van der Stouwe, A M M; Elting, J W; van der Hoeven, J H; van Laar, T; Leenders, K L; Maurits, N M; Tijssen, M A J
2016-09-01
Distinguishing between different tremor disorders can be challenging. Some tremor disorders are thought to have typical tremor characteristics: the current study aims to provide sensitivity and specificity for five 'typical' tremor phenomena. Retrospectively, we examined 210 tremor patients referred for electrophysiological recordings between January 2008 and January 2014. The final clinical diagnosis was used as the gold standard. The first step was to determine whether patients met neurophysiological criteria for their type of tremor. Once established, we focused on 'typical' characteristics: tremor frequency decrease upon loading (enhanced physiological tremor (EPT)), amplitude increase upon loading, distractibility and entrainment (functional tremor (FT)), and intention tremor (essential tremor (ET)). The prevalence of these phenomena in the 'typical' group was compared to the whole group. Most patients (87%) concurred with all core clinical neurophysiological criteria for their tremor type. We found a frequency decrease upon loading to be a specific (95%), but not a sensitive (42%) test for EPT. Distractibility and entrainment both scored high on sensitivity (92%, 91%) and specificity (94%, 91%) in FT, whereas a tremor amplitude increase was specific (92%), but not sensitive (22%). Intention tremor was a specific finding in ET (85%), but not a sensitive test (45%). Combination of characteristics improved sensitivity. In this study, we retrospectively determined sensitivity and specificity for five 'typical' tremor characteristics. Characteristics proved specific, but few were sensitive. These data on tremor phenomenology will help practicing neurologists to improve distinction between different tremor disorders. Copyright © 2016 Elsevier Ltd. All rights reserved.
Song, Yong Sub; Kim, Ji-Hoon; Na, Dong Gyu; Min, Hye Sook; Won, Jae-Kyung; Yun, Tae Jin; Choi, Seung Hong; Sohn, Chul-Ho
2016-08-01
We evaluate the gray-scale ultrasonographic characteristics that differentiate between nodular hyperplasia (NH) and neoplastic follicular-patterned lesions (NFPLs) of the thyroid gland. Ultrasonographic features of 750 patients with 832 thyroid nodules (NH, n = 361; or NFPLs, follicular adenoma, n = 123; follicular carcinoma, n = 159; and follicular variant papillary carcinoma, n = 189) were analyzed. Except for echogenicity, over two-thirds of the cases of NH and NFPLs share the ultrasonographic characteristics of solid internal content, a well-defined smooth margin and round-to-ovoid shape. Independent predictors for NH were non-solid internal content (sensitivity 27.1%, specificity 90.2%), isoechogenicity (sensitivity 69.5%, specificity 63.5%) and an ill-defined margin (sensitivity 18.8%, specificity 94.5%). Independent predictors for NFPLs were hypoechogenicity (sensitivity 60.5%, specificity 70.4%), marked hypoechogenicity (sensitivity 2.8%, specificity 99.4%) and taller-than-wide shape (sensitivity 6.6%, specificity 98.1%). Although NH and NFPLs commonly share ultrasonographic characteristics, non-solid internal content and ill-defined margin are specific to NH and marked hypoechogenicity and taller-than-wide shape are specific to NFPLs. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Allergen Sensitization Pattern by Sex: A Cluster Analysis in Korea.
Ohn, Jungyoon; Paik, Seung Hwan; Doh, Eun Jin; Park, Hyun-Sun; Yoon, Hyun-Sun; Cho, Soyun
2017-12-01
Allergens tend to sensitize simultaneously. Etiology of this phenomenon has been suggested to be allergen cross-reactivity or concurrent exposure. However, little is known about specific allergen sensitization patterns. To investigate the allergen sensitization characteristics according to gender. Multiple allergen simultaneous test (MAST) is widely used as a screening tool for detecting allergen sensitization in dermatologic clinics. We retrospectively reviewed the medical records of patients with MAST results between 2008 and 2014 in our Department of Dermatology. A cluster analysis was performed to elucidate the allergen-specific immunoglobulin (Ig)E cluster pattern. The results of MAST (39 allergen-specific IgEs) from 4,360 cases were analyzed. By cluster analysis, 39items were grouped into 8 clusters. Each cluster had characteristic features. When compared with female, the male group tended to be sensitized more frequently to all tested allergens, except for fungus allergens cluster. The cluster and comparative analysis results demonstrate that the allergen sensitization is clustered, manifesting allergen similarity or co-exposure. Only the fungus cluster allergens tend to sensitize female group more frequently than male group.
Carlsten, Chris; Dimich-Ward, Helen; Ferguson, Alexander; Becker, Allan; Dybuncio, Anne; Chan-Yeung, Moira
2011-02-01
The operating characteristics of PC(20) values used as cut-offs to define airway hyperresponsiveness, as it informs the diagnosis of asthma in children, are poorly understood. We examine data from a unique cohort to inform this concern. Determine the sensitivity and specificity of incremental PC(20) cut-offs for allergist-diagnosed asthma. Airway reactivity at age 7 was assessed in children within a birth cohort at high risk for asthma; PC(20) for methacholine was determined by standard technique including interpolation. The diagnosis of asthma was considered by the pediatric allergist without knowledge of the methacholine challenge results. Sensitivity and specificity were calculated using a cross-tabulation of asthma diagnosis with incremental PC(20) cut-off values, from 1.0 to 8.0 mg/ml, and plotted as receiver operator characteristic (ROC) curves. The "optimal" cut-off was defined as that PC(20) conferring maximal value for sensitivity plus specificity while the "balanced" cut-off was defined as that PC(20) at which sensitivity and specificity were most equal. 70/348 children (20.1%) were diagnosed with asthma. The optimal and balanced PC(20) cut-offs, both for all children and for females alone, were respectively 3 mg/ml (sensitivity 80.0%, specificity 49.1%) and 2 mg/ml (sensitivity 63.1%, specificity 64.7%). For males alone, the "optimal" and "balanced" PC(20) cut-offs were both 2 mg/ml. For this cohort of 7-year olds at high risk for asthma, methacholine challenge testing using a cut-off value of PC(20) 3 mg/ml conferred the maximal sum of specificity plus sensitivity. For contexts in which higher sensitivity or specificity is desired, other cut-offs may be preferred. Copyright © 2011 Wiley-Liss, Inc.
Loewenstein, Anat; Ferencz, Joseph R; Lang, Yaron; Yeshurun, Itamar; Pollack, Ayala; Siegal, Ruth; Lifshitz, Tova; Karp, Joseph; Roth, Daniel; Bronner, Guri; Brown, Justin; Mansour, Sam; Friedman, Scott; Michels, Mark; Johnston, Richards; Rapp, Moshe; Havilio, Moshe; Rafaeli, Omer; Manor, Yair
2010-01-01
The primary purpose of this study was to evaluate the ability of a home device preferential hyperacuity perimeter to discriminate between patients with choroidal neovascularization (CNV) and intermediate age-related macular degeneration (AMD), and the secondary purpose was to investigate the dependence of sensitivity on lesion characteristics. All participants were tested with the home device in an unsupervised mode. The first part of this work was retrospective using tests performed by patients with intermediate AMD and newly diagnosed CNV. In the second part, the classifier was prospectively challenged with tests performed by patients with intermediate AMD and newly diagnosed CNV. The dependence of sensitivity on lesion characteristics was estimated with tests performed by patients with CNV of both parts. In 66 eyes with CNV and 65 eyes with intermediate AMD, both sensitivity and specificity were 0.85. In the retrospective part (34 CNV and 43 intermediate AMD), sensitivity and specificity were 0.85 +/- 0.12 (95% confidence interval) and 0.84 +/- 0.11 (95% confidence interval), respectively. In the prospective part (32 CNV and 22 intermediate AMD), sensitivity and specificity were 0.84 +/- 0.13 (95% confidence interval) and 0.86 +/- 0.14 (95% confidence interval), respectively. Chi-square analysis showed no dependence of sensitivity on type (P = 0.44), location (P = 0.243), or size (P = 0.73) of the CNV lesions. A home device preferential hyperacuity perimeter has good sensitivity and specificity in discriminating between patients with newly diagnosed CNV and intermediate AMD. Sensitivity is not dependent on lesion characteristics.
Screening markers for chronic atrophic gastritis in Chiapas, Mexico.
Ley, C; Mohar, A; Guarner, J; Herrera-Goepfert, R; Figueroa, L S; Halperin, D; Parsonnet, J
2001-02-01
Intestinal-type gastric adenocarcinomas usually are preceded by chronic atrophic gastritis. Studies of gastric cancer prevention often rely on identification of this condition. In a clinical trial, we sought to determine the best serological screening method for chronic atrophic gastritis and compared our findings to the published literature. Test characteristics of potential screening tests (antibodies to Helicobacter pyloni or CagA, elevated gastrin, low pepsinogen, increased age) alone or in combination were examined among consecutive subjects enrolled in a study of H. pylori and preneoplastic gastric lesions in Chiapas, Mexico; 70% had chronic atrophic gastritis. English-language articles concerning screening for chronic atrophic gastritis were also reviewed. Sensitivity for chronic atrophic gastritis was highest for antibodies to H. pylori (92%) or CagA, or gastrin levels >25 ng/l (both 83%). Specificity, however, was low for these tests (18, 41, and 22%, respectively). Pepsinogen levels were highly specific but insensitive markers of chronic atrophic gastritis (for pepsinogen I <25 microg/l, sensitivity was 6% and specificity was 100%; for pepsinogen I:pepsinogen II ratio <2.5, sensitivity was 14% and specificity was 96%). Combinations of markers did not improve test characteristics. Screening test characteristics from the literature varied widely and did not consistently identify a good screening strategy. In this study, CagA antibodies alone had the best combination of test characteristics for chronic atrophic gastritis screening. However, no screening test was both highly sensitive and highly specific for chronic atrophic gastritis.
Youland, Ryan S; Pafundi, Deanna H; Brinkmann, Debra H; Lowe, Val J; Morris, Jonathan M; Kemp, Bradley J; Hunt, Christopher H; Giannini, Caterina; Parney, Ian F; Laack, Nadia N
2018-05-01
Treatment-related changes can be difficult to differentiate from progressive glioma using MRI with contrast (CE). The purpose of this study is to compare the sensitivity and specificity of 18F-DOPA-PET and MRI in patients with recurrent glioma. Thirteen patients with MRI findings suspicious for recurrent glioma were prospectively enrolled and underwent 18F-DOPA-PET and MRI for neurosurgical planning. Stereotactic biopsies were obtained from regions of concordant and discordant PET and MRI CE, all within regions of T2/FLAIR signal hyperintensity. The sensitivity and specificity of 18F-DOPA-PET and CE were calculated based on histopathologic analysis. Receiver operating characteristic curve analysis revealed optimal tumor to normal (T/N) and SUVmax thresholds. In the 37 specimens obtained, 51% exhibited MRI contrast enhancement (M+) and 78% demonstrated 18F-DOPA-PET avidity (P+). Imaging characteristics included M-P- in 16%, M-P+ in 32%, M+P+ in 46% and M+P- in 5%. Histopathologic review of biopsies revealed grade II components in 16%, grade III in 43%, grade IV in 30% and no tumor in 11%. MRI CE sensitivity for recurrent tumor was 52% and specificity was 50%. PET sensitivity for tumor was 82% and specificity was 50%. A T/N threshold > 2.0 altered sensitivity to 76% and specificity to 100% and SUVmax > 1.36 improved sensitivity and specificity to 94 and 75%, respectively. 18F-DOPA-PET can provide increased sensitivity and specificity compared with MRI CE for visualizing the spatial distribution of recurrent gliomas. Future studies will incorporate 18F-DOPA-PET into re-irradiation target volume delineation for RT planning.
Zhao, Huifang; Heard, Stephen O; Mullen, Marie T; Crawford, Sybil; Goldberg, Robert J; Frendl, Gyorgy; Lilly, Craig M
2012-06-01
Limited research has been conducted to compare the test characteristics of the 1991 and 2001 sepsis consensus definitions. This study assessed the accuracy of the two sepsis consensus definitions among adult critically ill patients compared to sepsis case adjudication by three senior clinicians. Observational study of patients admitted to intensive care units. Seven intensive care units of an academic medical center. A random sample of 960 patients from all adult intensive care unit patients between October 2007 and December 2008. None. Sensitivity, specificity, and the area under the receiver operating characteristic curve for the two consensus definitions were calculated by comparing the number of patients who met or did not meet consensus definitions vs. the number of patients who were or were not diagnosed with sepsis by adjudication. The 1991 sepsis definition had a high sensitivity of 94.6%, but a low specificity of 61.0%. The 2001 sepsis definition had a slightly increased sensitivity but a decreased specificity, which were 96.9% and 58.3%, respectively. The areas under the receiver operating characteristic curve for the two definitions were not statistically different (0.778 and 0.776, respectively). The sensitivities and areas under the receiver operating characteristic curve of both definitions were lower at the 24-hr time window level than those of the intensive care unit stay level, though their specificities increased slightly. Fever, high white blood cell count or immature forms, low Glasgow coma score, edema, positive fluid balance, high cardiac index, low PaO2/FIO2 ratio, and high levels of creatinine and lactate were significantly associated with sepsis by both definitions and adjudication. Both the 1991 and the 2001 sepsis definition have a high sensitivity but low specificity; the 2001 definition has a slightly increased sensitivity but a decreased specificity compared to the 1991 definition. The diagnostic performances of both definitions were suboptimal. A parsimonious set of significant predictors for sepsis diagnosis is likely to improve current sepsis case definitions.
Herrero Babiloni, Alberto; Nixdorf, Donald R; Law, Alan S; Moana-Filho, Estephan J; Shueb, Sarah S; Nguyen, Ruby H; Durham, Justin
2017-01-01
To evaluate the accuracy of a questionnaire modified for the identification of intraoral pain with neuropathic characteristics in a clinical orofacial pain sample population. 136 participants with at least one of four orofacial pain diagnoses (temporomandibular disorders [TMD, n = 41], acute dental pain [ADP, n = 41], trigeminal neuralgia [TN, n = 19], persistent dentoalveolar pain disorder [PDAP, n = 14]) and a group of pain-free controls (n = 21) completed the modified S-LANSS, a previously adapted version of the original questionnaire devised to detected patients suffering from intraoral pain with neuropathic characteristics. Psychometric properties (sensitivity, specificity, positive predictive value [PPV], negative predictive value [NPV]) were calculated in two analyses with two different thresholds: (1) Detection of pain with neuropathic characteristics: PDAP + TN were considered positive, and TMD + ADP + controls were considered negative per gold standard (expert opinion). (2) Detection of PDAP: PDAP was considered positive and TMD + ADP were considered negative per gold standard. For both analyses, target values for adequate sensitivity and specificity were defined as ≥ 80%. For detection of orofacial pain with neuropathic characteristics (PDAP + TN), the modified S-LANSS presented with the most optimistic threshold sensitivity of 52% (95% confidence interval [CI], 34-69), specificity of 70% (95% CI, 60-79), PPV of 35% (95% CI, 22-51), and NPV of 82% (95% CI, 72-89). For detection of PDAP only, with the most optimistic threshold sensitivity was 64% (95% CI, 35-87), specificity 63% (95% CI, 52-74), PPV 23% (95% CI, 11-39) and NPV 91% (95% CI, 81-97). Based on a priori defined criteria, the modified S-LANSS did not show adequate accuracy to detect intraoral pain with neuropathic characteristics in a clinical orofacial pain sample.
International ring trial to detect anti-Trichinella IgG by ELISA on pig sera.
USDA-ARS?s Scientific Manuscript database
In the present study, the sensitivity and specificity of the ELISA assay determined by the CRLP validation was 100% and 98.29%, respectively. The assay was reproducible, moreover, based on the receiver-operator characteristic (ROC) curve, the sensitivity and specificity of the assay reached 97.5% an...
Diabetic retinopathy screening using deep neural network.
Ramachandran, Nishanthan; Hong, Sheng Chiong; Sime, Mary J; Wilson, Graham A
2017-09-07
There is a burgeoning interest in the use of deep neural network in diabetic retinal screening. To determine whether a deep neural network could satisfactorily detect diabetic retinopathy that requires referral to an ophthalmologist from a local diabetic retinal screening programme and an international database. Retrospective audit. Diabetic retinal photos from Otago database photographed during October 2016 (485 photos), and 1200 photos from Messidor international database. Receiver operating characteristic curve to illustrate the ability of a deep neural network to identify referable diabetic retinopathy (moderate or worse diabetic retinopathy or exudates within one disc diameter of the fovea). Area under the receiver operating characteristic curve, sensitivity and specificity. For detecting referable diabetic retinopathy, the deep neural network had an area under receiver operating characteristic curve of 0.901 (95% confidence interval 0.807-0.995), with 84.6% sensitivity and 79.7% specificity for Otago and 0.980 (95% confidence interval 0.973-0.986), with 96.0% sensitivity and 90.0% specificity for Messidor. This study has shown that a deep neural network can detect referable diabetic retinopathy with sensitivities and specificities close to or better than 80% from both an international and a domestic (New Zealand) database. We believe that deep neural networks can be integrated into community screening once they can successfully detect both diabetic retinopathy and diabetic macular oedema. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Cervical and Ocular VEMP Testing in Diagnosing Superior Semicircular Canal Dehiscence.
Hunter, Jacob B; Patel, Neil S; O'Connell, Brendan P; Carlson, Matthew L; Shepard, Neil T; McCaslin, Devin L; Wanna, George B
2017-05-01
Objective To determine the sensitivity and specificity of ocular and cervical vestibular evoked myogenic potentials (VEMPs) in the diagnosis of superior semicircular canal dehiscence (SCD) and to describe the VEMP response characteristics that are most sensitive to SCD and compare the findings to previous reports. Study Design Case series with chart review. Setting Two tertiary neurotologic referral centers. Subjects and Methods Cervical and ocular VEMP peak-to-peak amplitudes and thresholds from 39 adult patients older than 18 years with surgically confirmed SCD were compared with 84 age-matched controls. Results Using receiver operating characteristic (ROC) curves, cervical VEMP (cVEMP) amplitudes, cVEMP thresholds, and ocular VEMP (oVEMP) amplitudes had areas under the curve of 0.731, 0.912, and 0.856, respectively, all of which were statistically significant ( P < .0001). For cVEMP thresholds, at the clinical equivalent ≤85-dB normalized hearing level (nHL) threshold, the sensitivity and specificity were 97.3% and 31.3%, respectively. At the ≤70-dB nHL threshold, the sensitivity and specificity were 73.0% and 94.0%, respectively. For oVEMP amplitudes >12.0 µV, the sensitivity and specificity were 78.6% and 81.7%, respectively. Conclusion Data from this multicenter study suggest that both cVEMP thresholds and oVEMP amplitudes remain good diagnostic tests for identifying SCD, with each test dependent on a number of factors. The sensitivity and specificity of these individual tests may vary slightly between centers depending on testing parameters used.
Measures of accuracy and performance of diagnostic tests.
Drobatz, Kenneth J
2009-05-01
Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.
Garces, A; Jehan, I; Ditekemena, J; Phiri, M; Thorsten, V; Mazariegos, M; Chomba, E; Pasha, O; Tshefu, A; Wallace, D; McClure, EM; Goldenberg, RL; Carlo, WA; Wright, LL; Bose, C
2012-01-01
Abstract Objective To assess the feasibility of using birth attendants instead of bereaved mothers as perinatal verbal autopsy respondents. Methods Verbal autopsy interviews for early neonatal deaths and stillbirths were conducted separately among mothers (reference standard) and birth attendants in 38 communities in four developing countries. Concordance between maternal and attendant responses was calculated for all questions, for categories of questions and for individual questions. The sensitivity and specificity of individual questions with the birth attendant as respondent were assessed. Findings For early neonatal deaths, concordance across all questions was 94%. Concordance was at least 95% for more than half the questions on maternal medical history, birth attendance and neonate characteristics. Concordance on any given question was never less than 80%. Sensitivity and specificity varied across individual questions, more than 80% of which had a sensitivity of at least 80% and a specificity of at least 90%. For stillbirths, concordance across all questions was 93%. Concordance was 95% or greater more than half the time for questions on birth attendance, site of delivery and stillborn characteristics. Sensitivity and specificity varied across individual questions. Over 60% of the questions had a sensitivity of at least 80% and over 80% of them had a specificity of at least 90%. Overall, the causes of death established through verbal autopsy were similar, regardless of respondent. Conclusion Birth attendants can substitute for bereaved mothers as verbal autopsy respondents. The questions in existing harmonized verbal autopsy questionnaires need further refinement, as their sensitivity and specificity differ widely. PMID:22461715
Hamashima, Chisato; Sasazuki, Shizuka; Inoue, Manami; Tsugane, Shoichiro
2017-03-09
Chronic Helicobacter pylori infection plays a central role in the development of gastric cancer as shown by biological and epidemiological studies. The H. pylori antibody and serum pepsinogen (PG) tests have been anticipated to predict gastric cancer development. We determined the predictive sensitivity and specificity of gastric cancer development using these tests. Receiver operating characteristic analysis was performed, and areas under the curve were estimated. The predictive sensitivity and specificity of gastric cancer development were compared among single tests and combined methods using serum pepsinogen and H. pylori antibody tests. From a large-scale population-based cohort of over 100,000 subjects followed between 1990 and 2004, 497 gastric cancer subjects and 497 matched healthy controls were chosen. The predictive sensitivity and specificity were low in all single tests and combination methods. The highest predictive sensitivity and specificity were obtained for the serum PG I/II ratio. The optimal PG I/II cut-off values were 2.5 and 3.0. At a PG I/II cut-off value of 3.0, the sensitivity was 86.9% and the specificity was 39.8%. Even if three biomarkers were combined, the sensitivity was 97.2% and the specificity was 21.1% when the cut-off values were 3.0 for PG I/II, 70 ng/mL for PG I, and 10.0 U/mL for H. pylori antibody. The predictive accuracy of gastric cancer development was low with the serum pepsinogen and H. pylori antibody tests even if these tests were combined. To adopt these biomarkers for gastric cancer screening, a high specificity is required. When these tests are adopted for gastric cancer screening, they should be carefully interpreted with a clear understanding of their limitations.
Characteristics of Stuttering in Dutch-Speaking Individuals
ERIC Educational Resources Information Center
Boey, Ronny A.; Wuyts, Floris L.; van de Heyning, Paul H.; Heylen, Louis; de Bodt, Marc S.
2009-01-01
Clinical diagnostic procedures to distinguish stuttering from non-stuttering individuals partially rely on the observation of characteristics of stuttered words or syllables. The purpose of this study was to examine the sensitivity and specificity of such a procedure, and to describe the observed characteristics of stuttered words. Methods…
Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong
2017-01-01
We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P < 0.001) and 0.823 for PSAD (P < 0.001). PSA of 4.5 ng ml-1 had sensitivity of 94.4%, specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, P< 0.001) were significant predictors for prostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.
Jahan-Tigh, Richard R; Chinn, Garrett M; Rapini, Ronald P
2016-01-01
The incorporation of high-resolution cameras into smartphones has allowed for a variety of medical applications including the use of lens attachments that provide telescopic, macroscopic, and dermatoscopic data, but the feasibility and performance characteristics of such a platform for use in dermatopathology have not been described. To determine the diagnostic performance of a smartphone microscope compared to traditional light microscopy in dermatopathology specimens. A simple smartphone microscope constructed with a 3-mm ball lens was used to prospectively evaluate 1021 consecutive dermatopathology cases in a blinded fashion. Referred, consecutive specimens from the community were evaluated at a single university hospital. The performance characteristics of the smartphone platform were calculated by using conventional light microscopy as the gold standard. The sensitivity and specificity for the diagnosis of melanoma, nonmelanoma skin cancers, and other miscellaneous conditions by the phone microscopy platform, as compared with traditional light microscopy, were calculated. For basal cell carcinoma (n = 136), the sensitivity and specificity of smartphone microscopy were 95.6% and 98.1%, respectively. The sensitivity and specificity for squamous cell carcinoma (n = 94) were 89.4% and 97.3%, respectively. The lowest sensitivity was found in melanoma (n = 15) at 60%, although the specificity was high at 99.1%. The accuracy of diagnosis of inflammatory conditions and other neoplasms was variable. Mobile phone-based microscopy has excellent performance characteristics for the inexpensive diagnosis of nonmelanoma skin cancers in a setting where a traditional microscope is not available.
Cervical VEMP threshold response curve in the identification of Ménière's disease.
Zhu, Yi; McPherson, James; Beatty, Charles; Driscoll, Colin; Neff, Brian; Eggers, Scott; Shepard, Neil T
2014-03-01
To investigate the sensitivity/specificity of a shift upward in the most sensitive frequency of the cervical vestibular evoked myogenic potential (cVEMP) threshold-response curve in the identification of Ménière's disease (MD). A secondary purpose was to investigate the clinical characteristics that had an impact on the sensitivity/specificity and to adjust the criteria for a positive shift upward in the cVEMP curve to maximize performance of the test. A retrospective review of patients diagnosed with MD and those without MD. Two hundred ninety-four patients met the inclusion criteria of symptom complaints of spontaneous events of vertigo and a full vestibular and balance evaluation with cVEMP threshold-response curve testing. Two hundred six of these patients were diagnosed with MD, and 88 patients were determined to be non-MD. Review of the patients' medical records was used to extract data on the results of the cVEMP curve, age, gender, duration from time of onset of spontaneous events, pure tone average from hearing test, and water caloric asymmetry. Student's t-test, χ² test, receiver operating characteristic (ROC) curve with area under the curve (AUC), Pearson correlation coefficient, and sensitivity/specificity from 2 × 2 tables were all used in the analysis. Basic sensitivity/specificity for a shift upward in the most sensitive frequency to 1000 Hz in the cVEMP threshold-response curve was 0.47/0.64 respectively. Clinical characteristics that were found to have a significant impact on the sensitivity/specificity were age equal to or above 60 yr and a caloric asymmetry ≥25%. Various combinations of age and caloric with the requirement of a shift upward in the cVEMP curve most sensitive frequency to 1000 Hz resulted in significant but modest improvements in sensitivity/specificity. However, the overall performance was not shown acceptable for routine clinical use with maximum sensitivity at 0.73. Therefore, placing an emphasis on specificity over sensitivity results showed specificity of 0.95 for those under 60 yr and 0.90 for those 60 yr of age or older with sensitivity at 0.20, but only in the context of a ≥25% caloric asymmetry. We recommend the use of the shift upward to 1000 Hz with a caloric asymmetry as the clinical protocol to maximize the use of the cVEMP threshold-response curve for assistance in the identification of MD, in the context of a ≥25% caloric asymmetry. This implies that if the test is negative no interpretation of identification of MD can be made. If the test is positive the results can be used to increase the argument for MD since the probability of the result being a false positive is only 5-10%. American Academy of Audiology.
Moore, Abigail; Ashdown, Helen F; Shinkins, Bethany; Roberts, Nia W; Grant, Cameron C; Lasserson, Daniel S; Harnden, Anthony
2017-08-01
Pertussis (whooping cough) is a highly infective cause of cough that causes significant morbidity and mortality. Existing case definitions include paroxysmal cough, whooping, and posttussive vomiting, but diagnosis can be difficult. We determined the diagnostic accuracy of clinical characteristics of pertussis-associated cough. We systematically searched CINAHL, Embase, Medline, and SCI-EXPANDED/CPCI-S up to June 2016. Eligible studies compared clinical characteristics in those positive and negative for Bordetella pertussis infection, confirmed by laboratory investigations. Two authors independently completed screening, data extraction, and quality and bias assessments. For each characteristic, RevMan was used to produce descriptive forest plots. The bivariate meta-analysis method was used to generate pooled estimates of sensitivity and specificity. Of 1,969 identified papers, 53 were included. Forty-one clinical characteristics were assessed for diagnostic accuracy. In adult patients, paroxysmal cough and absence of fever have a high sensitivity (93.2% [CI, 83.2-97.4] and 81.8% [CI, 72.2-88.7], respectively) and low specificity (20.6% [CI, 14.7-28.1] and 18.8% [CI, 8.1-37.9]), whereas posttussive vomiting and whooping have low sensitivity (32.5% [CI, 24.5-41.6] and 29.8% [CI, 8.0-45.2]) and high specificity (77.7% [CI, 73.1-81.7] and 79.5% [CI, 69.4-86.9]). Posttussive vomiting in children is moderately sensitive (60.0% [CI, 40.3-77.0]) and specific (66.0% [CI, 52.5-77.3]). In adult patients, the presence of whooping or posttussive vomiting should rule in a possible diagnosis of pertussis, whereas the lack of a paroxysmal cough or the presence of fever should rule it out. In children, posttussive vomiting is much less helpful as a clinical diagnostic test. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Won, Huiloo; Abdul, Manaf Zahara; Mat Ludin, Arimi Fitri; Omar, Mohd Azahadi; Razali, Rosdinom; Shahar, Suzana
2017-01-01
Older adults are at risk of mild cognitive impairment (MCI), and simple anthropometric measurements can be used to screen for this condition. Thus, the aim of this study was to explore the cut-off values of body mass index (BMI) and waist circumference (WC) for predicting the risk of MCI in older Malaysian adults. A total of 2,240 Malaysian older adults aged ≥60 years were recruited using multistage random sampling in a population based cross-sectional study. Receiver operating characteristic (ROC) curve was used to determine the cut-off values of BMI and WC with optimum sensitivity and specificity for the detection of MCI. Age, gender, years of education, smoking habit, alcohol consumption, depression, and medical conditions were used as confounding factors in this analysis. A BMI cut-off value of 26 kg/m 2 (area under the receiver operating characteristic curve [AUC] 0.725; sensitivity 90.5%; specificity 38.8%) was appropriate in identifying the risk of getting MCI in both men and women. The optimum WC cut-offs for likelihood of MCI were 90 cm (AUC 0.745; sensitivity 78.0%; specificity 59.8%) for men and 82 cm (AUC 0.714; sensitivity 84.3%; specificity 49.7%) for women. The optimum calf circumference (CC) cut-off values for identifying MCI were 29 cm (AUC 0.731; sensitivity 72.6%; specificity 61.1%) for men and 26 cm (AUC 0.598; sensitivity 79.1%; specificity 45.3%) for women. The cut-off values could be advocated and used as part of the screening of MCI among older Malaysian adults. There is a need to further determine the predictive values of these cut-off points on outcomes through longitudinal study design.
Predictive factors of the nursing diagnosis sedentary lifestyle in people with high blood pressure.
Guedes, Nirla Gomes; Lopes, Marcos Venícios de Oliveira; Araujo, Thelma Leite de; Moreira, Rafaella Pessoa; Martins, Larissa Castelo Guedes
2011-01-01
To verify the reproducibility of defining the characteristics and related factors in order to identify a sedentary lifestyle in patients with high blood pressure. A cross-sectional study. 310 patients diagnosed with high blood pressure. Socio-demographics and variables related to defining the characteristics and related factors of a sedentary lifestyle. The coefficient Kappa was utilized to analyze the reproducibility. The sensitivity, specificity, and predictive value of the defining characteristics were also analyzed. Logistic regression was applied in the analysis of possible predictors. The defining characteristic with the greatest sensitivity was demonstrates physical deconditioning (98.92%). The characteristics chooses a daily routine lacking physical exercise and verbalizes preference for activities low in physical activity presented higher values of specificity (99.21% and 95.97%, respectively). The following indicators were identified as powerful predictors (85.2%) for the identification of a sedentary lifestyle: demonstrates physical deconditioning, verbalizes preference for activities low in physical activity, and lack of training for accomplishment of physical exercise. © 2010 Wiley Periodicals, Inc.
Bodien, Yelena G; Carlowicz, Cecilia A; Chatelle, Camille; Giacino, Joseph T
2016-03-01
To describe the sensitivity and specificity of Coma Recovery Scale-Revised (CRS-R) total scores in detecting conscious awareness. Data were retrospectively extracted from the medical records of patients enrolled in a specialized disorders of consciousness (DOC) program. Sensitivity and specificity analyses were completed using CRS-R-derived diagnoses of minimally conscious state (MCS) or emerged from minimally conscious state (EMCS) as the reference standard for conscious awareness and the total CRS-R score as the test criterion. A receiver operating characteristic curve was constructed to demonstrate the optimal CRS-R total cutoff score for maximizing sensitivity and specificity. Specialized DOC program. Patients enrolled in the DOC program (N=252, 157 men; mean age, 49y; mean time from injury, 48d; traumatic etiology, n=127; nontraumatic etiology, n=125; diagnosis of coma or vegetative state, n=70; diagnosis of MCS or EMCS, n=182). Not applicable. Sensitivity and specificity of CRS-R total scores in detecting conscious awareness. A CRS-R total score of 10 or higher yielded a sensitivity of .78 for correct identification of patients in MCS or EMCS, and a specificity of 1.00 for correct identification of patients who did not meet criteria for either of these diagnoses (ie, were diagnosed with vegetative state or coma). The area under the curve in the receiver operating characteristic curve analysis is .98. A total CRS-R score of 10 or higher provides strong evidence of conscious awareness but resulted in a false-negative diagnostic error in 22% of patients who demonstrated conscious awareness based on CRS-R diagnostic criteria. A cutoff score of 8 provides the best balance between sensitivity and specificity, accurately classifying 93% of cases. The optimal total score cutoff will vary depending on the user's objective. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Schlattmann, Peter; Verba, Maryna; Dewey, Marc; Walther, Mario
2015-01-01
Bivariate linear and generalized linear random effects are frequently used to perform a diagnostic meta-analysis. The objective of this article was to apply a finite mixture model of bivariate normal distributions that can be used for the construction of componentwise summary receiver operating characteristic (sROC) curves. Bivariate linear random effects and a bivariate finite mixture model are used. The latter model is developed as an extension of a univariate finite mixture model. Two examples, computed tomography (CT) angiography for ruling out coronary artery disease and procalcitonin as a diagnostic marker for sepsis, are used to estimate mean sensitivity and mean specificity and to construct sROC curves. The suggested approach of a bivariate finite mixture model identifies two latent classes of diagnostic accuracy for the CT angiography example. Both classes show high sensitivity but mainly two different levels of specificity. For the procalcitonin example, this approach identifies three latent classes of diagnostic accuracy. Here, sensitivities and specificities are quite different as such that sensitivity increases with decreasing specificity. Additionally, the model is used to construct componentwise sROC curves and to classify individual studies. The proposed method offers an alternative approach to model between-study heterogeneity in a diagnostic meta-analysis. Furthermore, it is possible to construct sROC curves even if a positive correlation between sensitivity and specificity is present. Copyright © 2015 Elsevier Inc. All rights reserved.
Sensitivity, Specificity, and Receiver Operating Characteristics: A Primer for Neuroscience Nurses.
McNett, Molly; Amato, Shelly; Olson, DaiWai M
2017-04-01
It is important for neuroscience nurses to have a solid understanding of the instruments they use in clinical practice. Specifically, when reviewing reports of research instruments, nurses should be knowledgeable of analytical terms when determining the applicability of instruments for use in clinical practice. The purpose of this article is to review 3 such analytical terms: sensitivity, specificity, and receiver operating characteristic curves. Examples of how these terms are used in the neuroscience literature highlight the relevance of these terms to neuroscience nursing practice. As the role of the nurse continues to expand, it is important not to simply accept all instruments as valid but to be able to critically evaluate their properties for applicability to nursing practice and evidence-based care of our patients.
Suh, Chong Hyun; Yun, Seong Jong; Jin, Wook; Lee, Sun Hwa; Park, So Young; Ryu, Chang-Woo
2018-07-01
To assess the sensitivity and specificity of quantitative assessment of the apparent diffusion coefficient (ADC) for differentiating benign and malignant vertebral bone marrow lesions (BMLs) and compression fractures (CFs) METHODS: An electronic literature search of MEDLINE and EMBASE was conducted. Bivariate modelling and hierarchical summary receiver operating characteristic modelling were performed to evaluate the diagnostic performance of ADC for differentiating vertebral BMLs. Subgroup analysis was performed for differentiating benign and malignant vertebral CFs. Meta-regression analyses according to subject, study and diffusion-weighted imaging (DWI) characteristics were performed. Twelve eligible studies (748 lesions, 661 patients) were included. The ADC exhibited a pooled sensitivity of 0.89 (95% confidence interval [CI] 0.80-0.94) and a pooled specificity of 0.87 (95% CI 0.78-0.93) for differentiating benign and malignant vertebral BMLs. In addition, the pooled sensitivity and specificity for differentiating benign and malignant CFs were 0.92 (95% CI 0.82-0.97) and 0.91 (95% CI 0.87-0.94), respectively. In the meta-regression analysis, the DWI slice thickness was a significant factor affecting heterogeneity (p < 0.01); thinner slice thickness (< 5 mm) showed higher specificity (95%) than thicker slice thickness (81%). Quantitative assessment of ADC is a useful diagnostic tool for differentiating benign and malignant vertebral BMLs and CFs. • Quantitative assessment of ADC is useful in differentiating vertebral BMLs. • Quantitative ADC assessment for BMLs had sensitivity of 89%, specificity of 87%. • Quantitative ADC assessment for CFs had sensitivity of 92%, specificity of 91%. • The specificity is highest (95%) with thinner (< 5 mm) DWI slice thickness.
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80-0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76-0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94-0.99) for the MC-PCR and 0.99 (95% PCI 0.99-1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997-1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83).
ERIC Educational Resources Information Center
Bowers, Alex J.; Sprott, Ryan; Taff, Sherry A.
2013-01-01
The purpose of this study is to review the literature on the most accurate indicators of students at risk of dropping out of high school. We used Relative Operating Characteristic (ROC) analysis to compare the sensitivity and specificity of 110 dropout flags across 36 studies. Our results indicate that 1) ROC analysis provides a means to compare…
Evaluation of clinical methods for diagnosing bacterial vaginosis.
Gutman, Robert E; Peipert, Jeffrey F; Weitzen, Sherry; Blume, Jeffrey
2005-03-01
To determine whether the current clinical criteria for diagnosing bacterial vaginosis can be simplified by using 2 clinical criteria rather than the standard 3 of 4 criteria (Amsel's criteria). This was a prospective observational study of 269 women undergoing a vaginal examination in the Women's Primary Care Center, Division of Research, or Colposcopy Clinic at Women & Infants Hospital. All 4 clinical criteria for diagnosing bacterial vaginosis were collected, and Gram stain was used as the gold standard. Sensitivity and specificity were calculated for each individual criterion, combinations of criteria, and a colorimetric pH and amine card. Receiver operating characteristic curve was generated to estimate the preferred pH and percentage of clue cells for diagnosing bacterial vaginosis. The prevalence of bacterial vaginosis in our study population was 38.7%. Vaginal pH was the most sensitive of all the criteria, at 89%, and a positive amine odor was the individual criteria with the highest specificity, at 93%. Similar specificity was seen with combinations of 2 criteria and Amsel's criteria. Receiver operating characteristic curve analysis yielded a preferred pH and percentage of clue cells of 5.0 and 20%, respectively. However, a pH of 4.5 or greater improves sensitivity with minimal loss of specificity. The clinical criteria for diagnosing bacterial vaginosis can be simplified to 2 clinical criteria without loss of sensitivity and specificity.
Zur, RM; Roy, LM; Ito, S; Beyene, J; Carew, C; Ungar, WJ
2016-01-01
Thiopurine S-methyltransferase (TPMT) deficiency increases the risk of serious adverse events in persons receiving thiopurines. The objective was to synthesize reported sensitivity and specificity of TPMT phenotyping and genotyping using a latent class hierarchical summary receiver operating characteristic meta-analysis. In 27 studies, pooled sensitivity and specificity of phenotyping for deficient individuals was 75.9% (95% credible interval (CrI), 58.3–87.0%) and 98.9% (96.3–100%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 90.4% (79.1–99.4%) and 100.0% (99.9–100%), respectively. For individuals with deficient or intermediate activity, phenotype sensitivity and specificity was 91.3% (86.4–95.5%) and 92.6% (86.5–96.6%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 88.9% (81.6–97.5%) and 99.2% (98.4–99.9%), respectively. Genotyping has higher sensitivity as long as TPMT*2 and TPMT*3 are tested. Both approaches display high specificity. Latent class meta-analysis is a useful method for synthesizing diagnostic test performance data for clinical practice guidelines. PMID:27217052
Ebner, Matthias; Birschmann, Ingvild; Peter, Andreas; Härtig, Florian; Spencer, Charlotte; Kuhn, Joachim; Blumenstock, Gunnar; Zuern, Christine S; Ziemann, Ulf; Poli, Sven
2017-09-01
In patients receiving direct oral anticoagulants (DOACs), emergency treatment like thrombolysis for acute ischemic stroke is complicated by insufficient availability of DOAC-specific coagulation tests. Conflicting recommendations have been published concerning the use of global coagulation assays for ruling out relevant DOAC-induced anticoagulation. Four hundred eighty-one samples from 96 DOAC-treated patients were tested using prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT), DOAC-specific assays (anti-Xa activity, diluted TT), and liquid chromatography-tandem mass spectrometry. Sensitivity and specificity of test results to identify DOAC concentrations <30 ng/mL were calculated. Receiver operating characteristic analyses were used to define reagent-specific cutoff values. Normal PT and aPTT provide insufficient specificity to safely identify DOAC concentrations <30 ng/mL (rivaroxaban/PT: specificity, 77%/sensitivity, 94%; apixaban/PT: specificity, 13%/sensitivity, 94%, dabigatran/aPTT: specificity, 49%/sensitivity, 91%). Normal TT was 100% specific for dabigatran, but sensitivity was 26%. In contrast, reagent-specific PT and aPTT cutoffs provided >95% specificity and a specific TT cutoff enhanced sensitivity for dabigatran to 84%. For apixaban, no cutoffs could be established. Even if highly DOAC-reactive reagents are used, normal results of global coagulation tests are not suited to guide emergency treatment: whereas normal PT and aPTT lack specificity to rule out DOAC-induced anticoagulation, the low sensitivity of normal TT excludes the majority of eligible patients from treatment. However, reagent-specific cutoffs for global coagulation tests ensure high specificity and optimize sensitivity for safe emergency decision making in rivaroxaban- and dabigatran-treated patients. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT02371044 and NCT02371070. © 2017 American Heart Association, Inc.
Reiff, Donald A; McGwin, Gerald; Metzger, Jesse; Windham, Samuel T; Doss, Marilyn; Rue, Loring W
2002-12-01
Diaphragmatic rupture (DR) remains a diagnostic challenge because of the lack of an accurate test demonstrating the injury. Our purpose was to identify motor vehicle collision (MVC) characteristics and patient injuries that collectively could identify the presence of a DR. The National Automotive Sampling System was used to identify occupants involved in MVCs from 1995 to 1999 who sustained abdominal (Abbreviated Injury Scale score >or= 2) and/or thoracic injuries (Abbreviated Injury Scale score >or= 2). Odds ratios (ORs) and 95% confidence intervals (CIs) were calculated to quantify the association between patient injuries, vehicle collision characteristics, and DR. Sensitivity and specificity were also calculated to determine the ability of organ injury and MVC characteristics to correctly classify patients with and without DR. Overall, occupants sustaining a DR had a significantly higher delta-V (DeltaV) (49.8 kilometers per hour [kph] vs. 33.8 kph, p< 0.0001) and a greater degree of occupant compartment intrusion (70.6 cm vs. 48.3 cm, p< 0.0001). Specific abdominal and thoracic organ injuries were associated with DR, including thoracic aortic tears (OR, 5.2; 95% CI, 2.2-12.5), splenic injury (OR, 8.4; 95% CI, 3.9-17.8), pelvic fractures (OR, 4.7; 95% CI, 2.7-8.0), and hepatic injuries (OR, 4.2; 95% CI, 1.7-10.6). Combining frontal or near-side lateral occupant compartment intrusion >or= 30 cm or DeltaV >or= 40 kph with specific organ injuries generated a sensitivity for indicating the likelihood of diaphragm injury ranging from 68% to 89%. Patients with any of the following characteristics had a sensitivity for detecting DR of 91%: splenic injury, pelvic fracture, DeltaV >or= 40 kph, or occupant compartment intrusion from any direction >or= 30 cm. Specific MVC characteristics combined with patient injuries have been identified that are highly suggestive of DR. For this subpopulation, additional invasive procedures including exploratory laparotomy, laparoscopy, or thoracoscopy may be warranted to exclude DR.
Sensitivity assessment of freshwater macroinvertebrates to pesticides using biological traits.
Ippolito, A; Todeschini, R; Vighi, M
2012-03-01
Assessing the sensitivity of different species to chemicals is one of the key points in predicting the effects of toxic compounds in the environment. Trait-based predicting methods have proved to be extremely efficient for assessing the sensitivity of macroinvertebrates toward compounds with non specific toxicity (narcotics). Nevertheless, predicting the sensitivity of organisms toward compounds with specific toxicity is much more complex, since it depends on the mode of action of the chemical. The aim of this work was to predict the sensitivity of several freshwater macroinvertebrates toward three classes of plant protection products: organophosphates, carbamates and pyrethroids. Two databases were built: one with sensitivity data (retrieved, evaluated and selected from the U.S. Environmental Protection Agency ECOTOX database) and the other with biological traits. Aside from the "traditional" traits usually considered in ecological analysis (i.e. body size, respiration technique, feeding habits, etc.), multivariate analysis was used to relate the sensitivity of organisms to some other characteristics which may be involved in the process of intoxication. Results confirmed that, besides traditional biological traits, related to uptake capability (e.g. body size and body shape) some traits more related to particular metabolic characteristics or patterns have a good predictive capacity on the sensitivity to these kinds of toxic substances. For example, behavioral complexity, assumed as an indicator of nervous system complexity, proved to be an important predictor of sensitivity towards these compounds. These results confirm the need for more complex traits to predict effects of highly specific substances. One key point for achieving a complete mechanistic understanding of the process is the choice of traits, whose role in the discrimination of sensitivity should be clearly interpretable, and not only statistically significant.
Didier, Ryne A; Hopkins, Katharine L; Coakley, Fergus V; Krishnaswami, Sanjay; Spiro, David M; Foster, Bryan R
2017-09-01
Magnetic resonance imaging (MRI) has emerged as a promising modality for evaluating pediatric appendicitis. However optimal imaging protocols, including roles of contrast agents and sedation, have not been established and diagnostic criteria have not been fully evaluated. To investigate performance characteristics of rapid MRI without contrast agents or sedation in the diagnosis of pediatric appendicitis. We included patients ages 4-18 years with suspicion of appendicitis who underwent rapid MRI between October 2013 and March 2015 without contrast agent or sedation. After two-radiologist review, we determined performance characteristics of individual diagnostic criteria and aggregate diagnostic criteria by comparing MRI results to clinical outcomes. We used receiver operating characteristic (ROC) curves to determine cut-points for appendiceal diameter and wall thickness for optimization of predictive power, and we calculated area under the curve (AUC) as a measure of test accuracy. Ninety-eight MRI examinations were performed in 97 subjects. Overall, MRI had a 94% sensitivity, 95% specificity, 91% positive predictive value and 97% negative predictive value. Optimal cut-points for appendiceal diameter and wall thickness were ≥7 mm and ≥2 mm, respectively. Independently, those cut-points produced sensitivities of 91% and 84% and specificities of 84% and 43%. Presence of intraluminal fluid (30/33) or localized periappendiceal fluid (32/33) showed a significant association with acute appendicitis (P<0.01), with sensitivities of 91% and 97% and specificities of 60% and 50%. For examinations in which the appendix was not identified by one or both reviewers (23/98), the clinical outcome was negative. Rapid MRI without contrast agents or sedation is accurate for diagnosis of pediatric appendicitis when multiple diagnostic criteria are considered in aggregate. Individual diagnostic criteria including optimized cut-points of ≥7 mm for diameter and ≥2 mm for wall thickness demonstrate high sensitivities but relatively low specificities. Nonvisualization of the appendix favors a negative diagnosis.
Estimating sensitivity and specificity for technology assessment based on observer studies.
Nishikawa, Robert M; Pesce, Lorenzo L
2013-07-01
The goal of this study was to determine the accuracy and precision of using scores from a receiver operating characteristic rating scale to estimate sensitivity and specificity. We used data collected in a previous study that measured the improvements in radiologists' ability to classify mammographic microcalcification clusters as benign or malignant with and without the use of a computer-aided diagnosis scheme. Sensitivity and specificity were estimated from the rating data from a question that directly asked the radiologists their biopsy recommendations, which was used as the "truth," because it is the actual recall decision, thus it is their subjective truth. By thresholding the rating data, sensitivity and specificity were estimated for different threshold values. Because of interreader and intrareader variability, estimated sensitivity and specificity values for individual readers could be as much as 100% in error when using rating data compared to using the biopsy recommendation data. When pooled together, the estimates using thresholding the rating data were in good agreement with sensitivity and specificity estimated from the recommendation data. However, the statistical power of the rating data estimates was lower. By simply asking the observer his or her explicit recommendation (eg, biopsy or no biopsy), sensitivity and specificity can be measured directly, giving a more accurate description of empirical variability and the power of the study can be maximized. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
Lúcia, Marc; Crespo, Elena; Melilli, Edoardo; Cruzado, Josep M.; Luque, Sergi; Llaudó, Inés; Niubó, Jordi; Torras, Joan; Fernandez, Núria; Grinyó, Josep M.; Bestard, Oriol
2014-01-01
Background. Cytomegalovirus (CMV) infection remains a major complication after kidney transplantation. Baseline CMV risk is typically determined by the serological presence of preformed CMV-specific immunoglobulin (Ig) G antibodies, even though T-cell responses to major viral antigens are crucial when controlling viral replication. Some IgG-seronegative patients who receive an IgG-seropositive allograft do not develop CMV infection despite not receiving prophylaxis. We hypothesized that a more precise evaluation of pretransplant CMV-specific immune-sensitization using the B and T-cell enzyme-linked immunospot assays may identify CMV-sensitized individuals more accurately, regardless of serological evidence of CMV-specific IgG titers. Methods. We compared the presence of preformed CMV-specific memory B and T cells in kidney transplant recipients between 43 CMV IgG–seronegative (sR−) and 86 CMV IgG–seropositive (sR+) patients. Clinical outcome was evaluated in both groups. Results. All sR+ patients showed a wide range of CMV-specific memory T- and B-cell responses. High memory T- and B-cell frequencies were also clearly detected in 30% of sR− patients, and those with high CMV-specific T-cell frequencies had a significantly lower incidence of late CMV infection after prophylactic therapy. Receiver operating characteristic curve analysis for predicting CMV viremia and disease showed a high area under the receiver operating characteristic curve (>0.8), which translated into a high sensitivity and negative predictive value of the test. Conclusions. Assessment of CMV-specific memory T- and B-cell responses before kidney transplantation among sR− recipients may help identify immunized individuals more precisely, being ultimately at lower risk for CMV infection. PMID:25048845
de Camargo, Kélvia Cristina; Alves, Rosane Ribeiro Figueiredo; Baylão, Luciano Augusto; Ribeiro, Andrea Alves; Araujo, Nadja Lindany Alves de Souza; Tavares, Suelene Brito do Nascimento; dos Santos, Sílvia Helena Rabelo
2015-05-01
To estimate the prevalence of bacterial vaginosis (BV), candidiasis and trichomoniasis and compare the findings of physical examination of the vaginal secretion with the microbiological diagnosis obtained by cytology study of a vaginal smear using the Papanicolaou method. A cross-sectional study of 302 women aged 20 to 87 years, interviewed and submitted to a gynecology test for the evaluation of vaginal secretion and collection of a cytology smear, from June 2012 to May 2013. Sensitivity analyses were carried out and specificity, positive predictive value (PPV) and negative predictive value (NPV) with their respective 95%CI were determined to assess the accuracy of the characteristics of vaginal secretion in relation to the microbiological diagnosis of the cytology smear . The kappa index (k) was used to assess the degree of agreement between the clinical features of vaginal secretion and the microbiological findings obtained by cytology. RESULTS The prevalence of BV, candidiasis and trichomoniasis was 25.5, 9.3 and 2.0%, respectively. The sensitivity, specificity, PPV and NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of BV were 74, 78.6, 54.3 and 89.9%, respectively. The sensitivity, specificity, PPV and the NPV of the clinical characteristics of vaginal secretion for the cytological diagnosis of candidiasis were 46.4, 86.2, 25.5 and 94%, respectively. The correlation between the clinical evaluation of vaginal secretion and the microbiological diagnosis of BV, candidiasis and trichomoniasis, assessed by the kappa index, was 0.47, 0.23 and 0.28, respectively. CONCLUSION The most common cause of abnormal vaginal secretion was BV. The clinical evaluation of vaginal secretion presented amoderate to weak agreement with the microbiological diagnosis, indicating the need for complementary investigation of the clinical findings of abnormal vaginal secretion.
Tafiadis, Dionysios; Kosma, Evangelia I; Chronopoulos, Spyridon K; Papadopoulos, Aggelos; Drosos, Konstantinos; Siafaka, Vassiliki; Toki, Eugenia I; Ziavra, Nausica
2018-01-01
The relationship between smoking and alterations of the vocal tract and larynx is well known. This pathology leads to the degradation of voice performance in daily living. Multiple assessment methods of vocal tract and larynx have been developed, and in recent years they were enriched with self-reported questionnaires such as Voice Handicap Index (VHI). This study determined the cutoff points of VHI's total score and its three domains for young female smokers in Greece. These estimated cutoff points could be used by voice specialists as an indicator for further clinical evaluation (foreseeing a potential risk of developing a vocal symptom because of smoking habits). A sample of 120 female nondysphonic smokers (aged 18-31) was recruited. Participants filled out the VHI and Voice Evaluation Form. VHI's cutoff point of total score was calculated at the value of 19.50 (sensitivity: 0.780, 1-specificity: 0.133). Specifically, the construct domain of functional was 7.50 (sensitivity: 0.900, 1-specificity: 0.217), for physical it was 8.50 (sensitivity: 0.867, 1-specificity: 0.483), and for emotional it was 7.50 (sensitivity: 0.833, 1-specificity: 0.200) through the use of receiver operating characteristic. Furthermore, VHI could be used as a monitoring tool for smokers and as a feedback for smoking cessation. Copyright © 2018 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Tafiadis, Dionysios; Chronopoulos, Spyridon K; Kosma, Evangelia I; Voniati, Louiza; Raptis, Vasilis; Siafaka, Vasiliki; Ziavra, Nausica
2017-07-11
Voice performance is an inextricable key factor of everyday life. Obviously, the deterioration of voice quality can cause various problems to human communication and can therefore reduce the performance of social skills (relevant to voice). The deterioration could be originated from changes inside the system of the vocal tract and larynx. Various prognostic methods exist, and among them is the Voice Handicap Index (VHI). This tool includes self-reported questionnaires, used for determining the cutoff points of total score and of its three domains relevant to young male Greek smokers. The interpretation of the calculated cutoff points can serve as a strong indicator of imminent or future evaluation by a clinician. Consistent with previous calculation, the VHI can also act as a feedback for smokers' voice condition and as monitoring procedure toward smoking cessation. Specifically, the sample consisted of 130 male nondysphonic smokers (aged 18-33 years) who all participated in the VHI test procedure. The test results (through receiver operating characteristic analysis) concluded to a total cutoff point score of 19.50 (sensitivity: 0.838, 1-specificity: 0). Also, in terms of constructs, the Functional domain was equal to 7.50 (sensitivity: 0.676, 1-specificity: 0.032), the Physical domain was equal to 7.50 (sensitivity: 0.706, 1-specificity: 0.032), and the Emotional domain was equal to 6.50 (sensitivity: 0.809, 1-specificity: 0.048). Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Automated analysis of retinal images for detection of referable diabetic retinopathy.
Abràmoff, Michael D; Folk, James C; Han, Dennis P; Walker, Jonathan D; Williams, David F; Russell, Stephen R; Massin, Pascale; Cochener, Beatrice; Gain, Philippe; Tang, Li; Lamard, Mathieu; Moga, Daniela C; Quellec, Gwénolé; Niemeijer, Meindert
2013-03-01
The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. A total of 874 people with diabetes at risk for DR. Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment.
Won, Huiloo; Abdul, Manaf Zahara; Mat Ludin, Arimi Fitri; Omar, Mohd Azahadi; Razali, Rosdinom; Shahar, Suzana
2017-01-01
Purpose Older adults are at risk of mild cognitive impairment (MCI), and simple anthropometric measurements can be used to screen for this condition. Thus, the aim of this study was to explore the cut-off values of body mass index (BMI) and waist circumference (WC) for predicting the risk of MCI in older Malaysian adults. Methods A total of 2,240 Malaysian older adults aged ≥60 years were recruited using multistage random sampling in a population based cross-sectional study. Receiver operating characteristic (ROC) curve was used to determine the cut-off values of BMI and WC with optimum sensitivity and specificity for the detection of MCI. Age, gender, years of education, smoking habit, alcohol consumption, depression, and medical conditions were used as confounding factors in this analysis. Results A BMI cut-off value of 26 kg/m2 (area under the receiver operating characteristic curve [AUC] 0.725; sensitivity 90.5%; specificity 38.8%) was appropriate in identifying the risk of getting MCI in both men and women. The optimum WC cut-offs for likelihood of MCI were 90 cm (AUC 0.745; sensitivity 78.0%; specificity 59.8%) for men and 82 cm (AUC 0.714; sensitivity 84.3%; specificity 49.7%) for women. The optimum calf circumference (CC) cut-off values for identifying MCI were 29 cm (AUC 0.731; sensitivity 72.6%; specificity 61.1%) for men and 26 cm (AUC 0.598; sensitivity 79.1%; specificity 45.3%) for women. Conclusion The cut-off values could be advocated and used as part of the screening of MCI among older Malaysian adults. There is a need to further determine the predictive values of these cut-off points on outcomes through longitudinal study design. PMID:28223785
Chen, Sam Li-Sheng; Hsu, Chen-Yang; Yen, Amy Ming-Fang; Young, Graeme P; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Lee, Yi-Chia; Chiu, Han-Mo; Chiou, Shu-Ti; Chen, Hsiu-Hsi
2018-06-01
Background: Despite age and sex differences in fecal hemoglobin (f-Hb) concentrations, most fecal immunochemical test (FIT) screening programs use population-average cut-points for test positivity. The impact of age/sex-specific threshold on FIT accuracy and colonoscopy demand for colorectal cancer screening are unknown. Methods: Using data from 723,113 participants enrolled in a Taiwanese population-based colorectal cancer screening with single FIT between 2004 and 2009, sensitivity and specificity were estimated for various f-Hb thresholds for test positivity. This included estimates based on a "universal" threshold, receiver-operating-characteristic curve-derived threshold, targeted sensitivity, targeted false-positive rate, and a colonoscopy-capacity-adjusted method integrating colonoscopy workload with and without age/sex adjustments. Results: Optimal age/sex-specific thresholds were found to be equal to or lower than the universal 20 μg Hb/g threshold. For older males, a higher threshold (24 μg Hb/g) was identified using a 5% false-positive rate. Importantly, a nonlinear relationship was observed between sensitivity and colonoscopy workload with workload rising disproportionately to sensitivity at 16 μg Hb/g. At this "colonoscopy-capacity-adjusted" threshold, the test positivity (colonoscopy workload) was 4.67% and sensitivity was 79.5%, compared with a lower 4.0% workload and a lower 78.7% sensitivity using 20 μg Hb/g. When constrained on capacity, age/sex-adjusted estimates were generally lower. However, optimizing age/-sex-adjusted thresholds increased colonoscopy demand across models by 17% or greater compared with a universal threshold. Conclusions: Age/sex-specific thresholds improve FIT accuracy with modest increases in colonoscopy demand. Impact: Colonoscopy-capacity-adjusted and age/sex-specific f-Hb thresholds may be useful in optimizing individual screening programs based on detection accuracy, population characteristics, and clinical capacity. Cancer Epidemiol Biomarkers Prev; 27(6); 704-9. ©2018 AACR . ©2018 American Association for Cancer Research.
Sumino, Kaharu; Sugar, Elizabeth A; Irvin, Charles G; Kaminsky, David A; Shade, Dave; Wei, Christine Y; Holbrook, Janet T; Wise, Robert A; Castro, Mario
2012-07-01
The methacholine challenge test (MCT) is commonly used to assess airway hyperresponsiveness, but the diagnostic characteristics have not been well studied in asthmatic patients receiving controller medications after the use of high-potency inhaled corticosteroids became common. We investigated the ability of the MCT to differentiate participants with a physician's diagnosis of asthma from nonasthmatic participants. We conducted a cohort-control study in asthmatic participants (n= 126) who were receiving regular controller medications and nonasthmatic control participants (n= 93) to evaluate the sensitivity and specificity of the MCT. The overall sensitivity was 77% and the specificity was 96% with a threshold PC(20) (the provocative concentration of methacholine that results in a 20% drop in FEV(1)) of 8 mg/mL. The sensitivity was significantly lower in white than in African American participants (69% vs 95%, P= .015) and higher in atopic compared with nonatopic (82% vs 52%, P= .005). Increasing the PC(20) threshold from 8 to 16 mg/mL did not noticeably improve the performance characteristics of the test. African American race, presence of atopy, and lower percent predicted FEV(1) were associated with a positive test result. The utility of the MCT to rule out a diagnosis of asthma depends on racial and atopic characteristics. Clinicians should take into account the reduced sensitivity of the MCT in white and nonatopic asthmatic patients when using this test for the diagnosis of asthma. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Meta-analysis of the relative sensitivity of semi-natural vegetation species to ozone.
Hayes, F; Jones, M L M; Mills, G; Ashmore, M
2007-04-01
This study identified 83 species from existing publications suitable for inclusion in a database of sensitivity of species to ozone (OZOVEG database). An index, the relative sensitivity to ozone, was calculated for each species based on changes in biomass in order to test for species traits associated with ozone sensitivity. Meta-analysis of the ozone sensitivity data showed a wide inter-specific range in response to ozone. Some relationships in comparison to plant physiological and ecological characteristics were identified. Plants of the therophyte lifeform were particularly sensitive to ozone. Species with higher mature leaf N concentration were more sensitive to ozone than those with lower leaf N concentration. Some relationships between relative sensitivity to ozone and Ellenberg habitat requirements were also identified. In contrast, no relationships between relative sensitivity to ozone and mature leaf P concentration, Grime's CSR strategy, leaf longevity, flowering season, stomatal density and maximum altitude were found. The relative sensitivity of species and relationships with plant characteristics identified in this study could be used to predict sensitivity to ozone of untested species and communities.
Dalbeth, Nicola; Schumacher, H Ralph; Fransen, Jaap; Neogi, Tuhina; Jansen, Tim L; Brown, Melanie; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Eliseev, Maxim; McCarthy, Geraldine; Stamp, Lisa K; Perez-Ruiz, Fernando; Sivera, Francisca; Ea, Hang-Korng; Gerritsen, Martijn; Scire, Carlo A; Cavagna, Lorenzo; Lin, Chingtsai; Chou, Yin-Yi; Tausche, Anne-Kathrin; da Rocha Castelar-Pinheiro, Geraldo; Janssen, Matthijs; Chen, Jiunn-Horng; Cimmino, Marco A; Uhlig, Till; Taylor, William J
2016-12-01
To identify the best-performing survey definition of gout from items commonly available in epidemiologic studies. Survey definitions of gout were identified from 34 epidemiologic studies contributing to the Global Urate Genetics Consortium (GUGC) genome-wide association study. Data from the Study for Updated Gout Classification Criteria (SUGAR) were randomly divided into development and test data sets. A data-driven case definition was formed using logistic regression in the development data set. This definition, along with definitions used in GUGC studies and the 2015 American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) gout classification criteria were applied to the test data set, using monosodium urate crystal identification as the gold standard. For all tested GUGC definitions, the simple definition of "self-report of gout or urate-lowering therapy use" had the best test performance characteristics (sensitivity 82%, specificity 72%). The simple definition had similar performance to a SUGAR data-driven case definition with 5 weighted items: self-report, self-report of doctor diagnosis, colchicine use, urate-lowering therapy use, and hyperuricemia (sensitivity 87%, specificity 70%). Both of these definitions performed better than the 1977 American Rheumatism Association survey criteria (sensitivity 82%, specificity 67%). Of all tested definitions, the 2015 ACR/EULAR criteria had the best performance (sensitivity 92%, specificity 89%). A simple definition of "self-report of gout or urate-lowering therapy use" has the best test performance characteristics of existing definitions that use routinely available data. A more complex combination of features is more sensitive, but still lacks good specificity. If a more accurate case definition is required for a particular study, the 2015 ACR/EULAR gout classification criteria should be considered. © 2016, American College of Rheumatology.
Cighetti, Giuliana; Bamonti, Fabrizia; Aman, Caroline S; Gregori, Dario; De Giuseppe, Rachele; Novembrino, Cristina; de Liso, Federica; Maiavacca, Rita; Paroni, Rita
2015-01-01
To test the performance of different analytical approaches in highlighting the occurrence of deregulated redox status in various physio-pathological situations. 35 light and 61 heavy smokers, 19 chronic renal failure, 59 kidney transplanted patients, and 87 healthy controls were retrospectively considered for the study. Serum oxidative stress and antioxidant status, assessed by spectrophotometric Reactive Oxygen Metabolites (d-ROMs) and Total Antioxidant Capacity (TAC) tests, respectively, were compared with plasma free (F-MDA) and total (T-MDA) malondialdehyde, both quantified by isotope-dilution-gas chromatography-mass spectrometry (ID-GC-MS). Sensitivity, specificity and cut-off points of T-MDA, F-MDA, d-ROMs and TAC were evaluated by both Receiver Operating Characteristic (ROC) analyses and area under the ROC curve (AUC). Only T-MDA assay showed a clear absence of oxidative stress in controls and significant increase in all patients (AUC 1.00, sensitivity and specificity 100%). Accuracy was good for d-ROMs (AUC 0.87, sensitivity 72.8%, specificity 100%) and F-MDA (AUC 0.82, sensitivity 74.7%, specificity 83.9%), but not high enough for TAC to show in patients impaired antioxidant defense (AUC 0.66, sensitivity 52.0%, specificity 92.9%). This study reveals T-MDA as the best marker to detect oxidative stress, shows the ability of d-ROMs to identify modified oxidative status particularly in the presence of high damages, and evidences the poor TAC performance. d-ROMs and TAC assays could be useful for routine purposes; however, for an accurate clinical data evaluation, their comparison versus a "gold standard method" is required. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Grosso, Matthew J; Frangiamore, Salvatore J; Ricchetti, Eric T; Bauer, Thomas W; Iannotti, Joseph P
2014-03-19
Propionibacterium acnes is a clinically relevant pathogen with total shoulder arthroplasty. The purpose of this study was to determine the sensitivity of frozen section histology in identifying patients with Propionibacterium acnes infection during revision total shoulder arthroplasty and investigate various diagnostic thresholds of acute inflammation that may improve frozen section performance. We reviewed the results of forty-five patients who underwent revision total shoulder arthroplasty. Patients were divided into the non-infection group (n = 15), the Propionibacterium acnes infection group (n = 18), and the other infection group (n = 12). Routine preoperative testing was performed and intraoperative tissue culture and frozen section histology were collected for each patient. The histologic diagnosis was determined by one pathologist for each of the four different thresholds. The absolute maximum polymorphonuclear leukocyte concentration was used to construct a receiver operating characteristics curve to determine a new potential optimal threshold. Using the current thresholds for grading frozen section histology, the sensitivity was lower for the Propionibacterium acnes infection group (50%) compared with the other infection group (67%). The specificity of frozen section was 100%. Using a receiver operating characteristics curve, an optimized threshold was found at a total of ten polymorphonuclear leukocytes in five high-power fields (400×). Using this threshold, the sensitivity of frozen section for Propionibacterium acnes was increased to 72%, and the specificity remained at 100%. Using current histopathology grading systems, frozen sections were specific but showed low sensitivity with respect to the Propionibacterium acnes infection. A new threshold value of a total of ten or more polymorphonuclear leukocytes in five high-power fields may increase the sensitivity of frozen section, with minimal impact on specificity.
Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.
Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C
2016-06-01
The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.
NASA Technical Reports Server (NTRS)
Traversi, M.
1979-01-01
Data are presented on the sensitivity of: (1) mission analysis results to the boundary values given for number of passenger cars and average annual vehicle miles traveled per car; (2) vehicle characteristics and performance to specifications; and (3) tradeoff study results to the expected parameters.
Yu, Fang Fang; Ping, Zhi Guang; Yao, Chong; Wang, Zhi Wen; Wang, Fu Qi; Guo, Xiong
2017-02-01
This study aimed to evaluate the sensitivity and specificity of the new clinical diagnostic and classification criteria for Kashin-Beck disease (KBD) using six clinical markers: flexion of the distal part of fingers, deformed fingers, enlarged finger joints, shortened fingers, squat down, and dwarfism. One-third of the total population in Linyou County was sampled by stratified random sampling. The survey included baseline characteristics and clinical diagnoses, and the sensitivity and specificity of the new criteria was evaluated. We identified 3,459 KBD patients, of which 69 had early stage KBD, 1,952 had stage I, 1,132 had stage II, and 306 had stage III. A screening test classified enlarged finger joints as stage I KBD, with a sensitivity and specificity of 0.978 and 0.045, respectively. Shortened fingers were classified as stage II KBD, with a sensitivity and specificity of 0.969 and 0.844, respectively, and dwarfism was classified as stage III KBD with a sensitivity and specificity of 0.951 and 0.992, respectively. Serial screening test revealed that the new clinical classification of KBD classified stages I, II, and III KBD with sensitivities of 0.949, 0.945, and 0.925 and specificities of 0.967, 0.970, and 0.993, respectively. The screening tests revealed that enlarged finger joints, shortened fingers, and dwarfism were appropriate markers for the clinical diagnosis and classification of KBD with high sensitivity and specificity. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Kaszás, B; Kovács, N; Balás, I; Kállai, J; Aschermann, Z; Kerekes, Z; Komoly, S; Nagy, F; Janszky, J; Lucza, T; Karádi, K
2012-06-01
Among the non-motor features of Parkinson's disease (PD), cognitive impairment is one of the most troublesome problems. Highly sensitive and specific screening instruments for detecting dementia in PD (PDD) are required in the clinical practice. In our study we evaluated the sensitivity and specificity of different neuropsychological tests (Addenbrooke's Cognitive Examination, ACE; Frontal Assessment Battery, FAB and Mattis Dementia Rating Scale, MDRS) in 73 Parkinson's disease patients without depression. By receiver operating characteristic curve analysis, these screening instruments were tested against the recently established clinical diagnostic criteria of PDD. Best cut-off score for ACE to identify PDD was 80 points (sensitivity = 74.0%, specificity = 78.1%). For FAB the most optimal cut-off value was 12 points (sensitivity = 66.3%, specificity = 72.2%); whereas for MDRS it was 125 points (sensitivity = 89.8%, specificity = 98.3%). Among the examined test batteries, MDRS had the best clinicometric profile for detecting PDD. Although the types of applied screening instruments might differ from movement disorder clinic to clinic within a country, determination of the most specific and sensitive test for the given population remains to be an important task. Our results demonstrated that the specificity and sensitivity of MDRS was better than those of ACE, FAB and MMSE in Hungary. However, further studies with larger sample size and more uniform criteria for participation are required to determine the most suitable screening instrument for cognitive impairment. Copyright © 2012 Elsevier Ltd. All rights reserved.
Larson, R N; Ginn, J A; Bell, C M; Davis, M J; Foy, D S
2012-01-01
The diagnosis of intestinal lymphangiectasia (IL) has been associated with characteristic duodenal mucosal changes. However, the sensitivity and specificity of the endoscopic duodenal mucosal appearance for the diagnosis of IL are not reported. To evaluate the utility of endoscopic images of the duodenum for diagnosis of IL. Endoscopic appearance of the duodenal mucosal might predict histopathologic diagnosis of IL with a high degree of sensitivity and specificity. 51 dogs that underwent upper gastrointestinal (GI) endoscopy and endoscopic biopsies. Retrospective review of images acquired during endoscopy. Dogs were included if adequate biopsies were obtained during upper GI endoscopy and digital images were saved during the procedure. Images were assessed for the presence and severity of IL. Using histopathology as the gold standard, the sensitivity and specificity of endoscopy for diagnosing IL were calculated. Intestinal lymphangiectasia (IL) was diagnosed in 25/51 dogs. Gross endoscopic appearance of the duodenal mucosa had a sensitivity and specificity (95% confidence interval) of 68% (46%, 84%) and 42% (24%, 63%), respectively for diagnosis of IL. Endoscopic images in cases with lymphopenia, hypocholesterolemia, and hypoalbuminemia had a sensitivity of 80%. Endoscopic duodenal mucosa appearance alone lacks specificity and has only a moderate sensitivity for diagnosis of IL. Evaluation of biomarkers associated with PLE improved the sensitivity; however, poor specificity for diagnosis of IL supports the need for histopathologic confirmation. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Wahlström, Helene; Comin, Arianna; Isaksson, Mats; Deplazes, Peter
2016-01-01
Introduction A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR), allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT) as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Materials and methods Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108) and autumn 2012 (n=69) in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. Results and discussion This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI) 0.80–0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76–0.88), which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94–0.99) for the MC-PCR and 0.99 (95% PCI 0.99–1) for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997–1). One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. Conclusion The sensitivity of the MC-PCR (0.88) was comparable to the sensitivity of SCT (0.83). PMID:26968153
Motamed, Nima; Miresmail, Seyed Javad Haji; Rabiee, Behnam; Keyvani, Hossein; Farahani, Behzad; Maadi, Mansooreh; Zamani, Farhad
2016-03-01
The present study was carried out to determine the optimal cutoff points for homeostatic model assessment (HOMA-IR) and quantitative insulin sensitivity check index (QUICKI) in the diagnosis of metabolic syndrome (MetS) and non-alcoholic fatty liver disease (NAFLD). The baseline data of 5511 subjects aged ≥18years of a cohort study in northern Iran were utilized to analyze. Receiver operating characteristic (ROC) analysis was conducted to determine the discriminatory capability of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. Youden index was utilized to determine the optimal cutoff points of HOMA-IR and QUICKI in the diagnosis of MetS and NAFLD. The optimal cutoff points for HOMA-IR in the diagnosis of MetS and NAFLD were 2.0 [sensitivity=64.4%, specificity=66.8%] and 1.79 [sensitivity=66.2%, specificity=62.2%] in men and were 2.5 [sensitivity=57.6%, specificity=67.9%] and 1.95 [sensitivity=65.1%, specificity=54.7%] in women respectively. Furthermore, the optimal cutoff points for QUICKI in the diagnosis of MetS and NAFLD were 0.343 [sensitivity=63.7%, specificity=67.8%] and 0.347 [sensitivity=62.9%, specificity=65.0%] in men and were 0.331 [sensitivity=55.7%, specificity=70.7%] and 0.333 [sensitivity=53.2%, specificity=67.7%] in women respectively. Not only the optimal cutoff points of HOMA-IR and QUICKI were different for MetS and NAFLD, but also different cutoff points were obtained for men and women for each of these two conditions. Copyright © 2016 Elsevier Inc. All rights reserved.
Gelaw, Baye; Shiferaw, Yitayal; Alemayehu, Marta; Bashaw, Abate Assefa
2017-01-17
Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture. A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen's kappa was calculated as a measure of agreement between the tests. A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001). TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
Page, Iain D; Richardson, Malcolm D; Denning, David W
2016-02-01
Chronic pulmonary aspergillosis (CPA) is estimated to affect 3 million persons worldwide. Aspergillus-specific IgG is a key component in CPA diagnosis. We aimed to establish the optimal diagnostic cut offs for CPA and the comparative performance of six assays in this context. Sera from 241 patients with CPA and 100 healthy blood donors were tested using five Aspergillus-specific IgG assays plus precipitin testing using Microgen Aspergillus antigens. Receiver operating characteristic (ROC) curve area under the curve (AUC) results were as follows: ThermoFisher Scientific ImmunoCAP 0.996 (95% confidence interval 0.992-1), Siemens Immulite 0.991 (0.982-1), Serion 0.973 (0.960-0.987), Dynamiker 0.918 (0.89-0.946) and Genesis 0.902 (0.871-0.933). Optimal CPA diagnostic cut-offs were; ImmunoCAP 20 mg/L (96% sensitivity, 98% specificity), Immulite 10 mg/L (96% sensitivity, 98% specificity), Serion 35 U/ml (90% sensitivity, 98% specificity), Dynamiker 65 AU/ml (77% sensitivity, 97% specificity) and Genesis 20 U/ml (75% sensitivity, 99% specificity). The precipitin test was 59% sensitive and 100% specific. ImmunoCAP and Immulite were statistically significantly superior to the other assays. Precipitins testing performed poorly. The currently accepted ImmunoCAP cut-off of 40 mg/L appears sub-optimal for CPA diagnosis and may require revision in this context. Copyright © 2015 The British Infection Association. Published by Elsevier Ltd. All rights reserved.
WASP (Write a Scientific Paper) using Excel - 11: Test characteristics.
Grech, Victor
2018-07-01
The calculation of various test characteristics may be required as part of a data analysis exercise. This paper explains how to set up these calculations in Microsoft Excel in order to obtain sensitivity, specificity, positive and negative predictive values, diagnostic accuracy and prevalence. Copyright © 2018 Elsevier B.V. All rights reserved.
Yang, Yong; Jiang, Yu; Xu, Yanqing; Mzayek, Fawaz; Levy, Marian
2018-03-01
To examine the influence of neighborhood environment on childhood overweight and obesity in Shelby County Schools, Tennessee, and whether and to what extent that influence varies by age, gender, and the specific environment characteristics. 41,283 students were surveyed covering both individual-level covariates and several objective measures of neighborhood environment. Multilevel logistic regressions were used to examine the influence of neighborhood-level variables on overweight+obesity and obesity with adjustment of individual-level covariates. Further, a stratified analysis for each of the six groups by school level and gender. For both overweight+obesity and obesity, younger children were less sensitive to neighborhood characteristics than older children, and boys are less sensitive than girls. For girls in middle and high schools, the risk of overweight+obesity and obesity were positively associated with population density, and negatively associated with percent of poverty and percent of unhealthy food. Boys' risk of overweight+obesity and obesity were positively associated with distance to park. Neighborhood environment plays an important role in childhood overweight and obesity, and the effects vary by age, gender, and the specific neighborhood characteristic. Intervention programs tailored to specific groups may be more effective than ones targeted to children as a whole. Copyright © 2018 Elsevier Inc. All rights reserved.
Tagliafico, Alberto Stefano; Bignotti, Bianca; Rossi, Federica; Signori, Alessio; Sormani, Maria Pia; Valdora, Francesca; Calabrese, Massimo; Houssami, Nehmat
2016-08-01
To estimate sensitivity and specificity of CESM for breast cancer diagnosis. Systematic review and meta-analysis of the accuracy of CESM in finding breast cancer in highly selected women. We estimated summary receiver operating characteristic curves, sensitivity and specificity according to quality criteria with QUADAS-2. Six hundred four studies were retrieved, 8 of these reporting on 920 patients with 994 lesions, were eligible for inclusion. Estimated sensitivity from all studies was: 0.98 (95% CI: 0.96-1.00). Specificity was estimated from six studies reporting raw data: 0.58 (95% CI: 0.38-0.77). The majority of studies were scored as at high risk of bias due to the very selected populations. CESM has a high sensitivity but very low specificity. The source studies were based on highly selected case series and prone to selection bias. High-quality studies are required to assess the accuracy of CESM in unselected cases. Copyright © 2016 Elsevier Ltd. All rights reserved.
CSF soluble amyloid precursor proteins in the diagnosis of incipient Alzheimer disease.
Perneczky, R; Tsolakidou, A; Arnold, A; Diehl-Schmid, J; Grimmer, T; Förstl, H; Kurz, A; Alexopoulos, P
2011-07-05
To explore if soluble amyloid precursor proteins (sAPP) in CSF improve the identification of patients with incipient Alzheimer disease (AD) in a group of patients with mild cognitive impairment (MCI). A cohort study with follow-up assessments of 58 patients with MCI with baseline CSF sampling was conducted: 21 patients had progressed to probable AD (MCI-AD), 27 still had MCI, 8 had reverted to normal (MCI-NAD), and 2 patients with frontotemporal dementia (FTD) were excluded. Sixteen additional patients with FTD were included to explore the specificity of the CSF markers. CSF concentrations of sAPPα, sAPPβ, tau, and Aβ(1-42) were measured with sensitive and specific ELISAs. Associations between diagnostic status, CSF protein concentrations, and other patient characteristics were explored using multiple logistic regression analyses with stepwise variable selection. The optimal sensitivity and specificity of the best models were derived from receiver operating characteristic curves. The MCI-AD group had significantly higher sAPPβ concentrations than the MCI-NAD and the FTD groups. A combination of sAPPβ, tau, and age differentiated the MCI-AD and the MCI-NAD groups with a sensitivity of 80.00% and a specificity of 81.00%. The best model for the differentiation of the MCI-AD and the FTD groups included sAPPβ and tau, and showed a sensitivity of 95.20% and a specificity of 81.20%. Aβ(1-42) and sAPPα did not significantly contribute to the models. These findings suggest that sAPPβ may be clinically useful, and superior to Aβ(1-42), in the early and differential diagnosis of incipient AD.
The Clinical Impact of Bet v 6 in Birch Pollen-Sensitized Patients.
Gellrich, Donata; Eder, Katharina; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz
2017-01-01
Bet v 6, a minor birch pollen allergen, is commercially available for allergen-specific IgE antibody testing. However, there is hardly any literature on the clinical impact of Bet v 6. The aim of the present study was to analyze if testing specific IgE against Bet v 6 can add valuable benefit to the standard diagnostics of birch pollen-sensitized patients, especially in patients with unknown sensitization-eliciting allergens. Birch pollen-sensitized patients with missing IgE reactivity against Bet v 1, 2, and 4 were tested for specific IgE antibodies against Bet v 6. For comparison, an equal number of randomly selected patients with birch pollen sensitization, regardless of their individual sensitization patterns, were tested for specific anti-Bet v 6. Of 57 cases with missing reactivity against the standard birch pollen allergens, 2 patients were positive for Bet v 6. In the representative sample, 3 patients showed specific IgE against Bet v 6 - resulting in a total prevalence of 5%. None of the Bet v 6-positive patients showed allergic symptoms after exposure to birch pollen or an oral allergy syndrome. An increased prevalence of asthma and a higher degree of sensitization were the only distinctive clinical features in Bet v 6-positive patients. Among birch pollen-sensitized patients, the prevalence of specific IgE against Bet v 6 is low. Further, sensitization to Bet v 6, which shows characteristics of a panallergen, remains clinically silent. Therefore, determination of anti-Bet v 6 is not considered useful in the clinical routine. © 2017 S. Karger AG, Basel.
Computer-aided detection in musculoskeletal projection radiography: A systematic review.
