacrylate (9G)) were irradiated with 60Co γ-rays. The gels become white with irradiation, and thus, could be candidates of a new type of radiation dosimeter utilized in radiation therapy because the gels become white with irradiation and can be confirmed directly by human eyes even at low doses of 1-2 Gy. Radiation-induced change of optical properties, haze value and UV-vis absorption spectrum, of the irradiated gels was measured. Dose response of the white turbidity appearance was different for different compositions of the methacrylate compounds as well as for different dose rates. The degree of the radiation-induced white turbidity was quantified by measuring haze value, showing linear dose response in low dose region (<2 Gy). We also analyzed the gels with a UV-vis spectrometer and HEMA- and 9G-rich gels gave different spectral shapes, indicating that there are at least two mechanisms leading to the white turbidity. In addition, dose rate dependence was smaller for 9G-rich gels than HEMA-rich gels in the range of 0.015-1.5 Gy/min.

  18. Intravenous Nicotine Self-Administration in Smokers: Dose-Response Function and Sex Differences.

    PubMed

    Jensen, Kevin P; DeVito, Elise E; Valentine, Gerald; Gueorguieva, Ralitza; Sofuoglu, Mehmet

    2016-07-01

    Sex differences in the sensitivity to nicotine may influence vulnerability to tobacco dependence. The goal of this study was to investigate the dose-response function for the reinforcing and subjective effects of intravenous nicotine in male and female smokers. Tobacco-dependent subjects (12 male and 14 female) participated in four experimental sessions in which they received sample infusions of saline and nicotine (0.1, 0.2, 0.3, or 0.4 mg doses) in a randomized double-blind crossover design. During each session, subjects first received the sample infusions, and heart rate (HR), blood pressure, and subjective stimulatory, pleasurable and aversive responses were monitored. Immediately following the sample infusions, subjects self-administered either nicotine or saline in six double-blind forced-choice trials. A sex by dose interaction was observed in the nicotine choice paradigm. Nicotine self-administration rate was negatively correlated with nicotine dose in males (males displayed choice preference for low doses of nicotine over high doses of nicotine), but no significant relationship between dose and choice preference was evident in females. Relative to placebo, sample doses of nicotine increased heart rate and blood pressure, and induced stimulatory, pleasurable, and aversive subjective effects. Diastolic blood pressure increased dose dependently in males, but not in females. These findings, which demonstrate sex differences in nicotine self-administration for doses that are near to the reinforcement threshold, suggest that male and female smokers may respond differently to the changes in nicotine doses available for self-administration.

  19. Polymer gel dosimeters for pretreatment radiotherapy verification using the three-dimensional gamma evaluation and pass rate maps.

    PubMed

    Hsieh, Ling-Ling; Shieh, Jiunn-I; Wei, Li-Ju; Wang, Yi-Chun; Cheng, Kai-Yuan; Shih, Cheng-Ting

    2017-05-01

    Polymer gel dosimeters (PGDs) have been widely studied for use in the pretreatment verification of clinical radiation therapy. However, the readability of PGDs in three-dimensional (3D) dosimetry remain unclear. In this study, the pretreatment verifications of clinical radiation therapy were performed using an N-isopropyl-acrylamide (NIPAM) PGD, and the results were used to evaluate the performance of the NIPAM PGD on 3D dose measurement. A gel phantom was used to measure the dose distribution of a clinical case of intensity-modulated radiation therapy. Magnetic resonance imaging scans were performed for dose readouts. The measured dose volumes were compared with the planned dose volume. The relative volume histograms showed that relative volumes with a negative percent dose difference decreased as time elapsed. Furthermore, the histograms revealed few changes after 24h postirradiation. For the 3%/3mm and 2%/2mm criteria, the pass rates of the 12- and 24-h dose volumes were higher than 95%, respectively. This study thus concludes that the pass rate map can be used to evaluate the dose-temporal readability of PGDs and that the NIPAM PGD can be used for clinical pretreatment verifications. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Effects of UVB radiation on grazing of two cladocerans from high-altitude Andean lakes

    PubMed Central

    Rejas, Danny

    2017-01-01

    Climate change and water extraction may result in increased exposition of the biota to ultraviolet-B radiation (UVB) in high-altitude Andean lakes. Although exposition to lethal doses in these lakes is unlikely, sub-lethal UVB doses may have strong impacts in key compartments such as zooplankton. Here, we aimed at determining the effect of sub-lethal UVB doses on filtration rates of two cladoceran species (Daphnia pulicaria and Ceriodaphnia dubia). We firstly estimated the Incipient Limiting Concentration (ILC) and the Gut Passage Time (GPT) for both species. Thereafter we exposed clones of each species to four increasing UVB doses (treatments): i) DUV-0 (Control), ii) DUV-1 (0.02 MJ m2), iii) DUV-2 (0.03 MJ m2) and iv) DUV-3 (0.15 MJ m2); and estimated their filtration rates using fluorescent micro-spheres. Our results suggest that increasing sub-lethal doses of UVB radiation may strongly disturb the structure and functioning of high-altitude Andean lakes. Filtration rates of D. pulicaria were not affected by the lowest dose applied (DUV-1), but decreased by 50% in treatments DUV-2 and DUV-3. Filtration rates for C. dubia were reduced by more than 80% in treatments DUV-1 and DUV-2 and 100% of mortality occurred at the highest UVB dose applied (DUV-3). PMID:28379975

  1. Impact of a phenytoin loading dose program in the emergency department.

    PubMed

    Brancaccio, Adam; Giuliano, Christopher; McNorton, Kelly; Delgado, George

    2014-11-01

    The use of a combined physician-and pharmacist-directed phenytoin loading dose program in an emergency department (ED) was evaluated. This single-center, observational, preimplementation-postimplementation study evaluated adult patients who received a phenytoin loading dose in the ED. The primary outcome compared the proportion of optimal phenytoin loading doses in the preimplementation and postimplementation groups. The postimplementation group was further stratified into pharmacist- and prescriber-dosing groups. Other outcomes evaluated included the numbers of appropriate serum phenytoin concentrations measured, adverse drug reactions (ADRs), and recurrence of seizures within 24 hours of loading dose administration in the preimplementation and postimplementation groups. There was no difference in the proportion of optimal phenytoin loading doses between the preimplementation and postimplementation groups (50% versus 62%, respectively; p=0.19). When stratified by individual groups, the rate of optimal phenytoin loading doses increased by 64% in the postimplementation pharmacist group (50% versus 82%, p=0.007), while the rate in the prescriber-dosing group remained relatively unchanged (50% versus 49%, p=0.91). The number of appropriate serum phenytoin concentrations significantly improved in the postimplementation versus preimplementation group (65% versus 40%, p=0.025). Rates of ADRs and recurrence of seizures did not differ across the study groups. No change in the percentage of optimal phenytoin loading doses in the ED was observed after implementation of a combined pharmacist- and physician- dosing program. When stratified into pharmacist or prescriber dosing, the pharmacist-led dosing program significantly improved the proportion of patients who received optimal phenytoin loading doses. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  2. Psilocybin occasioned mystical-type experiences: Immediate and persisting dose-related effects

    PubMed Central

    Griffiths, R. R.; Johnson, M.W.; Richards, W. A.; Richards, B.D.; McCann, U.; Jesse, R.

    2012-01-01

    Rationale This dose-effect study extends previous observations showing that psilocybin can occasion mystical-type experiences having persisting positive effects on attitudes, mood, and behavior. Objectives This double-blind study evaluated psilocybin (0, 5, 10, 20, 30 mg/70 kg, p.o.) administered under supportive conditions. Methods Participants were 18 adults (17 hallucinogen-naïve). Five 8-hour sessions were conducted individually for each participant at 1-month intervals. Participants were randomized to receive the four active doses in either ascending or descending order (9 participants each). Placebo was scheduled quasi-randomly. During sessions volunteers used eyeshades and were instructed to direct their attention inward. Volunteers completed questionnaires assessing effects immediately after and 1 month after each session, and at 14 months follow-up. Results Psilocybin produced acute perceptual and subjective effects including, at 20 and/or 30 mg/70 kg, extreme anxiety/fear (39% of volunteers) and/or mystical-type experience (72% of volunteers). One month after sessions at the two highest doses, volunteers rated the psilocybin experience as having substantial personal and spiritual significance, and attributed to the experience sustained positive changes in attitudes, mood, and behavior, with the ascending dose sequence showing greater positive effects. At 14 months, ratings were undiminished and were consistent with changes rated by community observers. Both the acute and persisting effects of psilocybin were generally a monotonically increasing function of dose, with the lowest dose showing significant effects. Conclusions Under supportive conditions, 20 and 30 mg/70 kg psilocybin occasioned mystical-type experiences having persisting positive effects on attitudes, mood and behavior. Implications for therapeutic trials are discussed. PMID:21674151

  3. Poster — Thur Eve — 38: Feasibility of a Table-Top Total Body Irradiation Technique using Robotic Couch Motion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chin, Erika; Otto, Karl; Hoppe, Richard

    Purpose: To develop and test the feasibility of a table-top implementation for total body irradiation (TBI) via robotic couch motion and coordinated monitor unit modulation on a standard C-arm linac geometry. Methods: To allow for collision free delivery and to maximize the effective field size, the couch was rotated to 270° IEC and dropped to 150 cm from the vertical radiation source. The robotic delivery was programmed using the TrueBeam STx Developer Mode using custom XML scripting. To assess the dosimetry of a sliding 30×20 cm{sup 2} field, irradiation on a solid water phantom of varying thickness was analyzed usingmore » EDR2 radiographic film and OSLDs. Beam modulation was achieved by dividing the couch path into multiple segments of varying dose rates and couch speeds in order to deliver 120 cGy to the midline. Results: The programmed irradiation in conjunction with coordinated couch motion was successfully delivered on a TrueBeam linac. When no beam modulation was employed, the dose difference between two different phantom sections was 17.0%. With simple beam modulation via changing dose rates and couch speeds, the desired prescription dose can be achieved at the centre of each phantom section within 1.9%. However, dose deviation at the junction was 9.2% due to the nonphysical change in the phantom thickness. Conclusions: The feasibility of robotic table-top TBI on a C-arm linac geometry was experimentally demonstrated. To achieve a more uniform dose distribution, inverse-planning allowing for a combination of dose rate modulation, jaw tracking and MLC motion is under investigation.« less

  4. Influence of γ-irradiation and temperature on the mechanical properties of EPDM cable insulation

    NASA Astrophysics Data System (ADS)

    Šarac, T.; Quiévy, N.; Gusarov, A.; Konstantinović, M. J.

    2016-08-01

    The mechanical properties of EPDM polymers, degraded as a result of extensive thermal and radiochemical aging treatment, are studied. The focus is given to dose rate effects in polymer insulation materials extracted from industrial cables in use in Belgian nuclear power plants. All studied mechanical characteristics such as the ultimate tensile stress, the Young's modulus, and the total elongation (or elongation at break) are found to be strongly affected by the irradiation dose. The ultimate tensile stress and Young's modulus are clearly exhibiting the dose rate effect, which originated from oxidation mediated interplay of polymer cross-linking and chain scission processes. The change of crossover between these two processes is found to be gradual, without critical dose rate or temperature values. On the contrary, the total elongation is observed not to be sensitive neither to irradiation temperature nor to the dose rate. Both cross-linking and chain scission seem to affect the total elongation in a similar way by reducing the average polymers chain length. This idea is confirmed by the model which shows that all total elongation data as a function of irradiation time can be reproduced by varying a single parameter, the pre-exponential factor of the irradiation rate constant.

  5. SU-F-J-64: Comparison of Dosimetric Robustness Between Proton Therapy and IMRT Plans Following Tumor Regression for Locally Advanced Non-Small Cell Lung Cancer (NSCLC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teng, C; Ainsley, C; Teo, B

    Purpose: In the light of tumor regression and normal tissue changes, dose distributions can deviate undesirably from what was planned. As a consequence, replanning is sometimes necessary during treatment to ensure continued tumor coverage or to avoid overdosing organs at risk (OARs). Proton plans are generally thought to be less robust than photon plans because of the proton beam’s higher sensitivity to changes in tissue composition, suggesting also a higher likely replanning rate due to tumor regression. The purpose of this study is to compare dosimetric deviations between forward-calculated double scattering (DS) proton plans with IMRT plans upon tumor regression,more » and assesses their impact on clinical replanning decisions. Methods: Ten consecutive locally advanced NSCLC patients whose tumors shrank > 50% in volume and who received four or more CT scans during radiotherapy were analyzed. All the patients received proton radiotherapy (6660 cGy, 180 cGy/fx). Dosimetric robustness during therapy was characterized by changes in the planning objective metrics as well as by point-by-point root-mean-squared differences for the entire PTV, ITV, and OARs (heart, cord, esophagus, brachial plexus and lungs) DVHs. Results: Sixty-four pairs of DVHs were reviewed by three clinicians, who requested a replanning rate of 16.7% and 18.6% for DS and IMRT plans, respectively, with a high agreement between providers. Robustness of clinical indicators was found to depend on the beam orientation and dose level on the DVH curve. Proton dose increased most in OARs distal to the PTV along the beam path, but these changes were primarily in the mid to low dose levels. In contrast, the variation in IMRT plans occurred primarily in the high dose region. Conclusion: Robustness of clinical indicators depends where on the DVH curves comparisons are made. Similar replanning rates were observed for DS and IMRT plans upon large tumor regression.« less

  6. The Effects of Gamma and Proton Radiation Exposure on Hematopoietic Cell Counts in the Ferret Model

    PubMed Central

    Sanzari, Jenine K.; Wan, X. Steven; Krigsfeld, Gabriel S.; Wroe, Andrew J.; Gridley, Daila S.; Kennedy, Ann R.

    2014-01-01

    Exposure to total-body radiation induces hematological changes, which can detriment one's immune response to wounds and infection. Here, the decreases in blood cell counts after acute radiation doses of γ-ray or proton radiation exposure, at the doses and dose-rates expected during a solar particle event (SPE), are reported in the ferret model system. Following the exposure to γ-ray or proton radiation, the ferret peripheral total white blood cell (WBC) and lymphocyte counts decreased whereas neutrophil count increased within 3 hours. At 48 hours after irradiation, the WBC, neutrophil, and lymphocyte counts decreased in a dose-dependent manner but were not significantly affected by the radiation type (γ-rays verses protons) or dose rate (0.5 Gy/minute verses 0.5 Gy/hour). The loss of these blood cells could accompany and contribute to the physiological symptoms of the acute radiation syndrome (ARS). PMID:25356435

  7. Uncoupling of the baroreflex by N(N)-cholinergic blockade in dissecting the components of cardiovascular regulation

    NASA Technical Reports Server (NTRS)

    Shannon, J. R.; Jordan, J.; Black, B. K.; Costa, F.; Robertson, D.

    1998-01-01

    Systemic administration of adrenergic agonists and nitric oxide donors is used extensively to determine cardiovascular receptor sensitivity. Conclusions regarding receptor sensitivity in the presence of the baroreflex may be misleading. In 8 normal volunteers, we determined the heart rate and blood pressure changes after incremental bolus doses of isoproterenol, phenylephrine, and sodium nitroprusside before and during neuronal nicotinic cholinergic (N(N)-cholinergic) blockade with trimethaphan. Results are given as median (25th/75th percentile). With trimethaphan, the baroreflex slope (as determined by bolus doses of nitroprusside and phenylephrine) decreased from 24 (22/26) to 0.00 (0.00/0.09) ms/mm Hg (P<0.01). The dose of isoproterenol that decreased systolic blood pressure (SBP) 12.5 mm Hg changed from 0.61 (0.51/5.3) to 0.17 (0.12/0.21) microg (P<0.01); the dose required to increase heart rate 12.5 bpm changed from 0.22 (0.17/0.41) to 0.74 (0.33/2.3) microg (P<0.01). The dose of nitroprusside required to decrease SBP 12.5 mm Hg changed from 2.3 (1.3/3.4) to 0.18 (0.14/0.24) microg/kg (P<0.01). The dose of phenylephrine required to increase SBP 12.5 mm Hg changed from 135 (110/200) to 16 (10/30) microg (P<0.01). We conclude that the efferent arc of the baroreflex can be completely interrupted with N(N)-cholinergic blockade. Estimation of adrenoreceptor sensitivity and sensitivity to nitric oxide donors by systemic administration of agonists is severely confounded by baroreflexes. Uncoupling of the baroreflex by N(N)-cholinergic blockade may be a useful method to obtain an integrated measure of adrenergic receptor sensitivity and sensitivity to nitric oxide donors in humans. This approach would permit the comparison of normal and abnormal physiological states without the "noise" of baroreflex buffering.

  8. Computation of restoration of ligand response in the random kinetics of a prostate cancer cell signaling pathway.

    PubMed

    Dana, Saswati; Nakakuki, Takashi; Hatakeyama, Mariko; Kimura, Shuhei; Raha, Soumyendu

    2011-01-01

    Mutation and/or dysfunction of signaling proteins in the mitogen activated protein kinase (MAPK) signal transduction pathway are frequently observed in various kinds of human cancer. Consistent with this fact, in the present study, we experimentally observe that the epidermal growth factor (EGF) induced activation profile of MAP kinase signaling is not straightforward dose-dependent in the PC3 prostate cancer cells. To find out what parameters and reactions in the pathway are involved in this departure from the normal dose-dependency, a model-based pathway analysis is performed. The pathway is mathematically modeled with 28 rate equations yielding those many ordinary differential equations (ODE) with kinetic rate constants that have been reported to take random values in the existing literature. This has led to us treating the ODE model of the pathways kinetics as a random differential equations (RDE) system in which the parameters are random variables. We show that our RDE model captures the uncertainty in the kinetic rate constants as seen in the behavior of the experimental data and more importantly, upon simulation, exhibits the abnormal EGF dose-dependency of the activation profile of MAP kinase signaling in PC3 prostate cancer cells. The most likely set of values of the kinetic rate constants obtained from fitting the RDE model into the experimental data is then used in a direct transcription based dynamic optimization method for computing the changes needed in these kinetic rate constant values for the restoration of the normal EGF dose response. The last computation identifies the parameters, i.e., the kinetic rate constants in the RDE model, that are the most sensitive to the change in the EGF dose response behavior in the PC3 prostate cancer cells. The reactions in which these most sensitive parameters participate emerge as candidate drug targets on the signaling pathway. 2011 Elsevier Ireland Ltd. All rights reserved.

  9. Validation of an improved helical diode array and dose reconstruction software using TG-244 datasets and stringent dose comparison criteria.

    PubMed

    Ahmed, Saeed; Nelms, Benjamin; Kozelka, Jakub; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir

    2016-11-08

    The original helical ArcCHECK (AC) diode array and associated software for 3D measurement-guided dose reconstruction were characterized and validated; however, recent design changes to the AC required that the subject be revisited. The most important AC change starting in 2014 was a significant reduction in the overresponse of diodes to scattered radiation outside of the direct beam, accom-plished by reducing the amount of high-Z materials adjacent to the diodes. This change improved the diode measurement accuracy, but in the process invalidated the dose reconstruction models that were assembled based on measured data acquired with the older version of the AC. A correction mechanism was intro-duced in the reconstruction software (3DVH) to accommodate this and potential future design changes without requiring updating model parameters. For each permutation of AC serial number and beam model, the user can define in 3DVH a single correction factor which will be used to compensate for the difference in the out-of-field response between the new and original AC designs. The exact value can be determined by minimizing the dose-difference with an ionization chamber or another independent dosimeter. A single value of 1.17, corresponding to the maximum measured out-of-field response difference between the new and old AC, provided satisfactory results for all studied energies (6X, 15X, and flatten-ing filter-free 10XFFF). A library of standard cases recommended by the AAPM TG-244 Report was used for reconstructed dose verification. The overall difference between reconstructed dose and an ion chamber in a water-equivalent phantom in the targets was 0.0% ± 1.4% (1 SD). The reconstructed dose on a homogeneous phantom was also compared to a biplanar diode dosimeter (Delta4) using gamma analysis with 2% (local dose-error normalization) / 2 mm / 10% cutoff criteria. The mean agreement rate was 96.7% ± 3.7%. For the plans common with the previous comparison, the mean agreement rate was 98.3% ± 0.8%, essentially unchanged. We conclude that the proposed software modification adequately addresses the change in the dosimeter response. © 2016 The Authors.

  10. The Effects of Low Dose-Rate Ionizing Radiation on the Shapes of Transients in the LM124 Operational Amplifier

    NASA Technical Reports Server (NTRS)

    Buchner, Stephen; McMorrow, Dale; Roche, Nicholas; Dusseau, Laurent; Pease, Ron L.

    2008-01-01

    Shapes of single event transients (SETs) in a linear bipolar circuit (LM124) change with exposure to total ionizing dose (TID) radiation. SETs shape changes are a direct consequence of TID-induced degradation of bipolar transistor gain. A reduction in transistor gain causes a reduction in the drive current of the current sources in the circuit, and it is the lower drive current that most affects the shapes of large amplitude SETs.

  11. The methodology study of time accelerated irradiation of elastomers

    NASA Astrophysics Data System (ADS)

    Ito, Masayuki

    2005-07-01

    The article studied the methods how to shorten the irradiation time by increasing dose rate without changing the relationship between dose versus properties of degraded samples. The samples used were nine kinds of EPDM which have different compounding formula. The different dose of Co-γ ray was exposed to the samples. The maximum dose was 2 MGy. The reference condition to be compared with two short time test conditions is irradiation of 0.33 kGy/h at room temperature. Two methods shown below were studied as the time-accelerate irradiation conditions.

  12. Psilocybin produces substantial and sustained decreases in depression and anxiety in patients with life-threatening cancer: A randomized double-blind trial

    PubMed Central

    Griffiths, Roland R; Johnson, Matthew W; Carducci, Michael A; Umbricht, Annie; Richards, William A; Richards, Brian D; Cosimano, Mary P; Klinedinst, Margaret A

    2016-01-01

    Cancer patients often develop chronic, clinically significant symptoms of depression and anxiety. Previous studies suggest that psilocybin may decrease depression and anxiety in cancer patients. The effects of psilocybin were studied in 51 cancer patients with life-threatening diagnoses and symptoms of depression and/or anxiety. This randomized, double-blind, cross-over trial investigated the effects of a very low (placebo-like) dose (1 or 3 mg/70 kg) vs. a high dose (22 or 30 mg/70 kg) of psilocybin administered in counterbalanced sequence with 5 weeks between sessions and a 6-month follow-up. Instructions to participants and staff minimized expectancy effects. Participants, staff, and community observers rated participant moods, attitudes, and behaviors throughout the study. High-dose psilocybin produced large decreases in clinician- and self-rated measures of depressed mood and anxiety, along with increases in quality of life, life meaning, and optimism, and decreases in death anxiety. At 6-month follow-up, these changes were sustained, with about 80% of participants continuing to show clinically significant decreases in depressed mood and anxiety. Participants attributed improvements in attitudes about life/self, mood, relationships, and spirituality to the high-dose experience, with >80% endorsing moderately or greater increased well-being/life satisfaction. Community observer ratings showed corresponding changes. Mystical-type psilocybin experience on session day mediated the effect of psilocybin dose on therapeutic outcomes. Trial Registration ClinicalTrials.gov identifier: NCT00465595 PMID:27909165

  13. Psilocybin produces substantial and sustained decreases in depression and anxiety in patients with life-threatening cancer: A randomized double-blind trial.

    PubMed

    Griffiths, Roland R; Johnson, Matthew W; Carducci, Michael A; Umbricht, Annie; Richards, William A; Richards, Brian D; Cosimano, Mary P; Klinedinst, Margaret A

    2016-12-01

    Cancer patients often develop chronic, clinically significant symptoms of depression and anxiety. Previous studies suggest that psilocybin may decrease depression and anxiety in cancer patients. The effects of psilocybin were studied in 51 cancer patients with life-threatening diagnoses and symptoms of depression and/or anxiety. This randomized, double-blind, cross-over trial investigated the effects of a very low (placebo-like) dose (1 or 3 mg/70 kg) vs. a high dose (22 or 30 mg/70 kg) of psilocybin administered in counterbalanced sequence with 5 weeks between sessions and a 6-month follow-up. Instructions to participants and staff minimized expectancy effects. Participants, staff, and community observers rated participant moods, attitudes, and behaviors throughout the study. High-dose psilocybin produced large decreases in clinician- and self-rated measures of depressed mood and anxiety, along with increases in quality of life, life meaning, and optimism, and decreases in death anxiety. At 6-month follow-up, these changes were sustained, with about 80% of participants continuing to show clinically significant decreases in depressed mood and anxiety. Participants attributed improvements in attitudes about life/self, mood, relationships, and spirituality to the high-dose experience, with >80% endorsing moderately or greater increased well-being/life satisfaction. Community observer ratings showed corresponding changes. Mystical-type psilocybin experience on session day mediated the effect of psilocybin dose on therapeutic outcomes. ClinicalTrials.gov identifier: NCT00465595. © The Author(s) 2016.

  14. Influence of dose rate on the induction of simple and complex chromosome exchanges by gamma rays.

    PubMed

    Loucas, Bradford D; Eberle, Richard; Bailey, Susan M; Cornforth, Michael N

    2004-10-01

    Single-color painting of whole chromosomes, or protocols in which only a few chromosomes are distinctively painted, will always fail to detect a proportion of complex exchanges because they frequently produce pseudosimple painting patterns that are indistinguishable from those produced by bona fide simple exchanges. When 24-color multi-fluor FISH (mFISH) was employed for the purpose of distinguishing (truly) simple from pseudosimple exchanges, it was confirmed that the acute low-LET radiation dose-response relationship for simple exchanges lacked significant upward curvature. This result has been interpreted to indicate that the formation of simple exchanges requires only one chromosome locus be damaged (e.g. broken) by radiation to initiate an exchange-not two, as classical cytogenetic theory maintains. Because a one-lesion mechanism implies single-track action, it follows that the production of simple exchanges should not be influenced by changes in dose rate. To examine this prediction, we irradiated noncycling primary human fibroblasts with graded doses of (137)Cs gamma rays at an acute dose rate of 1.10 Gy/min and compared, using mFISH, the yield of simple exchanges to that observed after exposure to the same radiation delivered at a chronic dose rate of 0.08 cGy/min. The shape of the dose response was found to be quasi-linear for both dose rates, but, counter to providing support for a one-lesion mechanism, the yield of simple aberrations was greatly reduced by protracted exposure. Although chronic doses were delivered at rates low enough to produce damage exclusively by single-track action, this did not altogether eliminate the formation of complex aberrations, an analysis of which leads to the conclusion that a single track of low-LET radiation is capable of inducing complex exchanges requiring up to four proximate breaks for their formation. For acute exposures, the ratio of simple reciprocal translocations to simple dicentrics was near unity.

  15. Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karunamuni, Roshan; Bartsch, Hauke; White, Nathan S.

    Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thicknessmore » between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.« less

  16. Quantitative Analysis of Electron Beam Damage in Organic Thin Films

    PubMed Central

    2017-01-01

    In transmission electron microscopy (TEM) the interaction of an electron beam with polymers such as P3HT:PCBM photovoltaic nanocomposites results in electron beam damage, which is the most important factor limiting acquisition of structural or chemical data at high spatial resolution. Beam effects can vary depending on parameters such as electron dose rate, temperature during imaging, and the presence of water and oxygen in the sample. Furthermore, beam damage will occur at different length scales. To assess beam damage at the angstrom scale, we followed the intensity of P3HT and PCBM diffraction rings as a function of accumulated electron dose by acquiring dose series and varying the electron dose rate, sample preparation, and the temperature during acquisition. From this, we calculated a critical dose for diffraction experiments. In imaging mode, thin film deformation was assessed using the normalized cross-correlation coefficient, while mass loss was determined via changes in average intensity and standard deviation, also varying electron dose rate, sample preparation, and temperature during acquisition. The understanding of beam damage and the determination of critical electron doses provides a framework for future experiments to maximize the information content during the acquisition of images and diffraction patterns with (cryogenic) transmission electron microscopy. PMID:28553431

  17. Revised radiobiological modelling of the contribution of synchronous chemotherapy to the rate of grades 3-4 mucositis in head and neck cancer.

    PubMed

    Meade, Sara; McConkey, Chris; Sanghera, Paul; Mehanna, Hisham; Hartley, Andrew

    2013-12-01

    Biological effective dose (BED) calculations modelled on reduced accelerated repopulation when synchronous chemotherapy is delivered significantly correlate with observed differences in local control in randomised trials of platinum-based chemoradiation. The purpose of this study was to examine whether a similar relationship existed in the context of grades 3-4 mucositis. Biological effective dose from radiotherapy and synchronous chemotherapy was calculated using three different models: AB using the additional BED attributable to chemotherapy and standard repopulation parameters; zero repopulation (ZRP) using zero correction for repopulation; and variable t(p) (Vt(p)) using a variable doubling time for mucosal stem cell repopulation. The correlation between the percentage change in biological effective dose between trial arms, and the observed percentage change in the rate of grades 3-4 mucositis was examined by using the Pearson product-moment correlation. With the AB model, there were no significant correlations with observed differences in rates of grades 3-4 mucositis. With either the ZRP or Vt(p) models, significant correlations were observed. A value of 5 days for the doubling time during repopulation (T(p)) was associated with the most significant correlation (P = 0.002). Models where the dose lost due to accelerated repopulation is reduced imply a therapeutic loss from the use of synchronous chemotherapy when only local control and the rate of acute grades 3-4 mucositis are considered. © 2013 The Royal Australian and New Zealand College of Radiologists.

  18. Medical management of ectopic pregnancy with single-dose and 2-dose methotrexate protocols: human chorionic gonadotropin trends and patient outcomes.

    PubMed

    Mergenthal, Michelle C; Senapati, Suneeta; Zee, Jarcy; Allen-Taylor, Lynne; Whittaker, Paul G; Takacs, Peter; Sammel, Mary D; Barnhart, Kurt T

    2016-11-01

    Ectopic pregnancy, although rare, is an important cause of female morbidity and mortality and early, effective treatment is critical. Systemic methotrexate has become widely accepted as a safe and effective alternative to surgery in the stable patient. As the number and timing of methotrexate doses differ in the 3 main medical treatment regimens, one might expect trends in serum human chorionic gonadotropin and time to resolution to vary depending on protocol. Furthermore, human chorionic gonadotropin trends and time to resolution may predict ultimate treatment success. This study hypothesized that the 2-dose methotrexate protocol would be associated with a faster initial decline in serum human chorionic gonadotropin levels and a shorter time to resolution compared to the single-dose protocol. A prospective multicenter cohort study included clinical data from women who received medical management for ectopic pregnancy. Rates of human chorionic gonadotropin change and successful pregnancy resolution were assessed. Propensity score modeling addressed confounding by indication, the potential for differential assignment of patients with better prognosis to the single-dose methotrexate protocol. In all, 162 ectopic pregnancies were in the final analysis; 114 (70%) were treated with the single-dose methotrexate and 48 (30%) with the 2-dose protocol. Site, race, ethnicity, and reported pain level were associated with differential protocol allocation (P < .001, P = .011, P < .001, and P = .035, respectively). Women had similar initial human chorionic gonadotropin levels in either protocol but the mean rate of decline of human chorionic gonadotropin from day 0 (day of administration of first dose of methotrexate) to day 7 was significantly more rapid in women who received the single-dose protocol compared to those treated with the 2-dose protocol (mean change -31.3% vs -10.4%, P = .037, adjusted for propensity score and site). The 2 protocols had no significant differences in success rate or time to resolution. In a racially and geographically diverse group of women, the single- and double-dose methotrexate protocols had comparable outcomes. The more rapid human chorionic gonadotropin initial decline in the single-dose group suggested these patients were probably at lower risk for ectopic rupture than those getting the 2-dose protocol. A prospective randomized controlled design is needed to remove confounding by indication. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Factors Influencing the Cardiovascular Response to Subanesthetic Ketamine: A Randomized, Placebo-Controlled Trial

    PubMed Central

    Li, Shijia; Lord, Anton; Colic, Lejla; Krause, Anna Linda; Batra, Anil; Kretzschmar, Moritz A; Sweeney-Reed, Catherine M; Behnisch, Gusalija; Schott, Björn H; Walter, Martin

    2017-01-01

    Abstract Background The increasing use of ketamine as a potential rapid-onset antidepressant necessitates a better understanding of its effects on blood pressure and heart rate, well-known side effects at higher doses. For the subanesthetic dose used for depression, potential predictors of these cardiovascular effects are important factors influencing clinical decisions. Since ketamine influences the sympathetic nervous system, we investigated the impact of autonomic nervous system-related factors on the cardiovascular response: a genetic polymorphism in the norepinephrine transporter and gender effects. Methods Blood pressure and heart rate were monitored during and following administration of a subanesthetic dose of ketamine or placebo in 68 healthy participants (mean age 26.04 ±5.562 years) in a double-blind, randomized, controlled, parallel-design trial. The influences of baseline blood pressure/heart rate, gender, and of a polymorphism in the norepinephrine transporter gene (NET SLC6A2, rs28386840 [A-3081T]) on blood pressure and heart rate changes were investigated. To quantify changes in blood pressure and heart rate, we calculated the maximum change from baseline (ΔMAX) and the time until maximum change (TΔMAX). Results Systolic and diastolic blood pressure as well as heart rate increased significantly upon ketamine administration, but without reaching hypertensive levels. During administration, the systolic blood pressure at baseline (TP0Sys) correlated negatively with the time to achieve maximal systolic blood pressure (TΔMAXSys, P<.001). Furthermore, women showed higher maximal diastolic blood pressure change (ΔMAXDia, P<.001) and reached this peak earlier than men (TΔMAXDia, P=.017) at administration. NET rs28386840 [T] carriers reached their maximal systolic blood pressure during ketamine administration significantly earlier than [A] homozygous (TΔMAXSys, P=.030). In a combined regression model, both genetic polymorphism and TP0Sys were significant predictors of TΔMAXSys (P<.0005). Conclusions Subanesthetic ketamine increased both blood pressure and heart rate without causing hypertensive events. Furthermore, we identified gender and NET rs28386840 genotype as factors that predict increased cardiovascular sequelae of ketamine administration in our young, healthy study population providing a potential basis for establishing monitoring guidelines. PMID:29099972

  20. High dose-per-pulse electron beam dosimetry: Usability and dose-rate independence of EBT3 Gafchromic films.

    PubMed

    Jaccard, Maud; Petersson, Kristoffer; Buchillier, Thierry; Germond, Jean-François; Durán, Maria Teresa; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François O; Bailat, Claude

    2017-02-01

    The aim of this study was to assess the suitability of Gafchromic EBT3 films for reference dose measurements in the beam of a prototype high dose-per-pulse linear accelerator (linac), capable of delivering electron beams with a mean dose-rate (Ḋ m ) ranging from 0.07 to 3000 Gy/s and a dose-rate in pulse (Ḋ p ) of up to 8 × 10 6 Gy/s. To do this, we evaluated the overall uncertainties in EBT3 film dosimetry as well as the energy and dose-rate dependence of their response. Our dosimetric system was composed of EBT3 Gafchromic films in combination with a flatbed scanner and was calibrated against an ionization chamber traceable to primary standard. All sources of uncertainties in EBT3 dosimetry were carefully analyzed using irradiations at a clinical radiotherapy linac. Energy dependence was investigated with the same machine by acquiring and comparing calibration curves for three different beam energies (4, 8 and 12 MeV), for doses between 0.25 and 30 Gy. Ḋ m dependence was studied at the clinical linac by changing the pulse repetition frequency (f) of the beam in order to vary Ḋ m between 0.55 and 4.40 Gy/min, while Ḋ p dependence was probed at the prototype machine for Ḋ p ranging from 7 × 10 3 to 8 × 10 6 Gy/s. Ḋ p dependence was first determined by studying the correlation between the dose measured by films and the charge of electrons measured at the exit of the machine by an induction torus. Furthermore, we compared doses from the films to independently calibrated thermo-luminescent dosimeters (TLD) that have been reported as being dose-rate independent up to such high dose-rates. We report that uncertainty below 4% (k = 2) can be achieved in the dose range between 3 and 17 Gy. Results also demonstrated that EBT3 films did not display any detectable energy dependence for electron beam energies between 4 and 12 MeV. No Ḋ m dependence was found either. In addition, we obtained excellent consistency between films and TLDs over the entire Ḋ p range attainable at the prototype linac confirming the absence of any dose-rate dependence within the investigated range (7 × 10 3 to 8 × 10 6 Gy/s). This aspect was further corroborated by the linear relationship between the dose-per-pulse (D p ) measured by films and the charge per pulse (C p ) measured at the prototype linac exit. Our study shows that the use of EBT3 Gafchromic films can be extended to reference dosimetry in pulsed electron beams with a very high dose rate. The measurement results are associated with an overall uncertainty below 4% (k = 2) and are dose-rate and energy independent. © 2016 American Association of Physicists in Medicine.

  1. The role of training dose in drug discrimination: a review

    PubMed Central

    Stolerman, Ian P; Childs, Emma; Ford, Matthew M; Grant, Kathleen A

    2011-01-01

    Drug discrimination has been an important technique in behavioural pharmacology for at least 40 years. The characteristics of drug-produced discriminative stimuli are influenced by behavioural and pharmacological variables, including the doses used to establish discriminations. This review covers studies on the effects of varying the training dose of a drug in a search for general principles that are applicable across different drug classes and methodological approaches. With respect to quantitative changes, relationships between training dose and rate of acquisition or magnitude of stimulus control were found for most drug classes. Acquisition accelerated with dose up to a point beyond which drug-induced impairments of performance had a deleterious impact. Sensitivity to the training drug as measured by ED50 values typically increased when the training dose was reduced. Qualitative changes were more complex and appeared to fall into three categories: (i) changes in profiles of generalisation between partial and full agonists; (ii) reduced specificity of some discriminations at small training doses and (iii) changes in the relative salience of actions mediated through different neurotransmitter systems or from central and peripheral sites. Three-lever discrimination procedures incorporating ‘drug versus drug’ or “dose versus dose” contingencies enabled detection of more subtle differences than the simple ‘drug versus no drug’ approach when applied to the opioid, hallucinogen and barbiturate classes of drugs. These conclusions have implications for the interpretation of data from studies that utilise either within- or between-subject designs for studying the discriminative stimulus effects of drugs. PMID:21808191

  2. Evaluation of the effect of prostate volume change on tumor control probability in LDR brachytherapy.

    PubMed

    Knaup, Courtney; Mavroidis, Panayiotis; Stathakis, Sotirios; Smith, Mark; Swanson, Gregory; Papanikolaou, Niko

    2011-09-01

    This study evaluates low dose-rate brachytherapy (LDR) prostate plans to determine the biological effect of dose degradation due to prostate volume changes. In this study, 39 patients were evaluated. Pre-implant prostate volume was determined using ultrasound. These images were used with the treatment planning system (Nucletron Spot Pro 3.1(®)) to create treatment plans using (103)Pd seeds. Following the implant, patients were imaged using CT for post-implant dosimetry. From the pre and post-implant DVHs, the biologically equivalent dose and the tumor control probability (TCP) were determined using the biologically effective uniform dose. The model used RBE = 1.75 and α/β = 2 Gy. The prostate volume changed between pre and post implant image sets ranged from -8% to 110%. TCP and the mean dose were reduced up to 21% and 56%, respectively. TCP is observed to decrease as the mean dose decreases to the prostate. The post-implant tumor dose was generally observed to decrease, compared to the planned dose. A critical uniform dose of 130 Gy was established. Below this dose, TCP begins to fall-off. It was also determined that patients with a small prostates were more likely to suffer TCP decrease. The biological effect of post operative prostate growth due to operative trauma in LDR was evaluated using the concept. The post-implant dose was lower than the planned dose due to an increase of prostate volume post-implant. A critical uniform dose of 130 Gy was determined, below which TCP begun to decline.

  3. Temporal variation of dose rate distribution around the Fukushima Daiichi nuclear power station using unmanned helicopter.

    PubMed

    Sanada, Yukihisa; Orita, Tadashi; Torii, Tatsuo

    2016-12-01

    Aerial radiological survey using an unmanned aerial vehicle (UAV) was applied to measurement surface contamination around the Fukushima Daiichi nuclear power station (FDNPS). An unmanned helicopter monitoring system (UHMS) was developed to survey the environmental effect of radioactive cesium scattered as a result of the FDNPS accident. The UHMS was used to monitor the area surrounding the FDNPS six times from 2012 to 2015. Quantitative changes in the radioactivity distribution trend were revealed from the results of these monitoring runs. With this information, we found that the actual reduction of dose rate was faster than the one calculated with radiocesium physical half-life. It is indicated that the attenuation effect of radiation by radiocesium penetration in soil is dominant as for reason of reduction of dose rate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Hemodynamic Changes by Drug Interaction of Adrenaline With Chlorpromazine

    PubMed Central

    Higuchi, Hitoshi; Yabuki, Akiko; Ishii-Maruhama, Minako; Tomoyasu, Yumiko; Maeda, Shigeru; Miyawaki, Takuya

    2014-01-01

    Adrenaline (epinephrine) is included in dental local anesthesia for the purpose of vasoconstriction. In Japan, adrenaline is contraindicated for use in patients receiving antipsychotic therapy, because the combination of adrenaline and an antipsychotic is considered to cause severe hypotension; however, there is insufficient evidence supporting this claim. The purpose of the present study was to clarify the changes in hemodynamics caused by drug interaction between adrenaline and an antipsychotic and to evaluate the safety of the combined use of adrenaline and an antipsychotic in an animal study. Male Sprague-Dawley rats were anesthetized with sodium pentobarbital. A catheter was inserted into the femoral artery to measure blood pressure and pulse rate. Rats were pretreated by intraperitoneal injection of chlorpromazine or chlorpromazine and propranolol, and after 20 minutes, saline or 1 of 3 different doses of adrenaline was administered by intraperitoneal injection. Changes in the ratio of mean arterial blood pressure and pulse rate were measured after the injection of adrenaline. Significant hypotension and tachycardia were observed after the injection of adrenaline in the chlorpromazine-pretreated rats. These effects were in a dose-dependent manner, and 100 μg/kg adrenaline induced significant hemodynamic changes. Furthermore, in the chlorpromazine and propranolol–pretreated rats, modest hypertension was induced by adrenaline, but hypotension and tachycardia were not significantly shown. Hypotension was caused by a drug interaction between adrenaline and chlorpromazine through the activation of the β-adrenergic receptor and showed a dose-dependent effect. Low-dose adrenaline similar to what might be used in human dental treatment did not result in a significant homodynamic change. PMID:25517550

  5. Hemodynamic changes by drug interaction of adrenaline with chlorpromazine.

    PubMed

    Higuchi, Hitoshi; Yabuki, Akiko; Ishii-Maruhama, Minako; Tomoyasu, Yumiko; Maeda, Shigeru; Miyawaki, Takuya

    2014-01-01

    Adrenaline (epinephrine) is included in dental local anesthesia for the purpose of vasoconstriction. In Japan, adrenaline is contraindicated for use in patients receiving antipsychotic therapy, because the combination of adrenaline and an antipsychotic is considered to cause severe hypotension; however, there is insufficient evidence supporting this claim. The purpose of the present study was to clarify the changes in hemodynamics caused by drug interaction between adrenaline and an antipsychotic and to evaluate the safety of the combined use of adrenaline and an antipsychotic in an animal study. Male Sprague-Dawley rats were anesthetized with sodium pentobarbital. A catheter was inserted into the femoral artery to measure blood pressure and pulse rate. Rats were pretreated by intraperitoneal injection of chlorpromazine or chlorpromazine and propranolol, and after 20 minutes, saline or 1 of 3 different doses of adrenaline was administered by intraperitoneal injection. Changes in the ratio of mean arterial blood pressure and pulse rate were measured after the injection of adrenaline. Significant hypotension and tachycardia were observed after the injection of adrenaline in the chlorpromazine-pretreated rats. These effects were in a dose-dependent manner, and 100 μg/kg adrenaline induced significant hemodynamic changes. Furthermore, in the chlorpromazine and propranolol-pretreated rats, modest hypertension was induced by adrenaline, but hypotension and tachycardia were not significantly shown. Hypotension was caused by a drug interaction between adrenaline and chlorpromazine through the activation of the β-adrenergic receptor and showed a dose-dependent effect. Low-dose adrenaline similar to what might be used in human dental treatment did not result in a significant homodynamic change.

  6. Galactic and solar radiation exposure to aircrew during a solar cycle.

    PubMed

    Lewis, B J; Bennett, L G I; Green, A R; McCall, M J; Ellaschuk, B; Butler, A; Pierre, M

    2002-01-01

    An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of aircrew during a solar cycle. A semi-empirical model has been derived from these data to allow for the interpolation of the dose rate for any global position. The model has been extended to an altitude of up to 32 km with further measurements made on board aircraft and several balloon flights. The effects of changing solar modulation during the solar cycle are characterised by correlating the dose rate data to different solar potential models. Through integration of the dose-rate function over a great circle flight path or between given waypoints, a Predictive Code for Aircrew Radiation Exposure (PCAIRE) has been further developed for estimation of the route dose from galactic cosmic radiation exposure. This estimate is provided in units of ambient dose equivalent as well as effective dose, based on E/H x (10) scaling functions as determined from transport code calculations with LUIN and FLUKA. This experimentally based treatment has also been compared with the CARI-6 and EPCARD codes that are derived solely from theoretical transport calculations. Using TEPC measurements taken aboard the International Space Station, ground based neutron monitoring, GOES satellite data and transport code analysis, an empirical model has been further proposed for estimation of aircrew exposure during solar particle events. This model has been compared to results obtained during recent solar flare events.

  7. Heart Rate Variability (HRV) modifications in adult hemiplegic patients after botulinum toxin type A (nt-201) injection.

    PubMed

    Invernizzi, M; Carda, S; Molinari, C; Stagno, D; Cisari, C; Baricich, A

    2015-08-01

    The most important adverse effect of BoNT-A is the systemic diffusion of the toxin. There is some evidence that the administration of high doses can increase the risk of systemic diffusion and the development of clinically evident adverse effects, however an international consensus does not exist about its maximum dose. The aim of this study was to evaluate changes in autonomic heart drive induced by high doses (higher than 600 units) of incobotulinumtoxinA injection in spastic stroke patients. Moreover, the treatment safety by monitoring adverse events occurrence was assessed. Case control study. Eleven stroke survivors with spastic hemiplegia. Patients were treated with intramuscular focal injections of IncobotulinumtoxinA (NT 201; Xeomin®, Merz Pharmaceuticals GmbH, Frankfurt, Germany). Doses were below 12 units/Kg. Each patient underwent an ECG recording before injection and 10 days after treatment. Linear and non-linear Heart Rate variability (HRV) measures were derived from ECGs with a dedicated software. None of the variable considered showed statistically significant changes after BoNT-A injection. The use of incobotulinumtoxinA in adult patients at doses up to 12 units/kg seems to be safe regarding autonomic heart drive. The use of IncobotulinumtoxinA up to 600 units could be a safe therapeutic option in spastic hemiplegic stroke survivors.

  8. uSIMPK. An Excel for Windows-based simulation program for instruction of basic pharmacokinetics principles to pharmacy students.

    PubMed

    Brocks, Dion R

    2015-07-01

    Pharmacokinetics can be a challenging topic to teach due to the complex relationships inherent between physiological parameters, mathematical descriptors and equations, and their combined impact on shaping the blood fluid concentration vs. time curves of drugs. A computer program was developed within Microsoft Excel for Windows, designed to assist in the instruction of basic pharmacokinetics within an entry-to-practice pharmacy class environment. The program is composed of a series of spreadsheets (modules) linked by Visual Basic for Applications, intended to illustrate the relationships between pharmacokinetic and in some cases physiological parameters, doses and dose rates and the drug blood fluid concentration vs. time curves. Each module is accompanied by a simulation user's guide, prompting the user to change specific independent parameters and then observe the impact of the change(s) on the drug concentration vs. time curve and on other dependent parameters. "Slider" (or "scroll") bars can be selected to readily see the effects of repeated changes on the dependencies. Topics covered include one compartment single dose administration (iv bolus, oral, short infusion), intravenous infusion, repeated doses, renal and hepatic clearance, nonlinear elimination, two compartment model, plasma protein binding and the relationship between pharmacokinetics and drug effect. The program has been used in various forms in the classroom over a number of years, with positive ratings generally being received from students for its use in the classroom. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Effectiveness and gastrointestinal tolerability during conversion and titration with once-daily OROS® hydromorphone extended release in opioid-tolerant patients with chronic low back pain

    PubMed Central

    Hale, Martin E; Nalamachu, Srinivas R; Khan, Arif; Kutch, Michael

    2013-01-01

    Purpose To describe the efficacy and safety of hydromorphone extended-release tablets (OROS hydromorphone ER) during dose conversion and titration. Patients and methods A total of 459 opioid-tolerant adults with chronic moderate to severe low back pain participated in an open-label, 2- to 4-week conversion/titration phase of a double-blind, placebo-controlled, randomized withdrawal trial, conducted at 70 centers in the United States. Patients were converted to once-daily OROS hydromorphone ER at 75% of the equianalgesic dose of their prior total daily opioid dose (5:1 conversion ratio), and titrated as frequently as every 3 days to a maximum dose of 64 mg/day. The primary outcome measure was change in pain intensity numeric rating scale; additional assessments included the Patient Global Assessment and the Roland–Morris Disability Questionnaire scores. Safety assessments were performed at each visit and consisted of recording and monitoring all adverse events (AEs) and serious AEs. Results Mean (standard deviation) final daily dose of OROS hydromorphone ER was 37.5 (17.8) mg. Mean (standard error of the mean [SEM]) numeric rating scale scores decreased from 6.6 (0.1) at screening to 4.3 (0.1) at the final titration visit (mean [SEM] change, −2.3 [0.1], representing a 34.8% reduction). Mean (SEM) change in Patient Global Assessment was −0.6 (0.1), and mean change (SEM) in the Roland–Morris Disability Questionnaire was −2.8 (0.3). Patients achieving a stable dose showed greater improvement than patients who discontinued during titration for each of these measures (P < 0.001). Almost 80% of patients achieving a stable dose (213/268) had a ≥30% reduction in pain. Commonly reported AEs were constipation (15.4%), nausea (11.9%), somnolence (8.7%), headache (7.8%), and vomiting (6.5%); 13.0% discontinued from the study due to AEs. Conclusion The majority of opioid-tolerant patients with chronic low back pain were successfully converted to effective doses of OROS hydromorphone ER within 2 to 4 weeks. PMID:23658495

  10. Cost-effectiveness of allopurinol and febuxostat for the management of gout.

    PubMed

    Jutkowitz, Eric; Choi, Hyon K; Pizzi, Laura T; Kuntz, Karen M

    2014-11-04

    Gout is the most common inflammatory arthritis in the United States. To evaluate the cost-effectiveness of urate-lowering treatment strategies for the management of gout. Markov model. Published literature and expert opinion. Patients for whom allopurinol or febuxostat is a suitable initial urate-lowering treatment. Lifetime. Health care payer. 5 urate-lowering treatment strategies were evaluated: no treatment; allopurinol- or febuxostat-only therapy; allopurinol-febuxostat sequential therapy; and febuxostat-allopurinol sequential therapy. Two dosing scenarios were investigated: fixed dose (80 mg of febuxostat daily, 0.80 success rate; 300 mg of allopurinol daily, 0.39 success rate) and dose escalation (≤120 mg of febuxostat daily, 0.82 success rate; ≤800 mg of allopurinol daily, 0.78 success rate). Discounted costs, discounted quality-adjusted life-years, and incremental cost-effectiveness ratios. In both dosing scenarios, allopurinol-only therapy was cost-saving. Dose-escalation allopurinol-febuxostat sequential therapy was more costly but more effective than dose-escalation allopurinol therapy, with an incremental cost-effectiveness ratio of $39 400 per quality-adjusted life-year. The relative rankings of treatments did not change. Our results were relatively sensitive to several potential variations of model assumptions; however, the cost-effectiveness ratios of dose escalation with allopurinol-febuxostat sequential therapy remained lower than the willingness-to-pay threshold of $109 000 per quality-adjusted life-year. Long-term outcome data for patients with gout, including medication adherence, are limited. Allopurinol single therapy is cost-saving compared with no treatment. Dose-escalation allopurinol-febuxostat sequential therapy is cost-effective compared with accepted willingness-to-pay thresholds. Agency for Healthcare Research and Quality.

  11. [Radioecological studies of freshwater mollusks in the Chernobyl accident exclusion zone].

    PubMed

    Gudkov, D I; Nazarov, A B; Dziubenko, E V; Kaglian, A E; Klenus, V G

    2009-01-01

    Species-specificity and dynamics of 90Sr, 137Cs and some transuranic elements accumulation in bivalve and gastropod freshwater molluscs of the Chernobyl exclusion zone during 1997-2008 was analyzed. The results of radiation dose and chromosome aberration rate estimation and the analysis of hemolymph composition of freshwater snail (Lymnaea stagnalis L.) was produced. The absorbed dose rate was registered in the range of 0.3-85.0 microGy/h. In closed water bodies the heightened chromosome aberration rate (up to 27%) in embryo tissues, and also the change of haematological indexes for the adult individuals of snails was registered.

  12. Space radiation absorbed dose distribution in a human phantom

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Atwell, W.; Badavi, F. F.; Yang, T. C.; Cleghorn, T. F.

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

  13. Advantages of Reduced Prophylaxis after Tubularized Incised Plate Repair of Hypospadias.

    PubMed

    Zeiai, Said; Nordenskjöld, Agneta; Fossum, Magdalena

    2016-10-01

    Concerns about antibiotic resistance, adverse drug reactions and questionable medical benefits have led to changes in prophylactic antibiotic management in hypospadias repair at our clinic. In March 2010 our guidelines were changed from continuous prophylaxis for 14 days to 1 dose preoperatively and another at removal of the stent. We analyze the effects of this new regimen. We performed a prospective journal cohort study of all our hypospadias operations from June 2008 to December 2011. We collected data from consecutive patients undergoing primary tubularized incised plate repair and postoperative stent. Patients operated on before March 2010 were compared to those operated on later. End points were postoperative infection requiring antibiotics and any complication that required redo surgery. The study included 113 primary tubularized incised plate repairs with postoperative stents. Patient distribution was the same in both groups. Of 58 patients in the group receiving continuous antibiotic prophylaxis 17 had a complication and/or infection, compared to 9 of 55 patients receiving 2-dose prophylaxis. The infection rate was 5% in the continuous prophylaxis group and 4% in the 2-dose group. In contrast to our expectations, a lower complication rate was observed in the group with lower antibiotic dose without an increased risk of infection. There is little documented evidence concerning benefits of antibiotic prophylaxis for postoperative complications, which gives rise to large variations in clinical practice. In our study lower antibiotic dose did not increase the number of infections, but rather decreased complication rates. We advocate antibiotic prophylaxis with only a 2-dose regimen. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Monte Carlo simulations of radioactive waste encapsulated by bisphenol-A polycarbonate and effect of bismuth-III oxide filler material

    NASA Astrophysics Data System (ADS)

    Özdemir, Tonguç

    2017-06-01

    Radioactive waste generated from the nuclear industry and non-power applications should carefully be treated, conditioned and disposed according to the regulations set by the competent authority(ies). Bisphenol-a polycarbonate (BPA-PC), a very widely used polymer, might be considered as a potential candidate material for low level radioactive waste encapsulation. In this work, the dose rate distribution in the radioactive waste drum (containing radioactive waste and the BPA-PC polymer matrix) was determined using Monte Carlo simulations. Moreover, the change of mechanical properties of BPA-PC was estimated and their variation within the waste drum was determined for the periods of 15, 30 and 300 years after disposal to the final disposal site. The change of the dose rate within the waste drum with different contents of bismuth-III oxide were also simulated. It was concluded that addition of bismuth-III oxide filler decreases the dose delivered to the polymeric matrix due to photoelectric effect.

  15. Sensory evaluation by gamma radiation effect on protein allergen of laying hen eggs

    NASA Astrophysics Data System (ADS)

    Harder, M. N. C.; Arthur, V.; Perina, V. C. S.; Silva, L. C. A. S.; Bortoleto, G. G.

    2012-08-01

    Although considered the most complete food and nutritionally shown to be part of a healthy diet, the egg is the source of many eating disorders, especially for infants. Irradiation has been used in studies not only as a means of microbiological control, but also on its structural action in the substances molecules and has been used to reduce the allergenic effects. The aim of this study was to evaluate the sensory effects of Co60 gamma radiation on proteins, enabling the acceptability of allergy food for genetically intolerant people. Eggs commercial fresh and freeze-dried and subjected to gamma irradiation by Co60 source at doses 0 (control), 10 kGy; 20 kGy and 30 kGy and rates of doses of 19.4 kGy/h and 31.8 kGy/h. Acceptability test was used by the hedonic scale, since it is necessary to know the "affective status" of consumers for the product, implying a preference, i.e. the most preferred samples are the most accepted and vice versa. The samples were presented as the habit of consumption (cooked) to a group of 41 adults panelists of both gender, aged from 21 to 40 years, and served under complete block design balanced with respect to the order of presentation. The evaluated attributes was flavor, appearance and overall acceptability. In general, for boiled eggs and freeze-dried, it was observed that the control sample was the most acceptable, followed by the sample irradiated with 10 kGy in both dose rates. In addition, panelists presented in testimony that they found interesting changes due to irradiation; also said they would not buy the product because of the marked change in appearance and smell, which at one point he ended up in disgust and detract from sales of the product, but they would buy irradiated with 10 kGy in both dose rate and dose of 20 kGy at a dose rate of 19.4 kGy/h.

  16. Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C

    NASA Technical Reports Server (NTRS)

    Yukihara, E. G.; Whitley, V. H.; McKeever, S. W. S.; Akselrod, A. E.; Akselrod, M. S.

    2004-01-01

    This paper examines the effect of high-dose irradiation on the optically stimulated luminescence (OSL) of Al2O3:C, principally on the shape of the OSL decay curve and on the OSL sensitivity. The effect of the degree of deep trap filling on the OSL was also studied by monitoring the sensitivity changes after doses of beta irradiation and after step-annealing of samples previously irradiated with high doses. The OSL response to dose shows a linear-supralinear-saturation behavior, with a decrease in the response for doses higher than those required for saturation. This behavior correlates with the sensitivity changes observed in the samples annealed only to 773 K, which show sensitization for doses up to 20-50 Gy and desensitization for higher doses. Data from the step-annealing study leads to the suggestion that the sensitization is caused by the filling of deep electron traps, which become thermally unstable at 1100-1200 K, whereas the desensitization is caused by the filling of deep hole traps, which become thermally unstable at 800-875 K, along with a concomitant decrease in the concentration of recombination centers (F+ -centers). Changes in the shape of the OSL decay curves are also observed at high doses, the decay becoming faster as the dose increases. These changes in the OSL decay curves are discussed in terms of multiple overlapping components, each characterized by different photoionization cross-sections. However, using numerical solutions of the rate equations for a simple model consisting of a main trap and a recombination center, it is shown that the kinetics of OSL process may also be partially responsible for the changes in the OSL curves at high doses in Al2O3:C. Finally, the implication of these results for the dosimetry of heavy charged particles is discussed. c2004 Elsevier Ltd. All rights reserved.

  17. Comparison of TID Effects in Space-Like Variable Dose Rates and Constant Dose Rates

    NASA Technical Reports Server (NTRS)

    Harris, Richard D.; McClure, Steven S.; Rax, Bernard G.; Evans, Robin W.; Jun, Insoo

    2008-01-01

    The degradation of the LM193 dual voltage comparator has been studied at different TID dose rate profiles, including several different constant dose rates and a variable dose rate that simulates the behavior of a solar flare. A comparison of results following constant dose rate vs. variable dose rates is made to explore how well the constant dose rates used for typical part testing predict the performance during a simulated space-like mission. Testing at a constant dose rate equal to the lowest dose rate seen during the simulated flare provides an extremely conservative estimate of the overall amount of degradation. A constant dose rate equal to the average dose rate is also more conservative than the variable rate. It appears that, for this part, weighting the dose rates by the amount of total dose received at each rate (rather than the amount of time at each dose rate) results in an average rate that produces an amount of degradation that is a reasonable approximation to that received by the variable rate.

  18. Exercise-Induced Dose-Response Alterations in Adiponectin and Leptin Levels Are Dependent on Body Fat Changes in Women at Risk for Breast Cancer.

    PubMed

    Sturgeon, Kathleen; Digiovanni, Laura; Good, Jerene; Salvatore, Domenick; Fenderson, Desiré; Domchek, Susan; Stopfer, Jill; Galantino, Mary Lou; Bryan, Cathy; Hwang, Wei-Ting; Schmitz, Kathryn

    2016-08-01

    Dysregulation of adipokines, such as adiponectin and leptin, is associated with a variety of chronic diseases, including cancer. Physical activity protects against breast cancer and one of the mechanisms which may underlie this association is exercise-induced changes in adipokine levels. The WISER Sister Trial was a three-armed randomized controlled trial in premenopausal women (n = 137) with an elevated risk for breast cancer. A 5-menstrual-cycle-long dosed aerobic exercise intervention compared low-dose exercise (150 min/wk; n = 44) or high-dose exercise (300 min/wk; n = 48) with a control group asked to maintain usual activity levels (n = 45). Exercise intensity progressed to and was maintained at 70% to 80% of age predicted heart rate max. Body composition and adipokine levels were measured at baseline and follow-up. We observed significant linear trends for increased fitness capacity (Δ%: -2.0% control, 10.1% low dose, 13.1% high dose), decreased fat tissue-to-total tissue mass (Δ%: 0.7% control, -2.9% low dose, -3.7% high dose), increased body fat adjusted adiponectin (Δ%: -0.6% control, 0.6% low dose, 0.9% high dose), and decreased body fat adjusted leptin (Δ%: 0.7% control, -8.2% low dose, -10.2% high dose). In this randomized clinical trial of premenopausal women at risk for breast cancer, we demonstrate a dose-response effect of exercise on adiponectin and leptin and that dose response is dependent on changes in body fat. Improved adipokine levels, achieved by aerobic exercise training-induced decreases in body fat, may decrease breast cancer risk for high-risk premenopausal women. Cancer Epidemiol Biomarkers Prev; 25(8); 1195-200. ©2016 AACR. ©2016 American Association for Cancer Research.

  19. Demonstration of an adaptive response to preconditioning Frankliniella occidentalis (Pergande) to sublethal doses of spinosad: a hormetic-dose response.

    PubMed

    Gong, Youhui; Xu, Baoyun; Zhang, Youjun; Gao, Xiwu; Wu, Qingjun

    2015-07-01

    Sublethal doses of some insecticides have been reported to either stimulate or reduce the survival and fecundity of insects. Many sublethal-effect studies have been conducted after exposure of only one generation to sublethal insecticides, and there is little information about the sublethal effects on insects after long-term exposure to sublethal insecticides. In this study, changes in biological characteristics were investigated in spinosad-susceptible (Spin-S) and sublethal-spinosad-treated (Spin-Sub) strains of Frankliniella occidentalis (Pergande) after exposure to their corresponding sublethal concentrations of spinosad. The results showed that for the Spin-S strain, the LC10 concentration of spinosad slightly affected the biotic fitness both in parents and offspring of F. occidentalis. The LC25 concentration of spinosad prolonged the development time, reduced the fecundity, and significantly reduced the intrinsic rate of increase, the net reproductive rate and the finite rate of increase in the Spin-S strain. However, the negative effects were not as pronounced in the offspring (F1 generation) as in the parent generation. For the Spin-Sub strain, the LC10 and LC25 concentrations of spinosad had little negative effect on the development and fecundity, and no significant difference was found between the effects of the LC10 and LC25 treatments on the Spin-Sub strain. The Spin-Sub strain exhibited a shorter developmental time, and larger intrinsic rates of increase and net reproductive rates, compared with the corresponding treatments of the Spin-S strain. These findings combined with our previous studies suggest that the biotic fitness increased in the Spin-Sub strain and the strain became more adaptable to sublethal doses of spinosad, compared with the Spin-S strain. Physiological and biochemical adaptation may contribute to these changes after long treatment times at sublethal doses.

  20. Effects of changing heart rate on electrophysiological and hemodynamic function in the dog.

    PubMed

    Hamlin, Robert L; Nakayama, Tomohiro; Nakayama, Hitomi; Carnes, Cynthia A

    2003-03-14

    Cardiovascular parameters were measured in dogs after RR interval was changed from 0.25 s to 1.2 s with atropine and graded doses of zatebradine, an I(f)-channel blocker. Left ventricular (LV) pre-ejection period (PEP), systemic vascular resistance, tau (an estimate of myocardial stiffness), PQ, QTc, dLVP/dt(max) and dLVP/dt(min), aortic pressure, and right atrial pressure did not change when each parameter was plotted against RR interval (r(2)'s < or = 0.5). LV end-diastolic pressure, stroke volume index, LV ejection time (ET), and QT all increased either linearly or curvilinearly as RR interval prolonged. Cardiac output index and PEP/ET decreased curvilinearly. When heart rate (HR) was fixed by pacing, and graded doses of zatebradine were given, changes in cardiovascular function were minimal. Thus zatebradine affects cardiovascular function principally by changing HR and not by affecting function directly. This study provides data on the effects of changing HR, alone, on cardiovascular parameters measured frequently during pharmacological and toxicological studies. It should prove useful when physiological variables, including HR, change, and there is need to know what change in HR, alone, contributes.

  1. High dose-per-pulse electron beam dosimetry: Commissioning of the Oriatron eRT6 prototype linear accelerator for preclinical use.

    PubMed

    Jaccard, Maud; Durán, Maria Teresa; Petersson, Kristoffer; Germond, Jean-François; Liger, Philippe; Vozenin, Marie-Catherine; Bourhis, Jean; Bochud, François; Bailat, Claude

    2018-02-01

    The Oriatron eRT6 is an experimental high dose-per-pulse linear accelerator (linac) which was designed to deliver an electron beam with variable dose-rates, ranging from a few Gy/min up to hundreds of Gy/s. It was built to study the radiobiological effects of high dose-per-pulse/dose-rate electron beam irradiation, in the context of preclinical and cognitive studies. In this work, we report on the commissioning and beam monitoring of the Oriatron eRT6 prototype linac. The beam was characterized in different steps. The output stability was studied by performing repeated measurements over a period of 20 months. The relative output variations caused by changing beam parameters, such as the temporal electron pulse width, the pulse repetition frequency and the pulse amplitude were also analyzed. Finally, depth dose curves and field sizes were measured for two different beam settings, resulting in one beam with a conventional radiotherapy dose-rate and one with a much higher dose-rate. Measurements were performed with Gafchromic EBT3 films and with a PTW Advanced Markus ionization chamber. In addition, we developed a beam current monitoring system based on the signals from an induction torus positioned at the beam exit of the waveguide and from a graphite beam collimator. The stability of the output over repeated measurements was found to be good, with a standard deviation smaller than 1%. However, non-negligible day-to-day variations of the beam output were observed. Those output variations showed different trends depending on the dose-rate. The analysis of the relative output variation as a function of various beam parameters showed that in a given configuration, the dose-rate could be reliably varied over three orders of magnitude. Interdependence effects on the output variation between the parameters were also observed. The beam energy and field size were found to be slightly dose-rate-dependent and suitable mainly for small animal irradiation. The beam monitoring system was able to measure in a reproducible way the total charge of electrons that exit the machine, as long as the electron pulse amplitude remains above a given threshold. Furthermore, we were able to relate the charge measured with the monitoring system to the absorbed dose in a solid water phantom. The Oriatron eRT6 was successfully commissioned for preclinical use and is currently in full operation, with studies being performed on the radiobiological effects of high dose-per-pulse irradiation. © 2017 American Association of Physicists in Medicine.

  2. SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, D; Braunstein, S; Sneed, P

    Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkagemore » rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.« less

  3. Self-Regulation of Visual Attention and Facial Expression of Emotions in ADHD Children

    ERIC Educational Resources Information Center

    Kuhle, Hans J.; Kinkelbur, Jorg; Andes, Kerstin; Heidorn, Fridjof M.; Zeyer, Solveigh; Rautzenberg, Petra; Jansen, Fritz

    2007-01-01

    Objective: To test if visual focusing and mimic display as features of self-regulation in ADHD children show a curvilinear relation to rising methylphenidate (MPH) doses. To test if small dose steps of 2.5mg MPH cause significant changes in behavior. And to test the relation of these features to intellectual performance, parents' ratings, and…

  4. Increase in sensitivity of the baroreceptor reflex following microinjection of carbachol into the posterior hypothalamic nucleus of awake rats.

    PubMed

    Newey, C R; Martin, J R

    2016-01-01

    In a rat model, the baroreceptor reflex can be assessed by graded infusions of either phenylephrine or sodium nitroprusside with continuous hemodynamic monitoring. Microinjection of the cholinergic agonist carbachol (CCh) into the posterior hypothalamic nucleus (PHN) evokes an increase in mean arterial pressure and a change in heart rate. Lower doses of CCh evoke only tachycardia, whereas middle and higher doses evoke a biphasic change in heart rate of tachycardia followed by bradycardia. The bradycardia following the microinjection of CCh into the PHN can be attenuated by the previous administration of the vasopressin V1 receptor antagonist [d(CH2 )5 Tyr(Me)] arginine vasopressin (AVPX). Circulating arginine vasopressin (AVP) has been shown to increase the sensitivity of the baroreceptor reflex by stimulating vasopressin V1 receptors in the area postrema. The attenuation by AVPX of the bradycardia that results following the high doses of CCh suggests that AVP is released into the circulation following stimulation of cholinergic systems within the PHN. Thus, microinjection of a high dose of CCh (11 nmol) into the PHN alters the sensitivity of the baroreceptor reflex by increasing peripheral levels of AVP. © 2016 John Wiley & Sons Ltd.

  5. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting.

    PubMed

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13.