Gundry, M; Knapp, K; Meertens, R; Meakin, J R
2018-05-01
To investigated the accuracy of computer-aided detection (CAD) software in musculoskeletal projection radiography via a systematic review. Following selection screening, eligible studies were assessed for bias, and had their study characteristics extracted resulting in 22 studies being included. Of these 22 three studies had tested their CAD software in a clinical setting; the first study investigated vertebral fractures, reporting a sensitivity score of 69.3% with CAD, compared to 59.8% sensitivity without CAD. The second study tested dental caries diagnosis producing a sensitivity score of 68.8% and specificity of 94.1% with CAD, compared to sensitivity of 39.3% and specificity of 96.7% without CAD. The third indicated osteoporotic cases based on CAD, resulting in 100% sensitivity and 81.3% specificity. The current evidence reported shows a lack of development into the clinical testing phase; however the research does show future promise in the variation of different CAD systems. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Cameron, Janette D; Gallagher, Robyn; Pressler, Susan J; McLennan, Skye N; Ski, Chantal F; Tofler, Geoffrey; Thompson, David R
2016-02-01
Cognitive impairment occurs in up to 80% of patients with heart failure (HF). The National Institute for Neurological Disorders and Stroke (NINDS) and the Canadian Stroke Network (CSN) recommend a 5-minute cognitive screening protocol that has yet to be psychometrically evaluated in HF populations. The aim of this study was to conduct a secondary analysis of the sensitivity and specificity of the NINDS-CSN brief cognitive screening protocol in HF patients. The Montreal Cognitive Assessment (MoCA) was administered to 221 HF patients. The NINDS-CSN screen comprises 3 MoCA items, with lower scores indicating poorer cognitive function. Receiver operator characteristic (ROC) curves were constructed, determining the sensitivity, specificity and appropriate cutoff scores of the NINDS-CSN screen. In an HF population aged 76 ± 12 years, 136 (62%) were characterized with cognitive impairment (MoCA <26). Scores on the NINDS-CSN screen ranged from 3-11. The area under the receiver operating characteristic curve indicated good accuracy in screening for cognitive impairment (0.88; P < .01; 95% CI 0.83-0.92). A cutoff score of ≤9 provided 89% sensitivity and 71% specificity. The NINDS-CSN protocol offers clinicians a feasible telephone method to screen for cognitive impairment in patients with HF. Future studies should include a neuropsychologic battery to more comprehensively examine the diagnostic accuracy of brief cognitive screening protocols. Copyright © 2016 Elsevier Inc. All rights reserved.
Evaluation of posttransplantation soluble CD30 for diagnosis of acute renal allograft rejection.
Pelzl, Steffen; Opelz, Gerhard; Daniel, Volker; Wiesel, Manfred; Süsal, Caner
2003-02-15
Posttransplantation measurement of soluble CD30 (sCD30) may be useful for identifying kidney graft recipients at risk of impending graft rejection in the early posttransplantation period. We measured plasma sCD30 levels and evaluated the levels in relation to the diagnosis of rejection. Receiver operating characteristic curves demonstrated that on posttransplantation days 3 to 5, sCD30 allowed a differentiation of recipients who subsequently developed acute allograft rejection (n=25) from recipients with an uncomplicated course (n=20, P<0.0001) (area under the receiver operating characteristic curve 0.96, specificity 100%, sensitivity 88%) and recipients with acute tubular necrosis in the absence of rejection (n=11, P=0.001) (area under the receiver operating characteristic curve 0.85, specificity 91%, sensitivity 72%). sCD30 measured on posttransplantation days 3 to 5 offers a noninvasive means for differentiating patients with impending acute allograft rejection from patients with an uncomplicated course or with acute tubular necrosis.
Enhancing case definitions for surveillance of human monkeypox in the Democratic Republic of Congo.
Osadebe, Lynda; Hughes, Christine M; Shongo Lushima, Robert; Kabamba, Joelle; Nguete, Beatrice; Malekani, Jean; Pukuta, Elisabeth; Karhemere, Stomy; Muyembe Tamfum, Jean-Jacques; Wemakoy Okitolonda, Emile; Reynolds, Mary G; McCollum, Andrea M
2017-09-01
Human monkeypox (MPX) occurs at appreciable rates in the Democratic Republic of Congo (DRC). Infection with varicella zoster virus (VZV) has a similar presentation to that of MPX, and in areas where MPX is endemic these two illnesses are commonly mistaken. This study evaluated the diagnostic utility of two surveillance case definitions for MPX and specific clinical characteristics associated with laboratory-confirmed MPX cases. Data from a cohort of suspect MPX cases (identified by surveillance over the course of a 42 month period during 2009-2014) from DRC were used; real-time PCR diagnostic test results were used to establish MPX and VZV diagnoses. A total of 333 laboratory-confirmed MPX cases, 383 laboratory-confirmed VZV cases, and 36 cases that were determined to not be either MPX or VZV were included in the analyses. Significant (p<0.05) differences between laboratory-confirmed MPX and VZV cases were noted for several signs/symptoms including key rash characteristics. Both surveillance case definitions had high sensitivity and low specificities for individuals that had suspected MPX virus infections. Using 12 signs/symptoms with high sensitivity and/or specificity values, a receiver operator characteristic analysis showed that models for MPX cases that had the presence of 'fever before rash' plus at least 7 or 8 of the 12 signs/symptoms demonstrated a more balanced performance between sensitivity and specificity. Laboratory-confirmed MPX and VZV cases presented with many of the same signs and symptoms, and the analysis here emphasized the utility of including 12 specific signs/symptoms when investigating MPX cases. In order to document and detect endemic human MPX cases, a surveillance case definition with more specificity is needed for accurate case detection. In the absence of a more specific case definition, continued emphasis on confirmatory laboratory-based diagnostics is warranted.
Which Fecal Immunochemical Test Should I Choose?
Daly, Jeanette M.; Xu, Yinghui; Levy, Barcey T.
2017-01-01
Objectives: To summarize the fecal immunochemical tests (FITs) available in the United States, the 2014 pathology proficiency testing (PT) program FIT results, and the literature related to the test characteristics of FITs available in the United States to detect advanced adenomatous polyps (AAP) and/or colorectal cancer (CRC). Methods: Detailed review of the Food and Drug Administration’s Clinical Laboratory Improvement Amendments (CLIA) database of fecal occult blood tests, the 2014 FIT PT program results, and the literature related to FIT accuracy. Results: A search of the CLIA database identified 65 FITs, with 26 FITs available for purchase in the United States. Thirteen of these FITs were evaluated on a regular basis by PT programs, with an overall sensitivity of 99.1% and specificity of 99.2% for samples spiked with hemoglobin. Automated FITs had better sensitivity and specificity than CLIA-waived FITs for detection of AAP and CRC in human studies using colonoscopy as the gold standard. Conclusion: Although many FITs are available in the United States, few have been tested in proficiency testing programs. Even fewer have data in humans on sensitivity and specificity for AAP or CRC. Our review indicates that automated FITs have the best test characteristics for AAP and CRC. PMID:28447866
A proposed cutoff point of waist-to-height ratio for metabolic risk in African township adolescents.
Kruger, H Salome; Faber, Mieke; Schutte, Aletta E; Ellis, Suria M
2013-03-01
A waist:height ratio (WHtR) higher than 0.5 has been proposed as a cutoff point for abdominal obesity in both sexes and at all ages. It is unknown if this cutoff point is appropriate for previously undernourished adolescents. We assessed the cutoff value of the WHtR associated with an increased metabolic risk in 178 black South African 14- to 18-y-old adolescents (69 boys, 109 girls). We measured weight, height, waist circumference, fasting plasma glucose and insulin levels, serum high-sensitivity C-reactive protein, and blood pressure and calculated the WHtR and homeostasis model assessment of insulin resistance (HOMA-IR). Using receiver operating characteristics curve analyses, we assessed the WHtR with the highest sensitivity and specificity to discriminate adolescents with increased fasting plasma glucose, HOMA-IR, serum high-sensitivity C-reactive protein, and blood pressure from those with "normal" values. The WHtR cutoff points derived from the receiver operating characteristics curves ranged from 0.40 to 0.41, with best diagnostic value at 0.41. A WHtR of 0.40 had 80% sensitivity and 38.5% specificity to classify adolescents with fasting blood glucose level higher than 5.6 mmol/L (area under the curve [AUC] 0.57). A WHtR of 0.41 had 64% sensitivity and 58.5% specificity for a HOMA-IR higher than 3.4 (AUC 0.66), 55% sensitivity and 55.6% specificity for a high-sensitivity C-reactive protein level higher than 1 mg/L (AUC 0.57), and 64% sensitivity and 50.2% specificity for a blood pressure higher than the age-, sex-, and height-specific 90th percentiles (AUC 0.56). Adolescents with a WHtR higher than 0.41 had an odds ratio of 2.46 (95% confidence interval 0.96-6.30) for having a HOMA-IR higher than 3.4. The WHtR cutoff to indicate metabolic risk for black South African adolescents is 0.41, which is lower than the proposed international cutoff of 0.5. The WHtR can be used for screening adolescents with components of the metabolic syndrome in intervention programs. Copyright © 2013 Elsevier Inc. All rights reserved.
Performance characteristics of broth-only cultures after revision total joint arthroplasty.
Smith, Eric B; Cai, Jenny; Wynne, Rachael; Maltenfort, Mitchell; Good, Robert P
2014-11-01
Surgeons frequently obtain intraoperative cultures at the time of revision total joint arthroplasty. The use of broth or liquid medium before applying the sample to the agar medium may be associated with contamination and false-positive cultures; however, the degree to which this is the case is not known. We (1) calculated the performance characteristics of broth-only cultures (sensitivity, specificity, positive predictive value, and negative predictive value) and (2) characterized the organisms identified in broth to determine whether a specific organism showed increased proclivity for true-positive periprosthetic joint infection (PJI). A single-institution retrospective chart review was performed on 257 revision total joint arthroplasties from 2009 through 2010. One hundred ninety (74%) had cultures for review. All culture results, as well as treatment, if any, were documented and patients were followed for a minimum of 1 year for evidence of PJI. Cultures were measured as either positive from the broth only or broth negative. The true diagnosis of infection was determined by the Musculoskeletal Infection Society criteria during the preoperative workup or postoperatively at 1 year for purposes of calculating the performance characteristics of the broth-only culture. The sensitivity, specificity, positive predictive value, and negative predictive value were 19%, 88%, 13%, and 92%, respectively. The most common organism identified was coagulase-negative Staphylococcus (16 of 24 cases, 67%). Coagulase-negative Staphylococcus was present in all three true-positive cases; however, it was also found in 13 of the false-positive cases. The broth-only positive cultures showed poor sensitivity and positive predictive value but good specificity and negative predictive value. The good specificity indicates that it can help to rule in the presence of PJI; however, the poor sensitivity makes broth-only culture an unreliable screening test. We recommend that broth-only culture results be carefully scrutinized and decisions on the diagnosis and treatment of infection should be based specifically on the Musculoskeletal Infection Society criteria. Level IV, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.
Broski, Stephen M; Johnson, Geoffrey B; Howe, Benjamin M; Nathan, Mark A; Wenger, Doris E; Spinner, Robert J; Amrami, Kimberly K
2016-08-01
To compare 18F-FDG PET/CT and MRI for differentiating benign and malignant peripheral nerve sheath tumors (BPNSTs and MPNSTs) and correlate imaging characteristics with histopathology. Patients with pathologically proven PNSTs undergoing 18F-FDG PET/CT were retrospectively reviewed. PET/CTs and, if available, MRIs were analyzed, noting multiple imaging characteristics and likely pathology (benign or malignant). Thirty-eight patients with 23 BPNSTs and 20 MPNSTs were analyzed. MPNSTs had higher SUVmax (10.1 ± 1.0, 4.2 ± 0.4, p < 0.0001), metabolic tumor volume (146.5 ± 39.4, 21.7 ± 6.6 cm(3), p = 0.01), total lesion glycolysis (640.7 ± 177.5, 89.9 ± 23.2 cm(3)*g/ml, p = 0.01), and SUVmax/LiverSUVmean (5.3 ± 0.5, 2.0 ± 0.2, p < 0.0001). All lesions with SUVmax < 4.3 were benign. All lesions with SUVmax > 8.1 were malignant. SUVmax cutoff of 6.1 yielded 90.0 % sensitivity and 78.3 % specificity for MPNSTs. SUVmax/LiverSUVmean cutoff of 3.0 yielded 90.0 % sensitivity and 82.6 % specificity. MPNSTs more commonly had heterogeneous FDG activity (p < 0.0001), perilesional edema (p = 0.004), cystic degeneration/necrosis (p = 0.015), and irregular margins (p = 0.004). There was no difference in lesion size, MRI signal characteristics, or enhancement. Expertly interpreted MRI had 62.5-81.3 % sensitivity and 94.1-100.0 % specificity while PET had 90.0-100.0 % sensitivity and 52.2-82.6 % specificity for diagnosing MPNSTs. FDG PET and MRI play a complementary role in PNST evaluation. Multiple metabolic parameters and MRI imaging characteristics are useful in differentiating BPNSTs from MPNSTs. This underscores the potential critical role of PET/MRI in these patients.
Price, C L; Brace-McDonnell, S J; Stallard, N; Bleetman, A; Maconochie, I; Perkins, G D
2016-05-01
Context Triage tools are an essential component of the emergency response to a major incident. Although fortunately rare, mass casualty incidents involving children are possible which mandate reliable triage tools to determine the priority of treatment. To determine the performance characteristics of five major incident triage tools amongst paediatric casualties who have sustained traumatic injuries. Retrospective observational cohort study using data from 31,292 patients aged less than 16 years who sustained a traumatic injury. Data were obtained from the UK Trauma Audit and Research Network (TARN) database. Interventions Statistical evaluation of five triage tools (JumpSTART, START, CareFlight, Paediatric Triage Tape/Sieve and Triage Sort) to predict death or severe traumatic injury (injury severity score >15). Main outcome measures Performance characteristics of triage tools (sensitivity, specificity and level of agreement between triage tools) to identify patients at high risk of death or severe injury. Of the 31,292 cases, 1029 died (3.3%), 6842 (21.9%) had major trauma (defined by an injury severity score >15) and 14,711 (47%) were aged 8 years or younger. There was variation in the performance accuracy of the tools to predict major trauma or death (sensitivities ranging between 36.4 and 96.2%; specificities 66.0-89.8%). Performance characteristics varied with the age of the child. CareFlight had the best overall performance at predicting death, with the following sensitivity and specificity (95% CI) respectively: 95.3% (93.8-96.8) and 80.4% (80.0-80.9). JumpSTART was superior for the triaging of children under 8 years; sensitivity and specificity (95% CI) respectively: 86.3% (83.1-89.5) and 84.8% (84.2-85.5). The triage tools were generally better at identifying patients who would die than those with non-fatal severe injury. This statistical evaluation has demonstrated variability in the accuracy of triage tools at predicting outcomes for children who sustain traumatic injuries. No single tool performed consistently well across all evaluated scenarios. Copyright © 2015 Elsevier Ltd. All rights reserved.
The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.
Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar
2018-03-01
This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility (< 10 cycles per minute), and the difference between near and distance phoria (> 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near phoria, and monocular accommodative facility yield good sensitivity and specificity for diagnosis of NSBVAs in a community set-up. © 2017 Optometry Australia.
Teel, Elizabeth F; Gay, Michael R; Arnett, Peter A; Slobounov, Semyon M
2016-03-01
Balance assessments are part of the recommended clinical concussion evaluation, along with computerized neuropsychological testing and self-reported symptoms checklists. New technology has allowed for the creation of virtual reality (VR) balance assessments to be used in concussion care, but there is little information on the sensitivity and specificity of these evaluations. The purpose of this study is to establish the sensitivity and specificity of a VR balance module for detecting lingering balance deficits clinical concussion care. Retrospective case-control study. Institutional research laboratory. Normal controls (n = 94) and concussed participants (n = 27). All participants completed a VR balance assessment paradigm. Concussed participants were diagnosed by a Certified Athletic Trainer or physician (with 48 hours postinjury) and tested in the laboratory between 7 and 10 days postinjury. Receiver operating characteristic curves were performed to establish the VR module's sensitivity and specificity for detecting lingering balance deficits. Final balance score. For the VR balance module, a cutoff score of 8.25 was established to maximize sensitivity at 85.7% and specificity at 87.8%. The VR balance module has high sensitivity and specificity for detecting subacute balance deficits after concussive injury. The VR balance has a high subacute sensitivity and specificity as a stand-alone balance assessment tool and may detect ongoing balance deficits not readily detectable by the Balance Error Scoring System or Sensory Organization Test. Virtual reality balance modules may be a beneficial addition to the current clinical concussion diagnostic battery.
[Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].
Acevedo González, Juan C; Quintero Oliveros, Silvia
2015-01-01
Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
Kim, Daniel J; Francispragasam, Mario; Docherty, Gavin; Silver, Byron; Prager, Ross; Lee, Donna; Maberley, David
2018-05-18
Previous studies of point of care ultrasound (POCUS) have reported high sensitivities and specificities for retinal detachment (RD). Our primary objective was to assess the test characteristics of POCUS performed by a large heterogeneous group of emergency physicians (EPs) for the diagnosis of RD. This was a prospective diagnostic test assessment of POCUS performed by EPs with varying ultrasound experience on a convenience sample of emergency department (ED) patients presenting with flashes or floaters in one or both eyes. After standard ED assessment, EPs performed an ocular POCUS scan targeted to detect the presence or absence of RD. After completing their ED visit, all patients were assessed by a retina specialist who was blinded to the results of the POCUS scan. We calculated sensitivity and specificity with associated exact binomial confidence intervals (CI) using the retina specialist's final diagnosis as the reference standard. A total of 30 EPs enrolled 115 patients, with median age of 60 years and 64% female. The retina specialist diagnosed RD in 16 (14%) cases. The sensitivity and specificity of POCUS for detecting RD was 75% (95% CI 48%-93%) and 94% (95% CI 87%-98%), respectively. The positive likelihood ratio was 12.4 (95% CI 5.4-28.3), and negative likelihood ratio was 0.27 (95% CI 0.11-0.62). A large heterogeneous group of EPs can perform POCUS with high specificity but only intermediate sensitivity for RD. A negative POCUS scan in the ED performed by a heterogeneous group of providers after a one-hour POCUS didactic is not sufficiently sensitive to rule out RD in a patient with new onset flashes or floaters. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
[Situational low self-esteem in pregnant women: an analysis of accuracy].
Cavalcante, Joyce Carolle Bezerra; de Sousa, Vanessa Emille Carvalho; Lopes, Marcos Venícios de Oliveira
2012-01-01
To investigate the accuracy of defining characteristics of Situational low self-esteem we developed a cross-sectional study, with 52 pregnant women assisted in a family centre. The NANDA-I taxonomy was used as well as the Rosenberg's scale. The diagnosis was present in 32.7% of the sample and all characteristics presented statistical significance, except "Reports verbally situational challenge to its own value". The characteristics "Indecisive behavior" and "Helplessness expressions" had 82.35% of sensitivity. On the other hand, the characteristics "Expression of feelings of worthlessness" and "Reports verbally situational challenge to its own value" were the more specific, with 94.29% of specificity. These results can contribute with the nursing practice because the identification of accurate characteristics is essential to a secure inference.
Are 2 Questions Enough to Screen for Depression and Anxiety in Patients With Chronic Low Back Pain?
Lie, Stein Atle; Eriksen, Hege R.
2014-01-01
Study Design. Cross-sectional study. Objective. To examine the sensitivity of 2 single-item questions compared with 2 longer questionnaires for screening depression and anxiety among patients with chronic low back pain (CLBP). Summary of Background Data. Psychosocial factors are frequently identified as risk factors for developing CLBP and as predictors for treatment, and questionnaires are often used to screen for this. Shorter instruments may be easier to use in clinical practice settings. Methods. A total of 564 patients with 2 to 10 months of at least 50% sickness absence due to nonspecific low back pain were assessed for depression and anxiety with the Mini-International Neuropsychiatric Interview (MINI). Single-item questions for depression and anxiety from the Subjective Health Complaint Inventory and 2 longer questionnaires, the Hospital Anxiety and Depression Scale and Hopkins Symptom Checklist–25, were compared with MINI results, considered the “gold standard” in this study. Sensitivity and specificity of single-item and longer questionnaires and receiver operating characteristic curves were compared. Results. According to MINI, the prevalence of anxiety disorders was 12% whereas that of depressive disorders was 4%. The screening questions showed 95% sensitivity and 56% specificity for depressive disorders and 68% sensitivity and 85% specificity for anxiety disorders. The longer questionnaire, Hospital Anxiety and Depression Scale, showed 91% sensitivity and 85% specificity for depressive disorders and 58% sensitivity and 83% specificity for anxiety disorders. Hopkins Symptom Checklist–25 showed 86% sensitivity and 74% specificity for depressive disorders and 67% sensitivity and 87% specificity for anxiety disorders. For 3 of the anxiety disorders and 2 of the depressive disorders, a perfect sensitivity was found between the screening questions and MINI. Conclusions. A single-item screening question was sensitive for depression but less sensitive for anxiety. The screening questions further performed equal to 2 widely used questionnaires. Validation of these results in other populations and compared with other short-item screeners is needed. Level of Evidence: 3 PMID:24480946
Dou, Pan; Ju, Huiyan; Shang, Jing; Li, Xueying; Xue, Qing; Xu, Yang; Guo, Xiaohui
2016-08-24
There are various parameters to analyze obesity, however, no standard reference to predict, screen or diagnose PCOS with various obesity parameters has been established, and the accuracy of these parameters still needs to be studied.This study was to use the receiver operating characteristic (ROC) curve to explore the different values of three obesity parameters, body mass index (BMI), waist circumference (WC) and percentage of body fat (PBF) in the diagnosis of polycystic ovary syndrome (PCOS) in Chinese childbearing women. Three hundred patients who were diagnosed with PCOS at Center of Reproductive Medicine and Genetics of Peking University First Hospital were enrolled in this study, and 110 healthy age-matched women were enrolled as controls. The characteristics of BMI, WC and PBF in PCOS patients were analyzed. Compared with the control group, all the three obesity parameters were significantly increased in PCOS group. In terms of ROC area under the curve, WC > PBF > BMI, and they were all significantly different from those of the control. At a cut-off point of 80.5 cm, WC has a sensitivity of 73.6 % and a specificity of 85 % in diagnosis of PCOS; At a cut-off point of 29 %, PBF has a sensitivity of 88.2 % and a specificity of 57.7 % in diagnosis of PCOS; and at a cut-off point of 26.6 kg/m(2), BMI has a sensitivity of 54.5 % and a specificity of 98 % in diagnosis of PCOS. WC, BMI and PBF are valuable in screening and diagnosis of PCOS in Chinese childbearing women. PBF can be used to screen PCOS as it has a better sensitivity, while BMI can be used in the diagnosis of PCOS as it has a better specificity.
Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, William E.; Chi, Chen; Carney, Patricia A.; Taplin, Stephen H.; D’Orsi, Carl; Cutter, Gary; Hendrick, R. Edward; Elmore, Joann G.
2011-01-01
Background Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. Methods Screening mammograms (n = 469 512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. Results Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (≤1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001–2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001–2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. Conclusions We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance. PMID:15601640
Cherpanath, Thomas G V; Hirsch, Alexander; Geerts, Bart F; Lagrand, Wim K; Leeflang, Mariska M; Schultz, Marcus J; Groeneveld, A B Johan
2016-05-01
Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.
Taylor, Nicholas J.; Thomas, Nancy E.; Anton-Culver, Hoda; Armstrong, Bruce K.; Begg, Colin B.; Busam, Klaus J.; Cust, Anne E.; Dwyer, Terence; From, Lynn; Gallagher, Richard P.; Gruber, Stephen B.; Nishri, Diane E.; Orlow, Irene; Rosso, Stefano; Venn, Alison J.; Zanetti, Roberto; Berwick, Marianne; Kanetsky, Peter A.
2016-01-01
Although nevus count is an established risk factor for melanoma, relationships between nevus number and patient and tumor characteristics have not been well studied and the influence of nevus count on melanoma-specific survival is equivocal. Using data from the Genes, Environment, and Melanoma (GEM) study, a large population-based study of primary cutaneous melanoma, we evaluated associations between number of nevi and patient features, including sun-sensitivity summarized in a phenotypic index, and tumor characteristics, and we assessed the association of nevus count with melanoma-specific survival. Higher nevus counts were independently and positively associated with male gender and younger age at diagnosis and inversely associated with lentigo maligna histology. We observed a borderline significant trend of poorer melanoma-specific survival with increasing quartile of nevus count, but little or no association between number of nevi and pigmentary phenotypic characteristics or prognostic tumor features. PMID:27101944
Tousseyn, Simon; Dupont, Patrick; Goffin, Karolien; Sunaert, Stefan; Van Paesschen, Wim
2014-01-01
There is currently a lack of knowledge about electroencephalography (EEG)-functional magnetic resonance imaging (fMRI) specificity. Our aim was to define sensitivity and specificity of blood oxygen level dependent (BOLD) responses to interictal epileptic spikes during EEG-fMRI for detecting the ictal onset zone (IOZ). We studied 21 refractory focal epilepsy patients who had a well-defined IOZ after a full presurgical evaluation and interictal spikes during EEG-fMRI. Areas of spike-related BOLD changes overlapping the IOZ in patients were considered as true positives; if no overlap was found, they were treated as false-negatives. Matched healthy case-controls had undergone similar EEG-fMRI in order to determine true-negative and false-positive fractions. The spike-related regressor of the patient was used in the design matrix of the healthy case-control. Suprathreshold BOLD changes in the brain of controls were considered as false positives, absence of these changes as true negatives. Sensitivity and specificity were calculated for different statistical thresholds at the voxel level combined with different cluster size thresholds and represented in receiver operating characteristic (ROC)-curves. Additionally, we calculated the ROC-curves based on the cluster containing the maximal significant activation. We achieved a combination of 100% specificity and 62% sensitivity, using a Z-threshold in the interval 3.4–3.5 and cluster size threshold of 350 voxels. We could obtain higher sensitivity at the expense of specificity. Similar performance was found when using the cluster containing the maximal significant activation. Our data provide a guideline for different EEG-fMRI settings with their respective sensitivity and specificity for detecting the IOZ. The unique cluster containing the maximal significant BOLD activation was a sensitive and specific marker of the IOZ. PMID:25101049
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang Pengpeng; Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY; Wu, Leester
Purpose: To integrate imaging performance characteristics, specifically sensitivity and specificity, of magnetic resonance angiography (MRA) and digital subtraction angiography (DSA) into arteriovenous malformation (AVM) radiosurgery planning and evaluation. Methods and Materials: Images of 10 patients with AVMs located in critical brain areas were analyzed in this retrospective planning study. The image findings were first used to estimate the sensitivity and specificity of MRA and DSA. Instead of accepting the imaging observation as a binary (yes or no) mapping of AVM location, our alternative is to translate the image into an AVM probability distribution map by incorporating imagers' sensitivity and specificity,more » and to use this map as a basis for planning and evaluation. Three sets of radiosurgery plans, targeting the MRA and DSA positive overlap, MRA positive, and DSA positive were optimized for best conformality. The AVM obliteration rate (ORAVM) and brain complication rate served as endpoints for plan comparison. Results: In our 10-patient study, the specificities and sensitivities of MRA and DSA were estimated to be (0.95, 0.74) and (0.71, 0.95), respectively. The positive overlap of MRA and DSA accounted for 67.8% {+-} 4.9% of the estimated true AVM volume. Compared with plans targeting MRA and DSA-positive overlap, plans targeting MRA-positive or DSA-positive improved ORAVM by 4.1% {+-} 1.9% and 15.7% {+-} 8.3%, while also increasing the complication rate by 1.0% {+-} 0.8% and 4.4% {+-} 2.3%, respectively. Conclusions: The impact of imagers' quality should be quantified and incorporated in AVM radiosurgery planning and evaluation to facilitate clinical decision making.« less
Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas
2017-08-01
Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.
Grezina, N Iu; Suleĭmenova, G M
2011-01-01
The objective of the present study was to evaluate sensitivity and specificity of the HemDirect method on test-plates (Seratec) for detecting human hemoglobin (HHb). These characteristics were compared with those of other widely used methods designed for the detection of blood traces, viz. thin layer chromatography, hemotest, spectrofluorimetry, and identification of blood species specificity (by countercurrent immunoelectrophoresis in agar and on the acetate-cellulose film). It was shown that the HemDirect test is highly specific and far more sensitive than other techniques used for the same purpose in the practical work. It can be recommended as the method of choice for the detection of blood microtraces.
An enzyme-linked immunosorbent assay for detection of botulinum toxin-antibodies.
Dressler, Dirk; Gessler, Frank; Tacik, Pawel; Bigalke, Hans
2014-09-01
Antibodies against botulinum neurotoxin (BNT-AB) can be detected by the mouse protection assay (MPA), the hemidiaphragm assay (HDA), and by enzyme-linked immunosorbent assays (ELISA). Both MPA and HDA require sacrifice of experimental animals, and they are technically delicate and labor intensive. We introduce a specially developed ELISA for detection of BNT-A-AB and evaluate it against the HDA. Thirty serum samples were tested by HDA and by the new ELISA. Results were compared, and receiver operating characteristic analyses were used to optimize ELISA parameter constellation to obtain either maximal overall accuracy, maximal test sensitivity, or maximal test specificity. When the ELISA is optimized for sensitivity, a sensitivity of 100% and a specificity of 55% can be reached. When it is optimized for specificity, a specificity of 100% and a sensitivity of 90% can be obtained. We present an ELISA for BNT-AB detection that can be-for the first time-customized for special purposes. Adjusted for optimal sensitivity, it reaches the best sensitivity of all BNT-AB tests available. Using the new ELISA together with the HDA as a confirmation test allows testing for BNT-AB in large numbers of patients receiving BT drugs in an economical, fast, and more animal-friendly way. © 2014 International Parkinson and Movement Disorder Society.
ERIC Educational Resources Information Center
Hudziak, James J.; Althoff, Robert R.; Stanger, Catherine; van Beijsterveldt, C. E. M.; Nelson, Elliot C.; Hanna, Gregory L.; Boomsma, Dorret I.; Todd, Richard D.
2006-01-01
Background: The purpose of this study was to determine a score on the Obsessive Compulsive Scale (OCS) from the Child Behavior Checklist (CBCL) to screen for obsessive compulsive disorder (OCD) in children and to rigorously test the specificity and sensitivity of a single cutpoint. Methods: A receiver operating characteristic (ROC) curve analysis…
Silva, Richardson Augusto Rosendo da; Costa, Mayara Mirna do Nascimento; Souza, Vinicius Lino de; Silva, Bárbara Coeli Oliveira da; Costa, Cristiane da Silva; Andrade, Itaísa Fernandes Cardoso de
2017-10-30
to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied.
Role of androgen ratios in the prediction of the metabolic phenotype in polycystic ovary syndrome.
Minooee, Sonia; Ramezani Tehrani, Fahimeh; Tohidi, Maryam; Azizi, Fereidoun
2017-05-01
To identify the androgen ratio that best predicts insulin resistance and metabolic syndrome among women with polycystic ovary syndrome (PCOS). Data for 180 women with PCOS and 180 healthy controls were extracted from two previous studies in Iran (conducted during 2008-2010 and 2011-2013). The diagnosis of PCOS was based on the Rotterdam criteria. The serum concentration of different androgens was measured. Receiver operating characteristic curve analysis was used to assess the ability of various androgen ratios to predict insulin resistance and metabolic syndrome. Among women with PCOS, the testosterone-to-androstenedione ratio was the best predictor of insulin resistance (sensitivity 0.83, specificity 0.42) and metabolic syndrome (sensitivity 0.85, specificity 0.70). Among healthy controls, the ratio of free androgen index to testosterone was the best predictor of insulin resistance (sensitivity 0.84, specificity 0.33) and metabolic syndrome (sensitivity 0.91, specificity 0.17). The prediction of insulin resistance and metabolic syndrome among women with PCOS was best accomplished with the testosterone-to-androstenedione ratio. © 2017 International Federation of Gynecology and Obstetrics.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-02-20
We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Systematic review and meta-analysis. PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion.
The PHQ-PD as a Screening Tool for Panic Disorder in the Primary Care Setting in Spain
Wood, Cristina Mae; Ruíz-Rodríguez, Paloma; Tomás-Tomás, Patricia; Gracia-Gracia, Irene; Dongil-Collado, Esperanza; Iruarrizaga, M. Iciar
2016-01-01
Introduction Panic disorder is a common anxiety disorder and is highly prevalent in Spanish primary care centres. The use of validated tools can improve the detection of panic disorder in primary care populations, thus enabling referral for specialized treatment. The aim of this study is to determine the accuracy of the Patient Health Questionnaire-Panic Disorder (PHQ-PD) as a screening and diagnostic tool for panic disorder in Spanish primary care centres. Method We compared the psychometric properties of the PHQ-PD to the reference standard, the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview. General practitioners referred 178 patients who completed the entire PHQ test, including the PHQ-PD, to undergo the SCID-I. The sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios of the PHQ-PD were assessed. Results The operating characteristics of the PHQ-PD are moderate. The best cut-off score was 5 (sensitivity .77, specificity .72). Modifications to the questionnaire's algorithms improved test characteristics (sensitivity .77, specificity .72) compared to the original algorithm. The screening question alone yielded the highest sensitivity score (.83). Conclusion Although the modified algorithm of the PHQ-PD only yielded moderate results as a diagnostic test for panic disorder, it was better than the original. Using only the first question of the PHQ-PD showed the best psychometric properties (sensitivity). Based on these findings, we suggest the use of the screening questions for screening purposes and the modified algorithm for diagnostic purposes. PMID:27525977
Optical Fibers Would Sense Local Strains
NASA Technical Reports Server (NTRS)
Egalon, Claudio O.; Rogowski, Robert S.
1994-01-01
Proposed fiber-optic transducers measure local strains. Includes lead-in and lead-out lengths producing no changes in phase shifts, plus short sensing length in which phase shift is sensitive to strain. Phase shifts in single-mode fibers vary with strains. In alternative version, multiple portions of optical fiber sensitive to strains characteristic of specific vibrational mode of object. Same principle also used with two-mode fiber.
Chen, Qinghua; Raghavan, Prashant; Mukherjee, Sugoto; Jameson, Mark J; Patrie, James; Xin, Wenjun; Xian, Junfang; Wang, Zhenchang; Levine, Paul A; Wintermark, Max
2015-10-01
The aim of this study was to systematically compare a comprehensive array of magnetic resonance (MR) imaging features in terms of their sensitivity and specificity to diagnose cervical lymph node metastases in patients with thyroid cancer. The study included 41 patients with thyroid malignancy who underwent surgical excision of cervical lymph nodes and had preoperative MR imaging ≤4weeks prior to surgery. Three head and neck neuroradiologists independently evaluated all the MR images. Using the pathology results as reference, the sensitivity, specificity and interobserver agreement of each MR imaging characteristic were calculated. On multivariate analysis, no single imaging feature was significantly correlated with metastasis. In general, imaging features demonstrated high specificity, but poor sensitivity and moderate interobserver agreement at best. Commonly used MR imaging features have limited sensitivity at correctly identifying cervical lymph node metastases in patients with thyroid cancer. A negative neck MR scan should not dissuade a surgeon from performing a neck dissection in patients with thyroid carcinomas.
Limitations of available tests for diagnosis of infectious mononucleosis.
Fleisher, G R; Collins, M; Fager, S
1983-04-01
Among 500 students seen at a university health service for illnesses resembling infectious mononucleosis (IM), the diagnosis of IM was established in 124 (25%) on the basis of the initial presence or subsequent emergence of the spectrum of Epstein-Barr virus (EBV) antibodies characteristic of a primary EBV infection. Of these 124 patients, 113 had an EBV-specific antibody pattern in the initial serum indicative of current primary infection; however, 11 (9%) had no detectable immunoglobulin G antibodies to EBV-specific antigens in their first serum. The sensitivity of this panel of EBV antibody assays was 91% and the specificity was 100%. Initial sera had detectable heterophil antibodies for 107 (86%) of the 124 students with IM and for 2 with other illnesses. Among our patients, the Monospot (Ortho Diagnostics Inc.) test had a sensitivity of 86% and a specificity of 99%. Reliance on hematological criteria (lymphocyte count greater than or equal to 50% and atypical lymphocyte count greater than or equal to 10%) gave a sensitivity of only 39%, but a specificity of 99%. Students with IM who showed a delayed emergence of the spectrum of EBV-specific antibodies characteristic of an acute infection were compared with control patients who had such antibodies at the time of their initial visit to the health service. They were found to have a briefer duration of illness (P greater than 0.05), lower leukocyte (P less than 0.005), lymphocyte (P less than 0.005), and atypical lymphocyte (P less than 0.05) counts, and a less frequent occurrence of heterophil antibodies (P less than 0.05).
ERIC Educational Resources Information Center
Yarbay Duman, Tuba; Topbas, Seyhun
2016-01-01
Background: Impairments in tense morphology are characteristic of English-speaking children with specific language impairment (SLI). Recent studies have investigated the role that aspect plays in the difficulties found in tense morphology. It has been suggested that children with SLI are less sensitive to aspect and its interaction with tense than…
Graves, Gabrielle S; Adam, Murtaza K; Stepien, Kimberly E; Han, Dennis P
2014-08-01
To evaluate sensitivity, specificity and reproducibility of colour difference plot analysis (CDPA) of 103 hexagon multifocal electroretinogram (mfERG) in detecting established hydroxychloroquine (HCQ) retinal toxicity. Twenty-three patients taking HCQ were divided into those with and without retinal toxicity and were compared with a control group without retinal disease and not taking HCQ. CDPA with two masked examiners was performed using age-corrected mfERG responses in the central ring (Rc ; 0-5.5 degrees from fixation) and paracentral ring (Rp ; 5.5-11 degrees from fixation). An abnormal ring was defined as containing any hexagons with a difference in two or more standard deviations from normal (colour blue or black). Categorical analysis (ring involvement or not) showed Rc had 83% sensitivity and 93% specificity. Rp had 89% sensitivity and 82% specificity. Requiring abnormal hexagons in both Rc and Rp yielded sensitivity and specificity of 83% and 95%, respectively. If required in only one ring, they were 89% and 80%, respectively. In this population, there was complete agreement in identifying toxicity when comparing CDPA using Rp with ring ratio analysis using R5/R4 P1 ring responses (89% sensitivity and 95% specificity). Continuous analysis of CDPA with receiver operating characteristic analysis showed optimized detection (83% sensitivity and 96% specificity) when ≥4 abnormal hexagons were present anywhere within the Rp ring outline. Intergrader agreement and reproducibility were good. Colour difference plot analysis had sensitivity and specificity that approached that of ring ratio analysis of R5/R4 P₁ responses. Ease of implementation and reproducibility are notable advantages of CDPA. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Population and High-Risk Group Screening for Glaucoma: The Los Angeles Latino Eye Study
Francis, Brian A.; Vigen, Cheryl; Lai, Mei-Ying; Winarko, Jonathan; Nguyen, Betsy; Azen, Stanley
2011-01-01
Purpose. To evaluate the ability of various screening tests, both individually and in combination, to detect glaucoma in the general Latino population and high-risk subgroups. Methods. The Los Angeles Latino Eye Study is a population-based study of eye disease in Latinos 40 years of age and older. Participants (n = 6082) underwent Humphrey visual field testing (HVF), frequency doubling technology (FDT) perimetry, measurement of intraocular pressure (IOP) and central corneal thickness (CCT), and independent assessment of optic nerve vertical cup disc (C/D) ratio. Screening parameters were evaluated for three definitions of glaucoma based on optic disc, visual field, and a combination of both. Analyses were also conducted for high-risk subgroups (family history of glaucoma, diabetes mellitus, and age ≥65 years). Sensitivity, specificity, and receiver operating characteristic curves were calculated for those continuous parameters independently associated with glaucoma. Classification and regression tree (CART) analysis was used to develop a multivariate algorithm for glaucoma screening. Results. Preset cutoffs for screening parameters yielded a generally poor balance of sensitivity and specificity (sensitivity/specificity for IOP ≥21 mm Hg and C/D ≥0.8 was 0.24/0.97 and 0.60/0.98, respectively). Assessment of high-risk subgroups did not improve the sensitivity/specificity of individual screening parameters. A CART analysis using multiple screening parameters—C/D, HVF, and IOP—substantially improved the balance of sensitivity and specificity (sensitivity/specificity 0.92/0.92). Conclusions. No single screening parameter is useful for glaucoma screening. However, a combination of vertical C/D ratio, HVF, and IOP provides the best balance of sensitivity/specificity and is likely to provide the highest yield in glaucoma screening programs. PMID:21245400
Banal, F; Dougados, M; Combescure, C; Gossec, L
2009-07-01
To evaluate the ability of the widely used ACR set of criteria (both list and tree format) to diagnose RA compared with expert opinion according to disease duration. A systematic literature review was conducted in PubMed and Embase databases. All articles reporting the prevalence of RA according to ACR criteria and expert opinion in cohorts of early (<1 year duration) or established (>1 year) arthritis were analysed to calculate the sensitivity and specificity of ACR 1987 criteria against the "gold standard" (expert opinion). A meta-analysis using a summary receiver operating characteristic (SROC) curve was performed and pooled sensitivity and specificity were calculated with confidence intervals. Of 138 publications initially identified, 19 were analysable (total 7438 patients, 3883 RA). In early arthritis, pooled sensitivity and specificity of the ACR set of criteria were 77% (68% to 84%) and 77% (68% to 84%) in the list format versus 80% (72% to 88%) and 33% (24% to 43%) in the tree format. In established arthritis, sensitivity and specificity were respectively 79% (71% to 85%) and 90% (84% to 94%) versus 80% (71% to 85%) and 93% (86% to 97%). The SROC meta-analysis confirmed the statistically significant differences, suggesting that diagnostic performances of ACR list criteria are better in established arthritis. The specificity of ACR 1987 criteria in early RA is low, and these criteria should not be used as diagnostic tools. Sensitivity and specificity in established RA are higher, which reflects their use as classification criteria gold standard.
Le Strat, Yann
2017-01-01
The objective of this paper is to evaluate a panel of statistical algorithms for temporal outbreak detection. Based on a large dataset of simulated weekly surveillance time series, we performed a systematic assessment of 21 statistical algorithms, 19 implemented in the R package surveillance and two other methods. We estimated false positive rate (FPR), probability of detection (POD), probability of detection during the first week, sensitivity, specificity, negative and positive predictive values and F1-measure for each detection method. Then, to identify the factors associated with these performance measures, we ran multivariate Poisson regression models adjusted for the characteristics of the simulated time series (trend, seasonality, dispersion, outbreak sizes, etc.). The FPR ranged from 0.7% to 59.9% and the POD from 43.3% to 88.7%. Some methods had a very high specificity, up to 99.4%, but a low sensitivity. Methods with a high sensitivity (up to 79.5%) had a low specificity. All methods had a high negative predictive value, over 94%, while positive predictive values ranged from 6.5% to 68.4%. Multivariate Poisson regression models showed that performance measures were strongly influenced by the characteristics of time series. Past or current outbreak size and duration strongly influenced detection performances. PMID:28715489
Mechanisms of gender-related outcome differences after carotid endarterectomy.
den Hartog, Anne G; Algra, Ale; Moll, Frans L; de Borst, Gert J
2010-10-01
Large randomized trials have confirmed a difference in outcome after carotid endarterectomy (CEA) between men and women. In this review, we aimed to provide an overview of the gender-specific characteristics causing these perioperative and long-term outcome differences between men and women after CEA. A systematic search strategy with the synonyms of 'gender' and 'carotid endarterectomy' was conducted from PubMed and EMBASE databases. Only 11 relevant studies specifically discussing gender-specific related characteristics and their influence on outcome after CEA could be identified. Due to the limited number of included studies, pooling of findings was impossible, and results are presented in a descriptive manner. Each included study described only one possible gender-specific factor. Differences in carotid artery diameter, sex hormones, sensitivity for antiplatelet therapy, plaque morphology, occurrence of microembolic signals, and restenosis rate have all been suggested as gender-specific characteristics influencing outcome after CEA. Higher embolic potential in women and relatively stable female plaque morphology are the best-described factors influencing the difference in outcomes between men and women. However, the overall evidence for outcome differences by gender-specific characteristics in the literature is limited. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
ERIC Educational Resources Information Center
Bredemeier, Keith; Spielberg, Jeffery M.; Silton, Rebecca Levin; Berenbaum, Howard; Heller, Wendy; Miller, Gregory A.
2010-01-01
The present study examined the utility of the anhedonic depression scale from the Mood and Anxiety Symptoms Questionnaire (MASQ-AD scale) as a way to screen for depressive disorders. Using receiver-operating characteristic analysis, we examined the sensitivity and specificity of the full 22-item MASQ-AD scale, as well as the 8- and 14-item…
Development of a Pediatric Ebola Predictive Score, Sierra Leone1.
Fitzgerald, Felicity; Wing, Kevin; Naveed, Asad; Gbessay, Musa; Ross, J C G; Checchi, Francesco; Youkee, Daniel; Jalloh, Mohamed Boie; Baion, David E; Mustapha, Ayeshatu; Jah, Hawanatu; Lako, Sandra; Oza, Shefali; Boufkhed, Sabah; Feury, Reynold; Bielicki, Julia; Williamson, Elizabeth; Gibb, Diana M; Klein, Nigel; Sahr, Foday; Yeung, Shunmay
2018-02-01
We compared children who were positive for Ebola virus disease (EVD) with those who were negative to derive a pediatric EVD predictor (PEP) score. We collected data on all children <13 years of age admitted to 11 Ebola holding units in Sierra Leone during August 2014-March 2015 and performed multivariable logistic regression. Among 1,054 children, 309 (29%) were EVD positive and 697 (66%) EVD negative, with 48 (5%) missing. Contact history, conjunctivitis, and age were the strongest positive predictors for EVD. The PEP score had an area under receiver operating characteristics curve of 0.80. A PEP score of 7/10 was 92% specific and 44% sensitive; 3/10 was 30% specific, 94% sensitive. The PEP score could correctly classify 79%-90% of children and could be used to facilitate triage into risk categories, depending on the sensitivity or specificity required.
Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, Young Kee; Lee, Jeong Hyun
2017-04-01
An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.
Assing, K; Nielsen, C H; Poulsen, L K
2006-03-01
Asymptomatic skin sensitization (AS) has been shown to be a risk factor for respiratory allergic disease. We investigated allergen and recall antigen-driven T cell proliferation, cytokine production and T cell expression of the chemokine receptor CCR4, in cultures derived from symptomatic atopics (SA), subjects with AS and healthy controls (HC). Numbers of allergen-specific precursor T cells in all three groups were also estimated. Peripheral blood mononuclear cells from the three groups were isolated and stimulated with allergen and tetanus toxoid. Proliferation, cytokine production and CCR4 expression were measured by flow cytometry. A significantly increased proportion of CD4(+) memory T cells proliferated in response to allergen in SA as compared with subjects with AS (P<0.001) and HC (P<0.001). Only in SA was expansion of CD4(+)CCR4(+) T cells, after allergen stimulation observed. SA had higher frequencies of allergen-specific T cells than subjects with AS and HC (P=0.02, for both). With regard to allergen-induced production of T-helper type 1 (Th1) and Th2 cytokines, subjects with AS and HC resembled each other, while differing significantly from SA. We conclude, that subjects with AS, although clearly IgE sensitized, have significant diminished numbers of allergen-specific T cells as well as decreased allergen-induced CD4(+) memory T cell proliferation as compared with SA. To a large extent, our findings are capable of explaining the immunological characteristics associated with AS. Our findings may serve as better prognostic markers for subsequent allergic progression, than previously described clinical and paraclinical characteristics.
Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.
2013-01-01
No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.
Lovallo, Carmela; Rolandi, Stefano; Rossetti, Anna Maria; Lusignani, Maura
2010-03-01
This paper is a report of a study comparing the effectiveness of two falls risk assessment tools (Conley Scale and Hendrich Risk Model) by using them simultaneously with the same sample of hospital inpatients. Different risk assessment tools are available in literature. However, neither recent critical reviews nor international guidelines on fall prevention have identified tools that can be generalized to all categories of hospitalized patients. A prospective observational study was carried out in acute medical, surgical wards and rehabilitation units. From October 2007 to January 2008, 1148 patients were assessed with both instruments, subsequently noting the occurrence of falls. The sensitivity, specificity, positive and negative predictive values, and Receiver Operating Characteristics curves were calculated. The number of patients correctly identified with the Conley Scale (n = 41) was higher than with the Hendrich Model (n = 27). The Conley Scale gave sensitivity and specificity values of 69.49% and 61% respectively. The Hendrich Model gave a sensitivity value of 45.76% and a specificity value of 71%. Positive and negative predictive values were comparable. The Conley Scale is indicated for use in the medical sector, on the strength of its high sensitivity. However, since its specificity is very low, it is deemed useful to submit individual patients giving positive results to more in-depth clinical evaluation in order to decide whether preventive measures need to be taken. In surgical sectors, the low sensitivity values given by both scales suggest that further studies are warranted.
Fernando, Shannon M; Tran, Alexandre; Cheng, Wei; Rochwerg, Bram; Kyeremanteng, Kwadwo; Seely, Andrew J E; Inaba, Kenji; Perry, Jeffrey J
2018-04-18
We sought to summarize accuracy of physical examination, imaging, and Laboratory Risk Indicator for Necrotizing Fasciitis (LRINEC) score in diagnosis of necrotizing soft tissue infection (NSTI) in adults with a soft tissue infection clinically concerning for NSTI. NSTI is a life-threatening diagnosis. Delay to diagnosis and surgical management is associated with increased mortality. We searched 6 databases from inception through November 2017. We included English-language studies reporting diagnostic accuracy of testing or LRINEC Score. Outcome was NSTI confirmed by surgery or histopathology. Two reviewers screened all citations and extracted data independently. Summary measures were obtained from the Hierarchical Summary Receiver Operating Characteristic model. From 2,290 citations, we included 23 studies (n = 5982). Of physical examination signs, pooled sensitivity and specificity for fever was 46.0% and 77.0% respectively, for hemorrhagic bullae 25.2% and 95.8%, and for hypotension 21.0% and 97.7%. Computed tomography (CT) had sensitivity of 88.5% and specificity of 93.3%, while plain radiography had sensitivity of 48.9% and specificity of 94.0%. Finally, LRINEC ≥ 6 had sensitivity of 68.2% and specificity of 84.8%, while LRINEC ≥ 8 had sensitivity of 40.8% and specificity of 94.9%. Absence of any 1 physical examination feature (eg, fever or hypotension) is not sufficient to rule-out NSTI. CT is superior to plain radiography. LRINEC had poor sensitivity, and should not be used to rule-out NSTI. Given the poor sensitivity of these tests, a high clinical suspicion warrants early surgical consultation for definitive diagnosis and management.
Validity, sensitivity and specificity of the mentation, behavior and mood subscale of the UPDRS.
Holroyd, Suzanne; Currie, Lillian J; Wooten, G Frederick
2008-06-01
The unified Parkinson's disease rating scale (UPDRS) is the most widely used tool to rate the severity and the stage of Parkinson's disease (PD). However, the mentation, behavior and mood (MBM) subscale of the UPDRS has received little investigation regarding its validity and sensitivity. Three items of this subscale were compared to criterion tests to examine validity, sensitivity and specificity. Ninety-seven patients with idiopathic PD were assessed on the UPDRS. Scores on three items of the MBM subscale, intellectual impairment, thought disorder and depression, were compared to criterion tests, the telephone interview for cognition status (TICS), psychiatric assessment for psychosis and the geriatric depression scale (GDS). Non-parametric tests of association were performed to examine concurrent validity of the MBM items. The sensitivities, specificities and optimal cutoff scores for each MBM item were estimated by receiver operating characteristic (ROC) curve analysis. The MBM items demonstrated low to moderate correlation with the criterion tests, and the sensitivity and specificity were not strong. Even using a score of 7.0 on the items of the MBM demonstrated a sensitivity/specificity of only 0.19/0.48 for intellectual impairment, 0.60/0.72 for thought disorder and 0.61/0.87 for depression. Using a more appropriate cutoff of 2.0 revealed sensitivities of 0.01, 0.38 and 0.13 respectively. The MBM subscale items of intellectual impairment, thought disorder and depression are not appropriate for screening or diagnostic purposes. Tools such as the TICS and the GDS should be considered instead.
ROC-ing along: Evaluation and interpretation of receiver operating characteristic curves.
Carter, Jane V; Pan, Jianmin; Rai, Shesh N; Galandiuk, Susan
2016-06-01
It is vital for clinicians to understand and interpret correctly medical statistics as used in clinical studies. In this review, we address current issues and focus on delivering a simple, yet comprehensive, explanation of common research methodology involving receiver operating characteristic (ROC) curves. ROC curves are used most commonly in medicine as a means of evaluating diagnostic tests. Sample data from a plasma test for the diagnosis of colorectal cancer were used to generate a prediction model. These are actual, unpublished data that have been used to describe the calculation of sensitivity, specificity, positive predictive and negative predictive values, and accuracy. The ROC curves were generated to determine the accuracy of this plasma test. These curves are generated by plotting the sensitivity (true-positive rate) on the y axis and 1 - specificity (false-positive rate) on the x axis. Curves that approach closest to the coordinate (x = 0, y = 1) are more highly predictive, whereas ROC curves that lie close to the line of equality indicate that the result is no better than that obtained by chance. The optimum sensitivity and specificity can be determined from the graph as the point where the minimum distance line crosses the ROC curve. This point corresponds to the Youden index (J), a function of sensitivity and specificity used commonly to rate diagnostic tests. The area under the curve is used to quantify the overall ability of a test to discriminate between 2 outcomes. By following these simple guidelines, interpretation of ROC curves will be less difficult and they can then be interpreted more reliably when writing, reviewing, or analyzing scientific papers. Copyright © 2016 Elsevier Inc. All rights reserved.
Fujita, Takaaki; Sato, Atsushi; Tsuchiya, Kenji; Ohashi, Takuro; Yamane, Kazuhiro; Yamamoto, Yuichi; Iokawa, Kazuaki; Ohira, Yoko; Otsuki, Koji; Tozato, Fusae
2017-12-01
This study aimed to elucidate the relationship between grooming performance of stroke patients and various motor and cognitive functions and to examine the cognitive and physical functional standards required for grooming independence. We retrospectively analyzed the data of 96 hospitalized patients with first stroke in a rehabilitation hospital ward. Logistic regression analysis and receiver operating characteristic curves were used to investigate the related cognitive and motor functions with grooming performance and to calculate the cutoff values for independence and supervision levels in grooming. For analysis between the independent and supervision-dependent groups, the only item with an area under the curve (AUC) of .9 or higher was the Berg Balance Scale, and the calculated cutoff value was 41/40 (sensitivity, 83.6%; specificity, 87.8%). For analysis between the independent-supervision and dependent groups, the items with an AUC of .9 or higher were the Simple Test for Evaluating Hand Function (STEF) on the nonaffected side, Vitality Index (VI), and FIM ® cognition. The cutoff values were 68/67 for the STEF (sensitivity, 100%; specificity, 72.2%), 9/8 points for the VI (sensitivity, 92.3%; specificity, 88.9%), and 23/22 points for FIM ® cognition (sensitivity, 91.0%; specificity, 88.9%). Our results suggest that upper-extremity functions on the nonaffected side, motivation, and cognitive functions are particularly important to achieve the supervision level and that balance is important to reach the independence level. The effective improvement of grooming performance is possible by performing therapeutic or compensatory intervention on functions that have not achieved these cutoff values. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Liu, Bo-Ji; Li, Dan-Dan; Xu, Hui-Xiong; Guo, Le-Hang; Zhang, Yi-Feng; Xu, Jun-Mei; Liu, Chang; Liu, Lin-Na; Li, Xiao-Long; Xu, Xiao-Hong; Qu, Shen; Xing, Mingzhao
2015-12-01
The aim of this study was to evaluate the diagnostic performance of quantitative shear wave velocity (SWV) measurement on acoustic radiation force impulse (ARFI) elastography for differentiation between benign and malignant thyroid nodules using meta-analysis. The databases of PubMed and the Web of Science were searched. Studies published in English on assessment of the sensitivity and specificity of ARFI elastography for the differentiation of thyroid nodules were collected. The quantitative measurement of ARFI elastography was evaluated by SWV (m/s). Meta-Disc Version 1.4 software was used to describe and calculate the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio and summary receiver operating characteristic curves. We analyzed a total of 13 studies, which included 1,854 thyroid nodules (including 1,339 benign nodules and 515 malignant nodules) from 1,641 patients. The summary sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules by SWV were 0.81 (95% confidence interval [CI]: 0.77-0.84) and 0.84 (95% CI: 0.81-0.86), respectively. The pooled positive and negative likelihood ratios were 5.21 (95% CI: 3.56-7.62) and 0.23 (95% CI: 0.17-0.32), respectively. The pooled diagnostic odds ratio was 27.53 (95% CI: 14.58-52.01), and the area under the summary receiver operating characteristic curve was 0.91 (Q* = 0.84). In conclusion, SWV measurement on ARFI elastography has high sensitivity and specificity for differential diagnosis between benign and malignant thyroid nodules and can be used in combination with conventional ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Use of point-of-care ultrasound in long bone fractures: a systematic review and meta-analysis.
Chartier, Lucas B; Bosco, Laura; Lapointe-Shaw, Lauren; Chenkin, Jordan
2017-03-01
Long bone fractures (LBFs) are among the most frequent traumatic injuries seen in emergency departments. Reduction and immobilization is the most common form of treatment for displaced fractures. Point-of-care ultrasound (PoCUS) is a promising technique for diagnosing LBFs and assessing the success of reduction attempts. This article offers a comprehensive review of the use of PoCUS for the diagnosis and reduction of LBFs. Data source MEDLINE and EMBASE databases were searched through July 19, 2015. Study selection We included prospective studies that assessed test characteristics of PoCUS in 1) the diagnosis or 2) the reduction of LBFs. The methodological quality of the included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data extraction Thirty studies met inclusion criteria (n=3,506; overall fracture rate 48.0%). Test characteristics of PoCUS for the diagnosis of LBFs were as follows: sensitivity 64.7%-100%, specificity 79.2%-100%, positive likelihood ratio (LR) 3.11-infinity, and negative LR zero-0.45. Sensitivity and specificity for the adequate reduction of LBFs with PoCUS were 94%-100% and 56%-100%, respectively. PoCUS diagnosis of pediatric forearm fractures in 10 studies showed a pooled sensitivity of 93.1% (95% confidence interval [CI], 87.2%-96.4%) and specificity of 92.9% (95% CI, 86.6%-96.4%), and PoCUS diagnosis of adult ankle fractures in four studies showed a pooled sensitivity of 89.5% (95% CI, 77.0%-95.6%) and specificity of 94.2% (95% CI, 86.1%-97.7%). PoCUS demonstrates good diagnostic accuracy in all LBFs studied, especially in pooled results of diagnosis of pediatric forearm and adult ankle fractures. PoCUS is an appropriate adjunct to plain radiographs for LBFs.
Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi
2008-07-01
To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.
Choe, Young June; Hu, Jae Kyung; Song, Kyung Min; Cho, Heeyeon; Yoon, Hee Sook; Kim, Seung Tae; Lee, Han Jung; Kim, Kisoon; Bae, Geun-Ryang; Lee, Jong-Koo
2012-01-01
In this study, we have described the clinical characteristics of vaccine-modified measles to assess the performance of an expanded case definition in a school outbreak that occurred in 2010. The sensitivity, specificity, and the positive and negative predictive values were evaluated. Among 74 cases of vaccine-modified measles, 47 (64%) met the original case definition. Fever and rash were observed in 73% (54/74); fever was the most common (96%, 71/74) presenting symptom, and rash was noted in 77% (57/74) of the cases. The original case definition showed an overall sensitivity of 63.5% and a specificity of 100.0%. The expanded case definition combining fever and rash showed a higher sensitivity (72.9%) but a lower specificity (88.2%) than the original. The presence of fever and one or more of cough, coryza, or conjunctivitis scored the highest sensitivity among the combinations of signs and symptoms (77.0%), but scored the lowest specificity (52.9%). The expanded case definition was sensitive in identifying suspected cases of vaccine-modified measles. We suggest using this expanded definition for outbreak investigation in a closed community, and consider further discussions on expanding the case definition of measles for routine surveillance in South Korea.
Electromagnetic and nuclear radiation detector using micromechanical sensors
Thundat, Thomas G.; Warmack, Robert J.; Wachter, Eric A.
2000-01-01
Electromagnetic and nuclear radiation is detected by micromechanical sensors that can be coated with various interactive materials. As the micromechanical sensors absorb radiation, the sensors bend and/or undergo a shift in resonance characteristics. The bending and resonance changes are detected with high sensitivity by any of several detection methods including optical, capacitive, and piezoresistive methods. Wide bands of the electromagnetic spectrum can be imaged with picoJoule sensitivity, and specific absorptive coatings can be used for selective sensitivity in specific wavelength bands. Microcantilevers coated with optical cross-linking polymers are useful as integrating optical radiation dosimeters. Nuclear radiation dosimetry is possible by fabricating cantilevers from materials that are sensitive to various nuclear particles or radiation. Upon exposure to radiation, the cantilever bends due to stress and its resonance frequency shifts due to changes in elastic properties, based on cantilever shape and properties of the coating.
Yo, Chia-Hung; Lee, Si-Huei; Chang, Shy-Shin; Lee, Matthew Chien-Hung; Lee, Chien-Chang
2014-01-01
Objectives We performed a systematic review and meta-analysis of studies on high-sensitivity C-reactive protein (hs-CRP) assays to see whether these tests are predictive of atrial fibrillation (AF) recurrence after cardioversion. Design Systematic review and meta-analysis. Data sources PubMed, EMBASE and Cochrane databases as well as a hand search of the reference lists in the retrieved articles from inception to December 2013. Study eligibility criteria This review selected observational studies in which the measurements of serum CRP were used to predict AF recurrence. An hs-CRP assay was defined as any CRP test capable of measuring serum CRP to below 0.6 mg/dL. Primary and secondary outcome measures We summarised test performance characteristics with the use of forest plots, hierarchical summary receiver operating characteristic curves and bivariate random effects models. Meta-regression analysis was performed to explore the source of heterogeneity. Results We included nine qualifying studies comprising a total of 347 patients with AF recurrence and 335 controls. A CRP level higher than the optimal cut-off point was an independent predictor of AF recurrence after cardioversion (summary adjusted OR: 3.33; 95% CI 2.10 to 5.28). The estimated pooled sensitivity and specificity for hs-CRP was 71.0% (95% CI 63% to 78%) and 72.0% (61% to 81%), respectively. Most studies used a CRP cut-off point of 1.9 mg/L to predict long-term AF recurrence (77% sensitivity, 65% specificity), and 3 mg/L to predict short-term AF recurrence (73% sensitivity, 71% specificity). Conclusions hs-CRP assays are moderately accurate in predicting AF recurrence after successful cardioversion. PMID:24556243
Raji, Cyrus A; Willeumier, Kristen; Taylor, Derek; Tarzwell, Robert; Newberg, Andrew; Henderson, Theodore A; Amen, Daniel G
2015-09-01
PTSD and TBI are two common conditions in veteran populations that can be difficult to distinguish clinically. The default mode network (DMN) is abnormal in a multitude of neurological and psychiatric disorders. We hypothesize that brain perfusion SPECT can be applied to diagnostically separate PTSD from TBI reliably in a veteran cohort using DMN regions. A group of 196 veterans (36 with PTSD, 115 with TBI, 45 with PTSD/TBI) were selected from a large multi-site population cohort of individuals with psychiatric disease. Inclusion criteria were peacetime or wartime veterans regardless of branch of service and included those for whom the traumatic brain injury was not service related. SPECT imaging was performed on this group both at rest and during a concentration task. These measures, as well as the baseline-concentration difference, were then inputted from DMN regions into separate binary logistic regression models controlling for age, gender, race, clinic site, co-morbid psychiatric diseases, TBI severity, whether or not the TBI was service related, and branch of armed service. Predicted probabilities were then inputted into a receiver operating characteristic analysis to compute sensitivity, specificity, and accuracy. Compared to PSTD, persons with TBI were older, male, and had higher rates of bipolar and major depressive disorder (p < 0.05). Baseline quantitative regions with SPECT separated PTSD from TBI in the veterans with 92 % sensitivity, 85 % specificity, and 94 % accuracy. With concentration scans, there was 85 % sensitivity, 83 % specificity and 89 % accuracy. Baseline-concentration (the difference metric between the two scans) scans were 85 % sensitivity, 80 % specificity, and 87 % accuracy. In separating TBI from PTSD/TBI visual readings of baseline scans had 85 % sensitivity, 81 % specificity, and 83 % accuracy. Concentration scans had 80 % sensitivity, 65 % specificity, and 79 % accuracy. Baseline-concentration scans had 82 % sensitivity, 69 % specificity, and 81 % accuracy. For separating PTSD from PTSD/TBI baseline scans had 87 % sensitivity, 83 % specificity, and 92 % accuracy. Concentration scans had 91 % sensitivity, 76 % specificity, and 88 % accuracy. Baseline-concentration scans had 84 % sensitivity, 64 % specificity, and 85 % accuracy. This study demonstrates the ability to separate PTSD and TBI from each other in a veteran population using functional neuroimaging.
Madžar, Zrinko; Kopljar, Mario; Madžar, Tomislav; Mesić, Marko; Mužina Mišić, Dubravka; Čiček, Slaven; Zovak, Mario
2016-12-01
The aim of the study was to assess diagnostic accuracy (sensitivity and specificity) of Fenyö-Lindberg and Teicher scores for distinguishing patients that need immediate surgical treatment from the others, in a female population from an urban setting. The study prospectively included 130 female patients admitted to the emergency department with abdominal pain indicating acute appendicitis. The scores and parameters of validity were calculated and compared to definitive diagnosis. For Fenyö-Lindberg score of -17 or less, 84.5% sensitivity, 55.6% specificity, 87.9% positive predictive value (PPV) and 48.4% negative predictive value (NPV) were recorded. For cut-off value greater or equal to -2, there was 59.2% sensitivity, 77.8% specificity, 91% PPV and 33.3% NPV. The Receiver Operating Characteristic (ROC) curve analysis of Fenyö-Lindberg score showed that the best single cut-off value for discriminating acute appendicitis in the study population was -15. For Teicher score, values greater than -3 yielded 89.3% sensitivity and 22.2% specificity, 81.4% PPV and 35.3% NPV. In conclusion, Fenyö-Lindberg score could be used as an additional tool to exclude appendicitis and avoid unnecessary appendectomies. Teicher score may help in recognizing patients with appendicitis. None of the two scores can indicate or decline appendectomy in all cases. Scoring systems may be useful for pointing to important clinical signs and symptoms in specific subpopulations.
Proteomic Approach for Diagnostic Applications in Head and Neck Cancer — EDRN Public Portal
To evaluate the test characteristics of a panel of biomarkers for identifying patients with early stage head and neck squamous cell carcinoma (HNSCC). The primary endpoints are sensitivity, specificity and accuracy of the marker panel. This study of the test characteristics of a modeling strategy for diagnosing HNSCC uses a case-control design, with several types of cases and several types of controls.
da Silva, Richardson Augusto Rosendo; Costa, Mayara Mirna do Nascimento; de Souza, Vinicius Lino; da Silva, Bárbara Coeli Oliveira; Costa, Cristiane da Silva; de Andrade, Itaísa Fernandes Cardoso
2017-01-01
ABSTRACT Objective: to evaluate the accuracy of the defining characteristics of the NANDA International nursing diagnosis, noncompliance, in people with HIV. Method: study of diagnostic accuracy, performed in two stages. In the first stage, 113 people with HIV from a hospital of infectious diseases in the Northeast of Brazil were assessed for identification of clinical indicators of noncompliance. In the second, the defining characteristics were evaluated by six specialist nurses, analyzing the presence or absence of the diagnosis. For accuracy of the clinical indicators, the specificity, sensitivity, predictive values and likelihood ratios were measured. Results: the presence of the noncompliance diagnosis was shown in 69% (n=78) of people with HIV. The most sensitive indicator was, missing of appointments (OR: 28.93, 95% CI: 1.112-2.126, p = 0.002). On the other hand, nonadherence behavior (OR: 15.00, 95% CI: 1.829-3.981, p = 0.001) and failure to meet outcomes (OR: 13.41; 95% CI: 1.272-2.508; P = 0.003) achieved higher specificity. Conclusion: the most accurate defining characteristics were nonadherence behavior, missing of appointments, and failure to meet outcomes. Thus, in the presence of these, the nurse can identify, with greater security, the diagnosis studied. PMID:29091125
Brief assessment of food insecurity accurately identifies high-risk US adults.
Gundersen, Craig; Engelhard, Emily E; Crumbaugh, Amy S; Seligman, Hilary K
2017-06-01
To facilitate the introduction of food insecurity screening into clinical settings, we examined the test performance of two-item screening questions for food insecurity against the US Department of Agriculture's Core Food Security Module. We examined sensitivity, specificity and accuracy of various two-item combinations of questions assessing food insecurity in the general population and high-risk population subgroups. 2013 Current Population Survey December Supplement, a population-based US survey. All survey participants from the general population and high-risk subgroups. The test characteristics of multiple two-item combinations of questions assessing food insecurity had adequate sensitivity (>97 %) and specificity (>70 %) for widespread adoption as clinical screening measures. We recommend two specific items for clinical screening programmes based on their widespread current use and high sensitivity for detecting food insecurity. These items query how often the household 'worried whether food would run out before we got money to buy more' and how often 'the food that we bought just didn't last and we didn't have money to get more'. The recommended items have sensitivity across high-risk population subgroups of ≥97 % and a specificity of ≥74 % for food insecurity.
Crain, Ellen F; Walter, Michelle; O'Connor, George T; Mitchell, Herman; Gruchalla, Rebecca S; Kattan, Meyer; Malindzak, George S; Enright, Paul; Evans, Richard; Morgan, Wayne; Stout, James W
2002-01-01
Most published environmental remediation interventions have been directed at single allergens and have employed demanding strategies; few have been performed in the homes of inner-city children disproportionately burdened by asthma. Our objective was a) to describe the allergen sensitivities, environmental tobacco smoke (ETS) exposure, and home environmental characteristics of a national sample of inner-city children with moderate to severe asthma and b) to develop and implement a multifaceted, home-based comprehensive intervention to reduce home allergens and ETS, tailored to the specific sensitization and exposure profiles of those children. Allergen skin testing and a home evaluation were performed to determine the presence of ETS and factors known to be associated with increased indoor allergen levels. Based on published remediation techniques, a home environmental intervention, organized into modules, each addressing one of five specific allergen groups or ETS, was designed. Of 994 allergic children from seven U.S. urban communities, 937 successfully completed baseline interviews and home allergen surveys and were enrolled. More than 50% of children had positive skin tests to three or more allergen groups. Cockroaches were reported in 58% of homes, wall-to-wall carpeting in the child's bedroom in 55%, a smoker in 48%, mice or rats in 40%, and furry pets in 28%. More than 60% of enrolled families received four or more modules, and between 94% and 98% of all modules were completed. We conclude that most inner-city children with moderate to severe asthma are sensitized to multiple indoor allergens and that environmental factors known to be associated with asthma severity are commonly present in their homes. The intervention developed for the Inner-City Asthma Study employs accepted methods to address an array of allergens and ETS exposure while ensuring that the intervention is tailored to the specific sensitization profiles and home characteristics of these children. PMID:12204830
NASA Astrophysics Data System (ADS)
Furlong, Cosme; Yokum, Jeffrey S.; Pryputniewicz, Ryszard J.
2002-06-01
Sensitivity, accuracy, and precision characteristics in quantitative optical metrology techniques, and specifically in optoelectronic holography based on fiber optics and high-spatial and high-digital resolution cameras, are discussed in this paper. It is shown that sensitivity, accuracy, and precision dependent on both, the effective determination of optical phase and the effective characterization of the illumination-observation conditions. Sensitivity, accuracy, and precision are investigated with the aid of National Institute of Standards and Technology (NIST) traceable gages, demonstrating the applicability of quantitative optical metrology techniques to satisfy constantly increasing needs for the study and development of emerging technologies.
Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio
2009-04-01
A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.
Strappini, Francesca; Gilboa, Elad; Pitzalis, Sabrina; Kay, Kendrick; McAvoy, Mark; Nehorai, Arye; Snyder, Abraham Z
2017-03-01
Temporal and spatial filtering of fMRI data is often used to improve statistical power. However, conventional methods, such as smoothing with fixed-width Gaussian filters, remove fine-scale structure in the data, necessitating a tradeoff between sensitivity and specificity. Specifically, smoothing may increase sensitivity (reduce noise and increase statistical power) but at the cost loss of specificity in that fine-scale structure in neural activity patterns is lost. Here, we propose an alternative smoothing method based on Gaussian processes (GP) regression for single subjects fMRI experiments. This method adapts the level of smoothing on a voxel by voxel basis according to the characteristics of the local neural activity patterns. GP-based fMRI analysis has been heretofore impractical owing to computational demands. Here, we demonstrate a new implementation of GP that makes it possible to handle the massive data dimensionality of the typical fMRI experiment. We demonstrate how GP can be used as a drop-in replacement to conventional preprocessing steps for temporal and spatial smoothing in a standard fMRI pipeline. We present simulated and experimental results that show the increased sensitivity and specificity compared to conventional smoothing strategies. Hum Brain Mapp 38:1438-1459, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Performance characteristics of digital vs film screen mammography in community practice.
Dabbous, Firas; Dolecek, Therese A; Friedewald, Sarah M; Tossas-Milligan, Katherine Y; Macarol, Tere; Summerfelt, Wm Thomas; Rauscher, Garth H
2018-05-01
We compared the performance characteristics of 297 629 full field digital (FFDM) and 416 791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1%-2% points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs SFM in our study may partially explain performance differences by modality. In this large health care organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM. © 2017 Wiley Periodicals, Inc.
Basova, N E; Kormilitsyn, B N; Perchenok, A Yu; Rozengart, E V; Saakov, V S; Suvorov, A A
2015-01-01
The review presents data on comparative reactivity of 68 cholinesterase preparation from various organs and tissues in a number of vertebrates and invertebrates based on sensitivity to two highly specific and most studied organophosphorus inhibitors--diisopropyl fluorophosphates (DFP) and (2-ethoxymethyl phosphoryl thioethyl) ethyl (methyl) sulphonium sulphomethylat (GD-42). Analysis of these data suggests a great diversity in enzymologic characteristics of cholinesterase preparation in representatives of vertebrates and invertebrates, this variety observed even for closely related enzymes in animals of almost the same level of development.
Disgust sensitivity is primarily associated with purity-based moral judgments.
Wagemans, Fieke M A; Brandt, Mark J; Zeelenberg, Marcel
2018-03-01
Individual differences in disgust sensitivity are associated with a range of judgments and attitudes related to the moral domain. Some perspectives suggest that the association between disgust sensitivity and moral judgments will be equally strong across all moral domains (i.e., purity, authority, loyalty, care, fairness, and liberty). Other perspectives predict that disgust sensitivity is primarily associated with judgments of specific moral domains (e.g., primarily purity). However, no study has systematically tested if disgust sensitivity is associated with moral judgments of the purity domain specifically, more generally to moral judgments of the binding moral domains, or to moral judgments of all of the moral domains equally. Across 5 studies (total N = 1,104), we find consistent evidence for the notion that disgust sensitivity relates more strongly to moral condemnation of purity-based transgressions (meta-analytic r = .40) than to moral condemnation of transgressions of any of the other domains (range meta-analytic rs: .07-.27). Our findings are in line with predictions from Moral Foundations Theory, which predicts that personality characteristics like disgust sensitivity make people more sensitive to a certain set of moral issues. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.
Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu
2017-09-01
The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Harper, Lorie M; Gray, Diana; Dicke, Jeffrey; Stamilio, David M; Macones, George A; Odibo, Anthony O
2010-02-01
The purpose of this study was to determine whether the use of race-specific definitions of short femur and humerus lengths improves Down syndrome detection. This was a retrospective cohort study over 16 years. For each self-reported maternal race (white, African American, Hispanic, and Asian), we evaluated the efficiency of Down syndrome detection using published race-specific formulas compared with a standard formula for short femur and humerus lengths (observed versus expected lengths < or =0.91 and < or =0.89, respectively). The sensitivity, specificity, and 95% confidence intervals for each parameter were compared. Screening performance was compared by areas under the receiver operating characteristic curves. Of 58,710 women, 209 (0.3%) had a diagnosis of a fetus with Down syndrome. Although the race-based formula increased sensitivity in each population, the increase was statistically significant only in the white population, whereas a decrease in specificity was statistically significant in all 4 populations, as denoted by nonoverlapping confidence intervals. The area under the receiver operating characteristic curve for the model using the race-specific definition of short femur length was 0.67 versus 0.65 compared with the standard definition, and for humerus length it was 0.70 versus 0.71. The use of race-based formulas for the determination of short femur and humerus lengths did not significantly improve the detection rates for Down syndrome.
Song, Mi-Kyung; Ryu, Jae-Chun
2015-10-01
To date, there is still shortage of highly sensitive and specific minimally invasive biomarkers for assessment of environmental toxicants exposure. Because of the significance of microRNA (miRNA) in various diseases, circulating miRNAs in blood may be unique biomarkers for minimally invasive prediction of toxicants exposure. We identified and validated characteristic miRNA expression profiles of human whole blood in workers exposed to volatile organic compounds (VOCs) and compared the usefulness of miRNA indicator of VOCs with the effectiveness of the already used urinary biomarkers of occupational exposure. Using a microarray based approach we screened and detected deregulated miRNAs in their expression in workers exposed to VOCs (toluene [TOL], xylene [XYL] and ethylbenzene [EBZ]). Total 169 workers from four dockyards were enrolled in current study, and 50 subjects of them were used for miRNA microarray analysis. We identified 467 miRNAs for TOL, 211 miRNAs for XYL, and 695 miRNAs for XYL as characteristic discernible exposure indicator, which could discerned each VOC from the control group with higher accuracy, sensitivity, and specificity than urinary biomarkers. Current observations from this study point out that the altered levels of circulating miRNAs can be a reliable novel, minimally invasive biological indicator of occupational exposure to VOCs. Copyright © 2015 Elsevier GmbH. All rights reserved.
Diagnosis of Tempromandibular Disorders Using Local Binary Patterns.
Haghnegahdar, A A; Kolahi, S; Khojastepour, L; Tajeripour, F
2018-03-01
Temporomandibular joint disorder (TMD) might be manifested as structural changes in bone through modification, adaptation or direct destruction. We propose to use Local Binary Pattern (LBP) characteristics and histogram-oriented gradients on the recorded images as a diagnostic tool in TMD assessment. CBCT images of 66 patients (132 joints) with TMD and 66 normal cases (132 joints) were collected and 2 coronal cut prepared from each condyle, although images were limited to head of mandibular condyle. In order to extract features of images, first we use LBP and then histogram of oriented gradients. To reduce dimensionality, the linear algebra Singular Value Decomposition (SVD) is applied to the feature vectors matrix of all images. For evaluation, we used K nearest neighbor (K-NN), Support Vector Machine, Naïve Bayesian and Random Forest classifiers. We used Receiver Operating Characteristic (ROC) to evaluate the hypothesis. K nearest neighbor classifier achieves a very good accuracy (0.9242), moreover, it has desirable sensitivity (0.9470) and specificity (0.9015) results, when other classifiers have lower accuracy, sensitivity and specificity. We proposed a fully automatic approach to detect TMD using image processing techniques based on local binary patterns and feature extraction. K-NN has been the best classifier for our experiments in detecting patients from healthy individuals, by 92.42% accuracy, 94.70% sensitivity and 90.15% specificity. The proposed method can help automatically diagnose TMD at its initial stages.
The role of disgust in patients with hypochondriasis.
Weck, Florian; Esch, Sebastian; Rohrmann, Sonja
2014-01-01
Theoretically, disgust sensitivity and disgust proneness could play an important role in hypochondriasis, since disgust is a defensive emotion widely believed to protect the organism from illness. However, empirical evidence to support this hypothesis has so far been based only on nonclinical samples, so that the importance and specificity of disgust for hypochondriasis remains unclear. In the current study, 36 patients with hypochondriasis, 27 with an anxiety disorder, and 29 healthy controls completed several measures which included the assessment of disgust sensitivity (Scale for the Assessment of Disgust Sensitivity) and disgust proneness (Questionnaire for the Assessment of Disgust Proneness). We found that patients with hypochondriasis and those with an anxiety disorder had higher scores than those of the healthy controls for several measures of disgust proneness. Moreover, measures of hypochondriacal characteristics were associated with those of disgust proneness and disgust sensitivity. However, no differences were found between patients with hypochondriasis and those with anxiety disorders, with respect to disgust proneness and disgust sensitivity. Therefore, it can be assumed that disgust proneness and disgust sensitivity seem to be less specific than previously suggested for the development and maintenance of hypochondriasis.
Pilot study analyzing automated ECG screening of hypertrophic cardiomyopathy.
Campbell, Matthew J; Zhou, Xuefu; Han, Chia; Abrishami, Hedayat; Webster, Gregory; Miyake, Christina Y; Sower, Christopher T; Anderson, Jeffrey B; Knilans, Timothy K; Czosek, Richard J
2017-06-01
Hypertrophic cardiomyopathy (HCM) is one of the leading causes of sudden cardiac death in athletes. However, preparticipation ECG screening has often been criticized for failing to meet cost-effectiveness thresholds, in part because of high false-positive rates and the cost of ECG screening itself. The purpose of this study was to assess the testing characteristics of an automated ECG algorithm designed to screen for HCM in a multi-institutional pediatric cohort. ECGs from patients with HCM aged 12 to 20 years from 3 pediatric institutions were screened for ECG criteria for HCM using a previously described automated computer algorithm developed specifically for HCM ECG screening. The results were compared to a known healthy pediatric cohort. The studies then were read by trained electrophysiologists using standard ECG criteria and compared to the results of automated screening. One hundred twenty-eight ECGs from unique patients with phenotypic HCM were obtained and compared with 256 studies from healthy control patients matched in 2:1 fashion. When presented with the ECGs, the non-voltage-based algorithm resulted in 81.2% sensitivity and 90.7% specificity. A trained electrophysiologist read the same data according to the Seattle Criteria, with 71% sensitivity with 95.7% specificity. The sensitivity of screening as well as the components of the ECG screening itself varied by institution. This pilot study demonstrates a potential for automated ECG screening algorithms to detect HCM with testing characteristics similar to that of a trained electrophysiologist. In addition, there appear to be differences in ECG characteristics between patient populations, which may account for the difficulties in universal screening. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach
Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette
2011-01-01
Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745
Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department
Balamuth, Fran; Alpern, Elizabeth R.; Grundmeier, Robert W.; Chilutti, Marianne; Weiss, Scott L.; Fitzgerald, Julie C.; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing
2015-01-01
Objectives To compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). Methods This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Results Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159, and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% CI = 72.1% to 73.4%) and specificity 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity 92.1% (95% CI = 91.7% to 92.4%), and specificity 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment vs. algorithmic alert were 40.3% vs. 2.5% and 99.88 % vs. 99.96%, respectively. Conclusions The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. PMID:26474032
Comparison of Two Sepsis Recognition Methods in a Pediatric Emergency Department.
Balamuth, Fran; Alpern, Elizabeth R; Grundmeier, Robert W; Chilutti, Marianne; Weiss, Scott L; Fitzgerald, Julie C; Hayes, Katie; Bilker, Warren; Lautenbach, Ebbing
2015-11-01
The objective was to compare the effectiveness of physician judgment and an electronic algorithmic alert to identify pediatric patients with severe sepsis/septic shock in a pediatric emergency department (ED). This was an observational cohort study of patients older than 56 days with fever or hypothermia. All patients were evaluated for potential sepsis in real time by the ED clinical team. An electronic algorithmic alert was retrospectively applied to identify patients with potential sepsis independent of physician judgment. The primary outcome was the proportion of patients correctly identified with severe sepsis/septic shock defined by consensus criteria. Test characteristics were determined and receiver operating characteristic (ROC) curves were compared. Of 19,524 eligible patient visits, 88 patients developed consensus-confirmed severe sepsis or septic shock. Physician judgment identified 159 and the algorithmic alert identified 3,301 patients with potential sepsis. Physician judgment had sensitivity of 72.7% (95% confidence interval [CI] = 72.1% to 73.4%) and specificity of 99.5% (95% CI = 99.4% to 99.6%); the algorithmic alert had sensitivity of 92.1% (95% CI = 91.7% to 92.4%) and specificity of 83.4% (95% CI = 82.9% to 83.9%) for severe sepsis/septic shock. There was no significant difference in the area under the ROC curve for physician judgment (0.86, 95% CI = 0.81 to 0.91) or the algorithm (0.88, 95% CI = 0.85 to 0.91; p = 0.54). A combination method using either positive physician judgment or an algorithmic alert improved sensitivity to 96.6% and specificity to 83.3%. A sequential approach, in which positive identification by the algorithmic alert was then confirmed by physician judgment, achieved 68.2% sensitivity and 99.6% specificity. Positive and negative predictive values for physician judgment versus algorithmic alert were 40.3% versus 2.5% and 99.88% versus 99.96%, respectively. The electronic algorithmic alert was more sensitive but less specific than physician judgment for recognition of pediatric severe sepsis and septic shock. These findings can help to guide institutions in selecting pediatric sepsis recognition methods based on institutional needs and priorities. © 2015 by the Society for Academic Emergency Medicine.
Tully, Phillip J; Wardenaar, Klaas J; Penninx, Brenda W J H
2015-03-15
The receiver operating characteristics (ROC) of anhedonic depression and anxious arousal to detect the distress- (major depression, dysthymia, generalized anxiety disorder) and fear-disorder clusters (i.e. panic disorder, agoraphobia, social phobia) have not been reported in a large sample. A sample of 2981 persons underwent structured psychiatric interview; n=652 were without lifetime depression and anxiety disorder history. Participants also completed a neuroticism scale (Revised NEO Five Factor Inventory [NEO-FFI]), and the 30-item short adaptation of the Mood and Anxiety Symptoms Questionnaire (MASQ-D30) measuring anhedonic depression, anxious arousal and general distress. Maximal sensitivity and specificity was determined by the Youden Index and the area-under-the-curve (AUC) in ROC analysis. A total of 2624 completed all measures (age M=42.4 years±13.1, 1760 females [67.1%]), including 1060 (40.4%) persons who met criteria for a distress-disorder, and 973 (37.1%) who met criteria for a fear-disorder. The general distress dimension provided the highest ROC values in the detection of the distress-disorders (AUC=.814, sensitivity=71.95%, specificity=76.34%, positive predictive value=67.33, negative predictive value=80.07). None of the measures provided suitable operating characteristics in the detection of the fear-disorders with specificity values <75%. Over sampling of depression and anxiety disorders may lead to inflated positive- and negative predictive values. The MASQ-D30 general distress dimension showed clinically suitable operating characteristics in the detection of distress-disorders. Neither neuroticism nor the MASQ-D30 dimensions provided suitable operating characteristics in the detection of the fear-disorders. Copyright © 2014 Elsevier B.V. All rights reserved.
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.
2014-01-01
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157
Giachetti, C.; Linnen, J. M.; Kolk, D. P.; Dockter, J.; Gillotte-Taylor, K.; Park, M.; Ho-Sing-Loy, M.; McCormick, M. K.; Mimms, L. T.; McDonough, S. H.
2002-01-01
Various nucleic acid assays have been developed and implemented for diagnostics and therapeutic monitoring of human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) infections. The high-throughput, semiautomated assays described here were developed to provide a method suitable for screening plasma specimens for the presence of HIV-1 and HCV RNAs. Three assays were developed: a multiplex HIV-1/HCV assay for simultaneous detection of HIV-1 and HCV, and discriminatory assays for specific detection of HIV-1 and HCV. The assay systems utilize three proprietary technologies: (i) target capture-based sample preparation, (ii) transcription-mediated amplification (TMA), and (iii) hybridization protection assay (HPA). An internal control is incorporated into each reaction to control for every step of the assay and identify random false-negative reactions. The assays demonstrated a sensitivity of at least 100 copies/ml for each target, and they detected with similar sensitivity all major variants of HCV and HIV-1, including HIV-1 group O strains. Assay sensitivity for one virus was not affected by the presence of the other. The specificity of these TMA-driven assays was ≥99.5% in both normal donor specimens and plasma containing potentially interfering substances or other blood-borne pathogens. Statistical receiver operating characteristic plots of 1 − specificity versus sensitivity data determined very wide analyte cutoff values for each assay at the point at which the assay specificity and sensitivity were both ≥99.5%. The sensitivity, specificity, and throughput capability predict that these assays will be valuable for large-volume plasma screening, either in a blood bank setting or in other diagnostic applications. PMID:12089255
Balhara, Yatan Pal Singh; Jain, Raka
2013-01-01
Tobacco use has been associated with various carcinomas including lung, esophagus, larynx, mouth, throat, kidney, bladder, pancreas, stomach, and cervix. Biomarkers such as concentration of cotinine in the blood, urine, or saliva have been used as objective measures to distinguish nonusers and users of tobacco products. A change in the cut-off value of urinary cotinine to detect active tobacco use is associated with a change in sensitivity and sensitivity of detection. The current study aimed at assessing the impact of using different cut-off thresholds of urinary cotinine on sensitivity and specificity of detection of smoking and smokeless tobacco product use among psychiatric patients. All the male subjects attending the psychiatry out-patient department of the tertiary care multispecialty teaching hospital constituted the sample frame for the current study in a cross-sectionally. Quantitative urinary cotinine assay was done by using ELISA kits of Calbiotech. Inc., USA. We used the receiver operating characteristic (ROC) curve to assess the sensitivity and specificity of various cut-off values of urinary cotinine to identify active smokers and users of smokeless tobacco products. ROC analysis of urinary cotinine levels in detection of self-reported smoking provided the area under curve (AUC) of 0.434. Similarly, the ROC analysis of urinary cotinine levels in detection of self-reported smoking revealed AUC of 0.44. The highest sensitivity and specificity of 100% for smoking were detected at the urinary cut-off value greater than or equal to 2.47 ng/ml. The choice of cut-off value of urinary cotinine used to distinguish nonusers form active users of tobacco products impacts the sensitivity as well as specificity of detection.
Coburger, Jan; Scheuerle, Angelika; Kapapa, Thomas; Engelke, Jens; Thal, Dietmar Rudolf; Wirtz, Christian R; König, Ralph
2015-07-01
Linear array intraoperative ultrasound (lioUS) is an emerging technology for intracranial use. We evaluated sensitivity and specificity of lioUS to detect residual tumor in patients harboring a glioblastoma. After near total resection in 20 patients, residual tumor detection using lioUS, conventional intraoperative ultrasound (cioUS), and gadopentetic-diethylenetriamine penta-acetic acid (Gd-DTPA)-enhanced intraoperative MRI (iMRI) were compared. Sensitivity and specificity were calculated based on 68 navigated biopsies. Receiver operator characteristic (ROC) curves and correlation with histopathological findings of each imaging modality were calculated. Additionally, results were evaluated in the subgroup of recurrent disease (23 biopsies in 8 patients). Sensitivity of lioUS (76 %) was significantly higher compared with iMRI (55 %) and cioUS (24 %). Specificity of lioUS (58 %) was significantly lower than in cioUS (96 %), while there was no significant difference to iMRI (74 %). All imaging modalities correlated significantly with histopathological findings. In the subgroup of recurrent disease, sensitivity and specificity decreased in all modalities. However, cioUS showed significant lower values than iMRI and lioUS. In ROC curves, lioUS showed a higher area und the curve (AUC) in comparison with iMRI and cioUS. We found similar results in the subgroup of recurrent disease. Tumor detection using a lioUS is significantly superior to cioUS. Overall test performance in lioUS is comparable with results of iMRI. While, the latter has a higher specificity and a significantly lower sensitivity in comparison with lioUS.
Pinchi, Vilma; Pradella, Francesco; Vitale, Giulia; Rugo, Dario; Nieri, Michele; Norelli, Gian-Aristide
2016-01-01
The age threshold of 14 years is relevant in Italy as the minimum age for criminal responsibility. It is of utmost importance to evaluate the diagnostic accuracy of every odontological method for age evaluation considering the sensitivity, or the ability to estimate the true positive cases, and the specificity, or the ability to estimate the true negative cases. The research aims to compare the specificity and sensitivity of four commonly adopted methods of dental age estimation - Demirjian, Haavikko, Willems and Cameriere - in a sample of Italian children aged between 11 and 16 years, with an age threshold of 14 years, using receiver operating characteristic curves and the area under the curve (AUC). In addition, new decision criteria are developed to increase the accuracy of the methods. Among the four odontological methods for age estimation adopted in the research, the Cameriere method showed the highest AUC in both female and male cohorts. The Cameriere method shows a high degree of accuracy at the age threshold of 14 years. To adopt the Cameriere method to estimate the 14-year age threshold more accurately, however, it is suggested - according to the Youden index - that the decision criterion be set at the lower value of 12.928 for females and 13.258 years for males, obtaining a sensitivity of 85% and specificity of 88% in females, and a sensitivity of 77% and specificity of 92% in males. If a specificity level >90% is needed, the cut-off point should be set at 12.959 years (82% sensitivity) for females. © The Author(s) 2015.
Optimal CINAHL search strategies for identifying therapy studies and review articles.
Wong, Sharon S L; Wilczynski, Nancy L; Haynes, R Brian
2006-01-01
To design optimal search strategies for locating sound therapy studies and review articles in CiNAHL in the year 2000. An analytic survey was conducted, comparing hand searches of 75 journals with retrievals from CINAHL for 5,020 candidate search terms and 17,900 combinations for therapy and 5,977 combinations for review articles. All articles were rated with purpose and quality indicators. Candidate search strategies were used in CINAHL, and the retrievals were compared with results of the hand searches. The proposed search strategies were treated as "diagnostic tests" for sound studies and the manual review of the literature was treated as the "gold standard." Operating characteristics of the search strategies were calculated. Of the 1,383 articles about treatment, 506 (36.6%) met basic criteria for scientific merit and 127 (17.9%) of the 711 articles classified as a review met the criteria for systematic reviews. For locating sound treatment studies, a three-term strategy maximized sensitivity at 99.4% but with compromised specificity at 58.3%, and a two-term strategy maximized specificity at 98.5% but with compromised sensitivity at 52.0%. For detecting systematic reviews, a three-term strategy maximized sensitivity at 91.3% while keeping specificity high at 95.4%, and a single-term strategy maximized specificity at 99.6% but with compromised sensitivity at 42.5%. Three-term search strategies optimizing sensitivity and specificity achieved these values over 91% for detecting sound treatment studies and over 76% for detecting systematic reviews. Search strategies combining indexing terms and text words can achieve high sensitivity and specificity for retrieving sound treatment studies and review articles in CINAHL.
ECG Criteria to Differentiate Between Takotsubo (Stress) Cardiomyopathy and Myocardial Infarction.
Frangieh, Antonio H; Obeid, Slayman; Ghadri, Jelena-Rima; Imori, Yoichi; D'Ascenzo, Fabrizio; Kovac, Marc; Ruschitzka, Frank; Lüscher, Thomas F; Duru, Firat; Templin, Christian
2016-06-13
ECG criteria differentiating Takotsubo cardiomyopathy (TTC) from mainly anterior myocardial infarction (MI) have been suggested; however, this was in small patient populations. Twelve-lead admission ECGs of consecutive 200 TTC and 200 MI patients were compared in dichotomized groups based on the presence or absence of ST-elevation MI (STEMI versus STE-TTC and non-ST elevation MI versus non ST-elevation-TTC). When comparing STEMI and STE-TTC, ST-elevation in -aVR was characteristic of STE-TTC with a sensitivity/specificity of 43% and 95%, positive predictive value (PPV) 91%, and a negative predictive value (NPV) 62% (P<0.001); when ST-elevation in -aVR is accompanied by ST-elevation in inferior leads, sensitivity/specificity were 14% and 98% (PPV was 89% and NPV 52%) (P=0.001), and 12% and 100% when associated with ST-elevation in anteroseptal leads (PPV 100%, NPV 52%) (P<0.001). On the other hand, STEMI was characterized by ST-elevation in aVR (sensitivity/specificity of 31% and 95% P<0.001, PPV 85% and NPV 59%) and ST-depression in V2-V3-V4 (sensitivity/specificity of 24% and 100% P<0.001, PPV 100% and NPV 76%). When comparing non-ST elevation MI and non ST-elevation-TTC, T-inversion in leads I-aVL-V5-V6 had a sensitivity/specificity of 17% and 97% for non ST-elevation-TTC (PPV 83% and NPV 55%) (P<0.001), and ST-elevation in -aVR with T-inversion in any lead was also specific for non ST-elevation-TTC (sensitivity/specificity of 8% and 100%, PPV 100% and NPV 53%) (P=0.006). In non-ST elevation MI patients, the presence of ST-depression in V2-V3 was specific (sensitivity/specificity of 11% and 99%, PPV 91% and NPV 51%) (P=0.01). ECG on admission can differentiate between TTC and acute MI, with high specificity and positive predictive value. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01947621. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Il faut bien faire avec des bribes, hein! (You Have to Make Do with Scraps, Huh?)
ERIC Educational Resources Information Center
Malandain, Jean-Louis
1983-01-01
Suggestions are made for structuring taped listening exercises to promote careful attention to various elements of spontaneous speech (speaker, speaker characteristics, tone, etc.), and to sensitize students to the usage of "hein" or other specific expressions. (MSE)
Warkentin, Theodore E; Sheppard, Jo-Ann I; Linkins, Lori-Ann; Arnold, Donald M; Nazy, Ishac
2017-05-01
Heparin-induced thrombocytopenia (HIT) is a prothrombotic drug reaction caused by platelet-activating anti-PF4/heparin antibodies. Given time-sensitive treatment considerations, a rapid and accurate laboratory test for HIT antibodies is needed. To determine operating characteristics for the HemosIL ® HIT-Ab (PF4/H) , a rapid, on-demand, fully-automated, latex immunoturbidimetric assay (LIA), for diagnosis of HIT. We evaluated LIA sensitivity, specificity, negative (NPV) and positive predictive value (PPV), negative (LR-) and positive likelihood ratio (LR+), using citrated-plasma from 429 patients (prospective cohort study of 4Ts scoring; HIT, n=31), and from consecutive HIT patients (n=125), using reference standard serotonin-release assay (SRA). Comparators included two PF4-dependent enzyme-immunoassays (EIAs). We used stratum-specific likelihood ratios (SSLRs) to determine how differing magnitudes of LIA-positivity influenced post-test probability of HIT. LIA operating characteristics were: sensitivity=97.4% (152/156); specificity=94.0% (374/398); PPV=55.6% (30/54); and NPV=99.7% (374/375). At manufacturers' cutoffs, LIA specificity and PPV were superior to the EIAs. Although a negative LIA pointed strongly against HIT (LR-, 0.034), the post-test probability was ~2% with high 4Ts score. The LIA's LR+ was high (16.0), with SSLRs rising substantially with greater LIA-positivity: 5.7 (1.0-4.9U/mL), 31 (5.0-15.9U/mL), and 128 (≥16U/mL). A LIA-positive result (at 1.0 cutoff) indicated at least 24% HIT probability (low 4Ts score), rising to 90% with high 4Ts score. Although approximately 1 in 40 SRA-positive patients tested LIA-negative, the LIA's high NPV and PPV indicate that this rapid assay is useful for the diagnostic evaluation of HIT, including in low pre-test situations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Horiuchi, Toshikatsu; Ogata, Sho; Tominaga, Susumu; Hiroi, Sadayuki; Kawahara, Kunimitsu; Hebisawa, Akira; Irei, Isao; Ito, Ichiro; Kameya, Toru; Tsujimura, Tohru; Nakano, Takashi; Nakanishi, Kuniaki; Kawai, Toshiaki
2013-05-01
It is difficult to distinguish desmoplastic malignant mesothelioma (DMM) from fibrous pleuritis (FP). We investigated the utility of immunohistochemistry as a way of differentiating between DMM and FP. We examined 11 DMMs and 46 FPs with the aid of antibodies against 18 cytokeratin (CK) subtypes, calponin, caldesmon, desmin, and GLUT-1. The best sensitivity and specificity cut-off values in the receiver operating characteristic curves (ROC) for CKs 7, 8, 17, 18, and 19, and GLUT-1 were each above 60%. When cases with either DMM or FP were partitioned by the staining score associated with the best sensitivity and specificity cut-off values in ROC, the incidence of a positive expression for CKs 7, 8, 17, 18, and 19, and GLUT-1 was significantly higher in DMM than in FP. In conclusion, immunohistochemistry for CKs 7, 8, 17, 18, and 19, and GLUT-1 may be useful, alongside histological characteristics, for separating DMM from FP.
Banks, Emily; Reeves, Gillian; Beral, Valerie; Bull, Diana; Crossley, Barbara; Simmonds, Moya; Hilton, Elizabeth; Bailey, Stephen; Barrett, Nigel; Briers, Peter; English, Ruth; Jackson, Alan; Kutt, Elizabeth; Lavelle, Janet; Rockall, Linda; Wallis, Matthew G; Wilson, Mary; Patnick, Julietta
2004-01-01
Objectives To examine how lifestyle, hormonal, and other factors influence the sensitivity and specificity of mammography. Methods Women recruited into the Million Women Study completed a questionnaire about various personal factors before routine mammographic screening. A sample of 122 355 women aged 50-64 years were followed for outcome of screening and incident breast cancer in the next 12 months. Sensitivity and specificity were calculated by using standard definitions, with adjustment for potential confounding factors. Results Breast cancer was diagnosed in 726 (0.6%) women, 629 in screen positive and 97 in screen negative women; 3885 (3.2%) were screen positive but had no subsequent diagnosis of breast cancer. Overall sensitivity was 86.6% and specificity was 96.8%. Three factors had an adverse effect on both measures: use of hormone replacement therapy (sensitivity: 83.0% (95% confidence interval 77.4% to 87.6%), 84.7% (73.9% to 91.6%), and 92.1% (87.6% to 95.0%); specificity: 96.8% (96.6% to 97.0%), 97.8% (97.5% to 98.0%), and 98.1% (98.0% to 98.2%), respectively, for current, past, and never use); previous breast surgery v no previous breast surgery (sensitivity: 83.5% (75.7% to 89.1%) v 89.4% (86.5% to 91.8%); specificity: 96.2% (95.8% to 96.5%) v 97.4% (97.3% to 97.5%), respectively); and body mass index < 25 v ≥ 25 (sensitivity: 85.7% (81.2% to 89.3%) v 91.0% (87.5% to 93.6%); specificity: 97.2% (97.0% to 97.3%) v 97.4% (97.3% to 97.6%), respectively). Neither sensitivity nor specificity varied significantly according to age, family history of breast cancer, parity, past oral contraceptive use, tubal ligation, physical activity, smoking, or alcohol consumption. Conclusions The efficiency, and possibly the effectiveness, of mammographic screening is lower in users of hormone replacement therapy, in women with previous breast surgery, and in thin women compared with other women. PMID:15331472
Blackmore, C Craig; Terasawa, Teruhiko
2006-02-01
Error in radiology can be reduced by standardizing the interpretation of imaging studies to the optimum sensitivity and specificity. In this report, the authors demonstrate how the optimal interpretation of appendiceal computed tomography (CT) can be determined and how it varies in different clinical scenarios. Utility analysis and receiver operating characteristic (ROC) curve modeling were used to determine the trade-off between false-positive and false-negative test results to determine the optimal operating point on the ROC curve for the interpretation of appendicitis CT. Modeling was based on a previous meta-analysis for the accuracy of CT and on literature estimates of the utilities of various health states. The posttest probability of appendicitis was derived using Bayes's theorem. At a low prevalence of disease (screening), appendicitis CT should be interpreted at high specificity (97.7%), even at the expense of lower sensitivity (75%). Conversely, at a high probability of disease, high sensitivity (97.4%) is preferred (specificity 77.8%). When the clinical diagnosis of appendicitis is equivocal, CT interpretation should emphasize both sensitivity and specificity (sensitivity 92.3%, specificity 91.5%). Radiologists can potentially decrease medical error and improve patient health by varying the interpretation of appendiceal CT on the basis of the clinical probability of appendicitis. This report is an example of how utility analysis can be used to guide radiologists in the interpretation of imaging studies and provide guidance on appropriate targets for the standardization of interpretation.
Meta-analysis of diagnostic accuracy studies in mental health
Takwoingi, Yemisi; Riley, Richard D; Deeks, Jonathan J
2015-01-01
Objectives To explain methods for data synthesis of evidence from diagnostic test accuracy (DTA) studies, and to illustrate different types of analyses that may be performed in a DTA systematic review. Methods We described properties of meta-analytic methods for quantitative synthesis of evidence. We used a DTA review comparing the accuracy of three screening questionnaires for bipolar disorder to illustrate application of the methods for each type of analysis. Results The discriminatory ability of a test is commonly expressed in terms of sensitivity (proportion of those with the condition who test positive) and specificity (proportion of those without the condition who test negative). There is a trade-off between sensitivity and specificity, as an increasing threshold for defining test positivity will decrease sensitivity and increase specificity. Methods recommended for meta-analysis of DTA studies --such as the bivariate or hierarchical summary receiver operating characteristic (HSROC) model --jointly summarise sensitivity and specificity while taking into account this threshold effect, as well as allowing for between study differences in test performance beyond what would be expected by chance. The bivariate model focuses on estimation of a summary sensitivity and specificity at a common threshold while the HSROC model focuses on the estimation of a summary curve from studies that have used different thresholds. Conclusions Meta-analyses of diagnostic accuracy studies can provide answers to important clinical questions. We hope this article will provide clinicians with sufficient understanding of the terminology and methods to aid interpretation of systematic reviews and facilitate better patient care. PMID:26446042
Labanca, Ludimila; Alves, Cláudia Regina Lindgren; Bragança, Lidia Lourenço Cunha; Dorim, Diego Dias Ramos; Alvim, Cristina Gonçalves; Lemos, Stela Maris Aguiar
2015-01-01
To establish cutoff points for the analysis of the Behavior Observation Form (BOF) of children in the ages of 2 to 23 months and evaluate the sensitivity and specificity by age group and domains (Emission, Reception, and Cognitive Aspects of Language). The sample consisted of 752 children who underwent BOF. Each child was classified as having appropriate language development for the age or having possible risk of language impairment. Performance Indicators (PI) were calculated in each domain as well as the overall PI in all domains. The values for sensitivity and specificity were also calculated. The cutoff points for possible risk of language impairment for each domain and each age group were obtained using the receiver operating characteristics curve. The results of the study revealed that one-third of the assessed children have a risk of language impairment in the first two years of life. The analysis of BOF showed high sensitivity (>90%) in all categories and in all age groups; however, the chance of false-positive results was higher than 20% in the majority of aspects evaluated. It was possible to establish the cutoff points for all categories and age groups with good correlation between sensitivity and specificity, except for the age group of 2 to 6 months. This study provides important contributions to the discussion on the evaluation of the language development of children younger than 2 years.
The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.
Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia
2014-11-01
The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.
Castellanos-Ryan, Natalie; O'Leary-Barrett, Maeve; Sully, Laura; Conrod, Patricia
2013-01-01
This study assessed the validity, sensitivity, and specificity of the Substance Use Risk Profile Scale (SURPS), a measure of personality risk factors for substance use and other behavioral problems in adolescence. The concurrent and predictive validity of the SURPS was tested in a sample of 1,162 adolescents (mean age: 13.7 years) using linear and logistic regressions, while its sensitivity and specificity were examined using the receiver operating characteristics curve analyses. Concurrent and predictive validity tests showed that all 4 brief scales-hopelessness (H), anxiety sensitivity (AS), impulsivity (IMP), and sensation seeking (SS)-were related, in theoretically expected ways, to measures of substance use and other behavioral and emotional problems. Results also showed that when using the 4 SURPS subscales to identify adolescents "at risk," one can identify a high number of those who developed problems (high sensitivity scores ranging from 72 to 91%). And, as predicted, because each scale is related to specific substance and mental health problems, good specificity was obtained when using the individual personality subscales (e.g., most adolescents identified at high risk by the IMP scale developed conduct or drug use problems within the next 18 months [a high specificity score of 70 to 80%]). The SURPS is a valuable tool for identifying adolescents at high risk for substance misuse and other emotional and behavioral problems. Implications of findings for the use of this measure in future research and prevention interventions are discussed. Copyright © 2012 by the Research Society on Alcoholism.
Fang, Y G; Chen, N N; Cheng, Y B; Sun, S J; Li, H X; Sun, F; Xiang, Y
2015-12-01
Urinary neutrophil gelatinase-associated lipocalin (uNGAL) is relatively specific in lupus nephritis (LN) patients. However, its diagnostic value has not been evaluated. The aim of this review was to determine the value of uNGAL for diagnosis and estimating activity in LN. A comprehensive search was performed on PubMed, EMBASE, Web of Knowledge, Cochrane electronic databases through December 2014. Meta-analysis of sensitivity and specificity was performed with a random-effects model. Additionally, summary receiver operating characteristic (SROC) curves and area under the curve (AUC) values were calculated. Fourteen studies were selected for this review. With respect to diagnosing LN, the pooled sensitivity and specificity were 73.6% (95% confidence interval (CI), 61.9-83.3) and 78.1% (95% CI, 69.0-85.6), respectively. The SROC-AUC value was 0.8632. Regarding estimating LN activity, the pooled sensitivity and specificity were 66.2% (95% CI, 60.4-71.7) and 62.1% (95% CI, 57.9-66.3), respectively. The SROC-AUC value was 0.7583. In predicting renal flares, the pooled sensitivity and specificity were 77.5% (95% CI, 68.1-85.1) and 65.3% (95% CI, 60.0-70.3), respectively. The SROC-AUC value was 0.7756. In conclusion, this meta-analysis indicates that uNGAL has relatively fair sensitivity and specificity in diagnosing LN, estimating LN activity and predicting renal flares, suggesting that uNGAL is a potential biomarker in diagnosing LN and monitoring LN activity. © The Author(s) 2015.
Bornstein, Marc H.; Putnick, Diane L.; Suwalsky, Joan T. D.; Venuti, Paola; de Falco, Simona; de Galperín, Celia Zingman; Gini, Motti; Tichovolsky, Marianne Heslington
2010-01-01
This study uses country and regional contrasts to examine culture-common and community-specific variation in mother-infant emotional relationships. Altogether, 220 Argentine, Italian, and U.S. American mothers and their daughters and sons, living in rural and metropolitan settings, were observed at home at infant age 5 months. Both variable- and person-centered perspectives of dyadic emotional relationships were analyzed. Supporting the notion that adequate emotional relationships are a critical and culture-common characteristic of human infant development, across all samples most dyads scored in the adaptive range in terms of emotional relationships. Giving evidence of community-specific characteristics, Italian mothers were more sensitive, and Italian infants more responsive, than Argentine and U.S. mothers and infants; in addition, rural mothers were more intrusive than metropolitan mothers, and rural dyads more likely than expected to be classified as mid-range in emotional relationships and less likely to be classified as high in emotional relationships. Adaptive emotional relationships appear to be a culture-common characteristic of mother-infant dyads near the beginning of life, but this relational construct is moderated by community-specific (country and regional) context. PMID:22247569
A method for identifying color vision deficiency malingering.
Pouw, Andrew; Karanjia, Rustum; Sadun, Alfredo
2017-03-01
To propose a new test to identify color vision deficiency malingering. An online survey was distributed to 130 truly color vision deficient participants and 160 participants willing to simulate color vision deficiency. The survey contained three sets of six color-adjusted versions of the standard Ishihara color plates each, as well as one set of six control plates. The plates that best discriminated both participant groups were selected for a "balanced" test emphasizing both sensitivity and specificity. A "specific" test that prioritized high specificity was also created by selecting from these plates. Statistical measures of the test (sensitivity, specificity, and Youden index) were assessed at each possible cut-off threshold, and a receiver operating characteristic (ROC) function with its area under the curve (AUC) charted. The redshift plate set was identified as having the highest difference of means between groups (-58%, CI: -64 to -52%), as well as the widest gap between group modes. Statistical measures of the "balanced" test show an optimal cut-off of at least two incorrectly identified plates to suggest malingering (Youden index: 0.773, sensitivity: 83.3%, specificity: 94.0%, AUC of ROC 0.918). The "specific" test was able to identify color vision deficiency simulators with a specificity of 100% when using a cut-off of at least two incorrectly identified plates (Youden index 0.599, sensitivity 59.9%, specificity 100%, AUC of ROC 0.881). Our proposed test for identifying color vision deficiency malingering demonstrates a high degree of reliability with AUCs of 0.918 and 0.881 for the "balanced" and "specific" tests, respectively. A cut-off threshold of at least two missed plates on the "specific" test was able to identify color vision deficiency simulators with 100% specificity.
Allanson, E R; Pattinson, R C; Nathan, E A; Dickinson, J E
2018-05-01
To investigate the utility of umbilical artery (UA) lactate measurements in a South African hospital for assessing intrapartum care and predicting neonatal outcomes. From 3 March-12 November 2014, we conducted a prospective cohort study of UA lactate levels at Kalafong Hospital, Pretoria, South Africa. Following birth, a UA blood sample (<0.5uL) was taken from a double-clamped segment of cord and the lactate measured. Maternal and neonatal characteristics and outcomes were recorded. During the study, there were 4668 deliveries; including 1091 emergency cesarean and 154 instrumental deliveries. A lactate was recorded for 946 deliveries (20.3%). 190 babies required neonatal resuscitation, with an optimal cutoff for lactate of 5.45 mmol/L (sensitivity 68%, specificity 72%). 124 babies required nursery admission with the optimal cutoff for lactate 4.95 mmol/L (sensitivity 61%, specificity 59%). 55 babies had an Apgar score <7 at 5 min and the optimal lactate for this outcome was 5.65 mmol/L (sensitivity 64%, specificity of 69%). Umbilical lactate can be used in a middle-low resource setting as a measurement of intrapartum hypoxia, with reasonable sensitivity and specificity for the prediction of, or need for, resuscitation, admission to the nursery, and low Apgar scores.
Characteristics of stuttering-like disfluencies in Dutch-speaking children.
Boey, Ronny A; Wuyts, Floris L; Van de Heyning, Paul H; De Bodt, Marc S; Heylen, Louis
2007-01-01
The purpose of this study was to compare the characteristics of stuttering-like disfluencies in a group of native Dutch-speaking children who stutter (n=693), with a group of normally fluent children (n=79). Methods involved the observation of stuttering-like disfluencies in participants' conversational speech samples (total 77,200 words), particularly the frequency, duration and physical tension of instances of stuttering. Findings indicate that stuttering-like disfluencies exhibited by children who stutter are significantly more frequent, longer in duration and involve more physical tension when compared to those of normally fluent children. Furthermore, applying a criterion of 3% stuttering-like disfluencies to distinguish stuttering from normally fluent children resulted in a high degree of sensitivity (0.9452) and specificity (0.9747). Results were taken to suggest that characteristics of stuttering-like disfluencies of Dutch-speaking children are similar to those of English-speaking children and that talker group membership criteria for childhood stuttering can reasonably be extrapolated from the Dutch to the English language and vice versa. The reader will be able to: (1) describe characteristics of stuttering-like disfluencies, (2) define properties such as frequency, duration and physical tension for stuttering children and normally fluent children, and (3) make use of data on sensitivity and specificity of the criterion of 3% stuttering-like disfluencies to distinguish stuttering and normally fluent children.
Pearson, Matthew R; Bravo, Adrian J; Kirouac, Megan; Witkiewitz, Katie
2017-02-01
To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n=1726) and COMBINE (n=1383). In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pearson, Matthew R.; Bravo, Adrian J.; Kirouac, Megan; Witkiewitz, Katie
2017-01-01
Background To examine whether a clinically meaningful alcohol consumption cutoff can be created for clinical samples, we used receiver operator characteristic (ROC) curves to derive gender-specific consumption cutoffs that maximized sensitivity and specificity in the prediction of a wide range of negative consequences from drinking. Methods We conducted secondary data analyses using data from two large clinical trials targeting alcohol use disorders: Project MATCH (n = 1,726) and COMBINE (n = 1,383). Results In both studies, we found that the ideal cutoff for men and women that maximized sensitivity/specificity varied substantially both across different alcohol consumption variables and alcohol consequence outcomes. Further, the levels of sensitivity/specificity were poor across all consequences. Conclusions These results fail to provide support for a clinically meaningful alcohol consumption cutoff and suggest that binary classification of levels of alcohol consumption is a poor proxy for maximizing sensitivity/specificity in the prediction of negative consequences from drinking. Future research examining consumption-consequence associations should take advantage of continuous measures of alcohol consumption and alternative approaches for assessing the link between levels of consumption and consequences (e.g., ecological momentary assessment). Clinical researchers should consider focusing more directly on the consequences they aim to reduce instead of relying on consumption as a proxy for more clinically meaningful outcomes. PMID:28038361
Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J
2013-01-01
The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.
Hantavirus pulmonary syndrome clinical findings: evaluating a surveillance case definition.
Knust, Barbara; Macneil, Adam; Rollin, Pierre E
2012-05-01
Clinical cases of hantavirus pulmonary syndrome (HPS) can be challenging to differentiate from other acute respiratory diseases, which can lead to delays in diagnosis, treatment, and disease reporting. Rapid onset of severe disease occurs, at times before diagnostic test results are available. This study's objective was to examine the clinical characteristics of patients that would indicate HPS to aid in detection and reporting. Test results of blood samples from U.S. patients suspected of having HPS submitted to the Centers for Disease Control and Prevention from 1998-2010 were reviewed. Patient information collected by case report forms was compared between HPS-confirmed and test-negative patients. Diagnostic sensitivity, specificity, predictive values, and likelihood ratios were calculated for individual clinical findings and combinations of variables. Of 567 patients included, 36% were HPS-confirmed. Thrombocytopenia, chest x-rays with suggestive signs, and receiving supplemental oxygenation were highly sensitive (>95%), while elevated hematocrit was highly specific (83%) in detecting HPS. Combinations that maximized sensitivity required the presence of thrombocytopenia. Using a national sample of suspect patients, we found that thrombocytopenia was a highly sensitive indicator of HPS and should be included in surveillance definitions for suspected HPS. Using a sensitive suspect case definition to identify potential HPS patients that are confirmed by highly specific diagnostic testing will ensure accurate reporting of this disease.
Zhou, Zhiran; Zhang, Huitian; Lei, Yunxia
2016-10-01
To evaluate the diagnostic value of secreted frizzled-related protein 2 (SFRP2) gene promoter hypermethylation in stool for colorectal cancer (CRC). Open published diagnostic study of SFRP2 gene promoter hypermethylation in stool for CRC detection was electronic searched in the databases of PubMed, EMBASE, Cochrane Library, Web of Science, and China National Knowledge Infrastructure. The data of true positive, false positive false negative, and true negative identified by stool SFRP2 gene hypermethylation was extracted and pooled for diagnostic sensitivity, specificity, and summary receiver operating characteristic (SROC) curve. According to the inclusion and exclusion criteria, we finally included nine publications with 792 cases in the meta-analysis. Thus, the diagnostic sensitivity was aggregated through random effect model. The pooled sensitivity was 0.82 with the corresponding 95% confidence interval (95% CI) of 0.79-0.85; the pooled specificity and its corresponding 95% CI were 0.47 and 0.40-0.53 by the random effect model; we pooled the SROC curve by sensitivity versus specificity according to data published in the nine studies. The area under the SROC curve was 0.70 (95% CI: 0.65-0.73). SFRP2 gene promoter hypermethylation in stool can was a potential biomarker for CRC diagnosis with relative high sensitivity.
Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A
2017-01-01
Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.
Kee, C C; Jamaiyah, H; Geeta, A; Ali, Z Ahmad; Safiza, M N Noor; Suzana, S; Khor, G L; Rahmah, R; Jamalludin, A R; Sumarni, M G; Lim, K H; Faudzi, Y Ahmad; Amal, N M
2011-12-01
Generalised obesity and central obesity are risk factors for Type II diabetes mellitus and cardiovascular diseases. Waist circumference (WC) has been suggested as a single screening tool for identification of overweight or obese subjects in lieu of the body mass index (BMI) for weight management in public health program. Currently, the recommended waist circumference cut-off points of > or = 94cm for men and > or =80cm for women (waist action level 1) and > or = 102cm for men and > or = 88cm for women (waist action level 2) used for identification of overweight and obesity are based on studies in Caucasian populations. The objective of this study was to assess the sensitivity and specificity of the recommended waist action levels, and to determine optimal WC cut-off points for identification of overweight or obesity with central fat distribution based on BMI for Malaysian adults. Data from 32,773 subjects (14,982 men and 17,791 women) aged 18 and above who participated in the Third National Health Morbidity Survey in 2006 were analysed. Sensitivity and specificity of WC at waist action level 1 were 48.3% and 97.5% for men; and 84.2% and 80.6% for women when compared to the cut-off points based on BMI > or = 25kg/m2. At waist action level 2, sensitivity and specificity were 52.4% and 98.0% for men, and 79.2% and 85.4% for women when compared with the cut-off points based on BMI (> or = 30 kg/m2). Receiver operating characteristic analyses showed that the appropriatescreening cut-off points for WC to identify subjects with overweight (> or = 25kg/m2) was 86.0cm (sensitivity=83.6%, specificity=82.5%) for men, and 79.1cm (sensitivity=85.0%, specificity=79.5%) for women. Waist circumference cut-off points to identify obese subjects (BMI > or = 30 kg/m2) was 93.2cm (sensitivity=86.5%, specificity=85.7%) for men and 85.2cm (sensitivity=77.9%, specificity=78.0%) for women. Our findings demonstrated that the current recommended waist circumference cut-off points have low sensitivity for identification of overweight and obesity in men. We suggest that these newly identified cut-off points be considered.
Haines, H M; Pallant, J F; Fenwick, J; Gamble, J; Creedy, D K; Toohill, J; Hildingsson, I
2015-12-01
The WDEQ-A is the most widely used measure of childbirth fear in pregnant women; however there is increasing discussion in the literature that simpler, more culturally transferrable tools may offer a better solution to identifying fearful women in clinical practice. To compare the two item Fear of Birth Scale (FOBS) with the 33 item WDEQ-A in a large cohort of Australian pregnant women. Self-report questionnaires during second trimester including Wijma Delivery Expectancy Questionnaire (WDEQ-A) and Fear of Birth Scale (FOBS). Correlation of FOBS and WDEQ-A was tested using Spearman's correlation coefficients. Receiver operating characteristic (ROC) curve assessed the sensitivity and specificity of possible cut-points on the FOBS against WDEQ-A cut-point of ≥85. Sensitivity, specificity, positive and negative predictive values were determined. Fearful and non-fearful women as classified by both instruments were compared for differences in demographic, psycho-social and obstetric characteristics. 1410 women participated. The correlation between the instruments was strong (Spearman's Rho = 0.66, p < 0.001). The area under the ROC was 0.89 indicating high sensitivity with a FOBS cut-point of 54. Sensitivity was 89%, specificity 79% and Youden index 0.68. Positive predictive value was 85% and negative predictive value 79%. Both instruments identified high fear as significantly associated with first time mothers, previous emergency caesarean and women with self-reported anxiety and/or depression. Additionally FOBS identified a significant association between fearful women and preference for caesarean. This study supports the use of the FOBS in clinical practice to identify childbirth fear in pregnant women. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Portable Remote Imaging Spectrometer (PRISM): Laboratory and Field Calibration
NASA Technical Reports Server (NTRS)
Mouroulis, Pantazis; Van Gorp, Byron; Green, Robert O.; Eastwood, Michael; Boardman, Joseph; Richardson, Brandon S.; Rodriguez, Jose I.; Urquiza, Eugenio; Franklin, Brian D.; Gao, Bo-Cai
2012-01-01
We report the characteristics of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed for the challenges of coastal ocean research. PRISM has high signal to noise ratio and uniformity, as well as low polarization sensitivity. Acquisition of high quality data has been demonstrated with the first engineering flight.
An Efficient Method for Classifying Perfectionists
ERIC Educational Resources Information Center
Rice, Kenneth G.; Ashby, Jeffrey S.
2007-01-01
Multiple samples of university students (N = 1,537) completed the Almost Perfect Scale-Revised (APS-R; R. B. Slaney, M. Mobley, J. Trippi, J. Ashby, & D. G. Johnson, 1996). Cluster analyses, cross-validated discriminant function analyses, and receiver operating characteristic curves for sensitivity and specificity of APS-R scores were used to…
Criteria To Screen for Chronic Sinonasal Disease
Dixon, Anne E.; Sugar, Elizabeth A.; Zinreich, S. James; Slavin, Raymond G.; Corren, Jonathan; Naclerio, Robert M.; Ishii, Masaru; Cohen, Rubin I.; Brown, Ellen D.; Wise, Robert A.; Irvin, Charles G.
2009-01-01
Background: Sinusitis and rhinitis are associated with uncontrolled asthma. There are no simple, validated tools to screen for these diseases. The objective of this study was to assess instruments to assist in the diagnosis of chronic sinonasal disease. Methods: Participants without acute sinonasal symptoms underwent an extensive evaluation. The results were submitted to an expert panel that used the Delphi method to achieve consensus. Using the consensus diagnosis of the panel, we determined the sensitivity and specificity of test procedures to diagnose chronic sinonasal disease. We determined the reproducibility of the most sensitive and specific instrument in a separate cohort. Results: Fifty-nine participants were evaluated, and the expert panel reached consensus for all (42 participants with chronic sinonasal disease, 17 participants without chronic sinonasal disease). A six-item questionnaire based on the frequency of nasal symptoms was the most sensitive tool used to diagnose sinonasal disease (minimum specificity, 0.90). Reproducibility testing in a separate cohort of 63 participants (41 chronic sinonasal disease with asthma, 22 chronic sinonasal disease without asthma) showed a concordance correlation coefficient of 0.91 (95% CI, 0.85 to 0.94) when this questionnaire was limited to five items (ie, excluding a question on smell). This five-item questionnaire had a sensitivity of 0.90 (95% CI, 0.77 to 0.97), a specificity of 0.94 (95% CI, 0.71 to 1.00), and an area under the receiver operating characteristic curve of 0.97 (95% CI, 0.93 to 1.0). Sinus CT scans and nasal endoscopy lacked sensitivity for use in the diagnosis of chronic sinonasal disease. Conclusions: We have developed a sensitive, specific, and reproducible instrument to screen for chronic sinonasal disease. Validation studies of this five-item questionnaire are needed, including in patients with asthma. PMID:19581356
Wei, Zhenglun Alan; Trusty, Phillip M; Tree, Mike; Haggerty, Christopher M; Tang, Elaine; Fogel, Mark; Yoganathan, Ajit P
2017-01-04
Cardiovascular simulations have great potential as a clinical tool for planning and evaluating patient-specific treatment strategies for those suffering from congenital heart diseases, specifically Fontan patients. However, several bottlenecks have delayed wider deployment of the simulations for clinical use; the main obstacle is simulation cost. Currently, time-averaged clinical flow measurements are utilized as numerical boundary conditions (BCs) in order to reduce the computational power and time needed to offer surgical planning within a clinical time frame. Nevertheless, pulsatile blood flow is observed in vivo, and its significant impact on numerical simulations has been demonstrated. Therefore, it is imperative to carry out a comprehensive study analyzing the sensitivity of using time-averaged BCs. In this study, sensitivity is evaluated based on the discrepancies between hemodynamic metrics calculated using time-averaged and pulsatile BCs; smaller discrepancies indicate less sensitivity. The current study incorporates a comparison between 3D patient-specific CFD simulations using both the time-averaged and pulsatile BCs for 101 Fontan patients. The sensitivity analysis involves two clinically important hemodynamic metrics: hepatic flow distribution (HFD) and indexed power loss (iPL). Paired demographic group comparisons revealed that HFD sensitivity is significantly different between single and bilateral superior vena cava cohorts but no other demographic discrepancies were observed for HFD or iPL. Multivariate regression analyses show that the best predictors for sensitivity involve flow pulsatilities, time-averaged flow rates, and geometric characteristics of the Fontan connection. These predictors provide patient-specific guidelines to determine the effectiveness of analyzing patient-specific surgical options with time-averaged BCs within a clinical time frame. Copyright © 2016 Elsevier Ltd. All rights reserved.
Half-Unit Insulin Pens: Disease Management in Patients With Diabetes Who Are Sensitive to Insulin.
Klonoff, David C; Nayberg, Irina; Stauder, Udo; Oualali, Hamid; Domenger, Catherine
2017-05-01
Insulin pens represent a significant technological advancement in diabetes management. While the vast majority have been designed with 1U-dosing increments, improved accuracy and precision facilitated by half-unit increments may be particularly significant in specific patients who are sensitive to insulin. These include patients with low insulin requirements and in those requiring more precise dose adjustments, such as the pediatric patient population. This review summarized functional characteristics of insulin half-unit pens (HUPs) and their effect on user experience. The literature search was restricted to articles published in English between January 1, 2000, and January 1, 2015. A total of 17 publications met the set criteria and were included in the review. Overall, studies outlined characteristics for 4 insulin HUPs. Based on their functionality, the pens were generally similar and all met the ISO 11608-1 criteria for accuracy. However, some had specific advantageous features in terms of size, weight, design, dialing torque, and injection force. Although limited, the currently available user preference studies in children and adolescents with diabetes and their carers suggest that the selection of an HUP is likely to be influenced by a combination of factors such as these, in addition to the prescribed insulin and dosing regimen. Insulin HUPs are likely to be a key diabetes management tool for patients who are sensitive to insulin; specific pen features may further advance diabetes management in these populations.
Boehnke, Mitchell; Patel, Nayana; McKinney, Kristin; Clark, Toshimasa
The Society of Radiologists in Ultrasound (SRU 2005) and American Thyroid Association (ATA 2009 and ATA 2015) have published algorithms regarding thyroid nodule management. Kwak et al. and other groups have described models that estimate thyroid nodules' malignancy risk. The aim of our study is to use Kwak's model to evaluate the tradeoffs of both sensitivity and specificity of SRU 2005, ATA 2009 and ATA 2015 management algorithms. 1,000,000 thyroid nodules were modeled in MATLAB. Ultrasound characteristics were modeled after published data. Malignancy risk was estimated per Kwak's model and assigned as a binary variable. All nodules were then assessed using the published management algorithms. With the malignancy variable as condition positivity and algorithms' recommendation for FNA as test positivity, diagnostic performance was calculated. Modeled nodule characteristics mimic those of Kwak et al. 12.8% nodules were assigned as malignant (malignancy risk range of 2.0-98%). FNA was recommended for 41% of nodules by SRU 2005, 66% by ATA 2009, and 82% by ATA 2015. Sensitivity and specificity is significantly different (< 0.0001): 49% and 60% for SRU; 81% and 36% for ATA 2009; and 95% and 20% for ATA 2015. SRU 2005, ATA 2009 and ATA 2015 algorithms are used routinely in clinical practice to determine whether thyroid nodule biopsy is indicated. We demonstrate significant differences in these algorithms' diagnostic performance, which result in a compromise between sensitivity and specificity. Copyright © 2017 Elsevier Inc. All rights reserved.
Blood-based protein biomarkers for diagnosis of Alzheimer disease.
Doecke, James D; Laws, Simon M; Faux, Noel G; Wilson, William; Burnham, Samantha C; Lam, Chiou-Peng; Mondal, Alinda; Bedo, Justin; Bush, Ashley I; Brown, Belinda; De Ruyck, Karl; Ellis, Kathryn A; Fowler, Christopher; Gupta, Veer B; Head, Richard; Macaulay, S Lance; Pertile, Kelly; Rowe, Christopher C; Rembach, Alan; Rodrigues, Mark; Rumble, Rebecca; Szoeke, Cassandra; Taddei, Kevin; Taddei, Tania; Trounson, Brett; Ames, David; Masters, Colin L; Martins, Ralph N
2012-10-01
To identify plasma biomarkers for the diagnosis of Alzheimer disease (AD). Baseline plasma screening of 151 multiplexed analytes combined with targeted biomarker and clinical pathology data. General community-based, prospective, longitudinal study of aging. A total of 754 healthy individuals serving as controls and 207 participants with AD from the Australian Imaging Biomarker and Lifestyle study (AIBL) cohort with identified biomarkers that were validated in 58 healthy controls and 112 individuals with AD from the Alzheimer Disease Neuroimaging Initiative (ADNI) cohort. A biomarker panel was identified that included markers significantly increased (cortisol, pancreatic polypeptide, insulinlike growth factor binding protein 2, β(2) microglobulin, vascular cell adhesion molecule 1, carcinoembryonic antigen, matrix metalloprotein 2, CD40, macrophage inflammatory protein 1α, superoxide dismutase, and homocysteine) and decreased (apolipoprotein E, epidermal growth factor receptor, hemoglobin, calcium, zinc, interleukin 17, and albumin) in AD. Cross-validated accuracy measures from the AIBL cohort reached a mean (SD) of 85% (3.0%) for sensitivity and specificity and 93% (3.0) for the area under the receiver operating characteristic curve. A second validation using the ADNI cohort attained accuracy measures of 80% (3.0%) for sensitivity and specificity and 85% (3.0) for area under the receiver operating characteristic curve. This study identified a panel of plasma biomarkers that distinguish individuals with AD from cognitively healthy control subjects with high sensitivity and specificity. Cross-validation within the AIBL cohort and further validation within the ADNI cohort provides strong evidence that the identified biomarkers are important for AD diagnosis.
Wiglusz, Mariusz S; Landowski, Jerzy; Cubała, Wiesław J
2018-05-24
Anxiety disorders are frequent comorbid disorders in patients with epilepsy (PWEs). The availability of validated screening instruments to detect anxiety disorders in PWEs is limited. The aim of the present study was to validate the Polish version of the Hospital Anxiety and Depression Scale (HADS) in adult PWEs for the detection of anxiety disorders. A total of 96 outpatients with epilepsy completed the self-reported symptom scale, the HADS, and were diagnosed using the structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) axis I disorders (SCID-I). The sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), and receiver operating characteristic (ROC) curves were assessed to determine the optimal threshold scores for the HADS anxiety subscale (HADS-A). Receiver operating characteristic analyses showed areas under the curve at 80.8%. For diagnoses of anxiety disorder, the HADS-A demonstrated the best psychometric properties for a cutoff score ≥10 with sensitivity of 81.3%, specificity of 70.0%, PPV of 31.5%, and NPV of 94.9%. The HADS-A proved to be a valid and reliable psychometric instrument in terms of screening for anxiety disorders in our sample of PWEs. In the epilepsy setting, the HADS-A maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing anxiety disorders with an optimum cutoff score ≥10. Copyright © 2018 Elsevier Inc. All rights reserved.
Diagnosis of Tempromandibular Disorders Using Local Binary Patterns
Haghnegahdar, A.A.; Kolahi, S.; Khojastepour, L.; Tajeripour, F.
2018-01-01
Background: Temporomandibular joint disorder (TMD) might be manifested as structural changes in bone through modification, adaptation or direct destruction. We propose to use Local Binary Pattern (LBP) characteristics and histogram-oriented gradients on the recorded images as a diagnostic tool in TMD assessment. Material and Methods: CBCT images of 66 patients (132 joints) with TMD and 66 normal cases (132 joints) were collected and 2 coronal cut prepared from each condyle, although images were limited to head of mandibular condyle. In order to extract features of images, first we use LBP and then histogram of oriented gradients. To reduce dimensionality, the linear algebra Singular Value Decomposition (SVD) is applied to the feature vectors matrix of all images. For evaluation, we used K nearest neighbor (K-NN), Support Vector Machine, Naïve Bayesian and Random Forest classifiers. We used Receiver Operating Characteristic (ROC) to evaluate the hypothesis. Results: K nearest neighbor classifier achieves a very good accuracy (0.9242), moreover, it has desirable sensitivity (0.9470) and specificity (0.9015) results, when other classifiers have lower accuracy, sensitivity and specificity. Conclusion: We proposed a fully automatic approach to detect TMD using image processing techniques based on local binary patterns and feature extraction. K-NN has been the best classifier for our experiments in detecting patients from healthy individuals, by 92.42% accuracy, 94.70% sensitivity and 90.15% specificity. The proposed method can help automatically diagnose TMD at its initial stages. PMID:29732343
Wu, Xia; Li, Juan; Ayutyanont, Napatkamon; Protas, Hillary; Jagust, William; Fleisher, Adam; Reiman, Eric; Yao, Li; Chen, Kewei
2013-01-01
Given a single index, the receiver operational characteristic (ROC) curve analysis is routinely utilized for characterizing performances in distinguishing two conditions/groups in terms of sensitivity and specificity. Given the availability of multiple data sources (referred to as multi-indices), such as multimodal neuroimaging data sets, cognitive tests, and clinical ratings and genomic data in Alzheimer’s disease (AD) studies, the single-index-based ROC underutilizes all available information. For a long time, a number of algorithmic/analytic approaches combining multiple indices have been widely used to simultaneously incorporate multiple sources. In this study, we propose an alternative for combining multiple indices using logical operations, such as “AND,” “OR,” and “at least n” (where n is an integer), to construct multivariate ROC (multiV-ROC) and characterize the sensitivity and specificity statistically associated with the use of multiple indices. With and without the “leave-one-out” cross-validation, we used two data sets from AD studies to showcase the potentially increased sensitivity/specificity of the multiV-ROC in comparison to the single-index ROC and linear discriminant analysis (an analytic way of combining multi-indices). We conclude that, for the data sets we investigated, the proposed multiV-ROC approach is capable of providing a natural and practical alternative with improved classification accuracy as compared to univariate ROC and linear discriminant analysis.
Wu, Xia; Li, Juan; Ayutyanont, Napatkamon; Protas, Hillary; Jagust, William; Fleisher, Adam; Reiman, Eric; Yao, Li; Chen, Kewei
2014-01-01
Given a single index, the receiver operational characteristic (ROC) curve analysis is routinely utilized for characterizing performances in distinguishing two conditions/groups in terms of sensitivity and specificity. Given the availability of multiple data sources (referred to as multi-indices), such as multimodal neuroimaging data sets, cognitive tests, and clinical ratings and genomic data in Alzheimer’s disease (AD) studies, the single-index-based ROC underutilizes all available information. For a long time, a number of algorithmic/analytic approaches combining multiple indices have been widely used to simultaneously incorporate multiple sources. In this study, we propose an alternative for combining multiple indices using logical operations, such as “AND,” “OR,” and “at least n” (where n is an integer), to construct multivariate ROC (multiV-ROC) and characterize the sensitivity and specificity statistically associated with the use of multiple indices. With and without the “leave-one-out” cross-validation, we used two data sets from AD studies to showcase the potentially increased sensitivity/specificity of the multiV-ROC in comparison to the single-index ROC and linear discriminant analysis (an analytic way of combining multi-indices). We conclude that, for the data sets we investigated, the proposed multiV-ROC approach is capable of providing a natural and practical alternative with improved classification accuracy as compared to univariate ROC and linear discriminant analysis. PMID:23702553
Hu, Jian-bo; Zhou, Wei-hua; Hu, Shao-hua; Huang, Man-li; Wei, Ning; Qi, Hong-li; Huang, Jin-wen; Xu, Yi
2013-01-01
To evaluate the psychometric properties of the Chinese Montreal Cognitive Assessment (MoCA-C) and assess cross-cultural differences in a community-based cohort residing in the Eastern China. The study included 72 patients with Alzheimer's disease (AD), 84 patients with mild cognitive impairment (MCI) and 146 cognitively normal controls. Sensitivities and specificities were calculated using the recommended cut-off scores. Receiver operator characteristic (ROC) curve analyses were performed to determine optimal sensitivity and specificity. Criterion validity, inter-rater, test-retest reliability and internal consistencies of the MoCA-C were examined, and clinical observations made. The influence of age, education level and gender on MoCA score was examined. Using the recommended cut-off score of 26, the area under the ROC (AUC) for predicting MCI groups using the MoCA-C was 0.930 (95%CI: 0.894; 0.965). The MoCA-C demonstrated 92% sensitivity and 85% specificity in screening for MCI. Cultural differences from the original MoCA affected the test response rate. The MoCA-C appears to have utility as a cognitive screen for early detection of AD and for MCI and warrants further investigation regarding its applicability in primary care settings in elderly Chinese people. It will be necessary to revise the contents of the questionnaire to account for by local characteristics. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Narayanan, Deepa; Kalinyak, Judith E.; The, Juliette; Velasquez, Maria Victoria; Kahn, Simone; Saady, Matthew; Mahal, Ravinder; Chrystal, Larraine
2010-01-01
Purpose The objective of this study was to compare the performance characteristics of 18F-fluorodeoxyglucose (FDG) positron emission mammography (PEM) with breast magnetic resonance imaging (MRI) as a presurgical imaging and planning option for index and ipsilateral lesions in patients with newly diagnosed, biopsy-proven breast cancer. Methods Two hundred and eight women >25 years of age (median age = 59.7 ± 14.1 years) with biopsy-proven primary breast cancer enrolled in this prospective, single-site study. MRI, PEM, and whole-body positron emission tomography (WBPET) were conducted on each patient within 7 business days. PEM and WBPET images were acquired on the same day after intravenous administration of 370 MBq of FDG (median = 432.9 MBq). PEM and MRI images were blindly evaluated, compared with final surgical histopathology, and the sensitivity determined. Substudy analysis compared the sensitivity of PEM versus MRI in patients with different menopausal status, breast density, and use of hormone replacement therapy (HRT) as well as determination of performance characteristics for additional ipsilateral lesion detection. Results Two hundred and eight patients enrolled in the study of which 87% (182/208) were analyzable. Of these analyzable patients, 26.4% (48/182), 7.1% (13/182), and 64.2% (120/182) were pre-, peri-, and postmenopausal, respectively, and 48.4% (88/182) had extremely or heterogeneously dense breast tissue, while 33.5% (61/182) had a history of HRT use. Ninety-two percent (167/182) underwent core biopsy for index lesion diagnosis. Invasive cancer was found in 77.5% (141/182), while ductal carcinoma in situ (DCIS) and/or Paget’s disease were found in 22.5% (41/182) of patients. Both PEM and MRI had index lesion depiction sensitivity of 92.8% and both were significantly better than WBPET (67.9%, p < 0.001, McNemar’s test). For index lesions, PEM and MRI had equivalent sensitivity of various tumors, categorized by tumor stage as well as similar invasive tumor size predictions with Spearman's correlation coefficient of 0.61 for both PEM and MRI compared to surgical pathology. Menopausal status, breast density, and HRT did not influence the sensitivity of PEM or MRI. For 67 additional unsuspected ipsilateral lesions or multifocal lesions, PEM had sensitivity of 85% (34/40) and specificity of 74%, (20/27) compared to MRI's sensitivity of 98% (39/40) and specificity of 48% (13/27) [p = 0.074, for sensitivity; p = 0.096 for specificity] Conclusion PEM is a good alternative to MRI as a presurgical breast imaging option and its performance characteristics are not affected by patient menopausal/hormonal status or breast density. PMID:20871992
Schilling, Kathy; Narayanan, Deepa; Kalinyak, Judith E; The, Juliette; Velasquez, Maria Victoria; Kahn, Simone; Saady, Matthew; Mahal, Ravinder; Chrystal, Larraine
2011-01-01
The objective of this study was to compare the performance characteristics of (18)F-fluorodeoxyglucose (FDG) positron emission mammography (PEM) with breast magnetic resonance imaging (MRI) as a presurgical imaging and planning option for index and ipsilateral lesions in patients with newly diagnosed, biopsy-proven breast cancer. Two hundred and eight women >25 years of age (median age = 59.7 ± 14.1 years) with biopsy-proven primary breast cancer enrolled in this prospective, single-site study. MRI, PEM, and whole-body positron emission tomography (WBPET) were conducted on each patient within 7 business days. PEM and WBPET images were acquired on the same day after intravenous administration of 370 MBq of FDG (median = 432.9 MBq). PEM and MRI images were blindly evaluated, compared with final surgical histopathology, and the sensitivity determined. Substudy analysis compared the sensitivity of PEM versus MRI in patients with different menopausal status, breast density, and use of hormone replacement therapy (HRT) as well as determination of performance characteristics for additional ipsilateral lesion detection. Two hundred and eight patients enrolled in the study of which 87% (182/208) were analyzable. Of these analyzable patients, 26.4% (48/182), 7.1% (13/182), and 64.2% (120/182) were pre-, peri-, and postmenopausal, respectively, and 48.4% (88/182) had extremely or heterogeneously dense breast tissue, while 33.5% (61/182) had a history of HRT use. Ninety-two percent (167/182) underwent core biopsy for index lesion diagnosis. Invasive cancer was found in 77.5% (141/182), while ductal carcinoma in situ (DCIS) and/or Paget's disease were found in 22.5% (41/182) of patients. Both PEM and MRI had index lesion depiction sensitivity of 92.8% and both were significantly better than WBPET (67.9%, p < 0.001, McNemar's test). For index lesions, PEM and MRI had equivalent sensitivity of various tumors, categorized by tumor stage as well as similar invasive tumor size predictions with Spearman's correlation coefficient of 0.61 for both PEM and MRI compared to surgical pathology. Menopausal status, breast density, and HRT did not influence the sensitivity of PEM or MRI. For 67 additional unsuspected ipsilateral lesions or multifocal lesions, PEM had sensitivity of 85% (34/40) and specificity of 74%, (20/27) compared to MRI's sensitivity of 98% (39/40) and specificity of 48% (13/27) [p = 0.074, for sensitivity; p = 0.096 for specificity] PEM is a good alternative to MRI as a presurgical breast imaging option and its performance characteristics are not affected by patient menopausal/hormonal status or breast density.
Allergy to kiwi: is component-resolved diagnosis in routine clinical practice really impossible?
Asero, R
2012-04-01
Kiwi allergy is frequent and can be the result of sensitization to a number of allergens showing different physicochemical characteristics. Component-resolved diagnosis of kiwi allergy is still unavailable in routine clinical practice. To investigate whether component resolved-diagnosis of kiwi allergy can be, at least in part, carried out by a proper combination of routinely available diagnostic tools. 63 adults with plant food allergy were studied 36 were kiwi-allergic while 27 were kiwi-tolerant and served as controls. Patients and controls underwent SPT with commercial peach and kiwi extracts, and with aprofilin-enriched date palm pollen extract (all by ALK-Abellò), and the measurement of IgE to birch, kiwi, and natural rubber latex. The in-vitro test showed poor sensitivity and specificity, as it scored positive in about 50% of patients and controls irrespective of clinical allergy to kiwi. The kiwi SPT showed overall poor sensitivity; however, it scored negative in all subjects with pollen food-allergy syndrome, was weakly positive in some lipid transfer protein-hypersensitive/kiwi tolerant subjects and in one latex-sensitized subject, and strongly positive in all subjects with primary kiwi sensitization. SPT with this commercial kiwi extract sensitively and specifically detects patients reacting to specific kiwi allergens. This can be useful to detect patients that are at risk of potentially severe reactions, particularly in case of co-sensitization to labile allergens, while we wait that the whole spectrum of kiwi allergens becomes available for routine in-vitro testing.
[Insect cholinesterases and irreversible inhibitors. Statistical treatment of the data].
Moralev, S N
2010-01-01
The data on sensitivity of cholinesterases (ChE) of different insects to reversible inhibitors, as well as the data on physico-chemical parameters of amino acids constituting their active centers, were treated by factor analysis and juxtaposed. It is shown that both these characteristics are related to taxonomical belonging of insects. It is revealed the "material substrate" of the factors determining inhibitor action specificity, which are specific sites in ChE active center.
Correcting the anion gap for hypoalbuminaemia does not improve detection of hyperlactataemia
Dinh, C H; Ng, R; Grandinetti, A; Joffe, A; Chow, D C
2006-01-01
Background An elevated lactate level reflects impaired tissue oxygenation and is a predictor of mortality. Studies have shown that the anion gap is inadequate as a screen for hyperlactataemia, particularly in critically ill and trauma patients. A proposed explanation for the anion gap's poor sensitivity and specificity in detecting hyperlactataemia is that the serum albumin is frequently low. This study therefore, sought to compare the predictive values of the anion gap and the anion gap corrected for albumin (cAG) as an indicator of hyperlactataemia as defined by a lactate ⩾2.5 mmol/l. Methods A retrospective review of 639 sets of laboratory values from a tertiary care hospital. Patients' laboratory results were included in the study if serum chemistries and lactate were drawn consecutively. The sensitivity, specificity, and predictive values were obtained. A receiver operator characteristics curve (ROC) was drawn and the area under the curve (AUC) was calculated. Results An anion gap ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 39%, 89%, 79%, and 58%, respectively, and a cAG ⩾12 provided a sensitivity, specificity, positive predictive value, and negative predictive value of 75%, 59%, 66%, and 69%, respectively. The ROC curves between anion gap and cAG as a predictor of hyperlactataemia were almost identical. The AUC was 0.757 and 0.750, respectively. Conclusions The sensitivities, specificities, and predictive values of the anion gap and cAG were inadequate in predicting the presence of hyperlactataemia. The cAG provides no additional advantage over the anion gap in the detection of hyperlactataemia. PMID:16858097
Theurer, M E; White, B J; Larson, R L; Schroeder, T C
2015-03-01
Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (<15%) and high (≥15%) groups. For both apparent prevalence categories, increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.
Hill, Emily; Bleck, Thomas P; Singh, Kamaljit; Ouyang, Bichun; Busl, Katharina M
2017-06-01
In a febrile patient with a ventriculostomy, diagnosing or excluding bacterial or microbial ventriculitis is difficult, as conventional markers in analysis of cerebrospinal fluid (CSF) are not applicable due to presence of blood and inflammation. CSF lactate has been shown to be a useful indicator of bacterial meningitis in CSF obtained via lumbar puncture, but little and heterogenous data exist on patients with ventriculostomies. We reviewed all CSF analyses obtained via ventriculostomy in patients admitted to our tertiary medical center between 2008 and 2013, and constructed receiver operating characteristic (ROC) curves to evaluate the accuracy of CSF lactate concentration in discriminating a positive CSF culture from a negative one in setting of ventriculostomy and prophylactic antibiosis. Among 467 CSF lactate values, there were 22 corresponding CSF cultures with bacterial growth. Sensitivities and specificities for CSF lactate at threshold values 3, 4, 5 and 6mmol/L showed sensitivity and specificity greater than 70% for CSF lactate threshold 4mmol/L. The lowest threshold value of 3mmol/L resulted in higher sensitivity of 81.8%, and the highest chosen threshold value resulted in high specificity of 94.2%, but these values had poor corresponding specificity and sensitivity, respectively. The area under the curve was 0.82 (95% CI 0.72, 0.91). Our data from a large sample of CSF studies in patients with ventriculostomy indicate that no single value of CSF lactate provided both sensitivity and specificity high enough to be regarded as reliable test. Copyright © 2017 Elsevier B.V. All rights reserved.
2012-01-01
Background The aspartate aminotransferase-to-platelet ratio index (APRI), a tool with limited expense and widespread availability, is a promising noninvasive alternative to liver biopsy for detecting hepatic fibrosis. The objective of this study was to systematically review the performance of the APRI in predicting significant fibrosis and cirrhosis in hepatitis B-related fibrosis. Methods Areas under summary receiver operating characteristic curves (AUROC), sensitivity and specificity were used to examine the accuracy of the APRI for the diagnosis of hepatitis B-related significant fibrosis and cirrhosis. Heterogeneity was explored using meta-regression. Results Nine studies were included in this meta-analysis (n = 1,798). Prevalence of significant fibrosis and cirrhosis were 53.1% and 13.5%, respectively. The summary AUCs of the APRI for significant fibrosis and cirrhosis were 0.79 and 0.75, respectively. For significant fibrosis, an APRI threshold of 0.5 was 84% sensitive and 41% specific. At the cutoff of 1.5, the summary sensitivity and specificity were 49% and 84%, respectively. For cirrhosis, an APRI threshold of 1.0-1.5 was 54% sensitive and 78% specific. At the cutoff of 2.0, the summary sensitivity and specificity were 28% and 87%, respectively. Meta-regression analysis indicated that the APRI accuracy for both significant fibrosis and cirrhosis was affected by histological classification systems, but not influenced by the interval between Biopsy & APRI or blind biopsy. Conclusion Our meta-analysis suggests that APRI show limited value in identifying hepatitis B-related significant fibrosis and cirrhosis. PMID:22333407
NASA Astrophysics Data System (ADS)
Futia, Gregory L.; Qamar, Lubna; Behbakht, Kian; Gibson, Emily A.
2016-04-01
Circulating tumor cell (CTC) identification has applications in both early detection and monitoring of solid cancers. The rarity of CTCs, expected at ~1-50 CTCs per million nucleated blood cells (WBCs), requires identifying methods based on biomarkers with high sensitivity and specificity for accurate identification. Discovery of biomarkers with ever higher sensitivity and specificity to CTCs is always desirable to potentially find more CTCs in cancer patients thus increasing their clinical utility. Here, we investigate quantitative image cytometry measurements of lipids with the biomarker panel of DNA, Cytokeratin (CK), and CD45 commonly used to identify CTCs. We engineered a device for labeling suspended cell samples with fluorescent antibodies and dyes. We used it to prepare samples for 4 channel confocal laser scanning microscopy. The total data acquired at high resolution from one sample is ~ 1.3 GB. We developed software to perform the automated segmentation of these images into regions of interest (ROIs) containing individual cells. We quantified image features of total signal, spatial second moment, spatial frequency second moment, and their product for each ROI. We performed measurements on pure WBCs, cancer cell line MCF7 and mixed samples. Multivariable regressions and feature selection were used to determine combination features that are more sensitive and specific than any individual feature separately. We also demonstrate that computation of spatial characteristics provides higher sensitivity and specificity than intensity alone. Statistical models allowed quantification of the required sensitivity and specificity for detecting small levels of CTCs in a human blood sample.
Effectiveness of Computer-Aided Detection in Community Mammography Practice
Abraham, Linn; Taplin, Stephen H.; Geller, Berta M.; Carney, Patricia A.; D’Orsi, Carl; Elmore, Joann G.; Barlow, William E.
2011-01-01
Background Computer-aided detection (CAD) is applied during screening mammography for millions of US women annually, although it is uncertain whether CAD improves breast cancer detection when used by community radiologists. Methods We investigated the association between CAD use during film-screen screening mammography and specificity, sensitivity, positive predictive value, cancer detection rates, and prognostic characteristics of breast cancers (stage, size, and node involvement). Records from 684 956 women who received more than 1.6 million film-screen mammograms at Breast Cancer Surveillance Consortium facilities in seven states in the United States from 1998 to 2006 were analyzed. We used random-effects logistic regression to estimate associations between CAD and specificity (true-negative examinations among women without breast cancer), sensitivity (true-positive examinations among women with breast cancer diagnosed within 1 year of mammography), and positive predictive value (breast cancer diagnosed after positive mammograms) while adjusting for mammography registry, patient age, time since previous mammography, breast density, use of hormone replacement therapy, and year of examination (1998–2002 vs 2003–2006). All statistical tests were two-sided. Results Of 90 total facilities, 25 (27.8%) adopted CAD and used it for an average of 27.5 study months. In adjusted analyses, CAD use was associated with statistically significantly lower specificity (OR = 0.87, 95% confidence interval [CI] = 0.85 to 0.89, P < .001) and positive predictive value (OR = 0.89, 95% CI = 0.80 to 0.99, P = .03). A non-statistically significant increase in overall sensitivity with CAD (OR = 1.06, 95% CI = 0.84 to 1.33, P = .62) was attributed to increased sensitivity for ductal carcinoma in situ (OR = 1.55, 95% CI = 0.83 to 2.91; P = .17), although sensitivity for invasive cancer was similar with or without CAD (OR = 0.96, 95% CI = 0.75 to 1.24; P = .77). CAD was not associated with higher breast cancer detection rates or more favorable stage, size, or lymph node status of invasive breast cancer. Conclusion CAD use during film-screen screening mammography in the United States is associated with decreased specificity but not with improvement in the detection rate or prognostic characteristics of invasive breast cancer. PMID:21795668
Girman, Cynthia J; Faries, Douglas; Ryan, Patrick; Rotelli, Matt; Belger, Mark; Binkowitz, Bruce; O'Neill, Robert
2014-05-01
The use of healthcare databases for comparative effectiveness research (CER) is increasing exponentially despite its challenges. Researchers must understand their data source and whether outcomes, exposures and confounding factors are captured sufficiently to address the research question. They must also assess whether bias and confounding can be adequately minimized. Many study design characteristics may impact on the results; however, minimal if any sensitivity analyses are typically conducted, and those performed are post hoc. We propose pre-study steps for CER feasibility assessment and to identify sensitivity analyses that might be most important to pre-specify to help ensure that CER produces valid interpretable results.
Nagata, Satoshi; Hamada, Tomofumi; Yamada, Norishige; Yokoyama, Seiya; Kitamoto, Sho; Kanmura, Yuji; Nomura, Masahiro; Kamikawa, Yoshiaki; Yonezawa, Suguru; Sugihara, Kazumasa
2012-09-01
The early detection of oral squamous cell carcinoma (OSCC) is important, and a screening test with high sensitivity and specificity is urgently needed. Therefore, in this study, the authors investigated the methylation status of tumor-related genes with the objective of establishing a noninvasive method for the detection of OSCC. Oral rinse samples were obtained from 34 patients with OSCC and from 24 healthy individuals (controls). The methylation status of 13 genes was determined by using methylation-specific polymerase chain reaction analysis and was quantified using a microchip electrophoresis system. Promoter methylation in each participant was screened by receiver operating characteristic analysis, and the utility of each gene's methylation status, alone and in combination with other genes, was evaluated as a tool for oral cancer detection. Eight of the 13 genes had significantly higher levels of DNA methylation in samples from patients with OSCC than in controls. The genes E-cadherin (ECAD), transmembrane protein with epidermal growth factor-like and 2 follistatin-like domains 2 (TMEFF2), retinoic acid receptor beta (RARβ), and O-6 methylguanine DNA methyltransferase (MGMT) had high sensitivity (>75%) and specificity for the detection of oral cancer. OSCC was detected with 100% sensitivity and 87.5% specificity using a combination of ECAD, TMEFF2, RARβ, and MGMT and with 97.1% sensitivity and 91.7% specificity using a combination of ECAD, TMEFF2, and MGMT. The aberrant methylation of a combination of marker genes present in oral rinse samples was used to detect OSCC with >90% sensitivity and specificity. The detection of methylated marker genes from oral rinse samples has great potential for the noninvasive detection of OSCC. Copyright © 2012 American Cancer Society.
Sethi, Saurabh; Simonetto, Douglas A; Abdelmoneim, Soha S; Campion, Michael B; Kaloiani, Irakli; Clayton, Amy C; Kremers, Walter K; Halling, Kevin C; Kamath, Patrick S; Talwalkar, Jayant; Shah, Vijay H
2012-01-01
Background/Objectives Circulating endothelial cells (CECs) are indicative of vascular injury and correlate with severity of vascular diseases. A pilot study showed that the ratio of CEC to platelet count (CEC/PC) was effective in predicting cirrhosis. Therefore, we evaluated CEC/PC in a larger cohort of patients, correlated it with cirrhosis, and compared its operating characteristics with previously described biomarker for cirrhosis, the AST/platelet ratio index (APRI). Methods Fifty-three patients with cirrhosis, 20 matched healthy controls, and 9 patients with noncirrhotic liver disease were recruited. Peripheral blood sample was collected and analyzed to enumerate nucleated CEC CD146+, CD105+, CD45– using a commercial assay. Results Median CEC counts were significantly higher in patients with cirrhosis (62 cells/4 mL, interquartile range [IQR]: 43.5–121) as compared with controls (31 cells/4 mL, IQR: 22.2–40). The CEC/PC was also significantly elevated in cirrhotics (0.69, IQR: 0.39–1.48) compared with controls (0.12, IQR: 0.09–0.20) and noncirrhotics (0.21, IQR: 0.08–0.43). Receiver operator characteristic (ROC) analysis revealed that CEC cutoff value of ≥37 cells/4 mL showed sensitivity of 81% and specificity of 75% for differentiating cirrhosis from controls (area under the curve [AUC]: 0.80; 95% confidence interval [CI] 0.67–0.91). The CEC/PC ratio cutoff value of ≥0.23 showed sensitivity of 91% and specificity of 82% (AUC: 0.92; 95% CI 0.83–0.99). The APRI cutoff value of ≥0.4 showed sensitivity of 94% and specificity of 85% for differentiating cirrhosis from control patients (AUC: 0.96; 95% CI 0.90–1.0). A product of CEC and APRI, termed CAPRI (CEC-APRI), effectively distinguished patients with cirrhosis from controls; with cutoff value of ≥12.7, showing higher sensitivity of 98% and specificity of 85% (AUC: 0.98; 95% CI 0.96–1.0). Conclusion The CEC/PC ratio is significantly elevated in patients with cirrhosis and demonstrates comparable operating characteristics to previously described APRI. Furthermore, CAPRI, compiled as product of CEC to APRI showed outstanding ability to distinguish patients with cirrhosis from controls, although larger studies are necessary for validation. PMID:25755402
Ma, Wei-Fen; Wu, Po-Lun; Yang, Shu-Ju; Cheng, Kuang-Fu; Chiu, Hsien-Tsai; Lane, Hsien-Yuan
2010-12-01
Early interventions can improve treatment outcomes for individuals with major psychiatric disorders and with nonspecific symptoms but increasingly impaired cognitive perception, emotions, and behaviour. One way used to identify people susceptible to psychosis is through the schizotypal personality trait. Persons with schizotypal characteristics have been identified with the widely used Schizotypal Personality Questionnaire-Brief. However, no suitable instruments are available to screen individuals in the Taiwanese population for evidence of early psychotic symptoms. The purpose of this study was to test the sensitivity and specificity of the Chinese version of the Schizotypal Personality Questionnaire-Brief for identifying undergraduate students' susceptibility to psychosis. Two-stage, cross-sectional survey design. The self-administered scale was tested in a convenience sample of 618 undergraduate students at a medical university in Taiwan. Among these students, 54 completed the scale 2 weeks apart for test-retest reliability, and 80 were tested to identify their susceptibility to psychosis. In Stage I, participants with scores in the top 6.5% were classified as the high-score group (n=40). The control group (n=40) was randomly selected from the remaining participants with scores <15 and matched by gender. These 80 students were asked to participate in psychiatric interviews in Stage II. The instrument was tested for reliability using intraclass correlation coefficients and the Kuder-Richardson formula 20. The instrument was analysed for optimal sensitivity and specificity using odds-ratio analysis and receiver operating characteristic curves. The 22-item Chinese version of the Schizotypal Personality Questionnaire-Brief had a 2-week test-retest reliability of 0.82 and internal consistency of 0.76. The optimal cut-off score was 17, with odds ratios of 24.4 and an area under the receiver operating characteristic curves of 0.83. The instrument had a sensitivity of 80.0% and specificity of 85.9% in identifying undergraduate students' susceptibility to psychosis. The Chinese version Schizotypal Personality Questionnaire-Brief is a reliable instrument, but should not be used as a screening tool until its psychometric properties have been evaluated in more detail. Other screening tools need to be used in future studies with the CSPQ-B to improve the accuracy of identifying susceptibility to psychosis among young adults. Copyright © 2010. Published by Elsevier Ltd.
Brawer, M K; Cheli, C D; Neaman, I E; Goldblatt, J; Smith, C; Schwartz, M K; Bruzek, D J; Morris, D L; Sokoll, L J; Chan, D W; Yeung, K K; Partin, A W; Allard, W J
2000-05-01
Determining serum total prostate specific antigen (PSA) has proved to be a valuable diagnostic aid for detecting prostatic carcinoma, although the lack of specificity has limited its usefulness. Studies indicate that the use of percent free PSA would improve specificity while maintaining sensitivity. Since complexed PSA represents the major proportion of measurable PSA in serum, we determined whether it represents a single test alternative to the use of percent free PSA for the early detection of prostate cancer. Archival serum was obtained from 385 men with no evidence of malignancy on biopsy and 272 with biopsy confirmed prostate cancer. We determined the concentration and proportion of total, complexed and free PSA. Receiver operating characteristics analysis using total PSA results from all samples (range 0.32 to 117 ng./ml.) indicated that the areas under the curve for complexed PSA alone as well as the free-to-total and complexed-to-total PSA ratios were similar and significantly greater than those for total PSA alone. Within the range of 85% to 95% sensitivity receiver operating characteristics analysis revealed that the specificity of complexed PSA was higher than that of total PSA and equivalent to that of the free-to-total PSA ratio. We noted a similar improvement in specificity in the 4 to 10 ng./ml. total PSA range. Using published cutoff values for complexed, total and percent free PSA when total PSA was in the 4 to 10 ng./ml. range the sensitivity and specificity of complexed and percent free PSA were similar. Within the 4 to 10 ng./ml. total PSA range the population of patients with no evidence of malignancy and complexed PSA below the upper limit was different with respect to total PSA from that with no evidence of malignancy and free PSA greater than 25%. The measurement of complexed PSA represents an alternative to the use of percent free PSA, although the patient populations identified by the 2 tests are different.
Uhr, Jonathan W.; Salvin, S. B.; Pappenheimer, A. M.
1957-01-01
A general method for induction of the delayed hypersensitive state directed against single protein antigens is described. The method consists of intradermal injection of minute amounts of washed immune precipitates containing the antigen in question. Provided the specific precipitates are formed in the region of antibody excess, maximal sensitivity develops at least 2 to 3 weeks before detectable circulating antibody is formed in guinea pigs against the sensitizing antigen. Neither adjuvant nor killed acid-fast bacteria are required for induction of the delayed hypersensitive state although the degree of sensitization is considerably increased when the sensitizing material is incorporated in Freund's complete adjuvant. Characteristics of the "delayed" as opposed to the "immediate" hypersensitive states in the guinea pig are described and implications of the findings are discussed. PMID:13385403
NASA Astrophysics Data System (ADS)
Ganesan, A.; Alakhras, M.; Brennan, P. C.; Lee, W.; Tapia, K.; Mello-Thoms, C.