  6. External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting

    PubMed Central

    Yoo, Song Jae; Jang, Han-Ki; Lee, Jai-Ki; Noh, Siwan; Cho, Gyuseong

    2013-01-01

    For the assessment of external doses due to contaminated environment, the dose-rate conversion factors (DCFs) prescribed in Federal Guidance Report 12 (FGR 12) and FGR 13 have been widely used. Recently, there were significant changes in dosimetric models and parameters, which include the use of the Reference Male and Female Phantoms and the revised tissue weighting factors, as well as the updated decay data of radionuclides. In this study, the DCFs for effective and equivalent doses were calculated for three exposure settings: skyshine, groundshine and water immersion. Doses to the Reference Phantoms were calculated by Monte Carlo simulations with the MCNPX 2.7.0 radiation transport code for 26 mono-energy photons between 0.01 and 10 MeV. The transport calculations were performed for the source volume within the cut-off distances practically contributing to the dose rates, which were determined by a simplified calculation model. For small tissues for which the reduction of variances are difficult, the equivalent dose ratios to a larger tissue (with lower statistical errors) nearby were employed to make the calculation efficient. Empirical response functions relating photon energies, and the organ equivalent doses or the effective doses were then derived by the use of cubic-spline fitting of the resulting doses for 26 energy points. The DCFs for all radionuclides considered important were evaluated by combining the photon emission data of the radionuclide and the empirical response functions. Finally, contributions of accompanied beta particles to the skin equivalent doses and the effective doses were calculated separately and added to the DCFs. For radionuclides considered in this study, the new DCFs for the three exposure settings were within ±10 % when compared with DCFs in FGR 13. PMID:23542764

  7. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Safari, M. J.; Wong, J. H. D.; Ng, K. H., E-mail: ngkh@um.edu.my

    2015-05-15

    Purpose: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. Methods: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualitiesmore » were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. Results: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (±1%), field size (±1%), frame rate (±3%), or beam energy (±5%). The detector angular dependence was within ±5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ±3%. Conclusions: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.« less

  8. Characterization of a MOSkin detector for in vivo skin dose measurements during interventional radiology procedures.

    PubMed

    Safari, M J; Wong, J H D; Ng, K H; Jong, W L; Cutajar, D L; Rosenfeld, A B

    2015-05-01

    The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (± 1%), field size (± 1%), frame rate (± 3%), or beam energy (± 5%). The detector angular dependence was within ± 5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ± 3%. The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.

  9. Radiation induced degradation of xanthan gum in aqueous solution

    NASA Astrophysics Data System (ADS)

    Hayrabolulu, Hande; Demeter, Maria; Cutrubinis, Mihalis; Güven, Olgun; Şen, Murat

    2018-03-01

    In our previous study, we have investigated the effect of gamma rays on xanthan gum in the solid state and it was determined that dose rate was an important factor effecting the radiation degradation of xanthan gum. In the present study, in order to provide a better understanding of how ionizing radiation effect xanthan gum, we have investigated the effects of ionizing radiation on aqueous solutions of xanthan at various concentrations (0.5-4%). Xanthan solutions were irradiated with gamma rays in air, at ambient temperature, at different dose rates (0.1-3.3-7.0 kGy/h) and doses (2.5-50 kGy). Change in their molecular weights was followed by size exclusion chromatography (SEC). Chain scission yield (G(S)), and degradation rate constants (k) were calculated. It was determined that, solution concentration was a factor effecting the degradation chemical yield and degradation rate of xanthan gum. Chain scission reactions were more effective for lower solution concentrations.

  10. Solar particle dose rate buildup and distribution in critical body organs

    NASA Technical Reports Server (NTRS)

    Atwell, William; Weyland, Mark D.; Simonsen, Lisa C.

    1993-01-01

    Human body organs have varying degrees of radiosensitivity as evidenced by radioepidemiologic tables. The major critical organs for both the male and female that have been identified include the lung, thyroid, stomach, and breast (female). Using computerized anatomical models of the 50th percentile United States Air Force male and female, we present the self-shielding effects of these various body organs and how the shielding effects change as the location (dose point) in the body varies. Several major solar proton events from previous solar cycles and several events from the current 22nd solar cycle have been analyzed. The solar particle event rise time, peak intensity, and decay time vary considerably from event to event. Absorbed dose and dose equivalent rate calculations and organ risk assessment data are presented for each critical body organ. These data are compared with the current NASA astronaut dose limits as recommended by the National Council on Radiation Protection and Measurements.

  11. Characterization of the radiation environment for a large-area interim spent-nuclear-fuel storage facility

    NASA Astrophysics Data System (ADS)

    Fortkamp, Jonathan C.

    Current needs in the nuclear industry and movements in the political arena indicate that authorization may soon be given for development of a federal interim storage facility for spent nuclear fuel. The initial stages of the design work have already begun within the Department of Energy and are being reviewed by the Nuclear Regulatory Commission. This dissertation addresses the radiation environment around an interim spent nuclear fuel storage facility. Specifically the dissertation characterizes the radiation dose rates around the facility based on a design basis source term, evaluates the changes in dose due to varying cask spacing configurations, and uses these results to define some applicable health physics principles for the storage facility. Results indicate that dose rates from the facility are due primarily from photons from the spent fuel and Co-60 activation in the fuel assemblies. In the modeled cask system, skyshine was a significant contribution to dose rates at distances from the cask array, but this contribution can be reduced with an alternate cask venting system. With the application of appropriate health physics principles, occupation doses can be easily maintained far below regulatory limits and maintained ALARA.

  12. A dose assessment method for arbitrary geometries with virtual reality in the nuclear facilities decommissioning

    NASA Astrophysics Data System (ADS)

    Chao, Nan; Liu, Yong-kuo; Xia, Hong; Ayodeji, Abiodun; Bai, Lu

    2018-03-01

    During the decommissioning of nuclear facilities, a large number of cutting and demolition activities are performed, which results in a frequent change in the structure and produce many irregular objects. In order to assess dose rates during the cutting and demolition process, a flexible dose assessment method for arbitrary geometries and radiation sources was proposed based on virtual reality technology and Point-Kernel method. The initial geometry is designed with the three-dimensional computer-aided design tools. An approximate model is built automatically in the process of geometric modeling via three procedures namely: space division, rough modeling of the body and fine modeling of the surface, all in combination with collision detection of virtual reality technology. Then point kernels are generated by sampling within the approximate model, and when the material and radiometric attributes are inputted, dose rates can be calculated with the Point-Kernel method. To account for radiation scattering effects, buildup factors are calculated with the Geometric-Progression formula in the fitting function. The effectiveness and accuracy of the proposed method was verified by means of simulations using different geometries and the dose rate results were compared with that derived from CIDEC code, MCNP code and experimental measurements.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, Swarajit N., E-mail: snghosh@mcw.ed; Zhang Rong; Department of Pharmacology, Harbin Medical University College of Pharmacy, Harbin

    Purpose: To find the mitigators of pneumonitis induced by moderate doses of thoracic radiation (10-15 Gy). Methods and Materials: Unanesthetized WAG/RijCmcr female rats received a single dose of X-irradiation (10, 12, or 15 Gy at 1.615 Gy/min) to the thorax. Captopril (an angiotensin-converting enzyme inhibitor) or losartan (an angiotensin receptor blocker) was administered in the drinking water after irradiation. Pulmonary structure and function were assessed after 8 weeks in randomly selected rats by evaluating the breathing rate, ex vivo vascular reactivity, and histopathologic findings. Survival analysis was undertaken on all animals, except those scheduled for death. Results: Survival after amore » dose of 10 Gy to the thorax was not different from that of unirradiated rats for <=1 year. Survival decreased to <50% by 45 weeks after 12 Gy and by 8-9 weeks after 15 Gy. Captopril (17-56mg/kg/d) improved survival and reduced radiation-induced increases in breathing rate, changes in vascular reactivity, and histopathologic evidence of injury. Radiation-induced increases in the breathing rate were prevented even if captopril was started 1 week after irradiation or if it was discontinued after 5 weeks. Losartan, although effective in reducing mortality, was not as efficacious as captopril in mitigating radiation-induced increases in the breathing rate or altered vasoreactivity. Conclusion: In rats, a moderate thoracic radiation dose induced pneumonitis and morbidity. These injuries were mitigated by captopril even when it was begun 1 week after radiation or if discontinued 5 weeks after exposure. Losartan was less effective in protecting against radiation-induced changes in vascular reactivity or tachypnea.« less

  14. Dose responses for adaption to low doses of (60)Co gamma rays and (3)H beta particles in normal human fibroblasts.

    PubMed

    Broome, E J; Brown, D L; Mitchel, R E J

    2002-08-01

    The dose response for adaption to radiation at low doses was compared in normal human fibroblasts (AG1522) exposed to either (60)Co gamma rays or (3)H beta particles. Cells were grown in culture to confluence and exposed at either 37 degrees C or 0 degrees C to (3)H beta-particle or (60)Co gamma-ray adapting doses ranging from 0.1 mGy to 500 mGy. These cells, and unexposed control cells, were allowed to adapt during a fixed 3-h, 37 degrees C incubation prior to a 4-Gy challenge dose of (60)Co gamma rays. Adaption was assessed by measuring micronucleus frequency in cytokinesis-blocked, binucleate cells. No adaption was detected in cells exposed to (60)Co gamma radiation at 37 degrees C after a dose of 0.1 mGy given at a low dose rate or to 500 mGy given at a high dose rate. However, low-dose-rate exposure (1-3 mGy/min) to any dose between 1 and 500 mGy from either radiation, delivered at either temperature, caused cells to adapt and reduced the micronucleus frequency that resulted from the subsequent 4-Gy exposure. Within this dose range, the magnitude of the reduction was the same, regardless of the dose or radiation type. These results demonstrate that doses as low as (on average) about one track per cell (1 mGy) produce the same maximum adaptive response as do doses that deposit many tracks per cell, and that the two radiations were not different in this regard. Exposure at a temperature where metabolic processes, including DNA repair, were inactive (0 degrees C) did not alter the result, indicating that the adaptive response is not sensitive to changes in the accumulation of DNA damage within this range. The results also show that the RBE for low doses of tritium beta-particle radiation is 1, using adaption as the end point.

  15. Dosing adjustments in postpartum patients maintained on buprenorphine or methadone.

    PubMed

    Jones, Hendrée E; Johnson, Rolley E; O'Grady, Kevin E; Jasinski, Donald R; Tuten, Michelle; Milio, Lorraine

    2008-06-01

    Scant scientific attention has been given to examining the need for agonist medication dose changes in the postpartum period. Study objectives were: 1) to determine the need for medication dose adjustments in participants stabilized on buprenorphine or methadone 3 weeks before and 4 weeks after delivery, and 2) to evaluate the need for methadone dose adjustments during the first 7 days in participants transferred from buprenorphine to methadone at 5 weeks postpartum. Participants were opioid-dependent pregnant women who had completed a randomized, double-blind, double-dummy, flexible dosing comparison of buprenorphine to methadone. Participants received a stable dose of methadone (N = 10) or buprenorphine (N = 8) before and 4 weeks after delivery. Buprenorphine-maintained participants were transferred to methadone at 5 weeks postpartum. There were no significant differences predelivery and/or postdelivery between the buprenorphine and methadone conditions in the mean ratings of dose adequacy, "liking," "hooked," and "craving" of heroin or cocaine. Patient response to the conversion from buprenorphine to methadone seems variable. Buprenorphine-maintained participants required dose changes postpartum only after they transferred to methadone. Regardless of type of medication, postpartum patients should be monitored for signs of overmedication.

  16. A double-blind, placebo-controlled, randomised, parallel-group, dose-escalating, repeat dose study in healthy volunteers to evaluate the safety, tolerability, pharmacodynamic effects and pharmacokinetics of the once daily rectal application of NRL001 suppositories for 14 days.

    PubMed

    Bell, D; Duffin, A; Jacobs, A; Pediconi, C; Gruss, H J

    2014-03-01

    The 1R,2S stereoisomer of methoxamine hydrochloride, NRL001, is a highly selective α1-adrenoceptor agonist being developed for the local treatment of non-structural faecal incontinence caused by weak internal anal sphincter tone. This study investigated the steady state pharmacokinetics (PK) and safety of 2 g rectal suppositories containing NRL001 in different strengths (7.5, 10, 12.5 or 15 mg). Healthy volunteers aged 18-45 years received 14 daily doses of NRL001 2 g suppositories or matching placebo. In each dose group nine participants received NRL001 and three received placebo. Blood samples to determine NRL001 concentrations were taken on Days 1, 7 and 14. Cardiovascular parameters were collected via electrocardiograms, Holter monitoring (three lead Holter monitor) and vital signs. Forty-eight volunteers were enrolled; 43 completed the study and were included in the PK analysis population. AUC and Cmax broadly increased with increasing dose, Tmax generally occurred between 4.0 and 5.0 h. Although the data did not appear strongly dose proportional, dose proportionality analysis did not provide evidence against dose proportionality as the log(dose) coefficients were not significantly < 1. NRL001 did not accumulate over time for any dose. Increasing NRL001 concentrations were related to changes in vital sign variables, most notably decreased heart rate. The most commonly reported adverse events (AEs) in the active treatment groups were paraesthesia and piloerection. Treatment with NRL001 was generally well tolerated over 14 days once daily dosing and plasma NRL001 did not accumulate over time. Treatment was associated with changes in vital sign variables, most notably decreased heart rate. AEs commonly reported with NRL001 treatment were events indicative of a systemic α-adrenergic effect. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  17. Investigating ion recombination effects in a liquid-filled ionization chamber array used for IMRT QA measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knill, Cory, E-mail: knillcor@gmail.com; Snyder, Michael; Rakowski, Joseph T.

    Purpose: PTW’s Octavius 1000 SRS array performs IMRT quality assurance (QA) measurements with liquid-filled ionization chambers (LICs) to allow closer detector spacing and higher resolution, compared to air-filled QA devices. However, reduced ion mobility in LICs relative to air leads to increased ion recombination effects and reduced collection efficiencies that are dependent on Linac pulse frequency and pulse dose. These pulse parameters are variable during an IMRT delivery, which affects QA results. In this study, (1) 1000 SRS collection efficiencies were measured as a function of pulse frequency and pulse dose, (2) two methods were developed to correct changes inmore » collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: To obtain collection efficiencies, the OCTAVIUS 1000 SRS was used to measure open fields of varying pulse frequency, pulse dose, and beam energy with results normalized to air-filled chamber measurements. Changes in ratios of 1000 SRS to chamber measured dose were attributed to changing collection efficiencies, which were then correlated to pulse parameters using regression analysis. The usefulness of the derived corrections was then evaluated using 6 MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam (Varian Medical Systems) linear accelerator equipped with a high definition multileaf collimator. For the first correction, MATLAB software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information is converted to collection efficiency, and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction the MU/min in the daily 1000 SRS calibration was chosen to match the average MU/min of the volumetric modulated arc therapy plan. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: Collection efficiencies correlated linearly to pulse dose, while correlations with pulse frequency were less defined, generally increasing as pulse frequency decreased. After complex MATLAB corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6 MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6 MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3 mm,2%/2 mm,1%/1 mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex MATLAB corrections. Conclusions: OCTAVIUS 1000 SRS ion recombination effects have little effect on 6 MV measurements. However, the effect could potentially be clinically significant for higher pulse dose unflattened beams when using tighter gamma tolerances, especially when small aperture sizes are used, as is common for SRS/SBRT. In addition, ion recombination effects are strongly correlated to changing MU/min, therefore MU/min used in daily 1000 SRS calibrations should be matched to the expected average MU/min of the IMRT plan.« less

  18. Cumulative Training Dose's Effects on Interrelationships Between Common Training-Load Models During Basketball Activity.

    PubMed

    Scanlan, Aaron T; Fox, Jordan L; Borges, Nattai R; Dascombe, Ben J; Dalbo, Vincent J

    2017-02-01

    The influence of various factors on training-load (TL) responses in basketball has received limited attention. This study aimed to examine the temporal changes and influence of cumulative training dose on TL responses and interrelationships during basketball activity. Ten state-level Australian male junior basketball players completed 4 × 10-min standardized bouts of simulated basketball activity using a circuit-based protocol. Internal TL was quantified using the session rating of perceived exertion (sRPE), summated heart-rate zones (SHRZ), Banister training impulse (TRIMP), and Lucia TRIMP models. External TL was assessed via measurement of mean sprint and circuit speeds. Temporal TL comparisons were performed between 10-min bouts, while Pearson correlation analyses were conducted across cumulative training doses (0-10, 0-20, 0-30, and 0-40 min). sRPE TL increased (P < .05) after the first 10-min bout of basketball activity. sRPE TL was only significantly related to Lucia TRIMP (r = .66-.69; P < .05) across 0-10 and 0-20 min. Similarly, mean sprint and circuit speed were significantly correlated across 0-20 min (r = .67; P < .05). In contrast, SHRZ and Banister TRIMP were significantly related across all training doses (r = .84-.89; P < .05). Limited convergence exists between common TL approaches across basketball training doses lasting beyond 20 min. Thus, the interchangeability of commonly used internal and external TL approaches appears dose-dependent during basketball activity, with various psychophysiological mediators likely underpinning temporal changes.

  19. The effect of low dose rate irradiation on the tensile properties and microstructure of austenitic stainless steel.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allen, T. R.; Tsai, H.; Cole, J. I.

    2002-09-17

    To assess the effects of long-term, low-dose-rate neutron exposure on mechanical strength and ductility, tensile properties were measured on 12% and 20% cold-worked Type 316 stainless steel. Samples were prepared from reactor core components retrieved from the EBR-II reactor following final shutdown. Sample locations were chosen to cover a dose range of 1-56 dpa at temperatures from 371-440 C and dose rates from 0.5-5.8 x10{sup -7} dpa/s. These dose rates are approximately an order of magnitude lower than those of typical EBR-II test sample locations. The tensile tests for the 12% CW material were performed at 380 C and 430more » C while those for the 20% CW samples were performed at 370 C. In each case, the tensile test temperature approximately matched the irradiation temperature. To help understand the tensile properties, microstructural samples with similar irradiation history were also examined. The strength and loss of work hardening increase the fastest as a function of irradiation dose for the 12% CW material irradiated at lower temperature. The decrease in ductility with increasing dose occurs more rapidly for the 12% CW material irradiated at lower temperature and the 20% cold-worked material. Post-tensile test fractography indicates that at higher dose, the 20% CW samples begin a shift in fracture mode from purely ductile to mainly small facets and slip bands, suggesting a transition toward channel fracture. The fracture for all of the 12% cold-worked samples was ductile. For both the 12% and 20% CW materials, the yield strength increases correlate with changes in void and loop density and size.« less

  20. Physiologic variability at the verge of systemic inflammation: multiscale entropy of heart rate variability is affected by very low doses of endotoxin.

    PubMed

    Herlitz, Georg N; Arlow, Renee L; Cheung, Nora H; Coyle, Susette M; Griffel, Benjamin; Macor, Marie A; Lowry, Stephen F; Calvano, Steve E; Gale, Stephen C

    2015-02-01

    Human injury or infection induces systemic inflammation with characteristic neuroendocrine responses. Fluctuations in autonomic function during inflammation are reflected by beat-to-beat variation in heart rate, termed heart rate variability (HRV). In the present study, we determine threshold doses of endotoxin needed to induce observable changes in markers of systemic inflammation, investigate whether metrics of HRV exhibit a differing threshold dose from other inflammatory markers, and investigate the size of data sets required for meaningful use of multiscale entropy (MSE) analysis of HRV. Healthy human volunteers (n = 25) were randomized to receive placebo (normal saline) or endotoxin/lipopolysaccharide (LPS): 0.1, 0.25, 0.5, 1.0, or 2.0 ng/kg administered intravenously. Vital signs were recorded every 30 min for 6 h and then at 9, 12, and 24 h after LPS. Blood samples were drawn at specific time points for cytokine measurements. Heart rate variability analysis was performed using electrocardiogram epochs of 5 min. Multiscale entropy for HRV was calculated for all dose groups to scale factor 40. The lowest significant threshold dose was noted in core temperature at 0.25 ng/kg. Endogenous tumor necrosis factor α and interleukin 6 were significantly responsive at the next dosage level (0.5 ng/kg) along with elevations in circulating leukocytes and heart rate. Responses were exaggerated at higher doses (1 and 2 ng/kg). Time domain and frequency domain HRV metrics similarly suggested a threshold dose, differing from placebo at 1.0 and 2.0 ng/kg, below which no clear pattern in response was evident. By applying repeated-measures analysis of variance across scale factors, a significant decrease in MSE was seen at 1.0 and 2.0 ng/kg by 2 h after exposure to LPS. Although not statistically significant below 1.0 ng/kg, MSE unexpectedly decreased across all groups in an orderly dose-response pattern not seen in the other outcomes. By using repeated-measures analysis of variance across scale factors, MSE can detect autonomic change after LPS challenge in a group of 25 subjects using electrocardiogram epochs of only 5 min and entropy analysis to scale factor of only 40, potentially facilitating MSE's wider use as a research tool or bedside monitor. Traditional markers of inflammation generally exhibit threshold dose behavior. In contrast, MSE's apparent continuous dose-response pattern, although not statistically verifiable in this study, suggests a potential subclinical harbinger of infectious or other insult. The possible derangement of autonomic complexity prior to or independent of the cytokine surge cannot be ruled out. Future investigation should focus on confirmation of overt inflammation following observed decreases in MSE in a clinical setting.

  1. Developmental changes rather than repeated administration drive paracetamol glucuronidation in neonates and infants.

    PubMed

    Krekels, Elke H J; van Ham, Saskia; Allegaert, Karel; de Hoon, Jan; Tibboel, Dick; Danhof, Meindert; Knibbe, Catherijne A J

    2015-09-01

    Based on recovered metabolite ratios in urine, it has been concluded that paracetamol glucuronidation may be up-regulated upon multiple dosing. This study investigates paracetamol clearance in neonates and infants after single and multiple dosing using a population modelling approach. A population pharmacokinetic model was developed in NONMEM VI, based on paracetamol plasma concentrations from 54 preterm and term neonates and infants, and on paracetamol, paracetamol-glucuronide and paracetamol-sulphate amounts in urine from 22 of these patients. Patients received either a single intravenous propacetamol dose or up to 12 repeated doses. Paracetamol and metabolite disposition was best described with one-compartment models. The formation clearance of paracetamol-sulphate was 1.46 mL/min/kg(1.4), which was about 5.5 times higher than the formation clearance of the glucuronide of 0.266 mL/min/kg. The renal excretion rate constants of both metabolites was estimated to be 11.4 times higher than the excretion rate constant of unchanged paracetamol, yielding values of 0.580 mL/min/kg. Developmental changes were best described by bodyweight in linear relationships on the distribution volumes, the formation of paracetamol-glucuronide and the unchanged excretion of paracetamol, and in an exponential relationship on the formation of paracetamol-sulphate. There was no evidence for up-regulation or other time-varying changes in any of the model parameters. Simulations with this model illustrate how paracetamol-glucuronide recovery in urine increases over time due to the slower formation of this metabolite and in the absence of up-regulation. Developmental changes, described by bodyweight-based functions, rather than up-regulation, explain developmental changes in paracetamol disposition in neonates and infants.

  2. Alteration in apoptotic rate of testicular cells and sperms following administration of Bisphenol A (BPA) in Wistar albino rats.

    PubMed

    Srivastava, Seema; Gupta, Priya

    2018-05-21

    The aim of the study was to evaluate the effect of Bisphenol A [BPA] widely used as a plasticizer in the formation of polycarbonate plastics and epoxy resins, exposure causing alteration in apoptosis rate, and protective effect of Vitamin E when supplemented with BPA orally. Adult male Wistar albino rats aged 3 months were randomly divided into seven groups: control (olive oil treated) BPA-treated (dose 5, 50,100 μg/100gmBW) and Vitamin E intervention group (dose 5, 50, 100 μg/100gmBW BPA+ Vitamin E dose 4 mg/100gmBW). Animals were sacrificed 3 months later, and blood and tissue samples were collected. Apoptotic changes were analyzed in epididymal spermatozoa and testis tissue by binding of annexin V apoptotic biomarker. A significant decline in the weight of testis, testosterone level, and sperm count was observed. Histopathological and apoptotic changes were observed in testis tissue. In epididymal sperms, the early apoptotic cells were observed by staining of annexin V-conjugated FITC and PI green fluorescence in spermatozoa head which indicated the damage of membrane and late apoptotic cells. These changes reduced significantly in Vitamin E-treated groups though were not found to be comparable to control animals. All these changes were attributed to disrupted spermatogenesis that would interfere with sperm formation. Thus, the study infers that BPA affects the apoptosis process in the testis and epididymal sperm that would interfere with its function and contribute to infertility, whereas Vitamin E-supplemented dose has a protective effect towards these changes, indicating its role in improving male fertility.

  3. Use of tracheal auscultation for the assessment of bronchial responsiveness in asthmatic children.

    PubMed Central

    Sprikkelman, A. B.; Grol, M. H.; Lourens, M. S.; Gerritsen, J.; Heymans, H. S.; van Aalderen, W. M.

    1996-01-01

    BACKGROUND: It can be difficult to assess bronchial responsiveness in children because of their inability to perform spirometric tests reliably. In bronchial challenges lung sounds could be used to detect the required 20% fall in the forced expiratory volume in one second (FEV1). A study was undertaken to determine whether a change in lung sounds corresponded with a 20% fall in FEV1 after methacholine challenge, and whether the occurrence of wheeze was the most important change. METHODS: Fifteen children with asthma (eight boys) of mean age 10.8 years (range 8-15) were studied. All had normal chest auscultation before the methacholine challenge test. Lung sounds were recorded over the trachea for one minute and stored on tape. They were analysed directly and also scored blindly from the tape recording by a second investigator. Wheeze, cough, increase in respiratory rate, and prolonged expiration were assessed. RESULTS: The total cumulative methacholine dose causing a fall in FEV1 of 20% or more (PD20) was detected in 12 children by a change in lung sounds - in four by wheeze and in eight by cough, increased respiratory rate, and/or prolonged expiration. In two subjects altered lung sounds were detectable one dose step before PD20 was reached. In three cases in whom no fall in FEV1 occurred, no change in lung sounds could be detected at the highest methacholine dose. CONCLUSION: Changes in lung sounds correspond well with a 20% fall in FEV1 after methacholine challenge. Wheeze is an insensitive indicator for assessing bronchial responsiveness. Cough, increase in respiratory rate, and prolonged expiration occurs more frequently. PMID:8779140

  4. Drosophila melanogaster Natural Variation Affects Growth Dynamics of Infecting Listeria monocytogenes

    PubMed Central

    Hotson, Alejandra Guzmán; Schneider, David S.

    2015-01-01

    We find that in a Listeria monocytogenes/Drosophila melanogaster infection model, L. monocytogenes grows according to logistic kinetics, which means we can measure both a maximal growth rate and growth plateau for the microbe. Genetic variation of the host affects both of the pathogen growth parameters, and they can vary independently. Because growth rates and ceilings both correlate with host survival, both properties could drive evolution of the host. We find that growth rates and ceilings are sensitive to the initial infectious dose in a host genotype–dependent manner, implying that experimental results differ as we change the original challenge dose within a single strain of host. PMID:26438294

  5. Real-time tracking of respiratory-induced tumor motion by dose-rate regulation

    NASA Astrophysics Data System (ADS)

    Han-Oh, Yeonju Sarah

    We have developed a novel real-time tumor-tracking technology, called Dose-Rate-Regulated Tracking (DRRT), to compensate for tumor motion caused by breathing. Unlike other previously proposed tumor-tracking methods, this new method uses a preprogrammed dynamic multileaf collimator (MLC) sequence in combination with real-time dose-rate control. This new scheme circumvents the technical challenge in MLC-based tumor tracking, that is to control the MLC motion in real time, based on real-time detected tumor motion. The preprogrammed MLC sequence describes the movement of the tumor, as a function of breathing phase, amplitude, or tidal volume. The irregularity of tumor motion during treatment is handled by real-time regulation of the dose rate, which effectively speeds up or slows down the delivery of radiation as needed. This method is based on the fact that all of the parameters in dynamic radiation delivery, including MLC motion, are enslaved to the cumulative dose, which, in turn, can be accelerated or decelerated by varying the dose rate. Because commercially available MLC systems do not allow the MLC delivery sequence to be modified in real time based on the patient's breathing signal, previously proposed tumor-tracking techniques using a MLC cannot be readily implemented in the clinic today. By using a preprogrammed MLC sequence to handle the required motion, the task for real-time control is greatly simplified. We have developed and tested the pre- programmed MLC sequence and the dose-rate regulation algorithm using lung-cancer patients breathing signals. It has been shown that DRRT can track the tumor with an accuracy of less than 2 mm for a latency of the DRRT system of less than 0.35 s. We also have evaluated the usefulness of guided breathing for DRRT. Since DRRT by its very nature can compensate for breathing-period changes, guided breathing was shown to be unnecessary for real-time tracking when using DRRT. Finally, DRRT uses the existing dose-rate control system that is provided for current linear accelerators. Therefore, DRRT can be achieved with minimal modification of existing technology, and this can shorten substantially the time necessary to establish DRRT in clinical practice.

  6. Calibration factors for the SNOOPY NP-100 neutron dosimeter

    NASA Astrophysics Data System (ADS)

    Moscu, D. F.; McNeill, F. E.; Chase, J.

    2007-10-01

    Within CANDU nuclear power facilities, only a small fraction of workers are exposed to neutron radiation. For these individuals, roughly 4.5% of the total radiation equivalent dose is the result of exposure to neutrons. When this figure is considered across all workers receiving external exposure of any kind, only 0.25% of the total radiation equivalent dose is the result of exposure to neutrons. At many facilities, the NP-100 neutron dosimeter, manufactured by Canberra Industries Incorporated, is employed in both direct and indirect dosimetry methods. Also known as "SNOOPY", these detectors undergo calibration, which results in a calibration factor relating the neutron count rate to the ambient dose equivalent rate, using a standard Am-Be neutron source. Using measurements presented in a technical note, readings from the dosimeter for six different neutron fields in six source-detector orientations were used, to determine a calibration factor for each of these sources. The calibration factor depends on the neutron energy spectrum and the radiation weighting factor to link neutron fluence to equivalent dose. Although the neutron energy spectra measured in the CANDU workplace are quite different than that of the Am-Be calibration source, the calibration factor remains constant - within acceptable limits - regardless of the neutron source used in the calibration; for the specified calibration orientation and current radiation weighting factors. However, changing the value of the radiation weighting factors would result in changes to the calibration factor. In the event of changes to the radiation weighting factors, it will be necessary to assess whether a change to the calibration process or resulting calibration factor is warranted.

  7. Time- and dose-dependent changes in neuronal activity produced by X radiation in brain slices.

    PubMed

    Pellmar, T C; Schauer, D A; Zeman, G H

    1990-05-01

    A new method of exposing tissues to X rays in a lead Faraday cage has made it possible to examine directly radiation damage to isolated neuronal tissue. Thin slices of hippocampus from brains of euthanized guinea pigs were exposed to 17.4 ke V X radiation. Electrophysiological recordings were made before, during, and after exposure to doses between 5 and 65 Gy at a dose rate of 1.54 Gy/min. Following exposure to doses of 40 Gy and greater, the synaptic potential was enhanced, reaching a steady level soon after exposure. The ability of the synaptic potential to generate a spike was reduced and damage progressed after termination of the radiation exposure. Recovery was not observed following termination of exposure. These results demonstrate that an isolated neuronal network can show complex changes in electrophysiological properties following moderate doses of ionizing radiation. An investigation of radiation damage directly to neurons in vitro will contribute to the understanding of the underlying mechanisms of radiation-induced nervous system dysfunction.

  8. SU-F-T-584: Investigating Correction Methods for Ion Recombination Effects in OCTAVIUS 1000 SRS Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knill, C; Wayne State University School of Medicine, Detroit, MI; Snyder, M

    Purpose: PTW’s Octavius 1000 SRS array performs IMRT QA measurements with liquid filled ionization chambers (LICs). Collection efficiencies of LICs have been shown to change during IMRT delivery as a function of LINAC pulse frequency and pulse dose, which affects QA results. In this study, two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: For the first correction, Matlab software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information ismore » converted to collection efficiency and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction, MU/min in daily 1000 SRS calibration was chosen to match average MU/min of the VMAT plan. Usefulness of derived corrections were evaluated using 6MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam equipped with an HD- MLC. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: After complex Matlab corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex Matlab corrections. Conclusion: Ion recombination effects can potentially be clinically significant for OCTAVIUS 1000 SRS measurements, especially for higher pulse dose unflattened beams when using tighter gamma tolerances. Matching daily 1000 SRS calibration MU/min to average planned MU/min is a simple correction that greatly reduces ion recombination effects, improving measurements accuracy and gamma pass rates. This work was supported by PTW.« less

  9. Effect of pill burden on dosing preferences, willingness to pay, and likely adherence among patients with type 2 diabetes

    PubMed Central

    Hauber, A Brett; Han, Steven; Yang, Jui-Chen; Gantz, Ira; Tunceli, Kaan; Gonzalez, Juan Marcos; Brodovicz, Kimberly; Alexander, Charles M; Davies, Michael; Iglay, Kristy; Zhang, Qiaoyi; Radican, Larry

    2013-01-01

    Purpose To quantify willingness-to-pay (WTP) for reducing pill burden and dosing frequency among patients with type 2 diabetes mellitus (T2DM), and to examine the effect of dosing frequency and pill burden on likely medication adherence. Patients and methods Participants were US adults with T2DM on oral antihyperglycemic therapy. Each patient completed an online discrete-choice experiment (DCE) with eight choice questions, each including a pair of hypothetical medication profiles. Each profile was defined by reduction in average glucose (AG), daily dosing, chance of mild-to-moderate stomach problems, frequency of hypoglycemia, weight change, incremental risk of congestive heart failure (CHF), and cost. Patients were asked to rate their likely adherence to the profiles presented in each question. Choice questions were based on a predetermined experimental design. Choice data were analyzed using random-parameters logit. Likely treatment adherence was analyzed using a Heckman two-stage model. Results Of the 1,114 patients who completed the survey, 90 had lower dosing burden (<5 pills/day taken once/day or as needed) for all medications, and 1,024 had higher dosing burden (≥5 pills/day or more than once/day). Reduction in AG was valued most highly by patients. Hypoglycemia, chance of mild-to-moderate stomach problems, weight change, incremental risk of CHF, and daily dosing were less valued. Patients with higher current dosing burden had lower WTP for more convenient dosing schedules than patients with lower current dosing burden. Changes in dosing and cost impacted likely adherence. The magnitude of the impact of dosing on likely adherence was higher for patients with lower current dosing burden than for patients with higher current dosing burden. Conclusion Patients with T2DM were willing to pay for improvements in efficacy, side effects, and dosing. Patients’ WTP for more convenient dosing depended on current dosing burden, as did the effect of these attributes on likely adherence. PMID:24086104

  10. Determination of the uncertainties in radiation doses from ingestion of strontium-90

    NASA Astrophysics Data System (ADS)

    Apostoaei, Andrei Iulian

    Quantification of the uncertainties in the internal dosimetry is important because it can impact the outcome of dose reconstruction, risk assessment or epidemiological studies. This research focused on determination of the uncertainties in the dose factors from a single ingestion of 90Sr by adults, and analyzed the changes with age and the effect of gender. The uncertainties in the estimated dose factors are a factor of 6 for the bone surface, 5 for the red bone marrow, 2.5 for bladder and stomach, 2.2 for the small intestine, 2.1 for the upper large intestine and 2.7 for the lower large intestine. For the rest of the organs the uncertainty is a factor of 3. Only four parameters of the biokinetic model showed an age-dependency within the adult age group: the fractional transfers of strontium from plasma to cortical and trabecular bone, and the removal rates from the cortical and trabecular bone, respectively. When age-dependent biokinetic parameters were used, the estimated dose-factors are very close to the dose factors obtained using age-independent kinetics (within 40%). Thus, the dose factors based on age-independent parameters should suffice for most practical purposes. The dose factors and the associated uncertainties were also calculated as a function of age-at-exposure and attained age. These age dependent curves can be used for estimating doses from continuous intakes, or doses delivered over a limited portion of time. In addition to the committed dose, an expected dose is also estimated in this work. The expected dose is calculated using the dose rate weighted by the probability of surviving up to the age when the dose-rate is delivered. For exposure at young ages the expected dose and the committed dose are similar, but the committed dose decreases to zero when exposure occurs close to age 70, while the expected dose has elevated values pass age 70. No gender differences were found for bone surface, for red bone marrow, and the large intestine. The doses to the soft tissues for females are larger by 20% than the doses for males, because of the differences in the whole-body mass between males and females.

  11. [Effect of substance P on cardiac autonomic nervous function in rats].

    PubMed

    Deng, Lijun; Li, Jing; Yan, Fuping; Lu, Jie

    2009-12-01

    Forty SD rats were divided into 5 groups: control group, SP groups (5 microg/kg,10 microg/kg, 20 microg/kg) and spantide II plus SP group. An analysis of heart rate variability (HRV) was used to detect the changes of HRV parameters before and after intravenous injection of SP in order to investigate the effect of substance P on cardiac autonomic nervous function and the corresponding mechanism. (1) There were significant differences in most HRV parameters for the three different doses of SP. Mean heart period (MHP), absolute power of ultra-low frequency and high frequency band (APU, APH), total power (TPV) and ratio of power in ultra-low to high frequency band (RUH) increased, while mean heart rate (MHR) and chaos intensity (HCC) decreased during the 30 minutes. Each peak amplitude of HRV parameters went higher and showed up ahead of the upward doses of SP. (2) Significant change was seen in each of the parameters between spantide II plus SP group and high-dose SP group. These data idicate that, after intravenous injection of different doses of SP, both cardiac sympathetic nervous system activity and parasympathetic nervous system activity increase, and the function of cardiac autonomic nervous becomes instable and unbalanced. The effect of SP may be dose dependent, and it is possibly mediated by neurokinin-1(NK-1) receptor.

  12. Indirect blood pressure and heart rate measured quickly without observer bias using a semi-automatic machine (auto-manometer)--response to isometric exercise in normal healthy males and its modification by beta-adrenoceptor blockade.

    PubMed Central

    Nyberg, G

    1977-01-01

    1 In a double-blind crossover study, six volunteers performed sustained handgrip at 50% of maximal voluntary contraction before and 90 min following oral administration of 0.25 and 100 mg metoprolol tartrate, a beta1 selective adrenoceptor blocking agent. Blood pressure and heart rate were measured with the Auto-Manometer, an electronic semi-automatic device based on the principles of the London School of Hygiene and Tropical Medicine sphygmomanometer. It eliminates observer and digital bias completely, and also records heart rate at the same time as blood pressure is recorded. 2 Resting heart rate fell 15% after 25 mg, 21% after 100 mg and was unchanged after placebo. Systolic blood pressure fell 6% on both doses and was unchanged on placebo. Diastolic pressure did not change with any of the doses. 3 At 1 min of handgrip, heart rate was significantly lower after 25 and 100 mg than before drug or after placebo. There was no difference between the blood pressure levels attained before or after any of the dose levels. The rise of heart rate tended to be somewhat dampened after 100 mg only. The rise in blood pressure was unchanged after any dose compared with before. Images Figure 1 PMID:901695

  13. A model immunization programme to control Japanese encephalitis in Viet Nam.

    PubMed

    Yen, Nguyen Thu; Liu, Wei; Hanh, Hoang Duc; Chang, Na Yoon; Duong, Tran Nhu; Gibbons, Robert V; Marks, Florian; Thu, Nghiem Anh; Hong, Nguyen Minh; Park, Jin Kyung; Tuan, Pham Anh; Nisalak, Ananda; Clemens, John D; Xu, Zhi-Yi

    2015-03-01

    In Viet Nam, an inactivated, mouse brain-derived vaccine for Japanese encephalitis (JE) has been given exclusively to ≤ 5 years old children in 3 paediatric doses since 1997. However, JE incidence remained high, especially among children aged 5-9 years. We conducted a model JE immunization programme to assess the feasibility and impact of JE vaccine administered to 1-9 year(s) children in 3 standard-dose regimen: paediatric doses for children aged <3 years and adult doses for those aged ≥ 3 years. Of the targeted children, 96.2% were immunized with ≥ 2 doses of the vaccine. Compared to the national immunization programme, JE incidence rate declined sharply in districts with the model programme (11.32 to 0.87 per 100,000 in pre-versus post-vaccination period). The rate of reduction was most significant in the 5-9 years age-group. We recommend a policy change to include 5-9 years old children in the catch-up immunization campaign and administer a 4th dose to those aged 5-9 years, who had received 3 doses of the vaccine during the first 2-3 years of life.

  14. A Model Immunization Programme to Control Japanese Encephalitis in Viet Nam

    PubMed Central

    Yen, Nguyen Thu; Hanh, Hoang Duc; Chang, Na Yoon; Duong, Tran Nhu; Gibbons, Robert V.; Marks, Florian; Thu, Nghiem Anh; Hong, Nguyen Minh; Park, Jin Kyung; Tuan, Pham Anh; Nisalak, Ananda; Clemens, John D.; Xu, Zhi-yi

    2015-01-01

    ABSTRACT In Viet Nam, an inactivated, mouse brain-derived vaccine for Japanese encephalitis (JE) has been given exclusively to ≤5 years old children in 3 paediatric doses since 1997. However, JE incidence remained high, especially among children aged 5-9 years. We conducted a model JE immunization programme to assess the feasibility and impact of JE vaccine administered to 1-9 year(s) children in 3 standard-dose regimen: paediatric doses for children aged <3 years and adult doses for those aged ≥3 years. Of the targeted children, 96.2% were immunized with ≥2 doses of the vaccine. Compared to the national immunization programme, JE incidence rate declined sharply in districts with the model programme (11.32 to 0.87 per 100,000 in pre-versus post-vaccination period). The rate of reduction was most significant in the 5-9 years age-group. We recommend a policy change to include 5-9 years old children in the catch-up immunization campaign and administer a 4th dose to those aged 5-9 years, who had received 3 doses of the vaccine during the first 2-3 years of life. PMID:25995736

  15. Status of NCRP Scientific Committee 1-23 Commentary on Guidance on Radiation Dose Limits for the Lens of the Eye.

    PubMed

    Dauer, Lawrence T; Ainsbury, Elizabeth A; Dynlacht, Joseph; Hoel, David; Klein, Barbara E K; Mayer, Don; Prescott, Christina R; Thornton, Raymond H; Vano, Eliseo; Woloschak, Gayle E; Flannery, Cynthia M; Goldstein, Lee E; Hamada, Nobuyuki; Tran, Phung K; Grissom, Michael P; Blakely, Eleanor A

    2016-02-01

    Previous National Council on Radiation Protection and Measurements (NCRP) publications have addressed the issues of risk and dose limitation in radiation protection and included guidance on specific organs and the lens of the eye. NCRP decided to prepare an updated commentary intended to enhance the previous recommendations provided in earlier reports. The NCRP Scientific Committee 1-23 (SC 1-23) is charged with preparing a commentary that will evaluate recent studies on the radiation dose response for the development of cataracts and also consider the type and severity of the cataracts as well as the dose rate; provide guidance on whether existing dose limits to the lens of the eye should be changed in the United States; and suggest research needs regarding radiation effects on and dose limits to the lens of the eye. A status of the ongoing work of SC 1-23 was presented at the Annual Meeting, "Changing Regulations and Radiation Guidance: What Does the Future Hold?" The following represents a synopsis of a few main points in the current draft commentary. It is likely that several changes will be forthcoming as SC 1-23 responds to subject matter expert review and develops a final document, expected by mid 2016.

  16. Dissociation between the effects of P1, P4-diadenosine tetraphosphate (Ap4A) on renal haemodynamics and tubular function in anaesthetized rats.

    PubMed

    Jankowski, M; Angielski, S; Szczepańska-Konkel, M

    2008-03-01

    Previous studies from our laboratory have reported a marked reduction in glomerular filtration rate (GFR) and sodium reabsorption in renal proximal tubule during intravenous infusion of P(1),P(4)-diadenosine tetraphosphate (Ap(4)A) at dose of 1.0 micromol/kg + 10 nmol/kg/min (i.v., injection followed by infusion) in anaesthetized Wistar rats. In the present study, the changes of GFR and urine sodium excretion were investigated in response to systemic infusion of Ap(4)A at different doses. Ap(4)A at dose of 0.1 micromol/kg + 1.0 nmol/kg/min did not change GFR and sodium urinary excretion whereas 2-fold higher dose produced significant (3.4-fold) increase in sodium excretion without changes in GFR. Significant but transient reduction in GFR by approximately 21% was observed during infusion of Ap(4)A at dose of 0.5 micromol/kg + 5.0 nmol/kg/min. Higher doses of Ap(4)A (1.0 micromol/kg + 10 nmol/kg/min and 2.0 micromol/kg + 20 nmol/kg/min) reduction in GFR and marked natriuresis. Our results suggest that tubular sodium transport systems are more sensitive to Ap(4)A than systems involved in GFR regulation.

  17. The Effect of Low Monotonic Doses of Zearalenone on Selected Reproductive Tissues in Pre-Pubertal Female Dogs--A Review.

    PubMed

    Gajęcka, Magdalena; Zielonka, Łukasz; Gajęcki, Maciej

    2015-11-19

    The growing interest in toxic substances combined with advancements in biological sciences has shed a new light on the problem of mycotoxins contaminating feeds and foods. An interdisciplinary approach was developed by identifying dose-response relationships in key research concepts, including the low dose theory of estrogen-like compounds, hormesis, NOAEL dose, compensatory response and/or food tolerance, and effects of exposure to undesirable substances. The above considerations increased the researchers' interest in risk evaluation, namely: (i) clinical symptoms associated with long-term, daily exposure to low doses of a toxic compound; and (ii) dysfunctions at cellular or tissue level that do not produce clinical symptoms. Research advancements facilitate the extrapolation of results and promote the use of novel tools for evaluating the risk of exposure, for example exposure to zearalenone in pre-pubertal female dogs. The arguments presented in this paper suggest that low doses of zearalenone in commercial feeds stimulate metabolic processes and increase weight gains. Those processes are accompanied by lower proliferation rates in the ovaries, neoangiogenesis and vasodilation in the ovaries and the uterus, changes in the steroid hormone profile, and changes in the activity of hydroxysteroid dehydrogenases. All of the above changes result from exogenous hyperestrogenizm.

  18. [Effect of aminazine on elaboration and extinction of an instrumental alimentary reflex in puppies].

    PubMed

    Lozovskaia, R G

    1977-01-01

    The role of the adrenoreactive structures of the stem reticular formation in the elaboration and extinction of a food-procuring reflex of lever pressing was studied in 40 to 50 days old puppies. A 0.05 mg/kg dose of chlorpromazine proved more effective than a 0.5 mg/kg dose, in reducing both the rate of formation and of extiction of the reflex. The change in the course of elaboration was connected with the appearance of the phenomenon of reinforcement anticipation, which is not inherent in normal puppies of an early age. It is assumed that a 0.05 mg/kg dose diminishes the adrenergic ascending influences which prevail in normal puppies of the given age, while a 0.5 mg/kg dose exerts not only an adreno- but a cholinolytic action as well, without changing the balance between the systems or influencing the behaviour of the puppies.

  19. WE-EF-BRA-06: Feasibility of Spatially Modulated Proton Beams for Small Animal Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, E; Meyer, J

    Purpose: To investigate the feasibility of proton minibeam radiotherapy (pMBRT) for small animal research. The motivation is to explore with protons the extraordinary normal tissue sparing effects to spatially modulated beams as observed on high flux synchrotron beam lines. We hypothesized that we can design a multi-slit collimator for our proton beam line to produce planar-parallel dose profiles with high modulation in the entrance region and homogenous dose coverage in the overlap of the Bragg peaks. Methods: The high dose rate 50 MeV research proton beamline at the University of Washington was modeled using the TOol for PArticle Simulation (TOPAS)more » Monte Carlo package. A brass collimator was implemented to generate proton minibeams. The collimator consists of an array of 2 cm long slits to cover an area of 2×2 cm{sup 2}. The slit widths (0.1–1 mm), center-to-center (ctc) distances (1–3 mm) and collimator thickness (1–7 cm) were varied to evaluate the effect on dose rate, the peak-to-valley dose ratios (PVDR) and the change of penumbra and peak width (FWHM) with depth. Results: The Bragg peak was at a depth of ∼21 mm. The penumbra and FWHM remained relatively constant to a depth of about 10–15 mm. The PVDR ranged from 1.6 to 26 and the dose rate dropped exponentially with collimator thickness. A uniform dose can be achieved at depth with slightly compromised PVDRs and dose rate. Conclusion: The technical realization of pMBRT is feasible. The simulations have shown that it is possible to obtain uniform dose at depth while modulation is maintained on the entrance side. While the simulated beam widths are larger than on synchrotron generated microbeams the dosimetric advantage could avoid having to interlace two microbeams to achieve uniform dose in the target. The next steps are to build a collimator and verify the simulations experimentally.« less

  20. Assessment of cisplatin-induced kidney injury using an integrated rodent platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yafei; Brott, David; Luo, Wenli

    Current diagnosis of drug-induced kidney injury (DIKI) primarily relies on detection of elevated plasma creatinine (Cr) or blood urea nitrogen (BUN) levels; however, both are indices of overall kidney function and changes are delayed with respect to onset of nephron injury. Our aim was to investigate whether early changes in new urinary DIKI biomarkers predict plasma Cr, BUN, renal hemodynamic and kidney morphological changes associated with kidney injury following a single dose of cisplatin (CDDP) using an integrated platform in rodent. Conscious surgically prepared male Han Wistar rats were given a single intraperitoneal dose of CDDP (15 mg/kg). Glomerular filtrationmore » rate (GFR), effective renal plasma flow (ERPF), urinalysis, DIKI biomarkers, CDDP pharmacokinetics, blood pressures, heart rate, body temperature and electroencephalogram (EEG) were measured in the same vehicle- or CDDP-treated animals over 72 h. Plasma chemistry (including Cr and BUN) and renal tissues were examined at study termination. Cisplatin caused progressive reductions of GFR, ERPF, heart rate and body temperature from day 1 (0–24 h). DIKI biomarkers including alpha-glutathione S-transferase (α-GST) significantly increased as early as 6 h post-dose, which preceded significant declines of GFR and ERPF (24 h), increased plasma Cr and BUN (72 h), and associated with renal acute tubular necrosis at 72 h post-dose. The present study adds to the current understanding of CDDP action by demonstrating that early increases in urinary excretion of α-GST predict DIKI risk following acute exposure to CDDP in rats, before changes in traditional DIKI markers are evident. - Highlights: ► CDDP causes direct damage to kidneys without affecting EEG or CVS function. ► α-GST and albumin detect DIKI earlier when compared with traditional indices. ► Integrated “cardiovascular-EEG-renal” model to better understand DIKI mechanisms ► Promotes 3R's principles in drug discovery and development.« less

  1. The effects of different dosage levels of hepatitis B vaccine as booster on anti-HBs-negative children 5–15 y after primary immunization; China, 2009–2010

    PubMed Central

    Chen, Yongdi; Lv, Huakun; Gu, Hua; Cui, Fujiang; Wang, Fuzhen; Yao, Jun; Xia, Shichang; Liang, Xiaofeng

    2014-01-01

    The changes in lgG antibody levels to hepatitis B surface antigen (HBsAg) and in antibody to HBsAg (anti-HBs) seroconversion rates due to different dosages of hepatitis B vaccine (HepB) were compared in 2106 children. Children who had been previously vaccinated as infants with HepB were revaccinated at 5–15 y of age, after which the antibody titers were determined. After the first booster dose, the anti-HBs seroconversion rate (defined as an anti-HBs ≥10 mIU/ml) with 10 μg of HepB (93.6%) was significantly greater than the rate with 5 µg of HepB (90.3%) (P < 0.05); the anti-HBs seroconversion rate in 10–15-y-old boys vaccinated with 10 μg of HepB (90.9%) was significantly greater than the rate with 5 µg of HepB (84.3%) (P < 0.05). The anti-HBs seroconversion rates after the third booster dose with 5 or 10 μg of HepB were greater than those after the first booster dose (99.6% and 99.7%, vs. 90.3% and 93.6%, P < 0.05); as was the corresponding GMTs (658 ± 4 mIU/ml and 2599 ± 3 mIU/ml, vs. 255 ± 11 mIU/ml and 877 ± 11 mIU/ml [P < 0.05]). The immunization effects of booster vaccination with 3 doses of HepB with 5 or 10 µg are effective; a single booster dose with 10 µg of HepB for 10–15-y-old boys and with 5 or 10 µg of HepB for 5–9 y old boys and for 5–15-y-old girls are effective in generating protective antibody against HBV; however, for anti-HBs-negative children after a single dose of booster, 3 doses are needed. PMID:24192508

  2. The effects of different dosage levels of hepatitis B vaccine as booster on anti-HBs-negative children 5-15 y after primary immunization; China, 2009-2010.

    PubMed

    Chen, Yongdi; Lv, Huakun; Gu, Hua; Cui, Fujiang; Wang, Fuzhen; Yao, Jun; Xia, Shichang; Liang, Xiaofeng

    2014-01-01

    The changes in lgG antibody levels to hepatitis B surface antigen (HBsAg) and in antibody to HBsAg (anti-HBs) seroconversion rates due to different dosages of hepatitis B vaccine (HepB) were compared in 2106 children. Children who had been previously vaccinated as infants with HepB were revaccinated at 5-15 y of age, after which the antibody titers were determined. After the first booster dose, the anti-HBs seroconversion rate (defined as an anti-HBs ≥10 mIU/ml) with 10 μg of HepB (93.6%) was significantly greater than the rate with 5 µg of HepB (90.3%) (P<0.05); the anti-HBs seroconversion rate in 10-15-y-old boys vaccinated with 10 μg of HepB (90.9%) was significantly greater than the rate with 5 µg of HepB (84.3%) (P<0.05). The anti-HBs seroconversion rates after the third booster dose with 5 or 10 μg of HepB were greater than those after the first booster dose (99.6% and 99.7%, vs. 90.3% and 93.6%, P<0.05); as was the corresponding GMTs (658 ± 4 mIU/ml and 2599 ± 3 mIU/ml, vs. 255 ± 11 mIU/ml and 877 ± 11 mIU/ml [P<0.05]). The immunization effects of booster vaccination with 3 doses of HepB with 5 or 10 µg are effective; a single booster dose with 10 µg of HepB for 10-15-y-old boys and with 5 or 10 µg of HepB for 5-9 y old boys and for 5-15-y-old girls are effective in generating protective antibody against HBV; however, for anti-HBs-negative children after a single dose of booster, 3 doses are needed.

  3. “Resting” CBF in the Epileptic Baboon: Correlation with Ketamine Dose and Interictal Epileptic Discharges

    PubMed Central

    Szabó, C. Ákos; Narayana, Shalini; Franklin, Crystal; Knape, Koyle D.; Davis, M. Duff; Fox, Peter T.; Leland, M. Michelle; Williams, Jeff T.

    2011-01-01

    Background Photosensitive epileptic (SZ) baboons demonstrate different cerebral blood flow (CBF) activation patterns from asymptomatic controls (CTL) during intermittent light stimulation (ILS). This study compares “resting” CBF between PS and CTL animals, and CBF correlations with ketamine dose and interictal epileptic discharges (IEDs) between PS and CTL animals. Methods Continuous intravenous ketamine was administered to eight PS and eight CTL baboons (matched for gender and weight), and maintained at subanesthetic doses (4.8–14.6 mg/kg/hr). Three resting H215O-PET studies were attempted in each animal (CTI/Siemens HR+ scanner). Images were acquired in 3D mode (63 contiguous slices, 2.4 mm thickness). PET images were co-registered with MRI images (3T Siemens Trio, T1-weighted 3D Turboflash sequence, TE/TR/TI = 3.04/2100/785 msec, flip angle=13 degrees). EEG was used to monitor depth of sedation and for quantification of IED rates. Regional CBF was compared between PS and CTL groups and correlations were analyzed for ketamine dose and IED rates. Results When subsets of animals of either group, receiving similar doses of ketamine were compared, PS animals demonstrated relative CBF increases in the occipital lobes and decreases in the frontal lobes. Correlation analyses with ketamine dose confirmed the frontal and occipital lobe changes in the PS animals. The negative correlations of CBF with ketamine dose and IED rate overlapped frontally. While frontal lobe CBF was also negatively correlated with IED rate, positive correlations were found in the parietal lobe. Conclusions “Resting” CBF differs between PS and CTL baboons. Correlation analyses of CBF and ketamine dose reveal that occipital lobe CBF increases and frontal lobe in PS animals are driven by ketamine. While frontal lobe CBF decreases may be related to ketamine’s propensity to activate IEDs, positive CBF correlations with IED rate suggest involvement of the parietal lobes in their generation. PMID:18801644

  4. A quantitative assessment of volumetric and anatomic changes of the parotid gland during intensity-modulated radiotherapy for head and neck cancer using serial computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ajani, Abdallah A.; Qureshi, Muhammad M.; Kovalchuk, Nataliya

    To evaluate the change in volume and movement of the parotid gland measured by serial contrast-enhanced computed tomography scans in patients with head and neck cancer treated with parotid-sparing intensity-modulated radiotherapy (IMRT). A prospective study was performed on 13 patients with head and neck cancer undergoing dose-painted IMRT to 69.96 Gy in 33 fractions. Serial computed tomography scans were performed at baseline, weeks 2, 4, and 6 of radiotherapy (RT), and at 6 weeks post-RT. The parotid volume was contoured at each scan, and the movement of the medial and lateral borders was measured. The patient's body weight was recordedmore » at each corresponding week during RT. Regression analyses were performed to ascertain the rate of change during treatment as a percent change per fraction in parotid volume and distance relative to baseline. The mean parotid volume decreased by 37.3% from baseline to week 6 of RT. The overall rate of change in parotid volume during RT was−1.30% per fraction (−1.67% and−0.91% per fraction in≥31 Gy and<31 Gy mean planned parotid dose groups, respectively, p = 0.0004). The movement of parotid borders was greater in the≥31 Gy mean parotid dose group compared with the<31 Gy group (0.22% per fraction and 0.14% per fraction for the lateral border and 0.19% per fraction and 0.06% per fraction for the medial border, respectively). The median change in body weight was−7.4% (range, 0.75% to−17.5%) during RT. A positive correlation was noted between change in body weight and parotid volume during the course of RT (Spearman correlation coefficient, r = 0.66, p<0.01). Head and neck IMRT results in a volume loss of the parotid gland, which is related to the planned parotid dose, and the patient's weight loss during RT.« less

  5. Validation of an improved helical diode array and dose reconstruction software using TG‐244 datasets and stringent dose comparison criteria

    PubMed Central

    Ahmed, Saeed; Nelms, Benjamin; Kozelka, Jakub; Zhang, Geoffrey; Moros, Eduardo

    2016-01-01

    The original helical ArcCHECK (AC) diode array and associated software for 3D measurement‐guided dose reconstruction were characterized and validated; however, recent design changes to the AC required that the subject be revisited. The most important AC change starting in 2014 was a significant reduction in the overresponse of diodes to scattered radiation outside of the direct beam, accomplished by reducing the amount of high‐Z materials adjacent to the diodes. This change improved the diode measurement accuracy, but in the process invalidated the dose reconstruction models that were assembled based on measured data acquired with the older version of the AC. A correction mechanism was introduced in the reconstruction software (3DVH) to accommodate this and potential future design changes without requiring updating model parameters. For each permutation of AC serial number and beam model, the user can define in 3DVH a single correction factor which will be used to compensate for the difference in the out‐of‐field response between the new and original AC designs. The exact value can be determined by minimizing the dose‐difference with an ionization chamber or another independent dosimeter. A single value of 1.17, corresponding to the maximum measured out‐of‐field response difference between the new and old AC, provided satisfactory results for all studied energies (6X, 15X, and flattening filter‐free 10XFFF). A library of standard cases recommended by the AAPM TG‐244 Report was used for reconstructed dose verification. The overall difference between reconstructed dose and an ion chamber in a water‐equivalent phantom in the targets was 0.0% ± 1.4% (1 SD). The reconstructed dose on a homogeneous phantom was also compared to a biplanar diode dosimeter (Delta4) using gamma analysis with 2% (local dose‐error normalization)/2 mm/10% cutoff criteria. The mean agreement rate was 96.7% ± 3.7%. For the plans common with the previous comparison, the mean agreement rate was 98.3% ± 0.8%, essentially unchanged. We conclude that the proposed software modification adequately addresses the change in the dosimeter response. PACS number(s): 87.55Qr PMID:27929491

  6. Dose-rate effects on the radiation-induced oxidation of electric cable used in nuclear power plants

    NASA Astrophysics Data System (ADS)

    Reynolds, A. B.; Bell, R. M.; Bryson, N. M. N.; Doyle, T. E.; Hall, M. B.; Mason, L. R.; Quintric, L.; Terwilliger, P. L.

    1995-01-01

    Dose-rate effects were measured for typical ethylene propylene rubber (EPR) and crosslinked polyethylene (XLPE) electric cable used in nuclear power plants. The radiation source was the 60Co Irradiation Facility at the University of Virginia. Dose rates were varied from 5 Gy/h to 2500 Gy/h. It was found that there is little or no dose-rate effect at low doses for four of the five EPR cable products tested from 2500 Gy/h down to dose rates of 5 Gy/h but perhaps a small dose-rate effect at high doses for dose rates above 340 Gy/h. A small dose-rate exists for the fifth EPR above 340 Gy/h at all doses. A dose-rate effect exists above 40 Gy/h for two of the three XLPE cable products tested, but there is no dose-rate for these XLPE's between 40 Gy/h and 5 Gy/h. These results indicate that the dose-rate effects observed are due to oxygen diffusion effects during heterogeneous aging and suggest that there is no dose-rate effect for either EPR or XLPE during homogeneous aging.

  7. Typical doses and dose rates in studies pertinent to radiation risk inference at low doses and low dose rates

    PubMed Central

    Rühm, Werner; Azizova, Tamara; Bouffler, Simon; Cullings, Harry M; Grosche, Bernd; Little, Mark P; Shore, Roy S; Walsh, Linda; Woloschak, Gayle E

    2018-01-01

    Abstract In order to quantify radiation risks at exposure scenarios relevant for radiation protection, often extrapolation of data obtained at high doses and high dose rates down to low doses and low dose rates is needed. Task Group TG91 on ‘Radiation Risk Inference at Low-dose and Low-dose Rate Exposure for Radiological Protection Purposes’ of the International Commission on Radiological Protection is currently reviewing the relevant cellular, animal and human studies that could be used for that purpose. This paper provides an overview of dose rates and doses typically used or present in those studies, and compares them with doses and dose rates typical of those received by the A-bomb survivors in Japan. PMID:29432579

  8. Simple dynamic electromagnetic radiation detector

    NASA Technical Reports Server (NTRS)

    Been, J. F.

    1972-01-01

    Detector monitors gamma dose rate at particular position in a radiation facility where a mixed neutron-gamma environment exists, thus determining reactor power level changes. Device also maps gamma intensity profile across a neutron-gamma beam.

  9. Study on DNA Damage Induced by Neon Beam Irradiation in Saccharomyces Cerevisiae

    NASA Astrophysics Data System (ADS)

    Lu, Dong; Li, Wenjian; Wu, Xin; Wang, Jufang; Ma, Shuang; Liu, Qingfang; He, Jinyu; Jing, Xigang; Ding, Nan; Dai, Zhongying; Zhou, Jianping

    2010-12-01

    Yeast strain Saccharomyces cerevisiae was irradiated with different doses of 85 MeV/u 20Ne10+ to investigate DNA damage induced by heavy ion beam in eukaryotic microorganism. The survival rate, DNA double strand breaks (DSBs) and DNA polymorphic were tested after irradiation. The results showed that there were substantial differences in DNA between the control and irradiated samples. At the dose of 40 Gy, the yeast cell survival rate approached 50%, DNA double-strand breaks were barely detectable, and significant DNA polymorphism was observed. The alcohol dehydrogenase II gene was amplified and sequenced. It was observed that base changes in the mutant were mainly transversions of T→G and T→C. It can be concluded that heavy ion beam irradiation can lead to change in single gene and may be an effective way to induce mutation.

  10. SU-E-T-315: The Change of Optically Stimulated Luminescent Dosimeters (OSLDs) Sensitivity by Accumulated Dose and High Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, S; Jung, H; Kim, M

    2014-06-01

    Purpose: The objective of this study is to evaluate radiation sensitivity of optical stimulated luminance dosimeters (OSLDs) by accumulated dose and high dose. Methods: This study was carried out in Co-60 unit (Theratron 780, AECL, and Canada) and used InLight MicroStar reader (Landauer, Inc., Glenwood, IL) for reading. We annealed for 30 min using optical annealing system which contained fluorescent lamps (Osram lumilux, 24 W, 280 ∼780 nm). To evaluate change of OSLDs sensitivity by repeated irradiation, the dosimeters were repeatedly irradiated with 1 Gy. And whenever a repeated irradiation, we evaluated OSLDs sensitivity. To evaluate OSLDs sensitivity after accumulatedmore » dose with 5 Gy, We irradiated dose accumulatively (from 1 Gy to 5 Gy) without annealing. And OSLDs was also irradiated with 15, 20, 30 Gy to certify change of OSLDs sensitivity after high dose irradiation. After annealing them, they were irradiated with 1Gy, repeatedly. Results: The OSLDs sensitivity increased up to 3% during irradiating seven times and decreased continuously above 8 times. That dropped by about 0.35 Gy per an irradiation. Finally, after 30 times irradiation, OSLDs sensitivity decreased by about 7%. For accumulated dose from 1 Gy to 5 Gy, OSLDs sensitivity about 1 Gy increased until 4.4% after second times accumulated dose compared with before that. OSLDs sensitivity about 1 Gy decreased by 1.6% in five times irradiation. When OSLDs were irradiated ten times with 1Gy after irradiating high dose (10, 15, 20 Gy), OSLDs sensitivity decreased until 6%, 9%, 12% compared with it before high dose irradiation, respectively. Conclusion: This study certified OSLDs sensitivity by accumulated dose and high dose. When irradiated with 1Gy, repeatedly, OSLDs sensitivity decreased linearly and the reduction rate of OSLDs sensitivity after high dose irradiation had dependence on irradiated dose.« less

  11. Space-type radiation induces multimodal responses in the mouse gut microbiome and metabolome.

    PubMed

    Casero, David; Gill, Kirandeep; Sridharan, Vijayalakshmi; Koturbash, Igor; Nelson, Gregory; Hauer-Jensen, Martin; Boerma, Marjan; Braun, Jonathan; Cheema, Amrita K

    2017-08-18

    Space travel is associated with continuous low dose rate exposure to high linear energy transfer (LET) radiation. Pathophysiological manifestations after low dose radiation exposure are strongly influenced by non-cytocidal radiation effects, including changes in the microbiome and host gene expression. Although the importance of the gut microbiome in the maintenance of human health is well established, little is known about the role of radiation in altering the microbiome during deep-space travel. Using a mouse model for exposure to high LET radiation, we observed substantial changes in the composition and functional potential of the gut microbiome. These were accompanied by changes in the abundance of multiple metabolites, which were related to the enzymatic activity of the predicted metagenome by means of metabolic network modeling. There was a complex dynamic in microbial and metabolic composition at different radiation doses, suggestive of transient, dose-dependent interactions between microbial ecology and signals from the host's cellular damage repair processes. The observed radiation-induced changes in microbiota diversity and composition were analyzed at the functional level. A constitutive change in activity was found for several pathways dominated by microbiome-specific enzymatic reactions like carbohydrate digestion and absorption and lipopolysaccharide biosynthesis, while the activity in other radiation-responsive pathways like phosphatidylinositol signaling could be linked to dose-dependent changes in the abundance of specific taxa. The implication of microbiome-mediated pathophysiology after low dose ionizing radiation may be an unappreciated biologic hazard of space travel and deserves experimental validation. This study provides a conceptual and analytical basis of further investigations to increase our understanding of the chronic effects of space radiation on human health, and points to potential new targets for intervention in adverse radiation effects.

  12. Influence of form structure on the anesthesia preoperative evaluation.

    PubMed

    Marco, Alan P; Buchman, Debra; Lancz, Colleen

    2003-09-01

    To determine the impact of changes in form design on the capture of administrative and clinical data elements. Randomized retrospective chart review. Academic health center. Patients undergoing surgical procedures in the operating rooms at Medical College Hospital. The principal intervention was the implementation of a newly designed anesthesiology preoperative evaluation form with the intent to improve data capture. Charts were reviewed for the presence or absence of the following indicators: Addressograph Stamp, Proposed Surgery, Current Medications, Medication Doses/Frequency, Allergies, ASA Physical Status, Anesthesia Plan, Attending Note, and fasting (NPO) Status. Completion of Proposed Surgery and ASA Physical Status was lower for the structured form. Completion of Attending Notes was higher with the new form. Medication Doses were more often completed, but they remained below desired levels on the new form. Design of a form can have a significant impact on the completion rate of form elements. Visual cues such as a labeled space for medication doses may improve the completion of these elements. Design layout can also have an influence on completion. In this case, changes to the layout may have impeded the completion rate for ASA Physical Status.

  13. SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J; Molecular Imaging Program at Stanford, Stanford, CA; Bio-X Program, Stanford, CA

    2015-06-15

    Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/minmore » was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization.« less

  14. Dose rate mapping of VMAT treatments

    NASA Astrophysics Data System (ADS)

    Podesta, Mark; Antoniu Popescu, I.; Verhaegen, Frank

    2016-06-01

    Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min-1 and 12 Gy min-1 but lower dose rates have an observable sparing effect on tissues and a differential effect between tissues. In intensity-modulated radiotherapy such as volumetric modulated arc therapy (VMAT) the dose can be delivered with a wide range of dose rates. In this work we developed a method based on time-resolved Monte Carlo simulations to quantify the dose rate frequency distribution for clinical VMAT treatments for three cancer sites, head and neck, lung, and pelvis within both planning target volumes (PTV) and normal tissues. The results show a wide range of dose rates are used to deliver dose in VMAT and up to 75% of the PTV can have its dose delivered with dose rates  <1 Gy min-1. Pelvic plans on average have a lower mean dose rate within the PTV than lung or head and neck plans but a comparable mean dose rate within the organs at risk. Two VMAT plans that fulfil the same dose objectives and constraints may be delivered with different dose rate distributions, particularly when comparing single arcs to multiple arc plans. It is concluded that for dynamic plans, the dose rate range used varies to a larger degree than previously assumed. The effect of the dose rate range in VMAT on clinical outcome is unknown.