2018-03-01
Purpose: To determine the impact of Breast Screen Reader Assessment Strategy (BREAST) over time in improving radiologists' breast cancer detection performance, and to identify the group of radiologists that benefit the most by using BREAST as a training tool. Materials and Methods: Thirty-six radiologists who completed three case-sets offered by BREAST were included in this study. The case-sets were arranged in radiologists' chronological order of completion and five performance measures (sensitivity, specificity, location sensitivity, receiver operating characteristics area under the curve (ROC AUC) and jackknife alternative free-response receiver operating characteristic (JAFROC) figure-of-merit (FOM)), available from BREAST, were compared between case-sets to determine the level of improvement achieved. The radiologists were then grouped based on their characteristics and the above performance measures between the case-sets were compared. Paired t-tests or Wilcoxon signed-rank tests with statistical significance set at p < 0.05 were used to compare the performance measures. Results: Significant improvement was demonstrated in radiologists' case-set performance in terms of location sensitivity and JAFROC FOM over the years, and radiologists' location sensitivity and JAFROC FOM showed significant improvement irrespective of their characteristics. In terms of ROC AUC, significant improvement was shown for radiologists who were reading screen mammograms for more than 7 years and spent more than 9 hours per week reading mammograms. Conclusion: Engaging with case-sets appears to enhance radiologists' performance suggesting the important value of initiatives such as BREAST. However, such performance enhancement was not shown for everyone, highlighting the need to tailor the BREAST platform to benefit all radiologists.
Ma, Chunming; Liu, Yue; Lu, Qiang; Lu, Na; Liu, Xiaoli; Tian, Yiming; Wang, Rui; Yin, Fuzai
2016-02-01
The blood pressure-to-height ratio (BPHR) has been shown to be an accurate index for screening hypertension in children and adolescents. The aim of the present study was to perform a meta-analysis to assess the performance of BPHR for the assessment of hypertension. Electronic and manual searches were performed to identify studies of the BPHR. After methodological quality assessment and data extraction, pooled estimates of the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, area under the receiver operating characteristic curve and summary receiver operating characteristics were assessed systematically. The extent of heterogeneity for it was assessed. Six studies were identified for analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio values of BPHR, for assessment of hypertension, were 96% [95% confidence interval (CI)=0.95-0.97], 90% (95% CI=0.90-0.91), 10.68 (95% CI=8.03-14.21), 0.04 (95% CI=0.03-0.07) and 247.82 (95% CI=114.50-536.34), respectively. The area under the receiver operating characteristic curve was 0.9472. The BPHR had higher diagnostic accuracies for identifying hypertension in children and adolescents.
Chang, G.; Ruehl, K.; Jones, C. A.; ...
2015-12-24
Modeled nearshore wave propagation was investigated downstream of simulated wave energy converters (WECs) to evaluate overall near- and far-field effects of WEC arrays. Model sensitivity to WEC characteristics and WEC array deployment scenarios was evaluated using a modified version of an industry standard wave model, Simulating WAves Nearshore (SWAN), which allows the incorporation of device-specific WEC characteristics to specify obstacle transmission. The sensitivity study illustrated that WEC device type and subsequently its size directly resulted in wave height variations in the lee of the WEC array. Wave heights decreased up to 30% between modeled scenarios with and without WECs formore » large arrays (100 devices) of relatively sizable devices (26 m in diameter) with peak power generation near to the modeled incident wave height. Other WEC types resulted in less than 15% differences in modeled wave height with and without WECs, with lesser influence for WECs less than 10 m in diameter. Wave directions and periods were largely insensitive to changes in parameters. Furthermore, additional model parameterization and analysis are required to fully explore the model sensitivity of peak wave period and mean wave direction to the varying of the parameters.« less
A new D-dimer cutoff in bedridden hospitalized elderly patients.
Granziera, Serena; Rechichi, Alfonsina; De Rui, Marina; De Carlo, Paola; Bertozzo, Giulia; Marigo, Lucia; Nante, Giovanni; Manzato, Enzo
2013-03-01
Asymptomatic deep vein thrombosis (DVT) and pulmonary embolism are leading causes of morbidity following the hospitalization of elderly people. The diagnosis of DVT is supported by the D-dimer laboratory assay. The concentration of D-dimer increases in patients with DVT, but may be high in other conditions too (i.e. cancer, infections and inflammation). Old age coincides with a physiological increase in D-dimer values, and that is why D-dimer assay in the elderly is characteristically highly sensitive but scarcely specific. The aim of our study was to explore the reliability of different D-dimer cutoffs for the diagnosis of asymptomatic DVT in a population of bedridden hospitalized elderly patients. We studied 199 patients who were a mean 86.3 ± 6.7 years old. All participants underwent lower limb Doppler ultrasound (DUS) and D-dimer venous blood sampling on admission. In our cohort, the usual cutoff proved highly sensitive (100%), but its specificity was very poor (20.1%). To find a higher cutoff that could improve the method's specificity, we analyzed our data using a receiver operating characteristic curve analysis. The resulting D-dimer cutoff of 492 μg/l enabled us to retain the same sensitivity while improving the test's specificity to 39.1%, with a consequent improvement in its positive predictive value and accuracy. In addition to improving the method's reliability, this result may be helpful in clinical practice, in both medical wards and nursing homes. By adopting a cutoff of 492 μg/l, clinicians could significantly increase the proportion of older patients in whom DVT can be safely ruled out, reducing referrals for DUS and administration of heparin, with consequent clinical, practical and economic advantages.
Attallah, Abdelfattah M.; Bughdadi, Faisal A.; El-Shazly, Atef M.
2013-01-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P < 0.0001) for discriminating Fasciola-infected and noninfected individuals. The developed assay showed high degrees of sensitivity, specificity, and efficiency (>93%), and a significant correlation (r = 0.715, P < 0.0001) between antigen level and parasite egg count was shown. In conclusion, a 27-kDa Fasciola antigen was identified in sera of F. gigantica-infected individuals. A highly sensitive and specific Fasciola antigen detection assay, FgCA-27 ELISA, was developed for laboratory diagnosis of human fascioliasis. PMID:23945158
Attallah, Abdelfattah M; Bughdadi, Faisal A; El-Shazly, Atef M; Ismail, Hisham
2013-10-01
Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P < 0.0001) for discriminating Fasciola-infected and noninfected individuals. The developed assay showed high degrees of sensitivity, specificity, and efficiency (>93%), and a significant correlation (r = 0.715, P < 0.0001) between antigen level and parasite egg count was shown. In conclusion, a 27-kDa Fasciola antigen was identified in sera of F. gigantica-infected individuals. A highly sensitive and specific Fasciola antigen detection assay, FgCA-27 ELISA, was developed for laboratory diagnosis of human fascioliasis.
Quantitative Ultrasound for Measuring Obstructive Severity in Children with Hydronephrosis.
Cerrolaza, Juan J; Peters, Craig A; Martin, Aaron D; Myers, Emmarie; Safdar, Nabile; Linguraru, Marius George
2016-04-01
We define sonographic biomarkers for hydronephrotic renal units that can predict the necessity of diuretic nuclear renography. We selected a cohort of 50 consecutive patients with hydronephrosis of varying severity in whom 2-dimensional sonography and diuretic mercaptoacetyltriglycine renography had been performed. A total of 131 morphological parameters were computed using quantitative image analysis algorithms. Machine learning techniques were then applied to identify ultrasound based safety thresholds that agreed with the t½ for washout. A best fit model was then derived for each threshold level of t½ that would be clinically relevant at 20, 30 and 40 minutes. Receiver operating characteristic curve analysis was performed. Sensitivity, specificity and area under the receiver operating characteristic curve were determined. Improvement obtained by the quantitative imaging method compared to the Society for Fetal Urology grading system and the hydronephrosis index was statistically verified. For the 3 thresholds considered and at 100% sensitivity the specificities of the quantitative imaging method were 94%, 70% and 74%, respectively. Corresponding area under the receiver operating characteristic curve values were 0.98, 0.94 and 0.94, respectively. Improvement obtained by the quantitative imaging method over the Society for Fetal Urology grade and hydronephrosis index was statistically significant (p <0.05 in all cases). Quantitative imaging analysis of renal sonograms in children with hydronephrosis can identify thresholds of clinically significant washout times with 100% sensitivity to decrease the number of diuretic renograms in up to 62% of children. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Niederhauser, Blake D; Spinner, Robert J; Jentoft, Mark E; Everist, Brian M; Matsumoto, Jane M; Amrami, Kimberly K
2013-04-01
To describe imaging characteristics of neuromuscular choristomas (NMC) and to differentiate them from fibrolipomatous hamartomas (FLH). Clinical and imaging characteristics of six patients with biopsy-proven NMC and six patients with FLH were reviewed by musculoskeletal, a pediatric, and two in-training radiologists with a literature review to define typical magnetic resonance imaging features by consensus. Five radiology trainees blinded to cases and naive to the diagnosis of NMC and a musculoskeletal-trained radiologist rated each lesion as having more than or less than 50% intralesional fat, as well as an overall impression using axial T1 images. Sensitivity, specificity, accuracy, and interobserver agreement kappa were determined. Typical features of NMC include smoothly tapering, fusiform enlargement of the sciatic nerve or brachial plexus elements with T1 and T2 signal characteristics closely following those of muscle. Longitudinal bands of intervening low T1 and T2 signal were often present and likely corresponded to fibrous tissue by pathology. Four of five patients with long-term follow-up (80%) developed aggressive fibromatosis after percutaneous or surgical biopsy. Nerve fascicle thickening often resulted in a "coaxial cable" appearance similar to classic FLH, however, using a cutoff of <50% intralesional fat allowed for differentiation with 100% sensitivity by all reviewers and 100% specificity when all imaging features were utilized for impressions. Agreement was excellent with all differentiating methods (kappa 0.861-1.0). NMC can be confidently differentiated from FLH and malignancies using characteristic imaging and clinical features. When a diagnosis is made, biopsy should be avoided given frequent complication by aggressive fibromatosis.
Keiderling, Timothy A
2017-12-01
Isotope labeling has a long history in chemistry as a tool for probing structure, offering enhanced sensitivity, or enabling site selection with a wide range of spectroscopic tools. Chirality sensitive methods such as electronic circular dichroism are global structural tools and have intrinsically low resolution. Consequently, they are generally insensitive to modifications to enhance site selectivity. The use of isotope labeling to modify vibrational spectra with unique resolvable frequency shifts can provide useful site-specific sensitivity, and these methods have been recently more widely expanded in biopolymer studies. While the spectral shifts resulting from changes in isotopic mass can provide resolution of modes from specific parts of the molecule and can allow detection of local change in structure with perturbation, these shifts alone do not directly indicate structure or chirality. With vibrational circular dichroism (VCD), the shifted bands and their resultant sign patterns can be used to indicate local conformations in labeled biopolymers, particularly if multiple labels are used and if their coupling is theoretically modeled. This mini-review discusses selected examples of the use of labeling specific amides in peptides to develop local structural insight with VCD spectra. © 2017 Wiley Periodicals, Inc.
Mirrakhimov, Aibek E; Lunegova, Olga S; Kerimkulova, Alina S; Moldokeeva, Cholpon B; Nabiev, Malik P; Mirrakhimov, Erkin M
2012-02-22
People of different racial and ethnic backgrounds have a distinct pattern of central fat deposition, thus making it necessary to devise a race based approach for the diagnosis and evaluation of abdominal obesity (AO). This is the first study to determine the optimal waist circumference (WC) cutoff values for definition of AO in an ethnic Kyrgyz population. 323 persons of Kyrgyz ethnicity (183 women and 140 men), with a mean age of 51.8 ± 9.5 years old were included in the study. Measurement of blood pressure (BP), anthropometric data (including body mass index calculation and WC measurement), fasting blood sugar, serum lipid parameters and insulin were performed in all examined individuals. Insulin resistance (IR) was considered as HOMA index (insulin × fasting glucose/22.5) ≥ 2.77. Sensitivity and specificity for the presence of IR or two other criteria of MS (according to the international classification, 2009) were calculated by using receiver operating characteristic (ROC) curves for men and women separately. The optimal sensitivity and specificity obtained from the ROC curves for IR were 88 cm in women (sensitivity of 0.85, 95%CI (0.72-0.93), specificity of 0.58, 95%CI (0.49-0.66)) and 94 cm for men (sensitivity of 0.8, 95% CI (0.65-0.91), specificity of 0.61, 95% CI (0.51-0.71)). The data from the ROC curve for any two other MS criteria confirmed the results and the WC 88 cm in women (sensitivity of 0.82, 95% CI (0.72-0.9), specificity of 0.72, 95% CI (0.62-0.8)) and 94 cm in men (sensitivity of 0.74, 95% CI (0.62-0.84), specificity of 0.73, 95% CI (0.61-0.83)) were corresponded to the optimal sensitivity and specificity. WC ≥ 88 cm and ≥ 94 cm should be used as a criterion for the diagnosis of AO for Kyrgyz women and men respectively based on these results.
Röder, Martin; Vieths, Stefan; Holzhauser, Thomas
2009-09-01
Lateral flow devices (LFDs) are qualitative immunochromatographic tests for the rapid and specific detection of target analytes. We investigated commercially available LFDs for their ability to detect potentially allergenic peanut and hazelnut in raw cookie dough and chocolate, two important food matrices in the industrial production of cookies. Each three commercial LFDs for the detection of hazelnut and peanut were performed according to the manufacturers' instructions. All LFDs had comparably satisfactory specificity that was investigated with a variety of characteristic foods and food ingredients used in the production of cookies. In concordance with hazelnut-specific enzyme-linked immunosorbent assays (ELISAs), walnut was the most cross-reactive food for hazelnut-specific LFD. The sensitivity was verified in raw cookie doughs and chocolates that were either spiked with peanut or hazelnut between 1 and 25 mg/kg, respectively. Two hazelnut-specific LFDs detected hazelnut at a level of 3.5 mg/kg in both matrices, whereas the third LFD detected hazelnut at a level of 3.9 mg/kg in dough and 12.5 mg/kg in chocolate. Two peanut-specific LFDs detected peanut at a level of 1 mg/kg in both matrices. The third LFD detected peanut at a level of 14.2 mg/kg in chocolate and 4 mg/kg in dough. In conclusion, specific and sensitive LFD were identified for each hazelnut and peanut, having a level of sensitivity that is comparable to commercial ELISA for the investigated matrices. Such sensitive, specific, and rapid tests are useful analytical tools for allergen screening and sanitation in the industrial manufacture of foods.
Understanding Informal Learning in Small- and Medium-Sized Enterprises in South Korea
ERIC Educational Resources Information Center
Jeong, Shinhee; McLean, Gary N.; Park, Soyoun
2018-01-01
Purpose: This paper aims to explore informal learning experiences among employees working in South Korean small- and medium-sized enterprises (SMEs) with fewer than 100 employees. This study specifically seeks to understand the characteristics of informal learning in Korean SMEs and culturally sensitive contextual factors that shape informal…
Bredemeier, Keith; Spielberg, Jeffery M; Silton, Rebecca Levin; Berenbaum, Howard; Heller, Wendy; Miller, Gregory A
2010-09-01
The present study examined the utility of the anhedonic depression scale from the Mood and Anxiety Symptoms Questionnaire (MASQ-AD scale) as a way to screen for depressive disorders. Using receiver-operating characteristic analysis, we examined the sensitivity and specificity of the full 22-item MASQ-AD scale, as well as the 8- and 14-item subscales, in relation to both current and lifetime Diagnostic and Statistical Manual of Mental Disorders (4th ed.) depressive disorder diagnoses in two nonpatient samples. As a means of comparison, the sensitivity and specificity of a measure of a relevant personality dimension, Neuroticism, was also examined. Results from both samples support the clinical utility of the MASQ-AD scale as a means of screening for depressive disorders. Findings were strongest for the MASQ-AD 8-item subscale and when predicting current depression status. Furthermore, the MASQ-AD 8-item subscale outperformed the Neuroticism measure under certain conditions. The overall usefulness of the MASQ-AD scale as a screening device is discussed, as are possible cutoff scores for use in research.
Bredemeier, Keith; Spielberg, Jeffrey M.; Silton, Rebecca Levin; Berenbaum, Howard; Heller, Wendy; Miller, Gregory A.
2010-01-01
The present study examined the utility of the anhedonic depression scale from the Mood and Anxiety Symptoms Questionnaire (MASQ-AD) as a way to screen for depressive disorders. Using receiver-operator characteristic analysis, the sensitivity and specificity of the full 22-item MASQ-AD scale, as well as the 8 and 14-item subscales, were examined in relation to both current and lifetime DSM-IV depressive disorder diagnoses in two nonpatient samples. As a means of comparison, the sensitivity and specificity of a measure of a relevant personality dimension, neuroticism, was also examined. Results from both samples support the clinical utility of the MASQ-AD scale as a means of screening for depressive disorders. Findings were strongest for the MASQ-AD 8-item subscale and when predicting current depression status. Furthermore, the MASQ-AD 8-item subscale outperformed the neuroticism measure under certain conditions. The overall usefulness of the MASQ-AD scale as a screening device is discussed, as well as possible cutoff scores for use in research. PMID:20822283
Jiang, Wen Jun; Wittek, Peter; Zhao, Li; Gao, Shi Chao
2014-01-01
Photoplethysmogram (PPG) signals acquired by smartphone cameras are weaker than those acquired by dedicated pulse oximeters. Furthermore, the signals have lower sampling rates, have notches in the waveform and are more severely affected by baseline drift, leading to specific morphological characteristics. This paper introduces a new feature, the inverted triangular area, to address these specific characteristics. The new feature enables real-time adaptive waveform detection using an algorithm of linear time complexity. It can also recognize notches in the waveform and it is inherently robust to baseline drift. An implementation of the algorithm on Android is available for free download. We collected data from 24 volunteers and compared our algorithm in peak detection with two competing algorithms designed for PPG signals, Incremental-Merge Segmentation (IMS) and Adaptive Thresholding (ADT). A sensitivity of 98.0% and a positive predictive value of 98.8% were obtained, which were 7.7% higher than the IMS algorithm in sensitivity, and 8.3% higher than the ADT algorithm in positive predictive value. The experimental results confirmed the applicability of the proposed method.
Salo, Päivi M.; Arbes, Samuel J.; Jaramillo, Renee; Calatroni, Agustin; Weir, Charles H.; Sever, Michelle L.; Hoppin, Jane A.; Rose, Kathryn M.; Liu, Andrew H.; Gergen, Peter J.; Mitchell, Herman E.; Zeldin, Darryl C.
2014-01-01
Background Allergic sensitization is an important risk factor for the development of atopic disease. The National Health and Nutrition Examination Survey (NHANES) 2005–2006 provides the most comprehensive information on IgE-mediated sensitization in the general US population. Objective We investigated clustering, sociodemographic and regional patterns of allergic sensitization and examined risk factors associated with IgE-mediated sensitization. Methods Data for this cross-sectional analysis were obtained from NHANES 2005–2006. Participants aged ≥1 year (N=9440) were tested for sIgEs to inhalant and food allergens; participants ≥6 years were tested for 19 sIgEs, and children aged 1–5 years for 9 sIgEs. Serum samples were analyzed using the ImmunoCAP System. Information on demographics and participant characteristics was collected by questionnaire. Results Of the study population aged 6 and older, 44.6% had detectable sIgEs, while 36.2% of children aged 1–5 years were sensitized to ≥1 allergen. Allergen-specific IgEs clustered into 7 groups that might have largely reflected biological cross-reactivity. Although sensitization to individual allergens and allergen types showed regional variation, the overall prevalence of sensitization did not differ across census regions, except in early childhood. In multivariate modeling, young age, male gender, non-Hispanic black race/ethnicity, geographic location (census region), and reported pet avoidance measures were most consistently associated with IgE-mediated sensitization. Conclusions The overall prevalence of allergic sensitization does not vary across US census regions, except in early life, although allergen-specific sensitization differs by sociodemographic and regional factors. Biological cross-reactivity may be an important, but not a sole, contributor to the clustering of allergen-specific IgEs. Clinical implications IgE-mediated sensitization shows clustering patterns and differs by sociodemographic and regional factors, but the overall prevalence of sensitization may not vary across US census regions. PMID:24522093
Fazio, Rachel L; Sanders, James Forrest; Denney, Robert L
2015-06-01
Compared with the amount of neuropsychological literature surrounding response bias in civil litigation, there is little regarding criminal cases. This study adds to the criminal forensic neuropsychological literature by comparing the Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) in a criminal forensic setting utilizing a criterion-groups design. Subjects were classified into two groups based on their performance on at least two other freestanding performance validity tests. The WMT demonstrated good sensitivity (95.1%) but poor specificity (68.4%) when Genuine Memory Impaired Profiles (GMIPs) were not considered. Inclusion of GMIPs reduced the sensitivity to 56.1% but increased the specificity to 94.7%. The TOMM evidenced better sensitivity but poorer specificity than the WMT with GMIPs. Conjoint use of the tests was also considered. Receiver operating characteristics and other classification statistics for each measure are presented. Results support the use of these measures in a criminal forensic population. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
B-mode Ultrasound Versus Color Doppler Twinkling Artifact in Detecting Kidney Stones
Harper, Jonathan D.; Hsi, Ryan S.; Shah, Anup R.; Dighe, Manjiri K.; Carter, Stephen J.; Moshiri, Mariam; Paun, Marla; Lu, Wei; Bailey, Michael R.
2013-01-01
Abstract Purpose To compare color Doppler twinkling artifact and B-mode ultrasonography in detecting kidney stones. Patients and Methods Nine patients with recent CT scans prospectively underwent B-mode and twinkling artifact color Doppler ultrasonography on a commercial ultrasound machine. Video segments of the upper pole, interpolar area, and lower pole were created, randomized, and independently reviewed by three radiologists. Receiver operator characteristics were determined. Results There were 32 stones in 18 kidneys with a mean stone size of 8.9±7.5 mm. B-mode ultrasonography had 71% sensitivity, 48% specificity, 52% positive predictive value, and 68% negative predictive value, while twinkling artifact Doppler ultrasonography had 56% sensitivity, 74% specificity, 62% positive predictive value, and 68% negative predictive value. Conclusions When used alone, B-mode is more sensitive, but twinkling artifact is more specific in detecting kidney stones. This information may help users employ twinkling and B-mode to identify stones and developers to improve signal processing to harness the fundamental acoustic differences to ultimately improve stone detection. PMID:23067207
Fluorescence-based assay as a new screening tool for toxic chemicals
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-01-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients. PMID:27653274
Fluorescence-based assay as a new screening tool for toxic chemicals.
Moczko, Ewa; Mirkes, Evgeny M; Cáceres, César; Gorban, Alexander N; Piletsky, Sergey
2016-09-22
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Fluorescence-based assay as a new screening tool for toxic chemicals
NASA Astrophysics Data System (ADS)
Moczko, Ewa; Mirkes, Evgeny M.; Cáceres, César; Gorban, Alexander N.; Piletsky, Sergey
2016-09-01
Our study involves development of fluorescent cell-based diagnostic assay as a new approach in high-throughput screening method. This highly sensitive optical assay operates similarly to e-noses and e-tongues which combine semi-specific sensors and multivariate data analysis for monitoring biochemical processes. The optical assay consists of a mixture of environmental-sensitive fluorescent dyes and human skin cells that generate fluorescence spectra patterns distinctive for particular physico-chemical and physiological conditions. Using chemometric techniques the optical signal is processed providing qualitative information about analytical characteristics of the samples. This integrated approach has been successfully applied (with sensitivity of 93% and specificity of 97%) in assessing whether particular chemical agents are irritating or not for human skin. It has several advantages compared with traditional biochemical or biological assays and can impact the new way of high-throughput screening and understanding cell activity. It also can provide reliable and reproducible method for assessing a risk of exposing people to different harmful substances, identification active compounds in toxicity screening and safety assessment of drugs, cosmetic or their specific ingredients.
Evaluation of the Diagnostic Utility of the Traditional and Revised WHO Dengue Case Definitions
Gutiérrez, Gamaliel; Gresh, Lionel; Pérez, María Ángeles; Elizondo, Douglas; Avilés, William; Kuan, Guillermina; Balmaseda, Ángel; Harris, Eva
2013-01-01
Dengue, a mosquito-borne viral illness, is a major public health problem worldwide, and its incidence continues to increase. In 2009, the World Health Organization published guidelines that included a revision of the dengue case definition. Compared to the traditional definition, the revised case definition relies more on signs than on symptoms, making it more applicable to young children. We evaluated the diagnostic utility of both case definitions in two studies of pediatric dengue in Managua, Nicaragua. In a community-based cohort study, we included data from 3,407 suspected dengue cases, of which 476 were laboratory-confirmed. In the second study, we collected information from 1,160 participants recruited at the national pediatric reference hospital (723 laboratory-confirmed). In the cohort study, the traditional definition had 89.3% sensitivity and 43.1% specificity, while the revised definition yielded similar sensitivity (86.6%) and higher specificity (55.2%, p<0.001). In the hospital study, the traditional case definition yielded 96.7% sensitivity and 22.0% specificity, whereas the revised case definition had higher sensitivity (99.3%, p<0.001) but lower specificity (8.5%, p<0.001). We then evaluated the performance of two diagnostic models based on the signs/symptoms included in each definition by analyzing the effect of increasing numbers of signs/symptoms on the sensitivity and specificity of case capture. Receiver operating characteristic analysis showed a slightly better performance for the revised model in both studies. Interestingly, despite containing less symptoms that cannot be readily expressed by children aged less than 4 years, the revised definition did not perform better in this age group. Overall, our results indicate that both case definitions have similar capacity to diagnose dengue. Owing to their high sensitivity and low specificity, they should be primarily used for screening purposes. However, in a primary care setting, neither of the case definitions performed well as a screening test in younger children. PMID:23991237
Chua, Michael E; Gatchalian, Glenn T; Corsino, Michael Vincent; Reyes, Buenaventura B
2012-10-01
(1) To determine the best cut-off level of Hounsfield units (HU) in the CT stonogram that would predict the appearance of a urinary calculi in plain KUB X-ray; (2) to estimate the sensitivity and specificity of the best cut-off HU; and (3) to determine whether stone size and location affect the in vivo predictability. A prospective cross-sectional study of patients aged 18-85 diagnosed with urolithiases on CT stonogram with concurrent plain KUB radiograph was conducted. Appearance of stones was recorded, and significant difference between radiolucent and radio-opaque CT attenuation level was determined using ANOVA. Receiver operating characteristics (ROC) curve determined the best HU cut-off value. Stone size and location were used for factor variability analysis. A total of 184 cases were included in this study, and the average urolithiasis size on CT stonogram was 0.84 cm (0.3-4.9 cm). On KUB X-ray, 34.2 % of the urolithiases were radiolucent and 65.8 % were radio-opaque. Mean value of CT Hounsfield unit for radiolucent stones was 358.25 (±156), and that for radio-opaque stones was 816.51 (±274). ROC curve determined the best cut-off value of HU at 498.5, with the sensitivity of 89.3 % and specificity of 87.3 %. For >4 mm stones, the sensitivity was 91.3 % and the specificity was 81.8 %. On the other hand, for =<4 mm stones, the sensitivity was 60 % and the specificity was 89.5 %. Based on the constructed ROC curve, a threshold value of 498.5 HU in CT stonogram was established as cut-off in determining whether a calculus is radio-opaque or radiolucent. The determined overall sensitivity and specificity of the set cut-off HU value are optimal. Stone size but not location affects the sensitivity and specificity.
A highly sensitive and specific combined clinical and sonographic score to diagnose appendicitis.
Reddy, Swathi B; Kelleher, Michael; Bokhari, S A Jamal; Davis, Kimberly A; Schuster, Kevin M
2017-10-01
Computed tomography (CT) scanning reduces the negative appendectomy rate however it exposes the patient to ionizing radiation. Ultrasound (US) does not carry this risk but may be nondiagnostic. We hypothesized that a clinical-US scoring system would improve diagnostic accuracy. We conducted a retrospective review of all patients (age, >15 years) who presented through the emergency department with suspected appendicitis and underwent initial US. A US score was developed using odds ratios for appendicitis given appendiceal diameter, compressibility, hyperemia, free fluid, and focal or diffuse tenderness. The US score was then combined with the Alvarado score. Final diagnosis of appendicitis was assigned by pathology reports. Three hundred patients who underwent US as initial imaging were identified. Thirty-two patients with evident nonappendiceal pathology on US were excluded. In 114 (38%), the appendix was not visualized and partially visualized in 36 (12%). Fifty-seven (21.3%) had an appendectomy with 1 (1.7%) negative. Six nonvisualized appendicies underwent appendectomy, with no negative cases. Sensitivity and specificity for the sonographic score were 86% and 90%, respectively, at a score of 1.5. The combined score demonstrated 98% sensitivity and 82% specificity at 6.5, and 95% sensitivity, and 87% specificity at a score of 7.5. Sensitivity and specificity were confirmed by bootstrap resampling for validation. Area under receiver operating characteristic (ROC) curves for our new US score were similar to the ROC curve for the Alvarado score (91.9 and 91.1, p = 0.8). The combined US and Alvarado score yielded an area under the ROC curve of 97.1, significantly better than either score alone (p = 0.017 and p < 0.001, respectively). Our scoring system based entirely on US findings was highly sensitive and specific for appendicitis, and it significantly improved when combined with the Alvarado score. After prospective evaluation, the combined US-Alvarado score might replace the need for computed tomography imaging in a majority of patients. Diagnostic Test, Level III.
Toftaker, Ingrid; Toft, Nils; Stokstad, Maria; Sølverød, Liv; Harkiss, Gordon; Watt, Neil; O' Brien, Amanda; Nødtvedt, Ane
2018-06-01
Bovine respiratory syncytial virus (BRSV) and bovine coronavirus (BCV) are responsible for respiratory disease and diarrhea in cattle worldwide. The Norwegian control program against these infections is based on herd-level diagnosis using a new multiplex immunoassay. The objective of this study was to estimate sensitivity and specificity across different cut-off values for the MVD-Enferplex BCV/BRSV multiplex, by comparing them to a commercially available ELISA, the SVANOVIR ® BCV-Ab and SVANOVIR ® BRSV-Ab, respectively. We analyzed bulk tank milk samples from 360 herds in a low- and 360 herds in a high-prevalence area. As none of the tests were considered perfect, estimation of test characteristics was performed using Bayesian latent class models. At the manufacturers' recommended cut-off values, the median sensitivity for the BRSV multiplex and the BRSV ELISA was 94.4 [89.8-98.7 95% Posterior Credibility Interval (PCI)] and 99.8 [98.7-100 95% PCI], respectively. The median specificity for the BRSV multiplex was 90.6 [85.5-94.4 95% PCI], but only 57.4 [50.5-64.4 95% PCI] for the BRSV ELISA. However, increasing the cut-off of the BRSV ELISA increased specificity without compromising sensitivity. For the BCV multiplex we found that by using only one of the three antigens included in the test, the specificity increased, without concurrent loss in sensitivity. At the recommended cut-off this resulted in a sensitivity of 99.9 [99.3-100 95% PCI] and specificity of 93.7 [88.8-97.8 95% PCI] for the multiplex and a sensitivity of 99.5 [98.1-100 95% PCI] and a specificity of 99.6 [97.6-100 95% PCI] for the BCV ELISA. Copyright © 2018 Elsevier B.V. All rights reserved.
Atabek, Mehmet Emre; Pirgon, Ozgur
2007-02-01
Few previous studies have examined the validity of the fasting glucose-to-insulin ratio (FGIR), homeostasis model assessment of insulin resistance (HOMA-IR) and quantitative insulin-sensitivity check index (QUICKI) in pediatric populations. To compare simple indices of insulin resistance calculated from fasting glucose and insulin levels with insulin sensitivity indices (area under the response curve [AUCinsulin], insulin sensitivity index [ISI-compositeL) determined by oral glucose tolerance testing (OGTT) in obese children. One hundred and forty-eight obese children and adolescents (86 girls and 62 boys, mean age: 10.86 +/- 3.08 years, mean body mass index (BMI): 27.7 +/- 4.2) participated in the study. OGTT was performed in all participants. After glucose and insulin measurements from OGTT, the children were divided into two groups according to the presence or absence of insulin resistance. Insulin sensitivity indices obtained from the OGTT were compared between the groups. The total plasma glucose response and insulin secretion were evaluated from the AUC estimated by the trapezoid rule. Cut-off points, and sensitivity and specificity calculations were based on insulin resistance with receiver operating characteristic curve (ROC) analysis. The prevalence of insulin resistance, glucose intolerance and dyslipidemia was 37.1%, 24.3% and 54% in obese children, respectively. The groups consisted of 93 children without insulin resistance (54 girls and 39 boys; mean age: 10.5 +/- 3.3 years; mean BMI: 27.0 +/- 4.2) and 55 children with insulin resistance (32 girls and 23 boys; mean age: 11.4 +/- 2.5 years; mean BMI: 27.9 +/- 3.9). There were significant differences in mean FGIR (10.0 +/- 7.2 vs 5.6 +/- 2.8, p < 0.001), HOMA-IR (3.2 +/- 2.3 vs 4.9 +/- 2.3, p < 0.001) and QUICKI (0.33 +/- 0.03 vs 0.30 +/- 0.02, p < 0.001) between the groups. The cut-off points for diagnosis of insulin resistance were < 5.6 for FGIR (sensitivity 61.8, specificity 76.3), > 2.7 for HOMA-IR (sensitivity 80, specificity 59.1), and < 0.328 for QUICKI (sensitivity 80, specificity 60.2). Indices derived from fasting samples for diagnosis of insulin sensitivity are reliable criteria in obese children and adolescents. HOMA-IR and QUICKI appeared to have similar sensitivity and specificity and to have higher sensitivity than FGIR.
Cunningham, Daniel J; Kavolus, Joseph J; Bolognesi, Michael P; Wellman, Samuel S; Seyler, Thorsten M
2017-06-01
Periprosthetic hip infection treatment remains a significant challenge for orthopedics. Some studies have suggested that methicillin resistance and gram-negative organism type are associated with increased treatment failure. The aim of this research is to determine if specific organisms were associated with poor outcomes in treatment for hip periprosthetic infection. Records were reviewed of all patients between 2005 and 2015 who underwent treatment for infected partial or total hip arthroplasty. Characteristics of each patient's treatment course were determined including baseline characteristics, infecting organism(s), infection status at final follow-up, surgeries for infection, and time in hospital. Baseline characteristics and organisms that were associated with clinical outcomes in univariate analysis were incorporated into multivariable outcomes models. When compared with patients infected with other organism(s), patients infected with the following organisms had significantly decreased infection-free rates: Pseudomonas, methicillin-resistant Staphylococcus aureus (MRSA), and Proteus. Infection with certain organisms was associated with 1.13-2.58 additional surgeries: methicillin-sensitive S aureus, coagulase-negative Staphylococcus, MRSA, Pseudomonas, Peptostreptococcus, Klebsiella, Candida, diphtheroids, Propionibacterium acnes, and Proteus species. Specific organisms were associated with 8.56-24.54 additional days in hospital for infection: methicillin-sensitive S aureus, coagulase-negative Staphylococcus, Proteus, MRSA, Enterococcus, Pseudomonas, Klebsiella, beta-hemolytic Streptococcus, and diphtheroids. Higher comorbidity score was also associated with greater length of hospitalization. MRSA, Pseudomonas, and Proteus were associated with all 3 outcomes of lower infection-free rate, more surgery, and more time in hospital in treatment for hip periprosthetic infection. Organism-specific outcome information may help individualize patient-physician discussions about the expected course of treatment for hip periprosthetic infection. Copyright © 2017 Elsevier Inc. All rights reserved.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-12-01
To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.
Lu, Yanjun; Zhu, Yaowu; Shen, Na; Tian, Lei; Sun, Ziyong
2018-02-08
Limited data on the diagnostic accuracy of the Xpert MTB/RIF assay using bronchoalveolar lavage fluid from patients with suspected pulmonary tuberculosis (PTB) have been reported in China. Therefore, a retrospective study was designed to evaluate the diagnostic accuracy of this assay. Clinical, radiological, and microbiological characteristics of 238 patients with suspected PTB were reviewed retrospectively. The sensitivity, specificity, positive predictive value, and negative predictive value for the diagnosis of active PTB were calculated for the Xpert MTB/RIF assay using TB culture or final diagnosis based on clinical and radiological evaluation as the reference standard. The sensitivity and specificity of the Xpert MTB/RIF assay were 84.5% and 98.9%, respectively, and those for smear microscopy were 36.2% and 100%, respectively, when compared to the culture method. However, compared with the sensitivity and specificity of final diagnosis based on clinical and radiological evaluation, the sensitivity and specificity of the assay were 72.9% and 98.7%, respectively, which were significantly higher than those for smear microscopy. The Xpert MTB/RIF assay on bronchoalveolar lavage fluid could serve as an additional rapid diagnostic tool for PTB in a high TB-burden country and improve the time to TB treatment initiation in patients with PTB. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Higgins, Janet R; Lin, Feng-Chang; Evans, James P
2016-01-01
Plagiarism is common and threatens the integrity of the scientific literature. However, its detection is time consuming and difficult, presenting challenges to editors and publishers who are entrusted with ensuring the integrity of published literature. In this study, the extent of plagiarism in manuscripts submitted to a major specialty medical journal was documented. We manually curated submitted manuscripts and deemed an article contained plagiarism if one sentence had 80 % of the words copied from another published paper. Commercial plagiarism detection software was utilized and its use was optimized. In 400 consecutively submitted manuscripts, 17 % of submissions contained unacceptable levels of plagiarized material with 82 % of plagiarized manuscripts submitted from countries where English was not an official language. Using the most commonly employed commercial plagiarism detection software, sensitivity and specificity were studied with regard to the generated plagiarism score. The cutoff score maximizing both sensitivity and specificity was 15 % (sensitivity 84.8 % and specificity 80.5 %). Plagiarism was a common occurrence among manuscripts submitted for publication to a major American specialty medical journal and most manuscripts with plagiarized material were submitted from countries in which English was not an official language. The use of commercial plagiarism detection software can be optimized by selecting a cutoff score that reflects desired sensitivity and specificity.
Temperature sensitive surfaces and methods of making same
Liang, Liang [Richland, WA; Rieke, Peter C [Pasco, WA; Alford, Kentin L [Pasco, WA
2002-09-10
Poly-n-isopropylacrylamide surface coatings demonstrate the useful property of being able to switch charateristics depending upon temperature. More specifically, these coatings switch from being hydrophilic at low temperature to hydrophobic at high temperature. Research has been conducted for many years to better characterize and control the properties of temperature sensitive coatings. The present invention provides novel temperature sensitive coatings on articles and novel methods of making temperature sensitive coatings that are disposed on the surfaces of various articles. These novel coatings contain the reaction products of n-isopropylacrylamide and are characterized by their properties such as advancing contact angles. Numerous other characteristics such as coating thickness, surface roughness, and hydrophilic-to-hydrophobic transition temperatures are also described. The present invention includes articles having temperature-sensitve coatings with improved properties as well as improved methods for forming temperature sensitive coatings.
Utility of hepatic transaminases in children with concern for abuse.
Lindberg, Daniel M; Shapiro, Robert A; Blood, Emily A; Steiner, R Daryl; Berger, Rachel P
2013-02-01
Routine testing of hepatic transaminases, amylase, and lipase has been recommended for all children evaluated for physical abuse, but rates of screening are widely variable, even among abuse specialists, and data for amylase and lipase testing are lacking. A previous study of screening in centers that endorsed routine transaminase screening suggested that using a transaminase threshold of 80 IU/L could improve injury detection. Our objectives were to prospectively validate the test characteristics of the 80-IU/L threshold and to determine the utility of amylase and lipase to detect occult abdominal injury. This was a retrospective secondary analysis of the Examining Siblings To Recognize Abuse research network, a multicenter study in children younger than 10 years old who underwent subspecialty evaluation for physical abuse. We determined rates of identified abdominal injuries and results of transaminase, amylase, and lipase testing. Screening studies were compared by using basic test characteristics (sensitivity, specificity) and the area under the receiver operating characteristic curve. Abdominal injuries were identified in 82 of 2890 subjects (2.8%; 95% confidence interval: 2.3%-3.5%). Hepatic transaminases were obtained in 1538 (53%) subjects. Hepatic transaminases had an area under the receiver operating characteristic curve of 0.87. A threshold of 80 IU/L yielded sensitivity of 83.8% and specificity of 83.1%. The areas under the curve for amylase and lipase were 0.67 and 0.72, respectively. Children evaluated for physical abuse with transaminase levels >80 IU/L should undergo definitive testing for abdominal injury.
Li, Liang; Wang, Yiying; Xu, Jiting; Flora, Joseph R V; Hoque, Shamia; Berge, Nicole D
2018-08-01
Hydrothermal carbonization (HTC) is a wet, low temperature thermal conversion process that continues to gain attention for the generation of hydrochar. The importance of specific process conditions and feedstock properties on hydrochar characteristics is not well understood. To evaluate this, linear and non-linear models were developed to describe hydrochar characteristics based on data collected from HTC-related literature. A Sobol analysis was subsequently conducted to identify parameters that most influence hydrochar characteristics. Results from this analysis indicate that for each investigated hydrochar property, the model fit and predictive capability associated with the random forest models is superior to both the linear and regression tree models. Based on results from the Sobol analysis, the feedstock properties and process conditions most influential on hydrochar yield, carbon content, and energy content were identified. In addition, a variational process parameter sensitivity analysis was conducted to determine how feedstock property importance changes with process conditions. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fu, Fan; Sun, Shengjun; Liu, Liping; Li, Jianying; Su, Yaping; Li, Yingying
2018-04-19
The computed tomography angiography (CTA) spot sign is a validated predictor of haematoma expansion (HE) in spontaneous intracerebral haemorrhage (SICH). We investigated whether defining the iodine concentration (IC) inside the spot sign and the haematoma on Gemstone spectral imaging (GSI) would improve its sensitivity and specificity for predicting HE. From 2014 to 2016, we prospectively enrolled 65 SICH patients who underwent single-phase spectral CTA within 6 h. Logistic regression was performed to assess the risk factors for HE. The predictive performance of individual spot sign characteristics was examined via receiver operating characteristic (ROC) analysis. The spot sign was detected in 46.1% (30/65) of patients. ROC analysis indicated that IC inside the spot sign had the greatest area under the ROC curve for HE (0.858; 95% confidence interval, 0.727-0.989; p = 0.003). Multivariate analysis found that spot sign with higher IC (i.e. IC > 7.82 100 μg/ml) was an independent predictor of HE (odds ratio = 34.27; 95% confidence interval, 5.608-209.41; p < 0.001) with sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 0.81, 0.75, 0.90 and 0.60, respectively; while the spot sign showed sensitivity, specificity, PPV and NPV of 0.81, 0.79, 0.73 and 0.86. Logistic regression analysis indicated that the IC in haematomas was independently associated with HE (odds ratio = 1.525; 95% confidence interval, 1.041-2.235; p = 0.030). ICs in haematoma and in spot sign were all independently associated with HE. IC analysis in spectral imaging may help to identify SICH patients for targeted haemostatic therapy. • Iodine concentration in spot sign and haematoma can predict haematoma expansion • Spectral imaging could measure the IC inside the spot sign and haematoma • IC in spot sign improved the positive predictive value (PPV) cf. CTA.
Koizumi, Mitsuru; Motegi, Kazuki; Koyama, Masamichi; Terauchi, Takashi; Yuasa, Takeshi; Yonese, Junji
2017-08-01
The computer-assisted diagnostic system for bone scintigraphy (BS) BONENAVI is used to evaluate skeletal metastasis. We investigated its diagnostic performance in prostate cancer patients with and without skeletal metastasis and searched for the problems. An artificial neural network (ANN) value was calculated in 226 prostate cancer patients (124 with skeletal metastasis and 101 without) using BS. Receiver operating characteristic curve analysis was performed and the sensitivity and specificity determined (cutoff ANN = 0.5). Patient's situation at the time of diagnosis of skeletal metastasis, computed tomography (CT) type, extent of disease (EOD), and BS uptake grade were analyzed. False-negative and false-positive results were recorded. BONENAVI showed 82% (102/124) of sensitivity and 83% (84/101) specificity for metastasis detection. There were no significant differences among CT types, although low EOD and faint BS uptake were associated with low ANN values and low sensitivity. Patients showed lower sensitivity during the follow-up period than staging work-up. False-negative lesions were often located in the pelvis or adjacent to it. They comprised not only solitary, faint BS lesions but also overlaying to urinary excretion. BONENAVI with BS has good sensitivity and specificity for detecting prostate cancer's osseous metastasis. Low EOD and faint BS uptake are associated with low sensitivity but not the CT type. Prostate cancer patients likely to have false-negative results during the follow-up period had a solitary lesion in the pelvis with faint BS uptake or lesions overlaying to urinary excretion.
Quantitative assessment of serum-specific IgE in the diagnosis of human cystic echinococcosis.
Marinova, I; Nikolov, G; Michova, A; Kurdova, R; Petrunov, B
2011-07-01
Anti-Echinococcus serum immunoglobulin (Ig)E was assessed by the ImmunoCAP system and compared with anti-Echinococcus serum IgG assessed by enzyme-linked immunosorbent assay (ELISA) and Western blot. The ImmunoCAP system revealed very high specificity (one false positive of 110 healthy individuals), low cross-reactivity (one false positive of 58 patients with other diseases) and decreased sensitivity (73.55%). Receiver operating characteristic analysis displayed a beneficial diagnostic value with high accuracy. Comparison of the ImmunoCAP system with ELISA and Western blot showed significantly higher specificity and significantly lower cross-reactivity compared with the ELISA. Examination of sera from 155 patients with cystic echinococcosis (CE) showed varying levels of anti-Echinococcus IgE (range, 0.01-118.33 kUA/L). However, most samples had moderately elevated IgE levels. Analysis of serum-specific IgE revealed significantly higher sensitivity of the ImmunoCAP system and significantly higher antibody levels in hepatic CE compared with pulmonary CE. © 2011 Blackwell Publishing Ltd.
Antonios, Tarek F T; Nama, Vivek; Wang, Duolao; Manyonda, Isaac T
2013-09-01
Preeclampsia is a major cause of maternal and neonatal mortality and morbidity. The incidence of preeclampsia seems to be rising because of increased prevalence of predisposing disorders, such as essential hypertension, diabetes, and obesity, and there is increasing evidence to suggest widespread microcirculatory abnormalities before the onset of preeclampsia. We hypothesized that quantifying capillary rarefaction could be helpful in the clinical prediction of preeclampsia. We measured skin capillary density according to a well-validated protocol at 5 consecutive predetermined visits in 322 consecutive white women, of whom 16 subjects developed preeclampsia. We found that structural capillary rarefaction at 20-24 weeks of gestation yielded a sensitivity of 0.87 with a specificity of 0.50 at the cutoff of 2 capillaries/field with the area under the curve of the receiver operating characteristic value of 0.70, whereas capillary rarefaction at 27-32 weeks of gestation yielded a sensitivity of 0.75 and a higher specificity of 0.77 at the cutoff of 8 capillaries/field with area under the curve of the receiver operating characteristic value of 0.82. Combining capillary rarefaction with uterine artery Doppler pulsatility index increased the sensitivity and specificity of the prediction. Multivariable analysis shows that the odds of preeclampsia are increased in women with previous history of preeclampsia or chronic hypertension and in those with increased uterine artery Doppler pulsatility index, but the most powerful and independent predictor of preeclampsia was capillary rarefaction at 27-32 weeks. Quantifying structural rarefaction of skin capillaries in pregnancy is a potentially useful clinical marker for the prediction of preeclampsia.
Prevalence of problem drinking and characteristics of a single-question screen.
Stewart, Scott H; Borg, Keith T; Miller, Peter M
2010-09-01
Hazardous drinking and alcohol use disorders (i.e, abuse and dependence) are common in Emergency Departments (EDs). This study examined 1) the prevalence of these conditions among ED patients and 2) characteristics of a single screening question (having consumed at least five drinks for males or four for females during a single day). Data from the National Epidemiologic Survey on Alcohol and Related Conditions were analyzed. Logistic regression for clustered data was used to estimate the relative risk for past-year ED use associated with hazardous drinking, abuse, and dependence. Contingency tables were analyzed to estimate the sensitivity and specificity of the single-question screen for detecting these conditions. Hazardous drinking was not associated with ED utilization. Alcohol abuse was associated with a relative risk of 1.3 (95% confidence interval [CI] 1.1-1.5) and alcohol dependence with a relative risk of 1.9 (95% CI 1.6-2.2). For current drinkers, the single question screen was 0.96, 0.85, and 0.90 sensitive for hazardous drinking, alcohol abuse, and alcohol dependence, respectively. Individuals with a positive screen in the past year were considered at least hazardous drinkers, and specificity was 0.80, 0.64, and 0.65 for hazardous drinking, abuse, and dependence, respectively. Specificity was modestly increased in women. Most problem drinkers were hazardous drinkers, but only severe alcohol use disorders were particularly prevalent in the ED. The single heavy-drinking-day item appears sensitive for problem drinking. Positive tests must be followed by additional assessment to differentiate hazardous drinking from alcohol use disorders. Copyright © 2010. Published by Elsevier Inc.
Piña Borrego, Carlos Enrique; Fernández Fernández, María de Lourdes; Fonte Rodríguez, Norge; Piña Rodríguez, Lorena Karla
Obesity is one of the principal non declarable diseases affecting children and adolescents. With the objective of developing a predictive instrument to identify high-risk adolescents with obesity, a cohort prospective study was carried out at the Policlinic "Manuel González Díaz", Bahía Honda City from 2013-2014. It was developed in three stages. In the first stage, 1800 adolescents from 10-19 years of age were included. The prevalence was identified and the most relevant characteristics of obesity were described (defined as body mass index >97 th percentile according to age and sex). In the second stage we identified the possibility of the diagnosis of factors that increase the probability of obesity. The third stage elaborated and validated an obesity predictor instrument from the results of the initial stages. To apply the instrument to sample A for internal elaboration and validation, sensitivity was 77.78% and specificity was 86.11%. Area under the curve (AUC) receiver operating characteristic (ROC) was 0.86, whereas for sample B the sensitivity was 79.63% and specificity was 92.13%. Positive predictive value (PPV) was 83.5% and negative predictive value (NPV) was 90.05%. The instrument allows predicting the risk for developing obesity in adolescents with acceptable sensitivity and high specificity. Its routine application will be interesting in pediatric health consultations. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Validation of the Hospital Anxiety and Depression Scale in patients with epilepsy.
Wiglusz, Mariusz S; Landowski, Jerzy; Michalak, Lidia; Cubała, Wiesław J
2016-05-01
Despite the fact that depressive disorders are the most common comorbidities among patients with epilepsy (PWEs), they often go unrecognized and untreated. The availability of validated screening instruments to detect depression in PWEs is limited. The aim of the present study was to validate the Hospital Anxiety and Depression Scale (HADS) in adult PWEs. A consecutive group of 118 outpatient PWEs was invited to participate in the study. Ninety-six patients met inclusion criteria, completed HADS, and were examined by a trained psychiatrist using Structured Clinical Interview (SCID-I) for DSM-IV-TR. Receiver operating characteristic (ROC) curves were used to determine the optimal threshold scores for the HADS depression subscale (HADS-D). Receiver operating characteristic analyses showed areas under the curve at approximately 84%. For diagnoses of MDD, the HADS-D demonstrated the best psychometric properties for a cutoff score ≥7 with sensitivity of 90.5%, specificity of 70.7%, positive predictive value of 46.3%, and negative predictive value of 96.4%. In the case of the group with 'any depressive disorder', the HADS-D optimum cutoff score was ≥6 with sensitivity of 82.5%, specificity of 73.2%, positive predictive value of 68.8%, and negative predictive value of 85.4%. The HADS-D proved to be a valid and reliable psychometric instrument in terms of screening for depressive disorders in PWEs. In the epilepsy setting, HADS-D maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing MDD with an optimum cutoff score ≥7. Copyright © 2016 Elsevier Inc. All rights reserved.
The utility of the Edmonton Symptom Assessment System in screening for anxiety and depression.
Bagha, S M; Macedo, A; Jacks, L M; Lo, C; Zimmermann, C; Rodin, G; Li, M
2013-01-01
The Edmonton Symptom Assessment System (ESAS) is a common screening tool in cancer, although its validity for distress screening is unproven. Here, screening performance of the ESAS anxiety (ESAS-A) and depression (ESAS-D) items were validated against the anxiety [Generalised Anxiety Disorder-7 (GAD-7)] and depression [Patient Health Questionnaire-9 (PHQ-9)] subscales of the PHQ. A total of 1215 cancer patients completed the Distress Assessment and Response Tool (DART), a computerised distress screening instrument. Spearman's rank correlation coefficients and receiver operating characteristic curve analyses were used to evaluate the ability of ESAS-A and ESAS-D to identify moderate distress (GAD-7/PHQ-9 ≥ 10). Spearman's rank correlation coefficients comparing ESAS-A and ESAS-D with GAD-7 and PHQ-9 were 0.74 and 0.72 respectively. Areas under the receiver operating characteristic curves were 0.89 and 0.88 for anxiety and depression respectively. A cut-off of ≥3 on ESAS-A demonstrated a sensitivity of 0.91, specificity of 0.68, positive predictive value of 0.34 and negative predictive value of 0.97. A cut-off of ≥2 on the ESAS-D demonstrated a sensitivity of 0.86, specificity of 0.72, positive predictive value of 0.46 and negative predictive value of 0.95. High sensitivities of ESAS-A and ESAS-D at certain cut-offs suggest they have use in ruling-out distress. However, their low specificities indicate secondary screening is needed to rule-in anxiety or depression for case-finding. © 2012 Blackwell Publishing Ltd.
He, Hongying; Plaxco, Jeri S; Wei, Wei; Huo, Lei; Candelaria, Rosalind P; Kuerer, Henry M; Yang, Wei T
2016-09-01
To compare the incremental cancer detection rate (ICDR) using bilateral whole-breast ultrasonography (BWBUS) vs dynamic contrast-enhanced MRI in patients with primary breast cancer. A retrospective database search in a single institution identified 259 patients with breast cancer diagnosed from January 2011 to August 2014 who underwent mammography, BWBUS and MRI before surgery. Patient characteristics, tumour characteristics and lesions seen on each imaging modality were recorded. The sensitivity, specificity and accuracy for each modality were calculated. ICDRs according to index tumour histology and receptor status were also evaluated. The effect of additional cancer detection on surgical planning was obtained from the medical records. A total of 266 additional lesions beyond 273 index malignancies were seen on at least 1 modality, of which 121 (45%) lesions were malignant and 145 (55%) lesions were benign. MRI was significantly more sensitive than BWBUS (p = 0.01), while BWBUS was significantly more accurate and specific than MRI (p < 0.0001). Compared with mammography, the ICDRs using BWBUS and MRI were significantly higher for oestrogen receptor-positive and triple-negative cancers, but not for human epidermal growth factor receptor 2-positive cancers. 22 additional malignant lesions in 18 patients were seen on MRI only. Surgical planning remained unchanged in 8 (44%) of those 18 patients. MRI was more sensitive than BWBUS, while BWBUS was more accurate and specific than MRI. MRI-detected additional malignant lesions did not change surgical planning in almost half of these patients. BWBUS may be a cost-effective and practical tool in breast cancer staging.
Li, Bin; Chen, Fei; Liu, Yi; Xu, Guokang
Total joint arthroplasty (TJA) has been one of the most beneficial interventions for treating patients suffering from joint disorders. However, peri-prosthetic joint infection (PJI) is a serious complication that often accompanies TJA and the diagnosis of PJI is remains difficult. Questions remain regarding whether certain biomarkers can be valuable in the diagnosis of PJI. We conducted our systematic review by searching PubMed, Embase, Web of Science, the Cochrane Library, and Science Direct with the key words "periprosthetic joint infection," "synovial fluid," and "α-defensin." Studies that provided sufficient data to construct 2 × 2 contingency tables were chosen based on inclusion and exclusion criteria. The quality of included studies was assessed according to the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) were calculated for the included studies. The summary receiver operating characteristic (SROC) curve and the area under the summary receiver operating characteristic (AUSROC) were used to evaluate the overall diagnostic performance. Eight studies were included in this systematic review. Among them four articles were included in meta-analysis. A total of 421 participants were studied in the meta-analysis. The pooled sensitivity, specificity, and DOR were 0.98 (95% confidence interval [CI]: 0.94-1.00), 0.97 (95% CI: 0.95-0.99), and 1095.49 (95% CI: 283.68.58-4230.45), respectively. The AUSROC was 0.9949 (standard error [SE] 0.0095). Synovial fluid α-defensin is a biomarker of high sensitivity and specificity for the diagnosis of PJI.
2017-01-01
Objective To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Methods Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. Results VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. Conclusion We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia. PMID:29201816
Park, Chul-Hyun; Kim, Don-Kyu; Lee, Yong-Taek; Yi, Youbin; Lee, Jung-Sang; Kim, Kunwoo; Park, Jung Ho; Yoon, Kyung Jae
2017-10-01
To compare swallowing function between healthy subjects and patients with pharyngeal dysphagia using high resolution manometry (HRM) and to evaluate the usefulness of HRM for detecting pharyngeal dysphagia. Seventy-five patients with dysphagia and 28 healthy subjects were included in this study. Diagnosis of dysphagia was confirmed by a videofluoroscopy. HRM was performed to measure pressure and timing information at the velopharynx (VP), tongue base (TB), and upper esophageal sphincter (UES). HRM parameters were compared between dysphagia and healthy groups. Optimal threshold values of significant HRM parameters for dysphagia were determined. VP maximal pressure, TB maximal pressure, UES relaxation duration, and UES resting pressure were lower in the dysphagia group than those in healthy group. UES minimal pressure was higher in dysphagia group than in the healthy group. Receiver operating characteristic (ROC) analyses were conducted to validate optimal threshold values for significant HRM parameters to identify patients with pharyngeal dysphagia. With maximal VP pressure at a threshold value of 144.0 mmHg, dysphagia was identified with 96.4% sensitivity and 74.7% specificity. With maximal TB pressure at a threshold value of 158.0 mmHg, dysphagia was identified with 96.4% sensitivity and 77.3% specificity. At a threshold value of 2.0 mmHg for UES minimal pressure, dysphagia was diagnosed at 74.7% sensitivity and 60.7% specificity. Lastly, UES relaxation duration of <0.58 seconds had 85.7% sensitivity and 65.3% specificity, and UES resting pressure of <75.0 mmHg had 89.3% sensitivity and 90.7% specificity for identifying dysphagia. We present evidence that HRM could be a useful evaluation tool for detecting pharyngeal dysphagia.
Hwang, Harry S; Orloff, Lisa A
2011-03-01
This study was performed to assess the diagnostic accuracy of surgeon-performed preoperative neck ultrasound (US) in the detection of both central and lateral cervical lymph node metastases from thyroid cancer. Prospective cohort study. Data for all patients with thyroid cancers and follicular thyroid lesions who were evaluated by means of preoperative neck US were reviewed. The cervical lymph nodes were assessed for suspicion of metastasis based on US characteristics. The diagnostic accuracy of US was determined according to whether histologically confirmed cancer was present in surgical cervical lymph node specimens. The sensitivity and specificity of US in predicting papillary thyroid carcinoma (PTC) metastasis in the central neck were 30.0% and 86.8%, respectively. The sensitivity and specificity of US in predicting metastasis in the lateral neck were 93.8% and 80.0%, respectively. A subset of patients underwent US followed by revision neck dissection for PTC, and the sensitivity and specificity of US in predicting metastasis in the lateral neck were 100% and 100%, respectively. Preoperative neck US is a valuable tool in assessing patients with thyroid cancers. The highly sensitive and specific nature of US in predicting cervical lymph node metastasis in the lateral neck, especially in the setting of recurrent disease, can provide reliable information to assist in surgical management. Although US for central compartment lymphadenopathy in the presence of the thyroid gland is less sensitive and specific than US for the lateral neck, it still provides useful information that can be obtained at the same time the primary thyroid pathology is assessed. Copyright © 2010 The American Laryngological, Rhinological, and Otological Society, Inc.
Is it possible to shorten ambulatory blood pressure monitoring?
Wolak, Talya; Wilk, Lior; Paran, Esther; Wolak, Arik; Gutmacher, Bella; Shleyfer, Elena; Friger, Michael
2013-08-01
The aim of this investigation was to find a time segment in which average blood pressure (BP) has the best correlation with 24-hour BP control. A total of 240 patients with full ambulatory BP monitoring (ABPM) were included; 120 had controlled BP (systolic BP [SBP] ≤135 mm Hg and diastolic BP [DBP] ≤85 mm Hg) and 120 had uncontrolled BP (SBP >135 mm Hg and/or DBP >85 mm Hg). Each ABPM was divided into 6- and 8-hour segments. Evaluation for correlation between mean BP for each time segment and 24-hour BP control was performed using receiver operating characteristic curve analysis and Youden's index for threshold with the best sensitivity and specificity. The mean BP in the following segments showed the highest area under the curve (AUC) compared with average controlled 24-hour BP: SBP 2 am to 8 am (AUC, 0.918; threshold value of 133.5 mm Hg, sensitivity-0.752 and specificity-0.904); SBP 2 pm to 10 pm (AUC, 0.911; threshold value of 138.5 mm Hg, sensitivity-0.803 and specificity-0.878); and SBP 6 am to 2 pm (AUC, 0.903; threshold value of 140.5 mm Hg, sensitivity-0.778 and specificity-0.888). The time segment 2 pm to 10 pm was shown to have good correlation with 24-hour BP control (AUC >0.9; sensitivity and specificity >80%). This time segment might replace full ABPM as a screening measure for BP control or as abbreviated ABPM for patients with difficulty in performing full ABPM. © 2013 Wiley Periodicals, Inc.
Diagnostic value of serum Golgi protein 73 for HBV-related primary hepatic carcinoma
Gao, Guosheng; Dong, Feibo; Xu, Xiaozhen; Hu, Airong; Hu, Yaoren
2015-01-01
Background: Alpha-fetoprotein (AFP) levels are routinely used for diagnosis and monitoring of hepatic diseases, but it has a limited value. Golgi protein 73 (GP73) has been suggested as a new marker for hepatic diseases. Objective: To explore the clinical value of serum GP73 in different diseases associated with hepatitis B virus (HBV) infection. Method: Between January 2010 and August 2014, serum samples from 88 patients with chronic hepatitis B (CHB), 78 patients with HBV-related liver cirrhosis (LC), and 194 patients with HBV-related primary hepatic cancer (PHC) were collected. Serum samples from 30 healthy volunteers were used as controls. ELISA and microparticle enzyme immunoassay were used to measure serum GP73 and AFP levels. Receiver operating characteristic (ROC) curves were used to analyze the diagnostic value of serum GP73 and AFP for PHC. Results: For the diagnosis of PHC, GP73 showed a sensitivity of 65.5% and specificity of 66.3%, while AFP levels showed sensitivity of 64.4% and specificity of 76.5%. Serial testing (both tests are positive) could increase the specificity (sensitivity of 45.9% and specificity of 85.5%) while parallel testing (any single positive test result) could increase the sensitivity (sensitivity of 84.0% and specificity of 57.2%). Serum GP73 and AFP levels were significantly different between Child-Pugh grades (P<0.001 for GP73 and P=0.044 for AFP). Significant differences in serum GP73 and AFP were found between TNM stages (all P<0.001). Conclusion: Serum GP73 had limited diagnostic value for HBV-related PHC. The combined use of serum GP73 and AFP levels improved the diagnostic efficacy. PMID:26617863
Barriga, E. Simon; Murray, Victor; Nemeth, Sheila; Crammer, Robert; Bauman, Wendall; Zamora, Gilberto; Pattichis, Marios S.; Soliz, Peter
2011-01-01
Purpose. To describe and evaluate the performance of an algorithm that automatically classifies images with pathologic features commonly found in diabetic retinopathy (DR) and age-related macular degeneration (AMD). Methods. Retinal digital photographs (N = 2247) of three fields of view (FOV) were obtained of the eyes of 822 patients at two centers: The Retina Institute of South Texas (RIST, San Antonio, TX) and The University of Texas Health Science Center San Antonio (UTHSCSA). Ground truth was provided for the presence of pathologic conditions, including microaneurysms, hemorrhages, exudates, neovascularization in the optic disc and elsewhere, drusen, abnormal pigmentation, and geographic atrophy. The algorithm was used to report on the presence or absence of disease. A detection threshold was applied to obtain different values of sensitivity and specificity with respect to ground truth and to construct a receiver operating characteristic (ROC) curve. Results. The system achieved an average area under the ROC curve (AUC) of 0.89 for detection of DR and of 0.92 for detection of sight-threatening DR (STDR). With a fixed specificity of 0.50, the system's sensitivity ranged from 0.92 for all DR cases to 1.00 for clinically significant macular edema (CSME). Conclusions. A computer-aided algorithm was trained to detect different types of pathologic retinal conditions. The cases of hard exudates within 1 disc diameter (DD) of the fovea (surrogate for CSME) were detected with very high accuracy (sensitivity = 1, specificity = 0.50), whereas mild nonproliferative DR was the most challenging condition (sensitivity= 0.92, specificity = 0.50). The algorithm was also tested on images with signs of AMD, achieving a performance of AUC of 0.84 (sensitivity = 0.94, specificity = 0.50). PMID:21666234
Agurto, Carla; Barriga, E Simon; Murray, Victor; Nemeth, Sheila; Crammer, Robert; Bauman, Wendall; Zamora, Gilberto; Pattichis, Marios S; Soliz, Peter
2011-07-29
To describe and evaluate the performance of an algorithm that automatically classifies images with pathologic features commonly found in diabetic retinopathy (DR) and age-related macular degeneration (AMD). Retinal digital photographs (N = 2247) of three fields of view (FOV) were obtained of the eyes of 822 patients at two centers: The Retina Institute of South Texas (RIST, San Antonio, TX) and The University of Texas Health Science Center San Antonio (UTHSCSA). Ground truth was provided for the presence of pathologic conditions, including microaneurysms, hemorrhages, exudates, neovascularization in the optic disc and elsewhere, drusen, abnormal pigmentation, and geographic atrophy. The algorithm was used to report on the presence or absence of disease. A detection threshold was applied to obtain different values of sensitivity and specificity with respect to ground truth and to construct a receiver operating characteristic (ROC) curve. The system achieved an average area under the ROC curve (AUC) of 0.89 for detection of DR and of 0.92 for detection of sight-threatening DR (STDR). With a fixed specificity of 0.50, the system's sensitivity ranged from 0.92 for all DR cases to 1.00 for clinically significant macular edema (CSME). A computer-aided algorithm was trained to detect different types of pathologic retinal conditions. The cases of hard exudates within 1 disc diameter (DD) of the fovea (surrogate for CSME) were detected with very high accuracy (sensitivity = 1, specificity = 0.50), whereas mild nonproliferative DR was the most challenging condition (sensitivity = 0.92, specificity = 0.50). The algorithm was also tested on images with signs of AMD, achieving a performance of AUC of 0.84 (sensitivity = 0.94, specificity = 0.50).
Kiss, Joseph E.; Steele, Whitney R.; Wright, David J.; Mast, Alan E.; Carey, Patricia M.; Murphy, Edward L.; Gottschall, Jerry L.; Simon, Toby L.; Cable, Ritchard G.
2014-01-01
BACKGROUND Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. STUDY DESIGN AND METHODS A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/ RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 µ.g/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. RESULTS HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 u.g/L was a good surrogate for assessing IDE. CONCLUSION RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. PMID:23617531
Development and validation of a registry-based definition of eosinophilic esophagitis in Denmark
Dellon, Evan S; Erichsen, Rune; Pedersen, Lars; Shaheen, Nicholas J; Baron, John A; Sørensen, Henrik T; Vyberg, Mogens
2013-01-01
AIM: To develop and validate a case definition of eosinophilic esophagitis (EoE) in the linked Danish health registries. METHODS: For case definition development, we queried the Danish medical registries from 2006-2007 to identify candidate cases of EoE in Northern Denmark. All International Classification of Diseases-10 (ICD-10) and prescription codes were obtained, and archived pathology slides were obtained and re-reviewed to determine case status. We used an iterative process to select inclusion/exclusion codes, refine the case definition, and optimize sensitivity and specificity. We then re-queried the registries from 2008-2009 to yield a validation set. The case definition algorithm was applied, and sensitivity and specificity were calculated. RESULTS: Of the 51 and 49 candidate cases identified in both the development and validation sets, 21 and 24 had EoE, respectively. Characteristics of EoE cases in the development set [mean age 35 years; 76% male; 86% dysphagia; 103 eosinophils per high-power field (eos/hpf)] were similar to those in the validation set (mean age 42 years; 83% male; 67% dysphagia; 77 eos/hpf). Re-review of archived slides confirmed that the pathology coding for esophageal eosinophilia was correct in greater than 90% of cases. Two registry-based case algorithms based on pathology, ICD-10, and pharmacy codes were successfully generated in the development set, one that was sensitive (90%) and one that was specific (97%). When these algorithms were applied to the validation set, they remained sensitive (88%) and specific (96%). CONCLUSION: Two registry-based definitions, one highly sensitive and one highly specific, were developed and validated for the linked Danish national health databases, making future population-based studies feasible. PMID:23382628
The utility of serum tryptase in the diagnosis of food-induced anaphylaxis.
Wongkaewpothong, Patcharaporn; Pacharn, Punchama; Sripramong, Chaweewan; Boonchoo, Siribangon; Piboonpocanun, Surapon; Visitsunthorn, Nualanong; Vichyanond, Pakit; Jirapongsananuruk, Orathai
2014-07-01
This study investigates the utility of serum tryptase for the confirmation of shrimp-induced anaphylaxis. Patients with a history of shrimp allergy and positive skin prick tests (SPT) to commercial shrimp extract were recruited for shrimp challenges. Serum total tryptase was obtained at baseline and 60 min (peak) after the onset of symptoms. Thirty-nine patients were challenged. There were 12 patients with anaphylaxis, 20 with mild reactions and 7 without symptoms (control group). Characteristic features and baseline tryptase were not different among the 3 groups. The peak tryptase levels were higher than the baseline in anaphylaxis and mild reaction groups (P<0.05). The delta-tryptase (peak minus baseline) and the tryptase ratio (peak divided by baseline) in the anaphylaxis group were higher than the mild reaction and control groups (P<0.01). The optimum cut-off for peak tryptase to confirm anaphylaxis was 2.99 µg/L with 50% sensitivity, 85% specificity, 3.33 positive likelihood ratio (LR) and 0.59 negative LR. The manufacturer's cut-off for peak tryptase was >11.4 µg/L with 17% sensitivity, 100% specificity, infinity positive LR and 0.83 negative LR. The best cut-off for delta-tryptase was ≥0.8 µg/L with 83% sensitivity, 93% specificity, 11.86 positive LR and 0.18 negative LR. The best cut-off for tryptase ratio was ≥1.5 with 92% sensitivity, 96% specificity, 23 positive LR and 0.08 negative LR. The peak tryptase level should be compared with the baseline value to confirm anaphylaxis. The tryptase ratio provide the best sensitivity, specificity, positive and negative LR than a single peak serum tryptase for the confirmation of shrimp-induced anaphylaxis.
Kiss, Joseph E; Steele, Whitney R; Wright, David J; Mast, Alan E; Carey, Patricia M; Murphy, Edward L; Gottschall, Jerry L; Simon, Toby L; Cable, Ritchard G
2013-11-01
Iron deficiency is common in regular blood donors. We evaluated the diagnostic sensitivity and specificity of red blood cell (RBC) hematology analyzer indices to assess iron status as a part of donor management. A total of 1659 male and female donors from the Retrovirus Epidemiology Donor Study-II (REDS-II) Donor Iron Status Evaluation (RISE) study who were either first-time/reactivated (FT/RA; no donations for 2 years) or frequent donors were recruited into a longitudinal study of regular donation of RBCs. Of these, 1002 donors returned 15 to 24 months later for a final assessment. Absent iron stores (AIS) was defined as plasma ferritin level of less than 12 μg/L. Logarithm of the ratio of soluble transferrin receptor to ferritin of at least 2.07 (≥97.5% in FT/RA males) was used to define iron-deficient erythropoiesis (IDE). Receiver operating characteristics analysis was performed to assess selected RBC indices (e.g., percentage of hypochromic mature RBCs, proportion of hypochromic mature RBCs [HYPOm], and hemoglobin [Hb] content of reticulocytes [CHr]) in identifying AIS and IDE. HYPOm and CHr detected IDE with comparable sensitivity, 72% versus 69%, but differed in specificity: HYPOm 68% and CHr 53%. For detecting AIS, sensitivity was improved to 85% for HYPOm and 81% for CHr but specificity was reduced for both. Venous Hb had high specificity but poor sensitivity for IDE and AIS. A plasma ferritin level of less than 26.7 μg/L was a good surrogate for assessing IDE. RBC indices correlate with AIS and IDE and are more informative than Hb measurement, but lack sufficient sensitivity and specificity to be used as diagnostic tools in blood donors at risk for iron deficiency. © 2013 American Association of Blood Banks.
Olsen, Anders Vinther; Stephansen, Jens; Leary, Eileen; Peppard, Paul E; Sheungshul, Hong; Jennum, Poul Jørgen; Sorensen, Helge; Mignot, Emmanuel
2017-04-15
Type 1 narcolepsy (NT1) is characterized by symptoms believed to represent Rapid Eye Movement (REM) sleep stage dissociations, occurrences where features of wake and REM sleep are intermingled, resulting in a mixed state. We hypothesized that sleep stage dissociations can be objectively detected through the analysis of nocturnal Polysomnography (PSG) data, and that those affecting REM sleep can be used as a diagnostic feature for narcolepsy. A Linear Discriminant Analysis (LDA) model using 38 features extracted from EOG, EMG and EEG was used in control subjects to select features differentiating wake, stage N1, N2, N3 and REM sleep. Sleep stage differentiation was next represented in a 2D projection. Features characteristic of sleep stage differences were estimated from the residual sleep stage probability in the 2D space. Using this model we evaluated PSG data from NT1 and non-narcoleptic subjects. An LDA classifier was used to determine the best separation plane. This method replicates the specificity/sensitivity from the training set to the validation set better than many other methods. Eight prominent features could differentiate narcolepsy and controls in the validation dataset. Using a composite measure and a specificity cut off 95% in the training dataset, sensitivity was 43%. Specificity/sensitivity was 94%/38% in the validation set. Using hypersomnia subjects, specificity/sensitivity was 84%/15%. Analyzing treated narcoleptics the specificity/sensitivity was 94%/10%. Sleep stage dissociation can be used for the diagnosis of narcolepsy. However the use of some medications and presence of undiagnosed hypersomnolence patients impacts the result. Copyright © 2017 Elsevier B.V. All rights reserved.
Guerrero-Romero, Fernando; Simental-Mendía, Luis E; González-Ortiz, Manuel; Martínez-Abundis, Esperanza; Ramos-Zavala, María G; Hernández-González, Sandra O; Jacques-Camarena, Omar; Rodríguez-Morán, Martha
2010-07-01
To meet the worldwide challenge of emerging diabetes, accessible and inexpensive tests to identify insulin resistance are needed. To evaluate the sensitivity and specificity of the product of fasting, we compared the triglycerides and glucose (TyG) index, a simple measure of insulin resistance, with the euglycemic-hyperinsulinemic clamp test. We conducted a cross-sectional study of the general population and outpatients of the Internal Medicine Department at the Medical Unit of High Specialty of the Specialty Hospital at the West National Medical Center in Guadalajara, Mexico. Eleven nonobese healthy subjects, 34 obese normal glucose tolerance individuals, 22 subjects with prediabetes, and 32 diabetic patients participated in the study. We performed a euglycemic-hyperinsulinemic clamp test. Sensitivity and specificity of the TyG index [Ln(fasting triglycerides) (mg/dl) x fasting glucose (mg/dl)/2] were measured, as well as the area under the curve of the receiver operating characteristic scatter plot and the correlation between the TyG index and the total glucose metabolism (M) rates. Pearson's correlation coefficient between the TyG index and M rates was -0.681 (P < 0.005). Correlation between the TyG index and M rates was similar between men (-0.740) and women (-0.730), nonobese (-0.705) and obese (-0.710), and nondiabetic (-0.670) and diabetic (-0.690) individuals. The best value of the TyG index for diagnosis of insulin resistance was 4.68, which showed the highest sensitivity (96.5%) and specificity (85.0%; area under the curve + 0.858). The TyG index has high sensitivity and specificity, suggesting that it could be useful for identification of subjects with decreased insulin sensitivity.
Liles, Elizabeth G; Perrin, Nancy; Rosales, Ana G; Smith, David H; Feldstein, Adrianne C; Mosen, David M; Levin, Theodore R
2018-05-02
The fecal immunochemical test (FIT) is easier to use and more sensitive than the guaiac fecal occult blood test, but it is unclear how to optimize FIT performance. We compared the sensitivity and specificity for detecting advanced colorectal neoplasia between single-sample (1-FIT) and two-sample (2-FIT) FIT protocols at a range of hemoglobin concentration cutoffs for a positive test. We recruited 2,761 average-risk men and women ages 49-75 referred for colonoscopy within a large nonprofit, group-model health maintenance organization (HMO), and asked them to complete two separate single-sample FITs. We generated receiver-operating characteristic (ROC) curves to compare sensitivity and specificity estimates for 1-FIT and 2-FIT protocols among those who completed both FIT kits and colonoscopy. We similarly compared sensitivity and specificity between hemoglobin concentration cutoffs for a single-sample FIT. Differences in sensitivity and specificity between the 1-FIT and 2-FIT protocols were not statistically significant at any of the pre-specified hemoglobin concentration cutoffs (10, 15, 20, 25, and 30 μg/g). There was a significant difference in test performance of the one-sample FIT between 50 ng/ml (10 μg/g) and each of the higher pre-specified cutoffs. Disease prevalence was low. A two-sample FIT is not superior to a one-sample FIT in detection of advanced adenomas; the one-sample FIT at a hemoglobin concentration cutoff of 50 ng/ml (10 μg/g) is significantly more sensitive for advanced adenomas than at higher cutoffs. These findings apply to a population of younger, average-risk patients in a U.S. integrated care system with high rates of prior screening.
Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet
2017-04-01
Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.
Higashi, Tatsuya; Ogawa, Shoujiro
2016-09-01
Sensitive and specific methods for the detection, characterization and quantification of endogenous steroids in body fluids or tissues are necessary for the diagnosis, pathological analysis and treatment of many diseases. Recently, liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been widely used for these purposes due to its specificity and versatility. However, the ESI efficiency and fragmentation behavior of some steroids are poor, which lead to a low sensitivity. Chemical derivatization is one of the most effective methods to improve the detection characteristics of steroids in ESI-MS/MS. Based on this background, this article reviews the recent advances in chemical derivatization for the trace quantification of steroids in biological samples by LC/ESI-MS/MS. The derivatization in ESI-MS/MS is based on tagging a proton-affinitive or permanently charged moiety on the target steroid. Introduction/formation of a fragmentable moiety suitable for the selected reaction monitoring by the derivatization also enhances the sensitivity. The stable isotope-coded derivatization procedures for the steroid analysis are also described. Copyright © 2015 Elsevier Ltd. All rights reserved.
Mkony, Martha Franklin; Mizinduko, Mucho Michael; Massawe, Augustine; Matee, Mecky
2014-12-05
We determined the accuracy of Rubarth's newborn scale of sepsis and C- reactive protein in diagnosing neonatal sepsis and assessed antimicrobial susceptibility pattern of etiological bacteria. This cross sectional study was conducted at Muhimbili National Hospital in Dar es Salaam, Tanzania between July 2012 and March 2013. Neonates suspected to have sepsis underwent physical examination using Rubarth's newborn scale of sepsis (RNSOS). Blood was taken for culture and antimicrobial sensitivity testing, full blood picture and C - reactive protein (CRP) performed 12 hours apart. The efficacy of RNSOS and serial CRP was assessed by calculating sensitivity, specificity, negative and positive predictive values, receiver operating characteristics (ROC) analysis as well as likelihood ratios (LHR) with blood culture result used as a gold standard. Out of 208 blood samples, 19.2% had a positive blood culture. Single CRP had sensitivity and specificity of 87.5% and 70.9% respectively, while RNSOS had sensitivity of 65% and specificity of 79.7%. Serial CRP had sensitivity of 69.0% and specificity of 92.9%. Combination of CRP and RNSOS increased sensitivity to 95.6% and specificity of 56.4%. Combination of two CRP and RNSOS decreased sensitivity to 89.1% but increased specificity to 74%. ROC for CRP was 0.86; and for RNSOS was 0.81. For CRP the LHR for positive test was 3 while for negative test was 0.18, while for RNSOS the corresponding values were 3.24 and for negative test was 0.43. Isolated bacteria were Klebsiella spp 14 (35%), Escherichia coli 12 (22.5%), Coagulase negative staphlococci 9 (30%), Staphylococcus aureus 4 (10%), and Pseudomonas spp 1 (2.5%). The overall resistance to the WHO recommended first line antibiotics was 100%, 92% and 42% for cloxacillin, ampicillin and gentamicin, respectively. For the second line drugs resistance was 45%, 40%, and 7% for ceftriaxone, vancomycin and amikacin respectively. Single CRP in combination with RNSOS can be used for rapid identification of neonates with sepsis due to high sensitivity (95.6%) but cannot exclude those without sepsis due to low specificity (56.4%). Serial CRP done 12hrs apart can be used to exclude non-cases. This study demonstrated very high levels of resistance to the first-line antibiotics.
Asero, Riccardo
2005-09-01
Molecular biology techniques have led to the identification of a number of allergens in vegetable foods, but due to the lack of purified food proteins for routine diagnostic use, the detection of sensitizing allergens remains a nearly impossible task in most clinical settings. The allergen-resolved diagnosis of food allergy is essential because each plant-derived food may contain a number of different allergens showing different physical/chemical characteristics that strongly influence the clinical expression of allergy; moreover, many allergens may cross-react with homologue proteins present in botanically unrelated vegetable foods. Through a review of the available literature, this study aimed to detect "markers" of sensitization to specific plant food allergens that are easily accessible in the clinical practice. There are several "markers" of sensitization to different allergenic proteins in vegetable foods that can be helpful in the clinical practice. Specific algorithms for patients allergic to Rosaceae and to tree nuts were built. Clinical allergologists lacking the assistance of an advanced molecular biology lab may take advantage of some specific clinical data as well as of some "markers" in the difficult task of correctly diagnosing patients with plant food allergy and to provide them the best preventive advice. Copyright (c) 2005 S. Karger AG, Basel.
Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers.
Boelch, Sebastian Philipp; Weissenberger, Manuel; Spohn, Frederik; Rudert, Maximilian; Luedemann, Martin
2018-01-10
Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip.