  15. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bawazeer, O; Deb, P; Sarasanandarajah, S

    2016-06-15

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest ofmore » the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.« less

  16. Study of variations in structural, optical parameters and bulk etch rate of CR-39 polymer due to electron irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahoo, G. S.; Joshi, D. S.; Tripathy, S. P., E-mail: sam.tripathy@gmail.com, E-mail: tripathy@barc.gov.in

    2016-07-14

    In this work, electron induced modifications on the bulk etch rate, structural and optical parameters of CR-39 polymer were studied using gravimetric, FTIR (Fourier Transform Infrared) and UV–vis (Ultraviolet–Visible) techniques, respectively. CR-39 samples were irradiated with 10 MeV electron beam for different durations to have the absorbed doses of 1, 10, 550, 5500, 16 500, and 55 000 kGy. From the FTIR analysis, the peak intensities at different bands were found to be changing with electron dose. A few peaks were observed to shift at high electron doses. From the UV-vis analysis, the optical band gaps for both direct and indirect transitions weremore » found to be decreasing with the increase in electron dose whereas the opacity, number of carbon atoms in conjugation length, and the number of carbon atoms per cluster were found to be increasing. The bulk etch rate was observed to be increasing with the electron dose. The primary objective of this investigation was to study the response of CR-39 to high electron doses and to determine a suitable pre-irradiation condition. The results indicated that, the CR-39 pre-irradiated with electrons can have better sensitivity and thus can be potentially applied for neutron dosimetry.« less

  17. The impact of variation in scaling factors on the estimation of ...

    EPA Pesticide Factsheets

    Many physiologically based pharmacokinetic (PBPK) models include values for metabolic rate parameters extrapolated from in vitro metabolism studies using scaling factors such as mg of microsomal protein per gram of liver (MPPGL) and liver mass (FVL). Variation in scaling factor values impacts metabolic rate parameter estimates (Vmax) and hence estimates of internal dose used in dose response analysis. The impacts of adult human variation in MPPGL and FVL on estimates of internal dose were assessed using a human PBPK model for BDCM for several internal dose metrics for two exposure scenarios (single 0.25 liter drink of water or 10 minute shower) under plausible (5 micrograms/L) and high level (20 micrograms/L) water concentrations. For both concentrations, all internal dose metrics were changed less than 5% for the showering scenario (combined inhalation and dermal exposure). In contrast, a 27-fold variation in area under the curve for BDCM in venous blood was observed at both oral exposure concentrations, whereas total amount of BDCM metabolized in liver was relatively unchanged. This analysis demonstrates that variability in the scaling factors used for in vitro to in vivo extrapolation (IVIVE) for metabolic rate parameters can have a significant route-dependent impact on estimates of internal dose under environmentally relevant exposure scenarios. This indicates the need to evaluate both uncertainty and variability for scaling factors used for IVIVE. Sca

  18. Probability Distribution of Dose and Dose-Rate Effectiveness Factor for use in Estimating Risks of Solid Cancers From Exposure to Low-Let Radiation.

    PubMed

    Kocher, David C; Apostoaei, A Iulian; Hoffman, F Owen; Trabalka, John R

    2018-06-01

    This paper presents an analysis to develop a subjective state-of-knowledge probability distribution of a dose and dose-rate effectiveness factor for use in estimating risks of solid cancers from exposure to low linear energy transfer radiation (photons or electrons) whenever linear dose responses from acute and chronic exposure are assumed. A dose and dose-rate effectiveness factor represents an assumption that the risk of a solid cancer per Gy at low acute doses or low dose rates of low linear energy transfer radiation, RL, differs from the risk per Gy at higher acute doses, RH; RL is estimated as RH divided by a dose and dose-rate effectiveness factor, where RH is estimated from analyses of dose responses in Japanese atomic-bomb survivors. A probability distribution to represent uncertainty in a dose and dose-rate effectiveness factor for solid cancers was developed from analyses of epidemiologic data on risks of incidence or mortality from all solid cancers as a group or all cancers excluding leukemias, including (1) analyses of possible nonlinearities in dose responses in atomic-bomb survivors, which give estimates of a low-dose effectiveness factor, and (2) comparisons of risks in radiation workers or members of the public from chronic exposure to low linear energy transfer radiation at low dose rates with risks in atomic-bomb survivors, which give estimates of a dose-rate effectiveness factor. Probability distributions of uncertain low-dose effectiveness factors and dose-rate effectiveness factors for solid cancer incidence and mortality were combined using assumptions about the relative weight that should be assigned to each estimate to represent its relevance to estimation of a dose and dose-rate effectiveness factor. The probability distribution of a dose and dose-rate effectiveness factor for solid cancers developed in this study has a median (50th percentile) and 90% subjective confidence interval of 1.3 (0.47, 3.6). The harmonic mean is 1.1, which implies that the arithmetic mean of an uncertain estimate of the risk of a solid cancer per Gy at low acute doses or low dose rates of low linear energy transfer radiation is only about 10% less than the mean risk per Gy at higher acute doses. Data were also evaluated to define a low acute dose or low dose rate of low linear energy transfer radiation, i.e., a dose or dose rate below which a dose and dose-rate effectiveness factor should be applied in estimating risks of solid cancers.

  19. Multiscale analysis of the radiooxidative degradation of EVA/EPDM composites. ATH filler and dose rate effect

    NASA Astrophysics Data System (ADS)

    Sidi, Ahmedou; Colombani, Juliette; Larché, Jean-François; Rivaton, Agnès

    2018-01-01

    This study is focused on the radiooxidative degradation of polymeric insulation of electric cables used in Nuclear Power Plants (NPPs). In order to investigate the degradation mechanisms of the insulation, model composites with ATH (Aluminium TriHydrate) filler and blends (without filler) based on a cross-linked mixture of EVA (Ethylene Vinyl Acetate) and EPDM (Ethylene Propylene Diene Monomer) were submitted to gamma-rays. In normal operating conditions of a NPP, the dose rate which electric cables are exposed to is around 0.1 Gy h-1. In this work, artificial accelerated ageing test process has been applied at a relatively low dose rate of 7 Gy h-1. Gamma-irradiations at higher dose rates typically used to accelerate the ageing, in the range 0.2-1 kGy h-1, were also carried out. The first part of the study is focused on irradiations performed at relatively low dose rate and is devoted to the highlighting of the radiooxidative degradation mechanisms of EVA/EPDM blend with and without ATH filler. Correlations between the evolutions of the chemical, morphological and mechanical/electrical properties of the materials occurring after the ageing process are presented. It is shown that the degradation process is governed by radical oxidation mechanism involving chain scissions leading to the formation of carboxylic acids as end-groups. One of the main effects of the ATH filler is the progressive loss of the mechanical properties of the composite upon radiooxidation whereas they are maintained in the case of the unfilled sample. Despite the oxidation of the polymer, no change in the electrical properties of the blend and of the composite could be observed. The second part of the study focuses on the dose rate effect. It is shown that one of the main consequences of an increase of the dose rate from 7 Gy h-1 to 0.2-1 kGy h-1 is a reduction of the chain scission process yield by a factor of about 20. Therefore, an important and consistent finding is that there are some limits that must not be exceeded in terms of dose rate to ensure a global satisfactorily representativeness of the accelerated ageing process.

  20. Assessment of background gamma radiation levels using airborne gamma ray spectrometer data over uranium deposits, Cuddapah Basin, India - A comparative study of dose rates estimated by AGRS and PGRS.

    PubMed

    Srinivas, D; Ramesh Babu, V; Patra, I; Tripathi, Shailesh; Ramayya, M S; Chaturvedi, A K

    2017-02-01

    The Atomic Minerals Directorate for Exploration and Research (AMD) has conducted high-resolution airborne gamma ray spectrometer (AGRS), magnetometer and time domain electromagnetic (TDEM) surveys for uranium exploration, along the northern margins of Cuddapah Basin. The survey area includes well known uranium deposits such as Lambapur-Peddagattu, Chitrial and Koppunuru. The AGRS data collected for uranium exploration is utilised for estimating the average absorbed rates in air due to radio-elemental (potassium in %, uranium and thorium in ppm) distribution over these known deposit areas. Further, portable gamma ray spectrometer (PGRS) was used to acquire data over two nearby locations one from Lambapur deposit, and the other from known anomalous zone and subsequently average gamma dose rates were estimated. Representative in-situ rock samples were also collected from these two areas and subjected to radio-elemental concentration analysis by gamma ray spectrometer (GRS) in the laboratory and then dose rates were estimated. Analyses of these three sets of results complement one another, thereby providing a comprehensive picture of the radiation environment over these deposits. The average absorbed area wise dose rate level is estimated to be 130 ± 47 nGy h -1 in Lambapur-Peddagattu, 186 ± 77 nGy h -1 in Chitrial and 63 ± 22 nGy h -1 in Koppunuru. The obtained average dose levels are found to be higher than the world average value of 54 nGy h -1 . The gamma absorbed dose rates in nGy h -1 were converted to annual effective dose rates in mSv y -1 as proposed by the United Nations Scientific Committee on the Effect of Atomic Radiation (UNSCEAR). The annual average effective dose rates for the entire surveyed area is 0.12 mSv y -1 , which is much lower than the recommended limit of 1 mSv y -1 by International Commission on Radiation protection (ICRP). It may be ascertained here that the present study establishes a reference data set (baseline) in these areas to assess any changes in gamma radiation levels due to mining and milling activities in future. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Grain elevator workers show work-related pulmonary function changes and dose-effect relationships with dust exposure.

    PubMed Central

    Corey, P; Hutcheon, M; Broder, I; Mintz, S

    1982-01-01

    The purpose of this study was to determine whether grain handlers underwent work-related changes in their pulmonary function and, if so, to examine the dose-effect relationships with dust exposure. The pulmonary function of grain handlers was measured at the beginning and end of work shifts over a period of one week, during which their exposure to dust was measured daily. The results showed changes indicative of a within-day obstructive change, in addition to a small restrictive defect occurring over the course of a week. Civic outside labourers who were examined as a control group showed a similar within-week obstructive change without any associated restriction of lung volume. The data on the grain handlers were also used to examine the dose-effect relationships of dust exposure, both on baseline pulmonary function and on within-day changes in these measurements. The baseline flow rates of workers who did not wear a mask were found to vary inversely with their average exposure to respirable dust. In addition, the flow rates underwent a within-day decrease that varied directly with their corresponding exposure to respirable dust and was unrelated to mask wearing. The median of the slopes for this relationship indicated that 50% of the subjects had a decrease of at least 923 ml/s in the value of their Vmax50%VC for each 1 mg/m3 increase in the concentration of respirable dust. Non-respirable dust did not have a measurable effect either on the baseline or the within-day changes in pulmonary function. The acute changes were unaffected by age, duration of employment, or extent of smoking. PMID:7138793

  2. The Role of Ammonia in the Metabolic Effects of Hydrazine.

    DTIC Science & Technology

    various experiments, various doses of hydrazine were given. The dogs given high doses developed hyperammonemia, respiratory alkalosis , coma and...The acute effects of administration of hydrazine on plasma ammonia, blood urea nitrogen, pH, pCO2, and respiratory rate were studied in dogs. In...convulsions. Relatively little change in blood urea nitrogen was found. Since brain function is adversely affected by hyperammonemia and alkalosis , it is

  3. The Cardiovascular Effect of Single Injection and Toxicologic Effects of Repetitive 2-Week Intravenous Administration of Activin A/BMP-2 Chimera in Beagle Dog.

    PubMed

    Lee, Jae Hyup; Choe, Senyon; Han, Shihuan

    2018-02-01

    This study was performed for the purpose to evaluate the effect of activin A/BMP-2 chimera (AB204) on cardiovascular system and toxicological effect in beagle dogs. When administered AB204 at the dose of 0.32 mg/kg via intravenous injection in beagle dogs, there were no changes in systolic, diastolic and mean blood pressure as well as in pulse rate, in addition that there were no differences in ORS complex, PR interval, R-R interval, QT interval and QTcV interval on the electrocardiography. Also, when administered AB204 at the doses of 0.25 and 0.5 mg/kg/day via repetitive intravenous injection for 2 weeks, it did not cause any significant changes in general symptoms, weight, food intake, ophthalmologic abnormality, urine, hematology, serum biochemistry, organ weight and autopsy values. Therefore, AB204 did not affect cardiovascular functions including blood pressure, pulse rate and ECG, when administered at the dose of ≤0.32 mg/kg via single intravenous injection in male beagle dogs. When it was administered at the dose of 0.5 mg/kg repetitive intravenous injection for 2 weeks, it did not show any toxicity.

  4. TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, B; Xu, H; Mutaf, Y

    2015-06-15

    Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speedmore » of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.« less

  5. Protein expression profile changes in human fibroblasts induced by low dose energetic protons

    NASA Astrophysics Data System (ADS)

    Zhang, Ye; Clement, Jade Q.; Gridley, Daila S.; Rodhe, Larry H.; Wu, Honglu

    2009-12-01

    Extrapolation of known radiation risks to the risks from low dose and low dose-rate exposures of human population, especially prolonged exposures of astronauts in the space radiation environment, relies in part on the mechanistic understanding of radiation induced biological consequences at the molecular level. While some genomic data at the mRNA level are available for cells or animals exposed to radiation, the data at the protein level are still lacking. Here, we studied protein expression profile changes using Panorama antibody microarray chips that contain antibodies to 224 proteins (or their phosphorylated forms) involved in cell signaling that included mostly apoptosis, cytoskeleton, cell cycle and signal transduction. Normal human fibroblasts were cultured until fully confluent and then exposed to 2 cGy of 150 MeV protons at high-dose rate. The proteins were isolated at 2 or 6 h after exposure and labeled with Cy3 for the irradiated cells and with Cy5 for the control samples before loading onto the protein microarray chips. The intensities of the protein spots were analyzed using ScanAlyze software and normalized by the summed fluorescence intensities and the housekeeping proteins. The results showed that low dose protons altered the expression of more than 10% of the proteins listed in the microarray analysis in various protein functional groups. Cell cycle (24%) related proteins were induced by protons and most of them were regulators of G1/S-transition phase. Comparison of the overall protein expression profiles, cell cycle related proteins, cytoskeleton and signal transduction protein groups showed significantly more changes induced by protons compared with other protein functional groups.

  6. Comparison of particulate matter dose and acute heart rate variability response in cyclists, pedestrians, bus and train passengers.

    PubMed

    Nyhan, Marguerite; McNabola, Aonghus; Misstear, Bruce

    2014-01-15

    Exposure to airborne particulate matter (PM) has been linked to cardiovascular morbidity and mortality. Heart rate variability (HRV) is a measure of the change in cardiac autonomic function, and consistent links between PM exposure and decreased HRV have been documented in studies. This study quantitatively assesses the acute relative variation of HRV with predicted PM dose in the lungs of commuters. Personal PM exposure, HR and HRV were monitored in 32 young healthy cyclists, pedestrians, bus and train passengers. Inhaled and lung deposited PM doses were determined using a numerical model of the human respiratory tract which accounted for varying ventilation rates between subjects and during commutes. Linear mixed models were used to examine air pollution dose and HRV response relationships in 122 commutes sampled. Elevated PM2.5 and PM10 inhaled and lung deposited doses were significantly (p<0.05) associated with decreased HRV indices. Percent declines in SDNN (standard deviation of normal RR intervals) relative to resting, due to an inter-quartile range increase in PM10 lung deposited dose were stronger in cyclists (-6.4%, 95% CI: -11.7, -1.3) and pedestrians (-5.8%, 95% CI: -11.3, -0.5), in comparison to bus (-3.2%, 95% CI: -6.4, -0.1) and train (-1.8%, -7.5, 3.8) passengers. A similar trend was observed in the case of PM2.5 lung deposited dose and results for rMSSD (the square root of the squared differences of successive normal RR intervals) followed similar trends to SDNN. Inhaled and lung deposited doses accounting for varying ventilation rates between modes, individuals and during commutes have been neglected in other studies relating PM to HRV. The findings here indicate that exercise whilst commuting has an influence on inhaled PM and PM lung deposited dose, and these were significantly associated with acute declines in HRV, especially in pedestrians and cyclists. © 2013.

  7. Assessment of monitor unit limiting strategy using volumetric modulated arc therapy for cancer of hypopharynx.

    PubMed

    Ahamed, Shabbir; Singh, Navin; Gudipudi, Deleep; Mulinti, Suneetha; Talluri, Anil; Soubhagya, Bhudevi; Sresty, Madhusudhana

    2017-03-01

    To quantify relative merit of MU deprived plans against freely optimized plans in terms of plan quality and report changes induced by progressive resolution optimizer algorithm (PRO3) to the dynamic parameters of RapidArc. Ten cases of carcinoma hypopharynx were retrospectively planned in three phases without using MU tool. Replicas of these baseline plans were reoptimized using "Intermediate dose" feature and "MU tool" to reduce MUs by 20%, 35%, and 50%. Overall quality indices for target and OAR, integral dose, dose-volume spread were assessed. All plans were appraised for changes induced in RapidArc dynamic parameters and pre-treatment quality assurance (QA). With increasing MU reduction strength (MURS), MU/Gy values reduced, for all phases with an overall range of 8.6-34.7%; mean dose rate decreased among plans of each phase, phase3 plans recorded greater reductions. MURS20% showed good trade-off between MUs and plan quality. Dose-volume spread below 5Gy was higher for baseline plans while lower between 20 and 35Gy. Integral dose was lower for MURS0%, not exceeding 1.0%, compared against restrained plans. Mean leaf aperture and control point areas increased systematically, correlated negatively with increasing MURS. Absolute delta dose rate variations were least for MURS0%. MU deprived plans exhibited GAI (>93%), better than MURS0% plans. Baseline plans are superior to MU restrained plans. However, MURS20% offers equivalent and acceptable plan quality with mileage of MUs, improved GAI for complex cases. MU tool may be adopted to tailor treatment plans using PRO3. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Microstructural characterization and density change of 304 stainless steel reflector blocks after long-term irradiation in EBR-II

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Wiezorek, J. M. K.; Garner, F. A.; Freyer, P. D.; Okita, T.; Sagisaka, M.; Isobe, Y.; Allen, T. R.

    2015-10-01

    While thin reactor structural components such as cladding and ducts do not experience significant gradients in dpa rate, gamma heating rate, temperature or stress, thick components can develop strong local variations in void swelling and irradiation creep in response to gradients in these variables. In this study we conducted microstructural investigations by transmission electron microscopy of two 52 mm thick 304-type stainless steel hex-blocks irradiated for 12 years in the EBR-II reactor with accumulated doses ranging from ∼0.4 to 33 dpa. Spatial variations in the populations of voids, precipitates, Frank loops and dislocation lines have been determined for 304 stainless steel sections exposed to different temperatures, different dpa levels and at different dpa rates, demonstrating the existence of spatial gradients in the resulting void swelling. The microstructural measurements compare very well with complementary density change measurements regarding void swelling gradients in the 304 stainless steel hex-block components. The TEM studies revealed that the original cold-worked-state microstructure of the unirradiated blocks was completely erased by irradiation, replaced by high densities of interstitial Frank loops, voids and carbide precipitates at both the lowest and highest doses. At large dose levels the amount of volumetric void swelling correlated directly with the gamma heating gradient-related temperature increase (e.g. for 28 dpa, ∼2% swelling at 418 °C and ∼2.9% swelling at 448 °C). Under approximately iso-thermal local conditions, volumetric void swelling was found to increase with dose level (e.g. ∼0.2% swelling at 0.4 dpa, ∼0.5% swelling at 4 dpa and ∼2% swelling at 28 dpa). Carbide precipitate formation levels were found to be relatively independent of both dpa level and temperature and induced a measurable densification. Void swelling was dominant at the higher dose levels and caused measurable decreases in density. Void swelling at the lowest doses was larger than might be expected based on the dpa level, an observation in agreement with earlier studies showing that the onset of void swelling is accelerated by decreasing dpa rates.

  9. Effect of processor temperature on film dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, Shiv P.; Das, Indra J., E-mail: idas@iupui.edu

    2012-07-01

    Optical density (OD) of a radiographic film plays an important role in radiation dosimetry, which depends on various parameters, including beam energy, depth, field size, film batch, dose, dose rate, air film interface, postexposure processing time, and temperature of the processor. Most of these parameters have been studied for Kodak XV and extended dose range (EDR) films used in radiation oncology. There is very limited information on processor temperature, which is investigated in this study. Multiple XV and EDR films were exposed in the reference condition (d{sub max.}, 10 Multiplication-Sign 10 cm{sup 2}, 100 cm) to a given dose. Anmore » automatic film processor (X-Omat 5000) was used for processing films. The temperature of the processor was adjusted manually with increasing temperature. At each temperature, a set of films was processed to evaluate OD at a given dose. For both films, OD is a linear function of processor temperature in the range of 29.4-40.6 Degree-Sign C (85-105 Degree-Sign F) for various dose ranges. The changes in processor temperature are directly related to the dose by a quadratic function. A simple linear equation is provided for the changes in OD vs. processor temperature, which could be used for correcting dose in radiation dosimetry when film is used.« less

  10. Defibrotide for the treatment of severe hepatic veno-occlusive disease and multiorgan failure after stem cell transplantation: a multicenter, randomized, dose-finding trial.

    PubMed

    Richardson, Paul G; Soiffer, Robert J; Antin, Joseph H; Uno, Hajime; Jin, Zhezhen; Kurtzberg, Joanne; Martin, Paul L; Steinbach, Gideon; Murray, Karen F; Vogelsang, Georgia B; Chen, Allen R; Krishnan, Amrita; Kernan, Nancy A; Avigan, David E; Spitzer, Thomas R; Shulman, Howard M; Di Salvo, Donald N; Revta, Carolyn; Warren, Diane; Momtaz, Parisa; Bradwin, Gary; Wei, L J; Iacobelli, Massimo; McDonald, George B; Guinan, Eva C

    2010-07-01

    Therapeutic options for severe hepatic veno-occlusive disease (VOD) are limited and outcomes are dismal, but early phase I/II studies have suggested promising activity and acceptable toxicity using the novel polydisperse oligonucleotide defibrotide. This randomized phase II dose-finding trial determined the efficacy of defibrotide in patients with severe VOD following hematopoietic stem cell transplantation (HSCT) and identified an appropriate dose for future trials. Adult and pediatric patients received either lower-dose (arm A: 25 mg/kg/day; n = 75) or higher-dose (arm B: 40 mg/kg/day; n = 74) i.v. defibrotide administered in divided doses every 6 hours for > or =14 days or until complete response, VOD progression, or any unacceptable toxicity occurred. Overall complete response and day +100 post-HSCT survival rates were 46% and 42%, respectively, with no significant difference between treatment arms. The incidence of treatment-related adverse events was low (8% overall; 7% in arm A, 10% in arm B); there was no significant difference in the overall rate of adverse events between treatment arms. Early stabilization or decreased bilirubin was associated with better response and day +100 survival, and decreased plasminogen activator inhibitor type 1 (PAI-1) during treatment was associated with better outcome; changes were similar in both treatment arms. Defibrotide 25 or 40 mg/kg/day also appears effective in treating severe VOD following HSCT. In the absence of any differences in activity, toxicity or changes in PAI-1 level, defibrotide 25 mg/kg/day was selected for ongoing phase III trials in VOD.

  11. Toxicity of dietary Heliotropium dolosum seed to broiler chickens.

    PubMed

    Eröksüz, Y; Eröksüz, H; Ozer, H; Canatan, H; Yaman, I; Cevik, A

    2001-12-01

    Five groups of 20 female broiler chicks were fed different levels of dehulled Heliotropium dolosum seed (w/w%; 0.0, 1.0, 3.0, 5.0 or 10.0%) from 10 to 52 d of age. In all doses the seed caused decreases in daily feed intake, weight gain, and feed efficiency, and biochemical findings, severity of pathologic changes, and mortality rate increased in a dose-dependent manner. Acute toxicity was observed in livers of chicks fed 10% seed. Other test groups had chronic changes. Livers had massive to submassive necrosis, hepatic megalocytosis, bile duct proliferation, fatty change, and periportal fibrosis. Biochemical evaluations revealed hypoalbuminemia, hypoprotienemia and increased ALP activity and billuribin. The seed of Heliotropium dolosum produced biochemical and specific pathologic changes in broiler chicks, as well as decreased food intake and feed efficiency. Higher seed levels induced more pronounced changes.

  12. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy.

    PubMed

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated.

  13. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy

    PubMed Central

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated. PMID:28539824

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yi, B; Chung, H; Mutaf, Y

    Purpose: To test a novel total body irradiation (TBI) system using conformal partial arc with patient lying on the stationary couch which is biologically equivalent to a moving couch TBI. This improves the scanning field TBI, which is previously presented. Methods: The Uniform MU Modulated arc Segments TBI or UMMS-TBI scans the treatment plane with a constant machine dose rate and a constant gantry rotation speed. A dynamic MLC pattern which moves while gantry rotates has been designed so that the treatment field moves same distance at the treatment plane per each gantry angle, while maintaining same treatment field sizemore » (34cm) at the plane. Dose across the plane varies due to the geometric differences including the distance from the source to a point of interest and the different attenuation from the slanted depth which changes the effective depth. Beam intensity is modulated to correct the dose variation across the plane by assigning the number of gantry angles inversely proportional to the uncorrected dose. Results: Measured dose and calculated dose matched within 1 % for central axis and 3% for off axis for various patient scenarios. Dose from different distance does not follow the inverse square relation as it is predicted from calculation. Dose uniformity better than 5% across 180 cm at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 200 MU/min. Conclusion: This novel technique, yet accurate but easy to implement enables TBI treatment in a small treatment room with less program development preparation than other techniques. The VMAT function of treatment delivery is not required to modulate beams. One delivery pattern can be used for different patients by changing the monitor units.« less

  15. Image perception by expert readers as a function of patient skin entrance dose levels in digital radiography

    NASA Astrophysics Data System (ADS)

    Lehnert, T.; Korkusuz, H.; Khan, F.; Vogl, T. J.; Mack, M. G.

    2008-03-01

    In this study, image quality was based on required clinical criteria, in order to investigate to what degree entrance dose could be lowered and what kind of added filtration can be used without impinging on radiologist confidence levels in diagnosing. Images were taken of extremities from a cadaver using stepwise decreasing dose levels and variation of added filtration (no filtration, aluminum, aluminum/copper) under digital projection radiography (Kodak DirectView DR7500). The starting point dose level for all body parts imaged was the current x-ray technique. Two experienced and two resident radiologists were presented the images in a blinded fashion and rated each with an image quality score from 1 to 9 indicated very satisfied and 1 as very unsatisfied indicating loss of diagnostic value. The readers were not aware of which dose level and added filtration corresponded to which image. Dose levels considered were 100%, 75%, 50% and 25% of the normal and customary x-ray techniques used for the particular body part and projection. Images were reviewed on a clinical diagnostic workstation with no time limits imposed. Readers were also able to change the image presentation by adjusting the window width and level. Without added filtration image quality mean score was rated with 6.3 (dose level 100%), 6.2 (dose level 75%), 5.3 (dose level 50%) and with 4.4 (dose level 25%). An added aluminum filtration induced an image quality mean score of 6.3 (dose level 100%), 6.0 (dose level 75%), 5.1 (dose level 50%) and of 4.2 (dose level 25%). Using aluminum/copper filtration image quality mean score was rated with 6.0 (dose level 100%), 6.1 (dose level 75%), 5.0 (dose level 50%) and with 3.8 (dose level 25%). Regardless of the added filtration a differentiation between dose levels 100% and 75% was possible in 38.9%, between dose levels 75% and 50% in 66.7%, and between dose levels 50% and 25% in 70.0% of the cases. It is possible, in the case of extremities, to lower entrance doses up to 75 % of the normal value, a reduction of 25% in dose, under simultaneous use of added aluminum or aluminum/copper filtration, without comprising the diagnostic value required.

  16. Reproducibility of CVD diamond detectors for radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Betzel, G. T.; Lansley, S. P.; McKay, D.; Meyer, J.

    2012-11-01

    Three in-house X-ray detectors based on diamond chemical vapor deposition (CVD) from the same manufactured batch of single crystal films were investigated for their reproducibility. Leakage current, priming dose, response dynamics, dose linearity, dependence on dose rate and angular dependence were used to evaluate differences between detectors. Slight differences were seen in leakage currents before (<1.5 pA) and after (<12 pA) irradiation. A priming dose of ˜7 Gy and rise and fall times of 2 s were found for all three detectors. Sensitivities differed by up to 10%. Dependence on dose rate were similar (∆=0.92-0.94). Angular dependence was minimal (97-102% avg.). Differences in detector performance appeared to be primarily due to film thickness, which can significantly change sensitivities (nC Gy-1) and applied fields (V μm-1) for detectors with small sensitive volumes. Results suggest that preselection of CVD diamond films according to thickness in addition to material quality would be required to avoid individual calibration, which is performed for commercially available natural diamond detectors.

  17. Effects of radiation on the leach rates of vitrified radioactive waste

    NASA Astrophysics Data System (ADS)

    Burns, W. G.; Hughes, A. E.; Marples, J. A. C.; Nelson, R. S.; Stoneham, A. M.

    1982-06-01

    This report reviews the possible effects of both radiation damage to the glass and of radiolysis of the leachant on the leaching behaviour of vitrified radioactive waste. It has been stimulated particularly by recent papers, which have suggested that the leach rates of glasses will be enhanced by large factors after a 'critical' dose of radiation from alpha decays. These experiments have been conducted at highly accelerated rates using ion beams. The relationship between these experiments and the situation in vitrified waste has been assessed, taking into account the fact that experiments using alpha emitters incorporated in the glass have failed to find significantly enhanced leach rates after doses about five times larger than those equivalent to this 'critical' dose. It is concluded that these differences are observed partly because the ion beam experiments are carried out at such high dose rates that some recovery effects important at lower rates do not come into play. In the case of experiments with 2 keV argon ions, surface effects other than genuine radiation damage must be taken into account. In practice, if water has penetrated the canister, vitrified waste will be irradiated in the presence of the leaching solution. Enhancements of the leach rate due to the transient effects of radiation in the solid are shown to be completely negligible. The effects of radiolysis of the leaching solution and of any air in contact with the solution have also been considered in some detail and related to recent experiments by McVay and Pederson. It is shown that these radiolysis effects will not lead to any situations requiring special precautions in practice, although changes in surface leach rate by small factors can be expected under some circumstances. Any effect of irradiation on leach rates must be seen in the context of a waste repository. Along with other studies we hold the view that the rate of loss of material will be limited by the access of water to the repository, and will therefore depend on the effective saturation solubility of the glass in the leachant, not on the leach rate as usually determined in laboratory tests. Radiation damage is not expected to change the saturation solubility by more than a factor of two or three.

  18. Biological Effects of Protracted Exposure to Ionizing Radiation: Review, Analysis, and Model Development

    DTIC Science & Technology

    1991-11-01

    dynamics, physiological changes, morphologi- cal changes, cell/tissue damage and recovery mechanisms, and existing radiobiological injury and recovery...humans and the ferret. The gut injury model (GIM) is a three-compartment hierarchial- type tissue model to simulate radiation-induced changes in the...Prodromal Symptoms Diarrhea Gastrointestinal Symptoms Dose Rate Cell Survival Intestinal Injury Fatigability Cell Damage Cell Repair Cell Proliferation

  19. Space weather effects measured in atmospheric radiation on aircraft

    NASA Astrophysics Data System (ADS)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Wieman, S. R.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, L. D.; Mertens, C. J.; Xu, X.; Wiltberger, M. J.; Wiley, S.; Teets, E.; Shea, M. A.; Smart, D. F.; Jones, J. B. L.; Crowley, G.; Azeem, S. I.; Halford, A. J.

    2016-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Since 2013 Space Environment Technologies (SET) has been conducting observations of the atmospheric radiation environment at aviation altitudes using a small fleet of six instruments. The objective of this work is to improve radiation risk management in air traffic operations. Under the auspices of the Automated Radiation Measurements for Aerospace Safety (ARMAS) and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) projects our team is making dose rate measurements on multiple aircraft flying global routes. Over 174 ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the radiation environment resulting from Galactic Cosmic Rays (GCRs), Solar Energetic Protons (SEPs), and outer radiation belt energetic electrons. The real-time radiation exposure is measured as an absorbed dose rate in silicon and then computed as an ambient dose equivalent rate for reporting dose relevant to radiative-sensitive organs and tissue in units of microsieverts per hour. ARMAS total ionizing absorbed dose is captured on the aircraft, downlinked in real-time, processed on the ground into ambient dose equivalent rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users. Dose rates from flight altitudes up to 56,700 ft. are shown for flights across the planet under a variety of space weather conditions. We discuss several space weather effects on the atmospheric radiation environment, including the levels of GCR background radiation, small SEP events, and possible EMIC wave driven energetic electrons from the outer radiation belt creating "radiation" clouds in the troposphere.

  20. Tofacitinib or Adalimumab versus Placebo for Psoriatic Arthritis.

    PubMed

    Mease, Philip; Hall, Stephen; FitzGerald, Oliver; van der Heijde, Désirée; Merola, Joseph F; Avila-Zapata, Francisco; Cieślak, Dorota; Graham, Daniela; Wang, Cunshan; Menon, Sujatha; Hendrikx, Thijs; Kanik, Keith S

    2017-10-19

    Tofacitinib is an oral Janus kinase inhibitor that is under investigation for the treatment of psoriatic arthritis. We evaluated tofacitinib in patients with active psoriatic arthritis who previously had an inadequate response to conventional synthetic disease-modifying antirheumatic drugs (DMARDs). In this 12-month, double-blind, active-controlled and placebo-controlled, phase 3 trial, we randomly assigned patients in a 2:2:2:1:1 ratio to receive one of the following regimens: tofacitinib at a 5-mg dose taken orally twice daily (107 patients), tofacitinib at a 10-mg dose taken orally twice daily (104), adalimumab at a 40-mg dose administered subcutaneously once every 2 weeks (106), placebo with a blinded switch to the 5-mg tofacitinib dose at 3 months (52), or placebo with a blinded switch to the 10-mg tofacitinib dose at 3 months (53). Placebo groups were pooled for analyses up to month 3. Primary end points were the proportion of patients who had an American College of Rheumatology 20 (ACR20) response (≥20% improvement from baseline in the number of tender and swollen joints and at least three of five other important domains) at month 3 and the change from baseline in the Health Assessment Questionnaire-Disability Index (HAQ-DI) score (scores range from 0 to 3, with higher scores indicating greater disability) at month 3. ACR20 response rates at month 3 were 50% in the 5-mg tofacitinib group and 61% in the 10-mg tofacitinib group, as compared with 33% in the placebo group (P=0.01 for the comparison of the 5-mg dose with placebo; P<0.001 for the comparison of the 10-mg dose with placebo); the rate was 52% in the adalimumab group. The mean change in the HAQ-DI score was -0.35 in the 5-mg tofacitinib group and -0.40 in the 10-mg tofacitinib group, as compared with -0.18 in the placebo group (P=0.006 for the comparison of the 5-mg dose with placebo; P<0.001 for the comparison of the 10-mg dose with placebo); the score change was -0.38 in the adalimumab group. The rate of adverse events through month 12 was 66% in the 5-mg tofacitinib group, 71% in the 10-mg tofacitinib group, 72% in the adalimumab group, 69% in the placebo group that switched to the 5-mg tofacitinib dose, and 64% in the placebo group that switched to the 10-mg tofacitinib dose. There were four cases of cancer, three serious infections, and four cases of herpes zoster in patients who received tofacitinib during the trial. The efficacy of tofacitinib was superior to that of placebo at month 3 in patients with psoriatic arthritis who had previously had an inadequate response to conventional synthetic DMARDs. Adverse events were more frequent with tofacitinib than with placebo. (Funded by Pfizer; OPAL Broaden ClinicalTrials.gov number, NCT01877668 .).

  1. Quantitative modeling of total ionizing dose reliability effects in device silicon dioxide layers

    NASA Astrophysics Data System (ADS)

    Rowsey, Nicole L.

    The electrical breakdown of oxides and oxide/semiconductor interfaces is one of the main reasons for device failure in integrated circuits, especially devices under high-stress conditions. One high-stress environment of interest is the space environment. All electronics are vulnerable to ionizing radiation; any high-energy particle that passes through an insulating layer will deposit unwanted charge there, causing shifts in device characteristics. Designing electronics for use in space can be a challenge, because much more energetic radiation exits in space than on Earth, as there is no atmosphere in space to collide with, and thereby reduce the energy of, energetic particles. Although oxide charging due to ionizing radiation creates well-known changes in device characteristics, or total ionizing dose effects, it is still poorly-understood exactly how these changes come about. There are many theories that draw upon a large body of both experimental work and, more recently, quantum-mechanical first principles calculations at the molecular level. This work uses FLOODS, a 3D object-oriented device simulator with multi-physics capability, to investigate these theories, by simulating oxide degradation in realistic device geometries, and comparing the subsequent degradation in device characteristics to experimental measurements. The charge trapping and defect-modulated transport models developed and implemented here have resulted in the first quantitative account of the enhanced low-dose-rate sensitivity effect, and are applicable in a comprehensive range of hydrogen environments. Measurements show that devices exposed to ionizing radiation at high dose rates exhibit less degradation that those exposed at low dose rates. Furthermore, the observed trend differs depending on the amount of hydrogen available before, during, and after irradiation. It is therefore important to understand and take into account the effects of dose rate and hydrogen when developing accelerated testing procedures for devices which have been exposed to various levels of hydrogen during processing and packaging, and which must be deployed in the low-dose-rate space environment. Thus, this work represents a substantial increase in the state-of-the-art, since a quantitative model has not previously been available. The success of the model is due in great part to the use of first-principles calculations of defect and hydrogen bond energies. Vanderbilt collaborators provided the results of these calculations as input to the FLOODS simulations. Using these physical insights, a sensitivity analysis in FLOODS yielded insights into key controlling parameters.

  2. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morton, Gerard C., E-mail: gerard.morton@sunnybrook.ca; Loblaw, D. Andrew; Chung, Hans

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domainmore » score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose to 10% of the urethra cutpoint for urinary health-related quality of life was 120% of the prescription dose. Conclusion: EPIC was a more sensitive tool for detecting the effects on function and bother than were the generic toxicity scales. The urethral dose had the strongest association with a deteriorating urinary quality of life.« less

  3. Determination of MLC model parameters for Monaco using commercial diode arrays.

    PubMed

    Kinsella, Paul; Shields, Laura; McCavana, Patrick; McClean, Brendan; Langan, Brian

    2016-07-08

    Multileaf collimators (MLCs) need to be characterized accurately in treatment planning systems to facilitate accurate intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). The aim of this study was to examine the use of MapCHECK 2 and ArcCHECK diode arrays for optimizing MLC parameters in Monaco X-ray voxel Monte Carlo (XVMC) dose calculation algorithm. A series of radiation test beams designed to evaluate MLC model parameters were delivered to MapCHECK 2, ArcCHECK, and EBT3 Gafchromic film for comparison. Initial comparison of the calculated and ArcCHECK-measured dose distributions revealed it was unclear how to change the MLC parameters to gain agreement. This ambiguity arose due to an insufficient sampling of the test field dose distributions and unexpected discrepancies in the open parts of some test fields. Consequently, the XVMC MLC parameters were optimized based on MapCHECK 2 measurements. Gafchromic EBT3 film was used to verify the accuracy of MapCHECK 2 measured dose distributions. It was found that adjustment of the MLC parameters from their default values resulted in improved global gamma analysis pass rates for MapCHECK 2 measurements versus calculated dose. The lowest pass rate of any MLC-modulated test beam improved from 68.5% to 93.5% with 3% and 2 mm gamma criteria. Given the close agreement of the optimized model to both MapCHECK 2 and film, the optimized model was used as a benchmark to highlight the relatively large discrepancies in some of the test field dose distributions found with ArcCHECK. Comparison between the optimized model-calculated dose and ArcCHECK-measured dose resulted in global gamma pass rates which ranged from 70.0%-97.9% for gamma criteria of 3% and 2 mm. The simple square fields yielded high pass rates. The lower gamma pass rates were attributed to the ArcCHECK overestimating the dose in-field for the rectangular test fields whose long axis was parallel to the long axis of the ArcCHECK. Considering ArcCHECK measurement issues and the lower gamma pass rates for the MLC-modulated test beams, it was concluded that MapCHECK 2 was a more suitable detector than ArcCHECK for the optimization process. © 2016 The Authors

  4. Do changes in biomarkers from space radiation reflect dose or risk?

    NASA Astrophysics Data System (ADS)

    Brooks, A.

    The space environment is made up of many different kinds of radiation so that the proper use of biomarkers is essential to estimate radiation risk. This presentation will evaluate differences between biomarkers of dose and risk and demonstrate why they should not be confused following radiation exposures in deep space. Dose is a physical quantity, while risk is a biological quantity. Many examples exist w ereh dose or changes in biomarkers of dose are inappropriately used as predictors of risk. Without information on the biology of the system, the biomarkers of dose provide little help in predicting risk in tissues or radiation exposure types where no excess risk can be demonstrated. Many of these biomarkers of dose only reflect changes in radiation dose or exposure. However, these markers are often incorrectly used to predict risk. For example, exposure of the trachea or of the deep lung to high-LET alpha particles results in similar changes in the biomarker chromosome damage in these two tissues. Such an observation would predict that the risk for cancer induction would be similar in these two tissues. It has been noted , however, that there has never been a tracheal tumor observed in rats that inhaled radon, but with the same exposure, large numbers of tumors were produced in the deep lung. The biology of the different tissues is the major determinant of the risk rather than the radiation dose. Recognition of this fact has resulted in the generation of tissue weighting factors for use in radiation protection. When tissue weighting factors are used the values derived are still called "dose". It is important to recognize that tissue specific observations have been corrected to reflect risk, and therefore should no longer be viewed as dose. The relative biological effectiveness (RBE) is also used to estimate radiation risk. The use of biomarkers to derive RBE is a difficult since it involves the use of a biological response to a standard low-LET reference radiation. Following low-LET radiation exposure, the biological response often does not increase as a linear function of dose. Thus, the RBE and the subsequent risk predicted is dependent on the dose where the two radiation types are compared. To avoid this problem the standard procedure is to use the dose and dose-rate response and compare the linear components of the two r diation exposures. Important riska comparisons are often done at very low doses, where the reference radiation may either increase or decrease as a function of dose. Since the low-LET exposure often does not produce a significant change above the background level of damage, the derived RBE factors can become very large.Studies using micronuclei as biomarkers following exposure to mono-energetic neutrons, x-rays and gamma rays delivered at very low doses (up to 0.10 Gy) demonstrated the differences in the shape of each dose-response relationship and the problems associated with the RBE. These studies show that RBE may not accurately reflect the hazards or risk associated with space radiation exposure. As additional measures of biological change are developed, it may become possible to base risk on biological change and not on changes in radiation doses. Research funded through grants # DE-FG03-99ER62787 from DOE Office of Biological and Environmental Research and RO1 CA74053-01 from NIH/NASA to Washington State University Tri-Cities.

  5. Active personal radiation monitor for lunar EVA

    NASA Astrophysics Data System (ADS)

    Straume, Tore; Borak, Tom; Braby, L. A.; Lusby, Terry; Semones, Edward J.; Vazquez, Marcelo E.

    As astronauts return to the Moon-and this time, work for extended periods-there will be a critical need for crew personnel radiation monitoring as they operate lunar rovers or otherwise perform a myriad of extravehicular activities (EVAs). Our focus is on development of a small personal radiation monitor for lunar EVA that responds to the complex radiation quality and changing dose rates on the Moon. Of particular concern are active monitoring capabilities that provide both early warning and radiation dosimetry information during solar particle events (SPEs). To accomplish this, we are developing small detectors integrated with modern high speed, low power microelectronics to measure dose-rate and dose-mean lineal energy in real time. The monitor is designed to perform over the range of dose rates and LETs expected from both GCR and SPE radiations during lunar EVA missions. The monitor design provides simultaneous measurement of dose-equivalent rates at two tissue-equivalent depths simulating skin and marrow. The compact personal monitor is estimated to be the size of a cell phone and would fit on an EVA spacesuit (e.g., in backpack) or in a toolbox. The four-year development effort (which began December 2007) will result in a prototype radiation monitor field tested and characterized for the major radiations expected on the surface of the Moon. We acknowledge support from NSBRI through grants to NASA Ames Research Center (T. Straume, PI) and Colorado State University (T. Borak, PI).

  6. Physiologic variability at the verge of systemic inflammation: multi-scale entropy of heart rate variability is affected by very low doses of endotoxin

    PubMed Central

    Herlitz, Georg N.; Sanders, Renee L.; Cheung, Nora H.; Coyle, Susette M.; Griffel, Benjamin; Macor, Marie A.; Lowry, Stephen F.; Calvano, Steve E.; Gale, Stephen C.

    2014-01-01

    Introduction Human injury or infection induces systemic inflammation with characteristic neuro-endocrine responses. Fluctuations in autonomic function during inflammation are reflected by beat-to-beat variation in heart rate, termed heart rate variability (HRV). In the present study, we determine threshold doses of endotoxin needed to induce observable changes in markers of systemic inflammation, we investigate whether metrics of HRV exhibit a differing threshold dose from other inflammatory markers, and we investigate the size of data sets required for meaningful use of multi-scale entropy (MSE) analysis of HRV. Methods Healthy human volunteers (n=25) were randomized to receive placebo (normal saline) or endotoxin/lipopolysaccharide (LPS): 0.1, 0.25, 0.5, 1.0, or 2.0 ng/kg administered intravenously. Vital signs were recorded every 30 minutes for 6 hours and then at 9, 12, and 24 hours after LPS. Blood samples were drawn at specific time points for cytokine measurements. HRV analysis was performed using EKG epochs of 5 minutes. MSE for HRV was calculated for all dose groups to scale factor 40. Results The lowest significant threshold dose was noted in core temperature at 0.25ng/kg. Endogenous TNF-α and IL-6 were significantly responsive at the next dosage level (0.5ng/kg) along with elevations in circulating leukocytes and heart rate. Responses were exaggerated at higher doses (1 and 2 ng/kg). Time domain and frequency domain HRV metrics similarly suggested a threshold dose, differing from placebo at 1.0 and 2.0 ng/kg, below which no clear pattern in response was evident. By applying repeated-measures ANOVA across scale factors, a significant decrease in MSE was seen at 1.0 and 2.0 ng/kg by 2 hours post exposure to LPS. While not statistically significant below 1.0 ng/kg, MSE unexpectedly decreased across all groups in an orderly dose-response pattern not seen in the other outcomes. Conclusions By usingrANOVA across scale factors, MSE can detect autonomic change after LPS challenge in a group of 25 subjects using EKG epochs of only 5 minutes and entropy analysis to scale factor of only 40, potentially facilitating MSE’s wider use as a research tool or bedside monitor. Traditional markers of inflammation generally exhibit threshold dose behavior. In contrast, MSE’s apparent continuous dose-response pattern, while not statistically verifiable in this study, suggests a potential subclinical harbinger of infectious or other insult. The possible derangement of autonomic complexity prior to or independent of the cytokine surge cannot be ruled out. Future investigation should focus on confirmation of overt inflammation following observed decreases in MSE in a clinical setting. PMID:25526373

  7. X-ray-induced changes in growth of Mozambique tilapia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jana, B.B.; Basu, M.

    1995-01-01

    Early fry (30 d postfertilization) and 7-8-week-old Mozambique tilapias (Tilapia mossambica) were exposed to X rays in dosages of 50, 100, 200, 300, 400 or 500 roentgens and reared in outdoor culture tanks between May 1981 and October 1988. Fish of either sex that were irradiated as fry grew faster than controls at all test X-ray doses. Among fish irradiated at 7-8 weeks, males grew significantly faster, but females grew significantly slower, than controls at all test doses. X-ray-induced changes in growth were dose-dependent: growth rates of fry (both sexes) and of juvenile males rose relative to those of controlsmore » with increased radiation dose. The growth increase per unit of radiation dose was higher for fry than for older juveniles. The length-weight regression was steeper for irradiated males than for controls. The average weights of F{sub 1} offspring of irradiated fish were greatly reduced as compared with controls, which suggests the transfer of the detrimental effects of X rays from irradiated parents to their offspring. 39 refs., 3 figs., 3 tabs.« less

  8. Hemodynamic effects of L-threo-3,4-dihydroxyphenylserine (Droxidopa) in hypotensive individuals with spinal cord injury.

    PubMed

    Wecht, Jill M; Rosado-Rivera, Dwindally; Weir, Joseph P; Ivan, Adrian; Yen, Christina; Bauman, William A

    2013-10-01

    To determine the effect of an escalating dose of droxidopa (100, 200, and 400 mg) compared with placebo on seated blood pressure (BP) in hypotensive individuals with spinal cord injury (SCI). Secondarily, we aimed to determine the effect of droxidopa on (1) supine BP and heart rate, (2) the change in BP and heart rate when these individuals were transferred from the supine to the seated position, and (3) adverse event (AE) reporting. Open-label dose titration trial. A Veterans Administration Medical Center. Participants with SCI (C3-T12) (N=10) were studied during 4 laboratory visits. Subjects visited the laboratory for about 5 hours on each visit, which incorporated a 30-minute seated baseline, a 30- to 60-minute supine, and a 4-hour seated postdrug observation. Placebo on visit 1, droxidopa 100 mg on visit 2, droxidopa 200 mg on visit 3, and droxidopa 400 mg on visit 4. BP and heart rate changes from baseline to the postdrug period, orthostatic heart rate and BP responses, and subjective AE reporting. Seated BP was significantly elevated with 400 mg droxidopa compared with placebo and 100 mg droxidopa for 3 hours and was elevated for 2 hours compared with 200 mg droxidopa. Increase in supine BP was not worsened following droxidopa, and the expected fall in BP when transferred to the seated position was prevented with droxidopa 200 and 400 mg. There were no significant differences in the heart rate response or AE reporting among the study visits. Our preliminary findings suggest that droxidopa, at the doses tested, does not cause excessive increases in supine BP and the 400-mg dose appears to be effective at increasing seated BP for up to 3 hours in persons with SCI. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Space Shuttle drops down the SAA doses on ISS

    NASA Astrophysics Data System (ADS)

    Dachev, T. P.; Semkova, J.; Tomov, B.; Matviichuk, Yu.; Dimitrov, Pl.; Koleva, R.; Malchev, St.; Reitz, G.; Horneck, G.; De Angelis, G.; Häder, D.-P.; Petrov, V.; Shurshakov, V.; Benghin, V.; Chernykh, I.; Drobyshev, S.; Bankov, N. G.

    2011-06-01

    Long-term analysis of data from two radiation detection instruments on the International Space Station (ISS) shows that the docking of the Space Shuttle drops down the measured dose rates in the region of the South Atlantic Anomaly (SAA) by a factor of 1.5-3. Measurements either by the R3DE detector, which is outside the ISS at the EuTEF facility on the Columbus module behind a shielding of less than 0.45 g cm -2, and by the three detectors of the Liulin-5 particle telescope, which is inside the Russian PEARS module in the spherical tissue equivalent phantom behind much heavier shielding demonstrate that effect. Simultaneously the estimated averaged incident energies of the incoming protons rise up from about 30 to 45 MeV. The effect is explained by the additional shielding against the SAA 30-150 MeV protons, provided by the 78 tons Shuttle to the instruments inside and outside of the ISS. An additional reason is the ISS attitude change (performed for the Shuttle docking) leading to decreasing of dose rates in two of Liulin-5 detectors because of the East-West proton fluxes asymmetry in SAA. The Galactic Cosmic Rays dose rates are practically not affected.

  10. Dose rate effect of pulsed electron beam on micronucleus frequency in human peripheral blood lymphocytes.

    PubMed

    Acharya, Santhosh; Sanjeev, Ganesh; Bhat, Nagesh N; Narayana, Yerol

    2010-03-01

    The micronucleus assay in human peripheral blood lymphocytes is a sensitive indicator of radiation damage and could serve as a biological dosimeter in evaluating suspected overexposure to ionising radiation. Micronucleus (MN) frequency as a measure of chromosomal damage has also extensively been employed to quantify the effects of radiation dose rate on biological systems. Here we studied the effects of 8 MeV pulsed electron beam emitted by Microtron electron accelerator on MN induction at dose rates between 35 Gy min-1 and 352.5 Gy min-1. These dose rates were achieved by varying the pulse repetition rate (PRR). Fricke dosimeter was employed to measure the absorbed dose at different PRR and to ensure uniform dose distribution of the electron beam. To study the dose rate effect, blood samples were irradiated to an absorbed dose of (4.7+/-0.2) Gy at different rates and cytogenetic damage was quantified using the micronucleus assay. The obtained MN frequency showed no dose rate dependence within the studied dose rate range. Our earlier dose effect study using 8 MeV electrons revealed that the response of MN was linear-quadratic. Therefore, in the event of an accident, dose estimation can be made using linear-quadratic dose response parameters, without adding dose rate as a correction factor.

  11. Collaborative work on evaluation of ovarian toxicity. 13) Two- or four-week repeated dose studies and fertility study of PPAR alpha/gamma dual agonist in female rats.

    PubMed

    Sato, Norihiro; Uchida, Keisuke; Nakajima, Mikio; Watanabe, Atsushi; Kohira, Terutomo

    2009-01-01

    The main focus of this study was to determine the optimal dosing period in a repeated dose toxicity study based on toxic effects as assessed by ovarian morphological changes. To assess morphological and functional changes induced in the ovary by a peroxisome proliferator-activated receptor (PPAR) alpha/gamma dual agonist, the compound was administered to female rats at dose levels of 0, 4, 20, and 100 mg/kg/day in a repeated dose toxicity study for 2 or 4 weeks, and from 2 weeks prior to mating to Day 7 of pregnancy in a female fertility study. In the repeated dose toxicity study, an increase in atresia of large follicles, a decrease in corpora lutea, and an increase in stromal cells were observed in the treated groups. In addition, the granulosa cell exfoliations into antrum of large follicles and corpora lutea with retained oocyte are morphological characteristics induced by this compound, and they might be related with abnormal condition of ovulation. In the female fertility study, the pregnancy rate tended to decrease in the 100 mg/kg/day group. At necropsy, decreases in the number of corpora lutea, implantations and live embryos were noted in the 20 and 100 mg/kg/day group. No changes were observed in animals given 4 mg/kg/day. These findings indicated that histopathological changes in the ovary are important endpoints for evaluation of drugs inducing ovarian damage. In conclusion, a 2-week administration period is sufficient to detect ovarian toxicity of this test compound in the repeated dose toxicity study.

  12. Eltoprazine counteracts l-DOPA-induced dyskinesias in Parkinson’s disease: a dose-finding study

    PubMed Central

    Rosenblad, Carl; af Edholm Arvidsson, Karolina; Wictorin, Klas; Keywood, Charlotte; Shankar, Bavani; Lowe, David A.; Björklund, Anders; Widner, Håkan

    2015-01-01

    In advanced stages of Parkinson’s disease, serotonergic terminals take up l-DOPA and convert it to dopamine. Abnormally released dopamine may participate in the development of l-DOPA-induced dyskinesias. Simultaneous activation of 5-HT1A and 5-HT1B receptors effectively blocks l-DOPA-induced dyskinesias in animal models of dopamine depletion, justifying a clinical study with eltoprazine, a 5-HT1A/B receptor agonist, against l-DOPA-induced dyskinesias in patients with Parkinson’s disease. A double-blind, randomized, placebo-controlled and dose-finding phase I/IIa study was conducted. Single oral treatment with placebo or eltoprazine, at 2.5, 5 and 7.5 mg, was tested in combination with a suprathreshold dose of l-DOPA (Sinemet®) in 22 patients with Parkinson’s disease (16 male/six female; 66.6 ± 8.8 years old) with l-DOPA-induced dyskinesias. A Wilcoxon Signed Ranked Test was used to compare each eltoprazine dose level to paired randomized placebo on the prespecified primary efficacy variables; area under the curve scores on Clinical Dyskinesia Rating Scale for 3 h post-dose and maximum change of Unified Parkinson’s Disease Rating Scale part III for 3 h post-dose. Secondary objectives included effects on maximum Clinical Dyskinesia Rating Scale score, area under the curve of Rush Dyskinesia Rating Scale score for 3 h post-dose, mood parameters measured by Hospital Anxiety Depression Scale and Montgomery Asberg Depression Rating Scale along with the pharmacokinetics, safety and tolerability profile of eltoprazine. A mixed model repeated measures was used for post hoc analyses of the area under the curve and peak Clinical Dyskinesia Rating Scale scores. It was found that serum concentrations of eltoprazine increased in a dose-proportional manner. Following levodopa challenge, 5 mg eltoprazine caused a significant reduction of l-DOPA-induced dyskinesias on area under the curves of Clinical Dyskinesia Rating Scale [–1.02(1.49); P = 0.004] and Rush Dyskinesia Rating Scale [–0.15(0.23); P = 0.003]; and maximum Clinical Dyskinesia Rating Scale score [–1.14(1.59); P = 0.005]. The post hoc analysis confirmed these results and also showed an antidyskinetic effect of 7.5 mg eltoprazine. Unified Parkinson’s Disease Rating Scale part III scores did not differ between the placebo and eltoprazine treatments. The most frequent adverse effects after eltoprazine were nausea and dizziness. It can be concluded that a single dose, oral treatment with eltoprazine has beneficial antidyskinetic effects without altering normal motor responses to l-DOPA. All doses of eltoprazine were well tolerated, with no major adverse effects. Eltoprazine has a favourable risk-benefit and pharmacokinetic profile in patients with Parkinson’s disease. The data support further clinical studies with chronic oral eltoprazine to treat l-DOPA-induced-dyskinesias. PMID:25669730

  13. Enhanced Low Dose Rate Sensitivity at Ultra-Low Dose Rates

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Pease, Ronald; Forney, James; Carts, Martin; Phan, Anthony; Cox, Stephen; Kruckmeyer, Kriby; Burns, Sam; Albarian, Rafi; Holcombe, Bruce; hide

    2011-01-01

    We have presented results of ultra-low dose rate irradiations (< or = 10 mrad(Si)/s) for a variety of radiation hardened and commercial linear bipolar devices. We observed low dose rate enhancement factors exceeding 1.5 in several parts. The worst case of dose rate enhancement resulted in functional failures, which occurred after 10 and 60 krad(Si), for devices irradiated at 0.5 and 10 mrad(Si)/s, respectively. Devices fabricated with radiation hardened processes and designs also displayed dose rate enhancement at below 10 mrad(Si)/s. Furthermore, the data indicated that these devices have not reached the damage saturation point. Therefore the degradation will likely continue to increase with increasing total dose, and the low dose rate enhancement will further magnify. The cases presented here, in addition to previous examples, illustrate the significance and pervasiveness of low dose rate enhancement at dose rates lower than 10 mrad(Si). These results present further challenges for radiation hardness assurance of bipolar linear circuits, and raise the question of whether the current standard test dose rate is conservative enough to bound degradations due to ELDRS.

  14. The Effects of ELDRS at Ultra-Low Dose Rates

    NASA Technical Reports Server (NTRS)

    Chen, Dakai; Forney, James; Carts, Martin; Phan, Anthony; Pease, Ronald; Kruckmeyer, Kirby; Cox, Stephen; LaBel, Kenneth; Burns, Samuel; Albarian, Rafi; hide

    2011-01-01

    We present results on the effects on ELDRS at dose rates of 10, 5, 1, and 0.5 mrad(Si)/s for a variety of radiation hardened and commercial devices. We observed low dose rate enhancement below 10 mrad(Si)/s in several different parts. The magnitudes of the dose rate effects vary. The TL750L, a commercial voltage regulator, showed dose rate dependence in the functional failures, with initial failures occurring after 10 krad(Si) for the parts irradiated at 0.5 mrad(Si)/s. The RH1021 showed an increase in low dose rate enhancement by 2x at 5 mrad(Si)/s relative to 8 mrad(Si)/s and high dose rate, and parametric failure after 100 krad(Si). Additionally the ELDRS-free devices, such as the LM158 and LM117, showed evidence of dose rate sensitivity in parametric degradations. Several other parts also displayed dose rate enhancement, with relatively lower degradations up to approx.15 to 20 krad(Si). The magnitudes of the dose rate enhancement will likely increase in significance at higher total dose levels.

  15. Efficacy and safety of intravenous secukinumab in noninfectious uveitis requiring steroid-sparing immunosuppressive therapy.

    PubMed

    Letko, Erik; Yeh, Steven; Foster, C Stephen; Pleyer, Uwe; Brigell, Mitchell; Grosskreutz, Cynthia L

    2015-05-01

    Secukinumab, a fully human anti-interleukin-17A monoclonal antibody, exhibited promising activity in a proof-of-concept study when administered in intravenous (IV) doses to patients with active, chronic, noninfectious uveitis. This study compared the efficacy and safety of different IV and subcutaneous (SC) doses of secukinumab in patients with noninfectious uveitis. Multicenter, randomized, double-masked, dose-ranging, phase 2 clinical trial. Thirty-seven patients with active noninfectious intermediate uveitis, posterior uveitis, or panuveitis who required corticosteroid-sparing immunosuppressive therapy. Patients were randomized to secukinumab 300 mg SC every 2 weeks for 4 doses, secukinumab 10 mg/kg IV every 2 weeks for 4 doses, or secukinumab 30 mg/kg IV every 4 weeks for 2 doses. Intravenous or SC saline was administered to maintain masking. Efficacy was assessed on day 57 (2-4 weeks after last dose). Percentage of patients with treatment response, defined as (1) at least a 2-grade reduction in vitreous haze score or trace or absent vitreous haze in the study eye without an increase in corticosteroid dose and without uveitis worsening or (2) reduction in corticosteroid dosages to prespecified levels without uveitis worsening. Percentage of patients with remission, defined as anterior chamber cell and vitreous haze scores of 0 or 0.5+ in both eyes without corticosteroid therapy or uveitis worsening. Secukinumab 30 mg/kg IV and 10 mg/kg IV, compared with the 300 mg SC dose, produced higher responder rates (72.7% and 61.5% vs. 33.3%, respectively) and remission rates (27.3% and 38.5% vs. 16.7%, respectively). Statistical and clinical superiority for the 30 mg/kg IV dose compared with the 300 mg SC dose was established in a Bayesian probability model. Other measures, including time to response onset, change in visual acuity, and change in vitreous haze score, showed numeric trends favoring IV dosing. Secukinumab, administered in IV or SC formulations, appeared safe and was well tolerated. Intravenous secukinumab was effective and well tolerated in noninfectious uveitis requiring systemic corticosteroid-sparing immunosuppressive therapy. Greater activity with IV dosing suggests that patients may not receive sufficient drug with SC administration. High-dose IV secukinumab may be necessary to deliver secukinumab in therapeutic concentrations. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  16. Dose reduction of risperidone and olanzapine can improve cognitive function and negative symptoms in stable schizophrenic patients: A single-blinded, 52-week, randomized controlled study.

    PubMed

    Zhou, Yanling; Li, Guannan; Li, Dan; Cui, Hongmei; Ning, Yuping

    2018-05-01

    The long-term effects of dose reduction of atypical antipsychotics on cognitive function and symptomatology in stable patients with schizophrenia remain unclear. We sought to determine the change in cognitive function and symptomatology after reducing risperidone or olanzapine dosage in stable schizophrenic patients. Seventy-five stabilized schizophrenic patients prescribed risperidone (≥4 mg/day) or olanzapine (≥10 mg/day) were randomly divided into a dose-reduction group ( n=37) and a maintenance group ( n=38). For the dose-reduction group, the dose of antipsychotics was reduced by 50%; for the maintenance group, the dose remained unchanged throughout the whole study. The Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, and Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) Consensus Cognitive Battery were measured at baseline, 12, 28, and 52 weeks. Linear mixed models were performed to compare the Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects and MATRICS Consensus Cognitive Battery scores between groups. The linear mixed model showed significant time by group interactions on the Positive and Negative Syndrome Scale negative symptoms, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, attention/vigilance, working memory and total score of MATRICS Consensus Cognitive Battery (all p<0.05). Post hoc analyses showed significant improvement in Positive and Negative Syndrome Scale negative subscale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, working memory and total score of MATRICS Consensus Cognitive Battery for the dose reduction group compared with those for the maintenance group (all p<0.05). This study indicated that a risperidone or olanzapine dose reduction of 50% may not lead to more severe symptomatology but can improve speed of processing, working memory and negative symptoms in patients with stabilized schizophrenia.

  17. Development of a stable and sensitive semiconductor detector by using a mixture of lead(II) iodide and lead monoxide for NDT radiation dose detection

    NASA Astrophysics Data System (ADS)

    Heo, Y. J.; Kim, K. T.; Han, M. J.; Moon, C. W.; Kim, J. E.; Park, J. K.; Park, S. K.

    2018-03-01

    Recently, high-energy radiation has been widely used in various industrial fields, including the medical industry, and increasing research efforts have been devoted to the development of radiation detectors to be used with high-energy radiation. In particular, nondestructive industrial applications use high-energy radiation for ships and multilayered objects for accurate inspection. Therefore, it is crucial to verify the accuracy of radiation dose measurements and evaluate the precision and reproducibility of the radiation output dose. Representative detectors currently used for detecting the dose in high-energy regions include Si diodes, diamond diodes, and ionization chambers. However, the process of preparing these detectors is complex in addition to the processes of conducting dosimetric measurements, analysis, and evaluation. Furthermore, the minimum size that can be prepared for a detector is limited. In the present study, the disadvantages of original detectors are compensated by the development of a detector made of a mixture of polycrystalline PbI2 and PbO powder, which are both excellent semiconducting materials suitable for detecting high-energy gamma rays and X-rays. The proposed detector shows characteristics of excellent reproducibility and stable signal detection in response to the changes in energy, and was analyzed for its applicability. Moreover, the detector was prepared through a simple process of particle-in-binder to gain control over the thickness and meet the specific value designated by the user. A mixture mass ratio with the highest reproducibility was determined through reproducibility testing with respect to changes in the photon energy. The proposed detector was evaluated for its detection response characteristics with respect to high-energy photon beam, in terms of dose-rate dependence, sensitivity, and linearity evaluation. In the reproducibility assessment, the detector made with 15 wt% PbO powder showed the best characteristics of 0.59% and 0.25% at 6 and 15 MV, respectively. Based on its selection in the reproducibility assessment, the 15 wt% PbO detector showed no dependence on the dose-rate changes, with R-SD < 1%. Finally, a coefficient of determination of 1 in the linearity assessment demonstrated very good linearity with regards to changes in dose. These results demonstrate the applicability and usefulness of the proposed detector made from a mixture of PbI2 and PbO semiconductors.

  18. Dosimetric impact of a change in breathing period on VMAT stereotactic ablative body radiotherapy

    NASA Astrophysics Data System (ADS)

    Olding, T.; Alexander, KM

    2017-05-01

    The dosimetric impact of a change in breathing period during treatment was assessed for a volumetric modulated arc therapy (VMAT) stereotactic ablative radiotherapy (SABR) lung plan optimized according to our centre’s planning protocol. Plan delivery was evaluated at three breathing rates ranging from 7 to 23 breaths-per-minute (BPM) against the planning anatomy (15 BPM) calculated dose. Dynamic ion chamber, EBT3 film and Fricke-xylenol orange-gelatin (FXG) gel measurements were acquired using a motion phantom with appropriate inserts for each dosimeter. The results show good agreement between measured and calculated plan dose within the internal gross tumour volume (IGTV) target.

  19. RadNuc: A graphical user interface to deliver dose rate patterns encountered in nuclear medicine with a 137Cs irradiator

    PubMed Central

    Pasternack, Jordan B.; Howell, Roger W.

    2012-01-01

    The temporal variations in absorbed dose rates to organs and tissues in the body are very large in diagnostic and therapeutic nuclear medicine. The response of biological endpoints of relevance to radiation safety and therapeutic efficacy are generally modulated by dose rate. Therefore, it is important to understand how the complex dose rate patterns encountered in nuclear medicine impact relevant biological responses. Accordingly, a graphical user interface (GUI) was created to control a cesium-137 irradiator to deliver such dose rate patterns. Methods Visual Basic 6.0 was used to create a user-friendly GUI to control the dose rate by varying the thickness of a mercury attenuator. The GUI facilitates the delivery of a number of dose rate patterns including constant, exponential increase or decrease, and multi-component exponential. Extensive visual feedback is provided by the GUI during both the planning and delivery stages. Results The GUI controlled irradiator can achieve a maximum dose rate of 40 cGy/hr and a minimum dose rate of 0.01 cGy/hr. Addition of machined lead blocks can be used to further reduce the minimum dose rate to 0.0001 cGy/hr. Measured dose rate patterns differed from programmed dose rate patterns in total dose by 3.2% to 8.4%. Conclusion The GUI controlled irradiator is able to accurately create dose rate patterns encountered in nuclear medicine and other related fields. This makes it an invaluable tool for studying the effects of chronic constant and variable low dose rates on biological tissues in the contexts of both radiation protection and clinical administration of internal radionuclides. PMID:23265668

  20. RadNuc: a graphical user interface to deliver dose rate patterns encountered in nuclear medicine with a 137Cs irradiator.

    PubMed

    Pasternack, Jordan B; Howell, Roger W

    2013-02-01

    The temporal variations in absorbed dose rates to organs and tissues in the body are very large in diagnostic and therapeutic nuclear medicine. The response of biological endpoints of relevance to radiation safety and therapeutic efficacy is generally modulated by dose rate. Therefore, it is important to understand how the complex dose rate patterns encountered in nuclear medicine impact relevant biological responses. Accordingly, a graphical user interface (GUI) was created to control a cesium-137 irradiator to deliver such dose rate patterns. Visual Basic 6.0 was used to create a user-friendly GUI to control the dose rate by varying the thickness of a mercury attenuator. The GUI facilitates the delivery of a number of dose rate patterns including constant, exponential increase or decrease, and multi-component exponential. Extensive visual feedback is provided by the GUI during both the planning and delivery stages. The GUI controlled irradiator can achieve a maximum dose rate of 40 cGy/h and a minimum dose rate of 0.01 cGy/h. Addition of machined lead blocks can be used to further reduce the minimum dose rate to 0.0001 cGy/h. Measured dose rate patterns differed from programmed dose rate patterns in total dose by 3.2% to 8.4%. The GUI controlled irradiator is able to accurately create dose rate patterns encountered in nuclear medicine and other related fields. This makes it an invaluable tool for studying the effects of chronic constant and variable low dose rates on biological tissues in the contexts of both radiation protection and clinical administration of internal radionuclides. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Rates of Ethanol Metabolism Decrease in Sons of Alcoholics Following a Priming Dose of Ethanol

    PubMed Central

    Bradford, Blair U.; Jackson, Jennifer K.; Powell, Linda L.; Garbutt, James C.

    2007-01-01

    Rapid changes in rates of ethanol metabolism in response to acute ethanol administration have been observed in animals and humans. To examine whether this phenomenon might vary by risk for alcoholism, 23 young men with a positive family history of alcoholism (FHP) were compared to 15 young men without a family history of alcoholism (FHN). Rates of ethanol metabolism were measured in all subjects first after an initial ethanol dose (0.85 g/kg) and then, several hours later, a second dose (0.3 g/kg), and the two rates were compared. The two groups of subjects were similar in their histories of ethanol consumption. FHP subjects demonstrated faster initial rates of ethanol metabolism, 148 ± 36 mg/kg/hr, compared to FHN subjects, 124 ± 18 mg/kg/hr, p=.01. However, FHN subjects increased their rate of metabolism by 10 ± 27 percent compared to a decrease of -15 ± 24 percent in FHP subjects, p =.007. Fifty-two percent of the FHP and none of the FHN subjects exhibited a decline in metabolic rate of 20% or more, p=.0008. Since a significant proportion of FHP subjects exhibited a decrease in the second rate of ethanol metabolism, these preliminary data might help to partly explain why FHP individuals differ in their sensitivity to ethanol and are more likely to develop alcohol dependence. PMID:17521843

  2. The Effect of Ingested Glucose Dose on the Suppression of Endogenous Glucose Production in Humans.

    PubMed

    Kowalski, Greg M; Moore, Samantha M; Hamley, Steven; Selathurai, Ahrathy; Bruce, Clinton R

    2017-09-01

    Insulin clamp studies have shown that the suppressive actions of insulin on endogenous glucose production (EGP) are markedly more sensitive than for stimulating glucose disposal ( R d ). However, clamp conditions do not adequately mimic postprandial physiological responses. Here, using the variable infusion dual-tracer approach, we used a threefold range of ingested glucose doses (25, 50, and 75 g) to investigate how physiological changes in plasma insulin influence EGP in healthy subjects. Remarkably, the glucose responses were similar for all doses tested, yet there was a dose-dependent increase in insulin secretion and plasma insulin levels. Nonetheless, EGP was suppressed with the same rapidity and magnitude (∼55%) across all doses. The progressive hyperinsulinemia, however, caused a dose-dependent increase in the estimated rates of R d , which likely accounts for the lack of a dose effect on plasma glucose excursions. This suggests that after glucose ingestion, the body preferentially permits a transient and optimal degree of postprandial hyperglycemia to efficiently enhance insulin-induced changes in glucose fluxes, thereby minimizing the demand for insulin secretion. This may represent an evolutionarily conserved mechanism that not only reduces the secretory burden on β-cells but also avoids the potential negative consequences of excessive insulin release into the systemic arterial circulation. © 2017 by the American Diabetes Association.