You, Myung-Won; Kim, Kyung Won; Pyo, Junhee; Huh, Jimi; Kim, Hyoung Jung; Lee, So Jung; Park, Seong Ho
2017-01-01
We aimed to evaluate the correlation between liver stiffness measurement using transient elastography (TE-LSM) and hepatic venous pressure gradient and the diagnostic performance of TE-LSM in assessing clinically significant portal hypertension through meta-analysis. Eleven studies were included from thorough literature research and selection processes. The summary correlation coefficient was 0.783 (95% confidence interval [CI], 0.737-0.823). Summary sensitivity, specificity and area under the hierarchical summary receiver operating characteristic curve (AUC) were 87.5% (95% CI, 75.8-93.9%), 85.3 % (95% CI, 76.9-90.9%) and 0.9, respectively. The subgroup with low cut-off values of 13.6-18 kPa had better summary estimates (sensitivity 91.2%, specificity 81.3% and partial AUC 0.921) than the subgroup with high cut-off values of 21-25 kPa (sensitivity 71.2%, specificity 90.9% and partial AUC 0.769). In summary, TE-LSM correlated well with hepatic venous pressure gradient and represented good diagnostic performance in diagnosing clinically significant portal hypertension. For use as a sensitive screening tool, we propose using low cut-off values of 13.6-18 kPa in TE-LSM. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Diagnostic value of highly-sensitive chimerism analysis after allogeneic stem cell transplantation.
Sellmann, Lea; Rabe, Kim; Bünting, Ivonne; Dammann, Elke; Göhring, Gudrun; Ganser, Arnold; Stadler, Michael; Weissinger, Eva M; Hambach, Lothar
2018-05-02
Conventional analysis of host chimerism (HC) frequently fails to detect relapse before its clinical manifestation in patients with hematological malignancies after allogeneic stem cell transplantation (allo-SCT). Quantitative PCR (qPCR)-based highly-sensitive chimerism analysis extends the detection limit of conventional (short tandem repeats-based) chimerism analysis from 1 to 0.01% host cells in whole blood. To date, the diagnostic value of highly-sensitive chimerism analysis is hardly defined. Here, we applied qPCR-based chimerism analysis to 901 blood samples of 71 out-patients with hematological malignancies after allo-SCT. Receiver operating characteristics (ROC) curves were calculated for absolute HC values and for the increments of HC before relapse. Using the best cut-offs, relapse was detected with sensitivities of 74 or 85% and specificities of 69 or 75%, respectively. Positive predictive values (PPVs) were only 12 or 18%, but the respective negative predictive values were 98 or 99%. Relapse was detected median 38 or 45 days prior to clinical diagnosis, respectively. Considering also durations of steadily increasing HC of more than 28 days improved PPVs to more than 28 or 59%, respectively. Overall, highly-sensitive chimerism analysis excludes relapses with high certainty and predicts relapses with high sensitivity and specificity more than a month prior to clinical diagnosis.
Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.
2015-01-01
Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400
2011-01-01
Background Pemphigoids are rare diseases associated with IgG, IgE and IgA autoantibodies against collagen XVII/BP180. An entity of the pemphigoid group is the lamina lucida-type of linear IgA disease (IgA pemphigoid) characterized by IgA autoantibodies against BP180. While for the detection of IgG and IgE autoantibodies specific to collagen XVII several ELISA systems have been established, no quantitative immunoassay has been yet developed for IgA autoantibodies. Therefore, the aim of the present study was to develop an ELISA to detect IgA autoantibodies against collagen XVII in the sera of patients with pemphigoids. Methods We expressed a soluble recombinant form of the collagen XVII ectodomain in mammalian cells. Reactivity of IgA autoantibodies from patients with IgA pemphigoid was assessed by immunofluorescence microscopy and immunoblot analysis. ELISA test conditions were determined by chessboard titration experiments. The sensitivity, specificity and the cut-off were determined by receiver-operating characteristics analysis. Results The optimized assay was carried out using sera from patients with IgA pemphigoid (n = 30) and healthy donors (n = 105). By receiver operating characteristics (ROC) analysis, an area under the curve of 0.993 was calculated, indicating an excellent discriminatory capacity. Thus, a sensitivity and specificity of 83.3% and 100%, respectively, was determined for a cut-off point of 0.48. As additional control groups, sera from patients with bullous pemphigoid (n = 31) and dermatitis herpetiformis (n = 50), a disease associated with IgA autoantibodies against epidermal transglutaminase, were tested. In 26% of bullous pemphigoid patients, IgA autoantibodies recognized the ectodomain of collagen XVII. One of 50 (2%) of dermatitis herpetiformis patients sera slightly topped the cut-off value. Conclusions We developed the first ELISA for the specific and sensitive detection of serum IgA autoantibodies specific to collagen XVII in patients with pemphigoids. This immunoassay should prove a useful tool for clinical and translational research and should essentially improve the diagnosis and disease monitoring of patients with IgA pemphigoid. Moreover, our findings strongly suggest that IgA pemphigoid and IgG bullous pemphigoid represent two ends of the clinical spectrum of an immunological loss of tolerance against components of hemidesmosomes, which is mediated by both IgG and IgA autoantibodies. PMID:21619684
Modified Organosilica Core-Shell Nanoparticles for Stable pH Sensing in Biological Solutions.
Robinson, Kye J; Huynh, Gabriel T; Kouskousis, Betty P; Fletcher, Nicholas L; Houston, Zachary H; Thurecht, Kristofer J; Corrie, Simon R
2018-04-19
Continuous monitoring using nanoparticle-based sensors has been successfully employed in complex biological systems, yet the sensors still suffer from poor long-term stability partially because of the scaffold materials chosen to date. Organosilica core-shell nanoparticles containing a mixture of covalently incorporated pH-sensitive (shell) and pH-insensitive (core) fluorophores is presented as a continuous pH sensor for application in biological media. In contrast to previous studies focusing on similar materials, we sought to investigate the sensor characteristics (dynamic range, sensitivity, response time, stability) as a function of material properties. The ratio of the fluorescence intensities at specific wavelengths was found to be highly sensitive to pH over a physiologically relevant range (4.5-8) with a response time of <100 ms, significantly faster than that of previously reported response times using silica-based particles. Particles produced stable, pH-specific signals when stored at room temperature for more than 80 days. Finally, we demonstrated that the nanosensors successfully monitored the pH of a bacterial culture over 15 h and that pH changes in the skin of mouse cadavers could also be observed via in vivo fluorescence imaging following subcutaneous injection. The understanding gained from linking sensor characteristics and material properties will inform the next generation of optical nanosensors for continuous-monitoring applications.
Vyas, Nikki S; Pierce Campbell, Christine M; Mathew, Rahel; Abrahamsen, Martha; Van der Kooi, Kaisa; Jukic, Drazen M; Stoler, Mark H; Villa, Luisa L; da Silva, Roberto Carvalho; Lazcano-Ponce, Eduardo; Quiterio, Manuel; Salmeron, Jorge; Sirak, Bradley A; Ingles, Donna J; Giuliano, Anna R; Messina, Jane L
2015-10-01
Early HPV infection in males is difficult to detect clinically and pathologically. This study assessed histopathology in diagnosing male genital HPV. External genital lesions (n = 352) were biopsied, diagnosed by a dermatopathologist, and HPV genotyped. A subset (n = 167) was diagnosed independently by a second dermatopathologist and also re-evaluated in detail, tabulating the presence of a set of histopathologic characteristics related to HPV infection. Cases that received discrepant diagnoses or HPV-related diagnoses were evaluated by a third dermatopathologist (n = 163). Across dermatopathologists, three-way concordance was fair (k = 0.30). Pairwise concordance for condyloma was fair to good (k = 0.30-0.67) and poor to moderate for penile intraepithelial neoplasia (k = -0.05 to 0.42). Diagnoses were 44-47% sensitive and 65-72% specific for HPV 6/11-containing lesions, and 20-37% sensitive and 98-99% specific for HPV 16/18. Presence of HPV 6/11 was 75-79% sensitive and 35% specific for predicting pathologic diagnosis of condyloma. For diagnosis of penile intraepithelial neoplasia, HPV 16/18 was 95-96% specific but only 40-64% sensitive. Rounded papillomatosis, hypergranulosis, and dilated vessels were significantly (P < 0.05) associated with HPV 6/11. Dysplasia was significantly (P = 0.001) associated with HPV 16/18. Dermatopathologists' diagnoses of early male genital HPV-related lesions appear discordant with low sensitivity, while genotyping may overestimate clinically significant HPV-related disease. Rounded papillomatosis, hypergranulosis, and dilated vessels may help establish diagnosis of early condyloma. © 2015 Wiley Periodicals, Inc.
Vyas, Nikki S.; Pierce Campbell, Christine M.; Mathew, Rahel; Abrahamsen, Martha; Van der Kooi, Kaisa; Jukic, Drazen M.; Stoler, Mark H.; Villa, Luisa L.; da Silva, Roberto Carvalho; Lazcano-Ponce, Eduardo; Quiterio, Manuel; Salmeron, Jorge; Sirak, Bradley A.; Ingles, Donna J.; Giuliano, Anna R.; Messina, Jane L.
2016-01-01
Early HPV infection in males is difficult to detect clinically and pathologically. This study assessed histopathology in diagnosing male genital HPV. External genital lesions (n = 352) were biopsied, diagnosed by a dermatopathologist, and HPV genotyped. A subset (n = 167) was diagnosed independently by a second dermatopathologist and also re-evaluated in detail, tabulating the presence of a set of histopathologic characteristics related to HPV infection. Cases that received discrepant diagnoses or HPV-related diagnoses were evaluated by a third dermatopathologist (n = 163). Across dermatopathologists, three-way concordance was fair (k = 0.30). Pairwise concordance for condyloma was fair to good (k = 0.30–0.67) and poor to moderate for penile intraepithelial neoplasia (k = −0.05 to 0.42). Diagnoses were 44–47% sensitive and 65–72% specific for HPV 6/ 11-containing lesions, and 20–37% sensitive and 98–99% specific for HPV 16/18. Presence of HPV 6/ 11 was 75–79% sensitive and 35% specific for predicting pathologic diagnosis of condyloma. For diagnosis of penile intraepithelial neoplasia, HPV 16/18 was 95–96% specific but only 40–64% sensitive. Rounded papillomatosis, hypergranulosis, and dilated vessels were significantly (P<0.05) associated with HPV 6/11. Dysplasia was significantly (P= 0.001) associated with HPV 16/18. Dermatopathologists’ diagnoses of early male genital HPV-related lesions appear discordant with low sensitivity, while genotyping may overestimate clinically significant HPV-related disease. Rounded papillomatosis, hypergranulosis, and dilated vessels may help establish diagnosis of early condyloma. PMID:25945468
Rumpf, Hans-Jürgen; Hapke, Ulfert; Meyer, Christian; John, Ulrich
2002-01-01
Most screening questionnaires are developed in clinical settings and there are few data on their performance in the general population. This study provides data on the area under the receiver-operating characteristic (ROC) curve, sensitivity, specificity, and internal consistency of the Alcohol Use Disorders Identification Test (AUDIT), the consumption questions of the AUDIT (AUDIT-C) and the Lübeck Alcohol Dependence and Abuse Screening Test (LAST) among current drinkers (n = 3551) of a general population sample in northern Germany. Alcohol dependence and misuse according to DSM-IV and at-risk drinking served as gold standards to assess sensitivity and specificity and were assessed with the Munich-Composite Diagnostic Interview (M-CIDI). AUDIT and LAST showed insufficient sensitivity for at-risk drinking and alcohol misuse using standard cut-off scores, but satisfactory detection rates for alcohol dependence. The AUDIT-C showed low specificity in all criterion groups with standard cut-off. Adjusted cut-points are recommended. Among a subsample of individuals with previous general hospital admission in the last year, all questionnaires showed higher internal consistency suggesting lower reliability in non-clinical samples. In logistic regression analyses, having had a hospital admission increased the sensitivity in detecting any criterion group of the LAST, and the number of recent general practice visits increased the sensitivity of the AUDIT in detecting alcohol misuse. Women showed lower scores and larger areas under the ROC curves. It is concluded that setting specific instruments (e.g. primary care or general population) or adjusted cut-offs should be used.
Galvin, Pamela; Gildea, Sarah; Nelly, Maura; Quinlivan, Michelle; Arkins, Sean; Walsh, Cathal; Cullinane, Ann
2014-05-01
Equine influenza (EI) is a highly contagious respiratory disease of horses. The aim of this study was to evaluate two rapid antigen detection kits (Directigen or DFA, and Espline) and a commercial ELISA for the detection of EI nucleoprotein in nasal swabs. Nasal swab samples from naturally and experimentally infected horses were used to compare the sensitivity and specificity of these assays to virus isolation (VI) and real-time RT-PCR. If real-time RT-PCR was considered as the gold standard, the sensitivity of the other tests in field samples was 68% (DFA), 35% (ELISA), 29% (Espline), and 9% (VI). These tests had 100% specificity when compared to real-time RT-PCR. A receiver operating characteristic (ROC) curve indicated that decreasing the cutoff of the ELISA would increase sensitivity with some loss of specificity. In samples from experimentally infected horses, the sensitivity of the tests compared with real-time RT-PCR was 69% (VI), 27% (DFA), 6% (Espline), and 2% (ELISA). The specificity was 100% for Espline and ELISA and 95% for VI and DFA. This study illustrated that DFA is the most sensitive antigen detection test evaluated for the diagnosis of EI and that it can detect virus in some subclinical infected and vaccinated horses. The results suggest that DFA is a useful adjunct to laboratory tests and may be effective as a screening test in a quarantine station or similar facility where horses are monitored daily. © 2014 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Nagai, Takashi; Taya, Kiyoshi; Yoda, Ikuko
2016-02-01
The authors used 5 species of periphytic algae to conduct toxicity assays of 20 herbicides. The 5 tested species represent riverine primary producers most likely to be affected by herbicides. A fluorescence microplate toxicity assay was used as an efficient and economical high-throughput assay. Toxicity characteristics were analyzed, focusing on their relationship to herbicide mode of action. The relative differences between 50% and 10% effect concentrations depended on herbicide mode of action, rather than tested species. Moreover, a clear relationship between sensitive species and herbicide mode of action was also observed. Green alga was most sensitive to herbicides of 2 mode of action groups: inhibitors of protoporphyrinogen oxidase and very long-chain fatty acid synthesis. Diatoms were most sensitive to herbicides of 1 mode of action group: 4-hydroxyphenyl-pyruvate-dioxygenase inhibitors. Cyanobacterium was most sensitive to herbicides of 1 mode of action group: inhibitors of acetolactate synthase. The species sensitivity distribution based on obtained data was also analyzed. The slopes of the species sensitivity distribution significantly differed among modes of action, suggesting that difference in species sensitivity is specific to the mode of action. In particular, differences in species sensitivity were markedly large for inhibitors of acetolactate synthase, protoporphyrinogen oxidase, and very long-chain fatty acid synthesis. The results clearly showed that a single algal species cannot represent the sensitivity of an algal assemblage. Therefore, multispecies algal toxicity data are essential for substances with specific modes of action. © 2015 SETAC.
ERIC Educational Resources Information Center
Sherman, Tracy; Shulman, Brian B.
1999-01-01
This study examined test characteristics of the Pediatric Language Acquisition Screening Tool for Early Referral-Revised (PLASTER-R), a set of developmental questionnaires for children 3 to 60 months of age. The PLASTER-R was moderately to highly successful in identifying children within normal limits for language development. Test-retest…
Comparison of different cardiac relaxation indices.
Alipov, N N; Izrail'tyan, I M; Sokolov, A V; Trubetskaya, L V; Kuznetsova, T E
2001-05-01
Sensitivity (response to epinephrine infusion) and specificity (response to changes in pre- and afterload) of some cardiac relaxation indices were compared in acute experiments on cats treated with ganglionic blocker arfonad. Some new indices proposed by us provide better characteristics than widely used relaxation time constant (t) and maximum first derivative of the left ventricular pressure (-dP/dt)max.
USDA-ARS?s Scientific Manuscript database
Lateral flow devices (LFD) are commercially available and provide a fast, highly specific, on-site test for avian influenza. Because of the low analytic sensitivity of LFD tests at low virus concentrations, targeted sampling of sick and dead birds has been proposed in order to increase detection pr...
Azabou, Eric; Fischer, Catherine; Mauguiere, François; Vaugier, Isabelle; Annane, Djillali; Sharshar, Tarek; Lofaso, Fréderic
2016-01-01
We prospectively studied early bedside standard EEG characteristics in 61 acute postanoxic coma patients. Five simple EEG features, namely, isoelectric, discontinuous, nonreactive to intense auditory and nociceptive stimuli, dominant delta frequency, and occurrence of paroxysms were classified yes or no. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and area under the receiver operating characteristic curve (AUC) of each of these variables for predicting an unfavorable outcome, defined as death, persistent vegetative state, minimally conscious state, or severe neurological disability, as assessed 1 year after coma onset were computed as well as Synek's score. The outcome was unfavorable in 56 (91.8%) patients. Sensitivity, specificity, PPV, NPV, and AUC of nonreactive EEG for predicting an unfavorable outcome were 84%, 80%, 98%, 31%, and 0.82, respectively; and were all very close to the ones of Synek score>3, which were 82%, 80%, 98%, 29%, and 0.81, respectively. Specificities for predicting an unfavorable outcome were 100% for isoelectric, discontinuous, or dominant delta activity EEG. These 3 last features were constantly associated to unfavorable outcome. Absent EEG reactivity strongly predicted an unfavorable outcome in postanoxic coma, and performed as accurate as a Synek score>3. Analyzing characteristics of some simple EEG features may easily help nonneurophysiologist physicians to investigate prognostic issue of postanoxic coma patient. In this study (a) discontinuous, isoelectric, or delta-dominant EEG were constantly associated with unfavorable outcome and (b) nonreactive EEG performed prognostic as accurate as a Synek score>3. © EEG and Clinical Neuroscience Society (ECNS) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baliatsas, Christos, E-mail: c.baliatsas@nivel.nl
Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and sensitivity to electromagnetic fields (EMF). A cross-sectional study performed in the Netherlands, combining self-administered questionnaires and electronic medical records of non-specific symptoms (NSS) registered by general practitioners (GP) allowed us to explore this further. The study sample consisted of 5806 participants, drawn from 21 general practices. Among participants, 722 (12.5%) responded “absolutely agree” to the statement “I am sensitive tomore » noise”, comprising the high noise-sensitive (HNS) group. Compared to the rest of the sample, people in the HNS group reported significantly higher scores on number and duration of self-reported NSS, increased psychological distress, decreased sleep quality and general health, more negative symptom perceptions and higher prevalence of healthcare contacts, GP-registered NSS and prescriptions for antidepressants and benzodiazepines. These results remained robust after adjustment for demographic, residential and lifestyle characteristics, objectively measured nocturnal noise exposure from road-traffic and GP-registered morbidity. Co-occurrence rates with other environmental sensitivities varied between 9% and 50%. Individuals with self-declared sensitivity to noise are characterized by high prevalence of multiple NSS, poorer health status and increased illness behavior independently of noise exposure levels. Findings support the notion that different types of environmental sensitivities partly overlap. - Highlights: • People with self-reported noise sensitivity experience multiple non-specific symptoms. • They also report comparatively poorer health and increased illness behavior. • Co-occurrence with other environmental sensitivities is moderate to high. • Road-traffic noise and GP-registered morbidity did not account for these results.« less
Pugliese, Cara E; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B; White, Susan W; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D; Schultz, Robert T; Martin, Alex; Anthony, Laura Gutermuth
2015-12-01
Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility.
Kostić, Tanja; Sessitsch, Angela
2011-01-01
Reliable and sensitive pathogen detection in clinical and environmental (including food and water) samples is of greatest importance for public health. Standard microbiological methods have several limitations and improved alternatives are needed. Most important requirements for reliable analysis include: (i) specificity; (ii) sensitivity; (iii) multiplexing potential; (iv) robustness; (v) speed; (vi) automation potential; and (vii) low cost. Microarray technology can, through its very nature, fulfill many of these requirements directly and the remaining challenges have been tackled. In this review, we attempt to compare performance characteristics of the microbial diagnostic microarrays developed for the detection and typing of food and water pathogens, and discuss limitations, points still to be addressed and issues specific for the analysis of food, water and environmental samples. PMID:27605332
White, Brad J; Goehl, Dan R; Amrine, David E; Booker, Calvin; Wildman, Brian; Perrett, Tye
2016-04-01
Accurate diagnosis of bovine respiratory disease (BRD) in beef cattle is a critical facet of therapeutic programs through promotion of prompt treatment of diseased calves in concert with judicious use of antimicrobials. Despite the known inaccuracies, visual observation (VO) of clinical signs is the conventional diagnostic modality for BRD diagnosis. Objective methods of remotely monitoring cattle wellness could improve diagnostic accuracy; however, little information exists describing the accuracy of this method compared to traditional techniques. The objective of this research is to employ Bayesian methodology to elicit diagnostic characteristics of conventional VO compared to remote early disease identification (REDI) to diagnose BRD. Data from previous literature on the accuracy of VO were combined with trial data consisting of direct comparison between VO and REDI for BRD in two populations. No true gold standard diagnostic test exists for BRD; therefore, estimates of diagnostic characteristics of each test were generated using Bayesian latent class analysis. Results indicate a 90.0% probability that the sensitivity of REDI (median 81.3%; 95% probability interval [PI]: 55.5, 95.8) was higher than VO sensitivity (64.5%; PI: 57.9, 70.8). The specificity of REDI (median 92.9%; PI: 88.2, 96.9) was also higher compared to VO (median 69.1%; PI: 66.3, 71.8). The differences in sensitivity and specificity resulted in REDI exhibiting higher positive and negative predictive values in both high (41.3%) and low (2.6%) prevalence situations. This research illustrates the potential of remote cattle monitoring to augment conventional methods of BRD diagnosis resulting in more accurate identification of diseased cattle. Copyright © 2016 Elsevier B.V. All rights reserved.
Martí Gamboa, Sabina; Giménez, Olga Redrado; Mancho, Jara Pascual; Moros, María Lapresta; Sada, Julia Ruiz; Mateo, Sergio Castan
2017-04-01
Objective The objective of this study was to determine ability to detect neonatal acidemia and interobserver agreement with the FIGO 3-tier and 5-tier fetal heart rate (FHR) classification systems. Design This was a case-control study. Setting This study was set at the University Medical Center. Population A total of 202 FHR tracings of 102 women who delivered an acidemic fetus (umbilical arterial cord gas pH ≤ 7.10 and BE < - 8) and 100 who delivered a nonacidemic fetus (umbilical arterial cord gas pH > 7.10) were assessed. A subanalysis was performed for those fetuses who suffered severe metabolic acidemia (pH ≤ 7.0 and BE < - 12). Methods Two reviewers blind to clinical and outcome data classified tracings according to the new 3-tier system proposed by the FIGO and the 5-tier system proposed by Parer and Ikeda. Main Outcome Measures Sensitivity and specificity for detecting neonatal acidemia and interobserver agreement in classifying FHR tracings into categories of both systems were studied. Results The 3-tier system showed a greater sensitivity and lower specificity to detect neonatal acidemia (43.6% sensitivity, 82.5% specificity) and severe metabolic acidemia (71.4% sensitivity, 74.0% specificity) compared with the 5-tier system (36.3% sensitivity, 88% specificity and 61.9% sensitivity, 80.1% specificity, respectively). Both systems were compared by area under the receiver-operating characteristic curve, with comparable predictive ability for detecting neonatal acidemia (FIGO-area under the curve [AUC]: 0.63 [95% confidence interval [CI]: 0.57-0.68] and Parer-AUC: 0.62 [95% CI: 0.56-0.67]). Interobserver agreement was moderate for both systems, but performance at each specific category showed a better agreement for the 5-tier system identifying a pathological tracing (orange or red, κ: 0.625 vs. pathological category, κ: 0.538). Conclusion Both systems presented a comparable ability to predict neonatal acidemia, although the 5-tier system showed a better interobserver agreement identifying pathological tracings. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Kennedy, Mark; Betts, Lucy R; Underwood, Jean D M
2014-01-01
Attachment theory asserts that secure attachment representations are developed through sensitive and consistent caregiving. If sensitive caregiving is a constant characteristic of the parent, then siblings should have concordant attachment classifications. The authors explored maternal attachment quality assessed by the Attachment Q-Set, maternal sensitivity, and specific mother-child interactions between siblings. Hour-long observations took place in the homes of 9 preschool sibling pairs and their immediate caregivers. The interactions were analyzed using a modified version of Bales' Small Group Analysis. The results reveal attachment discordance in a third of sibling pairs. While maternal sensitivity was higher with older siblings and mothers displayed more positive emotions when interacting with their younger siblings, attachment quality was not associated with birth order. Therefore, a shift toward a more contextual, family-based perspective of attachment is recommended to further understand how attachment strategies are created and maintained within the child's everyday context.
Macular Diagnostic Ability in OCT for Assessing Glaucoma in High Myopia.
Hung, Kuo-Chi; Wu, Pei-Chang; Poon, Yi-Chieh; Chang, Hsueh-Wen; Lai, Ing-Chou; Tsai, Jen-Chia; Lin, Pei-Wen; Teng, Mei-Ching
2016-02-01
To compare the diagnostic abilities of spectral-domain optical coherence tomography (SD-OCT; Spectralis OCT) and time-domain OCT (TD-OCT; Stratus OCT). Changes in macular parameters in highly myopic eyes of glaucoma patients and highly myopic eyes of glaucoma suspects were evaluated and compared. We collected data from 72 highly myopic eyes (spherical equivalent, ≤-6.0D). Forty-one eyes had perimetric glaucoma and 31 eyes were suspected to have glaucoma (control group). All eyes underwent SD-OCT and TD-OCT imaging. Area under the receiver operating characteristic (AUROC) curve and sensitivity were examined on macular volume and thickness parameters at a fixed specificity and compared between groups. The highest TD-OCT AUROC curves were found using outer inferior sector macular thickness (AUROC curve, 0.911) and volume (AUROC curve, 0.909). The highest SD-OCT AUROC curves were found using outer inferior region thickness (AUROC curve, 0.836) and volume (AUROC curve, 0.834). The difference between the two imaging modalities was not statistically significant (thickness, p = 0.141; volume, p = 0.138). The sensitivity of TD-OCT macular outer inferior average thickness was highest and was 88.2%, with a specificity of 80.4%. The sensitivity of TD-OCT average volume measurements in this same region was 76.5%, with a specificity of 91.3%. The SD-OCT average thickness measurements also had the highest sensitivity in this region, which was 78.6%, with a specificity of 82.1%. The SD-OCT volume measurements had a sensitivity of 67.9%, with a specificity of 92.3%. Both SD-OCT and TD-OCT measurements of outer inferior macular thickness and volume can differentiate between eyes of glaucoma patients and glaucoma suspects with high myopia. These independent predictors all had good sensitivity. Based on our results, SD-OCT and TD-OCT have similar diagnostic abilities. These parameters may provide useful additional data in highly myopic eyes to complement standard glaucoma diagnosis tools.
van't Hoog, Anna H; Cobelens, Frank; Vassall, Anna; van Kampen, Sanne; Dorman, Susan E; Alland, David; Ellner, Jerrold
2013-01-01
High costs are a limitation to scaling up the Xpert MTB/RIF assay (Xpert) for the diagnosis of tuberculosis in resource-constrained settings. A triaging strategy in which a sensitive but not necessarily highly specific rapid test is used to select patients for Xpert may result in a more affordable diagnostic algorithm. To inform the selection and development of particular diagnostics as a triage test we explored combinations of sensitivity, specificity and cost at which a hypothetical triage test will improve affordability of the Xpert assay. In a decision analytical model parameterized for Uganda, India and South Africa, we compared a diagnostic algorithm in which a cohort of patients with presumptive TB received Xpert to a triage algorithm whereby only those with a positive triage test were tested by Xpert. A triage test with sensitivity equal to Xpert, 75% specificity, and costs of US$5 per patient tested reduced total diagnostic costs by 42% in the Uganda setting, and by 34% and 39% respectively in the India and South Africa settings. When exploring triage algorithms with lower sensitivity, the use of an example triage test with 95% sensitivity relative to Xpert, 75% specificity and test costs $5 resulted in similar cost reduction, and was cost-effective by the WHO willingness-to-pay threshold compared to Xpert for all in Uganda, but not in India and South Africa. The gain in affordability of the examined triage algorithms increased with decreasing prevalence of tuberculosis among the cohort. A triage test strategy could potentially improve the affordability of Xpert for TB diagnosis, particularly in low-income countries and with enhanced case-finding. Tests and markers with lower accuracy than desired of a diagnostic test may fall within the ranges of sensitivity, specificity and cost required for triage tests and be developed as such.
Jankásková, J; Horváth, O N; Varga, R; Arenberger, P; Schmidt, E; Ruzicka, T; Sárdy, M
2018-04-01
Indirect immunofluorescence (IIF) microscopy on monkey oesophagus is an important assay for the diagnosis of bullous pemphigoid (BP). Its relatively low sensitivity (60-80%) may be partly due to insufficient detection of minor IgG subclasses. To determine the operating characteristics of an IgG subclass in IIF. We designed a retrospective, dual-centre, controlled cohort study on sera from 64 BP sera that had been rated as false negatives by traditional IIF microscopy, and assessed circulating IgG 1 , IgG 3 and IgG 4 autoantibodies. The sensitivities of IIF in detecting IgG 1 , IgG 3 , IgG 4 and all three in combination were 45.3%, 18.8%, 32.8% and 48.4%, respectively. Specificities were > 97%. Detection of IgG subclass (especially IgG 1 and IgG 4 ) autoantibodies by IIF on monkey oesophagus can significantly improve diagnostic performance of IIF microscopy for diagnosis of BP. © 2018 British Association of Dermatologists.
Lu, L; Chen, J H; Zhu, H J; Song, A L; Li, M; Chen, S; Pan, H; Gong, F Y; Wang, R Z; Xing, B; Yao, Y; Feng, M; Lu, Z L
2016-07-19
To compare the sensitivity and specificity between the 24 hour urine free cortisol (24 h UFC) and serum cortisol in dexamethasone suppression test (DST) in the diagnosis of Cushing syndrome (CS). Combined low dose DST (LDDST) and high dose DST (HDDST) were carried out in 67 cases of CS with surgically confirmed cases in recent 3 years(from January 2011 to November 2015). The serum cortisol and 24 h UFC were collected simultaneously for each subject and the sensitivity and specificity of serum cortisol and 24 h UFC were compared. There were Cushing disease (CD) group (n=53), ectopic adrenocorticotropic hormone (ACTH) syndrome group (n=7) and ACTH-independent Cushing syndrome group (n=7) according to the etiology of hypercorticordism.There were no significant differences among 3 groups in gender and age.The sensitivity of serum cortisol of different cut off points(50, 110, 140 nmol/L and 50% of control)after LDDST was 97.01%, 86.57%, 83.58% and 70.15% respectively.Meanwhile, the sensitivity of cutoff point of 24 h UFC <32 nmol in combined LDDST was 92.54% in the diagnosis of Cushing syndrome.There was no significant differences in two groups between serum cortisol <110 nmol/L and 24 h UFC <32 nmol.However, the sensitivity of serum cortisol <50 nmol/L was significantly higher than 24 h UFC<32 nmol (P<0.05). Furthermore, in combined HDDST, if the suppression rate was ≥50%, the sensitivity of serum cortisol and 24 h UFC in differentiating the etiology of Cushing disease was 60.38% and 90.57%, and the specificity was 91.43% and 96.00% respectively.There were significant differences between serum cortisol and 24 h UFC in both of sensitivity and specificity (both P<0.05). In addition, if the suppression rate of 24 h UFC in HDDST was adjusted to 60.85% according to receiver operating characteristic (ROC) curve, it could have the best levels of sensitivity (92.6%) with the specificity of 85.7%. If the suppression rate of serum cortisol was adjusted to 61.53% in HDDST according to ROC curve, it could have the best sensitivity (64.8%) with the specificity of 78.6% accordingly. In combined LDDST, the serum cortisol <50 nmol/L had a higher sensitivity than the 24 h UFC<32 nmol when they were used as the criteria in determining the diagnosis of CS.In HDDST, the sensitivity and specificity of suppression rate of 24 h UFC ≥50% were better than serum cortisol to differentiate the etiology of CS.
Rahman, Md Toufiq; Codlin, Andrew J; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera; Creswell, Jacob
2017-05-01
Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert).Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receiver operating characteristic curve (AUC), and calculated the potential Xpert tests saved.A total of 18 036 individuals were enrolled. TB prevalence by Xpert was 15%. The radiologist graded 49% of CXRs as abnormal, resulting in 91% sensitivity and 58% specificity. At a similar sensitivity, CAR had a lower specificity (41%), saving fewer (36%) Xpert tests. The AUC for CAR was 0.74 (95% CI 0.73-0.75). CAR performance declined with increasing age. The radiologist grading was superior across all sub-analyses.Using CAR can save Xpert tests, but the radiologist's specificity was superior. Differentiated CAR thresholds may be required for different populations. Access to, and costs of, human readers must be considered when deciding to use CAR software. More studies are needed to evaluate CAR using different screening approaches. Copyright ©ERS 2017.
Rahman, Md Toufiq; Codlin, Andrew J.; Rahman, Md Mahfuzur; Nahar, Ayenun; Reja, Mehdi; Islam, Tariqul; Qin, Zhi Zhen; Khan, Md Abdus Shakur; Banu, Sayera
2017-01-01
Computer-aided reading (CAR) of medical images is becoming increasingly common, but few studies exist for CAR in tuberculosis (TB). We designed a prospective study evaluating CAR for chest radiography (CXR) as a triage tool before Xpert MTB/RIF (Xpert). Consecutively enrolled adults in Dhaka, Bangladesh, with TB symptoms received CXR and Xpert. Each image was scored by CAR and graded by a radiologist. We compared CAR with the radiologist for sensitivity and specificity, area under the receiver operating characteristic curve (AUC), and calculated the potential Xpert tests saved. A total of 18 036 individuals were enrolled. TB prevalence by Xpert was 15%. The radiologist graded 49% of CXRs as abnormal, resulting in 91% sensitivity and 58% specificity. At a similar sensitivity, CAR had a lower specificity (41%), saving fewer (36%) Xpert tests. The AUC for CAR was 0.74 (95% CI 0.73–0.75). CAR performance declined with increasing age. The radiologist grading was superior across all sub-analyses. Using CAR can save Xpert tests, but the radiologist's specificity was superior. Differentiated CAR thresholds may be required for different populations. Access to, and costs of, human readers must be considered when deciding to use CAR software. More studies are needed to evaluate CAR using different screening approaches. PMID:28529202
Hu, Yaomin; Liu, Wei; Chen, Yawen; Zhang, Ming; Wang, Lihua; Zhou, Huan; Wu, Peihong; Teng, Xiangyu; Dong, Ying; Zhou, Jia wen; Xu, Hua; Zheng, Jun; Li, Shengxian; Tao, Tao; Hu, Yumei; Jia, Yun
2010-09-01
The aim of this study is to assess the validity of combined use of fasting plasma glucose (FPG) and glycated hemoglobin A1c (HbA1c) as screening tests for diabetes and impaired glucose tolerance (IGT) in high-risk subjects. A total of 2,298 subjects were included. All subjects underwent a 75-g oral glucose tolerance test (OGTT) and HbA1c measurement. Receiver operating characteristic curve (ROC curve) analysis was used to examine the sensitivity and specificity of FPG and HbA1c for detecting diabetes and IGT, which was defined according to the 1999 World Health Organization (WHO) criteria. (1) Based on the ROC curve, the optimal cut point of FPG related to diabetes diagnosed by OGTT was 6.1 mmol/l that was associated with a sensitivity and specificity of 81.5 and 81.0%, respectively; The optimal cut point of HbA1c related to diabetes diagnosed by OGTT was 6.1%, which was associated with a sensitivity and specificity of 81.0 and 81.0%, respectively; The screening model using FPG > or = 6.1 mmol/l or HbA1c > or = 6.1% had sensitivity of 96.5% for detecting undiagnosed diabetes; the screening model using FPG > or = 6.1 mmol/l and HbA1c > or = 6.1% had specificity of 96.3% for detecting undiagnosed diabetes. (2) Based on the ROC curve, the optimal cut point of FPG related to IGT diagnosed by OGTT was 5.6 mmol/l that was associated with a sensitivity and specificity of 64.1 and 65.4%, respectively; The optimal cut point of HbA1c related to IGT diagnosed by OGTT was 5.6%, which was associated with a sensitivity and specificity of 66.2 and 51.0%, respectively; The screening model using FPG > or = 5.6 mmol/l or HbA1c > or = 5.6% had sensitivity of 87.9% for detecting undiagnosed IGT; The screening model using FPG > or = 5.6 mmol/l and HbA1c > or = 5.6% had specificity of 82.4% for detecting undiagnosed IGT. Compared with FPG or HbA1c alone, the simultaneous measurement of FPG and HbA1c (FPG and/or HbA1C) might be a more sensitive and specific screening tool for identifying high-risk individuals with diabetes and IGT at an early stage.
Lee, Ho-Won; Muniyappa, Ranganath; Yan, Xu; Yue, Lilly Q.; Linden, Ellen H.; Chen, Hui; Hansen, Barbara C.
2011-01-01
The euglycemic glucose clamp is the reference method for assessing insulin sensitivity in humans and animals. However, clamps are ill-suited for large studies because of extensive requirements for cost, time, labor, and technical expertise. Simple surrogate indexes of insulin sensitivity/resistance including quantitative insulin-sensitivity check index (QUICKI) and homeostasis model assessment (HOMA) have been developed and validated in humans. However, validation studies of QUICKI and HOMA in both rats and mice suggest that differences in metabolic physiology between rodents and humans limit their value in rodents. Rhesus monkeys are a species more similar to humans than rodents. Therefore, in the present study, we evaluated data from 199 glucose clamp studies obtained from a large cohort of 86 monkeys with a broad range of insulin sensitivity. Data were used to evaluate simple surrogate indexes of insulin sensitivity/resistance (QUICKI, HOMA, Log HOMA, 1/HOMA, and 1/Fasting insulin) with respect to linear regression, predictive accuracy using a calibration model, and diagnostic performance using receiver operating characteristic. Most surrogates had modest linear correlations with SIClamp (r ≈ 0.4–0.64) with comparable correlation coefficients. Predictive accuracy determined by calibration model analysis demonstrated better predictive accuracy of QUICKI than HOMA and Log HOMA. Receiver operating characteristic analysis showed equivalent sensitivity and specificity of most surrogate indexes to detect insulin resistance. Thus, unlike in rodents but similar to humans, surrogate indexes of insulin sensitivity/resistance including QUICKI and log HOMA may be reasonable to use in large studies of rhesus monkeys where it may be impractical to conduct glucose clamp studies. PMID:21209021
Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography.
Ernst, Marielle; Romero, Javier M; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael
2015-01-01
The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54-95%) while specificity was high 91% (95%-CI, 82-96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60-98%) and specificity of 84% (95%-CI, 74-90%). In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT.
Serra, Montserrat; Brazís, Pilar; Fondati, Alessandra; Puigdemont, Anna
2006-11-01
To assess binding of IgE to native, whole hydrolyzed, and separated hydrolyzed fractions of soy protein in serum obtained from dogs with experimentally induced soy protein hypersensitivity. 8 naïve Beagles (6 experimentally sensitized to native soy protein and 2 control dogs). 6 dogs were sensitized against soy protein by administration of allergens during a 90-day period. After the sensitization protocol was completed, serum concentrations of soy-specific IgE were measured and intradermal skin tests were performed in all 6 dogs to confirm that the dogs were sensitized against soy protein. Serum samples from each sensitized and control dog underwent western blot analysis to assess the molecular mass band pattern of the different allergenic soy fractions and evaluate reactivities to native and hydrolyzed soy protein. In sera from sensitized dogs, a characteristic band pattern with 2 major bands (approx 75 and 50 kd) and 2 minor bands (approx 31 and 20 kd) was detected, whereas only a diffuse band pattern associated with whole hydrolyzed soy protein was detected in the most reactive dog. Reactivity was evident only for the higher molecular mass peptide fraction. In control dogs, no IgE reaction to native or hydrolyzed soy protein was detected. Data suggest that the binding of soy-specific IgE to the hydrolyzed soy protein used in the study was significantly reduced, compared with binding of soy-specific IgE to the native soy protein, in dogs with experimentally induced soy hypersensitivity.
Optimal Hemoglobin A1c Levels for Screening of Diabetes and Prediabetes in the Japanese Population.
Shimodaira, Masanori; Okaniwa, Shinji; Hanyu, Norinao; Nakayama, Tomohiro
2015-01-01
The aim of this study was to evaluate the utility of hemoglobin A1c (HbA1c) to identify individuals with diabetes and prediabetes in the Japanese population. A total of 1372 individuals without known diabetes were selected for this study. A 75 g oral glucose tolerance test (OGTT) was used to diagnose diabetes and prediabetes. The ability of HbA1c to detect diabetes and prediabetes was investigated using receiver operating characteristic (ROC) analysis. The kappa (κ) coefficient was used to test the agreement between HbA1c categorization and OGTT-based diagnosis. ROC analysis demonstrated that HbA1c was a good test to identify diabetes and prediabetes, with areas under the curve of 0.918 and 0.714, respectively. Optimal HbA1c cutoffs for diagnosing diabetes and prediabetes were 6.0% (sensitivity 83.7%, specificity 87.6%) and 5.7% (sensitivity 60.6%, specificity 72.1%), respectively, although the cutoff for prediabetes showed low accuracy (67.6%) and a high false-negative rate (39.4%). Agreement between HbA1c categorization and OGTT-based diagnosis was low in diabetes (κ = 0.399) and prediabetes (κ = 0.324). In Japanese subjects, the HbA1c cutoff of 6.0% had appropriate sensitivity and specificity for diabetes screening, whereas the cutoff of 5.7% had modest sensitivity and specificity in identifying prediabetes. Thus, HbA1c may be inadequate as a screening tool for prediabetes.
Validation of a single screening question for problem drinking.
Williams, R; Vinson, D C
2001-04-01
The researchers hoped to confirm the sensitivity and specificity of a single screening question for problem drinking: "When was the last time you had more than X drinks in 1 day?", where X=4 for women and X=5 for men. Cross-sectional study. Adult patients presenting to 3 emergency departments in Boone County, Missouri, for care within 48 hours of an injury. The answers to the question were coded as never, more than 12 months ago, 3 to 12 months ago, and within the past 3 months. Problematic drinking was defined as either hazardous drinking (identified by a 29-day retrospective interview) or a past-year alcohol use disorder (defined by questions from the Diagnostic Interview Schedule). There was a 70% participation rate. Of 2517 interviewed patients: 29% were hazardous drinkers; 20% had a past-year alcohol use disorder; and 35% had either or both. Considering "within the last 3 months" as positive, the sensitivity of the single question was 86%, and the specificity was 86%. In men (n=1432), sensitivity and specificity were 88% and 81%; in women, 83% and 91%. Using the 4 answer options for the question, the area under the receiver-operating characteristic curve was 0.90. Controlling for age, sex, tobacco use, injury severity, and breath alcohol level in logistic regression models changed the findings minimally. A single question about the last episode of heavy drinking has clinically useful sensitivity and specificity in detecting hazardous drinking and alcohol use disorders.
Performance characteristics of the ARCHITECT anti-HCV assay.
Jonas, Gesa; Pelzer, Claudia; Beckert, Christian; Hausmann, Michael; Kapprell, Hans-Peter
2005-10-01
The ARCHITECT Anti-HCV assay is a fully automated high throughput chemiluminescent microparticle immunoassay (CMIA) for the detection of antibodies to structural and nonstructural proteins of the hepatitis C virus (HCV). To further enhance the performance of this test, the assay was modified to improve the specificity for blood donor specimens. The specificity of the enhanced ARCHITECT Anti-HCV assay was evaluated by screening blood donor samples randomly collected from various German blood banks, as well as hospitalized patient samples derived from Germany and the US. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels and on a commercially available worldwide anti-HCV genotype performance panel. Apparent specificity of the modified ARCHITECT Anti-HCV assay in a blood donor population consisting of 3811 specimens was 99.92%, compared to 99.76% for the current on-market assay. Additionally, antibody sensitivity was determined on commercially available anti-HCV seroconversion panels. Seroconversion sensitivity equivalent to or better than the current on-market product was observed by testing 33 seroconversion panels. This study demonstrates that the modified version of the ARCHITECT Anti-HCV assay shows improved specificity for blood donor specimens compared to the current assay on market without compromising sensitivity. With the availability of the improved ARCHITECT Anti-HCV assay and the recent launch of the ARCHITECT HIV Ag/Ab Combo assay, the ARCHITECT system now offers a full hepatitis/retrovirus menu with excellent performance on a high throughput, random access, automated analyzer, ideally suited for blood screening and diagnostic applications.
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-01
Purpose To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). Methods 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. Results 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. Conclusions CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR. PMID:28042958
The prevalence of depression and the accuracy of depression screening tools in migraine patients.
Amoozegar, Farnaz; Patten, Scott B; Becker, Werner J; Bulloch, Andrew G M; Fiest, Kirsten M; Davenport, W Jeptha; Carroll, Christopher R; Jette, Nathalie
2017-09-01
Migraine and depression are common comorbid conditions. The purpose of this study was to assess how well the Patient Health Questionnaire (PHQ-9) and the Hospital Anxiety and Depression Scale (HADS) perform as depression screening tools in patients with migraine. Three hundred consecutive migraine patients were recruited from a large headache center. The PHQ-9 and HADS were self-administered and validated against the Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders-IV, a gold standard for the diagnosis of depression. Sensitivity, specificity, positive predictive value, negative predictive value and receiver-operator characteristic curves were calculated for the PHQ-9 and HADS. At the traditional cut-point of 10, the PHQ-9 demonstrated 82.0% sensitivity and 79.9% specificity. At a cut-point of 8, the HADS demonstrated 86.5% sensitivity and specificity. The PHQ-9 algorithm performed poorly (53.8% sensitivity, 94.9% specificity). The point prevalence of depression in this study was 25.0% (95% CI 19.0-31.0), and 17.0% of patients had untreated depression. In this study, the PHQ-9 and HADS performed well in migraine patients attending a headache clinic, but optimal cut-points to screen for depression vary depending on the goals of the assessment. Also, migraine patients attending a headache clinic have a high prevalence of depression and many are inadequately treated. Future studies are needed to confirm these findings and to evaluate the impact of depression screening. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhang, Li; Tang, Min; Min, Zhiqian; Lu, Jun; Lei, Xiaoyan; Zhang, Xiaoling
2016-06-01
Magnetic resonance imaging (MRI) is increasingly being used to examine patients with suspected breast cancer. To determine the diagnostic performance of combined dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and diffusion-weighted imaging (DWI) for breast cancer detection. A comprehensive search of the PUBMED, EMBASE, Web of Science, and Cochrane Library databases was performed up to September 2014. Statistical analysis included pooling of sensitivity and specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and diagnostic accuracy using the summary receiver operating characteristic (SROC). All analyses were conducted using STATA (version 12.0), RevMan (version 5.2), and Meta-Disc 1.4 software programs. Fourteen studies were analyzed, which included a total of 1140 patients with 1276 breast lesions. The pooled sensitivity and specificity of combined DCE-MRI and DWI were 91.6% and 85.5%, respectively. The pooled sensitivity and specificity of DWI-MRI were 86.0% and 75.6%, respectively. The pooled sensitivity and specificity of DCE-MRI were 93.2% and 71.1%. The area under the SROC curve (AUC-SROC) of combined DCE-MRI and DWI was 0.94, the DCE-MRI of 0.85. Deeks testing confirmed no significant publication bias in all studies. Combined DCE-MRI and DWI had superior diagnostic accuracy than either DCE-MRI or DWI alone for the diagnosis of breast cancer. © The Foundation Acta Radiologica 2015.
Poreba, Marcin; Szalek, Aleksandra; Rut, Wioletta; Kasperkiewicz, Paulina; Rutkowska-Wlodarczyk, Izabela; Snipas, Scott J.; Itoh, Yoshifumi; Turk, Dusan; Turk, Boris; Overall, Christopher M.; Kaczmarek, Leszek; Salvesen, Guy S.; Drag, Marcin
2017-01-01
Internally quenched fluorescent (IQF) peptide substrates originating from FRET (Förster Resonance Energy Transfer) are powerful tool for examining the activity and specificity of proteases, and a variety of donor/acceptor pairs are extensively used to design individual substrates and combinatorial libraries. We developed a highly sensitive and adaptable donor/acceptor pair that can be used to investigate the substrate specificity of cysteine proteases, serine proteases and metalloproteinases. This novel pair comprises 7-amino-4-carbamoylmethylcoumarin (ACC) as the fluorophore and 2,4-dinitrophenyl-lysine (Lys(DNP)) as the quencher. Using caspase-3, caspase-7, caspase-8, neutrophil elastase, legumain, and two matrix metalloproteinases (MMP2 and MMP9), we demonstrated that substrates containing ACC/Lys(DNP) exhibit 7 to 10 times higher sensitivity than conventional 7-methoxy-coumarin-4-yl acetic acid (MCA)/Lys(DNP) substrates; thus, substantially lower amounts of substrate and enzyme can be used for each assay. We therefore propose that the ACC/Lys(DNP) pair can be considered a novel and sensitive scaffold for designing substrates for any group of endopeptidases. We further demonstrate that IQF substrates containing unnatural amino acids can be used to investigate protease activities/specificities for peptides containing post-translationally modified amino acids. Finally, we used IQF substrates to re-investigate the P1-Asp characteristic of caspases, thus demonstrating that some human caspases can also hydrolyze substrates after glutamic acid. PMID:28230157
Genetic point-of-care diagnosis of Mycoplasma pneumoniae infection using LAMP assay.
Kakuya, Fujio; Kinebuchi, Takahiro; Fujiyasu, Hiroaki; Tanaka, Ryosuke; Kano, Hiroki
2014-08-01
Mycoplasma pneumoniae (MP) is a major pathogen of lower respiratory tract infection (LRTI) in children. A rapid diagnostic method during the acute phase is required for the prescription of effective antibiotics. A prospective, single-centered study was conducted on community-acquired LRTI in children. We regarded the day of fever onset as the first day of illness. In part 1, we studied 191 patients with signs of LRTI. We compared diagnostic reliability using loop-mediated isothermal amplification (LAMP) assay and serological testing at the first visit. In part 2, we evaluated the clinical characteristics of 117 patients with positive LAMP assay. In part 1, 31 patients met the definite MP infection criteria. LAMP assay had a sensitivity of 96.8% and specificity of 100%, whereas enzyme immunoassay had a sensitivity of 38.7% and specificity of 76.9%, and particle agglutination test had a sensitivity of 19.4% and specificity of 93.1%. In part 2, of 106 patients with fever, 100 patients were diagnosed by the day 7 of illness. The diagnosis was made a mean of 3.5 ± 2.1 days after the onset of fever. LAMP assay had excellent sensitivity and specificity for the detection of acute MP infection at the first visit. This assay can diagnose MP infection during the very acute phase. LAMP assay is appropriate for genetic point-of-care diagnosis of MP infection in hospital laboratories. © 2014 Japan Pediatric Society.
Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S
2016-01-01
Objective: To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. Methods: A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. Results: 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83–0.88] and the specificity was 0.95 (0.93–0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44–0.51) and 0.37 (0.34–0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63–3.19). Conclusion: DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules. PMID:27759428
Petrillo, Antonella; Fusco, Roberta; Petrillo, Mario; Granata, Vincenza; Delrio, Paolo; Bianco, Francesco; Pecori, Biagio; Botti, Gerardo; Tatangelo, Fabiana; Caracò, Corradina; Aloj, Luigi; Avallone, Antonio; Lastoria, Secondo
2017-01-31
To investigate dynamic contrast enhanced-MRI (DCE-MRI) in the preoperative chemo-radiotherapy (CRT) assessment for locally advanced rectal cancer (LARC) compared to18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT). 75 consecutive patients with LARC were enrolled in a prospective study. DCE-MRI analysis was performed measuring SIS: linear combination of percentage change (Δ) of maximum signal difference (MSD) and wash-out slope (WOS). 18F-FDG PET/CT analysis was performed using SUV maximum (SUVmax). Tumor regression grade (TRG) were estimated after surgery. Non-parametric tests, receiver operating characteristic were evaluated. 55 patients (TRG1-2) were classified as responders while 20 subjects as non responders. ΔSIS reached sensitivity of 93%, specificity of 80% and accuracy of 89% (cut-off 6%) to differentiate responders by non responders, sensitivity of 93%, specificity of 69% and accuracy of 79% (cut-off 30%) to identify pathological complete response (pCR). Therapy assessment via ΔSUVmax reached sensitivity of 67%, specificity of 75% and accuracy of 70% (cut-off 60%) to differentiate responders by non responders and sensitivity of 80%, specificity of 31% and accuracy of 51% (cut-off 44%) to identify pCR. CRT response assessment by DCE-MRI analysis shows a higher predictive ability than 18F-FDG PET/CT in LARC patients allowing to better discriminate significant and pCR.
Pinelli, Nicole R; Jantz, Arin S; Martin, Emily T; Jaber, Linda A
2011-10-01
Glycated hemoglobin (A1C) has been recommended by the American Diabetes Association for the diagnosis of diabetes and prediabetes. The diagnostic utility of A1C has not been evaluated in Arabs, a population at increased risk for developing diabetes. Our objective was to examine the sensitivity and specificity of A1C for the diagnosis of diabetes and prediabetes in Arabs. In this cross-sectional study, glucose tolerance was classified by the American Diabetes Association diagnostic criteria specified for A1C, fasting plasma glucose, and 75-g oral glucose tolerance test. A population-based representative sample of 482 randomly selected adult Arabs without known diabetes was studied. Sensitivity, specificity, and area under the receiver operating characteristic curve of A1C diagnostic cutpoints for diabetes and prediabetes were calculated. κ Coefficients were used to test for agreement between A1C categorization and glucose-based diagnoses. A1C testing correctly identified 5% of individuals diagnosed with diabetes by oral glucose tolerance test, 13% by fasting plasma glucose, and 41% by both criteria. A1C alone identified 14% of individuals diagnosed with impaired glucose tolerance, 9% with impaired fasting glucose, and 33% with both abnormalities. Sensitivity, specificity, and area under the receiver operating characteristic curve were 19% (16-23%), 100% (99-100%), and 77% (69-85%) for diabetes A1C cutpoint and 14% (11-17%), 91% (89-94%), and 57% (52-62%) for prediabetes A1C range. A1C cutpoint of 6.2% for diabetes and 5.1% for prediabetes yielded the highest accuracy but still missed 73% of those with diabetes and 31% with prediabetes. Agreement between A1C and diabetes (κ = 0.2835) or prediabetes (κ = 0.0530) was low. A1C-based criteria yield a high proportion of false-negative tests for diabetes and prediabetes in Arabs. Racial/ethnic differences in A1C performance for diagnosis and prediction of diabetes exist. This paper examines its utility against glucose measurements in an at-risk Arab population.
Quantifying the effect of side branches in endothelial shear stress estimates
Giannopoulos, Andreas A.; Chatzizisis, Yiannis S.; Maurovich-Horvat, Pal; Antoniadis, Antonios P.; Hoffmann, Udo; Steigner, Michael L.; Rybicki, Frank J.; Mitsouras, Dimitrios
2016-01-01
Background and aims Low and high endothelial shear stress (ESS) is associated with coronary atherosclerosis progression and high-risk plaque features. Coronary ESS is currently assessed via computational fluid dynamic (CFD) simulation in the lumen geometry determined from invasive imaging such as intravascular ultrasound and optical coherence tomography. This process typically omits side branches of the target vessel in the CFD model as invasive imaging of those vessels is not clinically-indicated. The purpose of this study was to determine the extent to which this simplification affects the determination of those regions of the coronary endothelium subjected to pathologic ESS. Methods We determined the diagnostic accuracy of ESS profiling without side branches to detect pathologic ESS in the major coronary arteries of 5 hearts imaged ex vivo with CT angiography. ESS of the three major coronary arteries was calculated both without (test model), and with (reference model) inclusion of all side branches >1.5 mm in diameter, using previously-validated CFD approaches. Diagnostic test characteristics (accuracy, sensitivity, specificity and negative and positive predictive value [NPV/PPV]) with respect to the reference model were assessed for both the entire length as well as only the proximal portion of each major coronary artery, where the majority of high-risk plaques occur. Results Using the model without side branches overall accuracy, sensitivity, specificity, NPV and PPV were 83.4%, 54.0%, 96%, 95.9% and 55.1%, respectively to detect low ESS, and 87.0%, 67.7%, 90.7%, 93.7% and 57.5%, respectively to detect high ESS. When considering only the proximal arteries, test characteristics differed for low and high ESS, with low sensitivity (67.7%) and high specificity (90.7%) to detect low ESS, and low sensitivity (44.7%) and high specificity (95.5%) to detect high ESS. Conclusions The exclusion of side branches in ESS vascular profiling studies greatly reduces the ability to detect regions of the major coronary arteries subjected to pathologic ESS. Single-conduit models can in general only be used to rule out pathologic ESS. PMID:27372207
Quantifying the effect of side branches in endothelial shear stress estimates.
Giannopoulos, Andreas A; Chatzizisis, Yiannis S; Maurovich-Horvat, Pal; Antoniadis, Antonios P; Hoffmann, Udo; Steigner, Michael L; Rybicki, Frank J; Mitsouras, Dimitrios
2016-08-01
Low and high endothelial shear stress (ESS) is associated with coronary atherosclerosis progression and high-risk plaque features. Coronary ESS is currently assessed via computational fluid dynamic (CFD) simulation of coronary blood flow in the lumen geometry determined from invasive imaging such as intravascular ultrasound and optical coherence tomography. This process typically omits side branches of the target vessel in the CFD model as invasive imaging of those vessels is not usually clinically-indicated. The purpose of this study was to determine the extent to which this simplification affects the determination of those regions of the coronary endothelium subjected to pathologic ESS. We determined the diagnostic accuracy of ESS profiling without side branches to detect pathologic ESS in the major coronary arteries of 5 hearts imaged ex vivo with computed tomography angiography (CTA). ESS of the three major coronary arteries was calculated both without (test model), and with (reference model) inclusion of all side branches >1.5 mm in diameter, using previously-validated CFD approaches. Diagnostic test characteristics (accuracy, sensitivity, specificity and negative and positive predictive value [NPV/PPV]) with respect to the reference model were assessed for both the entire length as well as only the proximal portion of each major coronary artery, where the majority of high-risk plaques occur. Using the model without side branches overall accuracy, sensitivity, specificity, NPV and PPV were 83.4%, 54.0%, 96%, 95.9% and 55.1%, respectively to detect low ESS, and 87.0%, 67.7%, 90.7%, 93.7% and 57.5%, respectively to detect high ESS. When considering only the proximal arteries, test characteristics differed for low and high ESS, with low sensitivity (67.7%) and high specificity (90.7%) to detect low ESS, and low sensitivity (44.7%) and high specificity (95.5%) to detect high ESS. The exclusion of side branches in ESS vascular profiling studies greatly reduces the ability to detect regions of the major coronary arteries subjected to pathologic ESS. Single-conduit models can in general only be used to rule out pathologic ESS. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Postel, A; Ziller, M; Rudolf, M; Letzel, T; Ehricht, Ralf; Pourquier, P; Dauber, M; Grund, C; Beer, Martin; Harder, T C
2011-04-01
Avian influenza viruses (AIVs) of the H5 and H7 subtypes can cause substantial economic losses in the poultry industry and are a potential threat to public health. Serosurveillance of poultry populations is an important monitoring tool and can also be used for control of vaccination campaigns. The purpose of this study was to develop broadly reactive, yet subtype-specific competitive ELISAs (cELISAs) for the specific detection of antibodies to the notifiable AIV subtypes H5 and H7 as an alternative to the gold standard haemagglutination inhibition assay (HI). Broadly reacting monoclonal competitor antibodies (mAbs) and genetically engineered subtype H5 or H7 haemagglutinin antigen, expressed and in vivo biotinylated in insect cells, were used to develop the cELISAs. Sera from galliform species and water fowl (n=793) were used to evaluate the performance characteristics of the cELISAs. For the H5 specific cELISA, 98.1% test sensitivity and 91.5% test specificity (97.7% and 90.2% for galliforms; 98.9% and 92.6% for waterfowl), and for the H7 cELISA 97.3% sensitivity and 91.8% specificity (95.3% and 98.9% for galliforms; 100% and 82.7% for waterfowl) were reached when compared to HI. The use of competitor mAbs with broad spectrum reactivity within an AIV haemagglutinin subtype allowed for homogenous detection with high sensitivity of subtype-specific antibodies induced by antigenically widely distinct isolates including antigenic drift variants. However, a trade-off regarding sensitivity versus nonspecific detection of interfering antibodies induced by phylo- and antigenically closely related subtypes, e.g., H5 versus H2 and H7 versus H15, must be considered. The observed intersubtype antibody cross-reactivity remains a disturbance variable in AIV subtype-specific serodiagnosis which negatively affects specificity. Copyright © 2011 Elsevier B.V. All rights reserved.
Gas stream analysis using voltage-current time differential operation of electrochemical sensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woo, Leta Yar-Li; Glass, Robert Scott; Fitzpatrick, Joseph Jay
A method for analysis of a gas stream. The method includes identifying an affected region of an affected waveform signal corresponding to at least one characteristic of the gas stream. The method also includes calculating a voltage-current time differential between the affected region of the affected waveform signal and a corresponding region of an original waveform signal. The affected region and the corresponding region of the waveform signals have a sensitivity specific to the at least one characteristic of the gas stream. The method also includes generating a value for the at least one characteristic of the gas stream basedmore » on the calculated voltage-current time differential.« less
Fornarino, Stefania; Rossi, Daniela Paola; Severino, Mariasavina; Pistorio, Angela; Allegri, Anna Elsa Maria; Martelli, Simona; Doria Lamba, Laura; Lanteri, Paola
2017-02-01
To evaluate the contribution of somatosensory evoked potentials after median nerve (MN-SEPs) and posterior tibial nerve (PTN-SEPs) stimulation in functional assessment of cervical and lumbar spinal stenosis in children with achondroplasia. We reviewed MN-SEPs, PTN-SEPs, and spinal magnetic resonance imaging (MRI) examinations performed in 58 patients with achondroplasia (25 males, 33 females; age range 21d-16y 10mo; mean age 4y 3mo [SD 4y 1mo]). Patients were subdivided into four age categories: <2 years, between 2 to 4 years, between 4 to 8 years, and ≥8 years. The peak latency of P37 for PTN-SEPs, the peak latencies of N11, N13, P14, and N20, and the N13-N20 interpeak latency (IPL) for MN-SEPs were collected; the diagnostic accuracy measures of these parameters (analysis of receiver operating characteristic [ROC] curves) with respect to the presence of foramen magnum or lumbar spinal stenosis were analysed in each age category. The ROC curve analysis showed that the most sensitive parameter in detecting the presence of foramen magnum stenosis was P37 latency in the first two age categories (<2y and ≥2-4y; sensitivity 0.63, specificity 1.00, and sensitivity 1.00, specificity 0.75 respectively). In the third age category (≥4-8y), the most sensitive parameter in detecting the presence of foramen magnum stenosis was IPLs N13-N20 (sensitivity 0.73, specificity 0.87), whereas in the last age category (≥8y), the most important parameter was N20 latency (sensitivity 0.75, specificity 0.77). In children with achondroplasia, the cortical component of PTN-SEPs is more sensitive than the cortical component and central conduction time of MN-SEPs in detection of cervical spinal cord compression at early ages. © 2016 Mac Keith Press.
Sheppard, James P.; Holder, Roger; Nichols, Linda; Bray, Emma; Hobbs, F.D. Richard; Mant, Jonathan; Little, Paul; Williams, Bryan; Greenfield, Sheila; McManus, Richard J.
2014-01-01
Objectives: Identification of people with lower (white-coat effect) or higher (masked effect) blood pressure at home compared to the clinic usually requires ambulatory or home monitoring. This study assessed whether changes in SBP with repeated measurement at a single clinic predict subsequent differences between clinic and home measurements. Methods: This study used an observational cohort design and included 220 individuals aged 35–84 years, receiving treatment for hypertension, but whose SBP was not controlled. The characteristics of change in SBP over six clinic readings were defined as the SBP drop, the slope and the quadratic coefficient using polynomial regression modelling. The predictive abilities of these characteristics for lower or higher home SBP readings were investigated with logistic regression and repeated operating characteristic analysis. Results: The single clinic SBP drop was predictive of the white-coat effect with a sensitivity of 90%, specificity of 50%, positive predictive value of 56% and negative predictive value of 88%. Predictive values for the masked effect and those of the slope and quadratic coefficient were slightly lower, but when the slope and quadratic variables were combined, the sensitivity, specificity, positive and negative predictive values for the masked effect were improved to 91, 48, 24 and 97%, respectively. Conclusion: Characteristics obtainable from multiple SBP measurements in a single clinic in patients with treated hypertension appear to reasonably predict those unlikely to have a large white-coat or masked effect, potentially allowing better targeting of out-of-office monitoring in routine clinical practice. PMID:25144295
Effects of noise upon human information processing
NASA Technical Reports Server (NTRS)
Cohen, H. H.; Conrad, D. W.; Obrien, J. F.; Pearson, R. G.
1974-01-01
Studies of noise effects upon human information processing are described which investigated whether or not effects of noise upon performance are dependent upon specific characteristics of noise stimulation and their interaction with task conditions. The difficulty of predicting noise effects was emphasized. Arousal theory was considered to have explanatory value in interpreting the findings of all the studies. Performance under noise was found to involve a psychophysiological cost, measured by vasoconstriction response, with the degree of response cost being related to scores on a noise annoyance sensitivity scale. Noise sensitive subjects showed a greater autonomic response under noise stimulation.
Kostera, Joshua; Leckie, Gregor; Tang, Ning; Lampinen, John; Szostak, Magdalena; Abravaya, Klara; Wang, Hong
2016-12-01
Clinical management of drug-resistant tuberculosis patients continues to present significant challenges to global health. To tackle these challenges, the Abbott RealTime MTB RIF/INH Resistance assay was developed to accelerate the diagnosis of rifampicin and/or isoniazid resistant tuberculosis to within a day. This article summarizes the performance of the Abbott RealTime MTB RIF/INH Resistance assay; including reliability, analytical sensitivity, and clinical sensitivity/specificity as compared to Cepheid GeneXpert MTB/RIF version 1.0 and Hain MTBDRplus version 2.0. The limit of detection (LOD) of the Abbott RealTime MTB RIF/INH Resistance assay was determined to be 32 colony forming units/milliliter (cfu/mL) using the Mycobacterium tuberculosis (MTB) strain H37Rv cell line. For rifampicin resistance detection, the Abbott RealTime MTB RIF/INH Resistance assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Cepheid GeneXpert MTB/RIF. For isoniazid resistance detection, the assay demonstrated statistically equivalent clinical sensitivity and specificity as compared to Hain MTBDRplus. The performance data presented herein demonstrate that the Abbott RealTime MTB RIF/INH Resistance assay is a sensitive, robust, and reliable test for realtime simultaneous detection of first line anti-tuberculosis antibiotics rifampicin and isoniazid in patient specimens. Copyright © 2016 The Author. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Kobayashi, Hisataka; Hama, Yukihiro; Koyama, Yoshinori; Barrett, Tristan; Urano, Yasuteru; Choyke, Peter L.
2007-02-01
Target-specific contrast agents are being developed for the molecular imaging of cancer. Optically detectable target-specific agents are promising for clinical applications because of their high sensitivity and specificity. Pre clinical testing is needed, however, to validate the actual sensitivity and specificity of these agents in animal models, and involves both conventional histology and immunohistochemistry, which requires large numbers of animals and samples with costly handling. However, a superior validation tool takes advantage of genetic engineering technology whereby cell lines are transfected with genes that induce the target cell to produce fluorescent proteins with characteristic emission spectra thus, identifying them as cancer cells. Multicolor fluorescence imaging of these genetically engineered probes can provide rapid validation of newly developed exogenous probes that fluoresce at different wavelengths. For example, the plasmid containing the gene encoding red fluorescent protein (RFP) was transfected into cell lines previously developed to either express or not-express specific cell surface receptors. Various antibody-based or receptor ligand-based optical contrast agents with either green or near infrared fluorophores were developed to concurrently target and validate cancer cells and their positive and negative controls, such as β-D-galactose receptor, HER1 and HER2 in a single animal/organ. Spectrally resolved fluorescence multicolor imaging was used to detect separate fluorescent emission spectra from the exogenous agents and RFP. Therefore, using this in vivo imaging technique, we were able to demonstrate the sensitivity and specificity of the target-specific optical contrast agents, thus reducing the number of animals needed to conduct these experiments.
Nonlinear vibrations analysis of rotating drum-disk coupling structure
NASA Astrophysics Data System (ADS)
Chaofeng, Li; Boqing, Miao; Qiansheng, Tang; Chenyang, Xi; Bangchun, Wen
2018-04-01
A dynamic model of a coupled rotating drum-disk system with elastic support is developed in this paper. By considering the effects of centrifugal and Coriolis forces as well as rotation-induced hoop stress, the governing differential equation of the drum-disk is derived by Donnell's shell theory. The nonlinear amplitude-frequency characteristics of coupled structure are studied. The results indicate that the natural characteristics of the coupling structure are sensitive to the supporting stiffness of the disk, and the sensitive range is affected by rotating speeds. The circumferential wave numbers can affect the characteristics of the drum-disk structure. If the circumferential wave number n = 1 , the vibration response of the drum keeps a stable value under an unbalanced load of the disk, there is no coupling effect if n ≠ 1 . Under the excitation, the nonlinear hardening characteristics of the forward traveling wave are more evident than that of the backward traveling wave. Moreover, because of the coupling effect of the drum and the disk, the supporting stiffness of the disk has certain effect on the nonlinear characteristics of the forward and backward traveling waves. In addition, small length-radius and thickness-radius ratios have a significant effect on the nonlinear characteristics of the coupled structure, which means nonlinear shell theory should be adopted to design rotating drum's parameter for its specific structural parameters.
Mansouri, Sheila; Singh, Sanjay; Alamsahebpour, Amir; Burrell, Kelly; Li, Mira; Karabork, Merve; Ekinci, Can; Koch, Elizabeth; Solaroglu, Ihsan; Chang, Jeffery T; Wouters, Bradly; Aldape, Kenneth; Zadeh, Gelareh
2016-08-30
The RNAse III endonuclease DICER is a key regulator of microRNA (miRNA) biogenesis and is frequently decreased in a variety of malignancies. We characterized the role of DICER in glioblastoma (GB), specifically demonstrating its effects on the ability of glioma stem-like cells (GSCs) to form tumors in a mouse model of GB. DICER silencing in GSCs reduced their stem cell characteristics, while tumors arising from these cells were more aggressive, larger in volume, and displayed a higher proliferation index and lineage differentiation. The resulting tumors, however, were more sensitive to radiation treatment. Our results demonstrate that DICER silencing enhances the tumorigenic potential of GSCs, providing a platform for analysis of specific relevant miRNAs and development of potentially novel therapies against GB.
Digital lock-in detection of site-specific magnetism in magnetic materials
Haskel, Daniel [Naperville, IL; Lang, Jonathan C [Naperville, IL; Srajer, George [Oak Park, IL
2008-07-22
The polarization and diffraction characteristics of x-rays incident upon a magnetic material are manipulated to provide a desired magnetic sensitivity in the material. The contrast in diffracted intensity of opposite helicities of circularly polarized x-rays is measured to permit separation of magnetic signals by element type and by atomic environment. This allows for the direct probing of magnetic signals from elements of the same species in nonequivalent atomic environments to better understand the behavior and characteristics of permanent magnetic materials. By using known crystallographic information together with manipulation of the polarization of x-rays having energies tuned near element-specific electronic excitations and by detecting and comparing the incident and diffracted photons at the same frequency, more accurate magnetic measurements can be made over shorter observation periods.
Dastych, Milan; Dastych, Milan; Novotná, Hana; Cíhalová, J
2008-10-01
The purpose of this study was to investigate and compare the specificity, sensitivity, and area under curve (AUC) of the lactulose/mannitol ratio, lactulose/creatinine ratio, and lactulose recovery and their diagnostic value for intestinal permeability assessment within the absorption lactulose/mannitol (L/M) test. The value of the lactulose/mannitol ratio, lactulose/creatinine ratio, and the percentage of lactulose recovery in Crohn's disease (0.0763 +/- 0.0369; 99.62 +/- 67.87; 1.0478 +/- 0.6148) and in liver cirrhosis (0.0517 +/- 0.0365; 54.65 +/- 53.26; 0.838 +/- 0.929) were significantly different from the values measured in the control group (0.0123 +/- 0.0081; 10.95 +/- 7.07; 0.2438 +/- 0.1568), P < 0.0001-0.002). In Crohn's disease, specificity, sensitivity, and AUC were 100%, 89.5%, and 0.987, respectively, of the lactulose/mannitol ratio at a cut-off level of 0.022. In liver cirrhosis, the test characteristics were 88.5%, 84.2%, and 0.910 at a cut-off level of 0.018. The lactulose/mannitol ratio was evaluated to have the highest diagnostic value to assess intestinal permeability.
Huber, J; Hüsler, J; Dieppe, P; Günther, K P; Dreinhöfer, K; Judge, A
2016-03-01
To validate a new method to identify responders (relative effect per patient (REPP) >0.2) using the OMERACT-OARSI criteria as gold standard in a large multicentre sample. The REPP ([score before - after treatment]/score before treatment) was calculated for 845 patients of a large multicenter European cohort study for THR. The patients with a REPP >0.2 were defined as responders. The responder rate was compared to the gold standard (OMERACT-OARSI criteria) using receiver operator characteristic (ROC) curve analysis for sensitivity, specificity and percentage of appropriately classified patients. With the criterion REPP>0.2 85.4% of the patients were classified as responders, applying the OARSI-OMERACT criteria 85.7%. The new method had 98.8% sensitivity, 94.2% specificity and 98.1% of the patients were correctly classified compared to the gold standard. The external validation showed a high sensitivity and also specificity of a new criterion to identify a responder compared to the gold standard method. It is simple and has no uncertainties due to a single classification criterion. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Field validation of recombinant antigen immunoassays for diagnosis of Lassa fever.
Boisen, Matthew L; Hartnett, Jessica N; Shaffer, Jeffrey G; Goba, Augustine; Momoh, Mambu; Sandi, John Demby; Fullah, Mohamed; Nelson, Diana K S; Bush, Duane J; Rowland, Megan M; Heinrich, Megan L; Koval, Anatoliy P; Cross, Robert W; Barnes, Kayla G; Lachenauer, Anna E; Lin, Aaron E; Nekoui, Mahan; Kotliar, Dylan; Winnicki, Sarah M; Siddle, Katherine J; Gbakie, Michael; Fonnie, Mbalu; Koroma, Veronica J; Kanneh, Lansana; Kulakosky, Peter C; Hastie, Kathryn M; Wilson, Russell B; Andersen, Kristian G; Folarin, Onikepe O; Happi, Christian T; Sabeti, Pardis C; Geisbert, Thomas W; Saphire, Erica Ollmann; Khan, S Humarr; Grant, Donald S; Schieffelin, John S; Branco, Luis M; Garry, Robert F
2018-04-12
Lassa fever, a hemorrhagic fever caused by Lassa virus (LASV), is endemic in West Africa. It is difficult to distinguish febrile illnesses that are common in West Africa from Lassa fever based solely on a patient's clinical presentation. The field performance of recombinant antigen-based Lassa fever immunoassays was compared to that of quantitative polymerase chain assays (qPCRs) using samples from subjects meeting the case definition of Lassa fever presenting to Kenema Government Hospital in Sierra Leone. The recombinant Lassa virus (ReLASV) enzyme-linked immunosorbant assay (ELISA) for detection of viral antigen in blood performed with 95% sensitivity and 97% specificity using a diagnostic standard that combined results of the immunoassays and qPCR. The ReLASV rapid diagnostic test (RDT), a lateral flow immunoassay based on paired monoclonal antibodies to the Josiah strain of LASV (lineage IV), performed with 90% sensitivity and 100% specificity. ReLASV immunoassays performed better than the most robust qPCR currently available, which had 82% sensitivity and 95% specificity. The performance characteristics of recombinant antigen-based Lassa virus immunoassays indicate that they can aid in the diagnosis of LASV Infection and inform the clinical management of Lassa fever patients.
Hoyer, Annika; Kuss, Oliver
2018-05-01
Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.
Cho, Pyo Yun; Na, Byoung-Kuk; Mi Choi, Kyung; Kim, Jin Su; Cho, Shin-Hyeong; Lee, Won-Ja; Lim, Sung-Bin; Cha, Seok Ho; Park, Yun-Kyu; Pak, Jhang Ho; Lee, Hyeong-Woo; Hong, Sung-Jong; Kim, Tong-Soo
2013-01-01
Microscopic examination of eggs of parasitic helminths in stool samples has been the most widely used classical diagnostic method for infections, but tiny and low numbers of eggs in stool samples often hamper diagnosis of helminthic infections with classical microscopic examination. Moreover, it is also difficult to differentiate parasite eggs by the classical method, if they have similar morphological characteristics. In this study, we developed a rapid and sensitive polymerase chain reaction (PCR)-based molecular diagnostic method for detection of Clonorchis sinensis eggs in stool samples. Nine primers were designed based on the long-terminal repeat (LTR) of C. sinensis retrotransposon1 (CsRn1) gene, and seven PCR primer sets were paired. Polymerase chain reaction with each primer pair produced specific amplicons for C. sinensis, but not for other trematodes including Metagonimus yokogawai and Paragonimus westermani. Particularly, three primer sets were able to detect 10 C. sinensis eggs and were applicable to amplify specific amplicons from DNA samples purified from stool of C. sinensis-infected patients. This PCR method could be useful for diagnosis of C. sinensis infections in human stool samples with a high level of specificity and sensitivity. PMID:23916334
[Skin prick testing versus immumofluorescence testing for mites allergens].
Zhang, Yong; Wang, Zhiyi; Chen, Wei; Ji, Junfeng; Wang, Tianyou; Wang, Qiuping; Li, Zeqing
2012-03-01
To discuss the characteristics of skin prick test (SPT) and immumofluorescence method (IFM) in detecting the atopy of dermatophagoides pteronyssinus (Dp) and dermatophagoides farinae (Df)and explore the relationship of them. Four hundred and ninety-one patients with two or more symptoms of nasal obstruction,itching, sneezing and rhinorrhea received SPT and serum specific IgE detection using IFM. SPT was more sensitive than IFM in detecting the atopy of Dp and Df (P < 0.05). If using the IFM as the gold standard, the sensitivity of SPT was all above 95% with the specificity a little bit lower than 80%. These two methods had a positive correlation in detecting the atopy of Dp and Df (r = 0.779, 0.776; P < 0.01). The sIgE concentrations of these two mites were highly correlated with each other (r = 0.954, P < 0.01), the SPT was highly correlated with each other (r = 0. 946, P < 0.01). SPT was more sensitive than IFM in detecting the atopy of Dp and Df. In most cases, SPT can replace IFM to detect patients' allergia on mites. Besides, it is good enough to detect either of the serum specific IgE concentrations of Dp and Df.
Müller, Matthias J; Müller, Kay-Maria; Fellgiebel, Andreas
2006-05-01
To compare the psychometric properties of the Calgary Depression Rating Scale (CDRS) and the Hamilton Depression Rating Scale (HDRS) for severity assessment of depression in acute schizophrenia. During clinical routine treatment, we investigated 119 inpatients with acute schizophrenia, using the CDRS, the HDRS, and a global 4-point Depression Severity Scale (DEP-SEV). We compared CDRS and HDRS sum scores regarding their diagnostic accuracy, with global severity of depression as the criterion. We estimated sensitivity and specificity on the basis of receiver operating characteristic curves. According to global clinical ratings (DEP-SEV), 31% of patients had no depression, 19% had mild, 31% had moderate, and 19% had severe depression. Sensitivity was significantly higher (P < 0.05) for the CDRS than for the HDRS to assess mild (0.94 vs 0.76, cut-off 3 vs 10 points) or severe depression (1.00 vs 0.78, cut-off 11 vs 22 points); specificity was comparably high (> or = 0.88) for both scales. Despite the fact that both scales were effective in separating mild, moderate, and severe depression, significant advantages emerged for the CDRS to detect mild or severe depression in schizophrenia.
Identification of the need for home visiting nurse: development of a new assessment tool.
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization.
Spatial characteristics of early successional habitat across the Upper Great Lakes states
Brian G. Tavernia; Mark D. Nelson; James D. Garner; Charles H. (Hobie) Perry
2016-01-01
Creation and management of early successional forest (ESF) is needed to halt and reverse declines of bird species dependent on pioneering plant species or young forests. ESF-dependent bird species require specific structural forest classes and are sensitive to forest age (a surrogate for forest structure), patch size, proximity to patch edges, and the juxtaposition of...
ERIC Educational Resources Information Center
Patton, Michael Quinn
2016-01-01
Fidelity concerns the extent to which a specific evaluation sufficiently incorporates the core characteristics of the overall approach to justify labeling that evaluation by its designated name. Fidelity has traditionally meant implementing a model in exactly the same way each time following the prescribed steps and procedures. The essential…
ERIC Educational Resources Information Center
Hannes, Karin; Petry, Katja; Heyvaert, Mieke
2018-01-01
The present article focuses on the meta-aggregative approach to qualitative evidence synthesis. Originally developed in Australia by the Joanna Briggs Institute, it mirrors the review process for reviews of effectiveness outlined by the international Cochrane and Campbell Collaboration, while remaining sensitive to the specific characteristics of…
As part of a study to develop and test a framework for predicting sensitivity of watersheds to land-use activities, temperatures were monitored in 48 second- and third- order streams on the north and south shores of western Lake Superior. Maximun 21-day average temperatures, whic...
Buck Louis, Germaine M; Druschel, Charlotte; Bell, Erin; Stern, Judy E; Luke, Barbara; McLain, Alexander; Sundaram, Rajeshwari; Yeung, Edwina
2015-06-01
To assess the validity of maternally reported assisted reproductive technologies (ART) use and to identify predictors of reporting errors. Linkage study. Not applicable. A total of 5,034 (27%) mothers enrolled, from whom 4,886 (97%) self-reported information about use of infertility treatment, including ART, for the index birth. None. Four measures of validity (sensitivity, specificity, positive and negative predictive values) and use of net reclassification improvement (NRI) methods to identify predictors associated with concordant/discordant maternal reporting. The Upstate New York Infant Development Screening Program (Update KIDS Study) was linked with the Society for Assisted Reproductive Technology Clinic Outcome Reporting System (SART CORS) using a defined algorithm for 2008-2010. The sensitivity, specificity, positive and negative predictive values were high (0.93, 0.99, 0.80, and 1.00, respectively). The validity of maternal report was high, reflecting few differences by participant characteristics except for maternal age dichotomized at 29 years as identified with NRI methods. Maternally reported ART is valid, with little variation across various characteristics. No strong predictors of discordant reporting were found, supporting the utility of population-based research with SART CORS linkage. Published by Elsevier Inc.
Evidence for asexual genetic recombination in sunflower downy mildew, Plasmopara halstedii.
Spring, Otmar; Zipper, Reinhard
2006-06-01
Field isolates and single sporangium lines of the biotrophic Oomycete Plasmopara halstedii, differing in host preference and fungicide sensitivity, were used simultaneously for infection of sunflower. Dual infections led to asexually formed zoosporangia which gave rise to a new phenotype combining the characteristics of the parental strains. The new phenotype showed the metalaxyl-tolerance of one parent and virulence behaviour characteristic of the other, thus being able to infect a specific and fungicide treated sunflower line that neither of the parental strains could infect alone. These characteristics were inherited over many generations and did not occur spontaneously when parental strains were propagated separately. DNA fingerprints with minisatellite and simple sequence repeat primers showed characteristic differences between the patterns of the parental strains and the new phenotype. PCR experiments with mixed parental DNA resulted in additive patterns, but did not show the amplification product specific for the new phenotype. Since sexual reproduction was excluded under the experimental conditions used, the results provide evidence for genetic recombination through parasexual events in dual infections of sunflower downy mildew.
Definition of Forces on Turbomachinery Rotors. Task B Report: Dynamic Analysis of Rotors
NASA Technical Reports Server (NTRS)
Childs, D. W.
1983-01-01
The rotordynamic characteristics of turbomachinery are known to depend on the forces developed due to relative motion between the rotor and the housing. For example, the critical speed locations generally depend on the bearing stiffnesses, seal dampling influences rotor stability and bearing reaction amplitudes near critical speeds, etc. A systematic examination of the influence of changes in the forces acting on rotors is studied. More specifically, the sensitivity of the rotordynamic characteristics to changes in rotor forces is analyzed. Rotordynamic characteristics of the HPOTP (High Pressure Oxygen Turbopump) and HPFTP (High Pressure Fuel Turbopump) of the SSME (Space Shuttle Main Engine) are investigated. Because of their markedly different rotordynamic characteristics, these units are considered to be representative of a range of possible future liquid rocket engine turbomachinery.
Wang, Lina; Li, Hao; Yang, Zhongyuan; Guo, Zhuming; Zhang, Quan
2015-07-01
This study was designed to assess the efficiency of the serum thyrotropin to thyroglobulin ratio for thyroid nodule evaluation in euthyroid patients. Cross-sectional study. Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China. Retrospective analysis was performed for 400 previously untreated cases presenting with thyroid nodules. Thyroid function was tested with commercially available radioimmunoassays. The receiver operating characteristic curves were constructed to determine cutoff values. The efficacy of the thyrotropin:thyroglobulin ratio and thyroid-stimulating hormone for thyroid nodule evaluation was evaluated in terms of sensitivity, specificity, positive predictive value, positive likelihood ratio, negative likelihood ratio, and odds ratio. In receiver operating characteristic curve analysis, the area under the curve was 0.746 for the thyrotropin:thyroglobulin ratio and 0.659 for thyroid-stimulating hormone. With a cutoff point value of 24.97 IU/g for the thyrotropin:thyroglobulin ratio, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 78.9%, 60.8%, 75.5%, 2.01, and 0.35, respectively. The odds ratio for the thyrotropin:thyroglobulin ratio indicating malignancy was 5.80. With a cutoff point value of 1.525 µIU/mL for thyroid-stimulating hormone, the sensitivity, specificity, positive predictive value, positive likelihood ratio, and negative likelihood ratio were 74.0%, 53.2%, 70.8%, 1.58, and 0.49, respectively. The odds ratio indicating malignancy for thyroid-stimulating hormone was 3.23. Increasing preoperative serum thyrotropin:thyroglobulin ratio is a risk factor for thyroid carcinoma, and the correlation of the thyrotropin:thyroglobulin ratio to malignancy is higher than that for serum thyroid-stimulating hormone. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.
Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo
2017-03-01
The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.
Brusselaers, Nele; Labeau, Sonia; Vogelaers, Dirk; Blot, Stijn
2013-03-01
In ventilator-associated pneumonia (VAP), early appropriate antimicrobial therapy may be hampered by involvement of multidrug-resistant (MDR) pathogens. A systematic review and diagnostic test accuracy meta-analysis were performed to analyse whether lower respiratory tract surveillance cultures accurately predict the causative pathogens of subsequent VAP in adult patients. Selection and assessment of eligibility were performed by three investigators by mutual consideration. Of the 525 studies retrieved, 14 were eligible for inclusion (all in English; published since 1994), accounting for 791 VAP episodes. The following data were collected: study and population characteristics; in- and exclusion criteria; diagnostic criteria for VAP; microbiological workup of surveillance and diagnostic VAP cultures. Sub-analyses were conducted for VAP caused by Staphylococcus aureus, Pseudomonas spp., and Acinetobacter spp., MDR microorganisms, frequency of sampling, and consideration of all versus the most recent surveillance cultures. The meta-analysis showed a high accuracy of surveillance cultures, with pooled sensitivities up to 0.75 and specificities up to 0.92 in culture-positive VAP. The area under the curve (AUC) of the hierarchical summary receiver-operating characteristic curve demonstrates moderate accuracy (AUC: 0.90) in predicting multidrug resistance. A sampling frequency of >2/week (sensitivity 0.79; specificity 0.96) and consideration of only the most recent surveillance culture (sensitivity 0.78; specificity 0.96) are associated with a higher accuracy of prediction. This study provides evidence for the benefit of surveillance cultures in predicting MDR bacterial pathogens in VAP. However, clinical and statistical heterogeneity, limited samples sizes, and bias remain important limitations of this meta-analysis.
Predicting distant failure in early stage NSCLC treated with SBRT using clinical parameters.
Zhou, Zhiguo; Folkert, Michael; Cannon, Nathan; Iyengar, Puneeth; Westover, Kenneth; Zhang, Yuanyuan; Choy, Hak; Timmerman, Robert; Yan, Jingsheng; Xie, Xian-J; Jiang, Steve; Wang, Jing
2016-06-01
The aim of this study is to predict early distant failure in early stage non-small cell lung cancer (NSCLC) treated with stereotactic body radiation therapy (SBRT) using clinical parameters by machine learning algorithms. The dataset used in this work includes 81 early stage NSCLC patients with at least 6months of follow-up who underwent SBRT between 2006 and 2012 at a single institution. The clinical parameters (n=18) for each patient include demographic parameters, tumor characteristics, treatment fraction schemes, and pretreatment medications. Three predictive models were constructed based on different machine learning algorithms: (1) artificial neural network (ANN), (2) logistic regression (LR) and (3) support vector machine (SVM). Furthermore, to select an optimal clinical parameter set for the model construction, three strategies were adopted: (1) clonal selection algorithm (CSA) based selection strategy; (2) sequential forward selection (SFS) method; and (3) statistical analysis (SA) based strategy. 5-cross-validation is used to validate the performance of each predictive model. The accuracy was assessed by area under the receiver operating characteristic (ROC) curve (AUC), sensitivity and specificity of the system was also evaluated. The AUCs for ANN, LR and SVM were 0.75, 0.73, and 0.80, respectively. The sensitivity values for ANN, LR and SVM were 71.2%, 72.9% and 83.1%, while the specificity values for ANN, LR and SVM were 59.1%, 63.6% and 63.6%, respectively. Meanwhile, the CSA based strategy outperformed SFS and SA in terms of AUC, sensitivity and specificity. Based on clinical parameters, the SVM with the CSA optimal parameter set selection strategy achieves better performance than other strategies for predicting distant failure in lung SBRT patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Lung Ultrasonography to Diagnose Transient Tachypnea of the Newborn.
Liu, Jing; Chen, Xin-Xin; Li, Xiang-Wen; Chen, Shui-Wen; Wang, Yan; Fu, Wei
2016-05-01
This study explored the sensitivity and specificity of ultrasound for diagnosing transient tachypnea of the newborn (TTN). Ultrasound was performed by one export. Patients were placed in a supine, lateral recumbent, or prone position. The probe was placed perpendicular or parallel to the ribs, and each region of the lung was scanned. The scan results were compared with conventional chest radiographic results. A total of 1,358 infants were included in this study. We identified 412 cases without pulmonary diseases, 228 TTN cases, 358 respiratory distress syndrome (RDS) cases, 85 meconium aspiration syndrome (MAS) cases, 215 infectious pneumonia cases, and 60 other cases. The primary ultrasonic characteristic of TTN was pulmonary edema. "White lung" or a "compact B-line" were only observed in severe cases, whereas TTN primarily presented as pulmonary interstitial syndrome or "double lung point." Furthermore, double lung point could appear during the recovery period of severe TTN or RDS, MAS, and pneumonia. Lung consolidation with air bronchograms was not observed in TTN patients. The results showed that white lung or a compact B-line exhibited a sensitivity of 33.8% and a specificity of 91.3% in diagnosing TTN, whereas double lung point exhibited a sensitivity of 45.6% and a specificity of 94.8% in diagnosing severe TTN. Pulmonary edema, alveolar-interstitial syndrome, double lung point, white lung, and compact B-line are the primary ultrasound characteristics of TTN. Ultrasonic diagnosis of TTN based on these findings is accurate and reliable. TTN can be ruled out in the presence of lung consolidation with air bronchograms. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Ultrasound for Distal Forearm Fracture: A Systematic Review and Diagnostic Meta-Analysis
Douma-den Hamer, Djoke; Blanker, Marco H.; Edens, Mireille A.; Buijteweg, Lonneke N.; Boomsma, Martijn F.; van Helden, Sven H.; Mauritz, Gert-Jan
2016-01-01
Study Objective To determine the diagnostic accuracy of ultrasound for detecting distal forearm fractures. Methods A systematic review and diagnostic meta-analysis was performed according to the PRISMA statement. We searched MEDLINE, Web of Science and the Cochrane Library from inception to September 2015. All prospective studies of the diagnostic accuracy of ultrasound versus radiography as the reference standard were included. We excluded studies with a retrospective design and those with evidence of verification bias. We assessed the methodological quality of the included studies with the QUADAS-2 tool. We performed a meta-analysis of studies evaluating ultrasound to calculate the pooled sensitivity and specificity with 95% confidence intervals (CI95%) using a bivariate model with random effects. Subgroup and sensitivity analysis were used to examine the effect of methodological differences and other study characteristics. Results Out of 867 publications we included 16 studies with 1,204 patients and 641 fractures. The pooled test characteristics for ultrasound were: sensitivity 97% (CI95% 93–99%), specificity 95% (CI95% 89–98%), positive likelihood ratio (LR) 20.0 (8.5–47.2) and negative LR 0.03 (0.01–0.08). The corresponding pooled diagnostic odds ratio (DOR) was 667 (142–3,133). Apparent differences were shown for method of viewing, with the 6-view method showing higher specificity, positive LR, and DOR, compared to the 4-view method. Conclusion The present meta-analysis showed that ultrasound has a high accuracy for the diagnosis of distal forearm fractures in children when used by proper viewing method. Based on this, ultrasound should be considered a reliable alternative, which has the advantages of being radiation free. PMID:27196439
Poliomyelitis case confirmation: characteristics for use by national eradication programmes.
Biellik, R. J.; Bueno, H.; Olive, J. M.; de Quadros, C.
1992-01-01
Highly sensitive case definitions were first introduced by national poliomyelitis eradication programmes to avoid missing true cases of the disease, though false-positive diagnostic errors could still occur owing to low specificity. Extensive data from all 1620 cases of acute, flaccid paralysis reported in Brazil during 1987-88 provided an opportunity to study the characteristics of confirmed poliomyelitis cases and epidemiologically to evaluate potential case definitions that maximized both sensitivity and specificity. Cases that had been confirmed by wild poliomyelitis virus isolation were compared with those that had been rejected (non-polio cases). To guarantee the consistency of clinical, epidemiological and laboratory investigations, only cases less than 10 years of age that had been investigated within 15 days of the onset and with complete laboratory specimens were included. No single practical case definition combining both high sensitivity and high specificity emerged from the study. However, the results showed that poliomyelitis endemic countries with limited resources should give priority to the investigation of cases in less than 5-year-olds, cases with prodromal fever, cases without involvement in all four limbs, cases without progression greater than 3 days after the onset, and cases occurring in areas where poliomyelitis had recently been confirmed. In countries without laboratory resources, cases of acute, flaccid paralysis with initial involvement in one or both lower limbs and residual neurological sequelae at 60 days should be confirmed. Countries that are close to eradication may selectively reject any cases lacking laboratory confirmation, despite adequate specimen collection, if they do not have initial involvement in one or both lower limbs and residual neurological sequelae at 60 days. PMID:1314710
Opiate-sensitivity: clinical characteristics and the role of skin prick testing.
Nasser, S M; Ewan, P W
2001-07-01
The value of skin prick testing in opiate-sensitive individuals is uncertain as opiates cause non-specific weals by direct degranulation of mast cells. To define whether skin prick test (SPT) responses to opiates in opiate-sensitive individuals are different to those seen in the normal population and to describe the clinical characteristics of this group of subjects. The SPT responses of eight opiate-sensitive subjects to morphine 10 mg/mL, pethidine (meperidine) 50 mg/mL and papaveretum 15.4 mg/mL at four different concentrations (undiluted, 1/10, 1/50 and 1/100) were compared with the responses of 100 (32 atopic) non-opiate-sensitive control subjects. Four of the opiate-sensitive subjects had a clinical history of asthma, rhinitis or urticaria on occupational exposure to morphine. One subject developed urticaria with codeine, one developed urticaria and asthma with morphine and diamorphine and two subjects reacted to intravenous papaveretum with anaphylaxis or urticaria. Five out of the eight cases had opiate sensitivity confirmed by single-blind placebo-controlled oral challenge. Skin prick tests to all three opiates were not significantly different when the eight opiate-sensitive subjects were compared with either the entire normal control group or the subgroup of 47 definite opiate-tolerant controls that had previously received opiates for clinical indications. Furthermore, there were no significant differences in size of opiate SPT responses between atopic and non-atopic control subjects. In the control subjects, there was a positive correlation in SPT weal size between the three opiates. Skin prick testing is not useful in the diagnosis of opiate sensitivity and placebo-controlled challenge should be considered.
Cohen, Lisa J; Tanis, Thachell; Ardalan, Firouz; Yaseen, Zimri; Galynker, Igor
2016-08-30
Diagnostic criteria for borderline personality disorder (BPD) and mood and psychotic disorders characterized by major mood episodes (i.e., major depressive, bipolar and schizoaffective disorder) share marked overlap in symptom presentation, complicating differential diagnosis. The current study tests the hypothesis that maladaptive interpersonal schemas (MIS) are characteristic of BPD, but not of the major mood disorders. One hundred psychiatric inpatients were assessed by SCID I, SCID II and the Young Schema Questionnaire (YSQ-S2). Logistic regression analyses tested the association between MIS (measured by the YSQ-S2) and BPD, bipolar, major depressive and schizoaffective disorder. Receiver operator characteristic (ROC) curve analyses assessed the sensitivity and specificity of MIS as a marker of BPD. After covariation for comorbidity with each of the 3 mood disorders, BPD was robustly associated with 4 out of 5 schema domains. In contrast, only one of fifteen regression analyses demonstrated a significant association between any mood disorder and schema domain after covariation for comorbid BPD. ROC analyses of the 5 schema domains suggested Disconnection/Rejection had the greatest power for identification of BPD cases. These data support the specific role of maladaptive interpersonal schemas in BPD and potentially contribute to greater conceptual clarity about the distinction between BPD and the major mood disorders. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Biaoxue, Rong; Shuanying, Yang
2018-01-01
Many studies have evaluated the accuracy of EGFR mutation status in blood against that in tumor tissues as the reference. We conducted this systematic review and meta-analysis to assess whether blood can be used as a substitute for tumor tissue in detecting EGFR mutations. Investigations that provided data on EGFR mutation status in blood were searched in the databases of Medline, Embase, Ovid Technologies and Web of Science. The detect efficiency of EGFR mutations in paired blood and tissues was compared using a random-effects model of meta-analysis. Pooled sensitivity and specificity and diagnostic accuracy were calculated by receiver operating characteristic curve. A total of 19 studies with 2,922 individuals were involved in this meta-analysis. The pooled results showed the positive detection rate of EGFR mutations in lung cancer tissues was remarkably higher than that of paired blood samples (odds ratio [OR] = 1.47, p<0.001). The pooled sensitivity and specificity of blood were 0.65 and 0.91, respectively, and the area under the receiver operating characteristic curve was 0.89. Although blood had a better specificity for detecting EGFR mutations, the absence of blood positivity should not necessarily be construed as confirmed negativity. Patients with negative results for blood should decidedly undergo further biopsies to ascertain EGFR mutations.
The Effect of the MassHealth Hospital Pay-for-Performance Program on Quality
Ryan, Andrew M; Blustein, Jan
2011-01-01
Objective To test the effect of Massachusetts Medicaid's (MassHealth) hospital-based pay-for-performance (P4P) program, implemented in 2008, on quality of care for pneumonia and surgical infection prevention (SIP). Data Hospital Compare process of care quality data from 2004 to 2009 for acute care hospitals in Massachusetts (N = 62) and other states (N = 3,676) and American Hospital Association data on hospital characteristics from 2005. Study Design Panel data models with hospital fixed effects and hospital-specific trends are estimated to test the effect of P4P on composite quality for pneumonia and SIP. This base model is extended to control for the completeness of measure reporting. Further sensitivity checks include estimation with propensity-score matched control hospitals, excluding hospitals in other P4P programs, varying the time period during which the program was assumed to have an effect, and testing the program effect across hospital characteristics. Principal Findings Estimates from our preferred specification, including hospital fixed effects, trends, and the control for measure completeness, indicate small and nonsignificant program effects for pneumonia (−0.67 percentage points, p>.10) and SIP (−0.12 percentage points, p>.10). Sensitivity checks indicate a similar pattern of findings across specifications. Conclusions Despite offering substantial financial incentives, the MassHealth P4P program did not improve quality in the first years of implementation. PMID:21210796
McNeill, C A; Allan, S A; Koehler, P G; Pereira, R M; Weeks, E N I
2016-12-01
Bed bugs as pests of public health importance recently experienced a resurgence in populations throughout the U.S. and other countries. Consequently, recent research efforts have focused on improving understanding of bed bug physiology and behaviour to improve management. While few studies have investigated the visual capabilities of bed bugs, the present study focused specifically on eye morphology and spectral sensitivity. A 3-D imaging technique was used to document bed bug eye morphology from the first instar through adult and revealed morphological characteristics that differentiate the common bed bug from the tropical bed bug as well as sex-specific differences. Electrophysiological measurements were used to evaluate the spectral sensitivity of adult bed bugs. Male bed bugs were more responsive than females at some wavelengths. Electrophysiological studies provided evidence for at least one photoreceptor with a spectral sensitivity curve peak in the green (λ max 520 nm) region of the spectrum. The broadened long wavelength portion of the spectral sensitivity curve may potentially indicate another photoreceptor in the yellow-green (λ max 550 nm) portion of the spectrum or screening pigments. Understanding more about bed bug visual biology is vital for designing traps, which are an important component of integrated bed bug management. © 2016 The Royal Entomological Society.
Kråkenes, Jostein; Brauckhoff, Katrin; Haugland, Hans Kristian; Heinecke, Achim; Akslen, Lars A; Varhaug, Jan Erik; Brauckhoff, Michael
2015-01-01
Background Positron emission tomography (PET) using fluor-18-deoxyglucose (18F-FDG) with or without computed tomography (CT) is generally accepted as the most sensitive imaging modality for diagnosing recurrent differentiated thyroid cancer (DTC) in patients with negative whole body scintigraphy with iodine-131 (I-131). Purpose To assess the potential incremental value of ultrasound (US) over 18F-FDG-PET-CT. Material and Methods Fifty-one consecutive patients with suspected recurrent DTC were prospectively evaluated using the following multimodal imaging protocol: (i) US before PET (pre-US) with or without fine needle biopsy (FNB) of suspicious lesions; (ii) single photon emission computed tomography (≥3 GBq I-131) with co-registered CT (SPECT-CT); (iii) 18F-FDG-PET with co-registered contrast-enhanced CT of the neck; (iv) US in correlation with the other imaging modalities (post-US). Postoperative histology, FNB, and long-term follow-up (median, 2.8 years) were taken as composite gold standard. Results Fifty-eight malignant lesions were identified in 34 patients. Forty lesions were located in the neck or upper mediastinum. On receiver operating characteristics (ROC) analysis, 18F-FDG-PET had a limited lesion-based specificity of 59% at a set sensitivity of 90%. Pre-US had poor sensitivity and specificity of 52% and 53%, respectively, increasing to 85% and 94% on post-US, with knowledge of the PET/CT findings (P < 0.05 vs. PET and pre-US). Multimodal imaging changed therapy in 15 out of 51 patients (30%). Conclusion In patients with suspected recurrent DTC, supplemental targeted US in addition to 18F-FDG-PET-CT increases specificity while maintainin sensitivity, as non-malignant FDG uptake in cervical lesions can be confirmed. PMID:25770086
Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa
2005-01-01
A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.
Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-01-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum. The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. PMID:27707942
Jewett, A; Smith, B D; Garfein, R S; Cuevas-Mota, J; Teshale, E H; Weinbaum, C M
2012-07-01
Approximately 4.1 million Americans are estimated to have been infected with hepatitis C virus (HCV), 45-85% of whom are unaware of their infection. Persons who inject drugs (PWID) account for 55.8% of all persons with HCV antibody (anti-HCV) in the U.S. PWID have limited access to healthcare and are infrequently tested for anti-HCV using conventional laboratory assays. To evaluate performance characteristics (sensitivity and specificity) of three, pre-market rapid point-of-care tests (one oral fluid and two finger-stick assays) from two manufacturers (Chembio and MedMira) in settings providing services to young adult PWID in San Diego, CA. Behavioral risk assessment surveys and testing for HCV were conducted among persons who reported injection drug use (IDU) within the past 6 months as part of the Study to Assess Hepatitis C Risk (STAHR) among PWID aged 18-40 years in 2009-2010. Sensitivity and specificity of the rapid anti-HCV assays were evaluated among STAHR participants, using two commonly used testing algorithms. Variability in sensitivity (76.6-97.1%) and specificity (99.0-100.0%) was found across assays. The highest sensitivity achieved for the Chembio finger-stick blood, Chembio oral fluid and MedMira finger-stick blood tests was 97.1%, 85.4% and 80.0% respectively; the highest specificity was 99.0%, 100.0% and 100.0%, respectively. In multivariate analysis false negative anti-HCV results were associated with female sex for the MedMira blood assay. Sensitive anti-HCV rapid assays are appropriate and feasible for high-prevalence, high-risk populations such as young PWID. Copyright © 2012 Elsevier B.V. All rights reserved.
Shastri, Surendra S; Dinshaw, Ketayun; Amin, Geetanjali; Goswami, Smriti; Patil, Sharmila; Chinoy, Roshini; Kane, S; Kelkar, Rohini; Muwonge, Richard; Mahé, Cédric; Ajit, Dulhan; Sankaranarayanan, R
2005-03-01
Naked eye visual inspection with acetic acid (VIA), magnified VIA (VIAM), visual inspection with Lugol's iodine (VILI), cytology and human papillomavirus (HPV) testing were evaluated as screening methods for the detection of high-grade squamous intraepithelial lesions (HSIL) of the uterine cervix in a cross-sectional study in Mumbai, India. Cytology, HPV testing, VIA, VIAM and VILI were carried out concurrently for 4039 women aged 30-65 years. All women were investigated with colposcopy and biopsies were taken from 939 women who had colposcopic abnormalities. The reference standard for final disease status was histology or negative colposcopy. The presence of HSIL was confirmed in 57 women (1.4%). The test characteristics for each method were calculated using standard formulae. The sensitivities of cytology, HPV testing, VIA, VIAM and VILI were 57.4%, 62.0%, 59.7%, 64.9%, and 75.4%, respectively (differences were not statistically significant). The specificities were 98.6%, 93.5%, 88.4%, 86.3%, and 84.3%, respectively. Adding a visual test to cytology or HPV testing in parallel combination resulted in a substantial increase in sensitivity, with a moderate decrease in specificity. The parallel combination of VILI and HPV testing resulted in a sensitivity of 92.0% and a specificity of 79.9%. As a single test, cytology had the best balance of sensitivity and specificity. Visual tests are promising in low-resource settings, such as India. The use of both VIA and VILI may be considered where good quality cytology or HPV testing are not feasible. The sensitivity of cytology and HPV testing increased significantly when combined with VIA or VILI.
Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B
2013-06-01
Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.
Raifu, Amidu O.; El-Zein, Mariam; Sangwa-Lugoma, Ghislain; Ramanakumar, Agnihotram; Walter, Stephen D.
2017-01-01
Background Visual inspection with acetic acid (VIA) and Lugol’s iodine (VILI) are used to screen women for cervical cancer in low-resource settings. Little is known about correlates of their diagnostic accuracy by healthcare provider. We examined determinants of VIA and VILI screening accuracy by examiner in a cross-sectional screening study of 1528 women aged 30 years or older in a suburb of Kinshasa, Democratic Republic of Congo. Methods We used a logistic regression model for sensitivity and specificity to estimate the diagnostic accuracy of VIA and VILI, independently performed by nurse and physician, as a function of sociodemographic and reproductive health characteristics. Results Nurses rated tests as positive more often than physicians (36.3% vs 30.2% for VIA, 26.2% vs 25.2% for VILI). Women’s age was the most important determinant of performance. It was inversely associated with sensitivity (nurse’s VIA: p<0.001, nurse’s VILI: p = 0.018, physician’s VIA: p = 0.005, physician’s VILI: p = 0.006) but positively associated with specificity (all four combinations: p<0.001). Increasing parity adversely affected sensitivity and specificity, but the effects on sensitivity were significant for nurses only. The screening performance of physician’s assessment was significantly better than the nurse’s (difference in sensitivity: VIA = 13%, VILI = 16%; difference in specificity: VIA = 6%, VILI = 1%). Conclusions Age and parity influence the performance of visual tests for cervical cancer screening. Proper training of local healthcare providers in the conduct of these tests should take into account these factors for improved performance of VIA and VILI in detecting cervical precancerous lesions among women in limited-resource settings. PMID:28107486
Jun, Zhou; Zhen, Chen; QuiuLi, Zhang; YuanQi, An; Casado, Verónica Vocero; Fan, Yuan
2016-12-01
Currently, conventional enzyme immunoassays which use manual gold immunoassays and colloidal tests (GICTs) are used as screening tools to detect Treponema pallidum (syphilis), hepatitis B virus (HBV), hepatitis C virus (HCV), human immunodeficiency virus type 1 (HIV-1), and HIV-2 in patients undergoing surgery. The present observational, cross-sectional study compared the sensitivity, specificity, and work flow characteristics of the conventional algorithm with manual GICTs with those of a newly proposed algorithm that uses the automated Bio-Flash technology as a screening tool in patients undergoing gastrointestinal (GI) endoscopy. A total of 956 patients were examined for the presence of serological markers of infection with HIV-1/2, HCV, HBV, and T. pallidum The proposed algorithm with the Bio-Flash technology was superior for the detection of all markers (100.0% sensitivity and specificity for detection of anti-HIV and anti-HCV antibodies, HBV surface antigen [HBsAg], and T. pallidum) compared with the conventional algorithm based on the manual method (80.0% sensitivity and 98.6% specificity for the detection of anti-HIV, 75.0% sensitivity for the detection of anti-HCV, 94.7% sensitivity for the detection of HBsAg, and 100% specificity for the detection of anti-HCV and HBsAg) in these patients. The automated Bio-Flash technology-based screening algorithm also reduced the operation time by 85.0% (205 min) per day, saving up to 24 h/week. In conclusion, the use of the newly proposed screening algorithm based on the automated Bio-Flash technology can provide an advantage over the use of conventional algorithms based on manual methods for screening for HIV, HBV, HCV, and syphilis before GI endoscopy. Copyright © 2016 Jun et al.
Simental-Mendía, Luis E; Simental-Mendía, Esteban; Rodríguez-Hernández, Heriberto; Rodríguez-Morán, Martha; Guerrero-Romero, Fernando
2016-01-01
Introduction and aim. Given that early identification of non-alcoholic fatty liver disease (NAFLD) is an important issue for primary prevention of hepatic disease, the objectives of this study were to evaluate the efficacy of the product of triglyceride and glucose levels (TyG) for screening simple steatosis and non-alcoholic steatohepatitis (NASH) in asymptomatic women, and to compare its efficacy vs. other biomarkers for recognizing NAFLD. Asymptomatic women aged 20 to 65 years were enrolled into a cross-sectional study. The optimal values of TyG, for screening simple steatosis and NASH were established on a Receiver Operating Characteristic scatter plot; the sensitivity, specificity, and likelihood ratios of TyG index were estimated versus liver biopsy. According sensitivity and specificity, the efficacy of TyG was compared versus the well-known clinical biomarkers for recognizing NAFLD. A total of 50 asymptomatic women were enrolled. The best cutoff point of TyG for screening simple steatosis was 4.58 (sensitivity 0.94, specificity 0.69); in addition, the best cutoff point of TyG index for screening NASH was 4.59 (sensitivity 0.87, specificity 0.69). The positive and negative likelihood ratios were 3.03 and 0.08 for simple steatosis, and 2.80 and 0.18 for NASH. As compared versus SteatoTest, NashTest, Fatty liver index, and Algorithm, the TyG showed to be the best test for screening. TyG has high sensitivity and low negative likelihood ratio; as compared with other clinical biomarkers, the TyG showed to be the best test for screening simple steatosis and NASH.
Chang, Ming-Chu; Liang, Po-Chin; Jan, I-Shiow; Yang, Ching-Yao; Tien, Yu-Wen; Wei, Shu-Chen; Wong, Jau-Min; Chang, Yu-Ting
2014-08-18
The International Consensus Diagnostic Criteria (ICDC) designed to diagnosis autoimmune pancreatitis (AIP) has been proposed recently. The diagnostic performance of ICDC has not been previously evaluated in diffuse-type and focal-type AIP, respectively, in comparison with the revised HISORt and Asian criteria in Taiwan. Prospective, consecutive patient cohort. Largest tertiary referred centre hospital managing pancreatic disease in Taiwan. 188 patients with AIP and 130 with tissue proofed pancreatic adenocarcinoma were consecutively recruited. The ICDC, as well as revised HISORt and Asian criteria, was applied for each participant. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in diffuse-type and focal-type AIP. Sensitivity, specificity and accuracy. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in AIP and focal-type AIP. The sensitivity, specificity and accuracy of ICDC for all AIP were the best: 89.4%, 100% and 93.7%, respectively, in these three criteria. The sensitivity, specificity and accuracy of ICDC for focal-type AIP (84.9%, 100% and 93.8%) were also the best among these three criteria. The area under the curve of receiver-operator characteristic of ICDC was 0.95 (95% CI 0.92 to 0.97) in all AIP and 0.93 (95% CI 0.88 to 0.97) in focal-type AIP. The sensitivity, specificity and accuracy of ICDC are higher than the revised HISORt and Asian criteria. The sensitivity, specificity and accuracy of each criterion are higher in diffuse-type AIP compared with focal-type AIP. Under the same specificity, the sensitivity and accuracy of ICDC are higher than other diagnostic criteria in focal-type AIP. ICDC has better diagnostic performance compared with previously proposed diagnostic criteria in diffuse-type and focal-type AIP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Hamel, Perrine; Falinski, Kim; Sharp, Richard; Auerbach, Daniel A; Sánchez-Canales, María; Dennedy-Frank, P James
2017-02-15
Geospatial models are commonly used to quantify sediment contributions at the watershed scale. However, the sensitivity of these models to variation in hydrological and geomorphological features, in particular to land use and topography data, remains uncertain. Here, we assessed the performance of one such model, the InVEST sediment delivery model, for six sites comprising a total of 28 watersheds varying in area (6-13,500km 2 ), climate (tropical, subtropical, mediterranean), topography, and land use/land cover. For each site, we compared uncalibrated and calibrated model predictions with observations and alternative models. We then performed correlation analyses between model outputs and watershed characteristics, followed by sensitivity analyses on the digital elevation model (DEM) resolution. Model performance varied across sites (overall r 2 =0.47), but estimates of the magnitude of specific sediment export were as or more accurate than global models. We found significant correlations between metrics of sediment delivery and watershed characteristics, including erosivity, suggesting that empirical relationships may ultimately be developed for ungauged watersheds. Model sensitivity to DEM resolution varied across and within sites, but did not correlate with other observed watershed variables. These results were corroborated by sensitivity analyses performed on synthetic watersheds ranging in mean slope and DEM resolution. Our study provides modelers using InVEST or similar geospatial sediment models with practical insights into model behavior and structural uncertainty: first, comparison of model predictions across regions is possible when environmental conditions differ significantly; second, local knowledge on the sediment budget is needed for calibration; and third, model outputs often show significant sensitivity to DEM resolution. Copyright © 2016 Elsevier B.V. All rights reserved.
Structural and functional assessment of macula to diagnose glaucoma.
Rao, H L; Hussain, R S M; Januwada, M; Pillutla, L N; Begum, V U; Chaitanya, A; Senthil, S; Garudadri, C S
2017-04-01
PurposeTo compare the diagnostic abilities of structural (ganglion cell-inner plexiform layer (GCIPL) thickness measured using spectral domain optical coherence tomography (SDOCT)) and functional (visual sensitivities measured using standard automated perimetry (SAP) and microperimetry (MP)) assessments of macula in glaucoma.MethodsIn a prospective study, 46 control eyes (28 subjects) and 61 glaucoma eyes (46 patients) underwent visual sensitivity estimation at macula (central 10°) by SAP and MP, and GCIPL thickness measurement at macula by SDOCT. Glaucoma was diagnosed by experts based on the optic disc and retinal nerve fiber layer changes. Area under the receiver-operating characteristic (AUC) curves and sensitivities at 95% specificity were used to assess the diagnostic ability of visual sensitivity and GCIPL measurements at various macular sectors.ResultsAUCs of GCIPL parameters ranged between 0.58 and 0.79. AUCs of SAP and MP sensitivities ranged between 0.59 and 0.71, and 0.59 and 0.72, respectively. There were no statistically significant differences between the AUCs of corresponding sector measurements (P>0.10 for all comparisons). Sensitivities at 95% specificities ranged from 31-59% for GCIPL parameters, 16-34% for SAP, and 8-38% for MP parameters. Sensitivities were significantly better with GCIPL compared with SAP and MP parameters in diagnosing glaucoma. Inferotemporal, inferior, and superotemporal sector measurements of GCIPL and visual sensitivity showed the best abilities to diagnose glaucoma.ConclusionsComparing the diagnostic abilities of structural and functional tests at macula in glaucoma, GCIPL thickness measurements with SDOCT performed better than the visual sensitivity measurements by SAP and MP.
Pugliese, Cara E.; Kenworthy, Lauren; Bal, Vanessa Hus; Wallace, Gregory L; Yerys, Benjamin E; Maddox, Brenna B.; White, Susan W.; Popal, Haroon; Armour, Anna Chelsea; Miller, Judith; Herrington, John D.; Schultz, Robert T.; Martin, Alex; Anthony, Laura Gutermuth
2015-01-01
Recent updates have been proposed to the Autism Diagnostic Observation Schedule-2 Module 4 diagnostic algorithm. This new algorithm, however, has not yet been validated in an independent sample without intellectual disability (ID). This multi-site study compared the original and revised algorithms in individuals with ASD without ID. The revised algorithm demonstrated increased sensitivity, but lower specificity in the overall sample. Estimates were highest for females, individuals with a verbal IQ below 85 or above 115, and ages 16 and older. Best practice diagnostic procedures should include the Module 4 in conjunction with other assessment tools. Balancing needs for sensitivity and specificity depending on the purpose of assessment (e.g., clinical vs. research) and demographic characteristics mentioned above will enhance its utility. PMID:26385796
Modeling rate sensitivity of exercise transient responses to limb motion.
Yamashiro, Stanley M; Kato, Takahide
2014-10-01
Transient responses of ventilation (V̇e) to limb motion can exhibit predictive characteristics. In response to a change in limb motion, a rapid change in V̇e is commonly observed with characteristics different than during a change in workload. This rapid change has been attributed to a feed-forward or adaptive response. Rate sensitivity was explored as a specific hypothesis to explain predictive V̇e responses to limb motion. A simple model assuming an additive feed-forward summation of V̇e proportional to the rate of change of limb motion was studied. This model was able to successfully account for the adaptive phase correction observed during human sinusoidal changes in limb motion. Adaptation of rate sensitivity might also explain the reduction of the fast component of V̇e responses previously reported following sudden exercise termination. Adaptation of the fast component of V̇e response could occur by reduction of rate sensitivity. Rate sensitivity of limb motion was predicted by the model to reduce the phase delay between limb motion and V̇e response without changing the steady-state response to exercise load. In this way, V̇e can respond more quickly to an exercise change without interfering with overall feedback control. The asymmetry between responses to an incremental and decremental ramp change in exercise can also be accounted for by the proposed model. Rate sensitivity leads to predicted behavior, which resembles responses observed in exercise tied to expiratory reserve volume. Copyright © 2014 the American Physiological Society.
Rotchés-Ribalta, Roser; Boutin, Céline; Blanco-Moreno, José M; Carpenter, David; Sans, F Xavier
2015-07-01
The decline of arable species characteristic of winter cereal fields has often been attributed to different factors related to agricultural intensification but most importantly to herbicide use. Herbicide phytotoxicity is most frequently assessed using short-term endpoints, primarily aboveground biomass. However, short-term sensitivity is usually not sufficient to detect actual effects because plants may or may not recover over time following sublethal herbicide exposures. Therefore, it is important to assess the long-term effects of herbicide applications. Annual species rely on renewable seed production to ensure their persistence; hence, assessment of herbicide sensitivity is more accurately estimated through effects on reproduction. Here we aim to assess the phytotoxicity of two commonly used herbicides: tribenuron and 2,4-D on eight plant species belonging to four families, each with one rare and one more common species. Specifically we examined the pattern of sensitivity using short-term and long-term endpoints (total aboveground biomass, total seed biomass and number of seeds) of these species; we determined the levels of and time to recovery in terms of stem length and fruit number, and assessed whether their rarity relates to their sensitivity to herbicide application. Our results suggest that although differences in herbicide sensitivity are not a direct cause of rarity for all species, it may be an important driver of declining arable plants.
Brand, T; Kleer, D; Samkange-Zeeb, F; Zeeb, Hajo
2015-06-01
Health promotion and prevention can contribute to a long, healthy life in populations both with and without migrant background. This paper provides an overview on migrant participation in prevention programmes in Germany. Furthermore, we describe migrant sensitive prevention strategies and characteristics of prevention programmes for migrants in Germany. With regard to participation in prevention programmes, lower vaccination rates are found among children and adolescents who migrated to Germany after birth. Among adults with a migrant background, we found lower participation in general health check-ups, oral health check-ups, cancer screening programs and influenza vaccination. Migrant sensitive prevention strategies address the visual style of the material, a target group specific risk communication, language requirements, a systematic involvement of the target group, and the recognition of deeply rooted sociocultural practices and beliefs. On analyzing a large database on prevention programs in Germany, we found only a few programmes that were exclusively targeted to migrant groups (0.6%). In 16.6% of the programs migrants were addressed as the target group among others. Compared to general population programs, programs for migrants were more often exclusively directed towards girls or women. Moreover, programs for migrants used community-based approaches more often and addressed different age groups. Although information on migrant participation in prevention programs and utilization of migrant sensitive strategies is still incomplete, we can assume that there is a need for diversity-oriented, migrant sensitive prevention.
Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita
2017-05-01
To examined the diagnostic value of dilatation and curettage (D and C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D and C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to AUB and who had undergone hysterectomy were investigated. The patients' characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D and C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D and C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps.
Moradan, Sanam; Ghorbani, Raheb; Lotfi, Azita
2017-01-01
Objectives: To examined the diagnostic value of dilatation and curettage (D&C) in patients with abnormal uterine bleeding (AUB) by conducting a histopathological examination of endometrial tissues by D&C and hysterectomy. Methods: In this retrospective study, the medical records of 163 women who had been hospitalized in the Obstetrics and Gynecology Ward, Amir-al-Momenin Hospital, Semnan, Iran between 2010 and 2015 for diagnostic curettage due to AUB and who had undergone hysterectomy were investigated. The patients’ characteristics and histopathologic results of curettage and hysterectomy were extracted, and sensitivity and specificity and positive and negative predictive values of curettage were calculated. Results: The mean ± standard deviation age of the patients was 49.8±7.8 years. The sensitivity values of D&C in the diagnosis of endometrial pathologies was 49.1%, specificity 84.5%, positive 60.5%, and negative predictive 77.5%. The sensitivities of D&C in the diagnosis of various endometrial hyperplasia was 62.5%, disordered proliferative endometrium 36.8%, and endometrial cancer 83.3%. Of 6 patients with endometrial polyps on performing hysterectomy, no patient was diagnosed by curettage. Conclusions: Dilatation and curettage has acceptable sensitivity in the diagnosis of endometrial cancer, low sensitivity in the diagnosis of endometrial hyperplasia, and very low sensitivity in the diagnosis of disordered proliferative endometrium and endometrial polyps. PMID:28439599
Erickson, Dana; Singh, Ravinder J; Sathananthan, Airani; Vella, Adrian; Bryant, Sandra C
2012-04-01
Late-night salivary cortisol (LNSC) measurements have been increasingly used by physicians as an initial diagnostic test for evaluation of patients with clinical suspicion of Cushing's syndrome (CS). Published studies include various numbers of cases, controls and importantly, various assay methods (vast majority various immunoassays), as well as various methods to generate cut-points. The retrospective study evaluated the diagnostic utility of LNSC measurements in 249 patients evaluated for possibility of CS because of various clinical conditions using liquid chromatography/tandem mass spectrometry method (LC-MS/MS). CS was confirmed in 47 patients (18·9%) and excluded in 202 (81·1%) patients at the time of analysis. Late-night salivary cortisol was abnormal or >2·8 nmol/l in 35 of 47 patients with CS; sensitivity of 74·5% and elevated in 20 of 202 patients who were found not to have CS; specificity 90·1%. Using receiver-operator characteristic statistics for calculation of the most optimal sensitivity and specificity, the cut-off based on this data was LNSC > 2·1 nmol/l with sensitivity of 83·0% and specificity of 84·2%. Analysis of data at one referral institution showed somewhat limited sensitivity of LNSC for diagnosis of CS using current reference ranges. © 2012 Blackwell Publishing Ltd.
Asao, Keiko; McEwen, Laura N.; Lee, Joyce M.; Herman, William H.
2015-01-01
Aims To estimate and evaluate the sensitivity and specificity of providers’ diagnosis codes and medication lists to identify outpatient visits by patients with diabetes. Methods We used data from the 2006 to 2010 National Ambulatory Medical Care Survey and National Hospital Ambulatory Medical Care Survey. We assessed the sensitivity and specificity of providers’ diagnoses and medication lists to identify patients with diabetes, using the checkbox for diabetes as the gold standard. We then examined differences in sensitivity by patients’ characteristics using multivariate logistic regression models. Results The checkbox identified 12,647 outpatient visits by adults with diabetes among the 70,352 visits used for this analysis. The sensitivity and specificity of providers’ diagnoses or listed diabetes medications were 72.3% (95% CI: 70.8% to 73.8%) and 99.2% (99.1% to 99.4%), respectively. Diabetic patients ≥75 years pf age, women, non-Hispanics, and those with private insurance or Medicare were more likely to be missed by providers’ diagnoses and medication lists. Diabetic patients who had more diagnosis codes and medications recorded, had glucose or hemoglobin A1c measured, or made office- rather than hospital-outpatient visits were less likely to be missed. Conclusions Providers’ diagnosis codes and medication lists fail to identify approximately one quarter of outpatient visits by patients with diabetes. PMID:25891975
Baheza, Richard A.; Welch, E. Brian; Gochberg, Daniel F.; Sanders, Melinda; Harvey, Sara; Gore, John C.; Yankeelov, Thomas E.
2015-01-01
Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragments within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm)3 and (0.6 mm)3. In images acquired at 7 T with voxel sizes of (0.2 mm)3–(0.4 mm)3, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm)3–(0.6 mm)3, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance. PMID:25735297
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baheza, Richard A.; Welch, E. Brian; Gochberg, Daniel F.
Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragmentsmore » within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm){sup 3} and (0.6 mm){sup 3}. In images acquired at 7 T with voxel sizes of (0.2 mm){sup 3}–(0.4 mm){sup 3}, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm){sup 3}–(0.6 mm){sup 3}, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance.« less
Adolescents and Alcohol: Acute Sensitivities, Enhanced Intake, and Later Consequences*
Spear, Linda Patia
2014-01-01
Adolescence is an evolutionarily conserved developmental period characterized by notable maturational changes in brain along with various age-related behavioral characteristics, including the propensity to initiate alcohol and other drug use and consume more alcohol per occasion than adults. After a brief review of adolescent neurobehavioral function from an evolutionary perspective, the paper will turn to assessment of adolescent alcohol sensitivity and consequences, with a focus on work from our laboratory. After summarizing evidence showing that adolescents differ considerably from adults in their sensitivity to various effects of alcohol, potential contributors to these age-typical sensitivities will be discussed, and the degree to which these findings are generalizable to other drugs and to human adolescents will be considered. Recent studies are then reviewed to illustrate that repeated alcohol exposure during adolescence induces behavioral, cognitive, and neural alterations that are highly specific, replicable, persistent and dependent on the timing of the exposure. Research in this area is in its early stages, however, and more work will be necessary to characterize the extent of these neurobehavioral alterations and further determine the degree to which observed effects are specific to alcohol exposure during adolescence. PMID:24291291
Ritchie, Brianne M; Connors, Jean M; Sylvester, Katelyn W
2017-04-01
Previous studies have demonstrated optimized diagnostic accuracy in utilizing higher antiheparin-platelet factor 4 (PF4) enzyme-linked immunosorbent assay (ELISA) optical density (OD) thresholds for diagnosing heparin-induced thrombocytopenia (HIT). We describe the incidence of positive serotonin release assay (SRA) results, as well as performance characteristics, for antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units in the diagnosis of HIT at our institution. Following institutional review board approval, we conducted a single-center retrospective chart review on adult inpatients with a differential diagnosis of HIT evaluated by both antiheparin-PF4 ELISA and SRA from 2012 to 2014. The major endpoints were to assess incidence of positive SRA results, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy at antiheparin-PF4 ELISA values ≥0.4 OD units when compared to values ≥0.8 and ≥1.0 OD units. Clinical characteristics, including demographics, laboratory values, clinical and safety outcomes, length of stay, and mortality, were collected. A total of 140 patients with 140 antiheparin-PF4 ELISA and SRA values were evaluated, of which 23 patients were SRA positive (16.4%) and 117 patients were SRA negative (83.6%). We identified a sensitivity of 91.3% versus 82.6% and 73.9%, specificity of 61.5% versus 87.2% and 91.5%, PPV of 31.8% versus 55.9% and 63.0%, NPV of 97.3% versus 96.2% and 94.7%, and accuracy of 66.4% versus 86.4% and 88.6% at antiheparin-PF4 ELISA thresholds ≥0.4, ≥0.8, and ≥1.0 OD units, respectively. Our study suggests an increased antiheparin-PF4 ELISA threshold of 0.8 or 1.0 OD units enhances specificity, PPV, and accuracy while maintaining NPV with decreased sensitivity.
De Angelis, C; Onori, S; Pacilio, M; Cirrone, G A P; Cuttone, G; Raffaele, L; Bucciolini, M; Mazzocchi, S
2002-02-01
The dosimetric properties of two PTW Riga diamond detectors type 60003 were studied in high-energy photon and electron therapy beam. Properties under study were current-voltage characteristic, polarization effect, time stability of response, dose response, dose-rate dependence, temperature stability, and beam quality dependence of the sensitivity factor. Differences were shown between the two detectors for most of the previous properties. Also, the observed behavior was, to some extent, different from what was reported in the PTW technical specifications. The necessity to characterize each diamond detector individually was addressed.
Whitehouse, Chris A.; Chase, Kitty; Embers, Monica E.; Kulesh, David A.; Ladner, Jason T.; Palacios, Gustavo F.; Minogue, Timothy D.
2016-01-01
Background Moraxella macacae is a recently described bacterial pathogen that causes epistaxis or so-called bloody nose syndrome in captive macaques. The aim of this study was to develop specific molecular diagnostic assays for M. macacae and to determine their performance characteristics. Methods We developed six real-time PCR assays on the Roche LightCycler. The accuracy, precision, selectivity, and limit of detection (LOD) were determined for each assay, in addition to further validation by testing nasal swabs from macaques presenting with epistaxis at the Tulane National Primate Research Center. Results All assays exhibited 100% specificity and were highly sensitive with an LOD of 10 fg for chromosomal assays and 1 fg for the plasmid assay. Testing of nasal swabs from 10 symptomatic macaques confirmed the presence of M. macacae in these animals. Conclusions We developed several accurate, sensitive, and species-specific real-time PCR assays for the detection of M. macacae in captive macaques. PMID:26365904
Lukic, Ivana; Filipovic, Ana; Inic-Kanada, Aleksandra; Marinkovic, Emilija; Miljkovic, Radmila; Stojanovic, Marijana
2018-05-15
Oligoclonal combinations of several monoclonal antibodies (MAbs) are being considered for the treatment of various infectious pathologies. These combinations are less sensitive to antigen structural changes than individual MAbs; at the same time, their characteristics can be more efficiently controlled than those of polyclonal antibodies. The main goal of this study was to evaluate the binding characteristics of six biclonal equimolar preparations (BEP) of tetanus toxin (TeNT)-specific MAbs and to investigate how the MAb combination influences the BEPs' protective capacity. We show that a combination of TeNT-specific MAbs, which not only bind TeNT but also exert positive cooperative effects, results in a BEP with superior binding characteristics and protective capacity, when compared with the individual component MAbs. Furthermore, we show that a MAb with only partial protective capacity but positive effects on the binding of the other BEP component can be used as a valuable constituent of the BEP. Copyright © 2018 Elsevier Ltd. All rights reserved.
An alternative respiratory sounds classification system utilizing artificial neural networks.
Oweis, Rami J; Abdulhay, Enas W; Khayal, Amer; Awad, Areen
2015-01-01
Computerized lung sound analysis involves recording lung sound via an electronic device, followed by computer analysis and classification based on specific signal characteristics as non-linearity and nonstationarity caused by air turbulence. An automatic analysis is necessary to avoid dependence on expert skills. This work revolves around exploiting autocorrelation in the feature extraction stage. All process stages were implemented in MATLAB. The classification process was performed comparatively using both artificial neural networks (ANNs) and adaptive neuro-fuzzy inference systems (ANFIS) toolboxes. The methods have been applied to 10 different respiratory sounds for classification. The ANN was superior to the ANFIS system and returned superior performance parameters. Its accuracy, specificity, and sensitivity were 98.6%, 100%, and 97.8%, respectively. The obtained parameters showed superiority to many recent approaches. The promising proposed method is an efficient fast tool for the intended purpose as manifested in the performance parameters, specifically, accuracy, specificity, and sensitivity. Furthermore, it may be added that utilizing the autocorrelation function in the feature extraction in such applications results in enhanced performance and avoids undesired computation complexities compared to other techniques.
NASA Astrophysics Data System (ADS)
Petrie, M. D.; Brunsell, N. A.; Vargas, R.; Collins, S. L.
2013-12-01
Grassland and rangeland ecoregions extend across the North American continent and exhibit diversity in climate, ecosystem services, and biophysical processes. In many grasslands and rangelands, the potential for reductions in ecosystem services and for large-scale ecosystem state change may increase under future climate scenarios. Climate change projections for North America vary, however, and the way changing climate will influence specific ecoregions is largely unknown. To better understand the regional effects of climate change on grasslands and rangelands, it is important to better understand the biophysical characteristics of these systems locally, and to identify the sensitivity of these characteristics to observed climate variation. In our study, we propose to use eddy covariance, soil moisture and precipitation data to identify how the grasslands and rangelands of North America differ in their responses to climate variability through time, with specific focus on the active growing season. Our primary goal is to determine the sensitivity of ecosystem Net Primary Productivity [NPP] to variation in temperature and precipitation patterns, and classify North American grasslands and rangelands by these sensitivities in addition to more standard climate and productivity variables. Our preliminary analyses in mesic, semiarid and arid grasslands in Kansas, Colorado and New Mexico show significant (P < 0.05) differences in climate, carbon sink strength and growing season length, and suggest that patterns of seasonal productivity and precipitation sensitivity may elucidate important grassland and rangeland responses to changing climate. Using change in Gross Primary Productivity (GPP) as an indicator of the onset of photosynthesis in spring and of senescense in the fall, grassland and rangeland ecosystems in Kansas (top and bottom left panels) and New Mexico (bottom right panel) display differing patterns of activity throughout the year.
Transabdominal ultrasonography as a screening test for second-trimester placenta previa.
Quant, Hayley S; Friedman, Alexander M; Wang, Eileen; Parry, Samuel; Schwartz, Nadav
2014-03-01
To determine the test characteristics of transabdominal ultrasonography as a screening test for second-trimester placenta previa. This secondary analysis of a prospective cohort study evaluated the distance from the placental edge to the internal os (placenta-cervix distance) through both transabdominal and transvaginal ultrasonography during the anatomic survey. Patients were recruited in the Maternal-Fetal Medicine Ultrasound Unit at the Hospital of the University of Pennsylvania, an urban tertiary care center. Transabdominal placenta-cervix distance cutoffs with high sensitivity for detection of previa and low-lying placenta were identified, and test characteristics were calculated. Follow-up ultrasound data, pregnancy, and delivery outcomes for those with second-trimester previa or low-lying placenta were obtained. One thousand two hundred fourteen women were included in the analysis. A transabdominal placenta-cervix distance cutoff of 4.2 cm was 93.3% sensitive and 76.7% specific for detection of previa with a 99.8% negative predictive value at a screen-positive rate of 25.0%. A cutoff of 2.8 cm was 86.7% sensitive and 90.5% specific with a 99.6% negative predictive value at a screen-positive rate of 11.4%. Only 9.8% (four of 41) of previas and low-lying placentas persisted through delivery. Transabdominal ultrasonography is an effective screening test for second-trimester placenta previa. At centers not performing universal transvaginal ultrasonography at the time of the anatomic survey, evidence-based transabdominal placenta-cervix distance cutoffs can optimize the identification of patients who require further surveillance for previa.
Base Heating Sensitivity Study for a 4-Cluster Rocket Motor Configuration in Supersonic Freestream
NASA Technical Reports Server (NTRS)
Mehta, Manish; Canabal, Francisco; Tashakkor, Scott B.; Smith, Sheldon D.
2011-01-01
In support of launch vehicle base heating and pressure prediction efforts using the Loci-CHEM Navier-Stokes computational fluid dynamics solver, 35 numerical simulations of the NASA TND-1093 wind tunnel test have been modeled and analyzed. This test article is composed of four JP-4/LOX 500 lbf rocket motors exhausting into a Mach 2 - 3.5 wind tunnel at various ambient pressure conditions. These water-cooled motors are attached to a base plate of a standard missile forebody. We explore the base heating profiles for fully coupled finite-rate chemistry simulations, one-way coupled RAMP (Reacting And Multiphase Program using Method of Characteristics)-BLIMPJ (Boundary Layer Integral Matrix Program - Jet Version) derived solutions and variable and constant specific heat ratio frozen flow simulations. Variations in turbulence models, temperature boundary conditions and thermodynamic properties of the plume have been investigated at two ambient pressure conditions: 255 lb/sq ft (simulated low altitude) and 35 lb/sq ft (simulated high altitude). It is observed that the convective base heat flux and base temperature are most sensitive to the nozzle inner wall thermal boundary layer profile which is dependent on the wall temperature, boundary layer s specific energy and chemical reactions. Recovery shock dynamics and afterburning significantly influences convective base heating. Turbulence models and external nozzle wall thermal boundary layer profiles show less sensitivity to base heating characteristics. Base heating rates are validated for the highest fidelity solutions which show an agreement within +/-10% with respect to test data.
Accuracy of nursing diagnosis "readiness for enhanced hope" in patients with chronic kidney disease.
Silva, Renan Alves; Melo, Geórgia Alcântara Alencar; Caetano, Joselany Áfio; Lopes, Marcos Venícios Oliveira; Butcher, Howard Karl; Silva, Viviane Martins da
2017-07-06
To analyse the accuracy of the nursing diagnosis readiness for enhanced hope in patients with chronic kidney disease. This is a cross-sectional study with 62 patients in the haemodialysis clinic conducted from August to November 2015. The Hearth Hope Scale was used to create definitions of the defining characteristics of the North American Nursing Diagnosis Association International. We analysed the measures of sensitivity, specificity, predictive value, likelihood ratio, and odds ratio of the defining characteristics of the diagnosis. Of the characteristics, 82.22% presented the diagnosis. The defining characteristics "Expresses the desire to enhance congruency of expectations with desires" and "Expresses the desire to enhance problem solving to meet goals" increased the chance of having the diagnosis by eleven and five, respectively. The characteristics, "Expresses desire to enhance congruency of expectations with desires" and "Expresses desire to enhance problem solving to meet goals" had good accuracy measures.
Evangelista, Laura; Cuocolo, Alberto; Pace, Leonardo; Mansi, Luigi; Del Vecchio, Silvana; Miletto, Paolo; Sanfilippo, Silvia; Pellegrino, Sara; Guerra, Luca; Pepe, Giovanna; Peluso, Giuseppina; Salvatore, Marco; Galicchio, Rosj; Zuffante, Michele; Annunziata, Salvatore; Farsad, Mohsen; Chiaravalloti, Agostino; Spadafora, Marco
2018-05-07
The aim of this study was to determine the performance of 18 F-FDG-PET/CT in patients with solitary pulmonary nodule (SPN), stratifying the risk according to the likelihood of pulmonary malignancy. FDG-PET/CT of 502 patients, stratified for pre-test cancer risk, were retrospectively analyzed. FDG uptake in SPN was assessed by a 4-point scoring system and semiquantitative analysis using the ratio between SUVmax in SPN and SUVmean in mediastinal blood pool (BP) and between SUVmax in SPN and SUVmean in liver (L). Histopathology and/or follow-up data were used as standard of reference. SPN was malignant in 180 (36%) patients, benign in 175 (35%), and indeterminate in 147 (29%). The 355 patients with a definitive SPN nature (malignant or benign) were considered for the analysis. Considering FDG uptake ≥ 2, sensitivity, specificity, positive (PPV) and negative (NPV) predictive values, and accuracy were 85.6%, 85.7%, 86%, 85.2%, and 85.6% respectively. Sensitivity and PPV were higher (P < 0.05) in intermediate and high-risk patients, while specificity and NPV were higher (P < 0.05) in low-risk patients. On receiver operating characteristic curve analysis, the cut-offs for better discrimination between benign and malignant SPN were 1.56 (sensitivity 81% and specificity 87%) and 1.12 (sensitivity 81% and specificity 86%) for SUVmax/SUVmeanBP and SUVmax/SUVmeanL respectively. In intermediate and high-risk patients, including the SUVmax/SUVmeanBP, the specificity shifted from 85% and 50% to 100%. Visual FDG-PET/CT has an acceptable performance in patients with SPN, but accuracy improves when SUVratios are considered, particularly in patients with intermediate and high risk of malignancy.
Huy, Nguyen Tien; Thao, Nguyen Thanh Hong; Tuan, Nguyen Anh; Khiem, Nguyen Tuan; Moore, Christopher C.; Thi Ngoc Diep, Doan; Hirayama, Kenji
2012-01-01
Background and Purpose Successful outcomes from bacterial meningitis require rapid antibiotic treatment; however, unnecessary treatment of viral meningitis may lead to increased toxicities and expense. Thus, improved diagnostics are required to maximize treatment and minimize side effects and cost. Thirteen clinical decision rules have been reported to identify bacterial from viral meningitis. However, few rules have been tested and compared in a single study, while several rules are yet to be tested by independent researchers or in pediatric populations. Thus, simultaneous test and comparison of these rules are required to enable clinicians to select an optimal diagnostic rule for bacterial meningitis in settings and populations similar to ours. Methods A retrospective cross-sectional study was conducted at the Infectious Department of Pediatric Hospital Number 1, Ho Chi Minh City, Vietnam. The performance of the clinical rules was evaluated by area under a receiver operating characteristic curve (ROC-AUC) using the method of DeLong and McNemar test for specificity comparison. Results Our study included 129 patients, of whom 80 had bacterial meningitis and 49 had presumed viral meningitis. Spanos's rule had the highest AUC at 0.938 but was not significantly greater than other rules. No rule provided 100% sensitivity with a specificity higher than 50%. Based on our calculation of theoretical sensitivity and specificity, we suggest that a perfect rule requires at least four independent variables that posses both sensitivity and specificity higher than 85–90%. Conclusions No clinical decision rules provided an acceptable specificity (>50%) with 100% sensitivity when applying our data set in children. More studies in Vietnam and developing countries are required to develop and/or validate clinical rules and more very good biomarkers are required to develop such a perfect rule. PMID:23209715
McKown, Andrew C; Brown, Ryan M; Ware, Lorraine B; Wanderer, Jonathan P
2017-01-01
Automated electronic sniffers may be useful for early detection of acute respiratory distress syndrome (ARDS) for institution of treatment or clinical trial screening. In a prospective cohort of 2929 critically ill patients, we retrospectively applied published sniffer algorithms for automated detection of acute lung injury to assess their utility in diagnosis of ARDS in the first 4 ICU days. Radiographic full-text reports were searched for "edema" OR ("bilateral" AND "infiltrate") and a more detailed algorithm for descriptions consistent with ARDS. Patients were flagged as possible ARDS if a radiograph met search criteria and had a PaO 2 /FiO 2 or SpO 2 /FiO 2 of 300 or 315, respectively. Test characteristics of the electronic sniffers and clinical suspicion of ARDS were compared to a gold standard of 2-physician adjudicated ARDS. Thirty percent of 2841 patients included in the analysis had gold standard diagnosis of ARDS. The simpler algorithm had sensitivity for ARDS of 78.9%, specificity of 52%, positive predictive value (PPV) of 41%, and negative predictive value (NPV) of 85.3% over the 4-day study period. The more detailed algorithm had sensitivity of 88.2%, specificity of 55.4%, PPV of 45.6%, and NPV of 91.7%. Both algorithms were more sensitive but less specific than clinician suspicion, which had sensitivity of 40.7%, specificity of 94.8%, PPV of 78.2%, and NPV of 77.7%. Published electronic sniffer algorithms for ARDS may be useful automated screening tools for ARDS and improve on clinical recognition, but they are limited to screening rather than diagnosis because their specificity is poor.
Huy, Nguyen Tien; Thao, Nguyen Thanh Hong; Tuan, Nguyen Anh; Khiem, Nguyen Tuan; Moore, Christopher C; Thi Ngoc Diep, Doan; Hirayama, Kenji
2012-01-01
Successful outcomes from bacterial meningitis require rapid antibiotic treatment; however, unnecessary treatment of viral meningitis may lead to increased toxicities and expense. Thus, improved diagnostics are required to maximize treatment and minimize side effects and cost. Thirteen clinical decision rules have been reported to identify bacterial from viral meningitis. However, few rules have been tested and compared in a single study, while several rules are yet to be tested by independent researchers or in pediatric populations. Thus, simultaneous test and comparison of these rules are required to enable clinicians to select an optimal diagnostic rule for bacterial meningitis in settings and populations similar to ours. A retrospective cross-sectional study was conducted at the Infectious Department of Pediatric Hospital Number 1, Ho Chi Minh City, Vietnam. The performance of the clinical rules was evaluated by area under a receiver operating characteristic curve (ROC-AUC) using the method of DeLong and McNemar test for specificity comparison. Our study included 129 patients, of whom 80 had bacterial meningitis and 49 had presumed viral meningitis. Spanos's rule had the highest AUC at 0.938 but was not significantly greater than other rules. No rule provided 100% sensitivity with a specificity higher than 50%. Based on our calculation of theoretical sensitivity and specificity, we suggest that a perfect rule requires at least four independent variables that posses both sensitivity and specificity higher than 85-90%. No clinical decision rules provided an acceptable specificity (>50%) with 100% sensitivity when applying our data set in children. More studies in Vietnam and developing countries are required to develop and/or validate clinical rules and more very good biomarkers are required to develop such a perfect rule.
Isolation and characterization of Escherichia coli pili from diverse clinical sources.
Salit, I E; Vavougios, J; Hofmann, T
1983-11-01
Bacteria which attach to different mucous membranes should have differing specificities of adherence in vitro. Human Escherichia coli isolates from blood and urine (pathogens) and from stool and throat (commensals) were characterized as to the patterns of hemagglutination (HA), as well as the structure and function of their pili. Bacterial HA was done in microtiter plates and on slides after bacterial growth in broth or agar. Human erythrocytes were agglutinated by 95% of the pathogens and 65 to 70% of the commensals grown in broth or agar. Mannose-resistant HA was characteristically caused by pathogens, and commensals characteristically caused mannose-sensitive HA of guinea pig cells. Strains often had both mannose-resistant and mannose-sensitive reactions, or even a mannose-paradoxical reaction. Pathogens more often caused HA, but titers were lower than those for commensals. Slide HA was less sensitive than the microtiter method. All isolates were piliated. Commensals also had more pili than pathogens when grown in broth (117.8 versus 38.3 pili per bacterium), but pathogens had more pili after growth on agar (32.1 versus 8.1 pili per bacterium). Isolates causing high-titer HA had large numbers of pili (greater than 85 pili per bacterium), but some well-piliated strains were non-hemagglutinating. Pili were purified from seven E. coli strains from different sites of isolation and with different erythrocyte-binding specificity. Pili usually migrated as a single band on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. However, more than one type of pilus could be copurified from some strains since there were two or more bands after separation in octyl-glucoside and two different amino terminal sequences. Protein sequencing was done on five different pili: four resembled type 1 pili and one was a P fimbria. The type 1-like pili (strains 2239 and 9353) had an initial variable sequence of 1 to 5 residues, followed by a common region of 21 residues. The P fimbria (strain 7714) had different erythrocyte-binding specificity but was still 27% homologous with 2239 and 9353. E. coli strains from different body sites have characteristic attachments to erythrocytes. Pili derived from these different sources may also have different binding specificity, but they are similar in primary structure.
Isolation and characterization of Escherichia coli pili from diverse clinical sources.
Salit, I E; Vavougios, J; Hofmann, T
1983-01-01
Bacteria which attach to different mucous membranes should have differing specificities of adherence in vitro. Human Escherichia coli isolates from blood and urine (pathogens) and from stool and throat (commensals) were characterized as to the patterns of hemagglutination (HA), as well as the structure and function of their pili. Bacterial HA was done in microtiter plates and on slides after bacterial growth in broth or agar. Human erythrocytes were agglutinated by 95% of the pathogens and 65 to 70% of the commensals grown in broth or agar. Mannose-resistant HA was characteristically caused by pathogens, and commensals characteristically caused mannose-sensitive HA of guinea pig cells. Strains often had both mannose-resistant and mannose-sensitive reactions, or even a mannose-paradoxical reaction. Pathogens more often caused HA, but titers were lower than those for commensals. Slide HA was less sensitive than the microtiter method. All isolates were piliated. Commensals also had more pili than pathogens when grown in broth (117.8 versus 38.3 pili per bacterium), but pathogens had more pili after growth on agar (32.1 versus 8.1 pili per bacterium). Isolates causing high-titer HA had large numbers of pili (greater than 85 pili per bacterium), but some well-piliated strains were non-hemagglutinating. Pili were purified from seven E. coli strains from different sites of isolation and with different erythrocyte-binding specificity. Pili usually migrated as a single band on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. However, more than one type of pilus could be copurified from some strains since there were two or more bands after separation in octyl-glucoside and two different amino terminal sequences. Protein sequencing was done on five different pili: four resembled type 1 pili and one was a P fimbria. The type 1-like pili (strains 2239 and 9353) had an initial variable sequence of 1 to 5 residues, followed by a common region of 21 residues. The P fimbria (strain 7714) had different erythrocyte-binding specificity but was still 27% homologous with 2239 and 9353. E. coli strains from different body sites have characteristic attachments to erythrocytes. Pili derived from these different sources may also have different binding specificity, but they are similar in primary structure. Images PMID:6139339
Matthew Fields, J; Davis, Joshua; Alsup, Carl; Bates, Amanda; Au, Arthur; Adhikari, Srikar; Farrell, Isaac
2017-09-01
The use of ultrasonography (US) to diagnose appendicitis is well established. More recently, point-of-care ultrasonography (POCUS) has also been studied for the diagnosis of appendicitis, which may also prove a valuable diagnostic tool. The purpose of this study was through systematic review and meta-analysis to identify the test characteristics of POCUS, specifically US performed by a nonradiologist physician, in accurately diagnosing acute appendicitis in patients of any age. We conducted a thorough and systematic literature search of English language articles published on point-of-care, physician-performed transabdominal US used for the diagnosis of acute appendicitis from 1980 to May, 2015 using OVID MEDLINE In-Process & Other Non-indexed Citations and Scopus. Studies were selected and subsequently independently abstracted by two trained reviewers. A random-effects pooled analysis was used to construct a hierarchical summary receiver operator characteristic curve, and a meta-regression was performed. Quality of studies was assessed using the QUADAS-2 tool. Our search yielded 5,792 unique studies and we included 21 of these in our final review. Prevalence of disease in this study was 29.8%, (range = 6.4%-75.4%). The sensitivity and specificity for POCUS in diagnosing appendicitis were 91% (95% confidence interval [CI] = 83%-96%) and 97% (95% CI = 91%-99%), respectively. The positive and negative predictive values were 91 and 94%, respectively. Studies performed by emergency physicians had slightly lower test characteristics (sensitivity = 80%, specificity = 92%). There was significant heterogeneity between studies (I 2 = 99%, 95% CI = 99%-100%) and the quality of the reported studies was moderate, mostly due to unclear reporting of blinding of physicians and timing of scanning and patient enrollment. Several of the studies were performed by a single operator, and the education and training of the operators were variably reported. Point-of-care US has relatively high sensitivity and specificity for diagnosing acute appendicitis, although the data presented are limited by the quality of the original studies and large CIs. In the hands of an experienced operator, POCUS is an appropriate initial imaging modality for diagnosing appendicitis. Based on our results, it is premature to utilize POCUS as a stand-alone test or to rule out appendicitis. © 2017 by the Society for Academic Emergency Medicine.
Kumar, Manish; Srivastava, Shilpee; Singh, Seram Anil; Das, Anup Kumar; Das, Ganesh Chandra; Dhar, Bishal; Ghosh, Sankar Kumar; Mondal, Rosy
2017-10-01
Head and neck squamous cell carcinoma is the most commonly diagnosed cancer worldwide. The lifestyle, food habits, and customary practices manifest the Northeast Indian population toward higher susceptibility to develop head and neck squamous cell carcinoma. Here, we have investigated the association of smoke and smokeless tobacco, and alcohol with copy number variation of cell-free mitochondrial DNA and cell-free nuclear DNA in cases and controls. Cell-free DNA from plasma was isolated from 50 head and neck squamous cell carcinoma cases and 50 controls with informed written consent using QIAamp Circulating Nucleic Acid Kit. Real-time polymerase chain reaction was done for copy number variation in cell-free mitochondrial DNA and cell-free nuclear DNA. Receiver operating characteristic curve analysis was performed to evaluate the diagnostic application between the two study groups using clinicopathological parameters. The levels of cell-free nuclear DNA and cell-free mitochondrial DNA of cases in association with smoke and smokeless tobacco, alcohol with smoking (p < 0.05) were significantly higher (p < 0.01 and p < 0.001, respectively) than controls. Using receiver operating characteristic curve analysis between head and neck squamous cell carcinoma cases and controls, we distinguished cell-free mitochondrial DNA (cutoff: 19.84 raw Ct; sensitivity: 84%; specificity: 100%; p < 0.001) and cell-free nuclear DNA (cutoff: 463,282 genomic equivalent/mL; sensitivity: 53%; specificity: 87%; p < 0.001). The copy number variation in cases (cell-free nuclear DNA: 5451.66 genomic equivalent/mL and cell-free mitochondrial DNA: 29,103,476.15 genomic equivalent/mL) and controls (cell-free nuclear DNA: 1650.9 genomic equivalent/mL and cell-free mitochondrial DNA: 9,189,312.54 genomic equivalent/mL), respectively. Our result indicates that the cell-free mitochondrial DNA content is highly associated with smoke and smokeless tobacco, betel quid chewing, and alcohol which shows greater promises, holding the key characteristics of diagnostic biomarkers, that is, minimal invasiveness, high specificity, and sensitivity.
Liu, Jia; Li, Wenwu; Huang, Yong; Mu, Dianbin; Yu, Haiying; Li, Shanshan
2015-08-01
The aim of this study was to retrospectively investigate the multi-detector computed tomography (MDCT) features of preinvasive lesions and minimally invasive adenocarcinoma (MIA) appearing as ground-glass nodules (GGNs), and to analyze their significance in differential diagnosis. The pathological data and MDCT images of 111 GGNs in 93 patients were reviewed and analyzed retrospectively, to identify the differentiating CT features between preinvasive lesions and MIA and to evaluate their differentiating accuracy. In the 93 patients included in the study, there were 27 cases with preinvasive lesions (38 GGNs) and 66 cases with MIA (73 GGNs). No statistically significant difference was observed in terms of the gender, age and number of lesions between the two groups. There were significant differences (P<0.05) in the size of lesion, size of solid portion, content of solid portion, and morphological characteristics of the lesion edge between preinvasive lesions and MIA. ROC curve analysis showed that the optimal cut-off value of lesion size for differentiating preinvasive lesions from MIA was 13.0 mm (sensitivity, 83.0%; specificity, 80.0%), and that of solid portion size was 2.0 mm (sensitivity, 90.0%; specificity, 97.0%) and that of solid proportion was 12.0% (sensitivity, 88.0%; specificity, 97.0%). The analysis of CT morphological features showed that there were significant differences in the terms of lesion nature (pGGO, mGGO), presence or absence of lobulated sign and spiculated sign (P<0.05) between preinvasive lesions and MIA, but there were no significant differences in terms of the lesion edge, the presence or absence of vacuole sign, bubble lucency and pleural retraction (P>0.05). Preinvasive lesions can be accurately distinguished from MIA by the size of lesion, size of solid portion,solid proportion and morphological characteristics of the lesion edge. The size of lesion, size of solid portion, content of solid proportion and morphological characteristics of the lesion edge are of significance in the differential diagnosis of preinvasive lesions and minimally invasive adenocarcinoma of the lung.
Zhao, Yang; Ren, Wei; Zhong, Ting; Zhang, Shuang; Huang, Dan; Guo, Yang; Yao, Xin; Wang, Chao; Zhang, Wei-Qiang; Zhang, Xuan; Zhang, Qiang
2016-01-28
The pH environment in gliomas is acidic. Therefore, in the present research, we selected our previously reported tumor-specific pH-responsive peptide H7K(R2)2 as a targeting ligand, which could respond to the acidic pH environment in gliomas, possessing CPP characteristics. The pH-sensitive liposomes were selected as carriers which could also respond to the acidic pH environment in gliomas triggering encapsulated drug release from these pH-sensitive liposomes. The H7K(R2)2-modified pH-sensitive liposomes containing doxorubicin (DOX-PSL-H7K(R2)2) were designed and prepared in order to evaluate their potential targeting of glioma tumor cells and their anti-tumor activity in mice with glioma tumor cells. DOX-PSL-H7K(R2)2 was prepared by the thin-film hydration method followed by remote loading using an ammonium sulfate gradient method. The in vitro release of DOX from pH-sensitive liposomes was tested and the in vitro targeting characteristics of H7K(R2)2-modified liposomes regarding C6 (rat C6 glioma cells) and U87-MG (human glioblastoma cells) were evaluated. The in vivo anti-tumor activity of DOX-PSL-H7K(R2)2 was also investigated in C6 tumor-bearing mice and in U87-MG orthotopic tumor-bearing nude mice. A specific targeting effect triggered by an acidic pH was observed in our in vitro experiments in C6 and U87-MG glioma cells. The pH-triggered DOX release from the pH-sensitive liposomes under acidic conditions was also confirmed in our in vitro experiment. Anti-tumor activity of DOX-PSL-H7K(R2)2 was found in C6 tumor-bearing mice and U87-MG orthotopic tumor-bearing nude mice in in vivo experiments. The antiangiogenic activity of DOX-PSL-H7K(R2)2 was confirmed in C6 tumor-bearing mice in the in vivo experiment. These H7K(R2)2-modified pH-sensitive liposomes containing anti-tumor drugs developed in this study are a promising delivery system involving the response stimuli at the acidic pH in the glioma tumor microenvironment and are suitable for anti-tumor therapy. Copyright © 2015 Elsevier B.V. All rights reserved.
Sensitivity of Hyperdense Basilar Artery Sign on Non-Enhanced Computed Tomography
Ernst, Marielle; Romero, Javier M.; Buhk, Jan-Hendrik; Cheng, Bastian; Herrmann, Jochen; Fiehler, Jens; Groth, Michael
2015-01-01
Purpose The hyperdense basilar artery sign (HBAS) is an indicator of vessel occlusion on non contrast-enhanced computer tomography (NECT) in acute stroke patients. Since basilar artery occlusion (BAO) is associated with a high mortality and morbidity, its early detection is of great clinical value. We sought to analyze the influence of density measurement as well as a normalized ratio of Hounsfield unit/hematocrit (HU/Hct) ratio on the detection of BAO on NECT in patients with suspected BAO. Materials and Methods 102 patients with clinically suspected BAO were examined with NECT followed immediately by Multidetector computed tomography Angiography. Two observers independently analyzed the images regarding the presence or absence of HBAS on NECT and performed HU measurements in the basilar artery. Receiver operating characteristic curve analysis was performed to determine the optimal density threshold for BAO using attenuation measurements or HU/Hct ratio. Results Sensitivity of visual detection of the HBAS on NECT was relatively low 81% (95%-CI, 54–95%) while specificity was high 91% (95%-CI, 82–96%). The highest sensitivity was achieved by the combination of visual assessment and additional quantitative attenuation measurements applying a cut-off value of 46.5 HU with 94% sensitivity and 81% specificity for BAO. A HU/Hct ratio >1.32 revealed sensitivity of 88% (95%-CI, 60–98%) and specificity of 84% (95%-CI, 74–90%). Conclusion In patients with clinically suspected acute BAO the combination of visual assessment and additional attenuation measurement with a cut-off value of 46.5 HU is a reliable approach with high sensitivity in the detection of BAO on NECT. PMID:26479718
Mangueira, Suzana de Oliveira; Lopes, Marcos Venícios de Oliveira
2016-10-01
To evaluate the clinical validity indicators for the nursing diagnosis of dysfunctional family processes related to alcohol abuse. Alcoholism is a chronic disease that negatively affects family relationships. Studies on the nursing diagnosis of dysfunctional family processes are scarce in the literature. This diagnosis is currently composed of 115 defining characteristics, hindering their use in practice and highlighting the need for clinical validation. This was a diagnostic accuracy study. A sample of 110 alcoholics admitted to a reference centre for alcohol treatment was assessed during the second half of 2013 for the presence or absence of the defining characteristics of the diagnosis. Operational definitions were created for each defining characteristic based on concept analysis and experts evaluated the content of these definitions. Diagnostic accuracy measures were calculated from latent class models with random effects. All 89 clinical indicators were found in the sample and a set of 24 clinical indicators was identified as clinically valid for a diagnostic screening for family dysfunction from the report of alcoholics. Main clinical indicators with high specificity included sexual abuse, disturbance in academic performance in children and manipulation. The main indicators that showed high sensitivity values were distress, loss, anxiety, low self-esteem, confusion, embarrassment, insecurity, anger, loneliness, deterioration in family relationships and disturbance in family dynamics. Eighteen clinical indicators showed a high capacity for diagnostic screening for alcoholics (high sensitivity) and six indicators can be used for confirmatory diagnosis (high specificity). © 2016 John Wiley & Sons Ltd.
Guillem, Maria S; Climent, Andreu M; Millet, José; Berne, Paola; Ramos, Rafael; Brugada, Josep; Brugada, Ramon
2016-05-01
The diagnosis of Brugada syndrome based on the ECG is hampered by the dynamic nature of its ECG manifestations. Brugada syndrome patients are only 25% likely to present a type 1 ECG. The objective of this study is to provide an ECG diagnostic criterion for Brugada syndrome patients that can be applied consistently even in the absence of a type 1 ECG. We recorded 67-lead body surface potential maps from 94 Brugada syndrome patients and 82 controls (including right bundle branch block patients and healthy individuals). The spatial propagation direction during the last r' wave and the slope at the end of the QRS complex were measured and compared between patients groups. Receiver-operating characteristic curves were constructed for half of the database to identify optimal cutoff values; sensitivity and specificity for these cutoff values were measured in the other half of the database. A spontaneous type 1 ECG was present in only 30% of BrS patients. An orientation in the sagittal plane < 101º during the last r' wave and a descending slope < 9.65 mV/s enables the diagnosis of the syndrome with a sensitivity of 69% and a specificity of 97% in non-type 1 Brugada syndrome patients. Spatiotemporal characteristics of surface ECG recordings can enable a robust identification of BrS even without the presence of a type 1 ECG. © 2016 Wiley Periodicals, Inc.
Dusing, Reginald W.; Peng, Warner; Lai, Sue-Min; Grado, Gordon L.; Holzbeierlein, Jeffrey M.; Thrasher, J. Brantley; Hill, Jacqueline; Van Veldhuizen, Peter J.
2014-01-01
Purpose The aim of this study was to identify which patient characteristics are associated with the highest likelihood of positive findings on 11C-acetate PET/computed tomography attenuation correction (CTAC) (PET/CTAC) scan when imaging for recurrent prostate cancer. Methods From 2007 to 2011, 250 11C-acetate PET/CTAC scans were performed at a single institution on patients with prostate cancer recurrence after surgery, brachytherapy, or external beam radiation. Of these patients, 120 met our inclusion criteria. Logistic regression analysis was used to examine the relationship between predictability of positive findings and patients’ characteristics, such as prostate-specific antigen (PSA) level at the time of scan, PSA kinetics, Gleason score, staging, and type of treatment before scan. Results In total, 68.3% of the 120 11C-acetate PET/CTAC scans were positive. The percentage of positive scans and PSA at the time of scanning and PSA velocity (PSAV) had positive correlations. The putative sensitivity and specificity were 86.6% and 65.8%, respectively, when a PSA level greater than 1.24 ng/mL was used as the threshold for scanning. The putative sensitivity and specificity were 74% and 75%, respectively, when a PSAV level greater than 1.32 ng/mL/y was used as the threshold. No significant associations were found between scan positivity and age, PSA doubling time, Gleason score, staging, or type of treatment before scanning. Conclusions This retrospective study suggests that threshold models of PSA greater than 1.24 ng/mL or PSAV greater than 1.32 ng/mL per year are independent predictors of positive findings in 11C-acetate PET/CTAC imaging of recurrent prostate cancer. PMID:25036021
Screening tests: a review with examples
Niebo, Ron; Utell, Mark J.