  3. Factors influencing botulinum toxin dose instability in spasmodic dysphonia patients.

    PubMed

    Rosow, David E; Pechman, Amanda; Saint-Victor, Sandra; Lo, Kaming; Lundy, Donna S; Casiano, Roy R

    2015-05-01

    Many patients with spasmodic dysphonia (SD) see consistent effects from botulinum toxin (BTX) injections of the same dose, whereas others require dosage changes over time. We sought to determine whether demographics (age and gender) or environmental factors (smoking) affect the long-term stability of BTX dosing in these patients. Retrospective review. Charts of all patients undergoing BTX injection for adductor SD were reviewed. Dosage change, defined as whether there was any difference in total dosage used between two beneficial injections, was used as a measure of dosing stability. Beneficial injections were indicated by a voice rating score of at least three of four and any non-zero duration of improved voice. Logistic regression analysis was performed to determine whether age, gender, smoking status, or duration of treatment correlated with odds of having a dosage change. A total of 211 patients were ultimately included. Age, gender, and smoking status were all found to have no correlative effect on dosing stability. The only factor that was predictive of dose stability was the number of previous beneficial injections, as every additional injection led to decreased odds of a change in dosage for the next injection (odds ratio=0.964; 95% confidence interval=0.947-0.981). Dosage of BTX injections for long-term treatment of SD has a significant propensity to remain stable over time. Factors such as age, gender, and smoking status do not appear to influence the dosage stability. These findings should allow for better patient counseling regarding expectations for their long-term treatment. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  4. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a causemore » for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA.« less

  5. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements

    PubMed Central

    Whitaker, May

    2016-01-01

    Purpose Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. Material and methods This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. Results The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. Conclusions The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected. PMID:27504129

  6. Robustness of IPSA optimized high-dose-rate prostate brachytherapy treatment plans to catheter displacements.

    PubMed

    Poder, Joel; Whitaker, May

    2016-06-01

    Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more uniform dwell times. This study aims to determine if the Nucletron Oncentra dwell time deviation constraint (DTDC) parameter can be optimized to improve the robustness of high-dose-rate (HDR) prostate brachytherapy plans to catheter displacements. A set of 10 clinically acceptable prostate plans were re-optimized with a DTDC parameter of 0 and 0.4. For each plan, catheter displacements of 3, 7, and 14 mm were retrospectively applied and the change in dose volume histogram (DVH) indices and conformity indices analyzed. The robustness of clinically acceptable prostate plans to catheter displacements in the caudal direction was found to be dependent on the DTDC parameter. A DTDC value of 0 improves the robustness of planning target volume (PTV) coverage to catheter displacements, whereas a DTDC value of 0.4 improves the robustness of the plans to changes in hotspots. The results indicate that if used in conjunction with a pre-treatment catheter displacement correction protocol and a tolerance of 3 mm, a DTDC value of 0.4 may produce clinically superior plans. However, the effect of the DTDC parameter in plan robustness was not observed to be as strong as initially suspected.

  7. Effect of gamma-irradiation on degradation of alginate.

    PubMed

    Lee, Dong Wook; Choi, Won Seok; Byun, Myung Woo; Park, Hyun Jin; Yu, Yong-Man; Lee, Chong M

    2003-07-30

    The aqueous solution of alginate was irradiated by 60Co gamma-rays in the dose range of 10-500 kGy. To assess the effect of irradiation on the degradation of alginate, the irradiation-induced changes in the viscosity, molecular weight, color, monomer composition, and sequence were measured. The molecular weight of raw alginate was reduced from 300000 to 25000 when irradiated at 100 kGy. The degradation rate decreased and the chain breaks per molecule increased with increasing irradiation dose. The viscosity of irradiated alginate solution reached a near minimum as low as at 10 kGy. No appreciable color changes were observed in the samples irradiated at up to 100 kGy, but intense browning occurred beyond 200 kGy. The 13C NMR spectra showed that homopolymeric blocks, MM and GG, increased and the M/G ratio decreased with irradiation. Considering both the level of degradation and the color change of alginate, the optimum irradiation dose was found to be 100 kGy.

  8. SU-F-J-104: Weekly MRI for Dose Assessment of Organs at Risk During Treatment of HN Cancer of the Oropharynx

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, K; Li, J; Venigalla, P

    2016-06-15

    Purpose: Investigate the feasibility of using weekly MRI to assess dose to organs at risk utilizing deformable image registration. Methods: Sixteen H&N patients with oropharyngeal cancer were imaged on a 3T MR scanner using T2W and mDIXON sequence. Patients were imaged on a weekly basis in treatment position. Parotids (LP & RP), submandibular glands (LS, RS), and oral cavity (OC) were delineated on the weekly MR and reviewed by a board certified radiation oncologist. The original planning CT (pCT), RT-Dose, and RT-Structures were deformed and registered to each weekly MRIs. The deformed CTs and RT-Structures were imported to the treatmentmore » planning system (TPS) and rigidly registered to the pCT. Forward dose calculation of the original RT-Plan was used to estimate the delivered dose on the deformed CT. The dose volume histograms (DVH) statistics were performed to compare planned dose, deformed dose, and forward calculated dose. In addition, Dice similarity metric (DSM) was used to compare deformed and reference structures. Results: The average (min,max) DSM between deformed and reference structures was 0.71 (0.69,0.93); 0.70 (0.64,0.89); 0.65 (0.48,0.86); 0.63 (0.37,0.89); and 0.63 (0.58,0.87); for LP, RP, LS, RS, and OC respectively. The respective average relative structures volumes changed at a weekly rate of −4.99%; −4.40%; +3.45%; +1.46%; −1.39%, respectively. The percentage difference %(min,max) between estimated delivered dose and planned dose was +3.94 (−51.3,+30.5); +6.33 (−58.6,+82.7); +2.46 (−38.9,+37.6,); +2.38(−49.0,+28.9); +3.55(−17.0,+43.1). Conclusion: The recalculated dose based on weekly MRI deviated from planned dose for all OARs. Meanwhile, the deformed dose did not reflect the subtle changes in OARs as compared to the recalculated dose. This study demonstrates the feasibility of using weekly MRI to monitor volumetric changes which has important implications on actual delivered dose.« less

  9. Dose rate in brachytherapy using after-loading machine: pulsed or high-dose rate?

    PubMed

    Hannoun-Lévi, J-M; Peiffert, D

    2014-10-01

    Since February 2014, it is no longer possible to use low-dose rate 192 iridium wires due to the end of industrial production of IRF1 and IRF2 sources. The Brachytherapy Group of the French society of radiation oncology (GC-SFRO) has recommended switching from iridium wires to after-loading machines. Two types of after-loading machines are currently available, based on the dose rate used: pulsed-dose rate or high-dose rate. In this article, we propose a comparative analysis between pulsed-dose rate and high-dose rate brachytherapy, based on biological, technological, organizational and financial considerations. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  10. Effects of Intrarenal and Intravenous Infusion of the Phosphodiesterase 3 Inhibitor Milrinone on Renin Secretion

    NASA Technical Reports Server (NTRS)

    Kumagai, Kazuhiro; Reid, Ian A.

    1994-01-01

    We have reported that administration of the phosphodiesterase III inhibitor milrinone increases renin secretion in conscious rabbits. The aim of the present study was to determine if the increase in renin secretion results from a direct renal action of milrinone, or from an indirect extrarenal effect of the drug. This was accomplished by comparing the effects of intrarenal and intravenous infusion of graded doses of milrinone on plasma renin activity in unilaterally nephrectomized conscious rabbits. Milrinone was infused into the renal artery in doses of 0.01, 0.1 and 1.0 micro-g/kg/min, and intravenously in the same rabbits in doses of 0.01, 0.1, 1.0 and 10 micro-g/kg/min. Each dose was infused for 15 min. No intrarenal dose of milrinone altered plasma renin activity or arterial pressure, although at the highest dose, there was a small increase in heart rate. Intravenous infusion of milrinone at 1.0 micro-g/kg/min increased plasma renin activity to 176 +/- 55% of the control value (P less than 0.05). Heart rate increased but arterial pressure did not change. Intravenous infusion of milrinone at 1O micro-g/kg/min increased plasma renin activity to 386 +/- 193% of control in association with a decrease in arterial pressure and an increase in heart rate. These results confirm that milrinone increases renin secretion, and indicate that the stimulation is due to an extrarenal effect of the drug.

  11. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    PubMed

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P < 0.05). No significant differences in artifact extent among different screw types and scanning positions were noted (P > 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

  12. Safety and tolerability of the γ-secretase inhibitor avagacestat in a phase 2 study of mild to moderate Alzheimer disease.

    PubMed

    Coric, Vladimir; van Dyck, Christopher H; Salloway, Stephen; Andreasen, Niels; Brody, Mark; Richter, Ralph W; Soininen, Hilkka; Thein, Stephen; Shiovitz, Thomas; Pilcher, Gary; Colby, Susan; Rollin, Linda; Dockens, Randy; Pachai, Chahin; Portelius, Erik; Andreasson, Ulf; Blennow, Kaj; Soares, Holly; Albright, Charles; Feldman, Howard H; Berman, Robert M

    2012-11-01

    To assess the safety, tolerability, and pharmacokinetic and pharmacodynamic effects of the -secretase inhibitor avagacestat in patients with mild to moderate Alzheimer disease (AD). Randomized, double-blind, placebo-controlled,24-week phase 2 study. Global, multicenter trial. A total of 209 outpatients with mild to moderate AD were randomized into the double-blind treatment phase. The median age of the patients was 75 years,58.9% were APOE ε4 carriers, and baseline measures of disease severity were similar among groups. Avagacestat, 25, 50, 100, or 125 mg daily,or placebo administered orally daily. Safety and tolerability of avagacestat. Discontinuation rates for the 25-mg and 50-mg doses of avagacestat were comparable with placebo but were higher in the 100-mg and 125-mg dose groups.Trends for worsening cognition, as measured by change from baseline Alzheimer Disease Assessment Scale cognitive subscale score, were observed in the 100-mg and125-mg dose groups. Treatment-emergent serious adverse events were similar across placebo and treatment groups. The most common reason for discontinuation was adverse events, predominantly gastrointestinal anddermatologic. Other adverse events occurring more frequentlyin patients undergoing treatment included reversibleglycosuria (without associated serum glucose changes), nonmelanoma skin cancer, and asymptomaticmagnetic resonance imaging findings. Exploratory cerebrospinal fluid amyloid isoforms and tau biomarker analysis demonstrated dose-dependent but not statistically significant reductions in a small subset of patients. Avagacestat dosed at 25 and 50 mg daily was relatively well tolerated and had low discontinuation rates. The 100-mg and 125-mg dose arms were poorly tolerated with trends for cognitive worsening. Exploratory cerebrospinal fluid biomarker substudies provide preliminary support for -secretase target engagement,but additional studies are warranted to better characterize pharmacodynamic effects at the 25- and 50-mg doses.This study establishes an acceptable safety and tolerability dose range for future avagacestat studies in AD. clinicaltrials.gov Identifier: NCT00810147

  13. [Myocardial electrogenesis in laboratory rats under conditions of acute nitrite intoxication].

    PubMed

    Shumilova, T E; Shereshkov, V I; Ianvareva, I N; Nozdrachev, A D

    2010-01-01

    In anesthetized male rats the arterial blood pressure in femoral artery and electrocardiogram in standard leads were recorded uninterruptedly for 1-1.5 h under conditions of acute nitrite intoxication produced by a subcutaneous injection of water solution of sodium nitrite (donor of nitric oxide) at concentrations of 10, 30, and 50 mg/kg body mass. Results of the study have shown dose-dependent changes of arterial pressure as well as of time and amplitude characteristics of electrocardiogram under effect of NaNO2. At the threshold hypoxic dose, an increase of amplitude of R and S waves was observed by the 30-45th min, while at the maximal NaNO2 dose, amplitude of all waves rose by the 15th min of intoxication. High nitric doses often caused an increase of the ST segment above the isoelectric line and a rise of the amplitude of the T wave, on which a notch appeared in some cases. The change of the ECG time parameters was expressed in the dose-dependent development of bradycardia for the first 4-7 min; its level correlated with the progressively decreasing arterial pressure in the beginning (the 2-4th min) of nitrite intoxication. Variation analysis of heart rate spectral characteristics by Baevskii has revealed a rise of the total spectral power of pulse oscillations. Under effect of nitrite, in the spectrum of cardiointervals, quent recovery of the normal ECG spectrum in the end of the experimental period. The maximal nitrite dose produced more pronounced shifts of the heart rate spectrum towards the LF and VLF diapasons that were not restored for 1 h of experiment. Transitory processes of readjustment of the cardiac rhythm had discrete character. The nitrite dose of 50 mg/kg body mass increased the RR-interval after 4-7 min with amplitude steps of 3-5 imp/s and the time constant of 20-40 s. The revealed ECG changes had the reflex (enhancement of parasympathetic tonus) and metabolic (the hypoxic and histotoxic damage of myocardium) nature.

  14. Effects of chronic external gamma irradiation on growth and reproductive success of Daphnia magna.

    PubMed

    Gilbin, Rodolphe; Alonzo, Frédéric; Garnier-Laplace, Jacqueline

    2008-01-01

    Aquatic invertebrates (water flea Daphnia magna) were exposed to low dose rates of external gamma radiation (from 0.4 to 31mGyh(-1)) over a 23-day period (i.e. 5 broods). Gamma radiation caused changes in neither survival nor somatic growth. Mass-specific respiration rate was significantly lower at 31mGyh(-1) than in the control. Reproduction was affected through early release and reduced size of broods after 15 days of exposure at 31mGyh(-1) (broods 3-5), resulting in a 21% fecundity decrease at 31mGyh(-1) compared to the control. A decreased resistance of neonates to starvation was observed in relation to dose rates. Possible mechanisms of gamma radiotoxicity for daphnid reproduction and implications for radioprotection are discussed.

  15. Prototype Operational Advances for Atmospheric Radiation Dose Rate Specification

    NASA Astrophysics Data System (ADS)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Garrett, H. B.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, D.; Mertens, C. J.; Xu, X.; Crowley, G.; Reynolds, A.; Azeem, I.; Wiltberger, M. J.; Wiley, S.; Bacon, S.; Teets, E.; Sim, A.; Dominik, L.

    2014-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. The coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has developed innovative, new space weather observations that will become part of the toolset that is transitioned into operational use. One prototype operational system for providing timely information about the effects of space weather is SET's Automated Radiation Measurements for Aerospace Safety (ARMAS) system. ARMAS will provide the "weather" of the radiation environment to improve aircraft crew and passenger safety. Through several dozen flights the ARMAS project has successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time via Iridium satellites, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. We are extending the dose measurement domain above commercial aviation altitudes into the stratosphere with a collaborative project organized by NASA's Armstrong Flight Research Center (AFRC) called Upper-atmospheric Space and Earth Weather eXperiment (USEWX). In USEWX we will be flying on the ER-2 high altitude aircraft a micro dosimeter for effective dose rate measurements and a thermal neutron monitor to characterize Single Event Effects (SEEs) in avionics. In this presentation we describe recent ARMAS and USEWX advances that will ultimately provide operational users with real-time dose and dose rate data for human tissue and avionics exposure risk mitigation.

  16. Pseudoephedrine: effects on milk production in women and estimation of infant exposure via breastmilk

    PubMed Central

    Aljazaf, Khalidah; Hale, Thomas W; Ilett, Kenneth F; Hartmann, Peter E; Mitoulas, Leon R; Kristensen, Judith H; Hackett, L Peter

    2003-01-01

    Aims To assess the effects of pseudoephedrine on breast blood flow, temperature and milk production, and to estimate the likely infant dose during breastfeeding. Methods Eight lactating women (mean age 35 years and weight 69 kg) participated in a single-blind randomized crossover study of 60 mg pseudoephedrine hydrochloride vs placebo. Breast blood flow and surface temperature were measured from 0 to 4 h following the dose, and change in plasma prolactin was measured as the difference between predose and 1 h postdose concentrations. Milk production was measured for 24 h following placebo and pseudoephedrine. Infant dose of pseudoephedrine for a 60-mg dose administered four times daily to the mother was quantified as the product of average steady-state drug concentration in milk and an estimated milk production rate of 0.15 l kg−1 day−1 and expressed relative to the maternal weight-adjusted dose. Results There were no physiologically significant changes in breast blood flow or temperature between the placebo and pseudoephedrine periods. The mean change in plasma prolactin was slightly (13.5%), but not significantly lower (t = 1.245, P = 0.253) after pseudoephedrine (1775 mU l−1) compared with placebo (2014 mU l−1). However, the mean milk volume was reduced by 24% from 784 ml day−1 in the placebo period to 623 ml day−1 in the pseudoephedrine period (difference between means 161 ml day−1 (95% CI: 63, 259 ml day−1); t = 3.9, P = 0.006). Assuming maternal intake of 60 mg pseudoephedrine hydrochloride four times daily, the estimated infant dose of pseudoephedrine was 4.3% (95% CI, 3.2, 5.4%) of the weight-adjusted maternal dose. Conclusions A single dose of pseudoephedrine significantly reduced milk production. This effect was not attributable to changes in blood flow, but depression of prolactin secretion may be a contributing factor. At the maximum recommended pseudoephedrine doses, the calculated infant dose delivered via milk was < 10% of the maternal dose, and is unlikely to affect the infant adversely. The ability of pseudoephedrine to suppress lactation suggests a novel use for the drug. PMID:12848771

  17. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging.

    PubMed

    Zwan, Benjamin J; Barnes, Michael P; Hindmarsh, Jonathan; Lim, Seng B; Lovelock, Dale M; Fuangrod, Todsaporn; O'Connor, Daryl J; Keall, Paul J; Greer, Peter B

    2017-08-01

    An ideal commissioning and quality assurance (QA) program for Volumetric Modulated Arc Therapy (VMAT) delivery systems should assess the performance of each individual dynamic component as a function of gantry angle. Procedures within such a program should also be time-efficient, independent of the delivery system and be sensitive to all types of errors. The purpose of this work is to develop a system for automated time-resolved commissioning and QA of VMAT control systems which meets these criteria. The procedures developed within this work rely solely on images obtained, using an electronic portal imaging device (EPID) without the presence of a phantom. During the delivery of specially designed VMAT test plans, EPID frames were acquired at 9.5 Hz, using a frame grabber. The set of test plans was developed to individually assess the performance of the dose delivery and multileaf collimator (MLC) control systems under varying levels of delivery complexities. An in-house software tool was developed to automatically extract features from the EPID images and evaluate the following characteristics as a function of gantry angle: dose delivery accuracy, dose rate constancy, beam profile constancy, gantry speed constancy, dynamic MLC positioning accuracy, MLC speed and acceleration constancy, and synchronization between gantry angle, MLC positioning and dose rate. Machine log files were also acquired during each delivery and subsequently compared to information extracted from EPID image frames. The largest difference between measured and planned dose at any gantry angle was 0.8% which correlated with rapid changes in dose rate and gantry speed. For all other test plans, the dose delivered was within 0.25% of the planned dose for all gantry angles. Profile constancy was not found to vary with gantry angle for tests where gantry speed and dose rate were constant, however, for tests with varying dose rate and gantry speed, segments with lower dose rate and higher gantry speed exhibited less profile stability. MLC positional accuracy was not observed to be dependent on the degree of interdigitation. MLC speed was measured for each individual leaf and slower leaf speeds were shown to be compensated for by lower dose rates. The test procedures were found to be sensitive to 1 mm systematic MLC errors, 1 mm random MLC errors, 0.4 mm MLC gap errors and synchronization errors between the MLC, dose rate and gantry angle controls systems of 1°. In general, parameters measured by both EPID and log files agreed with the plan, however, a greater average departure from the plan was evidenced by the EPID measurements. QA test plans and analysis methods have been developed to assess the performance of each dynamic component of VMAT deliveries individually and as a function of gantry angle. This methodology relies solely on time-resolved EPID imaging without the presence of a phantom and has been shown to be sensitive to a range of delivery errors. The procedures developed in this work are both comprehensive and time-efficient and can be used for streamlined commissioning and QA of VMAT delivery systems. © 2017 American Association of Physicists in Medicine.

  18. A centrally mediated prolonged hypotension produced by oxotremorine or pilocarpine

    PubMed Central

    Dage, R.C.

    1979-01-01

    1 Oxotremorine, methyloxotremorine, pilocarpine or arecoline were given intravenously to anaesthetized cats, dogs or rats, and intraperitoneally to conscious normotensive and spontaneously hypertensive rats, pretreated with doses of methylatropine that completely blocked peripheral muscarinic receptors, to ascertain their effects on blood pressure and heart rate. 2 Oxotremorine but not methyloxotremorine produced a prolonged hypotension in cats and dogs but not in rats. Heart rate was not changed. Pilocarpine, although less potent, produced an identical effect, whereas the effect of arecoline was short by comparison. The hypotensive effect of these drugs was reversed by atropine. 3 In dogs, oxotremorine produced a prolonged hypotension with no change in heart rate or cardiac output. 4 A decrease in spontaneous sympathetic nerve activity accompanied the hypotension in cats. Both effects were reversed by atropine but could be reinvoked by large doses of oxotremorine. 5 The oxotremorine-induced hypotension in cats was not altered by decerebration but was abolished by high cervical spinal section. 6 The results indicate that the prolonged hypotension elicited by oxotremorine is mediated by an action at muscarinic receptors in the brain stem resulting in a decrease in sympathetic nerve activity and peripheral resistance but not heart rate or cardiac output. PMID:760887

  19. [The value of the thermocouple in the measurement of the gastric mucosal blood-flow. The influence of the occlusion of the celiac artery and prostaglandin E1 on the gastric mucosal blood flow. An experimental study in animals (author's transl)].

    PubMed

    Koch, H; Demling, L

    1976-02-27

    The study has been carried out to ensure the positive evidence of the measurement of the gastric mucosal blood-flow with the aid of the thermocouple (heat-clearance technique). The experiments have shown that the suction pressure of 600 mm mercury column which was used to fix the Thermocouple to the mucosa was indispensable in order to assess the blood-flow in the entire depth of the mucosa. Changes in the mucosal blood-flow are measuured at the same rate in all quadrants of the gastric corpus. The measuring of the blood-flow of a well circumscribed area of the mucosa is therefore representative for the entire corpus. Vasopressin led to a significant reduction of the gastric mucosal blood-flow measured with heat-clearance as well aminopyrine-clearance. There was a linear correlation between the results of both methods. Vasopressin selectively reduces the blood-flow of the gastric mucosa but not of the submucosa, the muscular layer and the serosa. Therefore it seems to be probable that changes in mucosal blood-flow selectively can be measured with the aid of the thermocouple. After previous stimulation with pentagastrin neither mucosal blood-flow nor acid secretion of the stomach were influenced by the occlusion of the celiac artery by 25 %. The occlusion of the celiac artery by 50 % reduced significantly the pentagastrin-stimulated gastric mucosal blood-flow whereas the acid secretion was not influenced. Prostaglandin E1 at a dose rate of 2 mug/kg-h increased significantly arterial and mucosal blood-flow as well as acid secretion of the stomach. In comparison PGE1 administered at a dose rate of 4 mug/kg-h reduced significantly gastric mucosal blood-flow and gastric secretion. PGE1 at a dose rate of 8 mug/kg-h did not produce any significant changes in blood-flow and secretion. The results suggested that the changes of gastric secretion observed with PGE1 were the consequence of primary changes in the gastric mucosal blood-flow.

  20. Human psychopharmacology and dose-effects of salvinorin A, a kappa opioid agonist hallucinogen present in the plant Salvia divinorum.

    PubMed

    Johnson, Matthew W; MacLean, Katherine A; Reissig, Chad J; Prisinzano, Thomas E; Griffiths, Roland R

    2011-05-01

    Salvinorin A is a potent, selective nonnitrogenous kappa opioid agonist and the known psychoactive constituent of Salvia divinorum, a member of the mint family that has been used for centuries by Mazatec shamans of Mexico for divination and spiritual healing. S. divinorum has over the last several years gained increased popularity as a recreational drug. This is a double-blind, placebo controlled study of salvinorin A in 4 psychologically and physically healthy hallucinogen-using adults. Across sessions, participants inhaled 16 ascending doses of salvinorin A and 4 intermixed placebo doses under comfortable and supportive conditions. Doses ranged from 0.375 μg/kg to 21 μg/kg. Subject-rated drug strength was assessed every 2 min for 60 min after inhalation. Orderly time- and dose-related effects were observed. Drug strength ratings peaked at 2 min (first time point) and definite subjective effects were no longer present at approximately 20 min after inhalation. Dose-related increases were observed on questionnaire measures of mystical-type experience (Mysticism Scale) and subjective effects associated with classic serotonergic (5-HT2(A)) hallucinogens (Hallucinogen Rating Scale). Salvinorin A did not significantly increase heart rate or blood pressure. Participant narratives indicated intense experiences characterized by disruptions in vestibular and interoceptive signals (e.g., change in spatial orientation, pressure on the body) and unusual and sometimes recurring themes across sessions such as revisiting childhood memories, cartoon-like imagery, and contact with entities. Under these prepared and supportive conditions, salvinorin A occasioned a unique profile of subjective effects having similarities to classic hallucinogens, including mystical-type effects. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  1. The effects of booster vaccination on combined hepatitis A and hepatitis B vaccine in both anti-HBs and anti-HAV negative children 5-15 years after hepatitis B vaccine primary immunization.

    PubMed

    Chen, Yongdi; Gu, Hua; Cheng, Suyun; Shen, Lingzhi; Cui, Fujiang; Wang, Fuzhen; Yao, Jun; Xia, Shichang; Lv, Huakun; Liang, Xiaofeng

    2013-04-01

    In the present study, we investigated the changes in both anti-HAV lgG and anti-HBs lgG levels and compared the antibody seroconversion rates of different doses of combined hepatitis A and hepatitis B vaccine in children. Children who were vaccinated as infants with Hepatitis B vaccine were revaccinated at 5-15 y of age, then the antibody titers were monitored. Among 283 children, this study found that the anti-HAV seroconversion rates (defined as anti-HAV ≥ 1 mIU/ml) after the first and the third dose were 79.9% and 100% respectively; these observed differences were statistically significant (P<0.05); the corresponding geometric mean titers (GMTs) were 4.72 ± 2.63 mIU/ml and 13.46 ± 1.16 mIU/ml respectively. The anti-HBs seroconversion rates (defined as an anti-HBs ≥ 10 mIU/ml) were 82.3% and 99.0% respectively; these observed differences were statistically significant (P<0.05); and the corresponding titers were 319.95 ± 5.16 mIU/ml and 418.59 ± 3.89 mIU/ml respectively. After the first booster dose, the difference in anti-HAV seroconversion rate was statistically significant in children aged 5-9 y and 10-15 y (P<0.05), as was the difference of anti-HBs seroconversion, whereas after the third dose the difference was not statistically significant (P>0.05). This study demonstrated that the immunization effects of booster vaccination with combined hepatitis A and hepatitis B vaccine is successful for children. A single booster dose is adequate for younger children, while three doses are needed for older children.

  2. Defibrotide for the Treatment of Severe Hepatic Veno-Occlusive Disease and Multiorgan Failure after Stem Cell Transplantation: A Multicenter, Randomized, Dose-Finding Trial

    PubMed Central

    Richardson, Paul G.; Soiffer, Robert J.; Antin, Joseph H.; Uno, Hajime; Jin, Zhezhen; Kurtzberg, Joanne; Martin, Paul L.; Steinbach, Gideon; Murray, Karen F.; Vogelsang, Georgia B.; Chen, Allen R.; Krishnan, Amrita; Kernan, Nancy A.; Avigan, David E.; Spitzer, Thomas R.; Shulman, Howard M.; Di Salvo, Donald N.; Revta, Carolyn; Warren, Diane; Momtaz, Parisa; Bradwin, Gary; Wei, L. J.; Iacobelli, Massimo; McDonald, George B.; Guinan, Eva C.

    2010-01-01

    Therapeutic options for severe hepatic veno-occlusive disease (VOD) are limited and outcomes are dismal, but early phase I/II studies have suggested promising activity and acceptable toxicity using the novel polydisperse oligonucleotide defibrotide. This randomized phase II dose-finding trial determined the efficacy of defibrotide in patients with severe VOD following hematopoietic stem cell transplantation (HSCT) and identified an appropriate dose for future trials. Adult and pediatric patients received either lower-dose (arm A: 25 mg/kg/day; n = 75) or higher-dose (arm B: 40 mg/kg/day; n = 74) i.v. defibrotide administered in divided doses every 6 hours for ≥ 14 days or until complete response, VOD progression, or any unacceptable toxicity occurred. Overall complete response and day + 100 post-HSCT survival rates were 46% and 42%, respectively, with no significant difference between treatment arms. The incidence of treatment-related adverse events was low (8% overall; 7% in arm A, 10% in arm B); there was no significant difference in the overall rate of adverse events between treatment arms. Early stabilization or decreased bilirubin was associated with better response and day + 100 survival, and decreased plasminogen activator inhibitor type 1 (PAI-1) during treatment was associated with better outcome; changes were similar in both treatment arms. Defibrotide 25 or 40 mg/kg/day also appears effective in treating severe VOD following HSCT. In the absence of any differences in activity, toxicity or changes in PAI-1 level, defibrotide 25 mg/kg/day was selected for ongoing phase III trials in VOD. PMID:20167278

  3. Cardiovascular changes in atherosclerotic ApoE-deficient mice exposed to Co60 (γ) radiation.

    PubMed

    Kumarathasan, Prem; Vincent, Renaud; Blais, Erica; Saravanamuthu, Anu; Gupta, Pallavi; Wyatt, Heather; Mitchel, Ronald; Hannan, Mohammed; Trivedi, Akilesh; Whitman, Stewart

    2013-01-01

    There is evidence for a role of ionizing radiation in cardiovascular diseases. The goal of this work was to identify changes in oxidative and nitrative stress pathways and the status of the endothelinergic system during progression of atherosclerosis in ApoE-deficient mice after single and repeated exposure to ionizing radiation. B6.129P2-ApoE tmlUnc mice on a low-fat diet were acutely exposed (whole body) to Co60 (γ) (single dose 0, 0.5, and 2 Gy) at a dose rate of 36.32 cGy/min, or repeatedly (cumulative dose 0 and 2 Gy) at a dose-rate of 0.1 cGy/min for 5 d/wk, over a period of 4 weeks. Biological endpoints were investigated after 3-6 months of recovery post-radiation. The nitrative stress marker 3-nitrotyrosine and the vasoregulator peptides endothelin-1 and endothelin-3 in plasma were increased (p<0.05) in a dose-dependent manner 3-6 months after acute or chronic exposure to radiation. The oxidative stress marker 8-isoprostane was not affected by radiation, while plasma 8-hydroxydeoxyguanosine and L-3,4-dihydroxyphenylalanine decreased (p<0.05) after treatment. At 2Gy radiation dose, serum cholesterol was increased (p = 0.008) relative to controls. Percent lesion area increased (p = 0.005) with age of animal, but not with radiation treatment. Our observations are consistent with persistent nitrative stress and activation of the endothelinergic system in ApoE-/- mice after low-level ionizing radiation exposures. These mechanisms are known factors in the progression of atherosclerosis and other cardiovascular diseases.

  4. Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak.

    PubMed

    Dauber, I M; Pluss, W T; VanGrondelle, A; Trow, R S; Weil, J V

    1985-08-01

    Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. We tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin (131I) and erythrocytes (99mTc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. We calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability we normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. We measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity we compared hydrostatic and high-dose thiourea edema. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 X 10-4 vs. 7.6 +/- 0.9 X 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 X 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity we compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water. We conclude that a noninvasive double radioisotope measurement of pulmonary vascular protein leak, employing external counting techniques and a simplified method of calculation, is specific for lung injury and is also sensitive enough to detect lung injury insufficient to produce detectable pulmonary edema.

  5. Levels of daily light doses under changed day-night cycles regulate temporal segregation of photosynthesis and N2 Fixation in the cyanobacterium Trichodesmium erythraeum IMS101.

    PubMed

    Cai, Xiaoni; Gao, Kunshan

    2015-01-01

    While the diazotrophic cyanobacterium Trichodesmium is known to display inverse diurnal performances of photosynthesis and N2 fixation, such a phenomenon has not been well documented under different day-night (L-D) cycles and different levels of light dose exposed to the cells. Here, we show differences in growth, N2 fixation and photosynthetic carbon fixation as well as photochemical performances of Trichodesmium IMS101 grown under 12L:12D, 8L:16D and 16L:8D L-D cycles at 70 μmol photons m-2 s-1 PAR (LL) and 350 μmol photons m-2 s-1 PAR (HL). The specific growth rate was the highest under LL and the lowest under HL under 16L:8D, and it increased under LL and decreased under HL with increased levels of daytime light doses exposed under the different light regimes, respectively. N2 fixation and photosynthetic carbon fixation were affected differentially by changes in the day-night regimes, with the former increasing directly under LL with increased daytime light doses and decreased under HL over growth-saturating light levels. Temporal segregation of N2 fixation from photosynthetic carbon fixation was evidenced under all day-night regimes, showing a time lag between the peak in N2 fixation and dip in carbon fixation. Elongation of light period led to higher N2 fixation rate under LL than under HL, while shortening the light exposure to 8 h delayed the N2 fixation peaking time (at the end of light period) and extended it to night period. Photosynthetic carbon fixation rates and transfer of light photons were always higher under HL than LL, regardless of the day-night cycles. Conclusively, diel performance of N2 fixation possesses functional plasticity, which was regulated by levels of light energy supplies either via changing light levels or length of light exposure.

  6. Comparison of Levalbuterol and Racemic Albuterol Based on Cardiac Adverse Effects in Children

    PubMed Central

    Bio, Laura L.; Willey, Vincent J.; Poon, Cathy Y.

    2011-01-01

    OBJECTIVE To compare the cardiac effects of levalbuterol with those of racemic albuterol based on changes in heart rate (HR) in pediatric patients. METHODS The medical records of hospitalized children ages 1 month to 12 years, who received either levalbuterol or racemic albuterol via nebulizer for 3 consecutive doses between January 2006 and December 2008 were reviewed. The documented HR was collected prior to and after each administered dose of bronchodilator. The primary outcome was the largest percentage of change in HR between groups. Secondary outcomes of comparisons of the number of patients who had more than a 10% change in HR and incidence of tachycardia were included. RESULTS A total of 50 patients, 25 in each group, was included in the study. All patients in the racemic albuterol group received 2.5 mg per dose, while most of the patients in the levalbuterol group received 0.63 mg per dose (19 patients, 76%). Only 6 levalbuterol patients received a dose of 1.25 mg. Nineteen of 25 patients (76%) in the levalbuterol group were tachycardic prior to the first recorded dose compared to 15 patients (60%) in the racemic albuterol group (p = 0.36). The median of the largest percentage of change in HR was 4.1% (interquartile range [IQR], 1.8–8.7) in the levalbuterol group compared to 5% (IQR, 1.9–7.8) in the racemic albuterol group (p = 0.763). Four patients in the levalbuterol group experienced an HR increase of more than 10% compared to 5 patients in the racemic albuterol group (p = 1.0). CONCLUSION Levalbuterol and racemic albuterol bronchodilator therapies produced similar effects on HR. No clinically significant differences were detected in HR changes between the two treatment groups, despite administration of a larger equipotent albuterol dose in the racemic albuterol group than in the levalbuterol group. PMID:22479161

  7. Effects of dose scaling on delivery quality assurance in tomotherapy

    PubMed Central

    Nalichowski, Adrian; Burmeister, Jay

    2012-01-01

    Delivery quality assurance (DQA) of tomotherapy plans is routinely performed with silver halide film which has a limited range due to the effects of saturation. DQA plans with dose values exceeding this limit require the dose of the entire plan to be scaled downward if film is used, to evaluate the dose distribution in two dimensions. The potential loss of fidelity between scaled and unscaled DQA plans as a function of dose scaling is investigated. Three treatment plans for 12 Gy fractions designed for SBRT of the lung were used to create DQA procedures that were scaled between 100% and 10%. The dose was measured with an ionization chamber array and compared to values from the tomotherapy treatment planning system. Film and cylindrical ion chamber measurements were also made for one patient for scaling factors of 50% to 10% to compare with the ionization chamber array measurements. The array results show the average gamma pass rate is ≥99% from 100% to 30% scaling. The average gamma pass rate falls to 93.6% and 51.1% at 20% and 10% scaling, respectively. Film analysis yields similar pass rates. Cylindrical ion chambers did not exhibit significant variation with dose scaling, but only represent points in the low gradient region of the dose distribution. Scaling the dose changes the mechanics of the radiation delivery, as well as the signal‐to‐noise ratio. Treatment plans which exhibit parameters that differ significantly from those common to DQA plans studied in this paper may exhibit different behavior. Dose scaling should be limited to the smallest degree possible. Planar information, such as that from film or a detector array, is required. The results show that it is not necessary to perform both a scaled and unscaled DQA plan for the treatment plans considered here. PACS numbers: 87.55.km, 87.55.Qr PMID:22231213

  8. Effects of acute buspirone administration on inhibitory control and sexual discounting in cocaine users.

    PubMed

    Strickland, Justin C; Bolin, B Levi; Romanelli, Michael R; Rush, Craig R; Stoops, William W

    2017-01-01

    Cocaine users display deficits in inhibitory control and make impulsive choices that may increase risky behavior. Buspirone is an anxiolytic that activates dopaminergic and serotonergic systems and improves impulsive choice (i.e., reduces sexual risk-taking intent) in cocaine users when administered chronically. We evaluated the effects of acutely administered buspirone on inhibitory control and impulsive choice. Eleven subjects with a recent history of cocaine use completed this within-subject, placebo-controlled study. Subjects performed two cued go/no-go and a sexual risk delay-discounting task following oral administration of buspirone (10 and 30 mg), triazolam (0.375 mg; positive control), and placebo (negative control). Physiological and psychomotor performance and subject-rated data were also collected. Buspirone failed to change inhibitory control or impulsive choice; however, slower reaction times were observed at the highest dose tested. Buspirone did not produce subject-rated drug effects but dose-dependently decreased diastolic blood pressure. Triazolam impaired psychomotor performance and increased ratings of positive subject-rated effects (e.g., Like Drug). These findings indicate that acutely administered buspirone has little impact on behavioral measures of inhibitory control and impulsive sexual decision-making. Considering previous findings with chronic dosing, these findings highlight that the behavioral effects of buspirone differ as a function of dosing conditions. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Dose rate effects in the radiation damage of the plastic scintillators of the CMS hadron endcap calorimeter

    DOE PAGES

    Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; ...

    2016-10-07

    We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. Here, we show that the scaling with dose rate is consistent with that expected from diffusion effects.

  10. Characterizing dose response relationships: Chronic gamma radiation in Lemna minor induces oxidative stress and altered polyploidy level.

    PubMed

    Van Hoeck, Arne; Horemans, Nele; Van Hees, May; Nauts, Robin; Knapen, Dries; Vandenhove, Hildegarde; Blust, Ronny

    2015-12-01

    The biological effects and interactions of different radiation types in plants are still far from understood. Among different radiation types, external gamma radiation treatments have been mostly studied to assess the biological impact of radiation toxicity in organisms. Upon exposure of plants to gamma radiation, ionisation events can cause, either directly or indirectly, severe biological damage to DNA and other biomolecules. However, the biological responses and oxidative stress related mechanisms under chronic radiation conditions are poorly understood in plant systems. In the following study, it was questioned if the Lemna minor growth inhibition test is a suitable approach to also assess the radiotoxicity of this freshwater plant. Therefore, L. minor plants were continuously exposed for seven days to 12 different dose rate levels covering almost six orders of magnitude starting from 80 μGy h(-1) up to 1.5 Gy h(-1). Subsequently, growth, antioxidative defence system and genomic responses of L. minor plants were evaluated. Although L. minor plants could survive the exposure treatment at environmental relevant exposure conditions, higher dose rate levels induced dose dependent growth inhibitions starting from approximately 27 mGy h(-1). A ten-percentage growth inhibition of frond area Effective Dose Rate (EDR10) was estimated at 95 ± 7 mGy h(-1), followed by 153 ± 13 mGy h(-1) and 169 ± 12 mGy h(-1) on fresh weight and frond number, respectively. Up to a dose rate of approximately 5 mGy h(-1), antioxidative enzymes and metabolites remained unaffected in plants. A significant change in catalase enzyme activity was found at 27 mGy h(-1) which was accompanied with significant increases of other antioxidative enzyme activities and shifts in ascorbate and glutathione content at higher dose rate levels, indicating an increase in oxidative stress in plants. Recent plant research hypothesized that environmental genotoxic stress conditions can induce endoreduplication events. Here an increase in ploidy level was observed at the highest tested dose rate. In conclusion, the results revealed that in plants several mechanisms and pathways interplay to cope with radiation induced stress. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters

    PubMed Central

    Werner, René

    2017-01-01

    Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail–which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm γ-evaluation, with the measured dose distributions serving as ground truth. Overall γ-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% ± 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that–in the sense of 4D QA of VMAT treatment plans–allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies. PMID:28231337

  12. 4D dose simulation in volumetric arc therapy: Accuracy and affecting parameters.

    PubMed

    Sothmann, Thilo; Gauer, Tobias; Werner, René

    2017-01-01

    Radiotherapy of lung and liver lesions has changed from normofractioned 3D-CRT to stereotactic treatment in a single or few fractions, often employing volumetric arc therapy (VMAT)-based techniques. Potential unintended interference of respiratory target motion and dynamically changing beam parameters during VMAT dose delivery motivates establishing 4D quality assurance (4D QA) procedures to assess appropriateness of generated VMAT treatment plans when taking into account patient-specific motion characteristics. Current approaches are motion phantom-based 4D QA and image-based 4D VMAT dose simulation. Whereas phantom-based 4D QA is usually restricted to a small number of measurements, the computational approaches allow simulating many motion scenarios. However, 4D VMAT dose simulation depends on various input parameters, influencing estimated doses along with mitigating simulation reliability. Thus, aiming at routine use of simulation-based 4D VMAT QA, the impact of such parameters as well as the overall accuracy of the 4D VMAT dose simulation has to be studied in detail-which is the topic of the present work. In detail, we introduce the principles of 4D VMAT dose simulation, identify influencing parameters and assess their impact on 4D dose simulation accuracy by comparison of simulated motion-affected dose distributions to corresponding dosimetric motion phantom measurements. Exploiting an ITV-based treatment planning approach, VMAT treatment plans were generated for a motion phantom and different motion scenarios (sinusoidal motion of different period/direction; regular/irregular motion). 4D VMAT dose simulation results and dose measurements were compared by local 3% / 3 mm γ-evaluation, with the measured dose distributions serving as ground truth. Overall γ-passing rates of simulations and dynamic measurements ranged from 97% to 100% (mean across all motion scenarios: 98% ± 1%); corresponding values for comparison of different day repeat measurements were between 98% and 100%. Parameters of major influence on 4D VMAT dose simulation accuracy were the degree of temporal discretization of the dose delivery process (the higher, the better) and correct alignment of the assumed breathing phases at the beginning of the dose measurements and simulations. Given the high γ-passing rates between simulated motion-affected doses and dynamic measurements, we consider the simulations to provide a reliable basis for assessment of VMAT motion effects that-in the sense of 4D QA of VMAT treatment plans-allows to verify target coverage in hypofractioned VMAT-based radiotherapy of moving targets. Remaining differences between measurements and simulations motivate, however, further detailed studies.

  13. Radiation dose effect of DNA repair-related gene expression in mouse white blood cells.

    PubMed

    Li, Ming-juan; Wang, Wei-wei; Chen, Shi-wei; Shen, Qian; Min, Rui

    2011-10-01

    The aim of this study was to screen molecular biomarkers for biodosimetry from DNA repair-related gene expression profiles. Mice were subjected to whole-body exposure with 60Co gamma rays with a dose range of 0-8 Gy at a dose rate of 0.80 Gy/min. RNA was extracted from the peripheral blood of irradiated mice at 4, 8, 12, 24 and 48hrs post-irradiation. The mRNA transcriptional changes of 11 genes related to DNA damage and repair were detected using real-time quantitative polymerase chain reaction (RT-PCR). Of the 11 genes examined, CDKN1A (cyclin-dependent kinase inhibitor 1A or p21, Cip1) and ATM (ataxia telangiectasia mutated) expression levels were found to be heavily up- and down-regulated, respectively, with exposure dose increasing at different post-irradiation times. RAD50 (RAD50 homolog), PLK3 (polo-like kinase 3), GADD45A (growth arrest and DNA damage-inducible, alpha), DDB2 (damage-specific DNA-binding protein 2), BBC3 (BCL2-binding component 3) and IER5 (immediate early response 5) gene expression levels were found to undergo significant oscillating changes over a broad dose range of 2-8 Gy at post-exposure time points observed. Three of the genes were found not to change within the observed exposure dose and post-radiation time ranges. The results of this study add to the biodosimetry with biomarker data pool and will be helpful for constructing appropriate gene expression biomarker systems to evaluate radiation exposure doses.

  14. Effects of low dose ibogaine on subjective mood state and psychological performance.

    PubMed

    Forsyth, Bridget; Machado, Liana; Jowett, Tim; Jakobi, Hannah; Garbe, Kira; Winter, Helen; Glue, Paul

    2016-08-02

    Root bark from Tabernanthe iboga has been used traditionally in West Africa as a psychoactive substance in religious rituals. In smaller doses it is reported anecdotally to have stimulant properties. To evaluate the influence of a single 20mg ibogaine dose on psychological variables reflecting subjective mood state and a range of cognitive functions. 21 healthy male volunteers received single 20mg doses of ibogaine after 6 days pretreatment with double-blind paroxetine or placebo. We compared responses to a battery of psychometric tests and subjective mood ratings performed before and 2h after ibogaine dosing, and assessed relationships between changes in test scores and concentrations of active moiety (the sum of molar noribogaine and ibogaine concentrations). Psychological tests were chosen based on responsiveness to opioid and serotonergic ligands. Ibogaine had minimal influence on psychological tests and mood ratings. The ability to selectively ignore distracting spatial information showed some evidence of modulation; however because this effect was limited to the less challenging condition calls into question the reliability of this result. We were unable to identify stimulant effects after single 20mg doses of ibogaine. Future research is needed to confirm whether active moiety concentrations impact selective attention abilities while leaving other cognitive functions and mood state unaffected. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Determination of the effect of different atmospheric composition on the quality of cold stored irradiated apples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okamoto, T.; Harata, J.; Osanai, T.

    1972-03-01

    Jonathan apples were irradiated with /sup 60/Co gamma rays, in doses of 0 (control), 2.5, 5, 7.5, 10, 50, 100 krad (dose rate: 20 krad/hr), and 50krad (dose rate: 100 krad/hr), and stored at 0 deg C in three controlled atmosphere rooms (oxygen 3 to 5%, carbon dioxide below 0.5%; oxygen 21%, carbon dioxide 2 to 2.5%; oxygen 3 to 5%, carbon dioxide 2 to 2.5%) and in a common refrigerated room for 4.5 months. Irradiation of apples with doses of 10 krsd or more seemed to lower slightly their qualities and the same tendency was obseved in CA apples.more » Generally, the effects of CA storage, especially in 3 to 5% O/sub 2/ and 2 to 2.5% CO/sub 2/, on the qualities of apples, i.e., respiration, organoleptic properties, changes in weight, surface color, were stronger than the irradiation effect. However, it seems to be true that the treatment with doses of about 5 krad is not at all inferior to the other treatment. So, as the pretreatment of CA storage of apples the irradiation dose of about 5 krad may be recommended. (auth)« less

  16. Effect of low-dose valsartan on proteinuria in normotensive immunoglobulin A nephropathy with minimal proteinuria: a randomized trial.

    PubMed

    Jo, Young-Il; Na, Ha-Young; Moon, Ju-Young; Han, Sang-Woong; Yang, Dong-Ho; Lee, Sang-Ho; Park, Hyeong-Cheon; Choi, Hoon-Young; Lim, So-Dug; Kie, Jeong-Hae; Lee, Yong-Kyu; Shin, Sug-Kyun

    2016-03-01

    Immunoglobulin A nephropathy (IgAN) is a generally progressive disease, even in patients with favorable prognostic features. In this study, we aimed to investigate the antiproteinuric effect and tolerability of low-dose valsartan (an angiotensin II receptor blocker) therapy in normotensive IgAN patients with minimal proteinuria of less than 0.5 to 1.0 g/day. Normotensive IgAN patients, who had persistent proteinuria with a spot urine protein-to-creatinine ratio of 0.3 to 1.0 mg/mg creatinine, were recruited from five hospitals and randomly assigned to either 40 mg of valsartan as the low-dose group or 80 mg of valsartan as the regular-dose group. Clinical and laboratory data were collected at baseline, and at 4, 8, 12, and 24 weeks after valsartan therapy. Forty-three patients (low-dose group, n = 23; regular-dose group, n = 20) were enrolled in the study. Proteinuria decreased significantly not only in the regular-dose group but also in the low-dose group. The change in urine protein-to-creatinine ratio at week 24 was -41.3% ± 26.1% (p < 0.001) in the regular-dose group and -21.1% ± 45.1% (p = 0.005) in the low-dose group. In the low-dose group, blood pressure was constant throughout the study period, and there was no symptomatic hypotension. In the regular-dose group, blood pressure decreased at weeks 8 and 12. No significant change in glomerular filtration rate, serum creatinine level, or serum potassium level was observed during the study period. Our results suggest that low-dose valsartan can significantly reduce proteinuria without causing any intolerability in normotensive IgAN patients with minimal proteinuria.

  17. Effect of low-dose valsartan on proteinuria in normotensive immunoglobulin A nephropathy with minimal proteinuria: a randomized trial

    PubMed Central

    Jo, Young-Il; Na, Ha-Young; Moon, Ju-Young; Han, Sang-Woong; Yang, Dong-Ho; Lee, Sang-Ho; Park, Hyeong-Cheon; Choi, Hoon-Young; Lim, So-Dug; Kie, Jeong-Hae; Lee, Yong-Kyu; Shin, Sug-Kyun

    2016-01-01

    Background/Aims: Immunoglobulin A nephropathy (IgAN) is a generally progressive disease, even in patients with favorable prognostic features. In this study, we aimed to investigate the antiproteinuric effect and tolerability of low-dose valsartan (an angiotensin II receptor blocker) therapy in normotensive IgAN patients with minimal proteinuria of less than 0.5 to 1.0 g/day. Methods: Normotensive IgAN patients, who had persistent proteinuria with a spot urine protein-to-creatinine ratio of 0.3 to 1.0 mg/mg creatinine, were recruited from five hospitals and randomly assigned to either 40 mg of valsartan as the low-dose group or 80 mg of valsartan as the regular-dose group. Clinical and laboratory data were collected at baseline, and at 4, 8, 12, and 24 weeks after valsartan therapy. Results: Forty-three patients (low-dose group, n = 23; regular-dose group, n = 20) were enrolled in the study. Proteinuria decreased significantly not only in the regular-dose group but also in the low-dose group. The change in urine protein-to-creatinine ratio at week 24 was −41.3% ± 26.1% (p < 0.001) in the regular-dose group and −21.1% ± 45.1% (p = 0.005) in the low-dose group. In the low-dose group, blood pressure was constant throughout the study period, and there was no symptomatic hypotension. In the regular-dose group, blood pressure decreased at weeks 8 and 12. No significant change in glomerular filtration rate, serum creatinine level, or serum potassium level was observed during the study period. Conclusions: Our results suggest that low-dose valsartan can significantly reduce proteinuria without causing any intolerability in normotensive IgAN patients with minimal proteinuria. PMID:26874511

  18. Quantification of rat retinal growth and vascular population changes after single and split doses of proton irradiation: translational study using stereology methods

    NASA Technical Reports Server (NTRS)

    Mao, Xiao W.; Archambeau, John O.; Kubinova, Lucie; Boyle, Soames; Petersen, Georgia; Grove, Roger; Nelson, G. A. (Principal Investigator)

    2003-01-01

    This study quantified architectural and population changes in the rat retinal vasculature after proton irradiation using stereology. A 100 MeV conformal proton beam delivered 8, 14, 20 and 28 Gy as single and split doses to the whole eye. The vascular networks were prepared from retinal digests. Stereological methods were used to obtain the area of the retina and unbiased estimates of microvessel/artery/vein endothelial, pericyte and smooth muscle population, and vessel length. The retinal area increased progressively in the unirradiated, age-matched controls and in the retinas irradiated with 8 and 14 Gy, indicating uniform progressive retinal growth. No growth occurred after 20 and 28 Gy. Regression analysis of total endothelial cell number in all vessels (arteries, veins and capillaries) after irradiation documented a progressive time- and dose-dependent cell loss occurring over 15 to 24 months. The difference from controls was significant (P<0.01) after 28 Gy given in single and split doses and after 20 Gy given as a split dose (P<0.05). Total vessel length in microvessel was significantly shortened at 20 and 28 Gy compared to that of controls (P<0.05). No evident dose recovery was observed in the endothelial populations after split doses. At 10 Gy, the rate of endothelial cell loss, a dose parameter used to characterize the time- and dose-dependent loss of the endothelial population, was doubled.

  19. Increased intracranial pressure in mini-pigs exposed to simulated solar particle event radiation

    NASA Astrophysics Data System (ADS)

    Sanzari, Jenine K.; Muehlmatt, Amy; Savage, Alexandria; Lin, Liyong; Kennedy, Ann R.

    2014-02-01

    Changes in intracranial pressure (ICP) during space flight have stimulated an area of research in space medicine. It is widely speculated that elevations in ICP contribute to structural and functional ocular changes, including deterioration in vision, which is also observed during space flight. The aim of this study was to investigate changes in opening pressure (OP) occurring as a result of ionizing radiation exposure (at doses and dose-rates relevant to solar particle event radiation). We used a large animal model, the Yucatan mini-pig, and were able to obtain measurements over a 90 day period. This is the first investigation to show long term recordings of ICP in a large animal model without an invasive craniotomy procedure. Further, this is the first investigation reporting increased ICP after radiation exposure.

  20. Impact of the Norepinephrine Prodrug Droxidopa on the QTc Interval in Healthy Individuals.

    PubMed

    White, William B; Hewitt, L Arthur; Mehdirad, Ali A

    2018-03-01

    A double-blind, 4-period crossover study (NCT01327066) was conducted to assess the effect of the novel norepinephrine prodrug droxidopa on the QT interval in in healthy subjects. Subjects were randomized to receive a single dose of droxidopa 600 mg (maximal dose) and 2000 mg (supratherapeutic dose) compared with the positive control, moxifloxacin 400 mg, and placebo, each separated by a 3-day washout period. Patients were monitored by continuous Holter monitoring, and electrocardiograms (ECGs) were extracted 0.5-23 hours after dosing. Blood samples for pharmacokinetic analysis were collected before dosing and after ECG data collection. The primary end point was the time-matched placebo-adjusted change from baseline in the individually corrected QT (QTcI). The time-averaged QTcI mean placebo-corrected changes from baseline for droxidopa 600 and 2000 mg were 0.1 milliseconds (90%CI, -0.9 to 1.0 milliseconds) and 0.3 milliseconds (90%CI, -0.6 to 1.3 milliseconds), respectively, and 9 milliseconds (90%CI, 8.4-10.3 milliseconds) for moxifloxacin. This study found no effect of either dose of droxidopa on cardiac repolarization using QTcI. Analysis of the pharmacokinetic/pharmacodynamic relationship and cardiac repolarization showed no association with droxidopa exposure. There were no clinically relevant effects of droxidopa on heart rate, atrioventricular conduction, or cardiac depolarization identified. No morphologic ECG changes were observed. © 2017 The Authors. Clinical Pharmacology in Drug Development Published by Wiley Periodicals, Inc. on behalf of American College of Clinical Pharmacology.

  1. Impact of the Norepinephrine Prodrug Droxidopa on the QTc Interval in Healthy Individuals

    PubMed Central

    Hewitt, L. Arthur; Mehdirad, Ali A.

    2017-01-01

    Abstract A double‐blind, 4‐period crossover study (NCT01327066) was conducted to assess the effect of the novel norepinephrine prodrug droxidopa on the QT interval in in healthy subjects. Subjects were randomized to receive a single dose of droxidopa 600 mg (maximal dose) and 2000 mg (supratherapeutic dose) compared with the positive control, moxifloxacin 400 mg, and placebo, each separated by a 3‐day washout period. Patients were monitored by continuous Holter monitoring, and electrocardiograms (ECGs) were extracted 0.5–23 hours after dosing. Blood samples for pharmacokinetic analysis were collected before dosing and after ECG data collection. The primary end point was the time‐matched placebo‐adjusted change from baseline in the individually corrected QT (QTcI). The time‐averaged QTcI mean placebo‐corrected changes from baseline for droxidopa 600 and 2000 mg were 0.1 milliseconds (90%CI, ‐0.9 to 1.0 milliseconds) and 0.3 milliseconds (90%CI, ‐0.6 to 1.3 milliseconds), respectively, and 9 milliseconds (90%CI, 8.4–10.3 milliseconds) for moxifloxacin. This study found no effect of either dose of droxidopa on cardiac repolarization using QTcI. Analysis of the pharmacokinetic/pharmacodynamic relationship and cardiac repolarization showed no association with droxidopa exposure. There were no clinically relevant effects of droxidopa on heart rate, atrioventricular conduction, or cardiac depolarization identified. No morphologic ECG changes were observed. PMID:29024579

  2. Dose estimates for the 1104 m APS storage ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moe, H.J.

    1989-06-01

    The estimated dose equivalent rates outside the shielded storage ring, and the estimated annual dose equivalent to members of the public due to direct radiation and skyshine from the ring, have been recalculated. The previous estimates found in LS-84 (MOE 87) and cited in the 1987 Conceptual Design Report of the APS (ANL 87) required revision because of changes in the ring circumference and in the proposed location of the ring with respect to the nearest site boundary. The values assumed for the neutron quality factors were also overestimated (by a factor of 2) in the previous computation, and themore » correct values have been used for this estimate. The methodology used to compute dose and dose rate from the storage ring is the same as that used in LS-90 (MOE 87a). The calculations assumed 80 cm thick walls of ordinary concrete (or the shielding equivalent of this) and a roof thickness of 1 meter of ordinary concrete. The circumference of the ring was increased to 1,104 m, and the closest distance to the boundary was taken as 140 m. The recalculation of the skyshine component used the same methodology as that used in LS-84.« less

  3. Shockwave treatment for medial tibial stress syndrome: A randomized double blind sham-controlled pilot trial.

    PubMed

    Newman, Phil; Waddington, Gordon; Adams, Roger

    2017-03-01

    Up to 35% of runners develop medial tibial stress syndrome (MTSS) which often results in lengthy disruption to training and sometimes affects daily activities. There is currently no high quality evidence to support any particular intervention for MTSS. This study aims to investigate the effect of shockwave therapy for MTSS. A randomized, sham-controlled, pilot trial in a university-based health clinic including 28 active adults with MTSS. Intervention included standard dose shockwave therapy for the experimental group versus sham dose for the control group, delivered during Week 1-3, 5 and 9. Main outcome measures were pain measured during bone and muscle pressure as well as during running using a numerical rating scale (0-10) and running was measured as pain-limited distance (m), at Week 1 (baseline) and Week 10 (post-intervention). Self-perception of change was measured using the Global Rating of Change Scale (-7 to +7) at Week 10 (post-intervention). Pain (palpation) was reduced in the experimental group by 1.1 out of 10.0 (95% CI -2.3 to 0.0) less than the control group. There were no other statistically significant differences between the groups. Standard dose shockwave therapy is not more effective than sham dose at improving pain or running distance in MTSS. However, the sham dose may have had a clinical effect. Further investigation including a no intervention control is warranted to evaluate the effect of shockwave therapy in the management of MTSS. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  4. Photothermal damage is correlated to the delivery rate of time-integrated temperature

    NASA Astrophysics Data System (ADS)

    Denton, Michael L.; Noojin, Gary D.; Gamboa, B. Giovanna; Ahmed, Elharith M.; Rockwell, Benjamin A.

    2016-03-01

    Photothermal damage rate processes in biological tissues are usually characterized by a kinetics approach. This stems from experimental data that show how the transformation of a specified biological property of cells or biomolecule (plating efficiency for viability, change in birefringence, tensile strength, etc.) is dependent upon both time and temperature. However, kinetic methods require determination of kinetic rate constants and knowledge of substrate or product concentrations during the reaction. To better understand photothermal damage processes we have identified temperature histories of cultured retinal cells receiving minimum lethal thermal doses for a variety of laser and culture parameters. These "threshold" temperature histories are of interest because they inherently contain information regarding the fundamental thermal dose requirements for damage in individual cells. We introduce the notion of time-integrated temperature (Tint) as an accumulated thermal dose (ATD) with units of °C s. Damaging photothermal exposure raises the rate of ATD accumulation from that of the ambient (e.g. 37 °C) to one that correlates with cell death (e.g. 52 °C). The degree of rapid increase in ATD (ΔATD) during photothermal exposure depends strongly on the laser exposure duration and the ambient temperature.

  5. Randomized controlled trial of a dose consolidation program.

    PubMed

    Delate, Thomas; Fairman, Kathleen A; Carey, Shelly M; Motheral, Brenda R

    2004-01-01

    To evaluate the effectiveness and financial impact of a drug dose consolidation (optimization) program using letter intervention. This pilot program in a large, mid-Atlantic health plan utilized a randomized controlled trial research design. A review of adjudicated pharmacy claims records was performed monthly for 3 consecutive months from November 2002 through February 2003 to identify inefficient (i.e., >once-daily) regimens for any one of 68 dosage strengths of 37 single-source maintenance drugs with once-daily dosing recommendations. Prescribers who had prescribed one or more inefficient regimens were identified and randomized to one of the 2 intervention arms or a control arm. Prescribers in both intervention arms were sent personalized letters with information on their patients. inefficient regimens and suggested dose consolidation options. Patients of prescribers in one intervention arm received a complementary, patient-oriented letter. Pharmacy claims for patients in all arms were examined at 180 days after the date of the letter mailing for conversion to an efficient (once-daily) regimen. Financial modeling analysis calculated net savings as changes in pharmacy expenditures minus administrative costs. A total of 2,614 inefficient regimens, representing 6.7% of claims for the targeted medications, were identified. The rate of consolidation to a suggested dosing option was lower for the Physician Letter arm (7.3%) than for the Physician/Member Letter arm (10.2%) (P = 0.046). Both intervention arms had higher consolidation rates than the Control arm (3.9%) (P = 0.018 and P = 0.000, respectively.). Approximately 30% of the regimens in each study arm were never refilled after being targeted. Financial modeling indicated that a dose consolidation intervention could save 0.03 dollars to 0.07 dollars per member per month (PMPM) in 2003 dollars with full medication compliance but only 0.02 dollars to 0.03 dollars PMPM when savings were calculated with realistic, partial compliance rates. Subanalyses performed at the drug therapy class level revealed few opportunities to justify implementing a dose consolidation program. After taking into consideration program administrative costs, high rates of refill discontinuation, and dose consolidation that occurs naturally without intervention, the results indicated that a letter-based dose consolidation program did not appreciably decrease pharmacy expenditures.

  6. The Utility of Low-Dose Aripiprazole for the Treatment of Bipolar II and Bipolar NOS Depression.

    PubMed

    Kelly, Tammas; Lieberman, Daniel Z

    2017-02-01

    Despite initial reports of efficacy in bipolar depression, multicenter trials did not show aripiprazole to be better than placebo, possibly because the doses used were too high, leading to lower efficacy and high dropout rates. This study evaluated the effects of low-dose aripiprazole. Extensive clinical experience has suggested that doses beyond 5 mg are rarely efficacious. Data were gathered from patients with bipolar II or bipolar not otherwise specified depression using a retrospective chart review. Efficacy was assessed with the Clinical Global Impression-Improvement score. Patients who had at least 2 trials of aripiprazole were included in a retrospective off-on-off-on experimental design. All patients were on other medications when aripiprazole was started. Patients were treated with doses of 1 to 5 mg. On average, patients were rated improved or very much improved compared with baseline. Sixteen of 211 patients worsened or experienced no change. Forty-four patients (21%) discontinued due to adverse effects. The group of patients who underwent off-on-off-on trials experienced statistically significant improvement when they started and restarted aripiprazole, and statistically significant worsening when they discontinued it. When treating bipolar II or bipolar not otherwise specified depression, low doses of aripiprazole, 5 mg or less, may be more effective and better tolerated than higher ones. Clinicians should start treatment with a very low dose and give patients time to respond.

  7. An open treatment trial of duloxetine in elderly patients with dysthymic disorder.

    PubMed

    Kerner, Nancy; D'Antonio, Kristina; Pelton, Gregory H; Salcedo, Elianny; Ferrar, Jennifer; Roose, Steven P; Devanand, Dp

    2014-05-08

    We evaluated the efficacy and side effects of the selective serotonin and norepinephrine reuptake inhibitor antidepressant duloxetine in older adults with dysthymic disorder. Patients ≥ 60 years old with dysthymic disorder received flexible dose duloxetine 20-120 mg daily in an open-label 12-week trial. The main outcomes were change from baseline to 12 weeks in 24-item Hamilton Depression Rating Scale scores and Treatment Emergent Symptoms Scale scores. Response required ≥ 50% decline in Hamilton Depression Rating Scale scores with a Clinical Global Impression of much improved or better, and remission required final Hamilton Depression Rating Scale ≤ 6. Intent-to-treat analyses were conducted with the last observation carried forward. In 30 patients, the mean age was 70.7 (standard deviation (SD) = 7.6) years and 56.7% were female. In intent-to-treat analyses, there were 16 responders (53.3%) and 10 remitters (33.3%). Of these, 19 patients completed the trial. The mean maximum dose was 76.3 mg (SD = 38.5) in the total sample and 101 mg (SD = 17.9) in completers. In the total sample, the mean final dose was 51 mg (SD = 27.2) and correlated significantly with decline in Hamilton Depression Rating Scale ( p < .03); decline in Hamilton Depression Rating Scale correlated significantly with decline in Treatment Emergent Symptoms Scale ( p < .001). Daily doses above 60 mg were associated with greater improvement and well tolerated. This result was partly confounded by early dropouts having received low doses. Demographic and medical comorbidities, including cardiac disease and hypertension, were not related to response. Somatic side effects were common prior to duloxetine treatment and improved rather than worsened with duloxetine. There were no serious adverse events. Duloxetine at relatively high doses showed moderate efficacy in elderly patients with dysthymic disorder and was well tolerated in successful completers. Reduced somatic symptoms were associated with improvement in depressive symptoms. A systematic placebo-controlled trial of duloxetine in older patients with dysthymic disorder may be warranted.

  8. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    PubMed

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100,000 members per quarter [95% CI, -0.01 to 0.53]). Opioid dispensing and prescription opioid overdoses decreased substantially after 2 major changes in the pharmaceutical market in late 2010. Pharmaceutical market interventions may have value in combatting the prescription opioid overdose epidemic, but heroin overdose rates continue to increase. Complementary strategies to identify and treat opioid abuse and addiction are urgently needed.

  9. WISE-2005: Adrenergic Responses Before and After 60 Days of 6 Degree Head-Down Bed-Rest in Women

    NASA Technical Reports Server (NTRS)

    Edgell, H.; Dyson, K.; Shoemaker, J. K.; Custaud, M. A.; Arbeille, Ph.; Greaves, D.; Hughson, R. L.; Hughson, R. L.

    2006-01-01

    Sixteen women who participated in the WISE-2005 headdown bed rest (HDBR) were studied before and on day 56 of bed rest to test the hypothesis that chronic changes in circulating norepinephrine (NOR) would change the response to adrenergic receptor agonists. Five minute infusions of 2 doses of isoproterenol (ISO), and 2 doses of NOR were administered while heart rate (HR), mean arterial pressure (MAP) and total peripheral resistance (TPR) were measured. Before HDBR, the higher dose of ISO increased HR by 13 beats/min (P

  10. [Antitumor effect of baicalin on rat brain glioma].

    PubMed

    Hu, Yong-zhen; Wang, Dian-hong; Luan, Yu; Gong, Hai-dong

    2013-01-01

    To investigate the therapeutic mechanism of baicalin on rat brain glioma. Deep brain glioma models were established by injection of glioma cell line C6 cells into the brain of Wistar rats. The rats at 7 days after modeling were randomly divided into tumor control group (0.9% NaCl solution 30 mg×kg(-1)×d(-1) gavage)and experimental groups. The experimental rats was divided into 3 groups: low dose group (50 mg×kg(-1)×d(-1)), middle dose group (100 mg×kg(-1)×d(-1)) and high dose group (200 mg×kg(-1)×d(-1)), given the baicalin by gavage. Pathological and electron microscopic changes were observed. The expressions of p53 and Bcl-2 were determined by immunohistochemistry, and the changes of MRI, the average survival time and body weight of the rats in each group after treatments were analyzed. Compared with the control group, the tumor diameter and volume of high dose group rats before sacrifice were significantly reduced (P < 0.01), and the survival time was significantly prolonged (P < 0.01). Immunohistochemistry revealed strong positive expression rate of mutant p53 (84.47 ± 3.74)% and moderately positive rate (47.28 ± 2.38)% in the control group, significantly higher than that in the negative group (12.91 ± 1.07)% (P < 0.01). The positive rate of mutant p53 of the high dose group was (46.42 ± 2.19)%, significantly lower than that of the control group (84.47 ± 3.74)% (P < 0.01). The expression rate of Bcl-2 in the control group was strongly positive (86.51 ± 4.17)% and moderate positive (48.19 ± 2.11)%, significantly higher than that of the negative group (10.36 ± 1.43)% (P < 0.01). Electron microscopy revealed that baicalin caused damages of the cell nuclei and organelles in the gliomas. Baicalin has significant inhibitory effect on glioma in vivo, and its mechanism may be related to cell apoptosis induced by down-regulated expression of mutant p53, but not related with Bcl-2 expression.

  11. Dosimetric effects of Onyx embolization on Gamma Knife arteriovenous malformation dose distributions.

    PubMed

    Schlesinger, David J; Nordström, Håkan; Lundin, Anders; Xu, Zhiyuan; Sheehan, Jason P

    2016-12-01

    OBJECTIVE Patients with arteriovenous malformations (AVMs) treated with Gamma Knife radiosurgery (GKRS) subsequent to embolization suffer from elevated local failure rates and differences in adverse radiation effects. Onyx is a common embolic material for AVMs. Onyx is formulated with tantalum, a high atomic number (Z = 73) element that has been investigated as a source of dosimetric uncertainty contributing to the less favorable clinical results. However, prior studies have not modeled the complicated anatomical and beam geometries characteristic of GKRS. This study investigated the magnitude of dose perturbation that can occur due to Onyx embolization using clinically realistic anatomical and Gamma Knife beam models. METHODS Leksell GammaPlan (LGP) was used to segment the AVM nidus and areas of Onyx from postcontrast stereotactic MRI for 7 patients treated with GKRS postembolization. The resulting contours, skull surface, and clinically selected dose distributions were exported from LGP in DICOM-RT (Digital Imaging and Communications in Medicine-radiotherapy) format. Isocenter locations and dwell times were recorded from the LGP database. Contours were converted into 3D mesh representations using commercial and in-house mesh-editing software. The resulting data were imported into a Monte Carlo (MC) dose calculation engine (Pegasos, Elekta Instruments AB) with a beam geometry for the Gamma Knife Perfexion. The MC-predicted dose distributions were calculated with Onyx assigned manufacturer-reported physical constants (MC-Onyx), and then compared with corresponding distributions in which Onyx was reassigned constants for water (MC-water). Differences in dose metrics were determined, including minimum, maximum, and mean dose to the AVM nidus; selectivity index; and target coverage. Combined differences in dose magnitude and distance to agreement were calculated as 3D Gamma analysis passing rates using tolerance criteria of 0.5%/0.5 mm, 1.0%/1.0 mm, and 3.0%/3.0 mm. RESULTS Overall, the mean percentage differences in dose metrics for MC-Onyx relative to MC-water were as follows; all data are reported as mean (SD): minimum dose to AVM = -0.7% (1.4%), mean dose to AVM = 0.1% (0.2%), maximum dose to AVM = 2.9% (5.0%), selectivity = 0.1% (0.2%), and coverage = -0.0% (0.2%). The mean percentage of voxels passing at each Gamma tolerance were as follows: 99.7% (0.1%) for 3.0%/3.0 mm, 98.2% (0.7%) for 1.0%/1.0 mm, and 52.1% (4.4%) for 0.5%/0.5 mm. CONCLUSIONS Onyx embolization appears to have a detectable effect on the delivered dose distribution. However, the small changes in dose metrics and high Gamma passing rates at 1.0%/1.0 mm tolerance suggest that these changes are unlikely to be clinically significant. Additional sources of delivery and biological uncertainty should be investigated to determine the root cause of the observed less favorable postembolization GKRS outcomes.

  12. High-Dose Opioid Prescribing and Opioid-Related Hospitalization: A Population-Based Study.

    PubMed

    Fernandes, Kimberly; Martins, Diana; Juurlink, David; Mamdani, Muhammad; Paterson, J Michael; Spooner, Luke; Singh, Samantha; Gomes, Tara

    2016-01-01

    To examine the impact of national clinical practice guidelines and provincial drug policy interventions on prevalence of high-dose opioid prescribing and rates of hospitalization for opioid toxicity. Interventional time-series analysis. Ontario, Canada, from 2003 to 2014. Ontario Drug Benefit (ODB) beneficiaries aged 15 to 64 years from 2003 to 2014. Publication of Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain (May 2010) and implementation of Ontario's Narcotics Safety and Awareness Act (NSAA; November 2011). Three outcomes were explored: the rate of opioid use among ODB beneficiaries, the prevalence of opioid prescriptions exceeding 200 mg and 400 mg morphine equivalents per day, and rates of opioid-related emergency department visits and hospital admissions. Over the 12 year study period, the rate of opioid use declined 15.2%, from 2764 to 2342 users per 10,000 ODB eligible persons. The rate of opioid use was significantly impacted by the Canadian clinical practice guidelines (p-value = .03) which led to a decline in use, but no impact was observed by the enactment of the NSAA (p-value = .43). Among opioid users, the prevalence of high-dose prescribing doubled (from 4.2% to 8.7%) over the study period. By 2014, 40.9% of recipients of long-acting opioids exceeded daily doses of 200 mg morphine or equivalent, including 55.8% of long-acting oxycodone users and 76.3% of transdermal fentanyl users. Moreover, in the last period, 18.7% of long-acting opioid users exceeded daily doses of 400 mg morphine or equivalent. Rates of opioid-related emergency department visits and hospital admissions increased 55.0% over the study period from 9.0 to 14.0 per 10,000 ODB beneficiaries from 2003 to 2013. This rate was not significantly impacted by the Canadian clinical practice guidelines (p-value = .68) or enactment of the NSAA (p-value = .59). Although the Canadian clinical practice guidelines for use of opioids in chronic non-cancer pain led to a decline in opioid prescribing rates among ODB beneficiaries these guidelines and subsequent Ontario legislation did not result in a significant change in rates of opioid-related hospitalizations. Given the prevalence of high dose opioid prescribing in this population, this suggests that improved strategies and programs for the safe prescribing of long-acting opioids are needed.

  13. In-flight radiation measurements on STS-60

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Golightly, M. J.; Konradi, A.; Atwell, W.; Kern, J. W.; Cash, B.; Benton, E. V.; Frank, A. L.; Sanner, D.; Keegan, R. P.; hide

    1996-01-01

    A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

  14. Radiation dose-rate meter using an energy-sensitive counter

    DOEpatents

    Kopp, Manfred K.

    1988-01-01

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  15. Reductions in carotid chemoreceptor activity with low-dose dopamine improves baroreflex control of heart rate during hypoxia in humans.

    PubMed

    Mozer, Michael T; Holbein, Walter W; Joyner, Michael J; Curry, Timothy B; Limberg, Jacqueline K

    2016-07-01

    The purpose of the present investigation was to examine the contribution of the carotid body chemoreceptors to changes in baroreflex control of heart rate with exposure to hypoxia. We hypothesized spontaneous cardiac baroreflex sensitivity (scBRS) would be reduced with hypoxia and this effect would be blunted when carotid chemoreceptor activity was reduced with low-dose dopamine. Fifteen healthy adults (11 M/4 F) completed two visits randomized to intravenous dopamine or placebo (saline). On each visit, subjects were exposed to 5-min normoxia (~99% SpO2), followed by 5-min hypoxia (~84% SpO2). Blood pressure (intra-arterial catheter) and heart rate (ECG) were measured continuously and scBRS was assessed by spectrum and sequence methodologies. scBRS was reduced with hypoxia (P < 0.01). Using the spectrum analysis approach, the fall in scBRS with hypoxia was attenuated with infusion of low-dose dopamine (P < 0.01). The decrease in baroreflex sensitivity to rising pressures (scBRS "up-up") was also attenuated with low-dose dopamine (P < 0.05). However, dopamine did not attenuate the decrease in baroreflex sensitivity to falling pressures (scBRS "down-down"; P > 0.05). Present findings are consistent with a reduction in scBRS with systemic hypoxia. Furthermore, we show this effect is partially mediated by the carotid body chemoreceptors, given the fall in scBRS is attenuated when activity of the chemoreceptors is reduced with low-dose dopamine. However, the improvement in scBRS with dopamine appears to be specific to rising blood pressures. These results may have important implications for impairments in baroreflex function common in disease states of acute and/or chronic hypoxemia, as well as the experimental use of dopamine to assess such changes. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  16. The Effect of Different Doses of X-Irradiation on the Corticosteroid Secretion in Rabbits USSR.

    DTIC Science & Technology

    1960-06-30

    Tuul1 in Patolog ;. Fi2iol. 1 Eksper, Terapiya (Patho- logical Physiology and Experimental Therapy)» Vol. IV, No. 1, I960» p&gss 24-28. — Fron the... relationship of the changes in the nature of secretion of corticosteroids observed after irradiation to the degree of radiation injury we nade an...studying the relationship of the rate of secretion of the various cortical hormones to the magnitude of the dose received by the rabbits

  17. The susceptibility of TaO x-based memristors to high dose rate ionizing radiation and total ionizing dose

    DOE PAGES

    McLain, Michael Lee; Sheridan, Timothy J.; Hjalmarson, Harold Paul; ...

    2014-11-11

    This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaO x) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×10 7 rad(Si)/s to 4.7 ×10 8 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×10 8 rad(Si)/s. This is the first dose rate study on any type ofmore » memristive memory technology. In addition to assessing the tolerance of TaO x memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.« less

  18. Effect of gamma irradiation on high temperature hardness of low-density polyethylene

    NASA Astrophysics Data System (ADS)

    Chen, Pei-Yun; Yang, Fuqian; Lee, Sanboh

    2015-11-01

    Gamma irradiation can cause the change of microstructure and molecular structure of polymer, resulting in the change of mechanical properties of polymers. Using the hardness measurement, the effect of gamma irradiation on the high temperature hardness of low-density polyethylene (LDPE) was investigated. The gamma irradiation caused the increase in the melting point, the enthalpy of fusion, and the portion of crystallinity of LDPE. The Vickers hardness of the irradiated LDPE increases with increasing the irradiation dose, annealing temperature, and annealing time. The activation energy for the rate process controlling the reaction between defects linearly decreases with the irradiation dose. The process controlling the hardness evolution in LDPE is endothermic because LDPE is semi-crystalline.

  19. Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid

    PubMed Central

    Bache, Steven; Malcolm, Javian; Adamovics, John; Oldham, Mark

    2016-01-01

    Telecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS—Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and the use of a ‘solid tank’ (which reduces noise, and the volume of refractively matched fluid from 1ltr to 10cc). The efficacy of DFOS was evaluated by direct comparison against commissioned scanners in our lab. Measured dose distributions from all systems were compared against the predicted dose distributions from a commissioned treatment planning system (TPS). Three treatment plans were investigated including a simple four-field box treatment, a multiple small field delivery, and a complex IMRT treatment. Dosimeters were imaged within 2h post irradiation, using consistent scanning techniques (360 projections acquired at 1 degree intervals, reconstruction at 2mm). DFOS efficacy was evaluated through inspection of dose line-profiles, and 2D and 3D dose and gamma maps. DFOS/TPS gamma pass rates with 3%/3mm dose difference/distance-to-agreement criteria ranged from 89.3% to 92.2%, compared to from 95.6% to 99.0% obtained with the commissioned system. The 3D gamma pass rate between the commissioned system and DFOS was 98.2%. The typical noise rates in DFOS reconstructions were up to 3%, compared to under 2% for the commissioned system. In conclusion, while the introduction of a solid tank proved advantageous with regards to cost and convenience, further work is required to improve the image quality and dose reconstruction accuracy of the new DFOS optical-CT system. PMID:27019460

  20. Optical-CT 3D Dosimetry Using Fresnel Lenses with Minimal Refractive-Index Matching Fluid.

    PubMed

    Bache, Steven; Malcolm, Javian; Adamovics, John; Oldham, Mark

    2016-01-01

    Telecentric optical computed tomography (optical-CT) is a state-of-the-art method for visualizing and quantifying 3-dimensional dose distributions in radiochromic dosimeters. In this work a prototype telecentric system (DFOS-Duke Fresnel Optical-CT Scanner) is evaluated which incorporates two substantial design changes: the use of Fresnel lenses (reducing lens costs from $10-30K t0 $1-3K) and the use of a 'solid tank' (which reduces noise, and the volume of refractively matched fluid from 1 ltr to 10 cc). The efficacy of DFOS was evaluated by direct comparison against commissioned scanners in our lab. Measured dose distributions from all systems were compared against the predicted dose distributions from a commissioned treatment planning system (TPS). Three treatment plans were investigated including a simple four-field box treatment, a multiple small field delivery, and a complex IMRT treatment. Dosimeters were imaged within 2 h post irradiation, using consistent scanning techniques (360 projections acquired at 1 degree intervals, reconstruction at 2mm). DFOS efficacy was evaluated through inspection of dose line-profiles, and 2D and 3D dose and gamma maps. DFOS/TPS gamma pass rates with 3%/3mm dose difference/distance-to-agreement criteria ranged from 89.3% to 92.2%, compared to from 95.6% to 99.0% obtained with the commissioned system. The 3D gamma pass rate between the commissioned system and DFOS was 98.2%. The typical noise rates in DFOS reconstructions were up to 3%, compared to under 2% for the commissioned system. In conclusion, while the introduction of a solid tank proved advantageous with regards to cost and convenience, further work is required to improve the image quality and dose reconstruction accuracy of the new DFOS optical-CT system.

  1. Comparison of U.S. Environmental Protection Agency's CAP88 PC Versions 3.0 and 4.0.

    PubMed

    Jannik, Tim; Farfan, Eduardo B; Dixon, Ken; Newton, Joseph; Sailors, Christopher; Johnson, Levi; Moore, Kelsey; Stahman, Richard

    2015-08-01

    The Savannah River National Laboratory (SRNL) with the assistance of Georgia Regents University, completed a comparison of the U.S. Environmental Protection Agency's (U.S. EPA) environmental dosimetry code CAP88 PC V3.0 with the recently developed V4.0. CAP88 is a set of computer programs and databases used for estimation of dose and risk from radionuclide emissions to air. At the U.S. Department of Energy's Savannah River Site, CAP88 is used by SRNL for determining compliance with U.S. EPA's National Emission Standards for Hazardous Air Pollutants (40 CFR 61, Subpart H) regulations. Using standardized input parameters, individual runs were conducted for each radionuclide within its corresponding database. Some radioactive decay constants, human usage parameters, and dose coefficients changed between the two versions, directly causing a proportional change in the total effective dose. A detailed summary for select radionuclides of concern at the Savannah River Site (60Co, 137Cs, 3H, 129I, 239Pu, and 90Sr) is provided. In general, the total effective doses will decrease for alpha/beta emitters because of reduced inhalation and ingestion rates in V4.0. However, for gamma emitters, such as 60Co and 137Cs, the total effective doses will increase because of changes U.S. EPA made in the external ground shine calculations.

  2. Heart rate changes during electroconvulsive therapy

    PubMed Central

    2013-01-01

    Background This observational study documented heart rate over the entire course of electrically induced seizures and aimed to evaluate the effects of stimulus electrode placement, patients' age, stimulus dose, and additional predictors. Method In 119 consecutive patients with 64 right unilateral (RUL) and 55 bifrontal (BF) electroconvulsive treatments, heart rate graphs based on beat-to-beat measurements were plotted up to durations of 130 s. Results In RUL stimulation, the initial drop in heart rate lasted for 12.5 ± 2.6 s (mean ± standard deviation). This depended on stimulus train duration, age, and baseline heart rate. In seizures induced with BF electrode placement, a sympathetic response was observed within the first few seconds of the stimulation phase (median 3.5 s). This was also the case with subconvulsive stimulations. The mean peak heart rate in all 119 treatments amounted to 135 ± 20 bpm and depended on baseline heart rate and seizure duration; electrode placement, charge dose, and age were insignificant in regression analysis. A marked decline in heart rate in connection with seizure cessation occurred in 71% of treatments. Conclusions A significant independent effect of stimulus electrode positioning on cardiac action was evident only in the initial phase of the seizures. Electrical stimulation rather than the seizure causes the initial heart rate increase in BF treatments. The data reveal no rationale for setting the stimulus doses as a function of intraictal peak heart rates (‘benchmark method’). The marked decline in heart rate at the end of most seizures is probably mediated by a baroreceptor reflex. PMID:23764036

  3. Advanced water remediation from ofloxacin by ionizing radiation

    NASA Astrophysics Data System (ADS)

    Esposito, Biagio R.; Capobianco, Massimo L.; Martelli, Alessandro; Navacchia, Maria Luisa; Pretali, Luca; Saracino, Michela; Zanelli, Alberto; Emmi, Salvatore S.

    2017-12-01

    The performances of remediation processes initiated by ionizing radiation on ofloxacin are investigated in ambient conditions. The effectiveness of the decomposition of ofloxacin has been assessed both by γ-rays and electron beam in various aqueous solutions differentiated by the dissolved gases (Air or oxygen saturated) and H2O2. By HPLC it is shown that ofloxacin is removed according to a first order process vs. dose in any system. O2 accelerates the decomposition rate, while H2O2 does not seem to enhance any oxidation effect. The simultaneous oxidative-reductive treatment (no additive) demonstrated to have better mineralizing performances than the fully oxidative one (H2O2 present). Mineralization by γ results to be more efficient than by EB. The Total Organic Carbon decrease was investigated in dependence of dose and of the •OH production rate. The latter parameter was changed over 7 orders of magnitude by controlling dose rate and/or by adding H2O2. A steep increase of acidity remarks the phases of fluorine-carbon bond break.

  4. Regeneration of Murine Hair Follicles is Inhibited by Low-Dose-Rate Gamma Irradiation.

    PubMed

    Sugaya, Kimihiko; Hirobe, Tomohisa; Ishihara, Yoshie; Inoue, Sonoe

    2016-10-01

    To determine whether the effects of low-dose-rate gamma (γ) irradiation are identifiable in the regeneration of murine hair follicles, we irradiated whole bodies of C57BL/10JHir mice in the first telogen phase of the hair cycle with 137 Cs γ-rays. The mice were examined for effects on hair follicles, including number, morphology, and pigmentation in the second anagen phase. Effects of γ-radiation on melanocyte stem cells were also investigated by the indirect immunolabeling of tyrosinase-related protein 2 (TRP2). Irradiated skin showed a decrease in hair follicle density and the induction of curved hair follicles along with the presence of white hairs and hypopigmented hair bulbs. There was a small, but not significant, change in the number of TRP2-positive melanocyte stem cells in the hair bulge region of the irradiated skin. These results suggest that low-dose rate γ-irradiation does not deplete melanocyte stem cells, but can damage stem cells and progenitors for both keratinocytes and melanocytes, thereby affecting the structure and pigmentation of regenerated hair follicles in the 2 nd anagen phase.

  5. Effect of low-dose, short-duration creatine supplementation on anaerobic exercise performance.

    PubMed

    Hoffman, Jay R; Stout, Jeffrey R; Falvo, Michael J; Kang, Jie; Ratamess, Nicholas A

    2005-05-01

    To examine the efficacy of a low-dose, short-duration creatine monohydrate supplement, 40 physically active men were randomly assigned to either a placebo or creatine supplementation group (6 g of creatine monohydrate per day). Testing occurred before and at the end of 6 days of supplementation. During each testing session, subjects performed three 15-second Wingate anaerobic power tests. No significant (p > 0.05) group or time differences were observed in body mass, peak power, mean power, or total work. In addition, no significant (p > 0.05) differences were observed in peak power, mean power, or total work. However, the change in the rate of fatigue of total work was significantly (p < 0.05) lower in the creatine supplementation group than in the placebo group, indicating a reduced fatigue rate in subjects supplementing with creatine compared with the placebo. Although the results of this study demonstrated reduced fatigue rates in patients during high-intensity sprint intervals, further research is necessary in examining the efficacy of low-dose, short-term creatine supplementation.

  6. Effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 on the left ventricular pressure-volume relationship in the halothane-anesthetized dogs.

    PubMed

    Honda, Atsushi; Nakamura, Yuji; Ohara, Hiroshi; Cao, Xin; Nomura, Hiroaki; Katagi, Jun; Wada, Takeshi; Izumi-Nakaseko, Hiroko; Ando, Kentaro; Sugiyama, Atsushi

    2016-03-15

    Cardiac effects of a prostagrandin EP4-receptor agonist ONO-AE1-329 were assessed in the halothane-anesthetized dogs under the monitoring of left ventricular pressure-volume relationship, which were compared with those of clinically recommended doses of dopamine, dobutamine and milrinone (n=4-5 for each treatment). ONO-AE1-329 was intravenously administered in doses of 0.3, 1 and 3 ng/kg/min for 10 min with a pause of 20 min. Dopamine in a dose of 3 µg/kg/min for 10 min, dobutamine in a dose of 1 µg/kg/min for 10 min and milrinone in a dose of 5 µg/kg/min for 10 min followed by 0.5 µg/kg/min for 10 min were intravenously administered. Low dose of ONO-AE1-329 increased the stroke volume. Middle dose of ONO-AE1-329 increased the cardiac output, left ventricular end-diastolic volume, ejection fraction, maximum upstroke/downstroke velocities of the left ventricular pressure and external work, but decreased the end-systolic pressure and internal work besides the change by the low dose. High dose of ONO-AE1-329 increased the heart rate and maximum elastance, but decreased the end-systolic volume besides the changes by the middle dose. Dopamine, dobutamine and milrinone exerted essentially similar cardiac effects to ONO-AE1-329, but they did not significantly change the end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, end-systolic pressure, maximum elastance, external work or internal work. Thus, EP4-receptor stimulation by ONO-AE1-329 may have potential to better promote the passive ventricular filling than the conventional cardiotonic drugs, which could become a candidate of novel therapeutic strategy for the treatment of heart failure with preserved ejection fraction. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. On the development of a VIPARnd radiotherapy 3D polymer gel dosimeter

    NASA Astrophysics Data System (ADS)

    Kozicki, Marek; Jaszczak, Malwina; Maras, Piotr; Dudek, Mariusz; Cłapa, Marian

    2017-02-01

    This work presents an improvement of the VIPARnd (‘nd’ stands for ‘normoxic, double’, or VIP) polymer gel dosimeter. The gel composition was altered by increasing the concentration of the monomeric components, N-vinylpyrrolidone (NVP) and N,N‧-methylenebisacrylamide (MBA), in co-solvent solutions. The optimal composition (VIPARCT, where ‘CT’ stands for computed tomography, or VIC) comprised: 17% NVP, 8% MBA, 12% t-BuOH, 7.5% gelatine, 0.007% ascorbic acid, 0.0008% CuSO4  ×  5H2O and 0.02% hydroquinone. The following characteristics of VIC were achieved: (i) linear dose range of 0.9_30 Gy, (ii) saturation for radiation doses of over 50 Gy, (iii) threshold dose of about 0.5 Gy, (iv) dose sensitivity of 0.171 Gy-1 s-1, which is roughly 2.2 times higher than that of VIP (for nuclear magnetic resonance measurements). It was also found that VIC is dose- rate-independent, and its dose response does not alter if the radiation source is changed from electrons to photons for external beam radiotherapy. The gel responded similarly to irradiation with small changes in radiation energy but was sensitive to larger energy changes. The VIC gel retained temporal stability from 20 h until at least 10 d after irradiation, whereas spatial stability was retained from 20 h until at least 6 d after irradiation. The scheme adopted for VIC manufacturing yields repeatable gels in terms of radiation dose response. The VIC was also shown to perform better than VIP using x-ray computed tomography as a readout method; the dose sensitivity of VIC (0.397 HU Gy-1) was 1.5 times higher than that of VIP. Also, the dose resolution of VIC was better than that of VIP in the whole dose range examined.

  8. Pharmacokinetic Correlates of the Effects of a Heroin Vaccine on Heroin Self-Administration in Rats

    PubMed Central

    Raleigh, Michael D.; Pentel, Paul R.; LeSage, Mark G.

    2014-01-01

    The purpose of this study was to evaluate the effects of a morphine-conjugate vaccine (M-KLH) on the acquisition, maintenance, and reinstatement of heroin self-administration (HSA) in rats, and on heroin and metabolite distribution during heroin administration that approximated the self-administered dosing rate. Vaccination with M-KLH blocked heroin-primed reinstatement of heroin responding. Vaccination also decreased HSA at low heroin unit doses but produced a compensatory increase in heroin self-administration at high unit doses. Vaccination shifted the heroin dose-response curve to the right, indicating reduced heroin potency, and behavioral economic demand curve analysis further confirmed this effect. In a separate experiment heroin was administered at rates simulating heroin exposure during HSA. Heroin and its active metabolites, 6-acetylmorphine (6-AM) and morphine, were retained in plasma and metabolite concentrations were reduced in brain in vaccinated rats compared to controls. Reductions in 6-AM concentrations in brain after vaccination were consistent with the changes in HSA rates accompanying vaccination. These data provide evidence that 6-AM is the principal mediator of heroin reinforcement, and the principal target of the M-KLH vaccine, in this model. While heroin vaccines may have potential as therapies for heroin addiction, high antibody to drug ratios appear to be important for obtaining maximal efficacy. PMID:25536404

  9. Low dose or low dose rate ionizing radiation-induced health effect in the human.

    PubMed

    Tang, Feng Ru; Loganovsky, Konstantin

    2018-06-05

    The extensive literature review on human epidemiological studies suggests that low dose ionizing radiation (LDIR) (≤100 mSv) or low dose rate ionizing radiation (LDRIR) (<6mSv/H) exposure could induce either negative or positive health effects. These changes may depend on genetic background, age (prenatal day for embryo), sex, nature of radiation exposure, i.e., acute or chronic irradiation, radiation sources (such as atomic bomb attack, fallout from nuclear weapon test, nuclear power plant accidents, 60 Co-contaminated building, space radiation, high background radiation, medical examinations or procedures) and radionuclide components and human epidemiological experimental designs. Epidemiological and clinical studies show that LDIR or LDRIR exposure may induce cancer, congenital abnormalities, cardiovascular and cerebrovascular diseases, cognitive and other neuropsychiatric disorders, cataracts and other eye and somatic pathology (endocrine, bronchopulmonary, digestive, etc). LDIR or LDRIR exposure may also reduce mutation and cancer mortality rates. So far, the mechanisms of LDIR- or LDRIR -induced health effect are poorly understood. Further extensive studies are still needed to clarify under what circumstances, LDIR or LDRIR exposure may induce positive or negative effects, which may facilitate development of new therapeutic approaches to prevent or treat the radiation-induced human diseases or enhance radiation-induced positive health effect. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Classification of radiation effects for dose limitation purposes: history, current situation and future prospects

    PubMed Central

    Hamada, Nobuyuki; Fujimichi, Yuki

    2014-01-01

    Radiation exposure causes cancer and non-cancer health effects, each of which differs greatly in the shape of the dose–response curve, latency, persistency, recurrence, curability, fatality and impact on quality of life. In recent decades, for dose limitation purposes, the International Commission on Radiological Protection has divided such diverse effects into tissue reactions (formerly termed non-stochastic and deterministic effects) and stochastic effects. On the one hand, effective dose limits aim to reduce the risks of stochastic effects (cancer/heritable effects) and are based on the detriment-adjusted nominal risk coefficients, assuming a linear-non-threshold dose response and a dose and dose rate effectiveness factor of 2. On the other hand, equivalent dose limits aim to avoid tissue reactions (vision-impairing cataracts and cosmetically unacceptable non-cancer skin changes) and are based on a threshold dose. However, the boundary between these two categories is becoming vague. Thus, we review the changes in radiation effect classification, dose limitation concepts, and the definition of detriment and threshold. Then, the current situation is overviewed focusing on (i) stochastic effects with a threshold, (ii) tissue reactions without a threshold, (iii) target organs/tissues for circulatory disease, (iv) dose levels for limitation of cancer risks vs prevention of non-life-threatening tissue reactions vs prevention of life-threatening tissue reactions, (v) mortality or incidence of thyroid cancer, and (vi) the detriment for tissue reactions. For future discussion, one approach is suggested that classifies radiation effects according to whether effects are life threatening, and radiobiological research needs are also briefly discussed. PMID:24794798

  11. Sub-dissociative-dose intranasal ketamine for moderate to severe pain in adult emergency department patients.

    PubMed

    Yeaman, Fiona; Meek, Robert; Egerton-Warburton, Diana; Rosengarten, Pamela; Graudins, Andis

    2014-06-01

    There are currently no studies assessing effectiveness of sub-dissociative intranasal (IN) ketamine as the initial analgesic for adult patients in the ED. The study aims to examine the effectiveness of sub-dissociative IN ketamine as a primary analgesic agent for adult patients in the ED. This is a prospective, observational study of adult ED patients presenting with severe pain (≥6 on 11-point scale at triage). IN ketamine dose was 0.7 mg/kg, with secondary dose of 0.5 mg/kg at 15 min if pain did not improve. After 6 months, initial dose was increased to 1.0 mg/kg with the same optional secondary dose. The primary outcomes are change in VAS rating at 30 min; percentage of patients reporting clinically significant reduction in VAS (≥20 mm) at 30 min; dose resulting in clinically significant pain reduction. Of the 72 patients available for analysis, median age was 34.5 years and 64% were men. Median initial VAS rating was 76 mm (interquartile range [IQR]: 65-82). Median total dose of IN ketamine for all patients was 0.98 mg/kg (IQR: 0.75-1.15, range: 0.59-1.57). Median reduction in VAS rating at 30 min was 24 mm (IQR: 2-45). Forty (56%, 95% CI: 44.0-66.7) reported VAS reduction ≥20 mm, these patients having had a total median ketamine dose of 0.94 mg/kg (IQR: 0.72-1.04). IN ketamine, at a dose of about 1 mg/kg, was an effective analgesic agent in 56% of study patients. The place of IN ketamine in analgesic guidelines for adults requires further investigation. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  12. Space radiation risks to the central nervous system

    NASA Astrophysics Data System (ADS)

    Cucinotta, Francis A.; Alp, Murat; Sulzman, Frank M.; Wang, Minli

    2014-07-01

    Central nervous system (CNS) risks which include during space missions and lifetime risks due to space radiation exposure are of concern for long-term exploration missions to Mars or other destinations. Possible CNS risks during a mission are altered cognitive function, including detriments in short-term memory, reduced motor function, and behavioral changes, which may affect performance and human health. The late CNS risks are possible neurological disorders such as premature aging, and Alzheimer's disease (AD) or other dementia. Radiation safety requirements are intended to prevent all clinically significant acute risks. However the definition of clinically significant CNS risks and their dependences on dose, dose-rate and radiation quality is poorly understood at this time. For late CNS effects such as increased risk of AD, the occurrence of the disease is fatal with mean time from diagnosis of early stage AD to death about 8 years. Therefore if AD risk or other late CNS risks from space radiation occur at mission relevant doses, they would naturally be included in the overall acceptable risk of exposure induced death (REID) probability for space missions. Important progress has been made in understanding CNS risks due to space radiation exposure, however in general the doses used in experimental studies have been much higher than the annual galactic cosmic ray (GCR) dose (∼0.1 Gy/y at solar maximum and ∼0.2 Gy/y at solar minimum with less than 50% from HZE particles). In this report we summarize recent space radiobiology studies of CNS effects from particle accelerators simulating space radiation using experimental models, and make a critical assessment of their relevance relative to doses and dose-rates to be incurred on a Mars mission. Prospects for understanding dose, dose-rate and radiation quality dependencies of CNS effects and extrapolation to human risk assessments are described.

  13. Rectal bleeding after high-dose-rate brachytherapy combined with hypofractionated external-beam radiotherapy for localized prostate cancer: Impact of rectal dose in high-dose-rate brachytherapy on occurrence of grade 2 or worse rectal bleeding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Kitamoto, Yoshizumi

    2006-06-01

    Purpose: To evaluate the incidence of Grade 2 or worse rectal bleeding after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiotherapy (EBRT), with special emphasis on the relationship between the incidence of rectal bleeding and the rectal dose from HDR brachytherapy. Methods and Materials: The records of 100 patients who were treated by HDR brachytherapy combined with EBRT for {>=}12 months were analyzed. The fractionation schema for HDR brachytherapy was prospectively changed, and the total radiation dose for EBRT was fixed at 51 Gy. The distribution of the fractionation schema used in the patients was as follows: 5 Gy xmore » 5 in 13 patients; 7 Gy x 3 in 19 patients; and 9 Gy x 2 in 68 patients. Results: Ten patients (10%) developed Grade 2 or worse rectal bleeding. Regarding the correlation with dosimetric factors, no significant differences were found in the average percentage of the entire rectal volume receiving 30%, 50%, 80%, and 90% of the prescribed radiation dose from EBRT between those with bleeding and those without. The average percentage of the entire rectal volume receiving 10%, 30%, 50%, 80%, and 90% of the prescribed radiation dose from HDR brachytherapy in those who developed rectal bleeding was 77.9%, 28.6%, 9.0%, 1.5%, and 0.3%, respectively, and was 69.2%, 22.2%, 6.6%, 0.9%, and 0.4%, respectively, in those without bleeding. The differences in the percentages of the entire rectal volume receiving 10%, 30%, and 50% between those with and without bleeding were statistically significant. Conclusions: The rectal dose from HDR brachytherapy for patients with prostate cancer may have a significant impact on the incidence of Grade 2 or worse rectal bleeding.« less

  14. [Brachytherapy for head and neck cancers].

    PubMed

    Peiffert, D; Coche-Dequéant, B; Lapeyre, M; Renard, S

    2018-05-29

    The main indications of the brachytherapy of head and neck cancers are the limited tumours of the lip, the nose, the oral cavity and the oropharynx. Nasopharynx tumours are nowadays treated by intensity-modulated radiotherapy. This technique can be exclusive, associated with external radiotherapy or postoperative. It can also be a salvage treatment for the second primaries in previously irradiated areas. If the low dose rate brachytherapy rules remain the reference, the pulse dose rate technique allows the prescription of the dose rate and the optimisation of the dose distribution. Results of high dose rate brachytherapy are now published. This paper reports the recommendations of the Gec-ESTRO, published in 2017, and takes into account the data of the historical low dose rate series, and is upgraded with the pulsed-dose rate and high dose rate series. Copyright © 2018. Published by Elsevier SAS.

  15. Experimental ultraviolet photocarcinogenesis: wavelength interactions and time-dose relationships.

    PubMed

    Forbes, P D; Davies, R E; Urbach, F

    1978-12-01

    Tumors were induced in the skin of SKH hairless mice by exposure to fluorescent FS sun lamps or to a long-arc xenon solar simulator. Tumores developed about equally well with varying amounts of UV-A radiation (lambda greater than 320 nm) given simultaneously. In contrast, incremental changes in the UV-B region (lambda less than 320 nm) led to substantial increases in carcinogenic effectiveness. A tumor-"initiating" dose of UV-B (4-10 wk of daily FS lamp exposures) was rendered less effective by subsequent exposures of the mice to UV-A (6 hr/day, F-40 T12BL lamps). The mechanism for this effect is not known. Most tumors induced by a short course (10 wk) of FS lamp exposure grew slowly or regressed, whereas mice exposed for a longer period (30 wk) developed more tumors, and many of those that appeared early grew aggressively. Effects of daily dose fractionation were less clear, and the subject requires further study. These and other variables are being tested in a program designed to yield useful information on the effects of changing spectrum, dose, and dose delivery rates on sunlight-induced cancer.

  16. Gamma Knife surgery for intracranial chordoma and chondrosarcoma: radiosurgical perspectives and treatment outcomes.

    PubMed

    Kim, Ji Hee; Jung, Hyun Ho; Chang, Jong Hee; Chang, Jin Woo; Park, Yong Gou; Chang, Won Seok

    2014-12-01

    Intracranial chordomas and chondrosarcomas are histologically low-grade, locally invasive tumors that are reported to be similar in terms of anatomical location, clinical presentation, and radiological findings but different in terms of behavior and outcomes. The purpose of this study was to investigate and compare clinical outcomes after Gamma Knife surgery (GKS) for the treatment of intracranial chordoma and chondrosarcoma. The authors conducted a retrospective review of the results of radiosurgical treatment of intracranial chordomas and chondrosarcomas. They enrolled patients who had undergone GKS for intracranial chordoma or chondrosarcoma at the Yonsei Gamma Knife Center, Yonsei University College of Medicine, from October 2000 through June 2007. Analyses included only patients for whom the disease was pathologically diagnosed before GKS and for whom more than 5 years of follow-up data after GKS were available. Rates of progression-free survival and overall survival were analyzed and compared according to tumor pathology. Moreover, the association between tumor control and the margin radiation dose to the tumor was analyzed, and the rate of tumor volume change after GKS was quantified. A total of 10 patients were enrolled in this study. Of these, 5 patients underwent a total of 8 sessions of GKS for chordoma, and the other 5 patients underwent a total of 7 sessions of GKS for chondrosarcoma. The 2- and 5-year progression-free survival rates for patients in the chordoma group were 70% and 35%, respectively, and rates for patients in the chondrosarcoma group were 100% and 80%, respectively (log-rank test, p = 0.04). The 2- and 5-year overall survival rates after GKS for patients in the chordoma group were 87.5% and 72.9%, respectively, and rates for patients in the chondrosarcoma group were 100% and 100%, respectively (log-rank test, p = 0.03). The mean rates of tumor volume change 2 years after radiosurgery were 79.64% and 39.91% for chordoma and chondrosarcoma, respectively (p = 0.05). No tumor progression was observed when margin doses greater than 16 Gy for chordoma and 14 Gy for chondrosarcoma were prescribed. Outcomes after GKS were more favorable for patients with chondrosarcoma than for those with chordoma. The data also indicated that at 2 years after GKS, the rate of volume change is significantly higher for chordomas than for chondrosarcomas. The authors conclude that radiosurgery with a margin dose of more than 16 Gy for chordomas and more than 14 Gy for chondrosarcomas seems to enhance local tumor control with relatively few complications. Further studies are needed to determine the optimal dose of GKS for patients with intracranial chordoma or chondrosarcoma.

  17. Effect of gamma irradiation on the properties of tyre cords

    NASA Astrophysics Data System (ADS)

    Aytaç, Ayşe; Şen, Murat; Deniz, Veli; Güven, Olgun

    2007-12-01

    Gamma irradiation of high tenacity Nylon 6.6 (Ny 66) and polyester (PET) tyre cords was investigated. The untreated and treated tyre cords with different twist levels were irradiated at different dose rates in air. The effects of irradiation on both Ny 66 and PET cords were not found to be depending on the twist levels of the cords. The changes in the mechanical and thermal properties with absorbed dose at two different dose rates were measured. The mechanical properties were observed to deteriorate with increasing dose for Ny 66 cords, whereas remained almost unchanged for PET cords both in greige and dipped forms. Hot shrinkage value for the greige Ny 66 cords was found to be improved, i.e. decreased. This decrease was much lower for greige PET than Ny 66 cords. It is concluded that PET cord has higher radiation resistance than Ny 66 cord and the effects of high energy irradiation on tyre cords have to be taken into consideration during tyre design if pre-vulcanization with high energy radiation is to be applied.

  18. The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers.

    PubMed

    Rau, A W; Bakueva, L; Rowlands, J A

    2005-10-01

    Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristics of FPIs can be affected by ghosting (i.e., radiation-induced changes of sensitivity) when the dose to the detector is high (e.g., portal imaging and mammography) or the images are acquired at a high frame rate (e.g., fluoroscopy). In this paper, the x-ray time-of-flight (TOF) method is introduced as a tool for the investigation of ghosting in a-Se photoconductor layers. The method consists of irradiating layers of a-Se with short x-ray pulses. From the current generated in the a-Se layer, ghosting is quantified and the ghosting parameters (charge carrier generation rate and carrier lifetimes and mobilities) are assessed. The x-ray TOF method is novel in that (1) x-ray sensitivity (S) and ghosting parameters can be measured simultaneously, (2) the transport of both holes and electrons can be isolated, and (3) the method is applicable to the practical a-Se layer structure with blocking contacts used in FPIs. The x-ray TOF method was applied to an analysis of ghosting in a-Se photoconductor layers under portal imaging conditions, i.e., 1 mm thick a-Se layers, biased at 5 V/ microm, were irradiated using a 6 MV LINAC x-ray beam to a total dose (ghosting dose) of 30 Gy. The initial sensitivity (S0) of the a-Se layers was 63 +/- 2 nC cm(-2) cGy(-1). It was found that S decreases to 30% of S0 after a ghosting dose of 5 Gy and to 21% after 30 Gy at which point no further change in S occurs. At an x-ray intensity of 22 Gy/s (instantaneous dose rate during a LINAC x-ray pulse), the charge carrier generation rate was 1.25 +/- 0.1 x 10(22) ehp m(-3) s(-1) and, to a first approximation, independent of the ghosting dose. However, both hole and electron transport showed a strong dependence on the ghosting dose: hole transport decreased by 61%, electron transport by up to approximately 80%. Therefore, degradation of both hole and electron transport due to the recombination of mobile charge carriers with trapped carriers (of opposite polarity) were identified as the main cause of ghosting in this study.

  19. Numerical simulation of the radiation environment on Martian surface

    NASA Astrophysics Data System (ADS)

    Zhao, L.

    2015-12-01

    The radiation environment on the Martian surface is significantly different from that on earth. Existing observation and studies reveal that the radiation environment on the Martian surface is highly variable regarding to both short- and long-term time scales. For example, its dose rate presents diurnal and seasonal variations associated with atmospheric pressure changes. Moreover, dose rate is also strongly influenced by the modulation from GCR flux. Numerical simulation and theoretical explanations are required to understand the mechanisms behind these features, and to predict the time variation of radiation environment on the Martian surface if aircraft is supposed to land on it in near future. The high energy galactic cosmic rays (GCRs) which are ubiquitous throughout the solar system are highly penetrating and extremely difficult to shield against beyond the Earth's protective atmosphere and magnetosphere. The goal of this article is to evaluate the long term radiation risk on the Martian surface. Therefore, we need to develop a realistic time-dependent GCR model, which will be integrated with Geant4 transport code subsequently to reproduce the observed variation of surface dose rate associated with the changing heliospheric conditions. In general, the propagation of cosmic rays in the interplanetary medium can be described by a Fokker-Planck equation (or Parker equation). In last decade,we witnessed a fast development of GCR transport models within the heliosphere based on accurate gas-dynamic and MHD backgrounds from global models of the heliosphere. The global MHD simulation produces a more realistic pattern of the 3-D heliospheric structure, as well as the interface between the solar system and the surrounding interstellar space. As a consequence, integrating plasma background obtained from global-dependent 3-D MHD simulation and stochastic Parker transport simulation, we expect to produce an accurate global physical-based GCR modulation model. Combined with the Geant4 transport code, this GCR model will provide valuable insight into the long-term dose rates variation on the Martian surface.

  20. Low-dose/dose-rate γ radiation depresses neural differentiation and alters protein expression profiles in neuroblastoma SH-SY5Y cells and C17.2 neural stem cells.

    PubMed

    Bajinskis, Ainars; Lindegren, Heléne; Johansson, Lotta; Harms-Ringdahl, Mats; Forsby, Anna

    2011-02-01

    The effects of low doses of ionizing radiation on cellular development in the nervous system are presently unclear. The focus of the present study was to examine low-dose γ-radiation-induced effects on the differentiation of neuronal cells and on the development of neural stem cells to glial cells. Human neuroblastoma SH-SY5Y cells were exposed to (137)Cs γ rays at different stages of retinoic acid-induced neuronal differentiation, and neurite formation was determined 6 days after exposure. When SH-SY5Y cells were exposed to low-dose-rate γ rays at the onset of differentiation, the number of neurites formed per cell was significantly less after exposure to either 10, 30 or 100 mGy compared to control cells. Exposure to 10 and 30 mGy attenuated differentiation of immature C17.2 mouse-derived neural stem cells to glial cells, as verified by the diminished expression of glial fibrillary acidic protein. Proteomic analysis of the neuroblastoma cells by 2D-PAGE after 30 mGy irradiation showed that proteins involved in neuronal development were downregulated. Proteins involved in cell cycle and proliferation were altered in both cell lines after exposure to 30 mGy; however, the rate of cell proliferation was not affected in the low-dose range. The radiation-induced attenuation of differentiation and the persistent changes in protein expression is indicative of an epigenetic rather than a cytotoxic mechanism.

  1. An accurate derivation of the air dose-rate and the deposition concentration distribution by aerial monitoring in a low level contaminated area

    NASA Astrophysics Data System (ADS)

    Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo

    2015-04-01

    Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.

  2. ECT treatment outcomes following performance improvement changes.

    PubMed

    Pulia, Kathy; Vaidya, Punit; Jayaram, Geetha; Hayat, Matthew J; Reti, Irving M

    2013-11-01

    Differences in electroconvulsive therapy (ECT) outcomes were explored following changes in ECT administration at our institution. Two changes were introduced: (a) switching the anesthetic agent from propofol to methohexital, and (b) using a more aggressive ECT charge dosing regimen for right unilateral (RUL) electrode placement. Length of stay (LOS) and number of treatments administered per patient were monitored. A retrospective analysis was performed of two inpatient groups treated on our Mood Disorders Unit: those who underwent ECT in the 12 months prior to the changes (n = 40) and those who underwent treatment in the 12 months after the changes (n = 38). Compared with patients receiving ECT with RUL placement prior to the changes, patients who received RUL ECT after the changes had a significantly shorter inpatient LOS (27.4 versus 18 days, p = 0.028). Treatment efficacy monitored by the Montgomery Asberg Depression Rating Scale was not impacted. The change in anesthetic agent and charge dosing each accounted for 11% of the variance in LOS among patients receiving RUL ECT. The implemented changes in ECT administration positively impacted outcome for patients receiving treatment with RUL electrode placement. Copyright 2013, SLACK Incorporated.

  3. Dose-response relationship of cardiorespiratory fitness adaptation to controlled endurance training in sedentary older adults.

    PubMed

    Huang, Guoyuan; Wang, Ru; Chen, Peijie; Huang, Sunny C; Donnelly, Joseph E; Mehlferber, Jon P

    2016-03-01

    The purpose of this investigation was to identify a quantitative dose-response relationship for enhancing maximal oxygen consumption (VO2max) in healthy sedentary older adults after controlled endurance training. This meta-analysis of controlled clinical trials included 1257 exercisers and 845 controls with a mean age of 67.45 ± 5.25 years. Effect sizes were calculated for training-induced VO2max changes. Different training regimens were analyzed and compared. The weighted net change of the mean VO2max values showed a significant increase of 3.78 ml/kg per min (95% confidence interval = 3.29 to 4.27; p < 0.0001) in response to aerobic training. Interstudy differences in VO2max changes were significantly related to exercise intensity, and explained approximately 11% of the variance of the VO2max responses. VO2max improved significantly at 35%-50% heart rate reserve (HRR) and continued improving at a greater rate with increasing "dose". The largest VO2max-improvement adaptation was achieved with a mean intensity of 66%-73% HRR. The magnitudes of the VO2max adaptation are identical to exercise at 57%-65% HRR and at 75%-80% HRR. Higher intensity doses more than 75-80% HRR did not lead to greater enhancement of VO2max improvements but, conversely, resulted in large declines. Our data provide quantitative insight into the magnitude of VO2max alterations as affected by exercise intensity, duration, frequency, and program length. The shapes of the dose-response curves are not simply linear, but with many similar trends and noteworthy characteristics. Aerobic training at a mean intensity of 66%-73% HRR with 40-50 min per session for 3-4 day/week for 30-40 weeks appears to be effective and optimal for maximum cardiorespiratory benefits in healthy sedentary older adults. © The European Society of Cardiology 2015.

  4. The Effects of Low Doses of Gamma-Radiation on Growth and Membrane Activity of Pseudomonas aeruginosa GRP3 and Escherichia coli M17.

    PubMed

    Soghomonyan, D; Margaryan, A; Trchounian, K; Ohanyan, K; Badalyan, H; Trchounian, A

    2018-06-01

    Microorganisms are part of the natural environments and reflect the effects of different physical factors of surrounding environment, such as gamma (γ) radiation. This work was devoted to the study of the influence of low doses of γ radiation with the intensity of 2.56 μW (m 2  s) -1 (absorbed doses were 3.8 mGy for the radiation of 15 min and 7.2 mGy-for 30 min) on Escherichia coli M-17 and Pseudomonas aeruginosa GRP3 wild type cells. The changes of bacterial, growth, survival, morphology, and membrane activity had been studied after γ irradiation. Verified microbiological (specific growth rate, lag phase duration, colony-forming units (CFU) number, and light microscopy digital image analysis), biochemical (ATPase activity of bacterial membrane vesicles), and biophysical (H + fluxes throughout cytoplasmic membrane of bacteria) methods were used for assessment of radiation implications on bacteria. It was shown that growth specific rate, lag phase duration and CFU number of these bacteria were lowered after irradiation, and average cell surface area was decreased too. Moreover ion fluxes of bacteria were changed: for P. aeruginosa they were decreased and for E. coli-increased. The N,N'-dicyclohexylcarbodiimide (DCCD) sensitive fluxes were also changed which were indicative for the membrane-associated F 0 F 1 -ATPase enzyme. ATPase activity of irradiated membrane vesicles was decreased for P. aeruginosa and stimulated for E. coli. Furthermore, DCCD sensitive ATPase activity was also changed. The results obtained suggest that these bacteria especially, P. aeruginosa are sensitive to γ radiation and might be used for developing new monitoring methods for estimating environmental changes after γ irradiation.

  5. Patient controlled sedation using a standard protocol for dressing changes in burns: patients' preference, procedural details and a preliminary safety evaluation.

    PubMed

    Nilsson, Andreas; Steinvall, Ingrid; Bak, Zoltan; Sjöberg, Folke

    2008-11-01

    Patient controlled sedation (PCS) enables patients to titrate doses of drugs by themselves during different procedures involving pain or discomfort. We studied it in a prospective crossover design using a fixed protocol without lockout time to examine it as an alternative method of sedation for changing dressings in burned patients. Eleven patients with >10% total burn surface area (TBSA) had their dressings changed, starting with sedation by an anaesthetist (ACS). The second dressing change was done with PCS (propofol/alfentanil) and the third time the patients had to choose ACS or PCS. During the procedures, data on cardiopulmonary variables, sedation (bispectral index), pain intensity (VAS), procedural details, doses of drugs, and patients' preferences were collected to compare the two sedation techniques. The study data indicated that wound care in burned patients is feasible with a standardized PCS protocol. The patients preferred PCS to ACS on the basis of self-control, and because they had less discomfort during the recovery period. Wound care was also considered adequate by the staff during PCS. No respiratory (respiratory rate/transcutaneous PCO(2)) or cardiovascular (heart rate/blood pressure) adverse events were recorded at any time during any of the PCS procedures. The doses of propofol and alfentanil and BIS index decrease were less during PCS than ACS. Procedural pain was higher during PCS but lower after the procedure. We suggest that PCS using a standard protocol is an interesting alternative to anaesthetist-provided sedation during dressing changes. It seems effective, saves resources, is safe, and at same time is preferred by the patients. The strength of these conclusions is, however, hampered by the small size of this investigation and therefore further studies are warranted.

  6. Can a Compact Pre-Filled Auto-Disable Injection System (cPAD) Save Costs for DTP-HepB-Hib Vaccine as Compared with Single-Dose (SDV) and Multi-Dose Vials (MDV)? Evidence from Cambodia, Ghana, and Peru.

    PubMed

    Nogier, Cyril; Hanlon, Patrick; Wiedenmayer, Karin; Maire, Nicolas

    2015-03-01

    A compact pre-filled auto-disable injection (cPAD) presentation is being developed for the fully liquid pentavalent DTP-HepB-Hib vaccine. A cost analysis (CA) to compare this presentation with the presently used single-dose vial (SDV) and multi-dose vial (MDV) was conducted in Cambodia, Ghana, and Peru. The CA included the development of an excel-based costing model and considered the costs of vaccine, safe injection equipment, procurement, storage, transport and distribution, vaccine administration by health staff, medical waste management, start-up activities, as well as coverage, birth cohort, vaccine, and safe injection equipment wastage rates. The outcome was the change in cost per pentavalent fully immunized child (PFIC) for a switch to cPAD. Field visits to health facilities, and interviews with key informants from immunization services and regulatory authorities, were conducted to collect data and to test the costing model in country context. Cost data were also obtained from manufacturers, published price lists, and author estimates. A sensitivity analysis (SA) was conducted to explore possible variations in values of data collected. Based on vaccine price trends estimated for 2016, cPAD is less costly in Ghana [incremental cost per PFIC: $US-0.59 (-6.46 %)] than the current presentation (ten-dose MDV) and in Peru (SDV): $US-0.89 (-7.14 %). In Cambodia, cPAD is more costly than SDV: $US+0.33 (+3.90 %). The most significant cost item per PFIC is the vaccine (reflecting wastage rates) in all presentations. The dominance of the vaccine price per dose and, to a lesser extent, the wastage rates in the incremental cost per PFIC show potential to simplify future analyses. Other relevant considerations at country level for a change of presentation include the potential for improved safety with cPAD, planned introduction of other vaccines, environmental and safety issues, and financial sustainability.

  7. Beneficial effect of soy isoflavones on bone mineral content was modified by years since menopause, body weight, and calcium intake: a double-blind, randomized, controlled trial.

    PubMed

    Chen, Yu-Ming; Ho, Suzanne C; Lam, Silvia S H; Ho, Susan S S; Woo, Jean L F

    2004-01-01

    Many studies have shown that soy isoflavones have an effect in preventing estrogen-related bone loss, but no data reported whether such an effect could be influenced by other important factors affecting bone loss. This study examines whether the associations between isoflavone supplementation and rates of change in bone mineral content (BMC) could be modified by years since menopause (YSM), body weight (BW), and dietary calcium intake in postmenopausal Chinese women aged 48 to 62 years. A group of 203 eligible women were randomly assigned to three treatment groups: placebo (daily dose of 0 mg isoflavones + 500 mg calcium, n = 67), mid-dose (40 mg isoflavones + 500 mg calcium, n = 68); and high-dose (80 mg isoflavones + 500 mg calcium, n = 68). Bone mineral density (BMD) and BMC at the whole body, spine, and hip were measured by dual-energy x-ray absorptiometry at baseline and posttreatment after 1 year. YSM, BW, and dietary calcium intake stratified analyses were performed to evaluate whether the associations between isoflavones supplementation and BMC change rates were varied with these factors. Both univariate and multivariate analyses observed significant favorable effect of isoflavone supplementation on rates of change in BMC at the total hip and trochanter among later postmenopausal women (> 4 y), in women with lower BW (< or =median, 55.5 kg), or among women with lower level of calcium intake (< or =median, 1095 mg/d). The independent effect of soy on the maintenance of hip BMC is more marked in women in later menopause or those with lower BW or calcium intake.

  8. Leuco-crystal-violet micelle gel dosimeters: Component effects on dose-rate dependence

    NASA Astrophysics Data System (ADS)

    Xie, J. C.; Katz, E. A. B.; Alexander, K. M.; Schreiner, L. J.; McAuley, K. B.

    2017-05-01

    Designed experiments were performed to produce empirical models for the dose sensitivity, initial absorbance, and dose-rate dependence respectively for leucocrystal violet (LCV) micelle gel dosimeters containing cetyltrimethylammonium bromide (CTAB) and 2,2,2-trichloroethanol (TCE). Previous gels of this type showed dose-rate dependent behaviour, producing an ˜18% increase in dose sensitivity between dose rates of 100 and 600 cGy min-1. Our models predict that the dose rate dependence can be reduced by increasing the concentration of TCE, CTAB and LCV. Increasing concentrations of LCV and CTAB produces a significant increase in dose sensitivity with a corresponding increase in initial absorbance. An optimization procedure was used to determine a nearly dose-rate independent gel which maintained high sensitivity and low initial absorbance. This gel which contains 33 mM CTAB, 1.25 mM LCV, and 96 mM TCE in 25 mM trichloroacetic acid and 4 wt% gelatin showed an increase in dose sensitivity of only 4% between dose rates of 100 and 600 cGy min-1, and provides an 80% greater dose sensitivity compared to Jordan’s standard gels with similar initial absorbance.

  9. Estimation of the Dose and Dose Rate Effectiveness Factor

    NASA Technical Reports Server (NTRS)

    Chappell, L.; Cucinotta, F. A.

    2013-01-01

    Current models to estimate radiation risk use the Life Span Study (LSS) cohort that received high doses and high dose rates of radiation. Transferring risks from these high dose rates to the low doses and dose rates received by astronauts in space is a source of uncertainty in our risk calculations. The solid cancer models recommended by BEIR VII [1], UNSCEAR [2], and Preston et al [3] is fitted adequately by a linear dose response model, which implies that low doses and dose rates would be estimated the same as high doses and dose rates. However animal and cell experiments imply there should be curvature in the dose response curve for tumor induction. Furthermore animal experiments that directly compare acute to chronic exposures show lower increases in tumor induction than acute exposures. A dose and dose rate effectiveness factor (DDREF) has been estimated and applied to transfer risks from the high doses and dose rates of the LSS cohort to low doses and dose rates such as from missions in space. The BEIR VII committee [1] combined DDREF estimates using the LSS cohort and animal experiments using Bayesian methods for their recommendation for a DDREF value of 1.5 with uncertainty. We reexamined the animal data considered by BEIR VII and included more animal data and human chromosome aberration data to improve the estimate for DDREF. Several experiments chosen by BEIR VII were deemed inappropriate for application to human risk models of solid cancer risk. Animal tumor experiments performed by Ullrich et al [4], Alpen et al [5], and Grahn et al [6] were analyzed to estimate the DDREF. Human chromosome aberration experiments performed on a sample of astronauts within NASA were also available to estimate the DDREF. The LSS cohort results reported by BEIR VII were combined with the new radiobiology results using Bayesian methods.

  10. Using RADFET for the real-time measurement of gamma radiation dose rate

    NASA Astrophysics Data System (ADS)

    Andjelković, Marko S.; Ristić, Goran S.; Jakšić, Aleksandar B.

    2015-02-01

    RADFETs (RADiation sensitive Field Effect Transistors) are integrating ionizing radiation dosimeters operating on the principle of conversion of radiation-induced threshold voltage shift into absorbed dose. However, one of the major drawbacks of RADFETs is the inability to provide the information on the dose rate in real-time using the conventional absorbed dose measurement technique. The real-time monitoring of dose rate and absorbed dose can be achieved with the current mode dosimeters such as PN and PIN diodes/photodiodes, but these dosimeters have some limitations as absorbed dose meters and hence they are often not a suitable replacement for RADFETs. In that sense, this paper investigates the possibility of using the RADFET as a real-time dose rate meter so that it could be applied for simultaneous online measurement of the dose rate and absorbed dose. A RADFET sample, manufactured by Tyndall National Institute, Cork, Ireland, was tested as a dose rate meter under gamma irradiation from a Co-60 source. The RADFET was configured as a PN junction, such that the drain, gate and source terminals were grounded, while the radiation-induced current was measured at the bulk terminal, whereby the bulk was successively biased with 0 , 10 , 20  and 30 V. In zero-bias mode the radiation-induced current was unstable, but in the biased mode the current response was stable for the investigated dose rates from 0.65  to 32.1 Gy h-1 and up to the total absorbed dose of 25 Gy. The current increased with the dose rate in accordance with the power law, whereas the sensitivity of the current read-out was linear with respect to the applied bias voltage. Comparison with previously analyzed PIN photodiodes has shown that the investigated RADFET is competitive with PIN photodiodes as a gamma radiation dose rate meter and therefore has the potential to be employed for the real-time monitoring of the dose rate and absorbed dose.

  11. Exercise frequency and bone mineral density development in exercising postmenopausal osteopenic women. Is there a critical dose of exercise for affecting bone? Results of the Erlangen Fitness and Osteoporosis Prevention Study.

    PubMed

    Kemmler, Wolfgang; von Stengel, Simon; Kohl, Matthias

    2016-08-01

    Due to older people's low sports participation rates, exercise frequency may be the most critical component for designing exercise protocols that address bone. The aims of the present article were to determine the independent effect of exercise frequency (ExFreq) and its corresponding changes on bone mineral density (BMD) and to identify the minimum effective dose that just relevantly affects bone. Based on the 16-year follow-up of the intense, consistently supervised Erlangen Fitness and Osteoporosis Prevention-Study, ExFreq was retrospectively determined in the exercise-group of 55 initially early-postmenopausal females with osteopenia. Linear mixed-effect regression analysis was conducted to determine the independent effect of ExFreq on BMD changes at lumbar spine and total hip. Minimum effective dose of ExFreq based on BMD changes less than the 90% quantile of the sedentary control-group (n=43). Cut-offs were determined after 4, 8, 12 and 16years using bootstrap with 5000 replications. After 16years, average ExFreq ranged between 1.02 and 2.96sessions/week (2.28±0.40sessions/week). ExFreq has an independent effect on LS-BMD (p<.001) and hip-BMD (p=.005) changes. Bootstrap analysis detected a minimum effective dose at about 2sessions/week/16years (cut-off LS-BMD: 2.11, 95% CI: 2.06-2.12; total hip-BMD: 2.22, 95% CI: 2.00-2.78sessions/week/16years). In summary, the minimum effective dose of exercise frequency that relevantly addresses BMD is quite high, at least compared with the low sport participation rate of older adults. This result might not be generalizable across all exercise types, protocols and cohorts, but it does indicate at least that even when applying high impact/high intensity programs, exercise frequency and its maintenance play a key role in bone adaptation. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Gamma Irradiation and Oxidative Degradation of a Silica-Filled Silicone Elastomer

    DOE PAGES

    Labouriau, Andrea; Cady, Carl Mcelhinney; Gill, John T.; ...

    2015-03-21

    The radiation oxidative degradation of a commonly used silica-filled silicone elastomer DC745 was investigated by a series of experimental techniques. This elastomer is known to be chemically and thermally stable, but insufficient data exist on the radiation resistance. In the present work, gamma doses up to 200 kGy were applied under air at RT and 1Gy/s. Radiation chemical changes were investigated by NMR, FT-IR, Raman, and mass spectroscopy. DSC and TGA experiments probed thermal transitions and thermal stability changes with exposure dose. SEM probed variations on the surface of the elastomer, and solvent swelling methods were used to investigate changesmore » in the polymer network properties. Electron paramagnetic resonance was employed to detect and identify free radicals. Uniaxial compression load tests at variable temperatures were performed to assess changes in the material’s mechanical response as a function of radiation dose. Results demonstrate that, with increasing exposure, DC745 undergoes changes in chemistry that lead to an increase in thermal stability and cross-link density, formation of free radical species, decrease in heat of fusion and increase in stiffness at low temperatures. Taken together, these results indicate that oxidative cross-linking is the dominant radiolysis mechanism that occurs when this material is exposed to gamma irradiation in air at high dose rates.« less

  13. Gamma Irradiation and Oxidative Degradation of a Silica-Filled Silicone Elastomer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Labouriau, Andrea; Cady, Carl Mcelhinney; Gill, John T.

    The radiation oxidative degradation of a commonly used silica-filled silicone elastomer DC745 was investigated by a series of experimental techniques. This elastomer is known to be chemically and thermally stable, but insufficient data exist on the radiation resistance. In the present work, gamma doses up to 200 kGy were applied under air at RT and 1Gy/s. Radiation chemical changes were investigated by NMR, FT-IR, Raman, and mass spectroscopy. DSC and TGA experiments probed thermal transitions and thermal stability changes with exposure dose. SEM probed variations on the surface of the elastomer, and solvent swelling methods were used to investigate changesmore » in the polymer network properties. Electron paramagnetic resonance was employed to detect and identify free radicals. Uniaxial compression load tests at variable temperatures were performed to assess changes in the material’s mechanical response as a function of radiation dose. Results demonstrate that, with increasing exposure, DC745 undergoes changes in chemistry that lead to an increase in thermal stability and cross-link density, formation of free radical species, decrease in heat of fusion and increase in stiffness at low temperatures. Taken together, these results indicate that oxidative cross-linking is the dominant radiolysis mechanism that occurs when this material is exposed to gamma irradiation in air at high dose rates.« less

  14. Diamond detector in absorbed dose measurements in high-energy linear accelerator photon and electron beams.

    PubMed

    Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Amri, Iqbal; Davis, Cheriyathmanjiyil Antony

    2016-03-08

    Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue-equivalent properties. We investigated a commercially available 'microdiamond' detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1mm, thickness 1 x10(-3) mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ± 0.17% (1 SD) (n = 11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stop-ping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long-term stability and reproducibility. Based on micro-dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance.

  15. LDR brachytherapy: can low dose rate hypersensitivity from the "inverse" dose rate effect cause excessive cell killing to peripherial connective tissues and organs?

    PubMed

    Leonard, B E; Lucas, A C

    2009-02-01

    Examined here are the possible effects of the "inverse" dose rate effect (IDRE) on low dose rate (LDR) brachytherapy. The hyper-radiosensitivity and induced radioresistance (HRS/IRR) effect benefits cell killing in radiotherapy, and IDRE and HRS/IRR seem to be generated from the same radioprotective mechanisms. We have computed the IDRE excess cell killing experienced in LDR brachytherapy using permanent seed implants. We conclude, firstly, that IDRE is a dose rate-dependent manifestation of HRS/IRR. Secondly, the presence of HRS/IRR or IDRE in a cell species or tissue must be determined by direct dose-response measurements. Thirdly, a reasonable estimate is that 50-80% of human adjoining connective and organ tissues experience IDRE from permanent implanted LDR brachytherapy. If IDRE occurs for tissues at point A for cervical cancer, the excess cell killing will be about a factor of 3.5-4.0 if the initial dose rate is 50-70 cGy h(-1). It is greater for adjacent tissues at lower dose rates and higher for lower initial dose rates at point A. Finally, higher post-treatment complications are observed in LDR brachytherapy, often for unknown reasons. Some of these are probably a result of IDRE excess cell killing. Measurements of IDRE need be performed for connective and adjacent organ tissues, i.e. bladder, rectum, urinary tract and small bowels. The measured dose rate-dependent dose responses should extended to <10 cGy h(-1) and involve multiple patients to detect patient variability. Results may suggest a preference for high dose rate brachytherapy or LDR brachytherapy without permanent retention of the implant seeds (hence the dose rates in peripheral tissues and organs remain above IDRE thresholds).

  16. Recombination in liquid-filled ionization chambers beyond the Boag limit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brualla-González, L.; Roselló, J.

    Purpose: The high mass density and low mobilities of charge carriers can cause important recombination in liquid-filled ionization chambers (LICs). Saturation correction methods have been proposed for LICs. Correction methods for pulsed irradiation are based on Boag equation. However, Boag equation assumes that the charge ionized by one pulse is fully collected before the arrival of the next pulse. This condition does not hold in many clinical beams where the pulse repetition period may be shorter than the charge collection time, causing overlapping between charge carriers ionized by different pulses, and Boag equation is not applicable there. In this work,more » the authors present an experimental and numerical characterization of collection efficiencies in LICs beyond the Boag limit, with overlapping between charge carriers ionized by different pulses. Methods: The authors have studied recombination in a LIC array for different dose-per-pulse, pulse repetition frequency, and polarization voltage values. Measurements were performed in a Truebeam Linac using FF and FFF modalities. Dose-per-pulse and pulse repetition frequency have been obtained by monitoring the target current with an oscilloscope. Experimental collection efficiencies have been obtained by using a combination of the two-dose-rate method and ratios to the readout of a reference chamber (CC13, IBA). The authors have also used numerical simulation to complement the experimental data. Results: The authors have found that overlap significantly increases recombination in LICs, as expected. However, the functional dependence of collection efficiencies on the dose-per-pulse does not change (a linear dependence has been observed in the near-saturation region for different degrees of overlapping, the same dependence observed in the nonoverlapping scenario). On the other hand, the dependence of collection efficiencies on the polarization voltage changes in the overlapping scenario and does not follow that of Boag equation, the reason being that changing the polarization voltage also affects the charge collection time, thus changing the amount of overlapping. Conclusions: These results have important consequences for saturation correction methods for LICs. On one hand, the two-dose-rate method, which relies on the functional dependence of the collection efficiencies on dose-per-pulse, can also be used in the overlapping situation, provided that the two measurements needed to feed the method are performed at the same pulse repetition frequency (monitor unit rate). This result opens the door to computing collection efficiencies in LICs in many clinical setups where charge overlap in the LIC exists. On the other hand, correction methods based on the voltage-dependence of Boag equation like the three-voltage method or the modified two-voltage method will not work in the overlapping scenario due to the different functional dependence of collection efficiencies on the polarization voltage.« less

  17. SU-F-T-279: Impact of Beam Energy Drifts On IMRT Delivery Accuracy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goddu, S; Kamal, G; Herman, A

    Purpose: According to TG-40 percent-depth-dose (PDD) tolerance is ±2% but TG-142 is ±1%. Now the question is, which one is relevant in IMRT era? The primary objective of this study is to evaluate dosimetric impact of beam-energy-drifts on IMRT-delivery. Methods: Beam-energy drifts were simulated by adjusting Linac’s bending-magnet-current (BMC) followed by tuning the pulse-forming network and adjusting gun-current. PDD change of −0.6% and +1.2% were tested. Planar-dosimetry measurements were performed using an ionization-chamber-array in solid-water phantoms. Study includes 10-head-and-neck and 3-breast cancer patients. en-face beam-deliveries were also tested at 1.3cm and 5.3cm depths. Composite and single-field dose-distributions were compared againstmore » the plans to determine %Gamma pass-rates (%GPRs). For plan dose comparisons, changes in %Gamma pass-rates (cPGPRs) were computed/reported to exclude the differences between dose-computation and delivery. Dose distributions of the drifted-energies were compared against their baseline measurements to determine the% GPRs. A Gamma criteria of 3%/3mm was considered for plan-dose comparisons while 3%/1mm used for measured dose intercomparisons. Results: For composite-dose delivery, average cPGPRs were 0.41%±2.48% and −2.54%±3.65% for low-energy (LE) and high-energy (HE) drifts, respectively. For measured dose inter-comparisons, the average%GPRs were 98.4%±2.2% (LE-drift) and 95.8%±4.0 (HE-drift). The average %GPR of 92.6%±4.3% was noted for the worst-case scenario comparing LE-drift to HE-drift. All en-face beams at 5.3 cm depth have cPGPRs within ±4% of the baseline-energy measurements. However, greater variations were noted for 1.3cm depth. Average %GPRs for drifted energies were >99% at 5.3cm and >97% at 1.3cm depths. However, for the worst-case scenario (LE-drift to HE-drift) these numbers dropped to 95.2% at 5.3cm and 93.1% at 1.3cm depths. Conclusion: The dosimetric impact of beam-energy drifts was found to be within clinically acceptable tolerance. However, this study includes a single energy with limited range of PDD change. Further studies are on going and the results will be presented. Received funding from Varian Medical Systems, Palo Alto, CA.« less

  18. Rapid Acute Dose Assessment Using MCNP6

    NASA Astrophysics Data System (ADS)

    Owens, Andrew Steven

    Acute radiation doses due to physical contact with a high-activity radioactive source have proven to be an occupational hazard. Multiple radiation injuries have been reported due to manipulating a radioactive source with bare hands or by placing a radioactive source inside a shirt or pants pocket. An effort to reconstruct the radiation dose must be performed to properly assess and medically manage the potential biological effects from such doses. Using the reference computational phantoms defined by the International Commission on Radiological Protection (ICRP) and the Monte Carlo N-Particle transport code (MCNP6), dose rate coefficients are calculated to assess doses for common acute doses due to beta and photon radiation sources. The research investigates doses due to having a radioactive source in either a breast pocket or pants back pocket. The dose rate coefficients are calculated for discrete energies and can be used to interpolate for any given energy of photon or beta emission. The dose rate coefficients allow for quick calculation of whole-body dose, organ dose, and/or skin dose if the source, activity, and time of exposure are known. Doses are calculated with the dose rate coefficients and compared to results from the International Atomic Energy Agency (IAEA) reports from accidents that occurred in Gilan, Iran and Yanango, Peru. Skin and organ doses calculated with the dose rate coefficients appear to agree, but there is a large discrepancy when comparing whole-body doses assessed using biodosimetry and whole-body doses assessed using the dose rate coefficients.