2014-01-01
Screening tests are widely used in medicine to assess the likelihood that members of a defined population have a particular disease. This article presents an overview of such tests including the definitions of key technical (sensitivity and specificity) and population characteristics necessary to assess the benefits and limitations of such tests. Several examples are used to illustrate calculations, including the characteristics of low dose computed tomography as a lung cancer screen, choice of an optimal PSA cutoff and selection of the population to undergo mammography. The importance of careful consideration of the consequences of both false positives and negatives is highlighted. Receiver operating characteristic curves are explained as is the need to carefully select the population group to be tested. PMID:25264934
de Jong, Martijn G; Pieters, Rik; Stremersch, Stefan
2012-09-01
Answers to sensitive questions are prone to social desirability bias. If not properly addressed, the validity of the research can be suspect. This article presents multigroup item randomized response theory (MIRRT) to measure self-reported sensitive topics across cultures. The method was specifically developed to reduce social desirability bias by making an a priori change in the design of the survey. The change involves the use of a randomization device (e.g., a die) that preserves participants' privacy at the item level. In cases where multiple items measure a higher level theoretical construct, the researcher could still make inferences at the individual level. The method can correct for under- and overreporting, even if both occur in a sample of individuals or across nations. We present and illustrate MIRRT in a nontechnical manner, provide WinBugs software code so that researchers can directly implement it, and present 2 cross-national studies in which it was applied. The first study compared nonstudent samples from 2 countries (total n = 927) on permissive sexual attitudes and risky sexual behavior and related these to individual-level characteristics such as the Big Five personality traits. The second study compared nonstudent samples from 17 countries (total n = 6,195) on risky sexual behavior and related these to individual-level characteristics, such as gender and age, and to country-level characteristics, such as sex ratio.
Sabbisetti, Venkata S.; Francis, Ben; Jorgensen, Andrea L.; Craig, Darren G.N.; Simpson, Kenneth J.; Bonventre, Joseph V.; Park, B. Kevin; Dear, James W.
2015-01-01
Acute kidney injury in the context of acetaminophen (APAP; paracetamol)‐induced liver injury is an important predictor of the requirement for urgent liver transplantation (LT) to avoid death. However, the prognostic biomarker used to report kidney dysfunction (serum creatinine concentration) has suboptimal sensitivity and specificity. Kidney injury molecule 1 (KIM‐1) can be quantified in plasma as a sensitive and specific biomarker of kidney injury in both clinical and preclinical studies. Therefore, plasma KIM‐1 has potential as a sensitive prognostic biomarker of patient outcome post‐APAP overdose. In a cohort of APAP overdose patients (N = 74) with and without established liver injury, we quantified plasma KIM‐1 by immunoassay on the first day of admission to a LT unit and assessed its diagnostic performance to predict outcome compared with serum creatinine concentration. Day 1 plasma KIM‐1 was significantly elevated in patients that died or required LT, compared to spontaneous survivors (1,182 ± 251 vs. 214 ± 45 pg/mL; P < 0.005). Receiver operator characteristic analysis demonstrated the superiority of KIM‐1 (area under the curve [AUC]: 0.87; 95% confidence interval [CI]: 0.78‐0.95; 0.56 sensitivity at 0.95 specificity), compared with serum creatinine (AUC, 0.76; 95% CI: 0.64‐0.87; 0.08 sensitivity at 0.95 specificity) and other current prognostic indicators, when measured on the first day of enrollment into the study. Furthermore, KIM‐1 was found to be a statistically significant independent predictor of outcome at the 5% level (P < 0.0386) in a multivariable logistic regression model that considered all measured factors (pseudo‐R^2 = 0.895). Conclusion: Early measurement of plasma KIM‐1 represents a more sensitive predictor of patient outcome than serum creatinine concentration post‐APAP overdose. With further development, plasma KIM‐1 could significantly improve prognostic stratification. (Hepatology 2015;62:591–599 PMID:25891479
Accommodative Lag by Autorefraction and Two Dynamic Retinoscopy Methods
2008-01-01
Purpose To evaluate two clinical procedures, MEM and Nott retinoscopy, for detecting accommodative lags 1.00 diopter (D) or greater in children as identified by an open-field autorefractor. Methods 168 children 8 to <12 years old with low myopia, normal visual acuity, and no strabismus participated as part of an ancillary study within the screening process for a randomized trial. Accommodative response to a 3.00 D demand was first assessed by MEM and Nott retinoscopy, viewing binocularly with spherocylindrical refractive error corrected, with testing order randomized and each performed by a different masked examiner. The response was then determined viewing monocularly with spherical equivalent refractive error corrected, using an open-field autorefractor, which was the gold standard used for eligibility for the clinical trial. Sensitivity and specificity for accommodative lags of 1.00 D or more were calculated for each retinoscopy method compared to the autorefractor. Results 116 (69%) of the 168 children had accommodative lag of 1.00 D or more by autorefraction. MEM identified 66 children identified by autorefraction for a sensitivity of 57% (95% CI = 47% to 66%) and a specificity of 63% (95% CI = 49% to 76%). Nott retinoscopy identified 35 children for a sensitivity of 30% (95% CI = 22% to 39%) and a specificity of 81% (95% CI = 67% to 90%). Analysis of receiver operating characteristic (ROC) curves constructed for MEM and for Nott retinoscopy failed to reveal alternate cut points that would improve the combination of sensitivity and specificity for identifying accommodative lag ≥ 1.00 D as defined by autorefraction. Conclusions Neither MEM nor Nott retinoscopy provided adequate sensitivity and specificity to identify myopic children with accommodative lag ≥ 1.00 D as determined by autorefraction. A variety of methodological differences between the techniques may contribute to the modest to poor agreement. PMID:19214130
Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi
2017-04-01
To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P < 0.001 and P = 0.001, respectively). With all b-value combinations, the entropy of ADC was significantly higher in pheochromocytomas than in adrenal adenomas (all P ≤ 0.001), and showed the highest area under the ROC curve among the ADC histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.
Bertran, E A; Berlie, H D; Taylor, A; Divine, G; Jaber, L A
2017-02-01
To examine differences in the performance of HbA 1c for diagnosing diabetes in Arabs compared with Europeans. The PubMed, Embase and Cochrane library databases were searched for records published between 1998 and 2015. Estimates of sensitivity, specificity and log diagnostic odds ratios for an HbA 1c cut-point of 48 mmol/mol (6.5%) were compared between Arabs and Europeans, using a bivariate linear mixed-model approach. For studies reporting multiple cut-points, population-specific summary receiver operating characteristic (SROC) curves were constructed. In addition, sensitivity, specificity and Youden Index were estimated for strata defined by HbA 1c cut-point and population type. Database searches yielded 1912 unique records; 618 full-text articles were reviewed. Fourteen studies met the inclusion criteria; hand-searching yielded three additional eligible studies. Three Arab (N = 2880) and 16 European populations (N = 49 127) were included in the analysis. Summary sensitivity and specificity for a HbA 1c cut-point of 48 mmol/mol (6.5%) in both populations were 42% (33-51%), and 97% (95-98%). There was no difference in area under SROC curves between Arab and European populations (0.844 vs. 0.847; P = 0.867), suggesting no difference in HbA 1c diagnostic accuracy between populations. Multiple cut-point summary estimates stratified by population suggest that Arabs have lower sensitivity and higher specificity at a HbA 1c cut-point of 44 mmol/mol (6.2%) compared with European populations. Estimates also suggest similar test performance at cut-points of 44 mmol/mol (6.2%) and 48 mmol/mol (6.5%) for Arabs. Given the low sensitivity of HbA 1c in the high-risk Arab American population, we recommend a combination of glucose-based and HbA 1c testing to ensure an accurate and timely diagnosis of diabetes. © 2016 Diabetes UK.
Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara
2015-01-01
Background: The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. Materials and Methods: In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. Results: A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Conclusions: Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta. PMID:25709996
Naghshineh, Elham; Khorvash, Elahe; Kamali, Sara
2015-01-01
The aim of the present study was to comparison between cell-free placental messenger ribonucleic acid (mRNA) and Doppler ultrasound for the prediction of placental invasion in women with placenta accreta. In this cross-sectional study, 50 pregnant women at risk for placenta accreta underwent color Doppler and assessment of cell-free placental mRNA. Real-time reverse-transcription polymerase chain reaction was used for measurement of cell-free placental mRNA in maternal plasma. Based on the findings at cesarean delivery and histological examination, patients were divided into two groups of women with and without placenta accrete. To compare of the mean of mRNA levels between the two groups we used independent t-test and to compare of the mean of age and gestational age at sonography we used Mann-Whitney test. For determination of sensitivity and specificity and the cut-off point of mRNA levels we used the receiver operating characteristic curve. A total of 50 women with a mean age of 30.24 ± 4.905 years entered the study and 12 (24%) patients were diagnosed with placenta accreta. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of Doppler ultrasound were 83.3%, 78.9%, 56% and 94%, respectively. Results of our study showed if we consider a cut-off point equal to 3.325, with sensitivity and specificity of 0.917 and 0.789, respectively and the sensitivity, specificity, PPV and NPV of mRNA with were cut-off point of 3.325 were 91.7%, 78.9%, 57.9% and 96.8%, respectively. Cell-free mRNA is an acceptable, easy made, functional test with sensitivity, specificity, PPV and NPV more than Doppler ultrasound for diagnosis and prediction of incidence of placenta accrete and we recommend the use of cell-free mRNA test for diagnosis of placenta accreta.
Froud, Robert; Abel, Gary
2014-01-01
Background Receiver Operator Characteristic (ROC) curves are being used to identify Minimally Important Change (MIC) thresholds on scales that measure a change in health status. In quasi-continuous patient reported outcome measures, such as those that measure changes in chronic diseases with variable clinical trajectories, sensitivity and specificity are often valued equally. Notwithstanding methodologists agreeing that these should be valued equally, different approaches have been taken to estimating MIC thresholds using ROC curves. Aims and objectives We aimed to compare the different approaches used with a new approach, exploring the extent to which the methods choose different thresholds, and considering the effect of differences on conclusions in responder analyses. Methods Using graphical methods, hypothetical data, and data from a large randomised controlled trial of manual therapy for low back pain, we compared two existing approaches with a new approach that is based on the addition of the sums of squares of 1-sensitivity and 1-specificity. Results There can be divergence in the thresholds chosen by different estimators. The cut-point selected by different estimators is dependent on the relationship between the cut-points in ROC space and the different contours described by the estimators. In particular, asymmetry and the number of possible cut-points affects threshold selection. Conclusion Choice of MIC estimator is important. Different methods for choosing cut-points can lead to materially different MIC thresholds and thus affect results of responder analyses and trial conclusions. An estimator based on the smallest sum of squares of 1-sensitivity and 1-specificity is preferable when sensitivity and specificity are valued equally. Unlike other methods currently in use, the cut-point chosen by the sum of squares method always and efficiently chooses the cut-point closest to the top-left corner of ROC space, regardless of the shape of the ROC curve. PMID:25474472
Esteghamati, Alireza; Ashraf, Haleh; Khalilzadeh, Omid; Zandieh, Ali; Nakhjavani, Manouchehr; Rashidi, Armin; Haghazali, Mehrdad; Asgari, Fereshteh
2010-04-07
We have recently determined the optimal cut-off of the homeostatic model assessment of insulin resistance for the diagnosis of insulin resistance (IR) and metabolic syndrome (MetS) in non-diabetic residents of Tehran, the capital of Iran. The aim of the present study is to establish the optimal cut-off at the national level in the Iranian population with and without diabetes. Data of the third National Surveillance of Risk Factors of Non-Communicable Diseases, available for 3,071 adult Iranian individuals aging 25-64 years were analyzed. MetS was defined according to the Adult Treatment Panel III (ATPIII) and International Diabetes Federation (IDF) criteria. HOMA-IR cut-offs from the 50th to the 95th percentile were calculated and sensitivity, specificity, and positive likelihood ratio for MetS diagnosis were determined. The receiver operating characteristic (ROC) curves of HOMA-IR for MetS diagnosis were depicted, and the optimal cut-offs were determined by two different methods: Youden index, and the shortest distance from the top left corner of the curve. The area under the curve (AUC) (95%CI) was 0.650 (0.631-0.670) for IDF-defined MetS and 0.683 (0.664-0.703) with the ATPIII definition. The optimal HOMA-IR cut-off for the diagnosis of IDF- and ATPIII-defined MetS in non-diabetic individuals was 1.775 (sensitivity: 57.3%, specificity: 65.3%, with ATPIII; sensitivity: 55.9%, specificity: 64.7%, with IDF). The optimal cut-offs in diabetic individuals were 3.875 (sensitivity: 49.7%, specificity: 69.6%) and 4.325 (sensitivity: 45.4%, specificity: 69.0%) for ATPIII- and IDF-defined MetS, respectively. We determined the optimal HOMA-IR cut-off points for the diagnosis of MetS in the Iranian population with and without diabetes.
Li, Yuping; Xu, Hanyan; Su, Shanshan; Ye, Junru; Chen, Junjie; Jin, Xuru; Lin, Quan; Zhang, Dongqing; Ye, Caier; Chen, Chengshui
2017-01-01
Circulating tumor DNA (ctDNA) is a promising biomarker for noninvasive epidermal growth factor receptor (EGFR) mutations detection in lung cancer patients, but the existing methods have limitations in sensitivity or in availability. In this study, we evaluated the performance of a novel assay called ADx-SuperARMS in detecting EGFR mutations in plasma cell-free DNA from patients with advanced lung adenocarcinoma. A total of 109 patients with metastatic advanced adenocarcinoma were recruited who provided both blood samples and matched tumor tissue samples. EGFR mutation status in plasma samples were tested with ADx-SuperARMS EGFR assay and tumor tissue samples were tested with ADx-ARMS EGFR assay. The clinical sensitivity, specificity, positive prediction value (PPV), and negative prediction value (NPV) of ADx-SuperARMS EGFR assay were calculated by using EGFR mutation status in tumor tissue as standard reference. A receiver operating characteristic (ROC) analysis was implemented and an area under the curve (AUC) was calculated to evaluate sensitivity and specificity of exon 19 deletion (E19Del) and L858R mutation detection. The objective response rate (ORR) were calculated according to the EGFR mutation status determined by ADx-superARMS as well. 0.2% analytical sensitivity and 100% specificity of the ADx-SuperARMS EGFR assays for EGFR E19Del, L858R, and T790M mutants were confirmed by using a series of diluted cell line DNA. In the clinical study, EGFR mutations were detected in 45.9% (50/109) of the plasma samples and in 56.9% (62/109) of the matched tumor tissue samples. The sensitivity, specificity, PPV and NPV of the ADx-SuperARMS EGFR assay for plasma EGFR mutation detection were 82.0% (50/61), 100% (48/48), 100% (50/50), and 81.4% (48/59), respectively. In ROC analysis, ADx-SuperARMS achieved sensitivity and specificity of 88% and 99% in E19Dels as well as sensitivity and specificity of 89% and 100% in L858R, respectively. Among the 35 patients who were plasma EGFR mutation positive and treated with first generation of EGFR-tyrosine kinase inhibitors (TKIs), 23 (65.7%) achieved partial response, 11 (31.4%) sustained disease, and 1 (2.9%) progressive disease. The ORR and disease control rate (DCR) were 65.7% and 97.1%, respectively. ADx-SuperARMS EGFR assay is likely to be a highly sensitive and specific method to noninvasively detect plasma EGFR mutations of patients with advanced lung adenocarcinoma. The EGFR mutations detected by ADx-SuperARMS EGFR assay could predict the efficacy of the treatment with first generation of EGFR-TKIs. Hence, EGFR blood testing with ADx-SuperARMS could address the unmet clinical needs.
Value of circulating cell-free DNA analysis as a diagnostic tool for breast cancer: a meta-analysis
Ma, Xuelei; Zhang, Jing; Hu, Xiuying
2017-01-01
Objectives The aim of this study was to systematically evaluate the diagnostic value of cell free DNA (cfDNA) for breast cancer. Results Among 308 candidate articles, 25 with relevant diagnostic screening qualified for final analysis. The mean sensitivity, specificity and area under the curve (AUC) of SROC plots for 24 studies that distinguished breast cancer patients from healthy controls were 0.70, 0.87, and 0.9314, yielding a DOR of 32.31. When analyzed in subgroups, the 14 quantitative studies produced sensitivity, specificity, AUC, and a DOR of 0.78, 0.83, 0.9116, and 24.40. The 10 qualitative studies produced 0.50, 0.98, 0.9919, and 68.45. For 8 studies that distinguished malignant breast cancer from benign diseases, the specificity, sensitivity, AUC and DOR were 0.75, 0.79, 0.8213, and 9.49. No covariate factors had a significant correlation with relative DOR. Deek's funnel plots indicated an absence of publication bias. Materials and Methods Databases were searched for studies involving the use of cfDNA to diagnose breast cancer. The studies were analyzed to determine sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio (DOR), and the summary receiver operating characteristic (SROC). Covariates were evaluated for effect on relative DOR. Deek's Funnel plots were generated to measure publication bias. Conclusions Our analysis suggests a promising diagnostic potential of using cfDNA for breast cancer screening, but this diagnostic method is not yet independently sufficient. Further work refining qualitative cfDNA assays will improve the correct diagnosis of breast cancers. PMID:28460452
Srihatrai, Parinya; Hlowchitsieng, Thanita
2018-01-01
The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45° and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists' examinations as a gold standard. When fundus photographs of the participants' 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, κ = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%-79.7%) and 99.3% (95% CI; 97.4%-99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%-91.1%) and 98.6% (95% CI; 96.5%-99.6%), respectively. The receiver operating characteristic was 0.85 (0.80-0.90) for single-field photographs and 0.92 (0.88-0.95) for five-field photographs. The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single- and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy.
NASA Astrophysics Data System (ADS)
Chen, Xue; Li, Xiaohui; Yu, Xin; Chen, Deying; Liu, Aichun
2018-01-01
Diagnosis of malignancies is a challenging clinical issue. In this work, we present quick and robust diagnosis and discrimination of lymphoma and multiple myeloma (MM) using laser-induced breakdown spectroscopy (LIBS) conducted on human serum samples, in combination with chemometric methods. The serum samples collected from lymphoma and MM cancer patients and healthy controls were deposited on filter papers and ablated with a pulsed 1064 nm Nd:YAG laser. 24 atomic lines of Ca, Na, K, H, O, and N were selected for malignancy diagnosis. Principal component analysis (PCA), linear discriminant analysis (LDA), quadratic discriminant analysis (QDA), and k nearest neighbors (kNN) classification were applied to build the malignancy diagnosis and discrimination models. The performances of the models were evaluated using 10-fold cross validation. The discrimination accuracy, confusion matrix and receiver operating characteristic (ROC) curves were obtained. The values of area under the ROC curve (AUC), sensitivity and specificity at the cut-points were determined. The kNN model exhibits the best performances with overall discrimination accuracy of 96.0%. Distinct discrimination between malignancies and healthy controls has been achieved with AUC, sensitivity and specificity for healthy controls all approaching 1. For lymphoma, the best discrimination performance values are AUC = 0.990, sensitivity = 0.970 and specificity = 0.956. For MM, the corresponding values are AUC = 0.986, sensitivity = 0.892 and specificity = 0.994. The results show that the serum-LIBS technique can serve as a quick, less invasive and robust method for diagnosis and discrimination of human malignancies.
Assessment of nasalance and nasality in patients with a repaired cleft palate.
Sinko, Klaus; Gruber, Maike; Jagsch, Reinhold; Roesner, Imme; Baumann, Arnulf; Wutzl, Arno; Denk-Linnert, Doris-Maria
2017-07-01
In patients with a repaired cleft palate, nasality is typically diagnosed by speech language pathologists. In addition, there are various instruments to objectively diagnose nasalance. To explore the potential of nasalance measurements after cleft palate repair by NasalView ® , we correlated perceptual nasality and instrumentally measured nasalance of eight speech items and determined the relationship between sensitivity and specificity of the nasalance measures by receiver-operating characteristics (ROC) analyses and AUC (area under the curve) computation for each single test item and specific item groups. We recruited patients with a primarily repaired cleft palate receiving speech therapy during follow-up. During a single day visit, perceptive and instrumental assessments were obtained in 36 patients and analyzed. The individual perceptual nasality was assigned to one of four categories; the corresponding instrumental nasalance measures for the eight specific speech items were expressed on a metric scale (1-100). With reference to the perceptual diagnoses, we observed 3 nasal and one oral test item with high sensitivity. However, the specificity of the nasality indicating measures was rather low. The four best speech items with the highest sensitivity provided scores ranging from 96.43 to 100%, while the averaged sensitivity of all eight items was below 90%. We conclude that perceptive evaluation of nasality remains state of the art. For clinical follow-up, instrumental nasalance assessment can objectively document subtle changes by analysis of four speech items only. Further studies are warranted to determine the applicability of instrumental nasalance measures in the clinical routine, using discriminative items only.
Gui, Xuwei; Xiao, Heping
2014-01-01
This systematic review and meta-analysis was performed to determine accuracy and usefulness of adenosine deaminase (ADA) in diagnosis of tuberculosis pleurisy. Medline, Google scholar and Web of Science databases were searched to identify related studies until 2014. Two reviewers independently assessed quality of studies included according to standard Quality Assessment of Diagnosis Accuracy Studies (QUADAS) criteria. The sensitivity, specificity, diagnostic odds ratio and other parameters of ADA in diagnosis of tuberculosis pleurisy were analyzed with Meta-DiSC1.4 software, and pooled using the random effects model. Twelve studies including 865 tuberculosis pleurisy patients and 1379 non-tuberculosis pleurisy subjects were identified from 110 studies for this meta-analysis. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnosis odds ratio (DOR) of ADA in the diagnosis of tuberculosis pleurisy were 45.25 (95% CI 27.63-74.08), 0.86 (95% CI 0.84-0.88), 0.88 (95% CI 0.86-0.90), 6.32 (95% CI 4.83-8.26) and 0.15 (95% 0.11-0.22), respectively. The area under the summary receiver operating characteristic curve (SROC) was 0.9340. Our results demonstrate that the sensitivity and specificity of ADA are high in the diagnosis of tuberculosis pleurisy especially when ADA≥50 (U/L). Thus, ADA is a relatively sensitive and specific marker for tuberculosis pleurisy diagnosis. However, it is cautious to apply these results due to the heterogeneity in study design of these studies. Further studies are required to confirm the optimal cut-off value of ADA.
Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.
2014-01-01
Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643
Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G
2014-01-01
Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.
Horvat, Joao V; Durando, Manuela; Milans, Soledad; Patil, Sujata; Massler, Jessica; Gibbons, Girard; Giri, Dilip; Pinker, Katja; Morris, Elizabeth A; Thakur, Sunitha B
2018-06-01
To investigate the impact of background parenchymal enhancement (BPE), amount of fibroglandular tissue (FGT) and menopausal status on apparent diffusion coefficient (ADC) values in differentiation between malignant and benign lesions. In this HIPAA-compliant study, mean ADC values of 218 malignant and 130 benign lesions from 288 patients were retrospectively evaluated. The differences in mean ADC values between benign and malignant lesions were calculated within groups stratified by BPE level (high/low), amount of FGT (dense/non-dense) and menopausal status (premenopausal/postmenopausal). Sensitivities and specificities for distinguishing malignant from benign lesions within different groups were compared for statistical significance. The mean ADC value for malignant lesions was significantly lower compared to that for benign lesions (1.07±0.21 x 10 -3 mm 2 /s vs. 1.53±0.26 x 10 -3 mm 2 /s) (p<0.0001). Using the optimal cut-off point of 1.30 x 10 -3 mm 2 /s, an area under the curve of 0.918 was obtained, with sensitivity and specificity both of 87 %. There was no statistically significant difference in sensitivities and specificities of ADC values between different groups stratified by BPE level, amount of FGT or menopausal status. Differentiation between benign and malignant lesions on ADC values is not significantly affected by BPE level, amount of FGT or menopausal status. • ADC allows differentiation between benign and malignant lesions. • ADC is useful for breast cancer diagnosis despite different patient characteristics. • BPE, FGT or menopause do not significantly affect sensitivity and specificity.
Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy
NASA Astrophysics Data System (ADS)
Gueth, P.; Dauvergne, D.; Freud, N.; Létang, J. M.; Ray, C.; Testa, E.; Sarrut, D.
2013-07-01
Online dose monitoring in proton therapy is currently being investigated with prompt-gamma (PG) devices. PG emission was shown to be correlated with dose deposition. This relationship is mostly unknown under real conditions. We propose a machine learning approach based on simulations to create optimized treatment-specific classifiers that detect discrepancies between planned and delivered dose. Simulations were performed with the Monte-Carlo platform Gate/Geant4 for a spot-scanning proton therapy treatment and a PG camera prototype currently under investigation. The method first builds a learning set of perturbed situations corresponding to a range of patient translation. This set is then used to train a combined classifier using distal falloff and registered correlation measures. Classifier performances were evaluated using receiver operating characteristic curves and maximum associated specificity and sensitivity. A leave-one-out study showed that it is possible to detect discrepancies of 5 mm with specificity and sensitivity of 85% whereas using only distal falloff decreases the sensitivity down to 77% on the same data set. The proposed method could help to evaluate performance and to optimize the design of PG monitoring devices. It is generic: other learning sets of deviations, other measures and other types of classifiers could be studied to potentially reach better performance. At the moment, the main limitation lies in the computation time needed to perform the simulations.
Sun, Tao; Wang, Lingxiang; Guo, Changzhi; Zhang, Guochuan; Hu, Wenhai
2017-05-02
Malignant tumors in the proximal fibula are rare but life-threatening; however, biopsy is not routine due to the high risk of peroneal nerve injury. Our aim was to determine preoperative clinical indicators of malignancy. Between 2004 and 2016, 52 consecutive patients with proximal fibular tumors were retrospectively reviewed. Details of the clinicopathological characteristics including age, gender, location of tumors, the presenting symptoms, the duration of symptoms, and pathological diagnosis were collected. Descriptive statistics were calculated, and univariate and multivariate regression were performed. Of these 52 patients, 84.6% had benign tumors and 15.4% malignant tumors. The most common benign tumors were osteochondromas (46.2%), followed by enchondromas (13.5%) and giant cell tumors (13.5%). The most common malignancy was osteosarcomas (11.5%). The most common presenting symptoms were a palpable mass (52.0%) and pain (46.2%). Pain was the most sensitive (100%) and fourth specific (64%); both high skin temperature and peroneal nerve compression had the highest specificity (98%) and third sensitivity (64%); change in symptoms had the second highest specificity (89%) while 50% sensitivity. Using multivariate regression, palpable pain, high skin temperature, and peroneal nerve compression symptoms were predictors of malignancy. Most tumors in the proximal fibula are benign, and the malignancy is rare. Palpable pain, peroneal nerve compression symptoms, and high skin temperature were specific in predicting malignancy.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Braga, G W; Bordin, J O; Moreira Júnior, G; Kuroda, A
1998-01-01
The direct manual Polybrene test (DPT) and the direct antiglobulin tests (DAT) were employed to detect antibody sensitizing red blood cell (RCB) in patients with clinical and laboratorial findings of autoimmune hemolytic anemia (AIHA). To compare the sensitivity and specificity of DPT and DAT in the diagnosis of AIHA. Eighteen consecutive patients with diagnosis of AIHA were evaluated. The control group consisted of 20 normal volunteers blood donors and 20 patients with sickle cell anemia. All patients and controls were submitted to DPT and DAT. All DAT positive samples were further tested using monospecific reagents (anti-IgG heavy chain and anti-C3d). Positive samples for either DPT or DAT were evaluated by eluate technique using. The dichloromethane (DCM). The DAT was positive in 14 patients and negative in 4 subjects, while the DPT was positive in 17 patients and negative in 1 individual who had a positive DAT owing to complement (C3d). All positive eluates performed with DCM showed RBC autoantibodies with presumed "anti-Rh" specificity. The sensitivity rate of the DPT (94%) was significantly (p < 0.05) higher than the sensitivity rate of DAT (78%) to determine whether IgG was bound in vivo, but no difference was found regarding the specificity of the two tests. 1) The DPT is more sensitive than the DAT in detecting IgG autoantibody on the RBCs of patients with AIHA; 2) because of its simplicity and rapidity, the DPT is a useful additional screening test for the investigation of Coombs-negative AIHA.
Mathematical algorithm for the automatic recognition of intestinal parasites.
Alva, Alicia; Cangalaya, Carla; Quiliano, Miguel; Krebs, Casey; Gilman, Robert H; Sheen, Patricia; Zimic, Mirko
2017-01-01
Parasitic infections are generally diagnosed by professionals trained to recognize the morphological characteristics of the eggs in microscopic images of fecal smears. However, this laboratory diagnosis requires medical specialists which are lacking in many of the areas where these infections are most prevalent. In response to this public health issue, we developed a software based on pattern recognition analysis from microscopi digital images of fecal smears, capable of automatically recognizing and diagnosing common human intestinal parasites. To this end, we selected 229, 124, 217, and 229 objects from microscopic images of fecal smears positive for Taenia sp., Trichuris trichiura, Diphyllobothrium latum, and Fasciola hepatica, respectively. Representative photographs were selected by a parasitologist. We then implemented our algorithm in the open source program SCILAB. The algorithm processes the image by first converting to gray-scale, then applies a fourteen step filtering process, and produces a skeletonized and tri-colored image. The features extracted fall into two general categories: geometric characteristics and brightness descriptions. Individual characteristics were quantified and evaluated with a logistic regression to model their ability to correctly identify each parasite separately. Subsequently, all algorithms were evaluated for false positive cross reactivity with the other parasites studied, excepting Taenia sp. which shares very few morphological characteristics with the others. The principal result showed that our algorithm reached sensitivities between 99.10%-100% and specificities between 98.13%- 98.38% to detect each parasite separately. We did not find any cross-positivity in the algorithms for the three parasites evaluated. In conclusion, the results demonstrated the capacity of our computer algorithm to automatically recognize and diagnose Taenia sp., Trichuris trichiura, Diphyllobothrium latum, and Fasciola hepatica with a high sensitivity and specificity.
Zheng, W Y; Wang, Y; Zhang, Z C; Yan, F
2015-10-05
We examined the immunological characteristics of outer membrane protein omp31 of goat Brucella and its monoclonal antibody. Genomic DNA from the M5 strain of goat Brucella was amplified by polymerase chain reaction and cloned into the prokaryotic expression vector pGEX-4T-1. The expression and immunological characteristics of the fusion protein GST-omp31 were subjected to preliminary western blot detection with goat Brucella rabbit immune serum. The Brucella immunized BALB/c mouse serum was detected using purified protein. The high-potency mouse splenocytes and myeloma Sp2/0 cells were fused. Positive clones were screened by enzyme-linked immunosorbent assay to establish a hybridoma cell line. Mice were inoculated intraperitoneally with hybridoma cells to prepare ascites. The mAb was purified using the n-caprylic acid-ammonium sulfate method. The characteristics of mAb were examined using western blotting and enzyme-linked immunosorbent assay. A 680-base pair band was observed after polymerase chain reaction. Enzyme digestion identification and sequencing showed that the pGEX-4T-1-omp31 prokaryotic expression vector was successfully established; a target band of approximately 57 kDa with an apparent molecular weight consistent with the size of the target fusion protein. At 25°C, the expression of soluble expression increased significantly; the fusion protein GST-omp31 was detected by western blotting. Anti-omp31 protein mAb was obtained from 2 strains of Brucella. The antibody showed strong specificity and sensitivity and did not cross-react with Escherichia coli, Staphylococcus aureus, Bacillus subtilis, Mycobacterium tuberculosis, or Bacillus pyocyaneus. The pGEX-4T-1-omp31 prokaryotic expression vector was successfully established and showed good immunogenicity. The antibody also showed strong specificity and good sensitivity.
Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram
2013-11-01
To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments <3 mm, ET was the time in days for the successful clearance of stone fragments. Correlation was performed between the stone characteristics, number of SWs, and ET. Two multiple regression analysis models defined the number of SWs and ET. Two receiver operating characteristic curves plotted the best MSD cutoff value and optimum SSD for a successful ESWL. Three hundred one patients were ESWL successes. A significant positive correlation was elicited between number of SWs and stone diameter, density and SSD; between ET and stone diameter and density. Multiple regressions concluded 2 equations: Number of SWs = 265.108 + 5.103 x1 + 22.39 x2 + 10.931 x3 ET (days) = -10.85 + 0.031 x1 + 2.11 x2 x1 = stone density (Hounsfield unit [HUs]), x2 = stone diameter (mm), and x3 = SSD (mm). Receiver operating characteristic curves demonstrated a cutoff value of ≤ 934 HUs with 94.4% sensitivity and 66.7% specificity and P = .0211. The SSD curve showed that a distance ≤ 99 mm was 85.7% sensitive, 87.5% specific, P <.0001. Stone disintegration is not recommended if MSD is >934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.
Mathematical algorithm for the automatic recognition of intestinal parasites
Alva, Alicia; Cangalaya, Carla; Quiliano, Miguel; Krebs, Casey; Gilman, Robert H.; Sheen, Patricia; Zimic, Mirko
2017-01-01
Parasitic infections are generally diagnosed by professionals trained to recognize the morphological characteristics of the eggs in microscopic images of fecal smears. However, this laboratory diagnosis requires medical specialists which are lacking in many of the areas where these infections are most prevalent. In response to this public health issue, we developed a software based on pattern recognition analysis from microscopi digital images of fecal smears, capable of automatically recognizing and diagnosing common human intestinal parasites. To this end, we selected 229, 124, 217, and 229 objects from microscopic images of fecal smears positive for Taenia sp., Trichuris trichiura, Diphyllobothrium latum, and Fasciola hepatica, respectively. Representative photographs were selected by a parasitologist. We then implemented our algorithm in the open source program SCILAB. The algorithm processes the image by first converting to gray-scale, then applies a fourteen step filtering process, and produces a skeletonized and tri-colored image. The features extracted fall into two general categories: geometric characteristics and brightness descriptions. Individual characteristics were quantified and evaluated with a logistic regression to model their ability to correctly identify each parasite separately. Subsequently, all algorithms were evaluated for false positive cross reactivity with the other parasites studied, excepting Taenia sp. which shares very few morphological characteristics with the others. The principal result showed that our algorithm reached sensitivities between 99.10%-100% and specificities between 98.13%- 98.38% to detect each parasite separately. We did not find any cross-positivity in the algorithms for the three parasites evaluated. In conclusion, the results demonstrated the capacity of our computer algorithm to automatically recognize and diagnose Taenia sp., Trichuris trichiura, Diphyllobothrium latum, and Fasciola hepatica with a high sensitivity and specificity. PMID:28410387
What constitutes food variety? Stimulus specificity of food.
Epstein, Leonard H; Robinson, Jodie L; Roemmich, James N; Marusewski, Angela L; Roba, Lora G
2010-02-01
Variety is a major influence of energy intake, but it is not known how much foods have to vary to influence eating. Using a stimulus specificity habituation paradigm we assessed the influence of varying the texture and appearance of nutritionally identical foods on responding for food and energy intake, and whether sensitization, or an increase in responding prior to habituation, was related to the rate of habituation or recovery of responding. Children responded for elbow macaroni and cheese until they habituated, then were provided either more elbow macaroni and cheese, spiral macaroni and cheese, or chicken nuggets. Children provided chicken nuggets or spiral macaroni and cheese recovered responding in comparison to more elbow macaroni and cheese. Children who sensitized showed slower habituation and consumed more food and more energy than those who did not sensitize, but did not differ in recovery of responding to the chicken nuggets or spiral macaroni and cheese. Results show small variations in food characteristics lead to recovery of responding and increased intake after children have habituated. 2009 Elsevier Ltd. All rights reserved.
Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne
2017-12-15
Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Predicting drug-induced liver injury using ensemble learning methods and molecular fingerprints.
Ai, Haixin; Chen, Wen; Zhang, Li; Huang, Liangchao; Yin, Zimo; Hu, Huan; Zhao, Qi; Zhao, Jian; Liu, Hongsheng
2018-05-21
Drug-induced liver injury (DILI) is a major safety concern in the drug-development process, and various methods have been proposed to predict the hepatotoxicity of compounds during the early stages of drug trials. In this study, we developed an ensemble model using three machine learning algorithms and 12 molecular fingerprints from a dataset containing 1,241 diverse compounds. The ensemble model achieved an average accuracy of 71.1±2.6%, sensitivity of 79.9±3.6%, specificity of 60.3±4.8%, and area under the receiver operating characteristic curve (AUC) of 0.764±0.026 in five-fold cross-validation and an accuracy of 84.3%, sensitivity of 86.9%, specificity of 75.4%, and AUC of 0.904 in an external validation dataset of 286 compounds collected from the Liver Toxicity Knowledge Base (LTKB). Compared with previous methods, the ensemble model achieved relatively high accuracy and sensitivity. We also identified several substructures related to DILI. In addition, we provide a web server offering access to our models (http://ccsipb.lnu.edu.cn/toxicity/HepatoPred-EL/).
Siemens Immulite Aspergillus-specific IgG assay for chronic pulmonary aspergillosis diagnosis.
Page, Iain D; Richardson, Malcolm D; Denning, David W
2018-05-14
Chronic pulmonary aspergillosis (CPA) complicates underlying lung disease, including treated tuberculosis. Measurement of Aspergillus-specific immunoglobulin G (IgG) is a key diagnostic step. Cutoffs have been proposed based on receiver operating characteristic (ROC) curve analyses comparing CPA cases to healthy controls, but performance in at-risk populations with underlying lung disease is unclear. We evaluated optimal cutoffs for the Siemens Immulite Aspergillus-specific IgG assay for CPA diagnosis in relation to large groups of healthy and diseased controls with treated pulmonary tuberculosis. Sera from 241 patients with CPA attending the UK National Aspergillosis Centre, 299 Ugandan blood donors (healthy controls), and 398 Ugandans with treated pulmonary tuberculosis (diseased controls) were tested. Radiological screening removed potential CPA cases from diseased controls (234 screened diseased controls). ROC curve analyses were performed and optimal cutoffs identified by Youden J statistic. CPA versus control ROC area under curve (AUC) results were: healthy controls 0.984 (95% confidence interval 0.972-0.997), diseased controls 0.972 (0.959-0.985), screened diseased controls 0.979 (0.967-0.992). Optimal cutoffs were: healthy controls 15 mg/l (94.6% sensitivity, 98% specificity), unscreened diseased controls 15 mg/l (94.6% sensitivity, 94.5% specificity), screened diseased controls 25 mg/l (92.9% sensitivity, 98.7% specificity). Results were similar in healthy and diseased controls. We advocate a cutoff of 20 mg/l as this is the midpoint of the range of optimal cutoffs. Cutoffs calculated in relation to healthy controls for other assays are likely to remain valid for use in a treated tuberculosis population.
Afanas'ev, M V; Chipanin, E V; Shestakov, V E; Denisov, A V; Fomina, L A; Ostiak, A S; Balakhonov, S V
2013-03-01
The article presents the results of development and practical implementation of system of polymerase chain reaction testing in real-time operation mode to detect agent of plague infield material. In laboratory conditions the system demonstrated good results and hence it was applied in conditions of field laboratory of epidemiologic team during planned epizootologic examination of Gorno-Altaisk hot spot of plague. The sampling consisted of more than 1400 objects. It was demonstrated that high sensitivity and specificity is immanent to proposed system. The adaptation of the system to the real time amplifier "Smart Cycler" (Cephid, USA) having some specific technical characteristics makes it possible to consider the proposed test-system as an effective sensitive and precise instrument for screening studies in the process of regular epizootologic examinations of hot spots of plague.
Using the ADAP Learning Algorithm to Forecast the Onset of Diabetes Mellitus
Smith, Jack W.; Everhart, J.E.; Dickson, W.C.; Knowler, W.C.; Johannes, R.S.
1988-01-01
Neural networks or connectionist models for parallel processing are not new. However, a resurgence of interest in the past half decade has occurred. In part, this is related to a better understanding of what are now referred to as hidden nodes. These algorithms are considered to be of marked value in pattern recognition problems. Because of that, we tested the ability of an early neural network model, ADAP, to forecast the onset of diabetes mellitus in a high risk population of Pima Indians. The algorithm's performance was analyzed using standard measures for clinical tests: sensitivity, specificity, and a receiver operating characteristic curve. The crossover point for sensitivity and specificity is 0.76. We are currently further examining these methods by comparing the ADAP results with those obtained from logistic regression and linear perceptron models using precisely the same training and forecasting sets. A description of the algorithm is included.
Evaluation of YB-1 levels in patients with endometriosis.
Ahrens, Thorben; Silveira, Cassia G T; Banz-Jansen, Constanze; Rody, Achim; Hornung, Daniela
2015-08-01
The objective of this study is the evaluation of serum YB-1 levels in the diagnosis of endometriosis. Serum samples of 12 patients with histologically confirmed endometriosis and of 10 control patients were collected. Western blot analysis was used to assess serum YB-1 levels. Groups were compared with Student's t-test or, if not normally distributed, with the Mann-Whitney test. Sensitivity and specificity for the potential diagnostic performance of serum YB-1 were assessed by receiver operating characteristic (ROC) curves. Serum YB-1 levels were significantly higher in patients with endometriosis (=0.004). The area under the curve was 0.867 (95% confidence interval 0.714-1.019) with sensitivity and specificity of 83.3% and 70% respectively. Serum YB-1 levels in patients with endometriosis are significantly higher compared to control patients and may be used as a potential diagnostic biomarker for endometriosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Photoacoustic Spectroscopy Analysis of Traditional Chinese Medicine
NASA Astrophysics Data System (ADS)
Chen, Lu; Zhao, Bin-xing; Xiao, Hong-tao; Tong, Rong-sheng; Gao, Chun-ming
2013-09-01
Chinese medicine is a historic cultural legacy of China. It has made a significant contribution to medicine and healthcare for generations. The development of Chinese herbal medicine analysis is emphasized by the Chinese pharmaceutical industry. This study has carried out the experimental analysis of ten kinds of Chinese herbal powder including Fritillaria powder, etc., based on the photoacoustic spectroscopy (PAS) method. First, a photoacoustic spectroscopy system was designed and constructed, especially a highly sensitive solid photoacoustic cell was established. Second, the experimental setup was verified through the characteristic emission spectrum of the light source, obtained by using carbon as a sample in the photoacoustic cell. Finally, as the photoacoustic spectroscopy analysis of Fritillaria, etc., was completed, the specificity of the Chinese herb medicine analysis was verified. This study shows that the PAS can provide a valid, highly sensitive analytical method for the specificity of Chinese herb medicine without preparing and damaging samples.
CSF ADA Determination in Early Diagnosis of Tuberculous Meningitis in HIV-Infected Patients.
Ghosh, Gopal Chandra; Sharma, Brijesh; Gupta, B B
2016-01-01
Tuberculous and Cryptococcal meningitis are common in HIV patients. A highly specific and sensitive rapid test for diagnosis of Tuberculous meningitis especially in setting of HIV is not available in developing countries where the burden of disease is high. We measured ADA (adenosine deaminase) levels using spectrophotometric method in the CSF of HIV patients with meningitis to differentiate Tuberculous meningitis from meningitis due to other causes. Kruskal-Wallis test was used to compare ADA values between tuberculous meningitis (TBM) and nontuberculous (non-TB) meningitis patients and a receiver-operating characteristic (ROC) analysis curve was drawn from these values. Levels of ADA in the CSF of patients with TBM were significantly higher than those in patients with meningitis due to other causes. CSF ADA level determination with a cut-off value of 6 IU/L was found to be highly specific and fairly sensitive test for the diagnosis of TBM in HIV positive patients.
Metternich, Birgitta; Wagner, Kathrin; Buschmann, Franziska; Anger, Robin; Schulze-Bonhage, Andreas
2012-12-01
Goal of the present study was the validation of a German version of the Neurological Disorders Depression Inventory for Epilepsy (NDDI-E). 197 adult epilepsy patients completed the NDDI-E (185 completed both the NDDI-E and BDI). 95 patients received psychiatric consults. 33 patients received a diagnosis of major depression according to ICD-10 criteria. Internal consistency of the NDDI-E was .83. Receiver operating characteristics (ROC) showed an area under the curve of 0.92. Applying a cutoff score of ≥14 resulted in both sensitivity and specificity of 0.85. In the subsample with psychiatric consult, at the same optimal cutoff, sensitivity was 0.92, and specificity was 0.86. Further analyses showed a high concurrent validity with the BDI. The German version of the NDDI-E constitutes a brief and reliable depression screening instrument for epilepsy patients. Copyright © 2012 Elsevier Inc. All rights reserved.
[Possibilities of the TruScreen for screening of precancer and cancer of the uterine cervix].
Zlatkov, V
2009-01-01
The classic approach of detection of pre-cancer and cancer of uterine cervix includes cytological examination, followed by colposcopy assessment of the detected cytological abnormalities. Real-time devices use in-vivo techniques for the measurement, computerized analysis and classifying of different types of cervical tissues. The aim of the present review is to present the technical characteristics and to discus the diagnostic possibilities of TruScreen-automated optical-electron system for cervical screening. The analysis of the presented in the literature diagnostic value of the method at different grades intraepithelial lesions shows that it has higher sensitivity (67-70%) and lower specificity (81%) in comparison to the Pap test with the following results (45-69% sensitivity and 95% specificity). This makes the method suitable for independent primary screening, as well as for adding the diagnostic assurance of the cytological method.
Mandalà, Marco; Giannuzzi, Annalisa; Astore, Serena; Trabalzini, Franco; Nuti, Daniele
2013-07-01
We evaluated the incidence and characteristics of hyperventilation-induced nystagmus (HVN) in 49 patients with gadolinium-enhanced magnetic resonance imaging evidence of vestibular schwannoma and 53 patients with idiopathic unilateral sensorineural hearing loss and normal radiological findings. The sensitivity and specificity of the hyperventilation test were compared with other audio-vestibular diagnostic tests (bedside examination of eye movements, caloric test, auditory brainstem responses) in the two groups of patients. The hyperventilation test scored the highest diagnostic efficiency (sensitivity 65.3 %; specificity 98.1 %) of the four tests in the differential diagnosis of vestibular schwannoma and idiopathic unilateral sensorineural hearing loss. Small tumors with a normal caloric response or caloric paresis were associated with ipsilateral HVN and larger tumors and severe caloric deficits with contralateral HVN. These results confirm that the hyperventilation test is a useful diagnostic test for predicting vestibular schwannoma in patients with unilateral sensorineural hearing loss.
"Hook"-calibration of GeneChip-microarrays: theory and algorithm.
Binder, Hans; Preibisch, Stephan
2008-08-29
: The improvement of microarray calibration methods is an essential prerequisite for quantitative expression analysis. This issue requires the formulation of an appropriate model describing the basic relationship between the probe intensity and the specific transcript concentration in a complex environment of competing interactions, the estimation of the magnitude these effects and their correction using the intensity information of a given chip and, finally the development of practicable algorithms which judge the quality of a particular hybridization and estimate the expression degree from the intensity values. : We present the so-called hook-calibration method which co-processes the log-difference (delta) and -sum (sigma) of the perfect match (PM) and mismatch (MM) probe-intensities. The MM probes are utilized as an internal reference which is subjected to the same hybridization law as the PM, however with modified characteristics. After sequence-specific affinity correction the method fits the Langmuir-adsorption model to the smoothed delta-versus-sigma plot. The geometrical dimensions of this so-called hook-curve characterize the particular hybridization in terms of simple geometric parameters which provide information about the mean non-specific background intensity, the saturation value, the mean PM/MM-sensitivity gain and the fraction of absent probes. This graphical summary spans a metrics system for expression estimates in natural units such as the mean binding constants and the occupancy of the probe spots. The method is single-chip based, i.e. it separately uses the intensities for each selected chip. : The hook-method corrects the raw intensities for the non-specific background hybridization in a sequence-specific manner, for the potential saturation of the probe-spots with bound transcripts and for the sequence-specific binding of specific transcripts. The obtained chip characteristics in combination with the sensitivity corrected probe-intensity values provide expression estimates scaled in natural units which are given by the binding constants of the particular hybridization.
Identification of the need for home visiting nurse: development of a new assessment tool
Taguchi, Atsuko; Nagata, Satoko; Naruse, Takashi; Kuwahara, Yuki; Yamaguchi, Takuhiro; Murashima, Sachiyo
2014-01-01
Objective To develop a Home Visiting Nursing Service Need Assessment Form (HVNS-NAF) to standardize the decision about the need for home visiting nursing service. Methods The sample consisted of older adults who had received coordinated services by care managers. We defined the need for home visiting nursing service by elderly individuals as the decision of the need by a care manager so that the elderly can continue to live independently. Explanatory variables included demographic factors, medical procedure, severity of illness, and caregiver variables. Multiple logistic regression was carried out after univariate analyses to decide the variables to include and the weight of each variable in the HVNS-NAF. We then calculated the sensitivity and specificity of each cutoff value, and defined the score with the highest sensitivity and specificity as the cutoff value. Results Nineteen items were included in the final HVNS-NAF. When the cutoff value was 2 points, the sensitivity was 77.0%, specificity 68.5%, and positive predictive value 56.8%. Conclusions HVNS-NAF is the first validated standard based on characteristics of elderly clients who required home visiting nursing service. Using the HVNS-NAF may result in reducing the unmet need for home visiting nursing service and preventing hospitalization. PMID:24665229
Accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue.
Zhang, Jing; Fan, Yimeng; He, Min; Ma, Xuelei; Song, Yanlin; Liu, Ming; Xu, Jianguo
2017-05-30
Raman spectroscopy could be applied to distinguish tumor from normal tissues. This meta-analysis was conducted to assess the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. PubMed and Embase were searched to identify suitable studies prior to Jan 1st, 2016. We estimated the pooled sensitivity, specificity, positive and negative likelihood ratios (LR), diagnostic odds ratio (DOR), and constructed summary receiver operating characteristics (SROC) curves to identity the accuracy of Raman spectroscopy in differentiating brain tumor from normal brain tissue. A total of six studies with 1951 spectra were included. For glioma, the pooled sensitivity and specificity of Raman spectroscopy were 0.96 (95% CI 0.94-0.97) and 0.99 (95% CI 0.98-0.99), respectively. The area under the curve (AUC) was 0.9831. For meningioma, the pooled sensitivity and specificity were 0.98 (95% CI 0.94-1.00) and 1.00 (95% CI 0.98-1.00), respectively. The AUC was 0.9955. This meta-analysis suggested that Raman spectroscopy could be an effective and accurate tool for differentiating glioma and meningioma from normal brain tissue, which would help us both avoid removal of normal tissue and minimize the volume of residual tumor.
te Beest, Dennis; de Bruin, Erwin; Imholz, Sandra; Wallinga, Jacco; Teunis, Peter; Koopmans, Marion; van Boven, Michiel
2014-01-01
Reliable discrimination of recent influenza A infection from previous exposure using hemagglutination inhibition (HI) or virus neutralization tests is currently not feasible. This is due to low sensitivity of the tests and the interference of antibody responses generated by previous infections. Here we investigate the diagnostic characteristics of a newly developed antibody (HA1) protein microarray using data from cross-sectional serological studies carried out before and after the pandemic of 2009. The data are analysed by mixture models, providing a probabilistic classification of sera (susceptible, prior-exposed, recently infected). Estimated sensitivity and specificity for identifying A/2009 infections are low using HI (66% and 51%), and high when using A/2009 microarray data alone or together with A/1918 microarray data (96% and 95%). As a heuristic, a high A/2009 to A/1918 antibody ratio (>1.05) is indicative of recent infection, while a low ratio is indicative of a pre-existing response, even if the A/2009 titer is high. We conclude that highly sensitive and specific classification of individual sera is possible using the protein microarray, thereby enabling precise estimation of age-specific infection attack rates in the population even if sample sizes are small. PMID:25405997
The Diagnostic Value of Gastrin-17 Detection in Atrophic Gastritis
Wang, Xu; Ling, Li; Li, Shanshan; Qin, Guiping; Cui, Wei; Li, Xiang; Ni, Hong
2016-01-01
Abstract A meta-analysis was performed to assess the diagnostic value of gastrin-17 (G-17) for the early detection of chronic atrophic gastritis (CAG). An extensive literature search was performed, with the aim of selecting publications that reported the accuracy of G-17 in predicting CAG, in the following databases: PubMed, Science Direct, Web of Science, Chinese Biological Medicine, Chinese National Knowledge Infrastructure, Wanfang, and VIP. To assess the diagnostic value of G-17, the following statistics were estimated and described: sensitivity, specificity, diagnostic odds ratios (DOR), summary receiver operating characteristic curves, area under the curve (AUC), and 95% confidence intervals (CIs). Thirteen studies that met the inclusion criteria were included in this meta-analysis, comprising 894 patients and 1950 controls. The pooled sensitivity and specificity of these studies were 0.48 (95% CI: 0.45–0.51) and 0.79 (95% CI: 0.77–0.81), respectively. The DOR was 5.93 (95% CI: 2.93–11.99), and the AUC was 0.82. G-17 may have potential diagnostic value because it has good specificity and a moderate DOR and AUC for CAG. However, more studies are needed to improve the sensitivity of this diagnostic tool in the future. PMID:27149493
Lord, Emily; Newnham, Tana; Dorrell, Lucy; Jesuthasan, Gerald; Clarke, Lorraine; Jeffery, Katie; Sherrard, Jackie
2017-03-01
Trichomonas vaginalis (TV) rates in women are increasing and many are asymptomatic. Nucleic acid amplification tests (NAATs) are becoming the 'gold standard' for diagnosis. We aimed to establish our asymptomatic TV rates by testing all women attending Oxfordshire's Sexual Health service, regardless of symptoms, using the BD ProbeTec™ TV Q x NAATs (BDQ x ). During BDQ x 's verification process, the sensitivity and specificity were calculated using results of 220 endocervical samples from symptomatic women, compared with culture. BDQ x was subsequently implemented and prospectively evaluated over 6 months in female attendees. Wet mount microscopy was also performed in symptomatics. Demographic and clinical characteristics of those diagnosed were analysed. From 220 samples tested by BDQ x and culture: 5 were positive on both and one solely using BDQ x , giving a sensitivity and specificity of 100% and 99.53%, respectively. In the prospective cohort, of 5775 BDQ x tests, 33 (0.57%) were positive. 11/33 (33%) patients were asymptomatic. All patients diagnosed had risk factors: age >25 years (85%), residence in a deprived area (79%) and black ethnicity (21%). Despite BDQ x being highly sensitive and specific, with our low TV prevalence universal screening may not be justified. Targeted screening using local demographic data merits further investigation.
Esmaily, Habibollah; Tayefi, Maryam; Doosti, Hassan; Ghayour-Mobarhan, Majid; Nezami, Hossein; Amirabadizadeh, Alireza
2018-04-24
We aimed to identify the associated risk factors of type 2 diabetes mellitus (T2DM) using data mining approach, decision tree and random forest techniques using the Mashhad Stroke and Heart Atherosclerotic Disorders (MASHAD) Study program. A cross-sectional study. The MASHAD study started in 2010 and will continue until 2020. Two data mining tools, namely decision trees, and random forests, are used for predicting T2DM when some other characteristics are observed on 9528 subjects recruited from MASHAD database. This paper makes a comparison between these two models in terms of accuracy, sensitivity, specificity and the area under ROC curve. The prevalence rate of T2DM was 14% among these subjects. The decision tree model has 64.9% accuracy, 64.5% sensitivity, 66.8% specificity, and area under the ROC curve measuring 68.6%, while the random forest model has 71.1% accuracy, 71.3% sensitivity, 69.9% specificity, and area under the ROC curve measuring 77.3% respectively. The random forest model, when used with demographic, clinical, and anthropometric and biochemical measurements, can provide a simple tool to identify associated risk factors for type 2 diabetes. Such identification can substantially use for managing the health policy to reduce the number of subjects with T2DM .
Goudemand, J; Caron, C; De Prost, D; Derlon, A; Borg, J Y; Sampol, J; Sié, P
1997-02-01
This study was designed to test the sensitivity and specificity of a combination of 3 phospholipid-dependent assays performed with various reagents, for the detection of lupus anticoagulant (LA). Plasmas containing an LA (n = 56) or displaying various confounding pathologies [58 intrinsic pathway factor deficiencies, 9 factor VIII inhibitors, 28 plasmas from patients treated with an oral anticoagulant (OAC)] were selected. In a first step, the efficiency of each assay and reagent was assessed using the Receiving Operating Characteristic (ROC) method. Optimal cut-offs providing both sensitivity and specificity > or = 80% were determined. The APTT assay and most of the phospholipid neutralization assays failed to discriminate factor VIII inhibitors from LA. In a second step, using the optimal cut-offs determined above, the results of all the possible combinations of the 3 assays performed with 4 different reagents were analyzed. Thirteen combinations of reagents allowed > or = 80% of plasmas of each category (LA, factor deficiency or OAC) to be correctly classified (3/3 positive test results in LA-containing plasmas and 0/3 positive results in LA-negative samples).
Higashi, Akifumi; Dohi, Yoshihiro; Yamabe, Sayuri; Kinoshita, Hiroki; Sada, Yoshiharu; Kitagawa, Toshiro; Hidaka, Takayuki; Kurisu, Satoshi; Yamamoto, Hideya; Yasunobu, Yuji; Kihara, Yasuki
2017-11-01
Cardiopulmonary exercise testing (CPET) is useful for the evaluation of patients with suspected or confirmed pulmonary hypertension (PH). End-tidal carbon dioxide pressure (PETCO 2 ) during exercise is reduced with elevated pulmonary artery pressure. However, the utility of ventilatory parameters such as CPET for detecting PH remains unclear. We conducted a review in 155 patients who underwent right heart catheterization and CPET. Fifty-nine patients had PH [mean pulmonary arterial pressure (mPAP) ≥25 mmHg]. There was an inverse correlation between PETCO 2 at the anaerobic threshold (AT) and mPAP (r = -0.66; P < 0.01). Multiple regression analysis showed that PETCO 2 at the AT was independently associated with an elevated mPAP (P = 0.04). The sensitivity and specificity of CPET for PH were 80 and 86%, respectively, when the cut-off value identified by receiver operating characteristic curve analysis for PETCO 2 at the AT was ≤34.7 mmHg. A combination of echocardiography and CPET improved the sensitivity in detecting PH without markedly reducing specificity (sensitivity 87%, specificity 85%). Evaluation of PETCO 2 at the AT is useful for estimating pulmonary pressure. A combination of CPET and previous screening algorithms for PH may enhance the diagnostic ability of PH.
Validity of the Hum Test, a Simple and Reliable Alternative to the Weber Test.
Ahmed, Omar H; Gallant, Sara C; Ruiz, Ryan; Wang, Binhuan; Shapiro, William H; Voigt, Erich P
2018-06-01
To compare the diagnostic performance of the Hum Test against the Weber Test using pure tone audiometry (PTA) as the "gold standard" comparator. 29 participants with normal hearing of ages 18 to 35 without any history of hearing abnormalities or otologic conditions were enrolled. Subjects underwent three tests (Hum Test, Weber Test, and PTA) across two conditions: with an ear plug in one ear (side randomized) and without ear plugs. When examining the ability of the Hum Test to detect simulated conductive hearing loss (CHL), the test had a sensitivity of 89.7% and specificity of 100% with high pitched humming and 93.1% and 100%, respectively, with low pitched humming. The Weber Test had a sensitivity and specificity of 96.6% and 100%, respectively. McNemar's test demonstrated agreement between the Hum Test, performed with either high pitched ( P = .32) or low pitched ( P = .56) humming, and the Weber Test. Receiver operating characteristic (ROC) curves for the Hum Test (both high and low pitched) and Weber test were compared and demonstrated no statistically significant difference. The Hum Test is comparable to the Weber Test with regards to its sensitivity, specificity, and diagnostic accuracy in assessing new onset unilateral CHL in previously normal hearing subjects.
Zheng, Jun; Yu, Zhiyuan; Guo, Rui; Li, Hao; You, Chao; Ma, Lu
2018-04-27
Hematoma expansion is related to unfavorable prognosis in intracerebral hemorrhage (ICH). The black hole sign is a novel marker on non-contrast computed tomography for predicting hematoma expansion. However, its predictive values are different in previous studies. Thus, this meta-analysis was conducted to evaluate the predictive significance of the black hole sign for hematoma expansion in ICH. A systematic literature search was performed. Original researches on the association between the black hole sign and hematoma expansion in ICH were included. Sensitivity and specificity were pooled to assess the predictive accuracy. Summary receiver operating characteristics curve (SROC) was developed. Deeks' funnel plot asymmetry test was used to assess the publication bias. Five studies with a total of 1495 patients were included in this study. The pooled sensitivity and specificity of the black hole sign for predicting hematoma expansion were 0.30 and 0.91, respectively. The area under the curve was 0.78 in SROC curve. There was no significant publication bias. This meta-analysis shows that the black hole sign is a helpful imaging marker for predicting hematoma expansion in ICH. Although the black hole sign has a relatively low sensitivity, its specificity is relatively high. Copyright © 2018 Elsevier Inc. All rights reserved.
Ha, Hong Ku; Koo, Phillip J; Kim, Seong-Jang
2018-05-30
We aimed to assess the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for preoperative lymph node (LN) staging in newly diagnosed bladder cancer (BC) patients through a systematic review and meta-analysis. MEDLINE, Embase, and the Cochrane Library database, from the earliest available date of indexing through June 30, 2017, were searched for studies evaluating the diagnostic performance of F-18 FDG PET/CT for preoperative LN staging in newly diagnosed BC. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves. Across 14 studies (785 patients), the pooled sensitivity was 0.57 (95% CI: 0.49-0.64) and the pooled specificity was 0.92 (95% CI: 0.87-0.95). The LR syntheses gave an overall LR+ of 7.4 (95% CI: 4.4-12.3) and an LR- of 0.47 (95% CI: 0.39-0.56). The pooled diagnostic odds ratio was 16 (95% CI: 9-28). F-18 FDG PET/CT shows a low sensitivity and high specificity for the detection of metastatic LNs in patients with newly diagnosed BC. © 2018 S. Karger AG, Basel.
El-Sayed, Abdulrahman M; Lauderdale, Diane S; Galea, Sandro
2010-12-01
Data about Arab-Americans, a growing ethnic minority, are not routinely collected in vital statistics, registry, or administrative data in the USA. The difficulty in identifying Arab-Americans using publicly available data sources is a barrier to health research about this group. Here, we validate an empirically based probabilistic Arab name algorithm (ANA) for identifying Arab-Americans in health research. We used data from all Michigan birth certificates between 2000 and 2005. Fathers' surnames and mothers' maiden names were coded as Arab or non-Arab according to the ANA. We calculated sensitivity, specificity, and positive (PPV) and negative predictive values (NPV) of Arab ethnicity inferred using the ANA as compared to self-reported Arab ancestry. Statewide, the ANA had a specificity of 98.9%, a sensitivity of 50.3%, a PPV of 57.0%, and an NPV of 98.6%. Both the false-positive and false-negative rates were higher among men than among women. As the concentration of Arab-Americans in a study locality increased, the ANA false-positive rate increased and false-negative rate decreased. The ANA is highly specific but only moderately sensitive as a means of detecting Arab ancestry. Future research should compare health characteristics among Arab-American populations defined by Arab ancestry and those defined by the ANA.
Li, Zhanzhan; Zhou, Qin; Li, Yanyan; Yan, Shipeng; Fu, Jun; Huang, Xinqiong; Shen, Liangfang
2017-02-28
We conducted a meta-analysis to evaluate the diagnostic values of mean cerebral blood volume for recurrent and radiation injury in glioma patients. We performed systematic electronic searches for eligible study up to August 8, 2016. Bivariate mixed effects models were used to estimate the combined sensitivity, specificity, positive likelihood ratios, negative likelihood ratios, diagnostic odds ratios and their 95% confidence intervals (CIs). Fifteen studies with a total number of 576 participants were enrolled. The pooled sensitivity and specificity of diagnostic were 0.88 (95%CI: 0.82-0.92) and 0.85 (95%CI: 0.68-0.93). The pooled positive likelihood ratio is 5.73 (95%CI: 2.56-12.81), negative likelihood ratio is 0.15 (95%CI: 0.10-0.22), and the diagnostic odds ratio is 39.34 (95%CI:13.96-110.84). The summary receiver operator characteristic is 0.91 (95%CI: 0.88-0.93). However, the Deek's plot suggested publication bias may exist (t=2.30, P=0.039). Mean cerebral blood volume measurement methods seems to be very sensitive and highly specific to differentiate recurrent and radiation injury in glioma patients. The results should be interpreted with caution because of the potential bias.
Detection of Fusarium verticillioides by PCR-ELISA based on FUM21 gene.
Omori, Aline Myuki; Ono, Elisabete Yurie Sataque; Bordini, Jaqueline Gozzi; Hirozawa, Melissa Tiemi; Fungaro, Maria Helena Pelegrinelli; Ono, Mario Augusto
2018-08-01
Fusarium verticillioides is a primary corn pathogen and fumonisin producer which is associated with toxic effects in humans and animals. The traditional methods for detection of fungal contamination based on morphological characteristics are time-consuming and show low sensitivity and specificity. Therefore, the objective of this study was to develop a PCR-ELISA based on the FUM21 gene for F. verticillioides detection. The DNA of the F. verticillioides, Fusarium sp., Aspergillus sp. and Penicillium sp. isolates was analyzed by conventional PCR and PCR-ELISA to determine the specificity. The PCR-ELISA was specific to F. verticillioides isolates, showed a 2.5 pg detection limit and was 100-fold more sensitive than conventional PCR. In corn samples inoculated with F. verticillioides conidia, the detection limit of the PCR-ELISA was 1 × 10 4 conidia/g and was also 100-fold more sensitive than conventional PCR. Naturally contaminated corn samples were analyzed by PCR-ELISA based on the FUM21 gene and PCR-ELISA absorbance values correlated positively (p < 0.05) with Fusarium sp. counts (CFU/g). These results suggest that the PCR-ELISA developed in this study can be useful for F. verticillioides detection in corn samples. Copyright © 2018 Elsevier Ltd. All rights reserved.
Eberhardt, Melanie; Nadig, Aparna
2018-01-01
We present two experiments examining the universality and uniqueness of reduced context sensitivity in language processing in Autism Spectrum Disorders (ASD), as proposed by the Weak Central Coherence account (Happé & Frith, 2006, Journal of Autism and Developmental Disorders, 36(1), 25). That is, do all children with ASD exhibit decreased context sensitivity, and is this characteristic specific to ASD versus other neurodevelopmental conditions? Experiment 1, conducted in English, was a comparison of children with ASD with normal language and their typically-developing peers on a picture selection task where interpretation of sentential context was required to identify homonyms. Contrary to the predictions of Weak Central Coherence, the ASD-normal language group exhibited no difficulty on this task. Experiment 2, conducted in German, compared children with ASD with variable language abilities, typically-developing children, and a second control group of children with Language Impairment (LI) on a sentence completion task where a context sentence had to be considered to produce the continuation of an ambiguous sentence fragment. Both ASD-variable language and LI groups exhibited reduced context sensitivity and did not differ from each other. Finally, to directly test which factors contribute to reduced context sensitivity, we conducted a regression analysis for each experiment, entering nonverbal IQ, structural language ability, and autism diagnosis as predictors. For both experiments structural language ability emerged as the only significant predictor. These convergent findings demonstrate that reduced sensitivity to context in language processing is linked to low structural language rather than ASD diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Joint effects of child temperament and maternal sensitivity on the development of childhood obesity.
Wu, Tiejian; Dixon, Wallace E; Dalton, William T; Tudiver, Fred; Liu, Xuefeng
2011-05-01
The interplay between child characteristics and parenting is increasingly implicated as crucial to child health outcomes. This study assessed the joint effects of children's temperamental characteristics and maternal sensitivity on children's weight status. Data from the National Institute of Child Health and Human Development's Study of Early Child Care and Youth Development were utilized. Infant temperament, assessed at child's age of 6 months by maternal report, was categorized into three types: easy, average, and difficult. Maternal sensitivity, assessed at child's age of 6 months by observing maternal behaviors during mother-child semi-structured interaction, was categorized into two groups: sensitive and insensitive. Children's height and weight were measured longitudinally from age 2 years to Grade 6, and body mass index (BMI) was calculated. BMI percentile was obtained based on the Centers for Disease Control and Prevention's BMI charts. Children, who had a BMI ≥ the 85th percentile, were defined as overweight-or-obese. Generalized estimating equations were used to analyze the data. The proportions of children overweight-or-obese increased with age, 15.58% at 2 years old to 34.34% by Grade 6. The joint effects of children's temperament and maternal sensitivity on a child's body mass status depended on the child's age. For instance, children with difficult temperament and insensitive mothers had significantly higher risks for being overweight-or-obese during the school age phase but not during early childhood. Specific combinations of child temperament and maternal sensitivity were associated with the development of obesity during childhood. Findings may hold implications for childhood obesity prevention/intervention programs targeting parents.
NASA Astrophysics Data System (ADS)
Audet, P.; Arnold, S.; Lechner, A. M.; Baumgartl, T.
2013-10-01
In eastern Australia, the availability of water is critical for the successful rehabilitation of post-mining landscapes and climatic characteristics of this diverse geographical region are closely defined by factors such as erratic rainfall and periods of drought and flooding. Despite this, specific metrics of climate patterning are seldom incorporated into the initial design of current post-mining land rehabilitation strategies. Our study proposes that a few common rainfall parameters can be combined and rated using arbitrary rainfall thresholds to characterise bioregional climate sensitivity relevant to the rehabilitation these landscapes. This approach included assessments of annual rainfall depth, average recurrence interval of prolonged low intensity rainfall, average recurrence intervals of short or prolonged high intensity events, median period without rain (or water-deficit) and standard deviation for this period in order to address climatic factors such as total water availability, seasonality and intensity - which were selected as potential proxies of both short- and long-term biological sensitivity to climate within the context of post-disturbance ecological development and recovery. Following our survey of available climate data, we derived site "climate sensitivity" indexes and compared the performance of 9 ongoing mine sites: Weipa, Mt. Isa and Cloncurry, Eromanga, Kidston, the Bowen Basin (Curragh), Tarong, North Stradbroke Island, and the Newnes Plateau. The sites were then ranked from most-to-least sensitive and compared with natural bioregional patterns of vegetation density using mean NDVI. It was determined that regular rainfall and relatively short periods of water-deficit were key characteristics of sites having less sensitivity to climate - as found among the relatively more temperate inland mining locations. Whereas, high rainfall variability, frequently occurring high intensity events, and (or) prolonged seasonal drought were primary indicators of sites having greater sensitivity to climate - as found among the semi-arid central-inland sites. Overall, the manner in which these climatic factors are identified and ultimately addressed by land managers and rehabilitation practitioners could be a key determinant of achievable success at given locations at the planning stages of rehabilitation design.
Kaercher, Thomas; Dietz, Jasna; Jacobi, Christina; Berz, Reinhold; Schneider, Holm
2015-09-01
X-linked hypohidrotic ectodermal dysplasia (XLHED) is the most common form of ectodermal dysplasia. Clinical characteristics include meibomian gland disorder and the resulting hyperevaporative dry eye. In this study, we evaluated meibography and ocular infrared thermography as novel methods to diagnose XLHED. Eight infants, 12 boys and 14 male adults with XLHED and 12 healthy control subjects were subjected to a panel of tests including the ocular surface disease index (OSDI), meibography and infrared thermography, non-invasive measurement of tear film break-up time (NIBUT) and osmolarity, Schirmer's test, lissamine green staining and fluorescein staining. Sensitivity and specificity were determined for single tests and selected test combinations. Meibography had 100% sensitivity and specificity for identifying XLHED. Infrared thermography, a completely non-invasive procedure, revealed a typical pattern for male subjects with XLHED. It was, however, less sensitive (86% for adults and 67% for children) than meibography or a combination of established routine tests. In adults, OSDI and NIBUT were the best single routine tests (sensitivity of 86% and 71%, respectively), whereas increased tear osmolarity appeared as a rather unspecific ophthalmic symptom. In children, NIBUT was the most convincing routine test (sensitivity of 91%). Meibography is the most reliable ophthalmic examination to establish a clinical diagnosis in individuals with suspected hypohidrotic ectodermal dysplasia, even before genetic test results are available. Tear film tests and ocular surface staining are less sensitive in children, but very helpful for estimating the severity of ocular surface disease in individuals with known XLHED.
Thibodeau, Eric L; August, Gerald J; Cicchetti, Dante; Symons, Frank J
2016-03-01
Preventive interventions that target high-risk youth, via one-size-fits-all approaches, have demonstrated modest effects in reducing rates of substance use. Recently, substance use researchers have recommended personalized intervention strategies. Central to these approaches is matching preventatives to characteristics of an individual that have been shown to predict outcomes. One compelling body of literature on person × environment interactions is that of environmental sensitivity theories, including differential susceptibility theory and vantage sensitivity. Recent experimental evidence has demonstrated that environmental sensitivity (ES) factors moderate substance abuse outcomes. We propose that ES factors may augment current personalization strategies such as matching based on risk factors/severity of problem behaviors (risk severity (RS)). Specifically, individuals most sensitive to environmental influence may be those most responsive to intervention in general and thus need only a brief-type or lower-intensity program to show gains, while those least sensitive may require more comprehensive or intensive programming for optimal responsiveness. We provide an example from ongoing research to illustrate how ES factors can be incorporated into prevention trials aimed at high-risk adolescents.
Geng, Haiqing; Chen, Fan; Wang, Zhiyuan; Liu, Jie; Xu, Weihua
2017-05-01
The purpose of this research is to establish an environmental management zoning for coal mining industry which is served as a basis for making environmental management policies. Based on the specific impacts of coal mining and regional characteristics of environment and resources, the ecological impact, water resources impact, and arable land impact are chose as the zoning indexes to construct the index system. The ecological sensitivity is graded into three levels of low, medium, and high according to analytical hierarchy processes and gray fixed weight clustering analysis, and the water resources sensitivity is divided into five levels of lower, low, medium, high, and higher according to the weighted sum of sub-indexes, while only the arable land sensitive zone was extracted on the basis of the ratio of arable land to the county or city. By combining the ecological sensitivity zoning and the water resources sensitive zoning and then overlapping the arable-sensitive areas, the mainland China is classified into six types of environmental management zones for coal mining except to the forbidden exploitation areas.
Kempe, Vera; Bublitz, Dennis; Brooks, Patricia J
2015-05-01
Is the observed link between musical ability and non-native speech-sound processing due to enhanced sensitivity to acoustic features underlying both musical and linguistic processing? To address this question, native English speakers (N = 118) discriminated Norwegian tonal contrasts and Norwegian vowels. Short tones differing in temporal, pitch, and spectral characteristics were used to measure sensitivity to the various acoustic features implicated in musical and speech processing. Musical ability was measured using Gordon's Advanced Measures of Musical Audiation. Results showed that sensitivity to specific acoustic features played a role in non-native speech-sound processing: Controlling for non-verbal intelligence, prior foreign language-learning experience, and sex, sensitivity to pitch and spectral information partially mediated the link between musical ability and discrimination of non-native vowels and lexical tones. The findings suggest that while sensitivity to certain acoustic features partially mediates the relationship between musical ability and non-native speech-sound processing, complex tests of musical ability also tap into other shared mechanisms. © 2014 The British Psychological Society.
Loi, Felice; Marlowe, Karl
2017-01-01
Seclusion is a last resort intervention for management of aggressive behavior in psychiatric settings. There is no current objective and practical decision-making instrument for seclusion use on psychiatric wards. Our aim was to test the predictive and discriminatory characteristics of the East London Modified-Broset (ELMB), to delineate its decision-making profile for seclusion of adult psychiatric patients, and second to benchmark it against the psychometric properties of the Broset Violence Checklist (BVC). ELMB, an 8-item modified version of the 6-item BVC, was retrospectively employed to evaluate the seclusion decision-making process on two Psychiatric Intensive Care Units (patients n = 201; incidents n = 2,187). Data analyses were carried out using multivariate regression and Receiver Operating Characteristic (ROC) curves. Predictors of seclusion were: physical violence toward staff/patients OR = 24.2; non-compliance with PRN (pro re nata) medications OR = 9.8; and damage to hospital property OR = 2.9. ROC analyses indicated that ELMB was significantly more accurate that BVC, with higher sensitivity, specificity, and positive likelihood ratio. Results were similar across gender. The ELMB is a sensitive and specific instrument that can be used to guide the decision-making process when implementing seclusion.
Loi, Felice; Marlowe, Karl
2017-01-01
Seclusion is a last resort intervention for management of aggressive behavior in psychiatric settings. There is no current objective and practical decision-making instrument for seclusion use on psychiatric wards. Our aim was to test the predictive and discriminatory characteristics of the East London Modified-Broset (ELMB), to delineate its decision-making profile for seclusion of adult psychiatric patients, and second to benchmark it against the psychometric properties of the Broset Violence Checklist (BVC). ELMB, an 8-item modified version of the 6-item BVC, was retrospectively employed to evaluate the seclusion decision-making process on two Psychiatric Intensive Care Units (patients n = 201; incidents n = 2,187). Data analyses were carried out using multivariate regression and Receiver Operating Characteristic (ROC) curves. Predictors of seclusion were: physical violence toward staff/patients OR = 24.2; non-compliance with PRN (pro re nata) medications OR = 9.8; and damage to hospital property OR = 2.9. ROC analyses indicated that ELMB was significantly more accurate that BVC, with higher sensitivity, specificity, and positive likelihood ratio. Results were similar across gender. The ELMB is a sensitive and specific instrument that can be used to guide the decision-making process when implementing seclusion. PMID:29046647
Yoo, Doo Han; Lee, Jae Shin
2016-07-01
[Purpose] This study examined the clinical usefulness of the clock drawing test applying Rasch analysis for predicting the level of cognitive impairment. [Subjects and Methods] A total of 187 stroke patients with cognitive impairment were enrolled in this study. The 187 patients were evaluated by the clock drawing test developed through Rasch analysis along with the mini-mental state examination of cognitive evaluation tool. An analysis of the variance was performed to examine the significance of the mini-mental state examination and the clock drawing test according to the general characteristics of the subjects. Receiver operating characteristic analysis was performed to determine the cutoff point for cognitive impairment and to calculate the sensitivity and specificity values. [Results] The results of comparison of the clock drawing test with the mini-mental state showed significant differences in according to gender, age, education, and affected side. A total CDT of 10.5, which was selected as the cutoff point to identify cognitive impairement, showed a sensitivity, specificity, Youden index, positive predictive, and negative predicive values of 86.4%, 91.5%, 0.8, 95%, and 88.2%. [Conclusion] The clock drawing test is believed to be useful in assessments and interventions based on its excellent ability to identify cognitive disorders.
NASA Technical Reports Server (NTRS)
Corless, L. D.; Blanken, C. L.
1983-01-01
A multi-phase program is being conducted to study, in a generic sense and through ground simulation, the effects of engine response, rotor inertia, rpm control, excess power, and vertical damping on specific maneuvers included in nap-of-the-Earth (NOE) operations. The helicopter configuration with an rpm-governed gas-turbine engine are considered. Handling-qualities-criteria data are considered in light of aspects peculiar to rotary-wing and NOE operations. The results of three moving-based piloted simulation studies are summarized and the frequency, characteristics of the helicopter thrust response which set it apart from other VTOL types are explained. Power-system response is affected by both the engine-governor response and the level of rotor inertia. However, results indicate that with unlimited power, variations in engine response can have a significant effect on pilot rating, whereas changes in rotor inertia, in general, do not. The results also show that any pilot interaction required to maintain proper control can significantly degrade handling qualities. Data for variations in vertical damping and collective sensitivity are compared with existing handling-qualities specifications, MIL-F-83300 and AGARD 577, and show a need for higher minimums for both damping and sensitivity for the bob-up task. Results for cases of limited power are also shown.
Kaur, Antarpreet; Edland, Steven D; Peavy, Guerry M
2018-01-01
To compare ability of 2 measures of delayed memory (word list, story paragraph) to discriminate Normal Control (NC) subjects from those with amnestic mild cognitive impairment (aMCI). Demographic, neuropsychological, and diagnostic data contributed by 34 Alzheimer's Disease Centers to the National Alzheimer's Coordinating Center characterized 2717 individuals with a diagnosis of either NC (n=2205) or aMCI (n=512). The Montreal Cognitive Assessment-Memory Index Score (MoCA-MIS) assessed delayed word recall, and the Craft Story 21, delayed story recall. Logistic regression and receiver operator characteristic curves controlling for age, sex, and education assessed the ability of each test to differentiate NCs from subjects with aMCI. The MoCA-MIS had significantly better sensitivity and specificity (area under the receiver operator characteristic curve 0.83 vs. 0.80, P=0.004). At sensitivity 80%, the specificity of the MoCA-MIS was 69.1%, compared with 62.8% for the Craft Story. These data suggest that the MoCA-MIS, a recall score from items within the MoCA, is better at discriminating NCs from subjects with aMCI than the Craft Story. Word recall may be an efficient alternative to paragraph recall for diagnostic screening within clinical practice and research settings.
Exercise-induced oxygen desaturation in COPD patients without resting hypoxemia.
Andrianopoulos, Vasileios; Franssen, Frits M E; Peeters, Jos P I; Ubachs, Tim J A; Bukari, Halah; Groenen, Miriam; Burtin, Chris; Vogiatzis, Ioannis; Wouters, Emiel F M; Spruit, Martijn A
2014-01-01
Exercise-induced oxygen desaturation (EID) is associated with increased risk of mortality in chronic obstructive pulmonary disease (COPD). Several screening tests have been proposed to predict EID, including FEV1, DLCO and baseline-SpO2. We aimed to validate a proposed cut-off of baseline-SpO2 ≤95% as simple screening procedure to predict EID during six-minute walk test (6MWT). In addition, we studied the prevalence and characteristics of patients exhibited EID to SpO2nadir ≤88%. 402 non-hypoxemic COPD patients performed 6MWT. Sensitivity and specificity of baseline SpO2 ≤95% as a cut-off to predict EID and determinants of EID were investigated. 158 patients (39%) exhibited EID. The sensitivity of baseline-SpO2 ≤95% to predict EID was 81.0%, specificity 49.2%, positive and negative predictive values were 50.8% and 80.0%, respectively. In a multivariate model, DLCO <50%, FEV1 <45%, PaO2 <10kPa, baseline-SpO2 <95%, and female sex were the strongest determinants of EID. Baseline oxygen saturation solely is inaccurate to predict EID. A combination of clinical characteristics (DLCO, FEV1, PaO2, baseline-SpO2, sex) increases the odds for EID in COPD. Copyright © 2013 Elsevier B.V. All rights reserved.
Trébucq, A; Guérin, N; Ali Ismael, H; Bernatas, J J; Sèvre, J P; Rieder, H L
2005-10-01
Djibouti, 1994 and 2001. To estimate the prevalence of tuberculosis (TB) and average annual risk of TB infection (ARTI) and trends, and to test a new method for calculations. Tuberculin surveys among schoolchildren and sputum smear-positive TB patients. Prevalence of infection was calculated using cut-off points, the mirror image technique, mixture analysis, and a new method based on the operating characteristics of the tuberculin test. Test sensitivity was derived from tuberculin reactions among TB patients and test specificity from a comparison of reaction size distributions among children with and without a BCG scar. The ARTI was estimated to lie between 2.6% and 3.1%, with no significant changes between 1994 and 2001. The close match of the distributions between children tested in 1994 and patients justifies the utilisation of the latter to determine test sensitivity. This new method gave very consistent estimates of prevalence of infection for any induration for values between 15 and 20 mm. Specificity was successfully determined for 1994, but not for 2001. Mixture analysis confirmed the estimates obtained with the new method. Djibouti has a high ARTI, and no apparent change over the observation time was found. Using operating test characteristics to estimate prevalence of infection looks promising.