  19. AREA RADIATION MONITOR

    DOEpatents

    Manning, F.W.; Groothuis, S.E.; Lykins, J.H.; Papke, D.M.

    1962-06-12

    S>An improved area radiation dose monitor is designed which is adapted to compensate continuously for background radiation below a threshold dose rate and to give warning when the dose integral of the dose rate of an above-threshold radiation excursion exceeds a selected value. This is accomplished by providing means for continuously charging an ionization chamber. The chamber provides a first current proportional to the incident radiation dose rate. Means are provided for generating a second current including means for nulling out the first current with the second current at all values of the first current corresponding to dose rates below a selected threshold dose rate value. The second current has a maximum value corresponding to that of the first current at the threshold dose rate. The excess of the first current over the second current, which occurs above the threshold, is integrated and an alarm is given at a selected integrated value of the excess corresponding to a selected radiation dose. (AEC)

  20. Method to determine the position-dependant metal correction factor for dose-rate equivalent laser testing of semiconductor devices

    DOEpatents

    Horn, Kevin M.

    2013-07-09

    A method reconstructs the charge collection from regions beneath opaque metallization of a semiconductor device, as determined from focused laser charge collection response images, and thereby derives a dose-rate dependent correction factor for subsequent broad-area, dose-rate equivalent, laser measurements. The position- and dose-rate dependencies of the charge-collection magnitude of the device are determined empirically and can be combined with a digital reconstruction methodology to derive an accurate metal-correction factor that permits subsequent absolute dose-rate response measurements to be derived from laser measurements alone. Broad-area laser dose-rate testing can thereby be used to accurately determine the peak transient current, dose-rate response of semiconductor devices to penetrating electron, gamma- and x-ray irradiation.

  1. Clomiphene Stair-Step Protocol for Women With Polycystic Ovary Syndrome.

    PubMed

    Jones, Tiffanny; Ho, Jacqueline R; Gualtieri, Marc; Bruno-Gaston, Janet; Chung, Karine; Paulson, Richard J; Bendikson, Kristin A

    2018-01-01

    To compare time to ovulation, ovulation rates, and side effect profile of traditional and the stair-step protocol for ovulation induction using clomiphene citrate in women with polycystic ovary syndrome (PCOS). We performed a retrospective study of women seeking care for infertility with a diagnosis of PCOS at a university-based infertility clinic from July 2012 to July 2014. We included patients who were resistant to the initial starting dose of 50 mg clomiphene. The primary outcome was time to ovulation. Secondary outcomes included ovulation rates, clinical pregnancy rates, and mild and moderate-to-severe side effects based on dose. For the traditional protocol, higher doses of clomiphene were used each subsequent month if no ovulation occurred. For the stair-step protocol, higher doses of clomiphene were given 7 days after the last dose if no dominant follicles were seen on ultrasonography. Our study had 80% power to detect a 20% difference in ovulation. One hundred nine patients were included in the analysis with 66 (60.6%) in the traditional and 43 (39.4%) in the stair-step protocol. Age and body mass index were similar between groups. The time to ovulation was decreased in the stair-step protocol group compared with the traditional protocol group (23.1±0.9 days vs 47.5±6.3 days). Ovulation rates were increased in the stair-step group compared with the traditional group at 150 mg (16 [37%] vs 8 [12%], P=.004) and at 200 mg (9 [21%] vs 3 [5%], P=.01). Pregnancy rates were similar between groups once ovulation was achieved (12 [18.1%] vs 7 [16.3%], P=.08). The stair-step protocol had an increased incidence of mild side effects (vasomotor flushes, headaches, gastrointestinal disturbance, mastalgia, changes in mood; 18 [41%] vs 8 [12%]), but there was no difference in the incidence of severe side effects (headaches, visual disturbances). For women with PCOS, the stair-step clomiphene protocol is associated with decreased time to ovulation and increased ovulation rates at higher doses when compared with the traditional protocol.

  2. Human Papillomavirus Vaccine Coverage and Prevalence of Missed Opportunities for Vaccination in an Integrated Healthcare System.

    PubMed

    Irving, Stephanie A; Groom, Holly C; Stokley, Shannon; McNeil, Michael M; Gee, Julianne; Smith, Ning; Naleway, Allison L

    2018-03-01

    Human papillomavirus (HPV) vaccination has been recommended in the United States for female and male adolescents since 2006 and 2011, respectively. Coverage rates are lower than those for other adolescent vaccines. The objective of this study was to evaluate an assessment and feedback intervention designed to increase HPV vaccination coverage and quantify missed opportunities for HPV vaccine initiation at preventive care visits. We examined changes in HPV vaccination coverage and missed opportunities within the adolescent (11-17 years) population at 9 Oregon-based Kaiser Permanente Northwest outpatient clinics after an assessment and feedback intervention. Quarterly coverage rates were calculated for the adolescent populations at the clinics, according to age group (11-12 and 13-17 years), sex, and department (Pediatrics and Family Medicine). Comparison coverage assessments were calculated at 3 nonintervention (control) clinics. Missed opportunities for HPV vaccine initiation, defined as preventive care visits in which a patient eligible for HPV dose 1 remained unvaccinated, were examined according to sex and age group. An average of 29,021 adolescents were included in coverage assessments. Before the intervention, 1-dose and 3-dose quarterly coverage rates were increasing at intervention as well as at control clinics in both age groups. Postimplementation quarterly trends in 1-dose or 3-dose coverage did not differ significantly between intervention and control clinics for either age group. One-dose coverage rates among adolescents with Pediatrics providers were significantly higher than those with Family Medicine providers (56% vs 41% for 11- to 12-year-old and 82% vs 69% for 13- to 17-year-old girls; 55% vs 40% for 11- to 12-year-old and 78% vs 62% for 13- to 17-year-old boys). No significant differences in HPV vaccine coverage were identified at intervention clinics. However, coverage rates were increasing before the start of the intervention and might have been influenced by ongoing health system best practices. HPV vaccine coverage rates varied significantly according to department, which could allow for targeted improvement opportunities. Copyright © 2017 Academic Pediatric Association. All rights reserved.

  3. An 8-Week Randomized, Double-Blind Trial Comparing Efficacy, Safety, and Tolerability of 3 Vilazodone Dose-Initiation Strategies Following Switch From SSRIs and SNRIs in Major Depressive Disorder

    PubMed Central

    Rele, Shilpa; Millet, Robert; Kim, Sungman; Paik, Jong-Woo; Kim, Seonghwan; Masand, Prakash S.

    2015-01-01

    Introduction: Vilazodone, a selective and potent 5-HT1A partial agonist and 5-HT reuptake inhibitor, has been approved for treatment of major depressive disorder (MDD) in adults. The primary objective of the study was to compare the efficacy and tolerability of switching to 3 different doses of vilazodone from an equivalent dose range of generic selective serotonin reuptake inhibitors (SSRIs) or serotonin-norepinephrine reuptake inhibitors (SNRIs) in adult subjects with MDD. Method: This was an 8-week, randomized, double-blind, parallel-group, 3-arm trial to compare vilazodone 10 mg/d, 20 mg/d, and 40 mg/d as starting doses. Data were collected from December 2012 to December 2013. There was no washout phase, prior medications were stopped at the baseline visit, and vilazodone was started the next day in adults with MDD (DSM-IV criteria). The 10-mg/d and 20-mg/d dose was increased to 40 mg/d by week 3 and week 1, respectively, and the 40-mg/d initiation dose continued unchanged. The primary efficacy measure was change in Montgomery-Asberg Depression Rating Scale (MADRS) score between the 3 dose groups. The secondary efficacy measures were changes in Clinical Global Impressions–Severity (CGI-S), CGI-Improvement (CGI-I), and Hamilton Anxiety Rating Scale (HARS) scores. Safety measures were obtained by spontaneously reported adverse events, vital signs recording, and laboratory tests. Multivariate tests were used for statistical analysis. Results: Seventy subjects were randomized, and 60 subjects completed the study (n = 20 in each group). Overall, there was a significant reduction in MADRS score from baseline (26.08 ± 1.1) to week 8 (9.86 ± 1.2) in the entire sample (P < .001). Similarly, there was a significant improvement in CGI-S (P < .001), CGI-I (P < .001) and HDRS (P < .001) scores from baseline to the end of the trial. There were no significant differences between the 3 vilazodone dose-initiation groups in changes in MADRS scores (P = .95) or changes in CGI-S (P = .83), CGI-I (P = .51), or HARS scores (P = .61). Dry mouth (n = 55), nausea (n = 10), and diarrhea (n = 5) were the most common side effects, with diarrhea reported in 5 subjects in the 40-mg/d initiation group. No serious adverse events were reported. Conclusions: The present study indicates the potential benefit of switching to vilazodone in patients with MDD who are inadequate responders to SSRIs or SNRIs. There were no meaningful differences in efficacy or tolerability between the 3 different dose-initiation strategies with vilazodone; however, diarrhea appeared to be more frequently reported with the 40-mg/d dose. Given the modest sample size, larger studies are required to confirm our findings. Trial Registration: ClinicalTrials.gov identifiers: NCT02015546 and NCT01473381 PMID:26693034

  4. Temporal trends in treatment and subsequent neoplasm risk among five-year survivors of childhood cancer, 1970-2015

    PubMed Central

    Turcotte, Lucie M.; Liu, Qi; Yasui, Yutaka; Arnold, Michael A.; Hammond, Sue; Howell, Rebecca M.; Smith, Susan A.; Weathers, Rita E.; Henderson, Tara O.; Gibson, Todd M.; Leisenring, Wendy; Armstrong, Gregory T.; Robison, Leslie L; Neglia, Joseph P.

    2017-01-01

    Importance Cancer treatments are associated with subsequent neoplasms in childhood cancer survivors. It is unknown whether temporal changes in therapy are associated with changes in subsequent neoplasm risk. Objective Quantify the association between temporal treatment dosing changes and subsequent neoplasm risk. Design, Setting, Participants Retrospective, multicenter cohort of five-year cancer survivors diagnosed before age 21 years from pediatric tertiary hospitals in the United States and Canada between 1970-1999, with follow-up through December 2015. Exposures Radiation and chemotherapy dose changes over time. Main Outcomes and Measures Subsequent neoplasm 15-year cumulative incidence, cumulative burden, and standardized incidence ratios (SIRs) for subsequent malignancies were compared by treatment decade. Multivariable models assessed relative rates (RRs) of subsequent neoplasms by 5-year increments, adjusting for demographic and clinical characteristics. Mediation analyses assessed whether changes in subsequent neoplasm rates over time were mediated by treatment variable modifications. Results Among 23,603 childhood cancer survivors (mean age at diagnosis, 7.7 years; 46% female) the most common initial diagnoses were acute lymphoblastic leukemia, Hodgkin lymphoma and astrocytoma. During a mean follow up of 20.5 years (374,638 person-years at risk), 1,639 survivors experienced 3,115 subsequent neoplasms, including 1,026 malignancies, 233 benign meningiomas, and 1,856 non-melanoma skin cancers. The most common subsequent malignancies were breast and thyroid cancers. Individuals receiving radiation decreased (1970s, 77% vs. 1990s, 33%), as did median dose (1970s, 30 Gy [IQR 24-44] vs. 1990s, 26 Gy [IQR 18-45]). Fifteen-year cumulative incidence of subsequent malignancies decreased by decade of diagnosis (1990s: 1.3%, 95%CI 1.1-1.5, 1980s: 1.7%, 95%CI 1.5-2.0, 1970s: 2.1%, 95%CI 1.7-2.4). Reference absolute rates per 1,000 person-years for subsequent malignancies, meningiomas and non-melanoma skin cancers were 1.12 (95%CI 0.84-1.57), 0.16 (95%CI 0.06-0.41), and 1.71 (95%CI 0.88-3.33), respectively, for survivors with reference characteristics (no chemotherapy, splenectomy or radiation therapy, male, attained age of 28). SIRs declined for subsequent malignancies over treatment decades, with advancing attained age. Relative rates declined with each 5-year increment for subsequent malignancies (RR=0.87, 95%CI 0.82-0.93, p<0.001), meningiomas (RR=0.85, 95%CI 0.75-0.97, p=0.034), and non-melanoma skin cancers (RR=0.75, 95%CI 0.67-0.84, p<0.001). Radiation dose changes were associated with reduced risk for subsequent malignancies, meningiomas, and non-melanoma skin cancers. Conclusions and Relevance Among childhood cancer survivors, the risk of subsequent malignancies at 15 years after initial cancer diagnosis remained increased for those diagnosed in the 1990s, although the risk was lower compared with those diagnosed in the 1970s. This lower risk was associated with reduction in therapeutic radiation dose. PMID:28245323

  5. Impact of the Amount of Liquid Intake on the Dose Rate of Patients Treated with Radioiodine.

    PubMed

    Haghighatafshar, Mahdi; Banani, Aida; Zeinali-Rafsanjani, Banafsheh; Etemadi, Zahra; Ghaedian, Tahereh

    2018-01-01

    Despite therapeutic effects of radioiodine in patients with differentiated thyroid cancer, there are some disadvantages due to harmful radiation to other tissues. According to the current guidelines, patients are recommended to drink lots of water and frequent voiding to reduce the amount of 131 I in the body. This study was designed to assess the impact of the amount of liquid intake on reduction of the measured dose rate of radioiodine-treated patients. A total of 42 patients with differentiated thyroid cancer without metastasis who had undergone total thyroidectomy and had been treated with radioiodine were selected. The patients were divided into two groups according to the amount of their fluid intake which was measured during the first 48 h after 131 I administration. In all patients, the dose rate was measured immediately and 48 h after iodine administration. Each group included 21 patients. Dose rate ratio (the ratio of the second dose rate to the first dose rate) and dose rate difference ratio (the ratio of the difference between the two measured dose rates to the first dose rate) were calculated for each patient. Despite the significant difference in the amount of the liquid drunk, no statistically significant difference was seen between the different groups in parameters of dose-rate ratio and dose-rate difference ratio. Higher fluid intake (>60 ml/h in our study) alone would not effectively reduce the patient's radiation dose rate at least not more than a well-hydrated state. It seems that other interfering factors in the thyroidectomized patients may also have some impacts on this physiologic process.

  6. Caudate neuronal recording in freely behaving animals following acute and chronic dose response methylphenidate exposure

    PubMed Central

    Claussen, Catherine M; Dafny, Nachum

    2016-01-01

    The misuse and abuse of the psychostimulant, methylphenidate (MPD) the drug of choice in the treatment of attention deficit hyperactivity disorder (ADHD) has seen a sharp uprising in recent years among both youth and adults for its cognitive enhancing effects and for recreational purposes. This uprise in illicit use has lead to many questions concerning the long term consequences of MPD exposure. The objective of this study was to record animal behavior concomitantly with the caudate nucleus (CN) neuronal activity following acute and repetitive (chronic) dose response exposure to methylphenidate (MPD). A saline control and three MPD dose (0.6, 2.5, and 10.0 mg/kg) groups were used. Behaviorally, the same MPD dose in some animals following chronic MPD exposure elicited behavioral sensitization and other animals elicited behavioral tolerance. Based on this finding, the CN neuronal population recorded from animals expressing behavioral sensitization were also evaluated separately from CN neurons recorded from animals expressing behavioral tolerance to chronic MPD exposure, respectively. Significant differences in CN neuronal population responses between the behaviorally sensitized and the behaviorally tolerant animals was observed for the 2.5 and 10.0 mg/kg MPD exposed groups. For 2.5 mg/kg MPD, behaviorally sensitized animals responded by decreasing their firing rates while behaviorally tolerant animals showed mainly an increase in their firing rates. The CN neuronal responses recorded from the behaviorally sensitized animals following 10.0 mg/kg MPD responded by increasing their firing rates whereas the CN neuronal recordings from the behaviorally tolerant animals showed that approximately half decreased their firing rates in response to 10.0 mg/kg MPD exposure. The comparison of percentage change in neuronal firing rates showed that the behaviorally tolerant animals trended to exhibit increases in their neuronal firing rates at ED1 following initial MPD exposure and oppositely at ED10 MPD rechallenge. While the behaviorally sensitized animals in general increased in their percentage change of firing rats were observed following acute 10.0 mg/kg MPD and the behaviorally sensitized 10.0 mg/kg MPD animals and a robust increase in neuronal firing rates at ED1 and ED10 rechallenge. These results suggest the need to first individually analyze animal behavioral activity, and than to evaluate the neuronal responses to the drug based on the animals behavioral response to chronic MPD exposure. PMID:26101057

  7. Cardiovascular tolerance of intravenous bupivacaine in broiler chickens (Gallus gallus domesticus) anesthetized with isoflurane.

    PubMed

    DiGeronimo, Peter M; da Cunha, Anderson F; Pypendop, Bruno; Brandão, João; Stout, Rhett; Rinaldi, Max; Tully, Thomas N

    2017-03-01

    To determine the median effective dose (ED 50 ) of intravenous (IV) bupivacaine associated with a 50% probability of causing clinically relevant cardiovascular effects [defined as 30% change in heart rate (HR) or mean arterial pressure (MAP)] in chickens anesthetized with isoflurane. Randomized up-and-down study. A total of 14 Ross-708 broiler chickens (Gallus gallus domesticus) weighing 1.70-2.75 kg. Anesthesia was induced and maintained with isoflurane. Monitoring included the electrocardiogram and invasive arterial pressures. Chickens were administered bupivacaine IV over 2 minutes using a dose based on the response of the previous animal. Dose was decreased when HR and/or MAP in the previous animal increased or decreased ≥30% after bupivacaine administration, or increased when HR or MAP changed <30%. The ED 50 was defined as the dose resulting in ≥30% variation in HR or MAP in 50% of the population studied. The IV ED 50 of bupivacaine was 1.94 mg kg -1 using Dixon's up-and-down method and 1.96 mg kg -1 by logistic regression. These results suggest that 1.33 and 1.96 mg kg -1 of IV bupivacaine are associated with a respective 1 or 50% probability of a clinically significant change in MAP in isoflurane-anesthetized chickens. Identification of the cardiovascular changes associated with different doses of bupivacaine can be used as the basis for studies of therapeutic applications in the domestic chicken. Further studies are required to determine interspecies variation. Published by Elsevier Ltd.

  8. Recommended de minimis radiation dose rates for Canada. Report No. INFO-0355

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-01-01

    A de minimis dose or dose rate as used in this report represents a level of risk which is generally accepted as being of no significance to an individual, or in the case of a population, of no significance to society. The report describes the risk of biological effects from radiation; radiation from natural and man-made sources; normal incidences of cancer and genetic defects; initiatives by other agencies in the U.S., the U.K. and internationally; the importance of collective dose and dose rate; assigning values to the de minimis dose rates; and application of the de minimis dose rates.

  9. Radiobiological equivalent of low/high dose rate brachytherapy and evaluation of tumor and normal responses to the dose.

    PubMed

    Manimaran, S

    2007-06-01

    The aim of this study was to compare the biological equivalent of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy in terms of the more recent linear quadratic (LQ) model, which leads to theoretical estimation of biological equivalence. One of the key features of the LQ model is that it allows a more systematic radiobiological comparison between different types of treatment because the main parameters alpha/beta and micro are tissue-specific. Such comparisons also allow assessment of the likely change in the therapeutic ratio when switching between LDR and HDR treatments. The main application of LQ methodology, which focuses on by increasing the availability of remote afterloading units, has been to design fractionated HDR treatments that can replace existing LDR techniques. In this study, with LDR treatments (39 Gy in 48 h) equivalent to 11 fractions of HDR irradiation at the experimental level, there are increasing reports of reproducible animal models that may be used to investigate the biological basis of brachytherapy and to help confirm theoretical predictions. This is a timely development owing to the nonavailability of sufficient retrospective patient data analysis. It appears that HDR brachytherapy is likely to be a viable alternative to LDR only if it is delivered without a prohibitively large number of fractions (e.g., fewer than 11). With increased scientific understanding and technological capability, the prospect of a dose equivalent to HDR brachytherapy will allow greater utilization of the concepts discussed in this article.

  10. Validating the Effectiveness of Switching the Vancomycin TDM Analysis Software Based on the Predictive Accuracy.

    PubMed

    Imai, Shungo; Yamada, Takehiro; Ishiguro, Nobuhisa; Miyamoto, Takenori; Kagami, Keisuke; Tomiyama, Naoki; Niinuma, Yusuke; Nagasaki, Daisuke; Suzuki, Koji; Yamagami, Akira; Kasashi, Kumiko; Kobayashi, Masaki; Iseki, Ken

    2017-01-01

    Based on the predictive performance in our previous study, we switched the therapeutic drug monitoring (TDM) analysis software for dose setting of vancomycin (VCM) from "Vancomycin MEEK TDM analysis software Ver2.0" (MEEK) to "SHIONOGI-VCM-TDM ver.2009" (VCM-TDM) in January 2015. In the present study, our aim was to validate the effectiveness of the changing VCM TDM analysis software in initial dose setting of VCM. The enrolled patients were divided into two groups, each having 162 patients in total, who received VCM with the initial dose set using MEEK (MEEK group) or VCM-TDM (VCM-TDM group). We compared the rates of attaining the therapeutic range (trough value; 10-20 μg/mL) of serum VCM concentration between the groups. Multivariate logistic regression analysis was performed to confirm that changing the VCM TDM analysis software was an independent factor related to attaining the therapeutic range. Switching the VCM TDM analysis software from MEEK to VCM-TDM improved the rate of attaining the therapeutic range by 21.6% (MEEK group: 42.6% vs. VCM-TDM group: 64.2%, p<0.01). Patient age ≥65 years, concomitant medication (furosemide) and the TDM analysis software used VCM-TDM were considered to be independent factors for attaining the therapeutic range. These results demonstrated the effectiveness of switching the VCM TDM analysis software from MEEK to VCM-TDM for initial dose setting of VCM.

  11. Changes in dialysis treatment modalities during institution of flat rate reimbursement and quality assurance programs.

    PubMed

    Kleophas, Werner; Karaboyas, Angelo; Li, Yun; Bommer, Juergen; Reichel, Helmut; Walter, Andreas; Icks, Andrea; Rump, Lars C; Pisoni, Ronald L; Robinson, Bruce M; Port, Friedrich K

    2013-09-01

    Dialysis procedure rates in Germany were changed in 2002 from per-session to weekly flat rate payments, and quality assurance was introduced in 2009 with defined treatment targets for spKt/V, dialysis frequency, treatment time, and hemoglobin. In order to understand trends in treatment parameters before and after the introduction of these changes, we analyzed data from 407 to 618 prevalent patients each year (hemodialysis over 90 days) in 14-21 centers in cross-sections of the Dialysis Outcomes and Practice Patterns Study (phases 1-4, 1998-2011). Descriptive statistics were used to report differences over time in the four quality assurance parameters along with erythropoietin-stimulating agent (ESA) and intravenous iron doses. Time trends were analyzed using linear mixed models adjusted for patient demographics and comorbidities. The proportion of patients with short treatment times (less than 4 h) and low spKt/V (below 1.2) improved throughout the study and was lowest after implementation of quality assurance. Hemoglobin levels have increased since 1998 and remained consistent since 2005, with only 8-10% of patients below 10 g/dl. About 90% of patients were prescribed ESAs, with the dose declining since peaking in 2006. Intravenous iron use was highest in 2011. Hence, trends to improve quality metrics for hemodialysis have been established in Germany even after introduction of flat rate reimbursement. Thus, analysis of facility practice patterns is needed to maintain quality of care in a cost-containment environment.

  12. Subjective and physiological effects, and expired carbon monoxide concentrations in frequent and occasional cannabis smokers following smoked, vaporized, and oral cannabis administration.

    PubMed

    Newmeyer, Matthew N; Swortwood, Madeleine J; Abulseoud, Osama A; Huestis, Marilyn A

    2017-06-01

    Although smoking is the most common cannabis administration route, vaporization and consumption of cannabis edibles are common. Few studies directly compare cannabis' subjective and physiological effects following multiple administration routes. Subjective and physiological effects, and expired carbon monoxide (CO) were evaluated in frequent and occasional cannabis users following placebo (0.001% Δ 9 -tetrahydrocannabinol [THC]), smoked, vaporized, and oral cannabis (6.9% THC, ∼54mg). Participants' subjective ratings were significantly elevated compared to placebo after smoking and vaporization, while only occasional smokers' ratings were significantly elevated compared to placebo after oral dosing. Frequent smokers' maximum ratings were significantly different between inhaled and oral routes, while no differences in occasional smokers' maximum ratings between active routes were observed. Additionally, heart rate increases above baseline 0.5h after smoking (mean 12.2bpm) and vaporization (10.7bpm), and at 1.5h (13.0bpm) and 3h (10.2bpm) after oral dosing were significantly greater than changes after placebo, with no differences between frequent and occasional smokers. Finally, smoking produced significantly increased expired CO concentrations 0.25-6h post-dose compared to vaporization. All participants had significant elevations in subjective effects after smoking and vaporization, but only occasional smokers after oral cannabis, indicating partial tolerance to subjective effects with frequent exposure. There were no differences in occasional smokers' maximum subjective ratings across the three active administration routes. Vaporized cannabis is an attractive alternative for medicinal administrations over smoking or oral routes; effects occur quickly and doses can be titrated with minimal CO exposure. These results have strong implications for safety and abuse liability assessments. Published by Elsevier B.V.

  13. Study of the dose rate effect of 180 nm nMOSFETs

    NASA Astrophysics Data System (ADS)

    He, Bao-Ping; Yao, Zhi-Bin; Sheng, Jiang-Kun; Wang, Zu-Jun; Huang, Shao-Yan; Liu, Min-Bo; Xiao, Zhi-Gang

    2015-01-01

    Radiation induced offstate leakage in the shallow trench isolation regions of SIMC 0.18 μm nMOSFETs is studied as a function of dose rate. A “true” dose rate effect (TDRE) is observed. Increased damage is observed at low dose rate (LDR) than at high dose rate (HDR) when annealing is taken into account. A new method of simulating radiation induced degradation in shallow trench isolation (STI) is presented. A comparison of radiation induced offstate leakage current in test nMOSFETs between total dose irradiation experiments and simulation results exhibits excellent agreement. The investigation results imply that the enhancement of the leakage current may be worse for the dose rate encountered in the environment of space.

  14. TU-G-BRD-08: In-Vivo EPID Dosimetry: Quantifying the Detectability of Four Classes of Errors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ford, E; Phillips, M; Bojechko, C

    Purpose: EPID dosimetry is an emerging method for treatment verification and QA. Given that the in-vivo EPID technique is in clinical use at some centers, we investigate the sensitivity and specificity for detecting different classes of errors. We assess the impact of these errors using dose volume histogram endpoints. Though data exist for EPID dosimetry performed pre-treatment, this is the first study quantifying its effectiveness when used during patient treatment (in-vivo). Methods: We analyzed 17 patients; EPID images of the exit dose were acquired and used to reconstruct the planar dose at isocenter. This dose was compared to the TPSmore » dose using a 3%/3mm gamma criteria. To simulate errors, modifications were made to treatment plans using four possible classes of error: 1) patient misalignment, 2) changes in patient body habitus, 3) machine output changes and 4) MLC misalignments. Each error was applied with varying magnitudes. To assess the detectability of the error, the area under a ROC curve (AUC) was analyzed. The AUC was compared to changes in D99 of the PTV introduced by the simulated error. Results: For systematic changes in the MLC leaves, changes in the machine output and patient habitus, the AUC varied from 0.78–0.97 scaling with the magnitude of the error. The optimal gamma threshold as determined by the ROC curve varied between 84–92%. There was little diagnostic power in detecting random MLC leaf errors and patient shifts (AUC 0.52–0.74). Some errors with weak detectability had large changes in D99. Conclusion: These data demonstrate the ability of EPID-based in-vivo dosimetry in detecting variations in patient habitus and errors related to machine parameters such as systematic MLC misalignments and machine output changes. There was no correlation found between the detectability of the error using the gamma pass rate, ROC analysis and the impact on the dose volume histogram. Funded by grant R18HS022244 from AHRQ.« less

  15. Cardiohemodynamic and electrophysiological effects of a selective EP4 receptor agonist ONO--AE1--329 in the halothane-anesthetized dogs.

    PubMed

    Nomura, Hiroaki; Nakamura, Yuji; Cao, Xin; Honda, Atsushi; Katagi, Jun; Ohara, Hiroshi; Izumi-Nakaseko, Hiroko; Satoh, Yoshioki; Ando, Kentaro; Sugiyama, Atsushi

    2015-08-15

    Cardiovascular effects of a highly selective prostaglandin E2 type 4 (EP4) receptor agonist ONO-AE1-329 were assessed with the halothane-anesthetized dogs (n=6). ONO-AE1-329 was intravenously infused in three escalating doses of 0.3, 1 and 3ng/kg/min for 10min with a pause of 20min between the doses. The low dose of 0.3ng/kg/min significantly increased maximum upstroke velocity of left ventricular pressure by 18% at 20min, indicating increase of ventricular contractility. The middle dose of 1ng/kg/min significantly decreased total peripheral resistance by 24% and left ventricular end-diastolic pressure by 32% at 10min, indicating dilation of arteriolar resistance vessels and venous capacitance ones, respectively; and increased cardiac output by 25% at 10min in addition to the change induced by the low dose. The high dose of 3ng/kg/min increased heart rate by 34% at 10min; decreased mean blood pressure by 14% at 10min and atrioventricular nodal conduction time by 13% at 5min; and shortened left ventricular systolic period by 8% at 10min and electromechanical coupling defined as an interval from completion of repolarization to the start of ventricular diastole by 39% at 10min in addition to the changes induced by the middle dose. No significant change was detected in a ventricular repolarization period. These results indicate that ONO-AE1-329 may possess a similar cardiovascular profile to typical phosphodiesterase 3 inhibitors as an inodilator, and suggest that EP4 receptor stimulation can become an alternative strategy for the treatment of congestive heart failure. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J., E-mail: edwardc@schoolph.uma

    This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report'smore » Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.« less

  17. Effects of Different Doses of Irbesartan Combined With Spironolactone on Urinary Albumin Excretion Rate in Elderly Patients With Early Type 2 Diabetic Nephropathy.

    PubMed

    Chen, Yingying; Liu, Peng; Chen, Xia; Li, Yanan; Zhang, Fengmei; Wang, Yangang

    2018-05-01

    There is a lack of research on the effect of low dose of angiotensin receptor blockers combined with spironolactone, and the effect of high dose of angiotensin receptor blockers alone on the urinary albumin excretion rate (UAER) in elderly patients with early type 2 diabetic nephropathy (DN). We conducted a prospective, randomized, open-label, parallel-controlled study that included 244 elderly patients with early DN and mild-to-moderate essential hypertension. Patients were randomly divided into 4 groups: low-dose irbesartan (group A), high-dose irbesartan (group B), low-dose irbesartan combined with spironolactone (group C) and high-dose irbesartan combined with spironolactone (group D). Changes in UAER, serum potassium and blood pressure were compared. There were no statistical differences in the baseline characteristics among groups. Furthermore, no significant difference in blood pressure before and after treatment was found among different groups. After 72-week treatment, UAER in group D was lower compared to group A and B (P < 0.05). Meanwhile, compared with group B, UAER in group C decreased significantly (P < 0.05). Additionally, significantly higher serum potassium was found in group D compared to other groups (P < 0.05). Also, group D had the highest count of patients who withdrew from the study due to hyperkalemia compared to other groups (P < 0.05). Our results indicate high-dose irbesartan combined with spironolactone may be more efficient in reducing UAER in elderly patients with early DN, but this treatment could cause hyperkalemia. Low-dose irbesartan combined with spironolactone was shown to be safer and more effective in decreasing UAER compared to high-dose irbesartan. Copyright © 2018 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  18. Intensity-Modulated Radiotherapy of Head and Neck Cancer Aiming to Reduce Dysphagia: Early Dose-Effect Relationships for the Swallowing Structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Felix Y.; Kim, Hyungjin M.; Lyden, Teresa H.

    2007-08-01

    Purpose: To present initial results of a clinical trial of intensity-modulated radiotherapy (IMRT) aiming to spare the swallowing structures whose dysfunction after chemoradiation is a likely cause of dysphagia and aspiration, without compromising target doses. Methods and Materials: This was a prospective, longitudinal study of 36 patients with Stage III-IV oropharyngeal (31) or nasopharyngeal (5) cancer. Definitive chemo-IMRT spared salivary glands and swallowing structures: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus. Lateral but not medial retropharyngeal nodes were considered at risk. Dysphagia endpoints included objective swallowing dysfunction (videofluoroscopy), and both patient-reported and observer-rated scores. Correlations between dosesmore » and changes in these endpoints from pre-therapy to 3 months after therapy were assessed. Results: Significant correlations were observed between videofluoroscopy-based aspirations and the mean doses to the PC and GSL, as well as the partial volumes of these structures receiving 50-65 Gy; the highest correlations were associated with doses to the superior PC (p = 0.005). All patients with aspirations received mean PC doses >60 Gy or PC V{sub 65} >50%, and GSL V{sub 50} >50%. Reduced laryngeal elevation and epiglottic inversion were correlated with mean PC and GSL doses (p < 0.01). All 3 patients with strictures had PC V{sub 70} >50%. Worsening patient-reported liquid swallowing was correlated with mean PC (p = 0.05) and esophageal (p 0.02) doses. Only mean PC doses were correlated with worsening patient-reported solid swallowing (p = 0.04) and observer-rated swallowing scores (p = 0.04). Conclusions: These dose-volume-effect relationships provide initial IMRT optimization goals and motivate further efforts to reduce swallowing structures doses to reduce dysphagia and aspiration.« less

  19. Comparison of U.S. Environmental Protection Agency’s CAP88 PC versions 3.0 and 4.0

    DOE PAGES

    Jannik, Tim; Farfan, Eduardo B.; Dixon, Ken; ...

    2015-08-01

    The Savannah River National Laboratory (SRNL) with the assistance of Georgia Regents University, completed a comparison of the U.S. Environmental Protection Agency's (EPA) environmental dosimetry code CAP88 PC V3.0 with the recently developed V4.0. CAP88 is a set of computer programs and databases used for estimation of dose and risk from radionuclide emissions to air. At the U.S. Department of Energy's Savannah River Site, CAP88 is used by SRNL for determining compliance with EPA's National Emission Standards for Hazardous Air Pollutants (40 CFR 61, Subpart H) regulations. Using standardized input parameters, individual runs were conducted for each radionuclide within itsmore » corresponding database. Some radioactive decay constants, human usage parameters, and dose coefficients changed between the two versions, directly causing a proportional change in the total effective 137Cs, 3H, 129I, 239Pu, and 90Sr) is provided. In general, the total effective doses will decrease for alpha/beta emitters because of reduced inhalation and ingestion rates in V4.0. However, for gamma emitters, such as 60Co and 137Cs, the total effective doses will increase because of changes EPA made in the external ground shine calculations.« less

  20. Combined effects of methamphetamine and zolpidem on performance and mood during simulated night shift work.

    PubMed

    Hart, Carl L; Haney, Margaret; Nasser, Jennifer; Foltin, Richard W

    2005-07-01

    Individuals who work irregular or rotating shifts often use stimulants and sedatives to offset shift-change-related mood and performance decrements. During this simulated shift work study the acute effects of the stimulant, methamphetamine were examined, and the effects of the hypnotic, zolpidem, and the combination were assessed during the shift after drug administration. Eight volunteers completed this 21-day, within-participant, residential laboratory study during which they received a single oral methamphetamine dose (0 or 10 mg) 1 h after waking, i.e., before task performance, and a single oral zolpidem dose (0 or 10 mg) 1 h before bedtime under 2 shift conditions: day shift and night shift. When participants received placebo at both dosing times, performance on some psychomotor tasks (e.g., the digit-symbol substitution task) and on some measures of mood (e.g., ratings of "Energetic") were disrupted during the night shift, relative to the day shift. Methamphetamine alone eliminated virtually all shift-related disruptions, while zolpidem alone and the drug combination produced few effects. These data indicate that shift changes produce performance impairments and mood alterations that are improved by a single low to moderate dose of methamphetamine. Zolpidem, given alone or in combination with methamphetamine, did not alleviate most shift-change mood and performance effects.

  1. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions.

    PubMed

    Straume, T; Braby, L A; Borak, T B; Lusby, T; Warner, D W; Perez-Nunez, D

    2015-10-01

    Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of yD (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with g rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h(-1). Measurements of yD for 200 MeV n(-1) carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%.

  2. Physiological effects following administration of Citrus aurantium for 28 days in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Deborah K., E-mail: deborah.hansen@fda.hhs.gov; George, Nysia I.; White, Gene E.

    Background: Since ephedra-containing dietary supplements were banned from the US market, manufacturers changed their formulations by eliminating ephedra and replacing with other botanicals, including Citrus aurantium, or bitter orange. Bitter orange contains, among other compounds, synephrine, a chemical that is chemically similar to ephedrine. Since ephedrine may have cardiovascular effects, the goal of this study was to investigate the cardiovascular effects of various doses of bitter orange extract and pure synephrine in rats. Method: Female Sprague–Dawley rats were dosed daily by gavage for 28 days with synephrine from two different extracts. One extract contained 6% synephrine, and the other extractmore » contained 95% synephrine. Doses were 10 or 50 mg synephrine/kg body weight from each extract. Additionally, caffeine was added to these doses, since many dietary supplements also contain caffeine. Telemetry was utilized to monitor heart rate, blood pressure, body temperature and QT interval in all rats. Results and conclusion: Synephrine, either as the bitter orange extract or as pure synephrine, increased heart rate and blood pressure. Animals treated with 95% synephrine showed minimal effects on heart rate and blood pressure; more significant effects were observed with the bitter orange extract suggesting that other components in the botanical can alter these physiological parameters. The increases in heart rate and blood pressure were more pronounced when caffeine was added. None of the treatments affected uncorrected QT interval in the absence of caffeine.« less

  3. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions

    PubMed Central

    Straume, T.; Braby, L.A.; Borak, T.B.; Lusby, T.; Warner, D.W.; Perez-Nunez, D.

    2015-01-01

    Abstract Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with γ rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h−1. Measurements of for 200 MeV n−1 carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%. PMID:26313585

  4. A novel and selective sodium-glucose cotransporter-2 inhibitor, tofogliflozin, improves glycaemic control and lowers body weight in patients with type 2 diabetes mellitus.

    PubMed

    Ikeda, S; Takano, Y; Cynshi, O; Tanaka, R; Christ, A D; Boerlin, V; Beyer, U; Beck, A; Ciorciaro, C; Meyer, M; Kadowaki, T

    2015-10-01

    To assess the efficacy, safety and tolerability of different doses of tofogliflozin, a novel, highly selective sodium-glucose cotransporter 2 (SGLT2) inhibitor, in patients with type 2 diabetes mellitus (T2DM). In a 12-week, multicentre, multinational, randomized, double-blind, parallel-group, placebo-controlled, dose-finding study, patients with inadequate glycaemic control from diet and exercise alone, or from diet and exercise plus a stable dose of metformin, were randomized to one of five doses of tofogliflozin (2.5, 5, 10, 20, or 40 mg) or placebo. The primary efficacy endpoint was absolute change at week 12 from baseline in glycated haemoglobin (HbA1c), minus the change in the placebo group. Statistically significant dose-dependent reductions in HbA1c were shown in all treated groups except the 2.5-mg dose group, with a maximum reduction of 0.56% (placebo-subtracted) at the 40-mg dose, along with increased urinary glucose excretion. Metformin treatment had no substantial influence on tofogliflozin efficacy. Dose-dependent reductions in fasting plasma glucose and body weight were observed, and glucose intolerance was improved, with a trend towards blood pressure reduction. Slight increases were observed for mean ketone bodies with no abnormal change in ketone body ratio. No deaths or treatment-related serious adverse events were reported. The incidence of adverse events was similar in the placebo (37.9%) to that in the tofogliflozin group (35.9-46.3%). Withdrawal because of adverse events was rare (≤2 patients per treatment group), with similar rates of withdrawal in the placebo and tofogliflozin groups. A once-daily dose of tofogliflozin for 12 weeks was an effective, safe and well-tolerated treatment for T2DM. © 2015 John Wiley & Sons Ltd.

  5. Enhanced renal prostaglandin production in the dog. I. Effects on renal function.

    PubMed

    Tannenbaum, J; Splawinski, J A; Oates, J A; Nies, A S

    1975-01-01

    The changes in renal function produced by endogenous synthesis of prostaglandins by the kidney were evaluated by infusing sodium arachidonate, the prescursor of the prostaglandins, into one renal artery of the dog. These changes were compared with those produced by similar infusions on performed prostaglandin (PG) E2 and F2alpha.PGE2given at 0.01-0.3 mug/kg min--1 produced dose-related increases in urine flow, sodium and potassium excretion, free water clearance, and renal blood flow. The glomerular filtration rage increased only at the lowest dose and the calculated filtration fraction fell. Arachidonic acid at 1.0-30.0 mug/kg min--1 similarly produced dose-related increases in electrolyte excretion, but the increase in renal blood flow was much less than that produced by PGE2 and there were no changes in glomerular filtration rate, filtration fraction, or free water clearances. PGF2alpha had essentially no effects at infusion rates of 0.03-1.0 mug/kg min--1. All renal effects of arachidonic acid were inhibited by simultaneous infusions of an inhibitor of prostaglandin synthetase, 5, 8, 11,14-eicosatetraynoic acid (20:4). None of the effects produced by PGE2 were inhibited by 20:4. These results indicate that enhanced endogenous renal prostaglandin synthesis, which can be produced by arachidonate infusion, results in significant alterations of renal function. This finding strengthens the hypothesis that renal prostaglandins formed in vivo have physiological importance as regulators of renal function.

  6. Atmospheric radiation flight dose rates

    NASA Astrophysics Data System (ADS)

    Tobiska, W. K.

    2015-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has been conducting space weather observations of the atmospheric radiation environment at aviation altitudes that will eventually be transitioned into air traffic management operations. The Automated Radiation Measurements for Aerospace Safety (ARMAS) system and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) both are providing dose rate measurements. Both activities are under the ARMAS goal of providing the "weather" of the radiation environment to improve aircraft crew and passenger safety. Over 5-dozen ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. Flight altitudes now exceed 60,000 ft. and extend above commercial aviation altitudes into the stratosphere. In this presentation we describe recent ARMAS and USEWX results.

  7. Adjunctive aripiprazole in the treatment of risperidone-induced hyperprolactinemia: A randomized, double-blind, placebo-controlled, dose-response study.

    PubMed

    Chen, Jing-Xu; Su, Yun-Ai; Bian, Qing-Tao; Wei, Li-He; Zhang, Rong-Zhen; Liu, Yan-Hong; Correll, Christoph; Soares, Jair C; Yang, Fu-De; Wang, Shao-Li; Zhang, Xiang-Yang

    2015-08-01

    Hyperprolactinemia is an unwanted adverse effect associated with several antipsychotics. The addition of partial dopamine receptor agonist aripiprazole may attenuate antipsychotic-induced hyperprolactinemia effectively. However, the ideal dosing regimen for this purpose is unknown. We aimed to evaluate the dose effects of adjunctive treatment with aripiprazole on prolactin levels and hyperprolactinemia in schizophrenia patients. Stable subjects 18-45 years old with schizophrenia and hyperprolactinemia (i.e., >24 ng/ml for females and >20 ng/ml for males) were randomly assigned to receive 8 weeks of placebo (n=30) or oral aripiprazole 5mg/day (n=30), 10mg/day (n=29), or 20mg/day (n=30) added on to fixed dose risperidone treatment. Serum prolactin levels were measured at baseline and after 2, 4 and 8 weeks; clinical symptoms and side effects were assessed at baseline and week 8 using the Positive and Negative Syndrome Scale, Clinical Global Impressions Severity scale, Barnes Akathisia Scale, Simpson-Angus Scale and UKU Side Effects Rating Scale. Of 119 randomized patients, 107 (89.9%) completed the 8-week study. At study end, all three aripiprazole doses resulted in significantly lower prolactin levels (beginning at week 2), higher response rates (≥30% prolactin reduction) and higher prolactin normalization rates than placebo. Effects were significantly greater in the 10 and 20mg/day groups than the 5mg/day group. No significant changes were observed in any treatment groups regarding psychopathology and adverse effect ratings. Adjunctive aripiprazole treatment was effective and safe for resolving risperidone-induced hyperprolactinemia, producing significant and almost maximal improvements by week 2 without significant effects on psychopathology and side effects. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Radiation-induced CT number changes in GTV and parotid glands during the course of radiation therapy for nasopharyngeal cancer

    PubMed Central

    Xu, Shouping; Wu, Zhaoxia; Yang, Cungeng; Ma, Lin; Qu, Baolin; Chen, Guangpei; Yao, Weirong; Wang, Shi; Liu, Yaqiang

    2016-01-01

    Objective: To investigate the changes in CT number (CTN) in gross tumour volume (GTV) and organs at risk (OARs) during the course of radiation therapy (RT) for nasopharyngeal cancer (NPC). Methods: Daily megavoltage CT (MVCT) data collected from 30 patients with NPC treated with a prescription dose of 70 Gy in 30–33 fractions using helical tomotherapy were retrospectively analyzed. The contours of GTV and OARs on daily MVCTs were obtained by populating the planning contours from planning CT to daily MVCTs with manual editing, if necessary. The changes of GTV and OAR volumes and the histograms of CTN in the GTV and OARs during the course of RT delivery were analyzed. Results: Volumes of GTV and parotid glands were reduced during the course of radiation treatment, with an average shrinkage rate of 0.23% per day (range, 0.02–0.8%) and 1.2% per day (range, 0.2–2.3%), respectively. The mean CTN changes in GTV and ipsilateral and contralateral parotid glands were reduced by 52 ± 35 HU, 18 ± 20 HU and 17 ± 22 HU, respectively. For GTV, the CTN and GTV volume decreases were found to be correlated with each other (p < 0.0001). No noticeable CTN change was found in the spinal cord and non-specified tissue irradiated with low doses. Conclusion: The CTN changes in GTV and parotids are measurable during the delivery of fractionated radiotherapy for NPC, were associated with the doses received (the number of fractions delivered) and were patient specific. Advances in knowledge: The CTN change during radiotherapy is dose dependent and is measurable for NPC. PMID:27033059

  9. Study of the biochemical indicators of chronic irradiation in rats.

    PubMed

    Szabo, L D; Benko, A B; Gyenge, L; Predmerszky, T

    1976-01-01

    Daily urinary excretion of pseudouridine, creatinine and creatine of chronically irradiated Wistar rats was estimated. The irradiation conditions were: 60Co gamma source, dose-rate 10 rad/day, total dose 200, 400 and 600 rad. Control groups were kept under similar conditions. Urine samples were taken three times after the end of the irradiation period. It was found that: (1) pseudouridine excretion seems more suitable for indicating radiation injury than the creatine/creatinine ratio in chronic irradiation in rats; (ii) there are significant changes in dose dependence of pseudouridine excretion in the post-irradiation period; (iii) a new method for pseudouridine estimation gives closely similar data to those of earlier investigations.

  10. Characterization of a gated fiber-optic-coupled detector for application in clinical electron beam dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanyi, James A.; Nitzling, Kevin D.; Lodwick, Camille J.

    2011-02-15

    Purpose: Assessment of the fundamental dosimetric characteristics of a novel gated fiber-optic-coupled dosimetry system for clinical electron beam irradiation. Methods: The response of fiber-optic-coupled dosimetry system to clinical electron beam, with nominal energy range of 6-20 MeV, was evaluated for reproducibility, linearity, and output dependence on dose rate, dose per pulse, energy, and field size. The validity of the detector system's response was assessed in correspondence with a reference ionization chamber. Results: The fiber-optic-coupled dosimetry system showed little dependence to dose rate variations (coefficient of variation {+-}0.37%) and dose per pulse changes (with 0.54% of reference chamber measurements). The reproducibilitymore » of the system was {+-}0.55% for dose fractions of {approx}100 cGy. Energy dependence was within {+-}1.67% relative to the reference ionization chamber for the 6-20 MeV nominal electron beam energy range. The system exhibited excellent linear response (R{sup 2}=1.000) compared to reference ionization chamber in the dose range of 1-1000 cGy. The output factors were within {+-}0.54% of the corresponding reference ionization chamber measurements. Conclusions: The dosimetric properties of the gated fiber-optic-coupled dosimetry system compare favorably to the corresponding reference ionization chamber measurements and show considerable potential for applications in clinical electron beam radiotherapy.« less

  11. Long-term bradycardia caused by atrioventricular block can remodel the canine heart to detect the histamine H1 blocker terfenadine-induced torsades de pointes arrhythmias.

    PubMed

    Takahara, Akira; Sugiyama, Atsushi; Ishida, Yuko; Satoh, Yoshioki; Wang, Kai; Nakamura, Yuji; Hashimoto, Keitaro

    2006-03-01

    Although a second-generation histamine H(1) blocker terfenadine induced torsades de pointes (TdP) arrhythmias in patients via the blockade of a rapid component of delayed rectifier K(+) current (I(Kr)), such action of terfenadine has not been detected in previous animal models. We analysed the potential of the canine persistent atrioventricular block heart, a new in vivo proarrhythmia model, to detect a torsadogenic effect of terfenadine of an oral dose of 3 or 30 mg kg(-1). The doses can provide therapeutic to supra-therapeutic plasma concentrations as an anti-histamine. In 2 weeks of bradycardiac heart model, there were no significant changes in any of the electrocardiogram parameters after the administration of both doses of terfenadine. In 4-6 weeks of bradycardiac heart model, the low dose of terfenadine hardly affected any of the electrocardiogram parameters except that it induced TdP in one out of six animals. The high dose significantly decreased the atrial rate and ventricular rate, prolonged the QT interval, and induced TdP in five out of six animals. Moreover, temporal variability of repolarization increased after the high-dose administration. These results suggest that long-term bradycardia caused by atrioventricular block can remodel the canine heart to detect terfenadine-induced TdP.

  12. Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovarik, Libor; Stevens, Andrew J.; Liyu, Andrey V.

    Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce themore » electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. As a result, the use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO 3, a material that is traditionally difficult to image by TEM/STEM because of dose issues.« less

  13. Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

    DOE PAGES

    Kovarik, Libor; Stevens, Andrew J.; Liyu, Andrey V.; ...

    2016-10-17

    Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce themore » electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. The use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO3, a material that is traditionally difficult to image by TEM/STEM because of dose issues.« less

  14. [Research on the expression of Survivin and PTEN in laryngeal squamous cell carcinoma transplanted on the back sides of nude mice treated by gold throat tablets].

    PubMed

    Guo, Qiangzhong; Li, Yunying

    2012-12-01

    To explore the positive expressing rates of oncogene Survivin and tumor-suppressor gene PTEN in transplanted laryngo-carcinoma of nude mice treated by Gold Throat Tablets (GTT) which can improve circulation and remove haemostasis in TCM theory. The 32 nude mice seeded with cultured laryngeal carcinoma cells subcutaneously at the back were randomly divided into high, middle, low (according to 6 : 3: 1 proportion of GTT dosing given by intragastric administration) dose groups and blank control groups. The changes on weight and size of tumors originated from these cells were observed for 28 days, and the density of tumors and expression of Survivin and PTEN were examined with tumor sections by immunohistochemical assay after separating tumors from back of nude mice. The weight and size of subcutaneous laryngo-carcinoma on backs of high dose group nude mice were both the smallest among all the experimental groups with the average density of tumors as 1.202 g/cm3. The positive expressing rates of Survivin and PTEN both revealed the following tendency that high dose group < middle dose group < low dose group < blank control group. Six times of regular doses of GTT can prevent overgrowth of laryngo-carcinoma transplanted on nude mice and decrease the excessive expression of oncogene Survivin in the tumor. PTEN, expressing lower than Survivin in all groups, shows a subordinative relationship with it, maybe due to a competition mechanism.

  15. Comparison in vivo Study of Genotoxic Action of High- Versus Very Low Dose-Rate γ-Irradiation

    PubMed Central

    Osipov, A. N.; Klokov, D. Y.; Elakov, A. L.; Rozanova, O. M.; Zaichkina, S. I.; Aptikaeva, G. F.; Akhmadieva, A. Kh.

    2004-01-01

    The aim of the present study was to compare genotoxicity induced by high- versus very low dose-rate exposure of mice to γ-radiation within a dose range of 5 to 61 cGy using the single-cell gel electrophoresis (comet) assay and the micronucleus test. CBA/lac male mice were irradiated at a dose rate of 28.2 Gy/h (high dose rate) or 0.07 mGy/h (very low dose rate). The comet assay study on spleen lymphocytes showed that very low dose-rate irradiation resulted in a statistically significant increase in nucleoid relaxation (DNA breaks), starting from a dose of 20 cGy. Further prolongation of exposure time and, hence, increase of a total dose did not, however, lead to further increase in the extent of nucleoid relaxation. Doses of 20 and 61 cGy were equal in inducing DNA breaks in mouse spleen lymphocytes as assayed by the comet assay. Of note, the level of DNA damage by 20–61 cGy doses of chronic irradiation (0.07 mGy/h) was similar to that an induced by an acute (28.2 Gy/h) dose of 14 cGy. The bone marrow micronucleus test revealed that an increase in polychromatic erythrocytes with micronuclei over a background level was induced by very low-level γ-irradiation with a dose of 61 cGy only, with the extent of the cytogenetic effect being similar to that of 10 cGy high-dose-rate exposure. In summary, presented results support the hypothesis of the nonlinear threshold nature of mutagenic action of chronic low dose-rate irradiation. PMID:19330145

  16. The estimation of galactic cosmic ray penetration and dose rates

    NASA Technical Reports Server (NTRS)

    Burrell, M. O.; Wright, J. J.

    1972-01-01

    This study is concerned with approximation methods that can be readily applied to estimate the absorbed dose rate from cosmic rays in rads - tissue or rems inside simple geometries of aluminum. The present work is limited to finding the dose rate at the center of spherical shells or behind plane slabs. The dose rate is calculated at tissue-point detectors or for thin layers of tissue. This study considers cosmic-rays dose rates for both free-space and earth-orbiting missions.

  17. A quantitative three-dimensional dose attenuation analysis around Fletcher-Suit-Delclos due to stainless steel tube for high-dose-rate brachytherapy by Monte Carlo calculations.

    PubMed

    Parsai, E Ishmael; Zhang, Zhengdong; Feldmeier, John J

    2009-01-01

    The commercially available brachytherapy treatment-planning systems today, usually neglects the attenuation effect from stainless steel (SS) tube when Fletcher-Suit-Delclos (FSD) is used in treatment of cervical and endometrial cancers. This could lead to potential inaccuracies in computing dwell times and dose distribution. A more accurate analysis quantifying the level of attenuation for high-dose-rate (HDR) iridium 192 radionuclide ((192)Ir) source is presented through Monte Carlo simulation verified by measurement. In this investigation a general Monte Carlo N-Particles (MCNP) transport code was used to construct a typical geometry of FSD through simulation and compare the doses delivered to point A in Manchester System with and without the SS tubing. A quantitative assessment of inaccuracies in delivered dose vs. the computed dose is presented. In addition, this investigation expanded to examine the attenuation-corrected radial and anisotropy dose functions in a form parallel to the updated AAPM Task Group No. 43 Report (AAPM TG-43) formalism. This will delineate quantitatively the inaccuracies in dose distributions in three-dimensional space. The changes in dose deposition and distribution caused by increased attenuation coefficient resulted from presence of SS are quantified using MCNP Monte Carlo simulations in coupled photon/electron transport. The source geometry was that of the Vari Source wire model VS2000. The FSD was that of the Varian medical system. In this model, the bending angles of tandem and colpostats are 15 degrees and 120 degrees , respectively. We assigned 10 dwell positions to the tandem and 4 dwell positions to right and left colpostats or ovoids to represent a typical treatment case. Typical dose delivered to point A was determined according to Manchester dosimetry system. Based on our computations, the reduction of dose to point A was shown to be at least 3%. So this effect presented by SS-FSD systems on patient dose is of concern.

  18. Estimation of ambient dose equivalent distribution in the 18F-FDG administration room using Monte Carlo simulation.

    PubMed

    Nagamine, Shuji; Fujibuchi, Toshioh; Umezu, Yoshiyuki; Himuro, Kazuhiko; Awamoto, Shinichi; Tsutsui, Yuji; Nakamura, Yasuhiko

    2017-03-01

    In this study, we estimated the ambient dose equivalent rate (hereafter "dose rate") in the fluoro-2-deoxy-D-glucose (FDG) administration room in our hospital using Monte Carlo simulations, and examined the appropriate medical-personnel locations and a shielding method to reduce the dose rate during FDG injection using a lead glass shield. The line source was assumed to be the FDG feed tube and the patient a cube source. The dose rate distribution was calculated with a composite source that combines the line and cube sources. The dose rate distribution was also calculated when a lead glass shield was placed in the rear section of the lead-acrylic shield. The dose rate behind the automatic administration device decreased by 87 % with respect to that behind the lead-acrylic shield. Upon positioning a 2.8-cm-thick lead glass shield, the dose rate behind the lead-acrylic shield decreased by 67 %.

  19. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE PAGES

    Hiller, Mauritius; Dewji, Shaheen Azim

    2017-02-16

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  20. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiller, Mauritius; Dewji, Shaheen Azim

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  1. Treatment of menopausal symptoms with three low-dose continuous sequential 17β-estradiol/progesterone parenteral monthly formulations using novel non-polymeric microsphere technology

    PubMed Central

    Cortés-Bonilla, Manuel; Bernardo-Escudero, Roberto; Alonso-Campero, Rosalba; Francisco-Doce, María T.; Hernández-Valencia, Marcelino; Celis-González, Cuauhtémoc; Márquez-Oñate, Ricardo; Chedraui, Peter; Uribe, Juan A.

    2015-01-01

    Abstract Objective: To analyze the short-term efficacy and safety over menopausal symptoms of three low-dose continuous sequential 17β-estradiol (E)/progesterone (P) parental monthly formulations using novel non-polymeric microspheres. Methods: This was a multicenter, randomized, single blinded study in which peri- and postmenopausal women were assigned to receive a monthly intramuscular injection of 0.5 mg E + 15 mg P (Group A, n = 34), 1 mg E + 20 mg P (Group B, n = 24) or 1 mg E + 30 mg P (Group C, n = 26) for 6 months. Primary efficacy endpoints included mean change in the frequency and severity of hot flushes and the effect over urogenital atrophy symptoms at 3 and 6 months. Safety variables included changes in the rate of amenorrhea, endometrial thickness and histopathology, and local and systemic adverse events. Results: Compared to baseline at month 6, the three treatment schemes significantly decreased the rate of urogenital atrophy symptoms and the frequency (mean number per day) and severity (mean number graded as moderate and severe per month) of hot flushes. No differences in studied efficacy parameters were observed between studied groups at baseline or at the end of the study. For all groups the most frequent adverse event was pain at the injection site; however they were all rated as mild. At the end of the study peri- and postmenopausal women displayed no significant changes in endometrial thickness or histopathology in all treated groups. The rate of amenorrhea at the end of the study decreased for all studied groups yet was less evident among postmenopausal women as compared to perimenopausal ones. Conclusions: The three low-dose continuous sequential intramuscular monthly treatments of E/P using novel microsphere technology were effective at reducing menopausal symptoms at short-term with a low rate of adverse events. More long-term and comparative research is warranted to support our positive findings. PMID:26062108

  2. Spectrum determination and modification of the AFRL Co-60 cell

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turinetti, J.R.; Kemp, W.T.; Chavez, J.R.

    The AFRL Co-60 cell at Phillips Research Site, Kirtland Air Force Base, is a 1500 ft{sup 2} concrete room with a 5200 Ci, as of 18 December 1996, J.L. Shepherd Co-60 source. The source provides high dose rate ionizing radiation up to 12000 rad(Si)/min. The Co-60 cell is used to characterize total-dose gamma effects of microelectronic and photonic devices, circuits, and subsystems. The spectrum of a Co-60 facility includes more than the two photopeaks of gamma ray emission. If there is a large low energy contribution from scattering, dose enhancement might be a problem. It is important to know themore » spectrum of a Co-60 facility and understand how experimental modifications can change that spectrum. The AFRL Co-60 cell spectrum is found to be a clean spectrum with small low energy contributions and dominant Co-60 photopeaks. Experimental modifications to reduce dose enhancement such as the use of a Pb/Al box and even better a Pb/Sn/Cu/Al box are found to decrease the low energy contributions. Experimental modifications to reduce dose rate such as using lead attenuators in front of the experiment and/or raising the source partially are found to significantly alter the spectrum, sometimes creating large low energy contributions.« less

  3. Dose-Dependent Effect of Statin Pretreatment on Preventing the Periprocedural Complications of Carotid Artery Stenting.

    PubMed

    Hong, Jeong-Ho; Sohn, Sung-Il; Kwak, Jaehyuk; Yoo, Joonsang; Chang, Hyuk Won; Kwon, O-Ki; Jung, Cheolkyu; Chung, Inyoung; Bae, Hee-Joon; Lee, Ji Sung; Han, Moon-Ku

    2017-07-01

    We investigated whether statin pretreatment can dose dependently reduce periprocedural complications in patients undergoing carotid artery stenting because of symptomatic carotid artery stenosis. We enrolled a consecutive series of 397 symptomatic carotid artery stenosis (≥50% stenosis on conventional angiography) treated with carotid artery stenting at 2 tertiary university hospitals over a decade. Definition of periprocedural complications included any stroke, myocardial infarction, and death within 1 month after or during the procedure. Statin pretreatment was divided into 3 categories according to the atorvastatin equivalent dose: none (n=158; 39.8%), standard dose (<40 mg of atorvastatin, n=155; 39.0%), and high dose (≥40 mg; n=84; 21.2%). A multivariable logistic regression analysis with the generalized estimating equation method was used to investigate independent factors in periprocedural complications. The patients' mean age was 68.7 years (81.6% men). The periprocedural complication rates across the 3 categories of statin use were 12.0%, 4.5%, and 1.2%. After adjustment, a change in the atorvastatin dose category was associated with reduction in the odds of periprocedural complications for each change in dose category (standard-dose statin: odds ratio, 0.24; 95% confidence interval, 0.07-0.81; high-dose statin: odds ratio, 0.11; 95% confidence interval, 0.01-0.96; P for trend=0.01). Administration of antiplatelet drugs was also an independent factor in periprocedural complications (OR, 0.18; 95% CI, 0.05-0.69). This study shows that statin pretreatment may reduce the incidence of periprocedural complications dose dependently in patients with symptomatic carotid artery stenting. © 2017 American Heart Association, Inc.

  4. Singlet oxygen explicit dosimetry to predict long-term local tumor control for Photofrin-mediated photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Penjweini, Rozhin; Kim, Michele M.; Ong, Yi Hong; Zhu, Timothy C.

    2017-02-01

    Although photodynamic therapy (PDT) is an established modality for the treatment of cancer, current dosimetric quantities do not account for the variations in PDT oxygen consumption for different fluence rates (φ). In this study we examine the efficacy of reacted singlet oxygen concentration ([1O2]rx) to predict long-term local control rate (LCR) for Photofrin-mediated PDT. Radiation-induced fibrosarcoma (RIF) tumors in the right shoulders of female C3H mice are treated with different in-air fluences of 225-540 J/cm2 and in-air fluence rate (φair) of 50 and 75 mW/cm2 at 5 mg/kg Photofrin and a drug-light interval of 24 hours using a 1 cm diameter collimated laser beam at 630 nm wavelength. [1O2]rx is calculated by using a macroscopic model based on explicit dosimetry of Photofrin concentration, tissue optical properties, tissue oxygenation and blood flow changes during PDT. The tumor volume of each mouse is tracked for 90 days after PDT and Kaplan-Meier analyses for LCR are performed based on a tumor volume <=100 mm3, for the four dose metrics light fluence, photosensitizer photobleaching rate, PDT dose and [1O2]rx. PDT dose is defined as a temporal integral of photosensitizer concentration and Φ at a 3 mm tumor depth. φ is calculated throughout the treatment volume based on Monte-Carlo simulation and measured tissue optical properties. Our preliminary studies show that [1O2]rx is the best dosimetric quantity that can predict tumor response and correlate with LCR. Moreover, [1O2]rx calculated using the blood flow changes was in agreement with [1O2]rx calculated based on the actual tissue oxygenation.

  5. Effects of Intravenous Patient-Controlled Sufentanil Analgesia and Music Therapy on Pain and Hemodynamics After Surgery for Lung Cancer: A Randomized Parallel Study.

    PubMed

    Wang, Yichun; Tang, Haoke; Guo, Qulian; Liu, Jingshi; Liu, Xiaohong; Luo, Junming; Yang, Wenqian

    2015-11-01

    Postoperative pain is caused by surgical injury and trauma; is stressful to patients; and includes a series of physiologic, psychological, and behavioral reactions. Effective postoperative analgesia helps improve postoperative pain, perioperative safety, and hospital discharge rates. This study aimed to observe the influence of postoperative intravenous sufentanil patient-controlled analgesia combined with music therapy versus sufentanil alone on hemodynamics and analgesia in patients with lung cancer. This was a randomized parallel study performed in 60 patients in American Society of Anesthesiologists class I or II undergoing lung cancer resection at the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University. Patients were randomly assigned to a music therapy (MT) group and a control (C) group. The MT group underwent preoperative and postoperative music intervention while the C group did not. Both groups received intravenous patient-controlled sufentanil analgesia. The primary outcome was the visual analogue scale (VAS) score at 24 hours after surgery. The secondary outcomes included hemodynamic changes (systolic blood pressure, diastolic blood pressure, heart rate), changes on the Self-Rating Anxiety Scale (SAS), total consumption of sufentanil, number of uses, sedation, and adverse effects. The postoperative sufentanil dose and analgesia frequency were recorded. Compared with the C group, the MT group had significantly lower VAS score, systolic and diastolic blood pressure, heart rate, and SAS score within 24 hours after surgery (p < 0.01). In addition, postoperative analgesia frequency and sufentanil dose were reduced in the MT group (p < 0.01). Combined music therapy and sufentanil improves intravenous patient-controlled analgesia effects compared with sufentanil alone after lung cancer surgery. Lower doses of sufentanil could be administered to more effectively improve patients' cardiovascular parameters.

  6. Intermittent subcutaneous methadone administration in the management of cancer pain.

    PubMed

    Centeno, Carlos; Vara, Francisco

    2005-01-01

    Methadone is a strong opioid analgesic that has been used successfully in cancer pain management. The oral route of administration is generally preferred for opioid analgesics. However that route sometimes cannot be used. Experience with continuous subcutaneous methadone infusions has produced local intolerance. The aim of this study was to analyze the use of intermittent subcutaneous methadone injections. Ten patients whose pain was well-controlled with oral methadone (average dose 30 mg, range 10 to 120 mg) participated in the study. A subcutaneous small vein needle (butterfly) was used exclusively for administration of methadone. Over a period of seven days the local discomfort of each injection was evaluated by means of a Verbal Numerical Rating Scale (NRS) and the site of infusion was observed. When any degree of erythema or inflammation was seen, the infusion site was changed. The initial subcutaneous dose was the same as the previously administered oral dose. A daily record was kept of the dose used, level of pain, and toxicity symptoms. This close vigilance was aimed at avoiding dosage errors due to variations among individuals in acceptance to previous oral medication. Changes in dosage were allowed according to standard medical criteria. Two patients were withdrawn from the study due to non-painful irritation at the infusion point. Another eight patients tolerated repeated administration of subcutaneous methadone over seven days. Any local irritation from subcutaneous methadone that occurred was managed satisfactorily by changing the infusion site and limiting doses to 30 mg. In seven of 182 repeat administration, injection site changes were necessitated by local irritation. The NRS for local discomfort was 2/10. The two patients who were intolerant of the subcutaneous injections were receiving injected doses which were significantly higher than the others (42 mg as compared to 25 mg). Dose adjustments needed when changing from the oral to the subcutaneous methadone route were minimal. Subcutaneous intermittent administration of methadone appears to be a useful alternative to oral administration in selected clinical situations when oral administration is not feasible.

  7. Xerostomia, salivary characteristics and gland volumes following intensity-modulated radiotherapy for nasopharyngeal carcinoma: a two-year follow up.

    PubMed

    Sim, Cpc; Soong, Y L; Pang, Epp; Lim, C; Walker, G D; Manton, D J; Reynolds, E C; Wee, Jts

    2018-06-01

    To evaluate changes in xerostomia status, salivary characteristics and gland volumes 2 years following radiotherapy in nasopharyngeal carcinoma patients. Xerostomia scores, salivary flow rates, pH and buffering capacity were measured at pre-radiotherapy, mid-radiotherapy, 2 weeks, 3 months and 2 years post-radiotherapy. Salivary gland volumes and their correlation with radiation dose were also assessed. Mean radiation dose to oral cavity, parotid and submandibular glands (SMG) was 44.5, 65.0 and 38.6 Gy respectively. Parotid and SMG volumes decreased 33% at 3 months post-radiotherapy; volumes at 2 years post-radiotherapy were 84% and 51% of pre-radiotherapy levels, respectively. Correlations were observed between parotid gland volume per cent reduction and its radiation dose and between resting salivary flow rate reduction and post-radiotherapy/pre-radiotherapy SMG volume ratio. Salivary flow rates and resting saliva pH remained significantly low at 2 years post-radiotherapy (both flow rates, P = 0.001; resting saliva pH, P = 0.005). Similarly, xerostomia scores remained significantly higher compared with pre-radiotherapy levels. Submandibular gland volumetric shrinkage persisted 2 years after radiotherapy. Xerostomia scores remained significantly higher, and salivary flow rates and resting saliva pH remained significantly lower, suggesting that study participants were still at risk for hyposalivation-related oral diseases. © 2018 Australian Dental Association.

  8. One-Year Follow-Up of Serum Prolactin Level in Schizophrenia Patients Treated with Blonanserin: A Case Series.

    PubMed

    Takahashi, Sakae; Suzuki, Masahiro; Uchiyama, Makoto

    2015-10-01

    In our previous study, a prolactin elevation was more frequently in risperidone than in blonanserin; however, it was more often in blonanserin than in olanzapine. Therefore, while a rate of PRL rising is low to moderate, hyperprolactinemia is a considerable adverse effect in the blonanserin treatment. In this study, to examine detailed characteristics of hyperprolactinemia of blonanserin, we analyzed the prolactin data in six schizophrenic patients who were switched to blonanserin from other antipsychotics and followed for one year. As a result, blonanserin dose was clearly associated with serum prolactin level. The average prolactin level was almost normal when the mean blonanserin dosage was 8.0 mg/day. Regardless of the dose decrease of blonanserin, there were no remarkable changes in symptoms and social functions. Based on our findings, we conclude that low dose blonanserin medication may be useful for schizophrenia maintenance treatment without hyperprolactinemia and a high rate of relapse.