Pantic, Igor; Dacic, Sanja; Brkic, Predrag; Lavrnja, Irena; Pantic, Senka; Jovanovic, Tomislav; Pekovic, Sanja
2014-10-01
This aim of this study was to assess the discriminatory value of fractal and grey level co-occurrence matrix (GLCM) analysis methods in standard microscopy analysis of two histologically similar brain white mass regions that have different nerve fiber orientation. A total of 160 digital micrographs of thionine-stained rat brain white mass were acquired using a Pro-MicroScan DEM-200 instrument. Eighty micrographs from the anterior corpus callosum and eighty from the anterior cingulum areas of the brain were analyzed. The micrographs were evaluated using the National Institutes of Health ImageJ software and its plugins. For each micrograph, seven parameters were calculated: angular second moment, inverse difference moment, GLCM contrast, GLCM correlation, GLCM variance, fractal dimension, and lacunarity. Using the Receiver operating characteristic analysis, the highest discriminatory value was determined for inverse difference moment (IDM) (area under the receiver operating characteristic (ROC) curve equaled 0.925, and for the criterion IDM≤0.610 the sensitivity and specificity were 82.5 and 87.5%, respectively). Most of the other parameters also showed good sensitivity and specificity. The results indicate that GLCM and fractal analysis methods, when applied together in brain histology analysis, are highly capable of discriminating white mass structures that have different axonal orientation.
Hoser, Mark J; Mansukoski, Hannu K; Morrical, Scott W; Eboigbodin, Kevin E
2014-01-01
Isothermal nucleic acid amplification technologies offer significant advantages over polymerase chain reaction (PCR) in that they do not require thermal cycling or sophisticated laboratory equipment. However, non-target-dependent amplification has limited the sensitivity of isothermal technologies and complex probes are usually required to distinguish between non-specific and target-dependent amplification. Here, we report a novel isothermal nucleic acid amplification technology, Strand Invasion Based Amplification (SIBA). SIBA technology is resistant to non-specific amplification, is able to detect a single molecule of target analyte, and does not require target-specific probes. The technology relies on the recombinase-dependent insertion of an invasion oligonucleotide (IO) into the double-stranded target nucleic acid. The duplex regions peripheral to the IO insertion site dissociate, thereby enabling target-specific primers to bind. A polymerase then extends the primers onto the target nucleic acid leading to exponential amplification of the target. The primers are not substrates for the recombinase and are, therefore unable to extend the target template in the absence of the IO. The inclusion of 2'-O-methyl RNA to the IO ensures that it is not extendible and that it does not take part in the extension of the target template. These characteristics ensure that the technology is resistant to non-specific amplification since primer dimers or mis-priming are unable to exponentially amplify. Consequently, SIBA is highly specific and able to distinguish closely-related species with single molecule sensitivity in the absence of complex probes or sophisticated laboratory equipment. Here, we describe this technology in detail and demonstrate its use for the detection of Salmonella.
Grimm, N. B.; Chacon, A.; Dahm, Clifford N.; Hostetler, S.W.; Lind, O.T.; Starkweather, P.L.; Wurtsbaugh, W.W.
1997-01-01
Variability and unpredictability are characteristics of the aquatic ecosystems, hydrological patterns and climate of the largely dryland region that encompasses the Basin and Range, American Southwest and western Mexico. Neither hydrological nor climatological models for the region are sufficiently developed to describe the magnitude or direction of change in response to increased carbon dioxide; thus, an attempt to predict specific responses of aquatic ecosystems is premature. Instead, we focus on the sensitivity of rivers, streams, springs, wetlands, reservoirs, and lakes of the region to potential changes in climate, especially those inducing a change in hydrological patterns such as amount, timing and predictability of stream flow. The major sensitivities of aquatic ecosystems are their permanence and even existence in the face of potential reduced net basin supply of water, stability of geomorphological structure and riparian ecotones with alterations in disturbance regimes, and water quality changes resulting from a modified water balance. In all of these respects, aquatic ecosystems of the region are also sensitive to the extensive modifications imposed by human use of water resources, which underscores the difficulty of separating this type of anthropogenic change from climate change. We advocate a focus in future research on reconstruction and analysis of past climates and associated ecosystem characteristics, long-term studies to discriminate directional change vs. year to year variability (including evidence of aquatic ecosystem responses or sensitivity to extremes), and studies of ecosystems affected by human activity. ?? 1997 by John Wiley & Sons, Ltd.
Vagal Flexibility: A Physiological Predictor of Social Sensitivity
Muhtadie, Luma; Akinola, Modupe; Koslov, Katrina; Mendes, Wendy Berry
2015-01-01
This research explores vagal flexibility— dynamic modulation of cardiac vagal control—as an individual-level physiological index of social sensitivity. In 4 studies, we test the hypothesis that individuals with greater cardiac vagal flexibility, operationalized as higher cardiac vagal tone at rest and greater cardiac vagal withdrawal (indexed by a decrease in respiratory sinus arrhythmia) during cognitive or attentional demand, perceive social-emotional information more accurately and show greater sensitivity to their social context. Study 1 sets the foundation for this investigation by establishing that vagal flexibility can be elicited consistently in the laboratory and reliably over time. Study 2 demonstrates that vagal flexibility has different associations with psychological characteristics than does vagal tone, and that these characteristics are primarily social in nature. Study 3 links individual differences in vagal flexibility with accurate detection of social and emotional cues depicted in still facial images. Study 4 demonstrates that individuals with greater vagal flexibility respond to dynamic social feedback in a more context-sensitive manner than do individuals with less vagal flexibility. Specifically, compared with their less flexible counterparts, individuals with greater vagal flexibility, when assigned to receive negative social feedback, report more shame, show more pronounced blood pressure responses, and display less sociable behavior, but when receiving positive social feedback display more sociable behavior. Taken together, these findings suggest that vagal flexibility is a useful individual difference physiological predictor of social sensitivity, which may have implications for clinical, developmental, and health psychologists. PMID:25545841
Calcium sensitivity of residual force enhancement in rabbit skinned fibers.
Joumaa, V; Herzog, W
2014-08-15
Isometric force after active stretch of muscles is higher than the purely isometric force at the corresponding length. This property is termed residual force enhancement. Active force in skeletal muscle depends on calcium attachment characteristics to the regulatory proteins. Passive force has been shown to influence calcium attachment characteristics, specifically the sarcomere length dependence of calcium sensitivity. Since one of the mechanisms proposed to explain residual force enhancement is the increase in passive force that results from engagement of titin upon activation and stretch, our aim was to test if calcium sensitivity of residual force enhancement was different from that of its corresponding purely isometric contraction and if such a difference was related to the molecular spring titin. Force-pCa curves were established in rabbit psoas skinned fibers for reference and residual force-enhanced states at a sarcomere length of 3.0 μm 1) in a titin-intact condition, 2) after treatment with trypsin to partially eliminate titin, and 3) after treatment with trypsin and osmotic compression with dextran T-500 to decrease the lattice spacing in the absence of titin. The force-pCa curves of residual force enhancement were shifted to the left compared with their corresponding controls in titin-intact fibers, indicating increased calcium sensitivity. No difference in calcium sensitivity was observed between reference and residual force-enhanced contractions in trypsin-treated and osmotically compressed trypsin-treated fibers. Furthermore, calcium sensitivity after osmotic compression was lower than that observed for residual force enhancement in titin-intact skinned fibers. These results suggest that titin-based passive force regulates the increase in calcium sensitivity of residual force enhancement by a mechanism other than reduction of the myofilament lattice spacing. Copyright © 2014 the American Physiological Society.
Larras, Floriane; Bouchez, Agnès; Rimet, Frédéric; Montuelle, Bernard
2012-01-01
Although benthic diatoms are widely used in ecological studies of aquatic systems, there is still a dearth of data concerning species sensitivities towards several contaminants. Within the same community, different species may respond differently depending on their physiological and ecological characteristics. This lack of knowledge makes specific appropriate risk assessment impossible. To find out whether species sensitivity distribution (SSD) could be used to estimate the risk of herbicide toxicity for diatoms, we need to know whether their sensitivity depends on their physiological and ecological characteristics. We carried out single-species bioassays on 11 diatom species exposed to 8 herbicides. Dose-responses relationships were used to extrapolate the Effective Concentration 5 (EC5) and the Effective Concentration 50 (EC50) for each exposure. These data were used to fit a SSD curve for each herbicide, and to determine the Hazardous concentration 5 (HC5) and 50 (HC50). Our results revealed a high level of variability of the sensitivity in the set of species tested. For photosystem-II inhibitor (PSII) herbicides, diatoms species displayed a typical grouping of sensitivity levels consistent with their trophic mode and their ecological guild. N-heterotroph and “motile” guild species were more tolerant of PSII inhibitors, while N-autotroph and “low profile” guild species were more sensitive. Comprehensive SSD curves were obtained for 5 herbicides, but not for sulfonylurea herbicides or for dimetachlor, which had toxicity levels that were below the range of concentration tested. The SSD curves provided the following ranking of toxicity: diuron> terbutryn> isoproturon> atrazine> metolachlor. The HC that affected 5% of the species revealed that, even at the usual environmental concentrations of herbicides, diatom assemblages could be affected, especially by isoproturon, terbutryn, and diuron. PMID:22952981
[Studies on HPLC fingerprint chromatogram of Folium Fici Microcarpa].
Fang, Zhi-Jian; Dai, Zhen; Li, Shu-Yuan
2008-10-01
To establish a sensitive and specific method for quality control of Folium Fici Microcarpa, HPLC method was applied for studies on the fingerprint chromatogram of Folium Fici Microcarpa. Isovitexin was used as reference substance to evaluate the chromatogram of 10 samples from different regions and 12 samples collected in different months. The result revealed that all the chromatographic peaks were seperated efficiently. There were 17 common peaks showed in the fingerprint chromatogram. The method of fingerprint chromatogram with characteristic and specificity will be used to identify the quality and evaluate different origins and collection period of Folium Fici Microcarpa.
Watanabe, Yoshiyuki; Kim, Hyun Soo; Castoro, Ryan J; Chung, Woonbok; Estecio, Marcos R H; Kondo, Kimie; Guo, Yi; Ahmed, Saira S; Toyota, Minoru; Itoh, Fumio; Suk, Ki Tae; Cho, Mee-Yon; Shen, Lanlan; Jelinek, Jaroslav; Issa, Jean-Pierre J
2009-06-01
Aberrant DNA methylation is an early and frequent process in gastric carcinogenesis and could be useful for detection of gastric neoplasia. We hypothesized that methylation analysis of DNA recovered from gastric washes could be used to detect gastric cancer. We studied 51 candidate genes in 7 gastric cancer cell lines and 24 samples (training set) and identified 6 for further studies. We examined the methylation status of these genes in a test set consisting of 131 gastric neoplasias at various stages. Finally, we validated the 6 candidate genes in a different population of 40 primary gastric cancer samples and 113 nonneoplastic gastric mucosa samples. Six genes (MINT25, RORA, GDNF, ADAM23, PRDM5, MLF1) showed frequent differential methylation between gastric cancer and normal mucosa in the training, test, and validation sets. GDNF and MINT25 were most sensitive molecular markers of early stage gastric cancer, whereas PRDM5 and MLF1 were markers of a field defect. There was a close correlation (r = 0.5-0.9, P = .03-.001) between methylation levels in tumor biopsy and gastric washes. MINT25 methylation had the best sensitivity (90%), specificity (96%), and area under the receiver operating characteristic curve (0.961) in terms of tumor detection in gastric washes. These findings suggest MINT25 is a sensitive and specific marker for screening in gastric cancer. Additionally, we have developed a new method for gastric cancer detection by DNA methylation in gastric washes.
Castinetti, F; Morange, I; Dufour, H; Jaquet, P; Conte-Devolx, B; Girard, N; Brue, T
2007-09-01
Corticotropin-releasing hormone (CRH)-stimulated petrosal sinus sampling is currently the gold standard method for the differential diagnosis between pituitary and ectopic ACTH-dependent Cushing's syndrome. Our objective was to determine sensitivity and specificity of desmopressin test during petrosal sinus sampling. Forty-three patients had petrosal sinus sampling because of the lack of visible adenoma on magnetic resonance imaging (MRI) and/or because of discordant cortisol response to high-dose dexamethasone suppression test. ACTH sampling was performed in an antecubital vein, right and left petrosal sinuses, then at each location 5 and 10 min after injection of desmopressin. Diagnosis was based on the ACTH ratio between petrosal sinus and humeral vein ACTH after desmopressin test. Diagnosis was confirmed after surgery. A receiver operating characteristics curve was used to determine optimal sensitivity and specificity. Thirty-six patients had Cushing's disease (CD) and seven had ectopic ACTH secretion. A ratio > 2 after desmopressin was found in 35 of the 36 cases of CD (sensitivity: 95%). A ratio < or = 2 was found in the seven patients with ectopic ACTH secretion (specificity: 100%). Sinus sampling was ineffective in determining the left or right localization of the adenoma (sensitivity = 50%). No major adverse effects were observed during or after the procedure. Desmopressin test during petrosal sinus sampling is a safe and effective diagnostic procedure in ACTH-dependent Cushing's syndrome. It thus represents a valuable alternative to CRH.
Morris, R K; Riley, R D; Doug, M; Deeks, J J
2012-01-01
Objective To determine the diagnostic accuracy of two “spot urine” tests for significant proteinuria or adverse pregnancy outcome in pregnant women with suspected pre-eclampsia. Design Systematic review and meta-analysis. Data sources Searches of electronic databases 1980 to January 2011, reference list checking, hand searching of journals, and contact with experts. Inclusion criteria Diagnostic studies, in pregnant women with hypertension, that compared the urinary spot protein to creatinine ratio or albumin to creatinine ratio with urinary protein excretion over 24 hours or adverse pregnancy outcome. Study characteristics, design, and methodological and reporting quality were objectively assessed. Data extraction Study results relating to diagnostic accuracy were extracted and synthesised using multivariate random effects meta-analysis methods. Results Twenty studies, testing 2978 women (pregnancies), were included. Thirteen studies examining protein to creatinine ratio for the detection of significant proteinuria were included in the multivariate analysis. Threshold values for protein to creatinine ratio ranged between 0.13 and 0.5, with estimates of sensitivity ranging from 0.65 to 0.89 and estimates of specificity from 0.63 to 0.87; the area under the summary receiver operating characteristics curve was 0.69. On average, across all studies, the optimum threshold (that optimises sensitivity and specificity combined) seems to be between 0.30 and 0.35 inclusive. However, no threshold gave a summary estimate above 80% for both sensitivity and specificity, and considerable heterogeneity existed in diagnostic accuracy across studies at most thresholds. No studies looked at protein to creatinine ratio and adverse pregnancy outcome. For albumin to creatinine ratio, meta-analysis was not possible. Results from a single study suggested that the most predictive result, for significant proteinuria, was with the DCA 2000 quantitative analyser (>2 mg/mmol) with a summary sensitivity of 0.94 (95% confidence interval 0.86 to 0.98) and a specificity of 0.94 (0.87 to 0.98). In a single study of adverse pregnancy outcome, results for perinatal death were a sensitivity of 0.82 (0.48 to 0.98) and a specificity of 0.59 (0.51 to 0.67). Conclusion The maternal “spot urine” estimate of protein to creatinine ratio shows promising diagnostic value for significant proteinuria in suspected pre-eclampsia. The existing evidence is not, however, sufficient to determine how protein to creatinine ratio should be used in clinical practice, owing to the heterogeneity in test accuracy and prevalence across studies. Insufficient evidence is available on the use of albumin to creatinine ratio in this area. Insufficient evidence exists for either test to predict adverse pregnancy outcome. PMID:22777026
A novel class of Saccharomyces cerevisiae mutants specifically UV-sensitive to "petite" induction.
Moustacchi, E; Perlman, P S; Mahler, H R
1976-11-17
A mutant of Saccharomyces cerevisiae has been isolated which, though exhibiting a normal response to nuclear genetic damage by ultraviolet light (UV), is more sensitive than its wild type specifically in the production of the cytoplasmic (rho-) mutation by this agent. Some of the features of this mutation which has been designated uvsrho 5 are: i) The mutation is recessive, it exhibits a Mendelian, and hence presumably nuclear, pattern of segregation, but manifests its effects specifically and pleiotropically on mitochondrial functions. ii) Mutant cells resemble their wild type parents in a) growth characteristics on glucose; b) in their UV induced dose response to lethality or nuclear mutation and c) the ability of their mitochondrial genome, upon mating with appropriate testers, of transmitting and recombining various markers, albeit with enhanced efficiency. Similarly, d) they are able to modulate the expression of mitochondrial mutagenesis by ethidium bromide. Thus their mitochondrial DNA appears genetically as competent as that of the wild type. iii) Mutant cells differ from their wild type parents in a) growth characteristics on glycerol; b) susceptibility to induction of the mitochondrial (rho-) mutation by various mutagens, in that the rate of spontaneous mutation is slightly and that by UV is significantly enhanced, whild that by ethidium bromide is greatly diminished. Conversely, c) modulating influences resulting in the repair of initial damage are diminished fro UV and stimulated in the case of Berenil. iv) The amount of mitochondrial DNA per cell appears elevated in the mutant, relative to wild type, and its rate of degradation subsequent to a mutagenic exposure to either UV or ethidium bromide is diminished. v) A self-consistent scheme to account for this and all other information so far available for the induction and modulation of the (rho-) mutation is presented. In a previous study it was shown that some nuclear mutants of Saccharomyces cerevisiae, more sensitive to lethal damage induced by ultraviolet light (rad) than their parent wild type (RAD), also exhibit a concomitant modification in sensitivity to both nuclear and cytoplasmic genetic damage (Moustacchi, 1971). However, another class of rad mutants respond to the induction of the cytoplasmic "petite" also designated as rho- (or rho-) mutation by UV in a manner indistinguishable from that of the RAD strain. One possible interpretation of this last observation is that some of the steps in the expression of the UV damage on mitochondrial (mt)DNA may be governed by other nuclear and cytoplasmic genetic determinants, the products of which may then act specifically on mitochondrial lesions. If this assumption is correct, it should be possible to find mutants with a normal response to nuclear damage but specifically UV-sensitive towards induction of (rho-)...
Bruner, L H; Carr, G J; Harbell, J W; Curren, R D
2002-06-01
An approach commonly used to measure new toxicity test method (NTM) performance in validation studies is to divide toxicity results into positive and negative classifications, and the identify true positive (TP), true negative (TN), false positive (FP) and false negative (FN) results. After this step is completed, the contingent probability statistics (CPS), sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) are calculated. Although these statistics are widely used and often the only statistics used to assess the performance of toxicity test methods, there is little specific guidance in the validation literature on what values for these statistics indicate adequate performance. The purpose of this study was to begin developing data-based answers to this question by characterizing the CPS obtained from an NTM whose data have a completely random association with a reference test method (RTM). Determining the CPS of this worst-case scenario is useful because it provides a lower baseline from which the performance of an NTM can be judged in future validation studies. It also provides an indication of relationships in the CPS that help identify random or near-random relationships in the data. The results from this study of randomly associated tests show that the values obtained for the statistics vary significantly depending on the cut-offs chosen, that high values can be obtained for individual statistics, and that the different measures cannot be considered independently when evaluating the performance of an NTM. When the association between results of an NTM and RTM is random the sum of the complementary pairs of statistics (sensitivity + specificity, NPV + PPV) is approximately 1, and the prevalence (i.e., the proportion of toxic chemicals in the population of chemicals) and PPV are equal. Given that combinations of high sensitivity-low specificity or low specificity-high sensitivity (i.e., the sum of the sensitivity and specificity equal to approximately 1) indicate lack of predictive capacity, an NTM having these performance characteristics should be considered no better for predicting toxicity than by chance alone.
Ali, Innocent M; Bigoga, Jude D; Forsah, Dorothy A; Cho-Ngwa, Fidelis; Tchinda, Vivian; Moor, Vicky Ama; Fogako, Josephine; Nyongalema, Philomena; Nkoa, Theresa; Same-Ekobo, Albert; Mbede, Joseph; Fondjo, Etienne; Mbacham, Wilfred F; Leke, Rose G F
2016-01-20
All suspected cases of malaria should receive a diagnostic test prior to treatment with artemisinin-based combinations based on the new WHO malaria treatment guidelines. This study compared the accuracy and some operational characteristics of 22 different immunochromatographic antigen capture point-of- malaria tests (RDTs) in Cameroon to inform test procurement prior to deployment of artemisinin-based combinations for malaria treatment. One hundred human blood samples (50 positive and 50 negative) collected from consenting febrile patients in two health centres at Yaoundé were used for evaluation of the 22 RDTs categorized as "Pf Only" (9) or "Pf + PAN" (13) based on parasite antigen captured [histidine rich protein II (HRP2) or lactate dehydrogenase (pLDH) or aldolase]. RDTs were coded to blind technicians performing the tests. The sensitivity, specificity, and predictive values of the positive and negative tests (PPV and NPV) as well as the likelihood ratios were assessed. The reliability and some operational characteristics were determined as the mean values from two assessors, and the Cohen's kappa statistic was then used to compare agreement. Light microscopy was the referent. Of all RDTs tested, 94.2 % (21/22) had sensitivity values greater than 90% among which 14 (63.6%) were 'Pf + PAN' RDTs. The specificity was generally lower than the sensitivity for all RDTs and poorer for "Pf Only" RDTs. The predictive values and likelihood ratios were better for non-HRP2 analytes for "Pf + PAN" RDTs. The Kappa value for most of the tests obtained was around 67% (95% CI 50-69%), corresponding to a moderate agreement. Overall, 94.2% (21/22) of RDTs tested had accuracy within the range recommended by the WHO, while one performed poorly, below acceptable levels. Seven "Pf + PAN" and 3 "Pf Only" RDTs were selected for further assessment based on performance characteristics. Harmonizing RDT test presentation and procedures would prevent mistakes of test performance and interpretation.
Westwood, Marie E; Raatz, Heike D I; Misso, Kate; Burgers, Laura; Redekop, Ken; Lhachimi, Stefan K; Armstrong, Nigel; Kleijnen, Jos
2013-05-01
To assess the diagnostic performance of dual-source cardiac (DSC) computed tomography (CT) newer-generation CT instruments for identifying anatomically significant coronary artery disease (CAD) in patients who are difficult to image by using 64-section CT. A literature search comprised bibliographic databases (January 1, 2000, to March 22, 2011, with a pragmatic update on September 6, 2012), trial registries, and conference proceedings. Only studies using invasive coronary angiography as reference standard were included. Risk of bias was assessed (QUADAS-2). Results were stratified according to patient group on the basis of clinical characteristics. Summary estimates of sensitivity and specificity of DSC CT for detecting 50% or greater arterial stenosis were calculated by using a bivariate summary receiver operating characteristic or random-effects model. Twenty-five studies reported accuracy of DSC CT for diagnosing CAD in difficult to image patients; in 22 studies, one of two CT units of the same manufacturer (Somatom Definition or Somatom Definition Flash) was used, and in the remaining three, a different CT unit of another manufacturer (Aquilion One) was used. The pooled, per-patient estimates of sensitivity were 97.7% (95% confidence interval [CI]: 88.0%, 99.9%) and 97.7% (95% CI: 93.2%, 99.3%) for patients with arrhythmias and high heart rates, respectively. The corresponding pooled estimates of specificity were 81.7% (95% CI: 71.6%, 89.4%) and 86.3% (95% CI: 80.2%, 90.7%), respectively. All data were acquired by using Somatom Definition. In two studies with Somatom and one study with Aquilion One, sensitivity estimates of 90% or greater were reported in patients with previous stent implantations; specificities were 81.7% and 89.5% for Somatom and 81.0% for Aquilion One. In patients with high coronary calcium scores, previous bypass grafts, or obesity, only per-segment or per-artery data were available. Sensitivity estimates remained high (>90% in all but one study), and specificities ranged from 79.1% to 100%. All data were acquired by using Somatom Definition. DSC CT may be sufficiently accurate to diagnose clinically significant CAD in some or all difficult to image patients. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.13121136/-/DC1. © RSNA, 2013.
Loewen, Nils A; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Greenfield, David S; Schuman, Joel S; Varma, Rohit; Huang, David
2015-09-01
To improve the diagnostic power for glaucoma by combining measurements of peripapillary nerve fibre layer (NFL), macular ganglion cell complex (GCC) and disc variables obtained with Fourier-domain optical coherence tomography (FD-OCT) into the glaucoma structural diagnostic index (GSDI). In this observational, cross-sectional study of subjects from the Advanced Imaging of Glaucoma Study, GCC and NFL of healthy and perimetrical glaucoma subjects from four major academic referral centres of the Advanced Imaging of Glaucoma Study were mapped with the RTVue FD-OCT. Global loss volume and focal loss volume parameters were defined using NFL and GCC normative reference maps. Optimal weights for NFL, GCC and disc variables were combined using multivariate logistic regression to build the GSDI. Glaucoma severity was classified using the Enhanced Glaucoma Staging System (GSS2). Diagnostic accuracy was assessed by sensitivity, specificity and the area under the receiver operator characteristic curve (AUC). We analysed 118 normal eyes of 60 subjects, 236 matched eyes of 166 subjects with perimetrical glaucoma, and 105 eyes from a healthy reference group of 61 subjects. The GSDI included composite overall thickness and focal loss volume with weighted NFL and GCC components, as well as the vertical cup-to-disc ratio. The AUC of 0.922 from leave-one-out cross validation was better than the best component variable alone (p=0.047). The partial AUC in the high specificity region was also better (p=0.01), with a sensitivity of 69% at 99% specificity, and a sensitivity of 80.3% at 95% specificity. For GSS2 stages 3-5 the sensitivity was 98% at 99% specificity, and 100% at 95% specificity. Combining structural measurements of GCC, NFL and disc variables from FD-OCT created a GSDI that improved the accuracy for glaucoma diagnosis. NCT01314326. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Ragi, K. B.; Patel, R.
2015-12-01
A great deal of studies focused on deforestation scenarios in the tropical rainforests. Though all these efforts are useful in the understanding of its response to climate, the systematic understanding of uncertainties in representation of physical processes related to vegetation through sensitivity studies is imperative antecedently to understand the real role of vegetation in changing the climate. It is understood that the dense vegetation fluxes energy and moisture to the atmosphere. But, how much a specific process/a group of processes in the surface conditions of a specific area helps flux energy, moisture and tracers is unknown due to lack of process sensitivity studies and uncertain due to malfunctioning of processes. In this presentation, we have found a faulty parameterization, through process sensitivity studies, that would abet in energy and moisture fluxes to the atmosphere. The model we have employed is the Common Land Model2014. The area we have chosen is the Congolese rainforest. We have discovered the flaw in the leaf boundary layer resistance (LBLR), through sensitivity studies in the LSMs, especially in the dense forest regions. This LBLR is over-parameterized with constant heat transfer coefficient and characteristic dimension of leaves; and friction velocity. However, it is too scant because of overlooking of significant complex physics of turbulence and canopy roughness boundary layer to function it realistically. Our sensitivity results show the deficiency of this process and we have formulated canopy boundary layer resistance, instead of LBLR, with depending variables such as LAI, roughness length, vegetation temperature using appropriate thermo-fluid dynamical principles. We are running the sensitivity experiments with new formulations for setting the parameter values for the data not available so far. This effort would lead to better physics for the land-use change studies and demand for the retrieval of new parameters from satellite/field experiments such as leaf mass per area and specific heat capacity of vegetation.
Hermann, Laura L; Thaisomboonsuk, Butsaya; Poolpanichupatam, Yongyuth; Jarman, Richard G; Kalayanarooj, Siripen; Nisalak, Ananda; Yoon, In-Kyu; Fernandez, Stefan
2014-10-01
Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens. The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7. The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.
Bhattacharyya, Agnihotri; Mukherjee, Shuvankar; Chatterjee, Chitra; Dasgupta, Samir
2013-04-01
Integrated management of childhood illness (IMNCI) is already operational in many states of India, but there are only limited studies in Indian scenario comparing its validity and reliability with the decisions of pediatricians. Aims and. To assess the validity and reliability of the IMNCI algorithm with provisional diagnosis of senior pediatricians for each IMNCI classifications. The present study is done with all the young infants between 0-2 months presented during the study period with a fresh episode of illness to test the validity and reliability of the algorithm in comparison to provisional diagnoses of senior pediatricians. The study was done in a tertiary care hospital. Validity characteristics such as sensitivity, specificity, positive predictive value, negative predictive value, and reliability characteristics such as percent agreement and Kappa were assessed for individual IMNCI classifications. The sensitivity of possible serious bacterial infection, local bacterial infection, jaundice, no dehydration and possible serious bacterial infection, not able to feed were 88.89, 14.29, 66.67, 25 and 44.44% respectively. The specificities for the same conditions were 71.72, 99.09, 99.07, 94.50 and 86.87%. Percent agreements for similar conditions were 74, 94, 97, 90 and 80% respectively and the Kappa ratios were 0.38, 0.20, 0.73, 0.19 and 0.29 respectively. It could be concluded that IMNCI is quite a sensitive strategy and could identify severe illnesses of young infants requiring referral to higher facility. Further studies, particularly in primary health care setting, are required.
Inferior colliculus contributions to phase encoding of stop consonants in an animal model
Warrier, Catherine M; Abrams, Daniel A; Nicol, Trent G; Kraus, Nina
2011-01-01
The human auditory brainstem is known to be exquisitely sensitive to fine-grained spectro-temporal differences between speech sound contrasts, and the ability of the brainstem to discriminate between these contrasts is important for speech perception. Recent work has described a novel method for translating brainstem timing differences in response to speech contrasts into frequency-specific phase differentials. Results from this method have shown that the human brainstem response is surprisingly sensitive to phase-differences inherent to the stimuli across a wide extent of the spectrum. Here we use an animal model of the auditory brainstem to examine whether the stimulus-specific phase signatures measured in human brainstem responses represent an epiphenomenon associated with far field (i.e., scalp-recorded) measurement of neural activity, or alternatively whether these specific activity patterns are also evident in auditory nuclei that contribute to the scalp-recorded response, thereby representing a more fundamental temporal processing phenomenon. Responses in anaesthetized guinea pigs to three minimally-contrasting consonant-vowel stimuli were collected simultaneously from the cortical surface vertex and directly from central nucleus of the inferior colliculus (ICc), measuring volume conducted neural activity and multiunit, near-field activity, respectively. Guinea pig surface responses were similar to human scalp-recorded responses to identical stimuli in gross morphology as well as phase characteristics. Moreover, surface recorded potentials shared many phase characteristics with near-field ICc activity. Response phase differences were prominent during formant transition periods, reflecting spectro-temporal differences between syllables, and showed more subtle differences during the identical steady-state periods. ICc encoded stimulus distinctions over a broader frequency range, with differences apparent in the highest frequency ranges analyzed, up to 3000 Hz. Based on the similarity of phase encoding across sites, and the consistency and sensitivity of response phase measured within ICc, results suggest that a general property of the auditory system is a high degree of sensitivity to fine-grained phase information inherent to complex acoustical stimuli. Furthermore, results suggest that temporal encoding in ICc contributes to temporal features measured in speech-evoked scalp-recorded responses. PMID:21945200
Thanachartwet, Vipa; Wattanathum, Anan; Oer-areemitr, Nittha; Jittmittraphap, Akanitt; Sahassananda, Duangjai; Monpassorn, Chalida; Surabotsophon, Manoon; Desakorn, Varunee
2016-02-01
Dengue is the most common mosquito-borne viral disease in humans. However, the sensitivities of warning signs (WSs) for identifying severe dengue in adults are low, and the utility of lactate levels for identifying severe dengue in adults has not been verified. Therefore, we aimed to evaluate the diagnostic accuracy of using peripheral venous lactate levels (PVL), as well as WSs established by the World Health Organization, for identifying severe dengue. We prospectively evaluated individuals hospitalized for dengue who were admitted to the Hospital for Tropical Diseases in Thailand between May 2013 and January 2015. Blood samples to evaluate PVL levels were collected at admission and every 24 h until the patient exhibited a body temperature of <37.8 °C for at least 24 h. Data were recorded on a pre-defined case report form, including baseline characteristics, clinical parameters, and laboratory findings. Among 125 patients with confirmed dengue, 105 (84.0%) patients had non-severe dengue, and 20 (16.0%) patients had severe dengue. The presence of clinical fluid accumulation as a WS provided high sensitivity (75.0%, 95% confidence interval [CI]: 50.9-91.3%) and specificity (90.5%, 95% CI: 83.2-95.3%). The PVL level at admission was used to evaluate its diagnostic value, and receiver operating characteristic curve analysis revealed an area under the curve of 0.84 for identifying severe dengue. At the optimal cutoff value (PVL: 2.5 mmol/L), the sensitivity and specificity were 65.0% (95% CI: 40.8-84.6%) and 96.2% (95% CI: 90.5-99.0%), respectively. A combined biomarker comprising clinical fluid accumulation and/or PVL of ≥2.5 mmol/L provided the maximum diagnostic accuracy for identifying severe dengue, with a sensitivity of 90.0% (95% CI: 68.3-98.8%) and a specificity of 87.6% (95% CI: 79.8-93.2%). Clinical fluid accumulation and/or PVL may be used as a diagnostic biomarker of severe dengue among adults. This biomarker may facilitate early recognition and timely treatment of patients with severe dengue, which may reduce dengue-related mortality and hospital burden.
Dose-response characteristics of an amorphous silicon EPID.
Winkler, Peter; Hefner, Alfred; Georg, Dietmar
2005-10-01
Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetric properties of an amorphous silicon EPID (Elekta IVIEWGT) with respect to three photon beam qualities: 6, 10, and 25 MV. The EPID showed an excellent temporal stability on short term as well as on long term scales. The stability throughout the day was strongly influenced by warming up, which took several hours and affected EPID response by 2.5%. Ghosting effects increased the sensitivity of the EPID. They became more pronounced with decreasing time intervals between two exposures as well as with increasing dose. Due to ghosting, changes in pixel sensitivity amounted up to 16% (locally) for the 25 MV photon beam. It was observed that the response characteristics of our EPID depended on dose as well as on dose rate. Doubling the dose rate increased the EPID sensitivity by 1.5%. This behavior was successfully attributed to a dose per frame effect, i.e., a nonlinear relationship between the EPID signal and the dose which was delivered to the panel between two successive readouts. The sensitivity was found to vary up to 10% in the range of 1 to 1000 monitor units. This variation was governed by two independent effects. For low doses, the EPID signal was reduced due to the linac's changing dose rate during startup. Furthermore, the detector reading was influenced by intrabeam variations of EPID sensitivity, namely, an increase of detector response during uniform exposure. For the beam qualities which were used, the response characteristics of the EPID did not depend on energy. Differences in relative dose-response curves resulted from energy dependent temporal output characteristics of the accelerator. If ghosting is prevented from affecting the results and all dose-response effects are properly corrected for, the EPID signal becomes independent of dose rate, dose, and exposure time.
De Souza, Aglecio Luiz; Batista, Gisele Almeida; Alegre, Sarah Monte
2017-01-01
We compare spectral analysis of photoplethysmography (PTG) with insulin resistance measured by the hyperinsulinemic euglycemic clamp (HEC) technique. A total of 100 nondiabetic subjects, 43 men and 57 women aged 20-63years, 30 lean, 42 overweight and 28 obese were enrolled in the study. These patients underwent an examination with HEC, and an examination with the PTG spectral analysis and calculation of the PTG Total Power (PTG-TP). Receiver-operating characteristic (ROC) curves were constructed to determine the specificity and sensitivity of PTG-TP in the assessment of insulin resistance. There is a moderate correlation between insulin sensitivity (M-value) and PTG-TP (r=- 0.64, p<0.0001). The ROC curves showed that the most relevant cutoff to the whole study group was a PTG-TP>406.2. This cut-off had a sensitivity=95.7%, specificity =84,4% and the area under the ROC curve (AUC)=0.929 for identifying insulin resistance. All AUC ROC curve analysis were significant (p<0.0001). The use of the PTG-TP marker measured from the PTG spectral analysis is a useful tool in screening and follow up of IR, especially in large-scale studies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Kulthanan, Kanokvalai; Chularojanamontri, Leena; Manapajon, Araya; Nuchkull, Piyavadee
2011-12-01
The clinical role of house dust mite (HDM) in atopic dermatitis (AD) is still controversial. The aim of the study is to assess the prevalence, clinical relevance and characteristics of adult-onset AD patients with positive skin prick tests (SPT) to mites. The case record forms of adult-onset AD patients who underwent SPT at the Skin Allergy Clinic, Siriraj Hospital were reviewed. Forty-one of 62 patients (66.1%) had positive SPT to mites. The frequency of intrinsic AD among adult-onset AD was 4.8% (3/62). SPT to HDM tended to be positive in patients who had personal or family history of atopy, positive SPT to several specific antigens or who presented with elevated serum IgE, chelitis, recurrent conjunctivitis and perifollicular accentuation, respectively. CONCLUSION The prevalence of adult-onset AD patients with mite sensitivity was high. There were some notable features that tended to be present in mite sensitive adult-onset AD patients.
McPhail, Mark J W; Farne, Hugo; Senvar, Naz; Wendon, Julia A; Bernal, William
2016-04-01
Several prognostic factors are used to identify patients with acute liver failure (ALF) who require emergency liver transplantation. We performed a meta-analysis to determine the accuracy of King's College criteria (KCC) versus the model for end-stage liver disease (MELD) scores in predicting hospital mortality among patients with ALF. We performed a systematic search of the literature for articles published from 2001 through 2015 that compared the accuracy of the KCC with MELD scores in predicting hospital mortality in patients with ALF. We identified 23 studies (comprising 2153 patients) and assessed the quality of data, and then performed a meta-analysis of pooled sensitivity and specificity values, diagnostic odds ratios (DORs), and summary receiver operating characteristic curves. Subgroups analyzed included study quality, era, location (Europe vs non-Europe), and size; ALF etiology (acetaminophen-associated ALF [AALF] vs nonassociated [NAALF]); and whether or not the study included patients who underwent liver transplantation and if the study center was also a transplant center. The DOR for the KCC was 5.3 (95% confidence interval [CI], 3.7-7.6; 57% heterogeneity) and the DOR for MELD score was 7.0 (95% CI, 5.1-9.7; 48% heterogeneity), so the MELD score and KCC are comparable in overall accuracy. The summary area under the receiver operating characteristic curve values was 0.76 for the KCC and 0.78 for MELD scores. The KCC identified patients with AALF who died with 58% sensitivity (95% CI, 51%-65%) and 89% specificity (95% CI, 85%-93%), whereas MELD scores identified patients with AALF who died with 80% sensitivity (95% CI, 74%-86%) and 53% specificity (95% CI, 47%-59%). The KCC predicted hospital mortality in patients with NAALF with 58% sensitivity (95% CI, 54%-63%) and 74% specificity (95% CI, 69%-78%), whereas MELD scores predicted hospital mortality in patients with NAALF with 76% sensitivity (95% CI, 72%-80%) and 73% specificity (95% CI, 69%-78%). In patients with AALF, the KCC's DOR was 10.4 (95% CI, 4.9-22.1) and the MELD score's DOR was 6.6 (95% CI, 2.1-20.2). In patients with NAALF, the KCC's DOR was 4.16 (95% CI, 2.34-7.40) and the MELD score's DOR was 8.42 (95% CI, 5.98-11.88). Based on a meta-analysis of studies, the KCC more accurately predicts hospital mortality among patients with AALF, whereas MELD scores more accurately predict mortality among patients with NAALF. However, there is significant heterogeneity among studies and neither system is optimal for all patients. Given the importance of specificity in decision making for listing for emergency liver transplantation, MELD scores should not replace the KCC in predicting hospital mortality of patients with AALF, but could have a role for NAALF. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.
Larramendi, Carlos H; López-Matas, M Ángeles; Ferrer, Angel; Huertas, Angel Julio; Pagán, Juan Antonio; Navarro, Luis Ángel; García-Abujeta, José Luis; Andreu, Carmen; Carnés, Jerónimo
2013-01-01
Although allergy to Cannabis sativa was first reported over 40 years ago, the allergenicity has scarcely been studied. The objectives of this study were to investigate the frequency of sensitization to this plant, to analyze the clinical characteristics and allergenic profile of sensitized individuals and to identify the allergens involved. Five hundred and forty-five individuals in Spain attending allergy clinics with respiratory or cutaneous symptoms underwent a skin-prick test (SPT) with C. sativa leaf extract. The extract was characterized by SDS-PAGE and 2-dimensional electrophoresis. Specific IgE to C. sativa was measured in positive SPT individuals. The clinical and allergenic profiles of sensitized individuals were investigated and the most-recognized allergens sequenced and characterized by liquid chromatography-mass spectrometry/mass spectrometry. Of this preselected population, 44 individuals had positive SPT to C. sativa (prevalence 8.1%). Prevalence was higher in individuals who were C. sativa smokers (14.6%). Two individuals reported mild symptoms with C. sativa. Twenty-one individuals from 32 available sera (65.6%) had positive specific IgE to C. sativa. Twelve sera recognized at least 6 different bands in a molecular-weight range of between 10 and 60 kDa. Six of them recognized a 10-kDa band, identified as a lipid transfer protein (LTP) and 8 recognized a 38-kDa band, identified as a thaumatin-like protein. There is a high prevalence of sensitization to C. sativa leaves. The clinical symptoms directly attributed to C. sativa were uncommon and mild. The sensitization profile observed suggests that C. sativa sensitization may be mediated by two mechanisms, i.e. cross-reactivity, mainly with LTP and thaumatin-like protein, and exposure-related 'de novo' sensitization. Copyright © 2013 S. Karger AG, Basel.
Barstad, Bjørn; Tveitnes, Dag; Noraas, Sølvi; Selvik Ask, Ingvild; Saeed, Maryam; Bosse, Franziskus; Vigemyr, Grete; Huber, Ilka; Øymar, Knut
2017-12-01
Current markers of Lyme neuroborreliosis (LNB) in children have insufficient sensitivity in the early stage of disease. The B-lymphocyte chemoattractant CXCL13 in the cerebrospinal fluid (CSF) may be useful in diagnosing LNB, but its specificity has not been evaluated in studies including children with clinically relevant differential diagnoses. The aim of this study was to elucidate the diagnostic value of CSF CXCL13 in children with symptoms suggestive of LNB. Children with symptoms suggestive of LNB were included prospectively into predefined groups with a high or low likelihood of LNB based on CSF pleocytosis and the detection of Borrelia antibodies or other causative agents. CSF CXCL13 levels were compared between the groups, and receiver-operating characteristic analyses were performed to indicate optimal cutoff levels to discriminate LNB from non-LNB conditions. Two hundred and ten children were included. Children with confirmed LNB (n=59) and probable LNB (n=18) had higher CSF CXCL13 levels than children with possible LNB (n=7), possible peripheral LNB (n=7), non-Lyme aseptic meningitis (n=12), non-meningitis (n=91) and negative controls (n=16). Using 18 pg/mL as a cutoff level, both the sensitivity and specificity of CSF CXCL13 for LNB (confirmed and probable) were 97%. Comparing only children with LNB and non-Lyme aseptic meningitis, the sensitivity and specificity with the same cutoff level were 97% and 83%, respectively. CSF CXCL13 is a sensitive marker of LNB in children. The specificity to discriminate LNB from non-Lyme aseptic meningitis may be more moderate, suggesting that CSF CXCL13 should be used together with other variables in diagnosing LNB in children.
Malhotra, Chetna; Chan, Angelique; Matchar, David; Seow, Dennis; Chuo, Adeline; Do, Young Kyung
2013-07-01
The Short Portable Mental Status Questionnaire (SPMSQ) is a brief cognitive screening instrument, which is easy to use by a healthcare worker with little training. However, the validity of this instrument has not been established in Singapore. Thus, the primary aim of this study was to determine the diagnostic performance of SPMSQ for screening dementia among patients attending outpatient cognitive assessment clinics and to assess whether the appropriate cut-off score varies by patient's age and education. A secondary aim of the study was to map the SPMSQ scores with Mini-Mental State Examination (MMSE) scores. SPMSQ and MMSE were administered by a trained interviewer to 127 patients visiting outpatient cognitive assessment clinics at the Singapore General Hospital, Changi General Hospital and Tan Tock Seng Hospital. The geriatricians at these clinics then diagnosed these patients with dementia or no dementia (reference standard). Sensitivity and specificity of SPMSQ with different cut-off points (number of errors) were calculated and compared to the reference standard using the Receiver Operator Characteristic (ROC) analysis. Correlation coefficient was also calculated between MMSE and SPMSQ scores. Based on the ROC analysis and a balance of sensitivity and specificity, the appropriate cut-off for SPMSQ was found to be 5 or more errors (sensitivity 78%, specificity 75%). The cut-off varied by education, but not by patient's age. There was a high correlation between SPMSQ and MMSE scores (r = 0.814, P <0.0001). Despite the advantage of being a brief screening instrument for dementia, the use of SPMSQ is limited by its low sensitivity and specificity, especially among patients with less than 6 years of education.
[Diagnostic values of plasma CD64 and sTREM-1 for pediatric pneumonia].
Zhong, Mei-Feng; Zhao, Jian-Mei
2016-07-01
To determine the diagnostic values of plasma CD64 and soluble triggering receptor expressed on myeloid cells-1 (sTREM-1) in children with pneumonia. Sixty children with pneumonia between August 2014 and October 2015 were classified into bacterial pneumonia group (25 cases), viral pneumonia group (17 cases), and Mycoplasma pneumonia group (18 cases) according to their clinical manifestations, pathogen cultures, and X-ray findings. Another 30 healthy children who underwent physical examination during the same period were selected as the control group. The concentrations of CD64 and sTREM-1 in blood samples were determined using ELISA. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic sensitivity and specificity of plasma CD64 and/or sTREM-1 for bacterial pneumonia. The expression of CD64 and sTREM-1 in the bacterial pneumonia group was significantly higher than that in the viral pneumonia, Mycoplasma pneumonia, and control groups (P<0.05). The areas under the ROC curves of CD64, sTREM-1, and a combination of the two markers for diagnosing bacterial pneumonia were 0.878, 0.805, and 0.956, respectively. The sensitivity and specificity of CD64 for diagnosing bacterial pneumonia were 81.30% and 92.32%, respectively, when the cut-off value was 641 pg/mL. The sensitivity and specificity of sTREM-1 for diagnosing bacterial pneumonia were 78.65% and 84.67%, respectively, when the cut-off value was 1 479 pg/mL. The sensitivity and specificity of a combination of the two markers for diagnosing bacterial pneumonia were 93.15% and 91.54%, respectively. Plasma CD64 and sTREM-1 can be used as markers for diagnosing pediatric bacterial pneumonia, and a combination of the two markers results in better diagnosis.
Claus, C; Bergs, S; Emmrich, N C; Hübschen, J M; Mankertz, A; Liebert, U G
2017-02-01
Although teratogenic rubella virus (RV) causes a vaccine-preventable disease, it is still endemic in several countries worldwide. Thus, there is a constant risk of RV importation into non-endemic areas. RV monitoring, especially during measles and Zika virus outbreaks, requires reliable diagnostic tools. For this study, a TaqMan-based one-step reverse transcription-quantitative PCR (RT-qPCR) assay, with the p90 gene as a novel and so far unexplored target for detection of clade I and II genotypes, was developed and evaluated. Automated nucleic acid extraction was carried out. Performance characteristics of the TaqMan RT-qPCR assay were determined for a RV plasmid standard and RNA extracted from virus-infected cell culture supernatants representing clade I and II genotypes. Diagnostic specificity and sensitivity were validated against other RNA and DNA viruses, relevant for RV diagnostic approaches and for RV-positive clinical samples, respectively. The assay is specific and highly sensitive with a limit of detection as low as five to one copies per reaction or 200 infectious virus particles per ml. The coefficients of variation (CV) were specified as intra- (within one run) and inter- (between different runs) assay variation, and calculated based on the standard deviations for the obtained Ct values of the respective samples. Intra- and inter-assay CV values were low, with a maximum of 3.4% and 2.4%, respectively. The assay was shown to be suitable and specific for the analysis of clinical samples. With p90 as a novel target, the highly sensitive and specific TaqMan assay outlined in this study is suitable for RV diagnosis worldwide.
Diagnostic value of cerebrospinal fluid Aβ ratios in preclinical Alzheimer's disease.
Adamczuk, Katarzyna; Schaeverbeke, Jolien; Vanderstichele, Hugo M J; Lilja, Johan; Nelissen, Natalie; Van Laere, Koen; Dupont, Patrick; Hilven, Kelly; Poesen, Koen; Vandenberghe, Rik
2015-12-18
In this study of preclinical Alzheimer's disease (AD) we assessed the added diagnostic value of using cerebrospinal fluid (CSF) Aβ ratios rather than Aβ42 in isolation for detecting individuals who are positive on amyloid positron emission tomography (PET). Thirty-eight community-recruited cognitively intact older adults (mean age 73, range 65-80 years) underwent (18)F-flutemetamol PET and CSF measurement of Aβ1-42, Aβ1-40, Aβ1-38, and total tau (ttau). (18)F-flutemetamol retention was quantified using standardized uptake value ratios in a composite cortical region (SUVRcomp) with reference to cerebellar grey matter. Based on a prior autopsy validation study, the SUVRcomp cut-off was 1.57. Sensitivities, specificities and cut-offs were defined based on receiver operating characteristic analysis with CSF analytes as variables of interest and (18)F-flutemetamol positivity as the classifier. We also determined sensitivities and CSF cut-off values at fixed specificities of 90 % and 95 %. Seven out of 38 subjects (18 %) were positive on amyloid PET. Aβ42/ttau, Aβ42/Aβ40, Aβ42/Aβ38, and Aβ42 had the highest accuracy to identify amyloid-positive subjects (area under the curve (AUC) ≥ 0.908). Aβ40 and Aβ38 had significantly lower discriminative power (AUC = 0.571). When specificity was fixed at 90 % and 95 %, Aβ42/ttau had the highest sensitivity among the different CSF markers (85.71 % and 71.43 %, respectively). Sensitivity of Aβ42 alone was significantly lower under these conditions (57.14 % and 42.86 %, respectively). For the CSF-based definition of preclinical AD, if a high specificity is required, our data support the use of Aβ42/ttau rather than using Aβ42 in isolation.
Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis
Guo, Chuan-Guo; Ji, Rui; Li, Yan-Qing
2015-01-01
Background i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps. Objective Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps. Methods We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy. Results The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively. Conclusions Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%. PMID:25978459
Hädener, Marianne; Martin Fabritius, Marie; König, Stefan; Giroud, Christian; Weinmann, Wolfgang
2017-07-01
Heavy cannabis consumption is considered incompatible with safe driving. In Swiss traffic policy, drivers suspected of regular cannabis use are therefore required to undergo medical assessment of their long-term fitness to drive. A whole blood concentration of the cannabis metabolite 11-nor-9-carboxy-Δ 9 -tetrahydrocannabinol (THCCOOH) of 40 µg/L is currently used by Swiss forensic experts as the decision limit for regular cannabis consumption. The present study aimed to investigate the suitability of THCCOOH-glucuronide blood levels as an additional and/or better marker for the frequency of cannabis use. Whole blood samples collected from 23 heavy (≥10 joints/month) and 25 occasional smokers (≥1 joint/month, but ≤ 1 joint/week) enrolled in a placebo-controlled cannabis smoking study were analyzed for THCCOOH and THCCOOH-glucuronide. Based on receiver operating characteristic (ROC) curve analysis, concentration thresholds could be established for distinguishing between these two groups. Proposed thresholds for heavy use were THCCOOH-glucuronide > 52 µg/L (100% specificity; 41% sensitivity) and/or total THCCOOH > 58 µg/L (100% specificity; 43% sensitivity). Optimum thresholds for occasional use were THCCOOH-glucuronide < 5 µg/L (73% specificity; 97% sensitivity) and/or total THCCOOH < 5 µg/L (62% specificity; 98% sensitivity). Our results indicate that the THCCOOH-glucuronide whole blood concentration is a useful parameter that complements the free THCCOOH level to assess the frequency of cannabis consumption. The consideration of the blood concentrations of both free and glucuronidated THCCOOH improves the identification of heavy users whose fitness to drive has to be carefully assessed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Shen, Yong; Gong, Jiaomei; He, Yanxia; Cheng, Guomei; Okunieff, Paul; Li, Xiaofu
2013-02-01
Human papillomavirus (HPV) infection is the primary cause of cervical cancer. The Quantivirus(®) HPV E6/E7 RNA 3.0 assay (DiaCarta, CA, USA) detects E6/E7 mRNA of 13 high risk subtypes and 6 low risk subtypes. Cervical specimens collected in PreservCyt were processed for HPV detection. Cervical biopsies were taken only from those women with abnormal colposcopy. 200 out of 272 (73.5%) cases were mRNA positive. The percentage of HPV E6/E7 mRNA positive samples increases with the severity of the cytological diagnosis, but not in histological diagnosis. In 146 patients with both tests, the E6/E7 mRNA assay had significant higher positivity rate than the Hybrid Capture 2 assay (75.3% versus 62.3%). The HPV mRNA assay and the HC2 assay had the same sensitivity of high grade cervical intraepithelial neoplasia (CIN 2+), 82.4% (14/17) (95% confidence interval [CI], 64.3, 100). However, the specificity of CIN 2+ for the HPV mRNA assay was significantly lower than HC2 assay. Receiver operating characteristic curve analysis was used to compare the diagnostic performance of the E6/E7 mRNA and HC2. E6/E7 mRNA achieved 58.8% sensitivity with 74.1% specificity, HC2, achieved 47.1% sensitivity with 70.7% specificity. The overall performance of HPV E6/E7 mRNA assay for detecting CIN 2+ was lower than HC2. This study does not support the use of this assay in screening for cervical cancer prevention alone. Copyright © 2012 Elsevier B.V. All rights reserved.
Srihatrai, Parinya; Hlowchitsieng, Thanita
2018-01-01
Purpose: The aim is to evaluate the diagnostic accuracy of digital fundus photography in diabetic retinopathy (DR) screening at a single university hospital. Methods: This was a cross-sectional hospital-based study. One hundred and ninety-eight diabetic patients were recruited for comprehensive eye examination by two ophthalmologists. Five-field fundus photographs were taken with a digital, nonmydriatic fundus camera, and trained primary care physicians then graded the severity of DR present by single-field 45° and five-field fundus photography. Sensitivity and specificity of DR grading were reported using the findings from the ophthalmologists’ examinations as a gold standard. Results: When fundus photographs of the participants’ 363 eyes were analyzed for the presence of DR, there was substantial agreement between the two primary care physicians, κ = 0.6226 for single-field and 0.6939 for five-field photograph interpretation. The sensitivity and specificity of DR detection with single-field photographs were 70.7% (95% Confidence interval [CI]; 60.2%–79.7%) and 99.3% (95% CI; 97.4%–99.9%), respectively. Sensitivity and specificity for five-field photographs were 84.5% (95% CI; 75.8%–91.1%) and 98.6% (95% CI; 96.5%–99.6%), respectively. The receiver operating characteristic was 0.85 (0.80–0.90) for single-field photographs and 0.92 (0.88–0.95) for five-field photographs. Conclusion: The sensitivity and specificity of fundus photographs for DR detection by primary care physicians were acceptable. Single- and five-field digital fundus photography each represent a convenient screening tool with acceptable accuracy. PMID:29283131
Wang, Fen; Chang, Cai; Chen, Min; Gao, Yi; Chen, Ya-Ling; Zhou, Shi-Chong; Li, Jia-Wei; Zhi, Wen-Xiang
2018-03-01
We aimed to investigate the diagnostic performance of shear wave elastography (SWE) combined with conventional ultrasonography (US) for differentiating between benign and malignant thyroid nodules of different sizes. A total of 445 thyroid nodules from 445 patients were divided into 3 groups based on diameter (group 1, ≤ 10 mm; group 2, 10-20 mm; and group 3, > 20 mm). The mean elasticity index of the whole lesion was automatically calculated, and the threshold for differentiation between benign and malignant nodules was constructed by a receiver operating characteristic curve analysis. Diagnostic performances of conventional US and SWE were compared by using pathologic results as reference standards. The mean elasticity was significantly higher in malignant versus benign nodules for all size groups. The differences in mean elasticity in the size groups were not statistically significant for malignant or benign nodules. The specificity of US combined with SWE for group 1 was significantly higher than that for groups 2 and 3 (77.8% versus 62.9% and 53.3%; P < .05), and compared with group 1, the sensitivity was significantly higher for groups 2 and 3 (92.4% and 94.3% versus 80.7%; P < .05). When SWE was added, the specificity increased and the sensitivity and diagnostic accuracy decreased for group 1, and the sensitivity increased and the specificity decreased for groups 2 and 3; however, the differences were not significant. Combined with SWE, US yielded higher specificity for nodules of 10 mm and smaller and higher sensitivity for nodules larger than 10 mm. © 2017 by the American Institute of Ultrasound in Medicine.
Matijasevich, Alicia; Munhoz, Tiago N; Tavares, Beatriz Franck; Barbosa, Ana Paula Pereira Neto; da Silva, Diego Mello; Abitante, Morgana Sonza; Dall'Agnol, Tatiane Abreu; Santos, Iná S
2014-10-08
Standardized questionnaires designed for the identification of depression are useful for monitoring individual as well as population mental health. The Edinburgh Postnatal Depression Scale (EPDS) has originally been developed to assist primary care health professionals to detect postnatal depression, but several authors recommend its use outside of the postpartum period. In Brazil, the use of the EPDS for screening depression outside the postpartum period and among non-selected populations has not been validated. The present study aimed to assess the validity of the EPDS as a screening instrument for major depressive episode (MDE) among adults from the general population. This is a validation study that used a population-based sampling technique to select the participants. The study was conducted in the city of Pelotas, Brazil. Households were randomly selected by two stage conglomerates with probability proportional to size. EPDS was administered to 447 adults (≥20 years). Approximately 17 days later, participants were reinterviewed by psychiatrics and psychologists using a structured diagnostic interview (Mini International Neuropsychiatric Interview, MINI). We calculated the sensitivity and specificity of each cutoff point of EPDS, and values were plotted as a receiver operator characteristic curve. The best cutoff point for screening depression was ≥8, with 80.0% (64.4 - 90.9%) sensitivity and 87.0% (83.3 - 90.1%) specificity. Among women the best cutoff point was ≥8 too with values of sensitivity and specificity of 84.4% (67.2 - 94.7%) and 81.3% (75.5 - 86.1%), respectively. Among men, the best cutoff point was ≥7 (75% sensitivity and 89% specificity). The EPDS was shown to be suitable for screening MDE among adults in the community.
Uysal-Cantürk, P; Hanağası, H A; Bilgiç, B; Gürvit, H; Emre, M
2018-01-01
Cognitive impairment is one of the most disabling non-motor symptoms of Parkinson's disease. Mild cognitive impairment constitutes a major risk for the development of Parkinson's disease dementia in the course of the disease. A Movement Disorder Society Task Force proposed diagnostic criteria for mild cognitive impairment in Parkinson's disease (PD-MCI), comprising two operational levels: Level I and Level II. The objective of our study was to test the accuracy of Level I versus Level II diagnostic criteria. Eighty-six consecutive patients with Parkinson's disease were screened and 68 patients without dementia or depression were included in the study. We used the Montreal Cognitive Assessment, Mini-Mental State Examination and Addenbrooke's Cognitive Evaluation-R screening tools for Level I and an extensive neuropsychological battery for Level II assessment. We first diagnosed PD-MCI on the basis of Level II assessment and then calculated sensitivity, specificity and area under the receiver-operator characteristics curve, comparing the performance of the three screening batteries. None of the three screening batteries proposed for Level I assessment provided satisfactory combined sensitivity and specificity for detecting PD-MCI, and their performance was similar. Using the Level II criteria, 29 patients (43%) were diagnosed as having PD-MCI. Lowest cut-off levels that provided at least 80% sensitivity were 24 for the Montreal Cognitive Assessment, 29 for the Mini-Mental State Examination and 87 for the Addenbrooke's Cognitive Evaluation-R. However, specificity levels were below 80% at these cut-off levels. We conclude that Level I assessment alone using screening batteries is not sufficiently sensitive/specific to detect PD-MCI. © 2017 EAN.
Serum interleukin measurement may help identify thyroid cancer patients with active disease.
Martins, Mariana Bonjiorno; Marcello, Marjory Alana; Batista, Fernando de Assis; Peres, Karina Colombera; Meneghetti, Murilo; Ward, Mirela Andrea Latham; Etchebehere, Elba Cristina Sá de Camargo; da Assumpção, Ligia Vera Montali; Ward, Laura Sterian
2018-02-01
Investigate the clinical utility of serum interleukin dosages of IL-2, IL-2R, IL-4, IL-6, IL-6R, IL-8, IL-10 and IL-12 in the diagnosis and characterization of patients with DTC. In particular, verify ILs utility in the identification of individuals who are evolving disease-free or with the active disease. We evaluated 200 patients with malignant nodules (100 patients disease-free and 100 patients with recurrence/active disease); 60 benign nodules and 100 healthy controls, serum levels were assessed by ELISA. All ILs, but not IL-4, differentiated these three groups. We observed that IL-2, 2R and 10 serum concentrations were associated with thyroglobulin levels. Serum IL-2 was able to differentiate patients with active disease from the disease-free with a sensitivity of 98%, specificity of 58%, positive predictive value (PPV) of 70% and negative predictive value (NPV) of 97% (p=0.0007). IL-6R levels differentiated patients with active disease from the disease-free patients with 56% sensitivity, 63% specificity, PPV of 60% and NPV of 59% (p<0.0001). IL-8 values also distinguished patients with active disease from the disease-free ones with sensitivity of 50%, specificity of 76%, PPV of 68% and NPV of 60% (p=0.0025); using IL-12, we obtained a sensitivity value of 73%, specificity of 66%, PPV of 68% and NPV of 71% (p<0.0001). Furthermore, interleukin levels showed association with some tumor characteristics of aggressiveness. We suggest that the serum concentration of ILs may assist in the diagnosis and characterization of tumor malignancy helping identify patients with active disease who deserve closer medical attention. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F
2011-01-01
Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365
Gold, A J; Langlois, D K; Refsal, K R
2016-11-01
Previous studies that included limited numbers of affected dogs have suggested basal cortisol concentrations ≤55 nmol/L (2 μg/dL) are sensitive, but nonspecific, for a diagnosis of hypoadrenocorticism. A detailed assessment of the diagnostic utility of basal cortisol concentrations is warranted. To evaluate the utility of basal cortisol concentrations for the diagnosis of hypoadrenocorticism in a large number of dogs, including those with and without serum electrolyte abnormalities. Five hundred and twenty-two dogs, including 163 dogs with hypoadrenocorticism, 351 dogs with nonadrenal gland illness, and 8 dogs with equivocal results. Retrospective study. Basal and post-ACTH cortisol concentrations and sodium and potassium concentrations were collected from medical records. A receiver operating characteristic (ROC) curve was constructed for basal cortisol concentrations by standard methodologies. Sensitivity, specificity, and predictive values were determined for various cut-points. The area under the ROC curve was 0.988 and was similarly excellent regardless of serum electrolyte concentrations. At the most discriminatory cut-point of 22 nmol/L (0.8 μg/dL), sensitivity and specificity were 96.9 and 95.7%, respectively. A basal cortisol concentration of ≤55 nmol/L (2 μg/dL) resulted in a sensitivity of 99.4%. Conversely, a basal cortisol concentration of ≤5.5 nmol/L (0.19 μg/dL) resulted in a specificity of 99.1%. Similar to findings in previous studies, basal cortisol concentrations >55 nmol/L (2 μg/dL) are useful in excluding a diagnosis of hypoadrenocorticism. Interestingly, excellent specificities and positive predictive values were observed at lower cut-point cortisol concentrations. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
Brief Report: Validation of a Definition of Flare in Patients With Established Gout.
Gaffo, Angelo L; Dalbeth, Nicola; Saag, Kenneth G; Singh, Jasvinder A; Rahn, Elizabeth J; Mudano, Amy S; Chen, Yi-Hsing; Lin, Ching-Tsai; Bourke, Sandra; Louthrenoo, Worawit; Vazquez-Mellado, Janitzia; Hernández-Llinas, Hansel; Neogi, Tuhina; Vargas-Santos, Ana Beatriz; da Rocha Castelar-Pinheiro, Geraldo; Amorim, Rodrigo B C; Uhlig, Till; Hammer, Hilde B; Eliseev, Maxim; Perez-Ruiz, Fernando; Cavagna, Lorenzo; McCarthy, Geraldine M; Stamp, Lisa K; Gerritsen, Martijn; Fana, Viktoria; Sivera, Francisca; Taylor, William
2018-03-01
To perform external validation of a provisional definition of disease flare in patients with gout. Five hundred nine patients with gout were enrolled in a cross-sectional study during a routine clinical care visit at 17 international sites. Data were collected to classify patients as experiencing or not experiencing a gout flare, according to a provisional definition. A local expert rheumatologist performed the final independent adjudication of gout flare status. Sensitivity, specificity, predictive values, and receiver operating characteristic (ROC) curves were used to determine the diagnostic performance of gout flare definitions. The mean ± SD age of the patients was 57.5 ± 13.9 years, and 89% were male. The definition requiring fulfillment of at least 3 of 4 criteria (patient-defined gout flare, pain at rest score of >3 on a 0-10-point numerical rating scale, presence of at least 1 swollen joint, and presence of at least 1 warm joint) was 85% sensitive and 95% specific in confirming the presence of a gout flare, with an accuracy of 92%. The ROC area under the curve was 0.97. The definition based on a classification and regression tree algorithm (entry point, pain at rest score >3, followed by patient-defined flare "yes") was 73% sensitive and 96% specific. The definition of gout flare that requires fulfillment of at least 3 of 4 patient-reported criteria is now validated to be sensitive, specific, and accurate for gout flares, as demonstrated using an independent large international patient sample. The availability of a validated gout flare definition will improve the ascertainment of an important clinical outcome in studies of gout. © 2017, American College of Rheumatology.
Kikuchi, Ken; Shigihara, Takeshi; Hashimoto, Yuko; Miyajima, Masayuki; Haga, Nobuhiro; Kojima, Yoshiyuki; Shishido, Fumio
2017-01-01
Abstract AIMS: To evaluate the relationship between the apparent diffusion coefficient (ADC) value for bladder cancer and the recurrence/progression risk of post-transurethral resection (TUR). METHODS: Forty-one patients with initial and non-muscle-invasive bladder cancer underwent MRI from 2009 to 2012. Two radiologists measured ADC values. A pathologist calculated the recurrence/progression scores, and risk was classified based on the scores. Pearson’s correlation was used to analyze the correlations of ADC value with each score and with each risk group, and the optimal cut-off value was established based on receiver operating characteristic (ROC) curve analysis. Furthermore, the relationship between actual recurrence / progression of cases and ADC values was examined by Unpaird U test. RESULTS: There were significant correlations between ADC value and the recurrence score as well as the progression score (P<0.01, P<0.01, respectively). There were also significant correlations between ADC value and the recurrence risk group as well as progression risk group (P=0.042, P<0.01, respectively). The ADC cut-off value on ROC analysis was 1.365 (sensitivity 100%; specificity 97.4%) for the low and intermediate recurrence risk groups, 1.024 (sensitivity 47.4%; specificity 100%) for the intermediate and high recurrence risk groups, 1.252 (sensitivity 83.3%; specificity 81.3%) for the low and intermediate progression risk groups, and 0.955 (sensitivity 87.5%; specificity 63.2%) between the intermediate and high progression risk groups. The difference between the ADC values of the recurrence and nonrecurrence group in Unpaired t test was significant (P<0.05). CONCLUSION: ADC on MRI in bladder cancer could potentially be useful, non-invasive measurement for estimating the risks of recurrence and progression. PMID:28680010
Keezer, Mark R; Bouma, Hanni K; Wolfson, Christina
2014-11-01
To describe the diagnostic accuracy of screening questionnaires to identify epilepsy in adults, we performed a systematic review of diagnostic studies that assessed the sensitivity and specificity of such screening questionnaires as compared to a physician's clinical assessment. We searched Ovid MEDLINE (1946 to present) and Ovid EMBASE (1947 to present) for studies that estimated the sensitivity and specificity of nonphysician administered screening questionnaires for adults with epilepsy. Both telephone and in-person administered questionnaires were included, whether applied to population or hospital/clinic-based cohorts. The risk of bias was assessed using the Quality Assessment of Diagnostic Studies-2 (QUADAS-2) tool. Our initial search strategy resulted in 917 records. We found nine studies eligible for inclusion. The estimated sensitivity and specificity of the questionnaires used to identify persons with a lifetime history of epilepsy ranged from 81.5% to 100% and 65.6% to 99.2%, respectively. The sensitivity and specificity of these questionnaires in identifying persons with active epilepsy ranged from 48.6% to 100% and 73.9% to 99.9%, respectively. Overall we found a high risk of bias in patient selection and study flow in the majority of studies. We identified nine validation studies of epilepsy screening questionnaires, summarized their study characteristics, presented their results, and performed a rigorous quality assessment. This review serves as a basis for future studies by providing a systematic review of existing work. Future research addressing previous limitations will ultimately allow us to more accurately estimate the burden and risk of epilepsy in the general population. Wiley Periodicals, Inc. © 2014 International League Against Epilepsy.
Le, Tham; O’Brien, Katherine L.; Murdoch, David R.; Prosperi, Christine; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Kotloff, Karen L.; Levine, Orin S.; Scott, J. Anthony G.; Thea, Donald M.; Awori, Juliet O.; Baillie, Vicky L.; Cascio, Stephanie; Chuananon, Somchai; DeLuca, Andrea N.; Driscoll, Amanda J.; Ebruke, Bernard E.; Endtz, Hubert P.; Kaewpan, Anek; Kahn, Geoff; Karani, Angela; Karron, Ruth A.; Moore, David P.; Park, Daniel E.; Rahman, Mohammed Ziaur; Salaudeen, Rasheed; Seidenberg, Phil; Somwe, Somwe Wa; Sylla, Mamadou; Tapia, Milagritos D.; Zeger, Scott L.; Deloria Knoll, Maria; Madhi, Shabir A.; O’Brien, Katherine L.; Levine, Orin S.; Knoll, Maria Deloria; Feikin, Daniel R.; DeLuca, Andrea N.; Driscoll, Amanda J.; Fancourt, Nicholas; Fu, Wei; Hammitt, Laura L.; Higdon, Melissa M.; Kagucia, E. Wangeci; Karron, Ruth A.; Li, Mengying; Park, Daniel E.; Prosperi, Christine; Wu, Zhenke; Zeger, Scott L.; Watson, Nora L.; Crawley, Jane; Murdoch, David R.; Brooks, W. Abdullah; Endtz, Hubert P.; Zaman, Khalequ; Goswami, Doli; Hossain, Lokman; Jahan, Yasmin; Ashraf, Hasan; Howie, Stephen R. C.; Ebruke, Bernard E.; Antonio, Martin; McLellan, Jessica; Machuka, Eunice; Shamsul, Arifin; Zaman, Syed M.A.; Mackenzie, Grant; Scott, J. Anthony G.; Awori, Juliet O.; Morpeth, Susan C.; Kamau, Alice; Kazungu, Sidi; Ominde, Micah Silaba; Kotloff, Karen L.; Tapia, Milagritos D.; Sow, Samba O.; Sylla, Mamadou; Tamboura, Boubou; Onwuchekwa, Uma; Kourouma, Nana; Toure, Aliou; Madhi, Shabir A.; Moore, David P.; Adrian, Peter V.; Baillie, Vicky L.; Kuwanda, Locadiah; Mudau, Azwifarwi; Groome, Michelle J.; Mahomed, Nasreen; Baggett, Henry C.; Thamthitiwat, Somsak; Maloney, Susan A.; Bunthi, Charatdao; Rhodes, Julia; Sawatwong, Pongpun; Akarasewi, Pasakorn; Thea, Donald M.; Mwananyanda, Lawrence; Chipeta, James; Seidenberg, Phil; Mwansa, James; Wa Somwe, Somwe; Kwenda, Geoffrey; Anderson, Trevor P.; Mitchell, Joanne
2017-01-01
Abstract Background. Lack of a gold standard for identifying bacterial and viral etiologies of pneumonia has limited evaluation of C-reactive protein (CRP) for identifying bacterial pneumonia. We evaluated the sensitivity and specificity of CRP for identifying bacterial vs respiratory syncytial virus (RSV) pneumonia in the Pneumonia Etiology Research for Child Health (PERCH) multicenter case-control study. Methods. We measured serum CRP levels in cases with World Health Organization–defined severe or very severe pneumonia and a subset of community controls. We evaluated the sensitivity and specificity of elevated CRP for “confirmed” bacterial pneumonia (positive blood culture or positive lung aspirate or pleural fluid culture or polymerase chain reaction [PCR]) compared to “RSV pneumonia” (nasopharyngeal/oropharyngeal or induced sputum PCR-positive without confirmed/suspected bacterial pneumonia). Receiver operating characteristic (ROC) curves were constructed to assess the performance of elevated CRP in distinguishing these cases. Results. Among 601 human immunodeficiency virus (HIV)–negative tested controls, 3% had CRP ≥40 mg/L. Among 119 HIV-negative cases with confirmed bacterial pneumonia, 77% had CRP ≥40 mg/L compared with 17% of 556 RSV pneumonia cases. The ROC analysis produced an area under the curve of 0.87, indicating very good discrimination; a cut-point of 37.1 mg/L best discriminated confirmed bacterial pneumonia (sensitivity 77%) from RSV pneumonia (specificity 82%). CRP ≥100 mg/L substantially improved specificity over CRP ≥40 mg/L, though at a loss to sensitivity. Conclusions. Elevated CRP was positively associated with confirmed bacterial pneumonia and negatively associated with RSV pneumonia in PERCH. CRP may be useful for distinguishing bacterial from RSV-associated pneumonia, although its role in discriminating against other respiratory viral-associated pneumonia needs further study. PMID:28575375
Kurtoğlu, Selim; Hatipoğlu, Nihal; Mazıcıoğlu, Mümtaz; Kendirici, Mustafa; Keskin, Mehmet; Kondolot, Meda
2010-01-01
Childhood obesity is associated with an increased risk for insulin resistance. The underlying mechanism for the physiological increase in insulin levels in puberty is not clearly understood. The aim of the present study was to determine the cut-off values for homeostasis model assessment for insulin resistance (HOMA-IR) in obese children and adolescents according to gender and pubertal status. Two hundred and eight obese children and adolescents (141 girls, 127 boys) aged between 5 and 18 years were included in the study. The children were divided into prepubertal and pubertal groups. A standard oral glucose tolerance test (OGTT) was carried out in all children. A total insulin level exceeding 300 μU/mL in the blood samples, collected during the test period, was taken as the insulin resistance criterion. Cut-off values for HOMA-IR were calculated by receiver operating characteristic (ROC) analysis. In the prepubertal period, the rate of insulin resistance was found to be 37% in boys and 27.8% in girls,while in the pubertal period, this rate was 61.7% in boys and 66.7% in girls. HOMA-IR cut-off values for insulin resistance in the prepubertal period were calculated to be 2.67 (sensitivity 88.2%, specificity 65.5%) in boys and 2.22 (sensitivity 100%, specificity 42.3%) in girls, and in the pubertal period, they were 5.22 (sensitivity 56%, specificity 93.3%) in boys and 3.82 (sensitivity 77.1%, specificity 71.4%) in girls. Since gender, obesity and pubertal status are factors affecting insulin resistance, cut-off values which depend on gender and pubertal status, should be used in evaluation of insulin resistance.
Koizumi, N; Harada, Y; Beika, M; Minamikawa, T; Yamaoka, Y; Dai, P; Murayama, Y; Yanagisawa, A; Otsuji, E; Tanaka, H; Takamatsu, T
2016-08-01
The establishment of a precise and rapid method to detect metastatic lymph nodes (LNs) is essential to perform less invasive surgery with reduced gastrectomy along with reduced lymph node dissection. We herein describe a novel imaging strategy to detect 5-aminolevulinic acid (5-ALA)-induced protoporphyrin IX (PpIX) fluorescence in excised LNs specifically with reduced effects of tissue autofluorescence based on photo-oxidation of PpIX. We applied the method in a clinical setting, and evaluated its feasibility. To reduce the unfavorable effect of autofluorescence, we focused on photo-oxidation of PpIX: Following light irradiation, PpIX changes into another substance, photo-protoporphyrin, via an oxidative process, which has a different spectral peak, at 675 nm, whereas PpIX has its spectral peak at 635 nm. Based on the unique spectral alteration, fluorescence spectral imaging before and after light irradiation and subsequent originally-developed image processing was performed. Following in vitro study, we applied this method to a total of 662 excised LNs obtained from 30 gastric cancer patients administered 5-ALA preoperatively. Specific visualization of PpIX was achieved in in vitro study. The method allowed highly sensitive detection of metastatic LNs, with sensitivity of 91.9% and specificity of 90.8% in the in vivo clinical trial. Receiver operating characteristic analysis indicated high diagnostic accuracy, with the area under the curve of 0.926. We established a highly sensitive and specific 5-ALA-induced fluorescence imaging method applicable in clinical settings. The novel method has a potential to become a useful tool for intraoperative rapid diagnosis of LN metastasis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Noble, Fergus; Curtis, Nathan; Harris, Scott; Kelly, Jamie J; Bailey, Ian S; Byrne, James P; Underwood, Timothy J
2012-06-01
Oesophagectomy is associated with significant morbidity and mortality. A simple score to define a patient's risk of developing major complications would be beneficial. Patients who underwent upper gastrointestinal resections with an oesophageal anastomosis between 2005 and 2010 were reviewed and formed the development dataset with resections performed in 2011 forming a prospective validation dataset. The association between post-operative C-reactive protein (CRP), white cell count (WCC) and albumin levels with anastomotic leak (AL) or major complication including death using the Clavien-Dindo (CD) classification were analysed by receiver operating characteristic curves. After multivariate analysis, from the development dataset, these factors were combined to create a novel score which was subsequently tested on the validation dataset. Two hundred fifty-eight patients were assessed to develop the score. Sixty-three patients (25%) developed a major complication, and there were seven (2.7%) in-patient deaths. Twenty-six (10%) patients were diagnosed with AL at median post-operative day 7 (range: 5-15). CRP (p = 0.002), WCC (p < 0.0001) and albumin (p = 0.001) were predictors of AL. Combining these markers improved prediction of AL (NUn score > 10: sensitivity 95%, specificity 49%, diagnostic accuracy 0.801 (95% confidence interval: 0.692-0.909, p < 0.0001)). The validation dataset confirmed these findings (NUn score > 10: sensitivity 100%, specificity 57%, diagnostic accuracy 0.879 (95% CI 0.763-0.994, p = 0.014)) and a major complication or death (NUn > 10: sensitivity 89%, specificity 63%, diagnostic accuracy 0.856 (95% CI 0.709-1, p = 0.001)). Blood-borne markers of the systemic inflammatory response are predictors of AL and major complications after oesophageal resection. When combined they may categorise a patient's risk of developing a serious complication with higher sensitivity and specificity.
Mokhtarian, Kobra; Meamar, Ahmad Reza; Khoshmirsafa, Majid; Razmjou, Elham; Masoori, Leila; Khanmohammadi, Majid; Akhlaghi, Lame; Falak, Reza
2018-01-01
Laboratory diagnosis of sheep fasciolosis is commonly performed by coprological examinations; however, this method may lead to false negative results during the acute phase of the infection. Furthermore, the poor sensitivity of coprological methods is considered to be a paradox in the chronic phase of the infection. In this study, we compared the immunoreactivity of native and recombinant forms of Fasciola hepatica excretory/secretory antigens and determined their capabilities for the development of F. hepatica-specific immunoassays. Immunoreactivity and specificity of recombinant and native forms of F. hepatica antigens, including fatty acid binding protein (FABP), glutathione-S-transferase (GST), and cathepsin L-1 (CL1), in parallel with native forms of FABP and GST, were studied for serodiagnosis of the chronic form of sheep fasciolosis, individually or in combination with each other by enzyme-linked immunosorbent assays (ELISA). The correlation of the findings was assessed by receiver-operator characteristic (ROC); furthermore, the specificity and sensitivity were assessed by Youden's J. Serologic cross-reactivity was evaluated using samples from healthy sheep (n = 40), Fasciola-infected sheep (n = 30), and sheep with other parasitic infections (n = 43). The FABPs were determined to be greater than 95% sensitive for F. hepatica serodiagnosis. The most desirable diagnostic recombinant antigen was rCL1, which showed 100% sensitivity and 97% specificity in ELISA and was capable of discriminating the positive and negative samples by maximum Youden's J results. We conclude that rCL1 can be used for routine serodiagnosis of chronic fasciolosis. Thus, it could be advantageous in development of immunoassays for screening of ovine herds in fasciolosis-endemic areas and as a reliable agent for detection of fasciolosis in non-endemic regions.
Forkmann, Thomas; Vehren, Thomas; Boecker, Maren; Norra, Christine; Wirtz, Markus; Gauggel, Siegfried
2009-10-01
The Beck Depression Inventory (BDI) is widely used for depression screening in various patient populations. However, there are still insufficient data about its sensitivity and specificity in nonpsychiatric patients. Furthermore, some research suggests that somatic BDI items heighten its sum score artificially in physically ill patients. The aim of the present study was to validate the conventional BDI cut-off score by examination of its sensitivity and specificity in a mixed sample of cardiac inpatients and compare it to a modified "cognitive-emotional" BDI (BDI(c/e)) after exclusion of somatic items. A total of 126 cardiologic inpatients were assessed. Receiver operating characteristic curves (ROC) were calculated for total BDI (BDI(t)) and BDI(c/e). Screening performance of cut-off scores was evaluated using the Youden Index (Y). With the application of the conventional BDI cut-off score, ROC analysis revealed a moderate overall screening performance with Y=52.6 and an area under the curve (AUC) of 0.83. In contrast, Y improved to 57.5 at a cut-off score of >9, but screening performance was still not optimal. BDI(c/e) showed also a moderate screening performance (AUC=.82); Y was maximized at a cut-off score of >8 (Y=0.53.5). Again, no cut-off score provided optimal screening performance. The BDI cannot be recommended as a formal screening instrument in cardiac inpatients since no cut-off score for either BDI(t) or BDI(c/e) combined both sufficiently high sensitivity and specificity. However, the shorter BDI(c/e) could be used as alternative to BDI(t) which may be confounded in physically ill patients. Generally, researchers should consider using alternative screening instruments (e.g., the Hospital Anxiety and Depression Scale) instead.