  9. One-Year Follow-Up of Serum Prolactin Level in Schizophrenia Patients Treated with Blonanserin: A Case Series

    PubMed Central

    Suzuki, Masahiro; Uchiyama, Makoto

    2015-01-01

    In our previous study, a prolactin elevation was more frequently in risperidone than in blonanserin; however, it was more often in blonanserin than in olanzapine. Therefore, while a rate of PRL rising is low to moderate, hyperprolactinemia is a considerable adverse effect in the blonanserin treatment. In this study, to examine detailed characteristics of hyperprolactinemia of blonanserin, we analyzed the prolactin data in six schizophrenic patients who were switched to blonanserin from other antipsychotics and followed for one year. As a result, blonanserin dose was clearly associated with serum prolactin level. The average prolactin level was almost normal when the mean blonanserin dosage was 8.0 mg/day. Regardless of the dose decrease of blonanserin, there were no remarkable changes in symptoms and social functions. Based on our findings, we conclude that low dose blonanserin medication may be useful for schizophrenia maintenance treatment without hyperprolactinemia and a high rate of relapse. PMID:26508971

  10. The big bang of hemofiltration: the beginning of a new era in the third millennium for extra-corporeal blood purification!

    PubMed

    Honore', P M; Joannes-Boyau, O; Merson, L; Boer, W; Piette, V; Galloy, A-C; Janvier, G

    2006-07-01

    Since the last decade, hemofiltration and especially high volume hemofiltration has rapidly evolved from a somewhat experimental treatment towards a potentially effective 'adjunctive' therapy in severe septic shock and especially refractory or catecholamine resistant hypodynamic septic shock. Nevertheless, this approach lacks prospective randomized studies (PRT'S) evaluating the critical role of early hemofiltration in sepsis. An important step forward which could be called the 'big bang' in term of hemofiltration was the publication of a PRT in patients with acute renal failure (ARF) (1). Before this study (2), nobody believed that hemofiltration could change the survival rate in intensive care. Since that big bang, many physicians consider that hemofiltration at a certain dose can change the survival rate in intensive care. So the world of hemofiltration in ICU is not a definitive world, it is still in expansion. Indeed, we now have to try to define what will be the exact dose we need in septic acute renal failure. This dose might well be 'higher' than 35 ml/kg/hour in the septic acute renal failure 'group' as suggested by many studies (2-5). At present, it is the issue of continuous dose of high volume hemofiltration that has to be tested in future randomized studies. Since the Vicenza study (2) has shown that 35 ml/kg/h is the best dose in terms of survival, dealing with non septic acute renal failure in ICU, several studies from different groups have shown that, in septic acute renal failure, a higher dose might correlate with better survival. This has also been shown in some way by the study of the 'Vicenza group' but not with a statistically significant value (2). New PRT'S have just started in Europe like the IVOIRE study (hIgh VOlume in Intensive caRE) (6) and the RENAL study. Another large study is looking more basically at dose in non septic acute renal failure in Australasia and is led by the group of Rinaldo Bellomo in Melbourne (7) as well as the ATN study (8) led by Palevsky and colleagues in the USA, also testing the importance of dose in the treatment for ARF. Nevertheless, 'early goal-directed hemofiltration therapy' like early goal directed therapy (9) has to be studied in our critical ill patients. Regarding this issue, fewer studies, mainly retrospective exist, but again the IVOIRE study (6) will address this issue by studying septic patients with acute renal injury according to the Rifle classification (10). So, this review focuses on the early application and on the adequate dose of continuous high volume hemofiltration in septic shock in order to improve not only hemodynamics, but survival in this very severely ill cohort of patients. This could well be called the 'big bang of hemofiltration' as one could never have anticipated that an adequate dose of hemofiltration could markedly influence the survival rate of ICU-septic acute renal failure patients. On top of the use of early and adequate dose of hemofiltration in sepsis, a higher dose could also provide better renal recovery rate and reduce the risk of associate chronic dialysis in these patients. Furthermore, this paper also reviews 'brand' new theories regarding the rationale for hemofiltration in sepsis. Finally, this paper also addresses the so-called negative studies as well anticipated side effects.

  11. WE-FG-BRA-05: Potential Clinical Benefit of LINAC Flattening-Filter-Free (FFF) Mode - Improvement of Treatment Therapeutic Ratio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, S; Department of Biomedical Engineering, University of North Carolina- Chapel Hill/ North Carolina State University, Chapel Hill, North Carolina; Lineberger Clinical Cancer Center, University of North Carolina, Chapel Hill, NC

    Purpose: Ultrahigh dose-rate radiation at >40Gy/s has demonstrated astonishing normal-tissue sparing and tumor control in recent preclinical naive and tumor-bearing rodent studies when compared to the same radiation dose at a conventional dose-rate. The working mechanism of this fascinating dose-rate effect is currently under investigation. The aims of this work include investigating 1) whether LINAC FFF mode radiation at approximately 1Gy/s also has an improved therapeutic ratio compared to the same radiation dose at the conventional dose-rate of 0.05Gy/s, and 2) the dose-rate effect’s potential working mechanism by studying the expression of the P53 gene, linked to tumor suppression andmore » cell regulation after radiation damage. Methods: We used mouse model C57BL/6J, the same as that used in the ultrahigh dose-rate studies, and exposed them to total body irradiation (TBI) using the Elekta Versa accelerator 10MV photons. Mice (N=20) were given a total dose of 12Gy in both the high dose-rate group (n=10) using the FFF-mode and the conventional dose-rate group (n=10) using the conventional does rate mode. The FFF-mode treatment setup consisted of a 15cm×15cm field size setting at 53.2cm SSD while the conventional-mode set-up consisted of a 10cm×10cm field size at 100SSD. Post-radiation, animals were monitored daily for survival analysis and signs of moribundity requiring euthanasia. In addition, mouse spleens were harvested for P53 analysis at different time points. Results: For 12Gy TBI, the 1.3Gy/s FFF-mode high dose-rate produced a statistically significant (p=0.02) improvement in mouse survival compared to the 0.05Gy/s conventional dose-rate. An initial P53 study at the time of death time-point indicates that high dose-rate radiation induced a stronger expression of P53 than conventional dose-rate radiation. Conclusion: Our pilot study indicates that the FFF-mode high dose-rate radiation, which has been used largely to improve clinical throughput, may provide the added clinical benefit of improving treatment therapeutic ratio. Animal Studies were performed within the LCCC Animal Studies Core Facility at the University of North Carolina at Chapel Hill. The LCCC Animal Studies Core is supported in part by an NCI Center Core Support Grant (CA16086) to the UNC Lineberger Comprehensive Cancer Center.« less

  12. Febrile events including convulsions following the administration of four brands of 2010 and 2011 inactivated seasonal influenza vaccine in NZ infants and children: the importance of routine active safety surveillance.

    PubMed

    Petousis-Harris, Helen; Poole, Tracey; Turner, Nikki; Reynolds, Gary

    2012-07-13

    To evaluate and compare rates of febrile events, including febrile convulsion, following immunisation with four brands of inactivated 2010 and 2011 influenza vaccine in NZ infants and children. Retrospective telephone surveys of parents of infants and children who received at least one dose of the vaccines of interest. 184 NZ General Practices who received the vaccines of interest. Recipients of 4088 doses of trivalent inactivated vaccines Fluvax(®), Vaxigrip(®), Influvac(®) and Fluarix(®) and/or monovalent Celvapan. Vaccinees were identified via the electronic Practice Management System and contacted consecutively. Primary outcome was febrile convulsive seizure. Secondary outcomes were presence of fever plus other organ system specific symptoms. The parental response rate was 99%. Of 4088 doses given, 865 were Fluvax(®), 2571 Vaxigrip(®), 204 Influvac(®), 438 Fluarix(®) and 10 Celvapan. Three febrile convulsions followed Fluvax(®), a rate of 35 per 10,000 doses. No convulsions occurred following any dose of the other vaccines. There were nine febrile events that included rigors, all following Fluvax(®). Fever occurred significantly more frequently following administration of Fluvax(®) compared with the other brands of vaccines (p<0.0001) and Fluvax recipients were more likely to seek medical attention. Influvac(®) also had higher rates of febrile reactions (OR 0.54, 0.36-0.81) than the other two brands Vaxigrip(®) (OR 0.21, 0.16-0.27) and Fluarix(®) (OR 0.10, 0.05-0.20). After multivariable analysis vaccine, European ethnicity and second dose of vaccine were significantly associated with reporting of fever within 24h of vaccination. Influenza vaccines have different rates of reactogenicity in children which varies between ethnic groups. High rates of febrile convulsions and reactions in children receiving Fluvax(®) and to a lesser extent the higher fever rates in those receiving Influvac(®) compared with the other two brands of influenza vaccines in this study suggests that reactogenicity profiles need to be considered prior to national policy advice each season. The risk-benefit profile in children might not be equally favourable for all licensed paediatric influenza vaccines. More attention needs to be given to comparative research for all trivalent seasonal vaccines, and with all strain changes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Early Assessment of Treatment Responses During Radiation Therapy for Lung Cancer Using Quantitative Analysis of Daily Computed Tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paul, Jijo; Yang, Cungeng; Wu, Hui

    Purpose: To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Methods and Materials: Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from themore » daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. Results: During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R{sup 2} > 0.99) and correlates weakly with the change in GTV (R{sup 2} = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Conclusion: Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer.« less

  14. Early Assessment of Treatment Responses During Radiation Therapy for Lung Cancer Using Quantitative Analysis of Daily Computed Tomography.

    PubMed

    Paul, Jijo; Yang, Cungeng; Wu, Hui; Tai, An; Dalah, Entesar; Zheng, Cheng; Johnstone, Candice; Kong, Feng-Ming; Gore, Elizabeth; Li, X Allen

    2017-06-01

    To investigate early tumor and normal tissue responses during the course of radiation therapy (RT) for lung cancer using quantitative analysis of daily computed tomography (CT) scans. Daily diagnostic-quality CT scans acquired using CT-on-rails during CT-guided RT for 20 lung cancer patients were quantitatively analyzed. On each daily CT set, the contours of the gross tumor volume (GTV) and lungs were generated and the radiation dose delivered was reconstructed. The changes in CT image intensity (Hounsfield unit [HU]) features in the GTV and the multiple normal lung tissue shells around the GTV were extracted from the daily CT scans. The associations between the changes in the mean HUs, GTV, accumulated dose during RT delivery, and patient survival rate were analyzed. During the RT course, radiation can induce substantial changes in the HU histogram features on the daily CT scans, with reductions in the GTV mean HUs (dH) observed in the range of 11 to 48 HU (median 30). The dH is statistically related to the accumulated GTV dose (R 2  > 0.99) and correlates weakly with the change in GTV (R 2  = 0.3481). Statistically significant increases in patient survival rates (P=.038) were observed for patients with a higher dH in the GTV. In the normal lung, the 4 regions proximal to the GTV showed statistically significant (P<.001) HU reductions from the first to last fraction. Quantitative analysis of the daily CT scans indicated that the mean HUs in lung tumor and surrounding normal tissue were reduced during RT delivery. This reduction was observed in the early phase of the treatment, is patient specific, and correlated with the delivered dose. A larger HU reduction in the GTV correlated significantly with greater patient survival. The changes in daily CT features, such as the mean HU, can be used for early assessment of the radiation response during RT delivery for lung cancer. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volotskova, O; Xu, A; Jozsef, G

    Purpose: To investigate the response and dose rate dependence of a scintillation detector over a wide energy range. Methods: The energy dependence of W1 scintillation detector was tested with: 1) 50–225 keV beams generated by an animal irradiator, 2) a Leksell Gamma Knife Perfexion Co-60 source, 3) 6MV, 6FFF, 10FFF and 15MV photon beams, and 4) 6–20MeV electron beams from a linac. Calibrated linac beams were used to deliver 100 cGy to the detector at dmax in water under reference conditions. The gamma-knife measurement was performed in solid water (100 cGy with 16mm collimator). The low energy beams were calibratedmore » with an ion chamber in air (TG-61), and the scintillation detector was placed at the same location as the ionization chamber during calibration. For the linac photon and electron beams, dose rate dependence was tested for 100–2400 and 100–800 MU/min. Results: The scintillation detector demonstrated strong energy dependence in the range of 50–225keV. The measured values were lower than the delivered dose and increased as the energy increased. Therapeutic photon beams showed energy independence with variations less than 1%. Therapeutic electron beams displayed the same sensitivity of ∼2–3% at their corresponding dmax depths. The change in dose-rate of photon and electron beams within the therapeutic energy range did not affect detector output (<0.5%). Measurements acquired with the gamma knife showed that the output data agreed with the delivered dose up to 3%. Conclusion: W1 scintillation detector output has a strong energy dependence in the diagnostic and orthovoltage energy range. Therapeutic photon beams exhibited energy independence with no observable dose-rate dependence. This study may aid in the implementation of a scintillation detector in QA programs by providing energy calibration factors.« less

  16. Radiation doses to critical groups since the early 1950s due to discharges of liquid radioactive waste from Sellafield.

    PubMed

    Hunt, G J

    1997-04-01

    First, some of the early work is reviewed on exposure pathways in connection with proposed and early liquid radioactive waste discharges from Sellafield. The main historical features of these discharges, affected by relevant plant operations, are then briefly described. The important radiological exposure pathways resulting from the discharges and people's consumption and occupancy habits are considered. To place the changing scenario onto a consistent basis using present-day methodology, a reconstruction of exposures has been carried out using environmental monitoring data and models. The three major pathways are examined of Porphyra/laverbread consumption in South Wales, fish and shellfish consumption near Sellafield, and external exposure over local and more distant sediments. The results show that over the period 1952 to about 1970 the laverbread pathway was probably critical, taking a cautious approach. Effective dose rates fluctuated at around 1 mSv y(-1) from about 1956 to 1971. From about 1970 to 1985, the fish and shellfish pathway was likely to have been critical, with effective dose rates peaking at about 2 mSv y(-1) in 1975-1976. External exposure was likely to have been of lesser importance than the other two pathways until about 1985, when with the retention of previously-released radiocesium on sediments it has become dominant. This phenomenon applies particularly further afield where radiocesium concentrations have been slower to decline; in the Ribble estuary, houseboat dwellers have been the critical group from about 1985. Effective doses have been at about 0.3 mSv y(-1) and declining; they are due to the effects of radiocesium discharges in earlier years. Dose rates have remained within contemporary ICRP dose limits.

  17. Real-world cardiovascular assessment of mirabegron treatment in patients with overactive bladder and concomitant cardiovascular disease: Results of a Japanese post-marketing study.

    PubMed

    Katoh, Takao; Kuwamoto, Kana; Kato, Daisuke; Kuroishi, Kentarou

    2016-12-01

    To assess the effect of 25 or 50 mg mirabegron on cardiovascular end-points and adverse drug reactions in real-world Japanese patients with overactive bladder and cardiovascular disease. Participants had overactive bladder, a history of/coexisting cardiovascular disease and a 12-lead electrocardiogram carried out ≤7 days before initiating 4 weeks of mirabegron treatment. Patients with "serious cardiovascular disease" (class III or IV on the New York Heart Association functional classification and further confirmed by expert analysis) were excluded. Patient demographics, physical characteristics and cardiovascular history were recorded. After 4 weeks, patients underwent another electrocardiogram. Incidence of cardiovascular adverse drug reactions and change from baseline in electrocardiogram parameters (RR, PR, QRS intervals, Fridericia's corrected QT and heart rate) were assessed. Of 316 patients registered, 236 met criteria and had baseline/post-dose electrocardiograms: 61.9% male; 60.2% aged ≥75 years; 93.6% with coexisting cardiovascular disease, notably, arrhythmia (67.8%) and angina pectoris (19.1%). Starting mirabegron daily doses were 25 mg (19.9%) or 50 mg (80.1%). The incidence of cardiovascular adverse drug reactions was 5.51%. After 4 weeks, the mean heart rate increased by 1.24 b.p.m. (statistically significant, but clinically acceptable as per previous trials). No significant changes were observed in PR, QRS or Fridericia's corrected QT. No significant correlations in the total population or age-/sex-segregated subgroups were observed between baseline Fridericia's corrected QT and change at 4 weeks. No correlation for heart rate versus change from baseline heart rate with treatment was observed. Mirabegron was well tolerated in real-world Japanese patients with overactive bladder and coexisting cardiovascular disease. No unexpected cardiovascular safety concerns were observed. © 2016 The Japanese Urological Association.

  18. Comparative performance analysis for computer aided lung nodule detection and segmentation on ultra-low-dose vs. standard-dose CT

    NASA Astrophysics Data System (ADS)

    Wiemker, Rafael; Rogalla, Patrik; Opfer, Roland; Ekin, Ahmet; Romano, Valentina; Bülow, Thomas

    2006-03-01

    The performance of computer aided lung nodule detection (CAD) and computer aided nodule volumetry is compared between standard-dose (70-100 mAs) and ultra-low-dose CT images (5-10 mAs). A direct quantitative performance comparison was possible, since for each patient both an ultra-low-dose and a standard-dose CT scan were acquired within the same examination session. The data sets were recorded with a multi-slice CT scanner at the Charite university hospital Berlin with 1 mm slice thickness. Our computer aided nodule detection and segmentation algorithms were deployed on both ultra-low-dose and standard-dose CT data without any dose-specific fine-tuning or preprocessing. As a reference standard 292 nodules from 20 patients were visually identified, each nodule both in ultra-low-dose and standard-dose data sets. The CAD performance was analyzed by virtue of multiple FROC curves for different lower thresholds of the nodule diameter. For nodules with a volume-equivalent diameter equal or larger than 4 mm (149 nodules pairs), we observed a detection rate of 88% at a median false positive rate of 2 per patient in standard-dose images, and 86% detection rate in ultra-low-dose images, also at 2 FPs per patient. Including even smaller nodules equal or larger than 2 mm (272 nodules pairs), we observed a detection rate of 86% in standard-dose images, and 84% detection rate in ultra-low-dose images, both at a rate of 5 FPs per patient. Moreover, we observed a correlation of 94% between the volume-equivalent nodule diameter as automatically measured on ultra-low-dose versus on standard-dose images, indicating that ultra-low-dose CT is also feasible for growth-rate assessment in follow-up examinations. The comparable performance of lung nodule CAD in ultra-low-dose and standard-dose images is of particular interest with respect to lung cancer screening of asymptomatic patients.

  19. Radiotherapy-induced Early ECG Changes and Their Comparison with Echocardiography in Patients with Early-stage Breast Cancer.

    PubMed

    Tuohinen, Suvi Sirkku; Keski-Pukkila, Konsta; Skyttä, Tanja; Huhtala, Heini; Virtanen, Vesa; Kellokumpu-Lehtinen, Pirkko-Liisa; Raatikainen, Pekka; Nikus, Kjell

    2018-04-01

    Early electrocardiogram (ECG) changes after breast cancer radiotherapy (RT) have been reported, but their characteristics and associated factors are largely unknown. This study aimed to explore early RT-induced ECG changes and to compare them with echocardiography changes. Sixty eligible patients with chemotherapy-naïve left-sided and 20 with right-sided breast cancer were evaluated with echocardiography, blood samples and ECG before and after RT. RT-induced ECG changes in the anterior leads. T-Wave changes were most frequent. T-Wave decline was associated independently with patient age (β=-0.245, p=0.005), mean heart radiation dose (β=1.252, p=0.001) and global systolic strain rate change (β=7.943, p=0.002). T-Wave inversion was associated independently with mean heart radiation dose (β=0.143, p<0.001), global longitudinal strain change (β=0.053, p=0.017) and posterior calibrated integrated backscatter (β=-0.022, p=0.049). RT-induced ECG changes were prevalent and associated with functional and structural changes in echocardiography. ECG could be used for post-RT cardiac screening. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  20. First-principles X-ray absorption dose calculation for time-dependent mass and optical density.

    PubMed

    Berejnov, Viatcheslav; Rubinstein, Boris; Melo, Lis G A; Hitchcock, Adam P

    2018-05-01

    A dose integral of time-dependent X-ray absorption under conditions of variable photon energy and changing sample mass is derived from first principles starting with the Beer-Lambert (BL) absorption model. For a given photon energy the BL dose integral D(e, t) reduces to the product of an effective time integral T(t) and a dose rate R(e). Two approximations of the time-dependent optical density, i.e. exponential A(t) = c + aexp(-bt) for first-order kinetics and hyperbolic A(t) = c + a/(b + t) for second-order kinetics, were considered for BL dose evaluation. For both models three methods of evaluating the effective time integral are considered: analytical integration, approximation by a function, and calculation of the asymptotic behaviour at large times. Data for poly(methyl methacrylate) and perfluorosulfonic acid polymers measured by scanning transmission soft X-ray microscopy were used to test the BL dose calculation. It was found that a previous method to calculate time-dependent dose underestimates the dose in mass loss situations, depending on the applied exposure time. All these methods here show that the BL dose is proportional to the exposure time D(e, t) ≃ K(e)t.

  1. PTW-diamond detector: dose rate and particle type dependence.

    PubMed

    Fidanzio, A; Azario, L; Miceli, R; Russo, A; Piermattei, A

    2000-11-01

    In this paper the suitability of a PTW natural diamond detector (DD) for relative and reference dosimetry of photon and electron beams, with dose per pulse between 0.068 mGy and 0.472 mGy, was studied and the results were compared with those obtained by a stereotactic silicon detector (SFD). The results show that, in the range of the examined dose per pulse the DD sensitivity changes up to 1.8% while the SFD sensitivity changes up to 4.5%. The fitting parameter, delta, used to correct the dose per pulse dependence of solid state detectors, was delta = 0.993 +/- 0.002 and delta = 1.025 +/- 0.002 for the diamond detector and for the silicon diode, respectively. The delta values were found to be independent of particle type of two conventional beams (a 10 MV x-ray beam and a 21 MeV electron beam). So if delta is determined for a radiotherapy beam, it can be used to correct relative dosimetry for other conventional radiotherapy beams. Moreover the diamond detector shows a calibration factor which is independent of beam quality and particle type, so an empirical dosimetric formalism is proposed here to obtain the reference dosimetry. This formalism is based on a dose-to-water calibration factor and on an empirical coefficient, that takes into account the reading dependence on the dose per pulse.

  2. Efficacy and Safety of a Single-Pill Fixed-Dose Combination of Azilsartan and Amlodipine.

    PubMed

    Motozato, Kota; Miura, Shin-Ichiro; Shiga, Yuhei; Kusumoto, Takaaki; Saku, Keijiro

    2016-12-01

    Guidelines for the management of hypertension recommend the use of drugs with different mechanisms of action in antihypertensive regimens that include single-pill fixed-dose combinations of medications. There is some controversy regarding which single-pill fixed-dose combinations of angiotensin II type 1 receptor blockers (ARBs) and calcium channel blockers (CCBs) are effective at reducing blood pressure (BP). Forty hypertensive patients who were receiving a single-pill fixed-dose combination of valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day were enrolled. They were randomly divided into two treatment groups, a group that changed to a single-pill fixed-dose combination of azilsartan 20 mg/day and amlodipine 5 mg/day (changeover group) and a group that continued to receive valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day (control group), and treated for 16 weeks. There were no significant differences in systolic blood pressure (SBP), diastolic blood pressure (DBP) or pulse rate (PR) at 16 weeks between the control and changeover groups. In addition, there were no significant changes in biochemical parameters throughout the study period in both groups. The ability of a single-pill fixed-dose combination of azilsartan and amlodipine to reduce BP may be comparable to that of a combination of valsartan and amlodipine or irbesartan and amlodipine.

  3. Changes in salivary gland function after radiotherapy of head and neck tumors measured by quantitative pertechnetate scintigraphy: Comparison of intensity-modulated radiotherapy and conventional radiation therapy with and without Amifostine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muenter, Marc W.; Hoffner, Simone; Department of Nuclear Medicine, University of Heidelberg, Heidelberg

    2007-03-01

    Purpose: The aim of this study was to compare changes in salivary gland function after intensity-modulated radiotherapy (IMRT) and conventional radiotherapy (RT), with or without Amifostine, for tumors of the head-and-neck region using quantitative salivary gland scintigraphy (QSGS). Methods and Materials: A total of 75 patients received pre- and post-therapeutic QSGS to quantify the salivary gland function. In all, 251 salivary glands were independently evaluated. Changes in the maximum uptake ({delta}U) and relative excretion rate ({delta}F) both pre- and post-RT were determined to characterize radiation-induced changes in the salivary gland function. In addition, dose-response curves were calculated. Results: In allmore » groups, maximum uptake and relative excretion rate were reduced after RT ({delta}U {<=}0 and {delta}F {<=}0). The reduction was significantly lower for IMRT than for conventional RT. For the parotid glands, the reduction was smaller for the IMRT-low than for the IMRT-high group. For the Amifostine-high and the conventional group the difference was significant only for one parameter ({delta}U, parotid and submandibular glands, p < 0.05). In contrast to this, the difference between the Amifostine-low and the conventional group was always significant or at least showed a clear trend for both changes in U and F. In regard to the endpoint 'reduction of the salivary gland excretion rate of more than 50%,' the dose-response curves yielded D{sub 50}-values of 34.2 {+-} 12.2 Gy for the conventionally treated group and 36.8 {+-} 2.9 Gy for the IMRT group. For the Amifostine group, an increased D{sub 50}-values of 46.3 {+-} 2.3 Gy was obtained. Conclusion: Intensity-modulated RT can significantly reduce the loss of parotid gland function when respecting a certain dose threshold. Conventional RT plus Amifostine prevents reduced salivary gland function only in the patient group treated with <40.6 Gy.« less

  4. Diamond detector in absorbed dose measurements in high‐energy linear accelerator photon and electron beams

    PubMed Central

    Binukumar, John Pichy; Amri, Iqbal Al; Davis, Cheriyathmanjiyil Antony

    2016-01-01

    Diamond detectors (DD) are preferred in small field dosimetry of radiation beams because of small dose profile penumbras, better spatial resolution, and tissue‐equivalent properties. We investigated a commercially available ‘microdiamond’ detector in realizing absorbed dose from first principles. A microdiamond detector, type TM 60019 with tandem electrometer is used to measure absorbed doses in water, nylon, and PMMA phantoms. With sensitive volume 0.004 mm3, radius 1.1 mm, thickness 1×10−3mm, the nominal response is 1 nC/Gy. It is assumed that the diamond detector could collect total electric charge (nC) developed during irradiation at 0 V bias. We found that dose rate effect is less than 0.7% for changing dose rate by 500 MU/min. The reproducibility in obtaining readings with diamond detector is found to be ±0.17% (1 SD) (n=11). The measured absorbed doses for 6 MV and 15 MV photons arrived at using mass energy absorption coefficients and stopping power ratios compared well with Nd, water calibrated ion chamber measured absorbed doses within 3% in water, PMMA, and nylon media. The calibration factor obtained for diamond detector confirmed response variation is due to sensitivity due to difference in manufacturing process. For electron beams, we had to apply ratio of electron densities of water to carbon. Our results qualify diamond dosimeter as a transfer standard, based on long‐term stability and reproducibility. Based on micro‐dimensions, we recommend these detectors for pretreatment dose verifications in small field irradiations like stereotactic treatments with image guidance. PACS number(s): 87.56.Da PMID:27074452

  5. Comparative study of nuclear magnetic resonance and UV-visible spectroscopy dose-response of polymer gel based on N-(Isobutoxymethyl) acrylamide

    NASA Astrophysics Data System (ADS)

    Lotfy, S.; Basfar, A. A.; Moftah, B.; Al-Moussa, A. A.

    2017-12-01

    A comparative study of nuclear magnetic resonance and UV-visible spectroscopy of dose-response for polymer gel dosimeters was performed. Dosimeters were prepared using N-(Isobutoxymethyl) acrylamide (NIBMA) as a new monomer via radiation induced polymerization for use in radiotherapy planning. The prepared dosimeters were irradiated with doses up to 30 Gy at a constant dose rate of 600 MU/min. Using a medical linear accelerator at irradiation energies of 6, 10 and 18 MV photon beam. The nuclear magnetic resonance (NMR), via spin-spin relaxation rate (R2) for water proton surrounding the polymer formulation and UV-Visible spectroscopy, via the optical absorbance measurements of irradiated dosimeters at selected wavelengths of 500 nm, was used to investigate the dose response of NIBMAGAT gel dosimeters. Scavenge of oxygen was done using tetrakis (hydroxymethyl) phosphonium chloride (THPC). The THPC optimum concentration in the dosimeters formulations were 5 and 10 mM for the NMR and optical absorbance measurements respectively. The quantitative investigation of the dosimeters components reveals the selective formulations based on 4% w/w gelatin, 1% w/w NIBMA, 3% w/w BisAAm, 5 or 10 mM THPC and 17% w/w glycerol which significantly increase the dosimeters dose response. The prepared dosimeters were found to be dose rate and photon beam irradiation energy independent. The stability study shows no change in the relaxation rate or in the optical absorbance of the gel dosimeters up to 8 days post-irradiation. The prepared polymer gel dosimeters at the energies of 6, 10 and 18 MV photon beam irradiation in the range of 1-30 Gy have the linearity of the dose response function in the case of R2 is better than in the case of absorbance measurements; correlation coefficient (r2) equals 0.995 and 0.991, respectively. Dose sensitivity, R2 of NIBMAGAT dosimeters (0.0775 s-1 Gy-1). The absorption band intensity increases linearly with a dose sensitivity of 0.016 cm-1 Gy-1. The detection limit of the present dosimeter analyzed by R2 and absorbance measurements is 1 Gy and 2 Gy respectively. The overall uncertainty measurements of dose approve that by using the absorbance measurements the gel is not useful as a dosimeter like as R2 measurements. It could be a new composition of dosimeters successfully utilized for MRI (Magnetic Resonance Imaging) for radiotherapy treatment planning.

  6. Effect of transfusional iron intake on response to chelation therapy in beta-thalassemia major.

    PubMed

    Cohen, Alan R; Glimm, Ekkehard; Porter, John B

    2008-01-15

    The success of chelation therapy in controlling iron overload in patients with thalassemia major is highly variable and may partly depend on the rate of transfusional iron loading. Using data from the 1-year phase III study of deferasirox, including volumes of transfused red blood cells and changes in liver iron concentration (LIC) in 541 patients, the effect of iron loading on achieving neutral or negative iron balance was assessed in patients receiving different doses of deferasirox and the comparator deferoxamine. After dose adjustment, reductions in LIC after 1 year of deferasirox or deferoxamine therapy correlated with transfusional iron intake. At a deferasirox dose of 20 mg/kg per day, neutral or negative iron balance was achieved in 46% and 75% of patients with the highest and lowest transfusional iron intake, respectively; 30 mg/kg per day produced successful control of iron stores in 96% of patients with a low rate of transfusional iron intake. Splenectomized patients had lower transfusional iron intake and greater reductions in iron stores than patients with intact spleens. Transfusional iron intake should be monitored on an ongoing basis in thalassemia major patients, and the rate of transfusional iron loading should be considered when choosing the appropriate dose of an iron-chelating agent. This study is registered at http://clinicaltrials.gov as NCT00061750.

  7. Dose estimates for the solid waste performance assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rittman, P.D.

    1994-08-30

    The Solid Waste Performance Assessment calculations by PNL in 1990 were redone to incorporate changes in methods and parameters since then. The ten scenarios found in their report were reduced to three, the Post-Drilling Resident, the Post-Excavation Resident, and an All Pathways Irrigator. In addition, estimates of population dose to people along the Columbia River are also included. The attached report describes the methods and parameters used in the calculations, and derives dose factors for each scenario. In addition, waste concentrations, ground water concentrations, and river water concentrations needed to reach the performance objectives of 100 mrem/yr and 500 person-rem/yrmore » are computed. Internal dose factors from DOE-0071 were applied when computing internal dose. External dose rate factors came from the GENII Version 1.485 software package. Dose calculations were carried out on a spreadsheet. The calculations are described in detail in the report for 63 nuclides, including 5 not presently in the GENII libraries. The spreadsheet calculations were checked by comparison with GENII, as described in Appendix D.« less

  8. Total dose bias dependency and ELDRS effects in bipolar linear devices

    NASA Technical Reports Server (NTRS)

    Yui, C. C.; McClure, S. S.; Rex, B. G.; Lehman, J. M.; Minto, T. D.; Wiedeman, M.

    2002-01-01

    Total dose tests of several bipolar linear devices show sensitivity to both dose rate and bias during exposure. All devices exhibited Enhanced Low Dose Rate Sensitivity (ELDRS). An accelerated ELDRS test method for three different devices demonstrate results similar to tests at low dose rate. Behavior and critical parameters from these tests are compared and discussed.

  9. The Impact of Dose Rate on the Accuracy of Step-and-Shoot Intensity-modulated Radiation Therapy Quality Assurance Using Varian 2300CD.

    PubMed

    Njeh, Christopher F; Salmon, Howard W; Schiller, Claire

    2017-01-01

    Intensity-modulated radiation therapy (IMRT) delivery using "step-and-shoot" technique on Varian C-Series linear accelerator (linac) is influenced by the communication frequency between the multileaf collimator and linac controllers. Hence, the dose delivery accuracy is affected by the dose rate. Our aim was to quantify the impact of using two dose rates on plan quality assurance (QA). Twenty IMRT patients were selected for this study. The plan QA was measured at two different dose rates. A gamma analysis was performed, and the degree of plan modulation on the QA pass rate was also evaluated in terms of average monitor unit per segment (MU/segment) and the total number of segments. The mean percentage gamma pass rate of 94.9% and 93.5% for 300 MU/min and 600 MU/min dose rate, respectively, was observed. There was a significant ( P = 0.001) decrease in percentage gamma pass rate when the dose rate was increased from 300 MU/min to 600 MU/min. There was a weak, but significant association between the percentage pass rate at both dose rate and total number of segments. The total number of MU was significantly correlated to the total number of segments ( r = 0.59). We found a positive correlation between the percentage pass rate and mean MU/segment, r = 0.52 and r = 0.57 for 300 MU/min and 600 MU/min, respectively. IMRT delivery using step-and-shoot technique on Varian 2300CD is impacted by the dose rate and the total amount of segments.

  10. Outcomes in patients with chronic kidney disease not on dialysis receiving extended dosing regimens of darbepoetin alfa: long-term results of the EXTEND observational cohort study

    PubMed Central

    Galle, Jan-Christoph; Addison, Janet; Suranyi, Michael G.; Claes, Kathleen; Di Giulio, Salvatore; Guerin, Alain; Herlitz, Hans; Kiss, István; Farouk, Mourad; Manamley, Nick; Wirnsberger, Gerhard; Winearls, Christopher

    2016-01-01

    Background Extended dosing of the erythropoiesis-stimulating agent (ESA) darbepoetin alfa (DA) once biweekly or monthly reduces anaemia treatment burden. This observational study assessed outcomes and dosing patterns in patients with chronic kidney disease not on dialysis (CKD-NoD) commencing extended dosing of DA. Methods Adult CKD-NoD patients starting extended dosing of DA in Europe or Australia in June 2006 or later were followed up until December 2012. Outcomes included haemoglobin (Hb) concentration, ESA dosing, mortality rates and receipt of dialysis and renal transplantation. Subgroup analyses were conducted for selected outcomes. Results Of 6035 enrolled subjects, 5723 (94.8%) met analysis criteria; 1795 (29.7%) received dialysis and 238 (3.9%) underwent renal transplantation. Mean (standard deviation) Hb concentration at commencement of extended dosing was 11.0 (1.5) g/dL. Mean [95% confidence interval (CI)] Hb 12 months after commencement of extended dosing (primary outcome) was 11.6 g/dL (11.5, 11.6) overall and was similar across countries, with no differences between subjects previously treated with an ESA versus ESA-naïve subjects, subjects with versus without prior renal transplant or diabetics versus non-diabetics. Weekly ESA dose gradually decreased following commencement of extended DA dosing and was similar across subgroups. The decrease in weekly DA dose was accompanied by an increase in the proportion of patients receiving iron therapy. Hb concentrations declined following changes in ESA labels and treatment guidelines. The mortality rate (95% CI) was 7.06 (6.68, 7.46) deaths per 100 years of follow-up. Subjects alive at study end had stable Hb concentrations in the preceding year, while those who died had lower and declining Hb concentrations in their last year. Conclusions Long-term, extended dosing of DA maintained Hb concentrations in patients already treated with an ESA and corrected and maintained Hb in ESA-naïve patients. PMID:27190334

  11. Enhanced Low Dose Rate Effects in Bipolar Circuits: A New Hardness Assurance Problem for NASA

    NASA Technical Reports Server (NTRS)

    Johnston, A.; Barnes, C.

    1995-01-01

    Many bipolar integrated circuits are much more susceptible to ionizing radiation at low dose rates than they are at high dose rates typically used for radiation parts testing. Since the low dose rate is equivalent to that seen in space, the standard lab test no longer can be considered conservative and has caused the Air Force to issue an alert. Although a reliable radiation hardness assurance test has not yet been designed, possible mechanisms for low dose rate enhancement and hardness assurance tests are discussed.

  12. Overdose and prescribed opioids: Associations among chronic non-cancer pain patients

    PubMed Central

    Dunn, Kate M; Saunders, Kathleen W; Rutter, Carolyn M; Banta-Green, Caleb J; Merrill, Joseph O; Sullivan, Mark D; Weisner, Constance M; Silverberg, Michael J; Campbell, Cynthia I; Psaty, Bruce M; Von Korff, Michael

    2010-01-01

    Background Chronic opioid therapy for chronic non-cancer pain (CNCP) is increasingly common in community practice. Concomitant with this practice change, rates of fatal opioid overdose have increased. It is not known to what extent overdose risks are elevated among patients receiving medically prescribed chronic opioid therapy. Objective To estimate rates of opioid overdose and their association with average prescribed daily opioid dose among patients receiving medically prescribed chronic opioid therapy. Design Cox proportional hazards models were used to estimate overdose risk as a function of average daily opioid dose (morphine equivalents) received at time of overdose. Setting Health maintenance organization. Patients Individuals (n=9940) who received 3+ opioid prescriptions within 90-days for CNCP between 1997 and 2005. Measurements Average daily opioid dose over the previous 90 days from automated pharmacy data. Primary outcomes, non-fatal and fatal overdoses, were identified through diagnostic codes from inpatient and outpatient care and death certificates and confirmed by medical record review. Results Fifty-one opioid-related overdoses were identified, including six deaths. Compared to patients receiving 1-20mg of opioids per day (0.2% annual overdose rate), patients receiving 50-99 mg had a 3.7 fold increase in overdose risk (95% C.I. 1.5, 9.5) and a 0.7% annual overdose rate. Patients receiving 100mg or more per day had an 8.9 fold increase in overdose risk (95% C.I. 4.0, 19.7) and a 1.8% annual overdose rate. Limitations Increased overdose risk among patients on higher dose regimens may be due to confounding by patient differences and by use of opioids in ways not intended by prescribing physicians. The small number of overdoses in the study cohort is also a limitation. Conclusions Patients receiving higher doses of prescribed opioids are at increased risk of opioid overdose, underscoring the need for close supervision of these patients. PMID:20083827

  13. Influence of royal jelly on the reproductive function of puberty male rats.

    PubMed

    Yang, Anshu; Zhou, Ming; Zhang, Li; Xie, Guoxiu; Chen, Hongbing; Liu, Zhiyong; Ma, Wei

    2012-06-01

    The adverse effects of royal jelly on the reproductive system of puberty male rats were investigated. Royal jelly was daily administered by gavage to Sprague-Dawley rats at doses 200, 400, and 800 mg/kg for 4 weeks. The body weight and organ coefficients were determined. Sperm count, spermatozoa abnormality, and testicular histopathology were examined through light microscopy. Radioimmunoassay was used to detect serum hormones. The dietary exposure to royal jelly did not affect body weight, but the organ coefficients for the pituitary and testis in the high-dose group were decreased significantly compared with the control group, and significant changes in the microstructure of the testis were observed. No significant differences in sperm count were observed among all groups, however, the sperm deformity rate in the high-dose group increased significantly. Serum hormones in the high-dose group were significantly different from the control group. After royal jelly was stopped for 14 days, the adverse changes were partially reversed and returned to levels close to those in the control group. In conclusion, high-dose royal jelly oral administration for 4 weeks adversely affected the reproductive system of pubescent male rats, but the unfavorable effects are alleviated to some extent by cessation of administration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. A Critical, Nonlinear Threshold Dictates Bacterial Invasion and Initial Kinetics During Influenza

    NASA Astrophysics Data System (ADS)

    Smith, Amber M.; Smith, Amanda P.

    2016-12-01

    Secondary bacterial infections increase morbidity and mortality of influenza A virus (IAV) infections. Bacteria are able to invade due to virus-induced depletion of alveolar macrophages (AMs), but this is not the only contributing factor. By analyzing a kinetic model, we uncovered a nonlinear initial dose threshold that is dependent on the amount of virus-induced AM depletion. The threshold separates the growth and clearance phenotypes such that bacteria decline for dose-AM depletion combinations below the threshold, stay constant near the threshold, and increase above the threshold. In addition, the distance from the threshold correlates to the growth rate. Because AM depletion changes throughout an IAV infection, the dose requirement for bacterial invasion also changes accordingly. Using the threshold, we found that the dose requirement drops dramatically during the first 7d of IAV infection. We then validated these analytical predictions by infecting mice with doses below or above the predicted threshold over the course of IAV infection. These results identify the nonlinear way in which two independent factors work together to support successful post-influenza bacterial invasion. They provide insight into coinfection timing, the heterogeneity in outcome, the probability of acquiring a coinfection, and the use of new therapeutic strategies to combat viral-bacterial coinfections.

  15. A Critical, Nonlinear Threshold Dictates Bacterial Invasion and Initial Kinetics During Influenza.

    PubMed

    Smith, Amber M; Smith, Amanda P

    2016-12-15

    Secondary bacterial infections increase morbidity and mortality of influenza A virus (IAV) infections. Bacteria are able to invade due to virus-induced depletion of alveolar macrophages (AMs), but this is not the only contributing factor. By analyzing a kinetic model, we uncovered a nonlinear initial dose threshold that is dependent on the amount of virus-induced AM depletion. The threshold separates the growth and clearance phenotypes such that bacteria decline for dose-AM depletion combinations below the threshold, stay constant near the threshold, and increase above the threshold. In addition, the distance from the threshold correlates to the growth rate. Because AM depletion changes throughout an IAV infection, the dose requirement for bacterial invasion also changes accordingly. Using the threshold, we found that the dose requirement drops dramatically during the first 7d of IAV infection. We then validated these analytical predictions by infecting mice with doses below or above the predicted threshold over the course of IAV infection. These results identify the nonlinear way in which two independent factors work together to support successful post-influenza bacterial invasion. They provide insight into coinfection timing, the heterogeneity in outcome, the probability of acquiring a coinfection, and the use of new therapeutic strategies to combat viral-bacterial coinfections.

  16. Tumorigenic target cell regions in bone marrow studied by localized dosimetry of 239Pu, 241Am and 233U in the mouse femur.

    PubMed

    Lord, B I; Austin, A L; Ellender, M; Haines, J W; Harrison, J D

    2001-06-01

    To study the temporal change in microdistribution of plutonium-239, americium-241 and uranium-233 in the mouse distal femur and to compare and combine calculated radiation doses with those obtained previously for the femoral shaft. Also, to relate doses to relative risks of osteosarcoma and acute myeloid leukaemia. Computer-based image analysis of neutron-induced and alpha-track autoradiographs of sections of mouse femora was used to quantify the microdistribution of (239)Pu, (241)Am and (233)U from 1 to 448 days after intraperitoneal injection. Localized dose-rates and cumulative doses over this period were calculated for different regions of the marrow spaces in trabecular bone. The results were then combined with previous data for doses to the cortical marrow of the femoral shaft. A morphometric analysis of the distal femur was carried out. Initial deposition on endosteal surfaces and dose-rates near to the trabecular surfaces at 1 day were two to four times greater than corresponding results for cortical bone. Burial was most rapid for (233)U, about twice the rate in cortical bone. As in cortical bone, subsequent uptake into the marrow was seen for (239)Pu and (241)Am but not (233)U. Cumulative doses to 448 days for different regions of trabecular marrow were greater than corresponding values for cortical marrow for each radionuclide. Combined doses reflected the greater overall volume of cortical marrow. Cumulative radiation doses to the 10 microm thick band of marrow adjacent to all endosteal surfaces were in the ratio of approximately 7:3:1 for (239)Pu:(241)Am:(233)U. This ratio is not inconsistent with observed incidences of osteosarcoma induction by the three nuclides. Analysis of doses to different depths of marrow, however, showed that although ratios were probably not significantly different to that for a 10 microm depth, better correlations with osteosarcomagenic risk were obtained with 20-40 microm depths. For acute myeloid leukaemia, the closest relationship between relative risk and doses was obtained by considering only the central 5-10% of marrow, which gave a dose ratio of approximately 12:11:1 for (239)Pu:(241)Am:(233)U respectively.

  17. Carbon Heavy-ion Radiation Induced Biological effects on Oryza sativa L.

    NASA Astrophysics Data System (ADS)

    Zhang, Meng; Sun, Yeqing; Li, Xishan; Gong, Ning; Meng, Qingmei; Liu, Jiawei; Wang, Ting

    2016-07-01

    Large number of researches on rice after spaceflights indicated that rice was a favorable model organism to study biological effects induced by space radiation. The stimulative effect could often be found on rice seedlings after irradiation by low-dose energetic heavy-ion radiation. Spaceflight also could induce stimulative effect on kinds of seeds. To further understand the mechanism of low-dose radiation biological effects and the dose range, the germinated rice seeds which were irradiated by different doses of carbon heavy-ion (0, 0.02, 0.1, 0.2, 1, 2, 5, 10, 15 and 20Gy, LET=27.3keV/µm) were used as materials to study. By investigating the variation of rice phenotype under different doses, we found that 2Gy radiation dose was a dividing point of the phenotypic variation. Transmission electron microscopy was used to observe the variation of mitochondria, chloroplast, endoplasmic reticulum, ribosome and nucleus in mesophyll cell of rice apical meristem at 24 hours after radiation with different doses. The cells were not apparently physiologically damaged when the dose of radiation was less than 2Gy. The number of chloroplast did not change significantly, but the number of mitochondria was significantly increased, and gathered around in the chloroplast and endoplasmic reticulum; the obvious lesion of chloroplast and mitochondria were found at the mesophyll cells when radiation dose was higher than 2Gy. The mitochondria were swelling and appearing blurred crest. The chloroplast and mitochondrial mutation rate increased significantly (p<0.01). These phenomena showed that cell biological changes may be the reasons of the stimulation and inhibition effects with the boundary of 2Gy. Since mitochondrial was an important organelle involved in the antioxidative systems, its dysfunction could result in the increase of reactive oxygen species and lipid peroxidation. We found that the growth stimulation induced by low-dose radiation mainly occurred at three-leaf stage along with the increasing activity of antioxidase system and damages of lipid peroxidation. We also found that the relative expression of genes sdhb and aox1a which encode the key proteins in mitochondria changed differently after exposed to different doses of radiation, and the lower dose of the radiation could cause longer effect. The chlorophyll was an important organ of photosynthesis, its dysfunction could result in the phenotypic variation. We found that the chlorophyll fluorescence parameter Fv/Fm, the content of chlorophyll (including chlorophyll a, chlorophyll b and total chlorophyll) and both the relative expression of CP24 and its encoding gene lhcb6 changed significantly in different doses. The changes of the relative expression of CP24 and its encoding gene lhcb6 were completely opposite at the lower dose and agreed at the higher dose. The possible mechanisms of growth stimulation and inhibition effects induced by low and high dose radiations were discussed on multiple levels. Moreover, our findings were important to understand the spaceflight induced growth stimulation and inhibition effects of plant. Keywords: Heavy-ion radiation; Low dose; Stimulation effect; Inhibition effect; Rice.

  18. Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators.

    PubMed

    Eichmann, Marion; Flühs, Dirk; Spaan, Bernhard

    2009-10-01

    The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. In order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for a refined clinical treatment planning system. The improved dose rate measurements will facilitate a clinical study, which could correlate the therapeutic outcome of a brachytherapy treatment with an applicator and its individual dose rate distribution.

  19. Development of a high precision dosimetry system for the measurement of surface dose rate distribution for eye applicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eichmann, Marion; Fluehs, Dirk; Spaan, Bernhard

    2009-10-15

    Purpose: The therapeutic outcome of the therapy with ophthalmic applicators is highly dependent on the application of a sufficient dose to the tumor, whereas the dose applied to the surrounding tissue needs to be minimized. The goal for the newly developed apparatus described in this work is the determination of the individual applicator surface dose rate distribution with a high spatial resolution and a high precision in dose rate with respect to time and budget constraints especially important for clinical procedures. Inhomogeneities of the dose rate distribution can be detected and taken into consideration for the treatment planning. Methods: Inmore » order to achieve this, a dose rate profile as well as a surface profile of the applicator are measured and correlated with each other. An instrumental setup has been developed consisting of a plastic scintillator detector system and a newly designed apparatus for guiding the detector across the applicator surface at a constant small distance. It performs an angular movement of detector and applicator with high precision. Results: The measurements of surface dose rate distributions discussed in this work demonstrate the successful operation of the measuring setup. Measuring the surface dose rate distribution with a small distance between applicator and detector and with a high density of measuring points results in a complete and gapless coverage of the applicator surface, being capable of distinguishing small sized spots with high activities. The dosimetrical accuracy of the measurements and its analysis is sufficient (uncertainty in the dose rate in terms of absorbed dose to water is <7%), especially when taking the surgical techniques in positioning of the applicator on the eyeball into account. Conclusions: The method developed so far allows a fully automated quality assurance of eye applicators even under clinical conditions. These measurements provide the basis for future calculation of a full 3D dose rate distribution, which then can be used as input for a refined clinical treatment planning system. The improved dose rate measurements will facilitate a clinical study, which could correlate the therapeutic outcome of a brachytherapy treatment with an applicator and its individual dose rate distribution.« less

  20. Nuclear magnetic resonance spectroscopy reveals metabolic changes in living cardiomyocytes after low doses of ionizing radiation.

    PubMed

    Gramatyka, Michalina; Skorupa, Agnieszka; Sokół, Maria

    2018-01-01

    Several lines of evidence indicate that exposure of heart to ionizing radiation increases the risk of cardiotoxicity manifested by heart dysfunction and cardiovascular diseases. It was initially believed that the heart is an organ relatively resistant to radiation. Currently, however, it is suspected that even low doses of radiation (< 2 Gy) may have a negative impact on the cardiovascular system. Cardiotoxicity of ionizing radiation is associated with metabolic changes observed in cardiac cells injured by radiation. In this study, we used human cardiomyocytes as a model system, and studied their metabolic response to radiation using high-resolution magic angle spinning nuclear magnetic resonance techniques (HR-MAS NMR). Human cardiomyocytes cultured in vitro were exposed to ionizing radiation and their survival was assessed by clonogenic assay. Changes in apoptosis intensity and cell cycle distribution after the irradiation were measured as well. NMR spectra of cardiomyocytes were acquired using Bruker Avance 400 MHz spectrometer at a spinning rate of 3200 Hz. Survival of cardiomyocytes after NMR experiments was assessed by the Trypan blue exclusion assay. Exposure of cardiomyocytes to small doses of ionizing radiation had no effect on cell proliferation potential and intensity of cell death. However, analysis of metabolic profiles revealed changes in lipids, threonine, glycine, glycerophosphocholine, choline, valine, isoleucine, glutamate, reduced glutathione and taurine metabolism. The results of this study showed that ionizing radiation affects metabolic profiles of cardiomyocytes even at low doses, which potentially have no effect on cell viability.

  1. Medulloblastoma. The identification of prognostic subgroups and implications for multimodality management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kopelson, G.; Linggood, R.M.; Kleinman, G.M.

    1983-01-15

    For 43 medulloblatoma patients who had five-and ten-year actuarial survival rates of 56%, prognostic factors of statistical significance included: T-stage, M-stage and histopathologic tumor score. Posterior fossa local control rates were also function of T-stage and TS. Combining TS with T-stage, patients fell into three prognostic and local control groups, which may have different future management implications: Small (T1,2) tumors of favorable (TS less than or equal to 5) histology had a 92% ten-year actuarial survival rate with 100% (8/8) local control; no change from current management is suggested. For the intermediate prognosis group, increasing the irradiation dose alone maymore » improve survival because these tumors exhibited an irradiation dose-response relationship. However, it is the poor prognosis group which might be suitable for future adjuvant chemotherapy or radiosensitizer trials since there is no evidence that higher irradiation doses improve local control. This article identifies prognostic subgroups based on histologic type and TM staging in medulloblastoma patients which potentially may be utilized to improve therapeutic results, and confirms the value of staging patients with central nervous system malignancies.« less

  2. Transmutation and activation of reduced activation ferritic martensitic steel in molten salt cooled fusion power plants

    NASA Astrophysics Data System (ADS)

    Cheng, E. T.

    2004-08-01

    Neutron activation analysis was conducted for the reduced activation ferritic/martensitic (RAFM) steel used in flibe molten-salt cooled fusion blankets. After 22.4 MW yr/m 2 of neutron exposure, the RAFM steel first wall in a molten salt blanket with 40% lithium-6 enrichment in lithium was found to be within 1 mSv/h in contact dose rate after 100 yr of cooling. The contact dose rate drops to 30 and 20 μSv/h or less, respectively, when the cooling times are 300 and 500 yr after discharge. The RAFM steel discharged from the high-temperature shield component would be allowed for hands-on recycling after 100 yr of cooling, when the contact dose rate is 10 μSv/h or less. The most significant changes found in the RAFM steel first wall due to nuclear transmutation, are 10% decrease in W and 10% increase in Ti. Additionally, there are minor elements produced: Mn - <1.2%, V - <0.26%, Re - <0.2%, Ta - <0.08%, and Os - <0.1%, all in weight percent. The gaseous elements generated are H and He, and the, respectively, accumulated quantities are about 260 and 190 wppm.

  3. In vitro biotransformation rates in fish liver S9: effect of dosing techniques.

    PubMed

    Lee, Yung-Shan; Lee, Danny H Y; Delafoulhouze, Maximilien; Otton, S Victoria; Moore, Margo M; Kennedy, Chris J; Gobas, Frank A P C

    2014-08-01

    In vitro biotransformation assays are currently being explored to improve estimates of bioconcentration factors of potentially bioaccumulative organic chemicals in fish. The present study compares thin-film and solvent-delivery dosing techniques as well as single versus multiple chemical dosing for measuring biotransformation rates of selected polycyclic aromatic hydrocarbons in rainbow trout (Oncorhynchus mykiss) liver S9. The findings show that biotransformation rates of very hydrophobic substances can be accurately measured in thin-film sorbent-dosing assays from concentration-time profiles in the incubation medium but not from those in the sorbent phase because of low chemical film-to-incubation-medium mass-transfer rates at the incubation temperature of 13.5 °C required for trout liver assays. Biotransformation rates determined by thin-film dosing were greater than those determined by solvent-delivery dosing for chrysene (octanol-water partition coefficient [KOW ] =10(5.60) ) and benzo[a]pyrene (KOW  =10(6.04) ), whereas there were no statistical differences in pyrene (KOW  =10(5.18) ) biotransformation rates between the 2 methods. In sorbent delivery-based assays, simultaneous multiple-chemical dosing produced biotransformation rates that were not statistically different from those measured in single-chemical dosing experiments for pyrene and benzo[a]pyrene but not for chrysene. In solvent-delivery experiments, multiple-chemical dosing produced biotransformation rates that were much smaller than those in single-chemical dosing experiments for all test chemicals. While thin-film sorbent-phase and solvent delivery-based dosing methods are both suitable methods for measuring biotransformation rates of substances of intermediate hydrophobicity, thin-film sorbent-phase dosing may be more suitable for superhydrophobic chemicals. © 2014 SETAC.

  4. SU-E-J-160: 4D Dynamic Arc of Non-Modulated Variable-Dose-Rate Fields for Lung SBRT: A Feasibility Study.

    PubMed

    Yi, B; Yang, X; Niu, Y; Yu, C

    2012-06-01

    Conformal SBRT plans for Lung cancer with static gantry angles are ideal candidates for applying motion tracking because of: (1) better dosimetric conformity with reduced target margin and (2) easier and more faithful target tracking without intensity modulation. This work is to demonstrate that by delivering the target tracking during gantry rotation, we can significantly improve delivery efficiency without negatively affecting plan quality. A lung SBRT plan with static beams was created using CT images of the reference breathing phase. It is converted to an arc plan with variable dose rate followed by the conversion to a 4D plan with the segment aperture morphing (SAM) method (Gui 2010) with considerations of both target location and shape changes as depicted by the 4D CT. Gantry angle ranges were determined from the clinical monitor units, with the 22.2 MU/degree, which is chosen to maximize the dose rate. All segments of the dynamic 4D plan were merged into a single arc with variable dose rate. Each segment occupying 1/10 of the breathing period delivers 6.6 MUs at a dose rate of 1000 MU/min. Delivery time was measured and compared to the planned. The dose distributions of the single phase 3D plan and the arc 4D plan showed little difference. The delivered time for the 4D arc plan agreed with the calculated time, and is almost the same as delivering the 3D plan without target tracking. A 12 Gy treatment takes less than 2.5 min. The feasibility of a novel 4D delivery method where a 3D SBRT plan is converted into 4D arc delivery has been demonstrated. In addition to realizing the conventional target tracking benefits, our method further improves delivery efficiency, which is important for maintaining the geometric relationship between the target motion and the breathing surrogate during treatment. This study is supported by NIH_Grant_1R01CA133539-01 A2. © 2012 American Association of Physicists in Medicine.

  5. SU-E-T-472: A Multi-Dimensional Measurements Comparison to Analyze a 3D Patient Specific QA Tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashmeg, S; Jackson, J; Zhang, Y

    Purpose: To quantitatively evaluate a 3D patient specific QA tool using 2D film and 3D Presage dosimetry. Methods: A brain IMRT case was delivered to Delta4, EBT2 film and Presage plastic dosimeter. The film was inserted in the solid water slabs at 7.5cm depth for measurement. The Presage dosimeter was inserted into a head phantom for 3D dose measurement. Delta4's Anatomy software was used to calculate the corresponding dose to the film in solid water slabs and to Presage in the head phantom. The results from Anatomy were compared to both calculated results from Eclipse and measured dose from filmmore » and Presage to evaluate its accuracy. Using RIT software, we compared the “Anatomy” dose to the EBT2 film measurement and the film measurement to ECLIPSE calculation. For 3D analysis, DICOM file of “Anatomy” was extracted and imported to CERR software, which was used to compare the Presage dose to both “Anatomy” calculation and ECLIPSE calculation. Gamma criteria of 3% - 3mm and 5% - 5mm was used for comparison. Results: Gamma passing rates of film vs “Anatomy”, “Anatomy” vs ECLIPSE and film vs ECLIPSE were 82.8%, 70.9% and 87.6% respectively when 3% - 3mm criteria is used. When the criteria is changed to 5% - 5mm, the passing rates became 87.8%, 76.3% and 90.8% respectively. For 3D analysis, Anatomy vs ECLIPSE showed gamma passing rate of 86.4% and 93.3% for 3% - 3mm and 5% - 5mm respectively. The rate is 77.0% for Presage vs ECLIPSE analysis. The Anatomy vs ECLIPSE were absolute dose comparison. However, film and Presage analysis were relative comparison Conclusion: The results show higher passing rate in 3D than 2D in “Anatomy” software. This could be due to the higher degrees of freedom in 3D than in 2D for gamma analysis.« less

  6. An open treatment trial of duloxetine in elderly patients with dysthymic disorder

    PubMed Central

    Kerner, Nancy; D’Antonio, Kristina; Pelton, Gregory H; Salcedo, Elianny; Ferrar, Jennifer; Roose, Steven P

    2014-01-01

    Objective: We evaluated the efficacy and side effects of the selective serotonin and norepinephrine reuptake inhibitor antidepressant duloxetine in older adults with dysthymic disorder. Methods: Patients ≥ 60 years old with dysthymic disorder received flexible dose duloxetine 20–120 mg daily in an open-label 12-week trial. The main outcomes were change from baseline to 12 weeks in 24-item Hamilton Depression Rating Scale scores and Treatment Emergent Symptoms Scale scores. Response required ≥ 50% decline in Hamilton Depression Rating Scale scores with a Clinical Global Impression of much improved or better, and remission required final Hamilton Depression Rating Scale ≤ 6. Intent-to-treat analyses were conducted with the last observation carried forward. Results: In 30 patients, the mean age was 70.7 (standard deviation (SD) = 7.6) years and 56.7% were female. In intent-to-treat analyses, there were 16 responders (53.3%) and 10 remitters (33.3%). Of these, 19 patients completed the trial. The mean maximum dose was 76.3 mg (SD = 38.5) in the total sample and 101 mg (SD = 17.9) in completers. In the total sample, the mean final dose was 51 mg (SD = 27.2) and correlated significantly with decline in Hamilton Depression Rating Scale (p < .03); decline in Hamilton Depression Rating Scale correlated significantly with decline in Treatment Emergent Symptoms Scale (p < .001). Daily doses above 60 mg were associated with greater improvement and well tolerated. This result was partly confounded by early dropouts having received low doses. Demographic and medical comorbidities, including cardiac disease and hypertension, were not related to response. Somatic side effects were common prior to duloxetine treatment and improved rather than worsened with duloxetine. There were no serious adverse events. Conclusion: Duloxetine at relatively high doses showed moderate efficacy in elderly patients with dysthymic disorder and was well tolerated in successful completers. Reduced somatic symptoms were associated with improvement in depressive symptoms. A systematic placebo-controlled trial of duloxetine in older patients with dysthymic disorder may be warranted. PMID:25177490

  7. Agreement between gamma passing rates using computed tomography in radiotherapy and secondary cancer risk prediction from more advanced dose calculated models

    PubMed Central

    Balosso, Jacques

    2017-01-01

    Background During the past decades, in radiotherapy, the dose distributions were calculated using density correction methods with pencil beam as type ‘a’ algorithm. The objectives of this study are to assess and evaluate the impact of dose distribution shift on the predicted secondary cancer risk (SCR), using modern advanced dose calculation algorithms, point kernel, as type ‘b’, which consider change in lateral electrons transport. Methods Clinical examples of pediatric cranio-spinal irradiation patients were evaluated. For each case, two radiotherapy treatment plans with were generated using the same prescribed dose to the target resulting in different number of monitor units (MUs) per field. The dose distributions were calculated, respectively, using both algorithms types. A gamma index (γ) analysis was used to compare dose distribution in the lung. The organ equivalent dose (OED) has been calculated with three different models, the linear, the linear-exponential and the plateau dose response curves. The excess absolute risk ratio (EAR) was also evaluated as (EAR = OED type ‘b’ / OED type ‘a’). Results The γ analysis results indicated an acceptable dose distribution agreement of 95% with 3%/3 mm. Although, the γ-maps displayed dose displacement >1 mm around the healthy lungs. Compared to type ‘a’, the OED values from type ‘b’ dose distributions’ were about 8% to 16% higher, leading to an EAR ratio >1, ranged from 1.08 to 1.13 depending on SCR models. Conclusions The shift of dose calculation in radiotherapy, according to the algorithm, can significantly influence the SCR prediction and the plan optimization, since OEDs are calculated from DVH for a specific treatment. The agreement between dose distribution and SCR prediction depends on dose response models and epidemiological data. In addition, the γ passing rates of 3%/3 mm does not translate the difference, up to 15%, in the predictions of SCR resulting from alternative algorithms. Considering that modern algorithms are more accurate, showing more precisely the dose distributions, but that the prediction of absolute SCR is still very imprecise, only the EAR ratio could be used to rank radiotherapy plans. PMID:28811995

  8. Bronchodilator efficacy of tiotropium in patients with mild to moderate COPD.

    PubMed

    Johansson, Gunnar; Lindberg, Anne; Romberg, Kerstin; Nordström, Lars; Gerken, Fronke; Roquet, Annika

    2008-09-01

    Evaluation of tiotropium efficacy in patients with mild chronic obstructive pulmonary disease (COPD) defined by the 2003 Swedish Society of Respiratory Medicine guidelines (post-bronchodilator FEV1/FVC <70%; FEV1 >60% predicted). In this 12-week, randomised, double-blind, placebo-controlled study of tiotropium 18 mcg once daily versus placebo, respiratory function was assessed on Days 1, 15 and 85 (baseline: pre-dose Day 1). Mean+/-SD baseline FEV1 (% predicted) was 73.4+/-12.5 (tiotropium, n=107; placebo, n=117). Tiotropium significantly improved change from baseline in area under the curve from pre-dose to 2 hours post-dose (AUC0-2 h) FEV1 versus placebo, by 166+/-26 mL (mean+/-SE) at study end (p<0.0001). With tiotropium, there were significant increases in the change in AUC0-2 h FVC versus baseline, and trough FEV1 and FVC, versus placebo, on all test days (p<0.01). Adverse event rates were similar. Compared with placebo, tiotropium improved lung function in patients with mild COPD.

  9. Daily radionuclide ingestion and internal radiation doses in Aomori prefecture, Japan.

    PubMed

    Ohtsuka, Yoshihito; Kakiuchi, Hideki; Akata, Naofumi; Takaku, Yuichi; Hisamatsu, Shun'ichi

    2013-10-01

    To assess internal annual dose in the general public in Aomori Prefecture, Japan, 80 duplicate cooked diet samples, equivalent to the food consumed over a 400-d period by one person, were collected from 100 volunteers in Aomori City and the village of Rokkasho during 2006–2010 and were analyzed for 11 radionuclides. To obtain average rates of ingestion of radionuclides, the volunteers were selected from among office, fisheries, agricultural, and livestock farm workers. Committed effective doses from ingestion of the diet over a 1-y period were calculated from the analytical results and from International Commission on Radiological Protection dose coefficients; for 40K, an internal effective dose rate from the literature was used. Fisheries workers had significantly higher combined internal annual dose than the other workers, possibly because of high rates of ingestion of marine products known to have high 210Po concentrations. The average internal dose rate, weighted by the numbers of households in each worker group in Aomori Prefecture, was estimated at 0.47 mSv y-1. Polonium-210 contributed 49% of this value. The sum of committed effective dose rates for 210Po, 210Pb, 228Ra, and 14C and the effective dose rate of 40K accounted for approximately 99% of the average internal dose rate.

  10. Australian patterns of prostate cancer care: Are they evolving?

    PubMed Central

    Lo, Jonathon; Papa, Nathan; Bolton, Damien M.; Murphy, Declan; Lawrentschuk, Nathan

    2015-01-01

    Background Approaches to prostate cancer (PCa) care have changed in recent years out of concern for overdiagnosis and overtreatment. Despite these changes, many patients continue to undergo some form of curative treatment and with a growing perception among multidisciplinary clinicians that more aggressive treatments are being favored. This study examines patterns of PCa care in Australia, focusing on current rates of screening and aggressive interventions that consist of high-dose-rate (HDR) brachytherapy and pelvic lymph node dissection (PLND). Methods Health services data were used to assess Australian men undergoing PCa screening and treatment from 2001 to 2014. Age-specific rates of prostate-specific antigen (PSA) screening were calculated. Ratios of radical prostatectomy (RP) with PLND to RP without PLND, and HDR brachytherapy to low-dose-rate (LDR) brachytherapy were determined by state jurisdictions. Results From 2008, the rate of PSA screening trended downward significantly with year for all age ranges (P < 0.02) except men aged ≥ 85 (P = 0.56). PLND rates for 2008–2014 were lower than rates for 2001–2007 across all states and territories. From 2008 to 2014, PLND was performed ≥ 2.7 times more frequently in New South Wales and the Australian Capital Territory than in other jurisdictions. Since 2007, brachytherapy practice across Australia has evolved towards a relatively low use of HDR brachytherapy (ratio of HDR to LDR brachytherapy < 0.5 for all jurisdictions except the Australian Capital Territory). Conclusion Rates of PLND and HDR brachytherapy for PCa have declined in Australia, providing evidence for the effect of stage migration due to widespread PSA screening. Currently, PSA screening rates remain high among older men, which may expose them to unnecessary investigations and treatment-related morbidity. PMID:27014660

  11. [Dose rate-dependent cellular and molecular effects of ionizing radiation].

    PubMed

    Przybyszewski, Waldemar M; Wideł, Maria; Szurko, Agnieszka; Maniakowski, Zbigniew

    2008-09-11

    The aim of radiation therapy is to kill tumor cells while minimizing damage to normal cells. The ultimate effect of radiation can be apoptotic or necrotic cell death as well as cytogenetic damage resulting in genetic instability and/or cell death. The destructive effects of radiation arise from direct and indirect ionization events leading to peroxidation of macromolecules, especially those present in lipid-rich membrane structures as well as chromatin lipids. Lipid peroxidative end-products may damage DNA and proteins. A characteristic feature of radiation-induced peroxidation is an inverse dose-rate effect (IDRE), defined as an increase in the degree of oxidation(at constant absorbed dose) accompanying a lower dose rate. On the other hand, a low dose rate can lead to the accumulation of cells in G2, the radiosensitive phase of the cell cycle since cell cycle control points are not sensitive to low dose rates. Radiation dose rate may potentially be the main factor improving radiotherapy efficacy as well as affecting the intensity of normal tissue and whole-body side effects. A better understanding of dose rate-dependent biological effects may lead to improved therapeutic intervention and limit normal tissue reaction. The study reviews basic biological effects that depend on the dose rate of ionizing radiation.

  12. Long-Term Effects of Safinamide on Dyskinesia in Mid- to Late-Stage Parkinson's Disease: A Post-Hoc Analysis.

    PubMed

    Cattaneo, Carlo; Ferla, R La; Bonizzoni, Erminio; Sardina, Marco

    2015-01-01

    Safinamide is a novel α-aminoamide with dopaminergic and non-dopaminergic properties developed as adjunctive therapy for patients with PD. Results from a 24-month double-blind controlled study suggested that as add-on to levodopa (and other PD medications) the benefits of safinamide on dyskinesia may be related to severity of dyskinesia at baseline. This post-hoc analysis further characterized the effects of safinamide on dyskinesia in mid- to late-stage PD patients. Patients were stratified by the presence or absence of dyskinesia at baseline, and by whether or not the dose of levodopa had been changed during the 24-month treatment period. Differences between safinamide and placebo were evaluated using the Wilcoxon rank-sum test. For the overall treated population (with or without baseline dyskinesia), safinamide 100 mg/day significantly improved the dyskinesia rating scale score, compared with placebo, in the subgroup of patients with no change in levodopa dose (p = 0.0488). For patients with baseline dyskinesia, improvements over placebo were also significant (p = 0.0153) in patients with or without changes in levodopa dose, and nearly significant (p = 0.0546) in patients with no change in levodopa dose, suggesting that these improvements were not due to levodopa dose reductions. While no statistically significant difference in mean DRS scores was seen between safinamide and placebo in the original study population, the present post-hoc analysis helps to provide a meaningful interpretation of the long-term effects of safinamide on dyskinesia. These results may be related to safinamide state- and use-dependent inhibition of sodium channels and stimulated glutamate release, and are unlikely due to reduced dopaminergic stimulation.

  13. Long-Term Effects of Safinamide on Dyskinesia in Mid- to Late-Stage Parkinson’s Disease: A Post-Hoc Analysis

    PubMed Central

    Cattaneo, Carlo; Ferla, R. La; Bonizzoni, Erminio; Sardina, Marco

    2015-01-01

    Abstract Background: Safinamide is a novel α-aminoamide with dopaminergic and non-dopaminergic properties developed as adjunctive therapy for patients with PD. Results from a 24-month double-blind controlled study suggested that as add-on to levodopa (and other PD medications) the benefits of safinamide on dyskinesia may be related to severity of dyskinesia at baseline. Objective: This post-hoc analysis further characterized the effects of safinamide on dyskinesia in mid- to late-stage PD patients. Methods: Patients were stratified by the presence or absence of dyskinesia at baseline, and by whether or not the dose of levodopa had been changed during the 24-month treatment period. Differences between safinamide and placebo were evaluated using the Wilcoxon rank-sum test. Results: For the overall treated population (with or without baseline dyskinesia), safinamide 100 mg/day significantly improved the dyskinesia rating scale score, compared with placebo, in the subgroup of patients with no change in levodopa dose (p = 0.0488). For patients with baseline dyskinesia, improvements over placebo were also significant (p = 0.0153) in patients with or without changes in levodopa dose, and nearly significant (p = 0.0546) in patients with no change in levodopa dose, suggesting that these improvements were not due to levodopa dose reductions. Conclusions: While no statistically significant difference in mean DRS scores was seen between safinamide and placebo in the original study population, the present post-hoc analysis helps to provide a meaningful interpretation of the long-term effects of safinamide on dyskinesia. These results may be related to safinamide state- and use-dependent inhibition of sodium channels and stimulated glutamate release, and are unlikely due to reduced dopaminergic stimulation. PMID:26406127

  14. Human papillomavirus vaccination coverage in Luxembourg - Implications of lowering and restricting target age groups.

    PubMed

    Latsuzbaia, Ardashel; Arbyn, Marc; Weyers, Steven; Mossong, Joël

    2018-04-25

    In Luxembourg, a national Human Papillomavirus (HPV) vaccination programme was introduced in 2008, targeting 12-17 year old girls offering a choice of bivalent or quadrivalent vaccine free of charge. In 2015, the programme was changed offering the bivalent vaccine only to 11-13 year old girls. The aim of this study was to evaluate the HPV vaccination coverage, to assess the impact of age target changes and compare vaccination coverage to other European countries. Anonymous HPV vaccination records consisting of individual vaccine doses obtained free of charge in pharmacies between 2008 and 2016 were extracted from the Luxembourgish Social Security database. Additional aggregate tables by nationality and municipality were analysed. Of the target cohort of 39,610 girls born between 1991 and 2003 residing in Luxembourg, 24,550 (62.0%) subjects obtained at least one dose, 22,082 (55.7%) obtained at least two doses, and 17,197 (43.4%) obtained three doses of HPV vaccine. The mean age at first dose was 13.7 years during 2008-14 and 12.7 years in 2016 after the age target change. Coverage varied significantly by nationality (p < 0.0001): Portuguese (80%), former Yugoslavs (74%), Luxembourgish (54%), Belgian (52%), German (47%), French (39%) and other nationalities (51%). Coverage varied also by geographical region, with lower rates (<50%) noted in some Northern and Central areas of Luxembourg (range: 38% to 78%). Overall HPV vaccination coverage in Luxembourg is moderate and varied by nationality and region. The policy changes in 2015 did not have a substantial impact except lowering age at initiating vaccination. Options to improve coverage deserve further investigation. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  15. A prospective randomized, double-dummy trial comparing IV push low dose ketamine to short infusion of low dose ketamine for treatment of  pain in the ED.

    PubMed

    Motov, Sergey; Mai, Mo; Pushkar, Illya; Likourezos, Antonios; Drapkin, Jefferson; Yasavolian, Matthew; Brady, Jason; Homel, Peter; Fromm, Christian

    2017-08-01

    Compare adverse effects and analgesic efficacy of low-dose ketamine for acute pain in the ED administered either by single intravenous push (IVP) or short infusion (SI). Patients 18-65, presenting to ED with acute abdominal, flank, or musculoskeletal pain with initial pain score≥5, were randomized to ketamine 0.3mg/kg by either IVP or SI with placebo double-dummy. Adverse effects were evaluated by Side Effects Rating Scale for Dissociative Anesthetics (SERSDA) and Richmond Agitation-Sedation Scale (RASS) at 5, 15, 30, 60, 90, and 120min post-administration; analgesic efficacy was evaluated by Numerical Rating Scale (NRS). 48 patients enrolled in the study. IVP group had higher overall rates of feeling of unreality on SERSDA scale: 92% versus 54% (difference 37.5%; p=0.008; 95% CI 9.3-59.5%). At 5min median severity of feeling of unreality was 3.0 for IVP versus 0.0 for SI (p=0.001). IVP also showed greater rates of sedation on RASS scale at 5min: median RASS -2.0 versus 0.0 (p=0.01). Decrease in mean pain scores from baseline to 15min was similar across groups: 5.2±3.53 (95% CI 3.7-6.7) for IVP; 5.75±3.48 (95% CI 4.3-7.2) for SI. There were no statistically significant differences with respect to changes in vital signs and need for rescue medication. Low-dose ketamine given as a short infusion is associated with significantly lower rates of feeling of unreality and sedation with no difference in analgesic efficacy in comparison to intravenous push. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Dose rate effects on array CCDs exposed by Co-60 γ rays induce saturation output degradation and annealing tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Zujun, E-mail: wangzujun@nint.ac.cn; Chen, Wei; He, Baoping

    The experimental tests of dose rate and annealing effects on array charge-coupled devices (CCDs) are presented. The saturation output voltage (V{sub S}) versus the total dose at the dose rates of 0.01, 0.1, 1.0, 10.0 and 50 rad(Si)/s are compared. Annealing tests are performed to eliminate the time-dependent effects. The V{sub S} degradation levels depend on the dose rates. The V{sub S} degradation mechanism induced by dose rate and annealing effects is analyzed. The V{sub S} at 20 krad(Si) with the dose rate of 0.03 rad(Si)/s are supplemented to assure the degradation curves between the dose rates of 0.1 andmore » 0.01 rad(Si)/s. The CCDs are divided into two groups, with one group biased and the other unbiased during {sup 60}Co γ radiation. The V{sub S} degradation levels of the biased CCDs during radiation are more severe than that of the unbiased CCDs.« less

  17. Measurement of ambient dose equivalent rates by walk survey around Fukushima Dai-ichi Nuclear Power Plant using KURAMA-II until 2016.

    PubMed

    Andoh, Masaki; Yamamoto, Hideaki; Kanno, Takashi; Saito, Kimiaki

    2018-05-17

    Ambient dose equivalent rates in various environments related to human lives were measured by walk surveys using the KURAMA-II systems from 2013 to 2016 within an 80-km radius of the Fukushima Dai-ichi Nuclear Power Plant. The dose rate of the locations where the walk survey was performed decreased to about 38% of its initial value in the 42 months from June 2013 to the December 2016, which was beyond that attributable to the physical decay of radiocaesium. The ecological half-life of the slow decreasing component was evaluated to be 4.1 ± 0.2 y. The air dose rates decreased depending on the level of the evacuation areas, and the decrease in the dose rates was slightly larger in populated areas where humans are active. The dose rates as measured by walk surveys exhibited a good correlation with those by car-borne surveys, suggesting that car-borne survey data are reflecting the air dose rates in living environments surrounding roads. The comparison of walk survey data with car-borne survey data indicated that the air dose rate varies largely even within a 100 m square area, and the variation is enhanced by human activities. The dose rates measured by the walk surveys were estimated to be medial of those along roads and those of undisturbed flat ground, and they were found to be decreasing quickly compared with the air dose rate from the flat ground fixed-point measurements. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    PubMed

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  19. OPERATIONAL CHARACTERISTICS OF THE ARMOUR FISSION GAS GAMMA FACILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terrell, C.W.; McElroy, W.N.

    1958-10-31

    As the reactor power level is changed frequently, the radiation levels in the gamma facility fluctuate. Data are presented to show the power dependency of the gamma dose rate and the manner of growth and decay. Additional data show the dependercy of the equilibrium gamma activity on the foel temperature and total system pressure. The final phase of the work is directed toward determining an average gamma energy by attenuation measurements with various thicknesses of several materials. The neutrou flux associated with the gas phase activity is determined by foil measurement. From the measurements of dose rate and average gammamore » energy, calculations to determine the number of curies of gas phase decay gamma activity per watt of reactor power are presented. (auth)« less

  20. Immediate effects of 33 to 180 rad/min (60)Co exposure on performance and blood pressure in monkeys. Topical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bruner, A.

    1976-09-01

    Four groups of monkeys received 1000 rads (60)Co at 33, 50, 75, or 180 rad/min wholebody irradiation while performing a delayed matching-to-sample task. Systematic dose rate effects were observed on performance and blood pressure within the initial 20 min postirradiation. The incidence and severity of performance decrement (PD) increased with higher dose rate. The appearance of postirradiation hypotension was systematically delayed and its rate of fall prolonged as dose rate was lower. The hypotension likewise appeared less deep with lower dose rate exposure. Based on the calculated cumulative dose absorbed at the time of symptom appearance two coactive thresholds weremore » proposed to exist: a total dose threshold of approximately 300 rads (midbody measurement), and a dose rate threshold of about 25 rad/min.« less

  1. [Study of mumps immunity after administrating measles-mumps-rubella vaccine among children aged 2-7 years old in Jiangsu Province in 2015].

    PubMed

    Liu, Y B; Hu, Y; Deng, X Y; Wang, Z G; Sun, X; Lu, P S; Guo, H X; Tang, F Y; Zhou, M H

    2017-07-06

    Objective: To investigate the immunity to mumps after administrating measles-mumps-rubella vaccine (MMR) among children aged 2-7 years old in Jiangsu province in 2015. Methods: A total of 4 190 healthy children aged 2-7 years old, living in local places for at least 3 months, and having been vaccinated at least 1 dose MMR were recruited to the study from Wujin district of Changzhou city, Gaogang district of Taizhou city and Ganyu district of Lianyungang city by using stratified cluster random sampling method between September and November, 2015. Those who did not accept MMR vaccination, who refused venous blood collection, who had affected mumps according to the memory of parents or teachers and who were diagnosed serious disease by clinical doctors were excluded from study. The self-designed questionnaire was used to collect the general information of the subjects and their MMR immunization history; and 0.5-2.0 ml of venous blood was collected from each subject. ELISA was used to detect the mumps antibody level in the serum of patients. Positive was defined as the antibody level ≥108 mU/ml, and negative as <108 mU/ml. χ(2) test was used to compare the difference in positive rates among subjects; and analysis of variance was used to compare the GMC changes in different time points after MMR vaccination. Results: Among 4 190 children, 2 280 were males (54.42%) and 1 910 were females(45.58%), and the positive rate of IgG antibody was 81.38% (3 344). There were 3 156 (95.18%) children vaccinated with one dose MMR, 187 (4.80%) children with two dose MMR, and 1 (0.02%) child with three dose MMR. The difference in positive rate of IgG antibody among different aged subjects showed statistical significance (χ(2)=58.61, P< 0.001), the highest positive rate was in group of subjects aged 4-5 years old, at 89.43% (406/454), while the lowest positive rate was found among subjects aged 6-7 years old, at 75.63% (1 648/2 179). The positive rate after one dose of MMR vaccination was 79.14% (3 156/3 988), significantly less than it after two doses (93.03%, 187/201) (χ(2)=22.93, P< 0.001). The GMC level at years<1, 1-<2, 2-<3, 3-<4, ≥4 following one dose MMR in the 3 988 children was 152.47, 227.78, 167.08, 126.91, 79.43 mU/ml, whose difference was statistically significant ( F= 51.29, P< 0.001). Conclusion: The sero-prevalence of IgG antibody in the children aged 2-7 years old in Jiangsu province was high. The positive rate among who received two doses MMR was significantly higher than it among who received just one dose, and the GMC level waned with times.

  2. The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rau, A.W.; Bakueva, L.; Rowlands, J.A.

    2005-10-15

    Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristics of FPIs can be affected by ghosting (i.e., radiation-induced changes of sensitivity) when the dose to the detector is high (e.g., portal imaging and mammography) or the images are acquired at a high frame rate (e.g., fluoroscopy). In this paper, the x-ray time-of-flight (TOF) method is introduced as a tool for the investigation of ghosting inmore » a-Se photoconductor layers. The method consists of irradiating layers of a-Se with short x-ray pulses. From the current generated in the a-Se layer, ghosting is quantified and the ghosting parameters (charge carrier generation rate and carrier lifetimes and mobilities) are assessed. The x-ray TOF method is novel in that (1) x-ray sensitivity (S) and ghosting parameters can be measured simultaneously (2) the transport of both holes and electrons can be isolated, and (3) the method is applicable to the practical a-Se layer structure with blocking contacts used in FPIs. The x-ray TOF method was applied to an analysis of ghosting in a-Se photoconductor layers under portal imaging conditions, i.e., 1 mm thick a-Se layers, biased at 5 V/{mu}m, were irradiated using a 6 MV LINAC x-ray beam to a total dose (ghosting dose) of 30 Gy. The initial sensitivity (S{sub 0}) of the a-Se layers was 63{+-}2 nC cm{sup -2} cGy{sup -1}. It was found that S decreases to 30% of S{sub 0} after a ghosting dose of 5 Gy and to 21% after 30 Gy at which point no further change in S occurs. At an x-ray intensity of 22 Gy/s (instantaneous dose rate during a LINAC x-ray pulse), the charge carrier generation rate was 1.25{+-}0.1x10{sup 22} ehp m{sup -3} s{sup -1} and, to a first approximation, independent of the ghosting dose. However, both hole and electron transport showed a strong dependence on the ghosting dose: hole transport decreased by 61%, electron transport by up to {approx}80%. Therefore, degradation of both hole and electron transport due to the recombination of mobile charge carriers with trapped carriers (of opposite polarity) were identified as the main cause of ghosting in this study.« less

  3. [Effects of shoutai pills on expression of Th1/Th2 cytokine in maternal-fetal interface and pregnancy outcome].

    PubMed

    Lai, Maohua; You, Zhaoling; Ma, Hongxia; Lei, Lei; Lu, Fangguo; He, Dongmei; Liu, Huiping; Yin, Sheng

    2010-11-01

    To evaluate its mechanism of inducing the maternal-fetal immune tolerance by studying the effects of Shoutai pills on the expression of Th1/Th2 cytokine and pregnancy in maternal-fetal interface of mice with recurrent spontaneous abortion (RSA). The normal pregnancy and RSA model were respectively induced with CBA/J x BALB/c and CBA/J x DBA/2. The mice with RSA were randomly divided into model group and low, middle and high dose groups of Shoutai pills. The mice were killed in 14 days after administration and embryo resorption rate was counted and their decidual and placental tissues were co-cultured to detect the expressions of IL-4, IL-10, IFN-gamma and TNF-alpha with ELISA. The embryo resorption rate of the model group was significantly higher than the normal pregnancy, middle and high dose groups of Shoutai pills could decreased the embryo resorption rate of the mice with RSA (P < 0.05). All the doses in 3 groups of Shoutai pills could decreased the expression of IFN-gamma and TNF-alpha (P < 0. 05) and there was no obvious difference between normal pregnancy group and all groups of Shoutai pills. Middle and high doses of Shoutai pills could increased the expression of IL-4 and IL-10 (P < 0.05) and there was no obvious differences between normal pregnancy and high dose group of Shoutai pills. The mechanism about Shoutai pills can change Th1 /Th2 cytokine towards Th2 bias, which induced the maternal-fetal immune tolerance.

  4. Variation of indoor radon concentration and ambient dose equivalent rate in different outdoor and indoor environments.

    PubMed

    Stojanovska, Zdenka; Boev, Blazo; Zunic, Zora S; Ivanova, Kremena; Ristova, Mimoza; Tsenova, Martina; Ajka, Sorsa; Janevik, Emilija; Taleski, Vaso; Bossew, Peter

    2016-05-01

    Subject of this study is an investigation of the variations of indoor radon concentration and ambient dose equivalent rate in outdoor and indoor environments of 40 dwellings, 31 elementary schools and five kindergartens. The buildings are located in three municipalities of two, geologically different, areas of the Republic of Macedonia. Indoor radon concentrations were measured by nuclear track detectors, deployed in the most occupied room of the building, between June 2013 and May 2014. During the deploying campaign, indoor and outdoor ambient dose equivalent rates were measured simultaneously at the same location. It appeared that the measured values varied from 22 to 990 Bq/m(3) for indoor radon concentrations, from 50 to 195 nSv/h for outdoor ambient dose equivalent rates, and from 38 to 184 nSv/h for indoor ambient dose equivalent rates. The geometric mean value of indoor to outdoor ambient dose equivalent rates was found to be 0.88, i.e. the outdoor ambient dose equivalent rates were on average higher than the indoor ambient dose equivalent rates. All measured can reasonably well be described by log-normal distributions. A detailed statistical analysis of factors which influence the measured quantities is reported.

  5. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    PubMed

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Effects of Low-Dose and Very Low-Dose Ketamine among Patients with Major Depression: a Systematic Review and Meta-Analysis.

    PubMed

    Xu, Ying; Hackett, Maree; Carter, Gregory; Loo, Colleen; Gálvez, Verònica; Glozier, Nick; Glue, Paul; Lapidus, Kyle; McGirr, Alexander; Somogyi, Andrew A; Mitchell, Philip B; Rodgers, Anthony

    2016-04-01

    Several recent trials indicate low-dose ketamine produces rapid antidepressant effects. However, uncertainty remains in several areas: dose response, consistency across patient groups, effects on suicidality, and possible biases arising from crossover trials. A systematic search was conducted for relevant randomized trials in Medline, Embase, and PsycINFO databases up to August 2014. The primary endpoints were change in depression scale scores at days 1, 3 and 7, remission, response, suicidality, safety, and tolerability. Data were independently abstracted by 2 reviewers. Where possible, unpublished data were obtained on treatment effects in the first period of crossover trials. Nine trials were identified, including 201 patients (52% female, mean age 46 years). Six trials assessed low-dose ketamine (0.5 mg/kg i.v.) and 3 tested very low-dose ketamine (one trial assessed 50 mg intra-nasal spray, another assessed 0.1-0.4 mg/kg i.v., and another assessed 0.1-0.5 mg/kg i.v., intramuscular, or s.c.). At day 3, the reduction in depression severity score was less marked in the very low-dose trials (P homogeneity <.05) and among bipolar patients. In analyses excluding the second period of crossover trials, response rates at day 7 were increased with ketamine (relative risk 3.4, 95% CI 1.6-7.1, P=.001), as were remission rates (relative risk 2.6, CI 1.2-5.7, P=.02). The absolute benefits were large, with day 7 remission rates of 24% vs 6% (P=.02). Seven trials provided unpublished data on suicidality item scores, which were reduced on days 1 and 3 (both P<.01) but not day 7. Low-dose ketamine appears more effective than very low dose. There is substantial heterogeneity in clinical response, with remission among one-fifth of patients at 1 week but most others having benefits that are less durable. Larger, longer term parallel group trials are needed to determine if efficacy can be extended and to further assess safety. © The Author 2015. Published by Oxford University Press on behalf of CINP.

  7. Effects of Low-Dose and Very Low-Dose Ketamine among Patients with Major Depression: a Systematic Review and Meta-Analysis

    PubMed Central

    Xu, Ying; Hackett, Maree; Carter, Gregory; Gálvez, Verònica; Glozier, Nick; Glue, Paul; Lapidus, Kyle; McGirr, Alexander; Somogyi, Andrew A.; Mitchell, Philip B.; Rodgers, Anthony

    2016-01-01

    Background: Several recent trials indicate low-dose ketamine produces rapid antidepressant effects. However, uncertainty remains in several areas: dose response, consistency across patient groups, effects on suicidality, and possible biases arising from crossover trials. Methods: A systematic search was conducted for relevant randomized trials in Medline, Embase, and PsycINFO databases up to August 2014. The primary endpoints were change in depression scale scores at days 1, 3 and 7, remission, response, suicidality, safety, and tolerability. Data were independently abstracted by 2 reviewers. Where possible, unpublished data were obtained on treatment effects in the first period of crossover trials. Results: Nine trials were identified, including 201 patients (52% female, mean age 46 years). Six trials assessed low-dose ketamine (0.5mg/kg i.v.) and 3 tested very low-dose ketamine (one trial assessed 50mg intra-nasal spray, another assessed 0.1–0.4mg/kg i.v., and another assessed 0.1–0.5mg/kg i.v., intramuscular, or s.c.). At day 3, the reduction in depression severity score was less marked in the very low-dose trials (P homogeneity <.05) and among bipolar patients. In analyses excluding the second period of crossover trials, response rates at day 7 were increased with ketamine (relative risk 3.4, 95% CI 1.6–7.1, P=.001), as were remission rates (relative risk 2.6, CI 1.2–5.7, P=.02). The absolute benefits were large, with day 7 remission rates of 24% vs 6% (P=.02). Seven trials provided unpublished data on suicidality item scores, which were reduced on days 1 and 3 (both P<.01) but not day 7. Conclusion: Low-dose ketamine appears more effective than very low dose. There is substantial heterogeneity in clinical response, with remission among one-fifth of patients at 1 week but most others having benefits that are less durable. Larger, longer term parallel group trials are needed to determine if efficacy can be extended and to further assess safety. PMID:26578082

  8. Micronucleus induction in Vicia faba roots. Part 1. Absence of dose-rate, fractionation, and oxygen effect at low doses of low LET radiations.

    PubMed

    Marshall, I; Bianchi, M

    1983-08-01

    Micronucleus indication in Vicia faba roots has been evaluated after irradiation with 60Co gamma-rays. The dependence of the damage on dose, dose rate, fractionation, and oxygen has been studied. The best fit to the experimental data in the dose region between 7 and 190 cGy is represented, for single-dose exposures, by a linear + quadratic relationship. In the low-dose region, between 7 and 20 cGy, where the linear dose dependence is dominant, no dose-rate, fractionation, or oxygen effect could be observed. These effects were, however, present in the high-dose region, where the quadratic dependence is dominant.

  9. Low and high dose rate heavy ion radiation-induced intestinal and colonic tumorigenesis in APC1638N/+ mice

    NASA Astrophysics Data System (ADS)

    Suman, Shubhankar; Kumar, Santosh; Moon, Bo-Hyun; Fornace, Albert J.; Datta, Kamal

    2017-05-01

    Ionizing radiation (IR) is a recognized risk factor for colorectal cancer (CRC) and astronauts undertaking long duration space missions are expected to receive IR doses in excess of permissible limits with implications for colorectal carcinogenesis. Exposure to IR in outer space occurs at low doses and dose rates, and energetic heavy ions due to their high linear energy transfer (high-LET) characteristics remain a major concern for CRC risk in astronauts. Previously, we have demonstrated that intestinal tumorigenesis in a mouse model (APC1638N/+) of human colorectal cancer was significantly higher after exposure to high dose rate energetic heavy ions relative to low-LET γ radiation. The purpose of the current study was to compare intestinal tumorigenesis in APC1638N/+ mice after exposure to energetic heavy ions at high (50 cGy/min) and relatively low (0.33 cGy/min) dose rate. Male and female mice (6-8 weeks old) were exposed to either 10 or 50 cGy of 28Si (energy: 300 MeV/n; LET: 70 keV/μm) or 56Fe (energy: 1000 MeV/n; LET: 148 keV/μm) ions at NASA Space Radiation Laboratory in Brookhaven National Laboratory. Mice (n = 20 mice/group) were euthanized and intestinal and colon tumor frequency and size were counted 150 days after radiation exposure. Intestinal tumorigenesis in male mice exposed to 56Fe was similar for high and low dose rate exposures. Although male mice showed a decreasing trend at low dose rate relative to high dose rate exposures, the differences in tumor frequency between the two types of exposures were not statistically significant after 28Si radiation. In female mice, intestinal tumor frequency was similar for both radiation type and dose rates tested. In both male and female mice intestinal tumor size was not different after high and low dose rate radiation exposures. Colon tumor frequency in male and female mice after high and low dose rate energetic heavy ions was also not significantly different. In conclusion, intestinal and colonic tumor frequency and size was similar irrespective of energetic heavy ion radiation dose rate suggesting that carcinogenic potential of energetic heavy ions is independent of dose rate.

  10. Evaluation of Dose Uncertainty to the Target Associated With Real-Time Tracking Intensity-Modulated Radiation Therapy Using the CyberKnife Synchrony System.

    PubMed

    Iwata, Hiromitsu; Inoue, Mitsuhiro; Shiomi, Hiroya; Murai, Taro; Tatewaki, Koshi; Ohta, Seiji; Okawa, Kohei; Yokota, Naoki; Shibamoto, Yuta

    2016-02-01

    We investigated the dose uncertainty caused by errors in real-time tracking intensity-modulated radiation therapy (IMRT) using the CyberKnife Synchrony Respiratory Tracking System (SRTS). Twenty lung tumors that had been treated with non-IMRT real-time tracking using CyberKnife SRTS were used for this study. After validating the tracking error in each case, we did 40 IMRT planning using 8 different collimator sizes for the 20 patients. The collimator size was determined for each planning target volume (PTV); smaller ones were one-half, and larger ones three-quarters, of the PTV diameter. The planned dose was 45 Gy in 4 fractions prescribed at 95% volume border of the PTV. Thereafter, the tracking error in each case was substituted into calculation software developed in house and randomly added in the setting of each beam. The IMRT planning incorporating tracking errors was simulated 1000 times, and various dose data on the clinical target volume (CTV) were compared with the original data. The same simulation was carried out by changing the fraction number from 1 to 6 in each IMRT plan. Finally, a total of 240 000 plans were analyzed. With 4 fractions, the change in the CTV maximum and minimum doses was within 3.0% (median) for each collimator. The change in D99 and D95 was within 2.0%. With decreases in the fraction number, the CTV coverage rate and the minimum dose decreased and varied greatly. The accuracy of real-time tracking IMRT delivered in 4 fractions using CyberKnife SRTS was considered to be clinically acceptable. © The Author(s) 2014.

  11. An open-label, dose-titration tolerability study of atomoxetine hydrochloride in Japanese adults with attention-deficit/hyperactivity disorder.

    PubMed

    Takahashi, Michihiro; Takita, Yasushi; Goto, Taro; Ichikawa, Hironobu; Saito, Kazuhiko; Matsumoto, Hideo; Tanaka, Yasuo

    2011-02-01

    The main purpose of this first atomoxetine study in Japanese adults with attention-deficit/hyperactivity disorder (ADHD) was to investigate the tolerability of an 8-week treatment regimen. This was an open-label, dose escalation study conducted in 45 Japanese patients aged at least 18 years with DSM-IV-defined ADHD. Patients received atomoxetine orally for 8 weeks. Atomoxetine administration was started at 40 mg/day (7 days), and subsequently increased to a maximum dose of 120 mg/day. Tolerability was assessed by discontinuation rate due to adverse events. Adverse events, laboratory tests, vital signs and electrocardiograms were collected. In addition, ADHD symptoms were assessed by using the Japanese version of the Conners' Adult ADHD Rating Scale-Investigator Rated: Screening Version (CAARS-Inv:SV) scores. Thirty-nine patients completed the study period. Atomoxetine was well tolerated with a 6.7% (3/45) discontinuation rate due to nausea, malaise and anorexia. The most commonly reported adverse events were nausea, nasopharyngitis and headache; there were no unexpected safety concerns. No deaths or serious adverse events were reported. Mean CAARS-Inv:SV-J total ADHD symptom scores decreased in a time-dependent manner; the mean change from baseline to endpoint was -15.0 (P<0.001). This study showed that atomoxetine was well tolerated in these patients and suggested that atomoxetine at a maximum dose of 120 mg/day would be safe in Japanese ADHD patients. © 2011 The Authors. Psychiatry and Clinical Neurosciences © 2011 Japanese Society of Psychiatry and Neurology.

  12. Fractionated Stereotactic Radiotherapy of Vestibular Schwannomas Accelerates Hearing Loss

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rasmussen, Rune, E-mail: rune333@gmail.com; Claesson, Magnus; Stangerup, Sven-Eric

    2012-08-01

    Objective: To evaluate long-term tumor control and hearing preservation rates in patients with vestibular schwannoma treated with fractionated stereotactic radiotherapy (FSRT), comparing hearing preservation rates to an untreated control group. The relationship between radiation dose to the cochlea and hearing preservation was also investigated. Methods and Materials: Forty-two patients receiving FSRT between 1997 and 2008 with a minimum follow-up of 2 years were included. All patients received 54 Gy in 27-30 fractions during 5.5-6.0 weeks. Clinical and audiometry data were collected prospectively. From a 'wait-and-scan' group, 409 patients were selected as control subjects, matched by initial audiometric parameters. Radiation dosemore » to the cochlea was measured using the original treatment plan and then related to changes in acoustic parameters. Results: Actuarial 2-, 4-, and 10-year tumor control rates were 100%, 91.5%, and 85.0%, respectively. Twenty-one patients had serviceable hearing before FSRT, 8 of whom (38%) retained serviceable hearing at 2 years after FSRT. No patients retained serviceable hearing after 10 years. At 2 years, hearing preservation rates in the control group were 1.8 times higher compared with the group receiving FSRT (P=.007). Radiation dose to the cochlea was significantly correlated to deterioration of the speech reception threshold (P=.03) but not to discrimination loss. Conclusion: FSRT accelerates the naturally occurring hearing loss in patients with vestibular schwannoma. Our findings, using fractionation of radiotherapy, parallel results using single-dose radiation. The radiation dose to the cochlea is correlated to hearing loss measured as the speech reception threshold.« less

  13. Evaluation of Gamma Radiation-Induced Biochemical Changes in Skin for Dose Assesment: A Study on Small Experimental Animals.

    PubMed

    Kumar Soni, Sandeep; Basu, Mitra; Agrawal, Priyanka; Bhatnagar, Aseem; Chhillar, Neelam

    2018-05-24

    Researchers have been evaluating several approaches to assess acute radiation injury/toxicity markers owing to radiation exposure. Keeping in mind this background, we assumed that whole-body irradiation in single fraction in graded doses can affect the antioxidant profile in skin that could be used as an acute radiation injury/toxicity marker. Sprague-Dawley rats were treated with CO-60 gamma radiation (dose: 1-5 Gy; dose rate: 0.85 Gy/minute). Skin samples were collected (before and after radiation up to 72 hours) and analyzed for glutathione (GSH), glutathione peroxidase (GPx), superoxide dismutase (SOD), catalase (CAT), and lipid peroxidation (LPx). Intra-group comparison showed significant differences in GSH, GPx, SOD, and CAT, and they declined in a dose-dependent manner from 1 to 5 Gy (P value0.05). This study suggests that skin antioxidants were sensitive toward radiation even at a low radiation dose, which can be used as a predictor of radiation injury and altered in a dose-dependent manner. These biochemical parameters may have wider application in the evaluation of radiation-induced skin injury and dose assessment. (Disaster Med Public Health Preparedness. 2018;page 1 of 6).

  14. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation.

    PubMed

    Tran, Van; Little, Mark P

    2017-11-01

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and non-malignant, show downward curvature in the dose response, and for most endpoints this is statistically significant (p < 0.05). Associated with this, the low-dose extrapolation factor associated with neutron exposure is generally statistically significantly less than 1 for most malignant and non-malignant endpoints, with central estimates mostly in the range 0.1-0.9. In contrast to the situation at higher dose rates, there are statistically non-significant decreases of risk per unit dose at gamma dose rates of less than or equal to 5 mGy/h for most malignant endpoints, and generally non-significant increases in risk per unit dose at gamma dose rates ≤5 mGy/h for most non-malignant endpoints. Associated with this, the dose-rate extrapolation factor, the ratio of high dose-rate to low dose-rate (≤5 mGy/h) gamma dose response slopes, for many tumour sites is in the range 1.2-2.3, albeit not statistically significantly elevated from 1, while for most non-malignant endpoints the gamma dose-rate extrapolation factor is less than 1, with most estimates in the range 0.2-0.8. After neutron exposure there are non-significant indications of lower risk per unit dose at dose rates ≤5 mGy/h compared to higher dose rates for most malignant endpoints, and for all tumours (p = 0.001), and respiratory tumours (p = 0.007) this reduction is conventionally statistically significant; for most non-malignant outcomes risks per unit dose non-significantly increase at lower dose rates. Associated with this, the neutron dose-rate extrapolation factor is less than 1 for most malignant and non-malignant endpoints, in many cases statistically significantly so, with central estimates mostly in the range 0.0-0.2.

  15. Immunoprotective effects of oral intake of heat-killed Lactobacillus pentosus strain b240 in elderly adults: a randomised, double-blind, placebo-controlled trial.

    PubMed

    Shinkai, Shoji; Toba, Masamichi; Saito, Takao; Sato, Ikutaro; Tsubouchi, Mina; Taira, Kiyoto; Kakumoto, Keiji; Inamatsu, Takashi; Yoshida, Hiroto; Fujiwara, Yoshinori; Fukaya, Taro; Matsumoto, Tetsuya; Tateda, Kazuhiro; Yamaguchi, Keizo; Kohda, Noriyuki; Kohno, Shigeru

    2013-05-28

    Oral intake of Lactobacillus pentosus strain b240 (b240) has been shown to enhance the secretion of salivary secretory IgA in elderly adults. However, its clinical benefits remain to be determined. We tested the hypothesis that b240 exerts a protective effect against the common cold in elderly adults. The design of the present study was a randomised, double-blind, placebo-controlled trial (RCT) with parallel three-group comparison. For this purpose, 300 eligible elderly adults were randomly allocated to one of three groups, namely a placebo, low-dose or high-dose b240 group. Participants in the low-dose and high-dose b240 groups were given tablets containing 2 × 10(9) or 2 × 10(10) cells, respectively, of heat-killed b240, while those in the placebo group were given tablets without b240. Each group consumed their respective tablets once daily for 20 weeks. The common cold was assessed on the basis of a diary. Change in quality of life was evaluated using the SF-36. Of the total participants, 280 completed the 20-week RCT. The accumulated incidence rate of the common cold was 47·3, 34·8 and 29·0 % for the placebo, low-dose b240 and high-dose b240 groups, respectively (P for trend = 0·012). Lower incidence rates were consistently observed throughout the experimental period in the b240 groups (log-rank test, P= 0·034). General health perception, as determined by the SF-36®, dose-dependently increased in the b240 groups ( P <0·025). In conclusion, oral intake of b240 significantly reduced the incidence rate of the common cold in elderly adults, indicating that b240 might be useful in improving resistance against infection through mucosal immunity.

  16. A novel predictive pharmacokinetic/pharmacodynamic model of repolarization prolongation derived from the effects of terfenadine, cisapride and E-4031 in the conscious chronic av node--ablated, His bundle-paced dog.

    PubMed

    Nolan, Emily R; Feng, Meihua Rose; Koup, Jeffrey R; Liu, Jing; Turluck, Daniel; Zhang, Yiqun; Paulissen, Jerome B; Olivier, N Bari; Miller, Teresa; Bailie, Marc B

    2006-01-01

    Terfenadine, cisapride, and E-4031, three drugs that prolong ventricular repolarization, were selected to evaluate the sensitivity of the conscious chronic atrioventricular node--ablated, His bundle-paced Dog for defining drug induced cardiac repolarization prolongation. A novel predictive pharmacokinetic/pharmacodynamic model of repolarization prolongation was generated from these data. Three male beagle dogs underwent radiofrequency AV nodal ablation, and placement of a His bundle-pacing lead and programmable pacemaker under anesthesia. Each dog was restrained in a sling for a series of increasing dose infusions of each drug while maintained at a constant heart rate of 80 beats/min. RT interval, a surrogate for QT interval in His bundle-paced dogs, was recorded throughout the experiment. E-4031 induced a statistically significant RT prolongation at the highest three doses. Cisapride resulted in a dose-dependent increase in RT interval, which was statistically significant at the two highest doses. Terfenadine induced a dose-dependent RT interval prolongation with a statistically significant change occurring only at the highest dose. The relationship between drug concentration and RT interval change was described by a sigmoid E(max) model with an effect site. Maximum RT change (E(max)), free drug concentration at half of the maximum effect (EC(50)), and free drug concentration associated with a 10 ms RT prolongation (EC(10 ms)) were estimated. A linear correlation between EC(10 ms) and HERG IC(50) values was identified. The conscious dog with His bundle-pacing detects delayed cardiac repolarization related to I(Kr) inhibition, and detects repolarization change induced by drugs with activity at multiple ion channels. A clinically relevant sensitivity and a linear correlation with in vitro HERG data make the conscious His bundle-paced dog a valuable tool for detecting repolarization effect of new chemical entities.

  17. Poster — Thur Eve — 15: Improvements in the stability of the tomotherapy imaging beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belec, J

    2014-08-15

    Use of helical TomoTherapy based MVCT imaging for adaptive planning requires the image values (HU) to remain stable over the course of treatment. In the past, the image value stability was suboptimal, which required frequent change to the image value to density calibration curve to avoid dose errors on the order of 2–4%. The stability of the image values at our center was recently improved by stabilizing the dose rate of the machine (dose control servo) and performing daily MVCT calibration corrections. In this work, we quantify the stability of the image values over treatment time by comparing patient treatmentmore » image density derived using MVCT and KVCT. The analysis includes 1) MVCT - KVCT density difference histogram, 2) MVCT vs KVCT density spectrum, 3) multiple average profile density comparison and 4) density difference in homogeneous locations. Over two months, the imaging beam stability was compromised several times due to a combination of target wobbling, spectral calibration, target change and magnetron issues. The stability of the image values were analyzed over the same period. Results show that the impact on the patient dose calculation is 0.7% +− 0.6%.« less

  18. Comparison of gamma radiation effects on natural corn and potato starches and modified cassava starch

    NASA Astrophysics Data System (ADS)

    Teixeira, Bruna S.; Garcia, Rafael H. L.; Takinami, Patricia Y. I.; del Mastro, Nelida L.

    2018-01-01

    The objective of this work was to evaluate the effect of irradiation treatment on physicochemical properties of three natural polymers, i.e. native potato and corn starches and a typical Brazilian product, cassava starch modified through fermentation -sour cassava- and also to prepare composite hydrocolloid films based on them. Starches were irradiated in a 60Co irradiation chamber in doses up to 15 kGy, dose rate about 1 kGy/h. Differences were found in granule size distribution upon irradiation, mainly for corn and cassava starch but radiation did not cause significant changes in granule morphology. The viscosity of the potato, corn and cassava starches hydrogels decreased as a function of absorbed dose. Comparing non-irradiated and irradiated starches, changes in the Fourier transform infrared (FTIR) spectra in the 2000-1500 cm-1 region for potato and corn starches were observed but not for the cassava starch. Maximum rupture force of the starch-based films was affected differently for each starch type; color analysis showed that doses of 15 kGy promoted a slight rise in the parameter b* (yellow color) while the parameter L* (lightness) was not significantly affected; X-ray diffraction patterns remained almost unchanged by irradiation.

  19. TU-G-BRA-03: Predicting Radiation Therapy Induced Ventilation Changes Using 4DCT Jacobian Calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, T; Du, K; Bayouth, J

    2015-06-15

    Purpose: Longitudinal changes in lung ventilation following radiation therapy can be mapped using four-dimensional computed tomography(4DCT) and image registration. This study aimed to predict ventilation changes caused by radiation therapy(RT) as a function of pre-RT ventilation and delivered dose. Methods: 4DCT images were acquired before and 3 months after radiation therapy for 13 subjects. Jacobian ventilation maps were calculated from the 4DCT images, warped to a common coordinate system, and a Jacobian ratio map was computed voxel-by-voxel as the ratio of post-RT to pre-RT Jacobian calculations. A leave-one-out method was used to build a response model for each subject: post-RTmore » to pre-RT Jacobian ratio data and dose distributions of 12 subjects were applied to the subject’s pre-RT Jacobian map to predict the post-RT Jacobian. The predicted Jacobian map was compared to the actual post-RT Jacobian map to evaluate efficacy. Within this cohort, 8 subjects had repeat pre-RT scans that were compared as a reference for no ventilation change. Maps were compared using gamma pass rate criteria of 2mm distance-to-agreement and 6% ventilation difference. Gamma pass rates were compared using paired t-tests to determine significant differences. Further analysis masked non-radiation induced changes by excluding voxels below specified dose thresholds. Results: Visual inspection demonstrates the predicted post-RT ventilation map is similar to the actual map in magnitude and distribution. Quantitatively, the percentage of voxels in agreement when excluding voxels receiving below specified doses are: 74%/20Gy, 73%/10Gy, 73%/5Gy, and 71%/0Gy. By comparison, repeat scans produced 73% of voxels within the 6%/2mm criteria. The agreement of the actual post-RT maps with the predicted maps was significantly better than agreement with pre-RT maps (p<0.02). Conclusion: This work validates that significant changes to ventilation post-RT can be predicted. The differences between the predicted and actual outcome are similar to differences between repeat scans with equivalent ventilation. This work was supported by NIH grant CA166703 and a Pilot Grant from University of Iowa Carver College of Medicine.« less

  20. SU-F-19A-05: Experimental and Monte Carlo Characterization of the 1 Cm CivaString 103Pd Brachytherapy Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J; Micka, J; Culberson, W

    Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this sourcemore » were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.« less

  1. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    NASA Technical Reports Server (NTRS)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  2. Thromboelastogram-guided enoxaparin dosing does not confer protection from deep venous thrombosis: a randomized controlled pilot trial.

    PubMed

    Louis, Scott G; Van, Philbert Y; Riha, Gordon M; Barton, Jeffrey S; Kunio, Nicholas R; Underwood, Samantha J; Differding, Jerome A; Rick, Elizabeth; Ginzburg, Enrique; Schreiber, Martin A

    2014-04-01

    The incidence of deep venous thrombosis (DVT) remains high in general surgery and trauma patients despite widespread prophylaxis with enoxaparin. A recent study demonstrated decreased incidence of DVT if patients on enoxaparin had a change in R time (ΔR) of greater than 1 minute when heparinase-activated thromboelastography (TEG) was compared with normal TEG. We hypothesized that using ΔR-guided dosing would result in decreased DVT rates. A prospective, randomized controlled trial was performed at a Level 1 trauma center. Both trauma and general surgery patients were included. Upon enrollment, demographic data including age, sex, body mass index, and Acute Physiology and Chronic Health Evaluation II score were obtained. Enrolled patients were randomized to standard (30 mg twice a day) or TEG-guided dosing. Dose-adjusted patients underwent daily enoxaparin titration to achieve an ΔR of 1 minute to 2 minutes. Venous thromboembolism screening was performed per institutional protocol. Antithrombin III (AT-III) and anti-Xa levels were drawn at peak enoxaparin concentrations. A total of 87 patients were enrolled. There was no difference in demographic data between the groups. No pulmonary emboli were identified. The control group had a DVT rate of 16%, while the experimental group had a rate of 14% (p = nonsignificant). The experimental group's median enoxaparin dosage, 50 mg twice a day, was significantly higher than that of the control (p < 0.01). TEG ΔR was not different between the control and experimental groups. Beginning at Day 3, anti-Xa levels were higher in the experimental group (p < 0.05). There was no difference in AT-III activity between the two groups; 67% of the patients demonstrated AT-III deficiency. TEG adjusted enoxaparin dosing led to significant increases in anti-Xa activity, which did not correlate with a decreased DVT rate. Failure to reduce the DVT rate and increase ΔR despite increased dosing and increased anti-Xa activity is consistent with the high rate of AT-III deficiency detected in this study cohort. These data suggest that the future of DVT prevention may not lie in the optimization of low molecular weight heparin therapy but rather in compounds that increase antithrombin directly or operate independently of the AT-III pathway. Therapeutic study, level III.

  3. Contraction frequency after administration of misoprostol in obese versus nonobese women.

    PubMed

    Stefely, Erin; Warshak, Carri R

    2018-04-30

    To examine impact of obesity on contraction frequency following misoprostol. Our hypothesis is that an increased volume of distribution reduces the bioavailability of misoprostol and may be an explanation for reduced efficacy. We examined the contraction frequency as a surrogate marker for bioavailability of misoprostol. We compared the rate of contractions at five time intervals in 313 subjects: prior to administration, and at four intervals post administration. We compared number of contractions in obese versus nonobese. As a planned secondary analysis, we then compared the rate of change in contractions per hour at four time intervals: a repeated measures analysis to compare the rate of change in contractions per hour over the 5-hour window controlling for race (White versus non-White) and parity (primiparous versus multiparous). General linear model and repeated measures analysis were conducted to report the parameter estimates, least square means, difference of least square means, and p values. Nonobese women presented with more contractions at baseline, 7 ± 5 versus 4 ± 5 c/h, p < .001. At all four time intervals after misoprostol administration obese women had fewer contractions per hour. The rate of change in contraction frequency after administration found obese women had a lower rate of increase in contraction frequency over the course of all four hours. We found a least squares means estimate (c/h): first hour (-0.87), p = .08, second hour (-2.43), p = .01, third hour (-1.80), p = .96, and fourth hour (-2.98), p = .007. Obese women have a lower rate of contractions per hour at baseline and at four intervals after misoprostol administration. In addition, the rate of change in the increase in contractions/hour also was reduced in obese women versus nonobese women. This suggests a lower bioavailability of misoprostol in women with a larger volume of distribution which would likely impact the efficacy of misoprostol in obese women when given the same dose of misoprostol. It is unknown if higher misoprostol dosing would increase efficacy of misoprostol in obese women.

  4. Predictions of Leukemia Risks to Astronauts from Solar Particle Events

    NASA Technical Reports Server (NTRS)

    Cucinotta, F. A.; Atwell, W.; Kim, M. Y.; George, K. A.; Ponomarev, A.; Nikjoo, H.; Wilson, J. W.

    2006-01-01

    Leukemias consisting of acute and chronic myeloid leukemia and acute lymphatic lymphomas represent the earliest cancers that appear after radiation exposure, have a high lethality fraction, and make up a significant fraction of the overall fatal cancer risk from radiation for adults. Several considerations impact the recommendation of a preferred model for the estimation of leukemia risks from solar particle events (SPE's): The BEIR VII report recommends several changes to the method of calculation of leukemia risk compared to the methods recommended by the NCRP Report No. 132 including the preference of a mixture model with additive and multiplicative components in BEIR VII compared to the additive transfer model recommended by NCRP Report No. 132. Proton fluences and doses vary considerably across marrow regions because of the characteristic spectra of primary solar protons making the use of an average dose suspect. Previous estimates of bone marrow doses from SPE's have used an average body-shielding distribution for marrow based on the computerized anatomical man model (CAM). We have developed an 82-point body-shielding distribution that faithfully reproduces the mean and variance of SPE doses in the active marrow regions (head and neck, chest, abdomen, pelvis and thighs) allowing for more accurate estimation of linear- and quadratic-dose components of the marrow response. SPE's have differential dose-rates and a pseudo-quadratic dose response term is possible in the peak-flux period of an event. Also, the mechanistic basis for leukemia risk continues to improve allowing for improved strategies in choosing dose-rate modulation factors and radiation quality descriptors. We make comparisons of the various choices of the components in leukemia risk estimates in formulating our preferred model. A major finding is that leukemia could be the dominant risk to astronauts for a major solar particle event.

  5. Single dosing comparison of the relative cardiac beta 1/beta 2 activity of inhaled fenoterol and salbutamol in normal subjects.

    PubMed Central

    Newnham, D M; Wheeldon, N M; Lipworth, B J; McDevitt, D G

    1993-01-01

    BACKGROUND--The aim of the present study was to compare the dose related effects of fenoterol and salbutamol on cardiac beta 1 and beta 2 receptors using the beta 1 selective antagonist atenolol, in order to dissect out relative beta 1/beta 2 mediated responses. METHODS--Fourteen normal volunteers were randomised to receive pretreatment with either atenolol 25 mg or placebo, followed by inhaled fenoterol or salbutamol in equal doses by weight (cumulative doses of 1 mg and 4 mg). Measurements were made 30 minutes after inhaling each dose of beta 2 agonist. Values (mean and 95% CI) were expressed as a change from baseline. RESULTS--At 4 mg fenoterol produced equivalent falls in serum potassium and increases in tremor to salbutamol. The mean (95% CI) increase in heart rate (beats/min) with fenoterol at 4 mg after placebo was 47 (41-53) and after atenolol was 34 (28-40), with values for salbutamol being 46 (40-52) after placebo and 30 (24-36) after atenolol. The inotropic response (stroke distance) after atenolol at the 4 mg dose was 5.0 (3.9-6.1) cm for fenoterol and 4.7 (3.5-5.9) cm for salbutamol. There were no significant differences in heart rate or stroke distance response between the two drugs after either placebo or atenolol. Furthermore, ECG effects (Q-Tc and T wave) of fenoterol and salbutamol were comparable at both doses. CONCLUSIONS--These results show that there is no difference in the respective chronotropic or inotropic activities of fenoterol and salbutamol on cardiac beta 1 or beta 2 receptors when given at higher than conventional doses. PMID:8102213

  6. Effects of gamma irradiation dose-rate on sterile male Aedesaegypti

    NASA Astrophysics Data System (ADS)

    Ernawan, Beni; Tambunan, Usman Sumo Friend; Sugoro, Irawan; Sasmita, Hadian Iman

    2017-06-01

    Aedesaegypti is the most important vector for dengue, yellow fever and Zika viruses. Considering its medical importance, vector population control program utilizing radiation-based sterile insect technique (SIT) is one of the potential methods for preventing and limiting the dispersal of these viruses. The present study was undertaken to evaluate the dose-rates effects of γ-sterilization on quality parameters of sterile males. Males Ae.aegypti at the pupal stage were sterilized by applying 70 Gyγ-rays in varies dose-rates, i.e. 0 (control), 300, 600, 900, 1200 and 1500Gy/h utilizing panoramic irradiator. Adult males that emerged from the pupal stage were assessed for their quality parameters, which are the percentage of emergence, longevity, sterility and mating competitiveness. The results herein indicate that there was no major effect of dose-rate on the percentage of emergence, the data showedthat there were no differences between irradiated males compared with control. Generally, the longevity of irradiated males was lower compared to control. The data also demonstrated that longevity was significantly increased at the dose-rate from 300 to 900Gy/h, then decreased at the dose-rate 900 to 1500 Gy/h. Sterility of irradiated maleswas significantly different compared to control, while there was no significantly different at dose rate 300 to 1500 Gy/h. Mating competitiveness of irradiated males was increased at the dose rate from 300 to 1200 Gy/h, then the value was decreased significantly at the dose rate 1500 Gy/h. The dose-rate effects of γ-sterilization were discussed in the context genetic vector control, in particular, the SIT. The results give information and contribute to better understanding towards γ-sterilization optimization and quality parameters of sterile male Ae. aegypti on SIT methods.

  7. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.

    PubMed

    Karsch, L; Beyreuther, E; Burris-Mog, T; Kraft, S; Richter, C; Zeil, K; Pawelke, J

    2012-05-01

    The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10(11) Gy∕s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. The dosimeters are dose rate independent up to 4●10(9) Gy∕s within 2% (OSL and TLD) and up to 15●10(9) Gy∕s within 5% (EBT films). The diamond detectors show strong dose rate dependence. TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  8. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the numbermore » of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.« less

  9. Maximum dose rate is a determinant of hypothyroidism after 131I therapy of Graves' disease but the total thyroid absorbed dose is not.

    PubMed

    Krohn, Thomas; Hänscheid, Heribert; Müller, Berthold; Behrendt, Florian F; Heinzel, Alexander; Mottaghy, Felix M; Verburg, Frederik A

    2014-11-01

    The determinants of successful (131)I therapy of Graves' disease (GD) are unclear. To relate dosimetry parameters to outcome of therapy to identify significant determinants eu- and/or hypothyroidism after (131)I therapy in patients with GD. A retrospective study in which 206 Patients with GD treated in University Hospital between November 1999 and January 2011. All received (131)I therapy aiming at a total absorbed dose to the thyroid of 250 Gy based on pre-therapeutic dosimetry. Post-therapy dosimetric thyroid measurements were performed twice daily until discharge. From these measurements, thyroid (131)I half-life, the total thyroid absorbed dose, and the maximum dose rate after (131)I administration were calculated. In all, 48.5% of patients were hypothyroid and 28.6% of patients were euthyroid after (131)I therapy. In univariate analysis, nonhyperthyroid and hyperthyroid patients only differed by sex. A lower thyroid mass, a higher activity per gram thyroid tissue, a shorter effective thyroidal (131)I half-life, and a higher maximum dose rate, but not the total thyroid absorbed dose, were significantly associated with hypothyroidism. In multivariate analysis, the maximum dose rate remained the only significant determinant of hypothyroidism (P < .001). Maximum dose rates of 2.2 Gy/h and higher were associated with a 100% hypothyroidism rate. Not the total thyroid absorbed dose, but the maximum dose rate is a determinant of successfully achieving hypothyroidism in Graves' disease. Dosimetric concepts aiming at a specific total thyroid absorbed dose will therefore require reconsideration if our data are confirmed prospectively.

  10. SU-E-T-268: Differences in Treatment Plan Quality and Delivery Between Two Commercial Treatment Planning Systems for Volumetric Arc-Based Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, S; Zhang, H; Zhang, B

    2015-06-15

    Purpose: To clinically evaluate the differences in volumetric modulated arc therapy (VMAT) treatment plan and delivery between two commercial treatment planning systems. Methods: Two commercial VMAT treatment planning systems with different VMAT optimization algorithms and delivery approaches were evaluated. This study included 16 clinical VMAT plans performed with the first system: 2 spine, 4 head and neck (HN), 2 brain, 4 pancreas, and 4 pelvis plans. These 16 plans were then re-optimized with the same number of arcs using the second treatment planning system. Planning goals were invariant between the two systems. Gantry speed, dose rate modulation, MLC modulation, planmore » quality, number of monitor units (MUs), VMAT quality assurance (QA) results, and treatment delivery time were compared between the 2 systems. VMAT QA results were performed using Mapcheck2 and analyzed with gamma analysis (3mm/3% and 2mm/2%). Results: Similar plan quality was achieved with each VMAT optimization algorithm, and the difference in delivery time was minimal. Algorithm 1 achieved planning goals by highly modulating the MLC (total distance traveled by leaves (TL) = 193 cm average over control points per plan), while maintaining a relatively constant dose rate (dose-rate change <100 MU/min). Algorithm 2 involved less MLC modulation (TL = 143 cm per plan), but greater dose-rate modulation (range = 0-600 MU/min). The average number of MUs was 20% less for algorithm 2 (ratio of MUs for algorithms 2 and 1 ranged from 0.5-1). VMAT QA results were similar for all disease sites except HN plans. For HN plans, the average gamma passing rates were 88.5% (2mm/2%) and 96.9% (3mm/3%) for algorithm 1 and 97.9% (2mm/2%) and 99.6% (3mm/3%) for algorithm 2. Conclusion: Both VMAT optimization algorithms achieved comparable plan quality; however, fewer MUs were needed and QA results were more robust for Algorithm 2, which more highly modulated dose rate.« less

  11. Piezoelectric wafer active sensors under gamma radiation exposure toward applications for structural health monitoring of nuclear dry cask storage systems

    NASA Astrophysics Data System (ADS)

    Faisal Haider, Mohammad; Mei, Hanfei; Lin, Bin; Yu, Lingyu; Giurgiutiu, Victor; Lam, Poh-Sang; Verst, Christopher

    2018-03-01

    Structural health monitoring (SHM) is in urgent need and must be integrated into the nuclear-spent fuel storage systems to guarantee the safe operation. The dry cask storage system (DCSS) is such storage facility, which is licensed for temporary storage for nuclear-spent fuel at the independent spent fuel storage installations (ISFSIs) for certain predetermined period of time. Gamma radiation is one of the major radiation sources near DCSS. Therefore, a detailed experimental investigation was completed on the gamma radiation endurance of piezoelectric wafer active sensors (PWAS) transducers for SHM applications to the DCSS system. The irradiation test was done in a Co-60 gamma irradiator. Lead Zirconate Titanate (PZT) and Gallium Orthophosphate (GaPO4) PWAS transducers were exposed to 40.7 kGy gamma radiation. Total radiation dose was achieved in two different radiation dose rates: (a) slower radiation rate at 0.1 kGy/hr for 20 hours (b) accelerated radiation rate at 1.233 kGy/hr for 32 hours. The total cumulative radiation dose of 40.7 kGy is equivalent to 45 years of operation in DCSS system. Electro-mechanical impedance and admittance (EMIA) signatures and electrical capacitance were measured to evaluate the PWAS performance after each gamma radiation exposure. The change in resonance frequency of PZT-PWAS transducer for both in-plane and thickness mode was observed. The GaPO4-PWAS EMIA spectra do not show a significant shift in resonance frequency after gamma irradiation exposure. Radiation endurance of new high-temperature HPZ-HiT PWAS transducer was also evaluated. The HPZ-HiT transducers were exposed to gamma radiation at 1.233 kGy/hr for 160 hours with 80 hours interval. Therefore, the total accumulated gamma radiation dose is 184 kGy. No significant change in impedance spectra was observed due to gamma radiation exposure.

  12. Integrated survey on toxic effects of lindane on neotropical fish: Corydoras paleatus and Jenynsia multidentata.

    PubMed

    Pesce, Silvia F; Cazenave, Jimena; Monferrán, Magdalena V; Frede, Silvia; Wunderlin, Daniel A

    2008-12-01

    We report the effect of lindane on fish experimentally exposed to lindane. Sublethal toxicity was assessed through (a) changes in histopathology; (b) the activity of GST in different organs; and (c) bioaccumulation in exposed fish. We present a survey on toxic effects of lindane at these three levels, proposing a sequence of dose-dependent effects. Physiological damage was reversible at lowest doses, but severe at the highest, including damage consistent with fibrosis in liver and karyolitic nucleus in brain of both studied species. Exposure of Jenynsia multidentata above 6 microg L(-1) caused activation a GST in liver and gills, followed by inhibition at 75 microg L(-1). Interestingly, the bioaccumulation rate was suddenly increased when GST was inhibited. Corydoras paleatus exposed to 6.0 microg L(-1) lindane did not present significant changes in GST activity; however, enzymatic inhibition was observed above 25 microg L(-1). The bioaccumulation rate in C. paleatus remained constant throughout the experiments. All in all, these results evidence that C. paleatus is more sensitive to lindane than J. multidentata.

  13. Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio

    2008-11-01

    Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined beforemore » and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT.« less

  14. A Randomized Trial of the Effects of Nebulized Albuterol on Pulmonary Edema in Brain Dead Organ Donors

    PubMed Central

    Ware, Lorraine B.; Landeck, Megan; Koyama, Tatsuki; Zhao, Zhiguo; Singer, Jonathan; Kern, Ryan; Neidlinger, Nikole; Nguyen, John; Johnson, Elizabeth; Janz, David R.; Bernard, Gordon R.; Lee, Jae W.; Matthay, Michael A.

    2013-01-01

    Donor lung utilization rates are persistently low primarily due to donor lung dysfunction. We hypothesized that a treatment that enhances the resolution of pulmonary edema by stimulating the rate of alveolar fluid clearance would improve donor oxygenation and increase donor lung utilization. We conducted a randomized, blinded, placebo-controlled trial of aerosolized albuterol (5 mg q4h) versus saline placebo during active donor management in 506 organ donors. The primary outcome was change in oxygenation (PaO2/FiO2) from enrollment to organ procurement. The albuterol (n=260) and placebo (n=246) groups were well matched for age, gender, ethnicity, smoking, and cause of brain death. The change in PaO2/FiO2 from enrollment to organ procurement did not differ between treatment groups (p=0.54) nor did donor lung utilization (albuterol 29% vs. placebo 32%, p=0.44). Donors in the albuterol vs. placebo group were more likely to have the study drug dose reduced (13% vs. 1%, p<0.001) or stopped (8% vs. 0%, p<0.001) for tachycardia. In summary, treatment with high dose inhaled albuterol during the donor management period did not improve donor oxygenation or increase donor lung utilization but did cause tachycardia. High dose aerosolized albuterol should not be used in donors to enhance the resolution of pulmonary edema. PMID:24730050

  15. The Optimal Dose of Nicardipine for Enhancement of Indirect Portography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Yutaka; Nakamura, Hironobu; Akaji, Hideyo

    1998-01-15

    Purpose: To determine the optimal dose of nicardipine (NCR) for enhancement of indirect portography. Methods: Forty-eight patients underwent conventional film indirect portography via the superior mesenteric artery (SMA) first without and then with preinjection of 1/64-2 mg of NCR into the SMA. Results: NCR (1/8-2 mg) shortened the arterial phase to 50% and the portal appearance time to 60% of control without reflux of contrast medium into the aorta. Portal enhancement was excellent at doses of 1/32 mg or more. Blood pressures and pulse rate showed no significant change at 1/4 mg or less. Conclusion: NCR (1/8-1/4 mg) into themore » SMA is the optimal dose for achieving sufficient contrast enhancement on indirect portography while reducing the transit time of contrast medium and minimizing effects on the systemic circulation.« less

  16. A phase 2a randomized, parallel group, dose-ranging study of molindone in children with attention-deficit/hyperactivity disorder and persistent, serious conduct problems.

    PubMed

    Stocks, Jennifer Dugan; Taneja, Baldeo K; Baroldi, Paolo; Findling, Robert L

    2012-04-01

    To evaluate safety and tolerability of four doses of immediate-release molindone hydrochloride in children with attention-deficit/hyperactivity disorder (ADHD) and serious conduct problems. This open-label, parallel-group, dose-ranging, multicenter trial randomized children, aged 6-12 years, with ADHD and persistent, serious conduct problems to receive oral molindone thrice daily for 9-12 weeks in four treatment groups: Group 1-10 mg (5 mg if weight <30 kg), group 2-20 mg (10 mg if <30 kg), group 3-30 mg (15 mg if <30 kg), and group 4-40 mg (20 mg if <30 kg). The primary outcome measure was to evaluate safety and tolerability of molindone in children with ADHD and serious conduct problems. Secondary outcome measures included change in Nisonger Child Behavior Rating Form-Typical Intelligence Quotient (NCBRF-TIQ) Conduct Problem subscale scores, change in Clinical Global Impressions-Severity (CGI-S) and -Improvement (CGI-I) subscale scores from baseline to end point, and Swanson, Nolan, and Pelham rating scale-revised (SNAP-IV) ADHD-related subscale scores. The study randomized 78 children; 55 completed the study. Treatment with molindone was generally well tolerated, with no clinically meaningful changes in laboratory or physical examination findings. The most common treatment-related adverse events (AEs) included somnolence (n=9), weight increase (n=8), akathisia (n=4), sedation (n=4), and abdominal pain (n=4). Mean weight increased by 0.54 kg, and mean body mass index by 0.24 kg/m(2). The incidence of AEs and treatment-related AEs increased with increasing dose. NCBRF-TIQ subscale scores improved in all four treatment groups, with 34%, 34%, 32%, and 55% decreases from baseline in groups 1, 2, 3, and 4, respectively. CGI-S and SNAP-IV scores improved over time in all treatment groups, and CGI-I scores improved to the greatest degree in group 4. Molindone at doses of 5-20 mg/day (children weighing <30 kg) and 20-40 mg (≥ 30 kg) was well tolerated, and preliminary efficacy results suggest that molindone produces dose-related behavioral improvements over 9-12 weeks. Additional double-blind, placebo-controlled trials are needed to further investigate molindone in this pediatric population.

  17. Assessment of dose rate to terrestrial biota in the area around coal fired power plant applying ERICA tool and RESRAD BIOTA code.

    PubMed

    Ćujić, Mirjana; Dragović, Snežana

    2018-08-01

    This paper presents the environmental radiation risk assessment based on two software program approaches ERICA Tool (version 1.2) and RESRAD BIOTA (version 1.5) to estimate dose rates to terrestrial biota in the area around the largest coal fired power plant in Serbia. For dose rate assessment software's default reference animals and plants and the best estimated values of activity concentrations of 238 U, 234 U, 234 Th, 232 Th, 230 Th, 226 Ra, 210 Pb, 210 Po, 137 Cs in soil were used. Both approaches revealed the highest contribution to the internal dose rate due to 226 Ra and 210 Po, while 137 Cs contributed the most to the external dose rate. In the investigated area total dose rate to biota derived using ERICA Tool ranged from 0.3 to 14.4 μGy h -1 . The natural radionuclides exhibited significantly higher contribution to the total dose rate than the artificial one. In the investigated area, only dose rate for lichens and bryophytes exceeded ERICA Tool screening value of total dose rate of 10 μGy h -1 suggested as confident that environmental risks are negligible. The assessed total dose rates for reference animals and plants using RESRAD BIOTA were found to be 7 and 3 μGy h -1 , respectively. In RESRAD BIOTA - Level 3, 10 species (Lumbricus terrestris, Rana lessonae, Sciurus vulgaris, Anas platyrhynchos, Lepus europaeus, Vulpes vulpes, Capreolus capreolus, Suss crofa, Quercu srobur, Tilia spp.) representative for the study area were modeled. Among them the highest total dose rate (4.5 μGy h -1 ) was obtained for large mammals. Differences in the predicted dose rates to biota using the two software programs are the consequence of the difference in the values of transfer parameters used to calculate activity concentrations in biota. Doses of ionizing radiation estimated in this study will not exhibit deterministic effects at the population level. Thus, the obtained results indicate no significant radiation impact of coal fired power plant operation on terrestrial biota. This paper confirms the use ERICA Tool and RESRAD BIOTA softwares as flexible and effective means of radiation impact assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Radiation protocols determine acute graft-versus-host disease incidence after allogeneic bone marrow transplantation in murine models.

    PubMed

    Schwarte, Sebastian; Bremer, Michael; Fruehauf, Joerg; Sorge, Yanina; Skubich, Susanne; Hoffmann, Matthias W

    2007-09-01

    Effects of radiation sources used for total body irradiation (TBI) on Graft-versus-Host Disease (GvHD) induction were examined. In a T cell receptor (TCR) transgenic mouse model, single fraction TBI was performed with different radiation devices ((60)Cobalt; (137)Cesium; 6 MV linear accelerator), dose rates (0.85; 1.5; 2.9; 5 Gy/min) and total doses before allogeneic bone marrow transplantation (BMT). Recipients were observed for 120 days. Different tissues were examined histologically. Acute GvHD was induced by a dose rate of 0.85 Gy/min ((60)Cobalt) and a total dose of 9 Gy and injection of 5 x 10(5) lymph node cells plus 5 x 10(6) bone marrow cells. Similar results were obtained using 6 MV linear accelerator- (linac-) photons with a dose rate of 1.5 Gy/min and 0.85 Gy/min, a total dose of 9.5 Gy and injection of same cell numbers. TBI with (137)Cesium (dose rate: 2.5 Gy/min) did not lead reproducibly to lethal acute GvHD. Experimental TBI in murine models may induce different immunological responses, depending on total energy, total single dose and dose rate. GvHD might also be induced by TBI with low dose rates.

  19. Different dose rate-dependent responses of human melanoma cells and fibroblasts to low dose fast neutrons.

    PubMed

    Dionet, Claude; Müller-Barthélémy, Melanie; Marceau, Geoffroy; Denis, Jean-Marc; Averbeck, Dietrich; Gueulette, John; Sapin, Vincent; Pereira, Bruno; Tchirkov, Andrei; Chautard, Emmanuel; Verrelle, Pierre

    2016-09-01

    To analyze the dose rate influence in hyper-radiosensitivity (HRS) of human melanoma cells to very low doses of fast neutrons and to compare to the behaviour of normal human skin fibroblasts. We explored different neutron dose rates as well as possible implication of DNA double-strand breaks (DSB), apoptosis, and energy-provider adenosine-triphosphate (ATP) levels during HRS. HRS in melanoma cells appears only at a very low dose rate (VLDR), while a high dose rate (HDR) induces an initial cell-radioresistance (ICRR). HRS does not seem to be due either to DSB or to apoptosis. Both phenomena (HRS and ICRR) appear to be related to ATP availability for triggering cell repair. Fibroblast survival after neutron irradiation is also dose rate-dependent but without HRS. Melanoma cells or fibroblasts exert their own survival behaviour at very low doses of neutrons, suggesting that in some cases there is a differential between cancer and normal cells radiation responses. Only the survival of fibroblasts at HDR fits the linear no-threshold model. This new insight into human cell responses to very low doses of neutrons, concerns natural radiations, surroundings of accelerators, proton-therapy devices, flights at high altitude. Furthermore, ATP inhibitors could increase HRS during high-linear energy transfer (high-LET) irradiation.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Zhang, W; Lu, J

    Purpose: To investigate the accuracy and feasibility of dose calculations using kilovoltage cone beam computed tomography in cervical cancer radiotherapy using a correction algorithm. Methods: The Hounsfield units (HU) and electron density (HU-density) curve was obtained for both planning CT (pCT) and kilovoltage cone beam CT (CBCT) using a CIRS-062 calibration phantom. The pCT and kV-CBCT images have different HU values, and if the HU-density curve of CBCT was directly used to calculate dose in CBCT images may have a deviation on dose distribution. It is necessary to normalize the different HU values between pCT and CBCT. A HU correctionmore » algorithm was used for CBCT images (cCBCT). Fifteen intensity-modulated radiation therapy (IMRT) plans of cervical cancer were chosen, and the plans were transferred to the pCT and cCBCT data sets without any changes for dose calculations. Phantom and patient studies were carried out. The dose differences and dose distributions were compared between cCBCT plan and pCT plan. Results: The HU number of CBCT was measured by several times, and the maximum change was less than 2%. To compare with pCT, the CBCT and cCBCT has a discrepancy, the dose differences in CBCT and cCBCT images were 2.48%±0.65% (range: 1.3%∼3.8%) and 0.48%±0.21% (range: 0.1%∼0.82%) for phantom study, respectively. For dose calculation in patient images, the dose differences were 2.25%±0.43% (range: 1.4%∼3.4%) and 0.63%±0.35% (range: 0.13%∼0.97%), respectively. And for the dose distributions, the passing rate of cCBCT was higher than the CBCTs. Conclusion: The CBCT image for dose calculation is feasible in cervical cancer radiotherapy, and the correction algorithm offers acceptable accuracy. It will become a useful tool for adaptive radiation therapy.« less

Top